Available for low voltage and high current High slew rate with 100A/μs
|
|
- Joleen Hunter
- 6 years ago
- Views:
Transcription
1 Low voltage input and high slew rate electronic load Available for low voltage and high current High slew rate with 100A/μs Low voltage input and high slew rate electronic load Kenwood TMI Corporation changed the corporate name to Texio Corporation on Dec. 1, TEXIO CORPORATION
2 PXL-151A is an Electronic Load with low voltage input and high slew rate. Outline can be run with minimum operating voltage 0.3V. Slew rate is high speed response such as max. 100A/μs with approx. 4V input and 50A/μs with even approx. 2V input. Equipped with each discharging mode, constant current(cc), constant resistance(cr), constant power(cp), and constant voltage(cv). Those settings and confirmation of setting conditions can be made easily with LCD panel and joystick operation. For external control, GP-IB, USB, and RS-232C interfaces are equipped as standard, and all settings and operations can be performed through computer. It can be used widely in evaluation and testing for micro processor POL and VRM power supplies, other electronic power supply circuits, batteries including fuel cells, electronic components, etc. Features Low voltage operation of 0.3V/ 2 can be run with above min. operation voltage 0.3V Limit by power Input voltage(v) Relations between input voltage / input current ( ) Slew rate setting When keenly changing current such as switching operation, slew rate can be set finely. Slew rate can be set separately for each rising and falling x 160 dot graphic LCD panel Plural number of information such as setting conditions, monitoring values, etc can be displayed on 240 dot x 160 dot graphic LCD panel. Also using joystick and rotary encoder on the front panel, value and mode settings can be made while confirming the LCD panel information. 6 point preset memories Incorporated six preset memories ( PRESET A to F) can memorize different setting values for each discharging mode and range. Preset A, B, and C are located on the front panel for easy readout of each setting value. (Preset D,E, and F are read out with menu display.) External Interface External interfaces, such as GP-IB, USB, and RS-232C are equipped as standard. All setting and monitoring measurement values can be controlled by computer. Various monitoring signals There are trigger signal output which outputs synchronized pulse in switching operation, current monitor which outputs converted voltage level (0V to 1.5V) from input current, and voltage monitor which outputs converted 0V to 3V from input voltage. 1:At internal voltage sensing point 2:At static operation 3:Separate setting is not possible when using external voltage control. Slew rate setting for voltage change in CV discharging mode is not possible. Factory option Low voltage input and high slew rate electronic load PXL-151A Two functions can be added as factory option(installation together with both options is possible. ) 1. Sequence function option Setting for max. 1,024 steps by 10μ s step is possible. 2. Simple logger function option It records loading data. Max. logging time is 72 hours 49 minutes by one cycle/sec (in case of one item ) *Logging time will change by number of logging items.
3 Setting value Available for low voltage and high current High slew rate with 100A/μs Functions Superimposing function Current value corresponded to external input AC voltage can be added (superimposed) to the setting DC current value in constant current (CC) discharging mode. External control Key lock function Control keys on front panel can be locked to avoid mistaken change of setting value or misoperations. Short function Setting value (Dotted line) Setting value can be changed to rating current of the current range at once in CC discharging mode. Setting value can be changed to min. resistance value at once in CR discharging mode. Setting with external voltage(0v to 10V) is possible in all discharging modes *4. Wide frequency characteristics of internal control circuit are 200kHz at 0-10V operation and 1MHz(-3dB) at 2V(p-p).( Actual frequency characteristics of current will change with conditions of power source and wiring.) Also load on/off by external contact is possible. Rated setting value Minimum setting value 0 Soft start function(cc discharging mode only) 10Input voltage(v) Power source output may have distortion due to current rising time of the load effected by output on/off of the power source when loading on. By using soft start function which can set rising time and expecting input voltage for starting current, distortion can be minimized, and much closer test similar to actual load can be made. Current Input voltage Input current Current Current 0 0 Soft start function off Current value corresponding to AC voltage from external input (Solid line) Set operating voltage Input voltage Input current Setting time Soft start function on Switching function Switching operation which changes PRESET A and B alternatively is possible. There are two kinds of methods for setting, which are made by switching frequency(1hz to 50kHz*5) and duty ratio(1% to 99%), and the other by each time for A and B. -related function Elapsed time (from load on to load off) display function, automatic load on timer function to set time for automatic loading start.,and automatic load off timer function to set time for automatic loading off. Remarks: It is not possible to use on timer and off timer at the same time. Failsafe function Intending to safety, variety of protection functions and alarm functions are equipped. Protection function Over current protection(ocp)/over current limit(ocl) When inputted current exceeds set current, it loads off(ocp) or keeps the value(ocl) Over power protection (OPP) / Over power limit (OPL) When inputted power exceeds set power, it loads off (OPP) or keeps the value (OPL). Under voltage protection (UVP) When inputting lower voltage than set value, it loads off. Alarm functions Over voltage alarm (OVA) When inputted approx. 115% of max. input voltage, it loads off. Over current alarm (OCA) When inputted approx. 115% of max. input current, it loads off. Reverse voltage alarm (REVA) *6 When added reverse voltage ( approx.-0.4v) to input terminal, it loads off. Over heat alarm (OHA) When internal heat sink temperature becomes more than 110, it loads off. External alarm (EXTA) PRESET A PRESET B DUTY(%) (A/μs) (A/μs) When inputted alarm signal from outside, it loads off. FREQ(Hz) *4. It can not be set below 0.8V in CV discharging mode. *5. Frequency setting range in CV discharging mode is up to 1kHz. *6. This is alarm function and not to protect the unit.
4 Specifications Input rating Input power Input voltage range Input current range CC,CP CR CV Constant current(cc)discharging mode Ripple Noise(rms) Within 10Hz to 1MHz range Stability(long term drift) Constant resistance (CR)discharging mode (converted current value) Ripple Noise(rms) Within 10Hz to 1MHz range Stability(long term drift)) Constant power (CP) Discharging mode Ripple Noise(rms) Within 10Hz to 1MHz range Stability(long term drift) 0W to 0W to 0.3V to 30V 0V to 30V *It can be operated with 0V, but 0.3V is required to run expecting current with the setting resistance value. 0.8V to 30V 0A to 0A to 0A to 0A to 1mA ±0.2% of setting ±0.1% of fs (23 ±5 ) 100ppm/ ±0.2% of fs (standard value) OPEN,120Ω to 2mΩ 1/120S(approx. 8.33mS) * OPEN,480Ω to 8mΩ 1/480S(approx. 2.08mS) * ±0.5% of setting ± 750mA (23 ±5 ) ±0.5% of setting ± 190mA (23 ±5 ) 1000ppm/ ±0.2% of fs (standard value) 0W to 0.1W 0W to 25mW ±0.5% of setting ±5% of fs (23 ±5 ) 1000ppm/ Constant voltage(cv+cc/cv+cr) discharging mode 30V/ 4V/ 30V/ 4V/ Stability(long term drift) ±3% of fs (standard value) 30V 0.8V to 30V 25mV 4V 0.8V to 4V 5mV 30V 0.8V to 30V 25mV 4V 0.8V to 4V 5mV ±0.2% of setting ± 0.1% of fs (0 to 40 ) ±0.2% of fs (standard value) Short mode CC discharging mode CR discharging mode Switching mode Operating discharging mode Frequency DUTY Slew rate Selectable discharging mode Min.responce time Remote sensing Compensation voltage Soft start Setting time Setting operation voltage External voltage control Control voltage (0 to 40 ) Frequency response Resolution CC CR CP CV 0 to 10V 2V(p-p) Input impedance Control through external interfaces External interface External control Function Current monitor output Monitor voltage Monitor accuracy Output impedance Voltage monitor output Monitor voltage Monitor accuracy DC current measurement Current range Measurement resolution Measurement accuracy Measurement frequency DC voltage measurement Voltage range 4V range Voltage resolution 30V range 4V range Measurement accuracy(23 ±5 ) 30V range Measurement frequency 500S(2mΩ) * 125S(8mΩ) * CC CR CP CV 1Hz to 50kHz ±1.5% of setting 0.1Hz (1Hz to 99.9Hz) 1Hz (100Hz to 999Hz) 10Hz (1kHz to 9.99kHz) (1Hz to 1kHz at CV) 100Hz (10kHz to 50kHz) 1% to 99% *Min.width 10μS, changes according to the frequency. ±1.5% of setting 0.1% step 0.01ms to 500ms ±1.5% of setting 0.01ms (0.01ms to 99.99ms) 0.1ms (100ms to 500ms) CC CR CP 1A/μs to 100A/μs 0.5A/μs 0.25A/μs to 25A/μs 0.25A/μs Typical value(at 4V input) 500ns 2.5V on single side 0.1/1/2/5/10/20/50/100ms ±(30% of setting + 100μs) (0 to 40 ) OFF -0.5V to 30V ±0.1% of setting ±20mV (23 ±5 ) 0.01V 0 to 100% rating for each discharging mode at 0 to 10V input. (Except less than 0.8 V in CV discharging mode) ±(2% of setting + 0.2% of fs) ±(2.5% of setting + 0.7% of fs) ±(2.5% of setting + 1.2% of fs) ±(2% of setting + 0.2% of fs) 200kHz 1MHz(-3dB) Approx. 10kΩ *at internal control circuit. GP-IB USB RS-232C *at internal control circuit LOAD ON/OFF, PRESET A/B, and ALARM input/output 0V to 1.5V output with 0A to input 0V to 1.5V output with 0A to input ±1% of fs 50Ω 0V to 3V output with 0V to 30V input ±1% of fs A A 1mA ±0.2% of rdg ±0.3% of fs(23 ±5 ) 2 times/s V to V autoranging hysteresis is 3.998V 0.1mV (0.0000V to V) 1mV (4.000V to V) ±0.06% of rdg ±0.14% of fs ±0.06% of rdg ±0.09% of fs ±0.003% of rdg ±0.01% of fs 2 times/s
5 Specifications Power measurement Alarm functions (Hardware alarms) Current range W 75.00W Over voltage(ova) Over current (OCA) Loading off with approx 115%( to rating input voltage 30V) Loading off with approx. 115%( to rating input current in each current range) Measurement resolution 10mW Reverse voltage (REVA) Loading off with reverse voltage approx. 0.4V input. Short circuit by FET body diode Measurement frequency 2 times/s Over heat (OHA) Loading off with approx. 110 of internal heat sink UVP Other functions OFF -0.5V to 30V Passing time display Measuring time from loading on to loading off. From 0.1s to 9999 hours 59 minutes 59.9 seconds 10mV ±0.1% of setting ±20mV (23 ±5 ) Automatic load on timer Measuring time to loading on automatically From 1s to 9999 hours 59 minutes 59 seconds OPP, OPL 0W to 315W 0W to 78. Automatic load off timer Operating conditions, dimensions, etc Measuring time to loading on automatically. From 1s to 9999 hours 59 minutes 59 seconds 1W 0.25W Operating temperature 0 to 40 20% to 85%RH(no dew condensation) ±0.5% of setting ±1% of fs (23 ±5 ) Temperature/humidity -20 to 60 OCP, OCL for storage 20% to 85%RH(no dew condensation) 0A to 157.5A 0A to A Power source voltage Power source frequency AC100V to AC240V 50Hz/60Hz 100mA ±0.5% of setting ±1% of fs (23 ±5 ) Power consumption Withstanding insulation voltage Less than 80VA, 35W Preliminary-Frame AC1500V for one minute Preliminary-Secondary AC 2300V for one minute TRIGGER Functions TRIG IN TRIG OUT Sequential operation by inputting pulses (Negative side is common to internal common.) Remarks: Operated with Sequence function(option) only Outputting pulse when shifting in switching operation or sequential operation (Negative side is insulated from internal common.) Insulation resistance Cooling method Dimensions(max. Dimensions) Weight Accessories Preliminary-1, preliminary-secondary DC500V More than 10M ohm Secondary-1 DC250V More than 5M ohm Forced cooling method with fan motor W H D:210(210)mm 124(144)mm 379.8(423.5)mm Approx.9kg Safety instruction x1, Instruction Manual (CD-R)x1, 3 core power cable external control connector on rear panelx1, screws and nuts x 1 set for input terminal connection *Unit (S) means siemens, conductance value (1/resistance value) Apearance and Dimensions
6 Panel explanation MENU, DISPLAY CHANGE Changing main display and menu display. Displaying order, volt meter, current meter, watt meter will change by pressing after pressing SHIFT Key. ESC (LOCAL)/KEY LOCK, SHORT Cancelling setting. Key lock conditions by keeping pressing approx. one sec. Short function on after pressing SHIFT key. LCD Panel Plural number of information, setting condition, monitor value, etc. can be displayed at the same time. SHIFT Shifting each key function. Function displayed in blue color when LED lit. POWER SWITCH Front view SW Switching function on. LOAD Changing load on/off. LED lit when loading. JOYSTICK Moving cursor to up/down and right/ left on main display and menu display. Pressing for fixing selection. When selecting number, changing rough and fine adjustment. Rotary Encoder Use when changing setting value or function for each item. Voltage remote sensing, terminal CURRENT MONITOR Outputting voltage converting from current. Output impedance 50Ω DC Input terminal TRIGGER Output pulse signal at changing binary values in switching operation. PRESET A,B,C Setting value for each discharging mode and each discharging range can be read out just to press the button. Current setting is memorized by pressing after pressing SHIFT KEY. USB connector USB driver is in the attached CD-R. GP-IB connector RS-232C J1 connector Inputting and outputting each signal Input for external voltage control(at "V"setting) Input for superimposing voltage(at "ADD"setting) Output for voltage monitor Input for external trigger Output for voltage Input for PRESET and A/B shifting Input for external load on/off Input for external alarm Output for external load on/off signal Output for alarm Rear view AC INPUT AC power source : AC100V to AC240V Screw for grounding Use when grounding is not available at plug side of AC cable.! Caution To use the product safely and correctly, read well INSTRUCTION MANUAL and CAUTIONS ON SAFETY before using. Do not install the equipment under conditions where contain lot of water, humidity, steam, dust, oil smoke, etc. to avoid fire, electric shock, breakdown, etc. Specifications and design are subject to change without notice. The color of this catalog may differ from the original due to limitation of photo and printing technique.
PROGRAMMABLE DC ELECTRONIC LOAD MODEL 6310A SERIES MODEL 6310A SERIES. Programmable DC Electronic Load. Key Features:
Programmable DC Electronic Load MODEL 6310A SERES Key Features: PROGRAMMABLE DC ELECTRONC LOAD MODEL 6310A SERES The Chroma 6310A series Programmable programmable parameters include: slew rate, DC Electronic
More informationDynamic Fast. Two conditions using same mode Support CC or CR mode. Each condition must use same mode Support CC or CR mode
GW Instek launches new PEL-3000E series programmable single-channel electronic load. In the series, PEL-3031E provides 300W (1V~150V/60A) and PEL-3032E provides 300W(2.5V~500V/15A) current sink capability.
More informationDatasheet 300W Programmable D.C. Electronic Load Stock No. : Model : ENGLISH
Datasheet 300W Programmable D.C. Electronic Load Stock No. : Model : 1225545 PEL-3031E ENGLISH RS PRO launches new PEL-3031E programmable single-channel electronic load. In the series, PEL-3031E provides
More informationREGULATED DC POWER SUPPLIES
Regulated DC Power Supplies Meter display 18V/10A PD18-10A 18V/20A PD18-20A 18V/30A PD18-30A 36V/10A PD36-10A 36V/20A PD36-20A 56V/6A PD56-6A 56V/10A PD56-10A 110V/3A PD110-3A 110V/5A PD110-5A Digital
More informationSeries Watt DC Power Supplies
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Series 2268 850-Watt DC Power Supplies Specifications SPECIFICATION CONDITIONS This document contains
More informationProgrammable D.C. Electronic Load
Programmable D.C. Electronic Load D35 PEL-2004 PEL-2002 FEATURES NEW NEW * Sequence Function to do High Speed Load Simulations * Flexible Configuration with Mainframes and Plug-in Modules * Multiple Independent
More informationGW Instek PEL-3032E DC Load New Product Announcement
GW Instek PEL-3032E DC Load New Product Announcement This document allows GW Instek s partners to quickly grasp the product s main features, FAB and ordering information. GW Instek launches new the PEL-3032E
More informationKONSTANTER SPL Series Programmable Electronic Load
3-349-701-03 2/11.14 4 operating modes: constant current, constant voltage, constant load, constant power High speed sequence and transient measurement, short-circuit proof, battery discharging and other
More informationREGULATED DC POWER SUPPLIES
99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com REGULATED DC POWER SUPPLIES Multiple-output Regulated DC Power Supplies SERIES 4-Output power supply PW18-1.8AQ (18V/1.8A,
More informationSwift Responses with Accurate Measurement
Swift Responses with Accurate Measurement The /1503D are equipped with the excellent transient recovery time, which can, in less than 40us, recover the output voltage to within 100mV of the previous voltage
More informationModel A Mini AC/DC Clamp Meter. User's Guide
Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,
More informationModel INSTRUCTION MANUAL DIGITAL MULTIMETER
Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT
More informationThere are 6 models of the PLR-series. Model number, output voltage, output current and output power are as follows:
GW Instek launches the new generation programmable switching D.C. power supply. The single power output ranges are and 720W. The series comprises 6 models and the voltage ranges are 20V, 36V and 60V. The
More informationProgrammable DC Power Supplies XLN Series
Data Sheet New Family of High Density System Power Supplies The B&K Precision XLN series are programmable, single-output DC power supplies, that provide clean power up to 1560 watts in a compact 1U rackmountable
More informationThere are 6 models of the PLR-series. Model number, output voltage, output current and output power are as follows:
GW Instek launches the new generation programmable switching D.C. power supply. The single power output ranges are and 720W. The series comprises 6 models and the voltage ranges are 20V, 36V and 60V. The
More informationPEL-3031E Programmable D.C. Electronic Load
ISO-9001 CERTIFIED MANUFACTURER GOOD WILL INSTRUMENT CO., LTD. PEL-3031E Programmable D.C. Electronic Load GW Instek launches new PEL-3000E series programmable single-channel electronic load. In the series,
More informationDRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationModel R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.
Model R5010 TRMS Digital Multimeter Instruction Manual reedinstruments www com Table of Contents Safety...3-4 Features... 5 Specifications...5-8 Instrument Description...8-9 Operating Instructions...10-16
More informationCM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL
CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationOPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER
OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CATⅡ)
More informationLow Voltage Characteristics (Typical) Model 63301A/63302A/63303A/ 63306A/63312A/63323A
KEY FEATURES Improve operating speeds of load for auto test system integration Synchronous paralleling control mode, allow Synchronous load control under static and dynamic Loading mode up to 7000W Up
More informationDRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters
The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationModule Load Design The Chroma 6314A 1400W and 6312A 700W
KEY FEATURES Max Power: 200W, 100W 2(Dual), 30W & 250W, 300W, 350W, 600W, 1200W Wide range 0~500 operating voltage Compatibility between 6310 and 6310A Up to 8 channels in one mainframe, for testing multiple
More informationeasy system configuration and will mount in a 19"
KEY FEATURES Max Power: 200W, 100W 2(Dual), 30W & 250W, 300W, 350W, 600W, 1200W Wide range 0~500 operating voltage Compatibility between 6310 and 6310A Up to 8 channels in one mainframe, for testing multiple
More informationProgrammable Switching DC Power Supply
SS-C series (300W~900W,, with RS-232 interface) Introduction SS-C series are high accuracy programmable DC power supply with single output. MPU control, RS-232/RS- 485/USB interface for PC control, the
More informationModel R5010. TRMS Digital Multimeter. Instruction Manual
INSTRUMENTS Model R5010 TRMS Digital Multimeter Instruction Manual Table of Contents Safety...3-4 IEC1010 Overvoltage Installation Category... 3 Warnings... 4 Features... 5 Specifications...5-8 Instrument
More informationDRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.
The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual
More informationPROGRAMMABLE DC ELECTRONIC LOAD
Programmable DC Electronic Load MODEL 6310 Series PROGRAMMABLE DC ELECTRONIC LOAD Chroma Programmable DC Electronic Load 6310 series is suitable for the test and evaluation of multi-output AC/DC power
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More information5VPxA SERIES HIGH POWER DC LOADS
5VP Series DC LOADS Key features: Models from 5kW to 60kW Master/Slave Parallel Operation of up to Eight 5VP Loads for Higher Power Needs up to 480kW Voltage Ranges, 60V, 600V, 1000Vdc or 1250Vdc Current
More informationModel: Pro93 TRUE RMS LEAKAGE CURRENT TESTER
Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER CONTENTS TITLE PAGE I. Safety Information.......1 Environmental Conditions... 1 Explanation of Symbols..... 1 II. Specification..... 2 General Specification...
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More informationDRTS 33. The new generation of advanced three phase relay test set
The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationAutoranging Mini Multimeter
User Manual Autoranging Mini Multimeter Model MN16A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter.
More informationDigital Speed Controller User Manual
Diesel Engine for Generators Digital Speed Controller User Manual (DSC-1000) Ver_1.0 Doosan Infracore 페이지 1 / 36 Contents 1. Product Overview and General Specification 1.1 Product Information 1.2 Product
More informationAfter unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.
PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER midi LOGGER GL820 Quick Start Guide GL820-UM-851 Thank you for choose the midi LOGGER GL820. This
More informationREGULATED DC POWER SUPPLY PAR-A SERIES
INSTRUCTION MANUAL REGULATED DC POWER SUPPLY PAR-A SERIES PAR18-6A PAR36-3A OPTIONAL INTERFACE UNITS FOR PAR-A SERIES IF-41RS IF-41GU IF-41USB B71-0038-01 CONTENTS USING THE PRODUCT SAFELY... Ⅰ-Ⅴ 1. PAR-A
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationHigh-resolution CCD Camera. Model CS3920 PRODUCT SPECIFICATION
High-resolution CCD Camera Model CS3920 PRODUCT SPECIFICATION CONTENTS 1. PRODUCT DESCRIPTION 1 2. FEATURES 1 3. CONFIGURATION 1 4. OPTIONAL ACCESSORIES 1 5. CONNECTION 2 6. SETTING 3 7. SPECIFICATIONS
More informationUser's Guide. Digital Multimeter. Model MN42
User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and
More informationmidi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851
midi LOGGER HV GL2000 Quick Start Guide 604929220 GL2000-UM-851 Thank you for choose the midi LOGGER HV GL2000. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in
More informationPROGRAMMABLE DC ELECTRONIC LOAD MODEL SERIES MODEL SERIES. Programmable DC Electronic Load
Programmable DC Electronic Load MODEL 63200 SERES PROGRAMMABLE DC ELECTRONC LOAD MODEL 63200 SERES Key Features: Power Rating: 2600W,5200W,6500W,10400W, 15600W oltage range: 1-80/ 2.5-500 Current range:
More informationPROGRAMMABLE DC ELECTRONIC LOAD MODEL 6310 SERIES MODEL 6310 SERIES. Programmable DC Electronic Load. Key Features :
Programmable DC Electronic Load MODEL 6310 SERIES Key Features : Max Power: 200W, 100W 2(Dual), 30W & 250W, 300W, 600W, 1200W Wide range 1-500V operating voltage Configuration : Up to 8 channels in one
More informationR5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com
Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery
More informationInstruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314
Instruction Manual 2in1 LAN Tester & Multimeter Model: 57314 1 Contents Introduction... Features... Safety Precautions.. Meter Description... Electrical Specification... Operation.. AutoRanging Multimeter.
More informationDIGITAL MULTIMETERS. Accuracy +5% Resolution 1pF Accessories Test leads, Manual, 9V Battery included Options ST-265, C-90, C W x 6 L x 1.
DIGITAL MULTIMETERS Model M-1700 Model M-2775 Diode and Transistor Test AC/DC Current to 10A Three Way Overload Protection Extra Large 1 display test Data Hold Transistor / Diode Test AC/DC Current to
More informationGL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.
GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and
More informationATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual
ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying
More informationDIGITAL INDICATING CONTROLLER
DB1000 SERIES DIGITAL INDICATING CONTROLLER The DB1000 series is a 96 96mm digital indicating controller with the indicating accuracy of ±0.1% and the control cycle of approximately 0.1 seconds. Various
More informationA variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation
ECONseries BUS: USB Type: Economy, Mini-Instruments ECONseries Economy USB Mini-Instruments Flexible Yet Economical A variety of low-cost ECONseries modules are available to provide flexible yet economical
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationModel R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com
Model R5005 True RMS Industrial Multimeter Instruction Manual reedinstruments com Table of Contents Safety... 4 Features... 5 Specifications...5-6 Instrument Description...7-8 Operating Instructions...9-13
More information99 Washington Street Melrose, MA Phone Toll Free Visit us at INSTRUCTION MANUAL
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com INSTRUCTION MANUAL Test Equipment Depot - 800.517.8431-99 Washington Street Melrose,
More informationDRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System
Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)
More informationMS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD
MS2115B Dual Display Digital Clamp Meter Operation Manual REL MAX B.L ZERO MIN RANGE HOLD B CONTENTS 1. Safety Information...1 1.1 Preparation...1 1.2 Usage...2 1.3 Mark...3 1.4 Maintenance...4 2. Description...4
More informationOptimum sensing capability for LCD manufacturing
SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent
More informationUSER'S MANUAL DCL-650
USER'S MANUAL Clamp on Multimeter - Compact Design True RMS AC/DC DCL-650 CIRCUIT-TEST ELECTRONICS www.circuittest.com Safety International Safety Symbols This symbol, adjacent to another symbol or terminal,
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationProgrammable Relay ZEN V2 Units
Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty
More informationStandards VDE: EN60950; UL1950; C-UL: CSA C22.2 No.234; IEC950; VDE0805
AC/DC Power Supply Multi-output Wide range input for world-wide use (85 264 Vac). This series is a 3ch output model. Features Wide input voltage range: 85-264Vac 110-370Vdc High efficiency & reliability
More informationIT8800 Electronic Load
IT8800 Multi-function electronic load provide programmable parameters for LED current simulation. V IT8811 Model Power Voltage Current Model Power Voltage Current D IT8819H 750W 120V 120A 240A 6KW 60V
More informationSpecifications USB-1408FS
Document Revision 1.1, May, 2006 Copyright 2006, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input Table
More informationmidi LOGGER 900 SERVICE MANUAL GL900-UM-251 GL900-UM
midi LOGGER 900 GL900-UM-251 SERVICE MANUAL GL900-UM-251-01-9370 HISTORY OF REVISIONS No. Date issued Description of revision Page Edition 1 08.07.26 First Printing All 01 GL900-UM-251-9370 i TO ENSURE
More informationUSER MANUAL. True RMS Multimeter. Extech EX430A
USER MANUAL True RMS Multimeter Extech EX430A Introduction Congratulations on your purchase of the Extech EX430A True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,
More informationACTIONI/Q Q498. DC Powered DC Input Field Configurable Isolator with Math Functions
ACTIONI/Q Q498 DC Powered DC Input Field Configurable Isolator with Math Functions Q498-0000 Provides 2 Isolated Analog Inputs, 1 Analog Output & 1 Frequency Output, as well as a Discrete Input & Output
More informationmidi LOGGER GL840 Quick Start Guide GL840-UM-850
midi LOGGER GL840 Quick Start Guide 604849020 GL840-UM-850 Thank you for choose the midi LOGGER GL840. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM
More informationSpecification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0
Specification For 90 Watts Adapter Power Supply Model No: ADB002 Customer ID: 000G Revision: 4.0 Prepared By: Terry Liou Approved By: Jacky Chi PAGE 1 E. C. List 1.0 Original 2.0 Modify 8.3 Weight 3.0
More information3700 SERIES USER MANUAL
SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with
More informationPLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)
TEC (Peltier) Controller PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10) Thank you for purchasing the TEC (Peltier) Controller PLC-24V10AL. Read these operating instructions carefully to ensure effective
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationIDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration
More informationmidi LOGGER 820 GL820-UM-251
midi LOGGER 820 GL820-UM-251 SERVICE MANUAL GL820-UM-251-02-9370 HISTORY OF REVISIONS No. Date issued Description of revision Page Edition 1 10.02.18 First Printing All 01 2 10.04.06 The size of screws
More informationUser Guide. TP3016M Series Switching Mode DC Power Supply
User Guide TP3016M Series Switching Mode DC Power Supply 1 Introduction I. Quick Start 1.1 Front Panel Description 1.2 Pre-Checking 1.3 Quick Start 1.4 Output Checking II. Specifications 2.1 Major Specification
More informationCPS Industrial Power Supply
CPS Industrial Power Supply Power Supply Specification Model Number: FSAK C Series Industrial quality, 1U high, multiple output power supply AC Input: full range, active PFC. DC Output: 6 configurable,
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series
More informationEL 9700 Series. DC Electronic Loads. THE POWER TEST EXPERTS.
EL 9700 Series DC Electronic Loads THE POWER TEST EXPERTS 2 2 EL 9700 Series Features ŸSix Modes of Operation ŸBattery Test and Short Circuit Functions ŸProgrammable Soft-Start ŸArbitrary Waveform Generation
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More informationAmplifiers, Counters, Timers & Controls
Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter
More informationSBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide
SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope Quick Start Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com
More informationLGR-5327 Specifications
s Revision 1.0, April, 2010 Copyright 2010, Measurement Computing Corporation All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in italic text are
More informationDigital Clamp-on Meter Instruction Manual
265 Digital Clamp-on Meter Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 3. Declaration of Conformity...4 B. SAFETY CONSIDERATIONS...5 C. TECHNICAL
More informationH Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION
H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the
More informationMillenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types
Millenium 3 General Characteristics Millenium 3 Compact Range Millenium 3 Expandable Range Millenium 3 Communication Options Millenium 3 Range General environment characteristics for CB, CD, XD, XR and
More informationPROGRAMMABLE DC ELECTRONIC LOAD
Programmable DC Electronic Load MODEL 63200 Series Key Features: Power Rating: 2600W,5200W,6500W,10400W, 15600W oltage range: 1-80/ 2.5-500 Current range: Up to 1000A CC, CR, C, CP load modes Master/Slave
More informationLAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.
Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile
More informationVariable Regulated DC Power Supplies PAD-LA Series
Internet http://www.kikusui.co.jp/ DC Power Supply Variable Regulated DC Power Supplies PAD-LA Series Type III, Type IV, Maximum Output Voltage (16V to 250V) 10 models High Performance and High Reliability
More informationDRTS 66 can test all the following relays
Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs
More informationVariable-switching Regulated DC Power Supplies PAS Series
DC Power Supply POWER FACTOR 0.98 EQUIPPED WITH A POWER-FACTOR CORRECTION CIRCUIT Variable-switching Regulated DC Power Supplies PAS Series Constant voltage/constant current, three types of 350 W, 700
More informationNTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY
NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationOwner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español
Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More information3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A
3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 2 Electronic Energy Recycling Load ERI Series Syntax Interface Overview RS-232 USB LAN GPIB O CAN Analog Analog isolated O Standard O Option /not available
More informationOWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER
OWNER S MANUAL 9908-TE HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the instrument. Failure to understand and comply with
More informationDIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T
DIGITAL MULTIMETER 4 1/2 digits, True RMS Model : DM-9027T Caution Symbol Caution : * Risk of electric shock! Caution : * Do not apply the overload voltage, current to the input terminal! * Remove test
More informationSpecifications PMD-1208FS
Document Revision 1.1, May, 2005 Copyright 2005, Measurement Computing Corporation Typical for 25 C unless otherwise specified. Specifications in italic text are guaranteed by design. Analog input section
More informationKTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters
Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,
More informationTrue RMS Multimeter with IR Thermometer
Owner's Manual True RMS Multimeter with IR Thermometer Model No. 82024 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation
More informationAUTOMOTIVE MICRO-ISO RELAY FEATURES
AUTOMOTIVE MICRO-ISO RELAY RELAYS...... Compliance with RoHS Directive FEATURES Micro-ISO type terminals Small size: mm(l) mm(w) mm(h). inch(l). inch(l). inch(h) Wide line-up PC board and, Resistor and
More informationLGR-5325 Specifications
s Revision 1.0, April, 2010 Copyright 2010, Measurement Computing Corporation s All specifications are subject to change without notice. Typical for 25 C unless otherwise specified. s in italic text are