SIMATIC. ET 200SP BusAdapter. Preface 1. Guide. Product overview. BusAdapter BA 2xRJ45 4. BusAdapter BA 2xFC 5. BusAdapter BA 2xSCRJ 6.

Size: px
Start display at page:

Download "SIMATIC. ET 200SP BusAdapter. Preface 1. Guide. Product overview. BusAdapter BA 2xRJ45 4. BusAdapter BA 2xFC 5. BusAdapter BA 2xSCRJ 6."

Transcription

1 Siemens Controls

2 Preface 1 Guide 2 SIMATIC ET 200SP BusAdapter Manual Product overview 3 BusAdapter BA 2xRJ45 4 BusAdapter BA 2xFC 5 BusAdapter BA 2xSCRJ 6 BusAdapter BA SCRJ/RJ45 7 BusAdapter BA SCRJ/FC 8 BusAdapter BA 2xLC 9 BusAdapter BA LC/RJ45 10 BusAdapter BA LC/FC 11 Strain relief 12 A Dimension drawings B Accessories 03/2018 A5E AA

3 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens Controls A5E AA P 02/2018 Subject to change Siemens AG Division Digital Factory Postfach NÜRNBERG GERMANY Copyright Siemens AG All rights reserved

4 Table of contents 1 Preface Guide BusAdapter guide Product overview BusAdapter BA 2xRJ Product overview Connecting Diagnostics Technical specifications BusAdapter BA 2xFC Product overview Connecting Diagnostics Technical specifications BusAdapter BA 2xSCRJ Product overview Connecting Diagnostics Technical specifications BusAdapter BA SCRJ/RJ Product overview Connecting Diagnostics Technical specifications BusAdapter BA SCRJ/FC Product overview Connecting Diagnostics Technical specifications BusAdapter Manual, 03/2018, A5E AA 3

5 Table of contents 9 BusAdapter BA 2xLC Product overview Connecting Diagnostics Technical specifications BusAdapter BA LC/RJ Product overview Connecting Diagnostics Technical specifications BusAdapter BA LC/FC Product overview Connecting Diagnostics Technical specifications Strain relief Product overview Installing A Dimension drawings A.1 BusAdapter dimension drawings A.2 Strain relief dimension drawings B Accessories B.1 Accessories Siemens Controls BusAdapter 4 Manual, 03/2018, A5E AA

6 Preface 1 Purpose of the manual This manual provides all the necessary information for configuring, installing, connecting and commissioning the BusAdapter. Basic knowledge required The following knowledge is required in order to understand the manual: General knowledge in the field of automation technology Knowledge of the use of computers or PC -like tools (e.g. programming devices) under the Windows operating system. Knowledge of working with STEP 7. You can find information on this topic in the STEP 7 online help. Range of validity of this manual The manual describes the components based on the data valid at the time of its release. We reserve the right to include up-to-date Product Information with new components and new versions of components. BusAdapter Manual, 03/2018, A5E AA 5

7 Preface Recycling and disposal The BusAdapter can be recycled due to their low pollutant content. For environmentally sustainable recycling and disposal of your old device, please contact a company certified for the disposal of electronic waste. Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens' products and solutions constitute one element of such a concept. Customers are responsible for preventing unauthorized access to their plants, systems, machines and networks. Such systems, machines and components should only be connected to an enterprise network or the internet if and to the extent such a connection is necessary and only when appropriate security measures (e.g. firewalls and/or network segmentation) are in place. For additional information on industrial security measures that may be implemented, please visit ( Siemens' products and solutions undergo continuous development to make them more secure. Siemens strongly recommends that product updates are applied as soon as they are available and that the latest product versions are used. Use of product versions that are no longer supported, and failure to apply the latest updates may increase customers' exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under ( Siemens Controls BusAdapter 6 Manual, 03/2018, A5E AA

8 Preface Siemens Industry Online Support You can find current information on the following topics quickly and easily here: Product support All the information and extensive know-how on your product, technical specifications, FAQs, certificates, downloads, and manuals. Application examples Tools and examples to solve your automation tasks as well as function blocks, performance information and videos. Services Information about Industry Services, Field Services, Technical Support, spare parts and training offers. Forums For answers and solutions concerning automation technology. mysupport Your personal work area in Industry Online Support for messages, support queries, and configurable documents. This information is provided by the Siemens Industry Online Support on the Internet ( Industry Mall The Industry Mall is the catalog and order system of Siemens AG for automation and drive solutions on the basis of Totally Integrated Automation (TIA) and Totally Integrated Power (TIP). You can find catalogs for all automation and drive products on the Internet ( BusAdapter Manual, 03/2018, A5E AA 7

9 Guide BusAdapter guide Device information The BusAdapter manual contains information, for example, on properties, assembling, connecting, configuring and parameter assignment, alarms and diagnostics and technical specifications of the BusAdapter. General information The function manuals contain detailed descriptions on general topics such as PROFINET and communication. You can download the documentation free of charge from the Internet ( "mysupport" With "mysupport", your personal work area, you make the most of your Industry Online Support. In "mysupport" you can store filters, favorites and tags, request CAx data and put together your personal library in the Documentation area. Furthermore, your data is automatically filled into support requests and you always have an overview of your current requests. You must register once to use the full functionality of "mysupport". You can find "mysupport" on the Internet ( Siemens Controls BusAdapter 8 Manual, 03/2018, A5E AA

10 Guide 2.1 BusAdapter guide "mysupport" - Documentation In the Documentation area of "mysupport", you have the possibility to combine complete manuals or parts of them to make your own manual. You can export the manual in PDF format or in an editable format. Your documentation is available in My Documentation Manager ( "mysupport" - CAx data In the CAx data area in "mysupport", you can access the current product data for your CAx or CAe system. You configure your own download package with a few clicks. In doing so you can select: Product images, 2D dimension drawings, 3D models, internal circuit diagrams, EPLAN macro files Manuals, characteristics, operating manuals, certificates Product master data You can find "mysupport" - CAx data on the Internet ( Application examples The application examples support you with various tools and examples for solving your automation tasks. Solutions are shown in interplay with multiple components in the system - separated from the focus on individual products. Additional information can be found on the Internet under Application examples ( BusAdapter Manual, 03/2018, A5E AA 9

11 Guide 2.1 BusAdapter guide SIMATIC Automation Tool You can use the SIMATIC Automation Tool to perform commissioning and maintenance activities simultaneously on various SIMATIC S7 stations as a bulk operation independent of the TIA Portal. The SIMATIC Automation Tool provides a multitude of functions: Scanning of a PROFINET/Ethernet system network and identification of all connected CPUs Address assignment (IP, subnet, gateway) and station name (PROFINET device) to a CPU Transfer of the date and the programming device/pc time converted to UTC time to the module Program download to CPU RUN/STOP mode switchover CPU localization by means of LED flashing Reading out of CPU error information Reading of the CPU diagnostic buffer Reset to factory settings Firmware update of the CPU and connected modules You can find the SIMATIC Automation Tool on the Internet ( PRONETA With SIEMENS PRONETA (PROFINET network analysis), you analyze the plant network during commissioning. PRONETA features two core functions: The topology overview independently scans PROFINET and all connected components. PRONETA also scans: configuration of the station name, IP subnet mask and identification and maintenance data (I&M1..3) For more information, refer to SIEMENS PRONETA ( Siemens Controls BusAdapter 10 Manual, 03/2018, A5E AA

12 Product overview 3 Introduction The SIMATIC BusAdapters connect PROFINET IO to their ET 200SP system. You select the required connection technology and connection method for your process from the different versions of SIMATIC BusAdapter. Supported PROFINET devices The SIMATIC BusAdapters are used for: ET 200SP interface module and central processing unit (CPU and Open Controller) PN/PN Coupler Switches Overview The SIMATIC BusAdapters can be ordered in the following versions: BusAdapter Article number Property Figure BA 2xRJ45 6ES7193-6AR00-0AA0 PROFINET BusAdapter with standard Ethernet socket for standard RJ45 connector BA 2xFC 6ES7193-6AF00-0AA0 PROFINET BusAdapter with FastConnect Ethernet connection for direct connection of the bus cable for applications with increased EMC and vibration/shock load BusAdapter Manual, 03/2018, A5E AA 11

13 Product overview BusAdapter Article number Property Figure BA 2xSCRJ 6ES7193-6AP00-0AA0 PROFINET BusAdapter with fiberoptic cable connection POF/PCF for SCRJ connector for applications with increased EMC and vibration/shock load as well as electrical potential differences between two stations BA SCRJ/RJ45 6ES7193-6AP20-0AA0 Media converter, PROFINET BusAdapter with POF/PCF fiberoptic cable standard RJ45 connector BA SCRJ/FC 6ES AP40-0AA0 Media converter, PROFINET BusAdapter with POF/PCF fiberoptic cable direct connection of bus cable BA 2xLC 6ES7193-6AG00-0AA0 PROFINET BusAdapter with glass fiber-optic cable connection for LC connector for applications with increased EMC and vibration/shock load as well as electrical potential differences between two stations Siemens Controls BusAdapter 12 Manual, 03/2018, A5E AA

14 Product overview BusAdapter Article number Property Figure BA LC/RJ45 6ES7193-6AG20-0AA0 Media converter, PROFINET BusAdapter with glass fiber-optic cable standard RJ45 connector BA LC/FC 6ES7193-6AG40-0AA0 Media converter, PROFINET BusAdapter with glass fiber-optic cable direct connection of bus cable See also Strain relief (Page 64) BusAdapter Manual, 03/2018, A5E AA 13

15 BusAdapter BA 2xRJ Product overview Article number 6ES7193-6AR00-0AA0 View Figure 4-1 BusAdapter BA 2 RJ45 Properties You connect PROFINET IO cable with RJ45 connector to the PROFINET device via the BusAdapter BA 2 RJ45. To do this, screw the BusAdapter BA 2 RJ45 to the PROFINET device and insert the PROFINET connecting cable. You loop through the PROFINET via the integrated 2-port switch. Siemens Controls BusAdapter 14 Manual, 03/2018, A5E AA

16 BusAdapter BA 2xRJ Connecting 4.2 Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide ( Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required Connector: IE FC RJ45 plug 180 2X2 (6GK1901-1BB10-2A) IE FC RJ45 plug 180 4X2 (6GK1901-1BB12-2A) Cables: IE FC TP standard cable (6XV1840-2A) IE FC TP trailing cable (6XV1840-3AH10) IE FC TP marine cable (6XV1840-4AH10) IE FC TP robust cable (6XV1841-2) IE TP torsion cable (6XV1870-2F) Please observe the specifications in the PROFINET Installation Guide ( BusAdapter Manual, 03/2018, A5E AA 15

17 BusAdapter BA 2xRJ Connecting Pin assignment The following table shows the signal name and description of the pin assignment of BusAdapter BA 2 RJ45. Table 4-1 PROFINET IO pin assignment with BusAdapter BA 2 RJ45 View Signal name Description 1 TD Transmit Data + 2 TD_N Transmit Data 3 RD Receive Data + 4 TERM1 Termination Network 1 5 TERM1 Termination Network 1 6 RD_N Receive Data 7 TERM2 Termination Network 2 8 TERM2 Termination Network 1 Procedure Watch video sequence "Connect BusAdapter BA 2xRJ45 to the ET 200SP interface module" ( To connect PROFINET IO to the PROFINET device via the BusAdapter BA 2xRJ45, follow these steps: 1. Plug the BusAdapter BA 2 RJ45 into the PROFINET device. 2. Screw the BusAdapter BA 2 RJ45 to the PROFINET device (1 screw with 0.2 Nm tightening torque). 3. Plug the RJ45 bus connector into the PROFINET port on the BusAdapter BA 2 RJ45. You can also swap steps 2 and 3. Siemens Controls BusAdapter 16 Manual, 03/2018, A5E AA

18 BusAdapter BA 2xRJ Connecting BusAdapter BA 2 RJ45 installed CPU Figure 4-2 BusAdapter BA 2 RJ45 PROFINET connecting cable Interface module BusAdapter BA 2 RJ45 installed (using an ET 200SP CPU/interface module as an example) Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent). Only then are you permitted to operate the modules with PROFINET IO interfaces in LAN networks (Local Area Networks). A data transfer point that guarantees this degree of safety is prescribed for connection to the WAN (Wide Area Network). BusAdapter Manual, 03/2018, A5E AA 17

19 BusAdapter BA 2xRJ Diagnostics 4.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA 2xRJ45: 1 2 LK1 (green) LK2 (green) Figure 4-3 LEDs on the BusAdapter BA 2xRJ45 LK1/LK2 LEDs on the BusAdapter Table 4-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is an Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. Check whether the bus cable to the switch or IO controller is disconnected. - - Siemens Controls BusAdapter 18 Manual, 03/2018, A5E AA

20 BusAdapter BA 2xRJ Technical specifications 4.4 Technical specifications Technical specifications of the BusAdapter BA 2 RJ45 Article number 6ES7193-6AR00-0AA0 Interfaces Number of PROFINET interfaces 1 PROFINET IO RJ 45 Yes; 2 x FC (FastConnect) No Number of SCRJ ports 0 Number of LC ports 0 Cable length Cu conductors 100 m Dimensions Width Height Depth Weights Weight, approx. 20 mm 69.5 mm 59 mm 46 g BusAdapter Manual, 03/2018, A5E AA 19

21 BusAdapter BA 2xFC Product overview Article number 6ES7193-6AF00-0AA0 View Figure 5-1 BusAdapter BA 2xFC Properties You connect PROFINET IO cable with FastConnect connection method to the PROFINET device via the BusAdapter BA 2xFC. To do this, screw the BusAdapter BA 2xFC with the connected PROFINET connection cable in place on the PROFINET device. You loop through the PROFINET via the integrated 2-port switch. Siemens Controls BusAdapter 20 Manual, 03/2018, A5E AA

22 BusAdapter BA 2xFC 5.2 Connecting 5.2 Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide ( Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required If you use Fast Connect Cable, we recommend the Industrial Ethernet Fast Connect Stripping Tool (6GK1901-1GA00) with green knife cassette (6GK1901-1B). This guarantees fast and safe stripping. Fast Connect Cable (recommended types): IE FC TP Standard Cable GP 2x2 (6XV1840-2AH10) IE FC TP Trailing Cable 2x2 (6XV1840-3AH10) IE FC TP Marine Cable (6XV1840-4AH10) IE FC TP Flexible Cable GP 2x2 (6XV1870-2B) IE FC TP Trailing Cable 2x2 (6XV1870-2D) IE TP Torsion Cable 2x2 (6XV1870-2F) FC TP FRNC Cable GP (6XV1871-2F) IE FC TP Food Cable GP 2x2 (6XV1871-2L) IE FC TP Festoon Cable 2x2 (6XV1871-2S) Please observe the specifications in the PROFINET Installation Guide ( BusAdapter Manual, 03/2018, A5E AA 21

23 BusAdapter BA 2xFC 5.2 Connecting Pin assignment The following table shows the signal name and description of the pin assignment of BusAdapter BA 2 FC:. Table 5-1 PROFINET IO pin assignment with BusAdapter BA 2 FC View Signal name Description 1 RD_N Receive Data - 2 TD_N Transmit Data - 3 RD Receive Data + 4 TD Transmit Data + Procedure Watch the video sequence "Connecting the BusAdapter BA 2xFC to the interface module" ( To connect PROFINET IO to the PROFINET device via the BusAdapter BA 2xFC, follow these steps: 1. Strip insulation from the sheath of the PROFINET connecting cable as follows: Figure 5-2 PROFINET connecting cable 2. Pull back the locking slide and fold up the cover of the connection element. 3. Pull up the wire guide as far as it will go. 4. Insert the unstripped single cores of the PROFINET connecting cable into the cable routing as far as it will go. Firmly press down the wire guide as far as it will go. Please refer to the color coding. Siemens Controls BusAdapter 22 Manual, 03/2018, A5E AA

24 BusAdapter BA 2xFC 5.2 Connecting 5. Close the cover of the connection element. Then push the locking slide forwards as far as it will go. 6. Screw the BusAdapter BA 2 FC to the PROFINET device (1 screw with 0.2 Nm tightening torque). To do this, use a screwdriver with a 3 to 3.5 mm blade, alternatively TX10. 1 Locking slide 3 Shield contact 2 Wire guide 4 PROFINET connecting cable Figure 5-3 Connection of the PROFINET IO BusAdapter BA 2 FC BusAdapter Manual, 03/2018, A5E AA 23

25 BusAdapter BA 2xFC 5.2 Connecting BusAdapter BA 2xFC installed CPU Figure 5-4 BA 2xFC BusAdapter PROFINET connecting cable Connection element BusAdapter BA 2xFC installed (using an ET 200SP CPU/interface module as an example) Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent). Only then are you permitted to operate the modules with PROFINET IO interfaces in LAN networks (Local Area Networks). A data transfer point that guarantees this degree of safety is prescribed for connection to the WAN (Wide Area Network). Siemens Controls BusAdapter 24 Manual, 03/2018, A5E AA

26 BusAdapter BA 2xFC 5.3 Diagnostics 5.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA 2xFC: 1 2 LK1 (green) LK2 (green) Figure 5-5 LEDs on the BusAdapter BA 2xFC LK1/LK2 LEDs on the BusAdapter Table 5-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. Check whether the bus cable to the switch or IO controller is disconnected. - - BusAdapter Manual, 03/2018, A5E AA 25

27 BusAdapter BA 2xFC 5.4 Technical specifications 5.4 Technical specifications Technical specifications of the BusAdapters BA 2 FC Article number 6ES7193-6AF00-0AA0 Interfaces Number of PROFINET interfaces 1 PROFINET IO FC (FastConnect) Yes; 2 x Cable length Cu conductors 100 m Dimensions Width 20 mm Height 69.5 mm Depth 59 mm Weights Weight, approx. 53 g Siemens Controls BusAdapter 26 Manual, 03/2018, A5E AA

28 BusAdapter BA 2xSCRJ Product overview Article number 6ES7193-6AP00-0AA0 View Figure 6-1 BusAdapter BA 2xSCRJ Properties Using BusAdapter BA 2 SCRJ, you connect PROFINET IO to the PROFINET device optically with fiber-optic cables via an SCRJ connector. To do this, screw the BusAdapter BA 2 SCRJ to the PROFINET device and plug in the SCRJ connector. You loop through the PROFINET via the integrated 2-port switch. SCRJ connector is suitable for POF and PCF. BusAdapter Manual, 03/2018, A5E AA 27

29 BusAdapter BA 2xSCRJ 6.2 Connecting 6.2 Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide ( Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required Connector for PROFINET connection: IE SCRJ POF Plug Fiber-optic cable: IE POF standard cable (6XV1874-2A) IE POF trailing cable (6XV1874-2B) IE PCF standard cable (6XV1861-2A) IE PCF trailing cable (6XV1861-2C) IE PCF trailing cable, GI (6XV1861-2D) Siemens Controls BusAdapter 28 Manual, 03/2018, A5E AA

30 BusAdapter BA 2xSCRJ 6.2 Connecting Requirements Prepare the IE POF cables with the connectors IE SCRJ POF Plug or IE SC RJ PCF Plug. You will find more Instructions in the installation instructions: POF fiber-optic cables with IE SCRJ POF plugs (A5E ). PCF fiber-optic cables with IE SCRJ PCF plugs (A5E ). When installing the fiber-optic cable, make sure the bending radius is not less than permitted: IE POF/PCF standard cable: 150 mm IE POF/PCF trailing cable: 60 mm The maximum lengths of the fiber-optic cables are as follows: IE POF standard cable: 50 m IE POF trailing cable: 50 m IE POF standard cable: 100 m IE PCF trailing cable: 100 m IE PCF trailing cable, GI: 250 m When the PROFINET device is the last device of the fiber-optic cable network, the unoccupied fiber-optic cable interface must be closed with a blanking plug. When the modules ship, the blanking plugs are inserted in the PROFINET sockets of the BusAdapter. BusAdapter Manual, 03/2018, A5E AA 29

31 BusAdapter BA 2xSCRJ 6.2 Connecting Pin assignment The following table shows the signal name and description of the pin assignment of BusAdapter BA 2 SCRJ. Table 6-1 PROFINET IO pin assignment with BusAdapter BA 2 SCRJ View Signal name 1 2 Receive Data Transmit Data Description Procedure 1. Plug the BusAdapter BA 2 SCRJ into the PROFINET device. 2. Screw the BusAdapter BA 2 SCRJ to the PROFINET device (1 screw with 0.2 Nm tightening torque). To do this, use a screwdriver with a 3 to 3.5 mm blade, alternatively TX Remove the blanking plugs from the PROFINET sockets. 4. Hold the prepared connector by the housing. Insert it into the PROFINET socket on the BusAdapter BA 2xLC until you hear it click into place. The coding of the connectors ensures a safe connection. CAUTION Risk of damage to eyes Do not look directly into the opening of the optical transmitter diodes. The emitted light beam damages your eyes. You can swap steps 3 and 4. Siemens Controls BusAdapter 30 Manual, 03/2018, A5E AA

32 BusAdapter BA 2xSCRJ 6.2 Connecting BusAdapter BA 2 SCRJ installed Figure 6-2 Interface module BusAdapter BA 2xSCRJ PROFINET connecting cable (fiber-optic cable) BusAdapter BA 2 SCRJ connected to interface module (using ET 200SP interface module as an example) Reusing used fiber-optic cables Note Shorten both fiber-optic cores by the amount of the curved lengths and reassemble the connectors. This will prevent any attenuation losses caused by re-bent, heavily stressed portions of the fiber-optic cores. Reference For more information on the installation guidelines for fiber-optic cables, refer to the SIMATIC NET PROFIBUS Network Manual ( BusAdapter Manual, 03/2018, A5E AA 31

33 BusAdapter BA 2xSCRJ 6.3 Diagnostics 6.3 Diagnostics LEDs The figure below shows the LED display on the BusAdapter BA 2xSCRJ: LK1 (green) MT1 (yellow) LK2 (green) MT2 (yellow) Figure 6-3 LEDs on the BusAdapter BA 2xSCRJ Siemens Controls BusAdapter 32 Manual, 03/2018, A5E AA

34 BusAdapter BA 2xSCRJ 6.3 Diagnostics LK1/LK2 and MT1/MT2 LEDs on the BusAdapter Table 6-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes Not relevant Not relevant MT1/MT2 Not relevant Not relevant Not relevant off on There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is an Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. No error - Fiber-optic error Maintenance demanded: attenuation through the fiber-optic cable is already so high that operation will soon no longer be possible. Check whether the bus cable to the switch or IO controller is disconnected. - - Causes and measures for the transmission route: Replace the fiber-optic cable if damaged or aged. Ensure correct installation of the PROFINET plugs or PROFINET connectors. Adhere to maximum length of 50 m for POF cable or 100 m for PCF cable. Ensure that the FOC connectors fit securely. BusAdapter Manual, 03/2018, A5E AA 33

35 BusAdapter BA 2xSCRJ 6.4 Technical specifications 6.4 Technical specifications Technical specifications of BusAdapter BA 2 SCRJ Article number 6ES7193-6AP00-0AA0 Interfaces Number of PROFINET interfaces 1; 2 ports (switch) SCRJ FO PROFINET IO RJ 45 No FC (FastConnect) No Number of SCRJ ports 2 Number of LC ports 0 Cable length PCF 100 m Plastic FOC (POF) 50 m PCF-GI 250 m Dimensions Width 20 mm Height 69.5 mm Depth 59 mm Weights Weight, approx. 50 g Siemens Controls BusAdapter 34 Manual, 03/2018, A5E AA

36 BusAdapter BA SCRJ/RJ Product overview Article number 6ES7193-6AP20-0AA0 View 1 2 Fiber-optic cable SCRJ RJ45 Figure 7-1 BusAdapter BA SCRJ/RJ45 Properties You connect PROFINET IO connection cables to the PROFINET device via the BusAdapter BA SCRJ/RJ45: Optically with fiber-optic cables (FOC) with an SCRJ connector to port 1 Electrically with a standard RJ45 connector to port 2 To do this, screw the BusAdapter BA SCRJ/RJ45 to the PROFINET device and plug in the SCRJ connector or the RJ45 connector. You can loop through PROFINET IO via the integrated 2-port switch. You can use any port of the BusAdapter for feeding or for looping through. The integrated media converter converts the signals automatically. BusAdapter Manual, 03/2018, A5E AA 35

37 BusAdapter BA SCRJ/RJ Connecting 7.2 Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide ( Connecting the SCRJ connector You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2 SCRJ (Page 28). Connecting the RJ45 connector You can find more information about the required tools, accessories and procedures in the section Connecting BusAdapter BA 2 RJ45 (Page 15). Pin assignment The following table shows the signal names and description of the pin assignment for the BusAdapter BA SCRJ/RJ45: Table 7-1 PROFINET IO pin assignment with BusAdapter BA SCRJ/RJ45 View Signal name Description 1 Receive Data Transmit Data 2 1 TD Transmit Data + 2 TD_N Transmit Data - 3 RD Receive Data + 4 TERM1 Termination Network 1 5 TERM1 Termination Network 1 6 RD_N Receive Data - 7 TERM2 Termination Network 2 8 TERM2 Termination Network 2 Siemens Controls BusAdapter 36 Manual, 03/2018, A5E AA

38 BusAdapter BA SCRJ/RJ Connecting BA SCRJ/RJ45 BusAdapter mounted Interface module BusAdapter BA SCRJ/RJ45 PROFINET connecting cable Figure 7-2 Connecting the BusAdapter BA SCRJ/RJ45 to the interface module Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent). Only then are you permitted to operate the modules with PROFINET IO interfaces in LAN networks (Local Area Networks). A data transfer point that guarantees this degree of safety is prescribed for connection to the WAN (Wide Area Network). BusAdapter Manual, 03/2018, A5E AA 37

39 BusAdapter BA SCRJ/RJ Diagnostics 7.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA SCRJ/RJ45: LK1 (green) MT (yellow) LK2 (green) Figure 7-3 LED displays on the BusAdapter BA SCRJ/RJ45 Siemens Controls BusAdapter 38 Manual, 03/2018, A5E AA

40 BusAdapter BA SCRJ/RJ Diagnostics LK1/LK2 and MT LEDs on the BusAdapter Table 7-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes Not relevant Not relevant MT Not relevant Not relevant Not relevant off on There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is an Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. No error - Fiber-optic error Maintenance demanded: attenuation through the fiber-optic cable is already so high that operation will soon no longer be possible. Check whether the bus cable to the switch or IO controller is disconnected. - - Causes and measures for the transmission route: Replace the fiber-optic cable if damaged or aged. Ensure correct installation of the PROFINET plugs or PROFINET connectors. Adhere to maximum length of 50 m for POF cable or 100 m for PCF cable. Ensure that the FOC connectors fit securely. BusAdapter Manual, 03/2018, A5E AA 39

41 BusAdapter BA SCRJ/RJ Technical specifications 7.4 Technical specifications Technical specifications of BusAdapter BA SCRJ/RJ45 Article number 6ES7193-6AP20-0AA0 Interfaces Number of PROFINET interfaces 1; 2 ports (SCRJ + RJ45) PROFINET IO RJ 45 Yes; 1x FC (FastConnect) No Number of SCRJ ports 1 Number of LC ports 0 Cable length PCF 100 m Plastic FOC (POF) 50 m PCF-GI 250 m Cu conductors 100 m Dimensions Width 20 mm Weights Weight, approx. 50 g Siemens Controls BusAdapter 40 Manual, 03/2018, A5E AA

42 BusAdapter BA SCRJ/FC Product overview Article number 6ES7193-6AP40-0AA0 View 1 2 SCRJ fiber-optic cable FastConnect FC Figure 8-1 BusAdapter BA SCRJ/FC Properties You connect PROFINET IO to the PROFINET device via the BusAdapter BA SCRJ/FC. The BusAdapter BA SCRJ/FC has one port for connection of a copper cable and one port for connection of a fiber-optic cable. Screw the BusAdapter BA SCRJ/FC with the attached Fast Connect bus cable onto the interface module and plug in the SCRJ connector. You loop through the PROFINET IO via the integrated 2-port switch. You can use any port of the BusAdapter for feeding or for looping through. The integrated media converter converts the signals automatically. BusAdapter Manual, 03/2018, A5E AA 41

43 BusAdapter BA SCRJ/FC 8.2 Connecting 8.2 Connecting Installing the bus connector Install the PROFINET connector according to the instructions in the PROFINET Installation Guide ( Connecting the SCRJ connector You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2 SCRJ (Page 28). Connecting the RJ45 connector You can find more information about the required tools, accessories and procedures in the section Connecting BusAdapter BA 2 FC (Page 21). Pin assignment The following table shows the signal name and description of the pin assignment of BusAdapter BA SCRJ/FC. Table 8-1 PROFINET IO pin assignment with BusAdapter BA SCRJ/FC View Signal name Description 1 Receive Data 2 Transmit Data 1 RD_N Receive Data 2 TD_N Transmit Data - 3 RD Receive Data + 4 TD Transmit Data + Siemens Controls BusAdapter 42 Manual, 03/2018, A5E AA

44 BusAdapter BA SCRJ/FC 8.2 Connecting Procedure To connect PROFINET IO to the PROFINET device via the BusAdapter BA SCRJ/FC, follow these steps: 1. Plug the BusAdapter BA SCRJ/FC into the PROFINET device. 2. Screw the BusAdapter BA SCRJ/FC to the PROFINET device (1 screw with 0.2 Nm tightening torque). To do this, use a screwdriver with a 3 to 3.5 mm blade, alternatively TX Plug the RJ45 bus connector into the PROFINET port on the BusAdapter BA SCRJ/FC. BA SCRJ/FC BusAdapter mounted Interface module BusAdapter BA SCRJ/FC PROFINET connecting cable Figure 8-2 BusAdapter BA SCRJ/FC installed (using an ET 200SP interface module as an example) Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent). Only then are you permitted to operate the modules with PROFINET IO interfaces in LAN networks (Local Area Networks). A data transfer point that guarantees this degree of safety is prescribed for connection to the WAN (Wide Area Network). BusAdapter Manual, 03/2018, A5E AA 43

45 BusAdapter BA SCRJ/FC 8.3 Diagnostics 8.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA SCRJ/FC: LK1 (green) MT (yellow) LK2 (green) Figure 8-3 LEDs on the BusAdapter BA SCRJ/FC Siemens Controls BusAdapter 44 Manual, 03/2018, A5E AA

46 BusAdapter BA SCRJ/FC 8.3 Diagnostics LK1/LK2 and MT LEDs on the BusAdapter Table 8-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes Not relevant Not relevant MT Not relevant Not relevant Not relevant off on There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is an Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. No error - Fiber-optic error Maintenance demanded: attenuation through the fiber-optic cable is already so high that operation will soon no longer be possible. Check whether the bus cable to the switch or IO controller is disconnected. - - Causes and measures for the transmission route: Replace the fiber-optic cable if damaged or aged. Ensure correct installation of the PROFINET plugs or PROFINET connectors. Adhere to maximum length of 50 m for POF cable or 100 m for PCF cable. Ensure that the FOC connectors fit securely. BusAdapter Manual, 03/2018, A5E AA 45

47 BusAdapter BA SCRJ/FC 8.4 Technical specifications 8.4 Technical specifications Technical specifications of BusAdapter BA SCRJ/FC Article number 6ES7193-6AP40-0AA0 Interfaces Number of PROFINET interfaces 1; 2 ports (SCRJ + FC) PROFINET IO RJ 45 No FC (FastConnect) Yes; 1x Number of SCRJ ports 1 Number of LC ports 0 Cable length PCF 100 m Plastic FOC (POF) 50 m PCF-GI 250 m Cu conductors 100 m Dimensions Width 20 mm Height 69.5 mm Depth 59 mm Weights Weight, approx. 50 g Siemens Controls BusAdapter 46 Manual, 03/2018, A5E AA

48 BusAdapter BA 2xLC Product overview Article number 6ES7193-6AG00-0AA0 View Figure 9-1 BusAdapter BA 2xLC Properties You connect PROFINET IO fiber-optic cables to the PROFINET device via the BusAdapter BA 2 LC. To do this, screw the BusAdapter BA 2 LC to the PROFINET device and insert the PROFINET connection cable. You loop through the PROFINET via the integrated 2-port switch. BusAdapter Manual, 03/2018, A5E AA 47

49 BusAdapter BA 2xLC 9.2 Connecting 9.2 Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide ( Tools required 3 to 3.5 mm screwdriver, alternatively TX10 (torx). Accessories required If you prepare the FC FO cables with the IE FC FO LC plug, we recommend the FC FO Termination Kit (LC) (6GK1900-0RL00-0AA0). You can cleave the glass fiber precisely using the FC FO Termination Kit (LC). CAUTION Cleaving the glass fiber Wear protective glasses during the cleaving process. Dispose of the remaining fibers in a suitable waste container. Connector for PROFINET fiber-optic cable connection: IE FC FO LC Plug (10 duplex plugs: 6GK1900-1RB00-2AB0) Fiber-optic cable: IE FC FO Standard Cable GP (62.5/200/230) (6XV1847-2A) IE FC FO Trailing Cable (62.5/200/230) (6XV1847-2C) IE FC FO Robust Cable (6XV1873-5Rxx) IE FC FO Standard Cable (6XV1873-3Axx) Siemens Controls BusAdapter 48 Manual, 03/2018, A5E AA

50 BusAdapter BA 2xLC 9.2 Connecting Pin assignment The following table shows the signal name and description of the pin assignment of BusAdapter BA 2 LC: Table 9-1 PROFINET IO pin assignment with BusAdapter BA 2xLC View Signal name 1 2 Receive Data Transmit Data Description Requirements Prepare the IE FC FO cable with the IE FC FO LC plug connectors. For detailed instructions, refer to the assembly instructions Preparing IE FC FO Cable with the plug-in connector IE FC FO LC Plug (A5E ). When installing the fiber-optic cable, make sure the bending radius is not less than permitted: IE FC FO Standard Cable GP (62.5/200/230): 70 mm IE FC FO Trailing Cable (62.5/200/230) (6XV1847-2C): 88 mm The maximum lengths of the fiber-optic cables are as follows: IE FC FO Standard Cable GP (62.5/200/230): 2 km IE FC FO Trailing Cable (62.5/200/230): 2 km When the interface module is the last device of the fiber-optic cable network, the unoccupied fiber-optic cable interface must be closed with a blanking plug. When the modules ship, the blanking plugs are inserted in the PROFINET sockets of the BusAdapter. BusAdapter Manual, 03/2018, A5E AA 49

51 BusAdapter BA 2xLC 9.2 Connecting Procedure To connect PROFINET IO to the PROFINET device via the BusAdapter BA 2xLC, follow these steps: 1. Plug the BusAdapter BA 2xLC into the PROFINET device. 2. Screw the BusAdapter BA 2xLC to the PROFINET device (1 screw with 0.2 Nm tightening torque). To do this, use a screwdriver with a 3 to 3.5 mm blade, alternatively TX Remove the blanking plugs from the PROFINET sockets. 4. Hold the prepared connector by the housing. Insert it into the PROFINET socket on the BusAdapter BA 2xLC until you hear it click into place. The coding of the connectors ensures a safe connection. CAUTION Risk of damage to eyes Do not look directly into the opening of the optical transmitter diodes. The emitted light beam damages your eyes. Siemens Controls BusAdapter 50 Manual, 03/2018, A5E AA

52 BusAdapter BA 2xLC 9.2 Connecting BusAdapter BA 2xLC installed Interface module BusAdapter BA 2xLC PROFINET glass fiber connecting cable Figure 9-2 Connecting the BusAdapter BA 2xLC to the interface module Reusing used fiber-optic cables Note Shorten both fiber-optic cores by the amount of the curved lengths and reassemble the connectors. This will prevent any attenuation losses caused by re-bent, heavily stressed portions of the fiber-optic cores. Reference For more information on the installation guidelines for fiber-optic cables, refer to the SIMATIC NET PROFIBUS Network Manual ( BusAdapter Manual, 03/2018, A5E AA 51

53 BusAdapter BA 2xLC 9.3 Diagnostics 9.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA 2xLC: 1 2 LK1 (green) LK2 (green) Figure 9-3 LEDs on the BusAdapter BA 2xLC LK1/LK2 LEDs on the BusAdapter Table 9-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. Check whether the bus cable to the switch or IO controller is disconnected. - - Siemens Controls BusAdapter 52 Manual, 03/2018, A5E AA

54 BusAdapter BA 2xLC 9.4 Technical specifications 9.4 Technical specifications Technical specifications of BusAdapter BA 2xLC Article number Interfaces Number of PROFINET interfaces PROFINET IO RJ 45 No FC (FastConnect) No Number of SCRJ ports 0 6ES7193-6AG00-0AA0 1; 2 ports (switch) LC Multimode Glass Fibre Number of LC ports 2; Wavelength of nm, corresponds to 100BASE-FX Cable length Multimode graded-index fiber 50/125 µm 3 km Multimode graded-index fiber 62.5/125 μm 3 km Ambient conditions Ambient temperature during operation min. 0 C max. 60 C Dimensions Width Height Depth 20 mm 69.5 mm 59 mm BusAdapter Manual, 03/2018, A5E AA 53

55 BusAdapter BA LC/RJ Product overview Article number 6ES7193-6AG20-0AA0 View 1 2 Glass fiber-optic cable LC RJ45 Figure 10-1 BusAdapter BA LC/RJ45 Properties You connect PROFINET IO connection cables to the PROFINET device via the BusAdapter BA LC/RJ45: Optically with glass fiber-optic cables with an LC connector to port 1 Electrically with a standard RJ45 connector to port 2 To do this, screw the BusAdapter BA LC/RJ45 to the PROFINET device and plug in the LC connector or the RJ45 connector. You can loop through PROFINET IO via the integrated 2-port switch. You can use any port of the BusAdapter for feeding or for looping through. The integrated media converter converts the signals automatically. Siemens Controls BusAdapter 54 Manual, 03/2018, A5E AA

56 BusAdapter BA LC/RJ Connecting 10.2 Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide ( Attaching LC connectors You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2 LC (Page 48). Connecting the RJ45 connector You can find more information about the required tools, accessories and procedures in the section Connecting BusAdapter BA 2 RJ45 (Page 15). Pin assignment The following table shows the signal name and description of the pin assignment of BusAdapter BA LC/RJ45. Table 10-1 PROFINET IO pin assignment with BusAdapter BA LC/RJ45 View Signal name Description 1 Receive Data Transmit Data 2 1 TD Transmit Data + 2 TD_N Transmit Data - 3 RD Receive Data + 4 TERM1 Termination Network 1 5 TERM1 Termination Network 1 6 RD_N Receive Data - 7 TERM2 Termination Network 2 8 TERM2 Termination Network 2 BusAdapter Manual, 03/2018, A5E AA 55

57 BusAdapter BA LC/RJ Connecting BA LC/RJ45 BusAdapter mounted Interface module BA LC/RJ45 BusAdapter PROFINET connecting cable Figure 10-2 BusAdapter BA LC/RJ45 installed (using an ET 200SP interface module as an example) Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent). Only then are you permitted to operate the modules with PROFINET IO interfaces in LAN networks (Local Area Networks). A data transfer point that guarantees this degree of safety is prescribed for connection to the WAN (Wide Area Network). Siemens Controls BusAdapter 56 Manual, 03/2018, A5E AA

58 BusAdapter BA LC/RJ Diagnostics 10.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA LC/RJ45: 1 2 LK1 (green) LK2 (green) Figure 10-3 LED displays on the BusAdapter BA LC/RJ45 LEDs LK1/LK2 on the BusAdapter Table 10-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. Check whether the bus cable to the switch or IO controller is disconnected. - - BusAdapter Manual, 03/2018, A5E AA 57

59 BusAdapter BA LC/RJ Technical specifications 10.4 Technical specifications Technical specifications of the BusAdapters BA LC/RJ45 Article number Interfaces Number of PROFINET interfaces PROFINET IO RJ 45 Yes; 1x FC (FastConnect) No Number of SCRJ ports 0 Number of LC ports 1 Cable length Cu conductors 100 m Multimode graded-index fiber 50/125 µm Multimode graded-index fiber 62.5/125 μm Ambient conditions Ambient temperature during operation 6ES7193-6AG20-0AA0 1; 2 ports (switch) LC / RJ45 3 km 3 km min. 0 C max. 60 C Dimensions Width Height Depth Weights Weight, approx. 20 mm 69.5 mm 59 mm 32 g Siemens Controls BusAdapter 58 Manual, 03/2018, A5E AA

60 BusAdapter BA LC/FC Product overview Article number 6ES7193-6AG40-0AA0 View 1 2 Glass fiber-optic cable LC FastConnect FC Figure 11-1 BusAdapter BA LC/FC Properties You connect PROFINET IO connection cables to the PROFINET device via the BusAdapter BA LC/FC: Optically with glass fiber-optic cables with an LC connector to port 1 Electrically with direct connection of the Fast Connect bus cable to port 2 Screw the BusAdapter BA LC/FC with the attached Fast Connect bus cable onto the PROFINET device and plug in the LC connector. You loop through the PROFINET IO via the integrated 2-port switch. You can use any port of the BusAdapter for feeding or for looping through. The integrated media converter converts the signals automatically. BusAdapter Manual, 03/2018, A5E AA 59

61 BusAdapter BA LC/FC 11.2 Connecting 11.2 Connecting Installing the bus connector Install the PROFINET connector in accordance with the instructions in the PROFINET Installation Guide ( Attaching LC connectors You can find more information about the required tools, accessories, requirements and procedures in the section Connecting BusAdapter BA 2 LC (Page 48). Connecting FastConnect bus cable You can find more information about the required tools, accessories and procedures in the section Connecting BusAdapter BA 2 FC (Page 21). Pin assignment The following table shows the signal name and description of the pin assignment of BusAdapter BA LC/FC. Table 11-1 PROFINET IO pin assignment with BusAdapter BA LC/FC View Signal name Description 1 Receive Data 2 Transmit Data 1 RD_N Receive Data 2 TD_N Transmit Data - 3 RD Receive Data + 4 TD Transmit Data + Siemens Controls BusAdapter 60 Manual, 03/2018, A5E AA

62 BusAdapter BA LC/FC 11.2 Connecting BusAdapter BA LC/FC installed Interface module BA LC/FC BusAdapter PROFINET connecting cable Figure 11-2 Connecting the BusAdapter BA LC/FC to the interface module Note Installation guidelines for modules with PROFINET IO interfaces Ensure that all devices are connected to the SELV/PELV power supply (or equivalent). Only then are you permitted to operate the modules with PROFINET IO interfaces in LAN networks (Local Area Networks). A data transfer point that guarantees this degree of safety is prescribed for connection to the WAN (Wide Area Network). BusAdapter Manual, 03/2018, A5E AA 61

63 BusAdapter BA LC/FC 11.3 Diagnostics 11.3 Diagnostics LEDs The figure below shows the LEDs on the BusAdapter BA LC/FC: 1 2 LK1 (green) LK2 (green) Figure 11-3 LEDs on the BusAdapter BA LC/FC LK1/LK2 LEDs on the BusAdapter Table 11-2 Status and error displays LED Meaning Remedy LK1/LK2 off on flashes There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. There is no Ethernet connection between the PROFINET IO interface of your PROFINET device and a communication partner, e.g. IO controller. The "Node flash test" is running. The RN/ER/MT LEDs are also flashing. Check whether the bus cable to the switch or IO controller is disconnected. - - Siemens Controls BusAdapter 62 Manual, 03/2018, A5E AA

64 BusAdapter BA LC/FC 11.4 Technical specifications 11.4 Technical specifications Technical specifications of the BusAdapters BA LC/FC Article number 6ES7193-6AG40-0AA0 Interfaces Number of PROFINET interfaces 1 PROFINET IO RJ 45 No FC (FastConnect) Yes; 1x Number of SCRJ ports 0 Number of LC ports 1 Cable length Cu conductors 100 m Multimode graded-index fiber 50/125 µm Multimode graded-index fiber 62.5/125 μm 3 km 3 km Ambient conditions Ambient temperature during operation min. 0 C max. 60 C Dimensions Width Height Depth Weights Weight, approx. 20 mm 69.5 mm 59 mm 50 g BusAdapter Manual, 03/2018, A5E AA 63

65 Strain relief Product overview Article number 6ES7193-6RA00-1AN0 (VPE: 5 strain relief units incl. screws) View Figure 12-1 Strain relief Properties The strain relief is a mechanical protective device for the electrical PROFINET cables on the BusAdapter. The strain relief is suitable for all optical and electrical PROFINET cables of the BusAdapter. The strain relief is an optional accessories. The cable ties are not included in the delivery. We recommend cable ties with a width of 4.8 mm. The maximum width is 7.0 mm. The length of the cable tie is min. 60 mm. Siemens Controls BusAdapter 64 Manual, 03/2018, A5E AA

66 Strain relief 12.2 Installing 12.2 Installing Requirement The PROFINET cables are not inserted on the BusAdapter. The inserted PROFINET cables hamper the mounting of the strain relief. BusAdapter and strain relief can be mounted separately. Tools required Screwdriver TX10 (torx). Procedure To install the strain relief, follow these steps: 1. Press the strain relief below the BusAdapter seat of the PROFINET device. Figure 12-2 Strain relief before mounting 2. Fasten the strain relief (1 screw with 0.7 to 0.8 Nm tightening torque). 3. Plug the BusAdapter into the PROFINET device. BusAdapter Manual, 03/2018, A5E AA 65

67 Strain relief 12.2 Installing 4. Screw the BusAdapter to the PROFINET device (1 screw with 0.2 Nm tightening torque). 5. Attach the PROFINET cables with the cable ties to the strain relief. Figure 12-3 Strain relief installed Siemens Controls BusAdapter 66 Manual, 03/2018, A5E AA

68 Dimension drawings A A.1 BusAdapter dimension drawings The figure below shows the dimension drawing of the BusAdapter BA 2xRJ45 as an example. Figure A-1 Dimensional drawing of BusAdapter BA 2xRJ45 A.2 Strain relief dimension drawings The figure below shows the dimension drawing of the strain relief. Figure A-2 Strain relief dimension drawing BusAdapter Manual, 03/2018, A5E AA 67

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL. Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection

More information

SIMATIC. Bus links PN/PN coupler. Preface. Documentation guide. Product overview. Assembling 3. Connecting 4. Configuring, parameter assignment and

SIMATIC. Bus links PN/PN coupler. Preface. Documentation guide. Product overview. Assembling 3. Connecting 4. Configuring, parameter assignment and Preface Documentation guide 1 SIMATIC Bus links Hardware Installation and Operating Manual Product overview 2 Assembling 3 Connecting 4 Configuring, parameter assignment and 5 commissioning Functions 6

More information

SIMATIC. S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Preface. Documentation guide. Product overview. Preface Documentation guide 1 SIMATIC S7-1500/ET 200MP DI 16x230VAC BA Digital Input Module (6ES7521-1FH00-0AA0) Manual Product overview 2 Wiring 3 Address space 4 Diagnostic alarms 5 Technical specifications

More information

SIMATIC. S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Preface. Documentation guide. Product overview. Preface Documentation guide 1 SIMATIC S7-1500/ET 200MP Digital input module DI 16x24VDC BA (6ES7521-1BH10-0AA0) Manual Product overview 2 Wiring 3 Address space 4 Diagnostics alarms 5 Technical specifications

More information

IM PN HS interface module (6ES7155-6AU00-0DN0) SIMATIC. ET 200SP IM PN HS interface module (6ES7155-6AU00-0DN0) Preface

IM PN HS interface module (6ES7155-6AU00-0DN0) SIMATIC. ET 200SP IM PN HS interface module (6ES7155-6AU00-0DN0) Preface IM 155-6 PN HS interface module (6ES7155-6AU00-0DN0) SIMATIC ET 200SP IM 155-6 PN HS interface module (6ES7155-6AU00-0DN0) Manual Preface Documentation guide 1 Product overview 2 Connecting 3 Parameters/address

More information

SIMATIC. S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU Memory. Preface. Documentation guide. Memory areas and retentive memory

SIMATIC. S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU Memory. Preface. Documentation guide. Memory areas and retentive memory Preface Documentation guide 1 SIMATIC S7-1500, ET 200SP, ET 200pro Structure and Use of the CPU Memory Memory areas and retentive memory 2 Memory usage and application examples 3 SIMATIC memory card 4

More information

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview. IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address space 4 Diagnostics alarms

More information

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2 BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Manual Preface Guide to the documentation 1 Product overview 2 BaseUnits for I/O modules 3 BaseUnits

More information

IM PN HF interface module (6ES7155-6AU00-0CN0) SIMATIC. ET 200SP IM PN HF interface module (6ES7155-6AU00-0CN0) Preface

IM PN HF interface module (6ES7155-6AU00-0CN0) SIMATIC. ET 200SP IM PN HF interface module (6ES7155-6AU00-0CN0) Preface IM 155-6 PN HF interface module (6ES7155-6AU00-0CN0) SIMATIC ET 200SP IM 155-6 PN HF interface module (6ES7155-6AU00-0CN0) Manual Preface ET 200SP Documentation Guide 1 Product overview 2 Wiring 3 Parameters/address

More information

SIMATIC. ET 200SP Interface module IM PN/2 HF (6ES7155-6AU01-0CN0) Preface. Guide. Product overview. Wiring 3. Parameters/address space

SIMATIC. ET 200SP Interface module IM PN/2 HF (6ES7155-6AU01-0CN0) Preface. Guide. Product overview. Wiring 3. Parameters/address space Preface Guide 1 SIMATIC ET 200SP Interface module IM 155-6 PN/2 HF (6ES7155-6AU01-0CN0) Manual Product overview 2 Wiring 3 Parameters/address space 4 Interrupts, error messages, diagnostics and system

More information

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address

More information

SIMATIC. S7-1500/ET 200MP Digital output module DQ 32x24VDC/0.5A BA (6ES7522-1BL10-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. S7-1500/ET 200MP Digital output module DQ 32x24VDC/0.5A BA (6ES7522-1BL10-0AA0) Preface. Documentation guide. Product overview. Preface Documentation guide 1 SIMATIC S7-1500/ET 200MP Digital output module DQ 32x24VDC/0.5A BA (6ES7522-1BL10-0AA0) Manual Product overview 2 Wiring 3 Address space 4 Diagnostics alarms 5 Technical specifications

More information

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional Setting up security in STEP 7 Professional SIMATIC NET Industrial Ethernet Security Setting up security in STEP 7 Professional Preface 1 User interface and menu commands 2 Basic configuration 3 Firewall

More information

SIMATIC. ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Preface. Guide to the documentation. New properties. Product overview 3

SIMATIC. ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Preface. Guide to the documentation. New properties. Product overview 3 Preface Guide to the documentation 1 SIMATIC ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Manual New properties 2 Product overview 3 BaseUnits for I/O modules 4 BaseUnits for motor starters 5 Potential

More information

SIMATIC. S7-1500/ET 200MP Technology Module TM NPU (6ES7556-1AA00-0AB0) Preface. Documentation guide. Product overview. Wiring

SIMATIC. S7-1500/ET 200MP Technology Module TM NPU (6ES7556-1AA00-0AB0) Preface. Documentation guide. Product overview. Wiring SIMATIC S7-1500/ET 200MP Technology Module TM NPU (6ES7556-1AA00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Configuration / address space 4 Programming 5 Diagnostics 6 Technical

More information

Readme SiVArc V14 SP1 Update 6

Readme SiVArc V14 SP1 Update 6 Product version 1 Improvements in Update 6 2 Readme 05/2018 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as

More information

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1 Preface Connecting SCALANCE S615 to the WAN 1 SIMATIC NET VPN tunnel between SCALANCE S615 and 2 SINEMA RC Server Industrial Ethernet Security Getting Started 07/2017 C79000-G8976-C390-02 Legal information

More information

SIMATIC. ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Preface. Documentation guide. Product overview. Preface Documentation guide 1 SIMATIC ET 200SP Digital output module DI 8x24VDC SRC BA (6ES7131-6BF61-0AA0) Manual Product overview 2 Wiring 3 Parameters/address space 4 Interrupts/diagnostics alarms 5

More information

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC S7-1500/ET 200MP Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) Manual Preface Documentation guide 1 Product overview

More information

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2. Security information 1 Preface 2 SIMATIC Configuration 3 Process Control System PCS 7 Configuration McAfee Endpoint Security 10.5 Installation Manual 03/2018 A5E44395618-AA Legal information Warning notice

More information

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information SIMATIC Automation Tool features 1 Known problems 2 SIMATIC S7/HMI SIMATIC Automation Tool V3.1 SP1 product information Product Information V3.1 SP1, 05/2018 A5E43714043-AA Legal information Warning notice

More information

SIMATIC. S7-1500/ET 200MP Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Preface. Documentation guide. Product overview.

SIMATIC. S7-1500/ET 200MP Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Preface. Documentation guide. Product overview. Preface Documentation guide 1 SIMATIC S7-1500/ET 200MP Power supply module PS 60W 24/48/60VDC HF (6ES7505-0RB00-0AB0) Manual Product overview 2 Wiring 3 Parameters 4 Interrupts, diagnostic alarms, error

More information

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2 Use with 0 to 70 C ambient temperature SIMATIC Preface 1 Product combination 2 Product family 3 Process Control System PCS 7 Use with 0 to 70 C ambient temperature System Manual 02/2015 A5E35458345-AA

More information

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of Inter Project Engineering Team engineering via Inter Project Engineering TIA Portal Basics of "Inter Project Engineering" 1 Creating an IPE file 2 Importing an IPE file 3 Team engineering via Inter Project Engineering Getting Started

More information

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3

SIMATIC. PCS 7 Licenses and configuration limits (V9.0) Security information 1. Preface 2. Selecting the correct license keys 3 Security information 1 Preface 2 SIMATIC PCS 7 Licenses and configuration limits (V9.0) Selecting the correct license keys 3 Licensing of PC stations 4 Data volumes 5 Installation Manual Valid for PCS

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Automation System S7-300: Getting Started CPU 31xC: Commissioning Introduction 1 Preparation 2 SIMATIC S7-300 Automation System S7-300: Getting Started CPU 31xC: Commissioning Learning units 3 Further

More information

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations Introduction 1 Configuring a reversing starter 2 Industrial Controls A List of abbreviations Motor management and control devices Getting Started 05/2018 A5E40507294002A/RS-AB/002 Legal information Warning

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01

More information

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1] Loading the block library 1 Deleting program block Main [OB1] 2 TIA Portal SIMATIC Getting Started Copying program blocks 3 Copying tag tables 4 Compiling a project 5 Load project into the CPU 6 03/2013

More information

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual

SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Functions 1. Software installation 2. Operation. Configuration Manual Preface Functions 1 SIMATIC NET Industrial Ethernet / PROFINET Software installation 2 Operation 3 Configuration Manual 04/2017 C79000-G8976-C204-07 Legal information Warning notice system This manual

More information

ST (6ES7132-6FD00-0BB1)

ST (6ES7132-6FD00-0BB1) SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ

More information

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4. Security information 1 Overview 2 SIMATIC Process Control System PCS 7 Notes on Installation 3 Notes on usage 4 Readme 04/2016 A5E36515375-AA Legal information Warning notice system This manual contains

More information

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Configuration Symantec Endpoint Protection V14. Security information 1. Preface 2. Security information 1 Preface 2 SIMATIC Configuration 3 Process Control System PCS 7 Configuration Symantec Endpoint Protection V14 Commissioning Manual 03/2018 A5E44395521-AA Legal information Warning

More information

SIMATIC. ET 200AL Interface module IM DP (6ES7157-1AA00-0AB0) Preface. Documentation guide. Product overview. Wiring 3.

SIMATIC. ET 200AL Interface module IM DP (6ES7157-1AA00-0AB0) Preface. Documentation guide. Product overview. Wiring 3. Preface Documentation guide 1 SIMATIC ET 200AL Interface module IM 157-1 DP (6ES7157-1AA00-0AB0) Manual Product overview 2 Wiring 3 Parameters 4 Interrupts, error messages, diagnostics and system 5 alarms

More information

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview. Preface Guide to documentation 1 SIMATIC ET 200SP DQ 4x24..230VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Manual Product overview 2 Wiring 3 Parameter assignment/addressing 4 Interrupts/diagnostics

More information

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties. Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 06/2010

More information

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

SIMATIC. Process Control System PCS 7 CFC Readme V9.0 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4. Security information 1 Overview 2 SIMATIC Process Control System PCS 7 Notes on Installation 3 Notes on usage 4 Readme V9.0 A5E39595586-AA Legal information Warning notice system This manual contains notices

More information

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2

SIMATIC. Process control system PCS 7 Operator Station (V9.0 SP1) Security information 1. Preface 2 SIMATIC Process control system PCS 7 Configuration Manual Valid for PCS 7 as of V9.0 SP1 Security information 1 Preface 2 The PCS 7 Operator Station 3 Introduction to OS configuration 4 Setting the languages

More information

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1 Options for Accessing Documentation 1 Notes on the Product Documentation 2 SIMATIC Notes on the PCS 7 V8.0 SP2 system documentation 3 Process Control System PCS 7 PCS 7 system documentation - Readme V8.0

More information

SIMATIC. ET 200SP Digital output module RQ 4x24VUC/2A CO ST (6ES7132-6GD51-0BA0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200SP Digital output module RQ 4x24VUC/2A CO ST (6ES7132-6GD51-0BA0) Preface. Documentation guide. Product overview. Preface Documentation guide 1 SIMATIC ET 200SP Digital output module RQ 4x24VUC/2A CO ST (6ES7132-6GD51-0BA0) Manual Product overview 2 Wiring 3 Parameters/address space 4 Interrupts/diagnostics alarms

More information

SIMATIC. ET 200SP Digital input module DI 8x24VDC BA (6ES7131-6BF01-0AA0) Preface. Documentation guide 1. Product overview 2.

SIMATIC. ET 200SP Digital input module DI 8x24VDC BA (6ES7131-6BF01-0AA0) Preface. Documentation guide 1. Product overview 2. Preface Documentation guide 1 SIMATIC ET 200SP Digital input module DI 8x24VDC BA (6ES7131-6BF01-0AA0) Manual Product overview 2 Wiring 3 Parameters/address space 4 Interrupts/diagnostics alarms 5 Technical

More information

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO

SIMATIC. SIMATIC Energy Manager V1.0 App for ios and Android. Preface. SIMATIC Energy Manager app. Establish connection to SIMATIC Energy Manager PRO Preface SIMATIC Energy Manager app 1 SIMATIC SIMATIC Energy Manager V1.0 App for ios and Android Establish connection to SIMATIC Energy Manager 2 PRO Mobile data acquisition 3 Working with data points

More information

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) SIMATIC ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Connecting 3 Parameter

More information

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3

SIMATIC. Process Control System PCS 7 Advanced Process Functions Operator Manual. Preface. Security information 1. Overview 2. Material management 3 Preface Security information 1 SIMATIC Process Control System PCS 7 Advanced Process Functions Operator Manual Operating Manual Overview 2 Material management 3 Material lot management 4 Storage location

More information

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1.

Siemens Industrial SIMATIC. Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG. Security information 1. Security information 1 Preface 2 SIMATIC Configuration 3 Process Control System PCS 7 Configuration Trend Micro OfficeScan Server XG Commissioning Manual Siemens Industrial 03/2018 A5E44395601-AA Legal

More information

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0) 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- SIMATIC Preface 1 Properties 2 Diagnostics 3 ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- Manual 10/2015

More information

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example Introduction 1 Application example 2 Industrial Controls Motor management and control devices SIMOCODE pro - Application examples Application Manual Example circuits control functions 3 Further application

More information

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3 Getting Started - Startdrive Introduction 1 Connecting the drive unit to the PC 2 Startdrive SINAMICS Getting Started Creating a project 3 Going online and incorporating devices 4 Commissioning the drive

More information

IM PN ST interface module (6ES7155-6AU00-0BN0) SIMATIC. ET 200SP IM PN ST interface module (6ES7155-6AU00-0BN0) Preface

IM PN ST interface module (6ES7155-6AU00-0BN0) SIMATIC. ET 200SP IM PN ST interface module (6ES7155-6AU00-0BN0) Preface IM 155-6 PN ST interface module (6ES7155-6AU00-0BN0) SIMATIC ET 200SP IM 155-6 PN ST interface module (6ES7155-6AU00-0BN0) Manual Preface ET 200SP Documentation Guide 1 Product overview 2 Wiring 3 Parameters/address

More information

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode Global FW Rulesets SIMATIC NET Industrial Ethernet Security Preface 1 Firewall in standard mode 2 Firewall in advanced mode 3 Configuring a VPN tunnel 4 Configuring remote access via a VPN tunnel 5 Getting

More information

Interface module IM DP (6ES7157-1AA00-0AB0) SIMATIC. ET 200AL Interface module IM DP (6ES7157-1AA00-0AB0) Preface. Documentation guide

Interface module IM DP (6ES7157-1AA00-0AB0) SIMATIC. ET 200AL Interface module IM DP (6ES7157-1AA00-0AB0) Preface. Documentation guide Interface module IM 157-1 DP (6ES7157-1AA00-0AB0) SIMATIC ET 200AL Interface module IM 157-1 DP (6ES7157-1AA00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters 4 Configuration

More information

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties. Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual

More information

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3 1BProduct information on CPU 1515SP PC Preface Product Information 1 SIMATIC ET 200SP Open Controller Technical update 2 Technical specifications 3 Product Information 09/2015 A5E35456639-AC 3BLegal information

More information

IM PN BA interface module (6ES7155-6AR00-0AN0) SIMATIC. ET 200SP IM PN BA interface module (6ES7155-6AR00-0AN0) Preface

IM PN BA interface module (6ES7155-6AR00-0AN0) SIMATIC. ET 200SP IM PN BA interface module (6ES7155-6AR00-0AN0) Preface IM 155-6 PN BA interface module (6ES7155-6AR00-0AN0) SIMATIC ET 200SP IM 155-6 PN BA interface module (6ES7155-6AR00-0AN0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address

More information

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3.

SIMATIC. PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Security information 1. Overview 2. Notes on installation 3. Security information 1 Overview 2 SIMATIC PCS 7 Process Control System SIMATIC Logon Readme V1.6 (Online) Notes on installation 3 Notes on usage 4 Readme V1.6 02/2017 A5E40700191-AA Legal information Warning

More information

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0) SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01- SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3. Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01 Safety Guidelines This manual contains notices

More information

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters

More information

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system Safety instructions 1 Initial startup: Commissioning the operating system 2 SIMATIC Industrial PC Operating Instructions Restoring the factory settings of the operating system and partitions(restore) 3

More information

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

MindSphere. Visual Explorer. Introduction. User roles for Visual Explorer Connecting Visual Explorer to MindSphere data. Creating Visualizations Introduction 1 User roles for "Visual Explorer" 2 MindSphere Connecting "" to MindSphere data 3 Creating Visualizations 4 Getting Started 06/2018 Legal information Warning notice system This manual contains

More information

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1

SIMATIC NET. Industrial Remote Communication - Remote Networks SINEMA Remote Connect - Client. Preface. Requirements for operation 1 Preface Requirements for operation 1 SIMATIC NET Industrial Remote Communication - Remote Networks Installation and commissioning 2 Configuration 3 Operating Instructions 11/2017 C79000-G8976-C395-04 Legal

More information

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction Fundamental safety instructions 1 Introduction 2 SIMATIC/SINAMICS Getting started with SINAMICS V90 PN on S7-1500 Motion Control Getting Started Prepare the configuration 3 Create a project 4 Creating

More information

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730. Performance data 802.11 abgn SCALANCE W770/W730 Technical data 1 SIMATIC NET Industrial Wireless LAN Performance data 802.11 abgn SCALANCE W770/W730 Reference Manual 07/2014 C79000-G8976-C370-01 Legal

More information

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3

Cycle and response times SIMATIC. S Cycle and response times. Preface. Documentation guide. Program processing 2. Cyclic program processing 3 Preface Documentation guide 1 SIMATIC S7-1500 Program processing 2 Cyclic program processing 3 Event-driven program processing 4 Function Manual 02/2014 A5E03461504-02 Legal information Warning notice

More information

Preface. Guide SIMATIC. System overview. Integration into the automation system 3. IO-Link system. Function Manual 12/2017 A5E AB

Preface. Guide SIMATIC. System overview. Integration into the automation system 3. IO-Link system. Function Manual 12/2017 A5E AB Preface Guide 1 SIMATIC System overview 2 Integration into the automation system 3 Function Manual 12/2017 A5E31637677-AB Legal information Warning notice system This manual contains notices you have to

More information

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3.

SIMOCODE pro. Read me SIMOCODE ES. Introduction 1. Installation notes 2. Installation/License key/ Uninstallation 3. Introduction 1 Installation notes 2 SIMOCODE pro Installation/License key/ Uninstallation 3 Tips for use 4 Technical assistance 5 Readme Legal information Warning notice system This manual contains notices

More information

SINETPLAN Siemens Network Planner

SINETPLAN Siemens Network Planner Siemens Hardware SINETPLAN Operating Manual 07/2017 A5E37575946-AB Introduction 1 Getting Started 2 Installation 3 Graphical user interface 4 Importing projects from STEP 7 5 Importing projects from STEP

More information

SIMATIC. ET 200SP Digital input module DI 8x24VDC ST (6ES7131-6BF01-0BA0) Preface. Documentation guide. Product overview.

SIMATIC. ET 200SP Digital input module DI 8x24VDC ST (6ES7131-6BF01-0BA0) Preface. Documentation guide. Product overview. Preface Documentation guide 1 SIMATIC ET 200SP Digital input module DI 8x24VDC ST (6ES7131-6BF01-0BA0) Manual Product overview 2 Wiring up 3 Parameters/address space 4 Interrupts/diagnostics alarms 5 Technical

More information

SIMATIC. ET 200SP Interface module IM DP HF (6ES7155-6BA01-0CN0) Preface. Guide to documentation. Product overview.

SIMATIC. ET 200SP Interface module IM DP HF (6ES7155-6BA01-0CN0) Preface. Guide to documentation. Product overview. Preface Guide to documentation 1 SIMATIC ET 200SP Interface module IM 155-6 DP HF (6ES7155-6BA01-0CN0) Manual Product overview 2 Connecting 3 Parameters/address space 4 Interrupts, error messages, diagnostics

More information

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3

SIMATIC. Process control system PCS 7 PCS 7 - PC Configuration (V9.0 SP1) Security information 1. Preface 2. PC components of a PCS 7 system 3 Security information 1 Preface 2 SIMATIC Process control system PCS 7 Installation Manual PC components of a PCS 7 system 3 Hardware for PC stations 4 Installing PC stations 5 Appendices 6 Valid for PCS

More information

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual Class: RevisionInfo 1 Class: RevisionMaster 2 COMOS Platform Class documentation RevisionMaster_dll Programming Manual 03/2017 V10.2.1 A5E39859923-AA Legal information Warning notice system This manual

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 04/2007 A5E01119980-01

More information

CM PtP RS422/485 BA communication. module (6ES7540 1AB00 0AA0) SIMATIC. S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0)

CM PtP RS422/485 BA communication. module (6ES7540 1AB00 0AA0) SIMATIC. S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0) CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0) SIMATIC S7-1500/ET 200MP CM PtP RS422/485 BA communication module (6ES7540 1AB00 0AA0) Manual Preface Documentation guide 1 Product overview

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information. Industrial Controls SIMOCODE pro Preface 1 Product specific security Security information 2 information 3 Introduction 4 5 References 6 List of Abbreviations 7 10/2018 A5E36558134002A/RS-AB/002 Legal information

More information

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme Validity 1 Improvements in STEP 7 2 SIMATIC Improvements in WinCC 3 05/2017 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety,

More information

ST (6ES7522-1BH00-0AB0)

ST (6ES7522-1BH00-0AB0) SIMATIC S7-1500 Digital output module DQ 16x24VDC/0.5A ST (6ES7522-1BH00-0AB0) Manual Edition 07/2014 Answers for industry. DQ 16x24VDC/0.5A ST Digital Output Module (6ES7522-1BH00-0AB0) SIMATIC S7-1500/ET

More information

Optional package printer driver V1.4

Optional package printer driver V1.4 Security note 1 Validity 2 Supported HMI devices 3 Installation 4 Readme Transferring the Options 5 Setting up the printer driver 6 Legal information Warning notice system This manual contains notices

More information

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2

Primary Setup Tool (PST) SIMATIC NET. Industrial Ethernet / PROFINET Primary Setup Tool (PST) Preface. Description. Software installation 2 Preface Description 1 SIMATIC NET Industrial Ethernet / PROFINET Software installation 2 Functions 3 Configuration Manual 07/2014 C79000-G8976-C204-06 Legal information Warning notice system This manual

More information

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system

SIMATIC. Industrial PC Microsoft Windows 7. Safety instructions 1. Initial startup: Commissioning the operating. system Safety instructions 1 Initial startup: Commissioning the operating 2 system SIMATIC Industrial PC Operating Instructions Restoring the factory settings of the operating system and 3 partitions (Restore)

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

PN/CAN LINK Configuring the "CANopen manager" and "CANopen slave" operating modes TIA Portal V14, SIMATIC S7 https://support.industry.siemens.com/cs/ww/en/view/109751077 Siemens Industry Online Support

More information

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual Class documentation COMOSKDictionary COMOS Trademarks 1 General 2 KDictionary 3 Platform Class documentation COMOSKDictionary Programming Manual 04/2012 A5E03777026-01 Legal information Legal information

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET

Performance data abgn PCIe Minicard MPCIE-R1-ABGN-U3 SIMATIC NET Performance data 802.11abgn PCIe Minicard MPCIE-R1-ABGN-U3 Technical specifications 1 SIMATIC NET Industrial Wireless LAN Performance data 802.11abgn PCIe Minicard MPCIE-R1-ABGN-U3 Reference Manual 07/2014

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A AC24..230V/5A (6ES7132-4HB50-0AB0) SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Security information 1 Overview 2 SIMATIC Process control system SIMATIC BATCH Readme V9.0 (Online) Part A, Requirements and General Instructions 3 Part B, Installation 4 Part C, Special Features and Notes

More information

SIMATIC. S7-1500, ET 200MP, ET 200SP Counting, measurement and position detection. Preface. Documentation guide

SIMATIC. S7-1500, ET 200MP, ET 200SP Counting, measurement and position detection. Preface. Documentation guide Preface Documentation guide 1 SIMATIC S7-1500, ET 200MP, ET 200SP Counting, measurement and position detection Function Manual The basics of counting, measurement and position 2 detection Using the High_Speed_Counter

More information

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control Getting Started - Commissioning a CPU Introduction 1 31xC: Closed-loop control Preparation 2 SIMATIC S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control Learning units 3 Further Information

More information

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation SIMATIC NET PG/PC - Industrial Ethernet Operating Instructions 1 Preface 2 Description of the device 3 Software installation 4 Hardware installation 5 Configuration 6 Technical specifications A Approvals

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2 Options for Accessing Documentation 1 Documentation for the Planning Phase 2 SIMATIC Process Control System PCS 7 Documentation for the Realization Phase 3 Documentation on commissioning, operation, diagnostics

More information

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation

SINEMA Remote Connect - Client SIMATIC NET. Industrial Remote Communication SINEMA Remote Connect - Client. Preface. Requirements for operation Preface Requirements for operation 1 SIMATIC NET Industrial Remote Communication Installation and commissioning 2 Configuration 3 Operating Instructions 07/2015 C79000-G8976-C395-02 Legal information Warning

More information

ST (6ES7522-5HF00-0AB0)

ST (6ES7522-5HF00-0AB0) SIMATIC S7-1500 Digital output module DQ 8x230VAC/5A ST (6ES7522-5HF00-0AB0) Manual Edition 07/2014 Answers for industry. DQ 8x230VAC/5A ST Digital Output Module (6ES7522-5HF00-0AB0) SIMATIC S7-1500/ET

More information

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating.

SIMATIC. Industrial PC Microsoft Windows Embedded Standard 7. Safety instructions 1. Initial startup: Commissioning the operating. Safety instructions 1 Initial startup: Commissioning the operating 2 system SIMATIC Industrial PC Microsoft Windows Embedded Standard 7 Restoring the factory settings of the operating system and 3 partitions

More information

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3

SIMATIC. Process Control System PCS 7 SIMATIC Management Console (V9.0) Security information 1. Preface 2. Basics 3 Security information 1 Preface 2 SIMATIC Process Control System PCS 7 SIMATIC Management Console (V9.0) Operating Manual Basics 3 Installation of the Management Console 4 Operator control 5 Menus and dialog

More information