1 KC-PXA270KC-PXA270

2 Handheld ultrasonic flowmeters Reference: AB-FLOW-PO-FL01 Handheld portable ultrasonic flow meter provides abundant capabilities for accurate liquid flow measurement. The utilization of proprietary ultrasound transmission / receiving, transit-time measurement and ultrasonic signal processing technologies allows our flow meter to measure liquid flow rate from outside of a pipe reliably and accurately. The handheld portable clamp-on flow meter is carefully designed so that its user-s are self-explanatory and the instrument is very easy to operate. The unique clamp-on fixture design makes the installation very simple and no special skills or tools required. Due to the non-intrusive nature of the clamp-on technique, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, not pressure dependent, and etc. The handheld portable flow meter is ideal for general flow survey, HVAC hydronic balancing / testing, energy consumption supervision, water conservation management, beverage and food processing, chemical process monitoring, power plant monitoring, and other closed-pipe applications where non-intrusive measurement is required. Benefited from our advanced digital signal processing technology, the handheld ultrasonic flow meter works reliably in both clean and opaque liquid flow. Linearity better than 0.5% Accuracy ±1% Response Time Pipe Size seconds, user-configurable ±0.03 ±52 ft/s (±0.01 ±16 m/s), bi-directional 3/4 240 (DN20mm DN6,000mm)

3 Pipe Material Totalizer Liquid Types Units Liquid Temp Display Security Output port and All metals, most plastics, lined pipe Three 7-digit totals for net, positive and negative flow respectively Virtually all clean liquids and liquids with minor solids(<10,000ppm). Full pipe English (U.S.) or other international metric units 32 F 212 F (0 C 100 C) or 32 F 312 F (0 C 150 C),depending on different transducer type. LCD with backlight,4 16 letters Setup values Modification Lockout. Access code needs unlocking 9-hole RS232C port with simple flowmeter protocol for PC connecting; One isolated OCT for frequency output and pulse output. Transducer Cable Standard 2 15 (2x5m).Longer is available upon request. Transducers Power Supply Data Logger Different type transducers optional. 3 AAA Ni-H built-in batteries. When fully recharged it will last over 10 hours of operation. 100V-240VAC for the charger Built-in data logger can store over 2000 lines of data Housing Material Aluminum alloy protective case. Suitable for normal and harsh environment Case Size Weight Language 7.9 x3.6 x1.3 (200mmx92mmx32mm) 1.2 lbs (538g) with batteries English, French, Spainish, Italian, etc

4 Reference: AB-FLOW-PO-FL02 Clamp on transit-time Technology With Built-in Thermo Printer Portable ultrasonic flow meter is carefully designed for flow check and flow survey easily. The flowmeter can measure different flow test points at one time,and the portable flow meter has a long battery time which can work over 20 hours continuously.with a built-in thermo printer,the portable flow meter can print the data at stop. The clamp-on installing transducers make the portable flowmeter operating easily and no need special training and skills. Clamp-on transducers make no need to cut pipe and no risk of leakage,no pressure drop,no moving parts, no risk of corrosion,etc. Accuracy Better than ±1% Response Time 0.5s Pipe Size Pipe Material Main unit temperature Liquid Types Units Liquid Temp Display Output port and ±0.01 to 32m/s, bi-directional DN15mmm~DN6000mm All metals, most plastics, concrete, lined pipe Virtually all commonly used liquids (full pipe) English (U.S.) or other international metric units 0 to 100 LCD with backlight, 2 10 characters Isolated RS-485,support MODBUS protocol; Built-in printer

5 Transducer Cable Transducers temperature Shielded transducer(sensor) cable Standard length 5m. Max extended 500m Power Supply Ni-H inside battery. When fully recharged, it will last over 20 hours of operation. Or 220Vac(standard),110Vac is optional Case Size Weight Language 210mmx100mmx180mm 2.5kg The current version has English,Italian and Chinese.Chinese version can be deleted for international trade

6 Ultrasonic flowmeters/calorimeters Reference: AB-FLOW-FI-CA01 The low cost ultrasonic flowmeter employs cutting-edge technologies on ultrasonic transit-time measurement, digital signal processing and surface mounting electronics. It provides abundant capabilities for accurate liquid flow measurement from outside of a pipe. The proprietary signal quality tracking and self-adapting techniques allow the system to optimally adapt to different pipe materials automatically. This unit has four local keys which can be used for setting all parameters, including inputing value. This type ultrasonic flowmeter can be equipped with an optional keyboard module. The users can either use the RS-485 or the display / keyboard to program the flowmeter. The transducer installation is also simple and no special skills or tools are required. Due to the non-intrusive nature of the clamp-on technology, there is no pressure drop, no moving parts, no leaks, no risk of contamination, no risk of corrosion, no pressure dependency. This type ultrasonic flow meter is designed for large quantity, low cost applications. Its unique features, particularly very low cost, very high performance and very small size, make it the ideal choice for industrial automation, processing control, water source management, flow meter networking and OEM applications. Accuracy Better than ±1% Response Time 0.5s Pipe Size ft/s( m/s) (DN25mm-DN6000mm)

7 Pipe Material Main unit temperature Liquid Types Units Display Output port and Transducer Cable all common used pipe materials suitable for most pure liquids and liquids with minor particles English (U.S.) or other international metric units LCD backlight 2*20 letters display 4 local keys for all parameters setting and Versatile inputs/outputs,including 3 way 4-20mA input and 2 way OCT output(relay output) and one way 4-20mA output and Isolated RS485 with power surge protection. Support MODBUS.Well suited for reliable networking. Shielded transducer (sensor) cable Standard length 5m. Max extended 500m Power Supply Case Size Language Isolated 8-36V DC power supply mm English, French, Spainish, Italian, etc

8 Reference: AB-FLOW-FI-CA02 The wall mounted ultrasonic flow meter belongs to range of fixed type ultrasonic flow meters, as a good selling product, it has been carefully designed, so it provides abundant capabilities for accurate liquid flow measurement. The wall-mounted unit can support clamp on transducers, insertion hot-tap transducers and inline type transducers. It can be powered by AC and DC power and solar powered. With clamp-on transducers, it is called as clamp on ultrasonic flow meters and can provide many good features:no need to cut pipe,no direct touch to liquid, no pressure drop, no moving parts, no risk of contamination, no risk of corrosion,and etc. With insertion transducers, it will be insertion ultrasonic flow meters and can be used for pipe size>dn80 mm. Insertion flowmeter can support higher accuracy flow measurement. With out patented hot-tap installing tool, insertion transducers can be installed without any flow stop. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time Pipe Size Pipe Material Cable Liquid Types 0.5s (Collecting 128 groups of data each cycle) ±0.03 ±105 ft/s (± m/s), bi-directional (25mm-6000mm) All metals, most plastics, fiber glass, etc. Allow pipe liner Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe)

9 Units Liquid Temp Display Output port and input port and English (U.S.) or metric 0 C 150 C LCD with backlight letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.

10 Reference: AB-FLOW-FI-CA03 Insertion liquid ultrasonic flow meter employs a pair of insertiontype ultrasonic transducers to measure the flow by inserting the transducers into the pipe wall. The transducers do not extrude into the flow, thus, do not generate any disturbance or pressure drop to the flow. Comparing with a clamp-on flowmeter, the biggest advantages of our wetted-type flowmeter are its long-term stability, better signal quality and less installation uncertainty. The last two features can also be translated into higher accuracy. The insertion liquid flow meter is designed for pipe larger than 3 (DN80mm). For smaller pipe, our spoolpiece model, flow cell inlie flow meter, might be a better choice. When pipe size becomes smaller, the cost of a spool-piece inline transducer comes down. The Insertion type ultrasonic flow meter is ideal for flow surveys and closed-pipe applications, such as normal water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Pipe Material ±0.03 ±105 ft/s (± m/s), bi-directional From 80mm All metals, most plastics, fiber glass, etc. Allow pipe liner

11 Cable Liquid Types Units Liquid Temp Display Output port and input port and Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe) English (U.S.) or metric 0 C 150 C LCD with backlight letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.

12 Reference: AB-FLOW-FI-CA04 This type flow meter utilizes a flow cell (or socalled spool-piece) where transducers are already built-in. The big advantage are its high-accuracy and long-term stability. It is calibrated in factory and no extra error will be introduced by installation. Since it is still noninvasive, it does not generate any disturbance or pressure drop to the flow. Abtds-100FB/C/G are all wall-mount type or fixed-installation type, thus are ideal for long-term deployment for flow measurement and closed-pipe applications, such as liquid process control, water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Pipe Material Cable Liquid Types Units Liquid Temp ±0.03 ±105 ft/s (± m/s), bi-directional DN15 DN1000 All metals, most plastics, fiber glass, etc. Allow pipe liner Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe) English (U.S.) or metric 0 C 150 C

13 Display Output port and input port and LCD with backlight letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.

14 Reference: AB-FLOW-FI-CA05 This type flow meter utilizes a flow cell (or socalled spool-piece) where transducers are already built-in. The big advantage are its high-accuracy and long-term stability. It is calibrated in factory and no extra error will be introduced by installation. Since it is still noninvasive, it does not generate any disturbance or pressure drop to the flow. Abtds-100FB/C/G are all wall-mount type or fixed-installation type, thus are ideal for long-term deployment for flow measurement and closed-pipe applications, such as liquid process control, water flow measurement (hot/chill water, city water, sea water), sewage and sludge measurement, and measurements of oil (crude/diesel/fuel), chemicals (alcohol, acids, etc.), beverage, and many other liquids. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Pipe Material Cable Liquid Types Units Liquid Temp ±0.03 ±105 ft/s (± m/s), bi-directional DN15 DN1000 All metals, most plastics, fiber glass, etc. Allow pipe liner Shielded transducer cable. Standard length 15ft (5m). Can be extended to 1640ft (500m). Contact the manufacturer for longer cable requirement. Cable should not be laid in parallel with high-voltage power lines, neither should it be close to strong interference source such as power transformers Virtually all commonly used liquids (full pipe) English (U.S.) or metric 0 C 150 C

15 Display Output port and input port and LCD with backlight letters. Display instantaneous flow rate, accumulated flow rate (positive, negative and net rates), velocity, time, analog inputs, etc. 1) Current output: 4-20mA or 0-20mA. Impedance 600ohm(float blank), Accuracy 0.1%. Module optional. 2) OCT output: frequency signal for instantaneous flow rate (0-9,999Hz selectable), Module optional. 3) Relay pulse output: pulse signal for accumulated flow rate (positive, negative and net rates); double channel OCT output (pules width of one channel is mS,programmable, the fault value is 200ms. 4) Sound alarm:double channel OCT output, 20 type of source signal available 5) Isolated RS485 power surge protection, support MODBUS, MODBUS-ASCII is recommended. M-BUS 1) 3 channel 4-20mA inputs (for signals such as temperature, pressure, liquid level, etc.,also as a digital port.) 2) 2 channel 3-wire PT100 input can measure heater. recording Case Power supply Weight Language Automatically record the following information: 1) The totalizer data of the last 64 days / 64 months / 64 years; 2) The power time and corresponding flow rate of the last 64 times power on and off events; 3) Allow manual or automatic flow loss compensation; 4) The instrument working status of the last 64 days. 5) Programmable ration controller (control by external input signals or MODBUS command.) 6) One bi-directional SATA port can connect a few external equipment, such as 4-20mA, data logger, printer,etc. 7) Working parameters can be solidified to flash memory, automatically call-out the stored parameters. 8) Software updating by 9) Error self-check, and timer for error time Protection Class: IP65 (NEMA 4X) Explosive Proof Class: ExdIIBT4 (for model Abtds-100F2V only) AC: V/ DC24V 2.5kg English, Italian, Chinese now, and Spain, Frech, German, Japanese will be released in the future.

16 Reference: AB-FLOW-FI-CA06 This ultrasonic water meter is our innovation products utilizing advanced transit-time ultrasonic flow measurement technology. Thus, there is no moving part in the sensor, which can ensure the measurement is wear-free and stable over a very long time period. With its maximum 95 C operating temperature and nominal pressure of 1.6MPa, the technical specifications meet the standard for residential meters. Unlike mechanical water meters,the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time,its overall system accuracy doesn t also degrade over time. The designation of this compact meter fits in even the smallest installation conditions and can be mounted separately from the electronics console. The meter also support remote read-out (M-bus or pulse output).when equipped with M-Bus module, as more as 500 water meters can be networked through a twowire bus to a central location for integrated resources management. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size Liquid Types Units ±0.03 ±105 ft/s (± m/s), bi-directional DN15 DN40 Virtually all commonly used liquids (full pipe) English (U.S.) or metric

17 Reference: AB-FLOW-FI-CA07 This ultrasonic water meter is our innovation products utilizing advanced transit-time ultrasonic flow measurement technology. Thus, there is no moving part in the sensor, which can ensure the measurement is wear-free and stable over a very long time period. With its maximum 95 C operating temperature and nominal pressure of 1.6MPa, the technical specifications meet the standard for residential meters. Unlike mechanical water meters,the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time,its overall system accuracy doesn t also degrade over time. The designation of this compact meter fits in even the smallest installation conditions and can be mounted separately from the electronics console. The meter also support remote read-out (M-bus or pulse output).when equipped with M-Bus module, as more as 500 water meters can be networked through a twowire bus to a central location for integrated resources management. Accuracy Normally, ±1% When on-site calibration available, ±0.5%. Response Time 0.5s (Collecting 128 groups of data each cycle) Pipe Size ±0.03 ±105 ft/s (± m/s), bi-directional From DN50 Liquid Types Units Virtually all commonly used liquids (full pipe) English (U.S.) or metric

18 Ultrasonic flowmeters with battery Reference: AB-FLOW-FI-FL01 Applied with Euro standard of EN1413, Ultrasonic water meter is a super low power consumption water meter with high-accuracy industry electronic parts equipped. It has many advantages such as: high accuracy, good reliability, no moving parts, no pressure drop, Low maintenance, etc. It is a excellent substitution of other water meters. With high quality parts and advanced technology, the ultrasonic flow meter/water meter have reached a very excellent performance. Unlike mechanical water meters, the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time,its overall system accuracy doesn t also degrade over time.. Accuracy ±1% or ±2% of reading value Response Time 0.5s Pipe Size Pipe Material Main unit temperature Liquid Types ft/s( m/s) DN15mm-DN1000mm (Inline type transducers) DN80mm-DN800mm (Insertion type transducers) DN15mm-DN800mm (Clamp-on type transducers) Carbon Steel or stainless steel optional Water, sewage and other homogeneous fluids

19 Max pressure Units Output port and 4.0MPa (DN15-DN40mm) 1.6MPa(DN50-DN450mm) 1.0MPa(DN500-DN600mm) 0.6MPa(DN700-DN1000mm) English (U.S.) or other international metric units OCT output; RS485 port support MODBUS, M-BUS;USART(TTL level) output;,gsm meter readings radio transmission; Power Supply Powered by battery capable of sustaining a continuous meter operation for over 5 years just need one lithium battery (3.6V/19AH)

20 Reference: AB-FLOW-FI-FL02 Applied with Euro standard of EN1413, Ultrasonic water meter is a super low power consumption water meter with high-accuracy industry electronic parts equipped. It has many advantages such as: high accuracy, good reliability, no moving parts, no pressure drop, Low maintenance, etc. It is a excellent substitution of other water meters. With high quality parts and advanced technology, the ultrasonic flow meter/water meter have reached a very excellent performance. Unlike mechanical water meters, the ultrasonic water meter has an outstanding long-term stablity. There is no moving parts in its sensor, so its performance doesn t degrade over time, its overall system accuracy doesn t also degrade over time.. Accuracy Class 2 Or Class 3 Response Time 0.5s Pipe Size Main unit temperature ft/s( m/s) Standard insertion transducers DN80-DN800mm;for larger pipe, will need special big insertion transducers. If pipe material is cement or concrete, it will need to use cement insertion transducers Max pressure Units less than 2.5MPa English (U.S.) or other international metric units

21 Display Output port and Transducer Cable Power Supply 96 Segmantal LCD TTL output; RS485 port support MODBUS, M-BUS. Shielded transducer (sensor) cable Standard length 5m. Max extended 500m Over 4 years while under normal working status. s

22 Reference: AB-FLOW-FI-FL03 Ultrasonic water meter is developed from ultrasonic flow meter and powered by battery and only for water flow measurement. Because ultrasonic water meter carryies on many good features from ultrasonic flow meter, such as no moving parts,no pressure drop,completed communication protocol,etc, and ultrasonic flow converter and sensor are IP68 class,ultrasonic water meter will be an ideal choice for water meter as the cost is reduced. Clamp-on ultrasonic water meter refers to the flow transducer is clamp-on type, which is clamped onto pipe surface. Clamp-on installing way doesn t need to cut pipe,so there is no pressure drop,no risk of leakage,no maintainance,etc. But as it is battery powered, clamp-on ultrasonic water meter can t get the same accurate level as that of main powered ultrasonic flow meter. Thus, battery powered clamp-on ultrasonic water meter is only for such request. Usually, we recommend main powered ultrasonic flow meter or battery powered ultrasonic water meter with insertion type sensor or spool piece inline type sensor.though clamp-on ultrasonic water meter is not perfect yet, it is a very promising water flow meter once its accuracy is improved.we will try to our best to improve it.. Accuracy Class 2 Or Class 3 Response Time 0.5s ft/s( m/s) Main unit temperature Units English (U.S.) or other international metric units

23

Ultra Sonic Flowmeter DATASHEET

Ultra Sonic Flowmeter DATASHEET Ultra Sonic Flowmeter DATASHEET JUNHO 2013 ULTRASONIC-FLOWMETER NON-INVASIV / CLAMP-ON-SENSORS Type: IS210-S Technical Information 2013 FLOW THE EXPERT IN LEVEL AND FLOW IS210 Technical Information Intra-Automation

More information

Ultrasonic Heat Flow Meters

Ultrasonic Heat Flow Meters APPLICATIONS Measuring heat flow Sewage and drainage water with small particle quantity Beverage and food processors HVAC hot and cool water Water and waste treatment Power plants, heat energy boiler feed

More information

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow cono Flow The Ultrasonic Flowmeter is designed to measure the fluid velocity of liquid within a closed conduit. The transducers are a non-contacting, clam-on type, which will provide benefits of non-fouling

More information

Clamp-On Transit Time Ultrasonic Flow Meters

Clamp-On Transit Time Ultrasonic Flow Meters APPLICATIONS Water (hot water, cooling water, potable water, sea water etc.) Petroleum products Chemicals, including alcohol, acids, etc HVAC, energy measurement system Beverage, food and pharmaceutical

More information

Series DMHF Heat Meter

Series DMHF Heat Meter Series DMHF Heat Meter The Series DMHF adopt the MultiPulse TM Technology, Digital Signal Processing Technology and Error Correction Technology, which are the state-of-the-art non-invasive flow measurement

More information

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from Series DMTFB Clamp-on Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from outside of a pipe. It utilizes state-of-the-art

More information

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement MEASURE TODAY. ENSURE TOMORROW REGAL Series RH20 Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement Applications The RH20 handheld flowmeter is one of the most powerful yet portable

More information

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement

Applications. Features and Benefits. Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement MEASURE TODAY. ENSURE TOMORROW REGAL Series RH20 Advanced Clamp-on Transit-time Technology for Accurate Flow Measurement Applications The RH20 handheld flowmeter is one of the most powerful yet portable

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100

More information

DIN-Rail Mounted Ultrasonic Flow Meter

DIN-Rail Mounted Ultrasonic Flow Meter DIN-Rail Mounted Ultrasonic Flow Meter The ultrasonic flowmeter is a transit-time fixed type flowmeter and can be as ultrasonic heat meter. Its installing way is standard din-rail mounted and have a very

More information

DMTFP Portable Ultrasonic Flow Meters

DMTFP Portable Ultrasonic Flow Meters DMTFP Portable Ultrasonic Flow Meters Series DMTFP Portable Transit Time Ultrasonic Flow Meter is a state-of-the-art universal transit-time flow meter using MultiPulse TM technology and low-voltage broadband

More information

REGAL Series RH40. Handheld Ultrasonic Flow & BTU Meter. Applications. Features and Benefits

REGAL Series RH40. Handheld Ultrasonic Flow & BTU Meter. Applications. Features and Benefits Applications The RH40 handheld unit is the most compact yet powerful flow / BTU meter on the market. The utilization of our proprietary technologies, such as ultrasonic signal processing, signal quality

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES Water treatment, slurry and process water pumping; Flow balancing; Hydro-electric, cooling, anti-fire stations; ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES The Transit Time Flow Meter of TTFM100

More information

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter A trademark of Spirax Sarco, Inc. Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter Description Engineered for performance excellence, the Sono-Trak Transit Time ultrasonic meter combines non-invasive,

More information

Ultrasonic Flow Meter Brochure

Ultrasonic Flow Meter Brochure Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant

More information

DCT7088 Portable Digital Correlation Transit Time Flowmeter

DCT7088 Portable Digital Correlation Transit Time Flowmeter DCT7088 Portable Digital Correlation Transit Time Flowmeter DCT7088 Portable Digital Correlation Transit Time Flowmeter Applications HVAC Potable water Ultrapure liquids De-ionized water Petroleum products

More information

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES The Transit Time Flow Meter of TTFM100 NEW GENERATION (NG) series measures flow rate by calculating the spreading time of an ultrasonic wave in a liquid, going upstream and downstream into a pipe. This

More information

Regd.off: # Venkateshwara Nagar Colony Meerpet Moulali Hyderabad A.P.India Tel: / /

Regd.off: # Venkateshwara Nagar Colony Meerpet Moulali Hyderabad A.P.India Tel: / / Regd.off: # 5-11-16 Venkateshwara Nagar Colony Meerpet Moulali Hyderabad 500 040 A.P.India Tel: +91-040-27790886 / 39188320 / 9030299892 Email: meters_mas@yahoo.com www.masinstruments.com Economical OEM

More information

ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM. Seil Enterprise Co.

ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM. Seil Enterprise Co. ULTRASONIC FLOW METERS (Series MU) MAXIFLO TM Seil Enterprise Co. Flow Computers Handheld (MU-HA) Portable (MU-PO) Wall Mount (MU-WA) Panel Mount (MU-PA) Transducers Insertion Clamp-on Full Bore Ultra-clean

More information

SITRANS F flowmeters SITRANS F US

SITRANS F flowmeters SITRANS F US SITRANS F flowmeters Siemens AG 2008 Overview Application SITRANS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering Allocation Flow survey verification Lost

More information

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features Applications The DigitalFlow GC868 clamp-on gas flowmeter is a complete ultrasonic flow metering system for measurement of most gases, including: Natural gas Compressed air Fuel gases Erosive gases Corrosive

More information

Technical Specifications

Technical Specifications Technical Specifications EnduroFlow TM Series EF11 Ultrasonic Transit-Time Flowmeter For Permanent Installation FEATURES AND BENEFITS High-accuracy bi-directional flow measurement Velocity, flowrate, volumetric

More information

MH-A UNIVERSAL ULTRASONIC (LIQUID) LEVEL METER

MH-A UNIVERSAL ULTRASONIC (LIQUID) LEVEL METER MH-A UNIVERSAL ULTRASONIC (LIQUID) LEVEL METER Product Introduction MH-A Universal Ultrasonic (liquid) level meter, is our company based on years of experience in the development and manufacture of universal

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

ThermoPro TM Series TP10

ThermoPro TM Series TP10 MEASURE TODAY. ENSURE TOMORROW. ThermoPro TM Series TP10 Applications The TP10 thermal energy measurement meter is an ideal choice for a wide range of applications in HVAC, energy production, energy transfer,

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. Six models for demanding industrial

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview SITRNS F flowmeters Siemens G 2009 Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display computer available today. It can operate in either Wide- Beam Transit-Time or Reflexor

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

OPERATING INSTRUCTIONS

OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS ULTRAFLO UFD3 ULTRASONIC CLAMP-ON FLOW METER FIXED OPTION PORTABLE OPTION (877) 356-5463 (p) 330-331-7331 (f) 330-331-7172 www.flo-corp.com 2017 FLO-CORP REVA 1116 1 Introduction

More information

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features GE Measurement & Control TransPort PT878 Panametrics Portable Liquid Ultrasonic Flowmeter Applications The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system

More information

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features Applications Features The TransPort PT878 portable liquid flowmeter is a complete portable ultrasonic flow metering system for measurement of: Potable water Wastewater Cooling and heating water Ultrapure

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

MMT330 Series Moisture and Temperature Transmitters for Oil

MMT330 Series Moisture and Temperature Transmitters for Oil MMT330 Series Moisture and Temperature Transmitters for Oil Features Continuous online measurement of moisture in oil Ball-valve installation no need to shut down the process or drain the oil Proven Vaisala

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITRNS FUS1010 is the most versatile clamp-on ultrasonic flow display transmitter available today. It can operate in either Wide- Beam Transit time or Reflexor (Doppler) mode, making it suitable

More information

OPTISONIC 6400 Technical Datasheet

OPTISONIC 6400 Technical Datasheet OPTISONIC 6400 Technical Datasheet Portable ultrasonic clamp-on flowmeter User friendly operation through full colour graphic display and full keypad Quick and easy transfer of logged data to your PC through

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITRANS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power

More information

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F US Clamp-on Overview SITRNS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power

More information

Applications. Features And Benefits. Ultrasonic Transit-Time Flowmeter For Permanent Installation

Applications. Features And Benefits. Ultrasonic Transit-Time Flowmeter For Permanent Installation MEASURE TODAY. ENSURE TOMORROW. EnduroFlow Series EF10 Applications Water / Wastewater Hot / Chilled Water / Mixture of Water and Glycol Chemical Liquids and Solvents Petroleum Products Oil / Crude Oil

More information

THE TECHNOLOGY BEHIND THE MEASUREMENT

THE TECHNOLOGY BEHIND THE MEASUREMENT THE TECHNOLOGY BEHIND THE MEASUREMENT The USCX series non-invasive flowmeters work on the transit time ultrasonic principle. This involves sending and receiving ultrasonic pulses from a pair of sensors

More information

PTU300 Combined Pressure, Humidity and Temperature Transmitter

PTU300 Combined Pressure, Humidity and Temperature Transmitter PTU300 Combined Pressure, Humidity and Temperature Transmitter For Demanding Applications Features Barometric pressure, humidity, and temperature measurement in one transmitter RS-232C serial interface

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open

More information

>> Ultrasonic Flow meter User Manual

>> Ultrasonic Flow meter User Manual 1 Contents 1. Products Categories... 2 1.1 Composition of Ultrasonic flow meter... 2 1.2 Types of Converters... 2 1.3 Types of Flow/Temperature transducers... 3 2. Check Components... 3 3. Measuring Diagrams...

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

NF770 Temperature Compensation Liquid Flow Computer

NF770 Temperature Compensation Liquid Flow Computer NF770 Temperature Compensation Liquid Flow Computer Overview Mass Flow measurement at a comparatively low cost can be achieved using the Model NF770 Liquid Flow Computer, an RTD temperature sensor and

More information

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI SITRNS F flowmeters Siemens G 2009 Overview Standard volume (net) or mass flowmeters ( standard volume / mass ) Exceptional repeatability is maintained, independent of changes in temperature, density or

More information

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications Technical specification FLUXUS F501IP Non-invasive ultrasonic flow measurement on buried pipes Permanently installed clamp-on ultrasonic flow measurement system for buried water and wastewater pipes Features

More information

Data sheet deltwavec-f

Data sheet deltwavec-f deltawavec vec-f Data sheet deltwavec-f 1- Channel, 2- Channel, Ex Ultrasonic clamp-on flowmeter for liquids Lindberghstrasse 4, 82178 Puchheim Telefon 089-80906-0, Telefax 089-80906-200 http://www.systec-controls.de

More information

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS. The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered

More information

SOLUTIONS ONICON. Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED

SOLUTIONS ONICON. Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED Innovative HVAC Flow and Energy Measurement Solutions PRECISE, RELIABLE, TRUSTED SOLUTIONS ONICON Flow and Energy Measurement CHILLED WATER HOT WATER DOMESTIC WATER CONDENSER WATER NATURAL GAS STEAM SYSTEMS

More information

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221 Siemens AG 2011 Flow Measurement Overview The transmitter is available in an IP67/NEMA X/6 enclosure and is designed for use in the flowmeters series: SONOKIT (1- or 2-track) FUS380 (2-track) FUE380 (2-track)

More information

HL Series Ultrasonic Level Meter

HL Series Ultrasonic Level Meter HL Series Ultrasonic Level Meter HL Ultrasonic level meter for continuous non-contact level measurement in liquids and solids. It consists of probe and host, both of which are plastic leak-proof structure.

More information

Wireless Applications in Energy Monitoring Systems

Wireless Applications in Energy Monitoring Systems Wireless Applications in Energy Monitoring Systems Andras Kajati Sales Manager andras.kajati@iag.co.at Wolfgang Häusler Director wolfgang.haeusler@iag.co.at Industrie Automation Graz, Ing. W. Häusler GmbH

More information

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter Lightweight and robust hand-held flowmeter with one measurement channel and graphic LCD display For commonly used pipe materials and diameters from 10 mm to over 3.0 m Intuitive menu, Setup Wizard and

More information

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications FH85 Metering Solution for Custody Transfer Applications One Step Ahead in Ultrasonic Flowmetering Main Applications Oil Production & Allocation FSO, FPSO Metering Tanker Off-loading Storage Management

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview Siemens G 2010 Overview pplication SITRNS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering llocation Flow survey verification Lost and unaccounted for (LUF)

More information

Flow Measurement Applications

Flow Measurement Applications Flow Measurement Applications ONICON has been a leading provider of the flow and energy measurement solutions required by the HVAC industry for the past 30 years. As the need for accurate and reliable

More information

Clear Benefits of the KRAL Electronic.

Clear Benefits of the KRAL Electronic. Clear Benefits of the KRAL Electronic. Coordinated to the flowmeters and their applications. Users of conventional universal display units often cannot make use of their device s options. There is often

More information

Aysix 200 Hand-Held Flow Meter

Aysix 200 Hand-Held Flow Meter Aysix 200 Hand-Held Flow Meter Lightweight and robust hand-held flow meter with one measurement channel and graphic LCD display. The Aysix clamp-on ultrasonic flow meters work on the transit-time method.

More information

CALEC energy master The benchmark in energy measurement

CALEC energy master The benchmark in energy measurement CALEC energy master The benchmark in energy measurement District heating and cooling: New tariff structures for optimum plant management Secure investment with long-term stability Type approval to EU/2004/22

More information

FG-3000R Digital Force Gauge Operation Manual

FG-3000R Digital Force Gauge Operation Manual FG-3000R Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

( F L O W I Z F A M I L Y )

( F L O W I Z F A M I L Y ) THE MOST ACCURATE BATTERY POWERED SYSTEM ML 145 ( F L O W I Z F A M I L Y ) E l e c t r o m a g n e t i c c o n v e r t e r p o w e r e d b y b a t t e r i e s, s o l a r p a n e l o r D C p o w e r w

More information

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions

DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions www.vaisala.com DMT340 Series Dewpoint and Temperature Transmitters for Very Dry Conditions The display shows measurement trends, real-time data, and measurement history. Features/Benefits Measures dew

More information

Smart flow meter. Smart phone. Smart idea.

Smart flow meter. Smart phone. Smart idea. Portable Transit Time Ultrasonic Flow Meter for Smartphone Fluid Flow Sensing, Redefined SoundWater Orcas Smart flow meter. Smart phone. Smart idea. Markets Building Services, Chemical, Energy Management,

More information

... f l o w measurement & control...

... f l o w measurement & control... ... f l o w measurement & control... ELECTROMAGNETIC FLOWMETERS OPEN CHANNEL MAGNETIC FLOWMETER PARTLY FILLED PIPE MAGNETIC FLOWMETER VENTURI & PARSHALL FLUMES ULTRASONIC LEVEL MEASUREMENT ULTRASONIC OPEN

More information

DFW Ultrasonic Water Meters

DFW Ultrasonic Water Meters 2012 NEW RELEASE DFW Ultrasonic Water Meters Waterworks and Industrial applications, DN32 600 Available Battery powered -- 6 years life expectancy No moving parts Rugged mechanical design -- IP68 Built-in

More information

TransPort. PT900 Portable Ultrasonic Flow Meter for Liquids. GE Oil & Gas

TransPort. PT900 Portable Ultrasonic Flow Meter for Liquids. GE Oil & Gas GE Oil & Gas TransPort PT900 Portable Ultrasonic Flow Meter for Liquids Introducing the TransPort The TransPort PT900 is the latest generation of portable clamp-on flow meter from GE s Panametrics line

More information

FG-7000L Digital Force Gauge Operation Manual

FG-7000L Digital Force Gauge Operation Manual FG-7000L Digital Force Gauge Operation Manual Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the unit is ON or OFF,

More information

LiquiDens. SensoTech. Process density meter for liquids Product description

LiquiDens. SensoTech. Process density meter for liquids Product description SensoTech LiquiDens Process density meter for liquids Product description SensoTech GmbH, Steinfeldstraße 3, D-39179 Magdeburg-Barleben Tel +49 39203 961300, Fax +49 39203 961309, Internet www.sensotech.com

More information

Family of Water Cut Analyzers

Family of Water Cut Analyzers Phase Dynamics Technology for Precision Measurements Phase Dynamics, Inc. 1251 Columbia Drive Richardson, TX 75081 USA E-Mail sales@phasedynamics.com Tel: 972-680-1550 Fax: 972-680-3262 Family of Water

More information

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications HMT330 Series Humidity and Temperature Transmitters for Industrial Applications The HMT330 transmitter family has the solution for demanding industrial humidity measurements. P.O. Box 26, FI-00421 Helsinki,

More information

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016

XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER. User s Manual FOR LIQUID FLOW. Industrial & Military Instruments. January 2016 Industrial & Military Instruments XONIC 100L ULTRASONIC TRANSIT-TIME FLOWMETER FOR LIQUID FLOW User s Manual January 2016 www.jain.co.kr Tel. 82-2-856-4114 Fax. 82-2-856-9503 Table of Contents Preview

More information

Model FP-100 General Specification

Model FP-100 General Specification Model General Specification Features! Improved metering accuracy and functionality! Single key access to most important parameters! Display of data in userselectable, engineering units! Self diagnostics

More information

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

Technical specification FLUXUS F501. Ultrasonic measurement of water flow Technical specification Ultrasonic measurement of water flow Permanently installed ultrasonic clamp-on system for flow measurement of water Features Non-invasive flow measurement with high measuring accuracy

More information

Advanced Test Equipment Rentals ATEC (2832)

Advanced Test Equipment Rentals ATEC (2832) Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) TRANSPORT PT868 FLOWMETER OPTIONS AND SPECIFICATIONS TRANSPORT FLOWMETER OPTIONS, ACCESSORIES AND The TransPort PT868

More information

C-Flow Coriolis Mass Flow Meter

C-Flow Coriolis Mass Flow Meter Coriolis Mass Flow Meter Application and Features For fluids (e.g. PU components, paints) and gases of high density Suitable for aggressive and contaminated media Measurement of mass flow, density, temperature

More information

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06...

PN DN FIG. 660D-BATT+670D-BATT 661D-BATT+670D-BATT SISTEMI DI MISURA / SYSTEM MEASURE / SYSTEMES DE KAT KAT-06... 1 2 BATTERY-OPERATED WATER METER MAG 8000 MAG 8000 is a comprehensive meter which intelligent information and high performance measurement as well as the easy to install concept take cost of ownership

More information

Flow measurement in open channel. Portable Area-Velocity Mainstream EH7000 P. Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000

Flow measurement in open channel. Portable Area-Velocity Mainstream EH7000 P. Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000 Technical Information TI 051/16/en/09.03 Flow measurement in open channel Portable Area-Velocity Mainstream EH7000 P Ultrasonic Area-Velocity Flow meter MAINSTREAM 7000 Ultrasonic Area-Velocity Flow meter

More information

Dongtai Yanshan Instrument Factory

Dongtai Yanshan Instrument Factory Ultrasonic Meter Catalogue Dongtai Yanshan Instrument Factory YS-2000 Series Ultrasonic flow meter meter is one of a Transit-time flow meters work by measuring the time of flight difference between an

More information

NF760 Batch Controller

NF760 Batch Controller NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total

More information

General Specifications

General Specifications General Specifications US300PM Ultrasonic Flowmeter, Portable type GS 01G05B02-01E GENERAL The model US300PM is a portable ultrasonic flowmeter for measuring liquid flow in a fully filled pipe. With the

More information

SITRANS L Level instruments

SITRANS L Level instruments Overview Technical specifications Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 to 1 m (1 to 0 ft), transducer dependent Measuring points 1 or 2 Input Analog 0

More information

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA

CONVERTER MC406. Electromagnetic flowmeter. The battery powered electronic converter DS400-1-USA CONVERTER MC406 Electromagnetic flowmeter The battery powered electronic converter DS400-1-USA Converter MC406 The MC406 is the new high -efficiency, technologically advanced battery powered electronic

More information

GS828-H. GPRS Data Logger

GS828-H. GPRS Data Logger GPRS Data Logger GS828-H Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors via

More information

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual

SHIMPO INSTRUMENTS. FG-7000T Digital Torque Gauge Operation Manual FG-7000T Digital Torque Gauge Operation Manual SHIMPO INSTRUMENTS Operators should wear protection such as a mask and gloves in case pieces or components break away from the unit under test. Whether the

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT c DWP-98 Series Counting scale User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION

More information

Tofting TF- 100W. Ultrasonic Flowmeter. User Manual Ver. 2.0

Tofting TF- 100W. Ultrasonic Flowmeter. User Manual Ver. 2.0 Tofting TF- 100W Ultrasonic Flowmeter User Manual Ver. 2.0 User Manual Ver. 2.0 Page 2 / 38 Tofting TF- 100W Table of Contents 1 Introduction... 4 1.1 Preface... 4 1.2 Features... 4 1.3 Flow measurement

More information

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195 Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against

More information

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview Flow Measurement Siemens G 2010 Overview pplication SITRNS FUG1010 is ideal for most natural and process gas industry applications, including: Checkmetering llocation Flow survey verification Lost and

More information

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50

2 CLASS AMR READY INVONIC H DATA APPLICATION HEAT METERING. approved ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50 SMART THINKING HEAT INVONIC H ULTRASOUND HEAT AND COOLING METERS DN15, DN20, DN25, DN40, DN50 approved 2 CLASS AMR READY INVONIC H is a modern and precise heat and cooling meter utilising an ultrasound

More information

TPE 1464 Series Pressure Transducer

TPE 1464 Series Pressure Transducer TPE 1464 Series Pressure Transducer Description The KMC TPE 1464 series of pressure transducers incorporate a gauge pressure transmitter featuring low hysteresis, excellent repeatability, and longterm

More information

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter RHE21 Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter Features Wall or Pipe Bracket Mounting Corrosion resistant housing in SS316 available Selectable Units for Mass, Volume, Density

More information

The Micronics U-100 U-100 GPRS. At the heart of your modular clamp-on flow and energy monitoring solution. Local Displays. CalecST Heat Meter

The Micronics U-100 U-100 GPRS. At the heart of your modular clamp-on flow and energy monitoring solution. Local Displays. CalecST Heat Meter The Micronics U-100 At the heart of your modular clamp-on flow and energy monitoring solution. U-100 Local Displays CalecST Heat Meter U100 Software interface Internet Telemetry Monitoring wwweb U100 Ultrasonic

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range

More information

OPERATION MANUAL (Web Site Downloaded only)

OPERATION MANUAL (Web Site Downloaded only) LIQUID LEAK SENSOR OPERATION MANUAL (Web Site Downloaded only) For RS-1000 Series, as following models* Control Unit: RS-1000C RS-1000C-NC RS-1000CA RS-1000CA-NC Detection Unit: RS-1000P RS-1000PP RS-1000F

More information

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel Series TFXB Ultra Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel Part 1. General 1.1 Scope A. This section describes the requirements for an ultrasonic flow measurement transmitter

More information

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions DBC SERIES DBC 150/650 Series Dry Block Temperature Calibrators 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com! s from -45º to 650ºC! Rapid heating, cooling and settling!

More information

imag-series Flanged Magmeter

imag-series Flanged Magmeter s Flow Meters & Controls imag-series o M o vi n g P a r t N FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved (3 only) IP68 rated 9001:2008 ISO