midi LOGGER 820 GL820-UM-251

Size: px
Start display at page:

Download "midi LOGGER 820 GL820-UM-251"

Transcription

1 midi LOGGER 820 GL820-UM-251 SERVICE MANUAL GL820-UM

2

3 HISTORY OF REVISIONS No. Date issued Description of revision Page Edition First Printing All The size of screws were corrected. 3-5, GL820-UM i

4 TO ENSURE SAFETY This Service Manual has been compiled for the purpose of facilitating repair and maintenance of the GL820 midi LOGGER by Graphtec service personnel and other persons who have undergone equivalent technical training. Maintenance or repair by unauthorized service personnel is to be strictly avoided. Because the GL820 contains numerous internal components with a high electric potential, such work by unauthorized service personnel could cause human injury or serious damage to the GL820 midi LOGGER. GL820-UM ii

5 CONTENTS 1. CONFIGURATION Model Configuration Accessories and Options UPGRADING THE FIRMWARE Note for the firmware upgrading How to Upgrade the GL820 Flash ROM from the USB memory device DISASSEMBLY AND REASSEMBLY Notes on Disassembly and Reassembly Removing the Input Terminal Unit Removing the Side Pads Disassembling the Top Cover and the Bottom Case Assembly Replacing the Main Control Board Replacing the Control Panel Board Replacing the LCD and the Top cover Replacing the AMP Board SETUP PROCEDURES Entering the System Setup Menu AC Line cycle Setting Performing Setup1 (Voltage Input) Performing Setup2 (Room Temperature Compensation) Performing Setup3 (RTD) INSPECTION AND CHECK PROCEDURES Preparations for inspections AC Line Setting Sampling setting Copy the condition settings file How to load the condition settings file to the GL820 from a USB memory device Voltage Measurement Accuracy Temperature Accuracy RTD Accuracy PARTS LISTS Recommended Parts List Parts Lists Outer Casing Bottom Parts Top Parts Bottom Case Terminal Unit Standard Accessories GL820-UM iii

6 7. Block Diagram Main Unit Power Block & Main Control Main Control Block AMP Block Details of the AMP...7-4

7 1. CONFIGURATION 1. CONFIGURATION 1.1 Model Configuration GL820 : 20-channel model with color monitor and internal memory 1.2 Accessories and Options Unit name Model name Description Logic / Alarm cable B-513 DC Drive Cable B-514 Same as GL200/450/500 Battery Pack B-517 Same as GL200/450/500 Humidity Sensor B-530 Same as GL200/450/500 Extended Terminal Base Unit B-537 Option 20 Ch Extended Terminal Unit B-538 Option Rod-shaped K-type thermocouple RIC-410 K-type thermocouple for static surfaces RIC-420 L-shaped K-type thermocouple for static surfaces RIC-430 GL820-UM

8 GL820-UM CONFIGURATION

9 2. UPGRADING THE FIRMWARE The version of your GL820 s firmware can be upgraded by rewriting the flash ROM on the pertinent circuit boards. You can upgrade the firmware by loading the update program to a USB memory device. 2.1 Note for the firmware upgrading Save the measuring condition to the internal memory or the USB memory before the firmware upgrade. Don't turn off the power during upgrading the firmware. 2.2 How to Upgrade the GL820 Flash ROM from the USB memory device Preparations for the upgrade Firmware :MainVerxxxRevxxxxAxx.GL820 Main Program file for GL820 :PatternVerxxxRevxxxxAxx.GL820 Font file for GL820 (1) Connect the AC adapter for the GL820. (2) Turn on the GL820. (3) Copy the two files to a USB memory device from the computer. (Copy the two main program files to root directory of a USB memory. Do not copy them to any folder.) How to upgrade (1) Insert the USB memory device containing the main upgrade program into the GL800's USB port. GL820-UM

10 2. UPGRADING THE FIRMWARE (2) Turn on the GL820 to display the menu below. And then select the upgrade program file by using the [UP Arrow] direction key or the [Down Arrow] direction key. (3) Press [ENTER] key to execute the upgrade. (4) Wait until the display shown below appears or until the beeper sound stops. Note: Don't turn off the GL820 until this process is finished. The following message will appear on the GL820 display in yellow characters when the upgrade is complete. Also the beeper will sound for 5 seconds. Please Turn Off the Power. I have locked up. GL820-UM

11 (5) Turn off the power to the GL820 when the above message is displayed or when the beeper sound stops. (6) Delete the two program files from a USB memory device. This is to avoid upgrading the firmware by mistake. GL820-UM

12

13 3. DISASSEMBLY AND REASSEMBLY 3.1 Notes on Disassembly and Reassembly 3. DISASSEMBLY AND REASSEMBLY During disassembly, disconnect the cables from the specified connectors as necessary. During reassembly, double-check to ensure that the proper cables have been correctly re-connected to the pertinent connectors. Some areas of the control panel unit possess a high electrical potential, so exercise caution to avoid an electrical shock. GL820-UM

14 3. DISASSEMBLY AND REASSEMBLY 3.2 Removing the Input Terminal Unit Disassembly (1) Remove the input terminal unit as shown in the picture below. Pull the terminal unit out towards the direction indicated by the arrow while pressing the two locks at the bottom of the unit. (1) Press the two locks in the direction indicated by arrows. (2) Pull the unit out towards the direction indicated by the arrow. GL820-UM

15 3. DISASSEMBLY AND REASSEMBLY 3.3 Removing the Side Pads Disassembly (1) Peel off the left and right side pads from the main unit. Right side pad Left side pad Main unit Re-assembly (1) Push the left and right side pads against the main unit and then install them on the main unit. GL820-UM

16 3. DISASSEMBLY AND REASSEMBLY 3.4 Disassembling the Top Cover and the Bottom Case Assembly Disassembly (1) Remove the input terminal unit from the main unit (See Section 3.3). (2) Remove the side pads from the main unit (See Section 3.4). (3) Remove the four M2L8 self-tapping screws from the bottom cover. (4) Disconnect the connector between the main control board and the AMP board and then remove the top cover assembly. Top cover assembly Bottom case assembly M2L8 self-tapping screw Re-assembly (1) Re-assemble the top cover assembly and the bottom case assembly in the reverse order in which they were disassembled. GL820-UM

17 3. DISASSEMBLY AND REASSEMBLY 3.5 Replacing the Main Control Board Disassembly (1) Remove the input terminal unit from the main unit (See Section 3.2). (2) Remove the side pads from the main unit (See Section 3.3). (3) Disassemble the top cover assembly and the bottom case assembly (See Section 3.4). (4) Disconnect the LCD flexible cable from the main control board. (5) Remove the two M2L6 self-tapping screws holding the main control board from the top cover assembly. (6) Disconnect the connector between the main control board and the control panel board and then remove the top cover assembly. Fixing tape M2L6 self-tapping screw Core Main control board LED flexible cable Top cover assembly Re-assembly (1) Re-assemble the main control board in the reverse order in which it was disassembled. GL820-UM

18 3. DISASSEMBLY AND REASSEMBLY 3.6 Replacing the Control Panel Board Disassembly (1) Remove the input terminal unit from the main unit (See Section 3.2). (2) Remove the side pads from the main unit (See Section 3.3). (3) Disassemble the top cover assembly and the bottom case assembly (See Section 3.4). (3) Remove the main control board (See Section 3.5). (4) Remove the two M2L6 self-tapping screws holding the LCD bracket, and then detach the LCD bracket. (5) Remove the four M2L6 self-tapping screws holding the control panel board. (6) Remove the control panel board from the top cover assembly. M2L6 self-tapping screw M2L6 self-tapping screw LCD bracket Control panel board Top cover assembly Re-assembly (1) Re-assemble the control panel board in the reverse order in which it was disassembled. GL820-UM

19 3. DISASSEMBLY AND REASSEMBLY 3.7 Replacing the LCD and the Top cover The LCD is supplied together with the top cover assembly. This is avoiding to get the dust between the LCD and the top cover panel. Disassembly (1) Remove the input terminal unit from the main unit (See Section 3.2). (2) Remove the side pads from the main unit (See Section 3.3). (3) Disassemble the top cover assembly and the bottom case assembly (See Section 3.4). (3) Remove the main control board (See Section 3.5). (4) Remove the key pad from the top cover assembly. LCD bracket Control panel board Key pad Top cover assembly with LCD Re-assembly (1) Re-assemble the LCD and the top cover assembly in the reverse order in which it was disassembled. GL820-UM

20 3. DISASSEMBLY AND REASSEMBLY 3.8 Replacing the AMP Board Disassembly (1) Remove the input terminal unit from the main unit (See Section 3.2). (2) Remove the side pads from the main unit (See Section 3.3). (3) Disassemble the top cover assembly and the bottom case assembly (See Section 3.4). (4) Remove the four M2L6 self-tapping screws holding the AMP board from the bottom case assembly. (5) Detach the AMP board from the bottom case assembly. (6) Remove the two M2.6L6 binding head screws holding the terminal unit connector cover. (7) Detach the terminal unit connector cover from the AMP board. M2L6 self-tapping screw AMP board M2.6L6 binding head screw Terminal unit connector cover Bottom case assembly Re-assembly (1) Re-assemble the AMP board in the reverse order in which it was disassembled. (2) Perform the Setup operations for the GL820 when you replace the AMP board. GL820-UM

21 4. SETUP PROCEDURES 4. SETUP PROCEDURES 4.1 Entering the System Setup Menu (1) Press the [MENU] key until the OTHR menu shown below appears. (2) Press the [LEFT DOUBLE ARROW Direction] key 10 times in order to display the Setup menu shown below. (3) Move the cursor to the Mode position using the [Direction] keys. (4) Press the [ENTER] key to display the menu from which you can execute the various Setup operations. Setup mode Setup1 (Basic) Setup2 (Room temp.) Setup3 (RTD temp.) (5) Select the Setup mode using the [Direction] keys, and then press the [ENTER] key. GL820-UM

22 4. SETUP PROCEDURES (6) Move the cursor to the Execute Setup position as shown below. (7) Press the [ENTER] key to start the selected Setup operation. GL820-UM

23 4. SETUP PROCEDURES 4.2 AC Line cycle Setting You must set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line before you perform the Setup operations. How to set the AC line cycle (1) Press the [MENU] key until the "OTHR" menu shown below appears. (2) Move the cursor to the "AC Line cycle" position using the [Direction] keys. (3) Press the [ENTER] key to display the "AC Line cycle" selection menu shown below. (4) Select the appropriate cycle for your AC line. GL820-UM

24 4. SETUP PROCEDURES 4.3 Performing Setup1 (Voltage Input) This procedure is required when any part of the AMP board is replaced. Preparation Have a voltage generator on hand that can output voltage up to 50 VDC (four-digit output). Mutually connect the ground terminals of the voltage generator and the GL820. Set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line. Wiring connection Voltage generator V Connect both ends to GND FG Input cable GND AC adapter Connect to CH1 GL820-UM

25 4. SETUP PROCEDURES Setup procedure (1) As shown in the figure above, connect the output of the voltage generator to the GL820 s CH1 input terminal. (2) Leave the GL820 turned on for at least 30 minutes. And leave the GL820 turned on for at least 10 minutes after wiring. (3) After entering the System Setup mode, open the Setup menu as shown below. Specify the AMP Setup conditions as shown below. Mode :Setup1 (Basic) CH :CH 1 (4) Move the cursor to the Execute Setup position as shown below. GL820-UM

26 4. SETUP PROCEDURES (5) Press the [ENTER] key to start the Setup1 (Basic) operation. Message (6) The GND : [START] message is displayed at the location shown above. (7) Input 0.000mV to the input terminals of channel 1. (8) Press the [START] key and then wait until the "20 mv : [START]" message appears. Specify the voltage generator's output voltage setting to correspond to one of the displayed voltage ranges in the following table, and then input that voltage to the GL820. Message Input Voltage GND mv 20 mv mv 50 mv mv 100 mv mv 200 mv mv 500 mv mv 1 V V 2 V V 5 V V 10 V V 20 V V 50 V V (9) Repeat step (8) by sequentially setting the Measure parameter to 50 mv, 100 mv, 200 mv, 500 mv, 1 V, 2 V, 5 V, 10 V, 20 V and 50 V, and then inputting the corresponding voltage. GL820-UM

27 4. SETUP PROCEDURES (10) When you have finished the Setup operation for 50 V, the "EEPROM : [ENTER]" message appears. Press the [ENTER] key to begin writing the new Setup data to the EEPROM. Message (11) After the setup parameters have been registered to the EEPROM, the display closes and returns to normal mode. (12) Turn off the GL820. This completes the voltage amp setup. GL820-UM

28 4. SETUP PROCEDURES 4.4 Performing Setup2 (Room Temperature Compensation) This procedure is required when any part of the relay board is replaced. Setup the Setup 1 when the amp board was replaced before performing this procedure. Preparation As shown below, use (T: ø0.32 mm, K: ø0.65 mm) temperature compensation leads to connect the input terminals to the 0 C reference temperature device (Zero controller). Set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line. Wiring connection Input 0 V for the output side or short the + and - terminals (K) output side 0 C reference temperature device (Zero Controller) Connect the GND terminals. (K) input side (T) output side (K) compensation lead (T) input side (T) compensation lead AC adapter Connect (T) compensation lead to the CH1, CH6, CH11 and CH16 input terminals. Connect (K) compensation lead to the CH3, CH8, CH13 and CH17 input terminals. CAUTION Connect each compensation copper lead to a single terminal as shown in the above diagram (parallel wiring is not permitted). GL820-UM

29 4. SETUP PROCEDURES Setup procedure (1) As shown in the figure above, connect the inputs of the zero controller to the GL820 s input terminals. (2) Leave the GL820 turned on for at least 30 minutes. And leave the GL820 turned on for at least 10 minutes after wiring. (3) After entering the System Setup mode, open the Setup menu as shown below. Specify the AMP Setup conditions as shown below. Mode :Setup2 (Room temp.) Sensor :Sensor1 Area :Area1 CH :CH 1 (4) Move the cursor to the Execute Setup position as shown below. GL820-UM

30 4. SETUP PROCEDURES (5) Press the [ENTER] key to start the Setup2 (Room temp.) operation. Message (6) The rtemp : [START] message is displayed at the location shown above. (7) Press the [START] key and then wait until the "EEPROM : [ENTER]" message appears. Message (8) Press the [ENTER] key to begin writing the new Setup data to the EEPROM. (9) After the setup parameters have been registered to the EEPROM, the display closes and returns to normal mode. GL820-UM

31 4. SETUP PROCEDURES (10) Re-open the Setup menu as shown below. Specify the AMP Setup conditions as shown below. Mode :Setup2 (Room temp.) Sensor :Sensor1 Area :Area2 CH :CH 1 (11) Repeat steps (4) to (8) for all the areas up to Area 4. (12) Turn off the GL820. This completes the Room temp. setup. Setup flow for the Room temp. Procedure Selected area 1 Area 1 2 Area 2 3 Area 3 4 Area 4 GL820-UM

32 4. SETUP PROCEDURES 4.5 Performing Setup3 (RTD) Preparation Have reference resistors to setup RTD. Reference resistors: 0 Ω (Short), 350 Ω ±0.01%, 2500 Ω ±0.01% As shown below, use reference resistors to connect the CH20. Set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line. Wiring connection Reference resistors: (1) 0 Ω (Short) (2) 350 Ω ±0.01% (3) 2500 Ω ±0.01% (b) (-) (+) Connect to the GND AC adapter Connect to the CH20 input terminals. GL820-UM

33 4. SETUP PROCEDURES Setup procedure (1) As shown in the figure above, connect the reference resistor to the GL820 s input terminals. (2) Leave the GL820 turned on for at least 30 minutes. And leave the GL820 turned on for at least 10 minutes after wiring. (3) After entering the System Setup mode, open the Setup menu as shown below. Specify the AMP Setup conditions as shown below. Mode :Setup3 (RTD temp.) CH :CH 20 (4) Move the cursor to the Execute Setup position as shown below. GL820-UM

34 4. SETUP PROCEDURES (5) Press the [ENTER] key to start the Setup3 (RTD temp.) operation. Message (6) The "0 ohm : [START]" message is displayed at the location shown above. (7) Connect the reference 0 Ω resistor to the input terminals of channel 20. (8) Press the [START] key and then wait until the "350 ohm : [START]" message appears. Replace the reference resistor to correspond to one of the displayed resistors in the following table and then press the [START] key. Message Reference resistor 0 ohm 0 Ω 350 ohm 350 Ω 2500 ohm 2500 Ω (9) Repeat step (8) by sequentially to 350 Ω and 2500 Ω. (10) The "EEPROM : [ENTER]" message appears when the 2500 ohm setup was completed. Message (11) Press the [ENTER] key to begin writing the new Setup data to the EEPROM. (12) After the setup parameters have been registered to the EEPROM, the display closes and returns to normal mode. GL820-UM

35 4. SETUP PROCEDURES (13) Turn off the GL820. This completes the RTD temp. setup. GL820-UM

36

37 5. INSPECTION AND CHECK PROCEDURES 5. INSPECTION AND CHECK PROCEDURES 5.1 Preparations for inspections AC Line Setting (1) Set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line (See Section 4.2) Sampling setting (1) Set the Sampling setting of the GL820 to at least 1 sec or longer Copy the condition settings file Condition settings files :GL820ConditionVolt.CND Condition settings for Voltage accuracy :GL820ConditionTC.CND Condition settings for T and K range accuracy :GL820ConditionPT.CND Condition settings for PT range accuracy (1) Copy the condition settings file to a USB memory device from the computer. GL820-UM

38 5. INSPECTION AND CHECK PROCEDURES How to load the condition settings file to the GL820 from a USB memory device (1) Connect the USB memory device to the GL820. (2) Press the [FILE] key to display the menu below. (3) Move the cursor to the Load position using the [Direction] keys. GL820-UM

39 5. INSPECTION AND CHECK PROCEDURES (4) Press the [ENTER] key to display the menu below. (5) Move the cursor to the File Name position using the [Direction] keys. (6) Press the [ENTER] key to display the menu shown below. (7) Move the cursor to the USB1 position using the [Direction] keys. GL820-UM

40 5. INSPECTION AND CHECK PROCEDURES (8) Press the [Left Arrow Direction] key to display files as shown below. (9) Specify the condition settings file to execute the various inspection operations by using the [DOWN Arrow Direction] key or the [UP Arrow Direction] key. (10) Press the [ENTER] key to display the menu shown below. GL820-UM

41 5. INSPECTION AND CHECK PROCEDURES (11) Move the cursor to the OK position using the [Direction] keys. (12) Press the [ENTER] key to display the menu below. (13) Move the cursor to the OK position using the [Direction] keys. (14) Press the [ENTER] key to load the condition settings file. GL820-UM

42 5. INSPECTION AND CHECK PROCEDURES 5.2 Voltage Measurement Accuracy Supply the reference voltage or frequency determined for each measurement range, and then check the voltage accuracy. Preparation Have a voltage generator on hand that can output voltage up to 50 VDC (using four-digit output). Mutually connect the ground terminals of the voltage generator and the GL820 prior to initiating measurement. Set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line. Set the Sampling setting of the GL820 to at least 1 sec or longer. Wiring connection Same wiring connection as Setup1. (See Setup1 procedure) Setting procedure (1) Load the condition settings file "GL820ConditionVolt.CND" from the USB memory device. Measurement procedure (1) Press the [MENU] key to display the menu shown below. (2) Move the cursor to the Range position of channel 1. (3) Press the [ENTER] key to display the menu shown below, and then select the reference voltage range. GL820-UM

43 5. INSPECTION AND CHECK PROCEDURES (4) Press the [DISPLAY] key until the menu shown below appears. (5) Press the [Left DOUBLE Arrow] key to display the menu shown below. GL820-UM

44 5. INSPECTION AND CHECK PROCEDURES (6) Input the reference voltage for each range according to the table below, and then check that the level of measurement is within the rating. Voltage precision ratings Range Input voltage Factory Rating (±0.08%) Product Rating (±0.1%) 20 mv mv mv to mv mv to mv 50 mv mv mv to mv mv to mv 100 mv mv mv to mv mv to mv 200 mv mv mv to mv mv to mv 500 mv mv mv to mv mv to mv 1 V V V to V V to V 2 V V V to V V to V 5 V V V to V V to V 10 V V V to V V to V 20 V V V to V V to V 50 V V V to V V to V This value will change when the reference voltage is input from the voltage generator. (7) Press the [START/STOP] key when the input voltage stabilizes. (8) Wait until the "Finished" message is displayed, and then display the values as shown below. Message Confirm that this value is within the above ratings after data has been captured. (9) Repeat steps (1) to (8), and then confirm that each value is within the above ratings. GL820-UM

45 5. INSPECTION AND CHECK PROCEDURES 5.3 Temperature Accuracy Preparation Use (T) and (K) temperature compensation leads to connect a 0 C reference temperature device (zero controller) to the GL820 input terminals. Set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line. Set the Sampling setting of the GL820 to at least 1 sec or longer. Wiring connection Same wiring connection as Setup2. (See Setup2 procedure) Setting procedure (1) Load the condition settings file GL820ConditionTC.CND from the USB memory device. Measurement procedure (temperature accuracy) (1) Short the input reference voltage signal for the 0 C reference temperature device (zero controller) according to the table below, then check that the level of measurement is within the rating. Input voltage precision ratings (Type T) Temperature Input voltage Factory Rating Product Rating 0 C mv -0.8 C to +0.8 C -1.0 C to +1.0 C Input voltage precision ratings (Type K) Temperature Input voltage Factory Rating Product Rating 0 C mv -1.0 C to +1.0 C -1.5 C to +1.5 C (2) Press the [DISPLAY] key until the menu shown below appears. GL820-UM

46 5. INSPECTION AND CHECK PROCEDURES (3) Press the [Left DOUBLE Arrow] key to display the menu shown below. (4) Press the [START/STOP] key to measure the temperature. (5) Wait until the "Finished" message is displayed, and then display the values as shown below. Message Confirm that this value is within the above ratings after data has been captured. (6) Check that the level of measurement is within the above rating from the CH1 to the CH10. (7) Press the [CH GROUP] key to display from the CH11 to the CH20. Confirm that this value is within the above ratings after data has been captured. GL820-UM

47 5. INSPECTION AND CHECK PROCEDURES 5.4 RTD Accuracy Preparation Have reference resistors to setup RTD. Reference resistors: 350 Ω ±0.01%, 2500 Ω ±0.01% As shown below, use reference resistors to connect the CH20. Set the AC Line cycle setting of the GL820 to the same cycle as that of your AC line. Wiring connection Same wiring connection as Setup3. (See Setup3 procedure) Setting procedure (1) Load the condition settings file GL820ConditionPT.CND from the USB memory device. Measurement procedure (RTD accuracy) (1) Connect the reference resistor to the input terminals of channel 20. (2) Press the [DISPLAY] key until the menu shown below appears. (3) Press the [Left DOUBLE Arrow] key to display the menu shown below. GL820-UM

48 5. INSPECTION AND CHECK PROCEDURES (4) Press the [CH GROUP] key to display from the CH11 to the CH20. (5) Press the [START/STOP] key to measure. (6) Wait until the "Finished" message is displayed, and then display the values as shown below. Message Confirm that this value is within the below ratings after data has been captured. (7) Check that the level of measurement is within below rating. RTD precision ratings Range Input resistor Reference Temperature Factory Rating Product Rating Pt Ω C C to C C to C Pt Ω C C to C C to C GL820-UM

49 6. PARTS LISTS 6. PARTS LISTS 6.1 Recommended Parts List No. Part No. Part Name Description Q'ty Remarks Main Control Board with SD card, GL AMP Board, GL Control Panel Board 1 Same as GL AC Adapter JP, with AC cable KSAH T1M2 1 Japan AC Adapter UL, with AC cable KSAH T1M2 1 UL AC Adapter CEE, with AC cable KSAH T1M2 1 CEE AC Adapter BS, with AC cable KSAH T1M2 1 BS AC Adapter CCC, with AC cable KSAH T1M2 1 China GL820-UM

50 6. PARTS LISTS 6.2 Parts Lists Outer Casing No. Part No. Part Name Description Q'ty Remarks Rank Top Cover with LCD 1 A Bottom Case 1 C Left Side Pad 1 C Right Side Pad 1 C Outer Casing GL820-UM

51 6. PARTS LISTS Bottom Parts No. Part No. Part Name Description Q'ty Remarks Rank AMP Board 1 A Cover, Connector 1 C Bottom Parts 1 2 GL820-UM

52 6. PARTS LISTS Top Parts No. Part No. Part Name Description Q'ty Remarks Rank Main Control Board, with SD card 1 A Control Panel Board 1 A Top Cover, with LCD 1 A Bracket, LCD 1 C Key Pad 1 C Core, LCD Flexible Cable E04FG C Flexible Cable, LCD FC,RN C Top Parts Fixing tape for core GL820-UM

53 6. PARTS LISTS Replaceable parts for the main control board No. Part No. Part Name Description Q'ty Remarks Rank Switch, AJ76231BF SW1: Power Switch 1 A Connector, HEC JP14: DC Input 1 A USB Type A Connector, XM7A-0442 J7: USB Connector 1 A USB Type B Connector, XM7B-0442 J8: USB Connector 1 A LAN Connector, TM11R-5M2-88-LP J9: LAN Connector 1 A Backup Battery, ML2130-TT BAT1: Backup Battery 1 A GL820-UM

54 6. PARTS LISTS Bottom Case No. Part No. Part Name Description Q'ty Remarks Rank Cover, Battery 1 C Bottom Case 1 C Bottom Case Terminal Unit No. Part No. Part Name Description Q'ty Remarks Rank Terminal Unit 1 A Terminal Base 1 A Terminal Base Plate Including 4 screws 1 A Terminal Base Extension Cable 1 A GL820-UM

55 6. PARTS LISTS Standard Accessories No. Part No. Part Name Description Q'ty Remarks Rank 1 GL820-CDM01M CD Manual, Software 1 B GL820-UM-851 Quick Start Manual 1 English B GL820-UM-801 Quick Start Manual 1 Japanese B AC Adapter JP, with AC cable KSAH T1M2 1 Japan A AC Adapter UL, with AC cable KSAH T1M2 1 UL A AC Adapter CEE, with AC cable KSAH T1M2 1 CEE A AC Adapter BS, with AC cable KSAH T1M2 1 BS A AC Adapter CCC, with AC cable KSAH T1M2 1 China A GL820-UM

56

57 7. BLOCK DIAGRAM 7. Block Diagram 7.1 Main Unit Power Block & Main Control Main Unit Power Block & Main Control Secondary circuit Standard AC IN Primary circuit AC Adapter J14 KSAH T1M2 POWER SW SW Main Control Board (RN *) To Battery1 J15 To Battery2 J16 J13 J6 To Humidity Sensor J205 J203 AMP Board (RN *) J201 J301 KEY Board (RN *) NOTE ISOLATION ISOLATION J401 J403 R ELAY Boar d (RN *) J402 Primary circuit Secondary circuit Signal input circuit : Connector to Connector J501 TERMINAL Board (RN *) J502 With expanded termial option J14 To Battery1 POWER SW J15 SW Main Control Board (RN *) To Battery2 J16 J13 J6 To Humidity Sensor J205 J203 AMP Board (RN *) J202 J301 KEY Board (RN *) TERMINAL Board J501 (RN *) J502 TERMINAL Board J501 (RN *) J502 CA,RN * J401 RELAY Board (RN *) J403 J604 J402 J401 J402 RELAY Board (RN *) J403 J604 TERMINAL BASE J603 Board (RN *) J601 J603 TERMINAL BASE Board J601 (RN *) Up to 10 terminal Base GL820-UM

58 7. BLOCK DIAGRAM 7.2 Main Control Block Main Control Block Secondary circuit FPGA WRITE J2 BAT1 J5 BL FLASH WRITE J3 J4 LCD FFC USB (to FLASH MEMORY) J7 USB (to PC) LAN J8 J9 Main Control Board RN * LCD1 J13 J203 Logic & Alarm & Pulse & Ext-Trig J204 AMP Board RN * GL820-UM

59 7. BLOCK DIAGRAM 7.3 AMP Block AMP Block + 1ch + 2ch + 19ch + 20ch - 1ch - 2ch - 19ch - 20ch b 1ch b 2ch b 19ch b 20ch J504 J504 J505 Signal Input Circuit (RN *) Terminal Board J501 J502 Signal Input Circuit (RN *) Terminal Board J401 J403 J402 J201 Signal Input Circuit Signal Input Circuit Signal Input Circuit Signal Input Circuit Signal Input Circuit Signal Input Circuit Signal Input Circuit Signal Input Circuit Signal Input Circuit Signal Input Circuit To Main Control (RN *) J13 J203 Secondary Circuit Amp Board (RN *) GL820-UM

60 7. BLOCK DIAGRAM 7.3 Details of the AMP Details of AMP Signal Input Circuit Signal Input + - b + - b Temperature Sensor Terminal Board Relay Board (RN *) (RN *) Photo MOS Relay Isolating Decoder Constant Current 1mA Attenuator Selector AMP AMP Selector AMP Board (RN *) AMP AMP AMP AMP AMP A/D DC±5V DC/DC AIC1660CS Isolating Secondary Circuit Photocoupler TLP113 Main Control Board (RN *) DC/DC DCP010505BP-U DC+5V DC+24V AC Adaptor GL820-UM

midi LOGGER 900 SERVICE MANUAL GL900-UM-251 GL900-UM

midi LOGGER 900 SERVICE MANUAL GL900-UM-251 GL900-UM midi LOGGER 900 GL900-UM-251 SERVICE MANUAL GL900-UM-251-01-9370 HISTORY OF REVISIONS No. Date issued Description of revision Page Edition 1 08.07.26 First Printing All 01 GL900-UM-251-9370 i TO ENSURE

More information

midi LOGGER 220 GL220-UM-251

midi LOGGER 220 GL220-UM-251 midi LOGGER 220 GL220-UM-251 SERVICE MANUAL GL220-UM-251-03-9370 HISTORY OF REVISIONS No. Date issued Description of revision Page Edition 1 10.03.29 First Printing All 01 2 10.04.16 The size of screws

More information

midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM

midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM midi LOGGER 200 GL200-UM-251 SERVICE MANUAL GL200-UM-251-03-9370 HISTORY OF REVISIONS No. Date issued Description of revision Page Edition 1 06.02.14 First Printing All 01 2 06.03.29 Information for the

More information

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use.

After unpacking, check the GL820's Exterior to make sure that there are crack or other damage before use. PRESSURE LOAD TORQUE POSITION ROTARY ANGLE TILT ACCELERATION VIBRATION RATE SIGNAL CONDITIONER DATALOGGER midi LOGGER GL820 Quick Start Guide GL820-UM-851 Thank you for choose the midi LOGGER GL820. This

More information

midi LOGGER GL240 Quick Start Guide GL240-UM-852

midi LOGGER GL240 Quick Start Guide GL240-UM-852 midi LOGGER GL240 Quick Start Guide 604249022 GL240-UM-852 Thank you for choosing Graphtec midi LOGGER GL240. The Quick Start Guide is to assist with the basic operations. Please refer to the USER'S MANUAL

More information

midi LOGGER GL840 Quick Start Guide GL840-UM-850

midi LOGGER GL840 Quick Start Guide GL840-UM-850 midi LOGGER GL840 Quick Start Guide 604849020 GL840-UM-850 Thank you for choose the midi LOGGER GL840. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information

midi LOGGER GL240 Quick Start Guide GL240-UM-850

midi LOGGER GL240 Quick Start Guide GL240-UM-850 midi LOGGER GL240 Quick Start Guide 604249020 GL240-UM-850 Thank you for choose the midi LOGGER GL240. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in the CD-ROM

More information

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL820 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL820 midi Logger Built-in 5.7" TFT LCD Color Display Stand-alone or PCconnected operation 20 Analog Channels Standard, Expandable to 200 Input-to-output and channel-to-channel Isolation USB and Ethernet

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC

Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC Handy type 10-channel logger midi LOGGER GL200A Sales Manual GRAPHTEC The midi LOGGER GL200 has evolved 10 channels compact data logger No only for temperature but also for voltage fluctuation measurement

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour. GL200A midi Logger Built-in 3.5" TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor and

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour.

GL220 midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 10 ms to one hour. GL220 midi Logger Built-in 4.3" WQVGA TFT LCD Color Display Stand-alone or PCconnected operation 10 Analog Channels Input-to-output & channel-to-channel Isolation USB PC Interface With its color monitor

More information

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

Druck DPI 620 advanced modular calibrator

Druck DPI 620 advanced modular calibrator GE Sensing & Inspection Technologies A1.1 DPI 620: Channel 1 (CH1) Druck DPI 620 advanced modular calibrator safety and quick reference guide - K0454 Measure (M) / Source (S) / Power (P) a ±30 V (M) b

More information

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851

midi LOGGER HV GL2000 Quick Start Guide GL2000-UM-851 midi LOGGER HV GL2000 Quick Start Guide 604929220 GL2000-UM-851 Thank you for choose the midi LOGGER HV GL2000. This Quick Start Guide describes the basic operations. Please refer to the manual (PDF) in

More information

XL112, XL114 ポータブルデータロガ

XL112, XL114 ポータブルデータロガ User's Manual Introduction Thank you for purchasing our XL100 Portable Data Station/Portable Data Logger. This Quick Setup Manual briefly describes the key operations as well as setting examples of the

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

STYLITIS-POWER OPERATOR S GUIDE

STYLITIS-POWER OPERATOR S GUIDE STYLITIS-POWER OPERATOR S GUIDE Copyright 2008-2016, SYMMETRON Electronic Applications. Second edition in English. April 2016. No part of this publication may be reproduced, stored in retrieval system,

More information

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review... TPR-6 Temperature Protection Relay Instruction Manual Ver. June 1 st 2010 2 Table of Contents 1. TABLE OF CONTENTS 1. Table of Contents... 2 2. Introduction... 3 3. Wiring Diagram... 5 4. Terminals Review...

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

FTC200 & FTA/FTX Quick Installation & Jumper Setting Guide

FTC200 & FTA/FTX Quick Installation & Jumper Setting Guide FTC200 & FTA/FTX Quick Installation & Jumper Setting Guide Accuthermo Technology Corp. Safety Note Please read this entire document before you begin connecting cables and assembling your system Failure

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

EPS 06 in rear housing type A1

EPS 06 in rear housing type A1 Field Installation and / or Replacement of RACO Electronic Position Sensor Board EPS 02 & EPS 06 - Electronic Limit Switches - Analog Output Position Signal - Very Accurate - Easy To Use - Robust - Dependable

More information

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014

Synergy Controller Application Note 1 September 2014, Revision F Tidal Engineering Corporation 2014 Upgrading a VersaTenn III controller with the Synergy Micro 2 Controller Introduction Synergy Controller is Tidal Engineering s line of Environmental l Test Chamber Controllers which and are designed to

More information

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K F3102 / F3107 / F3110 / F3115 / F3210 / F3215 86085K3000020 PN: 86085K3000030 Zavio F3102/F3107/F3110/F3115/F3210/F3215 Quick Installation Guide Please follow the installation steps below to set up F3102

More information

midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division

midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division midi LOGGER GL840 Product Introduction (vol. 1, rev. 2) Overseas Sales and Marketing Division 1. 2 models which are Multi-input and Withstand-voltage in the line-up. Basic Function: All Channel isolated

More information

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS

I-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog

More information

Rotork Fairchild PAX1 Linear Actuator User s Manual

Rotork Fairchild PAX1 Linear Actuator User s Manual Rotork Fairchild PAX1 Linear Actuator User s Manual Product Overview The PAX1 is a flexible low voltage DC powered linear actuator featuring a 5 mm maximum thrust rod stroke moving at speeds up to 0 mm/min

More information

Analog Input Modules

Analog Input Modules Important Product Information Analog Input Modules GFK-2765A Aug 2012 Before using the units To use the units safely and effectively, please read this document and refer to GFK-2745 & network adapter user

More information

Operation Instruction For Temperature Simulator

Operation Instruction For Temperature Simulator Operation Instruction For Temperature Simulator INDEX 1. Safety Information..1 2. Instrument Panel Layout and Function 3 3. Replacing the Battery...4 4. Power-on/off of Simulator 5 5. Output from Simulator...5

More information

Expanding the Basic GL7000 Configuration

Expanding the Basic GL7000 Configuration Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com Expanding the Basic GL7000 Configuration The GL7000 is a modular system that allows you to add analog

More information

GL450 USER S MANUAL MANUAL NO. GL450-UM-151

GL450 USER S MANUAL MANUAL NO. GL450-UM-151 GL450 USER S MANUAL MANUAL NO. GL450-UM-151 Introduction Introduction Thank you for purchasing the GL450 midi LOGGER. Please read this manual thoroughly before attempting to use your new product to ensure

More information

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor.

5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL Fruitland Ave Los Angeles, CA UM Channel Monitor. 5450 NW 33rd Ave, Suite 104 Fort Lauderdale, FL 33309 3211 Fruitland Ave Los Angeles, CA 90058 UM-600 6-Channel Monitor Version 2 Installation and Operation Manual Rev. G P/N145F-12990 PCO 00007462 (c)

More information

Adapter Kit - QSI Electronics to TM Meter Installation Instructions

Adapter Kit - QSI Electronics to TM Meter Installation Instructions Adapter Kit - QSI Electronics to TM Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics

More information

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual

Model (DRS-54V) Ver. 2.0 August. Dongah Rectifier System Operating Manual 2011 Model (DRS-54V) Ver. 2.0 August DRS-54V Dongah Rectifier System AC 240V 1Phase 3WIRE Input -54VDC Output 55A per Shelf 18.5Amps per Module DONGAHELECOMM.LTD _ Proprietary This document contains proprietary

More information

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3. Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and

More information

99 Washington Street Melrose, MA Phone Toll Free Visit us at

99 Washington Street Melrose, MA Phone Toll Free Visit us at 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Table of Contents 1. General Safety Requirements... 1 2. Safety Terms and Symbols...

More information

RS Stock No Instruction Manual RS Input Data Logging Thermometer

RS Stock No Instruction Manual RS Input Data Logging Thermometer RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2

More information

MOSS-DVR-810 Mobile Digital SD Recorder User Manual

MOSS-DVR-810 Mobile Digital SD Recorder User Manual MOSS-DVR-810 Mobile Digital SD Recorder User Manual Before installing and using, be sure to read this Manual for best performance. ATTENTION This product is to be used within the vehicle interior. In order

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series

Analog Input Module. ST-3xxx. User Manual CREVIS Co.,Ltd. Version FnIO S-Series 1 FnIO S-Series Analog Input Module ST-3xxx User Manual Version 1.07 2013 CREVIS Co.,Ltd 2 FnIO S-Series DOCUMENT CHANGE SUMMARY REV PAGE REMARKS DATE EDITOR 1.0 New Document 2011/10/07 JE KANG 1.01 6

More information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 99 Washington Street Melrose, MA 02176 Fax 781-665-0780 TestEquipmentDepot.com IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-609 The Service Information provides the following information: Precautions

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for

More information

Trident and Trident X2 Digital Process and Temperature Panel Meter

Trident and Trident X2 Digital Process and Temperature Panel Meter Sign In New User ISO 9001:2008 Certified Quality System Home Products Online Tools Videos Downloads About Us Store Contact Policies Trident and Trident X2 Digital Process and Temperature Panel Meter Products

More information

GL200 USER S MANUAL MANUAL NO. GL200-UM-151

GL200 USER S MANUAL MANUAL NO. GL200-UM-151 GL200 USER S MANUAL MANUAL NO. GL200-UM-151 Introduction Introduction Thank you for purchasing the GL200 midi LOGGER. Please read this manual thoroughly before attempting to use your new product to ensure

More information

GL900 USER S MANUAL MANUAL NO. GL900-UM-151

GL900 USER S MANUAL MANUAL NO. GL900-UM-151 GL900 USER S MANUAL MANUAL NO. GL900-UM-151 Introduction Introduction Thank you for purchasing the GL900 midi LOGGER. Please read this manual thoroughly before attempting to use your new product to ensure

More information

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter Eltek TU1082 - GenII AQ110A comprehensive portable air quality monitor transmitter AQ110A (serial number 32655 onward) is part of the Eltek GenII family of transmitters and can be used alongside any other

More information

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

INSTALLATION INSTRUCTIONS 921P EntryCheck TM 80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount

More information

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits

More information

Available for low voltage and high current High slew rate with 100A/μs

Available for low voltage and high current High slew rate with 100A/μs Low voltage input and high slew rate electronic load Available for low voltage and high current High slew rate with 100A/μs Low voltage input and high slew rate electronic load Kenwood TMI Corporation

More information

Manual Digital Thermometer PCE-T 390

Manual Digital Thermometer PCE-T 390 PCE Americas Inc. 711 Commerce Way Suite 8 Jupiter FL-33458 USA From outside US: +1 Tel: (561) 320-9162 Fax: (561) 320-9176 info@pce-americas.com PCE Instruments UK Ltd. Units 12/13 Southpoint Business

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If

More information

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection LAN Connection RS485 Connection Relay Connection Digital

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

OPERATION MANUAL MODEL TT-LP

OPERATION MANUAL MODEL TT-LP TURTLE TOUGH OPERATION MANUAL MODEL TT-LP 2-Wire Isolated ph/orp Transmitter turtletough.com.au CONTENT INITIAL INSPECTION 3 INTRODUCTION 3 ASSEMBLY 4 PREPARATION 5 Connection Diagram of Turtle Tough Sensors

More information

Data Platform GL7000

Data Platform GL7000 Data Platform GL7000 Datasheet GL7000 Modular Data Platform Measurement ranges: ±20 mv... ±100 V, thermocouples, Pt100, JPt100, Pt1000, humidity, strain gauge, vibration sensors Measurement channels: up

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

Keystone OM1 - EPI-2 modulating input/output module Installation and Maintenance Instructions

Keystone OM1 - EPI-2 modulating input/output module Installation and Maintenance Instructions Before installation these instructions must be fully read and understood Index 1. Optional module 1: Modulating I/O module... 1 2. Installation... 2 3. OM1 card setting and configuration... 6 4. Monitor

More information

Delta T Dew Heater for CDK

Delta T Dew Heater for CDK Delta T Dew Heater for CDK Delta T Dew Heater for CDK12.5 (125902) Your CDK 12.5 Delta T Dew Heater includes the following: QTY 1 Delta T control box w/ mounting bracket attached 1 2.5Amp AC adapter 2

More information

X725 USB DAC & AMP. User s Manual

X725 USB DAC & AMP. User s Manual X725 USB DAC & AMP User s Manual TVLogic Co., Ltd. owns all intellectual property rights to the technical information detailed in this manual. This manual may only be used by and distributed to authorized

More information

RTD-500 Precision RTD Simulator. Operations Manual.

RTD-500 Precision RTD Simulator. Operations Manual. RTD-500 Precision RTD Simulator Operations Manual. Page 1 of 16 Table of Content. Table of Content....1 1 Scope...3 2 Package Content....3 3 Technical Data....3 4 Preparation for use....4 4.1 Switching

More information

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD

OPERATION MANUAL. SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER. Model : MMA-386SD SD card real time datalogger 3 channels 4-20 ma CURRENT RECORDER Model : MMA-386SD Your purchase of this 3 channels 4-20 ma CURRENT RECORDER marks a step forward for you into the field of precision measurement.

More information

Panasonic. DVD/DVC Camera Seminar VDR-D100/200/300 and PV-GS29/39

Panasonic. DVD/DVC Camera Seminar VDR-D100/200/300 and PV-GS29/39 Panasonic DVD/DVC Camera Seminar VDR-D100/200/300 and PV-GS29/39 Features (VDR-D100~300) DVD Multi DVD-RAM/R/-RW DSC Feature (Disc & SD Card) One Touch Navigation & Joystick Built in Video Light (D105&D200

More information

1. Safety Precautions (Read these precautions before use.)

1. Safety Precautions (Read these precautions before use.) R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications

Universal Expander Module INSTALLATION MANUAL. Overview. Electrical Specifications 12 Universal Expander Module. Installation Notes. Revision 1.2 August. 2003. 1 Reporting Reporting with most Contact ID maps will treat the Mini Expander, Exp32 and Exp16 as the same. (With the exception

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

C100 Portable Multifunction

C100 Portable Multifunction C100 Portable Multifunction Superior Accuracy as compared to Competitors! Wahl C100 Simultaneous Measurement and Generation Rugged IP54 Construction for On Site Use Quick Connect Terminals Measurement

More information

Plasma Panel Replacement Guide DU-42PX12X

Plasma Panel Replacement Guide DU-42PX12X Plasma Panel Replacement Guide DU-42PX12X Panel Replacement: At this point, the panel has been determined to be defective and replacement is necessary. Upon receiving the replacement panel, it must be

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

GL400/350 USER S MANUAL

GL400/350 USER S MANUAL GL400/350 USER S MANUAL MANUAL NO. GL400-UM-151 Introduction Introduction Thank you for purchasing the GL400/350 midi LOGGER. Please read this manual thoroughly before attempting to use your new product

More information

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10) TEC (Peltier) Controller PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10) Thank you for purchasing the TEC (Peltier) Controller PLC-24V10AL. Read these operating instructions carefully to ensure effective

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28

SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS SAFETY INFORMATION... 2 WARNINGS... 28 SECURITEST USER S MANUAL TABLE OF CONTENTS SAFETY PRECAUTIONS...... 1 1. SAFETY INFORMATION...... 2 WARNINGS...... 2 SAFETY INFORMATION..... 3 BATTERY PRECAUTIONS...... 5 2. INTRODUCTION...... 7 FEATURES......

More information

8600 RTU Serial Port Status Cable Assembly for PCM v1.8 25x86 LP Drawings

8600 RTU Serial Port Status Cable Assembly for PCM v1.8 25x86 LP Drawings 8600 RTU Serial Port Status Cable Assembly for PCM-4862 1 v1.8 25x86 LP Drawings 8600 RTU Serial Port Status Cable Assembly for PCA-6135L 2 v1.8 25x86 LP Drawings 2572 RS-232 Status Board Connection 3

More information

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER CONTENTS TITLE PAGE I. Safety Information.......1 Environmental Conditions... 1 Explanation of Symbols..... 1 II. Specification..... 2 General Specification...

More information

User Guide. TP3016M Series Switching Mode DC Power Supply

User Guide. TP3016M Series Switching Mode DC Power Supply User Guide TP3016M Series Switching Mode DC Power Supply 1 Introduction I. Quick Start 1.1 Front Panel Description 1.2 Pre-Checking 1.3 Quick Start 1.4 Output Checking II. Specifications 2.1 Major Specification

More information

SP-100. Service Manual Aug. 02

SP-100. Service Manual Aug. 02 SP-100 Service 2004. Aug. 02 1. Caution for maintenance and Service. Please take care below points when you do Service and Maintenance. (1) Service and Maintenance should be done under safety condition.

More information

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions

Adapter Kit - QSI Electronics to G2 Meter Installation Instructions Adapter Kit - QSI Electronics to G2 Meter Installation Instructions These installation instructions cover the adapter kit installation of the QSI1, QSI2 and QSI3 versions of communications electronics

More information

Scanner 2000 Steam Mass Flow Transmitter

Scanner 2000 Steam Mass Flow Transmitter 3352051/2 IM-P335-24 MI Issue 2 Scanner 2000 Steam Mass Flow Transmitter Installation and Maintenance Instructions 1. Safety information 2. Mechanical installation 3. Configuring software 4. Wiring procedures

More information

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A

Scanner 2000 microefm QuickStart. Installing the Scanner Remote Mount. Direct Mount NUFLO. Part No , Rev. A NUFLO Part No. 30165024, Rev. A Scanner 2000 microefm QuickStart Installing the Scanner 2000 H L H L Flow Direct Mount To install the Scanner 2000 microefm using a direct mount to an orifice or cone meter

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

FIELD REPLACEABLE UNIT DOCUMENTATION. Satellite TM. A20 Series GENERAL INFORMATION. Tools Required for Proper Disassembly and Reassembly:

FIELD REPLACEABLE UNIT DOCUMENTATION. Satellite TM. A20 Series GENERAL INFORMATION. Tools Required for Proper Disassembly and Reassembly: GENERAL INFORMATION Tools Required for Proper Disassembly and Reassembly: 1. Phillips Screwdriver (Size 0&1) 2. 4mm Flat head Screwdriver 3. Case Separator 4. ESD Wrist Strap 5. ESD mats 6. Tweezers Before

More information

Please take serious note of the following warnings:

Please take serious note of the following warnings: TPDIN-SC48-20 MPPT Solar Controller with Passive PoE Switch Wireless Base Stations and Client Devices Surveillance Cameras Remote Control Remote Lighting Off Grid Electronics Congratulations! on your purchase

More information

UNIVERSAL CURRENT CONVERTER

UNIVERSAL CURRENT CONVERTER UNIVERSAL CURRENT / VOLTAGE CONVERTER AC/DC Current / Voltage Analyzer The is the first CURRENT / VOLTAGE CONVERTER & ANALYZER ALL IN ONE - of the market. It allow you to connect all isolated current sensors.

More information

DPM Digital DC Power Meter with Data logging capability. User Manual

DPM Digital DC Power Meter with Data logging capability. User Manual DPM-3232 Digital DC Power Meter with Data logging capability User Manual Introduction As a digital DC power meter, it measures the real time DC Voltage (5-60V), DC Current (0-60A), Watt, and it also displays

More information

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3 INSTALLATION GUIDE InBio Pro Series Access Control Panels Date: June, 2016 Version: 1.3 2 What s in the Box 2 Screws & Anchors 2 Screwdriver 4 Diode CONTENT Contents What s in the Box...2 Optional accessories...4

More information

GL980 USER S MANUAL MANUAL NO.GL980-UM-151

GL980 USER S MANUAL MANUAL NO.GL980-UM-151 GL980 USER S MANUAL MANUAL NO.GL980-UM-151 To Ensure Safe and Correct Use To Ensure Safe and Correct Use To ensure safe and correct use of this device, read this manual thoroughly before use. After having

More information

Setting New Heights in Data Recording

Setting New Heights in Data Recording Isolated/Universal Input, Standalone Multi-Channel Datalogger GL840-M / GL840-WV / Setting New Heights in Data Recording Flexible input system for wide array of applications Wireless LAN capability for

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2

L300 user manual. Programmable DC Electronic Load CONTENTS. Electronic Load Software CAUTION...2 SAFETY NOTES...2 Programmable DC Electronic Load L300 user manual CONTENTS CAUTION......2 SAFETY NOTES......2 Chapter 1 General Introduction...3 1.1 General Introduction......3 1.2 Specification......3 1.3 Features......3

More information