Speed indicator DR 1010 Revolution per minute - speed - flow
|
|
- Tiffany Jefferson
- 5 years ago
- Views:
Transcription
1 Speed indicator DR 1010 Revolution per minute speed flow Features M LEDDisplay 14.2 mm red M Display range M decimal points or floating point programmable M Inputs for switching contacts, pnpinitiators and Namurinitiators M Programmable inputprescaler M Time base min 1 M Integrated transmittersupply 24/8 V DC M Holdinput M Max. 2 outputs, SPDT relay M Field case with snap lid, 2 x M16x1.5 other cable glands see Option 09 or on request M Protection IP65 General The Speed Indicator DR1010 has been designed for field applications in process control and automation. Parameters for operation mode can be programmed. The DR1010 can be used wherever processes based per minute just as speed should be measured and displayed. Short information Programming Transmittersupply Input prescaler Alarm outputs Holdfunction Parameters are programmed via frontside membrane keypad The integrated transmitter supply allows direct connection of pnp initiators, light barriers, mechanical switch contacts, proximity switches, rotary encoder (24 V DC) and Namur initiators (8 V DC). An input prescaler function for both inputs is programmable. Alarm outputs can be programmed as continues contact or pulse contact. Switching performance min. or max., hysteresis, ondelay time and offdelay time are programmable in range from 1 s up to 9 h. Freezing the display by control voltage 24 V DC or voltage free contact. For more features like math functions summing, difference and display conversion, etc. please choose ProductivityMeter PR
2 Technical data Power supply Supply voltage : 230 V AC ±10 %; 115 V AC ±10 %; 24 V AC ±10 % or 24 V DC ±15 % Power consumption : max. 3.5 VA Operating temperature : C/ F, Standard (extended temperature range on request) Rated voltage : 250 V~ acc. VDE 0110 between input/output/supply voltage overvoltage category III Test voltage : 4kV=, between input/output/supply voltage conformity : EN55022, EN60555, IEC /4/5/11/13 Input pnp input : Ri = 6.3 kω level: < 4 V low; > 8.5 V high; hysteresis > 2.5 V, max. 35 V Namur input : Ri appr. 1 kω (<4 ma) level: < 1 ma low; >2.2 ma high; hysteresis > 0.5 ma max. 35 V Counting frequence max. : Input E1 = 1 Hz Hz, (switch contact) Input E2 = 1 Hz khz, (pnpinitiator or Namur) Accuracy : %, ±1 Digit Min. pulse width : Electronic pulse 50 μs, switch contact 5 ms Transmitter supply : 8 V DC (Namur), 24 V DC (pnp), Ri appr. 150 Ω, max. 50 ma Display : LED red, 14.2 mm Indicating range : Digit with leading zero suppression Additional display : LED 2digit red, 7 mm (parameter and output indicator ) Output Relay : SPDT <250 V AC <250 VA <2 A, <300 V DC <50 W <2 A Field case : Material PA6GF 15/15 Weight : max. 350 g Connection : Clamp terminals, 2 mm² wire, 1.5 mm² flexible wire, AWG14 Protection : Front IP65, terminals IP20, fingersafe acc. BGV A3 Dimensions Option 09 1 x M20x1.5 Multi (2 x Ø=6 mm) 1 x M20x1.5 2 x M16x1.5 (In the base on request) 2
3 Legend (open lid) Terminal strip Terminal 1 and 13 not marked Connection diagram Alarm outputs E1 (30 Hz) E2 (15 khz) GND Hold +24/8 V max. 50 ma 250 V AC < 250 VA <2 A 300 V DC < 50 W < 2 A A1 A2 Switch contact NamurInitiator (8 V DC) Supply voltage e.g. 230 V AC PNPInitiator rotary encoder (24 V DC) 3
4 Controls and indicators Process value Field for additional text Parameter display or activated preselect outputs Description Unitfield Parameter button Down button Up button. For se Operation of the device is arranged in 2 levels. The requested parameter can be called by button lection within a parameter or for entering data, use buttons and. Button combinations: + 1 parameter back + setting parameter to zero or minimum value After switching on the supply voltage, the device is located in the Working level. Setpoint of the alarm outputs can be adjusted. Pressing the button for more than 2 seconds, activates the Configuration level. Now all the parameters which definines the function of the device can be programmed. After finishing the configuration or when no button was pushed for more than 2 minutes, the program returns to the working level. Leaving the configuration level is possible at any time by pressing the button for more than 2 seconds. Parameter display as status indicator for the alarm outputs A1A2. Error codes: Segments f (A1) and/or b (A2) are flashing with 2 Hz, when delay time is active. Segments e (A1) and/or c (A2) are output indicators. Reading this message in the parameter display a parameter failure has been occured. The display flashes. By pressing one of the buttons, the error code will be deleted and a copy of the factory settings will be reloaded to the EEPROM. The device will work with the factory settings. If this copy doesn t work, please ship the device for factory repair. Parameter lock active. See configuration page 7. Overflow Startup note: Before the device can be used, it must be configured for the intended use. see page 5 4
5 Notes to representation Parameter is only displayed when configurated Parameter is only displayed when feature is included (see order code) Please Note: All parameters can be called if they are not blocked by other programmed parameters and if they are available. Factory settings are shown in the configuration level in the display. Working level Button Display Description Process value Output indication (only if installed and activated). Setpoint alarm output A1 Setting possible from... Digit Setpoint alarm output A2 Setting possible from... Digit with buttons und. 5
6 Configuration Button Display Description (Display graphic shows factory settings) Press 2s 1 Transmitter supply / input level : 24V DC für pnpinitiators : 8V DC für NamurInitiators* (* with ext. 5V supply also useful for TTLsignals) : only for factory settings Selection 2 Prescaler for input E1 and E2 Setting possible from...digit (Only every n th pulse is displayed) 3 Decimal point position : floating point : 3 decimals : 2 decimals : 1 decimal : non Maximum 3 decimal point positions possible. In the mode the decimal point changes automatically if the process value > digit Selection 4 Digital filter Selection with button and. 5 Switching performance for alarm output A1 (min) : cont. contact on off (max) : cont. contact off on Selection 6 Setpoint for alarm output A1 Setting possible from... Digit ( mode settings without decimals) 7 Hysteresis for alarm output A1 Setting possible from... digit ( mode settings without decimals). continue page 7 6
7 Button Display Description (Display graphic shows factory settings) 8 Switchon delay time for alarm output A1. Setting possible from... (h.mm.ss) 9 Switchoff delay time for alarm output A1. Setting possible from... (h.mm.ss) 10 Switching performance for alarm output A2 (min) : cont. contact on off (max) : cont. contact off on Selection 11 Setpoint for alarm output A1 Setting possible from... Digit ( mode settings without decimals) 12 Hysteresis for alarm output A2. Setting possible from... digit ( mode settings without decimals). 13 Switchon delay time for alarm output A2. Setting possible from... (h.mm.ss) 14 Switchoff delay time for alarm output A2. Setting possible from... (h.mm.ss) 15 Parameter lock : no lock : configuration level locked : all parameters locked Selection Return to the working level 7
8 Ordering code DR Input 1 2 pulse inputs, integrated transmitter supply, hold input 2. Alarm output 00 not installed 2R 2 alarm outputs relay SPDT 3. Supply voltage V AC V AC 4 24 V AC 5 24 V DC ± 10 % 5060 Hz ± 10 % 5060 Hz ± 10 % 5060 Hz ± 15 % 4. Option without option 1 x M20x1.5 Multi (2 x Ø6mm), 1 x M20x Unit (appears in the unit field) 6. Additional text (will be placed in the field for additional text, max. 3 x 70 mm, WxH) Custom confuguration on request 8 10/04V1.600
Setpoint adjuster SG 1010 Output standard signals 0/ ma or 0/ V DC
Setpoint adjuster SG 1010 Output standard signals 0/4... 20 ma or 0/2... 10 V DC Features M LEDDisplay 14.2 mm red M Display range ± 9999(0) Digit M Indicating range and decimalpoint programmable M Setpoint
More informationStandard Signal Meter S 1010
GHMMesstechnik GmbH Standort Martens Kiebitzhörn 18 D22885 Barsbüttel / Germany +49(0)40670 730 Fax +49(0)40670 73288 info@martenselektronik.de www.ghmmesstechnik.de Standard Signal Meter S 1010 Industry
More informationSetpoint adjuster SG 9648 Output standard signals 0/ ma or 0/ V DC
adjuster SG 9648 Output standard signals 0/4... 20 ma or 0/2... 10 V DC Features M LEDDisplay 14.2 mm red M Display range ± 9999(0) digit M Indicating range and decimal point free programmable M Set point
More informationStandard-Signal-Panelmeter S 9648 Industry standard signals - integrated transmitter-supply - potentiometer
Martens Elektronik GmbH Kiebitzhörn 18 D22885 Barsbüttel/Germany www.martenselektronik.de F+49(0)40670 730 Fax +49(0)40670 73288 J info@martenselektronik.de StandardSignalPanelmeter S 9648 Industry standard
More informationUniversal counter UZ 9648 Counting - length measurement - metering - positioning
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Universal counter UZ 9648 Counting - length measurement - metering - positioning Features M LED-Display 14.2mm
More informationTank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement Features
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Tank-Display TA 1010 Content measurement for different formed tanks by hydrostatic pressure or distance measurement
More informationConductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells
Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells Features M LED-Display 14.2 mm red M Indicating range 2000(0) Digit M Measuring ranges programmable from 0... 2.000
More informationProcess displays For current and voltage
Features Voltage input TRMS-AC/DC up to 600 V Current input AC/DC 1 A, 5 A and shunt (precision resistor) 60 or 100 mv With 2 or 4 limits Display range can be linearised Min, Max, Hold functions 4 20 ma
More informationFACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D
FACTORY AUTOMATION Manual Speed Monitor KFU8-DW-.D With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services
More informationAmplifiers, Counters, Timers & Controls
Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter
More informationTemperature-Guard TG 50 Pt100/Pt Thermocouple J, K, N, S
Temperature-Guard TG 50 Pt100/Pt1000 - Thermocouple J, K, N, S Features M Input Pt100, Pt1000 and Thermocouples J, K, N, S M Measuring range programmable M Basic accuracy 0.1 % +/- 1 Digit M Simulator
More information02/11/2015
DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact
More informationElectronic timer CT-EAS ON-delayed and OFF-delayed with 1 c/o contact Data sheet
2CDC 251 116 F0004 1 5 2 4 3 6 Characteristics Single-function ON-delay and OFF-delay timer One device includes 10 time ranges, from 0.05 s to 300 h, for the adjustment of the time delay Remote potentiometer
More information02/11/2015
48 x 48 Max. Counting Speed 5 KHZ Green backlit LCD display Part number 87629111 Counter, Preselection chronometer Maximum input frequency 5 k Hz Simple parameter setting, configuration using text menus
More informationPhase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE Ordering details
Phase loss monitor CM-PBE Phasemonitor for over and undervoltage CM-PVE 1SVR 550 882 F 9500 CM-PBE Yellow LED - state of relay voltage and single-phase supply voltage for phase failure Monitoring of neutral
More informationTechnical specifications
Technical specifications General information Operating temperature -25 to 60 C Storage temperature -40 to 70 C Enclosure type Panel installation (DIN IEC 61554) Enclosure fixing Screw-type clamping technology
More informationElectronic timer CT-AHD.22
2CDC 251 093 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationSafety Temperature Limiter TT-STL 50
GmbH Postal address: House address Fon (+49) 0 22 42-8703-0 Postbox 1261 Löhestr. 37 Fax (+49) 0 22 42-8703-20 http: // www.tematec.de 53759 Hennef 53773 Hennef e-mail: team@tematec.de Safety Temperature
More informationElectronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet
2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationElectronic timer CT-ERD.12
2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationDual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx
D224 Dual Channel Monitor for Measurement of Speed and Ratio with SIL1 requirements Series D224.xx D224 Front View KEY FEATURES SIL1 / IEC 61508:2010 compliant Dual Channel Speed and Ratio Monitor with
More informationMeasuring Amplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Measuring mplifier DMS 50 Weight - Force - Pressure - Torque with strain gauges Features M Bridge sensitivity
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet
2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More informationSSR - Supplies - Relays
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 SSR - Supplies - Relays System Solid State Relays from 25 up to 125 A Relay
More informationElectronic timer CT-ERS.21
2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width
More informationVEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA
Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationTachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50
List of content page Counters and indicators DA5-IU-C... 10 DA5-IU-2K-C... 12 DA5-IU-2K-V... 12 KCM-51-C... 14 KCM-51-V... 14 KCM-70-C... 16 KCM-70-V... 16 KCM-70A-C... 18 KCM-70A-V... 18 KCT-6S-C... 20
More informationElectronic timer CT-ARS.11
2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationZelio Count - Counters RC87610
Zelio Count - Counters RC87610 Catalog March 05 Class 9051 CONTENTS Description..............................................Page Product Description........................................... RC87610050
More informationDisplays Transducers. Displays and transducers
JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More informationVoltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationKTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters
Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More informationGeräte-Handbuch Device manual Notice pour utilisateurs
Geräte-Handbuch Device manual Notice pour utilisateurs R Multifunktionsanzeige und Auswertesystem Multifunction display and evaluation system Afficheur multifonctions et système d'évaluation AX360 Sachnr.
More informationData sheet ACT20P ACT20P-CMT-10-AO-RC-S. Phone: Fax: Web: - [!
-CMT-10-AO-RC-S [!-] General ordering data Type -CMT-10-AO-RC-S Order No. 1510470000 Version Current-measuring transducer GTIN (EAN) 4050118319583 Qty. 1 pc(s). -CMT-10-AO-RC-S Technical data Dimensions
More informationAnalog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)
Data Sheet 202560 Page 1/12 JUMO AQUIS 500 ph Transmitter/Controller for ph, ORP, NH 3 (ammonia) concentration and temperature Brief description The device is used for measuring/controlling the ph, ORP
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationPower Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41
6. 6.1 Order Data Model Number 4P3040.00-490 1) 0AC201.9 0MC111.9 0MC211.9 4A0034.00-000 4EX101.00 7TB712.9 7TB712.91 7TB712:90-02 7TB712:91-02 Short Description, 5.7 inch QVGA black/white LC display,
More informationControl elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.
On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationRE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O
Characteristics Ondelay Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing
More informationTime Counters mini "h", DC Version
Type 633-DC Time Counters mini "h", DC Version Type 633.0 Type 633.7 Type 633.8 High shock resistance Miniature dimensions Electrical connections in standard grid Suitable for PCB mounting Machine-solderable
More informationVEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA
4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status
More informationAnalog outputs Output 1 + 2: 0(4) 20 ma or 0 10 V. Configurable as - analog process value output - continuous controller output (PID action)
Page 1/10 JUMO AQUIS 500 ph Transmitter/Controller for ph, ORP, NH 3 (ammonia) concentration and temperature Brief description The instrument is used for measuring/controlling the ph, ORP or NH 3 (ammonia)
More informationController. Applications. Characteristics. Extruder machines Heating control systems Facility engineering Wide range of instrumentation
GHM GROUP CORPORATE GHM Messtechnik GmbH Schloßstr. 6 88453 Erolzheim GERMANY Phone +49 7354 937233-76 Fax +49 7354 937233-88 Controller Characteristics System Output Case 2-point-controller, 3-point-controller,
More informationEMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks
Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008
More informationInCos-P Pressure sensor 20 Pa Pa
InCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue Compact. Easy installation. Universal. Cost effective. Safe.
More informationLAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input Features Choice of 2-1/4", 4", 6" or 8" digit heights Choice of 4 or 6 digits with decimal points Choice of
More information02/11/2015
24 x 48 Hour CTR24 non-backlit model Part number 87622162 Display : 8-digit LCD, height 8 mm Built-in module for voltage inputs 10 260 VAC/DC () 4 timing ranges : 99,999.99 hrs - 99,999.59 hrs - 999,999.9
More informationMonitoring Relays can be used to monitor 3-phase power supplies with 3 or 4 wires simply by changing DIP switch settings.
Authorised Distributors:- Intech Systems Chennai Pvt. Ltd, Chennai-600 032 Ph: +91 44 4353 8888 Fax: 044 4353 7888 E-mail: info@intechchennai.com Website: www.intechchennai.com Three-phase Voltage Relay
More informationMPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS
MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control
More informationZelio Control - modular measurement and control relays 1 Speed control relays RM35 S
Presentation, description 1 Speed control relays M35 S 105687 Presentation Speed control relay M35 S0MW monitors: 2 Underspeed: without memory, with memory, 5 with inhibition by external contact. 2 Overspeed:
More informationBulletin 817 Thermistor Protection Relay
6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output
More informationTest devices and Multifunction timer relay
Test devices and Multifunction timer relay VARIOTEST ROTATEST CSG420 Test devices Industries VARIOTEST The Condor-VARIOTEST is a universal test instrument featuring acoustic signals for: P. 145 Testing
More informationElectronic timer CT-VWD Impulse-ON with 1 c/o contact Data sheet
Electronic timer CT-WD 2CDC 251 003 F0003 CT-WD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the pulse time 2 Potentiometer with direct reading scale for the fine
More informationMSR178DP. Description. Features. Specifications
MSR178DP Description The MSR178DP is a multi-function time-delay relay for use in safety circuits. It can be configured by the user to perform on-delay, offdelay or single-pulse modes. It is used for applications
More informationElectronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts The CT-APS.21 is an electronic timer from the CT-S range with OFF-delay. It provides 10 time ranges and a continuous rated control
More informationDINALOG A 144 x 36 A1400 Light-Strip Indicator
DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to
More informationSwitching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet
1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green
More informationFaults on the system Proximity switch connection technology:
Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches
More informationEMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.
Electronic monitoring relay for level monitoring of conductive liquids INTERFACE Data sheet 103073_en_04 1 Description PHOENIX CTACT - 09/2009 Features Increasingly higher demands are being placed on safety
More informationSupply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,
Data sheet SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA, Supply voltage Rated value (DC) 24 V DC Load voltage L+ Rated value (DC) permissible range, lower
More informationElectronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.
More informationYour process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this
Overview Signal converters Your process requires the utmost attention Our new signal conditioners support you in achieving this Many process parameters in your system are handled by your control system,
More informationElectronic timer CT-AWS Impulse-OFF with 2 c/o contacts Data sheet
CDC 51 1 F000 1 7 6 5 8 Characteristics Single-function impulse-off timer One device includes 10 time ranges, from 0.05 s to 00 h, for the adjustment of the pulse time c/o contacts nd c/o contact can be
More informationmxcontrol Multifunction Controller
mxcontrol Multifunction Controller Data and event logging One controller hardware with dozens of configuration possibilities quickly downloaded via SD card (supplied) or via USB interface Type 8620 can
More informationRotary Measuring Technology Absolute encoders, Multiturn, optional with incremental track
Electronic multiturn gear with intelligent sensing technology (IST) Integrative Technology Max. 4 programmable outputs* for the SSI version Programmable parameters include*: code type, resolution per revolution,
More informationModular Panel Meter Series EDM 35
Modular Panel Meter Series EDM 35 CONTENTS Page 1. Introduction 2 1.1 Getting Started 2 1.2 Overall Description 3 1.3 Features 3 1.4 Block Schematic 4 2. Unit Description 4 2.1 Modules 4 2.2 Main Unit
More informationSafety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor
Safety Relay F 121 Emergency-Stop Relay, Safety Gate Monitor Features M Safety-category 4 acc. to DIN EN954-1 M Stop-category 0 M Crossfault monitoring M Monitored start (On-switch) or automatic start
More informationRE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.
Characteristics universal plug-in timing relay - flashing - 0.1 s..60 mn - 24..240 V AC - 2 OC Main Range of product Product or component type Discrete output type Contacts type and composition Width pitch
More informationRE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC - 1 OC Complementary Contacts material Width pitch dimension Control type Voltage range Connections - terminals Housing material Main Range
More informationSingle-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable
70 Series - Line monitoring relay 70 Features 70.11 70.31 70.41 Electronic voltage monitoring relays for single and three-phase applications Multifunctional types, providing the flexibility of monitoring
More informationAS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input
ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x
More informationISOMETER isoev425 with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device
More information24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0
monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts
More informationElectronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationAbsolute Encoders Multiturn
The multiturn encoders 6 and 8, with interface and combined optical and magnetic sensor technology, offer a maximum resolution of 5 bits. These encoders are programmable via the Ezturn software. The hollow
More informationOTB1C0DM9LP I/O distributed module OTB - CANopen bus m
Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete
More informationPressure-Converter UNICON -P Differential pressure - diminished pressure - overpressure - barometric pressure - flow rate Features
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Pressure-Converter UNICON -P Differential pressure - diminished pressure - overpressure - barometric pressure
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationAlarm Unit DG 3200 Control And Monitor Standard Signals
Alarm Unit DG 3200 Control And Monitor Standard Signals With the Alarm Unit DG 3200 DRAGO is extending its offer on high-functional and high-reliable components of the interface technique. The Alarm Unit
More informationRE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O
Characteristics star-delta timing relay - 230VAC/440VAC - 1 C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts type
More informationETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description
(-PT) Multifunctional time relay with various functions and adjustable times Data sheet 106395_en_02 PHOENIX CONTACT 20-06-08 1 Description Requirements pertaining to safety and system availability increase
More informationOperating Instructions VEGAMET 381
Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...
More information96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply
gal/h Digital panel meter 4½digit DV4 Without setpoints Sensor supply status 22/05/06 panelmeteranalog_gb.doc page 9 Digital panel meter Direct voltage Direct current gal/h Direct voltage, direct current
More information-ment Ambient humidity 35 to 95%RH, Storage :35 to 95%RH
PRD/PRDW Series Long Distance type Long distance proximity Features Long sensing distance (. to times longer sensing distance guaranteed compared to existing models) Improved the noise resistance with
More information3RG7 Opto-BERO Photoelectric Proximity Switches
K 80 Sensing range 2 m (energetic sensor) Diffuse sensors Modulated infrared light DC or AC/DC M 12 plug or moulded plastic joint IP 67 ON-delay, OFF-delay, pulse shaping Timer 0.01 s to 10 s Enabling
More informationZelio Control-modular measurement and control relays 1
Presentation, description 1 106439 RM35 TM111MW Presentation Motor temperature measurement and 50MW and RM35 TM250MW monitor the following, on 3-phase supplies: correct sequencing of phases L1, L2 and
More informationRE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output
Characteristics on-delay timing relay - 1 s..100 h - 24..240 V AC/ DC - solid state output Main Range of product Product or component type Discrete output type Width Component name Time delay type Time
More informationLAUREL ELECTRONICS, INC.
LAUREL ELECTRONICS, INC. Laureate RTD Temperature Panel Meter / Controller Features Factory calibrated for 100Ω platinum, 10Ω copper & 120Ω nickel RTDs 2, 3 or 4-wire connection with lead resistance compensation
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationElectronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet
2CDC 251 002 F0003 CT-ERD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the time delay 2 Potentiometer with direct reading scale for the fine adjustment of the time
More informationRE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O
Characteristics On-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts
More informationRE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O
Characteristics Off-delay Timing Relay - 0.05s 300h - 24 240V AC/DC - 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Complementary Contacts
More information