Radnoti. Radnoti. Radnoti. Precise digitally controlled temperature. Illuminated chamber improves sample viewing

Size: px
Start display at page:

Download "Radnoti. Radnoti. Radnoti. Precise digitally controlled temperature. Illuminated chamber improves sample viewing"

Transcription

1 Radnoti Myography Systems Precise digitally controlled temperature Illuminated chamber improves sample viewing Featuring an ergonomically designed sliding wrist rest Modular designed allowing for easy reconfiguration Radnoti Four Channel Myography System 4 Radnoti Single Channel Myography System 1 Designed for researchers performing contractile force studies on small ring samples with sizes ranging from 60 um to over 1 mm diameter that include mouse aortic rings and small intestinal ring samples down to micro-vessel preparation, such as mesenteric arteries. Radnoti 2007

2 no Radnoti 4 Four Channel Myography System Radnoti M series Myograph systems and components are true to the commitment of excellence and quality found in all Radnoti products. Available as the M 4 four channel and M 1 single channel Myograph system configurations. Radnoti 1 Single Channel Myography System

3 Precision Fabrication Using precision fabricated micro vessel support brackets, the system accommodates lumen diameters down to 60μm and segment lengths up to 3mm. For samples with lumen diameters of 1mm or more, the standard Radnoti Tissue Organ Bath systems are recommended. To mount the vessel segment, two individual parallel wires are passed through the sample lumen and attached to the micro vessel support brackets. Each vessel support bracket incorporates a micro groove on the Radno face to aid in maintaining the wire position when mounting. One bracket is connected to a precision 0 0.5gm capacitance type isometric force transducer (switchable to 0-5 gm and also available in 0-2 gm/0-20 gm configurations) that provides a true isometric measurement, i.e. less than 12.5μm deflection at 0.5gm force, which is critical when working with small vessel samples. The opposing Transducer Safety Lock An added feature is a safety lock for the ultra sensitive force transducer. The researcher is able to disable the movement of the micro vessel support bracket in a manner that protects the transducer. support bracket is connected to a precision micrometer controlling the X axis movement, with Y and minor Z axis positioning controls conveniently positioned on the Myograph chamber, allowing for precise alignment of the micro vessel support brackets. The wires are then anchored via a locking screw on each of the brackets. The locking screws feature a small bushing that is incorporated under the screw head greatly improving capture of the support wire. A pre-load tension is then applied via adjustment of the X axis micrometer. The researcher is able to disable the movement of the micro vessel support bracket in a manner that protects the transducer. The researcher is able to focus on mounting the sample with less worry about damaging the mechanics of the system.

4 Radno Lighted Chamber The sample chamber is illuminated with an imbedded light source in the wrist rest. The light is passed into the chamber via a glass light pipe integral to each of the individual chambers. When the chamber is docked into the wrist rest the light source aligns with the light pipe and light is passed to the chamber. The light source is activated via an on/off switch placed in the side of the wrist rest. When not in use for mounting, the user simply turns off the light source. The light source is powered by four AA batteries (included) that can be easily replaced when required. 5ml Working Volume Chamber Once mounted the sample is immersed into a 5ml working volume sample chamber that allows for filling, emptying and gassing of buffer solutions. A water-jacketed reservoir with a separate support stand is provided to permit convenient perfusion buffer exchanges. The elevation of the water jacketed reservoir provides a nominal pressure feed to the chambers simplifying fill cycles. Included is a water jacketed bath that can be used during the initial gross dissection that prepares the tissue segment for mounting. A vacuum flask is also provided with an appropriate manifold system to aid in empty cycles.

5 Precise Temperature Control The sample chamber is controlled to maintain accurate temperature of the sample and the buffer via the included M series thermostatic control unit. The control unit is available in both a four channel and single channel model. The M series thermostatic controllers precise electronics employ a adno communication loop from the microprocessor and the thermistor/ sensor. A variable electrical current is supplied to each individual chambers heating element in response to the thermistor probe signal. The probe is located directly in the sample chamber to avoid temperature over shoot greatly reducing the chance of overheating and tissue damage. Both M Series model thermostatic controllers incorporate a user friendly front panel alpha numeric LCD screen with a three button interface. The user steps through settings moving a blinking cursor using the up arrow or down arrow buttons. Ergonomically Designed for Ease of Use Both the single chamber base and the 4-chamber base assembly are ergonomically designed to allow the users wrist to be supported fully while in the process of manipulating the sample. This feature provides exceptional stability during the critical tissue mounting phase of the procedure. The units also allow for a low temperature and high temperature alarm setting. Once set, the controller continually monitors the individual vessel chambers temperature and displays the chambers value on the corresponding LCD screen. Temperature readings can be output via the rear panel RS-232 port for digital recording. Each vessel chamber uses easy to clean and replace buffer inlet, gas inlet and buffer outlet tubes. The tubes are fabricated of borosilicate glass to give the researcher a clear view of the fluid path during setup and experimentation.

6 o Sliding Wrist Rest The M4 four channel system has the added feature of a moving ergonomic wrist rest. This allows the user to move from chamber to chamber. Once the vessel is properly set the user simply moves the chamber unit back and moves on to the next chamber. The chambers with the loaded samples are then undisturbed during mounting of additional samples. This feature allows for easy manipulation of the chambers and helps steady the hands during use.

7 Radnoti M Series Myograph Chamber Buffer inlet tube Buffer outlet tube Gas inlet tube (sintered glass tipped) Transducer housing Micro vessel support bracket (fixed) Micro vessel support bracket (adjustable) Thermistor 5ml vessel chamber Y axis adjustment Z axis adjustment (minor) X axis adjustment micrometer

8 Radnoti M Series Myograph Chamber Micro vessel chamber light pipe Transducer safety lock Transducer amplifier connector Temperature controller connector

9 Myograph Material Specifications: Myograph chamber body: Myograph Base: Myograph Support Brackets: Support Bracket Linkage: Gas Inlet Tube: Buffer Inlet Tube: Buffer Outlet Tube: Polyester Material PET (Polyester) Opaque White Lowest Temperature -99 to -1 F Highest Temperature +201 to +300 F Operating Temperature Range -30 to +230 F Specifications met: (FDA) Compliant UL Rating: UL 94HB Thermostatic Temperature Controller Specifications: *PET Polyester Radno Chamber bath Temperature Control range: Ambient to 45C Regulation: +/- 1.0C Accuracy: +/- 1C Readout resolution: 0.1C Probe Sensor: Special LSI thermistor (YSI type 400 series) Display: 4-Line LCD. Temperature updated every second Power: 117v/60Hz or 220v/50Hz (as specified) Size: 22.5 x 7.5 x 17.5 cm (LxHxW) Weight: 1.25 kg Light Source: *PET Polyester *PET Polyester Stainless Steel Borosilicate Glass, Sintered Borosilicate Frit Borosilicate Glass Borosilicate Glass 4 AA Batteries Force Transducer Specifications: Isometric 0.0gm - 0.5gm / 0.0gm - 5.0gm force range (switch selectable) standard 0.0gm - 2.0gm / 0.0gm gm force range (switch selectable) optional Force Transducer Amplifier Specifications: Analog Electrical Output - 0 to 5.0 VDC depending upon the position of the range selector switch. *Output impedance is 2 kiloohms for direct connection to all recorders. Linearity is 0 to 100% overload (1 or 10 grams, depending on setting). Internal frequency response is selectable from 1000Hz to 10Hz

10 M 4 Myograph System Includes: 4 channel myograph base with sliding wrist rest and internal light source 1 Myograph chamber 4 Isometric force transducer and amplifier (transducer factory installed) 4 Myograph chamber calibration mount 1 M4 Series 4 channel Thermostatic Temperature Controller 1 Reservoir stand assembly 1 Radno Preparatory tissue bath 1 1 liter water jacketed reservoir 1 M4 Series tubbing kit 1 M4 Series cable set 1 M 1 Myograph System Includes: 1 channel myograph base with sliding wrist rest and internal light source 1 Myograph chamber 1 Isometric force transducer and amplifier (transducer factory installed) 1 Myograph chamber calibration mount 1 M1 Series 1 channel Thermostatic Temperature Controller 1 Reservoir stand assembly 1 1 liter water jacketed reservoir 1 M1 Series tubbing kit 1 M1 Series cable set 1 Preparatory tissue bath 1 Available Options: Olympus SZX10 Microscope Olympus SZ2-STU2 universal stand type 2 Myograph chamber covers Automated fluid control M Series Inverted microscope myograph chamber Accessories: Platinum field stimulating electrode set Wire myograph tissue strip mounting adapter set Optional Disecting Scope Data Acquisition: Speak to your local representative about optional hardware and software bundles, including data acquisition.

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page Measuring Devices Pressure range Connection Device Page Digital display mounting, für niedrige Drücke 0 2. mbar / 2. bar 4 mm tube MPV, MPA.02 portable, hand-operated 0 1 mbar / 10 bar 4 mm tube MHA.03

More information

Operations Manual EcoSense ph100a

Operations Manual EcoSense ph100a Operations Manual EcoSense ph100a Portable ph, mv and Temperature Instrument English CONTENTS GENERAL INTRODUCTION... 3 INITIAL INSPECTION... 3 THE INSTRUMENT... 3 BATTERY INSTALLATION... 3 Battery Disposal...

More information

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable VWR BALANCES A-Series Balances for High Precision with Advanced Features B2-Series Balances are Rugged, Affordable, and Reliable B2T-Series Balances Feature a 5 Color Touch Screen and Proximity Sensor

More information

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

1551 S. Harris Court,. Anaheim, CA Phone: Fax: 1551 S. Harris Court,. Anaheim, CA 92806 Phone: 714.978.1551... Fax: 714.978.0431 Model 4KE / 4KEH Series: Semi-Automatic, Motorized Y/Z Axes, Wedge-Wedge, Ball- Wedge Triple-Convertible Wire Bonders Last

More information

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012

ERNG-X. Description. Applications. ERNG-X Specifications DERNG2108X012 ERNG-X DERNG2108X012 Description The ERNG-X is a steady state no bleed engineered system for accurate and reliable control of Natural Gas. The ERNG-X includes a pressure regulator, preconditioning filters,

More information

Isotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific

Isotemp. Bath Circulators. Improve the productivity. of your lab with solutions. from Fisher Scientific Isotemp Bath Circulators Improve the productivity of your lab with solutions from Fisher Scientific I s o t e m p B a t h Isotemp Refrigerated and Heating Bath Circulators Three Controller Choices: Programmable,

More information

How to build a Conductivity Measurement System

How to build a Conductivity Measurement System How to build a Measurement System F B E C D A A Immersion system in open basin B Flow-through system C 1/2 pipe mounted system D 3/4 pipe mounted system E Side-entry system in vessel F Top-entry system

More information

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable VWR BALANCES A-Series Balances for High Precision with Advanced Features B2-Series Balances are Rugged, Affordable, and Reliable E-Series Balances for Entry Level Applications P-Series Balances for Portability

More information

ELARA flat photobioreactor

ELARA flat photobioreactor ELARA flat photobioreactor Scope of supply The system consists of 1.6 L (total volume) autoclavable flat photobioreactor, bench-top, pre-assembled unit, supplied with all necessary tubes, valves and instruments,

More information

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS

Inc. FLO-CAL Liquid Calibration System FLO-CAL SOFTWARE FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLEXIBLE DESIGN TO MEET YOUR LIQUID FLOW CALIBRATION REQUIREMENTS FLO-CAL A portable Liquid Flow Standard FLO-CAL INSTRUMENT Data acquisition and interface tool with flow meter frequency and analog signals.

More information

Refrigerated incubators with forced convection

Refrigerated incubators with forced convection KB series (E3.1) Incubators Refrigerated incubators with forced convection The most versatile incubator for microorganisms: The BINDER KB series controls a temperature range of -5 C to 100 C. With its

More information

AC-43 Accelerometer. User Manual

AC-43 Accelerometer. User Manual AC-43 Accelerometer Manual Page 1 AC-43 Accelerometer User Manual Company: Author: Checked: Approved: Distribution: GeoSIG Ltd Wiesenstrasse 39, 8952 Schlieren, Switzerland, Tel: +41 44 810 21 50, Fax:

More information

Spraybase Technical Specifications Sheet

Spraybase Technical Specifications Sheet The Spraybase electrospinning device offers a complete solution to users investigating electrospraying and electrospinning applications. Designed to be compact and easy to use, the Spraybase electrospinning

More information

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM-6650.02 1 Instruction Manual DM-6650.02 TABLE OF CONTENTS I.0 INTRODUCTION 3 1.1 General Description... 3 1.2 Specifications... 3 1.3

More information

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro

INSTRUCTION MANUAL. Digivac 760 Series. Models 100Led P / P / 29.9 100Led 760 / SixVac 801 / 760 / 2c 801 Micro INSTRUCTION MANUAL Digivac 760 Series Models 100Led 760 100P / 760 100P / 29.9" 100Led 760 / SixVac 801 / 760 / 2c 801 Micro Ranges 0 to 760 Torr 0 to 19.99 Torr 0 to 29.9 inches of mercury The Digivac

More information

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models

Richter Optica. Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models Richter Optica info@richter-optica.com Instructions for: S6-BL, S6-TS, S6-SPS, S6-ILST Models Trinocular port for c-mount adapter Zoom Knob Focusing Holder Clamp Diopter adjustable eyepieces Magnification

More information

KOBOLD PDA Series Digital Pressure Transmitter

KOBOLD PDA Series Digital Pressure Transmitter KOBOLD PDA Series Digital Pressure Transmitter PDA-153 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

Installation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING

Installation and Operation Manual. ETV Platinum Plus. Electronic Tempering Valve with Safeguard WARNING Installation and Operation Manual ETV Platinum Plus Electronic Tempering Valve with Safeguard WARNING This Heat-Timer control is strictly an operating control; it should never be used as a primary limit

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

1551 S. Harris Court,. Anaheim, CA Phone: Fax:

1551 S. Harris Court,. Anaheim, CA Phone: Fax: 1551 S. Harris Court,. Anaheim, CA 92806 Phone: 714.978.1551... Fax: 714.978.0431 Model 7300C Series: Single Head Die Bonders, Manual X-Y-Z Last revised: 09/19/18 - microscope Series Overview Application

More information

Flexible temperature transmitter and sensor

Flexible temperature transmitter and sensor / processing unit without display senso a mperature senso TT/TC series TT/TC ser Flexible temperature transmitter and sensor The of the TT/TC series detect temperature with a Pt100 4-wire probe. Available

More information

Instruction Sheet Board Style Low Water Cutoff

Instruction Sheet Board Style Low Water Cutoff Instruction Sheet Board Style Low Water Cutoff 102-305 SUPERSEDES: REVISION E DATED December 12, 2007 #5401173-REV F PLANT ID 001-3902 US Patents 6,904,800, 7,243,540, and 7,317,993 Other Patents Pending

More information

Calibration Equipment. for Testing Systems. walter+bai Testing Machines

Calibration Equipment. for Testing Systems. walter+bai Testing Machines Accessories for Materials Testing 309 for Testing Systems 310 Accessories for Materials Testing for Materials Testing Systems Equipment for the verification and calibration of materials testing machines

More information

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KMF 720 Constant climate chambers with expanded temperature / humidity range Model KMF 720 Constant climate chambers with expanded temperature / humidity range The BINDER KMF ensures absolutely constant test conditions throughout the testing area. A big advantage of this constant

More information

PT-DT70. Low-Head Tablet Dissolution Test Instrument

PT-DT70. Low-Head Tablet Dissolution Test Instrument PT-DT70 Low-Head Tablet Dissolution Test Instrument The PT-DT70 is the low head flip back tablet dissolution testing instrument from Pharma Test. It provides a space saving, low cost entry into dissolution

More information

Product data sheet accessories control and regulation Accessories AIRWIN

Product data sheet accessories control and regulation Accessories AIRWIN Product data sheet accessories control and regulation BO-CT1 Continuous controller Item no. 6100101 Control of humidification performance BO-CT1 Option board 2 binary inputs Item no. 002212 Setpoint switching,

More information

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable Features DMX512 Controllable and RDM Configurable Designed for driving LED strips through 6 high power 12 and 24 Volts output units available Easy addressing interface (physical switches and RDM) Isolated

More information

ONYX 32 MULTIFUNCTIONAL POSITIONING AND SOLDERING SYSTEM

ONYX 32 MULTIFUNCTIONAL POSITIONING AND SOLDERING SYSTEM ONYX MULTIFUNCTIONAL POSITIONING AND SOLDERING SYSTEM MACHINES.0 APPLICATION: SMT ZEVAC-LINE: ONYX The complete ONYX product line documentation is composed of the following data sheets: MACHINES.0 ACCESSORIES.0,.0

More information

MPI TS150-THZ 150 mm Manual Probe System

MPI TS150-THZ 150 mm Manual Probe System MPI TS150-THZ 150 mm Manual Probe System Industry s first explicitly designed probe system for accurate measurements at mm-wave and sub-mm wave (THz) frequency range FEATURES / BENEFITS Variety of Applications

More information

Installation and operation manual ReciFlow Gas

Installation and operation manual ReciFlow Gas Installation and operation manual ReciFlow Gas 1 1. Measurement principle... 3 2. Installation... 5 3. Operation... 7 4. Electrical interfaces... 11 5. Communication protocol... 14 6. Software update and

More information

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4

Industrial. Laboratory and Field. Accessories. Product Selection Guide. Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Product Selection Guide Industrial Analyzers 1 Controllers 2 Transmitters 3 Monitors 4 Laboratory and Field Benchtop Meters 5 Field Meters 5 Benchtop Controllers 7 Pocket Meters & Testers 9 Accessories

More information

QUICKSTART GUIDE. Infrared Gas Analyzer. Teledyne Analytical Instruments

QUICKSTART GUIDE. Infrared Gas Analyzer. Teledyne Analytical Instruments QUICKSTART GUIDE MODEL 7500 Teledyne Analytical Instruments Quickstart Guide Teledyne Analytical Instruments Model 7500 Quickstart Guide GETTING STARTED This Quickstart Guide is designed to get you set

More information

WE TAKE RESEARCH TO HEART SCP + SCPC THE CENTRIFUGAL PUMP SYSTEM

WE TAKE RESEARCH TO HEART SCP + SCPC THE CENTRIFUGAL PUMP SYSTEM WE TAKE RESEARCH TO HEART SCP + SCPC THE CENTRIFUGAL PUMP SYSTEM SCP THE INTEGRATED CENTRIFUGAL PUMP SYSTEM THE CONCEPT The Stöckert SCP contributes to meeting the globally increasing demand for centrifugal

More information

analysette 3 particle size analysis quality control sieving for your lab Vibratory Sieve Shaker Microprocessor controlled

analysette 3 particle size analysis quality control sieving for your lab Vibratory Sieve Shaker Microprocessor controlled analysette 3 Vibratory Sieve Shaker Microprocessor controlled with optical display of all functions Digital adjustment and regulation of amplitude: AMPCONTROL Up to 9 sieve programmes can be saved and

More information

HI 9828 Multiparameter Water Quality Meter...

HI 9828 Multiparameter Water Quality Meter... HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe

More information

KOBOLD TDA Series Digital Temperature Transmitter

KOBOLD TDA Series Digital Temperature Transmitter KOBOLD TDA Series Digital Temperature Transmitter TDA-15 Series User Instructions KOBOLD Instruments Inc. 1801 Parkway View Drive Pittsburgh, PA 15205 Phone (412) 788-2830 Fax (412)-788-4890 www.koboldusa.com

More information

Portable Temperature Calibrator QUARTZ Dry Block Calibrator -50 C C

Portable Temperature Calibrator QUARTZ Dry Block Calibrator -50 C C Portable Temperature Calibrator QUARTZ Dry Block Calibrator -50 C...+150 C QUARTZ-35 Dry Block Temperature Calibrator QUARTZ-35 Temperature range: -30 C up to +150 C (at 20 C ambient temperature) Type

More information

Technical Specifications

Technical Specifications Technical Specifications Version 2.48/2.49 2007-2008 Rev: January 2007 SQA-V Gold Technical Specifications The SQA-V is a high performance analytical medical device that combines state-ofthe-art technology

More information

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

SUPER LEDF10HP DATASHEET

SUPER LEDF10HP DATASHEET DATASHEET LED Fresnel Spotlight 330W - CRI>95 White light, either Tungsten or Daylight balanced OVERVIEW The Super LED F10HP is a high efficiency Fresnel lens spotlight using the innovative High Power

More information

MPI TS150-AIT 150 mm Manual Probe System

MPI TS150-AIT 150 mm Manual Probe System MPI TS150-AIT 150 mm Manual Probe System Industry s first explicitly designed 150 mm probe system providing accurate tests for mm-wave, THz, and automated impedance tuner applications FEATURES / BENEFITS

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

Model KBW 720 Growth chambers with light

Model KBW 720 Growth chambers with light Model KBW 720 Growth chambers with light The BINDER climate chamber with illumination of the KBW series achieves homogeneous light distribution with its natural illumination. That allows this growth chamber

More information

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax: OPERATION MANUAL /ORP 300 (Cat. No. 0580212) MICROCOMPUTER BASED /ORP/ Temperature CONTROLLER 625 East Bunker CT, Vernon Hills, IL 60061-1844 Phone: 800-32-4340, Fax: 847-247-2929 E-mail: info@coleparmer.com,

More information

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

Led Illuminator and Light Stimulator. Model # LSD-1. Ver Led Illuminator and Light Stimulator Model # LSD-1 Ver. 2.0.0 5.16 ALA Scientific Instruments Inc. 60 Marine Street, Farmingdale, NY 11735 Voice: +1 631.393.6401 fax: +1 631.393.6407 www.alascience.com

More information

Model VD 23 Vacuum drying chambers for non-flammable solvents

Model VD 23 Vacuum drying chambers for non-flammable solvents Model VD 23 Vacuum drying chambers for non-flammable solvents A BINDER vacuum drying oven VD series gently dries materials with homogeneous temperature distribution. The patented expansion shelf technology

More information

Temperature sensors TTM series. Miniature transmitters

Temperature sensors TTM series. Miniature transmitters Temperature senso a mperature senso Temperature sensors TTM series TTM serie Miniature transmitters The TTM miniature sensors detect temperature with a 4-wire Pt1000 probe. Available are compact devices

More information

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service Series Flowmeter for compressed air and gases in Industrial Applications The flowmeter of the series, based on the measurement principle of thermal mass flow, is ideally suited for the measurement of flow

More information

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F

Resolution 1 F (1 C) single point; degrees C or Calibration single or dual point Calibration F RMS Rainwater Harvesting Series 100 Controller Specifications Measurement Performance Contacting Conductivity ph Range 0-10,000 µs/cm Range -2 to 16 ph units Resolution 1 µs/cm Resolution 0.01 ph units

More information

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems

Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems Well Probe Mechanically Activated Device for Dry Run Protection in Applications with LORENTZ Solar Pump Systems The switch can be used to detect the water level within a well. When the water level in the

More information

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial

More information

USB-500/600 Series Low-Cost Data Loggers and Accessories

USB-500/600 Series Low-Cost Data Loggers and Accessories Low-Cost Data Loggers and Accessories Features Stand-alone, remote data loggers and portable logger assistant Measure temperature, humidity, voltage, current, or event/state change 1 or 2 channels Low

More information

SUPER LEDF6 DATASHEET

SUPER LEDF6 DATASHEET SUPER DATASHEET LED Fresnel Spotlight 120W - CRI>96 White light, either Tungsten or Daylight balanced OVERVIEW The Super LED F6 is a high efficiency Fresnel lens spotlight using the innovative High Power

More information

Sartorius Research. R 160 P Electronic Semi-Microbalance

Sartorius Research. R 160 P Electronic Semi-Microbalance Sartorius Research. R 160 P Electronic Semi-Microbalance Installation and Operating Instructions 1 Power receptacle, fuse, 8 Level indicator voltage selector 9 ON/OFF key 2 Menu access switch 10 Print

More information

Educational Microfluidic Starter Kit

Educational Microfluidic Starter Kit Educational Microfluidic Starter Kit Product datasheet Page Description 4 Benefits 5 System Specifications 5 Typical System setup 6 Parts List 7 IP License 19 MAR-000189_v.A.11 Page 1 of 20 Low Pressure

More information

InBin-P Pressure switches from 5 Pa Pa

InBin-P Pressure switches from 5 Pa Pa InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact

More information

Dry Block Heaters. Quality Selection Value

Dry Block Heaters. Quality Selection Value Dry Block Heaters Quality Selection Value Advanced Dry Block Heaters Exceptional temperature uniformity and stability Optional external temperature probe Heats from ambient to 120 C Holds interchangeable

More information

ph/orp Meter SD Card real-time Datalogger

ph/orp Meter SD Card real-time Datalogger User's Guide ph/orp Meter SD Card real-time Datalogger Model SDL100 Introduction Congratulations on your purchase of the Extech SDL100 ph/orp Meter, an SD Logger Series meter. This meter displays and stores

More information

Installation Instructions

Installation Instructions Installation Instructions USM 4 Sensor Input Vnet Module Racepak PN: 230-VM-USM Racepak Data Systems 30402 Esperanza Rancho Santa Margarita, CA 92688 949-709-5555 www.racepak.com Table of Contents PRODUCT

More information

TOXALERT MODEL AIR 2000

TOXALERT MODEL AIR 2000 TOXALERT MODEL AIR 2000 NOTE: Toxalert s Model GVU-CO 2 Sensor is the same as the Air2000R. Microprocessor-based, Infrared Environmental CO 2 Sensor OPERATOR S MANUAL TOXALERT TM INTERNATIONAL INC. P.O.

More information

Conductivity Transmitters

Conductivity Transmitters Conductivity Transmitters CDTX-90 Series Starts at $ 576 Electronics Only Display in µs, ms, kω, MΩ, ppm (TDS) Simulate Function Programmable Temperature Compensation Relay Options Dual Output Option Allows

More information

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features Features Ranges from -45 C to 650 C Measures reference probe, RTDs, T/Cs, ma, mv and ohms Rapid heating, cooling and settling Ramp, step and preset functions Reads set temperature and device output simultaneously

More information

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2-16; P=87 PSI Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-20 PELTIER TEMPERATURE CONTROL SYSTEM

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-20 PELTIER TEMPERATURE CONTROL SYSTEM OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE PTC-20 PELTIER TEMPERATURE CONTROL SYSTEM VERSION 2.11 npi 2002 npi electronic GmbH, Hauptstrasse 96, D-71732 Tamm, Germany Phone +49 (0)7141-601534;

More information

Talboys Standard Analog Dry Block Heaters

Talboys Standard Analog Dry Block Heaters Talboys Standard Analog Dry Block Heaters -Holds interchangeable modular blocks. -Analog controls. -High wattage, constant-temperature Dry Block Heaters are economical, versatile and compact. -These multi-purpose

More information

Linkam Scientific Instruments

Linkam Scientific Instruments THMS600PS Pressure System By pressurizing the sample chamber up to 14bar the THMS600-PS pressure stage can be used to investigate the effects of pressure on the sample during heating and cooling experiments.

More information

Reaction Blocks for Circular-top Hot Plate/Stirrers

Reaction Blocks for Circular-top Hot Plate/Stirrers P 2010 C O N TA R I C I I N S G N Reaction Blocks for Circular-top Hot Plate/Stirrers New sizes Easy to use Complete systems Radley s and ACE brand Economical and efficient www.aceglass.com sales@aceglass.com

More information

Rotary Microtomes. Tissue Processors. Embedding Centers. Microtomes. Cryostats. Water Bath & Slide Warmer. Staining Systems.

Rotary Microtomes. Tissue Processors. Embedding Centers. Microtomes. Cryostats. Water Bath & Slide Warmer. Staining Systems. Rotary Microtomes All SLEE microtomes are produced at the company s seat in Mainz, Germany. The highly precise, modularly built rotary microtomes range from a manual unit, type CUT 4062, via the semi-automatic

More information

Mini Probe. user manual. DM Models

Mini Probe. user manual. DM Models Mini Probe user manual DM Models 1.0: Index Section Title Page 1.0 Index...............................2 2.0 Safety Summary......................3 3.0 Introduction..........................4 4.0 Components

More information

AIR or STACK MONITOR GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE

AIR or STACK MONITOR GAS, GROSS BETA-GAMMA PARTICULATE, & IODINE FEATURES: AIR or STACK MONITOR THREE CHANNEL SIMULTANEOUS MEASUREMENT DETECTOR VERIFICATION CAPABILITY USING GAS & SOLID SOURCES EASY DETECTOR SYSTEM CALIBRATION WITH BUILT-IN CALIBRATION INTERFACE INTERNAL

More information

Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws.

Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws. APS-M1 Accessories Sensor System Analog Position Sensor Analog Position Sensor System Mechanical, analog system comprising sensor and processor for accurately recording the position of gripper jaws. Function

More information

D-510 PISeca Single-Electrode Capacitive Sensor Probe

D-510 PISeca Single-Electrode Capacitive Sensor Probe Technical Note BSc, BRo, D-510 PISeca Single-Electrode Capacitive Sensor Probe Fig. 1: D-510 Single-Electrode Capacitive Sensor probe with E-852.10 signal conditioner electronics The D-510 Single-Electrode

More information

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi V161102 Liquid Level Sensor Sensor for measuring the level of liquid in a well or tank USE / PURPOSE The range of liquid level sensors use pressure to measure the liquid level in a well or tank. The sensors

More information

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230

NT PRESSURE TRANSDUCER MODELS 4100, 4210, 4130, 4230 P/N 0-027289 (Rev. A 04/4) NT PRESSURE TRANSDUCER MODELS 400, 420, 430, 4230 User Guide Table of Contents Safety Alert Symbol... 2 Introduction... 3 Installation... 3 Mechanical Installation... 3 Electrical

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

Fiber Optic Distributed Temperature Sensors (B-DTS)

Fiber Optic Distributed Temperature Sensors (B-DTS) Fiber Optic Distributed Temperature Sensors (B-DTS) Low-cost Brillouin BOTDA scattering version For more information about our strain and temperature sensor system and related products, please visit www.ozoptics.com

More information

Operations Manual EcoSense ph100

Operations Manual EcoSense ph100 Operations Manual EcoSense ph100 Portable ph, mv and Temperature Instrument English Français Español Deutsch Italiano WARRANTY The EcoSense ph100 Instrument is warranted for one year from date of purchase

More information

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller Operation Manual TX10 1/8 DIN Microcomputer Based /ORP Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING THE Sensorex

More information

User's Guide. Video Borescope. Models BR200 and BR250

User's Guide. Video Borescope. Models BR200 and BR250 User's Guide Video Borescope Models BR200 and BR250 Introduction Congratulations on your purchase of this Extech BR200 (17mm camera head) or BR250 (9mm camera head) Video Borescope. This instrument was

More information

Model KB 240 Cooling incubators with compressor technology

Model KB 240 Cooling incubators with compressor technology Model KB 240 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes

More information

Model KT 53 Cooling incubators with thermoelectric cooling

Model KT 53 Cooling incubators with thermoelectric cooling Model KT 53 Cooling incubators with thermoelectric cooling The KT series combines outstanding performance with impressive energy efficiency and environmental friendliness. The cooled incubators of the

More information

Dräger Polytron 8200 Stationary gas detector (CatEx)

Dräger Polytron 8200 Stationary gas detector (CatEx) Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result

More information

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,

More information

Wolf Laboratories Limited

Wolf Laboratories Limited Wolf Laboratories Limited www.wolflabs.co.uk Tel: 01759 301142 Fax:01759 301143 sales@wolflabs.co.uk Use the above details to contact us if this literature doesn't answer all your questions. Pricing on

More information

Mitos P-Pump. product datasheet

Mitos P-Pump. product datasheet product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump

More information

Macro View All in One Scope Description. 2. Features. 3. Package Contents

Macro View All in One Scope Description. 2. Features. 3. Package Contents Macro View All in One Scope 26700-104-00 1. Description Portable system ideal for inline use This self-contained video inspection system is a compact unit, that simplifies quality checks at any stage of

More information

GESOTEC Advanced Industrial Temperature Monitoring & Control

GESOTEC Advanced Industrial Temperature Monitoring & Control PyroViper2 -MWIR state-of-the-art Imaging Pyrometers PyroViper TM furnace probe camera models PV2-MWIR not only provide state-of-the-art infrared imaging for industrial high temperature process scenarios

More information

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at

User s Manual. Models Digital Force Gauge. Additional User Manual Translations available at User s Manual Models 475055 Digital Force Gauge Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of Extech s Model 475055 Digital Force Gauge

More information

Super LED F6 VW Vari-White

Super LED F6 VW Vari-White Super LED F6 VW Vari-White LED Fresnel SPOTLIGHT 120W Vari-White from 2.800 to 6.600 K - Enhanced CRI > 94 White light, with Adjustable Correlated Colour Temperature OVERVIEW The De Sisti Vari-White LED

More information

Reaction Blocks for Circular-top Hot Plate/Stirrers. New sizes Easy to use Complete systems Economical and efficient

Reaction Blocks for Circular-top Hot Plate/Stirrers. New sizes Easy to use Complete systems Economical and efficient Reaction Blocks for Circular-top Hot Plate/Stirrers New sizes Easy to use Complete systems Economical and efficient ACE DynaBloc anodized aluminum blocks are ideal for heating and mixing solutions in a

More information

Data logger systems from ROTRONIC

Data logger systems from ROTRONIC Data logger systems from ROTRONIC RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network RS-485 Logger, power supply via RS-485 network Logger with power supply RS-485

More information

IKA Crushing 76 Dispersers (batch operation)

IKA Crushing 76 Dispersers (batch operation) 76 Dispersers (batch operation) Dispersers (batch operation) 77 T 18 basic ULTRA-TURRAX Competitively priced dispersing instrument for volumes of 1 to 1.500 ml (H2O). A wide speed range allows you to work

More information

( F L O W I Z F A M I L Y )

( F L O W I Z F A M I L Y ) THE MOST ACCURATE BATTERY POWERED SYSTEM ML 145 ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w

More information

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TC-20 TEMPERATURE CONTROL SYSTEM

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TC-20 TEMPERATURE CONTROL SYSTEM OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TC-20 TEMPERATURE CONTROL SYSTEM VERSION 3.8 npi 2016 npi electronic GmbH, Bauhofring 16, D-71732 Tamm, Germany Phone +49 (0)7141-9730230; Fax: +49

More information

Hand-Held Thermometer Model CTH 6200

Hand-Held Thermometer Model CTH 6200 Testing and Calibration Technology Hand-Held Thermometer Model CTH 6200 WIKA Data Sheet CT 51.01 Applications Service industry Measurement and and control laboratories Industry (laboratory, workshop and

More information

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory 6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory Overvoltage Category II Pollution Degree 2 Equipment Class III Safety information Introduction Before using this accessory, you must read

More information

More Precision. eddyncdt // Eddy current sensors for displacement and position

More Precision. eddyncdt // Eddy current sensors for displacement and position More Precision eddyncdt // Eddy current sensors for displacement and position 18 High precision eddy current displacement measurement eddyncdt 00 - Micrometer accuracy - Ideal for fast measurements: Bandwidth

More information

DST600. Digi-Stem Digital RTD Reference Thermometer for Retorts & Temperature Critical Applications. Exclusive Continuous Self-Checking Technology

DST600. Digi-Stem Digital RTD Reference Thermometer for Retorts & Temperature Critical Applications. Exclusive Continuous Self-Checking Technology Actual Size Exclusive Continuous Self-Checking Technology Trustworthy Alternative to Mercury-in-Glass Designed in compliance with the FDA Final Rule Change for 21 CFR Part 113 Digi-Stem Digital RTD Reference

More information

CAEL-DP Series Dew Point Transmitter for Industrial Control

CAEL-DP Series Dew Point Transmitter for Industrial Control CAEL-DP Series Dew Point Transmitter for Industrial Control SERIAL's latest CAEL series Dew Point transmitter meets the harsh environmental requirements for Dew Point measurement. Via temperature and relative

More information

1523/1524 Reference Thermometers

1523/1524 Reference Thermometers 1523/1524 Reference Thermometers Measure, graph and record three sensor types with one tool High accuracy PRTs: up to ± 0.011 C Thermocouples: up to ± 0.24 C Precision thermistors: ± 0.002 C Two models

More information