DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Calif Fax Est.

Size: px
Start display at page:

Download "DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Calif Fax Est."

Transcription

1 DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Calif Fax Est User Manual PCI2PMC PCI Single Slot PMC Compatible Carrier Use Your PMC in a PC Manual Revision L2 Corresponding Hardware: Revision L

2 PCI2PMC PCI and PMC Compatible Carrier Dynamic Engineering 150 DuBois St. Suite C Santa Cruz, CA FAX This document contains information of proprietary interest to Dynamic Engineering. It has been supplied in confidence and the recipient, by accepting this material, agrees that the subject matter will not be copied or reproduced, in whole or in part, nor its contents revealed in any manner or to any person except to meet the purpose for which it was delivered. Dynamic Engineering has made every effort to ensure that this manual is accurate and complete. Still, the company reserves the right to make improvements or changes in the product described in this document at any time and without notice. Furthermore, Dynamic Engineering assumes no liability arising out of the application or use of the device described herein. The electronic equipment described herein generates, uses, and can radiate radio frequency energy. Operation of this equipment in a residential area is likely to cause radio interference, in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference by Dynamic Engineering. Other trademarks and registered trademarks are owned by their respective manufactures. Manual Revision H1. Revised January 20, 2010 Dynamic Engineering s products are not authorized for use as critical components in life support devices or systems without the express written approval of the president of Dynamic Engineering. Connection of incompatible hardware is likely to cause serious damage. Embedded Solutions Page 2

3 Table of Contents PRODUCT DESCRIPTION 5 USAGE NOTES: 6 Notes: 8 PMC MODULE BACKPLANE IO INTERFACE PIN ASSIGNMENT 9 APPLICATIONS GUIDE 10 Interfacing 10 Construction and Reliability 11 Thermal Considerations 11 WARRANTY AND REPAIR 12 Service Policy 12 Out of Warranty Repairs 12 For Service Contact: Customer Service Department Dynamic Engineering 12 SPECIFICATIONS 13 ORDER INFORMATION 14 Embedded Solutions Page 3

4 List of Figures FIGURE 1 PCI2PMC PN4 INTERFACE STANDARD 9 Embedded Solutions Page 4

5 Product Description PCI2PMC is part of the PCI and PMC Compatible family of modular I/O components. The PC2PMC adapts one PMC to one PCI slot. Dynamic Engineering has several versions of the PCI2PMC including bridged and two slot versions. The PCI2PMC is a single slot passive design. Special features: Universal PCI 1/2 length card. LED s are green and steady on when the voltages are active. LED1 is PMC Busmode Present LED2 is 3.3V to PMC LED3 is 3.3 from PCI bus. LED4 is 3.3 from Regulator LED5 is plus 5 LED6 is plus 12 LED7 is minus 12 Jumper selection for onboard 1500mA regulator or PCI 3.3V supply 32 or 64 bit operation 10 ohm series resistors on AD31-0 Clamping Diodes on critical PCI signals Zero delay buffer for PCI clock distribution PrPMC clocking options Front panel connector access through PCI bracket User IO [Pn4] available through 2 cable connectors (DIN IDC and SCSI II compatible) Spare pins on SCSI connector can be jumper selected to 5V or ground. Matched length IO. Cooling cutout for increased airflow to PMC Jumper selection on M66EN JTAG and Monarch mode control header options PCI2PMC is a passive design incurring no added delays in connection from the PCI to the PMC buses. The design incorporates features to prevent the physical length of the traces from affecting operation. There may be cases where the backplane can t support all slots with PCI2PMC cards installed. Our bridged products including PCIBPMC, PCIBPMCET, PCIBPMCX1, and PCIBPMCX2 can be used in situations where a bridge is desired. Please refer to the Dynamic Engineering website for more information on these and other products. Embedded Solutions Page 5

6 Usage Notes: The regulator LED may not illuminate unless there is a load from the PMC on the 3.3V supply, and the regulator is selected as the power source for the 3.3V. The Regulator path can provide up to 1500 ma of 3.3V power. Two FET s are used to allow the user to select PCI 3.3V or local regulator as the source for the 3.3V power to the PMC. If the PMC uses more than 1.5A the PCI selection must be made. When the PCI path is selected the current flows almost unimpeded from the PCI connector to the PMC connector. Two high current FET s are used in series to switch the power source with low impedance losses. Jumper options are clearly marked in the component side silk screen. J1 3.3V Source selector. 1-2 = regulated, 2-3 = PCI source open = float 3.3V J2 Connected to pins 33, 67 on P = 5V, 2-3 = GND installed with SCSI J3 Connected to pins 34, 68 on P = 5V, 2-3 = GND installed with -SCSI J4 Connected to M66EN. Installed = GND = 33 MHz. Open = bus condition = 33 or 66 MHz. J5 is the JTAG Header with options for connection to PCI bus or from Flying leads. Installed with -JTAG PCI Side PMC Side TRST# 1 2 TCK 3 4 TMS 5 6 TDI 7 8 TDO 9 10 The header can be jumpered across to connect the PCI side to the PMC side or the PMC side can be connected to flying leads from your JTAG interface. J8 Pin 1 = 3.3, and pin 2 = gnd used for reference with JTAG Add JTAG to the Part Number if you need J5 and J8 installed. Embedded Solutions Page 6

7 J6 and J7 control the PrPMC clock options. Installed with M option. J6 J7 OPN OPN SHNT SHNT SHNT OPN OPN SHNT PCI CLK VIA PLL TO PMC standard non M signal path. OSC TO BP & PMC BIPASS PLL OSC TO BP & PMC USING PLL PMC DRIVING CLOCK TO BP J9 is installed when the M option is requested. J9 is a two pin header. When a shunt is installed the 1KΩ resistor provides a pull-down. When open a 10KΩ resistor provides the pull-up. The installed PrPMC can usually override either setting after power-up using software. J10 controls the grounding options for the PCI bezel. 1-2 is an AC coupled connection via.1uf cap. 2-3 is DC connection to ground. Open is not connected to ground. J11 controls the grounding options for the PMC bezel. 1-2 is an AC coupled connection via.1uf cap. 2-3 is DC connection to ground. Open is not connected to ground. PCI2PMC is a product consisting of a PCB and added components. The components can be swapped or left off to create different versions. The standard version of the board is called PCI2PMC and comes with a complete 64 bit PCI path to support 32 and / or 64 bit operation at 33 and / or 66 MHz. The PMC may have IO through its bezel or via Pn4 or both. The Bezel IO is supported via the PCI rear IO port. The Pn4 IO is supported with either a DIN or SCSI connector. The DIN connector is standard and the SCSI option swaps the DIN for the SCSI. The PCI2PMC ME version removes the Upper part of the PCI bus and the rear IO leaving the primary 32 bit PCI path and PMC Bezel IO. This version is usually provided with the HC option to remove the regulator and FET s etc. to provide a hardwired PCI 3.3V sourced board. PCI2PMC, PCI2PMC-SCSI, and PCI2PMC-ME-HC are stocked items. Other combinations are built to order. Please see the last page for more ordering options. Embedded Solutions Page 7

8 Notes: A) Revision 4 and later boards M66EN is connected to the PMC slot [Jn2-47]. Recent revision 3 boards are reworked to have the equivalent functionality. B) Shunts are capable of 800 ma. The Shunts on J2,J3 are not fuse protected. Your circuit must limit total power consumed. C) Rev 1-4 required HC option for more than 800 ma of 3.3V from the backplane to be routed to the PMC. Revision 5 and later have MOSFET switches controlled by J1 with a 10A rating. The local regulator has been upgraded to 1500 ma. D) Revision 5 and later boards with the PrPMC option; not installed unless ordered. Standard configuration is the equivalent of the PCI clock through the PLL to the PMC. E) Rev 5 and later boards have power reference for JTAG header. F) Rev 7 switched to 0603 capacitors and increased quantity G) Rev 8 has matched length IO for Pn4. H) Manufacturability update I) Redesigned PCI 3.3 power circuit to use dual FET s instead of diode and FET. J) Add Bezel Grounding options, update to 0402 components, K) Move 2 and 3 pin headers for better use. L) Manufacturability update : adjust 0402 pads Embedded Solutions Page 8

9 PMC Module Backplane IO Interface Pin Assignment The figure below gives the pin assignments for the PMC Module IO Interface from Pn4 to the PCI2PMC connectors. Also see the User Manual for your PMC board for more information. DIN IDC [P3] SCSI II [P2] Pn4 C1 A C2 A C3 A C4 A C5 A C6 A C7 A C8 A C9 A C10 A C11 A C12 A C13 A C14 A C15 A C16 A C17 A C18 A C19 A C20 A C21 A C22 A C23 A C24 A C25 A C26 A C27 A C28 A C29 A C30 A C31 A C32 A Open, +5 or GND via J2 silk screen defined Open, +5 or GND via J3 FIGURE 1 PCI2PMC PN4 INTERFACE STANDARD Read table: P3-C1 = P2-1 = Pn4-1 P3-A1 = P2-35 = Pn4-2 etc. Embedded Solutions Page 9

10 Applications Guide Interfacing Some general interfacing guidelines are presented below. Do not hesitate to contact the factory if you need more assistance. Installation The PMC is mounted to the PCI2PMC prior to installation within the chassis. For best results: with the PCI bracket installed, install the PMC at an angle so that the PMC front panel bezel penetrates the PCI bracket then rotate down to mate with the PMC [JnX - PnX] connectors. If the PCI bracket is not installed, plug in the PMC and then attach the PCI bracket. Use the mounting screws that come with the PMC to secure to the PCI2PMC. There are four mounting locations. Two into the PMC mounting bezel and two for the standoffs near the PMC bus connectors. Start-up Make sure that the "system" can see your hardware before trying to access it. Many BIOS will display the PCI devices found at boot up on a "splash screen" with the VendorID and CardId for the PMC installed and an interrupt level. Watch the system grounds. All electrically connected equipment should have a failsafe common ground that is large enough to handle all current loads without affecting noise immunity. Power supplies and power consuming loads should all have their own ground wires back to a common point. Power all system power supplies from one switch. Connecting external voltage to the PCI2PMC when it is not powered can damage it, as well as the rest of the host system. This problem may be avoided by turning all power supplies on and off at the same time. This applies more to the PMC installed into the PCI2PMC than the PCI2PMC itself, and it is smart system design when it can be achieved. Embedded Solutions Page 1 0

11 Construction and Reliability PMC Modules were conceived and engineered for rugged industrial environments. The PCI2PMC is constructed out of inch thick High Temp FR4 material. The material is UL recognized per 94V-0. ROHS and non-rohs assemblies are available. A cooling cutout has been designed into the product for improved airflow to the PMC. The components on the PCI2PMC are passive and do not generate an appreciable thermal load. Surface mounted components are used. The connectors are SMT for the PMC bus and through hole for the IO. The PMC Module connectors are keyed and shrouded. They are rated at 1 Amp per pin, 100 insertion cycles minimum. These connectors make consistent, correct insertion easy and reliable. The PMC Module is secured against the carrier with the PMC connectors. It is recommended, for enhanced security against vibration, that the PMC mounting screws are installed. The screws are supplied with the PMC from the OEM. Dynamic Engineering has screws, standoffs, blank bezels and other PMC hardware available at a reasonable cost if your PMC was not shipped with some of the require attachment hardware or if it has been misplaced. Thermal Considerations The PCI2PMC design consists of passive circuits. The power dissipation due to internal circuitry is very low. If the PMC installed has high heat dissipation; forced air is recommended. The PCIBPMC() series has fan capability. If your PMC is hot please consider the bridged carriers and choose a FAN option to keep your hardware cool. Alternatively your PC may have sufficient air movement within the chassis to use the passive cooling designed into the PCI2PMC. Embedded Solutions Page 1 1

12 Warranty and Repair Please refer to the warranty page on our website for the current warranty offered and options. Service Policy Before returning a product for repair, verify as well as possible that the suspected unit is at fault. Then call the Customer Service Department for a RETURN MATERIAL AUTHORIZATION (RMA) number. Carefully package the unit, in the original shipping carton if this is available, and ship prepaid and insured with the RMA number clearly written on the outside of the package. Include a return address and the telephone number of a technical contact. For out-of-warranty repairs, a purchase order for repair charges must accompany the return. Dynamic Engineering will not be responsible for damages due to improper packaging of returned items. For service on Dynamic Engineering Products not purchased directly from Dynamic Engineering contact your reseller. Products returned to Dynamic Engineering for repair by other than the original customer will be treated as out-of-warranty. Out of Warranty Repairs Out of warranty repairs will be billed on a material and labor basis. The current minimum repair charge is $150. Customer approval will be obtained before repairing any item if the repair charges will exceed one half of the quantity one list price for that unit. Return transportation and insurance will be billed as part of the repair and is in addition to the minimum charge. For Service Contact: Customer Service Department Dynamic Engineering 150 DuBois St. Suite C Santa Cruz, CA fax InterNet Address support@dyneng.com Embedded Solutions Page 1 2

13 Specifications Logic Interfaces: PCI Interface 33/32 ó 66/64 Access types: CLK rates supported: Software Interface: Initialization: PCI bus accesses 33 or 66 MHz PCI clock rates direct access to PMC jumper selections for 3.3V power source, PrPMC support and cable options, PCI Bus Speed Interface: Dimensions: Construction: PMC front bezel via PCI bracket and User IO connector via DIN and or SCSI II/III connector. SCSI connector is matched length routed from Pn4. DIN is matched per side with a small offset between the sides. Column A is matched and Column C is matched. 1/2 length PCI board. High Temp FR4 Multi-Layer Printed Circuit, Through Hole and Surface Mount Components. Embedded Solutions Page 1 3

14 Order Information Base options shown. Please refer to the website for more options. standard temperature range 40ó +85 ø C PCI2PMC 1/2 length PCI card with PMC position and most popular options. IO connector, 3.3V regulator and source selector, all PMC connectors, DIN rear IO. -SCSI PCI2PMC-ME-HC -HC -M(33,66) -JTAG -ROHS Add SCSI connector instead of DIN Optimized for 32 bit operation with high current option. No rear IO on this model. Lower price point. Add high current option Any version board with PrPMC clocking options added. Any version board with JTAG header added Add ROHS processing. -CC Add conformal Coating Embedded Solutions Page 1 4

15 HDEterm68 HDEcabl68 DINterm64 DINribn pin SCSI II to 68 screw terminal converter with DIN rail mounting pin SCSI II cable with multiple length and termination options. Mates with PCI2PMC-SCSI and HDEterm pin DIN connector rows A&C to 64 screw terminal converter with DIN rail mounting. Option for testpoints instead of screw terminal pin Ribbon cable with multiple length and termination options. Mates with PCI2PMC and DINterm64. All information provided is Copyright Dynamic Engineering Embedded Solutions Page 1 5

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Calif Fax Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Calif Fax Est. DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Calif. 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PCI2PMC PCI Single Slot PMC Compatible Carrier

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual c P C I 2 P M C cpci 1 Slot PMC Compatible Carrier

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA Fax Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA Fax Est. DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual cpcibpmc3u64et cpci 3U 4HP 1 Slot PMC Compatible

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA Fax Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA Fax Est. DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual cpcirepeat32 cpci 6U 4HP PMC Carrier With PCI Bus

More information

DYNAMIC ENGINEERING. 150 DuBois St. #3, Santa Cruz Ca Fax Est

DYNAMIC ENGINEERING. 150 DuBois St. #3, Santa Cruz Ca Fax Est DYNAMIC ENGINEERING 150 DuBois St. #3, Santa Cruz Ca. 95060 831-457-8891 Fax 831-457-4793 sales@dyneng.com www.dyneng.com Est. 1988 User Manual PC104p2PMC Alternate Name: PCI1042PMC Adapt a 32 bit PMC

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca Fax Est

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca Fax Est DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz Ca. 95060 831-457-8891 Fax 831-457-4793 sales@dyneng.com www.dyneng.com Est. 1988 User Manual CPCI-J2-SCSI CPCI User IO for 3U J2 SCSI connector Rear

More information

DYNAMIC ENGINEERING 150 Dubois St. Suite C, Santa Cruz, CA Fax Est.

DYNAMIC ENGINEERING 150 Dubois St. Suite C, Santa Cruz, CA Fax Est. DYNAMIC ENGINEERING 150 Dubois St. Suite C, Santa Cruz, CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PCIe8LXMCX1 PCIe 8 Lane XMC Compatible Carrier

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Stand-Alone-Relay S-A-Relay

Stand-Alone-Relay S-A-Relay DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 sales@dyneng.com www.dyneng.com Est. 1988 User Manual Stand-Alone-Relay S-A-Relay Revision A Corresponding Hardware:

More information

The bridge insures that multiple PCIBPMC cards can be installed onto the same PCI bus stub.

The bridge insures that multiple PCIBPMC cards can be installed onto the same PCI bus stub. DE Store Home Company Search Design MadeInUSA White Papers PCIBPMC now "ET" extended temperature standard PCI to PMC Adapter / Carrier PCIBPMC Bridge based PCI and PMC Compatible Adapter Carrier Front

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Ca Fax Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Ca Fax Est. DYNAMIC ENGINEERING 150 DuBois St. Suite 3, Santa Cruz, Ca 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PMC-PARALLEL-TTL Digital Parallel Interface PMC

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, CA Fax Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, CA Fax Est. DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PMC-Wizard Two-Channel Wizard Interface Revision

More information

IP-Unidig-E Line Input/Output with LineSafe ESD Protection IndustryPack User s Manual

IP-Unidig-E Line Input/Output with LineSafe ESD Protection IndustryPack User s Manual IP-Unidig-E-48 48 Line Input/Output with LineSafe ESD Protection IndustryPack User s Manual Manual Revision: 3 7/28/99 Hardware Revision: B IP-Unidig-E-48 (415) 327-3808 FAX 48 Line Input/Output with LineSafe

More information

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PMC-PARALLEL-IO "pario" Digital Parallel Interface

More information

PMC-BiSerial-III SDLC 8-Channel SDLC Interface

PMC-BiSerial-III SDLC 8-Channel SDLC Interface DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 Software User s Guide (Linux) PMC-BiSerial-III SDLC 8-Channel

More information

PCIeBiSerial-L3com1 One-Channel Half Duplex Interface

PCIeBiSerial-L3com1 One-Channel Half Duplex Interface DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 Software User s Guide (Linux) PCIeBiSerial-L3com1 One-Channel

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz, CA FAX Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz, CA FAX   Est. DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz, CA 95060 831-457-8891 831-457-4793 FAX http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual IndustryPack-CompactFLASH IP-CF CompactFLASHtm

More information

IP-Pulse 4 Channel Digital Pulse Generator IP Module

IP-Pulse 4 Channel Digital Pulse Generator IP Module DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual IP-Pulse 4 Channel Digital Pulse Generator IP Module

More information

IP-QuadUART-485-PLRA

IP-QuadUART-485-PLRA DYNAMIC ENGINEERING 150 DuBois, Suite C, Santa Cruz, CA. 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual IP-QuadUART-485-PLRA IP Module Party Line Receiver

More information

MPP1700 User s Manual

MPP1700 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

TPCE260. PCI Express PMC Carrier. Version 1.0. User Manual. Issue August 2014

TPCE260. PCI Express PMC Carrier. Version 1.0. User Manual. Issue August 2014 The Embedded I/O Company TPCE260 PCI Express PMC Carrier Version 1.0 User Manual Issue 1.0.1 August 2014 TEWS TECHNOLOGIES GmbH Am Bahnhof 7 25469 Halstenbek, Germany Phone: +49 (0) 4101 4058 0 Fax: +49

More information

User Manual PMC-4U-CACI. Quad UART - Dual Synchronous Serial Data Interface PMC Module

User Manual PMC-4U-CACI. Quad UART - Dual Synchronous Serial Data Interface PMC Module DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 sales@dyneng.com www.dyneng.com Est. 1988 User Manual PMC-4U-CACI Quad UART - Dual Synchronous Serial Data Interface

More information

PMC-BiSerial-III SDLC

PMC-BiSerial-III SDLC DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA 95060 (831) 457-8891, Fax: (831) 457-4793 www.dyneng.com sales@dyneng.com Est. 1988 User Manual PMC-BiSerial-III SDLC 8 channel SDLC Interface PMC

More information

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 sales@dyneng.com www.dyneng.com Est. 1988 User Manual PMC BiSerial-II PS2 4 channel Bi-directional Serial Data Interface

More information

GSC-PCI TO PMC ADAPTER

GSC-PCI TO PMC ADAPTER Rev: 012605 GSC-PCI TO PMC ADAPTER PRODUCT MANUAL Copyright (C) 1999 General Standards Corp. Additional copies of this manual or other General Standards Co. literature may be obtained from: General Standards

More information

DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA (831) Fax (831) Est

DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA (831) Fax (831) Est DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA 95060 (831) 457-8891 Fax (831) 457-4793 www.dyneng.com sales@dyneng.com Est. 1988 alt_atp Linux Device Driver Documentation Revision A Corresponding

More information

Dynamic Engineering. cpci Product Line. Complete product data and manuals are available on our website.

Dynamic Engineering. cpci Product Line. Complete product data and manuals are available on our website. Dynamic Engineering cpci Product Line Complete product data and manuals are available on our website. http://www.dyneng.com/cpci.html Dynamic Engineering enjoys a sterling reputation as a result of providing

More information

PCI-ASCB Avionics Bus Tester

PCI-ASCB Avionics Bus Tester DYNAMIC ENGINEERING 150 DuBois St., Suite C, Santa Cruz, CA. 95060 831-457-8891, Fax 831-457-4793 sales@dyneng.com www.dyneng.com Est. 1988 User Manual PCI-ASCB Avionics Bus Tester 2-channel Bi-directional

More information

DYNAMIC ENGINEERING 150 DuBois St Suite Fax Est User Manual.

DYNAMIC ENGINEERING 150 DuBois St Suite Fax Est User Manual. DYNAMIC ENGINEERING 150 DuBois St Suite 3 831-457-8891 Fax 831-457-4793 sales@dyneng.com www.dyneng.com Est. 1988 User Manual PMC-BiSerial-BAE1 Real Time Clock Data Interface PMC Module Revision A2 Corresponding

More information

DYNAMIC ENGINEERING 150 DuBois Suite C Santa Cruz, CA (831) Fax (831) Est.

DYNAMIC ENGINEERING 150 DuBois Suite C Santa Cruz, CA (831) Fax (831) Est. DYNAMIC ENGINEERING 150 DuBois Suite C Santa Cruz, CA. 95060 (831) 457-8891 Fax (831) 457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 ip_gen Linux Driver Documentation Revision A ip_gen Linux

More information

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est

DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif Fax Est DYNAMIC ENGINEERING 435 Park Dr., Ben Lomond, Calif. 95005 831-336-8891 Fax 831-336-3840 www.dyneng.com sales@dyneng.com Est. 1988 User Manual PMC-BiSerial Version PS1 Bi-directional Serial Data Interface

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz, CA Fax Est

DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz, CA Fax Est DYNAMIC ENGINEERING 150 DuBois St. Suite C Santa Cruz, CA 95060 831-457-8891 Fax 831-457-4793 sales@dyneng.com www.dyneng.com Est. 1988 User Manual IP-1553 MIL-STD-1553 Interface 1 or 2 Dual Redundant

More information

PSA200 User s Manual

PSA200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite Fax Est User Manual.

DYNAMIC ENGINEERING 150 DuBois St. Suite Fax Est User Manual. DYNAMIC ENGINEERING 150 DuBois St. Suite 3 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PCI-Harpoon Revision A4 Corresponding Hardware: Revision A/B Fab number:10-2007-0601/2

More information

Sensoray Model 623 PC/104+ to PCI Adapter. Revised December 19, Sensoray Model 623 Instruction Manual 1

Sensoray Model 623 PC/104+ to PCI Adapter. Revised December 19, Sensoray Model 623 Instruction Manual 1 Sensoray Model 623 PC/104+ to PCI Adapter Revised December 19, 2003 Sensoray Model 623 Instruction Manual 1 TABLE OF CONTENTS LIMITED WARRANTY... 3 SPECIAL HANDLING INSTRUCTIONS... 3 1. INTRODUCTION...

More information

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001 INSTRUCTION MANUAL Sensoray Model 720RB/DIN Relay I/O Board (Rev A) October 12, 2001 For Technical Support contact Sensoray Co., Inc. 7313 SW Tech Center Dr., Tigard, Oregon 97223, USA Tel:(503) 684-8005

More information

APMC4110 POWERED PMC CARRIER STANDALONE PCI INTERFACE MODULE

APMC4110 POWERED PMC CARRIER STANDALONE PCI INTERFACE MODULE APMC4110 POWERED PMC CARRIER STANDALONE PCI INTERFACE MODULE USER S MANUAL ACROMAG INCORPORATED Tel: (248) 295-0310 30765 South Wixom Road Fax: (248) 624-9234 P.O. BOX 437 Wixom, MI 48393-7037 U.S.A. Copyright

More information

MPP200 User s Manual

MPP200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, CA Fax Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, CA Fax Est. DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 PCIeBiSerialDb37-LM9 Linux Driver lm9_base & lm9_chan Linux

More information

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009 Reference Manual DOC. REV. 4/29/2009 EPM-PS1 PC/104-Plus Power Supply Module WWW.VERSALOGIC.COM 12100 SW Tualatin Road Tualatin, OR 97062-7341 (503) 747-2261 Fax (971) 224-4708 Contents Copyright 2013

More information

DYNAMIC ENGINEERING 150 DuBois St., Suite C Santa Cruz, CA (831) Fax (831) Est.

DYNAMIC ENGINEERING 150 DuBois St., Suite C Santa Cruz, CA (831) Fax (831) Est. DYNAMIC ENGINEERING 150 DuBois St., Suite C Santa Cruz, CA 95060 (831) 457-8891 Fax (831) 457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual ccpmc-hotlink-ap1 Conduction-Cooled Single-Channel

More information

Sensoray Model 627 CompactPCI to PCI Adapter

Sensoray Model 627 CompactPCI to PCI Adapter Sensoray Model 627 CompactPCI to PCI Adapter Revised December 19, 2003 TABLE OF CONTENTS LIMITED WARRANTY... 4 SPECIAL HANDLING INSTRUCTIONS... 4 1. INTRODUCTION... 5 2. SYSTEM REQUIREMENTS... 5 3. SPECIFICATIONS...

More information

RACEway Products. RACEway Test Adapter (RTA-S-2 & RTA-D-2) User s Manual RevB

RACEway Products. RACEway Test Adapter (RTA-S-2 & RTA-D-2) User s Manual RevB RACEway Products RACEway Test Adapter (RTA-S-2 & RTA-D-2) User s Manual RevB TEK/TM-307B June 2000 TEK Microsystems has made every effort to ensure that this manual is accurate and complete. However, TEK

More information

ACROMAG INCORPORATED Tel: (248) South Wixom Road Fax: (248) P.O. BOX 437 Wixom, MI U.S.A.

ACROMAG INCORPORATED Tel: (248) South Wixom Road Fax: (248) P.O. BOX 437 Wixom, MI U.S.A. APC-PMC USER S MANUAL ACROMAG INCORPORATED Tel: (248) 295-0310 30765 South Wixom Road Fax: (248) 624-9234 P.O. BOX 437 Wixom, MI 48393-7037 U.S.A. Copyright 2005, Acromag, Inc., Printed in the USA. Data

More information

DYNAMIC ENGINEERING. 150 DuBois, Suite C Santa Cruz, CA (831) Fax (831) Est.

DYNAMIC ENGINEERING. 150 DuBois, Suite C Santa Cruz, CA (831) Fax (831) Est. DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA 95060 (831) 457-8891 Fax (831) 457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 PMC Biserial S311 Software Manual Driver Documentation Developed

More information

PMC494 10BaseT to 10Base2 PMC Media Converter

PMC494 10BaseT to 10Base2 PMC Media Converter GE Fanuc Automation PMC494 10BaseT to 10Base2 PMC Media Converter HARDWARE REFERENCE MANUAL Document Number: Rx-URMH 121 Rev A This page intentionally left blank. 2 of 12 Notice The information in this

More information

TAP Expander Blackhawk Emulator Expansion Pod. Document Part Number: REV B

TAP Expander Blackhawk Emulator Expansion Pod. Document Part Number: REV B CORELIS TAP Expander TAP Expander Blackhawk Emulator Expansion Pod User s Manual Document Part Number: 70397 REV B Copyright 2008 Corelis Inc. 13100 Alondra Blvd. Suite 102 Cerritos, CA 90703-2262 Telephone:

More information

PMC to PCI Express Adapter with JN4 Connector Breakout

PMC to PCI Express Adapter with JN4 Connector Breakout Innovative Integration Real time solutions! Mar 2009, Rev 1.1 PMC to PCI Express Adapter with JN4 Connector Breakout FEATURES Adapt one PMC to a PCI Express slot 4 lane PCI Express Host Interface PCI 64

More information

Pci3Ip, Pci5Ip, Pc104pIp, Pc104p4Ip, cpci2ip, cpci4ip and PcieCar IndustryPack Carrier Device Drivers

Pci3Ip, Pci5Ip, Pc104pIp, Pc104p4Ip, cpci2ip, cpci4ip and PcieCar IndustryPack Carrier Device Drivers DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA 95060 (831) 457-8891 Fax (831) 457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 Pci3Ip, Pci5Ip, Pc104pIp, Pc104p4Ip, cpci2ip, cpci4ip and

More information

Digilab 2E Reference Manual

Digilab 2E Reference Manual Digilent 2E System Board Reference Manual www.digilentinc.com Revision: February 8, 2005 246 East Main Pullman, WA 99163 (509) 334 6306 Voice and Fax Digilab 2E Reference Manual Overview The Digilab 2E

More information

PCIE PCIE GEN2 EXPANSION SYSTEM USER S MANUAL

PCIE PCIE GEN2 EXPANSION SYSTEM USER S MANUAL PCIE2-2711 PCIE GEN2 EXPANSION SYSTEM USER S MANUAL The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies.

More information

DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA (831) Fax (831) Est.

DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA (831) Fax (831) Est. DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA 95060 (831) 457-8891 Fax (831) 457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 IpGeneric WDF Driver Documentation Developed with Windows

More information

Digilab 2 XL Reference Manual

Digilab 2 XL Reference Manual 125 SE High Street Pullman, WA 99163 (509) 334 6306 (Voice and Fax) www.digilentinc.com PRELIMINARY Digilab 2 XL Reference Manual Revision: May 7, 2002 Overview The Digilab 2 XL (D2XL) development board

More information

Revision: 5/7/ E Main Suite D Pullman, WA (509) Voice and Fax. Power jack 5-9VDC. Serial Port. Parallel Port

Revision: 5/7/ E Main Suite D Pullman, WA (509) Voice and Fax. Power jack 5-9VDC. Serial Port. Parallel Port Digilent Digilab 2 Reference Manual www.digilentinc.com Revision: 5/7/02 215 E Main Suite D Pullman, WA 99163 (509) 334 6306 Voice and Fax Overview The Digilab 2 development board (the D2) features the

More information

Installation Instructions

Installation Instructions Installation Instructions This document provides information on: important pre-installation considerations power supply requirements installing the module connecting the wiring using the indicators for

More information

PCI Express XMC to PCI Express Adapter with J16 Connector Breakout DESCRIPTION

PCI Express XMC to PCI Express Adapter with J16 Connector Breakout DESCRIPTION PCI Express XMC to PCI Express Adapter with J16 Connector Breakout FEATURES Adapt one XMC.3 (PCI Express VITA 42.3) module to a PCI Express slot PCI Express x1 lane interface Active signal equalization

More information

spwr_base & spwr_chan

spwr_base & spwr_chan DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 spwr_base & spwr_chan Linux Driver Documentation Manual Revision

More information

Digilab 2 Reference Manual

Digilab 2 Reference Manual 125 SE High Street Pullman, WA 99163 (509) 334 6306 (Voice and Fax) www.digilentinc.com PRELIMINARY Digilab 2 Reference Manual Revision: November 19, 2001 Overview The Digilab 2 (D2) development board

More information

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

DYNAMIC ENGINEERING 150 DuBois St., Suite C Santa Cruz, CA Fax Est.

DYNAMIC ENGINEERING 150 DuBois St., Suite C Santa Cruz, CA Fax Est. DYNAMIC ENGINEERING 150 DuBois St., Suite C Santa Cruz, CA 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 IpTest WDF Driver Documentation For the IP-Test module Developed

More information

Document Part Number: Copyright , Corelis Inc.

Document Part Number: Copyright , Corelis Inc. CORELIS ScanDIMM-200/DDR2 ScanDIMM-200/DDR2 Boundary-Scan Based Digital Tester User s Manual Document Part Number: 71359 Copyright 2007-2009, Corelis Inc. Corelis, Inc. 12607 Hiddencreek Way Cerritos,

More information

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES

LDD M SERIES INSTRUCTION MANUAL LDD M SERIES TM LDD M SERIES LDD M SERIES INSTRUCTION MANUAL P O Box Bozeman, MT 9 Phone (0) -90 Fax (0) -9 email sales@wavelengthelectronics.com www.wavelengthelectronics.com TABLE OF CONTENTS Features... Customer

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

User Manual. IP-Unidig-I-O -24I/O, -24I, -12I12O. 24 Optically Isolated Input/Output with Interrupts IndustryPack

User Manual. IP-Unidig-I-O -24I/O, -24I, -12I12O. 24 Optically Isolated Input/Output with Interrupts IndustryPack User Manual IP-Unidig-I-O -24I/O, -24I, -12I12O 24 Optically Isolated Input/Output with Interrupts IndustryPack Manual Revision: 2 8/2/99 Hardware Revision: A IP-Unidig-I-O -24I/O, -24I, -12I12O 24 Optically

More information

VIP-812A DUAL NETWORKED STATION PORT

VIP-812A DUAL NETWORKED STATION PORT ISSUE 1 VIP-812A DUAL NETWORKED STATION PORT INTRODUCTION The VIP-812A Dual Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN. SPECIFICATIONS

More information

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection

User Manual PCM Port CAN-Bus Mini PCIe Module with Isolation Protection User Manual PCM-2680 2-Port CAN-Bus Mini PCIe Module with Isolation Protection Copyright The documentation and the software included with this product are copyrighted 2013 by Advantech Co., Ltd. All rights

More information

PCIE FIVE SLOT EXPANSION SYSTEM USER S MANUAL

PCIE FIVE SLOT EXPANSION SYSTEM USER S MANUAL PCIE2-2707 FIVE SLOT EXPANSION SYSTEM USER S MANUAL The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies.

More information

MODELS PCIe-DIO-48S PCIe-DIO-48 PCIe-DIO-24S. PCI Express 48 Channel Digital I/O Card with Change of State Detection USER MANUAL

MODELS PCIe-DIO-48S PCIe-DIO-48 PCIe-DIO-24S. PCI Express 48 Channel Digital I/O Card with Change of State Detection USER MANUAL 10623 Roselle Street, San Diego, CA 92121 (858) 550-9559 Fax (858) 550-7322 contactus@accesio.com www.accesio.com MODELS PCIe-DIO-48S PCIe-DIO-48 PCIe-DIO-24S PCI Express 48 Channel Digital I/O Card with

More information

USER S MANUAL. Carrier Card Series APCe8670 PCI Express Bus PMC Carrier

USER S MANUAL. Carrier Card Series APCe8670 PCI Express Bus PMC Carrier Carrier Card Series APCe8670 PCI Express Bus PMC Carrier USER S MANUAL ACROMAG INCORPORATED 30765 South Wixom Road Wixom, MI 48393-2417 U.S.A. Tel: (248) 295-0310 Fax: (248) 624-9234 Copyright 2013, Acromag,

More information

Document Part Number: Edition 1. Copyright 2009, Corelis Inc.

Document Part Number: Edition 1. Copyright 2009, Corelis Inc. CORELIS ScanTAP IsoPod ScanTAP IsoPod TAP Signal Isolation Pod User s Manual Document Part Number: 70406 Edition 1 Copyright 2009, Corelis Inc. Corelis, Inc. 12607 Hiddencreek Way Cerritos, CA 90703 Telephone:

More information

N8VEM S-100 BACKPLANE VERSION 04 MAY 3, 2015 J.B.

N8VEM S-100 BACKPLANE VERSION 04 MAY 3, 2015 J.B. N8VEM S-100 BACKPLANE VERSION 04 MAY 3, 2015 J.B. Background. This board is a copy of Andrew Lynch s Version 03 board (with 8 slots) but with added features. Added features: 9 SLOT Active Termination (copied

More information

OPERATIONS MANUAL PCM-I/O48

OPERATIONS MANUAL PCM-I/O48 OPERATIONS MANUAL PCM-I/O48 NOTE: This manual has been designed and created for use as part of the WinSystems Technical Manuals CD and/or the WinSystems website. If this manual or any portion of the manual

More information

A.G.P. Pro Specification

A.G.P. Pro Specification A.G.P. Pro Specification Revision 1.0 Intel Corporation August 1998 A.G.P. Pro Specification Copyright Intel Corporation 1998 All rights reserved. This specification is provided AS IS with no warranties

More information

DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Ca Fax Est.

DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Ca Fax Est. DYNAMIC ENGINEERING 150 DuBois St. Suite C, Santa Cruz, Ca 95060 831-457-8891 Fax 831-457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 User Manual PMC-PARALLEL-TTL-BA16 Digital Parallel Interface

More information

NPCI-PMC Technical Reference Manual

NPCI-PMC Technical Reference Manual NPCI-PMC PCI Carrier for PMC Modules Technical Reference Manual V1.2 HW Revision 1.1 The NPCI-PMC has been designed by: N.A.T. GmbH Kamillenweg 22 D-53757 Sankt Augustin Phone: ++49/2241/3989-0 Fax: ++49/2241/3989-10

More information

ScanDIMM-240/DDR3/R. Boundary-Scan Based Digital Tester. User's Manual

ScanDIMM-240/DDR3/R. Boundary-Scan Based Digital Tester. User's Manual Boundary-Scan Based Digital Tester User's Manual Document Part Number: 70404 Revision C Copyright Corelis 2010. All rights reserved. Corelis 12607 Hiddencreek Way Cerritos, CA 90703-2146 Telephone: (562)

More information

PcieAltBase & PcieAltChan

PcieAltBase & PcieAltChan DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA 95060 (831) 457-8891 Fax (831) 457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 PcieAltBase & PcieAltChan WDF Driver Documentation For the

More information

PFC Mini TM Power Factor Corrected AC-DC Switchers

PFC Mini TM Power Factor Corrected AC-DC Switchers 21 PFC Mini TM Power Factor Corrected AC-DC Switchers Overview Technical Description The PFC Mini is an extremely low profile switching power supply that combines the advantages of power factor correction,

More information

PCI EXPRESS EXPANSION SYSTEM USER S MANUAL

PCI EXPRESS EXPANSION SYSTEM USER S MANUAL 600-2703 PCI EXPRESS EXPANSION SYSTEM USER S MANUAL The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies.

More information

Table 1 shows all the different variations of output modules available.

Table 1 shows all the different variations of output modules available. This application note will show how to configure the LPM409 / LPM616 modular supplies in a series and parallel connection scheme. For a serial connection scheme see Figure 1. For a parallel connection

More information

Reference Manual DOC. REV. 1.1 AUG 2016 VL-EPH-V6

Reference Manual DOC. REV. 1.1 AUG 2016 VL-EPH-V6 Reference Manual DOC. REV. 1.1 AUG 2016 VL-EPH- Mini DisplayPort to LVDS Adapter WWW.VERSALOGIC.COM 12100 SW Tualatin Road Tualatin, OR 97062-7341 (503) 747-2261 Fax (971) 224-4708 Copyright 2016 VersaLogic

More information

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling.

SmartFan Fusion-4. Speed Control and Alarm for DC Fans CONTROL RESOURCES INCORPORATED. The driving force of motor control & electronics cooling. SmartFan Fusion-4 Speed Control and Alarm for DC Fans The driving force of motor control & electronics cooling. P/N FUS300-F DC Controls SmartFan Fusion-4 is a digital fan speed control and alarm that

More information

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection

User Manual MIOe port CAN-bus PCIE/MIOe Module with Isolation Protection User Manual MIOe-3680 2-port CAN-bus PCIE/MIOe Module with Isolation Protection Copyright The documentation and the software included with this product are copyrighted 2014 by Advantech Co., Ltd. All rights

More information

isppac-powr1208p1 Evaluation Board PAC-POWR1208P1-EV

isppac-powr1208p1 Evaluation Board PAC-POWR1208P1-EV March 2007 Introduction Application Note AN6059 The Lattice Semiconductor isppac -POWR1208P1 In-System-Programmable Analog Circuit allows designers to implement both the analog and digital functions of

More information

Owner s s Manual. SATA A II Aluminum Hot-Swap Systems. Macintosh, Windows, Linux 2 BAY 4 BAY 4 BAY. Rack 8 BAY. Rack

Owner s s Manual. SATA A II Aluminum Hot-Swap Systems. Macintosh, Windows, Linux 2 BAY 4 BAY 4 BAY. Rack 8 BAY. Rack Owner s s Manual SATA A II Aluminum Hot-Swap Systems 2 BAY 4 BAY 4 BAY Rack 8 BAY Rack Macintosh, Windows, Linux SATA (Serial ATA) Hot-Swap Drive System / Case Kit Table of Contents User Guide Page How

More information

B1DIL. AVR32 USB Module. Rev. 1.0 Documentation Rev. 4. Reusch Elektronik Reusch Elektronik, Dipl.-Ing. (FH) Rainer Reusch

B1DIL. AVR32 USB Module. Rev. 1.0 Documentation Rev. 4. Reusch Elektronik Reusch Elektronik, Dipl.-Ing. (FH) Rainer Reusch AVR32 USB Module Rev. 1.0 Documentation Rev. 4 Reusch Elektronik 2011 Reusch Elektronik, Dipl.-Ing. (FH) Rainer Reusch www.reusch-elektronik.de http://products.reworld.eu/b1dil.htm File: _Manual Created:

More information

Document Part Number: Revision B

Document Part Number: Revision B CORELIS TAP Multiplexer TAP Multiplexer TAP Signal Switching Pod User s Manual Document Part Number: 70395 Revision B Copyright 2007 Corelis Inc. 13100 Alondra Blvd. Suite 102 Cerritos, CA 90703-2262 Telephone:

More information

PHLnkBase & PHLnkChan

PHLnkBase & PHLnkChan DYNAMIC ENGINEERING 150 DuBois, Suite C Santa Cruz, CA 95060 (831) 457-8891 Fax (831) 457-4793 http://www.dyneng.com sales@dyneng.com Est. 1988 PHLnkBase & PHLnkChan WDF Driver Documentation For the Six-Channel

More information

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting MIC-3001/8 3U/4U CompactPCI Enclosure for Rackmounting Copyright Notice This document is copyrighted, 1999. All rights are reserved. The original manufacturer reserves the right to make improvements to

More information

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

Brushless DC Motor Controller Specification Assembly 025A0053

Brushless DC Motor Controller Specification Assembly 025A0053 Brushless DC Motor Controller Specification Assembly 025A0053 600A0053 Rev. 2 July 28, 2004 025A0053 Brushless DC Motor Controller Data Sheet Page 1 Revision History Date Rev Description By 5/15/04 1 Initial

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information

VE8014A/VE8014AR QUAD NETWORKED STATION PORT

VE8014A/VE8014AR QUAD NETWORKED STATION PORT ISSUE 2 VE8014A/VE8014AR QUAD NETWORKED STATION PORT INTRODUCTION The VE8014A/VE8014AR Quad Networked Station Port allows most loop start terminal devices to be connected to a managed IP-based LAN/WAN.

More information

XPWR104HR High efficiency PC/104 power supply module User s Manual

XPWR104HR High efficiency PC/104 power supply module User s Manual XPWR104HR High efficiency PC/104 power supply module User s Manual BDM-610020045 Rev. C XPWR104HR Power supply module User s Manual RTD Embedded Technologies, INC. 103 Innovation Blvd. State College, PA

More information

isppac-powr1208 Evaluation Board PAC-POWR1208-EV

isppac-powr1208 Evaluation Board PAC-POWR1208-EV January 2005 Introduction Application Note AN6040 The Lattice Semiconductor isppac -POWR1208 In-System-Programmable Analog Circuit allows designers to implement both the analog and digital functions of

More information

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT

VIP-804 QUAD ENHANCED NETWORK AUDIO PORT ISSUE 6 VIP-804 QUAD ENHANCED NETWORK AUDIO PORT INTRODUCTION The VIP-804 Quad Enhanced Network Audio Port enables voice access to four zones of one-way paging over an IP network, allowing page zones to

More information

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module EASON TECHNOLOGY IO8 & IO24 Break-Out Module p/n 50-00180-01 Revision1.2 Eason Technology, Inc. 7975 Cameron Dr. Bldg 300 Windsor, CA 95492 Phone (707) 837-0120 FAX (707) 837-2742 http://www.eason.com

More information

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

5B Series 16 Channel Backplane 5B01 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM 5B Series 16 Channel Backplane 5B01 FEATURES Mix and Match 5B Series I/O Module Capability Factory Mutual (FM) Approved Approved for Use in Class I, Division2, Groups A, B, C, and D Locations. CE Certified:

More information

1.2 Intel Server Chassis SC5400BASE Summary

1.2 Intel Server Chassis SC5400BASE Summary Introduction Intel Server Chassis SC5400BASE Customization Panels Unpainted Rack Top Cover Slim Line CDROM/USB Floppy Kit Intel Server Chassis SC5400BRP 10-pack Branding / Customization Panels Unpainted

More information