1 Operation Manual Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

2 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION WATER PROOF INSTALLING THE BATTERIES DISPLAY & KEYS FUNCTIONS A. Display...4 B. Keys...5 MODES OF THE METER OPERATIONAL PROCEDURES A. Preparing Standard Solutions...8 B. Calibration...8 C. Conductivity Measurements...10 D. Save, Recall and Delete Data...10 ERROR DISPLAYS AND TROUBLESHOOTING...12 SPECIFICATIONS WARRANTY

3 GENERAL INTRODUCTION Thank you for selecting the 3010M meter. The 3010M is a precision tool that measure conductivity, salinity, TDS and temperature. A built-in microprocessor stores, calculates and compensates for all parameters related to conductivity and temperature determinations. This unit has a waterproof IP65 case. The touch mode keys are highly reliable with tactile and audio feedback. This meter can operate with one 9V battery. Re-calibration is not required when power is restored. The front of the meter has a large LCD that displays temperature and either temperature compensated or non-temperature compensated conductivity, salinity or TDS simultaneously along with user prompts and mode indicators. The unit prompts the user through calibration and measurement procedures. The unit is also equipped with a non-volatile memory allowing the user to store 50 different sets of readings. This unit will assign a site number for each set of reading so the user can review the data easily. The model 3010M is available with three two-wire conductivity cell (K=0.1; 1.0; 10.0). Other features include automatic conductivity ranging, automatic temperature compensation, long battery life, and 50/60 Hz AC noise rejection. This unit is universal and user-friendly for field, industrial and laboratory applications. INITIAL INSPECTION Carefully unpack the unit and accessories. Inspect for damages made in shipment. If any damage is found, notify your Jenco representative immediately. All packing materials should be saved until satisfactory operation is confirmed. WATER PROOF Though the 3010M meter is housed in a watertight case, DO NOT use it underwater. The watertight case prevents permanent damage to the unit if accidentally dropped into non-corrosive solutions. Follow these steps immediately if the unit is immersed in any solution: 1. Rinse unit carefully with distilled water. After rinsing and drying, inspect and clean connectors to remove all contaminants that may affect probe connections. 2

4 2. Wait for the unit and probe to dry completely before resuming operation. 3. If the unit does not function correctly after steps1 and 2, call JENCO for possible repair or replacement (see Warranty). INSTALLING THE BATTERIES The 3010M meter is packaged with one 9V battery required for operation. To insert the batteries into the meter, follow the procedure outlined below. Figure 1: Battery compartment 1. Use a screw driver to remove the two screws and battery cover to expose the battery compartment. (Figure 1.) 2. Note the polarity and insert the batteries into the battery compartment correctly. 3. Replace the battery cover and make sure to secure the two screws for the water-tight feature. [Note: Press the ON/OFF key to turn the unit on. If the unit is running then you can press the ON/OFF key to turn the unit off. The unit will automatically turn off after 30 minutes of no key activity.] 3

5 DISPLAY & KEYS FUNCTIONS A. Display Figure 2: Active LCD screen BAT- Low battery indicator. 2. Full- This will indicate that all 50 data storage sites are used up. 3. CELL- Indicates conductivity cell constant value. 4. TDS- Displays when measuring total dissolved solids. 5. SALINITY- Displays when measuring salinity. 6. CAL- Calibration mode indicator 7. All- To delete all the data in the data storage. 8. Delete- To delete stored data. 9. Each- To delete a single set of data from the data storage. 10. /%- Displays during calibration: : Indicates temperature reference unit. % : Indicates temperature coefficient unit. 11. ppt- Parts per thousand for salinity measurement. 12. MAIN DISPLAY- For compensated and uncompensated conductivity, salinity and TDS values. 13. us/msmicrosiemens or millisiemens for conductivity measurement. 14. mg/l- Grams/Liter for TDS measurement. 4

6 15. Temperature and unit display 16. Data storage site number. 17. Save- To save a reading into the data storage. 18. CONDUCTIVITY- Displays when measuring conductivity. 19. Recall- To recall data from the data storage. 20. UNCOMPENSATED- Distinguish between temperature compensated and non-temperature compensated reading. B. Keys ON/OFF- Powers on and shuts off the meter. MODE- Selects display mode. In normal operation, press this key to sequentially display compensated conductivity, salinity, total dissolved solids (TDS), uncompensated conductivity, Recall and Delete interface. In calibration mode, press this key to exit the current calibration parameter and enter into the next one. In Recall and Delete modes, press this key to exit Recall and Delete modes respectively. UP/DOWN- Increases or decreases the display value as desired. In Recall mode, view saved data and data storage site number by pressing these keys. In Delete mode, press these keys to select between the Delete Each and Delete All mode. In Delete Each mode, view to be deleted data and data site numbers by pressing these keys. CAL- In Measurement mode, press this key to enter into Calibration mode. 5

7 ENTER- In Calibration mode, press this key to save the current parameter to memory. In Measurement mode, press this key to save reading into the next available data storage site. At the Recall interface, press this key to display the last set of saved data. At the Delete interface, press this key to go into Delete mode. In the Delete All mode, press this key to delete all saved data. In the Delete Each mode, press this key to delete a single set of data. MODES OF THE METER 1. UNCOMPENSATED mode: The unit will display non-temperature compensated conductivity reading. 2. COMPENSATED mode: The unit will display temperature compensated conductivity reading. 3. TDS mode: The unit will display TDS reading. 6

8 4. SALINITY mode: The unit will display SALINITY reading. 5. Recall interface: Press ENTER key to go into recall mode. 6. Recall mode: In this mode, user can recall data saved in memory. 7. Delete interface: Press ENTER key to go into delete mode. 8. Delete mode: In this mode, user can erase each data or all data saved in memory. 7

9 OPERATIONAL PROCEDURES A. Preparing Standard Solutions Suitable conductivity standards are available commercially or the user can prepare them using research grade reagents. Here are some standard solutions the user can prepare to calibrate the probe of the model 3010M. 1. Standard solution of 1413uS at 25 : Accurately weight out grams of research grade dried Potassium Chloride (KCL). Dissolve in 1000ml of distilled water. 2. Standard solution of 12.90mS at 25 : Accurately weight out grams of research grade dried Potassium Chloride (KCL). Dissolve in 1000ml of distilled water. 3. Standard solution of 111.9mS at 25 : Accurately weight out grams of research grade dried Potassium Chloride (KCL). Dissolve in 1000ml of distilled water. 4. Standard solution of 147uS at 25 : Accurately measure out 100ml of the 1413uS standard solution as in point 1. Dilute it with 900ml of distilled water. 5. Standard solution of 14.94uS at 25 : Accurately measure out 100ml of the 147uS standard solution as in point 4. Dilute it with 900ml of distilled water. [Note: The user can store the remaining solution in a plastic container for one week but the air space between the cap and the solution must be kept to an absolute minimum. Storing the excess solution below 4 can increase the storage life. If you have any doubt of the accuracy of the stored solution, a fresh batch should be prepared.] B. Calibration Calibration setup contains five parameters: TDS, Cell, Temperature Coefficient, Temperature reference and Conductivity Calibration. To access these sections: 1. Connect the conductivity probe either the 109A (K=0.1) or the 106A (K=1.0) or the 107A (K=10.0) to the unit and turn the unit on. The screen will display the CELL icon and the cell constant of the previous calibration. (Factory default is set at K=1.0). 8

10 2. Allow temperature reading to stabilize, press CAL key to enter the calibration mode. The CAL icon appears on the LCD. Press MODE key to sequentially view previous calibration settings. TDS TDS is determined by multiplying conductivity (ms) by a TDS factor. The default factor value is To change the TDS factor, use the UP and DOWN keys to adjust the value between 0.30 and Press ENTER key to save the new value and the unit will automatically go into the next calibration parameter. If MODE key is pressed instead of the ENTER key, any changes made will be cancelled and the previous calibration settings will be retained. CELL Use UP and DOWN keys to select cell constant between C0.1 or C1.0 or C10.0 on the secondary display. Press ENTER key to confirm selection and the unit will then automatically go into the next calibration parameter. If MODE key is pressed instead of the ENTER key, any changes made will be cancelled and the previous calibration settings will be retained. Temperature Coefficient The unit uses the temperature coefficient to calculate temperature compensated conductivity. The default value is 1.91%. To change the temperature coefficient, use the UP and DOWN keys to adjust the value between 0 and 4.00%. Press ENTER key to save the new value and the unit will automatically go into the next calibration parameter. If MODE key is pressed instead of the ENTER key, any changes made will be cancelled and the previous calibration settings will be retained. Temperature Reference The unit uses the temperature reference value to calculate temperature compensated conductivity. The default value is 25. To change the temperature coefficient, use the UP and DOWN keys to adjust the value between 15 and 25. Press ENTER key to save the new value and the unit will automatically go into the next calibration parameter. If MODE key is pressed instead of the ENTER key, any changes made will be cancelled and the previous calibration 9

11 settings will be retained. Conductivity Calibration (a) Immerse the probe in a standard of known conductivity, preferably a standard in the middle range of the solutions to be measured. Immerse the probe (at least 2 to 3 or 5~7cm from the tip) into standard solution without touching the sides of the calibration container. Shake the probe lightly to remove any air bubbles trapped in the conductivity cell. (b) Allow temperature to stabilize. The message rage (range) may appear briefly on the display indicating auto-ranging; this is normal. After temperature stabilization, use the UP and DOWN keys to adjust the conductivity value to that of the conductivity standard at 25. Press ENTER key to calibrate. The unit beeps to indicate a successful calibration. Calibration is now complete and the unit will automatically switch to Measurement mode. C. Conductivity Measurements 1. Turn the unit on. Place the probe in the solution to be measured. Immerse the probe (at least 2 to 3 or 5~7cm from the tip) in the sample solution. Shake the probe lightly to remove any trapped air bubbles in the conductivity cell. 2. Press MODE key to enter into the desired measurement mode. The message rage (range) may appear briefly on the display indicating auto-ranging; this is normal. Allow temperature to stabilize. D. Save, Recall and Delete Data a. Saving readings to memory. 1. In compensated conductivity, salinity, total dissolved solids (TDS) and uncompensated conductivity modes, press the ENTER key to save data. The Save icon with the corresponding site number will lit up for a brief moment to indicate a successful data save. 2. If the Full icon is displayed, this means that all 50 data saving sites are used up. No new data can be saved until existing saved data are deleted. 10

12 b. Recalling readings from memory. 1. To recall saved data, press ENTER key at the Recall interface to go into Recall mode. 2. Press the UP or DOWN keys to select the storage site number. 3. Press MODE key to exit Recall mode. c. Deleting data. 1. Press the ENTER key at the Delete interface to go into Delete mode. 2. Select Delete All or Delete Each mode by pressing the UP or DOWN key. 3. In the Delete all mode, press ENTER key to clear all stored data. Deletion is now complete. 4. In the Delete Each mode, use UP and DOWN key to select data to be deleted. Then press ENTER key to delete. Deletion is now complete. The next set of saved data will automatically move up a slot in the storage site. 5. Press MODE key to exit Delete mode. 11

13 ERROR DISPLAYS AND TROUBLESHOOTING Main Display "OvEr" during measurements Secondary Display / Possible Cause(s) Conductivity is > 400.0mS (K=10.0). Conductivity is > 40.0mS (K=1.0) Corrective Action(s) Ensure the probe is immersed at least 2 ~3 or 5~7cm from the tip, below the surface of the sample/standard solution. Conductivity is > 400.0uS (K=0.1) Allow sufficient time for the electrode and Temp probe to stabilize. "OvEr " during calibration / Cell Constant Calibration is out of range. Recalibrate with correct value for the conductivity standard. Replace conductivity standard. Clean cell. "OvEr " during measurements ovr udr Temperature > 90.0 Temperature < Decrease/Increase the sample temperature. [Note: If the unit still does not perform normally after the above measures are taken, call Jenco Service Department.] 12

14 SPECIFICATIONS Display Range Resolution Accuracy Conductivity K=0.1 Conductivity K=1.0 Conductivity K= ~9.999uS/cm; 10.0~99.99uS/cm; 100.0~400.0uS/cm 0.00~99.99uS/cm; 100.0~999.9uS/cm; 1000~9999uS/cm 10.00~40.00mS/cm 0.001uS/cm 0.01uS/cm 0.1uS/cm 0.01uS/cm 0.1uS/cm 1uS/cm 0.01mS/cm 0.0~999.9uS/cm; 0.1uS/cm 1000~9999uS/cm; 1uS/cm 10.00~99.99mS/cm; 0.01mS/cm 100.0~400.0mS/cm 0.1mS/cm ±0.5% Full Scale ±0.5% Full Scale ±0.5% Full Scale Salinity 0.0 to 70.0ppt 0.1ppt ±0.2% Full Scale Temperature to 90.0 C 0.1 C ±0.2 C or ±0.4% Full Scale, whichever is greater. Reference Temperature 15.0 to 25.0 C Temperature Coefficient 0.0% to 4.0% Cell Constant Two-wire cell: K=0.1; 1.0; 10.0 TDS Constant Range 0.30 to 1.00 Power Calibration Back-up Datalogging capabilities Automatic shut off function Audio Feedback Display(Conductivity/ Salinity /TDS/mV : Temp) Ambient Temperature Range Relative Humidity Case Dimensions (W x D x H) Weight 9Volt battery EEPROM 50 data sets 30 minutes of non-use All Touch Keys 12mm : 8mm high LCD 0 to 50 C At 90% RH IP65 waterproof 70mm x 198mm x 37mm 260 grams (Batteries included) 13

15 WARRANTY Jenco warrants this product to be free from significant deviations in material and workmanship for a period of 1 year from date of purchase. If repair or adjustment is necessary and has not been the result of abuse or misuse, within the year period, please return-freight-prepaid and the correction of the defect will be made free of charge. If you purchased the item from our Jenco distributors and it is under warranty, please contact them to notify us of the situation. Jenco Service Department alone will determine if the product problem is due to deviations or customer misuse. Out-of-warranty products will be repaired on a charge basis. RETURN OF ITEMS Authorization must be obtained from one of our representatives before returning items for any reason. When applying for authorization, have the model and serial number handy, including data regarding the reason for return. For your protection, items must be carefully packed to prevent damage in shipment and insured against possible damage or loss. Jenco will not be responsible for damage resulting from careless or insufficient packing. A fee will be charged on all authorized returns. NOTE: Jenco reserves the right to make improvements in design, construction and appearance of our products without notice. 14

16 Jenco Instruments, Inc Arjons Drive, Suite C San Diego, CA USA TEL: FAX: jencoinfo@jencoi.com; sales@jencoi.com Website: Jenco Electronics Inc. 1F., NO. 11, Lane 370, Sec. 6, Zhongxiao E. Rd. Nangang Dist., Taipei, Taiwan TEL: FAX: Shanghai Jenco Instruments, Ltd. 18 Wang Dong Zhong Road Sijing Town, Songjiang Shanghai, China TEL: FAX: jencos@jenco.com.cn Website: 15

17 16

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

Operation Manual. Hand-held ph/orp/temperature Meter 6010M Operation Manual Hand-held ph/orp/temperature Meter 6010M CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......3 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS FUNCTIONS..... 4

More information

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80 Operation Manual MODEL ph/ec80 Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter ph/ec80 CONTENTS INITIAL INSPECTION AND ASSEMBLY...2 BEFORE YOUR FIRST USE......2 A. Replace the

More information

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter

Operation Manual. MODEL ph6175. Microcomputer Based ph/orp/temperature Benchtop Meter Operation Manual MODEL ph6175 Microcomputer Based ph/orp/temperature Benchtop Meter ph6175 0 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 POWER INPUT.......2 INSTALLING THE BATTERIES.....3

More information

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R

Operation Manual MODEL 3173/3173R. MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R Operation Manual MODEL 3173/3173R MICROCOMPUTER BASED Conductivity/Salinity/TDS &Temperature BENCH METER 3173/3173R INITIAL INSPECTION..... 2 GENERAL INTRODUCTION.. 2 USING THE METER. 3 THE DISPLAY....

More information

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810 Operation Manual Hand-held ph/mv/temperature Meter ph6810 CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS FUNCTIONS..... 4

More information

Operation Manual. MODEL ph 630. Microcomputer Based ph&temperature Pocket Meter. ph630

Operation Manual. MODEL ph 630. Microcomputer Based ph&temperature Pocket Meter. ph630 Operation Manual MODEL ph 630 Microcomputer Based ph&temperature Pocket Meter ph630 CONTENTS INITIAL INSPECTION AND ASSEMBLY...2 BEFORE YOUR FIRST USE... 2 A. Replace the Batteries...2 B. Soak the Electrode......2

More information

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS OPERATION MANUAL JENCO MODEL 6230M/6230N/6231M/6231N MICROCOMPUTER BASED ph/mv/temp PORTABLE METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS Model 6230M 6230N 6231M 6231N Storage Yes

More information

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS OPERATION MANUAL JENCO MODEL 6307 MICROCOMPUTER BASED ph/conductivity/ Salinity/Temperature BENCH METER JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS INITIAL INSPECTION Carefully unpack

More information

Operation Manual MODEL 3621 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Controller MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual MODEL 3621 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Controller MANUFACTURER OF PRECISION INSTRUMENTS Operation Manual MODEL 3621 Microcomputer Based ph/orp Controller JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS CONTENTS GENERALINTRODUCTION)))))))))))))))..)))...2 INITIALINSPECTION))...))))))...2

More information

Operations Manual EcoSense ph100a

Operations Manual EcoSense ph100a Operations Manual EcoSense ph100a Portable ph, mv and Temperature Instrument English CONTENTS GENERAL INTRODUCTION... 3 INITIAL INSPECTION... 3 THE INSTRUMENT... 3 BATTERY INSTALLATION... 3 Battery Disposal...

More information

Operations Manual EcoSense ph100

Operations Manual EcoSense ph100 Operations Manual EcoSense ph100 Portable ph, mv and Temperature Instrument English Français Español Deutsch Italiano WARRANTY The EcoSense ph100 Instrument is warranted for one year from date of purchase

More information

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller Operation Manual CX10 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3

More information

User Manual DOCUMENT #606042REF. EcoSense EC300A EcoSense EC300M Portable Conductivity, Salinity and Temperature Instruments. USER MANUAL English

User Manual DOCUMENT #606042REF. EcoSense EC300A EcoSense EC300M Portable Conductivity, Salinity and Temperature Instruments. USER MANUAL English User Manual DOCUMENT #606042REF EcoSense EC300A EcoSense EC300M Portable Conductivity, Salinity and Temperature Instruments USER MANUAL English WARRANTY The EcoSense EC300A/EC300M Instrument is warranted

More information

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller

Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller Operation Manual CX20 1/8 DIN Microcomputer Based Conductivity/Resistivity Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3

More information

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English User Manual DOCUMENT #601119REF EcoSense ph1000a ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL English Item #601119REF Rev C, October 2017 For the latest version of this manual, visit ysi.com

More information

Operation Manual MODEL 3631 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Transmitter MANUFACTURER OF PRECISION INSTRUMENTS

Operation Manual MODEL 3631 JENCO ELECTRONICS, LTD. Microcomputer Based ph/orp Transmitter MANUFACTURER OF PRECISION INSTRUMENTS Operation Manual MODEL 3631 Microcomputer Based ph/orp Transmitter JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS CONTENTS GENERAL INTRODUCTION(((((((((((((((..(((...2 INITIAL INSPECTION((...((((((...2

More information

Large Display Salinity & Conductivity Pens &

Large Display Salinity & Conductivity Pens & Large Display Salinity & Conductivity Pens 850036 & 850037 Large Display Salinity & Conductivity Pens 850036 & 850037 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents

More information

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller

Operation Manual TX10 1/8 DIN Microcomputer Based ph/orp Controller Operation Manual TX10 1/8 DIN Microcomputer Based /ORP Controller 11751 Markon Drive Garden Grove, CA. 92841 U.S.A. pg. 1 CONTENTS GENERAL INTRODUCTION.....3 INITIAL INSPECTION......3 USING THE Sensorex

More information

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS Operation Manual MODEL 6312PTB ph/temperature Controller JENCO ELECTRONICS, LTD. MANUFACTURER OF PRECISION INSTRUMENTS CONTENTS Page I. INITIAL INSPECTION AND ASSEMBLY 2 II. GENERAL INTRODUCTION 3 III.

More information

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE

More information

DO Meter Kit. Instruction Manual

DO Meter Kit. Instruction Manual DO Meter Kit 850048 Instruction Manual DO Meter Kit 850048 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in any

More information

Datalogging Conductivity/ TDS Meter. Instruction Manual

Datalogging Conductivity/ TDS Meter. Instruction Manual Datalogging Conductivity/ TDS Meter 850039 Instruction Manual 1 TABLE OF CONTENTS 1. INTRODUCTION...3 2. PANEL DESCRIPTION...4 3. MEASURING PROCEDURE...5 3-A General Measurement...5 3-B Auto and Manual

More information

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter 1 Introduction Thank you for selecting the DDS-12DW benchtop conductivity meter.

More information

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8 15,0,15,0,1,14,1,14,13,2,13,2,3,12,3,12,11,4,11,4,5,10,5,10,9,6,9,6,7,8,7,8 WalkLAB Professional Conductivity-TDS-Salinity Meter HC 9021 Operations Manual 0 INTRODUCTION

More information

Cole-Parmer Instrument Company

Cole-Parmer Instrument Company Operating Instructions Cole-Parmer ph/orp 400 ph/orp Controller Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:

More information

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT Pool Professional s Meter TRACER EC/TDS/SAL POCKETESTER TM CODE 1749-KIT TABLE OF CONTENTS Introduction... 4 Specifications... 4 Contents... 5 Parts &

More information

Operation Manual. MODEL ph 618N. Microcomputer Based ph & Temperature Pocket Meter. ph618n

Operation Manual. MODEL ph 618N. Microcomputer Based ph & Temperature Pocket Meter. ph618n Operation Manual MODEL ph 618N Microcomputer Based ph & Temperature Pocket Meter ph618n CONTENTS INITIAL INSPECTION AND ASSEMBLY... 2 BEFORE YOUR FIRST USE...... 2 A. Replace the Batteries... 2 B. Soak

More information

WalkLAB ph mv/orptemperature

WalkLAB ph mv/orptemperature 16,1,16,1,2,15,2,15,14,3,14,3,4,13,4,13,12,5,12,5,6,11,6,11,10,7,10,7,8,9,8,9 WalkLAB ph mv/orptemperature meter HP9000 Operations Manual TABLE OF CONTENTS PAGE 1. INTRODUCTION 1 1.1 Features 1 1.2 Technical

More information

ph, mv and Temperature Instrument

ph, mv and Temperature Instrument User Manual DOCUMENT #606030REF EcoSense ph100a EcoSense ph100m ph, mv and Temperature Instrument USER MANUAL English WARRANTY The EcoSense ph100a/ph100m Instrument is warranted for one year from date

More information

Cole-Parmer Instrument Company

Cole-Parmer Instrument Company Operating Instructions Cole-Parmer ph/orp 350 ph/orp Transmitter Cole-Parmer Instrument Company 625 East Bunker Court, Vernon Hills, Illinois 60061 Tel: 1-847-549-7600 or Toll-free: 1-800-323-4340 Fax:

More information

OPERATION MANUAL MODEL TT-LP

OPERATION MANUAL MODEL TT-LP TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors

More information

Dissolved Oxygen Meter Kit DOK. Instruction Manual

Dissolved Oxygen Meter Kit DOK. Instruction Manual Dissolved Oxygen Meter Kit 850081DOK Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax: 0-3844-6200 Email:

More information

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER

Manual No Revision MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER Manual No. 9835 Revision 0-401 MODEL GLI-9835 HAND-HELD/PORTABLE CONDUCTIVITY/TDS METER Please read this instruction manual carefully before using the instrument. This manual will provide you with all

More information

C100 Handheld Cond./TDS/Sal. Meter. Instruction Manual

C100 Handheld Cond./TDS/Sal. Meter. Instruction Manual C100 Handheld Cond./TDS/Sal. Meter Instruction Manual Table of Contents 1. Introduction ---------------------------------------------------------------------------------------------------------------------------

More information

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Water Quality Meter. Water Quality Meter Kit. Instruction Manual Water Quality Meter 850081 Water Quality Meter Kit 850086 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117, Fax:

More information

MODEL 470 PORTABLE CONDUCTIVITY/TDS METER OPERATING MANUAL CONTENTS

MODEL 470 PORTABLE CONDUCTIVITY/TDS METER OPERATING MANUAL CONTENTS MODEL 470 PORTABLE CONDUCTIVITY/TDS METER OPERATING MANUAL MANUEL D UTILISATION BETRIEBSHANDBUCH MANUALE OPERATIVO MANUAL DE OPERAÇÂO MANUAL DE FUNCIONAMIENTO 470 250/REV A/09-00 MODEL 470 PORTABLE CONDUCTIVITY/TDS

More information

A150 Benchtop Conductivity Meter Instruction Manual

A150 Benchtop Conductivity Meter Instruction Manual A150 Benchtop Conductivity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD A150 Benchtop Conductivity Meter 1 Introduction Thank you for selecting the A150 benchtop conductivity meter. This manual

More information

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications. Instruction Manual HI 9033 HI 9034 Waterproof Multi-Range EC and TDS Meters for Field Applications www.hannainst.com PRELIMINARY EXAMINATION Dear Customer, Thank you for choosing a HANNA instruments product.

More information

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP

User Guide. ExStik TM Model RE300 Waterproof ORP Meter. Patent Pending RE300 ORP 0 User Guide ExStik TM Model RE300 Waterproof ORP Meter Patent Pending 500 MV 1000 TM RE300 ORP ExStik TM Description Front Panel Controls 1. Battery compartment cap 2. LCD Display 3. MODE button 4. CAL

More information

Oyster Meter ph-conductivity-tds-salinity-orp(mv)

Oyster Meter ph-conductivity-tds-salinity-orp(mv) User's Guide Oyster Meter ph-conductivity-tds-salinity-orp(mv) Model 341350A INTRODUCTION Congratulations on your purchase of the Extech's Oyster Series meter. This device measures ph, Conductivity, TDS,

More information

EC/TDS/SAL TRACERTM POCKETESTER CODE Conductivity/TDS/Salinity/Temperature/Meter

EC/TDS/SAL TRACERTM POCKETESTER CODE Conductivity/TDS/Salinity/Temperature/Meter EC/TDS/SAL TRACERTM POCKETESTER CODE 1749 Conductivity/TDS/Salinity/Temperature/Meter WARNING! This set contains chemicals that may be harmful if misused. Read cautions on individual containers carefully.

More information

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170 USER GUIDE Salinity Meter Pen Style Water Quality Meter Model EC170 Introduction Congratulations on your purchase of the Extech Pen Style Water Quality instrument; the Model EC170 measures Salinity and

More information

Datalogging ph Meter

Datalogging ph Meter Specifications Range Resolution Accuracy ph 0.00 ~ 14.00 ph 0.01 ph ±0.02 ph mv -999.9 ~ 999.9mV 0.1 mv ±0.2 mv @ -99.9 ~ 99.9mV ±2 mv @ other ranges Temperature -23 ~ 176 F (-5 ~ 80 C) 0.1 F( 0.1 C) Compensation

More information

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements www.adwainstruments.com Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting

More information

HI HI N HI HI

HI HI N HI HI Instruction Manual HI 935005 - HI 935005N HI 935002 - HI 935009 Portable K-Thermocouple Thermometers w w w. h a n n a i n s t. c o m Dear Customer, Thank you for choosing a Hanna product. Please read this

More information

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD User's Guide ExStik EC400 Conductivity / TDS / Salinity / Temperature Meter MODE HOLD Introduction Congratulations on your purchase of the ExStik EC400 Conductivity/Total Dissolved Solids (TDS) / Salinity

More information

Introduction: Features:

Introduction: Features: Index Features:... 3 Specifications:... 4 Accessories:... 5 Functions of Keyboard:... 7 Preparation:... 8 ... 8 ... 8 Calibration:... 8 ... 8 ... 9 ...

More information

Portable Conductivity Meter M1410. User Manual 1.002

Portable Conductivity Meter M1410. User Manual 1.002 Portable Conductivity Meter M1410 User Manual 1.002 General information This manual describes the operation of the Portable Conductivity Meter M1410. Please read this entire manual before operating this

More information

Tracer TM Salt/EC/TDS PockeTester Code 1749

Tracer TM Salt/EC/TDS PockeTester Code 1749 Tracer TM Salt/EC/TDS PockeTester Code 1749 Pool Professional's Meter! 2 WARNING! This set contains chemicals that may be harmful if misued. Read cautions on individual containers carefully. Not to be

More information

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter User Guide ExStik II EC400 Conductivity / TDS / Salinity / Temperature Meter Introduction Congratulations on your purchase of the ExStik II EC400 Conductivity/Total Dissolved Solids (TDS) / Salinity /

More information

MODEL 470 PORTABLE CONDUCTIVITY/TDS METER OPERATING MANUAL

MODEL 470 PORTABLE CONDUCTIVITY/TDS METER OPERATING MANUAL MODEL 470 PORTABLE CONDUCTIVITY/TDS METER OPERATING MANUAL 470 350/REV A/10-03 MODEL 470 PORTABLE CONDUCTIVITY/TDS METER OPERATING MANUAL CONTENTS Introduction 1 Specification 1-2 Installation 2 Displays

More information

OPERATION MANUAL. JENCO MODEL 6312 CTB MICROCOMPUTER BASED Conductivity/TDS & Temperature TRANSMITTER & CONTROLLER

OPERATION MANUAL. JENCO MODEL 6312 CTB MICROCOMPUTER BASED Conductivity/TDS & Temperature TRANSMITTER & CONTROLLER OPERATION MANUAL JENCO MODEL 6312 CTB MICROCOMPUTER BASED Conductivity/TDS & Temperature TRANSMITTER & CONTROLLER JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD. 7968 ARJONS DR., SUITE C P.O. BOX LINKOU-117

More information

24-hour Continuous Field Monitors

24-hour Continuous Field Monitors Instruction Manual 24-hour Continuous Field Monitors ph, ORP, and Conductivity Technology Made Easy... 68X254901 Rev. 5 08/03 Preface This manual serves to explain the use for all models of the Field Monitors

More information

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual

Colorado Series. CR-10 Portable ph / mv / Temperature Meter Operation Manual Colorado Series CR-10 Portable ph / mv / Temperature Meter Operation Manual 2 Contents Page General Introduction and Initial Inspection.............................. 4 Safety Infomation..................................................

More information

Tracer ph/tds/salt PockeTester TM Code 1766

Tracer ph/tds/salt PockeTester TM Code 1766 Tracer ph/tds/salt PockeTester TM Code 1766 Do Not allow ph sensor to dry out. Store Upright Before first use, tap meter against palm to move electrolyte to tip. See pages 10 and 19. ph/conductivity/tds/salinity

More information

Professional Benchtop Conductivity meter BC3020

Professional Benchtop Conductivity meter BC3020 15,0,15,0,1,14,1,14,13,2,13,2,3,12,3,12,11,4,11,4,5,10,5,10,9,6,9,6,7,8,7,8 Professional Benchtop Conductivity meter BC3020 Operation Manual 0 INTRODUCTION Your purchase of this professional benchtop Conductivity

More information

HI HI N HI HI

HI HI N HI HI Instruction Manual HI 935005 - HI 935005N HI 935002 - HI 935009 Portable K-Thermocouple Thermometers www.hannainst.com These Instruments are in Compliance with the CE Directives Dear Customer, Thank you

More information

JENCO ELECTRONICS,LTD. MANUFACTURER OF PRECISION INSTRUMENTS

JENCO ELECTRONICS,LTD. MANUFACTURER OF PRECISION INSTRUMENTS OPERATION MANUAL JENCO MODEL 6309 POT MICROCOMPUTER BASED ph /ORP/ Temperature CONTROLLER JENCO ELECTRONICS,LTD. MANUFACTURER OF PRECISION INSTRUMENTS CONTENTS I. INITIAL INSPECTION and ASSEMBLY 3 MOUNTING

More information

Conductivity and TDS Meter Pen Style Water Quality Meter

Conductivity and TDS Meter Pen Style Water Quality Meter User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Conductivity and TDS Meter Pen Style Water Quality Meter Model EC150

More information

User's Guide. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500

User's Guide. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500 User's Guide ExStik EC500 ph/conductivity / TDS / Salinity / Temperature Meter EC500 Introduction Congratulations on your purchase of the ExStik EC500 ph/conductivity/total Dissolved Solids (TDS) / Salinity

More information

Instruction Manual Temp JKT Temperature Meter Series

Instruction Manual Temp JKT Temperature Meter Series Instruction Manual Temp JKT Temperature Meter Series 68X243615 Technology Made Easy... Rev. 2 11/03 Preface This manual serves to explain the use of the Temp JKT temperature meter. This manual functions

More information

WK7200. Water Quality Test Kit USER S MANUAL

WK7200. Water Quality Test Kit USER S MANUAL WK7200 USER S MANUAL Water Quality Test Kit INTRODUCTION: Thank you for selecting model WK7200 microprocessor-based waterproof Water Quality Test Kit. It is used to measure a wide range of ph, ORP, Conductivity,

More information

User Guide. ExStik FL700. Fluoride Meter

User Guide. ExStik FL700. Fluoride Meter User Guide ExStik FL700 Fluoride Meter Introduction The model FL700 is a system specifically designed for the quick and accurate measurement of fluoride ions in drinking water and other aqueous samples.

More information

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods ENTER 8. Warranty Oakton Instruments warrants this product to be free from significant deviations in material and workmanship for a period of three year from the date of purchase (excludes electrode).

More information

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter

USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter USER MANUAL AD 3000 EC/TDS/Temperature Bench Meter www.adwainstruments.com 1 Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting operations. This instrument

More information

CLEAN PH200/ PH500 ph/ mv/ ORP Ion Versatile Water Analysis Meter www.cleaninst.com E-mail: CS@cleaninst.com CLEAN INSTRUMENTS CO. LTD 2F No.140, Zhongxiao St., Zhonghe Dist., New Taipei City,Taiwan ph/

More information

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD.

JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD. OPERATION MANUAL JENCO MODEL 6311 MICROCOMPUTER BASED ph / ORP and Temperature CONTROLLER JENCO INSTRUMENTS, INC. JENCO ELECTRONICS, LTD. 7968 ARJONS DR., SUITE C P.O. BOX LINKOU-117 SAN DIEGO, CA 92126

More information

Instruction Manual CON 400 and CON 410 Waterproof Hand-held Conductivity/TDS Meter

Instruction Manual CON 400 and CON 410 Waterproof Hand-held Conductivity/TDS Meter Instruction Manual CON 400 and CON 410 Waterproof Hand-held Conductivity/TDS Meter Technology Made Easy... 68X248904 Rev 3 01/04 Preface This manual serves to explain the use of the Waterproof CON 400/410

More information

The Economy Conductivity Benchtop Meter

The Economy Conductivity Benchtop Meter CON 500 The Economy Conductivity Benchtop Meter Conductivity meter SET MODE HOLD ENTER RANGE MEAS ON/OFF MI MR Model no: WD-35610-00 WD-35610-05 897 1997 00701-55 2 Table of contents 1. Introduction...4-5

More information

Global Water Instrumentation, Inc.

Global Water Instrumentation, Inc. Global Water Instrumentation, Inc. 11390 Amalgam Way Gold River, CA 95670 T: 800-876-1172 Int l: (916) 638-3429, F: (916) 638-3270 PRODUCT NAME: 3101 Conductivity Controller - 1 - Global Water s Conductivity

More information

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at User Manual ExStik EC500 ph/conductivity / TDS / Salinity / Temperature Meter EC500 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the

More information

MULTI- PARAMETER TESTER

MULTI- PARAMETER TESTER QUICK GUIDE MULTI- PARAMETER TESTER 35 ph/ Conductivity/ TDS/ Salinity/ Temperature PCSTestr35, PCTestr35, PTTestr35 Technology Made Easy... Part of Thermo Fisher Scientific 68X441601 Rev 0 Jan 08 Thank

More information

Platinum RTD Thermometer MODEL NO

Platinum RTD Thermometer MODEL NO Platinum RTD Thermometer MODEL NO. 93410-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com

More information

HI 9828 Multiparameter Water Quality Meter...

HI 9828 Multiparameter Water Quality Meter... HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe

More information

HI 9828 Multiparameter Water Quality Meter...

HI 9828 Multiparameter Water Quality Meter... HI 9828 Multiparameter Water Quality Meter... Backlit LCD can display up to 12 Measurements at a time Feature Highlights Display up to 12 parameters Graphic LCD with backlight Meter features IP67 and probe

More information

Instruction Manual. Laboratory EC Meter NeoMet Series. EC-400L (EC/TDS/ Salinity/Temp)

Instruction Manual. Laboratory EC Meter NeoMet Series. EC-400L (EC/TDS/ Salinity/Temp) Laboratory EC Meter NeoMet Series EC-400L (EC/TDS/ Salinity/Temp) istek, Inc. Room #1011, Hanshin IT?Tower 235 Guro-Dong, Guro-Gu, Seoul, Korea Phone : +82-2-2108-8400 Fax : +82-2-2108-8430 Website: www.istek.co.kr

More information

AquaController Apex Probe Module 2

AquaController Apex Probe Module 2 AquaController Apex Probe Module 2 Setup Guide Table of Contents PROBE MODULE 2 INTRODUCTION... 1 FEATURES... 1 PHYSICAL INSTALLATION... 1 Initial Connections... 1 Startup... 2 VERIFY THE INSTALLATION...

More information

Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter

Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter English Cond Thermo Scientific Orion Star A222 and Star A322 Portable Conductivity Meter Instruction Sheet Preparation Power Source 1. Power adapter (sold separately) a. Select the appropriate wall socket

More information

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately:

ELECTROCHEMISTRY. BOECO ELECTRODES The electrodes are not included with the ph meters and have to be ordered separately: BOECO PORTABLE PH/ORP/TEMP METER MODEL PT-380 A Simultaneous displays ph or mv and temperature. A Convenient calibration with automatic buffer recognition of European and US buffer sets. Calibration data

More information

Instruction Manual Cond 6+ Conductivity/Temp TDS 6+ TDS/Temp Salt 6+ Salinity/Temp

Instruction Manual Cond 6+ Conductivity/Temp TDS 6+ TDS/Temp Salt 6+ Salinity/Temp Instruction Manual Cond 6+ Conductivity/Temp TDS 6+ TDS/Temp Salt 6+ Salinity/Temp 68X243635 Rev 0 02/09 Preface This manual serves to explain the use of the Conductivity, TDS, and Salinity handheld meters.

More information

Sound Level Pen Instruction Manual

Sound Level Pen Instruction Manual Sound Level Pen 840018 Instruction Manual TABLE OF CONTENTS 1. INTRODUCTION...................2 2. DESCRIPTION.................... 3 3. OPERATING INSTRUCTIONS........... 4 PRECAUTIONS AND MAINTENANCE.......4

More information

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR

MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR MODEL 3150 SUSPENDED SOLIDS ANALYZER MODEL 35/35L OPTICAL SUSPENDED SOLIDS SENSOR REVISION 22 August 2016 Insite Instrumentation Group, Inc 80 Whisperwood Blvd. Suite 107 Slidell, LA 70458 Phone: (985)

More information

MODEL 3100 DISSOLVED OXYGEN ANALYZER MODEL 30 OPTICAL DISSOLVED OXYGEN SENSOR

MODEL 3100 DISSOLVED OXYGEN ANALYZER MODEL 30 OPTICAL DISSOLVED OXYGEN SENSOR MODEL 3100 DISSOLVED OXYGEN ANALYZER MODEL 30 OPTICAL DISSOLVED OXYGEN SENSOR REVISION 22 August 2016 Insite Instrumentation Group, Inc 80 Whisperwood Blvd. Suite 107 Slidell, LA 70458 Phone: (985) 639-0006

More information

DPH230SD USER S MANUAL

DPH230SD USER S MANUAL DPH230SD USER S MANUAL ph METER WITH DATALOGGING SD CARD Please read this manual carefully and thoroughly before using this product. TABLE OF CONTENTS Introduction................................. 3 Key

More information

POCKET DIGITAL REFRACTOMETERS ~

POCKET DIGITAL REFRACTOMETERS ~ POCKET DIGITAL REFRACTOMETERS 300051 ~ 300055 INSTRUCTION MANUAL SPER SCIENTIFIC LTD. CONTENTS 1. Introduction... 3 2. Panel Description... 4-5 3. Calibration... 6 4. Measurement... 7 Models with Multiple

More information

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax: OPERATION MANUAL /ORP 300 (Cat. No. 0580212) MICROCOMPUTER BASED /ORP/ Temperature CONTROLLER 625 East Bunker CT, Vernon Hills, IL 60061-1844 Phone: 800-32-4340, Fax: 847-247-2929 E-mail: info@coleparmer.com,

More information

Bante901 Benchtop ph/conductivity Meter Instruction Manual

Bante901 Benchtop ph/conductivity Meter Instruction Manual Bante901 Benchtop ph/conductivity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante901 Benchtop ph/conductivity Meter 1 Introduction Thank you for selecting the Bante901 ph/conductivity meter.

More information

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL PROGRAMMABLE DIGITAL REFRACTOMETER 300037 INSTRUCTION MANUAL 1 CONTENTS INTRODUCTION... 2 PANEL DESCRIPTION... 3 FACEPLATE & LCD DISPLAY...3 OPERATING INSTRUCTIONS General Measurement...4 Calibration Procedures...4

More information

User Guide. Conductivity Meter. Model EC210

User Guide. Conductivity Meter. Model EC210 User Guide Conductivity Meter Model EC210 Introduction Thank you for selecting the Extech EC210 conductivity meter which simultaneously displays conductivity and Temperature. Conductivity is measured with

More information

Visit us at Back to the Extech DO600 Product Page

Visit us at   Back to the Extech DO600 Product Page User's Guide II ExStik DO600 Dissolved Oxygen Meter RECALL Dissolved Oxygen DO600 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com

More information

Platinum RTD Thermometer MODEL NO

Platinum RTD Thermometer MODEL NO Platinum RTD Thermometer MODEL NO. 93410-00 Cole-Parmer Instrument Co. 625 East Bunker Court Vernon Hills, Illinois U.S.A. 60061-1844 (847) 549-7600 (847) 247-2929 (Fax) 800-323-4340 www.coleparmer.com

More information

AquaShock ph Meter K

AquaShock ph Meter K AquaShock ph Meter 850057K 7720 E. Redfield Rd. Suite #7, Scottsdale, AZ 85260 Tel: (480) 948-4448 Fax: (480) 967-8736 Web: www.sperscientific.com AquaShock ph Meter 850057K Copyright 2011 by Sper Scientific

More information

Advanced Datalogging Thermometer. Instruction Manual

Advanced Datalogging Thermometer. Instruction Manual Advanced Datalogging Thermometer 800008 Instruction Manual Advanced Datalogging Thermometer - 800008 Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual

More information

DELUXE FAST RESPONSE WATERPROOF DIGITAL STEM THERMOMETER USER S MANUAL

DELUXE FAST RESPONSE WATERPROOF DIGITAL STEM THERMOMETER USER S MANUAL DELUXE FAST RESPONSE WATERPROOF DIGITAL STEM THERMOMETER USER S MANUAL DWS350SSQ PPlease read this manual carefully and thoroughly before using this product. INTRODUCTION Thank you for purchasing General

More information

HI 2300 Auto-ranging Microprocessor EC/TDS/NaCl/ºC Bench Meter

HI 2300 Auto-ranging Microprocessor EC/TDS/NaCl/ºC Bench Meter / LOCK C Instruction Manual HI 2300 Auto-ranging Microprocessor EC/TDS/NaCl/ºC Bench Meter T Functions Select Measurement RANGE Range ALT GLP ATC TC SETUP Start Calibration LOCK Lock Current Range Change

More information

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

Bante 221 Portable ph/orp Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD Bante 221 Portable ph/orp Meter Instruction Manual BANTE INSTRUMENTS CO., LTD Bante 221 Portable ph/orp Meter 1 Introduction Thank you for selecting the Bante 221 portable ph/orp meter. This manual provides

More information

Tracer ph/tds/salt PockeTester TM Code 1766

Tracer ph/tds/salt PockeTester TM Code 1766 Tracer ph/tds/salt PockeTester TM Code 1766 Do Not allow ph sensor to dry out. Store Upright Before first use, tap meter against palm to move electrolyte to tip. See pages 10 and 19. ph/conductivity/tds/salinity

More information

Instruction Manual. PC 700 ph/mv/conductivity/ºc/ºf Bench Meter. Technology Made Easy...

Instruction Manual. PC 700 ph/mv/conductivity/ºc/ºf Bench Meter. Technology Made Easy... Instruction Manual PC 700 ph/mv/conductivity/ºc/ºf Bench Meter Technology Made Easy... Part of Thermo Fisher Scientific 68X541704 Rev 3 Mar 2013 TABLE OF CONTENTS 1. INTRODUCTION... 1 2. GETTING STARTED...

More information

SP-400 Portable Water Analyzer Operation Manual. Rev. A Firmware version 1.02

SP-400 Portable Water Analyzer Operation Manual. Rev. A Firmware version 1.02 SP-400 Portable Water Analyzer Operation Manual Rev. A Firmware version 1.02 Pyxis Lab, Inc 120 Jeffrey Ave Holliston, MA 01746 USA www.pyxis-lab.com service@pyxis-lab.com 1 Contents 1 General Description...

More information

PH SD Card Datalogger. Instruction Manual

PH SD Card Datalogger. Instruction Manual PH SD Card Datalogger 850060 Instruction Manual PH SD Card Datalogger 850060 Copyright 2010 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or

More information