E3 -> E1 Switching Demultiplexer

Size: px
Start display at page:

Download "E3 -> E1 Switching Demultiplexer"

Transcription

1 E3 -> E1 Switching Demultiplexer Model INT May 2001 Intronics, Incorporated 2020 Lafayette Boulevard Fredericksburg, Va (540) (Voice) (540) (Fax) intrnx.com

2 I N T R O N I C S, I N C. MODEL INT-2056 E3 -> E1 Switching Demultiplexer 12 May 2001 Copyright (c) 2001, Intronics, Incorporated ALL RIGHTS RESERVED Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

3 Table of Contents Paragraph Topic Page 1.0 Overview Functional Description Hardware Elements External Signal Interface Internal Configuration Options Preventive Maintenance Command and Control Remote Control Protocol On Line Help Facility INIT INFO DMUX STAT EQB SDFLT Specifications 13 Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

4 1.0 Overview The INT-2056 is a versatile switching demultiplexer for ITU/CEPT telecommunications standard E3 rate ( Mbps) PCM signals. It accepts 20 independent E3 inputs and allows the user to demultiplex and selectively output any 64 of the 320 possible E1 tributaries embedded within the E3 inputs. Optionally the unit also provides 20 E3 outputs. The user may select any E3 input to be routed to any one or more of these E3 outputs, providing a fully non-blocking 20 x 20 E3 switching capability. E3 switching is completely independent from E1 output selection. Control and status is provided via a 9- pin D connector serial port with signaling conforming to EIA standard RS-232C. Control and status via front panel or EtherNet are also available as options. The configuration of the unit maintained in non-volatile memory and the unit is restored to its prior operating state when power is applied. The unit is a 10 ½ high standard 19 rack mounted enclosure requiring 175 Watts of 120 VAC 50/60 Hertz power. 2.0 Functional Description A functional block diagram of the INT-2056 is shown on the following page. The unit accepts 20 E3 inputs. These must conform to the ITU/CCITT recommendations G.703 and G.751 for Mbps operation, and be AMI/HDB3 encoded. Inputs are unbalanced (single ended), accepting a 75 Ohm impedance coaxial cable via a BNC style connector. Cable equalization (per square root of frequency) is provided for various cable lengths and is selectable by the user for losses up to 13.2 db. The 20 E3 inputs are routed to four 16 channel E3 to E1 demultiplexer / selector cards and optionally to an E3 switching output card. Each of the E3 to E1 demultiplexer cards has a 20 input to 16 output non-blocking switch which allows any E3 input to be routed to any one or more of the 16 independent E3 to E1 demultiplexer channels on that card. Each demultiplexer channel accepts an E3 input, demultiplexes and outputs all 16 E1 tributaries embedded within that E3. These E1 tributaries are routed to a selector circuit where one of the 16 is selected and routed to an E1 output Line Interface Unit (LIU). E1 outputs conform to ITU/CCITT recommendation G.703 for Mbps operation, and are AMI/HDB3 coded. E1 outputs are balanced, 120-Ohm impedance for use with twisted pair cabling using a bayonette style Twinax connector. The optional E3 output card has a 20 input to 20 output non-blocking switch and allows any of the E3 inputs to be routed to any one or more of the twenty E3 output LIU s. E3 outputs conform to the ITU/CCITT recommendation G.703 for Mbps operation, and are unbalanced (single ended), providing a BNC style connector for a 75-Ohm impedance coaxial cable. Command and control is accomplished via an EIA standard RS-232C serial interface. It is compatible with an IBM/PC or equivalent serial port using a straight through cable with a 9-pin D style connector on each end. See the command and control section below for a detailed description of the command set. Control and status via front panel switches and EtherNet are also available as options. Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

5 Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

6 3.0 Hardware Elements The following items make up the INT-2056: 1. Modular chassis: The chassis is compatible with RETMA standard 19 rack mounting. It is 10 ½ high (6U) and 22.6 deep excluding connectors and handles. Mechanical drawings of the front and rear panels are shown on the following pages. The chassis has six slots in the rear panel that accommodate six 13 wide and 14 deep printed circuit cards. Cards may be installed and removed individually from the rear of the unit. The top card is the E3 input board followed by four E3 -> E1 demultiplexer output boards in the four slots below it. The optional E3 output board occupies the bottom chassis slot channel E3 input printed circuit board (1) channel E3 -> E1 demultiplexer output printed circuit boards (4) channel E3 output printed circuit board (1 optional). 3.1 External Signal Interface Twenty E3 rate inputs are accepted via 75 Ohm BNC connectors numbered 1 through 20 that extend through the mounting plate of the printed circuit board in the top slot of the unit. The first sixteen E1 rate outputs are made available via 120-Ohm Twinax connectors numbered 1 through 16 that extend through the mounting plate of the printed circuit board in the second slot of the unit. Similarly E1 rate outputs 17 through 32, 33 through 48 and 49 through 64 are made available from the cards in the next three slots. Optionally twenty E3 rate outputs are provided via 75 Ohm BNC connectors numbered 1 through 20 that extend through the mounting plate of the printed circuit board in the bottom slot of the unit. Remote control is available via a 9 pin D style connector permanently mounted on the left side of the unit. A/C power is accepted by the unit via a standard IEC style filtered power input module on the left side of the unit, and must be 120 VAC nominal 50/60 Hertz. 3.2 Internal Configuration Options The INT-2056 provides no user selectable internal on card configuration options. 3.3 Preventive Maintenance There are no routine maintenance procedures. No periodic alignments or adjustments are required. Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

7 Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

8 Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

9 4.0 Command and Control The INT-2056 may be configured by the user through the use of its RS-232 remote control interface. The configuration of the unit is stored in battery backed up memory at all times. It is preserved while the unit is powered down, or during a power failure, and is restored when power is applied. The front panel control switches and display are provided to enable this capability as a future system enhancement and are unused at this time. The front panel RESET switch is functional and restarts the embedded microprocessor. 4.1 Remote Control Protocol Remote control is accomplished via the RS-232 interface. Commands to and responses from the INT-2056 are in the form of either upper or lower case ASCII characters. Commands follow the format below and are terminated with a carriage return: ccccc xxx yyy zzz...etc...<cr> ccccc is the command verb xxx yyy zzz...etc... are command parameters The command verb and each parameter consist of one or more printable ASCII characters ( e.g. ASCII code > 20 hex ). The command verb and each parameter are separated by one or more non-printable characters such as a space (ASCII code 20 hex), or by a comma or equals character. Any separation characters before the command verb or after the last parameter are ignored. BS (backspace) or DEL (delete) erases the character immediately preceding it, and are useful in correcting keyboard entry errors After its initial power on message the unit maintains the "speak only when spoken to discipline", responding to commands and status queries that are received and prompting the user with a > character for the next command. Any command line beginning with a slash character is treated as a comment and ignored. The following response is sent when an invalid command has been received: <CR>ERROR: INVALID COMMAND <CR>><SP> Carr Rtn, >, Space The following response is sent when an invalid parameter has been received: <CR>ERROR: INVALID PARAMETER <CR>><SP> Carr Rtn, >, Space The following response is sent when a valid command has been completed: <CR>><SP> Carr Rtn, >, Space Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

10 It is not necessary for the user to enter all the parameters for a command. Parameters that are to the right of the last parameter entered are assigned their default values. This is a convenience that allows the user to avoid the necessity of typing parameter values that may rarely vary from their defaults On-Line HELP Facility The command verb HELP results in the following: > help Intronics, Inc. Model INT-2056 E3 / E1 Demultiplexer 08 Apr 01 Ver 1.00 Copyright (c) 2001, Intronics, Inc. ALL RIGHTS RESERVED INIT - Restart System INFO - Report Version DMUX - Connect E1 Output to E3 Input / Tributary STAT - Display Current DMUX Input to Output Connection EQB - Set E3 Rx Line Interface Unit Equalizer SDFLT - Set all E1 Outputs to Default E3 Input / Tributary HELP - Help Enter HELP.. for HELP about a specific command Where.. represents the command characters Example: HELP DMUX is help for the DMUX command INIT -- Resets and restarts the embedded control microprocessor. > help init INIT -- Resets and restarts the system. It is the same as initial power on or the reset switch INFO -- Reports the manufacturer, model, date and version of firmware. > help info INFO -- Reports the manufacturer, model, date and version of firmware. > info Intronics, Inc. Model INT-2056 E3 / E1 Demultiplexer 08 Apr 01 Ver 1.00 Copyright (c) 2001, Intronics, Inc. ALL RIGHTS RESERVED Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

11 4.2.4 DMUX Connects E3 inputs to E1 outputs. > help dmux DMUX -- Connect an E1 Output to an E3 Input / Tributary The command format is DMUX XX YY/ZZ. Examples: DMUX 12 4/14 or DMUX ALL 1/1 XX is the E1 output. This is the E1 output connector or ALL. Valid connector numbers are 1 through 64 YY is the E3 Input. This is the E3 input connector. Valid connector numbers are 1 through 20 ZZ is the tributary within the selected E3 to demux and output as E1. Valid tributaries are 1 through 16. > dmux 12 4/ STAT Display current DMUX E3 connection(s). > help stat STAT -- Display Current DMUX Input to Output Connection. The format of the command is STAT XXXX Example: STAT 12 or STAT ALL XXXX is the E1 output (1 through 64) or ALL > stat 12 E1 12 <= E3 04/14 > stat all OUTPUTS INPUTS /01 01/02 01/03 01/04 01/05 01/06 01/07 01/ /09 01/10 01/11 04/14 01/13 01/14 01/15 01/ /01 02/02 02/03 02/04 02/05 02/06 02/07 02/ /09 02/10 02/11 02/12 02/13 02/14 02/15 02/ /01 03/02 03/03 03/04 03/05 03/06 03/07 03/ /09 03/10 03/11 03/12 03/13 03/14 03/15 03/ /01 04/02 04/03 04/04 04/05 04/06 04/07 04/ /09 04/10 04/11 04/12 04/13 04/14 04/15 04/ EQB Set E3 Rx Line Interface Unit Equalizer. EQB -- Set E3 Rx Line Interface Unit Equalizer." ); The format of the command is EQB XX Y" ); Example: EQB 12 1 or EQB ALL 3" ); > eqb all 1 XX is the E3 Input. This is the E3 input connector." ); Valid connector numbers are 1 through 20 or ALL" ); YY is the equalizer setting (1-4):" ); 1 0.0dB < cable < 3.5 db (short cables)" ); 2 2.6dB < cable < 8.0 db" ); 3 6.0dB < cable < 9.9 db" ); 4 8.6dB < cable < 13.2 db (long cables)" ); Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

12 4.2.7 SDFLT Connects all E1 outputs to default E3 / Tributary Inputs. > help sdflt SDFLT -- Connect E1 outputs to default E3 / Tributary inputs. The format of the command is SDFLT Defaults are: E1 Outputs 1-16 <= E3 Input 1 Tribs 1-16 E1 Outputs <= E3 Input 2 Tribs 1-16 E1 Outputs <= E3 Input 3 Tribs 1-16 E1 Outputs <= E3 Input 4 Tribs 1-16 > sdflt Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

13 5.0 Specifications E3 Input Signals Definitions Number of Inputs 20 Connector Type BNC Connector P/N Trompeter UCBBJR29 Impedance 75 Ohms, Unbalanced, Single Ended Recommended Cable Coaxial ITU/CCITT Standards G.703, G.751 Bit Rate Mbps nominal Coding AMI/HDB3 E1 Output Signal Definitions Number of Outputs 64 Connector Type Twinax Connector P/N Trompeter CBBJR79, Bayonette, 3 Lugs Impedance 120 Ohms, Balanced, Differential Recommended Cable Shielded Twisted Pair ITU/CCITT Standards G.703, G.704 Bit Rate Mbps nominal Coding AMI/HDB3 E3 Output Signals Definitions Number of Outputs 20 (optionally installed card) Connector Type BNC Connector P/N Trompeter UCBBJR29 Impedance 75 Ohms, Unbalanced, Single Ended Recommended Cable Coaxial ITU/CCITT Standards G.703, G.751 Bit Rate Mbps nominal Coding AMI/HDB3 Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

14 Remote Control Interface DB-9F Remote Control RS-232C, 19,200 Bps 1 Start, 1 Stop, No Parity (Cable Pin for Pin Straight Through to IBM-PC) Pin 1 DCD (Connected to Pins 4 and 6) Pin 2 RXD Serial Data Output from INT-2056 Pin 3 TXD Serial Data Input to INT-2056 Pin 4 DSR (Connected to Pins 4 and 6) Pin 5 GND Pin 6 DTR (Connected to Pins 4 and 6) Pin 7 RTS Handshake to INT-2056 Pin 8 CTS Handshake from INT-2056 Pin 9 RI Unused Physical Size Weight Power Operating Temp Storage Temp Rack Mount (19 ), 6U (10.50 ) high 20 lb. 175 Watts (nominal) 0 50 degrees C (Non-Condensing) degrees C (Non-Condensing Intronics, Inc Lafayette Blvd. Fredericksburg, VA (540) Fax (540)

PCI ITU/CEPT E1 Demultiplexer

PCI ITU/CEPT E1 Demultiplexer PCI ITU/CEPT E1 Demultiplexer Model INT-9951 15 March 2001 Intronics, Incorporated 2020 Lafayette Boulevard Fredericksburg, Va 22401 (540) 898-4518 (Voice) (540) 898-3603 (Fax) http://www.intrnx intrnx.com

More information

Appendix A Cable Pinouts

Appendix A Cable Pinouts Appendix A Cable Pinouts This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module 163 CT1 and CE1 I/O Modules

More information

Cable Pinouts. SRP I/O Module

Cable Pinouts. SRP I/O Module Cable Pinouts A This appendix lists the cables and connector pinout assignments for the cables used with the ERX-7xx models and ERX-14xx models. Topic Page SRP I/O Module A-1 CT1 and CE1 I/O Modules A-4

More information

Cisco ONS CL Shelf Assembly Hardware

Cisco ONS CL Shelf Assembly Hardware CHAPTER 1 This chapter provides a description of Cisco ONS 15310-CL shelf hardware. Instructions for installing equipment are provided in the Cisco ONS 15310-CL and Cisco ONS 15310-MA Procedure Guide.

More information

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards.

Frame Relay Cabling This section describes the cabling and connector pinouts for the Frame Relay cards. A P P E N D I X B Cabling Summary Introduction This appendix contains details on the MGX 8850 cabling. Note In all cable references, the transmit direction is away from the switch, and the receive direction

More information

I/O Interface DNA300

I/O Interface DNA300 DNA300 OPERATIONS MANUAL 1 Ring Communications, Inc. Crisis Alert System I/O Interface DNA300 2 DNA300 OPERATIONS MANUAL 2006/06/13 DNA300 OPERATIONS MANUAL 3 Contents INTRODUCTION... 5 INSTALLATION...

More information

Select a Data Communication Interface

Select a Data Communication Interface Printer Setup and Operation Select a Data Communication Interface Select a Data Communication Interface You may connect your print engine to a computer using one or more of the available connections. The

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This section describes the Catalyst 4224 Access Gateway Switch ports and the cables and adapters used to connect the switch to other devices. This section includes the following topics: Console

More information

SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL

SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL SCI-2144 SYSTEM CONTROL INTERFACE MODULE OPERATOR S MANUAL SIGMA ELECTRONICS, INC. P.O. Box 448 1027 COMMERCIAL AVENUE EAST PETERSBURG, PA 17520 (717) 569-2681 SCI-2144 CONTENTS PAGE INTRODUCTION 2 RS-232

More information

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800

CPM Series. Control Port Manager. User's Guide. Models CPM-1600 and CPM-800 WTI Part No. 12348 Rev. B CPM Series Control Port Manager Models CPM-1600 and CPM-800 User's Guide 5 Sterling Irvine California 92618 (949) 586-9950 Toll Free: 1-800-854-7226 Fax: (949) 583-9514 http://www.wti.com

More information

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas.

ICD200A Quick Start Guide. Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Industrial Opto-Isolated RS-232 to RS-422/485 Converter Convert RS-232 data signals to RS-422/485 signals in heavy industrial areas. Rugged IP30-rated metal case for panel mounting. Quick Start Guide Customer

More information

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem ZM56 High-Speed Industrial Modem Command Summary 1 ZM56 High-Speed Industrial Modem AT Command Summary Command AT ATA ATDT ATE0 ATE1 ATH ATH1 ATI ATO ATS Description Attention Prefix Precedes all commands

More information

ZM24x Quick-Connect Industrial Modem. User s Manual

ZM24x Quick-Connect Industrial Modem. User s Manual ZM24x Quick-Connect Industrial Modem User s Manual Version 1.1 2004 ZYPEX, Inc. All Rights Reserved 1 ZM24x Quick-Connect Industrial Modem Since the equipment explained in this manual has a variety of

More information

The specifications for the Cisco 7304 router are listed in Table A-1.

The specifications for the Cisco 7304 router are listed in Table A-1. APPENDIX A This appendix provides system and component specifications for the Cisco 7304 router. The following topics are found in this appendix: System, page A-1 Processor and Memory and Configurations,

More information

NPort 6600 Series Quick Installation Guide

NPort 6600 Series Quick Installation Guide NPort 6600 Series Quick Installation Guide Edition 10.0, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

DPS-NEAT SJ-2 & SJ-3 RS-232 SERIAL JOYSTICKS

DPS-NEAT SJ-2 & SJ-3 RS-232 SERIAL JOYSTICKS DPS-NEAT SJ-2 & SJ-3 RS-232 SERIAL JOYSTICKS Operators Manual Version 1.2 Two axis (SJ-2) and three axis (SJ-3) versions 9600 baud, RS-232 serial output Uncommitted toggle and momentary push-buttons The

More information

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual

F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual F5-45x3/85x3 10/100Mbps Ethernet to 4E1/8E1 Converter User Manual (Version 1.1) Beijing Fibridge Co., Ltd. Content 1. Overview... 3 2. Features... 4 2.1. Hardware... 4 2.2. Software... 5 3. Applications...

More information

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211

E1 and T1 RJ-48 Cable Pinouts on page 208. Fast Ethernet 12-port Cable Pinouts on page 211 Appendix A This chapter contains tables that list the pinouts for the following cable connectors on the router: RJ-45 Connector Pinouts for the Ethernet Management Port on page 207 DB-9 Connector Pinouts

More information

SIOX-RS232C Converter

SIOX-RS232C Converter L40 SIOX-RS232C Converter p 2 TELEFRANG AB TABLE OF CONTENTS SIOX-RS232C Converter General Description This module connects a CRT terminal or other RS232C serially communicating I/O device as a station

More information

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X

EtherSeries. EtherSeries CR-2. CR-2-Opto. User s Guide. Revised October 7, 2013 Firmware Version 1.X EtherSeries EtherSeries CR-2 & CR-2-Opto User s Guide Revised October 7, 2013 Firmware Version 1.X TABLE OF CONTENTS SECTION 1 - DESCRIPTION... 2 SECTION 2 - SPECIFICATIONS... 4 SECTION 3 - INSTALLATION...

More information

Attaching Inputs and Outputs

Attaching Inputs and Outputs Attaching Inputs and Outputs Inputs (sources) and outputs (destinations) attach to the input and output connectors on the rear of each enclosure. Inputs attach to the connectors on the left side of the

More information

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function

Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200 Document Set. Function Appendix A Specifications This appendix lists the specifications for the BANDIT family of products. Note: For BANDIT II, BANDIT III, or VSR-1200 specifications, see the BANDIT II, BANDIT III, and VSR-1200

More information

Multiplexer FMUX / 16E1. 16 E1 Channels. Installation and Operation Manual. Document Version: 2.2E / Cronyx

Multiplexer FMUX / 16E1. 16 E1 Channels. Installation and Operation Manual. Document Version: 2.2E / Cronyx Multiplexer FMUX / 16E1 16 E1 Channels Installation and Operation Manual Document Version: 2.2E / 15.06.2005 Safety Precautions An exclamation point enclosed in a triangle warns the user about important

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014

GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001. Quick Start Guide GFK-2912 October 2014 GE Intelligent Platforms Programmable Control Products PACSystems* RX3i DNP3 Slave Module IC695EDS001 Quick Start Guide GFK-2912 October 2014 g Contents 1. User Features...1 1.1. Overview... 1 1.2. Restart

More information

Cisco ASR 1000 Series Router Specifications

Cisco ASR 1000 Series Router Specifications Cisco ASR 000 Series Router Specifications This appendix provides router specifications and cable assemblies and pinouts for the cables shipped with the Cisco ASR 000 Series Aggregation Services Routers.

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This appendix describes the Catalyst 3550 switch ports and the cables and adapters that you use to connect the switch to other devices. Connector Specifications These sections describe the connectors

More information

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651)

Wrenchman, Inc Old Hwy. # 8 Suite # 122 New Brighton, Minnesota (651) Wrenchman, Inc. 1801 Old Hwy. # 8 Suite # 122 New Brighton, Minnesota 55112 (651) 638-9012 468X Interface Cable Specifications The Interface Cable emulates the Async RS-232 logical interface supported

More information

TVI I300 Hardware Manual Essential Viewing Systems Limited Essential Viewing. TVI I300 Hardware Manual. Page 1

TVI I300 Hardware Manual Essential Viewing Systems Limited Essential Viewing. TVI I300 Hardware Manual. Page 1 Essential Viewing TVI I300 Hardware Manual Page 1 1 OVERVIEW... 3 2 SPECIFICATIONS... 4 3 MECHANICAL DIMENSIONS... 5 4 TVI I300 BOARD CONNECTORS... 6 4.1 CONNECTOR PARTS... 7 4.2 CELLULAR RF ANTENNA J9...

More information

Multiplexer FMUX/SAT. 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode. Installation and Operations Manual

Multiplexer FMUX/SAT. 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode. Installation and Operations Manual Multiplexer FMUX/SAT 4 x E1 ports V.35/RS-530/RS-449 link interface in codirectional mode Installation and Operations Manual Document version: 1.7E / 06.09.2006 FMUX/SAT Multiplexer Safety Precautions

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

Cisco ASR 1001-X Router Specifications

Cisco ASR 1001-X Router Specifications Cisco ASR 00-X Router Specifications This appendix provides the Cisco ASR 00-X Router specifications. Cisco ASR 00 Router Specifications, page Cisco ASR 00 Router Specifications, page Cisco ASR 00 Router,

More information

AUDIO D-Type Pin-outs TALKBOX INSTALLER 12 1U RACK BOX BCD 25/09/07. Broadcast Audio Custom Manufacture Design and Consultancy

AUDIO D-Type Pin-outs TALKBOX INSTALLER 12 1U RACK BOX BCD 25/09/07. Broadcast Audio Custom Manufacture Design and Consultancy AUDIO D-Type Pin-outs TALKBOX DC POWER 4-6V LS DIM VOX LVL CE TALKBOX TALKBOX I/O CONECTIONS MIC LVL Talkbox D5F connector Pins and 4 : Balanced microphone signal. Pins and 5 : Signal ground. Pins and

More information

RM024 DVK USER GUIDE VERSION 1.2

RM024 DVK USER GUIDE VERSION 1.2 USER GUIDE VERSION 1.2 Americas: +1-800-492-2320 Asia: +852-2923-0610 REVISION HISTORY Version Revision Date Change Description Approved By 1.0 20 Dec 2012 Initial Release Chris Downey 1.1 15 Apr 2014

More information

WiFi to RS-232 adapter user manual

WiFi to RS-232 adapter user manual WiFi to RS-232 adapter user manual WiFi to RS-232 adapter Package Contents: WiFi RS-232 adapter x 1 A4 User manual x 1 Mini USB Cable x 1 White Box Dimension: 11 x 6 x 5 (cm) Total Package Weight: 126

More information

DS Series Manual DATA SWITCH. DS62-MD4 Host-Modem Module QUICK START. BayTech Manual Publication

DS Series Manual DATA SWITCH. DS62-MD4 Host-Modem Module QUICK START. BayTech Manual Publication DS Series Manual DATA SWITCH DS62-MD4 Host-Modem Module QUICK START BayTech Manual Publication Revision May 2008 Copyright 2007 by Bay Technical Associates, Inc. BayTech, is a registered trademarks of

More information

AXIS 250S Blade Rack Solution Installation Guide

AXIS 250S Blade Rack Solution Installation Guide AXIS 250S Blade Rack Solution Installation Guide 2 About This Document This document is intended as an addendum to the video server User s Manual. It includes instructions for installing the Axis Rack

More information

RS-232 Connector Pin Assignments

RS-232 Connector Pin Assignments APPENDIXB This appendix lists the connector pin assignments for the CDEs, and includes the following sections: Serial Console-Interface, page B- Ethernet, page B- Cable Pin Assignments, page B- Serial

More information

Interface Technology Group, Inc.

Interface Technology Group, Inc. Interface Technology Group, Inc. Model RDU 1.2X2 Reader Display Unit Operation and Maintenance Manual Firmware Version 2.02 Specifications: Interface Technology Group, Inc. 2107 South Hwy US-1 Rockledge,

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-08-23 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

E Serial Controller

E Serial Controller SmartSet Technical Reference Manual Addendum for the E281-2310 Controller 1 E281-2310 Serial Controller The following figure shows the mounting dimensions, jumper locations, and connections for the IntelliTouch

More information

EasySYNC Ltd. USB to Serial Converters Manual

EasySYNC Ltd. USB to Serial Converters Manual EasySYNC Ltd Document Reference No.: ES_000061 Issue Date: 2011-01-26 The ES-U-xxxx-x adapters are a series of USB Serial Converters from EasySYNC Ltd. They provide a simple method of adapting legacy RS-232

More information

NPort 5100 Series Quick Installation Guide

NPort 5100 Series Quick Installation Guide NPort 5100 Series Quick Installation Guide Edition 4.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Epson PX4 info page. Pinouts and circuit diagrams: RS232 Serial Port Parallel Printer Port Config DIP Switches System Bus Port

Epson PX4 info page. Pinouts and circuit diagrams: RS232 Serial Port Parallel Printer Port Config DIP Switches System Bus Port Epson PX4 info page Epson PX4 info page Pinouts and circuit diagrams: RS232 Serial Port Parallel Printer Port Config DIP Switches System Bus Port Also i have summarised the PX4 manual with this CP/M command

More information

Storage/Control I/O Module

Storage/Control I/O Module CHAPTER 4 The performs two functions: to connect outside interfaces to the system controller and to house the hard disk drive. It plugs into the back of the VCO/4K system and provides the I/O interfaces

More information

SIU-218 and SIU-2218

SIU-218 and SIU-2218 SIU-218 and SIU-2218 Serial Interface Unit THIS MANUAL CONTAINS TECHNICAL INFORMATION FOR THE SIU-218 AND SIU-2218 SERIES SERIAL INTERFACE UNIT REVISION: OCTOBER 2013 pn 888-0218-001 THE SIU-218 AND SIU-2218

More information

UPort 2000 Series User s Manual

UPort 2000 Series User s Manual User s Manual Second Edition, December 2012 www.moxa.com/product 2012 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be

More information

Connector and Cable Specifications

Connector and Cable Specifications APPENDIX B This appendix describes the pinouts and cabling requirements for the interfaces and cables used on the Cisco ubr925 cable access router. All connectors for these interfaces are on the rear-panel,

More information

Cable and Port Specifications

Cable and Port Specifications APPENDIXC This appendix provides cable and port specifications, and includes the following sections: Cables and Adapters Provided, page C-1 Console Port, page C-2 COM1 Port, page C-3 MGMT 10/100/1000 Ethernet

More information

Operation & Installation Manual Serial Receiver Driver Model CP-SRD

Operation & Installation Manual Serial Receiver Driver Model CP-SRD 92 53600 000-11 Operation & Installation Manual Serial Receiver Driver Model CP-SRD 92 53600 000 Table of Contents 1.0 Scope...1 2.0 Introduction...1 3.0 Specifications...1 4.0 Control Commands...2 5.0

More information

P/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS

P/N Operation & Installation Manual Serial Control Transfer Switch Model TM-STS P/N 92 53626 000-11 Operation & Installation Manual Serial Control Transfer Switch Model TM-STS 92 53626 000 Table of Contents 1.0 SCOPE 1 2.0 INTRODUCTION 1 3.0 SPECIFICATIONS 2 4.0 EQUIPMENT DESCRIPTION

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

464K PRELIMINARY 3-STAGE SOLID STATE SWITCH SYSTEMS 464K SALIENT FEATURES SYSTEM OPERATION 464K DESCRIPTION

464K PRELIMINARY 3-STAGE SOLID STATE SWITCH SYSTEMS 464K SALIENT FEATURES SYSTEM OPERATION 464K DESCRIPTION 3-STAGE SOLID STATE SWITCH SYSTEMS PRELIMINARY SALIENT FEATURES SYSTEM OPERATION 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent crosspoints in one mainframe Built-in self

More information

Interface Technology Group, Inc.

Interface Technology Group, Inc. Interface Technology Group, Inc. Model RDU-.56-3 Triple CS-5 Reader Display Unit Operation and Maintenance Manual Interface Technology Group, Inc. 2107 South Hwy US-1 Rockledge, FL 32955 V 321-433-1165

More information

OnCell G3100 Series Quick Installation Guide

OnCell G3100 Series Quick Installation Guide OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

NPort S8000 Series Quick Installation Guide

NPort S8000 Series Quick Installation Guide NPort S8000 Series Quick Installation Guide Edition 6.0, March 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Specification Sheet S2561E-001 Single-Ended Flexible 256x256 Analog Switching Array Building Block to 1024x1024 System S2561E

Specification Sheet S2561E-001 Single-Ended Flexible 256x256 Analog Switching Array Building Block to 1024x1024 System S2561E Specification Sheet S256E-00 Single-Ended Flexible 256x256 Analog Switching Array Building Block to 024x024 System S256E January 2009 Applications Audio, Data or Video routing E audio switching Production

More information

Introduction & Specifications of Hi-Speed USB to Serial Adapters

Introduction & Specifications of Hi-Speed USB to Serial Adapters Introduction & Specifications of Hi-Speed USB to Serial Adapters The USB Serial Adapters consist of the following models: USB Single Serial Adapter (ES-U-1001, ES-U-1001-A) USB Single Serial Adapter (ES-U-1001-M,

More information

NPort 5200 Series Quick Installation Guide

NPort 5200 Series Quick Installation Guide NPort 5200 Series Quick Installation Guide Edition 8.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778

More information

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer

Chapter 11: Input/Output Organisation. Lesson 05: Asynchronous RS232C Serial Port data transfer Chapter 11: Input/Output Organisation Lesson 05: Asynchronous RS232C Serial Port data transfer Objective Understand the RS232C asynchronous data transfer and signals Learn the RS232C serial port communication

More information

Time synchronization for APR64 / APR64M

Time synchronization for APR64 / APR64M 03/21/2013 Edition Time synchronization for APR64 / APR64M dfv Technologie Z.A. Ravennes-les-Francs 2 avenue Henri Poincaré BP 80009 59588 BONDUES CEDEX FRANCE Tel : 33 (0) 3.20.69.02.85 Fax : 33 (0) 3.20.69.02.86

More information

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS

LM058 Bluetooth Serial Adapter SMA Antenna 100m m Range SPP GAP + Wireless DTR DSR RTS CTS LM0 Bluetooth Serial Adapter SMA Antenna Features The can communicate with another Bluetooth serial adapter or Bluetooth devices such as laptops, desktops, PDA s or mobile phones. Supports Bluetooth Serial

More information

RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter

RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter RS-232 / RS-422 / RS-485 over Fast Ethernet Media Converter Serial Interface One RS-232/422/485 port to one 100Base-FX Media Converter Cost-effective solution for RS-232 to Ethernet application Supports

More information

Features and Benefits. Certifications

Features and Benefits. Certifications MPC-2260 Series 26-inch ECDIS color calibrated, fanless panel computers Features and Benefits 26-inch panel computer Color calibrated for ECDIS compliance Third-generation Intel processor (Intel Core i7

More information

PRECISION PROGRAMMABLE

PRECISION PROGRAMMABLE PRECISION PROGRAMMABLE P A T C H SOLID STATE SWITCH SYSTEMS 9 9 SALIENT FEATURES High density,00 cross points in one mainframe Solid state reliability Built-in self test and diagnostics with test subsystem

More information

Features and Benefits. Certifications

Features and Benefits. Certifications MPC-2240 Series 24-inch ECDIS color calibrated, fanless panel computers Features and Benefits 24-inch panel computer Color calibrated for ECDIS compliance Intel Core processor: i7 3517UE 1.7 GHz or Celeron

More information

Starter Guide Version Sphinx Access Control System

Starter Guide Version Sphinx Access Control System TC3XYMT/TC3XYNT Starter Guide Version 1.04.1 Sphinx Access Control System Page 1 1. Controller and Reader wiring...3 2. Connect the controller to PC...4 2.1. Setup the ID of Controller...4 2.2. Connect

More information

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)

EX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an

More information

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00

Message Display Operator Panel. UCT-33/36 Industrial Terminal. Manual 32.00 BRODERSEN Message Displays/Operator Panels Message Display Operator Panel UCT-33/36 Industrial Terminal Manual 32.00 Brodersen Controls A/S. Betonvej 0. DK-4000 Roskilde. Denmark. Tel (+45) 46 74 00 00.

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.

More information

GNS-MC35iT, GNS-MC35iU Terminals datasheet

GNS-MC35iT, GNS-MC35iU Terminals datasheet datasheet 2007 Contents Document history...3 1 Abstracts...4 2 Key features...4 3 Electrical and environmental characteristics...5 4 Operating modes...7 5 Power supply...8 6 Power on/off control...9 7

More information

464kA. 256x256 SOLID STATE SWITCH SYSTEMS. 464kA SALIENT FEATURES SYSTEM OPERATION. 464kA DESCRIPTION

464kA. 256x256 SOLID STATE SWITCH SYSTEMS. 464kA SALIENT FEATURES SYSTEM OPERATION. 464kA DESCRIPTION 256x256 SOLID STATE SWITCH SYSTEMS SALIENT FEATURES 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent cross points in one mainframe Bus frames to form larger systems Built-in

More information

Feature and Benefits. Certifications

Feature and Benefits. Certifications UC-2100 Series Arm-based palm-sized industrial computing platform for IIoT applications Feature and Benefits Armv7 Cortex-A8 1000 MHz processor 1 or 2 auto-sensing 10/100 Mbps Ethernet ports Gigabit Ethernet

More information

General Operating, Maintenance and Installation Manual

General Operating, Maintenance and Installation Manual General Operating, Maintenance and Installation Manual Hardware Platform for Protocol Converter Small Embedded Controller - SEC2-91056 Erlangen Telephone +49 9131 92076-0 Fax: +49 9131 92076-10 Internet:

More information

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A. A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and

More information

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card

EX & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card EX-45362 & EX-45362IS 2S RS232/422/485 3-in-1 Serial PCIe Card Congratulation on your purchasing this high performance 2-Port RS232/422/485 3-in-1 Serial PCIe Host Adapter. The adapter is high speed PCIe

More information

Introducing the Cisco NAM 2220 Appliance

Introducing the Cisco NAM 2220 Appliance CHAPTER 1 This chapter provides an introduction to the Cisco NAM 2220 appliance and describes the appliance hardware, major components, and front- and rear-panel LED indicators, controls, and connectors.

More information

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature Programmable Controllers iopac 8500 Series Award-winning Product Rugged modular RTU controllers Dedicated ARM (RISC) CPUs for the main system and each I/O module Millisecond timestamp granularity for digital

More information

AB300-Series Automated Filter Wheels

AB300-Series Automated Filter Wheels AB300-Series Automated Filter Wheels User Manual 1049478 August 2006 1. Introduction 1.1 Mission Statement Our mission is to provide our customers with reliable products, on time, and at a fair price.

More information

EMERALD-MM-8P. 8-Channel Software Programmable Protocol. Serial Port PC/104 TM Module. User Manual V1.20

EMERALD-MM-8P. 8-Channel Software Programmable Protocol. Serial Port PC/104 TM Module. User Manual V1.20 EMERALD-MM-8P 8-Channel Software Programmable Protocol Serial Port PC/104 TM Module User Manual V1.20 Copyright 2005, 2008, 2011 DIAMOND SYSTEMS CORPORATION 555 Ellis Street Mountain View, CA 94043 Tel

More information

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany

UniMod Ethernet. LAN-Modem. Bär Industrie-Elektronik GmbH Siemensstr. 3 D Fürth Germany LAN-Modem Operation Manual E121711217066 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Germany Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed

Features: Analog to Digital: 12 bit resolution TTL outputs, RS-232 tolerant inputs 4.096V reference (1mV/count) 115K max speed The Multi-I/O expansion board gives users the ability to add analog inputs and outputs, UART capability (for GPS or modem) and isolated high current outputs to the Flashlite 386Ex. Available in several

More information

VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99

VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99 VS-626M5 Parameter Upload/Download Software User s Manual (Preliminary) 5/18/99 Computer Requirements The following hardware and software are required to run the M5 Parameter Upload/Download software.

More information

Universal Asynchronous Receiver Transmitter Communication

Universal Asynchronous Receiver Transmitter Communication Universal Asynchronous Receiver Transmitter Communication 13 October 2011 Synchronous Serial Standard SPI I 2 C Asynchronous Serial Standard UART Asynchronous Resynchronization Asynchronous Data Transmission

More information

Saturn Reader User Manual

Saturn Reader User Manual FCC Compliance Saturn Reader User Manual Version 1.00 On Track Innovations Ltd. (O T I) P/N 1100054F P/N 1100054F page 0 FCC Compliance FCC Compliance This device (Reader Saturn 3000) complies with Part

More information

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter ICD105A 1008 page 1/5 7319 r001 ICD105A Industrial RS-232 to RS-422/485 Converter Data Rates up to 115.2 Kbps 10 48 VDC Input Power Range Wide Operating Temperature 3-Way 2000V Optical Isolation Modbus

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter

Industrial PC IPC191V2. General Operating, Maintenance and Installation Manual. Hardware Platform Protocol Converter Industrial PC IPC191V2 General Operating, Maintenance and Installation Manual Hardware Platform Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de

More information

Industrial Serial Device Server

Industrial Serial Device Server 1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device

More information

RHODEUS PANEL I/O BOARD

RHODEUS PANEL I/O BOARD RHODEUS PANEL I/O BOARD User Manual Revision A April 2011 Revision Date Comment A 4/11/11 Initial Release FOR TECHNICAL SUPPORT PLEASE CONTACT: Copyright 2011 Diamond Systems Corporation 555 Ellis Street

More information

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-E1E Managed E1 and Fractional E1 Access Device FCD-E1E E1 main link and sublink supporting both framed and unframed signals One data port with selectable sync data rates of n 64 kbps Optional sub-e1 drop-and-insert port Optional Ethernet 10/100BaseT

More information

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO

F8016. Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO F8016 Fiber Modem for up to 4E1 /8E1/12E1/16E1 + RS232+Ethernet+ optional V.35/QFXS/QFXO Description The fiber transmission platform is a fiber optic multiplexer with a fully new designing concept to challenge

More information

1:N REDUNDANT SWITCHING UNIT BROADBAND SERIES

1:N REDUNDANT SWITCHING UNIT BROADBAND SERIES MITEQ TECHNICAL NOTE 25T030 OCTOBER 1999 REV D 1.1 GENERAL DESCRIPTION 1.1.1 PHYSICAL 1:N REDUNDANT SWITCHING UNIT BROADBAND SERIES SECTION 1 INTRODUCTION Figure 1-1. Front Panel, 1:N Redundant Switching

More information

ALIANT OMMUNICATIONS. VCL-MegaConnect-Jr. 16 Port E1/T1 Mixed Configuration DACS and Interface Converter

ALIANT OMMUNICATIONS. VCL-MegaConnect-Jr. 16 Port E1/T1 Mixed Configuration DACS and Interface Converter V C ALIANT OMMUNICATIONS VCL-MegaConnect-Jr. 16 Port E1/T1 Mixed Configuration DACS and Interface Converter Product Brochure & Data Sheet U.K. Valiant Communications (UK) Ltd 1, Acton Hill Mews, 310-328

More information

464kB SOLID STATE SWITCH SYSTEMS. 464kB SALIENT FEATURES SYSTEM OPERATION. 464kB DESCRIPTION

464kB SOLID STATE SWITCH SYSTEMS. 464kB SALIENT FEATURES SYSTEM OPERATION. 464kB DESCRIPTION SOLID STATE SWITCH SYSTEMS SALIENT FEATURES 3-stage non-blocking solid state switch matrix High density: 65,536 equivalent cross points in one mainframe sizes to meet unique requirement:, 224 x 224, 192

More information

Market Central

Market Central SwitchMaster XK5000 Series Ultra-Compact Kill Switch System OCT 2012 Part Numbers Market Central www.secureswitch.com 500 Business Center Drive Pittsburgh, PA 15205 USA 412.494.2800 CAGE 1BGJ7 COMPLETE

More information

Vorne Industries. 87/708 Master Clock Display User's Manual

Vorne Industries. 87/708 Master Clock Display User's Manual Vorne Industries 87/708 Master Clock Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 www.vorne.com Chapter 1 Setting Up Your Display For Operation...

More information

MX ASI-IP & MX IP-ASI

MX ASI-IP & MX IP-ASI User s Manual MX ASI-IP & MX IP-ASI DVB-ASI Over Ethernet Network Adapters Installation and User Guide T A B L E O F C O N T E N T S MX ASI-IP Network Adapter... 2 Command Line Description... 4 MX IP-ASI

More information