Inverter. E84AVSCxxxxx... Inverter Drives 8400 StateLine C Quick start guide EN. Ä.H)lä

Size: px
Start display at page:

Download "Inverter. E84AVSCxxxxx... Inverter Drives 8400 StateLine C Quick start guide EN. Ä.H)lä"

Transcription

1 Inverter 8400 E84AVSCxxxxx... Inverter Drives 8400 StateLine C Quick start guide EN Ä.H)lä L

2 Contents 1 General safety and application notes _ 3 2 Drive behaviour by default _ 4 3 Quick commissioning for test / demonstration purposes _ 5 4 Adapting the drive behaviour by parameterisation General notes on parameters Commissioning using PC and»engineer«_ 7 11 About this documentation This documentation serves as a quick start guide for parameterising the "conveyor drive" application. It applies to the 8400 StateLine C controller with the following nameplate data: Product series Type designation from software version 8400 StateLine C E84AVSCxxxxx Definition of the notes used The following signal words and symbols are used in this documentation to indicate dangers and important information: Icon Signal word Meaning Danger! Danger of personal injury through a general source of danger Reference to an imminent danger that may result in death or serious personal injury if the corresponding measures are not taken. Stop! Danger of property damage Reference to a possible danger that may result in property damage if the corresponding measures are not taken. Note! Important note to ensure trouble-free operation 2 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

3 1 General safety and application notes 1 General safety and application notes For Lenze controllers (according to Low-Voltage Directive 2006/95/EC) For your personal safety Disregarding the following safety measures can lead to severe injury to persons and damage to material assets: Only use the product as directed. Never commission the product in the event of visible damage. Never commission the product before assembly has been completed. Do not carry out any technical changes on the product. Only use the accessories approved for the product. Only use original spare parts from Lenze. Observe all regulations for the prevention of accidents, directives and laws applicable on site. Transport, installation, commissioning and maintenance work must only be carried out by qualified personnel. Observe IEC 364 and CENELEC HD 384 or DIN VDE 0100 and IEC report 664 or DIN VDE 0110 and all national regulations for the prevention of accidents. According to this basic safety information, qualified, skilled personnel are persons who are familiar with the assembly, installation, commissioning, and operation of the product and who have the qualifications necessary for their occupation. Observe all specifications in the hardware manual and in this documentation. This is the condition for safe and trouble-free operation and the achievement of the specified product features. The procedural notes and circuit details described in the hardware manual and in this documentation are only proposals. It's up to the user to check whether they can be transferred to the particular applications. Lenze Drives GmbH does not accept any liability for the suitability of the procedures and circuit proposals described. Depending on their degree of protection, some parts of the Lenze controllers (frequency inverters, servo inverters, DC speed controllers) and their accessory components can be live, moving and rotating during operation. Surfaces can be hot. Non-authorised removal of the required cover, inappropriate use, incorrect installation or operation, creates the risk of severe injury to persons or damage to material assets. For more information, please see the documentation. High amounts of energy are produced in the controller. Therefore it is required to wear personal protective equipment (body protection, headgear, eye protection, ear protection, hand guard). Danger! The safety and application notes given in the hardware manual must be observed! The product-specific safety and application notes given in these instructions must be observed! For Lenze motors (according to Low-Voltage Directive 2006/95/EC) General Lowvoltage machines have hazardous live and rotating parts and possibly also hot surfaces. Synchronous machines induce voltages at open terminals during operation. All operations concerning transport, connections, commissioning and maintenance must be carried out by qualified, skilled personnel (EN (VDE ) and IEC must be observed). Inappropriate use creates the risk of severe injury to persons and damage to material assets. Lowvoltage machines may only be operated under the conditions that are indicated in the section "Application as directed" of the hardware manual. The conditions at the place of installation must comply with the data given on the nameplate and in the documentation. Residual hazards Protection of persons Before working on the controller, check if no voltage is applied to the power terminals because - depending on the device - the power terminals U, V, W, +UG, - UG, Rb1 and Rb2 remain live for at least minutes after disconnecting the mains. the power terminals L1, L2, L3; U, V, W, +UG, - UG, Rb1 and Rb2 remain live when the motor is stopped. Device protection Connect/disconnect all pluggable terminals only in deenergised condition! Detach the controller from the installation, e.g. from the rear panel of the control cabinet, only in deenergised condition! Motor protection With certain settings of the controller, the connected motor can be overheated. E.g. longer operation of the DC injection brake. Longer operation of self-ventilated motors at low speed. Protection of the machine/plant Drives can reach dangerous over-speeds (e. g. setting of high output frequencies in connection with motors and machines not suitable for this purpose)! The drive controllers do not provide protection against such operating conditions. For this purpose, use additional components. Switch contactors in the motor cable only if the controller is inhibited. When switching contactors in the motor cable while the controller is enabled, you can activate monitoring functions of the controller. If no monitoring function is activated, switching is permissible. Parameter set transfer During the parameter set transfer, control terminals of the controllers can adopt undefined states! Therefore it is required to disable the terminal X4 (digital input signals) before the transfer starts. This ensures that the controller is inhibited and all control terminals have the firmly defined "LOW" status. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 3

4 2 Drive behaviour by default 2 Drive behaviour by default Preset motor control "V/f characteristic control (VFCplus)" The 8400 StateLine controller supports various processes for motor control. By default, the V/f characteristic control (VFCplus) with linear characteristic for asynchronous motors is preset. The presettings of the parameters ensure that the controller is immediately ready for operation and the motor works adequately without further parameterisation if a controller and a 50 Hz asynchronous machine with matching performances are assigned to each other. Preset technology application "speed actuating drive" The 8400 StateLine controller features several integrated "technology applications" for solving various tasks. By default, the technology application "speed actuating drive" is preset. The technology application "speed actuating drive" serves to solve speed-controlled drive tasks, e.g. conveyor drives (interconnected), extruders, test benches, vibrators, travelling drives, presses, machining systems, metering units. Pre-assignment of the analog and digital terminals Different control modes are available for each technology application. By selecting the control mode you set the way the technology application should be controlled, e.g. via terminals or via a fieldbus. By default, the "Terminals 0" control mode is set for the "speed actuating drive" technology application with the analog and digital terminals assigned as follows: Control mode "Terminals 0" Analog terminals - X3 A1U Selected speed setpoint (10 V 100 % reference speed 1500 rpm *) O1U Actual speed output (10 V 100 % reference speed 1500 rpm *) Digital terminals - X4 RFR Controller enable RFR LOW (or open) HIGH HIGH LOW DI1 DI2 DI3 DI4 DO1 Function Controller inhibit Controller enable Reset error message Overriding fixed setpoints Alternatively to the speed selection via the analog input 1, "fixed setpoints" (JOG values) can also be activated via the digital terminals. DI1 DI2 Function LOW LOW Speed selection via analog input 1 (terminal A1U) HIGH LOW Fixed setpoint 1: 40 % reference speed 600 rpm * LOW HIGH Fixed setpoint 2: 60 % reference speed 900 rpm * HIGH HIGH Fixed setpoint 3: 80 % reference speed 1200 rpm * Manual DC-injection braking Manual DC-injection braking allows the drive to be quickly braked to a standstill without the need to use an external brake resistor. Change of direction of rotation Status "Drive is ready" * applies to 4-pole asynchronous motors 4 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

5 3 Quick commissioning for test / demonstration purposes 3 Quick commissioning for test / demonstration purposes Target: For test and demonstration purposes, the load-free motor shall be rotated in best time with an amount of wiring as little as possible. System constellation 8400 StateLine U V W X3 O1U GA A1I A1U AR GIO DO1 DI4 DI3 X4 DI2 DI1 RFR 24I 24E M 3~ V P1 1k... 10k S1 i Setpoint speed Controller enable Switching on the controller and specifying the speed setpoint 1. Before switch-on: Make sure that the controller is inhibited (switch S1 open). 2. Switch on voltage supply of the controller. If the green "DRV-RDY" LED is blinking and the red "DRV-ERR" LED is off, the controller is ready to be enabled. 3. Enable controller: Close switch S1. Now the drive follows the speed setpoint specified via the setpoint potentiometer P1. Speed characteristic (example) U A1U RFR [V] 10 Controller enable via S1 t 5 0 n [rpm] 1500 Setpoint speed via P1 t s Setpoint speed (internal) 2s t Notes: The scaling 10V 1500 rpm applies to 4-pole asynchronous motors. In order to prevent jumps, the speed setpoint is led via a ramp generator. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 5

6 4 Adapting the drive behaviour by parameterisation 4.1 General notes on parameters 4 Adapting the drive behaviour by parameterisation Being a component of a machine which includes a speed-variable drive system, the controller needs to be adjusted to its drive task by changing parameters. Access to the parameters of the controller is possible with the keypad, with the Engineering tools»easy Starter«and»Engineer«, with a master control via fieldbus communication (e.g. via CAN). Danger! In general, changing a parameter causes an immediate response in the controller! An enabled controller can cause an unwanted behaviour at the motor shaft! For instance, setpoint sources can change over abruptly (e.g. when the signal source is configured for the main setpoint). Certain device commands or settings which may cause critical states of drive behaviour constitute exceptions. Such parameter changes are only possible if the controller is inhibited. Otherwise, a corresponding error message will be issued. 4.1 General notes on parameters All parameters for controller parameterising or monitoring are saved as "codes". The codes are numbered and indicated by the prefix "C" before the code, e.g. "C00011". Moreover, each code has a name and specific attributes, as for example access type (reading, writing), data type, limit values and default setting ("Lenze setting"). For the sake of clarity, some codes contain "subcodes" for saving parameters. This manual uses a slash "/" as a separator between code and subcode, e.g. C00039/1". According to their functionality, the parameters are divided into three groups: Setting parameters: For specifying setpoints and for setting device / monitoring functions. Configuration parameters: For configuring signal connections and terminal assignments. Diagnostic/display parameters: For displaying device-internal process factors, current actual values and status messages. 6 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

7 4 Adapting the drive behaviour by parameterisation 4.2 Commissioning using PC and»engineer«4.2 Commissioning using PC and»engineer«we recommend using the»engineer«to parameterise the "conveyor drive" application described in this documentation. The»Engineer«is a Lenze engineering software for parameter setting across all devices, configuring and diagnosing individual components (as for instance controllers, industrial PCs, motors, I/O systems) and machine control systems. Preconditions for commissioning with the»engineer«for commissioning, you need a PC that satisfies the following requirements: IBM-compatible PC with Intel processor with at least 1.4 GHz or similar Microsoft Windows XP Professional (32 bits) as of SP3 / Windows Server 2003 / Windows Server 2008 / Windows 7 (32 and 64 bits) / Windows 8 at least 1 GB RAM and 2 GB free hard disk space at least 1024 x 768 pixels of screen resolution with a 256-colour palette the»engineer«pc software The»Engineer StateLevel«is provided free of charge in the internet: Download Software downloads a communication link to the controller, e.g. via a USB diagnostic adapter (E94AZCUS). Going online and searching for devices System constellation 8400 StateLine DIAG GIO DO1 DI4 DI3 X4 DI2 DI1 RFR 24I 24E X6 S1 DC 24 V E94AZCUS 1. Before switch-on: Make sure that the controller is inhibited (switch S1 open). 2. Switch on voltage supply of the controller. For parameterising and diagnosing the controller without motor operation a 24-V supply by a safely separated power supply unit (SELV/PELV) is sufficient. 3. Establish a communication link between the controller and the Engineering PC, e.g. via USB diagnostic adapter (E94AZCUS): connect the USB diagnostic adapter to the X6 diagnostic interface. establish a connection between the USB diagnostic adapter and the PC via a free USB port. 4. Start the»engineer«on the Engineering PC, e.g. via the Windows start menu: Start All programs Lenze Engineering L-force Engineer... After the program has been started, first, no project is loaded and the start-up wizard is displayed. The following steps describe the standard procedure for creating a project based on the option New project (upload data from system). Information on the other options of the start-up wizard and the general use of the»engineer«can be found in the online help for the program which you can call with [F1]. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 7

8 4 Adapting the drive behaviour by parameterisation 4.2 Commissioning using PC and»engineer«step 1 - What would you like to do? 1. Negate the option "Do you want to open an existing Engineer project?". 2. Select the option New project (upload data from system). 3. Tick Quick start... to skip the entry of the project properties. 4. Click Next. 8 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

9 4 Adapting the drive behaviour by parameterisation 4.2 Commissioning using PC and»engineer«step 2 - Read online data 1. If a communication link other than the USB diagnostic adapter is used between the PC and the controller, select it in the Bus connection list field. 2. Click Start Search... Now, the»engineer«searches for connected devices via the selected bus connection and lists these in the Identified devices list field. If several devices are listed, select the device to be entered (8400 StateLine). 3. Click Complete. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 9

10 4 Adapting the drive behaviour by parameterisation 4.2 Commissioning using PC and»engineer«step 3 - Upload from device Click Next to upload the parameters from the controller. The execution progress is displayed. After successful execution the Upload from device dialog box is closed automatically. the identified components are displayed in the project view an online connection to the 8400 StateLine controller continues to exist (recognisable by the symbol highlighted in yellow in the project view). The parameterisation dialogs now display the current parameter settings of the controller. Stop! If you change parameters in the»engineer«while the device is online, the changes are directly transmitted to the device! 10 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

11 This chapter describes the basic settings for quickly implementing a conveyor drive. System constellation 8400 StateLine DIAG U V W X3 O1U GA A1I A1U AR GIO DO1 DI4 DI3 X4 DI2 DI1 RFR 24I 24E X6 E94AZCUS M 3~ V 2mA V P1 1k... 10k S1 i DC 24 V ( V) Notes on how to wire the control terminals For a control via terminals, four control modes with different pre-assignments of the digital inputs DI1... DI4 are available: Digital input Pre-assignment in the control mode Terminals_0 Terminals_2 Terminals_11 Terminals_16 DI1 Fixed setpoint 1/3 Fixed setpoint 1/3 Change of direction of rotation DI2 Fixed setpoint 2/3 Fixed setpoint 2/3 Manual DC-injection braking DI3 DI4 Manual DC-injection braking Change of direction of rotation Quick stop Change of direction of rotation Motor potentiometer: Increase speed Motor potentiometer: Reduce speed Fixed setpoint 1/3 Fixed setpoint 2/3 CW rotation quick stop CCW rotation quick stop Select a control mode suitable for your application and wire the digital inputs DI1... DI4 accordingly. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 11

12 Setting of the basic parameters using the commissioning wizard 8400 The commissioning wizard 8400 serves to carry out a guided commissioning of the controller based on the Lenze setting of the parameters. 1. In the Project view, select the 8400 StateLine controller. 2. Click the symbol in the toolbar to start the Commissioning wizard Step 1 Start 1. Click the Set Lenze settings button. (Only after setting the parameters to the Lenze setting, the Next button can be activated.) 2. Click Next. Now the commissioning wizard guides you step by step through the setting of the important parameters for a quick commissioning. Information and notes on each commissioning step as well as useful settings and recommendations for the "conveyor drive" application can be found in the following sections. 12 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

13 Step 2 Motor selection 1. Select connected motor. 2. If you use a Lenze motor: Click the Select a motor button. The Motor selection dialog box is displayed: Select the used Lenze motor and confirm the motor selection with OK. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 13

14 Thereupon, the motor and plant parameters to be transmitted to the controller are displayed in the Use motor's default values dialog box. Leave all checkboxes checked and confirm the acceptance of the default values with OK. The dialog box is closed and you are in the commissioning wizard again. 3. Click Next. Step 3 Mains voltage 1. Set the mains voltage which is used to operate the device. The set mains voltage influences the brake chopper threshold, the monitoring of the device utilisation (Ixt) and the switch-off threshold in case of undervoltage in the DC bus. 2. Click Next. 14 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

15 Step 4 Control mode 1. Set the control mode which has been selected for wiring the control terminals. 2. Click Next. Step 5 Motor control We recommend the energy-saving "V/f eco" V/f operating mode for the material handling technology. With this operating mode, the motor voltage of the inverter is detected by means of a linear characteristic as a function of the field frequency to be created or the motor speed. Moreover, a cosϕ control and the resulting voltage reduction causes the motor to be always operated in the optimum efficiency range (reduction of copper losses in the asynchronous motor). Advantages of the V/f eco V/f operating mode: Good robustness Easy parameter setting High energy efficiency (lower heating of the motor in partial load operational range) Same speed accuracy and maximum torques as with VFCplus Less noise generation of the motor with active voltage reduction Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 15

16 1. Recommendation: Set the energy-saving "V/f eco" V/f operating mode. 2. Option: Adjust parameters. After a Lenze motor has been selected (in Step 2 Motor selection), the suitable values are automatically transmitted to the controller (unless this option has been switched off in the Use motor's default values dialog box). Information on the individual parameters can be found in the table below. 3. Click Next. Parameter Info C00022 Imax in motor mode Maximum current in motor mode for all motor control modes C00021 Slip compensation A higher slip compensation results in a higher increase in frequency and voltage when the machine is under load. C00015 V/f base frequency The motor voltage increases linearly with the frequency until the base frequency is reached. From this value on, the motor voltage remains constant, the speed increases and the maximum torque decreases. C00016 Vmin boost Boost of the V/f voltage characteristic in the range of lower speeds or frequencies. This may increase the starting torque. 16 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

17 Step 6 Motor feedback Click Next (the Lenze setting can be retained). Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 17

18 Step 7 Holding brake Detailed information on how to parameterise the holding brake control can be found in the online help for the 8400 StateLine in the chapter entitled "Basic drive functions (MCK)". The documentation of the holding brake control contains safety instructions that must be observed! If the motor is provided with a holding brake: 1. Set the "Autom. controlled" mode for the brake control. This is the usual mode to control the holding brake. 2. Select the output via which the holding brake is triggered. If required, the polarity of the brake output signal can also be inverted. 3. Set application and release times. Every mechanical holding brake comes with a construction-conditioned application and release time which must be considered by the holding brake control. The application and release time of the Lenze holding brake is indicated in the supplied operating instructions in the "Technical data" chapter. 4. Option: Set further brake parameters. 5. Click Next. 18 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

19 Step 8 Brake chopper When electric motors are braked, the kinetic energy of the drive train is fed back into the DC circuit regeneratively. This energy leads to an increase in the DC bus voltage. In order to avoid overvoltage in the DC bus, several different strategies can be used. We recommend the use of brake choppers (brake transistors) integrated into the controller for braking operation. The required brake resistor is connected to the terminals RB1 and RB2 of the controller. Stop! If the connected brake resistor is smaller than required, the brake chopper can be destroyed! If no brake resistor or regenerative module is used, the overvoltage switch-off ("OU") may respond, e.g. in the case of short deceleration times during feedback operation. Detailed information on the different strategies and suitable protective measures can be found in the online help for the 8400 StateLine in the chapter entitled "Motor control (MCTRL) Braking operation/brake energy management". 1. Select the strategy for the brake energy management. 2. When using a brake resistor: Set the brake resistance and rated power. The values to be entered can be obtained from the nameplate of the brake resistor. 3. Option: Set further detailed data for the brake resistor. 4. Click Next. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 19

20 Step 9 Main setpoints of the traversing profile 1. Adjust travel profile to the application. Information on the individual parameters can be found in the table below. 2. Click Next. Parameter Info C00039/1 Fixed setpoint 1 The three fixed setpoints can be activated via the digital C00039/2 Fixed setpoint 2 inputs DI1 and DI2. The fixed setpoints are specified in [%] according to the reference speed. C00039/3 Fixed setpoint 3 C00012 Acceleration time - main setpoint In order to prevent jumps, the speed setpoint is led via a C00013 Deceleration time - main setpoint ramp generator with linear ramps. C00011 Reference speed All speed setpoint selections are provided in % and always refer to the set reference speed. C00105 Decel. time - quick stop In case of the "quick stop" request, the motor is brought to a standstill within the set deceleration time. 20 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

21 Step 10 Monitoring Stop! Motor overload monitoring I 2 xt motor monitoring does not provide full motor protection! As the motor utilisation calculated in the thermal motor model is lost after mains switching, for instance the following operating states cannot be detected correctly: Restarting (after mains switching) of a motor that is already very hot. Change of the cooling conditions (e.g. cooling air flow interrupted or too warm). A full motor protection requires additional measures as e.g. the evaluation of temperature sensors that are located directly in the winding or the use of thermal contacts. For the installation according to UL or UR, the safety instructions provided in the hardware manual must be observed! Among other things, the activation of the motor overload monitoring (I2xt) is required here. Danger! Monitoring of brake resistor In the Lenze setting (C00574 = "0: No Reaction"), the response of the monitoring function does not stop the braking process! In particular for applications such as hoists or applications with a DC-bus connection, it must be checked if a stopping of the braking process due to a setting of C00574 = "1: Fault" is permissible. Stop! Implement appropriate protective measures against thermal overload of the brake resistor! Examples: Parameterisation of an error response in C00574 and evaluation of the parameterised error message within the application or the machine control system. Interruption of the mains supply by means of the temperature contact at the brake resistor and a simultaneous activation of the mechanical brake. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 21

22 1. Set the trigger threshold and error response for the respective monitoring mode. Information on the individual parameters can be found in the table below. 2. If an error is displayed (display <> " "): Click to call the Error details dialog for a more detailed analysis. This dialog also serves to reset the error message after the error cause has been eliminated. 3. Click Next. Parameter Info C00120 Setting of motor overload (I 2 xt) Motor overload monitoring (I 2 xt): Overload threshold for motor utilisation meter (display in C00066). The overload threshold has to be set as follows: Rated motor current (C00088) C00120 = % Rated device current (C00098) C00606 Resp. to motor overload (I 2 xt) Motor overload monitoring (I 2 xt): Response when the motor load displayed in C00066 reaches the value " %". C00123 Device utilisat. threshold (Ixt) Monitoring of device utilisation (Ixt): C00604 Resp. to device overload (Ixt) Operating threshold and response when the operating threshold is reached. C00572 Brake resistor overload threshold Monitoring of brake resistor overload: C00574 Resp. to brake resist. overtemp. Operating threshold and response when the operating threshold is reached. 22 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

23 Step 11 Motor data identification The motor data identification serves to automatically identify the inverter characteristic, the influences of the motor cable and various motor parameters. Note! A motor data identification is mandatory if a newly created non-lenze motor (user motor) is connected to the controller. In all other cases, the motor data identification can be executed optionally in order to adapt the controller optimally to the connected motor. Danger! During motor data identification, the motor is energised via the outputs U, V and W of the controller! Detailed information on motor data identification can be found in the online help for the 8400 StateLine in the chapter entitled "Motor control (MCTRL) Motor selection/motor data". 1. If required (see notes): Execute a motor data identification. 2. Click Next. Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 23

24 Step 12 End 1. Click the Save parameter set... button to save the created configuration safe against mains failure in the controller (memory module). 2. Click Complete. Now, the setting of the most important parameters is completed. Tip! After the commissioning wizard is quit, save the»engineer«project for reuse: File Save 24 Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14

25 Switching on the controller and specifying the speed setpoint 1. Before switch-on: Make sure that the controller is inhibited (switch S1 open). 2. Switch on voltage supply of the controller. If the green "DRV-RDY" LED is blinking and the red "DRV-ERR" LED is off, the controller is ready to be enabled. 3. Enable controller: Close switch S1. Unless a fixed setpoint is active via the digital inputs DI1 and DI2, the drive now follows the speed setpoint specified via the setpoint potentiometer P1. Depending on the selected control mode, the following functions can be activated via the digital terminals DI1... DI4: Control mode "terminals" DI1 DI2 DI1 DI2 - DI1 DI2 Function/Info Overriding fixed setpoints Alternatively to the speed selection via the analog input, "fixed setpoints" (JOG values" can also be activated via the digital terminals. DI1 DI2 Function LOW LOW Speed selection via analog input 1 (terminal A1U) HIGH LOW Fixed setpoint 1 (C00039/1) LOW HIGH Fixed setpoint 2 (C00039/2) HIGH HIGH Fixed setpoint 3 (C00039/3) DI3 - DI2 - Manual DC-injection braking Manual DC-injection braking allows the drive to be quickly braked to a standstill without the need to use an external brake resistor. The braking current is set in C The maximum braking torque to be generated by the DC braking current is approx % of the rated motor torque. It is lower than that for braking in generator mode with an external brake resistor. - DI3 - - Quick stop function The quick stop function decouples the motor control from the setpoint selection. The motor is braked to standstill with the adjustable ramp time (n act = 0). DI4 DI4 DI1 - Change of direction of rotation DI3 Fail-safe selection of direction of rotation DI4 DI3 DI4 Function LOW LOW Quick stop HIGH LOW CW rotation LOW HIGH Counter-clockwise rotation HIGH HIGH No change - - DI3 DI4 - Motor potentiometer function This motor potentiometer function replaces a hardware motor potentiometer and can be used as an alternative setpoint source which is controlled via two inputs. DI3 DI4 Function LOW LOW No change HIGH LOW Increase speed LOW HIGH Decrease speed HIGH HIGH No change Lenze 8400 StateLine Quick start guide DMS 1.0 EN 08/2013 TD05/14 25

26 8400 StateLine Quick start guide EDS84AVSCxx DMS 1.0 EN 08/2013 TD05/14 Lenze Drives GmbH Breslauer Straße 3 D Extertal Germany +49 (0)51 54 / (0)51 54 / Lenze@Lenze.de Service Lenze Service GmbH Breslauer Straße 3 D Extertal Germany / (24 h helpline) +49 (0)51 54 / Service@Lenze.de L

Ä.H)oä. L-force Drives. Operating instructions. E84AVSCxxxxx. Inverter Drives 8400 StateLine C

Ä.H)oä. L-force Drives. Operating instructions. E84AVSCxxxxx. Inverter Drives 8400 StateLine C EDB84AVSC 13390878 L-force Drives Ä.H)oä Operating instructions 8400 E84AVSCxxxxx Inverter Drives 8400 StateLine C L Product key: Nameplate: Product range 8400 Inverter Drives E84 A V SC x xxx x x x x

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable.

Drive inverter for asynchronous AC motors without encoder feedback. The units are not option capable. MDX61B System overview MOVIDRIVE MDX60B/61B is the new generation of drive inverters from SEW EURODRIVE. The new series B MOVIDRIVE drive inverters, which feature a modular design, provide enhanced functions

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Inverter. "Actuator Torque" technology application for 8400 HighLine C and 8400 TopLine C _. Software Manual EN. Ä.O%ôä

Inverter. Actuator Torque technology application for 8400 HighLine C and 8400 TopLine C _. Software Manual EN. Ä.O%ôä Inverter 8400 "Actuator Torque" technology application for 8400 HighLine C and 8400 TopLine C _ Software Manual EN Ä.O%ôä 13460495 L Contents 1 About this documentation _ 3 1.1 Document history 3 1.2 Conventions

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

smd - frequency inverter 0.25 kw 4.0 kw

smd - frequency inverter 0.25 kw 4.0 kw SX03M-en1 EN Operating Instructions V0004 smd - frequency inverter 0.25 kw 4.0 kw Copyright 2005 Lenze AC Tech Corporation All rights reserved. No part of this manual may be reproduced or transmitted in

More information

EDK82EV Ä.8.ä. Information for the operator of the machine vector kw. E82xV251Kxxxxx... E82xV113Kxxxxx. Frequency inverter

EDK82EV Ä.8.ä. Information for the operator of the machine vector kw. E82xV251Kxxxxx... E82xV113Kxxxxx. Frequency inverter EDK82EV113.8. Ä.8.ä Information for the operator of the machine 8200 vector 0.25... 11 kw E82xV251Kxxxxx... E82xV113Kxxxxx Frequency inverter This documentation is valid for...... 8200 vector frequency

More information

MCH Series Drives Metasys N2 Communications Guide

MCH Series Drives Metasys N2 Communications Guide MCH Series Drives Metasys N2 Communications Guide About These Instructions This documentation applies to the use of an MCH Series Variable Frequency Drive with Metasys N2 protocol and should be used in

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

EDK94ARN24.P#T. L force Drives. Ä.P#Tä. Mounting Instructions A. E94ARNE0xx4. Regenerative power supply module

EDK94ARN24.P#T. L force Drives. Ä.P#Tä. Mounting Instructions A. E94ARNE0xx4. Regenerative power supply module EDK94ARN24.P#T L force Drives Ä.P#Tä Mounting Instructions 9400 13... 24 A E94ARNE0xx4 Regenerative power supply module !. Please read these instructions before you start working! Follow the enclosed safety

More information

smd - frequency inverter 0.37 kw 22 kw

smd - frequency inverter 0.37 kw 22 kw SL03L-en1 EN Operating Instructions smd401 smd - frequency inverter 0.37 kw 22 kw Copyright 2005 AC Technology Corporation All rights reserved. No part of this manual may be reproduced or transmitted in

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual Control Cabinet Inverter MOVITRAC B Functional Safety Edition 05/2009 16811216 / EN SEW-EURODRIVE Driving the world Content Content

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 2.00 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Revision 2.00 Optidrive P2 Advanced User Guide Rev 2.00 Optidrive P2 Parameter Set Overview 1 This Document

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Quick Start Guide. MOVIMOT MM..D With DRS/DRE/DRP AC Motor

Drive Technology \ Drive Automation \ System Integration \ Services. Quick Start Guide. MOVIMOT MM..D With DRS/DRE/DRP AC Motor Drive Technology \ Drive Automation \ System Integration \ Services Quick Start Guide MOVIMOT MM..D With DRS/DRE/DRP AC Motor Edition 02/2013 20099347 / EN SEW-EURODRIVE Driving the world General information

More information

Ä.B&mä. Global Drive kw. efesotomasyon.com - Lenze. Information for the operator of the machine. EVF9330 xv...

Ä.B&mä. Global Drive kw. efesotomasyon.com - Lenze. Information for the operator of the machine. EVF9330 xv... EDKVF93 03.B&m efesotomasyon.com - Lenze Global Drive Ä.B&mä Information for the operator of the machine 9300 45... 90 kw EVF9330 xv... EVF9333 xv Frequency inverter EVF9330, EVF9331 9300vec156 EVF9332,

More information

EDKVS93 01.MñP. Ä.MñPä. Information for the operator of the machine kw. EVS9321 xx... EVS9326 xx.

EDKVS93 01.MñP. Ä.MñPä. Information for the operator of the machine kw. EVS9321 xx... EVS9326 xx. EDKVS93 01.MñP Ä.MñPä Information for the operator of the machine 9300 0.37... 11 kw EVS9321 xx... EVS9326 xx Servo controller 9300std078 Key for overview Position Description Controller Fixing rails for

More information

EDS94AYAB.;2G. L force Drives. Ä.;2Gä. Manual E94AYAB SM100. Safety module

EDS94AYAB.;2G. L force Drives. Ä.;2Gä. Manual E94AYAB SM100. Safety module EDS94AYAB.;2G L force Drives Ä.;2Gä Manual 9400 E94AYAB SM100 Safety module Please read these instructions and the documentation of the standard device before you start working! Observe the safety instructions

More information

EDK94PNE245.P#S. L force Drives. Ä.P#Sä. Mounting Instructions A. E94APNExxx4. Power supply module

EDK94PNE245.P#S. L force Drives. Ä.P#Sä. Mounting Instructions A. E94APNExxx4. Power supply module EDK94PNE245.P#S L force Drives Ä.P#Sä Mounting Instructions 9400 100... 245 A E94APNExxx4 Power supply module !. Please read these instructions before you start working! Follow the enclosed safety instructions.

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Revision 1.10 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Revision 1.10 Optidrive P2 Parameter Set Overview 1 This Document is for use with version 1.20 Firmware. Advanced

More information

EDKVS93 01.B&J. Ä.B&Jä. Information for the operator of the machine kw. EVS9321 xx... EVS9326 xx.

EDKVS93 01.B&J. Ä.B&Jä. Information for the operator of the machine kw. EVS9321 xx... EVS9326 xx. EDKVS93 01.B&J Ä.B&Jä Information for the operator of the machine 9300 0.37... 11 kw EVS9321 xx... EVS9326 xx Servo controller 9300std078 Key for overview Position Description Controller Fixing rails for

More information

Motor controller MCP24

Motor controller MCP24 Motor controller MCP24 Operating Instructions No portion of this documentation may be reproduced or made available to third parties without the express written permission of MTA-Systems GmbH. We have compiled

More information

8200 vector frequency inverter

8200 vector frequency inverter 8200 vector frequency inverter 0.25... 90.0 kw Lenze Global Drive Created as a system 8200 vector created as a system A universal product range offering all you need for user-friendly operation, diagnostics

More information

Operating comfort redefined Frequency Inverters M-MAX

Operating comfort redefined Frequency Inverters M-MAX Operating comfort redefined Frequency Inverters M-MAX The complete range of contac tors, efficient motor starters and variable speed drives for the motor circuit. New simple to install solutions based

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. CCU Universal Module Application Module

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. CCU Universal Module Application Module Drive Technology \ Drive Automation \ System Integration \ Services Manual CCU Universal Module Application Module Edition 05/2011 17061210 / EN SEW-EURODRIVE Driving the world Contents Contents 1 General

More information

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06

AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP Volt 1 & 3 Phase. Advanced User Guide Issue 06 AC Variable Speed Drive 0.75kW 250kW / 1HP 350HP 200 480 Volt 1 & 3 Phase Advanced User Guide Issue 06 About this Advanced Technical Manual 1 Revision History Issue Note Section Date 1.00 First Release

More information

Unidrive M400 (Frame 1 to 4) Quick Start Guide

Unidrive M400 (Frame 1 to 4) Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. For more detailed installation information, please refer to the Unidrive M400 User Guide which is

More information

GHB EN.88$ Ä.88$ä. Hardware Manual. E931Ex. Servo inverters for extra low voltages

GHB EN.88$ Ä.88$ä. Hardware Manual. E931Ex. Servo inverters for extra low voltages GHB 13.0001 EN.88$ Ä.88$ä Hardware Manual E931Ex Servo inverters for extra low voltages Please read these instructions before you start working! Follow the enclosed safety instructions. Overview 931E 002.iso

More information

Inverter. "Position Sequencer" technology application for 8400 TopLine C _. Software manual EN. Ä.Oiøä

Inverter. Position Sequencer technology application for 8400 TopLine C _. Software manual EN. Ä.Oiøä Inverter 8400 "Position Sequencer" technology application for 8400 TopLine C _ Software manual EN Ä.Oiøä 13467299 L Contents 1 About this documentation _ 3 1.1 Document history 3 1.2 Conventions used 4

More information

Firmware Manual - EC Series Drives

Firmware Manual - EC Series Drives 1 Firmware Manual - EC Series Drives Doc Ver 1.01 Firmware ver: EC series drives For installation details refer to Hardware Manual Safety: Read safety instruction in hardware manual before installation

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

8200 vector frequency inverter

8200 vector frequency inverter 8200 vector frequency inverter 0.25... 90.0 kw Lenze Global Drive Created as a system 8200 vector created as a system A universal product range offering all you need for user-friendly operation, diagnostics

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

ECS servo system MCS servo motors

ECS servo system MCS servo motors ECS servo system MCS servo motors for multi-axis applications Lenze Global Drive dynamic, powerful, compact ECS, MCS dynamic, powerful, compact The ECS servo system Servo drives with a high overload capacity

More information

MC3000 Series Drives Metasys N2 Communications Guide

MC3000 Series Drives Metasys N2 Communications Guide MC3000 Series Drives Metasys N2 Communications Guide About These Instructions This documentation applies to the use of an MC3000 Series Variable Frequency Drive with Metasys N2 protocol and should be used

More information

Tml - flux vector drive 0.25 kw 2.2 kw

Tml - flux vector drive 0.25 kw 2.2 kw TL03B-en EN Operating Instructions 1k...10k COM AIN +10V+12V 7 8 9 20 28 E1 E2 E3 K14 K12 Tml001 Tml - flux vector drive 0.25 kw 2.2 kw Contents About these instructions...2 1 Safety information...3 1.1

More information

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content 7 Set-up and maintenance 7.1 Functional testing....10 7.2 Maintenance...10 EN Operating instructions.............pages 1 to 6 Original 8 Disassembly and disposal 8.1 Disassembly....10 8.2 Disposal...10

More information

Assembly instruction / User manual

Assembly instruction / User manual Assembly instruction / User manual 4-Q motor speed control unit digital, type DLR 24/xx-466 Technical data under reserve technical changes Please read these instruction before using and please keep safe

More information

Operating Instructions

Operating Instructions Innovative by tradition. Operating Instructions Control Unit SG-RSV 239 Version 1 1003986 SG-RSV 239/24 24 V= 1005372 SG-RSV 239/36 36 V= 1003271 SG-RSV 239 50-150 V= Mayser GmbH & Co. KG Örlinger Straße

More information

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink Product datasheet Characteristics ATV12H075M3 variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - with heat sink Complementary Main Range of product Altivar 12 Product or component type Product

More information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide

Unidrive M200, M201 (Frame 1 to 4) Quick Start Guide This guide is intended to provide basic information required in order to set-up a drive to run a motor. Please refer to the Unidrive M200 / M20 User Guide which is available to download from www.controltechniques.com/user

More information

Functional data Factory settings Variable Setting Torque Inhibiting torque

Functional data Factory settings Variable Setting Torque Inhibiting torque echnical data sheet GK4A-MF Parameterisable SuperCap rotary actuator with emergency setting function and extended functionalities for adjusting air dampers in ventilation and air-conditioning systems for

More information

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717* Drive Technology \ Drive Automation \ System Integration \ Services *23494050_0717* Manual Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety Edition 07/2017 23494050/EN SEW-EURODRIVE

More information

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

Controller CMXH. Description STO. Safe Torque Off (STO) [ ] Controller CMXH Description STO Safe Torque Off (STO) 8062612 1603 [8062614] CMXH Translation of the original instructions CMXH-STO-EN Identification of hazards and instructions on how to prevent them:

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

Manual. MOVIDRIVE MDX60B / 61B Crane Control Application. Edition 01/ / EN

Manual. MOVIDRIVE MDX60B / 61B Crane Control Application. Edition 01/ / EN Gearmotors \ Industrial Gear Units \ Drive Electronics \ Drive Automation \ s MOVIDRIVE MDX60B / 61B Crane Control Application Edition 01/2007 11537817 / EN Manual SEW-EURODRIVE Driving the world Contents

More information

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink Characteristics variable speed drive ATV12-2.2kW - 3hp - 200..240V - 3ph - with heat sink Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

smd - frequency inverter 0.37 kw 22 kw

smd - frequency inverter 0.37 kw 22 kw SL03Q-en1 EN Operating Instructions smd401 smd - frequency inverter 0.37 kw 22 kw Copyright 2005 Lenze AC Tech Corporation All rights reserved. No part of this manual may be reproduced or transmitted in

More information

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate Characteristics variable speed drive ATV12-0.37kW - 0.55hp - 100..120V - 1ph - on base plate Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010 SINAMICS G120 Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F Function Manual Safety Integrated 07/2010 SINAMICS Answers for industry. Safety Integrated Function Manual,

More information

Operating Instructions

Operating Instructions EDB8274UB 00391883 Operating Instructions S2S1 20 28 E1 E2 E3 E4 39 PTC module Type 8274IB These Operating Instructions are valid for modules with the following nameplate data: 8274IB.0x combined with

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

vacon nx ac drives brake chopper unit (bcu) application user s manual

vacon nx ac drives brake chopper unit (bcu) application user s manual vacon nx ac drives brake chopper unit (bcu) application user s manual 2 vacon Introduction Vacon Brake Chopper Unit application INDEX Document code: DPD01565A Software code: ABFIFF01V113 Date: 27.3.2014

More information

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

ATV12H018M2 variable speed drive ATV kW hp V - 1ph Characteristics variable speed drive ATV12-0.18kW - 0.25hp - 200..240V - 1ph Complementary Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1 FSO Webnair FSO Safety Functions Module February 11, 2015 Slide 1 Competence Requirements for ABB Commissioner / Service Engineer of ACS880 Drives with FSO The integrated Safety Function Module (FSO; option

More information

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety Drive Technology \ Drive Automation \ System Integration \ Services Manual MOVITRAC Functional Safety Edition 12/2011 19396414 / EN SEW-EURODRIVE Driving the world Contents Contents 1 General Information...

More information

Matsushita. VF-C Compact. Inverter NEW: - Ultra-compact - Latest technology - Cost effective. Configurator software Motion Control Ver.1.

Matsushita. VF-C Compact. Inverter NEW: - Ultra-compact - Latest technology - Cost effective. Configurator software Motion Control Ver.1. Matsushita NEW: Configurator software Motion Control Ver.1.3 VF-C Compact Inverter - Ultra-compact - Latest technology - Cost effective VF-C inverter - a new generation for the 0.25 kw to 4.0 kw power

More information

VARIABLE SPEED DRIVES

VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...75kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging

More information

Operating Instructions

Operating Instructions Gearmotors \ ndustrial Gear Units \ Drive Electronics \ Drive Automation \ Services MOVTRAC B Keypad Edition 2/27 11586214 / EN Operating nstructions SEW-EURODRVE Driving the world Contents 1 mportant

More information

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3 Operating Instructions Control Unit SGRST 153 Version 0.3 1004931 SGRST 153 Original instructions GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel.: +49 731 20610 Fax: +49 731 2061222 EMail: info.ulm@mayser.com

More information

L-force. Inverter Drives 8400 protec. On site and all systems go!

L-force. Inverter Drives 8400 protec. On site and all systems go! L-force Inverter Drives 8400 protec On site and all systems go! 2 L-force Decentralised drives 2 The major challenges of the future are to be found in the areas of cost efficiency, time-saving and quality

More information

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate

ATV12P075M3 variable speed drive ATV kW - 1hp V - 3ph - on base plate Characteristics variable speed drive ATV12-0.75kW - 1hp - 200..240V - 3ph - on base plate Main Range of product Altivar 12 Product or component type Product destination Product specific application Assembly

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Characteristics variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination

More information

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase Characteristics variable speed drive ATV310-3 kw - 4 hp - 380...460 V - 3 phase Complementary Product destination Main Range of product Altivar Easy 310 Product or component type Product specific application

More information

Ä!Nndä. Information for the operator of the machine/system. Global Drive Series 9300 vector 0.37 kw kw. EDKVF9333!Nnd

Ä!Nndä. Information for the operator of the machine/system. Global Drive Series 9300 vector 0.37 kw kw. EDKVF9333!Nnd EDKVF9333!Nnd Ä!Nndä L Information for the operator of the machine/system Global Drive Series 9300 vector 0.37 kw... 110 kw This documentation is valid for controller types 9300 vector control as from

More information

igus motion Plastics dryve D3, DC-Motor Control System

igus motion Plastics dryve D3, DC-Motor Control System igus motion Plastics dryve D3, DC-Motor Control System Manual V 1.1 Website Shop www.igus.eu/d3 Videos/Tutorials www.igus.eu/dryve/tutorial Operating Manual dryve D3 - V1.1 1/15 Table of contents Table

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

SECTION VARIABLE FREQUENCY DRIVES

SECTION VARIABLE FREQUENCY DRIVES PART 1 GENERAL 1.01 DESCRIPTION This specification section establishes the requirements for variable frequency motor drives. The associated motor(s) shall be specified separate from the drive and listed

More information

3 CU240E-2 6SL3244-0BB12-1BA1 3 CU240E-2 DP 6SL3244-0BB12-1PA1. RS485/USS 6 3 (opt. per 2 DI) 3 CU240E-2 F 6SL3244-0BB13-1BA1

3 CU240E-2 6SL3244-0BB12-1BA1 3 CU240E-2 DP 6SL3244-0BB12-1PA1. RS485/USS 6 3 (opt. per 2 DI) 3 CU240E-2 F 6SL3244-0BB13-1BA1 Control Units CU240B-2, CU240E-2 Overview Safety Integrated functions The basic version of the CU240E-2 series (CU240E-2 and CU240E-2 DP) includes the safety function Safe Torque Off (STO) (certified according

More information

SMVector PROFIBUS-DP Communication Module Communications Interface Reference Guide

SMVector PROFIBUS-DP Communication Module Communications Interface Reference Guide SMVector PROFIBUS-DP Communication Module Communications Interface Reference Guide About These Instructions This documentation applies to the optional PROFIBUS-DP communications module for the SMVector

More information

Addendum to the System Manual. MOVIGEAR SNI Expanded Parameter Setting and Diagnostics with MOVITOOLS MotionStudio. Edition 01/ / EN

Addendum to the System Manual. MOVIGEAR SNI Expanded Parameter Setting and Diagnostics with MOVITOOLS MotionStudio. Edition 01/ / EN Drive Technology \ Drive Automation \ System Integration \ s MOVIGEAR SNI Expanded Parameter Setting and Diagnostics with MOVITOOLS MotionStudio Edition 01/2009 16641213 / EN Addendum to the System Manual

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

VARIABLE SPEED DRIVES

VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...110kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging

More information

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~ Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency Technical data sheet NKQ24A- SuperCap rotary actuator with emergency control function and extended functionalities for adjusting dampers in technical building installations and in laboratories Air damper

More information

DriveWare. User s Guide DriveConfig

DriveWare. User s Guide DriveConfig DriveWare User s Guide DriveConfig DriveConfig User s Guide 3AFE68910897 Rev B EN EFFECTIVE: 1.2.2008 2008 ABB Oy. All rights reserved. 5 Table of contents Table of contents...5 Introduction to the manual...7

More information

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC

GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, HP, 230V AC Software Start-Up and Reference Manual D2-3416-2 GV3000/SE General Purpose (Volts/Hertz) and Vector Duty AC Drive, 30-100 HP, 230V AC Version 6.04 Important User Information Solid-state equipment has operational

More information

Bus Regulation. PowerFlex 755 AC Drives. For Classroom Use Only!

Bus Regulation. PowerFlex 755 AC Drives. For Classroom Use Only! Bus Regulation PowerFlex 755 AC Drives For Classroom Use Only! Important User Information This documentation, whether, illustrative, printed, online or electronic (hereinafter Documentation ) is intended

More information

POWERDRIVE, PROXIDRIVE, VARMECA

POWERDRIVE, PROXIDRIVE, VARMECA M AI4+ AI4-7 8 + Diff V - A/D 2 bits Analog input 4 level 5.4 Scaling 5.4 5.4 X - 5 In This manual is to be given to the end user AI5 V A/D bits Analog input 5 level 5.44 Scaling 5.45 X - I AO6 2 -V 4-2

More information

Intelligent Operator Panel (IOP)

Intelligent Operator Panel (IOP) Safety notes 1 Overview 2 SINAMICS SINAMICS G110D, SINAMICS G110M, SINAMICS G120, SINAMICS G120C, SINAMICS G120D Operating Instructions Installation 3 Wizards 4 Control 5 Menu 6 Options 7 Technical data

More information

L-force Communication EDS84DMOTPBUS Ä.HSoä. Communication Manual motec. E84DGFCPxxx. PROFIBUS Communication Unit

L-force Communication EDS84DMOTPBUS Ä.HSoä. Communication Manual motec. E84DGFCPxxx. PROFIBUS Communication Unit EDS84DMOTPBUS 13395078 L-force Communication Ä.HSoä Communication Manual 8400 motec E84DGFCPxxx PROFIBUS Communication Unit L 2 L EDS84DMOTPBUS EN 3.0-11/2011 Contents Contents 1 About this documentation.........................................................

More information

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY Technical Manual HA09 Issue 008 Parker SSD Drives, a division of Parker Hannifin Ltd. All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form

More information

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1

Polymer Electric. Operating Instructions. Control Unit SG-TRS 3X8. Version 1 Operating Instructions Control Unit SGTRS 3X8 Version 1 100597 SGTRS 318 110 V= 100596 SGTRS 38 4 V= Original instructions GmbH & Co KG Örlinger Straße 1 3 89073 Ulm GERMANY Tel: +49 731 0610 Fax: +49

More information

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction ACOPOSinverter P74 User's Manual Version: 2.20 (August 2016) Model no.: MAACPIP74-ENG Original instruction All information contained in this manual is current as of its creation/publication. We reserve

More information

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date: Documentation Fan cartridge for EtherCAT and Bus Terminals Version: Date: 1.5 2017-08-07 Table of contents Table of contents 1 Foreword... 5 1.1 Notes on the documentation... 5 1.2 Safety instructions...

More information

VARIABLE SPEED DRIVES

VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES VARIABLE SPEED DRIVES 0.4...30kW THREE-PHASE COMPACT, VERSATILE HIGH PERFORMANCE Automatic car washing equipment APPLICA TION AREAS Packaging Automatic and semi-automatic packaging

More information

Power consumption In operation At rest For wire sizing

Power consumption In operation At rest For wire sizing echnical data sheet Modulating damper actuator for adjusting air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx 08 m orque Nm

More information

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink Characteristics variable speed drive ATV32-7.5 kw - 400 V - 3 phase - with heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application Function

More information

SENSORLESS VECTOR CONTROL

SENSORLESS VECTOR CONTROL D SERIES EM16 STANDARD DRIVE SENSORLESS VECTOR CONTROL EM16 STANDARD DRIVE SENSORLESS VECTOR CONTROL 1 2 SERIES 1 2 page 4 page 6 Introduction Fields of application 3 page 7 4 page 8 Designation Product

More information

Accessories PROFIBUS E94AYCPM. Servo Drives 9400 Communication Manual EN. Ä.K6ôä

Accessories PROFIBUS E94AYCPM. Servo Drives 9400 Communication Manual EN. Ä.K6ôä Accessories PROFIBUS E94AYCPM Servo Drives 9400 Communication Manual EN Ä.K6ôä 13422195 L Contents 1 About this documentation _ 5 1.1 Conventions used 7 1.2 Terminology used 8 1.3 Definition of the notes

More information

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V) E510 Compact Drive IP 20/ NEMA 1 0.5-40 HP (230V) 1-75 HP (460V) Control Mode Application & Selection Guide The E510 compact AC Drive is an easily configurable product that controls many motor driven applications.

More information

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064 Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window

More information

ST (6ES7132-6FD00-0BB1)

ST (6ES7132-6FD00-0BB1) SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ

More information

Technical data sheet. Technical data

Technical data sheet. Technical data echnical data sheet LMQ4A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx 8 m orque 4 Nm Nominal

More information

Ä.BNCä. Global Drive vector kw. Information for the operator of the machine EVF9335 EV... EVF9338 EV. Frequency inverter

Ä.BNCä. Global Drive vector kw. Information for the operator of the machine EVF9335 EV... EVF9338 EV. Frequency inverter EDKVF93 04.BNC Global Drive Ä.BNCä Information for the operator of the machine 9300 vector 110... 200 kw EVF9335 EV... EVF9338 EV Frequency inverter 1 2 3 4 7 5 X1 X3 K31K32 33 34 62 7 39 E5 E4 E3 E2 E1

More information

L-force Drives. SM301 safety module (E94AYAE) Parameter setting & configuration

L-force Drives. SM301 safety module (E94AYAE) Parameter setting & configuration EDS94AYAE 13303780 L-force Drives Ä.?Fqä Software Manual 9400 SM301 safety module (E94AYAE) Parameter setting & configuration L Overview - technical documentation for Servo Drives 9400 Overview - technical

More information