Installation and Operation Manual KHS.U. ISDN "U" Interface Data Module KILOMUX-2100 MODULE

Size: px
Start display at page:

Download "Installation and Operation Manual KHS.U. ISDN "U" Interface Data Module KILOMUX-2100 MODULE"

Transcription

1 Installation and Operation Manual KHS.U ISDN "U" Interface Data Module KILOMUX-2100 MODULE

2

3 KHS.U ISDN "U" Interface Data Module Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications Ltd. ("RAD"). No part of this publication may be reproduced in any form whatsoever without prior written approval by RAD Data Communications. Right, title and interest, all information, copyrights, patents, know-how, trade secrets and other intellectual property or other proprietary rights relating to this manual and to the KHS.U and any software components contained therein are proprietary products of RAD protected under international copyright law and shall be and remain solely with RAD. KHS.U is a registered trademark of RAD. No right, license, or interest to such trademark is granted hereunder, and you agree that no such right, license, or interest shall be asserted by you with respect to such trademark. You shall not copy, reverse compile or reverse assemble all or any portion of the Manual or the KHS.U. You are prohibited from, and shall not, directly or indirectly, develop, market, distribute, license, or sell any product that supports substantially similar functionality as the KHS.U, based on or derived in any way from the KHS.U. Your undertaking in this paragraph shall survive the termination of this Agreement. This Agreement is effective upon your opening of the KHS.U package and shall continue until terminated. RAD may terminate this Agreement upon the breach by you of any term hereof. Upon such termination by RAD, you agree to return to RAD the KHS.U and all copies and portions thereof. For further information contact RAD at the address below or contact your local distributor. International Headquarters RAD Data Communications Ltd. 24 Raoul Wallenberg St. Tel Aviv Israel Tel: Fax: market@rad.com North America Headquarters RAD Data Communications Inc. 900 Corporate Drive Mahwah, NJ USA Tel: (201) , Toll free: Fax: (201) market@radusa.com RAD Data Communications Ltd. Publication No /06

4

5 Quick Start Guide If you are familiar with the KHS.U module, use this guide to prepare it for operation. The KHS.U module contains components sensitive to electrostatic discharge (ESD). Caution To prevent ESD damage, always hold the module by its sides, and do not touch the module components or connectors. 1. Connecting the Cables To connect the KHS.U module interface: Insert the module into the assigned I/O slot and connect the cables as follows: Connect the DC Power cable to the DC PWR-IN socket for external phantom feed voltage. Connect the Channel cable to the corresponding channel. 2. KHS.U Module Channels Configuration Procedure Start the configuration of a specific channel of a KHS.U module by typing the command DEF CH i:j <Enter>, where i is the number of the module slot (1 through 12 for KM-2100 or 1 through 4 for KM-2104) and j is the desired B channel (1 or 2 for KHS.U/S). The channel configuration parameters and their allowed range of values are listed below. KHS.U Module Channels Configuration Procedure 1

6 Quick Start Guide KHS.U Installation and Operation Manual KHS.U Channel Configuration Parameters Parameter Values SPEED D-CONNECT MODE U-TYPE NC YES NO LT NT T0 T1 T2 T3 2 KHS.U Module Channels Configuration Procedure

7 Contents Chapter 1. Introduction 1.1 Overview Versions Applications Features Technical Specifications Chapter 2. Module Installation and Operation 2.1 Scope Module Installation Module Panels Setting the Internal Jumpers Installing a KHS.U Module Connecting the Cables Connecting the Phantom Feed Voltage Normal Indications Configuring KHS.U via the Front Panel Configuring Channel Parameters Chapter 3. Configuration via Supervision Terminal 3.1 Introduction Outline of Configuration Procedure Configuring KHS.U Inclusion of KHS.U in Database Configuring the KHS.U Channel Chapter 4. Alarms and Diagnostics 4.1 Introduction Diagnostic Functions Local Loopback Remote Loopback Recommended Test Sequence Alarm Messages Technical Support Appendix A. Connection Data KHS.U Installation and Operation Manual i

8 Table of Contents ii KHS.U Installation and Operation Manual

9 Chapter 1 Introduction 1.1 Overview The KHS.U module is a data interface module for the Kilomux Modular High-Speed TDM Multiplexer Systems that enable the extension of ISDN lines over non-isdn facilities. The KHS.U module provides a "U" ISDN basic rate access interface, which can be configured to operate as LT (line termination) or NT (network termination). The "U" interface carries two B channels (64 kbps each) and one D channel (16 kbps). The user can individually configure each B channel to support payload data rates of 16, 32, and 64 kbps. Each channel can be independently connected to the Kilomux main link. Therefore, the user needs allocate main link bandwidth only in accordance with the actual payload carried by the module channels. The KHS.U modules can operate over main link data rates, up to 768 kbps; the minimum main link data rate depends on the actual payload carried by the modules installed in the Kilomux enclosure. Versions Applications The KHS.U module is available with one "U" interface The KHS.U module can be used to connect ISDN equipment to an ISDN switch, as shown in Figure 1-1. In this application, the KHS.U module connected directly to the ISDN switch is configured to operate in the NT mode, and the other module is configured to operate in the LT mode. The module transparently transfers the data in the 2B + D channels, and is therefore independent of the ISDN switch in use. ISDN Switch KHS.U (NT) Digital Data Service KHS.U (LT) NT1 Unit TE Unit KM-2100 KM-2100 ISDN Equipment Figure 1-1. Typical KHS.U Application Overview 1-1

10 Chapter 1 Introduction KHS.U Installation and Operation Manual The KHS.U channel interfaces can also serve as dedicated line termination units for the ASM-31 or ASMi-31 short-range modems. The modems operate as network termination units. Figure 1-2 shows a typical application for a KHS.U module in conjunction with ASM-31. This configuration enables the connection of various types of remotely located data equipment such as computer terminals, statistical multiplexers, etc., via the Kilomux-2100/2104 data link. DTE 19.2 kbps ASM-31 (NT) 2-wire up to 5.5 km KHS.U (LT) KHS.U (LT) 2-wire up to 5.5 km ASM-31 (NT) 19.2 kbps DTE KM-2100 KM-2100 Figure 1-2. Typical KHS.U Application in Conjunction with ASM-31 Features Line Interface Characteristics The "U" interface of a KHS.U module supports full duplex transmission of 2B+D channels over one unconditioned 2-wire telephone loop (one twisted pair). The line data rate is 160 kbps, and the line coding is 2B1Q. Using advanced adaptive echo cancellation techniques; the KHS.U interfaces support data transmission up to a maximum line attenuation of 42 db at 40 khz, and a maximum resistance of 1300Ω. This corresponds to a typical range of 5.5 km (3.4 miles) over 26 AWG (0.4 mm) pairs. The nominal line impedance is 135Ω. Operating Modes The KHS.U module has two operating modes: NT mode, which enables the connection of the KHS.U interfaces to ISDN switch lines with LT interface LT mode, which enables the connection of the KHS.U interfaces to network termination (NT) units, e.g., regular NT1 units, ASM-31, or other equipment. Timing The transmit timing used by the KHS.U module is locked to the Kilomux system nodal timing, however the nodal timing mode depends on the selected operating mode: NT mode timing - In the NT mode, the KHS.U interface is usually connected to an ISDN switch, whose timing is generally provided by an accurate and stable source. To use this timing mode, the KHS.U interface must be selected as an external clock source for the Kilomux system. This locks the nodal timing of the Kilomux system to the timing of the ISDN switch. LT mode timing - In the LT mode, the system nodal timing, which can be selected in accordance with other system considerations, determines the timing of the data transmitted to the user network termination equipment (ASM-31, etc.), connected to the KHS.U interface. The receive timing is recovered from the line signal received from the user equipment, which must be an NT unit. 1-2 Overview

11 KHS.U Installation and Operation Manual Chapter 1 Introduction Main Link Bandwidth Requirements The KHS.U module enables controlling the bandwidth occupied on the main link by each individual ISDN channel. Therefore, the user can connect only the required channels of each interface; when the B channels are used at rates lower than their nominal (64 kbps) rate, e.g., 16 kbps or 32 kbps, the module requires main link bandwidth equal to the actual payload data rate. Phantom Feed Function The KHS.U modules can provide power to equipment at the remote end of the line connected to the port, using the phantom feeding method. To produce the phantom feeding power, KHS.U uses an external power source. The external DC source, for example Ringer-2000 unit or KM-Ringer module, is connected directly to the KHS.U module via its external DC PWR-IN connector. KHS.U produces the phantom feed voltage by combining the standard Ringer feed voltage output (-24 VDC or -48 VDC) with the internal +12 VDC supplied by the Kilomux chassis. Since the maximum allowed input voltage for KHS.U is 48 VDC, the maximum resulting phantom feed voltage provided by the module cannot exceed 60 VDC. Refer to Connecting the Phantom Feed Voltage in Chapter 2 for details on the KHS.U phantom feed functions. Configuration, Diagnostics and Management All the module-operating parameters, except for the operating mode (LT or NT), are controlled via the Kilomux supervisory port. The KHS.U module supports self-diagnostics upon power-up, as well as test loopbacks controlled by means of the system management functions, thereby reducing downtime to minimum. Test loopbacks can be individually activated on each module interface, and include local loopback and remote loopback. When downloading is enabled, the remote loopback is activated on the remote Kilomux system unit; with downloading disabled, the loopback is activated on the local Kilomux. In addition to the loopbacks listed above, the panel of the KHS.U module includes two status indicators for each interface: LOS indicator - Lights when the corresponding module interface loses synchronization with the line signal. Also, there was a problem, where KHS.U at side A lost synchronization with the line signal and KHS.U at side B had no indication of it. This problem was solved by KHS.U software version 0.5, and KCL.2 software version The solution is by allocating a bit in the Kilomux frame that transfers indication from side A to side B or vice versa. TST indicator - Lights when a loopback is activated on the corresponding interface. Technical Specifications 1-3

12 Chapter 1 Introduction KHS.U Installation and Operation Manual 1.2 Technical Specifications General Number of Interfaces One Timing Trunk Interface Compliance ANSI T1.601, ETSI DTR/TM 3002 Nominal Line Rate Line Signal Format Transmission Format Line Type Nominal Line Impedance Nominal Transmit Level Maximum Loop Loss Typical Range Line Connector B Channel Payload Rate D Channel Rate 160 kbps (ISDN basic rate access, 2B+D channels) 2B1Q Full duplex 2-wire unconditioned telephone loops (one twisted pair) 135Ω +13 dbm 42 db at 40 khz, max resistance 1300Ω 5.5 km (3.4 miles) over 26 AWG (0.4 mm) line 8-pin RJ-45 per channel 16, 32, or 64 kbps 16 kbps Power Consumption +5V Phantom Feed Bit Mapping Up to 60 VDC NT mode: KHS.U is locked to the clock incoming from the LT LT mode: Transmit timing of the "U" interface is locked to the nodal timing clock; and passed to the remote NT unit (ASMi-31) B Channel (according to data rate): 16 kbps: 2 bits 32 kbps: 4 bits 64 kbps: 8 bits D Channel: 2 bits 1-4 Technical Specifications

13 KHS.U Installation and Operation Manual Chapter 1 Introduction Diagnostics B Channel Local (analog) loopback Remote loopback Indicators LOSS (red) On when a loss of synchronization occurs TST (yellow) On when a loopback test is active Configuration Programmable via the Kilomux front panel, an ASCII terminal connected to the Kilomux supervisory port directly or via Telnet, or a RADview network management station over SNMP Technical Specifications 1-5

14 Chapter 1 Introduction KHS.U Installation and Operation Manual 1-6 Technical Specifications

15 Chapter 2 Module Installation and Operation 2.1 Scope This chapter provides installation and operation instructions for the KHS.U module. The information presented in this chapter supplements the general installation, configuration and operation instructions contained in the Kilomux System Installation and Operation Manual. Caution The KHS.U module contains components sensitive to electrostatic discharge (ESD). To prevent ESD damage, always hold the module by its sides, and do not touch the module components or connectors. Module Panels 2.2 Module Installation All connectors and LED indicators are located on the KHS.U panel, as seen in Figure 2-1, and detailed in Table 2-1. The numbers under the heading "Item" correspond to the identification numbers in Figure 2-1. Module Installation 2-1

16 Chapter 2 Module Installation and Operation KHS.U Installation and Operation Manual KHS.U 1 DC PWR-IN 48 VDC MAX BGND CH-1 2 TST LOS 3 4 Figure 2-1. KHS.U Module Panel Item Name Description 1 DC PWR-IN Connector 2 CH 1 TST Indicator 3 CH 1 LOS Indicator Setting the Internal Jumpers Table 2-1. KHS.U Panel Components 3-pin connector for connection of the external phantom feed voltage On when a test is active on the channel 1 interface On when a loss of synchronization occurs on channel 1 4 CH 1 Connector 8-pin RJ-45 connector for connection to the KHS.U channel 2 interface Connector pin assignments are given in Appendix A The KHS.U module contains two jumpers used for the module configuration, as seen in Figure 2-2. Table 2-2 lists the jumper functions. 2-2 Module Installation

17 KHS.U Installation and Operation Manual Chapter 2 Module Installation and Operation PHANTOM OFF ON MODE LT NT Figure 2-2. KHS.U Module, Internal Settings Table 2-2. KHS.U Jumper Settings Jumper Function Values MODE PHANTOM Selects the module operating mode Controls the phantom feed voltage NT KHS.U operates in the Network Termination mode LT KHS.U operates in the Line Termination mode Default: LT ON Phantom feed voltage is enabled OFF Phantom feed voltage is disabled Default: ON Installing a KHS.U Module The KHS.U module includes additional jumpers, which are factory-set and must not be moved by the user. To install the KHS.U module: Insert the module in the assigned I/O slot of the Kilomux enclosure. Refer to the system installation plan. The module starts operating as soon as it is plugged into an operating Kilomux enclosure. Module Installation 2-3

18 Chapter 2 Module Installation and Operation KHS.U Installation and Operation Manual Connecting the Cables To connect the KHS.U module interface: Identify the cables intended for connection to each channel of this module, and plug them into the appropriate module connectors. Connecting the Phantom Feed Voltage The KHS.U modules can provide power to the equipment at the remote end of the line connected to the port using the phantom feeding method. To produce the phantom feed voltage, KHS.U uses an external power source, for example, the Ringer-2000 unit, or the KM-Ringer module. KHS.U produces the phantom feed voltage by combining the standard Ringer feed voltage output (-24 VDC or -48 VDC) with the internal +12 VDC supplied by the Kilomux chassis as explained in Table 2-3. Table 2-3. Phantom Feed Voltage Options Input Voltage Kilomux Internal Voltage Resulting Differential Feed Voltage -24 VDC +12 VDC 36 VDC -48 VDC +12 VDC 60 VDC Caution Do not apply to KHS.U DC voltages exceeding 48V because it can damage the module. To apply the feed voltage to KHS.U: Connect the DC power cable to the DC PWR-IN connector on the KHS.U panel (see Appendix A for the DC PWR-IN connector pinout). Warning The use of the phantom feed option is limited to instances, in which the far-end equipment is located in the same building, or the network is protected against power surges and power line crosses. Safety is not maintained for other modes of operation. 2.3 Normal Indications During normal operation, both KHS.U indicators must be Off. 2-4 Normal Indications

19 KHS.U Installation and Operation Manual Chapter 2 Module Installation and Operation 2.4 Configuring KHS.U via the Front Panel This section provides configuration instructions for the KHS.U module using the Kilomux front panel. The instructions appearing in this section assume you are familiar with the Kilomux front panel. If necessary, refer to Kilomux System Installation and Operation Manual for general front panel operating instructions, and for instructions on the execution of other configuration activities. Before starting the configuration procedure, obtain the list of prescribed channel parameters from the system administrator. Configuring Channel Parameters To configure a specific channel: 1. Display CH PARM on the Kilomux front panel LCD. 2. Scroll the channel identification field until you see the required module and channel numbers. 3. After the required channel is selected, assign values to the channel parameters. The KHS.U B-channels are identified as follows: KHS.U/S: B channel 1 channel 1 B channel 2 channel 2. Table 2-4. KHS.U Channel Parameters Designation Function Values Configuration Guidelines SPEED Determines the speed of the selected B channel NC The B channel is not connected kbps kbps kbps Default: NC Changing the state of this parameter for one B channel, automatically changes the speed of the second B channel of the same interface. The active channel rate must always be less than the main link data rate. If the resulting total data rate of all the currently active channels in the Kilomux system exceeds the main link rate, a CONFIG ERROR 07 (bandwidth overflow) message is displayed. Configuring KHS.U via the Front Panel 2-5

20 Chapter 2 Module Installation and Operation KHS.U Installation and Operation Manual Table 2-4. KHS.U Channel Parameters (Cont.) Designation Function Values Configuration Guidelines D-CONNECT MODE U_TYPE Controls the transfer of the D channel associated with the selected interface Displays the operating mode of the KHS.U module Determines the operation mode of the "U" interface YES D channel is connected to the main link NO D channel is not connected to the main link Default: NO LT KHS.U module operates in the LTU mode NT KHS.U module operates in the NTU mode T0 Normal operation T1 For application specific customization T2 For future use T3 For future use If after selecting YES, the resulting total data rate of all currently active channels exceeds the main link rate, a CONFIG ERROR 07 (bandwidth overflow) message is displayed This is a read-only parameter, which reflects the position of the KHS.U MODE jumper The operation mode depends on the ISDN interface type 2-6 Configuring KHS.U via the Front Panel

21 Chapter 3 Configuration via Supervision Terminal 3.1 Introduction This chapter provides specific instructions for the configuration of the KHS.U module using a supervision terminal. The configuration activities are performed by means of the management system used to control the Kilomux system. The instructions appearing in this chapter assume you are familiar with the operation and capabilities of the supervision terminal. If necessary, refer to the Kilomux System Installation and Operation Manual for general operating instructions, and for instructions on the execution of other configuration activities. 3.2 Outline of Configuration Procedure The configuration procedure for a new KHS.U includes the following main steps: Inclusion of a KHS.U module not yet installed in the Kilomux database. This allows the pre-programming of the module parameters, so that when the module is installed in the enclosure, it immediately starts operating in the required mode. This function is performed by means of the DEF SYS command. Programming of the module channel parameters, using the DEF CH command. Outline of Configuration Procedure 3-1

22 Chapter 3 Configuration via Supervision Terminal KHS.U Installation and Operation Manual 3.3 Configuring KHS.U If the supervision terminal is not yet connected to the Kilomux enclosure, connect the terminal and start a configuration session in accordance with the Kilomux System Installation and Operation Manual. Inclusion of KHS.U in Database To include the KHS.U module in the database: 1. If the KHS.U module to be configured is not yet installed in the Kilomux enclosure, type: DEF SYS <Enter> The system parameters data form is displayed. A typical form for a Kilomux is shown below. The form presents the current parameter values as defaults. CLK_MASTER CLK_FBACK DWLD_BW_A DWLD_BW_B ML_MODE ML_RECOVER FRAME_MODE INT NONE NO NO SINGLE AUTO AUTO 2. Perform the necessary changes, and press <Enter>. The second line of the system parameters is displayed. A typical data form is shown below. LINK_CLK FLIP_INTEG RESET_VOICE REBUILD_FRAME NONE SHORT DISABLE AUTO 3. Assuming that the only necessary change is the inclusion of a new KHS.U module in the system database, press <Enter>. The third line of the system parameters data form is displayed. A typical data form is shown below. SLOT: TYPE (DB): KHSU.S KHSU.S Note If the required slot number is not shown, press <Enter> once or twice, until the required group of slot numbers is displayed. 4. Change the module type for each required slot as follows: Bring the cursor to the beginning of the required slot number to be changed by pressing the spacebar, and press F or B to scroll among the available selections (KHS.U/S for KHS.U/S or KHS.U/D for KHS.U/D). Note The KHS.U/D module is obsolete. When the required selection is displayed, press the spacebar to move to the next field. 3-2 Configuring KHS.U

23 KHS.U Installation and Operation Manual Chapter 3 Configuration via Supervision Terminal 5. After the required selections are made, press <Enter> to end. The supervision terminal displays the time and date fields, followed by the Kilomux system prompt. Configuring the KHS.U Channel To start the configuration of a specific channel of a KHS.U module: Type: DEF CH i:j <Enter>, where i is the number of the module slot (1 through 12 for Kilomux-2100, or 1 through 4 for Kilomux-2104), and j is the required B channel (1 or 2 for KHS.U/S). The supervision terminal displays the channel configuration data form. A typical data form for a KHS.U module is shown below. SPEED D_CONNECT MODE U_TYPE 64 KBPS NO LT T0 Note For a description of parameters and their allowed range of values, refer to Configuring Channel Parameters in Chapter 2. To change the channel parameters: 1. Bring the cursor to the beginning of the first parameter to be changed by pressing the spacebar. 2. Change the selected parameter by pressing F or B to scroll among the available selections. When the required selection is displayed, press the spacebar to move to the next parameter. 3. After the required parameter values are selected, press <Enter> to end. The supervision terminal displays the time and date fields, followed by the Kilomux system prompt. Configuring KHS.U 3-3

24 Chapter 3 Configuration via Supervision Terminal KHS.U Installation and Operation Manual 3-4 Configuring KHS.U

25 Chapter 4 Alarms and Diagnostics 4.1 Introduction This chapter provides information on module-specific tests, and diagnostic functions of KHS.U. The diagnostic information presented in this chapter supplements the general Kilomux system diagnostics operation instructions (see the Kilomux System Installation and Operation Manual). Local Loopback 4.2 Diagnostic Functions The available diagnostic functions of KHS.U include: Local channel loopback Remote channel loopback. The following sections describe the available test activities. When the local loopback is active, the digital output signal of the modem that processes the analog line signal is connected to the input of the modem receive path, and is returned toward the user equipment, e.g., toward the locally-connected ASM-31, as shown in Figure 4-1. The transmit signal is still sent to the remote Kilomux system. Diagnostic Functions 4-1

26 Chapter 4 Alarms and Diagnostics KHS.U Installation and Operation Manual KHS.U User or Test Equipment ASM-31 Modem KHS.U User or Test Equipment I/O Modules KCL KML KML KCL I/O Modules Local Kilomux Remote Kilomux System Management Figure 4-1. Local Loopback Signal Path Remote Loopback If the remote loopback is activated on the local Kilomux, the line interface of the local KHS.U module returns the receive signal of the tested interface toward the remote Kilomux as shown in Figure 4-2. KHS.U User or Test Equipment Modem KHS.U User or Test Equipment I/O Modules KCL KML KML KCL I/O Modules Local Kilomux Remote Kilomux System Management Figure 4-2. Remote Loopback Signal Path Recommended Test Sequence The loopbacks available on the KHS.U module provide a rapid and efficient way of identifying the general location of a fault at either of the two KHS.U modules connected in a link, or in the external equipment, or in the connections to the channels. The instructions given in this section takes into consideration the user equipment, in this case, the ASM-31 mode. 4-2 Diagnostic Functions

27 KHS.U Installation and Operation Manual Chapter 4 Alarms and Diagnostics If a complaint is received regarding the transmission of data through one of the KHS.U interfaces, perform the following procedure until the problem is located. After each step, continue to the next step only if the specified test is successfully completed. Note If a problem is detected when a connection between two new users is activated for the first time, before starting the troubleshooting procedure described below thoroughly check the timeslot allocation, the configuration of the two Kilomux units that provide the new connection, and the configuration of the ASM-31 modem. When starting the troubleshooting procedure, check whether the KHS.U module LOS indicator is lit, and if possible, check whether the user equipment is synchronized. Request the user to perform a local loopback test on ASM-31 connected to its equipment. If the user equipment does not receive its own signal, the problem is in the connections between the user equipment and ASM-31. After correcting the problem, continue troubleshooting as explained below. If the KHS.U module LOS indicator is Off, activate the local loopback on the corresponding KHS.U interface. The user equipment connected to ASM-31 must receive its own signal. If the signal is not received, replace the local KHS.U module. Activate the remote loopback on the remote module interface. The user equipment connected to the local ASM-31 must receive its own signal. If the signal is received, the problem is in the equipment located at the remote location, or in the connections of the remote user equipment. If the signal is not received when the remote loopback is activated, activate the local main link loop on the local Kilomux unit: If the user equipment connected to the local ASM-31 does not receive its own signal when the main link loop is active, the problem is in the local Kilomux unit If the signal is received when the main link local loopback is activated, activate the remote main link loop. If the user equipment connected to the local ASM-31 does not receive its own signal, the problem is in the remote Kilomux unit. 4.3 Alarm Messages The alarm messages generated by the KHS.U module are displayed either on the Kilomux LCD or on the supervision terminal (see the Kilomux System Installation and Operation Manual for the list of the alarms and their description). Alarm Messages 4-3

28 Chapter 4 Alarms and Diagnostics KHS.U Installation and Operation Manual 4.4 Technical Support Technical support for this product can be obtained from the local distributor from whom it was purchased. For further information, please contact the RAD distributor nearest you or one of RAD's offices worldwide. This information can be found at (offices About RAD > Worldwide Offices; distributors Where to Buy > End Users). 4-4 Technical Support

29 Appendix A Connection Data A.1 Interface Connectors Each interface of the KHS.U module terminates in an RJ-45 connector wired in accordance with Table A-1. Table A-1. RJ-45 Connector Pin Assignment Pin Function 1, 2, 3 Not connected 4 Line wire 5 Line wire 6, 7, 8 Not connected A.2 DC PWR-IN Connector Table A-2 lists the pinout of the KHS.U DC PWR-IN connector. Table A-2. DC PWR-IN Connector Pin Assignment Pin Function 1 Common Ground 2 Not connected 3 Feed Voltage (-48 VDC or -24 VDC) DC PWR-IN Connector A-1

30 Appendix A Connection Data KHS.U Installation and Operation Manual A-2 DC PWR-IN Connector

31 24 Raoul Wallenberg St., Tel Aviv 69719, Israel Tel: , Fax: , Web site: Customer Response Form RAD Data Communications would like your help in improving its product documentation. Please complete and return this form by mail or by fax or send us an with your comments. Thank you for your assistance! Manual Name: KHS.U Publication Number: /06 Please grade the manual according to the following factors: Excellent Good Fair Poor Very Poor Installation instructions Operating instructions Manual organization Illustrations The manual as a whole What did you like about the manual?

32

33 Error Report Type of Error(s) Incompatibility with product or Problem(s): Difficulty in understanding text Regulatory information (Safety, Compliance, Warnings, etc.) Difficulty in finding needed information Missing information Illogical flow of information Style (spelling, grammar, references, etc.) Appearance Other Please list the exact page numbers with the error(s), detail the errors you found (information missing, unclear or inadequately explained, etc.) and attach the page to your fax, if necessary. Please add any comments or suggestions you may have. You are: Distributor End user VAR Other Who is your distributor? Your name and company: Job title: Address: Direct telephone number and extension: Fax number:

34

35

36 INTERNATIONAL HEADQUARTERS: 24 Raoul Wallenberg Street, Tel Aviv 69719, Israel, Tel: Fax: , , NORTH AMERICA HEADQUARTERS: 900 Corporate Drive, Mahwah, N.J , Tel: (201) Toll Free: , Fax: (201) , Publication No /06

HS-RN. 4-Channel Low Speed Data Module with End-to-End Signaling OPERATION MANUAL INSTALLATION AND

HS-RN. 4-Channel Low Speed Data Module with End-to-End Signaling OPERATION MANUAL INSTALLATION AND INSTALLATION AND OPERATION MANUAL HS-RN 4-Channel Low Speed Data Module with End-to-End Signaling Megaplex-2100/2104 Version 12, Megaplex-4100 Version 1.2 The Access Company HS-RN 4-Channel Low Speed

More information

ASMi-52. 2/4-Wire SHDSL Modem FEATURES

ASMi-52. 2/4-Wire SHDSL Modem FEATURES FEATURES Dedicated managed SHDSL modem Operates over 2-wire and 4-wire lines, enabling service over any copper infrastructure Multiplexes of two data streams (E1, Ethernet, Serial) over SHDSL Utilizes

More information

Kilomux Accessories KM-Ringer, Ringer-2000, Ringer-2200N DC Feed and Ring Power Supplies for Voice/Fax and ISDN Modules

Kilomux Accessories KM-Ringer, Ringer-2000, Ringer-2200N DC Feed and Ring Power Supplies for Voice/Fax and ISDN Modules Data Sheet Kilomux Accessories KM-Ringer, Ringer-2000, DC power supplies for Kilomux-2100 voice/fax and ISDN modules Compatible with all voice/fax modules with FXS interface DC feed (battery) and ringing

More information

MEGAPLEX-2100 MODULE LS-2A. 10/6-Channel Sync/Async Low Speed Data Module for X.50, X.58 or SDM Multiplexing Installation and Operation Manual.

MEGAPLEX-2100 MODULE LS-2A. 10/6-Channel Sync/Async Low Speed Data Module for X.50, X.58 or SDM Multiplexing Installation and Operation Manual. MEGAPLEX-200 MODULE LS-2A 0/6-Channel Sync/Async Low Speed Data Module for X50, X58 or SDM Multiplexing Installation and Operation Manual Notice This manual contains information that is proprietary to

More information

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module

Kilomux-2100/2104 KVF.6 E1/T1 Voice Compression Module Data Sheet Kilomux-2100/2104 KVF.6 Half or full PBX E1/T1 trunk compression Up to 186 voice channels in a single Kilomux-2100 chassis Group III Fax relay at up to 14.4 kbps, with automatic rate fallback

More information

MARKET SEGMENTS AND APPLICATION

MARKET SEGMENTS AND APPLICATION Product page > Data Sheet Managed SHDSL.bis modem transmitting full-duplex at data rates of up to 5.7 Mbps over 2-wire, and 11.4 Mbps over 2/4-wire lines Dual Bearer mode enabling or V.35 service combination

More information

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber

More information

Kilomux-2100/2104 KVF.8 8-Channel Analog Voice Compression Module

Kilomux-2100/2104 KVF.8 8-Channel Analog Voice Compression Module Data Sheet Kilomux-2100/2104 KVF.8 Up to 96 analog voice channels in a single Kilomux-2100/2104 chassis Group III Fax relay at up to 14.4 kbps, with automatic rate fallback V.22 bis and V.32 bis modem

More information

2/4-wire SHDSL Modem/Multiplexer

2/4-wire SHDSL Modem/Multiplexer Data Sheet ASMi-52 SHDSL modem for effective provisioning of TDM and Ethernet data services at the rates of up to 4.6 Mbps Dedicated managed SHDSL modem for Ethernet, E1 and serial Ethernet and E1 or serial

More information

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer Data Sheet Kilomux-2100/2104 Data, Voice, Fax and LAN Integrating Modular Multiplexer Maximized utilization of main-link bandwidth and high-quality low bit rate voice Fractional E1/T1, switched or leased

More information

ASMi-52 2/4-wire SHDSL Modem/Multiplexer

ASMi-52 2/4-wire SHDSL Modem/Multiplexer Where to buy > See the product page > Data Sheet ASMi-52 Plastic Enclosure Metal Enclosure Rail-mount Metal Enclosure Dedicated managed SHDSL modem for Ethernet, E1 and serial services over 2- or 4-wire

More information

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES Modular integrating access multiplexer for data, voice, fax and LAN Maximized utilization of main-link bandwidth and high quality low bit

More information

Installation and Operation Manual KVF.8. 8-Channel Analog Voice Compression Module KILOMUX-2100 MODULE

Installation and Operation Manual KVF.8. 8-Channel Analog Voice Compression Module KILOMUX-2100 MODULE Installation and Operation Manual KVF.8 8-Channel Analog Voice Compression Module KILOMUX-2100 MODULE KVF.8 8-Channel Analog Voice Compression Module Installation and Operation Manual Notice This manual

More information

FOMi-40 Fiber Optic Modem with Remote Management

FOMi-40 Fiber Optic Modem with Remote Management Data Sheet FOMi-40 Provides a secure and long-range data link of up to 100 km (62 mi) Selectable data rates from 56 to 2048 kbps Multimode or single mode operation Extended transmission range up to 100

More information

Installation and Operation Manual VF-30/VF-60. Single/Dual E1 Digital Voice Compression Modules. Megaplex-2100 Version 11 MEGAPLEX-2100 MODULES

Installation and Operation Manual VF-30/VF-60. Single/Dual E1 Digital Voice Compression Modules. Megaplex-2100 Version 11 MEGAPLEX-2100 MODULES Installation and Operation Manual VF-30/VF-60 Single/Dual E1 Digital Voice Compression Modules Megaplex-2100 Version 11 MEGAPLEX-2100 MODULES VF-30/VF-60 Single/Dual E1 Digital Voice Compression Modules

More information

ASMi-54 SHDSL.bis Modem

ASMi-54 SHDSL.bis Modem Where to buy > See the product page > Metal Enclosure Plastic Enclosure Rail-mount Metal Enclosure Access with Ethernet Ring capabilities SHDSL.bis managed modem operating at full-duplex data rates of

More information

Optimux-34, Optimux-25

Optimux-34, Optimux-25 Data Sheet Optimux-34, Optimux-25 16-Channel E1/T1, Ethernet or Data over E3 or Fiber Multiplexers Up to 16 E1/T1 links and high-speed data or Ethernet traffic multiplexed into fiber opt7ic uplink E3 copper

More information

ASMi-54L SHDSL.bis Modem

ASMi-54L SHDSL.bis Modem Where to buy > See the product page > Data Sheet ASMi-54L Managed modem transmitting full-duplex at data rates of up to 5.7 Mbps over 2-wire and 11.4 Mbps over 2/4-wire lines High-speed Ethernet and E1

More information

Gmux Modular TDMoIP Gateway FEATURES

Gmux Modular TDMoIP Gateway FEATURES FEATURES Carrier-class modular TDMoIP gateway, extending high capacity TDM traffic over packet-switched networks (PSNs) Operates opposite other members of RAD s TDMoIP family of products, offering a complete

More information

Where to buy > Product page >

Where to buy > Product page > Where to buy > Product page > Data Sheet.bis Modem.bis managed modem operating at full-duplex data rates of up to 5.7 Mbps per copper pair Ethernet service over 8-wire line of up to 22.8 Mbps in Point-to-Point,

More information

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES

Kilomux-2100/2104. Data, Voice, Fax and LAN Integrating Modular Multiplexer FEATURES -2100/2104,, and LAN Integrating Modular Multiplexer FEATURES Modular integrating access multiplexer for data, voice, fax and LAN Advanced voice compression techniques maximize utilization of main link

More information

ASMi-54L. Data Sheet. SHDSL.bis Modem

ASMi-54L. Data Sheet. SHDSL.bis Modem Product page > Data Sheet Modem Managed modem transmitting full-duplex at data rates of up to 5.7 Mbps over 2-wire and 11.4 Mbps over 4-wire lines Dual Bearer mode for E1 and Ethernet HDLC Extended rates

More information

Optimux-34 Fiber Optic Multiplexer

Optimux-34 Fiber Optic Multiplexer Data Sheet Optimux-34 Multiple E1, Ethernet, or High-speed Data over E3 or Fiber, up to 110 km (68 miles) Up to 16 E1 links, high-speed data, and Ethernet traffic multiplexed into one E3 copper or fiber

More information

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES

FCD-155. STM-1/OC-3 Terminal Multiplexer FEATURES FEATURES SDH/SONET terminal multiplexer for grooming LAN and legacy traffic (TDM) over SDH/SONET networks Demarcation point between the carrier and the customer networks GFP (G.7041), LAPS (X.85/86) encapsulation

More information

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company

Data Sheet SRM-3A. Ultra-Miniature Isolated Short-Range Async Modem. The Access Company Data Sheet SRM-3A Ultra-Miniature Isolated Short-Range Async Modem The Access Company Features Asynchronous transmission of up to 19.2 kbps Transmission range of up to 13 km (8 miles) Ultra-miniature modem

More information

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers

Megaplex-2100/2104. Data Sheet. Modular Integrated Access Multiplexers Product page > Data Sheet -2100/2104 Multiple n x 64 kbps, E1/T1 or fractional E1/T1 main links, with combined TDM capacity of up to 8 Mbps (124 timeslots) 10/100-Mbps IP access link for transparent circuit

More information

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units

FCD-E1, FCD-T1 E1/T1 or Fractional E1/T1 Access Units FCD-E1, FCD-T1 Access units for E1/T1 or fractional E1/T1 services Several data ports with selectable sync data rates: n 56/64 kbps Optional sub-e1/t1 drop-and-insert port for PBX connectivity Fail-safe

More information

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units

FCD-E1LC, FCD-T1LC Managed E1/T1 or Fractional E1/T1 Access Units Data Sheet FCD-E1LC, FCD-T1LC Managed TDM multiplexers for access to full or fractional E1/T1 services Managed access units for E1/T1 or fractional E1/T1 service E1/T1 main link and sublink support framed

More information

Installation Guide. RADview-EMS/NGN (PC) PC-Based Element Management System for NGN Applications Version 1.8

Installation Guide. RADview-EMS/NGN (PC) PC-Based Element Management System for NGN Applications Version 1.8 RADview-EMS/NGN (PC) PC-Based Element Management System for NGN Applications Version 1.8 RADview-EMS/NGN (PC) PC-Based Element Management System for NGN Applications Version 1.8 Installation Guide Notice

More information

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters

RICi-E1, RICi-T1 Fast Ethernet over E1/T1 Intelligent Converters Connect Fast Ethernet LANs over E1 or T1 circuits Wire-speed packet forwarding 4 levels of QoS, based on four VLAN priority queues in accordance with 802.1p and IP Precedence Inband and out-of-band management

More information

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company

Data Sheet SRM-6A. Short-Range Asynchronous Modem. The Access Company Data Sheet SRM-6A Short-Range Asynchronous Modem The Access Company Features Asynchronous, full-duplex modem Data rates of up to 19.2 kbps SRM-6A transmission range of up to 8 km (5.0 mi) (for 24 AWG)

More information

FCD-E1E Managed E1 and Fractional E1 Access Device

FCD-E1E Managed E1 and Fractional E1 Access Device FCD-E1E E1 main link and sublink supporting both framed and unframed signals One data port with selectable sync data rates of n 64 kbps Optional sub-e1 drop-and-insert port Optional Ethernet 10/100BaseT

More information

ASMi-54 SHDSL.bis Modem

ASMi-54 SHDSL.bis Modem Where to buy > See the product page > Data Sheet ASMi-54 Metal Enclosure Rail-mount Metal Enclosure Plastic Enclosure 19-inch Metal Enclosure High-end SHDSL.bis multiservice access equipment SHDSL.bis

More information

KVF.8 KILOMUX-2100 MODULE. 8-Channel Analog Voice Compression Module. Installation and Operation Manual

KVF.8 KILOMUX-2100 MODULE. 8-Channel Analog Voice Compression Module. Installation and Operation Manual Installation and Operation Manual KVF.8 8-Channel Analog Voice Compression Module KILOMUX-2100 MODULE KVF.8 8-Channel Analog Voice Compression Module Installation and Operation Manual Notice This manual

More information

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high order legacy traffic (TDM) over SDH/SONET networks Any Traffic Over Fiber Multiplexes up to three E3 or T3 data channels using

More information

IPmux-1E TDM Pseudowire Access Gateway

IPmux-1E TDM Pseudowire Access Gateway Data Sheet IPmux-1E TDM circuit emulation over packet-switched networks Transporting E1, T1, ISDN and analog phone traffic over packet-switched networks Four FXS, FXO or E&M voice ports for standard analog

More information

OPERATION MANUAL INSTALLATION AND HS-ETH. 1/2/4-Channel Ethernet Bridge/Router Modules. Megaplex-2100/2104 Version 10. The Access Company

OPERATION MANUAL INSTALLATION AND HS-ETH. 1/2/4-Channel Ethernet Bridge/Router Modules. Megaplex-2100/2104 Version 10. The Access Company INSTALLATION AND OPERATION MANUAL HS-ETH 1/2/4-Channel Ethernet Bridge/Router Modules Megaplex-2100/2104 Version 10 The Access Company HS-ETH 1/2/4-Channel Ethernet Bridge/Router Modules Megaplex-2100/2104

More information

LA-140. Advanced ATM IAD FEATURES

LA-140. Advanced ATM IAD FEATURES Advanced IAD FEATURES Offers voice, data and LAN to small and medium size businesses over single access line On the user side, supports up to 12 modular analog voice channels, 12 ISDN S0, E1/T1 port, a

More information

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router

E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router Data Sheet E1/T1 or Fractional E1/T1 Modular Access Device with Integrated Router Modular Integrated Access Device (IAD), providing bundled data, IP and telephony services over E1/T1 access lines E1/T1

More information

Optimux-108, Optimux-106

Optimux-108, Optimux-106 Where to buy > Product page > Data Sheet Optimux-108, Multiplexer for 4E1/4T1 and Ethernet or Serial Data Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link Various fiber

More information

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 E3/T3 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high-order legacy traffic (TDM) over SDH/SONET networks Up to three E3 or T3 data channels multiplexed using a single hot-swappable

More information

Vmux-400 GSM A-bis/A-ter Optimization Gateway

Vmux-400 GSM A-bis/A-ter Optimization Gateway Data Sheet Vmux-400 GSM A-bis/A-ter interface optimization of voice with up to 3:1 average bandwidth optimization Connects up to two E1/T1 digital GSM ports over a single E1/T1, serial, or Ethernet 10/100BaseT

More information

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES

IPmux-11. TDMoIP Gateway DESCRIPTION FEATURES IPmux-11 DESCRIPTION FEATURES TDMoIP CPE (Customer Premises Equipment) for the small and medium-sized enterprise sites, offering TDM leased line extension over a packet switched network and controlled

More information

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers

Optimux-108, Optimux-106 Four-Channel E1/T1 and Ethernet Multiplexers Data Sheet Optimux-108, Optimux-106 Fiber Multiplexers, Transmit Any Traffic over Fiber Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link Various fiber interfaces: multimode,

More information

OPERATION MANUAL INSTALLATION AND ML-8E1, ML-8T1. 8-Port Main Link E1 and T1 Modules. Megaplex-2100/2104 Version 12. The Access Company

OPERATION MANUAL INSTALLATION AND ML-8E1, ML-8T1. 8-Port Main Link E1 and T1 Modules. Megaplex-2100/2104 Version 12. The Access Company INSTALLATION AND OPERATION MANUAL ML-8E1, ML-8T1 8-Port Main Link E1 and T1 Modules Megaplex-2100/2104 Version 12 The Access Company ML-8E1, ML-8T1 8-Port Main Link E1 and T1 Modules Megaplex-2100/2104

More information

SFP Transceivers Small Form-Factor Pluggable Transceivers

SFP Transceivers Small Form-Factor Pluggable Transceivers Data Sheet SFP Transceivers Fiber optic/electrical transceivers and System-on-an-SFP miniature converters Fiber optic or electrical transceiver units, providing pluggable interfaces according to known

More information

Optimux-108, Optimux-106

Optimux-108, Optimux-106 Product page > Data Sheet Optimux-108, Multiplexer for 4E1/4T1 and Ethernet or Serial Data Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic link Various fiber interfaces: multi,

More information

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer Data Sheet FCD-155 Transports LAN and TDM traffic over SDH/SONET networks STM-1/OC-3 PDH/Ethernet terminal multiplexer grooms LAN and legacy (TDM) traffic over SDH/SONET networks 10/100BaseT and GbE (Gigabit)

More information

Optimux-1032, Optimux-1025

Optimux-1032, Optimux-1025 Where to buy > Product page > Data Sheet Optimux-1032, Optimux-1025 Fiber Optic Multiplexer for 16 E1/T1 and Gigabit Ethernet Multiplexes up to 16 E1/T1 with up to 3x10/100/1000 user Ethernet traffic over

More information

Vmux-110. Voice Trunking Gateway FEATURES

Vmux-110. Voice Trunking Gateway FEATURES Vmux-110 FEATURES Integrates voice and data over packet networks Connects one E1/T1 digital or four/eight (FXS/FXO/E&M) analog voice ports over a serial, TDM or 10/100BaseT uplink Second Ethernet port

More information

Optimux-108, Optimux-106

Optimux-108, Optimux-106 Where to buy > See the product page > Data Sheet OP-108 RAD Optimux-108 Fiber Multiplexers, Transmit Any Traffic over Fiber Four E1 or T1 channels and Fast Ethernet link multiplexed over a fiber optic

More information

RAD KILOMUX-2100/2104

RAD KILOMUX-2100/2104 Page 1 of 10 RAD KILOMUX-2100/2104 FEATURES Integrating access multiplexer for data, voice, fax and LAN Maximizes utilization of main link bandwidth Main link data rates from 9.6 to 768 kbps Connects to

More information

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications.

This provides an easily configurable solution, flexible enough to meet the specific requirements of a broad range of applications. Where to buy > Product page > Data Sheet, L Up to 28 T1 or 21 E1 channels multiplexed into a single 45 Mbps data stream Combination of T1 and E1 channels Transmission over coax or fiber optic cable Range

More information

SFP Transceivers Small Form-Factor Pluggable Transceivers

SFP Transceivers Small Form-Factor Pluggable Transceivers Data Sheet SFP Transceivers Fiber optic/electrical transceivers and System-on-an-SFP miniature converters Fiber optic or electrical transceiver units, providing pluggable interfaces according to known

More information

Vmux-210 Analog Voice Trunking Gateway

Vmux-210 Analog Voice Trunking Gateway Where to buy > See the product page > Unique TDMoIP multiplexing, together with various voice compression algorithms, provides up to 16:1 compression for effective bandwidth utilization Fully transparent

More information

- 10/100/1000T SFP based port - 10/100BaseT RJ-45 port - Auto crossing - Autonegotiation per IEEE 802.3ab

- 10/100/1000T SFP based port - 10/100BaseT RJ-45 port - Auto crossing - Autonegotiation per IEEE 802.3ab November 4, 2015 : General Availability Ruggedized SCADA-Aware Router Gateway is an Ethernet router gateway, a member of RAD s SecFlow suite of ruggedized Ethernet family. With a unique built-in packet-processing

More information

Installation and Operation Manual ML-IP. TDMoIP Main Link Module. MP-2100 Version 11 MEGAPLEX-2100 MODULE

Installation and Operation Manual ML-IP. TDMoIP Main Link Module. MP-2100 Version 11 MEGAPLEX-2100 MODULE Installation and Operation Manual ML-IP TDMoIP Main Link Module MP-2100 Version 11 MEGAPLEX-2100 MODULE ML-IP TDMoIP Main Link Module for MP-2100 Version 11 Installation and Operation Manual Notice This

More information

Atrie WireSpan 620. User's Manual

Atrie WireSpan 620. User's Manual Atrie WireSpan 620 User's Manual WireSpan 620 Fractional E1/Ethernet Access Unit Installation and Operation Manual (Version 1.00) CONTENTS CHAPTER 1 Introduction.. 1-1 CHAPTER 2 Installation and Setup..

More information

IPmux-16 TDM Pseudowire Access Gateway

IPmux-16 TDM Pseudowire Access Gateway Data Sheet IPmux-16 TDM circuit emulation over packet-switched networks Robust TDM emulation over packet networks Single or dual 10/100BaseT or 100BaseFx uplink to the network, with redundancy at the Ethernet

More information

ETX-102 Carrier Ethernet Demarcation Device

ETX-102 Carrier Ethernet Demarcation Device Data Sheet ETX-102 Smart demarcation point between the service provider and customer networks SLA monitoring to assure delivery of contracted Ethernet services VLAN bridging and stacking with P-bit, DSCP,

More information

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options:

Modular E1 or Fractional E1 Access Unit. Dial-out for alarm report The E1 main link can be supplied with the following options: FEATURES E1 or Fractional E1 access unit Supports one data port with selectable sync data rates: n x 56, n x 64 kbps Optional sub-e1 drop & insert port for PABX connectivity Single slot supports MEGAPLEX

More information

RADview-EMS/TDM (Unix)

RADview-EMS/TDM (Unix) RADview-EMS/TDM (Unix) Element Management System for TDM Applications Version 1.7 RADview-EMS/TDM (Unix) Element Management System for TDM Applications Version 1.7 Installation Guide Notice This manual

More information

Megaplex-2100/2104 Modular Integrated Access Multiplexers

Megaplex-2100/2104 Modular Integrated Access Multiplexers Data Sheet Megaplex-2100/2104 Sub-DS0 multiplexer providing voice, data, Ethernet, and other unique services (teleprotection, omnibus) Multiple n x 64 kbps, SHDSL, E1/T1 or fractional E1/T1 main links,

More information

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... User's Manual Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... 8 Important Safety Instructions... 9 Installation...11

More information

Vmux-2120 Voice Trunking Gateway

Vmux-2120 Voice Trunking Gateway Data Sheet Vmux-2120 Unique TDMoIP multiplexing, with various voice compression algorithms, provides up to 16:1 compression for effective bandwidth utilization Two channelized uplink ports for point-to-multipoint

More information

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES

ACE-2002, ACE-2002E. Multiservice Access Concentrators/ ATM Network Termination Units FEATURES Multiservice Access Concentrators/ ATM Network Termination Units FEATURES Multiservice/ATM network demarcation device or access concentrator (ACE-2002), cellular access concentrator () Offer converged

More information

ASMi Wire MSDSL Modem With Remote Management Installation and Operation Manual. Notice

ASMi Wire MSDSL Modem With Remote Management Installation and Operation Manual. Notice ASMi-51 2-Wire MSDSL Modem With Remote Management Installation and Operation Manual Notice This manual contains information that is proprietary to RAD Data Communications. No part of this publication may

More information

Airmux-400, Airmux-5000 Optional Accessories

Airmux-400, Airmux-5000 Optional Accessories Data Sheet, Optional Accessories Airmux-IDU-H Airmux-HSSU Airmux-OPOE/DC Aimux-MHS-kit Airmux-PoE/GbE Airmux-Lightning-Protection Aimux-PoE/GBE/DC Aimux-PoE/DC Airmux-GSU Airmux-FE-Repeater , Optional

More information

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company

DXC /1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix. Data Sheet. Multiservice Access Node. The Access Company Data Sheet 3/1/0 modular multiservice cross connect access node up to 1.2 Gbps matrix Modular Carrier class 3/1/0 non-blocking cross-connect 256 Mbps to 1.2 Gbps matrix Expandable (stackable) 6U-high units

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05

RADview. Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L RAD Data Communications Publication 07/05 RADview Element Management System Optimux-4E1, Optimux-4T1 Optimux-4E1L, Optimux-4T1L 1994 2005 RAD Data Communications Publication 07/05 Contents Chapter 1. Introduction 1.1 Overview... 1-1 General...1-1

More information

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer Where to buy > See the product page > Data Sheet Groomed LAN and legacy (TDM) traffic over SDH/SONET networks VLAN and point-to-multipoint switching Transports LAN and TDM traffic over SDH/SONET networks

More information

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router

E1/T1 or Fractional E1/T1 Access Unit with Integrated Router Where to buy > See the product page > Data Sheet FCD-IP E1/T1 or Fractional E1/T1 Access Unit with Integrated Router Integrated access device providing bundled services over E1/T1 access lines Provides

More information

Vmux-110 Voice Trunking Gateway for Remote Sites

Vmux-110 Voice Trunking Gateway for Remote Sites Where to buy > See the product page > Data Sheet Vmux-110 Compressing one E1/T1 or four/eight analog (FXS/FXO/E&M) voice ports, and transmitting them over a serial, fractional E1/T1, or a 10/100BaseT uplink

More information

IPmux-1E. TDMoIP Gateway FEATURES

IPmux-1E. TDMoIP Gateway FEATURES IPmux-1E FEATURES TDMoIP gateway enabling E1, T1, ISDN, and analog phone communication over asynchronous IP and Ethernet networks Framed (full or fractional) and unframed E1/T1 user traffic Four FXS/E&M/FXO

More information

Multiservice Network Termination Unit

Multiservice Network Termination Unit Order from Cutter Networks Ph:727-398-5252/Fax:727-397-9610 www.bestdatasource.com Data Sheet Extending the reach of Ethernet LANs and TDM services over ATM networks Transparent LAN services (TLS) and

More information

Using RAD Vmux voice trunking over FleetBroadband

Using RAD Vmux voice trunking over FleetBroadband Using RAD Vmux voice trunking over FleetBroadband Version 01 22 October 2007 inmarsat.com/fleetbroadband Whilst the information has been prepared by Inmarsat in good faith, and all reasonable efforts have

More information

F271XA Fiber-Optic Telephone Modem Technical Manual

F271XA Fiber-Optic Telephone Modem Technical Manual F271XA Fiber-Optic Telephone Modem Technical Manual Revision B August 2011 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY

More information

RC702-FX Ethernet over SDH User Manual

RC702-FX Ethernet over SDH User Manual RC702-FX Ethernet over SDH User Manual Raisecom Technology Co., Ltd 1. Caution Please carefully read the following precautions before installing and deploying RC702-FX equipment, and operate strictly according

More information

SFP/XFP Transceivers Small Form-Factor Pluggable Transceivers

SFP/XFP Transceivers Small Form-Factor Pluggable Transceivers Where to buy > See the product page > Data Sheet SFP/XFP Transceivers Fiber optic/electrical transceivers Fiber optic or electrical transceiver units, providing pluggable interfaces according to known

More information

FCD-155 STM-1/OC-3 Terminal Multiplexer

FCD-155 STM-1/OC-3 Terminal Multiplexer Data Sheet FCD-155 Transports LAN and TDM traffic over SDH/SONET networks Groomed LAN and legacy (TDM) traffic over SDH/SONET networks VLAN and point-to-multipoint switching Ethernet traffic mapped to

More information

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES

FCD-155. STM-1/OC-3 Terminal Multiplexer DESCRIPTION FEATURES DESCRIPTION FEATURES STM-1/OC-3 PDH/Ethernet terminal multiplexer for grooming LAN and legacy (TDM) traffic over SDH/SONET networks Ethernet traffic maps to: One VC-3/VC-4/STS-1 Up to 3 VC-3/STS-1 Up to

More information

FCD-155E STM-1/OC-3 Add/Drop Multiplexer

FCD-155E STM-1/OC-3 Add/Drop Multiplexer Data Sheet FCD-155E STM-1/OC-3 add/drop multiplexer that transports LAN and traditional (TDM) traffic over SDH/SONET networks STM-1/OC-3 PDH/Ethernet add/drop multiplexer for grooming LAN and legacy (TDM)

More information

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727.

AREA CODE CHANGE. Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. AREA CODE CHANGE Please note that the area code for Paradyne Corporation in Largo, Florida has changed from 813 to 727. For any Paradyne telephone number that appears in this manual with an 813 area code,

More information

LRS-12. "Last Mile" SNMP Modem Rack FEATURES

LRS-12. Last Mile SNMP Modem Rack FEATURES "Last Mile" SNMP Modem Rack FEATURES Accommodates any combination of 12 HDSL, copper or fiber optic modem cards SNMP management agent Supports modems with or without integrated SNMP agent Management running

More information

ACE-202/2002/2002E ATM STM-1, STM-4, IMA and ATM UNI Modules

ACE-202/2002/2002E ATM STM-1, STM-4, IMA and ATM UNI Modules Data Sheet ACE-202/2002/2002E ATM Fiber optic and electrical ATM modules for a wide variety of multiservice applications Used as I/O to public ATM switches or private ATM devices Protection capabilities

More information

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM

OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM OPERATOR MANUAL OSD136 SYNCHRONOUS FIBER OPTIC RS232 MODEM Page 2 of 16 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES

HS-2. MEGAPLEX-2000/2100 Module. 2-Channel High Speed Data Module DESCRIPTION FEATURES MEGAPLEX-2000/2100 Module HS-2 2-Channel High Speed Data Module FEATURES Supports two high speed data channels Programmable data rates up to 1,984 kbps in any multiple of 64 or 56 kbps User-selectable

More information

IPmux-24 TDM Pseudowire Access Gateway

IPmux-24 TDM Pseudowire Access Gateway IPmux-24 TDM circuit emulation over packet-switched networks Comprehensive support for pseudowire/circuit emulation standards including TDMoIP, CESoPSN, SAToP and HDLCoPSN Industry-leading adaptive clock

More information

FCD-155E STM-1/OC-3 Add-Drop Multiplexer

FCD-155E STM-1/OC-3 Add-Drop Multiplexer Where to buy > See the product page > Data Sheet STM-1/OC-3 add/drop multiplexer that transports LAN and traditional (TDM) traffic over SDH/SONET networks STM-1/OC-3 PDH/Ethernet add/drop multiplexer for

More information

Moxa TCC-100 Series User s Guide

Moxa TCC-100 Series User s Guide Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The

More information

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual Revision A January 2014 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since

More information

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Wideband Voltage Input 3B40 / 3B41 FEATURES Interfaces, amplifies, protects& filters wide-bandwidth (h0 khz) single-channel analog voltage inputs. Module provides simultaneous precision voltage

More information

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Isolated Linearized RTD Input 5B34 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Isolated Linearized RTD Input 5B34 FEATURES Amplifies, Protects, Filters, and Isolates Analog Input. Linearize a wide variety of 2 & 3 wire RTDs. (True 4-wire RTD measurements are provided by the 5B35).

More information

OPERATION MANUAL INSTALLATION AND MPW-1. TDM Pseudowire Access Gateway. MP-4100 Version 2.0. The Access Company

OPERATION MANUAL INSTALLATION AND MPW-1. TDM Pseudowire Access Gateway. MP-4100 Version 2.0. The Access Company INSTALLATION AND OPERATION MANUAL MPW-1 TDM Pseudowire Access Gateway MP-4100 Version 2.0 The Access Company MPW-1 TDM Pseudowire Access Gateway MP-4100 Version 2.0 Installation and Operation Manual Notice

More information

T3 Interface Converters

T3 Interface Converters MT1103A JULY 2003 MT1103A-DC T3 Interface Converters CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day,

More information

Synway SSW Series FXM3201P(SSW) AST Analog Voice Board. Special-for-Switch. Version 1.0. Synway Information Engineering Co., Ltd.

Synway SSW Series FXM3201P(SSW) AST Analog Voice Board. Special-for-Switch. Version 1.0. Synway Information Engineering Co., Ltd. Synway SSW Series FXM3201P(SSW) AST Analog Voice Board Special-for-Switch Version 1.0 Synway Information Engineering Co., Ltd www.synway.net Contents Contents... ii Copyright Declaration... iii Revision

More information

Packet Switching Application Guide Version 5.2

Packet Switching Application Guide Version 5.2 Installation and Operation Manual Packet Switching Application Guide Version 5.2 Packet Switching Application Guide Version 5.2 Notice This manual contains information that is proprietary to RAD Data

More information

Moxa TCC-100 Series Hardware Installation Guide

Moxa TCC-100 Series Hardware Installation Guide Moxa TCC-100 Series Hardware Installation Guide Twelfth Edition, January 2015 www.moxa.com/product 2015 Moxa Inc. All rights reserved. P/N: 1802001000319 Moxa TCC-100 Series Hardware Installation Guide

More information

ETX-201A Carrier Ethernet Demarcation Device

ETX-201A Carrier Ethernet Demarcation Device Data Sheet ETX-201A Carrier Demarcation Device Smart demarcation point between the service provider and customer networks Carrier demarcation device delivering business services over fiber infrastructure

More information