1 Geist Upgradeable 2 (GU2) Rack Power Distribution Unit (PDU) GUIDE SPECIFICATIONS 1.0 GENERAL 1.1 SUMMARY This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty, upgradeable rack power distribution system. The PDU, hereafter referred to as GU2, provides high-quality distribution and management of AC power to mission critical equipment. 1.2 STANDARDS GU2 is designed in accordance with the applicable sections of the following regional documents and standards: NORTH AMERICA 120V, 120/208V, 208V, 240V, 240/415V Units (Single & Three Phase) - UL , 2 nd Edition, : Information Technology Equipment - CAN/CSA-C22.2 No , 2 nd Edition, : Information Technology Equipment - FCC, Title 47, Part 15 Subpart B for Class A operation as defined by ANSI Standard C GR-63-CORE & MIL-STD-910G - RoHS Compliant EUROPE 230V, 230/400V Units (Single and Three Phase) - IEC :2005 (2 nd Edition); Am1: Am2:2013: Information Technology Equipment /35/EU Low-Voltage Directive (LVD) - European Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment (RoHS2) - SR332i04GR-63-CORE & MIL-STD-910G - RoHS 2 and WEEE Compliant JAPAN - PSE AUSTRALIA and NEW ZEALAND - RCM 1.3 DESCRIPTION The Geist Upgradeable (GU) line of PDUs provides the flexibility to deliver basic, integrated power distribution units today with the option of field upgrading the technology as needs evolve. To establish this upgrade path, Geist offers an Interchangeable Monitoring Device (IMD), which is a hot-swappable, intelligence module containing features such as ethernet port(s), USB, LED display, sensor ports, etc. While the main electrical components of the PDU (input cord, chassis, outlets) remain the same, the IMD can be updated to support higher tier product features and functionality. With the IMD, users can upgrade to the latest monitoring and control technology without replacing the PDU. The hot-swappable IMD can be upgraded in a few simple steps without interrupting power to critical equipment. GU2 is the second-generation of the GU product line and includes Switched, Outlet Monitored, and Switched plus Outlet Monitored options. GU2 provides scalable global power distribution by means of compatibility with a variety of North/Central American, European and International input cords,
2 connectors and outlets. The GU2 PDU delivers flexibility and lower total cost of ownership when compared to a non-upgradeable PDU option. The GU2 Monitored and Switched PDUs offer real-time power monitoring, which includes data logging and management for voltage, real power, apparent power, power factor and kilowatt hours, via secure web (HTTPS), SNMP, JSON API, or Command Line Interface (CLI). The networkconnected PDUs transmit notifications of any breach in user-specified thresholds for power and climate conditions, such as potential overloads, before critical IT mains breakers trip. The Switched GU2 PDU additionally provides the ability to remotely turn on, turn off or reboot power to each outlet. 1.4 PDU COMPONENTS GU2 Rack PDUs are manufactured with high quality components and electronic sub-assemblies and are assembled in an ISO 9001 (2015) certified production facility, making them highly reliable. Geist PDUs receive rigorous environmental and mechanical testing to ensure product longevity METAL CHASSIS Geist PDU chassis are manufactured by Geist with locally sourced steel. Complete manufacturing and production of the chassis includes metal punching, bending, press fitting and painting with a scratch resistant powder coat finish. Once the chassis are completed to Geist s specifications, all other components and electrical sub-assemblies are installed within the chassis at the same Geist facility. The GU2 PDU chassis is available in multiple colors, including black, white, yellow, blue, orange, red and green. Other colors may be available upon request TECHNOLOGY The GU PDU has three main technology assemblies: 1. Input board The interface assembly that provides connectivity to and transition of the facility input power to the PDUs circuits. The input board also contains input power measurement circuitry and the product factory assembly profile. 2. Interchangeable Monitoring Device (IMD) Is the control module which provides the interface between the user network and PDU functional data and is the main component that makes the GU2 PDU upgradeable. The IMD module is hot swappable; it can be replaced without interrupting the power at the outlet level and provides flexible connectivity to match current customer needs of network and monitoring options. 3. Outlet board(s) These sub-assemblies incorporate outlet level monitoring and control circuitry. Each outboard board supports six outlets and communicates back into to the IMD s host board by way of the Geist Module Communications bus. The outlet boards are designed with programmable time actuated bi-stable magnetic latching relays, which saves energy and reduces operating costs COMMUNICATION GU2 PDUs include local and remote connectivity, via network connection or mobile app, and provide data for overall and per outlet power usage; Amps (A), Volts (V), Real power (W), Apparent Power (VA), Power Factor (pf) and energy consumption (kwh). Note: outlet level data is available via the GUI, SNMP, JSON API or external management software. The GU2 rack PDU is IP addressable over a TCP/IP Ethernet network (10/100MB; full duplex) for remote control and monitoring. The network interface supports ARP, IPv4, IPv6, ICMP, ICMPv6, NDP, TCP, UDP, RSTP, STP, DNS, HTTP, HTTPS (TLSv1.2), SMTP, SMTPS, DHCP, SNMP (v1/v2c/v3), LDAP, NTP, SSH and Syslog protocols. GU2 supports a fault-tolerant daisy chain of up to 40 devices using the Rapid Spanning Tree Protocol (RSTP). Geist Rev 02/2018 2
3 GU2 PDUs provide billing grade power data (A, V, VA, W, kw, pf) for Phases and/or Outlets with +/- 1% accuracy, as well as +/- 2% accuracy per breaker current (A) accuracy. The GU2 offers support for TLSv1.2 for secure access to GUI and to multi-level local user accounts (read only, control, admin), along with directory-based authentication systems such as LDAP RECEPTACLES/OUTLETS The GU2 PDU uses Geist patented U-Lock locking IEC receptacles that are color coded for easy identification of circuits/phases and to assist with phase load balancing. Locking receptacles are compatible with standard cord sets, no vendor specific or special cords are required. Receptacle ratings: NEMA 5-20R Type U-Lock Locking IEC C13 U-Lock Locking IEC C19 125VAC, 20A Ratings 250VAC, 10A (UL & CSA 15A, 250VAC) 250VAC, 16A (UL & CSA 20A, 250VAC) INTERNAL WIRING The GU2 outlets are wired based on customer needs and independently configured based on input phase number and type. Outlets can be phase interweaved and selectively wired as L-L or L-N. Phase interweaving simplifies rack level phase balancing by sequentially alternating input power phases between outlets. The GU product family is wired for upgradability, with each generation of Geist GU PDU offering a higher level of upgradeability. GU First generation PDUs (GU) can be upgraded from Basic to Metered to Monitored. For example, Basic PDUs have no local or remote communication, but with an IMD replacement, they can be upgraded to a local Metered PDU or a local and remote unit-level Monitored PDU. GU2 Second generation PDUs (GU2) also are built and configured with an upgradeable option via firmware update. For example, Switched PDUs can be upgraded, via a simple firmware download process, to also include outlet level monitoring. GU2 PDUs configured with active outlet relays can remotely control distribution of AC power (On/Off/Reboot) to individual outlets. Outlet switching is user controlled via web GUI, SNMP, JSON API or external management software. LED status indicators, located adjacent to each outlet, provide visual power status indication for each outlet. Green = Outlet power On Red = Outlet power Off Amber = Error Condition Off = No power to PDU outlet circuit Outlet switching is achieved using bi-stable magnetic latching relays, which reduce overall power consumption as the relay coils are not energized unless being switched on/off. GU2 PDUs include support for user configurable per outlet power-on sequencing. In the event of a power failure, the PDU can be user configured to return all relays to the open position, no power to outlets. When power is restored, PDU outlet power-on sequencing reduces the potential of breakers or fuses from opening due to high in-rush currents. Geist Rev 02/2018 3
4 1.5 SAFETY AND REGULATORY COMPLIANCE GU2 PDUs are tested in accordance with the harmonized EN/UL/CSA safety standards and marked UL or CE compliant as appropriate. They are evaluated for safe operation under normal and fault conditions to verify that faulty product, incorrect use or exposure to disruptive environmental influences do not result in unexpected hazardous conditions. Where applicable, compliance to declared regional or national differences are also evaluated. Geist products are regulated for safety, emissions, and environment impact per the below agency guidelines: Underwriters Laboratories (UL) UL Standards are used to assess products; test components, materials, systems and performance; and evaluate environmentally sustainable products, renewable energies, food and water products, recycling systems and other innovative technologies. The UL standards specific to this equipment are listed in the UL Online Certification Library under the file number noted on the device name plate. CE The placement of the CE mark on a product signifies a manufacturer's declaration that the product complies with the applicable European (EU) health, safety, and environmental protection requirements, including EU legislation and product directives. The CE mark is required for products offered for sale within the European Economic Area (EEA). The specific regulations, directives, and standards applicable to each product are specified on the Declaration of Conformity. Federal Communications Commission (FCC) The Federal Communications Commission (FCC) regulates interstate and international communications by radio, television, wire, satellite, and cable in all 50 states, the District of Columbia and U.S. territories. An independent U.S. government agency overseen by Congress, the commission is the United States' primary authority for communications laws, regulation and technological innovation. The FCC standards specific to this equipment are: This Class A device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference (2) This device must accept any interference received, including interference that may cause undesired operation. This Class A digital apparatus complies with Canadian ICES-003. RoHS/WEEE WEEE stands for Waste from Electrical and Electronic Equipment. WEEE Directive 2002/96/EC mandates the treatment, recovery and recycling of electric and electronic equipment (90% ends up in landfills). All applicable products in the EU market must pass WEEE compliance and carry the "Wheelie Bin" sticker. RoHS, also known as Lead-Free, stands for Restriction of Hazardous Substances. RoHS, also known as Directive 2002/95/EC, originated in the European Union and restricts the use of six hazardous materials found in electrical and electronic products. All applicable products in the EU market after July 1, 2006 must pass RoHS compliance. RoHS impacts the entire electronics industry and many electrical products as well. 1.6 LISTING/CERTIFICATIONS The GU2 PDU operates within the guidelines of the specified agency standards and regional variants and does not adversely affect or compromise the safety compliance of other devices connected to the system. It is designed for commercial and light industrial use only in restricted access locations. Geist Rev 02/2018 4
5 1.7 SERVICEABILITY The following sections describe important serviceability conditions: The GU2 PDU provides hot-swappable field exchange or upgrade of the IMD without disconnection of the AC mains supply or device loads. 2.0 ENVIRONMENTAL CONDITIONS 2.1 AMBIENT TEMPERATURE Operating: UL: 50 F 140 F (10 C 60 C) CE: 50 F 122 F (10 C 50 C) Storage: -13 F 149 F (-25 C 65 C) Note: Maximum environmental operating temperature is 60 C (UL) and 50 C (CE) at full (100%) input and output nameplate rating, with per receptacle max loading at half (50%) of the outlet rating. 2.2 RELATIVE HUMIDITY Operating and Storage: 5 95% non-condensing 2.3 ELEVATION Operating: 0ft (0m) to 10,500ft (3,200m) Storage: 0 ft (0m) to 50,000ft (15,240m) 3.0 USER ACCESSORIES AND PACKAGING The specified system is supplied with a quick start guide. The guide includes installation instructions, a functional description of the equipment, safety precautions, illustrations, operating procedures and general maintenance guidelines. 4.0 WARRANTY The manufacturer warrants against defects in materials and workmanship for five (5) years; Three (3) years standard, with two (2) additional years after product registration. 5.0 QUALITY ASSURANCE 5.1 MANUFACTURER QUALIFICATIONS Geist, a division of Vertiv, provides more than thirty years experience in the design, manufacture and testing of systems and the company is certified to ISO 9001 (2015). 5.2 FACTORY TESTING Each PDU is run through an End-of-Line electrical and mechanical factory test to ensure compliance with the product specification. Geist Rev 02/2018 5
Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL 1.1 SUMMARY
1.1 SUMMARY Liebert MPX Rack Power Distribution Unit (PDU) Guide Specifications 1.0 GENERAL This specification defines the electrical and mechanical characteristics and requirements for a continuous-duty,
More informationCS-10H0A413H3 (Master) Key Features. CL-10H0A413H3 (Link)
CS-10H0A413H3 (Master) CL-10H0A413H3 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationCS-12HDE444C8 (Master) Key Features. CL-12HDE444C8 (Link)
CS-12HDE444C8 (Master) CL-12HDE444C8 (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationSwitched, Outlet Level Monitoring
Part Number Power Configuration Physical Configuration RCURN082-102D20TL5-OD Switched, Outlet Level Monitoring 20A, 120V, 1.9kW 19in / 483mm Horizontal Description The RCURN082-102D20TL5-OD provides hands-on
More informationG GRCOW PH6PS6-D-IP44 Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration G1306 -- GRCOW246-103PH6PS6-D-IP44 Power Monitoring, Outlet Level 32A,, 7.3kW 72 in / 1829 mm Vertical Description G1306 -- GRCOW246-103PH6PS6-D-IP44
More information25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC A Red 415V, 0U, TAA
25.2kW 3-Phase Switched PDU, LX Platform Interface, 240V Outlets (24 C13/6 C19), Touchscreen LCD, IEC 309 60A Red 415V, 0U, TAA MODEL NUMBER: PDU3XEVSR6G60B Highlights 25.2kW 240V 3-phase switched 1.8m
More informationCS-24VD-L30MA (Master) Key Features. CL-24VD-L30MA (Link)
CS-24VD-L30MA (Master) CL-24VD-L30MA (Link) The Server Technology Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while
More informationAuto-Transfer Rack Power Distribution Unit
Auto-Transfer Rack Power Distribution Unit geistglobal.com 2 Auto-Transfer Rack Power Distribution Unit Table of Contents Part I Specifications 3 1 Overview... 3 2 Environmental... 3 Tem perature... 3
More informationipdu Pocket Guide NORTH AMERICA
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide NORTH AMERICA Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More informationIntelligent PDUs. Best in Class Outlet Density Optimal Form Factors Superior Reliability
TM Intelligent PDUs Best in Class Outlet Density Optimal Form Factors Superior Reliability SmartZone G5 Value Proposition Quality & Reliability High Temp High Power Density Hot-Swappable and Upgradable
More informationipdu Pocket Guide INTERNATIONAL
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide INTERNATIONAL Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More information5.8kW Single-Phase Switched PDU, 208/240V Outlets (8 C13 & 6 C19), L6-30P, 15ft Cord, 2U Rack-Mount, TAA
Management Interface The management interface for this PDU model is transitioning to a new technology platform. The new interface can be distinguished by a USB-A port (for EnviroSense2 modules) in place
More informationInstruction Manual Basic Rack PDU VP7541 and VP9571A
Instruction Manual Basic Rack PDU VP7541 and VP9571A VertivCo.com/geist Table of Contents Specifications... 3 Overview... 3 Environmental... 3 Temperature... 3 Humidity... 3 Elevation... 3 Electrical...
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationThe -3Ph extension on a product indicates a 3 Phase power product.
Power Terms Glossary 20-Amp Power Input Support: 20-amp Power Input Support. IEC320/C20 power inlet receptacles supports any power cord with IEC320/C19 power connector (PTCORD-XX). 24-Character Outlet
More informationUSB 2.0 RG2324/ Port USB 2.0 Fiber Optic Extender System. User Guide
USB 2.0 RG2324/2344 4-Port USB 2.0 Fiber Optic Extender System User Guide Thank you for purchasing the USB 2.0 RG2324 or RG2344. This document applies to the following part numbers: Please read this guide
More informationC2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) Key Features
C2W36CE-DQME2M99 (Master) C2X36CE-DQME2M99 (Expansion) The Server Technology PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine
More informationOPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES
OPERATING MANUAL AC POWER DISTRIBUTION UNITS VIGILANT SERIES www.unipowerco.com Manual No. PDUAC1USM-2 pduac1us-man-rev2-0115.indd 2015 UNIPOWER LLC All Rights Reserved NORTH AMERICA 3900 Coral Ridge Drive,
More informationRCOBN PH6TL21-D Power Monitoring, Outlet Level. Part Number
Part Number Power Configuration Physical Configuration RCOBN248-102PH6TL21-D Power Monitoring, Outlet Level 20A, 120/208V WYE, 5.7kW 66 in Vertical Description RCOBN248-102PH6TL21-D provides site managers
More informationUSB 3 Extenders. 4-Port Point-to-Point Extender System User Guide
USB 3 Extenders 4-Port Point-to-Point Extender System User Guide Document 411-0024-30 Rev A June 2018 Contents Introduction...3 Features...3 Unpacking...3 A Quick Look at the USB 3 Extenders...4 The Local
More informationMetered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U,12.5kW,208V,(30)C13, (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: Hubbell CS8365C, Cord Length: 10 feet ( 3.05 meters ), Output:
More informationInstruction Manual. Rack PDU XP Series. geistglobal.com
Instruction Manual Rack PDU XP Series geistglobal.com Table Of Contents 3 Table of Contents Specifications 4 Overview... 4 Environmental... 4 Tem perature... 4 Hum idity... 4 Elevation... 4 Electrical...
More informationPolar PDUs POWER MANAGEMENT
Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R
Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:
More informationFrequently Asked Questions
Q. What is the power metering accuracy on CPI econnect PDUs? A. The power metering accuracy on CPI econnect PDUs is ±1% for each breaker. Meters are included in Monitored, Monitored, Switched and Switched
More informationPE A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU. 8 outlets. 20A (UL derated 16A) / 16A. Outlet Power Measurement
PE8208 20A/16A 8-Outlet 1U Outlet-Metered & Switched eco PDU 8 outlets 20A (UL derated 16A) / 16A Outlet Power Measurement The PE8208 eco PDU is intelligent PDUs that contains 8 AC outlets and is available
More informationUSB Raven Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3104 4-Port USB 3.1, 100m CAT 6a/7 Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3104. Please read this guide thoroughly. This document applies
More information8-Outlet eco PDU PE6208AV
8-Outlet eco PDU Ideal for CI and Pro-AV applications, the ATEN NRGence eco PDU is an intelligent 1U rack PDU that contains 8 AC outlets available in an IEC socket configuration. The unique design with
More informationUSB Raven Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide
USB 3-2-1 Raven 3124 4-Port USB 3.1, 200m Multimode Fiber Point-to-Point Extender System User Guide Thank you for purchasing the USB 3-2-1 Raven 3124. Please read this guide thoroughly. This document applies
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord
Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,
More informationUPS Series. features: uninterruptible power supply. what great systems are built on.
uninterruptible power supply uninterruptible power supply with energy saver design that is optimized to address the needs of A/V systems features: Pure Sine Wave technology with Automatic Voltage Regulation
More informationQuickSpecs. HPE Metered and Switched Power Distribution Units (PDU) Overview
HPE Metered and Switched Power Distribution Units (PDU) Overview Looking for a power distribution unit that meets the demands of high temperature operating environments and provides monitoring and switching
More informationPDU Inspired by Your Data Center. W IEC PDU Series
PDU Inspired by Your Data Center W IEC PDU Series Intelligent kwh PDU - W series Power Efficiency Management With today s increasing demand for high technology power management solutions, PDU kwh measurement
More informationPE8216/PE8324. Energy Intelligence Solutions
PE8216/PE8324 As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (eco PDUs) to effectively increase the efficiency of data center power usage. The
More informationQuickSpecs. HP Remote Monitoring Power Distribution Units. Overview
QuickSpecs Overview (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are excellent choices for data centers wanting to make the most of circuit capacity
More informationSwitched Rack Power Distribution Unit
Switched Rack Power Distribution Unit AS-216-520-30A-L530 Installation and Quick Start Contents Product Description and Inventory...................... 1 AS-216-520-30A-L530....................... 1 Additional
More informationUSER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH
USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before
More informationInstruction Manual. Rack PDU BRE and VRTE Series. geistglobal.com
Instruction Manual Rack PDU BRE and VRTE Series geistglobal.com Table Of Contents 3 Table of Contents Introduction 4 Welcome... 4 About this Manual 7 Revision... History 7 Organization... of the Manual
More informationECO PDU Power Distribution Unit
ECO PDU Distribution Unit PE6108/PE6208/PE8108/PE8208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationNI Serial Hardware Specifications Guide
NI Serial Hardware Specifications Guide Contents This document lists safety and compliance information for NI Serial hardware, as well as physical specifications, software characteristics, and recommended
More informationSECTION ( ) LIGHTING CONTROL PANELBOARD
(26 24 16.02) LIGHTING CONTROL PANELBOARD PART 1 GENERAL 1.01 SCOPE A. The Contractor shall furnish and install Lighting Control Panelboards as specified and as shown on the contract drawings. B. The Lighting
More informationVERTIV INTELLIGENT RACK PDU
VERTIV INTELLIGENT RACK PDU VP8941, VP8641, VP5870V, VP5665V, VP8965, VP8932, VP8930, VP4551V and VP8959NA3 VertivCo.com/geist VERTIV INTELLIGENT RACK PDU Page 2 CONTENTS 1. Introduction... 6 1.1. Welcome...
More informationipdu Pocket Guide INTERNATIONAL
Best in Class Outlet Density Optimal Form Factors Superior Reliability TM ipdu Pocket Guide INTERNATIONAL Welcome to the Panduit G5 Series of PDU s and Accessories Quality & Reliability 3-Year standard
More informationModels. Specifications
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors
More informationIKS-G6524A/G6824A Series Quick Installation Guide
IKS-G6524A/G6824A Series Quick Installation Guide Edition 3.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax:
More informationPriva Blue ID Analogue output module with manual override AO2m/AO4m
Priva Blue ID Analogue output module with manual override Short circuit proof and self-restoring The module's analog outputs are self-restoring after a brief short-circuit or overload. After a brief short-circuit
More informationPriva Blue ID Relay output module DOR4/DOR8
Priva Blue ID Relay output module Modular design Module and base form a unique combination. As a result of this, a module cannot be incorrectly positioned in a base. You simply click the base with module
More informationSmartOnline V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch
SmartOnline 200-240V 6kVA 5.4kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, USB, DB9 Serial, Bypass Switch MODEL NUMBER: SU6000RT4UHVG Highlights 6kVA / 6000VA / 5400W on-line
More informationPowerstar PS3204rm2u True online 2KVA /1800W (19.7 deep)
Powerstar PS3204rm2u PS3204 tower (120V) 3.4 H x16.9 W x19.7 D 85 x 430 x 497mm Model upgrade from PS3200 (GXT2) and PS3203 (GXT3)- now using Liebert GXT4 electronics Double Conversion true online type
More informationCAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. Available in Basic, Metered, and Smart PDU models.
CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. TM Introducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors of
More informationGeist Upgradeable with IMD-03x Instruction Manual
Geist Upgradeable with IMD-03x Instruction Manual geistglobal.com 2 Geist Upgradeable with IMD-03x Instruction Manual Table of Contents Introduction 5 Welcome... 5 About this Manual 8 Revision... History
More informationInstruction Manual Rack In-Line Power Measurement Unit. L Series
Instruction Manual Rack In-Line Power Measurement Unit L Series Geist Manufacturing 1821 Yolande Ave., Lincoln, NE 68521 800.432.3219 402.474.3400 F: 402.474.4369 www.geistmfg.com Contents Specifications...3
More informationMODEL NUMBER: B IP2
Free NetCommander-AXS Management Software is available for access and control of all of your Tripp Lite NetCommander IP KVM switches (B070 and B072 series). From a single interface, you can access server
More informationUSB 3.0 SP Port USB m Multimode Fiber Extender System. User Guide
USB 3.0 SP3022 2-Port USB 3.0 100m Multimode Fiber Extender System User Guide Thank you for purchasing the USB 3.0 SP3022. Please read this guide thoroughly. This document applies to Part Numbers: 01-00426,
More informationSecurity Expert Smartcard Reader Mini
[ MINI ] Security Expert 1 Security Expert Smartcard Reader Mini The Security Expert Smartcard Reader provides a complete multi-technology smart card RFID solution. Compatible with all Wiegand data capable
More informationMultiport Analog VoIP Router
JUNE 2007 VOE231 VOE232 VOE233 VOE234 VOE235 VOE236 Multiport Analog VoIP Router Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved
More informationSmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9
SmartOnline 120V 3kVA 2.7kW Double- Conversion UPS, 3U Rack/Tower, Extended Run, WEBCARDLX Network Interface, LCD, USB, DB9 MODEL NUMBER: SU3000RTXLCD3N Highlights Zero transfer time suitable for advanced
More informationUSB 3.1 CAT6A/7 EXTENDER
USER MANUAL ICU504A USB 3.1 CAT6A/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM Power Mode Config Status Link Video USB 2 USB 3 Power Mode Config Status Link Video USB 2 USB 3 TABLE OF CONTENTS PRODUCT OPERATION
More informationGeist EMEA. Geist USA. Geist APAC
Product Overview Headquartered in Lincoln, Nebraska, Geist designs and manufactures industryleading technology and software to power, cool, monitor and manage critical data center infrastructure. We produce
More informationNVT Phybridge, Inc Superior Court, Unit 3 Oakville, ON, L6L 0C4 Phone: Web:
NVT Phybridge enables our customers to transform their existing infrastructure and migrate to IP with confidence. NVT Phybridge products offer technologically advanced features including power over long
More informationSmartOnline 120V 2.2kVA 1.8kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, WEBCARDLX Network Interface, ENERGY STAR
SmartOnline 120V 2.2kVA 1.8kW Double- Conversion UPS, 2U Rack/Tower, Extended Run, WEBCARDLX Network Interface, ENERGY STAR MODEL NUMBER: SU2200RTXLCDN Highlights Zero transfer time suitable for advanced
More informationECO PDU PE7108/PE7208
PE7108/PE7208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The PE7108 / PE7208 eco PDUs are intelligent
More information[SmartX Controller ] Introduction. Features. SmartStruxure solution
1 AS-P I/O, alarms, and users, handle scheduling and logging, and communicate using a variety of protocols. Because of this, most parts of the system function autonomously and continue to run as a whole
More informationPN5212/PN5320/PN7212/PN7320
PN522/PN520/PN722/PN720 Power Over the NET Power Distribution Units ALTUSEN Power Over the NET products are Power Distribution Units that offer outlet level control combined with remote access to give
More informationBack-UPS RS APC Back-UPS RS 800VA 120V Black
Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email
More informationPriva Blue ID Digital input module DI4/DI8/DI16
Priva Blue ID Digital input module Modular design An Priva Blue ID DI4 Digital input module, Priva Blue ID DI8 Digital input module or Priva Blue ID DI16 Digital input module are used to take status and
More informationGeist Upgradeable 2.0 Instruction Manual
Geist Upgradeable 2.0 Instruction Manual geistglobal.com 2 Geist Upgradeable 2.0 Manual Table of Contents Introduction 5 Welcome... 5 About this Manual 7 Revision... History 8 Organization... of the Manual
More informationVERTIV INTELLIGENT RACK PDU
VERTIV INTELLIGENT RACK PDU VP8841, VP8867, VP8865, VP8866, VP7811B, VP8868, VP8832 and VP8830 VertivCo.com/geist Vertiv Intelligent Rack PDU Page 2 CONTENTS 1. Introduction... 6 1.1. Welcome... 6 2. About
More informationSmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules
SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules MODEL NUMBER: SV40KM2P2B Highlights Scalable capacity up to
More informationBasic PDU Modules SW Meter PDU SW Meter Switch PDU SW Three Phase PDU. How to install 11-12
01-02 Basic PDU 03-04 Modules 05-06 SW Meter PDU 07-08 SW Meter Switch PDU 09-10 SW Three Phase PDU 11-12 How to install Safewell Basic PDU Series Model:SW-1U-8IEC13-K Product Description Size 19 * 1U
More informationNI PXI-1042 Series Power Supply Shuttle
USER GUIDE NI PXI-1042 Series Power Supply Shuttle Introduction Unpacking The NI PXI-1042 Series power supply shuttle is a replacement part for the NI PXI-1042 Series chassis. To minimize downtime caused
More informationPDU - Overview / Non-Intelligent PDU s
PDU - Overview / Non-Intelligent PDU s InfraPower Rack Power Distribution Units InfraPower Rack PDU Range Switched (Outlet kwh PDU) Monitored (kwh PDU) Metered Basic WSi WS W MD Basic Outlet Measurement
More informationMODEL NUMBER: B IP2-K
Free NetCommander-AXS Management Software is available for access and control of all of your Tripp Lite NetCommander IP KVM switches (B070 and B072 series). From a single interface, you can access server
More informationECO PDU PE5108/PE5208
1 NRGence Energy Intelligence Solutions PE5108/PE5208 ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage.
More informationInstruction Manual. Rack PDU BR, SP, SVR, VRT, NSV, and VSS Series. geistglobal.com
Instruction Manual Rack PDU BR, SP, SVR, VRT, NSV, and VSS Series geistglobal.com Table Of Contents 3 Table of Contents Introduction 5 Welcome... 5 About this Manual 8 Revision... History 8 Organization...
More informationInnovative. Engineering. Power. structure source. Making the complex, simple. Structure Source PDU s
Structure Source PDU s Innovative Power Engineering High Quality Power Distribution for the Data Centre structure source Making the complex, simple structure source product range Rack and Server Power
More informationVERTIV RACK PDUS. Power Perfectly Configured for Your IT Application
VERTIV RACK PDUS Power Perfectly Configured for Your IT Application VERTIV RACK PDUS Enhanced Performance and Management of Dynamic IT Spaces Enhance Business Agility, Efficiency and Availability with
More informationPower Distribution Units for Data Centers
BRC_PowerMax_INT_Draft_I.qxp_Layout 1 9/11/17 2:00 PM Page 2 Power Distribution Units for Data Centers WWW.SIEMON.COM PowerMax Power Distribution Units 2 Siemon s PowerMax line of PDUs range from basic
More informationMetered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13
Metered Rack PDU Rack PDU, Metered, Zero U, 10A, 230V, (16) C13 APC Metered Rack PDU, Input: 230V, Input Connections: IEC-320 C14, Cord Length: 10 feet ( 3.05 meters ), Output: 230V, Output Connections:
More informationOptical DVI Daisy-chain Extender
Manual Contents Manual Contents 1-0 Welcome!, Product Description 1-1 System Requirements for Setup 1-2 Installation 1-3 Troubleshooting, Maintenance, Technical Support 1-5 Product Specifications 1-6 Warranty
More informationSpotlight Versatile Connectivity Provides 16-port 10/100BASE-TX plus 2-port Gigabit-SX/LX/BX combo
Series Hardened Managed 16-port 10/100BASE with 2-port Gigabit combo Ethernet Switch NEMA TS2 UL61010 ISA.12.12.01 Overview EtherWAN s Series provides a Hardened Fully Managed 18-port switching platform
More informationInstallation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A
Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights
More informationHardwired Uninterruptible Power Supply
96-01160 / rev. 1 / 08-15-11 Hardwired Uninterruptible Power Supply EXCEPTIONAL SUPPORT & PROTECTION Hardwired Uninterruptible Power Supply with Energy Saver design that is optimized to address the needs
More informationInstalling and Configuring Rialto Analytic Appliances
Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation
More informationTruVision IP Thermal Camera Installation Guide
TruVision IP Thermal Camera Installation Guide P/N 1073335-EN REV B ISS 19OCT17 Copyright Trademarks and patents Manufacturer Certification 2017 United Technologies Corporation, Interlogix is part of UTC
More informationUSB 2.0 CAT5E/6/7 EXTENDER
USER MANUAL IC402A-R2 USB 2.0 CAT5E/6/7 EXTENDER 24/7 AT OR VISIT BLACKBOX.COM + + + + Mode Config Power Link Host Activity Power Link Host Activity TABLE OF CONTENTS PRODUCT OPERATION AND STORAGE... 3
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationMODEL NUMBER: B IP4
Free NetCommander-AXS Management Software is available for access and control of all of your Tripp Lite NetCommander IP KVM switches (B070 and B072 series). From a single interface, you can access server
More informationSmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module
SmartOnline SV Series 20kVA Small-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, No SVBM Battery Module MODEL NUMBER: SV20KS1P0B Highlights Scalable capacity up
More informationPremium Online Series
Premium Online Series UPS backup power systems backup protection with double conversion that isolates and conditions output power for clean, consistent, reliable power features: Permanent connection to
More informationSmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets
SmartPro 120V 1.5kVA 1.35kW Line-Interactive Sine Wave UPS, 2U Rack/Tower, WEBCARDLX Network Interface, LCD, USB, 8 Outlets MODEL NUMBER: SMART1500RM2UN Highlights Corrects under- and overvoltages from
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationSmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide
SmartNode 4830 DSL Series Analog VoIP Integrated Access Device Quick Start Guide Approval Models that are equipped with telecom interfaces have been approved for connection to the public telecommunication
More informationECO PDU. Features. PE5220sA
ECO PDU PE5220s As part of its NRGence line, ATEN has developed a new generation of green energy power distribution units (PDUs) to effectively increase the efficiency of data center power usage. The NRGence
More informationPriva Blue ID Communication module RS485 SC44
Priva Blue ID Communication module RS485 Modular design An Priva Blue ID Communication module RS485 provides the system with two RS485 ports for serial communication and is used to connect field bus devices.
More informationPDI Modular Compact Remote Power Panel
Guide Specifications (Revision 000, 6/17/2016) 1 GENERAL 1.1 Summary These specifications describe requirements for a remote power panel (RPP) distributing power to sensitive loads. These specifications
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationLVN5200A-R2, rev. 1, Hardware Installation Guide
LVN5200A-R2 LVN5250A-R2 LVN5200A-R2, rev. 1, Hardware Installation Guide Customer Support Information Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support
More informationNI 6521 Specifications
NI 6521 Specifications This document lists specifications for the NI 6521 device. All specifications are subject to change without notice. These specifications are typical at 25 C unless otherwise noted.
More information8 channel universal input and 4 channel Form C digital output
1 I/O Modules UI-8/DO-FC-4 and UI-8/DO-FC-4-H 8 channel universal input and 4 channel Form C digital output Introduction The UI-8/DO-FC-4 and UI-8/DO-FC-4-H are universal input, 8 channel and digital output,
More information