64-Bit PCI to Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS

Size: px
Start display at page:

Download "64-Bit PCI to Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS"

Transcription

1 64-Bit PCI to Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS Introduction These release notes contain late-breaking and supplemental information for the the Compaq StorageWorks 64-Bit PCI to Fibre Channel Host Bus Adapter for Tru64 UNIX and OpenVMS. This information is periodically updated and available on the World Wide Web at URL The 64-Bit PCI to Fibre Channel Host Bus Adapter (HBA) is a highperformance PCI option module that connects to devices attached through either a hub-based optical Fibre Channel arbitrated loop or a switch based optical Fibre Channel fabric. The HBA supports only short wave multi-mode connections. These release notes include all known issues or restrictions for using the HBA within a system configuration. This document is organized into four sections: Parts List Supported systems Verified device listing Restrictions

2 2 64-bit Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS Table 1 Parts List Part Number Digital Classic Revision Description DS-KGPSA-CA A 64-Bit PCI to Fibre Channel Host Bus Adapter AV-RLLUA-TE A Release notes for the KGPSA- CA (this document) AA-RKPDA-TE A 64-Bit PCI to Fibre Channel Adapter User Guide 3R-Q178A-3V B01 Warranty Addendum Software License EK-HSXSW-WC C01 Warranty Terms and Conditions

3 64-Bit PCI to Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS 3 Supported Systems Table 2 lists platforms and operating systems that have passed compatibility testing with the HBA as of the date on these release notes. Table 2 describes the Alpha server platforms with the associated number of adapters that are supported per operating system configuration. Refer to the Restrictions section in these release notes for known operating system and device restrictions. Table 2 Supported Alpha Server Platforms Tru64 Unix OpenVMS 1 FC-AL Switch Switch ALPHA SERVER SINGLE CLUSTER SINGLE CLUSTER SINGLE CLUSTER ES DS DS20E DS AS8200 AS8400 GS60/140 EV6 EV6/7 N/S N/S N/S N/S TIMA kit is required. See OpenVMS Restrictions section in this document for version information.

4 4 64-bit Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS Supported Storage and Interconnecting Devices The following matrix describes the associated components and their revisions that are qualified with the HBA. Table 3 Supported Storage and Interconnect Devices COMPONENT FW/Driver Version P/N DS-KGPSA-CA DD302a1.awc Resides on the HBA Unix Driver (4.0F) 1.12 BL13, NHD2 VMS Driver (7.2-1) NA VMS TIMA KIT 8 Port Switch OVMS721_FIBRECHAN_V B DS-DSGGA-AA B21 16 Port Switch DS-DSGGA-AB B21 8 Port Switch 16 Port Switch 2.03A DS-DSGGB-AA DS-DSGGB-AB RA8000/ESA12000 ACS ACS 8.5 Unix QB-65RAB-SA ACS OVMS QB-65RAC-SA ACS 8.5 continued

5 64-Bit PCI to Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS 5 Table 3 Supported Storage and Interconnect Devices continued COMPONENT Alpha Console 5.6 FW/Driver Version P/N 12-Port Hub N/A DS-HDGGB-AA B22 7-Port Hub N/A DS-SWXHB-X xxx SWL GBIC (IBM) N/A SWL GBIC (Vixel) N/A Optical Cables (connection from HBA to Hub or Switch) N/A BNGBX-xx (02,05,15,30,50) B2x (xx = length in meters) Configuration Information The following configuration information is valid across Tru64 UNIX and OpenVMS. Support for mixed HBA in the same host and B21 Maximum number of cascaded (serial) switches: 3 Maximum number of hops: 2 (between switches, 2 LWL GBICs, 10km max) Maximum cable length between switches: 500m for SWL, 10K LWL Support a mix of fibre channel switches in the same configuration Restrictions Beginning with DS-KGPSA-CA global restrictions, the remainder of this document contains the restrictions for each of the operating systems on which the adapter can be installed.

6 6 64-bit Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS DS-KGPSA-CA Restrictions The minimum Revision of DS-KGPSA-CA firmware for Alpha platforms all Operating Systems is dd302a1.awc. The minimum Revision of the KGPSA-CA adapter hardware is FC Rev B Maximum length of the OPTICAL cable from the DS-KGPSA-CA to a hub or switch is 500 meters short wave multi mode 50/125 micron Fibre Channel Cable. Tru64 UNIX Restrictions Tru64 UNIX restrictions include: The KGPSA driver for Tru64 UNIX is built into the operating system. Tru64 UNIX V4.0x does not support the installation of the Operating System on an RA8000 or ESA Tru64 UNIX 4.0F, BL13, NHD2 or greater supports adapters in Fibre Channel switch topologies and in Fibre Channel Arbitrated Loop topologies. Both KGPSA-BC and KGPSA-CA are supported. Cascaded switch support requires a Tru64 UNIX driver patch. Refer to Tru64 UNIX Driver and Console Software The HBA driver is built into the Tru64 UNIX operating systems and supported by Console software. For the supported versions of Tru64 UNIX operating systems and Console software, consult the HBA release notes included in this documentation package. Release notes are updated periodically and can be obtained from the Compaq website: Drill down through Services and Support to Adapter Support. See the documentation specific to your platform for detailed information on installing the appropriate operating system and Console software.

7 64-Bit PCI to Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS 7 WWIDMGR -SHOW ADAPTER / -SET ADAPTER Commands V5.6 SRM console and higher revisions have the capability of setting an HBA to run in arbitrated loop mode or in fabric (switch) mode. If an HBA in loop mode is connected to a switch, the results are unpredictable. The same is true for an HBA in fabric mode that is connected to a loop. By default, the console assumes a fabric topology. The SET ADAPTER command stores the selected topology into the NVRAM storage on the HBA. If the HBA is moved from one AlphaServer to another, this setting stays with the HBA. Console Revision V5.6 or greater supports the FCAL (loop) topology. A setting of loop is a valid setting in Console Revision V5.6, however, that setting prompts the console driver not to run. What this means is once the HBA has been set to loop topology, console commands such as show device or quick assign will not display any HBA s and their attached devices. Refer to the WWIDGR manual at the following location for detailed information on the SHOW ADAPTER and SET ADAPTER commands: NOTE: On some systems, such as the GS140, in order for the SHOW ADAPTER and SET ADAPTER commands to be accepted by the system, the console must first be set to diagnostic mode (set mode diag). While on other systems such as the DS10, DS20 and ES40 the set to diagnostic mode (set mode diag) is not required in order to enter the - SHOW ADAPTER and -SET ADAPTER commands. -SHOW ADAPTER Command P00>>>wwidmgr-show adapter The HBA configuration can be displayed with the command (see Figures 1 and 2): WWIDMGR -SHOW ADAPTER Item adapter WWN Cur. Topo Next Topo kgpsaa Nvram read failed [0] kgpsaa c921-0c22 fabric unavail kgpsab Nvram read failed [1] kgpsab c a loop unavail [9999] All of the above. Figure 1. SHOW ADAPTER with an unformatted NVRAM

8 8 64-bit Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS In Figure 1, note the warning message Nvram Read Failed. This indicates that the NVRAM on the HBA has not been initialized and formatted. This is expected and can be corrected by issuing a SET ADAPTER command as described in the next section. LP00>>>wwidmgr-show adapter Item adapter WWN Cur. Topo Next Topo [0] kgpsaa c921-05ab fabric fabric [1] kgpsab c921-0ce0 fabric fabric [9999] All of the above. Figure 2. SHOW ADAPTER display Figure 2 shows a display from WWIDMGR -SHOW ADAPTER where there are two HBAs in the system. See the following for a detailed look at a line item: [0] kgpsaa c921-05ab fabric fabric [0] Item Number. The bracketed value is used as a parameter to the item qualifier in the WWIDMGR -SET ADAPTER command. You can select which HBA to configure by its item number. An item number of 9999 selects all HBAs. Kgpsaa Adapter Mnemonic. Error messages and displays use this identifier c920-05ab WWN of the HBA. This value is used to identify the HBA to other nodes on the fibre channel link. Fabric Current Topology. This value is either fabric or loop. It indicates the mode in which the HBA is operating currently, during this WWIDMGR session. The current mode in which the HBA is running is not altered during a WWIDMGR session. Fabric Next Topology. This value can be fabric, loop, or unavail. It indicates the topology setting that is in the HBA s NVRAM. An unavail setting indicates the NVRAM is not formatted, a condition corrected by a SET ADAPTER command. A setting of fabric or loop indicates how the HBA is configured the next time the system is initialized.

9 64-Bit PCI to Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS 9 LP00>>>wwidmgr-show ada SET ADAPTER A WWIDMGR -SET ADAPTER command is used to format the HBA NVRAM and to configure an HBA to run on a loop or a fabric. The command format is: wwidmgr-set adapter -item<itemno> -topo<fabriciloop> where itemno is the bracketed value from the SHOW ADAPTER command. In Figure 3-3, you can change all HBA s from fabric to loop by specifying an itemno value of The init is shown at the end to emphasize that the setting in the running HBA is not changed until the next initialization. Item adapter WWN Cur. Topo Next Topo [0] kgpsaa c920-05ab fabric fabric [1] kgpsab c921-0ce0 fabric fabric [9999] All of the above LP00>>>wwidmgr-set adapter item 9999 topo loop LP00>>>wwidmgr-show ada Item adapter WWN Cur. Topo Next Topo [0] kgpsaa c920-05ab fabric loop [1] kgpsab c921-0ce0 fabric loop [9999] All of the above. LP00>>>init Figure 3. SET ADAPTER example OpenVMS Restrictions OpenVMS restrictions include: The DS-KGPSA-BC and the DS-KGPSA-CA driver for OpenVMS is built into the Operating System. The minimum revision of the operating system for the KGPSA-CA HBA is VMS OpenVMS only supports the DS-KGPSA-BC and DS-KGPSA-CA adapters in Fibre Channel switch topologies. The DS-KGPSA-BC and the DS-KGPSA-CA adapters require Alpha VMS V7.2-1 TIMA kit OVMS721_FIBRECHAN_V0200 Open VMS will not support the operation of the S3Trio video board and the DS-KGPSA-BC or DS-KGPSA-CA adapter in the same PCI bus.

10 10 64-bit Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS For large system configurations (many DS-KGPSA-CAs/devices and paths) the VMS install CD will not boot. It will hang if no DS-KGPSA- CAs are in the system; or it will crash (either INCONSTATE or IOMACHINECHK) if a DS-KGPSA-CA is installed in the system. The workaround is to perform a conversational boot (boot -fl 0,1) of the CD and at the sysboot prompt to increase the SYSGEN value of NPAGEVIR. The recommendation is to initially double the CD default of 8,388,608 Bytes. Rarely, on boots and reboots, a HBA s port does not come on line. The workaround is to unplug and then reseat the HBA s cable. Then run MC SYSMAN IO AUTO/LOG to bring the port on line. Using the SHOW DEV DG/MULTIPATH command is a quick way to determine if all of the paths are there after a boot. OpenVMS plans to provide a TIMA kit to solve this problem. "SHOW DEVICE may fail with a "virtual address space full" error on systems with more than 2400 Unit Control Blocks (UCBs). In multipath SCSI and FC configurations, there is a UCB for each path from the host to every storage device. Note that any procedure that calls SHOW DEVICE, such as CLUSTER_CONFIG, will also experience this problem. OpenVMS plans to provide a TIMA kit to solve this problem. Please refer to the web site for availability. In the meantime, these problems can be avoided by reducing the number of UCBs in the system, by removing host adapters or storage devices, or disconnecting redundant FC paths." Upgrading an OpenVMS System to V7.2-1 This procedure is for existing OpenVMS systems being upgraded to V7.2-1 that did not have any DS-KGPSA-BC adapters installed and you are now adding DS-KGPSA-CA Adapters. NOTE: This procedure is not be required for upgrading to VMS if there are existing DS-KGPSA-BC adapters in the system with a path to the intended system disk. 1. Boot the V7.2-1 installation CD and create a V7.2-1 system disk. 2. Boot the new system disk and install the FC TIMA kit images. 3. Install the DS-KGPAS-CA adapter into the system. Refer to the user guide for the installation procedure for the DS-KGPSA-CA Adapter. 4. Boot the system from the non-fc system disk. 5. For a FC system disk, perform an image backup from the non-fc system disk to the targeted FC system.

11

12 12 64-bit Fibre Channel Host Bus Adapter Release Notes for Tru64 UNIX and OpenVMS NOTICE The information in this document is subject to change without notice. COMPAQ COMPUTER CORPORATION SHALL NOT BE LIABLE FOR TECHNICAL OR EDITORIAL ERRORS OR OMISSIONS CONTAINED HEREIN; NOR FOR THE INCIDENTAL OR CONSEQENTIAL DAMAGES RESULTING FROM THE FURNISHING, PERFORMANCE, OR USE OF THIS MATERIAL. This document contains information protected by copyright. No part of this document may be photocopied or reproduced in any form without prior written consent from Compaq Computer Corporation. Product names mentioned herein are trademarks and/or registered trademarks of their respective companies Compaq Computer Corporation. All rights reserved. Printed in the U.S..A. First Edition (March 2000) Part Number AV-RLLUA-TE

AlphaServer DS10 V7.2 Console Firmware Release Notes

AlphaServer DS10 V7.2 Console Firmware Release Notes AlphaServer DS10 V7.2 Console Firmware Release Notes Hewlett-Packard Company June 2006 The information in this publication is subject to change without notice. Copyright 2004-2006 Hewlett-Packard Company

More information

Configuring and Installing Fibre Channel (FC) Storage on OpenVMS. Fibre Channel (FC) Storage on OpenVMS

Configuring and Installing Fibre Channel (FC) Storage on OpenVMS. Fibre Channel (FC) Storage on OpenVMS Configuring and Installing Vortrag 3C02 Manfred.Kaser@compaq.com Compaq Computer München Topics of Discussion Websites of interest, Documentation FC and Multipath Support Description FC Storage System

More information

HP StorageWorks Disk Array XP operating system configuration guide

HP StorageWorks Disk Array XP operating system configuration guide OpenVMS HP StorageWorks Disk Array XP operating system configuration guide XP48 XP128 XP512 XP1024 XP12000 fourth edition (November 2004) part number: A5951-96132 This guide describes the requirements

More information

HP StorageWorks Continuous Access EVA 2.1 release notes update

HP StorageWorks Continuous Access EVA 2.1 release notes update HP StorageWorks Continuous Access EVA 2.1 release notes update Part number: T3687-96038 Third edition: August 2005 Legal and notice information Copyright 2005 Hewlett-Packard Development Company, L.P.

More information

Configuration Guide for HP OpenVMS Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM

Configuration Guide for HP OpenVMS Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM Configuration Guide for HP OpenVMS Host Attachment Hitachi Virtual Storage Platform Hitachi Universal Storage Platform V/VM FASTFIND LINKS Document Organization Product Version Getting Help Contents MK-96RD653-05

More information

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide Part number: 5697-5263 First edition: May 2005 Legal and notice information Copyright

More information

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide Order Number: EK-H8253-IN. A01 Compaq Computer Corporation Maynard, Massachusetts First Printing, November 1998 The information

More information

Rackable 24 Slot Expansion B21 See text for FC hubs, FC switches, platform software, host adapters, disks and options for complete solutions.

Rackable 24 Slot Expansion B21 See text for FC hubs, FC switches, platform software, host adapters, disks and options for complete solutions. M ODELS RA8000 Fibre Channel Fibre Channel Storage solution with industry-leading storage area network (SAN) support uses arbitrated loop (FC-AL) and the latest switched fabric (FC- SW) technology. It

More information

Firmware Update Instructions

Firmware Update Instructions Firmware Update Instructions Flexor A264 and Flexor A164 SBC March 2002 This manual contains instructions for updating system firmware for the Flexor A264 and Flexor A164 SBC. Historical revision information

More information

HP StorageWorks Enterprise Virtual Array

HP StorageWorks Enterprise Virtual Array Release Notes HP StorageWorks Enterprise Virtual Array Product Version: v3.025 First Edition March, 2005 Part Number: 5697 5237 *5697-5237* This document contains the most recent product information about

More information

FIBER CHANNEL TECH NOTE TECHNICAL AND INFORMATIONAL BN

FIBER CHANNEL TECH NOTE TECHNICAL AND INFORMATIONAL BN TECHNICAL AND INFORMATIONAL BN-0014-02 Fiber Channel Tech Note BN-0014-02 (18-Feb-2019)) 2019 AVT/Vere vtalpha and vtvax are marketed jointly by AVT and Vere Technologies LLC BN-0014-02 Page 2 of 14 Table

More information

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations

Configuring the HP StorageWorks Modular Smart Array 1000 and 1500cs for external boot with Novell NetWare New Installations Technical Note Revised October 2006 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Configuring the StorageWorks MSA1000 and MSA1500cs for External Boot with NetWare Considerations...3

More information

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes Part number: AA-RVGWG-TE Sixth edition: July 2006 Legal and notice information

More information

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005) MSA1500cs ReleaseNotes hp StorageWorks Modular Smart Array 1500 cs Release Notes Third Edition (February 2005) Publication of the third edition of this document coincides with the release of MSA1500 cs

More information

DIGITAL SNA APPC/LU6.2 Programming Interface for OpenVMS Installation

DIGITAL SNA APPC/LU6.2 Programming Interface for OpenVMS Installation DIGITAL SNA APPC/LU6.2 Programming Interface for OpenVMS Installation Part Number: AA-EV68G-TE November 1998 This document describes how to install the DIGITAL SNA APPC/LU6.2 Programming Interface for

More information

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for SGI IRIX

Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for SGI IRIX Quick Setup Guide RAID Array 8000/ESA12000 Fibre Channel Storage Subsystem for SGI IRIX AA RFBHA TE 387398-001 Before You Begin In this Quick Setup Guide we tell you how to create an initial hardware configuration

More information

QuickSpecs. Compaq ProLiant Clusters for UnixWare 7 - U/100 Kit M ODELS S TANDARD FEATURES C OMPONENTS. Retired

QuickSpecs. Compaq ProLiant Clusters for UnixWare 7 - U/100 Kit M ODELS S TANDARD FEATURES C OMPONENTS. Retired M ODELS for UnixWare U/100 Kit 155370-B21 The U/100 Kit is designed to enable a two-node, highly available cluster solution. The kit offers cluster capability on many of Compaq s entry, midrange, and high-end

More information

QuickSpecs. StorageWorks SAN Switch 2/8-EL by Compaq. Overview

QuickSpecs. StorageWorks SAN Switch 2/8-EL by Compaq. Overview Overview The StorageWorks San Switch 2/8-EL is the next generation entry level 8 port fibre channel SAN fabric switch featuring 2Gb transfer speed and the optional ability to trunk or aggregate the throughput

More information

HP StorageWorks Enterprise Virtual Array

HP StorageWorks Enterprise Virtual Array Release Notes HP StorageWorks Enterprise Virtual Array Product Version: v3.020 Fourth Edition August, 2004 Part Number: T3030 98501 This document contains the most recent product information about the

More information

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment November 2000 Copyright 2000 EMC Corporation. All rights reserved. No part of this publication may be reproduced

More information

Release Notes HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software Version 8.7 for Windows NT and Windows 2000

Release Notes HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software Version 8.7 for Windows NT and Windows 2000 hp StorageWorks Release Notes HSG80 Enterprise/Modular Storage RAID Array Fibre Channel Solution Software Version 8.7 for Windows NT and Windows 2000 Part Number: AA-RH0QK-TE Tenth Edition (January 2003)

More information

AlphaServer GS60/140 and 8200/8400 Release Notes

AlphaServer GS60/140 and 8200/8400 Release Notes AlphaServer GS60/140 and 8200/8400 Release Notes Part Number: EK T8284 RN. H01 November 1999 This document supplies the hardware release notes for the AlphaServer GS60/140 and 8200/8400 systems and is

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CD-TE Third edition: August 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P. Hewlett-Packard

More information

QuickSpecs. SANworks Data Replication Manager HPUX By Compaq M ODELS

QuickSpecs. SANworks Data Replication Manager HPUX By Compaq M ODELS M ODELS SANworks Data Replication Manager by Compaq SANworks Data Replication Manager (DRM) is fibre channel controller-based data replication software for disaster tolerance, recovery and data movement

More information

Upgrading the MSA1000 for Enhanced Features

Upgrading the MSA1000 for Enhanced Features White Paper December 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the MSA1000 Enhancements...1 Prerequisites...3 Environmental Monitoring Unit (EMU) issue:...3

More information

QuickSpecs. StorageWorks Fibre Channel SAN Switch 16-EL by Compaq M ODELS O VERVIEW

QuickSpecs. StorageWorks Fibre Channel SAN Switch 16-EL by Compaq M ODELS O VERVIEW M ODELS Fibre Channel Switch 16-EL 212776-B21 253740-001 Fibre Channel Switch 16-EL - Bundle What is New This model is the only Compaq Switch that comes with a set of rack mounting rails, allowing the

More information

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID

Target Environments The Smart Array 6i Controller offers superior investment protection to the following environments: Non-RAID Overview The Smart Array 6i controller is an Ultra320 intelligent array controller for entry-level, hardware-based fault tolerance for protection of OS, applications, and logs. Most models have one internal-only

More information

Software Product Description

Software Product Description Software Product Description PRODUCT NAME: Compaq DECnet SNA Gateway for DESCRIPTION Compaq DECnet SNA Gateway for Synchronous Transport (DECnet SNA Gateway-ST) is a member of the DECnet SNA Gateway product

More information

Microsoft Windows Server 2008 On Integrity Servers Overview

Microsoft Windows Server 2008 On Integrity Servers Overview Overview The HP Integrity servers based on Intel Itanium architecture provide one of the most reliable and scalable platforms currently available for mission-critical Windows Server deployments. Windows

More information

Storage Area Networks SAN. Shane Healy

Storage Area Networks SAN. Shane Healy Storage Area Networks SAN Shane Healy Objective/Agenda Provide a basic overview of what Storage Area Networks (SAN) are, what the constituent components are, and how these components fit together to deliver

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CE-TE Third edition: December 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P.

More information

HP StorageWorks Emulex host bus adapters for x86 and x64 Linux and Windows systems release notes

HP StorageWorks Emulex host bus adapters for x86 and x64 Linux and Windows systems release notes HP StorageWorks Emulex host bus adapters for x86 and x64 Linux and Windows systems release notes Part number: AV-RUPXS-TE Eighteenth edition: September 2006 Description These release notes contain information

More information

QuickSpecs. HP SANworks Storage Resource Manager. Overview. Model HP SANworks Storage Resource Manager v4.0b Enterprise Edition.

QuickSpecs. HP SANworks Storage Resource Manager. Overview. Model HP SANworks Storage Resource Manager v4.0b Enterprise Edition. Overview Model v4.0b Enterprise Edition Introduction Storage Resource Manager (SRM) is web-based software for HP-UX, Windows 2000, Windows NT, Novell NetWare, Tru64 UNIX, OpenVMS, Sun Solaris, IBM AIX,

More information

QuickSpecs. Overview. hp AlphaServer GS160 (1224 MHz) At A Glance

QuickSpecs. Overview. hp AlphaServer GS160 (1224 MHz) At A Glance Overview At A Glance AlphaServer GS160 systems include: One 1224-MHz CPU module; up to 16 (upgradeable to 32) 1224-MHz Alpha 21264 processors supported Optional HP Capacity on Demand (CoD) SMP processors

More information

AlphaServer ES40 Release Notes

AlphaServer ES40 Release Notes AlphaServer ES40 Release Notes Part Number: EK ES240 RN C01 October 1999 This document supplies the hardware release notes for the Compaq AlphaServer ES40 system and is intended for anyone operating, managing,

More information

Tips for Setting Up SANs for HP OpenVMS

Tips for Setting Up SANs for HP OpenVMS Tips for Setting Up SANs for HP OpenVMS Wes Lee Roberts Technical Account Manager - OpenVMS Ambassador HP Services - OpenVMS Platinum Support 2004 Hewlett-Packard Development Company, L.P. The information

More information

Configuring the MSA1000 for Linux or NetWare Environments

Configuring the MSA1000 for Linux or NetWare Environments White Paper September 2002 Prepared by: Network Storage Solutions Hewlett Packard Company Contents Benefits of the new firmware for the MSA1000...1 Prerequisites...3 Firmware Upgrades:...3 Environmental

More information

StorageWorks Dual Channel 4Gb, PCI-X-to-Fibre Channel Host Bus Adapter for Windows and Linux (Emulex LP11002)

StorageWorks Dual Channel 4Gb, PCI-X-to-Fibre Channel Host Bus Adapter for Windows and Linux (Emulex LP11002) Models FC2143 4Gb PCI-X 2.0 HBA FC2243 Dual 4Gb PCI-X 2.0 HBA FC1143 4Gb PCI-X 2.0 HBA FC1243 Dual 4Gb PCI-X 2.0 HBA StorageWorks 4Gb, PCI-X-to-Fibre Host Bus Adapter for Windows and Linux. (Emulex LP1150)

More information

HP AlphaServer systems comparison chart for your mission-critical applications

HP AlphaServer systems comparison chart for your mission-critical applications HP AlphaServer systems comparison chart for your mission-critical applications Building on more than a decade of technology leadership, HP AlphaServer systems are synchronized with today s fast-paced and

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

QuickSpecs. ProLiant Cluster F500 for the Enterprise SAN. Overview. Retired

QuickSpecs. ProLiant Cluster F500 for the Enterprise SAN. Overview. Retired Overview The is designed to assist in simplifying the configuration of cluster solutions that provide the highest level of data and applications availability in the Windows Operating System environment

More information

Compaq PowerStorm 300/AGP and 300/PCI Graphics Options Installation Guide

Compaq PowerStorm 300/AGP and 300/PCI Graphics Options Installation Guide Compaq PowerStorm 300/AGP and 300/PCI Graphics Options Installation Guide Part Number: EK-PBXAC-IN. A01/330430-001 September 1998 This guide describes the installation of the Compaq PowerStorm 300/AGP

More information

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes Part number: AA RV22F TE Sixth edition: August 2006 Legal and notice information Copyright

More information

QuickSpecs. Models ProLiant Cluster F200 for the Entry Level SAN. Overview

QuickSpecs. Models ProLiant Cluster F200 for the Entry Level SAN. Overview Overview The is designed to assist in simplifying the configuration of cluster solutions that provide high levels of data and applications availability in the Microsoft Windows Operating System environment

More information

HP StorageWorks Modular Smart Array 1500 cs application note

HP StorageWorks Modular Smart Array 1500 cs application note HP StorageWorks Modular Smart Array 1500 cs application note Migrating to active/active controllers in HP-UX environments *400677-001* *400677 001* Part number: 400677 001 First edition: September 2005

More information

hp AlphaServer GS1280/ES80/ES47 V7.3 Console Firmware Release Notes

hp AlphaServer GS1280/ES80/ES47 V7.3 Console Firmware Release Notes Updated: July 29, 2008 hp AlphaServer GS1280/ES80/ES47 V7.3 Console Firmware Release Notes This document contains firmware enhancements and update procedures. Start with Read Me First. Hewlett-Packard

More information

Symantec NetBackup Appliance Fibre Channel Guide

Symantec NetBackup Appliance Fibre Channel Guide Symantec NetBackup Appliance Fibre Channel Guide Release 2.6.1.2 NetBackup 52xx and 5330 Symantec NetBackup Appliance Fibre Channel Guide Documentation version: 2.6.1.2 Legal Notice Copyright 2015 Symantec

More information

Retired. Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities:

Retired. Windows Server 2008 R2 for Itanium-Based Systems offers the following high-end features and capabilities: Overview NOTE: HP no longer sells Microsoft Windows Server 2008/2008 R2 on Integrity servers. HP will continue to support Microsoft Windows Server 2008/2008 R2 until Microsoft's end of mainstream support

More information

RAID-01 (ciss) B Mass Storage Driver Release Notes

RAID-01 (ciss) B Mass Storage Driver Release Notes RAID-01 (ciss) B.11.31.1705 Mass Storage Driver Release Notes HP-UX 11i v3 Abstract This document contains specific information that is intended for users of this HPE product. Part Number: Published:

More information

Upgrading From an HSZ70 to an HSG80 Array Controller

Upgrading From an HSZ70 to an HSG80 Array Controller Service Guide This guide provides a procedure for upgrading an HSZ70 Array Controller to an HSG80 ACS Version 8.3 Array Controller. It contains a roadmap, twelve sections with step-by-step instructions,

More information

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter Overview The HP (HBA) provides customers with the flexibility and speed they have come to expect from HP. The 64-bit/133-MHz Dual Channel Ultra320 SCSI HBA is ideal for HP tape arrays and larger non- RAID

More information

AlphaServer DS25 Console Firmware Release Notes V7.3

AlphaServer DS25 Console Firmware Release Notes V7.3 Revised: April 17, 2008 AlphaServer DS25 Console Firmware Release Notes V7.3 This document contains firmware enhancements and update procedures. Start with Read Me First Hewlett-Packard Company The information

More information

Release Notes P/N REV A03 January 3, 2006

Release Notes P/N REV A03 January 3, 2006 Sun StorEdge Traffic Manager for CLARiiON Release Notes P/N 300-002-978 REV A03 January 3, 2006 These release notes contain supplemental information about Sun StorEdge Traffic Manager for CLARiiON storage

More information

hp StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x

hp StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Release Notes hp StorageWorks HSG60 and HSG80 Controller and HSx80 Cache Module Replacement Procedures for Array Controller Software V8.7x-x Product Version: V8.7, V8.7-1, V8.7-2, V8.7-3 First Edition

More information

DtS Data Migration to the MSA1000

DtS Data Migration to the MSA1000 White Paper September 2002 Document Number Prepared by: Network Storage Solutions Hewlett Packard Company Contents Migrating Data from Smart Array controllers and RA4100 controllers...3 Installation Notes

More information

Q-VET Read Me. V7.9 for OpenVMS 7.3 V8.6 for OpenVMS 8.x V8.6 for Tru64Unix

Q-VET Read Me. V7.9 for OpenVMS 7.3 V8.6 for OpenVMS 8.x V8.6 for Tru64Unix Q-VET Read Me V7.9 for OpenVMS 7.3 V8.6 for OpenVMS 8.x V8.6 for Tru64Unix Q-Vet is included on the Alpha Systems Firmware Update CD for use by authorized Hewlett-Packard Service Personnel and Service

More information

QuickSpecs. Models HP SC11Xe Host Bus Adapter B21. HP SC11Xe Host Bus Adapter. Overview

QuickSpecs. Models HP SC11Xe Host Bus Adapter B21. HP SC11Xe Host Bus Adapter. Overview Overview The provides customers with the flexibility and speed they have come to expect from HP. This HBA is ideal for HP tape customers needing to attach Ultra320 tape backup devices on servers using

More information

Release Notes P/N Rev A02

Release Notes P/N Rev A02 EMC PowerPath for Windows Version 4.6 and Point Releases Release Notes P/N 300-003-931 Rev A02 November 27, 2006 These release notes contain information about features, system requirements, known problems,

More information

QuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired

QuickSpecs. Useful Web Sites For additional information, see the following web sites: Linux Operating System. Overview. Retired Overview NOTE: HP no longer sells RHEL and SLES on Integrity servers. HP will continue to support RHEL 5 on Integrity servers until Red Hat's end of support life date for RHEL 5 (March 31st, 2017). HP

More information

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-0025 Third edition: July 2009 Legal and notice information Copyright

More information

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems Application Notes HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems Product Version: 8.00 Second Edition (January 2005) Part Number: AA RVGWC TE This

More information

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide

Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Mac OS X Fibre Channel connectivity to the HP StorageWorks Enterprise Virtual Array storage system configuration guide Part number: 5697-7272 First edition: December 2007 Legal and notice information Copyright

More information

AlphaServer DS25 System Technical Summary

AlphaServer DS25 System Technical Summary AlphaServer DS25 System Technical Summary Contents HP AlphaServer DS25 Systems 1 System Overview 1 Features and Benefits 1 Third-Generation Alpha Chip 2 Chip Operation 2 Alpha 21264C Features 2 Processor

More information

HP Serviceguard Solutions Storage Support Matrix (HPUX) Jan 13, 2015, Ver 02.60

HP Serviceguard Solutions Storage Support Matrix (HPUX) Jan 13, 2015, Ver 02.60 HP Serviceguard Solutions Storage Support Matrix (HPUX) Jan 13, 2015, Ver 02.60 TE: Please refer to http://www.hp.com/softwarereleases/releases-media2/ for details on Product Support Lifecycle information.

More information

Software Product Description

Software Product Description Software Product Description PRODUCT NAME: HP Distributed Queuing Service for OpenVMS SPD 28.80.07 Important: Please read the HP Software Technical Support section before you proceed further. DESCRIPTION

More information

HP MSA Family Installation and Startup Service

HP MSA Family Installation and Startup Service Technical data HP MSA Family Installation and HP Services Service benefits Allows your IT resources to stay focused on their core tasks and priorities Reduces implementation time, impact, and risk to your

More information

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter

QuickSpecs. Models 64-Bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter B bit/133-MHz Dual Channel Ultra320 SCSI host bus adapter Overview The HP (HBA) provides customers with the flexibility and speed they have come to expect from HP. The 64-bit/133-MHz Dual Channel Ultra320 SCSI HBA is ideal for HP tape arrays and larger non- RAID

More information

Compaq AlphaServer DS10L Systems. Technical Summary

Compaq AlphaServer DS10L Systems. Technical Summary Compaq AlphaServer DS10L Systems Technical Summary Contents 1 System Overview Features and Benefits 2 Third-Generation Alpha Chip Chip Operation Alpha 21264 Features 3 Architecture System Block Diagram

More information

HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes

HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes Part Number: 504224-011R Published: November 2015 Edition: 12 Copyright 2009, 2015 Hewlett Packard Enterprise Development LP The information

More information

QuickSpecs. HP 12/24-GB DAT Drive. Overview. Models Feature List. Customer Benefits. Key Features. Retired

QuickSpecs. HP 12/24-GB DAT Drive. Overview. Models Feature List. Customer Benefits. Key Features. Retired Overview DAT tape drive that utilizes DDS-3 technology to perform up to 1.2 MB/sec or 4.2GB/hr (native); a new automatic head cleaning system reduces the need for cleaning; protects servers up to 24GB

More information

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service

HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service HP Services Technical data The HP StorageWorks MSA/P2000 Family Disk Array Installation and Startup Service provides the necessary

More information

Compaq AlphaServer ES40 Systems. Technical Summary

Compaq AlphaServer ES40 Systems. Technical Summary Compaq AlphaServer ES40 Systems Technical Summary Contents System Overview 1 Features and Benefits 2 Third-Generation Alpha Chip 2 Chip Operation Alpha 21264 Features Model Variants 3 CPU Upgrades 3 System

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

HP StorageWorks Partitioning in an EBS Environment Implementation Guide

HP StorageWorks Partitioning in an EBS Environment Implementation Guide HP StorageWorks Partitioning in an EBS Environment Implementation Guide Part number: 381448-002 First edition: November 2004 Copyright 2004 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company

More information

QuickSpecs. Overview. hp AlphaServer GS160 (1001 MHz) At A Glance

QuickSpecs. Overview. hp AlphaServer GS160 (1001 MHz) At A Glance Overview At A Glance AlphaServer GS160 systems include: One 1001-MHz CPU module; up to 16 (upgradeable to 32) 1001- MHz Alpha 21264 processors supported Optional Compaq Capacity on Demand (CCoD) SMP processors

More information

OpenVMS. OpenVMS Alpha to Integrity Transition Module V1.2. OpenVMS Industry Standard 64 (OpenVMS I64) OpenVMS Alpha OpenVMS I64 OpenVMS Alpha

OpenVMS. OpenVMS Alpha to Integrity Transition Module V1.2. OpenVMS Industry Standard 64 (OpenVMS I64) OpenVMS Alpha OpenVMS I64 OpenVMS Alpha OpenVMS Alpha to Integrity Transition Module V1.2 OpenVMS OpenVMS Industry Standard 64 (OpenVMS I64) OpenVMS Alpha OpenVMS I64 OpenVMS Alpha OpenVMS Alpha HP Integrity OpenVMS Alpha Integrity OpenVMS Alpha

More information

Copyright International Business Machines Corporation 2008, 2009, 2010, 2011, 2012, 2013 All rights reserved.

Copyright International Business Machines Corporation 2008, 2009, 2010, 2011, 2012, 2013 All rights reserved. IBM SystemStorage SAN24B-4 Express IBM SystemStorage SAN40B-4 IBM SystemStorage SAN80B-4 IBM SystemStorage SAN48B-5 IBM SystemNetworking SAN24B-5 IMPORTANT SAN b type interop documents will be transitioning

More information

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX

ETERNUS Disk storage systems Server Connection Guide (Fibre Channel) for VMware ESX Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

Veritas NetBackup Appliance Fibre Channel Guide

Veritas NetBackup Appliance Fibre Channel Guide Veritas NetBackup Appliance Fibre Channel Guide Release 3.1 and 3.1.1 NetBackup 52xx and 53xx Veritas NetBackup Appliance Fibre Channel Guide Legal Notice Copyright 2018 Veritas Technologies LLC. All rights

More information

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information... Installation Checklist HP ProLiant Cluster F500 for Enterprise Virtual Array 4000/6000/8000 using Microsoft Windows Server 2003, Enterprise Edition Stretch Cluster May 2005 Table of Contents ProLiant Cluster

More information

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions Hardware Announcement February 17, 2003 IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions Overview The IBM TotalStorage FAStT900 Storage Server expands the family

More information

Over 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons:

Over 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons: Overview The provides modular multi-protocol SAN designs with increased scalability, stability and ROI on storage infrastructure. Over 70% of servers within a data center are not connected to Fibre Channel

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

Table of contents. OpenVMS scalability with Oracle Rdb. Scalability achieved through performance tuning.

Table of contents. OpenVMS scalability with Oracle Rdb. Scalability achieved through performance tuning. OpenVMS scalability with Oracle Rdb Scalability achieved through performance tuning. Table of contents Abstract..........................................................2 From technical achievement to

More information

Veritas NetBackup Appliance Fibre Channel Guide

Veritas NetBackup Appliance Fibre Channel Guide Veritas NetBackup Appliance Fibre Channel Guide Release 3.1 and 3.1.1 NetBackup 52xx and 53xx Veritas NetBackup Appliance Fibre Channel Guide Legal Notice Copyright 2018 Veritas Technologies LLC. All rights

More information

Rev.1/31/00 A. Operating System: Windows NT 4.0 Software Version: DECevent NT 4.1

Rev.1/31/00 A. Operating System: Windows NT 4.0 Software Version: DECevent NT 4.1 Title Page DECevent NT is an event management utility that analyzes and translates Windows NT system events. DECevent NT translates events into readable text, analyzes them to determine the cause, and

More information

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A.

Installing the A4505A PCI Module Upgrade. HP Part No. A Edition E0297 Printed in U.S.A. Installing the A4505A PCI Module Upgrade HP Part No. A4500-90603 Edition E0297 Printed in U.S.A. Hewlett-Packard Co. 1997 Printing History First Printing: February 1997 UNIX is a registered trademark in

More information

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A HP StorageWorks Performance Advisor Installation Guide Version 1.7A notice Copyright 2002-2004 Hewlett-Packard Development Company, L.P. Edition 0402 Part Number B9369-96068 Hewlett-Packard Company makes

More information

Veritas NetBackup SAN Client and Fibre Transport Guide

Veritas NetBackup SAN Client and Fibre Transport Guide Veritas NetBackup SAN Client and Fibre Transport Guide UNIX, Windows, Linux Release 8.1 Veritas NetBackup SAN Client and Fibre Transport Guide Last updated: 2017-09-25 Legal Notice Copyright 2017 Veritas

More information

Compaq AlphaServer DS10 Systems. Technical Summary

Compaq AlphaServer DS10 Systems. Technical Summary Compaq AlphaServer DS0 Systems Technical Summary Contents System Overview Features and Benefits 2 Third-Generation Alpha Chip Chip Operation Alpha 2264 Features 3 Architecture System Block Diagram 4 System

More information

Virtual Recovery Assistant user s guide

Virtual Recovery Assistant user s guide Virtual Recovery Assistant user s guide Part number: T2558-96323 Second edition: March 2009 Copyright 2009 Hewlett-Packard Development Company, L.P. Hewlett-Packard Company makes no warranty of any kind

More information

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide

Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide Emulex 8Gb Fibre Channel Single-port and Dual-port HBAs for IBM System x IBM System x at-a-glance guide Streamlined installation and management, plus unrivaled scalability and industry-leading virtualization

More information

HP OpenVMS Version 8.4 Upgrade and Installation Manual

HP OpenVMS Version 8.4 Upgrade and Installation Manual HP OpenVMS Version 8.4 Upgrade and Installation Manual HP Part Number: BA322-90087 Published: June 2010 Copyright 2010 Hewlett-Packard Development Company, L.P Legal Notice Confidential computer software.

More information

hp StorageWorks Using the QLogic Driver for Single-path or Multi-path Failover Mode on Linux Systems

hp StorageWorks Using the QLogic Driver for Single-path or Multi-path Failover Mode on Linux Systems Application Notes hp StorageWorks Using the QLogic 7.00.03 Driver for Single-path or Multi-path Failover Mode on Linux Systems Product Version: 7.00.03 First Edition (May 2004) Part Number: AA RVGWA TE

More information

EXAMGOOD QUESTION & ANSWER. Accurate study guides High passing rate! Exam Good provides update free of charge in one year!

EXAMGOOD QUESTION & ANSWER. Accurate study guides High passing rate! Exam Good provides update free of charge in one year! EXAMGOOD QUESTION & ANSWER Exam Good provides update free of charge in one year! Accurate study guides High passing rate! http://www.examgood.com Exam : NS0-210 Title : Network Appliance FAS900 Pre-Sales

More information

HP Supporting the HP ProLiant Storage Server Product Family.

HP Supporting the HP ProLiant Storage Server Product Family. HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication

More information

ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations. Configurations

ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations. Configurations Overview ProLiant DL F100 Integrated Cluster Solutions and Non-Integrated Cluster Bundle Configurations 1. MSA1000 6. Fibre Channel Interconnect #1 and #2 2. Smart Array Controller 7. Ethernet "HeartBeat"

More information

Veritas NetBackup Appliance Fibre Channel Guide

Veritas NetBackup Appliance Fibre Channel Guide Veritas NetBackup Appliance Fibre Channel Guide Release 2.7.3 NetBackup 52xx and 5330 Document Revision 1 Veritas NetBackup Appliance Fibre Channel Guide Release 2.7.3 - Document Revision 1 Legal Notice

More information

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide

HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide HPE VMware ESXi and vsphere 5.x, 6.x and Updates Getting Started Guide Abstract This guide is intended to provide setup information for HPE VMware ESXi and vsphere. Part Number: 818330-003 Published: April

More information

QuickSpecs. Compaq Smart Array 431 Controller M ODELS

QuickSpecs. Compaq Smart Array 431 Controller M ODELS M ODELS Smart Array 431 Controller 127695-B21 127695-291(Japan) Data Compatibility Software Consistency Wide Ultra3 SCSI 64-bit Architecture 64-bit PCI Bus Design Single internal/external SCSI channel

More information