1 Bi-power Relays LY E Power-switching Compact General-purpose Relays The standard models include models that are compliant with the UL, CSA, and SEV safety standards and with the Electrical Appliances and Material Safety Act. Equipped with an arc barrier for arc interruption. Withstand voltages up to, V. New built-in diode and built-in CR circuit models have joined the series. The lineup also includes models that are compliant with the LR and VDE safety standards. Single-pole and double-pole models have AC4 ratings and DC ratings (operating coil ratings: / VAC, / VAC, / VAC, /4 VAC, and / VDC). Three-pole and four-pole models have AC4 ratings and DC ratings (operating coil ratings: / VAC, / VAC and / VDC). Refer to the standards certifications and compliance section of your OMRON website for the latest information on certified models. Refer to the Common Relay Precautions. Number Structure Structure Relays with Plug-in Terminals Relays with PCB Terminals Case-surface mounting Classification Standard models Compliance with Electrical Appliances and Material Safety Act s with diode for coil surge absorption (DC coil specification only) s with CR circuits for coil surge absorption (AC coil specification only) Number of poles With operation indicators **LY-D **LYN-D **LY4-D **LY4N-D **LY-CR **LYN-CR *LY **LYN *LY- *LYF *LY **LYN *LY- *LYF Bifurcated **LYZ **LYZN **LYZ- **LYZF *LY **LYN *LY- *LYF 4 *LY4 **LY4N *LY4- *LY4F **LY-D **LYN-D **LY-D **LYN-D Bifurcated **LYZ-D **LYZN-D Bifurcated **LYZ-CR **LYZN-CR Note:. Cells with a diagonal line cannot be manufactured. Ask your OMRON representative for details on manufacturing products for cells containing --- in the above table.. If #7 tab terminals are required, use the LYF-T or LYF-T (single-pole or double-pole models only).. Refer to page 6 for information on plug-in terminal and socket combinations. 4. Items with an asterisk (*) in the table are certified for UL, CSA, and SEV. This is indicated with a certification mark on the products.. Items with two asterisks (**) in the table are certified for UL and CSA. This is indicated with a certification mark on the products. 6. All models in the table are certified for IEC (TÜV). 7. The models with plug-in terminals (single-pole, double-pole, and 4-pole) were combined with the PTF-E for the EC Declaration of Conformity. These products display the CE Marking.

2 Ordering Information Relays s with Plug-in Terminals Number of poles pole poles poles 4 poles Classification Rated Rated Rated Rated, 4, /,, 4, /,/, 4, /, or, 4, /, or /,, /, / VAC / VAC Standard models LY or / VAC LY or/4 VAC LY LY4 s with single contacts Bifurcated contacts operation indicators diodes diodes and operation indicators CR circuits CR circuits and operation indicators Standard models operation indicators diodes diodes and operation indicators CR circuits CR circuits and operation indicators Relays with PCB Terminals Case-surface Mounting, 4, 4, or / VDC, 4, /, /, LYN or / VAC, 4, or / VDC, 4, 4, LY-D or / VDC LYN- D LYN LY-D, 4, or 4 VDC LYN-D, 4, 4, or / VDC, 4, /,/, /, or /4 VAC, 4, 4, or / VDC, 4, 4, or / VDC, 4, 4, or / VDC LYN LY-D LYN- D, 4, 4, or / VDC, 4, /, or / VAC, 4, 4, or / VDC, 4, 4, or / VDC, 4, or / VDC, 4, 4, or / VDC LY, 4, /, or / VAC LY4N, 4, 4, or / VDC, 4, 4, LY4-D or / VDC LY4N- D, 4, 4, or / VDC LY-CR /, /, /, or /4 VAC /, /, LYN-CR /, or / VAC / or/ VAC LYZ, 4, 4, or / VDC /, /, /, LYZN or /4 VAC or 4 VDC LYZ-D, 4, or 4 VDC LYZN- D, 4, or / VDC LYZ-CR / VAC LYZN- CR,, /, or / VAC Number of poles pole poles poles 4 poles Classification Rated Rated Rated Rated 4,/,, 4, 4, /, 4, /, or / /, or / /, /, / s with single or / VAC VAC LY- VAC LY-, or /4 VAC LY- LY4- contacts, 4, 4, 4, 4, or, 4, 4, or or 4 VDC or / VDC / VDC / VDC / VAC --- Bifurcated contacts LYZ- 4, 4, or / VDC --- Number of poles pole poles poles 4 poles Classification Rated Rated Rated Rated 4, /,, 4, /, /, 4, /,, 4, /, /, /,, /, or / VAC or / VAC LYF or /4 VAC LYF or /4 VAC LYF LY4F s with single contacts 6,, 4, or / VDC Bifurcated contacts LYZF, 4, 4, or / VDC 4, /, or / VAC or 4 VDC, 4, or / VDC, 4, or / VDC

3 Accessories (Order Separately) Connection Sockets Connecting method Mounting method Number of poles PTFA or PTFA-E * Front-mounting Sockets (PTA@) Track or screw mounting PTFA 4 PTF4A PTF4A-E * Back-mounting Sockets (PT@) *. The PTF@A-E Relays have finger protection. Round terminals cannot be used. Use forked terminals. *. When ordering PT, PT, or PT4 sockets, please note that the minimum order quantity is and orders are accepted in multiples of the minimum order. Relay Hold-down Clips Solder terminals Wrapping terminals Relays with PCB Terminals or PT * PT * 4 PT4 * or PTQN PTQN 4 PT4QN or PT- PT- 4 PT4- Application Item Used with Socket Used with Socket mounting plate For models with built-in CR circuits Approx. Approx.. Appearance PYC-A PYC-P PYC-S Y9H- PYC- Minimum order (quantity) * * Orders are accepted in multiples of the minimum order. Socket Mounting Plates Applicable sockets Number of sockets PYP- * PT PTQN PYP- * 6 PYP-6 * PT PTQN PT4 PT4QN PTP-- PTP- PTP- PTP- *. When ordering PYP-, please note that the minimum order quantity is and orders are accepted in multiples of the minimum order. *. PYP- and PYP-6 can be cut to any required length.

4 Ratings and Specifications Ratings Standard s with Built-in Operation Indicators Operating Coil, Single-pole and Double-pole s Item Rated current (ma) Coil Coil inductance (H) Rated voltage resistance Armature Hz 6Hz (V) (Ω) OFF Armature ON AC /.7/.9 /, / 9.9/..4/9. 4,4 9.. / 6./6../., /4 4./. 4./4.6, DC ,6.6. / 9./, poles Rated voltage (V) AC DC Item Rated current (ma) Coil Hz 6Hz resistance (Ω) Coil inductance (H) Armature OFF Armature ON / 4./6.4/.7,.. / 9./. 7.7/., ,7..9 /.7/, Must-operate % max. * Must-operate % max. * Must-release % min. * Maximum % of rated voltage LY Power consumption (VA, W) Approx.. to. (at 6 Hz) Approx..9 to. (at 6 Hz) % min. * Approx..9 Must-release % min. * Maximum % of rated voltage Power consumption (VA, W) Approx..6 to. (at 6 Hz) % min. * Approx..4 4 poles Item Rated current (ma) Coil Coil inductance (H) Rated voltage resistance Armature Hz 6Hz (V) (Ω) OFF Armature ON AC /./. 9/.,. 7. /./. 9./. 6, DC 4, / /.9 6, Must-operate % max. * Must-release % min. * Maximum % of rated voltage Power consumption (VA, W) Approx..9 to. (at 6 Hz) % min. * Approx.. Note:. The rated current and coil resistance are measured at a coil temperature of C with tolerances of +%/ % for the AC rated current and ±% for the DC coil resistance.. The AC coil resistance and inductance values are reference values only. (at 6 Hz).. Operating characteristics were measured at a coil temperature of C. 4. The maximum voltage capacity was measured at an ambient temperature of C. *. There is variation between products, but actual values are % max. To ensure operation, apply at least % of the rated value (at a coil temperature of + C). *. The actual values are % min. for AC and % min. for DC. To ensure release, use a value that is lower than the specified value. 4

5 Refer to List of Certified s for a list of models that are certified for safety standards and the Electrical Appliances and Material Safety Act. Classification pole Double-, -, and 4-pole models Bifurcated contacts Item Load Resistive load Characteristics Inductive load (cos φ =.4, L/R = 7 ms) Resistive load Inductive load (cos φ =.4, L/R = 7 ms) Resistive load Contact type Single Bifurcated Contact materials Ag alloy Ag Rated load A at VAC A at 4 VDC A at VAC 7 A at 4 VDC A at VAC A at 4 VDC 7. A at VAC A at 4 VDC A at VAC A at 4 VDC Rated carry current A A 7 A Maximum contact voltage VAC VDC VAC VDC Inductive load (cos φ =.4, L/R = 7 ms) VAC VDC 4 A at VAC 4 A at 4 VDC Maximum contact current A A A A 7 A 7 A Item Ambient operating temperature Ambient operating humidity Item Type Single-pole and double-pole models (standard models and bifurcated contact models) to C (with no icing or condensation) * Type Single-pole, double-pole models (models with built-in operation indicators, models with built-in diodes, and models with built-in CR circuits), -pole and 4-pole models to +4 C (with no icing or condensation) * % to % Standard models, models with built-in operation indicators, models with built-in CR circuits, and models with built-in diodes Bifurcated contacts Note:. Some models in the LY and LY Series have an upper temperature limit of +4 C. This limitation is due to the diode junction temperature and the elements used.. Refer to Ambient Temperature vs. Coil Temperature Rise in Engineering Data on page to 9 for information on operation in temperature conditions that are not described here.. When you apply a minimum of A of current to an LY when it is used in combination with a PTFA, PTFA- E, or PT, connect each of the following terminal pairs: () to (), () to (4), and () to (6). *. If the carry current is 4 A or less, the usable ambient temperature range is to 7 C. *. If the flowing current is 4 A or less, the usable ambient temperature range is - to C. Contact resistance * mω max. Note: The values at the left are initial values. Operating time * ms max. Release time * ms max. Maximum Mechanical, operations/h operating frequency Rated load, operations/h Insulation resistance * Between coil and contacts Dielectric strength Vibration resistance Shock resistance Endurance MΩ min. Between contacts of, VAC at /6 Hz for min. different polarity Between contacts of the same polarity, VAC at /6 Hz for min. Destruction to to Hz,.-mm single amplitude (.-mm double amplitude) Malfunction to to Hz,.-mm single amplitude (.-mm double amplitude) Destruction, m/s Malfunction m/s Mechanical Electrical *4 AC:,, operations min. DC:,, operations min. -, -, 4-pole:, operations min. -pole:, operations min. (rated load, operating frequency:, operations/h) (switching frequency:, operations/h) -pole:, operations min. (rated load, operating frequency:, operations/h) Failure rate P value (reference value) * ma at VDC ma at VDC Weight -pole and -pole: 4 g, -pole: Approx. g, 4-pole: Approx. 7 g *. Measurement conditions: A at VDC using the voltage drop method *. Measurement conditions: With rated operating power applied, not including contact bounce. Ambient temperature condition: C *. Measurement conditions: For VDC applied to the same location as for dielectric strength measurement. *4. Ambient temperature condition: C *. This value was measured at a switching frequency of operations per minute. Endurance Under Real Loads (Reference Only) Load type AC motor AC lamp Capacitor (, µf) AC solenoid Item LY, VAC LY, VAC LY4, VAC Conditions 4 W, VAC singlephase with -A inrush current, 7-A current flow Operating frequency ON for s, OFF for s W, VAC with -A inrush current, - A current flow ON for s, W, VAC with OFF for s 7-A inrush current, - A current flow 4 VDC with -A inrush current, -A current flow ON for s, OFF for 6 s VA with.-a inrush current,.-a current flow ON for s, VA with -A inrush OFF for s current,.-a current flow Electrical life (, operations min.). Conditions W, VAC singlephase with -A inrush current, -A current flow W, VAC with -A inrush current, - A current flow Operating frequency ON for s, OFF for s ON for s, OFF for s 4 VDC with -A inrush current, -A current flow ON for s, 4 VDC with -A OFF for s inrush current, -A current flow VA with.-a inrush current,.-a current flow ON for s, VA with -A inrush OFF for s current,.-a current flow Electrical life (, operations min.) Conditions Operating frequency W, VAC threephase with -A inrush current, -A current flow ON for s, 7 W, VAC threephase with -A inrush OFF for s current,.-a current flow W, VAC with -A inrush current, - A current flow 4 VDC with -A inrush current, -A current flow 4 VDC with -A inrush current, -A current flow VA with.-a inrush current,.-a current flow VA with -A inrush current,.-a current flow ON for s, OFF for s ON for s, OFF for s ON for s, OFF for s ON for s, OFF for s Electrical life (, operations min.) 7.

6 Details on Safety-standard-certified s, Standard models are certified for the UL, CSA, and SEV safety standards. Refer to Number Structure on page for a list of applicable models. The rated values for safety standard certification are not the same as individually defined performance values. Always check the specifications before use. UL-certified s (File No. E464) LY Coil ratings 6 to 4VAC 6 to VDC 6 to 4VAC 6 to VDC 6 to 4VAC 6 to VDC Number of poles 4 Contact ratings Certified number of operations A, VAC (General use), operations A, 4VAC (General use) A, VDC (Resistive) /HP, VAC.FLA, LRA, VAC TV-, VAC 47VA, Pilot duty, VAC, operations, operations A, VAC (General use), operations A, 4VAC (General use) 7A, VAC (General use) A, VDC (Resistive) A, VDC (Resistive) /HP, VAC /HP, 4VAC.FLA, LRA, VAC FLA, LRA, VDC TV-, VAC 4VA, Pilot duty, -4VAC B/R A, 4VAC (General use) (Same polarity) A, VDC (General use) (Same polarity) A, 4VDC (Resistive) (Same polarity) /HP, 4VAC.6A, VDC (Resistive) (Same polarity), operations, operations, operations, operations, operations CSA-certified s (File No. LR9) LY Coil ratings 6 to 4VAC 6 to VDC 6 to 4VAC 6 to VDC 6 to 4VAC 6 to VDC Number of poles 4 Contact ratings Certified number of operations A, VAC (General use), operations A, 4VAC (General use) A, VDC (Resistive) /HP, VAC.FLA, LRA, VAC TV-, VAC 47VA, Pilot duty, VAC A, VAC (General use) A, 4VAC (General use) 7A, VAC (General use) A, VDC (Resistive) A, VDC (Resistive) /HP, VAC /HP, 4VAC.FLA, LRA, VAC FLA, LRA, VDC TV-, VAC 4VA, Pilot duty, -4VAC B/R Pilot duty A, 4VAC (General use) (Same polarity) A, VDC (Resistive) (Same polarity) /HP, 4VAC (Same polarity) /HP, 4VAC (Same polarity) /HP, 4VAC (Same polarity) A, 4VDC (Resistive).6A, VDC (Resistive), operations, operations, operations, operations, operations, operations, operations TÜV-certified s (File No. R64, EN 6-) LY@ Coil ratings 6 to 4 VAC 6 to VDC Number of poles Contact ratings A, VDC A, VAC inductive load A, VAC 7A, VAC inductive load A, VDC 7 A, VDC inductive load A, VAC 7.A, VAC inductive load 7A, VAC 4 A, VAC inductive load 7 A, VDC 4 A, VDC inductive load Certified number of operations, operations SEV-certified s (File No., 7) LY@ Coil ratings 6 to VDC to 4 VAC 6 to VDC to 4 VAC Number of poles to 4 A at 4 VDC A at VAC Contact ratings A at 4 VDC A at VAC Certified number of operations 4 A, VAC, 7.A, VAC inductive load operations 6

7 When ordering a model that is certified for VDE or Lloyd s Register (LR) standards, always specify VDE-certified or LR Standard-certified with your order. VDE Certification (Certificate No. 69, EN 6-) Coil ratings Number of poles Contact ratings Certified number of operations A, VAC LY@-VD 6,, 4,,, or VAC 6,, 4, 4, or VDC 7 A, VAC inductive load A, VDC 7 A, VDC inductive load 7 A, VAC 4 A, VAC inductive load 7 A, VDC, operations 4 A, VDC inductive load LR-certified s (File No. /47) LY@ 6 to 4 VAC 6 to VDC Coil ratings Number of poles Contact ratings 7. A, VAC inductive load 4 A, 4 VDC inductive load Details on Safety-standard-certified s, Sockets UL-certified s (File No. E799) PTFA(-E) PT PTF4A(-E) PT PT4 PTFA Ratings A V A V Standard number Category UL SWIV Recognized Listed/Recognized CSA-certified s (File No. LR9) Ratings Standard number Class number PTFA(-E) PTFA PTF4A(-E) A 4V AC A 4V AC CSA C. (No.4) 7 CE Marking Compliance PTFA(-E) PTF4A(-E) EMC Directive Low Voltage Directive Machinery Directive Not applicable Not applicable Safety Category Note:. CE compliance is achieved when used with a relay (LY).. The Safety Category refers to the maximum applicable category selected when constructing control system safety components. The category does not apply to individual components. Compliance with Electrical Appliances and Material Safety Act, LY@ All standard models comply with the Electrical Appliances and Material Safety Act. LY@ 6 to 4 VAC 6 to VDC Coil ratings Number of poles A at VAC A at VAC 4 Contact ratings 7

8 Engineering Data Engineering Data Maximum Switching Capacity LY LY LY and LY4 LY Contact current (A) AC inductive load (cos φ =.4) AC Life:, operations Contact current (A) AC inductive load (cos φ =.4) AC Life:, operations Contact current (A) AC inductive load (cos φ =.4) AC Life:, operations. DC inductive load (L/R = 7 ms). DC inductive load (L/R = 7 ms). DC inductive load (L/R = 7 ms) DC DC DC..., Contact, Contact Endurance Curve LYZ LY LY, Contact Contact current (A).. DC inductive load (L/R = 7 ms) Life:, operations DC AC AC inductive load (cos φ =.4), Contact Number of operations ( 4 operations), VAC 4 VDC 4 VDC VAC inductive load inductive load (cos φ =.4) (L/R = 7 ms) Switching current (A) 4 VDC VAC VAC inductive load (cos φ =.4) 4 VDC inductive load (L/R = 7 ms) Ambient Temperature vs. Mustoperate and Must-release Voltage LY and LY4 LYZ LY / VAC at Hz Number of operations ( 4 operations), 4 VDC 4 VDC inductive load (L/R = 7 ms) VAC VAC inductive load (cos φ =.4) Switching current (A) Number of operations ( 4 operations), 4 VDC VAC VAC inductive load (cos φ =.4) 4 VDC inductive load (L/R = 7 ms) 4 6 Switching current (A) Ambient Temperature vs. Coil Temperature Rise LY 4 VDC LY 4 VDC LY / VAC at Hz Number of operations ( 4 operations) Must-operate/must-release voltage (%), Switching current (A) Number of Relays: (average value) Must-operate voltage Must-release voltage Must-operate/must-release voltage (%) 6 4 Number of Relays: (average value) Must-operate voltage Must-release voltage Coil temperature rise ( C) 9 A 7 A 6 7 A A A 4 No contact current Rating: % applied Rated power consumption: W Maximum operating temperature ( C) Coil temperature rise ( C) A A 7 A A A No contact current Rating: % applied Rated power consumption: VA Maximum operating temperature ( C)

9 LY 4 VDC LY / VAC at Hz LY 4 VDC Coil temperature rise ( C) A 7 A A A No contact current Rating: % applied Rated power consumption: W Maximum operating temperature ( C) Coil temperature rise ( C) A 7 A A A No contact current Rating: % applied Rated power consumption:. VA Maximum operating temperature ( C) Coil temperature rise ( C) A 7 A A A No contact current Rating: % applied Rated power consumption:.4 VA Maximum operating temperature ( C) LY / VAC at Hz LY4 4 VDC LY4 / VAC at Hz Coil temperature rise ( C) A 7 A A A No contact current Rating: % applied Rated power consumption:.6 VA Maximum operating temperature ( C) Coil temperature rise ( C) A 7 A A A No contact current Rating: % applied Rated power consumption:. W Maximum operating temperature ( C) Coil temperature rise ( C) A 7 A A A No contact current Rating: % applied Rated power consumption:.9 VA Maximum operating temperature ( C) diodes The diode absorbs surge from the coil. With Diode Without Diode ON OFF ON OFF 4 V A 4 VDC To digital Di memory 4 VDC A To digital memory A A Note:. Make sure that the polarity is correct.. The release time will increase, but the -ms specification for standard models is satisfied.. Diode characteristics: Reversed dielectric strength:, V Forward current: A s with Built-in CR Circuits With CR Without CR V V. msec V AC 9.4 ms A C =. μf R = Ω A 4. ms AC A To digital memory scope A 6 V 9

10 Malfunctioning Shock LY / VAC X 7 Y 6 44 Energized Not energized 7 Z N = Measurement: Shock was applied times each in 6 directions along axes with the Relay energized and not energized to check the shock values that cause the Relay to malfunction. Criteria: Non-energized: m/s, Energized: m/s 7 Z' 6 Unit: m/s 4 X' Shock direction X X' Y Z Z' Y' Dimensions Relays Solder terminals LY LYN LY-D LYN-D Y' (Unit: mm) Terminal Arrangement/Internal Connections (Bottom View) LY LYN-D. 6 max. Eight, -dia. holes 6.4. max. max. LYN (Check the coil polarity when wiring and wire all connections correctly.) DC s AC s LYN-D Note:. For the DC models, check the coil polarity when wiring and wire all connections correctly.. The indicator is red for AC and green for DC.. The operation indicator indicates the energization of the coil and does not represent contact operation. Check the coil polarity when wiring and wire all connections correctly. Check the coil polarity when wiring and wire all connections correctly. LY LYZ LYN LYZN LY-D LYZ-D LYN-D LYZN-D LY(Z) Terminal Arrangement/Internal Connections (Bottom View) LY(Z)-D. Eight, -dia. holes max. Check the coil polarity when wiring and wire all connections correctly. LY(Z)N DC s AC s LY(Z)N-D 6 max max. Note:. For the DC models, check the coil polarity when wiring and wire all connections correctly.. The indicator is red for AC and green for DC.. The operation indicator indicates the energization of the coil and does not represent contact operation. Check the coil polarity when wiring and wire all connections correctly. Check the coil polarity when wiring and wire all connections correctly.

11 LY LYN LY-D LYN-D Terminal Arrangement/Internal Connections (Bottom View) LY LY-D. max. 6. max. 6.4 Eleven, -dia. holes. max. LYN-D Check the coil polarity when wiring and wire all connections correctly. DC s LYN AC s Check the coil polarity when wiring and wire all connections correctly. Check the coil polarity when wiring and wire all connections correctly. Note:. For the DC models, check the coil polarity when wiring and wire all connections correctly.. The indicator is red for AC and green for DC.. The operation indicator indicates the energization of the coil and does not represent contact operation. LY4 LY4N LY4-D LY4N-D LY4 Terminal Arrangement/Internal Connections (Bottom View) LY4-D. max. 6 max max. Fourteen, -dia. holes Check the coil polarity when wiring and wire all connections correctly. LY4N LY4N-D DC s AC s Check the coil polarity when wiring and wire all connections correctly. Check the coil polarity when wiring and wire all connections correctly. Note:. For the DC models, check the coil polarity when wiring and wire all connections correctly.. The indicator is red for AC and green for DC.. The operation indicator indicates the energization of the coil and does not represent contact operation. LY-CR LYZ-CR LYN-CR LYZN-CR. Terminal Arrangement/Internal Connections (Bottom View) LY(Z)-CR LY(Z)N-CR Eight, -dia. holes* max. max max. CR element C =. μf R = Ω *These dimensions are for the LYN-CR.

12 LY Relays with PCB Terminals LY-, LY-, LY-, and LY4- PCB Processing Dimensions (Bottom View) pole poles poles 4 poles max.. max. 6 max. Five,.-dia. holes Note: The figures and dimensions depicted here are for the LY-. The dimension with an asterisk (*) is 6.4 for the LY-. Eight,.-dia. holes Eleven,.-dia. holes Fourteen,.-dia. h Note:. The dimensional tolerance is. mm.. There are exposed parts (conductive parts) on the LY- other than the terminals. Be careful when using this Relay on a double-sided PCBs. Terminal Arrangement/Internal Connections (Bottom View) LY- LY- LY- LY4-6 7 Case-surface mounting LYF LYF Mounting Hole Dimensions. max. Terminal Arrangement/Internal Connections (Bottom View) LYF LYF 44 max. 9 max.. max. Two,.-dia. holes or two M screw holes Eight, -dia. holes* Note: The dimensional tolerance is ±. mm. Note: The figures and dimensions depicted here are for the LYF. The LYF is also conforms to these measurements. LYF Mounting Hole Dimensions max. Terminal Arrangement/Internal Connections (Bottom View) LYF. max. 44 max. Two,. dia. holes or two M screw holes Eleven, -dia. holes 6 max. LY4F Mounting Hole Dimensions 4. max. Three,. dia. holes or two M screw holes max. Fourteen, -dia. holes Terminal Arrangement/Internal Connections (Bottom View) LY4F 44 max.. max.

13 Connection Sockets Dimensions Terminal Arrangement/ Internal Connections Mounting Hole Dimensions PTFA Two, 4. 6 mounting holes 7±. -M max..4 Two, 4. dia. or M4 mounting holes. max. max. 4 PTFA-E (Finger Protection Structure) 6±. Two, 4. 6 mounting holes -M (Top View) 9±. 7. max.. (Top View) Note: Track mounting is also possible.. max. max. PTFA Two, 4. 6 mounting holes Two, 4. 6 mounting holes 7±. -M ±. 7. max..4 7 max. max. 9 7 (Top View) 7.±. (Top View) Note: Track mounting is also possible. PTF4A Two, 4. 6 mounting holes 7±. 4-M max..4 Two, 4. dia. or M4 mounting holes 4 4. max. max. 7 6 PTF4A-E (Finger Protection Structure) Two, 4. 6 mounting holes 7±. 4-M ±. 7. max.. (Top View) 6±. (Top View) Note: Track mounting is also possible. 4. max. max. Note: If you use the PTFA, PTFA-E, or PT with an LY Relay, connect the following terminal pairs: -, -4, and -6 (for usage at A or higher).

14 Dimensions Terminal Arrangement/ Internal Connections Mounting hole and PCB dimensions PT PTQN max.. 9. max. max max.. 4 max max. max..± max. Eight,.7-dia. oblong holes PT-. * Maintain a sufficient distance from the pattern when using double-sided PCBs. The structure does not resist flux. Manual soldering is recommended for this product (Bottom View) * max max. 4. max. Eight,.-dia. holes (±. tolerance) PT PTQN... Eleven,.7-dia. holes..6 max. ±..7. max max..6 max..7 PT- 9. max.. * max. * Maintain a sufficient distance from the pattern when using double-sided PCBs. The structure does not resist flux. Manual soldering is recommended for this product. max (Bottom View) Eleven,.-dia. holes max. 9. max (±. tolerance) PT4 PT4QN... Fourteen,.7-dia. holes 4. max.. 4±..7. max. 6. max. 9. max. 4. max max. PT max. 9. max. * Maintain a sufficient distance from the pattern when using double-sided PCBs. The structure does not resist flux. Manual soldering is recommended for this product (Bottom View) * 4. max max. 6. max. 9. max. Note: Use a panel with a thickness of to mm when mounting a Socket on it. Fourteen,.-dia. holes (±. tolerance) 4

15 Hold-down Clips PYC-A Approx..4 g (per clip) One Set ( Clips) Approx. 6. PYC-P Approx..4 g Approx. 9 Approx. PYC-S Approx.. g. Y9H- Approx..7 g (per clip) One Set ( Clips) Approx. PYC- Approx. 6 g Socket Mounting Plates (t =.6) OMRON can provide Socket Mounting Plate for convenient Socket installation. Please use these Plates as required. PYP- PYP- PYP-6 49 Two,.4-dia. holes = 46.± R.7. 7, oval holes 7, oval holes = 46.±.6 ± R ± ± ± = 46.± = 46.± = 46.±.6.6 PTP-- PTP- 49 4± = 4.4±.6 4, oval holes 7.7 4±. 49 4±. 49 R Four,.4-dia. holes.4 R = 4.4± = 4.4± , square holes PTP- PTP- Four,.4-dia. holes 9 R = 444.6±.6 4, oval holes 7.7 4±. 49 R.7 4±. 49 ± = 444.6± = 444.6±

16 Connection Socket and Hold-down Clip Application Table Applicable Relay Standard models: Bifurcated contact models: operation indicators: diodes: CR circuits: Mounting Height with Sockets Front-mounting Sockets Item Front-mounting Sockets Back-mounting Sockets Number of poles Track or screw mounting PTFA PTFA PTF4A Applicable Hold-down Clips Solder terminals, wrapping terminals, or PCB terminals PT(QN) PT- PT(QN) PT- PT4(QN) PT4- or PYC-A 4 Applicable Hold-down Clips PYC-P Y9H- PYC- Back-mounting Sockets Note:. The PTF@A can be mounted on a track or with screws.. The measurements in parentheses are for the LY@-CR (built-in CR circuit). Safety Precautions Refer to the Common Relay Precautions for precautions that apply to all Relays. Precautions for Correct Use Use two M screws to attach case-surface-mounted models (LYF, LYF, LYF, and LY4F) and tighten the screws securely. (Normal tightening torque:.9 N m) For Relays with Tab Terminals, select a wire diameter for the lead wires that connect to the faston receptacle terminals that is within the allowed range for the load current. Do not impose excessive external force on the Relay when inserting the Relay to the faston receptacle or pulling the Relay out from the faston receptacle. Do not attempt to insert a terminal diagonally or insert or pull out more than one terminal at the same time. LY Single-contact Relays are for power switching applications. Do not use the LY Series for switching minute loads of ma or less, such as signals. About the Built-in Diode and CR Elements The diode or CR element that are built into the Relay are designed to absorb the reverse voltage from the Relay coil. If a large surge in voltage is applied to the diode or CR element from an external source, the element will be destroyed. If there is the possibility of large voltage surges that could be applied to the elements from an external source, take any necessary surge absorption measures. Applying A or More When Using an LY Relay with the Following Sockets When you use an LY-series relay in combination with the PTFA, PTFA-E, or PT, connect each of the following terminal pairs: () to (), () to (4), and () to (6). Relay Replacement To replace the Relay, turn OFF the power supply to the load and Relay coil sides to prevent unintended operation and possible electrical shock. Attaching and Removing Relay Hold-down Clips When you attach a Hold-down Clip to or remove it from a Socket, wear gloves or take other measures to prevent injuring your fingers on the Hold-down Clip. 6

17 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer s application or use of the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user s programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. OMRON Corporation Industrial Automation Company 7. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 7 All Right Reserved.

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G@-VD CSM_GH_GHD_DS_E_6_ New Models with International Standards Added to GH Series (-VD in model number). Same Profile as LY and LY Bi-power Relays Certified by UL, CSA, and VDE (models

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models Solid State Relays CSM DS_E_5_3 100-μA-max. Leakage Current, No Bleeder Resistor Required Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket (according to actual OMRON measurements).

More information

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_5_3 International Standards for G3F Series, Same Profile as MY Power Relays Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate Hybrid Power elay CSM DS_E_6_ Hybridization of a Magnetic elay and an SS Achieves 0-A Switching for 0 Million Operations. UL/CSA certified (-US models). Using a triac to open and close the circuit reduces

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Name No. of I/O points Model Safety inputs: 12, test outputs: 4 Safety I/O s DST1 Series CSM_DST1 Series_DS_E_7_3 Distributed Safety s That Reduce Wiring. Lineup includes four models to accommodate various I/O types and number of I/O points. Monitor the safety system

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

CSM_PYF S/P2RF- -S_DS_E_2_5

CSM_PYF S/P2RF- -S_DS_E_2_5 Screwless Clamp Terminal Sockets PYF@@S/P2RF-@@-S CSM_PYF S/P2RF- -S_DS_E_2_5 New Screwless Terminal Sockets Added for MY and G2R Relays. Simplified wiring without tightening screws. Two wires can be independently

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_2_ Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information Grooved-type with Built-in Amplifier EZ-G CSM_EZ-G_DS_E_9_ with Grooved Design and Easy Settings Groove-type with groove width of 5 mm. Models are available with one or two light axes. Models are available

More information

Model A7BS

Model A7BS Thumbwheel Switch ABS/ABL CSM_ABS/ABL_DS_E Wide Range of Locking-type s Available Character height of.8 or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001 NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O

More information

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure Indicator (Cylindrical 22/25-dia.) CSM DS_E_3_4 Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Same type as the A22-series Pushbutton Switches. Use 25-dia. ring to install in 25-dia.

More information

Model Number Structure

Model Number Structure Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_4_2 International Standards for G3F Series, Same Profile as MY Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (model numbers

More information

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model Small Spot/Mark (Separate Amplifier) EC-VS/VM CSM_EC-VS/VM_DS_E_6_ Extremely thin beam ideal for detection of minute objects and marks Ideal for detection of small objects and slight color differences

More information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units. Sensor Communications Unit CSM DS_E_1_1 The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation Low initial cost achieved by distributed

More information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21 Solid-state timer CSM DS_E_3_2 Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

Connecting Sockets, Mounting Brackets, DIN Rails

Connecting Sockets, Mounting Brackets, DIN Rails Connecting Sockets, Mounting Brackets, DIN Rails CSM_ConnectionSocket_DS_E_3_1 Durable, Easy-to-handle Connecting Sockets and Mounting Brackets Highly reliable Track-mounted and Back-connecting Sockets

More information

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs I/O Terminal Socket PTF-IS/OS/OS CSM_PTF-IS_OS_OS_DS_E I/O Terminal Sockets to Flexibly Build Systems Mount either GT I/O Relays or GTA SSRs. Compact size for both Input and Output I/O Terminal Sockets:

More information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information Cable Amplifier Proximity Sensor EEC CSM_EEC_DS_E_9_ Subminiature Sensors with Long-distance Detection Shielded Sensor Heads from -mm to M diameters that can be embedded in metal. Robotics cables provided

More information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M Chip-immune Inductive EEZ CSM_EEZ_DS_E_6_ Chip-immune Inductive Correct operation even with aluminum or iron chips sticking to the. Only the sensing object is detected. Pre-wired Smartclick Connector s

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_3_1 Easy-to-use, w-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W Axial Interface Unit CK3W-AX Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W-AX Features One CK3W-AX Unit controls up to four axes Analog input type

More information

Model NPN output PNP output Standard. configuration

Model NPN output PNP output Standard. configuration Slot-type Photomicrosensor (Non-modulated) *1 EE-SX/6 CSM_EE-SX/6_DS_E_1_ Global Standard Slot-type photomicrosensors with 0- to 100-mA direct switching capacity. Series includes that enable switching

More information

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction. All Metals and Long- Types CSM DS_E and Both Detectable from Long Distances times the aluminum detection of previous models Twice the max. Equipped with a function to prevent the detection of aluminum

More information

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications. Safety Network Controller NEA-SCPU Series CSM_NEA-SCPU_Series_DS_E Achieve Safety Control through Programming. Compact Safety Controller. The NEA-SCPU-V provides built-in safety inputs and 8 built-in safety

More information

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE SYSMAC Option CSM DS_E_2_1 The RS-232C port of the SYSMAC series can be changed into RS-422A/485 port. The connects directly to a CS/CJ-series RS-232C port and converts RS-232C to RS-422A/485. Features

More information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M Chip-immune Inductive EEZ CSM_EEZ_DS_E Chip-immune Inductive Correct operation even with aluminum or iron chips sticking to the. Only the sensing object is detected. Pre-wired Smartclick Connector s also

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_2_1 I/O SSRs That Mount to OMRON s G7TC I/O Block Input and output modules are available in wide variety. Snaps easily into P7TF I/O Terminals and can be used together with

More information

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring. CQM1 I/O CSM_CJ1W-AT4 DS_E_1_1 Easy and secure replacement by reusing the I/O terminal block wiring You can replace CQM1(H) Series with CJ Series, efficiently using your assets. Time for wiring works and

More information

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter Solid-state Timer Solid-state Timer with Variable Time Ranges Four time ranges are selectable per timer unit. Wide timing range of 0.05 second to 30 hours can be covered by a combination of five timer

More information

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort, CPU42 RUN ERR/ALM INH PRPHL/COMN OPEN MCPWR BUSY OPEN PERIPHERAL PORT (RS-232C) CS-series B7A Interface Unit CSM DS_E_3_2 It transmits 16 points of I/O signals per word with a pair of cables. Easy and

More information

Indicator (Square) Ultra Bright LED Type

Indicator (Square) Ultra Bright LED Type New Products Indicator (Square) Ultra Bright LED Type M2S Indicator Series with Square 40-mm Body. New models added with Ultra LEDs. New models with ultra bright LEDs added to singlescreen models. Previous

More information

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2. Terminal SSR G3S CSM_G3S_DS_E_7_ Compact Terminal SSR with Outputs Easy-to-use SSR block that combines four compact G3S SSRs, sockets, and heat sink in one unit. Easy wiring with separate I/O terminal

More information

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time Ground Fault Relay CSM DS_E_9_3 Economical, Compact, High-performance, DIN 8 8-mm Ground Fault Relay for Low Voltages Performs continuous monitoring and detection of ground faults in low-voltage circuits

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

E4C-UDA CSM_E4C-UDA_DS_E_12_2

E4C-UDA CSM_E4C-UDA_DS_E_12_2 Digital Amplifier Ultrasonic Sensor E4C-UDA CSM_E4C-UDA_DS_E_12_2 Compact, Cylindrical Reflective Ultrasonic Sensor with Easy Setting Stable operation for a variety of objects regardless of color, transparency,

More information

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News New Product News Probe Pin Electroplated Probe Pin for High Reliability The Probe Pin that is made of only one part. The flat structure helps you reduce the pin pitch in comparison with standard probe

More information

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC Solid State Relay G3MC Compact, Thin-profile, Low-cost SSR with Reinforced Insulation Small bottom surface area (approx. 80% of the conventional G3MB s), ideal for close PCB mounting. DC input and AC output

More information

Indicator (Square) Ultra Bright LED Type

Indicator (Square) Ultra Bright LED Type New Products Indicator (Square) Ultra Bright LED Type M2P Large Square-bodied Indicators. New models added with Ultra LEDs. New models with ultra bright LEDs added to single- models. Previous models not

More information

M16-J M16-A M16-T

M16-J M16-A M16-T Indicator (Cylindrical 16-dia.) CSM DS_E_7_2 Cylindrical 16-dia. Indicator Same basic design as the A16 Pushbutton Switch. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety

More information

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information Ultracompact 20-mm-dia. Incremental Rotary Encoder CSM DS_E_4_1 Ultracompact Rotary Encoder with External Diameter of 20 mm Incremental model External diameter of 20 mm. Resolution of up to 1,000 ppr.

More information

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs Terminal Relay/Terminal SSR G6B-@@ND/G3S CSM_G6B- ND_G3S_DS_E Compact Terminal Relays/Terminal SSRs with four outputs Easy wiring with separated input/output terminals. LED operation indicator. Mounts

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal.

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_4_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

Electroformed Probe Pins XP3A

Electroformed Probe Pins XP3A New Product Electroformed Probe Pins Electroplated Probe Pins for High Reliability The Probe Pin that is made of only one part. The flat structure helps you reduce the pin pitch in comparison with standard

More information

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor Portable Power Monitor ZN-CTX/-CTM CSM_ZN-CTX_-CTM_DS_E 2 Easy and Quick Checking Power at the Worksite Display and record power consumption without stopping the power supply. Battery driven, mounted with

More information

NPN output. 200 mm. Type Cable length Model Remarks

NPN output. 200 mm. Type Cable length Model Remarks Retroreflective Photomicrosensor with Lens CSM DS_E_5_2 Photomicrosensor with light modulation for reduced external light interference. Easy adjustment and optical axis monitoring with a light indicator.

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

Dimension A. Dimension B

Dimension A. Dimension B Slim Connector-Terminal lock Conversion Units CSM DS_E_2_3 New Slim Connector-Terminal lock Conversion Units. Mounting area reduced by 35% (in comparison with 40-pole XW2 Units) to contribute to downsizing

More information

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC Solid-state Timer CSM DS_E_4_1 Miniature Timer Compatible with the MY Relay Semi-multi power supply voltage. Large transparent time setting knob facilitates time setting. A flat-blade and Phillips screwdriver

More information

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4.

Reliable Detection Unaffected by PCB Holes or Notches. PCB Sensors. Ordering Information. Sensors [Refer to Dimensions on page 4. PCB Sensors ES-LS@ CSM_ES-LS DS_E_5_2 Reliable Detection Unaffected by PCB Holes or Notches High-limit ES-LS@ is suitable for incorporation in devices. Wide-range ES-LS@W is ideal for detecting tall components

More information

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure

D5B. Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics. Mechanical Touch Switch. Model Number Structure Mechanical Touch Switch D5B CSM_D5B_DS_E_3_2 Detects Objects in Multiple Directions with High Sensitivity, Ideal for Robotics Slow-action switching mechanism used. Gold-plated contact with coil spring

More information

E2K-X4ME1 2M E2K-X4ME2 2M

E2K-X4ME1 2M E2K-X4ME2 2M Cylindrical Proximity Sensor EK- CSM_EK-_DS_E 1 General-purpose Threaded Sensor That Detects Metals and Non-metals Alike Detects both metallic and nonmetallic objects (water, oil, glass, plastic, etc.).

More information

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0.

Power supply voltage Output configuration Output phases Resolution (pulses/rotation) Model. 100, 200, 360 E6A2-CWZ5C (resolution) 0. Incremental 25-mm-dia. Rotary Encoder CSM DS_E_5_1 Compact Encoder with External Diameter of 25 mm Incremental model External diameter of 25 mm. Resolution of up to ppr. Be sure to read Safety Precautions

More information

Model Number Structure

Model Number Structure Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller with analogue setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2 Thumbwheel Switch ABS/ABL CSM_ABS_ABL_DS_E Wide Range of Locking-type s Available Character height of. or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals. CS-series Net Unit CSM DS_E_5_3 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures

More information

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input)

3. Input KJ: Thermocouple P: Platinum resistance thermometer T: Thermocouple/platinum resistance thermometer (universal-input) Temperature Controllers CSM DS_E Easy Setting Using DIP Switch and Simple Functions in DIN mm-size Temperature Controllers Easy setting using DIP switch. s with two alarms added to Series, ideal for temperature

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm Digital Amplifier Ultrasonic Sensor CSM DS_E_1_1 A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Compact with a Broad Selection of Side-view Heads Slim with analog outputs

More information

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Aluminum-detecting Proximity Sensor (Separate Amplifier Type) Aluminum-detecting Proximity Sensor (Separate Amplifier Type) ECY Simple Teaching Function for Simple Adjustment. Easy-to-see Excess Gain Level Indicators. Detects aluminum, copper, and other non-ferrous

More information

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output Solid-state Timer H3FA Please read and understand this catalog before purchasing the products. Please consult OMRON representative if you have any questions or comments. Refer to Warranty and Application

More information

NX-TS. NX-series Temperature Input Unit

NX-TS. NX-series Temperature Input Unit NX-series Temperature Input Unit NX-TS CSM_NX-TS_DS_E_1_1 Temperature Input Units for Low-speed and High-speed*, High-precision* Temperature Control in Combination with NJ Series NX-series Temperature

More information

Classification Applicable models Specification Type Model

Classification Applicable models Specification Type Model Connect Terminal Box (Muting Terminals) F39-TC5 CSM_F39-TC5_DS_E_4_1 Significantly reduces amount of wiring between Safety Light Curtains and Muting Senss. As of August 2008 Provides IP67 protection against

More information

D4GS-N CSM_D4GS-N_DS_E_7_4

D4GS-N CSM_D4GS-N_DS_E_7_4 Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_4 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear

More information

Model Number Structure

Model Number Structure Total Counter/Time Counter (DIN 8 x ) CSM DS_E DIN 8 x -mm Total Counter/Time Counter with Easy-to-read Displays and Water and Oil Resistance Equivalent to IP66 High-visibility, negative transmissive LCD

More information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4 40 XW2B-40G5 *1 50 XW2B-50G5 60 XW2B-60G5 40 XW2B-40G5-T Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor.

EE-SX97 40% Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. Slot-type Photomicrosensor. Slot-type Photomicrosensor EE-SX CSM_EE-SX_DS_E Built-in connector enables downsizing and easier connection. Protective circuit for safe operation. A built-in connector minimizes the shape and dimensional

More information

Model Number Structure

Model Number Structure Solid-state Twin Timers CSM DS_E_1_5 DIN 48 48-mm Twin Timers Wide power supply ranges of 100 to 240 VAC and 48 to 125 VDC respectively. ON- and OFF-times can be set independently and so combinations of

More information

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit

Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor E2J-W10MA 1M E2J-W20MA 1M. E2J-JC4A Amplifier Unit Long Sensing-distance Capacitive Separate Amplifier Proximity Sensor Flat Capacitive Sensor with Separate Amplifier Ideal for Mounting on Robot Hands. Flat head is only 5.5-mm thick. Robotics cable ensures

More information

Knob-type Selector Switches

Knob-type Selector Switches New Product Knob-type Selector Switches ANS/ANW Selector Switches with -mm Diameters. Universal Design That Emphasizes Color Coding, Workability, and Safety Easy to Use You can connect up to three Switch

More information

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor Industrial PC Platform NY-series Industrial Monitor CSM DS_E_2_2 Very stylish, very industrial Our new industrial-quality touchscreen monitors are good-looking but more importantly they also enable the

More information

Model Rectangular Square Round. Solder terminals A165K-J Series A165K-A Series A165K-T Series. (2) Number of Notches/Resetting Method

Model Rectangular Square Round. Solder terminals A165K-J Series A165K-A Series A165K-T Series. (2) Number of Notches/Resetting Method Key-type Selector Switch (Detachable) (Cylindrical 16-dia.) A165K CSM_A165K_DS_E_3_4 Separate Construction with Cylindrical 16-dia. Body Short mounting depth, less than 28.5 mm below panel Wide range of

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_2_1 Easy-to-use, w-cost Digital Panel Meter that Accepts AC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. ghly visible display

More information

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure

G9SA. Safety Relay Unit. The G9SA Series Offers a Complete Line-up of Compact Units. Model Number Structure Safety Relay Unit G9 CSM_G9_DS_E The G9 Series Offers a Complete Line-up of Compact Units. Four kinds of -mm wide Units are available: A -pole model, a -pole model, and models with poles and OFF-delay

More information

Model Number Structure

Model Number Structure Solid State Relays CSM DS_E_3_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Model NPN output PNP output Standard. configuration

Model NPN output PNP output Standard. configuration Slot-type Photomicrosensor (Non-modulated) *1 EE-SX4/6 CSM_EE-SX4_6_DS_E 1 Global Standard Slot-type photomicrosensors with 0- to 100-mA direct switching capacity. Series includes models that enable switching

More information

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information

EE-SX77/87. Slim, Compact Photomicrosensor that is still easy to use. Photomicrosensor with Slim Cable (Non-modulated) Ordering Information Photomicrosensor with Slim Cable (Non-modulated) EE-SX77/87 CSM_EE-SX77_87_DS_E_7_2 Slim, Compact Photomicrosensor that is still easy to use. Compact, thin profile enables dense mounting. Indicator is

More information

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature NJ-series NJ501 SECS/GEM CPU Unit NJ501-1340 CSM_NJ501-1340_DS_E_3_1 Allows SECS/GEM communications in a short time with a simple configuration. The NJ501 SECS/GEM CPU Unit is a NJ-series machine automation

More information

Model Number Structure

Model Number Structure Temperature Controller CSM DS_E_5_1 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting Compact, low-cost Temperature Controller. Incorporates proportional control and reset adjustment function.

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M Chip-immune Inductive EEZ CSM_EEZ_DS_E Chip-immune Inductive Correct operation even with aluminum or iron chips sticking to the. Only the sensing object is detected. Pre-wired Smartclick Connector s also

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously

More information

Handheld Reader Writer

Handheld Reader Writer Handheld Reader Writer CH1D-V2 A Compact Lightweight Easy-to-use Pen-type Reader Writer. Connects directly to a personal computer or PLC via RS-232C. The Reader Writer s protective construction is IP63

More information

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch.

M16. Cylindrical 16-dia. Indicator. Indicator (Cylindrical 16-dia.) List of Models. Same basic design as the A16 Pushbutton Switch. Indicator (Cylindrical 16-dia.) CSM DS_E_6_1 Cylindrical 16-dia. Indicator Same basic design as the A16 Pushbutton Switch. Refer to Safety Precautions for All Pushbutton Switches and Safety Precautions

More information

Smart Sensors with Ultra-High-Speed Color CCD Cameras mm to mm (variable) mm to mm (variable)

Smart Sensors with Ultra-High-Speed Color CCD Cameras mm to mm (variable) mm to mm (variable) Smart Sensors with Ultra-High-Speed Color CCD Cameras ZFV-C CSM_ZFV-C_DS_E_1_2 Simple to use. Detection abilities close to human vision. One-touch automatic setting for stable detection 2.2-inch monitor

More information

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE Solid State Relay G3NE Compact, Low-cost, SSR Switching 5to20A D Wide load voltage range: 75 to 264 VAC. D Dedicated, compact aluminum PCB and power elements used. D Built-in varistor effectively absorbs

More information

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC

Reverse Protection Relay 2. Control Power Supply Voltage None: 200/220 VAC 380: 380/400 VAC 440: 440 VAC Reverse Protection Relay CS DS_E Uses Voltage Detection to Determine Reverse Revolution of Three-phase otor Detects motor reversal due to incorrect wiring. Direction of motor revolution is detected as

More information

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated

Output configuration Contact form Operation indicator Cable length Model PNP open collector. 1 m D5F-2B10 (+ common) ON when operated High-precision Optical Switch D5F CSM_D5F_DS_E_2_2 Optical System Achieves 1-μm Operating Position Repeatability in this 4-way Switch No-contact structure for high reliability. Ceramic materials in measuring

More information