Switched Relay Controller - Relay Panel with Breakers

Size: px
Start display at page:

Download "Switched Relay Controller - Relay Panel with Breakers"

Transcription

1 Installation Instructions Model # SC-RPB INS #

2 Contents Contents Description Page Safety Please Read This First... 3 Introduction... 3 Welcome... 3 Range Overview... 4 Specifications... 4 Cabinets Dimensions... 4 Mounting... 5 Location and Spacing... 5 Important Points for Considerations... 5 Ambient Atmosphere Requirements... 5 Accessing the Mounting Holes... 5 Supply Wiring... 6 Wiring Flow... 6 Load Wiring... 7 High Voltage Load Wiring... 7 Total Load Per Channel... 7 Load Wire Gauges... 7 Low Voltages Load Wiring... 7 Low Voltage Load Wiring Flows... 7 Indicators... 8 Control Wiring... 8 Multiple Control Protocols... 8 Termination... 9 Control Panel Operation... 9 Using the Control Panel... 9 Accessing the Menus Menu Navigation Overriding Channels Viewing Power Data Readings...11 Setting Communications Options...11 Changing the Operation Menu Password

3 Introduction WARNING HAZARDOUS VOLTAGES. DISCONNECT FROM SUPPLY BEFORE REMOVING COVERS. NO USER SERVICEABLE PARTS INSIDE. SERVICE BY QUALIFIED PERSONNEL ONLY. PLEASE READ THIS FIRST SAFETY The Source Controller is designed, built and tested to strict safety regulations. By following the steps listed below and elsewhere within this guide, you can ensure safe installation and operation of these controller units. The Source Controller must be installed only by a qualified electrician The installation must comply with the appropriate electrical codes and regulations in force in your area The Source Controller are designed for indoor installation and use only. The units can, however, be used to control appropriately certified exterior lighting fixtures Ensure that all wiring used conforms fully to local specifications and is sufficiently rated for the installation All new wiring must be fully verified before applying power The high voltage supply should be fed to the Source Controller via an external isolation breaker with sufficient capacity for the planned installation All Source Controllers exceed the weight limit for one person lifting - always use at least two people when lifting and mounting the units Ensure that the supply is fully isolated at an external breaker before removing the chassis covers. Test that power has been removed before starting to handle conductors Ensure that high voltage and low voltage wiring remains separate Introduction Welcome The ilumin Switched Relay Controller range from Eaton s Cooper Controls Business has been designed to provide maximum flexibility in both installation and operation. Every model in the range can accept a variety of industry standard control options, from icannet to DMX, from ethernet to RS-485. Similarly, every model can drive a wide range of lighting loads, from incandescents to dimmable fluorescents, from non-dim apparatus to DALI (Canada and Mexico only) digital modules. Much care and attention has been applied to the installation and maintenance of the Switched Relay Controller range. Each model provides clear, logical cable routing and every high voltage channel is controlled by an individual, easy to replace circuit. 3

4 Introduction Range Overview Each model is specified using a part number in the following format: For SC-RPB (Relay Panels with Circuit Breakers) SC RPB 1P ML 20 S 18 3 HF1 Product SC = Source Controller Voltage 12, 277V, 347V Number of Circuits 18, 30, 42 Interior Options Blank 0, 0-1 dimming channels HF1 12, 0-1 dimming channels HF2 24, 0-1 dimming channels Number of Two Pole Relays (Two Pole Relays count as 2 Single Pole Relays) 1 to 24 Source Controller Type RPB = Relay Panel w/ Breakers Phase 1P = Single Phase 3P = Three Phase Enclosure/Interior Options S = Surface S-PW = Surface Prewired Branch Breaker Rating (Amps) 20 = 20 Amp (Default) Panel Feed ML = Main Lugs Number of Single Pole Relays 18 = 0-18 Relays 36 = 0-36 Relays 48 = 0-48 Relays Specifications The numerous models within the Switched Relay Controller range share the following key specifications. Information specific to each cabinet model are provided elsewhere throughout this guide. All channels provide switched (non-dim) control as standard All channels protected by thermal magnetic circuit breakers Power monitoring for each circuit, phase and the total panel Optional support of 0-1 dimming loads with addition of HF card. (DALI in Canada and Mexico) Selectable low voltage load control available per channel for dimmable ballast control Low maintenance and quiet operation thanks to fanless, convection cooled operation Support for multiple control protocols: ican for links to multiple control sources; DMX512A for links with entertainment systems; RS-485 for integration with building management schemes and Ethernet for connection to a variety of systems Dual, volt-free switch inputs with programmable responses for integration with emergency control devices, building management systems, etc. Compact wall mounted design with easy access to all internal items and lockable front panel door for added security Intuitive control panel provides straight forward programming and configuration of the system. The control panel allows a base level installation to be configured without the use of separate PC programming Cabinet Dimensions Three overall cabinet sizes are available as shown. 18 circuit cabinet Packed: 150 lbs Unpacked: 140 lbs 30 circuit cabinet Packed: 180 lbs Upacked: 160 lbs 54 in. ( mm) 76 in. ( mm) 24 in. 6 in. (609.6 mm) (152.4 mm) 24 in. (609.6 mm) 6 in. (152.4 mm) 4

5 Mounting 40 circuit cabinet Packed: 260 lbs Unpacked: 160 lbs 90 in. ( mm) 24 in. (609.6 mm) 6 in. (152.4 mm) Important Points for Consideration Allow adequate space for future maintenance of the unit. Do not install in a location that will later be difficult to access The Switched Relay Controller is designed to be mounted vertically During operation, the Switched Relay Controller will produce audible noise caused circuit relays within the unit. Take these matters into consideration when deciding on a suitable mounting position SC-RPB 18: 54 H X 24 W X 6 D (up to 18 relays) SC-RPB 36: 76 H X 24 W X 6 D (up to 36 relays) SC-RPB 48: 90 H X 24 W X 6 D (up to 48 relays) Mounting Location and Spacing The Switched Relay Controller models are all fully convection cooled, therefore it is vitally important to ensure that each unit is installed in a ventilated location that permits sufficient airflow and provides the correct ambient conditions. Ensure that the minimum distances to walls and other equipment shown in the diagrams below are maintained. Also ensure that the stated ambient atmosphere requirements are not exceeded. Ambient Atmosphere Requirements Temperature: 32º F to 104º F (0º C to +40º C) Humidity: 0 to 95% non-condensing Accessing the Mounting Holes The mounting holes are located within the rear panel of the Switched Relay Controller. To access the mounting holes (and circuit wiring terminals) it is necessary to remove the front panel. To Remove the Front Panels CAUTION If removing panels on a previously installed Switched Relay Controller, ensure that all power inputs are isolated first. 1. Open the main panel door. 2. Remove the two upper and two lower security screws that hold the main panel in place. Loosen the keyed screws on the front panel. 3. Carefully lift and remove the front panel from the keyed screws. To Replace the Front Panels 1. Carefully place the front panel over the keyed screws, verify alignment. 2. Install the security screws behind the door. 3. Tighten the front panel screws MIN 360 mm 5

6 Supply Wiring R0.207 R R R0.207 R R0.207 R R Supply Wiring Wiring Flow The Switched Relay Controller range has been designed to provide a clear layout and logical progression for all power circuits. The main supply conductors enter at the bottom of the panel connect directly to the input lugs. Input power is then fed to a central bank of breakers and distributed from there to each of the individual circuit cards. Two vertical wireways provide clear routes from the circuit card outputs up to the earth terminals and the exit knockouts within the top panel of the chassis. The diagram shown right indicates a typical wiring flow with the high voltage load wiring from the various channels (and their earth connections) exiting from the top panel. Low-voltage connections for ICANnet, DMX512, RS-485, Ethernet, Contact Closures, 0-1 Dimming come into the center top section of the enclosure. Branch Circuit Breaker direct feed to loads not controlled by relays in the enclosure. 90 in. ( mm) 24 in. (609.6 mm) Relay connections to lighting loads (conduit may enter through side or side top of the enclosure) Branch Circuit Breaker feeds to relays Main Breaker feed to the Main Lugs Barriers (ordered separately) provide to separate voltages or sources. (All circuits below barrier must come from the internal branch circuit breakers) 6

7 Load Wiring Load Wiring High Voltage Load Wiring Each load channel is served by a dedicated control card. For each card, load connections are made using a two terminal screw block connector. Available at the connection block are line and load connections. The low voltage load wiring circuits are located in the center section of the control panel, accessible behind the low voltage door. Connections are made easy by using removable plug blocks which snap into terminals mounted on the circuit boards as shown: Total Load Per Channel The load on each channel must not exceed 16A. Load Wire Gauges Load wiring must be sized according to the nature of the channel load(s) and with strict regard to regulations and codes in force within your locality. The maximum permissible wire gauges accepted by the connector blocks are: Solid: 8 AWG (6 mm 2 ) Stranded 2R wire Neutral A separate neutral connection is available on each relay card for voltage reference only. No load current need flow through this conductor allowing it to be much smaller than the line and load conductors. Low Voltage Load Wiring Each channel can be individually configured to support any of the following low voltage load control standards: 0-1, DSI or broadcast DALI (DSI and DALI - Canada and Mexico Only). The high voltage sections for each channel continue to provide switched hot outputs to power the controlled loads. Note: Neutral Support for multiple low voltage load control standards may not be permissible in certain countries. In such cases, the required control standard must be stated when ordering. For each circuit, the low voltage control protocol to be used is selected using the configuration menu on the control panel. The programming of the Switched Relay Controller range channels is covered within the accompanying System Manual. Note: DALI s for each channel are output in broadcast mode only - it is not possible to individually address multiple DALI luminaires on the same control wire. The low voltage load control circuits are PELV (Protected Extra Low Voltage). Low Voltage Load Wiring Flows Low voltage wiring should enter through the top center of the lighting cabinet, the designated low voltage wiring channel. Use appropriate conduits and couplers to link with raceways or cable runs, as necessary. IMPORTANT: Low voltage load wiring should be installed with a suitable separation to parallel high voltage cables, according to local and national codes. 7

8 Control Wiring Indicators An indicator is assigned to each low voltage output channel to provide quick visual feedback. In each case, the indicator (located next to the output connectors) will mimic the dimmed status of the associated channel, from zero to full brightness. Connections for the ican net, DMX512A and RS-485 protocols are made using removable plug blocks which snap into terminals mounted on the control circuit board. A standard RJ45 socket is provided for the ethernet connection. In addition, a separate connector block (labeled Contact Closure ) allows two volt-free switch inputs from external systems. Subject to configuration menu settings, these inputs can be used to affect selected channels. The control connections are located just above the control panel, which is accessed by swinging open the inner low voltage access door. Indicators Control Wiring Multiple Control Protocols To ensure maximum versatility, the Switched Relay Controller provide full compatibility with a range of control protocols, including: ican net DMX512A RS-485 Ethernet Ethernet Link DMX- DMX+ OV Shield Switch Input 1 Switch Input 2 DMX Contact Closure RS-485- RS-485+ OV Shield +12V (Red) CAN-H (White) Drain (Gray) CAN-L (Blue) (Black) RS-485 ican 8

9 Control Panel Operation Termination The ican, DMX and RS-485 are daisy-chain protocols that all require termination on the devices located at either end of the chain. Device Device Device Universal T Source Controller T Control Panel Operation Using the Control Panel Each Switched Relay Controller provides a control panel to make configuration and operation as straight forward as possible. The main configuration procedures within the control panel are covered within the accompanying System Manual. This section provides a brief overview of the Operation menu. The Switched Relay Controller provide jumper links adjacent to the ican, DMX and RS-485 connectors. As standard all of these interfaces are terminated. To remove termination for a particular bus, move the associated termination jumper from the upper two pins to the lower two pins. Termination ON Termination OFF TERM TERM Numeric keypad plus arrow keys, Escape (ESC) button and Enter (ENT) button for menu navigation ESC # Eaton s Cooper Controls 12:00 am June 04, 2008 Device # OK LINK ENT ican DMX 485 DATA Clear Text Display Link and Status Indicators Flashes Regularly to Indicate Correct System Operation When ON, indicates that the timeclock function is enabled. Where multiple SC-UN units are linked, only one unit will light this indicator Illuminates when an error condition occurs. The display screen will provide further information about the nature of the fault Valid Ethernet Link Detected OK LINK ican DMX 485 DATA Flashes when data is present on icanbus link ON when DMX link is enabled, flashes when data is present on DMX link ON when RS- 485 channel is enabled, flashes when data is present on RS- 485 link Flashes when data is present on Ethernet link 9

10 Control Panel Operation Accessing the Operation Menu During normal service of the Switched Relay Controller, the control panel screen shows only the time, date and device number. To Access the Operation Menu 1. Press the ENT button to display the Select Access Level menu. 2. With the Operation option highlighted, press the ENT button. 3. If requested, enter the four digit operation password and press the ENT button. Note: When the unit is supplied, there is initially no password - see the section Changing the operation menu password to set one. 4. If the password is accepted, the main Operation Menu will be displayed. Operation Password XXXX Operation Menu Channel override Timeclock manager Power data Menu Navigation Within the control panel menu system, use the following buttons to navigate: Use the arrow buttons to move highlight bar to the required option. ENT Press to enter an option or to save your changes to an item. ESC Press to escape from an option to the previous level. Operation Menu Contents The operation menu provides the following options: Operation Help Output Override Timeclock Manager Power Data All Outputs Each Output Select Scene Select Access Level Operation Contact Cooper Time & Date Events Coordinates Daylight Saving Timestamp Frequency Enable/Disable Total Power Display by Phase Display by Channel Overriding Outputs On occasions it may be necessary to override the levels of one or more Outputs. This option provides the ability to affect Outputs individually or all of them collectively. You may also select any of the first 128 standard Scenes or even the Emergency Scene (Scene 132). To Override Outputs 1. From the Operation menu, highlight the Output Override option and press the ENT button. The display will show the available options: Override -Options All Outputs Each Output Select Scene 2. Use the or buttons to highlight the required option and press the ENT button to select: All Outputs Note: Override: All Outputs Enter Level 50% Each Output Override: Each Output Output 1 0% Output 2 0% Output 3 0% Output 4 0% Select Scene Override: Select Scene Select Scene 1 Use and, or the keypad (and ENT ) to select the dimming level (0 to 100%). Press the ESC button to exit Use and to highlight the required Output. Use and, or the keypad (and ENT ) to select the dimming level (0 to 100%). Press the ESC button to exit. To Flash the selected Ouput press the button. Press the button a second time to stop the channel from flashing. Use and, or the keypad (and ENT ) to select the required Scene. Press the ESC button to exit. If there are no settings within a selected scene, the display will show Scene Empty. 3. Press the ESC button to return to the operation menu. Communications icannet Ethernet DMX RS-485 Contact Inputs OFF/ON OFF/ON OFF/ON OFF/ON OFF/ON 10

11 Control Panel Operation Viewing Power Data The Power Data section provides useful feedback and confirmation of the total power demanded within the SCRP Switched Relay Controller, listed as a total for the whole unit, as totals by phase or values for individual Outputs. To View Power Data from the Menu 1. From the Operation menu, highlight the Power Data option and press the ENT button. The display will show the avaliable options: Power Data Total Power xxx kw Display by Phase Display by Output 2. Use the or buttons to highlight the Display by Output option and press the ENT button to select: Output 1 Voltage 120 V 60Hz Current 7.2 A Power 0.8 kw Pwr: 100% HF: 100% 3. Use and to view the required Output number. 4. When finished, press the ESC button to exit to the previous level and then press the ESC button to return to the operation menu. Note: Dimming level of the high voltage side of the Output Total power currently being supplied by the whole Source Controller Voltage, Current and Power values for the chosen Output Dimming level of the low voltage HF control side of the Output On SCRP controllers only, please refer to the Total Power information and Display by Output information only. Display by phase may not be accurate as feeding breakers are not housed within the controller. Setting Communications Options The Communications options section allows you to determine which control protocols should be enabled. Changing the Operation Menu Password The unit uses two passwords, one for the operation menu and another for the configuration menu. When the unit is supplied, there are initially no passwords. You are strongly recommended to set separate operation and configuration menu passwords at the earliest opportunity. After doing so, ensure that the relevant users are informed of the new passwords. To Set/Change the Operation Menu Password 1. From the Configuration menu, select the Password Manager option and press the ENT button. If a previous password has been set, the screen will prompt you to enter the current password: Password manager Enter current password XXXX Use the keypad to enter the current password. As you type, each digit will be represented by an X. If you enter a character incorrectly, press the ESC button to erase it. When you have entered the code, press the ENT button. 2. Highlight the required password to set/change: Operation or Config, then press the ENT button. Password manager Choose password Operation Config 3. Enter your new code (4 digits) and press the ENT button. Then re-enter the code again and press the ENT button. If the two new codes match, you will be given the option to save: Change password? Yes 4. Highlight the Yes option and press the ENT button. No To Set Communications Options 1. From the Operation menu, select the Communications option and press the ENT button. The screen will show the available control protocols and their current settings: Communications - options icannet On Ethernet On DMX On v RS485 On 2. Highlight the option that you wish to alter and then press the button to change its ON/OFF status. 3. Press the ENT button to save your changes and exit. 11

12 WARRANTIES AND LIMITATION OF LIABILITY Please refer to under the Legal section for our terms and conditions. Eaton 1000 Eaton Boulevard Cleveland, OH United States Eaton.com Eaton s Cooper Controls Business 203 Cooper Circle Peachtree City, GA CooperControl.com 2014 Eaton All Rights Reserved Printed in USA P/N: Eaton is a registered trademark. All trademarks are property of their respective owners.

SCD96 DMX Output Interface. Installation guide

SCD96 DMX Output Interface. Installation guide SCD96 DMX Output Interface Installation guide Contents Introduction 2 Welcome 2 Dimensions 2 Specification 2 Safety 3 Please read this first 3 Mounting 4 Location and spacing 4 Ambient atmosphere requirements

More information

Model# CKM18 Model# CKM36 Model# CKM48 WARNING

Model# CKM18 Model# CKM36 Model# CKM48 WARNING Installation Instructions Model# CKM18 Model# CKM36 Model# CKM48 WARNING HAZARDOUS VOLTAGES. DISCONNECT FROM SUPPLY BEFORE REMOVING COVERS. NO USER SERVICEABLE PARTS INSIDE. SERVICE BY QUALIFIED PERSONNEL

More information

EISSBox OpenADR 2.0b

EISSBox OpenADR 2.0b Installation Instructions EISSBox EISSBox OpenADR.0b INS # Energy Interop Server & System (EISS ) EISSBox.0b Local Unit Installation Guide. IPKeys EISSBox is an OpenADR.0bcertified end point that is capable

More information

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet General Information ControlKeeper 4 Installation Sheet Model# CK4-120NO- Model# CK4-277NO The ControlKeeper-4 model is shipped in one package and is configured with either a 120V or a 277V transformer.

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm

DMC2. Installation Guide Version 1.0. Area for main photograph. Area for insert photo. W: 46.1mm up to 79 mm H: 46.1mm Area for main photograph Area for insert photo W: 46.1mm up to 79 mm H: 46.1mm X: 12.6mm absolute on page Y: 132.6mm abs on page This insert has a shadow DMC2 Installation Guide Version 1.0 Contents DMC2

More information

Instruction Manual. Contents

Instruction Manual. Contents SceneSelect II Scene-setting and Dimming System SBD410 HF BALLAST CONTROLLER Instruction Manual Warning... 2 Features... 2 Important Safeguards... 2 Internal View......3 Mounting... 4 Supply & Load Cable

More information

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring

User Manual. JS-ICON 624 PACK Portable Dimmer Pack. JOHNSON SYSTEMS INC. Spring User Manual JS-ICON 624 PACK Portable Dimmer Pack JOHNSON SYSTEMS INC. Spring 2007 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

ETC Installation Guide

ETC Installation Guide Unison Foundry Overview The Unison Foundry provides fully-rated 20A relays for switched power control with 0 10V dimming for compatible fluorescent ballasts and LED drivers. The provides two outputs of

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be

More information

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis.

2.) Cabinet setup and preset data shall, as standard, be fully user programmable on a per cabinet or system wide basis. A21 DIMMER CABINET SPECIFICATION. GENERAL. A.) Overview. 1.) The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist

More information

Single Channel Lighting Control Module

Single Channel Lighting Control Module Product Guide LMS-MIN-LCM, LMS-MIN-LCM-DIM, LMS-MIN-LCM-EM Single Channel Lighting Control Module The LMS-MIN-LCM series of lighting control modules (LCMs) are used as part of the LMS Lighting Management

More information

Installation and User Guide

Installation and User Guide D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect

More information

CS XL XM. EcoSystem Bus Supply

CS XL XM. EcoSystem Bus Supply EcoSystem An EcoSystem lighting network containing more than one ballast, module, or driver requires an EcoSystem. This supply powers one or two independent EcoSystem buses with up to 64 ballasts or ballast

More information

Dim levels for each system output may be controlled by any of the following methods:

Dim levels for each system output may be controlled by any of the following methods: Applied Electronics Bravo Series Dimming System Rack-Mount Architectural l SA12/2400A and l SA12/2400E Setup and Operation Instructions 1.0 Scope This document details the setup and operation requirements

More information

NCH-1000 (Multiple Breaker Types) Installation Instructions

NCH-1000 (Multiple Breaker Types) Installation Instructions 20M1 12345678 NCH-1000 (Multiple Breaker Types) Installation Instructions DOC. #560502100 C 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in compliance

More information

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Clipsal Bus Couplers Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems Instruction Bulletin Retain for future use. Clipsal Bus Couplers 63249-420-236A2 Instruction

More information

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A

DTS 310. DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter. Page 1. Measurlogic MQ A DTS 310 DIN Rail Mounted, Indoor Rated Revenue Grade Electrical Sub-meter Page 1 1 PRODUCT OVERVIEW... 3 1.1 SUPPLIED ITEMS... 3 1.2 DOCUMENT CONVENTIONS... 4 1.3 PRODUCT SPECIFICATION... 4 1.3.1 Current

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS

Lighting Control Panel 16 and 24 INSTALLATION INSTRUCTIONS PRECAUTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. CAUTION: USE COPPER CONDUCTOR ONLY CAUTION: RISK OF ELECTRICAL SHOCK. To prevent electrical shock, turn off power at the circuit breaker before installing

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

DBC x 10A HF Ballast Controller Installation Manual

DBC x 10A HF Ballast Controller Installation Manual DBC1210 12 x 10A HF Ballast Controller Installation Manual contents Warning.. 2 Hardware Controls... 7 Features.. 2 Troubleshooting. 8 Important Safeguards.. 2 Specification.. 8 Internal View.. 3 Mounting.

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960, PMMC-1000 PM Series Power Meter Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices.

More information

Control different load types with one device

Control different load types with one device Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03 Digital Lighting Systems, Inc. PD26 Two Channel Dimmer and Switch Packs PROTOCOL PD26 S2 S USER'S MANUAL PD26-UM Rev. E - 02/03 Digital Lighting Systems PD26 User's Manual - Page GENERAL DESCRIPTION The

More information

Installation and User Guide

Installation and User Guide Installation and User Guide 458UNI8 8Channel Universal Dimmer Module Introduction The 458/UNI8 is an 8channel universal, digital transistor, dimmer module. Each channel s mode can be selected for either

More information

QuantumR Light Management Hub (QP2)

QuantumR Light Management Hub (QP2) Quantum 369375f 1 11.05.15 QuantumR Hub (QP2) The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, and QS devices

More information

GCI-5K INSTALLATION AND OPERATOR S MANUAL

GCI-5K INSTALLATION AND OPERATOR S MANUAL GCI-5K INSTALLATION AND OPERATOR S MANUAL Grid-tied inverter for wind Ningbo Ginlong Technologies 1 INTRODUCTION 2 SAFETY GUIDELINES AND WARNINGS 3 INSTALLATION 3.1 Selecting a location for the inverter

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

Dim levels for each system output may be controlled by either of the following methods:

Dim levels for each system output may be controlled by either of the following methods: Applied Electronics Bravo Series Dimming System Model SA12/1200 Setup and Operation Instructions 1.0 Scope This document details the setup and operation requirements for Applied Electronics Bravo Series

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

QuantumR Light Management Hub

QuantumR Light Management Hub Quantum 369375e 1 04.02.2015 QuantumR Light Management Hub The Quantum light management hub provides a centralized connection point for Lutron EcoSystem digital ballast modules, Lutron power panels, GRAFIK

More information

DBC1220GL. 12 x 20A HF Ballast Controller Installation Manual. contents

DBC1220GL. 12 x 20A HF Ballast Controller Installation Manual. contents DBC1220GL 12 x 20A HF Ballast Controller Installation Manual contents Warning.. 2 Hardware Controls... 7 Features.. 2 Troubleshooting. 8 Important Safeguards.. 2 Specification.. 8 Internal View.. 3 Mounting.

More information

SNAP Lighting Control Panel

SNAP Lighting Control Panel SNAP Lighting Control Panel Pathway Connectivity s SNAP Lighting Control Panels provide unified DMX512 control of 0-10VDC outputs and relay switching from a single enclosure. Intended for use with LED

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control system for various gas, temperature and humidity detection, control and

More information

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module

EcoSystem One-Line. EcoSystem C5-XPJ-16A Switching Power Module EcoSystem Switching Power Module for Non-Dim Loads LutronR Switching Power Module allows integration of non-dim loads into Lutron s Bus. The Power Module combines digital commands and sensor data to control

More information

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX

Instruction Bulletin. Fiber Optic Switch Packs. SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION CONTENTS OF THE BOX Instruction Bulletin 63249-500-04A3 07/2010 Fiber Optic Switch Packs SLSPSP101 and SLSPSP102 for use with Luminaires INTRODUCTION SLSPSP101 Single Input Switch Pack SLSPSP102 Dual Input Switch Pack The

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits Function description To permit direct communication with the Philips SR interface, we offer two of our best and most innovative sensors: the ED PIR sensor with its patented multi-segment sensor lens and

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11

Z-Wave Certified Wireless Lighting Control. Auxiliary Switch ZW2001 ZW2002 rev. 09/01/11 Z-Wave Certified Wireless Lighting Control Auxiliary Switch 45610 ZW2001 ZW2002 rev. 09/01/11 This auxiliary switch is a component of the JASCO Z-Wave lighting control system and is designed to work with

More information

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual This package is designed to simplify the connections to our Secured Series Hub Plus Controller. This will translate into

More information

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc.

DLA. DMX512 Analyzer. DLA Users Manual SV2_00 B.lwp copyright ELM Video Technology, Inc. DLA DMX512 Analyzer DLA DLA-HH 1 Table Of Contents IMPORTANT SAFEGUARDS... 2 DLA OVERVIEW... 3 CONNECTION... 3 OPERATION... 3 HARDWARE SETUP... 4 DLA-HH (PORTABLE) LAYOUT... 4 CHASSIS LAYOUT... 4 DLA MENU

More information

EnerSure Installation Guide

EnerSure Installation Guide EnerSure Installation Guide Danger!!! The electrical components of this system may contain voltage and /or amperage sufficient to injure or kill. Installation is only to be performed by a licensed, bonded

More information

Strand Lighting Specification

Strand Lighting Specification I. DIGITAL ENVIRON 90 DIMMER CABINET(S) A. GENERAL 1. The dimmer cabinets shall be fully digital, designed specifically for architectural and entertainment lighting applications, and shall consist of 6

More information

IIM Warwick Court. Williamsburg VA REV 5

IIM Warwick Court. Williamsburg VA REV 5 1 1-757-258-3939 100 Warwick Court Williamsburg VA 23185 REV 5 2 Technical Specification >Accuracy Better than + 1% over a range of 1.5 to 200 amperes with power factor ranging from 1 to 0.5 Approved by

More information

Satellite INSTALLATION GUIDE

Satellite INSTALLATION GUIDE N3 Satellite INSTALLATION GUIDE ! WARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breaker or remove fuse. Damage to this product caused by wiring with power on voids

More information

High Power Electronic Gear Installation and operation Guide

High Power Electronic Gear Installation and operation Guide High Power Electronic Gear Installation and operation Guide 96268731 GT 1 KW 230-240 V HQITS-S DGE CLI WI SC 96267936 GT 2 KW 230-240 V HO/HF DGE CLI WI SC IP21 IP21 electronical gear for 1 and 2 kw HIT-DE

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Installation Manual. Alpha 4000 RGB Signs. Before you begin

Installation Manual. Alpha 4000 RGB Signs. Before you begin Installation Manual Alpha 4000 RGB Signs signs are indoor, two-line, full matrix LED displays. These signs can display both text and graphics and can be networked together. Before you begin 1. This manual

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Installing the Cisco AS5400XM Universal Gateway

Installing the Cisco AS5400XM Universal Gateway CHAPTER 3 Installing the Cisco AS5400XM Universal Gateway This chapter guides you through the installation of the Cisco AS5400XM universal gateway and includes the following sections: Setting Up the Chassis,

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

Control different load types with one device

Control different load types with one device Multipurpose Controllers DMC2 Multipurpose Modular Controller Control different load types with one device The Philips Dynalite DMC2 provides multichannel control via two interchangeable output modules.

More information

G-E RR7P3 Latching Relay

G-E RR7P3 Latching Relay LynTec RS-232 Controlled Retrofit Relay Panels Tested, complete package low labor mount next to circuit breaker panel to control C power "hot" lines Time proven, reliable, G-E RR7P3 latching relays snap

More information

PDI Modular Compact Remote Power Panel

PDI Modular Compact Remote Power Panel Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. DALI gateway TW Art. No. : 2099REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

R-LB R-LX Series Installation, Operation & Maintenance Manual

R-LB R-LX Series Installation, Operation & Maintenance Manual Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs

More information

PLPC905GL-3-KNX / PLPC905GL-3-HD-KNX / PLPC905GL-4-KNX / PLPC905GL-4-HD-KNX LightMaster Dimmer Actuator

PLPC905GL-3-KNX / PLPC905GL-3-HD-KNX / PLPC905GL-4-KNX / PLPC905GL-4-HD-KNX LightMaster Dimmer Actuator Features Supply 100-240V 50/60Hz single phase at 16A. Switched Outputs 9 x Maintained NC switched output 9 x Switched outputs, total box load 16A Standard & Heavy Duty (HD) models Mains switched outputs,

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFETY INSTRUCTIONS WARNING RISK OF SEVERE INJURY OR DEATH To reduce the risk of death,

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

THE CTB08D LIGHT CONTOLLER

THE CTB08D LIGHT CONTOLLER THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET

Installation, Operation, and Service Manual SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET Technical Publications SIEMENS HEALTHCARE INTEGRATED ELECTRICAL CABINET for ARTIS Q / Q.ZEN / ONE ARTIS ZEEGO / ZEEGO.ZEN ARTIS ZEE MULTIPURPOSE SINGLE PLANE IECAX480V125A Main Disconnect Panel Bevco Engineering

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

LINAIRE LED WALL WASHER

LINAIRE LED WALL WASHER LINAIRE LED WALL WASHER Extruded aluminum body & tempered glass IP 2 dry/indoor rotary angle Floor mountable DMX-512 controllable DMX COMPATIBLE COLOR-CHANGING DRY LOCATION V AC SPECIFICATION SHEET L 19.69

More information

Document Number: SL estrip 10 RGBW LED Luminaires User Manual

Document Number: SL estrip 10 RGBW LED Luminaires User Manual SL estrip RGBW www.philips.com/showline Document Number: SL estrip RGBW LED Luminaires User Manual Version as of : 26th May 24 SL estrip RGBW User s Manual 24 SL estrip RGBW IMPORTANT INFORMATION Warnings

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02

Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 Dual-Feed 80A Auto Low Voltage Disconnect Panel - 80LVD02 User Manual 1.1 Overview Telect s 80A, -48 Vdc Low-Voltage Disconnect (LVD) panel is a rack-mounted component with coil-operated contactors. These

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 50729 Page of 9 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

Rapier Series Switch Quick Install Guide

Rapier Series Switch Quick Install Guide Rapier Series Switch Quick Install Guide Rapier 24i Rapier 48i Rapier 16fi Rapier Series Switch Quick Install Guide Document Number. Copyright 1999-2006 Allied Telesis Inc. 19800 North Creek Parkway, Suite

More information

BSPD Surge Protective Devices

BSPD Surge Protective Devices BUSSMANN Supersedes December 2016 SERIES BSPD Surge Protective Devices High capacity Type 1 and Type 2 SPDs for overvoltage protection on Contents Description Page Introduction 2 Applications 2 Features

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE

Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE Blue Box BLUE BOX TM LTD PARTS REPLACEMENT GUIDE WARNINGS 1. All servicing should be performed by qualified service personnel. 2. WARNING, Battery may explode if mistreated. Do not recharge, disassemble

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT

A0-10 ANALOG OUTPUT. Instruction Manual April 2001 NALOG OUTPUT A0-10 ANALOG OUTPUT Instruction Manual April 2001 NALOG OUTPUT Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others, and to protect the product and the

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS LIGHTING CONTROL PANELS 16 AND 24 RELAYS INSTALLATION INSTRUCTIONS INSTALLATION OVERVIEW The installation instructions contained in this document are provided as a guide for proper and reliable installation.

More information