SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction 1. Safety notices. Network topologies. Description of the device 4.

Size: px
Start display at page:

Download "SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction 1. Safety notices. Network topologies. Description of the device 4."

Transcription

1 Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Network topologies 3 Description of the device 4 Mounting 5 Connecting up 6 Maintenance and troubleshooting 7 Technical specifications 8 Approvals 9 Dimension drawings 10 02/2017 A2B

2 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION indicates that minor personal injury can result if proper precautions are not taken. NOTICE indicates that property damage can result if proper precautions are not taken. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The product/system described in this documentation may be operated only by personnel qualified for the specific task in accordance with the relevant documentation, in particular its warning notices and safety instructions. Qualified personnel are those who, based on their training and experience, are capable of identifying risks and avoiding potential hazards when working with these products/systems. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be complied with. The information in the relevant documentation must be observed. All names identified by are registered trademarks of Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Division Process Industries and Drives Postfach NÜRNBERG GERMANY A2B P 02/2017 Subject to change Copyright Siemens AG All rights reserved

3 Table of contents 1 Introduction On the Operating Instructions On the product Safety notices Network topologies Description of the device overview Product characteristics SCALANCE XB SCALANCE XB SCALANCE XB004-1LD SCALANCE XB SCALANCE XB SCALANCE XB004-1G SCALANCE XB004-1LDG SCALANCE XB005G SCALANCE XB008G TP ports (twisted pair) Pin assignment Functions Insulation between the TP ports FO port (fiber optic) SCALANCE XB SCALANCE XB SCALANCE XB004-1LD SCALANCE XB004-1G SCALANCE XB004-1LDG LEDs Mounting Safety notices for installation Types of installation Fixing onto standard mounting rails Wall mounting Connecting up Safety when connecting up Wiring rules Operating Instructions, 02/2017, A2B

4 Table of contents 6.3 Power supply Power supply 24 VAC Power supply 24 VDC Grounding Twisted pair cable IE FC RJ-45 Plug Maintenance and troubleshooting Possible sources of problems and how to deal with them Technical specifications SCALANCE XB SCALANCE XB SCALANCE XB004-1LD SCALANCE XB SCALANCE XB SCALANCE XB004-1G SCALANCE XB004-1LDG SCALANCE XB005G SCALANCE XB008G Mechanical stability (in operation) Approvals Dimension drawings Index Operating Instructions, 02/2017, A2B

5 Introduction On the Operating Instructions Purpose of the Operating Instructions These Operating Instructions support you when commissioning networks with the Industrial Ethernet switches of the product line. Validity of the Operating Instructions These operating instructions are valid for the following devices: Device XB004-1 XB004-2 XB004-1LD XB005 XB008 XB004-1G XB004-1LDG XB005G XB008G Article number 6GK BD00-1AB2 6GK BD00-1AB2 6GK BF00-1AB2 6GK BA00-1AB2 6GK BA00-1AB2 6GK GL00-1AB2 6GK GL10-1AB2 6GK GM00-1AB2 6GK GM10-1AB2 6GK GA00-1AB2 6GK GA10-1AB2 6GK GA00-1AB2 6GK GA10-1AB2 Further documentation The "SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks" manual contains additional information on other SIMATIC NET products that you can operate along with the IE switches of the product line in an Industrial Ethernet network. You can order the manual "SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks", release 05/2001, using the following order numbers: 6GK1970-1BA10-0AA0 German 6GK1970-1BA10-0AA1 English 6GK1970-1BA10-0AA2 French 6GK1970-1BA10-0AA4 Italian You will also find this network manual on the Internet pages of Service & Support under the following entry ID: ( Operating Instructions, 02/2017, A2B

6 Introduction 1.1 On the Operating Instructions You will find further information in the "System Manual Industrial Ethernet" in the Manual Collection. You will find further information on the SCALANCE system on the Internet at ( Audience These Operating Instructions are intended for persons who commission networks with the IE switches of the product line. SIMATIC NET glossary Explanations of many of the specialist terms used in this documentation can be found in the SIMATIC NET glossary. You will find the SIMATIC NET glossary on the Internet at the following address: ( Security information Siemens provides products and solutions with industrial security functions that support the secure operation of plants, systems, machines and networks. In order to protect plants, systems, machines and networks against cyber threats, it is necessary to implement and continuously maintain a holistic, state-of-the-art industrial security concept. Siemens products and solutions only form one element of such a concept. Customer is responsible to prevent unauthorized access to its plants, systems, machines and networks. Systems, machines and components should only be connected to the enterprise network or the internet if and to the extent necessary and with appropriate security measures (e.g. use of firewalls and network segmentation) in place. Additionally, Siemens guidance on appropriate security measures should be taken into account. For more information about industrial security, please visit ( Siemens products and solutions undergo continuous development to make them more secure. Siemens strongly recommends to apply product updates as soon as available and to always use the latest product versions. Use of product versions that are no longer supported, and failure to apply latest updates may increase customer s exposure to cyber threats. To stay informed about product updates, subscribe to the Siemens Industrial Security RSS Feed under ( Trademarks The following and possibly other names not identified by the registered trademark sign are registered trademarks of Siemens AG: SIMATIC NET, SCALANCE, C-PLUG, OLM 6 Operating Instructions, 02/2017, A2B

7 Introduction 1.2 On the product 1.2 On the product What is possible? The IE switches of the product line allow the cost-effective installation of Industrial Ethernet bus and star structures with switching functionality. With the following IE switches, there are also electrical/optical media transitions: SCALANCE XB004-1 SCALANCE XB004-2 SCALANCE XB004-1LD SCALANCE XB004-1G SCALANCE XB004-1LDG Note It is not possible to use IE switches of the product line in a redundant ring because they do not support redundancy. Note If devices are supplied over long 24 V power supply lines or networks, measures are necessary to prevent interference by strong electromagnetic pulses on the supply lines. These can result, for example, due to lightning or switching of large inductive loads. One of the tests used to attest the immunity of these devices to electromagnetic interference is the "surge immunity test" according to EN This test requires overvoltage protection for the power supply lines. A suitable device is, for example, the Dehn Blitzductor BVT AVD 24 V type no or a comparable protective element. For AC operation, for example the blitzductor BVT ALD 60 Art. no or a comparable protective element is suitable. Manufacturer: DEHN+SÖHNE GmbH+Co.KG Hans Dehn Str.1 Postfach 1640 D Neumarkt, Germany Components of the product The following components are supplied with a : IE switch 3-pin terminal block (power supply) Product information Operating Instructions, 02/2017, A2B

8 Introduction 1.2 On the product Accessories Component Length Packaging unit IE TP Cord RJ-45/RJ-45, CAT 6, TP cable 4x2, fitted with 2 RJ-45 plugs IE TP Cord RJ-45/RJ-45, CAT 6, TP cable 4x2, fitted with 2 RJ-45 plugs IE TP Cord RJ-45/RJ-45, CAT 6, TP cable 4x2, fitted with 2 RJ-45 plugs IE TP Cord RJ-45/RJ-45, CAT 6, TP cable 4x2, fitted with 2 RJ-45 plugs IE TP Cord RJ-45/RJ-45, CAT 6, TP cable 4x2, fitted with 2 RJ-45 plugs Order number Suitable for XB-000 Fast Ethernet Suitable for XB-000G Gigabit Ethernet 0.5 m 1 6XV1870-3QE m 1 6XV1870-3QH m 1 6XV1870-3QH m 1 6XV1870-3QH m 1 6XV1870-3QN IE FC Stripping Tool - 1 6GK1901-1GA IE FC blade cassettes (5 mm) - 1 6GK1901-1GB IE FC TP standard cable GP 2x2-1 6XV1840-2AH IE FC TP standard cable GP 4x2-1 6XV1878-2A (+) + IE FC TP trailing cable - 1 6XV1840-3AH IE FC TP marine cable - 1 6XV1840-4AH IE FC TP trailing cable GP - 1 6XV1870-2D + - IE FC TP flexible cable GP 2x2-1 6XV1870-2B + - IE FC TP flexible cable GP 4x2-1 6XV1878-2B (+) + IE FC TP FRNC cable GP - 1 6XV1871-2F + - IE FC TP festoon cable GP - 1 6XV1871-2S + - IE FC TP food cable - 1 6XV1871-2L + - IE TP torsion cable - 1 6XV1870-2F + - FO standard cable 50/125, fitted with 2x2 SC connectors, pulling aid FO standard cable 50/125, fitted with 2x2 SC connectors, pulling aid FO standard cable 50/125, fitted with 2x2 SC connectors, pulling aid FO standard cable 50/125, fitted with 2x2 SC connectors, pulling aid FO standard cable 50/125, fitted with 2x2 SC connectors, pulling aid 80 m 1 6XV1873-6AN m 1 6XV1873-6AT m 1 6XV1873-6AT m 1 6XV1873-6AT m 1 6XV1873-6AT FO standard cable GP (50/125) - 1 6XV1873-2A + + FO trailing cable (50/125) - 1 6XV1873-2C + + FO trailing cable GP (50/125) - 1 6XV1873-2D + + FO ground cable (50/125) - 1 6XV1873-2G Operating Instructions, 02/2017, A2B

9 Introduction 1.2 On the product Component Length Packaging unit Order number Suitable for XB-000 Fast Ethernet Suitable for XB-000G Gigabit Ethernet FO FRNC cable (50/125) - 1 6XV1873-2B + + IE FC RJ-45 Plug 180 2x2-1 6GK1901-1BB10-2AA0 + - IE FC RJ-45 Plug 4x2-1 6GK1901-1BB11-2AA0 (+) + IE FC RJ-45 Plug 180 2x2-10 6GK1901-1BB10-2AB0 + - IE FC RJ-45 Plug 4x2-10 6GK1901-1BB11-2AB0 (+) + IE FC RJ-45 Plug 180 2x2-50 6GK1901-1BB10-2AE0 + - IE FC RJ-45 Plug 4x2-50 6GK1901-1BB11-2AE0 (+) + Note For the devices with Fast Ethernet, you can use cables and connectors with 2x2 lines. The use of 4x2 lines is also possible but not absolutely necessary. These products are indicated by (+). Unpacking and checking WARNING Do not use any parts that show evidence of damage If you use damaged parts, there is no guarantee that the device will function according to the specification. If you use damaged parts, this can lead to the following problems: Injury to persons Loss of the approvals Violation of the EMC regulations Damage to the device and other components Use only undamaged parts. 1. Make sure that the package is complete. 2. Check all the parts for transport damage. Recycling and disposal The products are low in pollutants, can be recycled and meet the requirements of the WEEE directive 2012/19/EU for the disposal of electrical and electronic equipment. Do not dispose of the products at public disposal sites. For environmentally friendly recycling and the disposal of your old device contact a certified disposal company for electronic scrap or your Siemens contact (Product return ( Note the different national regulations. Operating Instructions, 02/2017, A2B

10 Introduction 1.2 On the product Electrostatic discharge NOTICE Electrostatic sensitive devices (ESD) Electronic modules contain electrostatic sensitive components These components can easily be destroyed if handled incorrectly. Note the following instructions to avoid damage. Touch electronic modules only when you absolutely need to work on them. If electronic modules need to be touched, the body of the person involved must first be electrostatically discharged and grounded. Do not bring electronic modules in contact with electrically isolating materials such as plastic film, isolating table top pads or clothing made of synthetic fibers. Place the modules only on conductive surfaces. Pack, store and transport electronic modules and components only in conductive packaging such as metalized plastic or metal containers, conductive foam or household aluminum foil. 10 Operating Instructions, 02/2017, A2B

11 Safety notices 2 Read the safety notices Note the following safety notices. These relate to the entire working life of the device. You should also read the safety notices relating to handling in the individual sections, particularly in the sections "Installation" and "Connecting up". Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not open the device when the supply voltage is turned on. Safety notices when using the device according to Hazardous Locations (HazLoc) and FM. If you use the device under HazLoc or FM conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or nonhazardous locations only. This equipment is suitable for use in Class I, Zone 2, Group IIC or non-hazardous locations only. Operating Instructions, 02/2017, A2B

12 Safety notices 12 Operating Instructions, 02/2017, A2B

13 Network topologies 3 Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion. Which topologies can be implemented? Using the IE switches of the product line, you can implement star topologies. Note Keep to the maximum permitted cable lengths of the devices you are using. You will find the permitted cable lengths in the section "Technical specifications (Page 53)". Star topology Figure 3-1 Example of an electrical star topology with SCALANCE XB005 Operating Instructions, 02/2017, A2B

14 Network topologies Figure 3-2 Example of an electrical/optical star topology with SCALANCE XB Operating Instructions, 02/2017, A2B

15 Description of the device overview Table 4-1 Overview of the product characteristics SIMATIC environment XB004-1 XB004-2 XB004-1LD XB005 XB008 XB004-1G XB004-1LDG XB005 G XB008G Diagnostics LED VDC VAC + 1) - + 1) + 1) x 24 VDC Signaling contact + on-site operation Diagnostics: Web, SNMP, PROFINET C-PLUG Ring redundancy with RM Passive ring redundancy Standby redundancy IRT capability Fast learning Passive listening Log table SNTP + SICLOCK Cut Through ) Note the Hardware version (Page 53). Operating Instructions, 02/2017, A2B

16 Description of the device 4.1 overview Table 4-2 Overview of the connection options TP (RJ-45) Fast Ethernet 10 / 100 Mbps Fiber multimode (SC) Fast Ethernet 100 Mbps Single-mode fiber (SC) Fast Ethernet 100 Mbps TP (RJ-45) Gigabit Ethernet 10 / 100 / 1000 Mbps Fiber multimode (SC) Gigabit Ethernet 1000 Mbps Fiber single mode (SC) Gigabit Ethernet 1000 Mbps XB004-1 XB004-2 XB004-1LD XB005 XB008 XB004-1G XB004-1LDG XB005G XB008G Operating Instructions, 02/2017, A2B

17 Description of the device 4.2 Product characteristics 4.2 Product characteristics SCALANCE XB004-1 Possible attachments The SCALANCE XB004-1 has four RJ-45 jacks and an SC socket for the connection of end devices or other network segments. Figure 4-1 SCALANCE XB004-1 Operating Instructions, 02/2017, A2B

18 Description of the device 4.2 Product characteristics SCALANCE XB004-2 Possible attachments The SCALANCE XB004-2 has four RJ-45 jacks and two SC sockets for the connection of end devices or other network segments. Figure 4-2 SCALANCE XB Operating Instructions, 02/2017, A2B

19 Description of the device 4.2 Product characteristics SCALANCE XB004-1LD Possible attachments The SCALANCE XB004-1LD has four RJ-45 jacks and an SC socket for the connection of end devices or other network segments. Figure 4-3 SCALANCE XB004-1LD Operating Instructions, 02/2017, A2B

20 Description of the device 4.2 Product characteristics SCALANCE XB005 Possible connections The SCALANCE XB005 has five RJ-45 jacks for connection of end devices or other network segments. Figure 4-4 SCALANCE XB Operating Instructions, 02/2017, A2B

21 Description of the device 4.2 Product characteristics SCALANCE XB008 Possible connections The SCALANCE XB008 has eight RJ-45 jacks for the connection of end devices or other network segments. Figure 4-5 SCALANCE XB008 Operating Instructions, 02/2017, A2B

22 Description of the device 4.2 Product characteristics SCALANCE XB004-1G Possible attachments The SCALANCE XB004-1G has four RJ-45 jacks capable of Gigabit and an SC socket for the connection of end devices or other network segments. Figure 4-6 SCALANCE XB004-1G 22 Operating Instructions, 02/2017, A2B

23 Description of the device 4.2 Product characteristics SCALANCE XB004-1LDG Possible attachments The SCALANCE XB004-1LDG has four RJ-45 jacks capable of Gigabit and an SC socket for the connection of end devices or other network segments. Figure 4-7 SCALANCE XB004-1LDG Operating Instructions, 02/2017, A2B

24 Description of the device 4.2 Product characteristics SCALANCE XB005G Possible attachments The SCALANCE XB005G has five RJ-45 jacks capable of Gigabit for connection of end devices or other network segments. Figure 4-8 SCALANCE XB005G 24 Operating Instructions, 02/2017, A2B

25 Description of the device 4.2 Product characteristics SCALANCE XB008G Possible attachments The SCALANCE XB008G has eight RJ-45 jacks capable of Gigabit for the connection of end devices or other network segments. Figure 4-9 SCALANCE XB008G Operating Instructions, 02/2017, A2B

26 Description of the device 4.3 TP ports (twisted pair) 4.3 TP ports (twisted pair) Note Strain relief of the interfaces To prevent weights or mechanical movement that can affect an interface causing interrupted contact, fix the cables to a cable guide or rail at short intervals Pin assignment With IE switches of the product line, the twisted-pair ports are designed as RJ-45 jacks with MDI-X pin assignment (Medium Dependent Interface Autocrossover) of a network component. Pin number Assignment for Assignment for G Pin 8 n. c. D4- Pin 7 n. c. D4+ Pin 6 TD- D2- Pin 5 n. c. D3- Pin 4 n. c. D3+ Pin 3 TD+ D2+ Pin 2 RD- D1- Pin 1 RD+ D1+ Note TP cords or TP-XP cords with a maximum length of 10 m can be connected to the TP port with the RJ-45 jack. With the IE FC cables and IE FC RJ-45 plug 180, an overall cable length of a maximum of 100 m is permitted between two devices depending on the cable type. 26 Operating Instructions, 02/2017, A2B

27 Description of the device 4.3 TP ports (twisted pair) Functions Autonegotiation With the autonegotiation mechanism, repeaters and end devices can automatically determine the transmission speed and the transmission mode of the partner port. This makes it possible to configure different devices automatically. Two components connected to a link segment can exchange information about the data transfer and can adapt their settings to each other. The mode with the highest possible speed is set. Note Devices not supporting autonegotiation must be set to 1000 Mbps/ half duplex, 100 Mbps/ half duplex or 10 Mbps half duplex. Note The IE switches of the product line are plug-and-play devices that require no settings during commissioning. Auto polarity exchange If the pair of receiving cables is connected incorrectly (RD+ and RD- interchanged), the polarity is adapted automatically. MDI / MDI-X autocrossover function With the MPI/MDI-X autocrossover function, the send and receive contacts of an Ethernet port are assigned automatically. The assignment depends on the cable with which the communications partner is connected. This means that it does not matter whether the port is connected using a patch cable or crossover cable. This prevents malfunctions resulting from mismatching send and receive lines. This makes installation much easier for the user. The IE switches of the product line all support the MDI/MDIX autocrossover function. Note Please note that the direct connection of two ports on the IE switch or accidental connection over several IE switches causes an illegal loop. Such a loop can lead to network overload and network failures. Operating Instructions, 02/2017, A2B

28 Description of the device 4.3 TP ports (twisted pair) Insulation between the TP ports The insulation between the TP ports is based on the number of TP ports. The SCALANCE XB004-1 group includes the following devices: SCALANCE XB004-1 SCALANCE XB004-1LD SCALANCE XB004-1G SCALANCE XB004-1LDG The SCALANCEXB004-2 group includes the following devices: SCALANCE XB004-2 The SCALANCE XB005 group includes the following devices: SCALANCE XB005 SCALANCE XB005G The SCALANCE XB008 group includes the following devices: SCALANCE XB008 SCALANCE XB008G SCALANCE XB004-1 There are two TP port groups: Group1: P1 and P4 Group2: P2 and P5 Between ports of different port groups, an insulation voltage of 1.5 kv is adhered to (corresponds to IEEE802.3, Chapter , Environment B), e.g. between P1 and P2. The requirements for Environment A are met between ports of the same group, e.g. between P1 and P4. SCALANCE XB004-2 There are two TP port groups: Group1: P2 and P5 Group2: P3 and P6 Between ports of different port groups, an insulation voltage of 1.5 kv is adhered to (corresponds to IEEE802.3, Chapter , Environment B), e.g. between P2 and P3. The requirements for Environment A are met between ports of the same group, e.g. between P2 and P5. 28 Operating Instructions, 02/2017, A2B

29 Description of the device 4.3 TP ports (twisted pair) SCALANCE XB005 There are three TP port groups: Group1: P1 and P4 Group2: P2 and P5 Group3: P3 Between ports of different port groups, an insulation voltage of 1.5 kv is adhered to (corresponds to IEEE802.3, Chapter , Environment B), e.g. between P1 and P2. The requirements for Environment A are met between ports of the same group, e.g. between P2 and P5. SCALANCE XB008 There are four TP port groups: Group1: P1 and P5 Group2: P2 and P6 Group3: P3 and P7 Group4: P4 and P8 Between ports of different port groups, an insulation voltage of 1.5 kv is adhered to (corresponds to IEEE802.3, Chapter , Environment B), e.g. between P2 and P4. The requirements for Environment A are met between ports of the same group, e.g. between P1 and P5. Operating Instructions, 02/2017, A2B

30 Description of the device 4.4 FO port (fiber optic) 4.4 FO port (fiber optic) NOTICE Failure of the data traffic due to contamination of optical plug-in connections Optical sockets and plugs are sensitive to contamination of the end face. Contamination can lead to the failure of the optical transmission network. Close unused optical sockets and plugs as well as pluggable transceivers and slots with the supplied protective caps. Remove the protective caps only immediately before you use the plug-in connection SCALANCE XB004-1 Transmission rate The transmission rate of the optical Fast Ethernet port is 100 Mbps. Transmission mode The transmission mode for 100Base-FX is specified in the IEEE standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used. Transmission medium Data transmission is over multimode fiber-optic cable (FOC). The wavelength is 1310 nm. The FO cables are compatible with multimode FO cables with 1300 nm. Multimode fiber-optic cables are used with a core of 50 or 62.5 µm; the light source is an LED. The outer diameter of the FOC is 125 µm. Range The maximum transmission range (segment length) with a signal attenuation of the fiberoptic cable of 1 db/km at 1310 nm is: with 62.5/125 µm fiber multimode SIMATIC NET cable: 4 km with 50.0/125 µm fiber multimode SIMATIC NET cable: 5 km Connectors The cables are connected to SC sockets. 30 Operating Instructions, 02/2017, A2B

31 Description of the device 4.4 FO port (fiber optic) SCALANCE XB004-2 Transmission rate The transmission speed of the optical Fast Ethernet ports is 100 Mbps. Transmission mode The transmission mode for 100Base-FX is specified in the IEEE standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used. Transmission medium Data transmission is over multimode fiber-optic cable (FOC). The wavelength is 1310 nm. The FO cables are compatible with multimode FO cables with 1300 nm. Multimode fiber-optic cables are used with a core of 50 or 62.5 µm; the light source is an LED. The outer diameter of the FOC is 125 µm. Range The maximum transmission range (segment length) with a signal attenuation of the fiberoptic cable of 1 db/km at 1310 nm is: with 62.5/125 µm fiber multimode SIMATIC NET cable: 4 km with 50.0/125 µm fiber multimode SIMATIC NET cable: 5 km Connectors The cables are connected to SC sockets SCALANCE XB004-1LD Transmission rate The transmission rate of the optical Fast Ethernet port is 100 Mbps. Transmission mode The transmission mode for 100Base-LX is specified in the IEEE standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used. Operating Instructions, 02/2017, A2B

32 Description of the device 4.4 FO port (fiber optic) Transmission medium Data transmission is over single-mode fiber-optic cable (FO cable). The transceiver wavelength is 1310 nm. The FO cables are compatible with single-mode FO cables with 1300 nm. Single-mode fiber-optic cable with a core diameter of 10 µm is used. The outer diameter of the FOC is 125 µm. Sender The light source is an "eye safe" class 1 laser with a wavelength of 1310 nm. Range The maximum transmission range (segment length) is 26 km for a signal attenuation of the fiber-optic cable of 0.5 db/km. Connectors The cables are connected to SC sockets SCALANCE XB004-1G Transmission rate The transmission rate of the optical Fast Ethernet port is 1000 Mbps. Transmission mode The transmission mode for 1000Base-SX is specified in the IEEE 802.3z standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used. Transmission medium Data transmission is over multimode fiber-optic cable (FOC). The wavelength is 850 nm. Multimode fiber-optic cable with a core diameter of 50 µm is used. Fiber-optic cables with a core diameter of 62.5 µm are not recommended for 1000Base-SX because this reduces the maximum segment length drastically. The outer diameter of the FOC is 125 µm. Sender The light source is an "eye safe" class 1 laser with a wavelength of 850 nm (EN ). 32 Operating Instructions, 02/2017, A2B

33 Description of the device 4.4 FO port (fiber optic) Range Depending on the fiber-optic cable used, the maximum transmission range (segment length) is 750 m when using SIMATIC NET fiber-optic multimode cable with SC duplex connectors or 550 m when using a standard multimode FO cable. Connectors The cables are connected to SC sockets SCALANCE XB004-1LDG Transmission rate The transmission rate of the optical Fast Ethernet port is 1000 Mbps. Transmission mode The transmission mode for 1000Base-LH is specified in the IEEE 802.3z standard. Since the full duplex mode and the transmission rate cannot be modified for optical transmission, autonegotiation cannot be used. Transmission medium Data transmission is over single-mode fiber-optic cable (FO cable). The transceiver wavelength is 1310 nm. The FO cables are compatible with single-mode FO cables with 1300 nm. Single-mode fiber-optic cable with a core diameter of 10 µm is used. The outer diameter of the FOC is 125 µm. Sender The light source is an "eye safe" class 1 laser with a wavelength of 1310 nm. Range The maximum transmission range (segment length) is 10 km for a signal attenuation of the fiber-optic cable of 0.5 db/km. Connectors The cables are connected to SC sockets. Operating Instructions, 02/2017, A2B

34 Description of the device 4.5 LEDs 4.5 LEDs Power LED 'L' (green LED) The power LED shows the status of the power supply. LED color LED status Meaning Green Lit Power supply is connected - Off Power supply is not connected or the applied voltage is too low. Refer also to the section "Possible sources of errors and eliminating errors (Page 51)" Port LED 'P' (green LED) The port LEDs indicate the status of the ports. The port LEDs are located directly on the port. LED color LED status Meaning Green Lit Link exists, no data reception at port Green Flashing Link exists, data reception at port Green Flashing / flash on and off in sequence Test phase during power on 34 Operating Instructions, 02/2017, A2B

35 Mounting Safety notices for installation Safety notices When installing the device, keep to the safety notices listed below. WARNING If the device is installed in a cabinet, the inner temperature of the cabinet corresponds to the ambient temperature of the device. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Replacing components may impair suitability for Class 1, Division 2 or Zone 2. WARNING The device is intended for indoor use only. WARNING The device may only be operated in an environment with pollution degree 1 or 2 (see IEC ). WARNING When used in hazardous environments corresponding to Class I, Division 2 or Class I, Zone 2, the device must be installed in a cabinet or a suitable enclosure. Operating Instructions, 02/2017, A2B

36 Mounting 5.1 Safety notices for installation Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING To comply with EC Directive 2014/34/EU (ATEX 114) or the conditions of IECEx, this enclosure or cabinet must meet the requirements of at least IP54 in compliance with EN WARNING If the cable or conduit entry point exceeds 70 C or the branching point of conductors exceeds 80 C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 50 C to 60 C, only use cables with admitted maximum operating temperature of at least 80. Safety notices when using according to FM If you use the device under FM conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING EXPLOSION HAZARD The equipment is intended to be installed within an enclosure/control cabinet. The inner service temperature of the enclosure/control cabinet corresponds to the ambient temperature of the module. Use cables with a maximum permitted operating temperature of at least 20 C higher than the maximum ambient temperature. Safety notices when using the device as industrial control equipment according to UL If you use the device under UL conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING The devices are "open equipment" acc. to the standard UL To fulfill requirements for safe operation with regard to mechanical stability, flame retardation, stability, and protection against contact, the following alternative types of installation are specified: Installation in a suitable cabinet. Installation in a suitable enclosure. Installation in a suitably equipped, enclosed control room. 36 Operating Instructions, 02/2017, A2B

37 Mounting 5.2 Types of installation WARNING If the cable or housing socket exceeds 70 C or the branching point of the cables exceeds 60 C, special precautions must be taken. If the equipment is operated in an air ambient in excess of 40 C, only use cables with admitted maximum operating temperature of at least Types of installation The devices can be installed in the following ways: Installation on a 35 mm DIN rail Wall mounting WARNING If a device is operated in an ambient temperature of more than 50 C to 60 C, the temperature of the device housing may be higher than 70 C. The device must therefore be installed so that it is only accessible to service personnel or users that are aware of the reason for restricted access and the required safety measures at an ambient temperature higher than 60. Installation clearance Keep to the minimum clearances so that the convection ventilation of the device is not blocked. Below at least 10 cm Above at least 10 cm See also SIMATIC NET Industrial Ethernet TP and Fiber Optic Networks ( Operating Instructions, 02/2017, A2B

38 Mounting 5.3 Fixing onto standard mounting rails 5.3 Fixing onto standard mounting rails Mounting To install the device on a 35 mm DIN rail, follow the steps below: 1. Place the housing guide of the device on the top edge of the DIN rail. 2. Push the device down against rail until it locks in place. Figure 5-1 Installation on a 35 mm DIN rail 3. Fit the connectors for the power supply. See also section "Power supply (Page 45)" 4. Insert the terminal block into the sockets on the device. Figure 5-2 mounted on the 35 mm DIN rail 38 Operating Instructions, 02/2017, A2B

39 Mounting 5.3 Fixing onto standard mounting rails Removal To remove the device from the DIN rail, follow the steps below: 1. Disconnect all connected cables. 2. Pull out the terminal block for the power supply. 3. Lever the catch on the underside of the device approximately 5 mm out using a screwdriver 4. Pull the lower part of the device away from the DIN rail. Figure 5-3 Removal from a 35 mm DIN rail Operating Instructions, 02/2017, A2B

40 Mounting 5.4 Wall mounting 5.4 Wall mounting WARNING Wall mounting is only permitted if the requirements for the housing, the installation regulations, the clearance and separating regulations for the control cabinets or housings are adhered to. The control cabinet cover or housing must be secured so that it can only be opened with a tool. An appropriate strain-relief assembly for the cable must be used. WARNING Wall mounting outside of the control cabinet or housing does not fulfill the requirements of the FM approval. Note You must not install the device on a wall in hazardous areas. To mount the device on a wall, you require the following: 2 wall plugs, 6 mm in diameter and 30 mm long 2 washers 2 screws 3.5 mm in diameter and 35 mm long To mount the device on a wall, follow the steps below: Figure 5-4 Preparation for wall mounting 40 Operating Instructions, 02/2017, A2B

41 Mounting 5.4 Wall mounting 1. Push out the two catches on the rear of the device. 2. Prepare the drill holes for wall mounting. For the precise dimensions, refer to the section "Dimension drawings (Page 89)". 3. Fit the connectors for the power supply. See also section "Power supply (Page 45)". 4. Insert the terminal block into the socket on the device. 5. Screw the device to the wall. Figure 5-5 Wall mounting of the Note The wall mounting must be capable of supporting at least four times the weight of the device. Operating Instructions, 02/2017, A2B

42

43 Connecting up Safety when connecting up Safety notices When connecting up the device, keep to the safety notices listed below. WARNING The equipment is designed for operation with Safety Extra-Low Voltage (SELV) by a Limited Power Source (LPS). This means that only SELV / LPS complying with IEC / EN / VDE must be connected to the power supply terminals, or the power supply unit for the equipment power supply must comply with NEC Class 2, as described by the National Electrical Code (r) (ANSI / NFPA 70). If the equipment is connected to a redundant power supply (two separate power supplies), both must meet these requirements. Safety notices on use in hazardous areas General safety notices relating to protection against explosion WARNING EXPLOSION HAZARD Do not connect or disconnect cables to or from the device when a flammable or combustible atmosphere is present. Safety notices when using the device according to Hazardous Locations (HazLoc) and FM. If you use the device under HazLoc or FM conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING EXPLOSION HAZARD Do not connect or disconnect while the circuit is live or unless the area is known to be free of ignitible concentrations. Operating Instructions, 02/2017, A2B

44 Connecting up 6.2 Wiring rules Safety notices for use according to ATEX and IECEx If you use the device under ATEX or IECEx conditions you must also keep to the following safety notices in addition to the general safety notices for protection against explosion: WARNING Take measures to prevent transient voltage surges of more than 40% of the rated voltage. This is the case if you only operate devices with SELV (safety extra-low voltage). 6.2 Wiring rules When wiring use cables with the following AWG categories or cross sections. Wiring rules for... connectable cable cross sections for flexible cables... Screw/spring-loaded terminals without wire end ferrule mm 2 with wire end ferrule with plastic ferrule** with wire end ferrule without plastic ferrule** AWG: mm 2 AWG: mm 2 AWG: with TWIN wire end ferrule** mm 2 AWG: Stripped length of the cable 8-10 mm Wire end ferrule according to DIN with plastic ferrule** 8-10 mm * AWG: American Wire Gauge ** See note "Wire end ferrules" Note Wire end ferrules Use crimp shapes with smooth surfaces, such as provided by square and trapeze shaped crimp cross sections. Crimp shapes with wave-shaped profile are unsuitable. 44 Operating Instructions, 02/2017, A2B

45 Connecting up 6.3 Power supply 6.3 Power supply The power supply is connected via a plug-in terminal block with three terminals on the underside of the. The functional ground can be connected to the grounded DIN rail. It does not need to be connected for problem-free operation. The power supply is non-floating. Note The device can be disconnected from the power supply by removing the terminal block. Note The devices correspond to overvoltage category I Power supply 24 VAC You can operate the following devices as of a certain hardware version (Page 53) with a 24 VAC power supply XB004-1 XB004-1LD XB005 The following figure shows the position of the power supply and the assignment of the terminal block. Pin number Pin 1 Pin 2 Pin 3 Assignment Functional ground M (24 VAC, 50/60 Hz) L+ (24 VAC, 50/60 Hz) Operating Instructions, 02/2017, A2B

46 Connecting up 6.3 Power supply WARNING Incorrect power supply The power supply unit for supplying the devices must comply with NEC Class 2 or LPS (voltage range V, current requirements 350 ma). Do not operate the devices with AC voltages higher than 28.8 VAC Power supply 24 VDC You can operate the following devices with a 24 VDC power supply XB004-1 XB004-2 XB004-1LD XB005 XB008 XB004-1G XB004-1LDG XB005G XB008G The following figure shows the position of the power supply and the assignment of the terminal block. Pin number Pin 1 Pin 2 Pin 3 Assignment Functional ground M (chassis ground) L+ (24 VDC) 46 Operating Instructions, 02/2017, A2B

47 Connecting up 6.4 Grounding WARNING Incorrect power supply The power supply unit for supplying the devices must comply with NEC Class 2 or LPS (voltage range V, current requirements 350 ma). Do not operate the devices with DC voltages higher than 28.8 VDC. Do not operate the device with an AC voltage: XB008 XB004-1G XB004-1LDG XB005G XB008G 6.4 Grounding A functional grounding can be established by connecting a cable from terminal 1 to the DIN rail,, for example. Such a cable should be kept as short as possible. Grounding is, however, not necessary for operation. 6.5 Twisted pair cable Recommendation Cable quality at least CAT 5 Standard cables and IE FC RJ-45 Plug 180 connectors that can be assembled in the field for connection to the LAN over greater distances. To connect the device over a short distance, preassembled cables e.g. TP Cord RJ m Operating Instructions, 02/2017, A2B

48 Connecting up 6.6 IE FC RJ-45 Plug IE FC RJ-45 Plug 180 The rugged node connectors are designed for industry with PROFINET-compliant connectors and provide additional strain and bending relief with a locking mechanism on the casing. Fitting the IE FC RJ45 Plug 180 to the IE FC Standard Cable You will find the notes on installation in the instructions that ship with the IE FC RJ45 Plug 180. Figure 6-1 IE FC 45 Plug 180 Plugging in the IE FC RJ45 Plug 180 Plug the IE FC RJ45 Plug 180 into the twisted-pair port of the device until it locks in place. Figure 6-2 Plugging in the IE FC RJ45 Plug 180 When using Ethernet cables with IE FastConnect RJ-45 plugs on devices without securing collars, the cables must be supported on a cable guide close to the device. 48 Operating Instructions, 02/2017, A2B

49 Connecting up 6.6 IE FC RJ-45 Plug 180 Pulling the IE FC RJ45 Plug 180 Press on the locking lever of the IE FC RJ45 Plug 180 gently to remove the plug. If there is not enough space to release the lock with your hand, you can also use a 2.5 mm screwdriver. You can then remove the IE FC RJ45 Plug 180 from the RJ-45 jack. Operating Instructions, 02/2017, A2B

50

51 Maintenance and troubleshooting Possible sources of problems and how to deal with them Fuses The IE switches of the product line have a resettable fuse / PTC. If the fuse triggers (all LEDs are off despite correctly applied power supply), the device should be disconnected from the power supply for approximately 30 minutes before turning it on again. LED display when voltage is too low If the power supply is too low, then the internal power supply will switch off causing the Power LED and all port LEDs to go off. The functionality of the is no longer available. A power supply of at least 19.2 V is necessary for correct operation. Device defective If a fault develops, please send the device to your SIEMENS service center for repair. Repairs on-site are not possible. Operating Instructions, 02/2017, A2B

52 Maintenance and troubleshooting 7.1 Possible sources of problems and how to deal with them 52 Operating Instructions, 02/2017, A2B

53 Technical specifications SCALANCE XB004-1 Table 8-1 Technical specifications of the SCALANCE XB004-1 Technical specifications Article number SCALANCE XB004-1 Attachment to Industrial Ethernet Quantity 4 Design Properties Transmission rate Optical connectors Quantity 1 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK BD00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10/100 Mbps SC socket Full duplex acc. to 100Base-FX 100 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180 Max. 45 m IE TP Torsion Cable with IE FC RJ m TP Cord via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180 Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180 Optical parameters Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet Cable type Permitted cable length (glass FO cable) Multimode glass FO cable, cable cross sections 62.5/125 μm and 50/125 μm Cable cross-section Permitted cable length 62.5/125 μm 0 to 4,000 m 50/125 μm 0 to 5,000 m Operating Instructions, 02/2017, A2B

54 Technical specifications 8.1 SCALANCE XB004-1 Technical specifications Electrical data Power supply Rated voltage 24 VAC, 50/60 Hz 1) Voltage range Design 24 VDC Current consumption Typically, 24 VAC 230 ma Typically 24 VDC 19.2 to 28.8 VAC/VDC Safety Extra Low Voltage (SELV) 3-terminal plug-in block 105 ma Effective power loss Typically, 24 VAC 5.5 VA Typically 24 VDC 2.5 W Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 165 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Wall mounting Aging time 300 seconds / 45 seconds 1) 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q 1024 Blocking Forwarding Yes 54 Operating Instructions, 02/2017, A2B

55 Technical specifications 8.1 SCALANCE XB004-1 Technical specifications QoS priority queues 2 / 4 1) IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Yes 1) as of hardware version 4 Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. Hardware version You will find the hardware version of your device on the type plate. On the type plate, the hardware version is printed as a placeholder X. Example: X In this case, "X" would be the placeholder for hardware version 1. Operating Instructions, 02/2017, A2B

56 Technical specifications 8.2 SCALANCE XB SCALANCE XB004-2 Table 8-2 Technical specifications of the SCALANCE XB004-2 Technical specifications Article number SCALANCE XB004-2 Attachment to Industrial Ethernet Quantity 4 Design Properties Transmission rate Optical connectors Quantity 2 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) RJ-45 jacks with MDI-X pinning Half / full duplex 10/100 Mbps SC socket Full duplex acc. to 100Base-FX 100 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180 Max. 45 m IE TP Torsion Cable with IE FC RJ m TP Cord via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180 Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180 Optical parameters Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet Cable type Permitted cable length (glass FO cable) Multimode glass FO cable, cable cross sections 62.5/125 μm and 50/125 μm Cable cross-section Permitted cable length 62.5/125 μm 0 to 4,000 m 50/125 μm 0 to 5,000 m Electrical data Power supply Rated voltage 24 VDC Voltage range 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) Design 3-terminal plug-in block Current consumption Typically 24 VDC 165 ma Effective power loss Typically 24 VDC 4 W Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V) 56 Operating Instructions, 02/2017, A2B

57 Technical specifications 8.2 SCALANCE XB004-2 Technical specifications Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 205 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses 1024 Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q QoS priority queues 4 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Wall mounting 45 seconds Blocking Forwarding Yes Yes 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. Operating Instructions, 02/2017, A2B

58 Technical specifications 8.3 SCALANCE XB004-1LD 8.3 SCALANCE XB004-1LD Table 8-3 Technical specifications of the SCALANCE XB004-1LD Technical specifications Article number SCALANCE XB004-1LD Attachment to Industrial Ethernet Quantity 4 Design Properties Transmission rate Optical connectors Quantity 1 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK BF00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10/100 Mbps SC sockets Full duplex acc. to 100Base-LX 100 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180 Max. 45 m IE TP Torsion Cable with IE FC RJ m TP Cord via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180 Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180 Optical parameters Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet Cable type Cable cross-section Permitted cable length Attenuation Electrical data Single mode glass FO cable 10/125 μm 0 to 26,000 m 0.5 db/km at 1310 nm 13 db max. permitted FO cable attenuation with 2 db link power margin Power supply Rated voltage 24 VAC, 50/60 Hz 1) 24 VDC Voltage range Design 19.2 to 28.8 VAC/VDC Safety Extra Low Voltage (SELV) 3-terminal plug-in block 58 Operating Instructions, 02/2017, A2B

59 Technical specifications 8.3 SCALANCE XB004-1LD Technical specifications Current consumption Typically, 24 VAC 210 ma Typically 24 VDC 95 ma Effective power loss Typically, 24 VAC 5.1 VA Typically 24 VDC 2.3 W Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 165 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Wall mounting Aging time 300 seconds / 45 seconds 1) 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q 1024 Blocking Forwarding Yes QoS priority queues 2 / 4 1) IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Yes 1) as of hardware version 4 Operating Instructions, 02/2017, A2B

60 Technical specifications 8.3 SCALANCE XB004-1LD Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. Hardware version You will find the hardware version of your device on the type plate. On the type plate, the hardware version is printed as a placeholder X. Example: X In this case, "X" would be the placeholder for hardware version Operating Instructions, 02/2017, A2B

61 Technical specifications 8.4 SCALANCE XB SCALANCE XB005 Table 8-4 Technical specifications of the SCALANCE XB005 Technical specifications Article number SCALANCE XB005 Attachment to Industrial Ethernet Quantity 5 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK BA00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10/100 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180 Max. 45 m IE TP Torsion Cable with IE FC RJ m TP Cord via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180 Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180 Electrical data Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet Power supply Rated voltage 24 VAC, 50/60 Hz 1) Voltage range Design 24 VDC Current consumption Typically, 24 VAC 150 ma Typically 24 VDC 19.2 to 28.8 VAC/VDC Safety Extra Low Voltage (SELV) 3-terminal plug-in block 65 ma Effective power loss Typically, 24 VAC 3.6 VA Typically 24 VDC 1.6 W Overvoltage protection at input PTC resettable fuse (0.5 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating Instructions, 02/2017, A2B

62 Technical specifications 8.4 SCALANCE XB005 Technical specifications Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 165 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Wall mounting Aging time 300 seconds / 45 seconds 1) 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q 1024 Blocking Forwarding Yes QoS priority queues 2 / 4 1) IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Yes 1) as of hardware version 5 Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. 62 Operating Instructions, 02/2017, A2B

63 Technical specifications 8.5 SCALANCE XB008 Hardware version You will find the hardware version of your device on the type plate. On the type plate, the hardware version is printed as a placeholder X. Example: X In this case, "X" would be the placeholder for hardware version SCALANCE XB008 Table 8-5 Technical specifications of the SCALANCE XB008 Technical specifications Article number SCALANCE XB008 Attachment to Industrial Ethernet Quantity 8 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK BA00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10/100 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable with IE FC RJ45 Plug 180 Max. 45 m IE TP Torsion Cable with IE FC RJ m TP Cord via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable with IE FC RJ45 Plug 180 Max. 75 m IE FC TP Marine/Trailing Cable + 10 m TP Cord via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable with IE FC RJ45 Plug 180 Electrical data Max. 90 m IE FC TP Standard Cable + 10 m TP Cord via IE FC RJ45 Outlet Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 150 ma Power loss at 24 VDC Typical 3.40 W 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block Overvoltage protection at input PTC resettable fuse (0.6 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Operating Instructions, 02/2017, A2B

64 Technical specifications 8.5 SCALANCE XB008 Technical specifications Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 180 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q QoS priority queues 2 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Wall mounting 300 seconds 1024 Blocking Forwarding Yes Yes 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. 64 Operating Instructions, 02/2017, A2B

65 Technical specifications 8.6 SCALANCE XB004-1G 8.6 SCALANCE XB004-1G Note Note the article number in the technical specifications. Table 8-6 Technical specifications of the SCALANCE XB004-1G (6GK GL00-1AB2) Technical specifications Article number SCALANCE XB004-1G Attachment to Industrial Ethernet Quantity 4 Design Properties Transmission rate Optical connectors Quantity 1 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GL00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps SC socket Full duplex acc. to 1000Base-SX 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Optical parameters Cable type Cable cross-section Permitted cable length Electrical data Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet Multimode glass FO cable 50/125 μm 0 to 750 m Power supply Rated voltage 24 VDC Voltage range Design 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block Operating Instructions, 02/2017, A2B

66 Technical specifications 8.6 SCALANCE XB004-1G Technical specifications Current consumption Typical 650 ma Power loss at 24 VDC Typical 15.6 W Overvoltage category CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 210 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q QoS priority queues 4 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Wall mounting 300 seconds 8192 Blocking Forwarding Yes Yes 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature 66 Operating Instructions, 02/2017, A2B

67 Technical specifications 8.6 SCALANCE XB004-1G Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. Table 8-7 Technical specifications of the SCALANCE XB004-1G (6GK GL10-1AB2) Technical specifications Article number SCALANCE XB004-1G Attachment to Industrial Ethernet Quantity 4 Design Properties Transmission rate Optical connectors Quantity 1 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GL10-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps SC socket Full duplex acc. to 1000Base-SX 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Optical parameters Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet Cable type Cable cross-section Permitted cable length Multimode glass FO cable 50/125 μm 0 to 750 m Operating Instructions, 02/2017, A2B

68 Technical specifications 8.6 SCALANCE XB004-1G Technical specifications Electrical data Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 155 ma Power loss at 24 VDC Typical 3.7 W Overvoltage category 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 210 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q QoS priority queues 8 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Wall mounting 45 seconds Blocking Forwarding Yes Yes 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature 68 Operating Instructions, 02/2017, A2B

69 Technical specifications 8.7 SCALANCE XB004-1LDG Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. 8.7 SCALANCE XB004-1LDG Note Note the article number in the technical specifications. Table 8-8 Technical specifications of the SCALANCE XB004-1LDG (6GK GM00-1AB2) Technical specifications Article number SCALANCE XB004-1LDG Attachment to Industrial Ethernet Quantity 4 Design Properties Transmission rate Optical connectors Quantity 1 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GM00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps SC sockets Full duplex acc. to 1000Base-LH 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet Operating Instructions, 02/2017, A2B

70 Technical specifications 8.7 SCALANCE XB004-1LDG Technical specifications 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Optical parameters Cable type Cable cross-section Permitted cable length Attenuation Electrical data Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet Single mode glass FO cable 10/125 μm 0 to 10,000 m 0.5 db/km at 1310 nm 13 db max. permitted FO cable attenuation with 2 db link power margin Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 650 ma Power loss at 24 VDC Typical 15.6 W Overvoltage category 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 210 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Wall mounting 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Aging time 300 seconds 70 Operating Instructions, 02/2017, A2B

71 Technical specifications 8.7 SCALANCE XB004-1LDG Technical specifications Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q QoS priority queues 4 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding 8192 Blocking Forwarding Yes Yes Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. Operating Instructions, 02/2017, A2B

72 Technical specifications 8.7 SCALANCE XB004-1LDG Table 8-9 Technical specifications of the SCALANCE XB004-1LDG (6GK GM10-1AB2) Technical specifications Article number SCALANCE XB004-1LDG Attachment to Industrial Ethernet Quantity 4 Design Properties Transmission rate Optical connectors Quantity 1 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GM10-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps SC sockets Full duplex acc. to 1000Base-LH 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Optical parameters Cable type Cable cross-section Permitted cable length Attenuation Electrical data Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet Single mode glass FO cable 10/125 μm 0 to 10,000 m 0.5 db/km at 1310 nm 13 db max. permitted FO cable attenuation with 2 db link power margin Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 155 ma Power loss at 24 VDC Typical 3.7 W Overvoltage category 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) 72 Operating Instructions, 02/2017, A2B

73 Technical specifications 8.7 SCALANCE XB004-1LDG Technical specifications Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 168 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q Yes QoS priority queues 8 IEEE 802.1Q tags (VLAN ID, priority) Yes transparent forwarding Wall mounting 45 seconds Blocking Forwarding 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Operating Instructions, 02/2017, A2B

74 Technical specifications 8.8 SCALANCE XB005G Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. 8.8 SCALANCE XB005G Note Note the article number in the technical specifications. Table 8-10 Technical specifications of the SCALANCE XB005G (6GK GA00-1AB2) Technical specifications Article number SCALANCE XB005G Attachment to Industrial Ethernet Quantity 5 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GA00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 74 Operating Instructions, 02/2017, A2B

75 Technical specifications 8.8 SCALANCE XB005G Technical specifications Electrical data Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 550 ma Power loss at 24 VDC Typical 13.2 W Overvoltage category 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 220 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q QoS priority queues 4 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Wall mounting 300 seconds 8192 Blocking Forwarding Yes Yes 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Operating Instructions, 02/2017, A2B

76 Technical specifications 8.8 SCALANCE XB005G Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. Table 8-11 Technical specifications of the SCALANCE XB005G (6GK GA10-1AB2) Technical specifications Article number SCALANCE XB005G Attachment to Industrial Ethernet Quantity 5 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GA10-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Electrical data Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 140 ma Power loss at 24 VDC Typical 3.4 W Overvoltage category 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) 76 Operating Instructions, 02/2017, A2B

77 Technical specifications 8.8 SCALANCE XB005G Technical specifications Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 172 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q Yes QoS priority queues 8 IEEE 802.1Q tags (VLAN ID, priority) Yes transparent forwarding Wall mounting 45 seconds Blocking Forwarding 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Operating Instructions, 02/2017, A2B

78 Technical specifications 8.9 SCALANCE XB008G Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. 8.9 SCALANCE XB008G Note Note the article number in the technical specifications. Table 8-12 Technical specifications of the SCALANCE XB008G (6GK GA00-1AB2) Technical specifications Article number SCALANCE XB008G Attachment to Industrial Ethernet Quantity 8 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GA00-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 78 Operating Instructions, 02/2017, A2B

79 Technical specifications 8.9 SCALANCE XB008G Technical specifications Electrical data Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 650 ma Power loss at 24 VDC Typical 15.6 W Overvoltage category 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 260 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Wall mounting 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q 300 seconds 8192 Blocking Forwarding Yes Operating Instructions, 02/2017, A2B

80 Technical specifications 8.9 SCALANCE XB008G Technical specifications QoS priority queues 4 IEEE 802.1Q tags (VLAN ID, priority) Yes transparent forwarding Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time. Table 8-13 Technical specifications of the SCALANCE XB008G (6GK GA10-1AB2) Technical specifications Article number SCALANCE XB008G Attachment to Industrial Ethernet Quantity 8 Design Properties Transmission rate Permitted cable lengths (Industrial Ethernet) 6GK GA10-1AB2 RJ-45 jacks with MDI-X pinning Half / full duplex 10 / 100 / 1000 Mbps Alternative combinations per length range 0 to 55 m Max. 55 m IE TP Torsion Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 45 m IE TP Torsion Cable 4x2 with IE FC RJ m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 85 m Max. 85 m IE FC TP Marine/Trailing Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 75 m IE FC TP Marine/Trailing Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 0 to 100 m Max. 100 m IE FC TP Standard Cable 4x2 with IE FC RJ45 Plug 180 4x2 Max. 90 m IE FC TP Standard Cable 4x m TP Cord 4x2 via IE FC RJ45 Outlet 80 Operating Instructions, 02/2017, A2B

81 Technical specifications 8.9 SCALANCE XB008G Technical specifications Electrical data Power supply Rated voltage 24 VDC Voltage range Design Current consumption Typical 190 ma Power loss at 24 VDC Typical 4.6 W Overvoltage category 19.2 to 28.8 V DC Safe Extra Low Voltage (SELV) 3-terminal plug-in block CAT II Overvoltage protection at input PTC resettable fuse (1.0 A / 60 V) Permitted ambient conditions Ambient temperature During operation -10 to +60 During storage -40 to +80 During transportation -40 to +80 Relative humidity During operation 95 % no condensation Operating altitude During operation 2,000 m above sea level at max. +60 C ambient temperature Design, dimensions and weight Immunity EN Emission EN Degree of protection MTBF (EN/IEC 61709; 40 C) Housing material Weight Dimensions (W x H x D) IP years Polycarbonate (plastic) 188 g 45 x 100 x 87 mm Installation options Mounting on a DIN rail Switching properties Aging time Max. number of learnable MAC addresses Response to LLDP frames Response to spanning tree BPDU frames CoS acc. to IEEE 802.1Q QoS priority queues 8 IEEE 802.1Q tags (VLAN ID, priority) transparent forwarding Wall mounting 45 seconds Blocking Forwarding Yes Yes 3,000 m above sea level at max. +55 C ambient temperature 4,000 m above sea level at max. +50 C ambient temperature Operating Instructions, 02/2017, A2B

82 Technical specifications 8.10 Mechanical stability (in operation) Note The number of IE switches of the product line connected in a line influences the frame delay. When a frame passes through IE switches of the product line, it is delayed by the store and forward function of the switch with a 64 byte frame length by approx. 10 microseconds (at 100 Mbps) with a 1500 byte frame length by approx. 130 microseconds (at 100 Mbps) This means the more devices of the product line that the frame passes through, the longer the frame propagation time Mechanical stability (in operation) Device DIN EN vibration DIN EN vibration ship building Hz: 7.0 mm PP Hz: 10 m/s 2 1 oct/min, 20 sweeps Hz: 2.0 mm PP Hz: 7 m/s 2 2 min/oct, 1 sweep DIN EN shock 150 m/s 2, 11 ms duration 6 shocks per axis XB004-1 XB004-2 XB004-1LD XB005 XB008 Device DIN EN vibration Hz: 7.0 mm PP Hz: 10 m/s 2 1 oct/min, 20 sweeps DIN EN vibration Hz: 7.0 mm PP Hz: 10 m/s 2 1 oct/min, 20 sweeps DIN EN vibration ship building Hz: 2.0 mm PP Hz: 7 m/s 2 2 min/oct, 1 sweep DIN EN shock 150 m/s 2, 11 ms duration 6 shocks per axis DIN EN permanent shock 250 m/s 2, 6 ms duration 1000 shocks per axis XB004-1G XB004-1LD G XB005G XB008G 82 Operating Instructions, 02/2017, A2B

83 Approvals 9 The SIMATIC NET products described in these Operating Instructions have the approvals listed below. Note Issued approvals on the type plate of the device The specified approvals apply only when the corresponding mark is printed on the product. You can check which of the following approvals have been granted for your product by the markings on the type plate. Current approvals on the Internet You will find the current approvals for the product on the Internet pages of Siemens Industry Online Support ( Notes for the manufacturers of machines The devices are not machines in the sense of the EC Machinery Directive. There is therefore no declaration of conformity relating to the EC Machinery Directive 2006/42/EC for these devices. If the devices are part of the equipment of a machine, they must be included in the declaration of conformity procedure by the manufacturer of the machine. See also SIMATIC NET Industrial Ethernet TP and Fiber Optic Networks ( Installation guidelines The devices meet the requirements if you adhere to the installation and safety instructions contained in this documentation and in the following documentation when installing and operating the devices. "Industrial Ethernet / PROFINET Industrial Ethernet" System Manual "Industrial Ethernet / PROFINET - Passive network components" System Manual You will find information on the system manuals in the section "Auto-Hotspot", in "Further documentation". "EMC Installation Guidelines" configuration manual ( Operating Instructions, 02/2017, A2B

84 Approvals WARNING Personal injury and property damage can occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility. Only use expansions that are approved for the system. Note The test was performed with a device and a connected communications partner that also meets the requirements of the standards listed above. When operating the device with a communications partner that does not comply with these standards, adherence to the corresponding values cannot be guaranteed. EC declaration of conformity The SIMATIC NET products described in these operating instructions meet the requirements and safety objectives of the following EC directives and comply with the harmonized European standards (EN) which are published in the official documentation of the European Union. 2014/34/EU (ATEX explosion protection directive) Directive of the European Parliament and the Council of 26 February 2014 on the approximation of the laws of the member states concerning equipment and protective systems intended for use in potentially explosive atmospheres, official journal of the EU L96, 29/03/2014, pages /30/EU (EMC) EMC directive of the European Parliament and of the Council of February 26, 2014 on the approximation of the laws of the member states relating to electromagnetic compatibility; official journal of the EU L96, 29/03/2014, pages /65/EU (RoHS) Directive of the European Parliament and of the Council of 8 June 2011 on the restriction of the use of certain hazardous substances in electrical and electronic equipment You will find the EC declaration of conformity for these products on the Internet pages of Siemens Industry Online Support ( The EC Declaration of Conformity is available for all responsible authorities at: Siemens Aktiengesellschaft Division Process Industries and Drives Process Automation DE Karlsruhe Germany 84 Operating Instructions, 02/2017, A2B

85 Approvals ATEX (explosion protection directive) WARNING When using SIMATIC NET products in hazardous area zone 2, make absolutely sure that the associated conditions in the following document are adhered to: "SIMATIC NET Product Information Use of subasseblies/modules in a Zone 2 Hazardous Area". You will find this document on the data medium that ships with some devices. on the Internet pages of Siemens Industry Online Support ( Enter the document identification number C234 as the search term. The SIMATIC NET products meet the requirements of the EC directive 94/9/EC "Equipment and Protective Devices for Use in Potentially Explosive Atmospheres. and as of the EC directive 2014/34/EU. ATEX classification: II 3 G Ex na IIC T4 Gc KEMA 07ATEX0145 X The products meet the requirements of the following standards: EN (electrical apparatus for potentially explosive atmospheres; Type of protection "n") EN (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid ATEX certificates. IECEx The SIMATIC NET products meet the requirements of explosion protection according to IECEx. IECEx classification: Ex na IIC T4 Gc DEK X The products meet the requirements of the following standards: IEC (Explosive atmospheres - Part 15: Equipment protection by type of protection "n") IEC (Explosive atmospheres - Part 0: Equipment - General requirements) You will find the current versions of the standards in the currently valid IECEx certificates. Operating Instructions, 02/2017, A2B

86 Approvals EMC directive (electromagnetic compatibility) Until the SIMATIC NET products described in these operating instructions meet the requirements of the EC Directive:2004/108/EC "Electromagnetic Compatibility (EMC directive) and as of the EC directive 2014/30/EU. Field of application Requirements Emission Immunity to interference Industry EN EN You will find the current versions of the standards in the currently valid EC declaration of conformity. RoHS The SIMATIC NET products described in these operating instructions meet the requirements of the EC directive 2011/65/EC for the restriction of the use of certain hazardous substances in electrical and electronic equipment: Applied standard: EN FM The product meets the requirements of the standards: Factory Mutual Approval Standard Class Number 3611 FM Hazardous (Classified) Location Electrical Equipment: Non Incendive / Class I / Division 2 / Groups A,B,C,D / T4 and Non Incendive / Class I / Zone 2 / Group IIC / T4 culus approval for industrial control equipment culus Listed IND. CONT. EQ. Underwriters Laboratories Inc. complying with UL CAN/CSA-IEC Report no. E85972 culus Approval for Information Technology Equipment culus Listed I. T. E. Underwriters Laboratories Inc. complying with UL (Information Technology Equipment) CSA C22.2 No Report no. E Operating Instructions, 02/2017, A2B

87 Approvals culus for Hazardous Locations ANSI/ISA , CSA C22.2 No. 213-M1987 CL. 1, Div. 2 GP. A.B.C.D T.. CL. 1, Zone 2, GP, IIC, T.. (T.. = For detailed information on the temperature class, refer to the type plate) RCM The product meets the requirements of the AS/NZS 2064 standard (Class A). Marking for the customs union EAC (Eurasian Conformity) Customs union of Russia, Belarus and Kazakhstan Declaration of the conformity according to the technical regulations of the customs union (TR CU) MSIP 요구사항 - For Korea only A 급기기 ( 업무용방송통신기자재 ) 이기기는업무용 (A 급 ) 전자파적합기기로서판매자또는사용자는이점을주의하시기바라며, 가정외의지역에서사용하는것을목적으로합니다. Operating Instructions, 02/2017, A2B

88 Approvals FDA and IEC marks The following devices meet the FDA and IEC requirements listed below: Device CLASS 1 LASER Product CLASS 1 LED Product XB XB XB004-1LD - XB XB XB004-1G - XB004-1LDG - XB005G - - XB008G - - CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. 88 Operating Instructions, 02/2017, A2B

SCALANCE XB-000 SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction. Network topologies. Description of the device 3.

SCALANCE XB-000 SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction. Network topologies. Description of the device 3. Introduction 1 Network topologies 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Mounting 4 Connecting up 5 Maintenance and troubleshooting 6 Technical specifications

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction 1. Safety notices 2. Network topologies 3. Description of the device 4

SIMATIC NET. Industrial Ethernet switches SCALANCE XB-000. Introduction 1. Safety notices 2. Network topologies 3. Description of the device 4 Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Network topologies 3 Description of the device 4 Mounting 5 Connecting up 6 Maintenance and troubleshooting

More information

SCALANCE X-100 SIMATIC NET. Industrial Ethernet switches SCALANCE X-100. Introduction 1. Network topologies. Description of the device.

SCALANCE X-100 SIMATIC NET. Industrial Ethernet switches SCALANCE X-100. Introduction 1. Network topologies. Description of the device. Introduction 1 Network topologies 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Assembly 4 Connecting up 5 Maintenance and troubleshooting 6 Technical specifications

More information

SCALANCE XB-200 SIMATIC NET. Industrial Ethernet switches SCALANCE XB-200. Introduction. Safety notices. Description of the device.

SCALANCE XB-200 SIMATIC NET. Industrial Ethernet switches SCALANCE XB-200. Introduction. Safety notices. Description of the device. Introduction Safety notices 1 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 2 Installation 3 Connecting up 4 Upkeep and maintenance 5 Technical specifications

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE X-100. Introduction 1. Network topologies 2. Description of the device 3.

SIMATIC NET. Industrial Ethernet switches SCALANCE X-100. Introduction 1. Network topologies 2. Description of the device 3. Introduction 1 Network topologies 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Assembly 4 Connecting up 5 Maintenance and troubleshooting 6 Technical specifications

More information

SIMATIC NET. S Compact Switch Module CSM Introduction. Network topologies. Product characteristics. Mounting. Approvals and markings

SIMATIC NET. S Compact Switch Module CSM Introduction. Network topologies. Product characteristics. Mounting. Approvals and markings SIMATIC NET S7-1200 Compact Switch Module CSM 1277 Operating Instructions Introduction Network topologies Product characteristics Mounting Approvals and markings References Graphics 1 2 3 4 5 6 7 V. 1.20

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-100. Introduction 1. Safety notices 2. Description of the device 3. Mounting 4.

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-100. Introduction 1. Safety notices 2. Description of the device 3. Mounting 4. Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Mounting 4 Connecting up 5 Maintenance and troubleshooting 6 Technical specifications

More information

SIMATIC NET. Industrial Ethernet SCALANCE X-100 Approvals and markings 5. Introduction. Network topologies. Product properties

SIMATIC NET. Industrial Ethernet SCALANCE X-100 Approvals and markings 5. Introduction. Network topologies. Product properties Introduction Network topologies 1 2 SIMATIC NET Product properties 3 Installation, connecting up, sources of problems 4 Industrial Ethernet Approvals and markings 5 Operating Instructions Technical specifications

More information

SIMATIC NET. SCALANCE Industrial Ethernet SCALANCE X- 100 and SCALANCE X-200 Product Line. Preface. Introduction. Network Topologies

SIMATIC NET. SCALANCE Industrial Ethernet SCALANCE X- 100 and SCALANCE X-200 Product Line. Preface. Introduction. Network Topologies Preface 1 Introduction 2 SIMATIC NET SCALANCE Industrial Ethernet SCALANCE X- 100 and SCALANCE X-200 Product Line Commissioning Manual Network Topologies 3 Product Characteristics 4 Installation and Maintenance

More information

SIMATIC NET. S7-300 Compact Switch Module CSM 377. Introduction. Network topologies 2. Product properties 3. Mounting 4. Approvals and markings 5

SIMATIC NET. S7-300 Compact Switch Module CSM 377. Introduction. Network topologies 2. Product properties 3. Mounting 4. Approvals and markings 5 Introduction 1 Network topologies 2 SIMATIC NET S7-300 Operating Instructions Product properties 3 Mounting 4 Approvals and markings 5 References 6 Graphics 7 Edition 11/07 A2B00073499E Safety Guidelines

More information

SCALANCE X-300 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Introduction 1. Safety instructions. Description. Assembling 4.

SCALANCE X-300 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Introduction 1. Safety instructions. Description. Assembling 4. Introduction 1 Safety instructions 2 SIMATIC NET Industrial Ethernet Switches Compact Operating Instructions Description 3 Assembling 4 Connecting 5 Technical data 6 Dimension drawings 7 Certifications

More information

SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Introduction 1. Safety instructions. Description. Assembling 4.

SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Introduction 1. Safety instructions. Description. Assembling 4. Introduction 1 Safety instructions 2 SIMATIC NET Industrial Ethernet Switches Compact Operating Instructions Description 3 Assembling 4 Connecting 5 Technical data 6 Dimension drawings 7 Certifications

More information

SIMATIC NET. Network components Extender for SCALANCE XM-400. Introduction 1. Safety notices. Description of the device.

SIMATIC NET. Network components Extender for SCALANCE XM-400. Introduction 1. Safety notices. Description of the device. Introduction 1 Safety notices 2 SIMATIC NET Network components Operating Instructions Description of the device 3 Installation 4 Connecting up 5 Technical specifications 6 Dimension drawings 7 A Approvals

More information

SIMATIC SIMIT UNIT V1.3. Introduction 1. Safety instructions 2. Description 3. Installing 4. Wiring 5. Technical specifications 6

SIMATIC SIMIT UNIT V1.3. Introduction 1. Safety instructions 2. Description 3. Installing 4. Wiring 5. Technical specifications 6 Introduction 1 Safety instructions 2 SIMATIC Operating Instructions Description 3 Installing 4 Wiring 5 Technical specifications 6 Dimension drawings 7 Approvals 8 Legal information Warning notice system

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

SCALANCE X-400 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-400. Introduction 1. Safety instructions 2. Description 3.

SCALANCE X-400 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-400. Introduction 1. Safety instructions 2. Description 3. Introduction 1 Safety instructions 2 SIMATIC NET Industrial Ethernet Switches Compact Operating Instructions Description 3 Installation 4 Connecting up 5 Certifications and approvals 6 Technical specifications

More information

SCALANCE X-200 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-200. Preface. Functions. Description of the device.

SCALANCE X-200 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-200. Preface. Functions. Description of the device. Preface Functions 1 SIMATIC NET Industrial Ethernet Switches Operating Instructions Description of the device 2 Safety notices 3 Installation 4 Connecting up 5 Approvals 6 Technical specifications 7 A

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE XR-300M. Introduction 1. Safety notices. Description. Mounting 4.

SIMATIC NET. Industrial Ethernet switches SCALANCE XR-300M. Introduction 1. Safety notices. Description. Mounting 4. Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Compact Operating Instructions Description 3 Mounting 4 Connecting up 5 Technical specifications 6 Dimension drawings 7 Approvals

More information

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation SIMATIC NET PG/PC - Industrial Ethernet Operating Instructions 1 Preface 2 Description of the device 3 Software installation 4 Hardware installation 5 Configuration 6 Technical specifications A Approvals

More information

SCALANCE X-200 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-200. Preface. Functions. Description of the device.

SCALANCE X-200 SIMATIC NET. Industrial Ethernet Switches SCALANCE X-200. Preface. Functions. Description of the device. Preface Functions 1 SIMATIC NET Industrial Ethernet Switches Operating Instructions Description of the device 2 Safety notices 3 Installation 4 Connecting up 5 Approvals 6 Technical specifications 7 A

More information

SIMATIC NET SCALANCE X204RNA SCALANCE X204RNA EEC (PRP) Introduction 1. Safety notes 2. Network topologies and redundancy. Product characteristics 4

SIMATIC NET SCALANCE X204RNA SCALANCE X204RNA EEC (PRP) Introduction 1. Safety notes 2. Network topologies and redundancy. Product characteristics 4 Introduction 1 Safety notes 2 SIMATIC NET SCALANCE X204RNA SCALANCE X204RNA EEC (PRP) Operating Instructions Network topologies and redundancy 3 Product characteristics 4 Installation 5 Connection 6 Functional

More information

SIMATIC NET. Network components SCALANCE TAP. Introduction 1. Safety notices. Description of the device. Mounting 4.

SIMATIC NET. Network components SCALANCE TAP. Introduction 1. Safety notices. Description of the device. Mounting 4. Introduction 1 Safety notices 2 SIMATIC NET Network components Operating Instructions Description of the device 3 Mounting 4 Connecting up 5 Technical specifications 6 Dimension drawings 7 Certifications

More information

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1

SIMATIC NET. Industrial Ethernet Security SCALANCE S615 Getting Started. Preface. Connecting SCALANCE S615 to the WAN 1 Preface Connecting SCALANCE S615 to the WAN 1 SIMATIC NET VPN tunnel between SCALANCE S615 and 2 SINEMA RC Server Industrial Ethernet Security Getting Started 07/2017 C79000-G8976-C390-02 Legal information

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE X-000. Introduction 1. Safety notices 2. Network topologies 3. Description of the device 4

SIMATIC NET. Industrial Ethernet switches SCALANCE X-000. Introduction 1. Safety notices 2. Network topologies 3. Description of the device 4 Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Network topologies 3 Description of the device 4 Mounting 5 Connecting up 6 Maintenance and troubleshooting

More information

SIMATIC NET SCALANCE X204RNA SCALANCE X204RNA EEC (HSR) Introduction. Safety notes. Network topologies and redundancy. Product characteristics

SIMATIC NET SCALANCE X204RNA SCALANCE X204RNA EEC (HSR) Introduction. Safety notes. Network topologies and redundancy. Product characteristics Introduction Safety notes 1 2 SIMATIC NET Network topologies and redundancy 3 Product characteristics 4 SCALANCE X204RNA SCALANCE X204RNA EEC (HSR) Operating Instructions Installation Connection Functional

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface 1 Description of the device 2 SIMATIC NET PG/PC - Industrial Ethernet Operating Instructions Software installation 3 Hardware installation 4 Configuration 5 Technical specifications 6 A Approvals

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

SIMATIC NET. SCALANCE S and SOFTNET Security Client A B C D E. Preface, Contents

SIMATIC NET. SCALANCE S and SOFTNET Security Client A B C D E. Preface, Contents Preface, Contents SIMATIC NET SCALANCE S and SOFTNET Security Client Operating Instructions Introduction and basics 1 Product properties and commissioning 2 GETTING STARTED 3 Configuring with the Security

More information

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL. Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE XB-200. Introduction 1. Safety notices. Description of the device. Installation 4.

SIMATIC NET. Industrial Ethernet switches SCALANCE XB-200. Introduction 1. Safety notices. Description of the device. Installation 4. Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Installation 4 Connecting up 5 Upkeep and maintenance 6 Technical specifications

More information

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2 Use with 0 to 70 C ambient temperature SIMATIC Preface 1 Product combination 2 Product family 3 Process Control System PCS 7 Use with 0 to 70 C ambient temperature System Manual 02/2015 A5E35458345-AA

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

SCALANCE X- SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Preface. Safety instructions. Introduction 2. Network topologies 3

SCALANCE X- SIMATIC NET. Industrial Ethernet Switches SCALANCE X-300. Preface. Safety instructions. Introduction 2. Network topologies 3 SCALANCE X- 300 Preface Safety instructions 1 SIMATIC NET Industrial Ethernet Switches Operating Instructions Introduction 2 Network topologies 3 Description of the device 4 Installation 5 Connecting 6

More information

SIMATIC NET. SIMATIC NET Industrial Ethernet SCALANCE X101-1AUI. Introduction. Network Topologies. Product Characteristics 3

SIMATIC NET. SIMATIC NET Industrial Ethernet SCALANCE X101-1AUI. Introduction. Network Topologies. Product Characteristics 3 Introduction 1 Network Topologies 2 SIMATIC NET SIMATIC NET Industrial Ethernet SCALANCE X101-1AUI Commissioning Manual Product Characteristics 3 Installation and Maintenance 4 Notes on the CE Mark 5 References

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-200. Introduction 1. Safety notices. Description of the device. Mounting 4.

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-200. Introduction 1. Safety notices. Description of the device. Mounting 4. Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Mounting 4 Connecting up 5 Maintenance and troubleshooting 6 Technical specifications

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview. IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address space 4 Diagnostics alarms

More information

SIMATIC NET. Industrial Ethernet / PROFIBUS IE/PB LINK PN IO. Preface. Application and properties. LEDs, connectors, buttons 2

SIMATIC NET. Industrial Ethernet / PROFIBUS IE/PB LINK PN IO. Preface. Application and properties. LEDs, connectors, buttons 2 Preface Application and properties 1 SIMATIC NET Industrial Ethernet / PROFIBUS Operating Instructions LEDs, connectors, buttons 2 Installation, connecting up, commissioning 3 Configuration and operation

More information

SCALANCE M812, M816 SIMATIC NET. Industrial Remote Communication Remote Networks SCALANCE M812, M816. Preface. Description of the device

SCALANCE M812, M816 SIMATIC NET. Industrial Remote Communication Remote Networks SCALANCE M812, M816. Preface. Description of the device Preface Description of the device 1 SIMATIC NET Industrial Remote Communication Remote Networks Operating Instructions Installation 2 Connecting up 3 Dimension drawing 4 Technical specifications 5 A Approvals

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters

More information

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional Setting up security in STEP 7 Professional SIMATIC NET Industrial Ethernet Security Setting up security in STEP 7 Professional Preface 1 User interface and menu commands 2 Basic configuration 3 Firewall

More information

SCALANCE XR-500 SIMATIC NET. Industrial Ethernet switches SCALANCE XR-500. Introduction 1. Safety notes. Description of the device.

SCALANCE XR-500 SIMATIC NET. Industrial Ethernet switches SCALANCE XR-500. Introduction 1. Safety notes. Description of the device. Introduction 1 Safety notes 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Assembling 4 Connecting 5 Uninstalling 6 Upkeep and maintenance 7 Technical data

More information

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode Global FW Rulesets SIMATIC NET Industrial Ethernet Security Preface 1 Firewall in standard mode 2 Firewall in advanced mode 3 Configuring a VPN tunnel 4 Configuring remote access via a VPN tunnel 5 Getting

More information

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2 BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Manual Preface Guide to the documentation 1 Product overview 2 BaseUnits for I/O modules 3 BaseUnits

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0) 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- SIMATIC Preface 1 Properties 2 Diagnostics 3 ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- Manual 10/2015

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A AC24..230V/5A (6ES7132-4HB50-0AB0) SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A

More information

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618 1 SIMATIC Sensors RF systems Wide-range power supply unit for SIMATIC RF systems Operating Instructions 11/2007 J31069-D0169-U001-A4-7618 Safety Guidelines This manual contains notices you have to observe

More information

ST (6ES7132-6FD00-0BB1)

ST (6ES7132-6FD00-0BB1) SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ

More information

CP 5711 SIMATIC NET PG/PC - PROFIBUS CP Preface. Description of the device. Software installation. Hardware installation.

CP 5711 SIMATIC NET PG/PC - PROFIBUS CP Preface. Description of the device. Software installation. Hardware installation. SIMATIC NET PG/PC - PROFIBUS Operating Instructions Preface 1 Description of the device 2 Software installation 3 Hardware installation 4 Configuration 5 Technical specifications A Approvals B Dimension

More information

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-200. Introduction 1. Safety notices 2. Description of the device 3. Mounting 4.

SIMATIC NET. Industrial Ethernet switches SCALANCE XC-200. Introduction 1. Safety notices 2. Description of the device 3. Mounting 4. Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet switches Operating Instructions Description of the device 3 Mounting 4 Connecting up 5 Maintenance and troubleshooting 6 Technical specifications

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties. Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 06/2010

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

SIMATIC NET. Industrial Ethernet security SCALANCE SC-600. Introduction 1. Safety notices 2. Security recommendations 3. Description of the device 4

SIMATIC NET. Industrial Ethernet security SCALANCE SC-600. Introduction 1. Safety notices 2. Security recommendations 3. Description of the device 4 Introduction 1 Safety notices 2 SIMATIC NET Industrial Ethernet security Operating Instructions Security recommendations 3 Description of the device 4 Mounting 5 Connection 6 Service and maintenance 7

More information

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties. Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3. Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01 Safety Guidelines This manual contains notices

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01- SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A

More information

SIMATIC NET. S TeleControl CP Preface. Application and properties 1. LEDs and connectors 2. Installation, connecting up, commissioning

SIMATIC NET. S TeleControl CP Preface. Application and properties 1. LEDs and connectors 2. Installation, connecting up, commissioning Preface Application and properties 1 SIMATIC NET S7-1200 - TeleControl Operating Instructions LEDs and connectors 2 Installation, connecting up, commissioning 3 Configuration 4 Program blocks 5 Diagnostics

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2.

SIMATIC. Process Control System PCS 7 Configuration McAfee Endpoint Security Security information 1. Preface 2. Security information 1 Preface 2 SIMATIC Configuration 3 Process Control System PCS 7 Configuration McAfee Endpoint Security 10.5 Installation Manual 03/2018 A5E44395618-AA Legal information Warning notice

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Automation System S7-300: Getting Started CPU 31xC: Commissioning Introduction 1 Preparation 2 SIMATIC S7-300 Automation System S7-300: Getting Started CPU 31xC: Commissioning Learning units 3 Further

More information

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No SIMADYN D Digital Control System User Manual Fiber-Optic Rack Coupling CS12 Edition 05.95 DK No. 237741 User Manual, Fiber-Optic Rack Coupling CS12 Edition Status 1 Fiber-Optic Rack Coupling CS12 05.95

More information

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC S7-1500/ET 200MP Digital output module DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) Manual Preface Documentation guide 1 Product overview

More information

SIMATIC. ET 200SP BusAdapter. Preface 1. Guide. Product overview. BusAdapter BA 2xRJ45 4. BusAdapter BA 2xFC 5. BusAdapter BA 2xSCRJ 6.

SIMATIC. ET 200SP BusAdapter. Preface 1. Guide. Product overview. BusAdapter BA 2xRJ45 4. BusAdapter BA 2xFC 5. BusAdapter BA 2xSCRJ 6. Siemens Controls Preface 1 Guide 2 SIMATIC ET 200SP BusAdapter Manual Product overview 3 BusAdapter BA 2xRJ45 4 BusAdapter BA 2xFC 5 BusAdapter BA 2xSCRJ 6 BusAdapter BA SCRJ/RJ45 7 BusAdapter BA SCRJ/FC

More information

SIEMENS. BANY Agent. Compact Operating Instructions. BANY Agent 1 Compact Operating Instruction

SIEMENS. BANY Agent. Compact Operating Instructions. BANY Agent 1 Compact Operating Instruction SIEMENS BANY Agent s BANY Agent 1 Legal Information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property.

More information

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0) SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01

More information

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3 1BProduct information on CPU 1515SP PC Preface Product Information 1 SIMATIC ET 200SP Open Controller Technical update 2 Technical specifications 3 Product Information 09/2015 A5E35456639-AC 3BLegal information

More information

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v IES-0920 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail User Manual v1.00-1206 Preface This manual describes how to install and use the Industrial Ethernet Switch. This switch integrates full wire

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual

CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 RS232 to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.1.S - 0 CMU 100 / 7.1.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.1.S - 0 User manual CMUMU11S

More information

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system

SIMATIC. Industrial PC Microsoft Windows 7 (USB stick) Safety instructions 1. Initial startup: Commissioning the operating system Safety instructions 1 Initial startup: Commissioning the operating system 2 SIMATIC Industrial PC Operating Instructions Restoring the factory settings of the operating system and partitions(restore) 3

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.8 07/2016 A5E00331460A Legal

More information

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual

CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 Multimode Fiber Optic to Singlemode Fiber Optic Converter User Manual CMU 100 / 1.6.S - 0 CMU 100 / 7.6.S - 0 Company: Device: Document: Code: Version: Date: Ediseja 21 CMU 100 / 1.6.S - 0 User

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Unmanaged Industrial Ethernet Switches

Unmanaged Industrial Ethernet Switches Siemens AG 2017 Brochure Edition 11/2016 Un Industrial Ethernet Switches Cost-effective setup of small networks As active network components, Ethernet switches permit the structuring of an industrial communication

More information

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G) Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches Installation Guide P/N 5500339-10 (Rev G) Overview This document contains instructions necessary for the installation and operation of the Perle IDS-108F

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET. PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Introduction 1. Components of the product

PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET. PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Introduction 1. Components of the product PROFIBUS Optical Bus Terminal (OBT) SIMATIC NET PG/PC - PROFIBUS PROFIBUS Optical Bus Terminal (OBT) Operating Instructions Introduction 1 Components of the product 2 Functional description 3 Network topology

More information

Quick Start Guide. Physical Description. The Port Status LEDs

Quick Start Guide. Physical Description. The Port Status LEDs Quick Start Guide This quick start guide describes how to install and use the Hardened PoE Ethernet Switch. Capable of operating at temperature extremes of -40 C to +75 C, this is the switch of choice

More information

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface Safety instructions 1 SIMATIC NET Industrial Ethernet Switches Operating Instructions Introduction 2 Network topologies 3 Description of the device 4 Installation 5 Connecting 6 Configuration,

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) SIMATIC ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Connecting 3 Parameter

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

SIMATIC NET. Industrial Remote Communication Remote Networks SCALANCE M826. Preface. Security recommendations. Description of the device

SIMATIC NET. Industrial Remote Communication Remote Networks SCALANCE M826. Preface. Security recommendations. Description of the device Preface Security recommendations 1 SIMATIC NET Industrial Remote Communication Remote Networks Operating Instructions Description of the device 2 Installation 3 Connecting up 4 Dimension drawings 5 Technical

More information

Operating Instructions SIMATIC. Network transitions. PN/M-Bus LINK. siemens.com

Operating Instructions SIMATIC. Network transitions. PN/M-Bus LINK. siemens.com Operating Instructions SIMATIC Network transitions Edition 03/2018 siemens.com Introduction 1 Safety information 2 SIMATIC Network transitions Operating Instructions System overview 3 Functions 4 Application

More information

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v

IES User Manual. 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail. v IES-0823 6 GE + 2 SFP Unmanaged Switch -20 to 60C, DIN-rail User Manual v1.00-1206 Preface A member of the growing family of rugged switches, this switch addresses a need for a smaller switch. This switch

More information

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting. Device manual SINAMICS SINAMICS G120 Control cabinet for wall or floor mounting Edition 06/2018 www.siemens.com/drives Safety note 1 Description 2 SINAMICS SINAMICS G120 Manual Mounting 3 Connection 4

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V/AC24..230V (6ES7138-4CB11-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 04/2007

More information

SIMATIC NET PG/PC - PROFIBUS CP Preface. Description of the device 1. Software installation 2. Hardware installation 3.

SIMATIC NET PG/PC - PROFIBUS CP Preface. Description of the device 1. Software installation 2. Hardware installation 3. Preface Description of the device 1 SIMATIC NET PG/PC - PROFIBUS Operating Instructions Software installation 2 Hardware installation 3 Configuration 4 Technical specifications 5 A Approvals 08/2016 C79000-G8976-C278-03

More information