PROVEN QUALITY, LEADING TECHNOLOGY.

Size: px
Start display at page:

Download "PROVEN QUALITY, LEADING TECHNOLOGY."

Transcription

1 Heat Systems PR70 2 Component Liquid Dispensing Systems A PR70 HEAT MANUAL For use in dispensing of sealants and adhesives Important Safety Instructions Read all warnings and instructions in this manual. This manual is supplemental and only covers some very specific warnings and instructions as they pertain to the heat systems. Please refer to manual A for a complete list of warnings, wetted materials, warranty information and instructions for the entire machine. PROVEN QUALITY, LEADING TECHNOLOGY. GRACO OHIO INC PORT JACKSON AVE. NW NORTH CANTON, OH Phone: Fax: LiquidControlService@graco.com LiquidControlParts@graco.com Copyright 2007, Graco Inc is a registered to I.S. EN ISO 9001

2 Table of Contents Table of Contents Table of Contents... 2 Supplied Manuals... 3 Related Manuals... 3 Warnings... 4 Heat Controller Diagram... 5 Configurations... 6 Keys and Displays Error Code Getting Started Home Page Changing Temperature Display Units Resetting the Controller Setup Page Setup Page Analog Input Menu...17 *Setup Page Limit Menu...17 Setup Page Loop Menu...18 Setup Page Output Menu...18 Setup Page Alarm Menu...19 Setup Page Global Menu...19 Operations Page Operations Page Analog Input Menu...19 * Operations Page Limit Menu...20 Operations Page Monitor Menu...20 * Operations Page Alarm Menu...20 Operations Page Loop Menu...20 Technical Data Dimensions Wiring Diagrams A 2 of 43

3 Manuals Supplied Manuals The following manuals will be supplied with the PR70. PR70 Operation Refer to these documents for detailed machine Part Description information Manual, Operation & Maintenance PR70 PR70 Feed System Part Description Manual, Tank/Feed System, PR70 Dispense Valve, MD2 Part Description Manual, Dispense Valve, MD2 * Heat Control Module(s) Part Description Manual, Heat Control, Tank/Hoses Related Manuals The following manuals are for accessories to be used PR70 Operation with the PR70 machine. Part Description Manual, Operation & Maintenance PR70 PR70 Feed System Part Description Manual, Tank/Feed System, PR70 Dispense Valve, MD2 Part Description Manual, Dispense Valve, MD2 Heat Control Module(s) Part Description Manual, Heat Control, Tank/Hoses * The Heat Control Module manual is not provided for machines that do not have a Heated Tank and/or Hose component A 3 of 43

4 Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable. WARNING ELECTRIC SHOCK HAZARD Improper grounding, setup, or usage of the system can cause electric shock. Turn off and disconnect power cord before servicing equipment. Use only grounded electrical outlets. Use only 3-wire extension cords. Ensure ground prongs are intact on sprayer and extension cords. Do not expose to rain. Store indoors. EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. Do not operate the unit when fatigued or under the influence of drugs or alcohol. Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer s warnings. For complete information about your material, request MSDS forms from distributor or retailer. Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer s replacement parts only. Do not alter or modify equipment. Use equipment only for its intended purpose. Call your distributor for information. Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not kink or over bend hoses or use hoses to pull equipment. Keep children and animals away from work area. Comply with all applicable safety regulations A 4 of 43

5 Diagram Heat Controller Diagram Figure 1: Heat Package Control Box Key: 1. Main Power Disconnect 4. Heat Controller 3 2. Heat Controller 1 5. Heat Controller 4 3. Heat Controller 2 Note: Depending on which setup is ordered, the configuration shown in Figure 1 will change. There could be anywhere from 1-4 heat controllers and the controllers could be integrated or non-integrated. Please refer to the matrices on the following page for further detail and explanations A 5 of 43

6 Configurations Configurations It is very important that you correctly identify which controllers are running single and double probes. In the event that you need to enter the SETUP PAGES of their respective controllers, there are slight differences that will be covered later in the manual Wiring Diagrams are included later in the manual 1 2 Front Back Figure 2: LC0066 (1 Blanket and 2 Probes) No. Part Number/Label Description Single Load, Dual Probe Controller 2. 81/2063/11 Operator, Sel, 2P - PG-1 Heat Blanket Connector - PG-1B Blanket Thermocouple Connector - PG-1M Material Thermocouple Connector 1 2 Front Figure 3: LC0067 (1 Blanket and 1 Probe) No. Part Number/Label Description Single Load, Single Probe Controller 2. 81/2063/11 Operator, Sel, 2P - PG-1 Heat Blanket Connector - PG-1B Blanket Thermocouple Connector Back A 6 of 43

7 Configurations 1 2 Front Back Figure 4: LC0068 (2 Blankets and 4 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Dual Probe Controller - PG-1M Material Thermocouple Connector 2. 81/2063/11 Operator, Sel, 2P - PG-2 Heat Blanket Connector - PG-1 Heat Blanket Connector - PG-2B Blanket Thermocouple Connector - PG-1B Blanket Thermocouple Connector - PG-2M Material Thermocouple Connector 1 2 Front Back Figure 5: LC0069 (2 Blankets and 2 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Single Probe Controller - PG-1B Blanket Thermocouple Connector 2. 81/2063/11 Operator, Sel, 2P - PG-2 Heat Blanket Connector - PG-1 Heat Blanket Connector - PG-2B Blanket Thermocouple Connector A 7 of 43

8 Configurations Front Back Figure 6: LC0070 (2 Blankets and 3 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Double Probe Controller - PG-1B Blanket Thermocouple Connector Single Load, Single Probe Controller - PG-1M Material Thermocouple Connector 3. 81/2063/11 Operator, Sel, 2P - PG-2 Heat Blanket Connector - PG-1 Heat Blanket Connector PG-2B Blanket Thermocouple Connector Front Back Figure 7: LC0071 (3 Blankets and 5 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Double Probe Controller - PG-2 Heat Blanket Connector Single Load, Single Probe Controller - PG-2B Blanket Thermocouple Connector 3. 81/2063/11 Operator, Sel, 2P - PG-2M Material Thermocouple Connector - PG-1 Heat Blanket Connector - PG-3 Heat Blanket Connector - PG-1B Blanket Thermocouple Connector - PG-1B Blanket Thermocouple Connector - PG-1M Material Thermocouple Connector A 8 of 43

9 Configurations Front Back Figure 8: LC0072 (3 Blankets and 4 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Double Probe Controller - PG-1M Material Thermocouple Connector Single Load, Single Probe Controller - PG-2 Heat Blanket Connector 3. 81/2063/11 Operator, Sel, 2P - PG-2B Blanket Thermocouple Connector - PG-1 Heat Blanket Connector - PG-3 Heat Blanket Connector - PG-1B Blanket Thermocouple Connector - PG-3B Blanket Thermocouple Connector 1 2 Front Back Figure 9: LC0073 (3 Blankets and 3 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Single Probe Controller - PG-2 Heat Blanket Connector 2. 81/2063/11 Operator, Sel, 2P - PG-2B Blanket Thermocouple Connector - PG-1 Heat Blanket Connector - PG-3 Heat Blanket Connector - PG-1B Blanket Thermocouple Connector - PG-3B Blanket Thermocouple Connector A 9 of 43

10 Configurations Front Back Figure 10: LC0074 (4 Blankets and 6 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Double Probe Controller - PG-2 Heat Blanket Connector Single Load, Single Probe Controller - PG-2B Blanket Thermocouple Connector 3. 81/2063/11 Operator, Sel, 2P - PG-3 Heat Blanket Connector - PG-1 Heat Blanket Connector - PG-3B Blanket Thermocouple Connector - PG-1B Blanket Thermocouple Connector - PG-4 Heat Blanket Connector - PG-1M Material Thermocouple Connector - PG-4B Blanket Thermocouple Connector Front Back Figure 11: LC0075 (4 Blankets and 5 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Double Probe Controller - PG-2B Blanket Thermocouple Connector Single Load, Single Probe Controller - PG-2M Material Thermocouple Connector 3. 81/2063/11 Operator, Sel, 2P - PG-3 Heat Blanket Connector - PG-1 Heat Blanket Connector - PG-3B Blanket Thermocouple Connector - PG-1B Blanket Thermocouple Connector - PG-4 Heat Blanket Connector - PG-1M Material Thermocouple Connector - PG-4B Blanket Thermocouple Connector - PG-2 Heat Blanket Connector A 10 of 43

11 Configurations 1 2 Figure 12: LC0075 (4 Blankets and 4 Probes) No. Part Number/Label Description No. Part Number/Label Description Single Load, Single Probe Controller - PG-2B Blanket Thermocouple Connector 2. 81/2063/11 Operator, Sel, 2P - PG-3 Heat Blanket Connector - PG-1 Heat Blanket Connector - PG-3B Blanket Thermocouple Connector - PG-1B Blanket Thermocouple Connector - PG-4 Heat Blanket Connector - PG-2 Heat Blanket Connector - PG-4B Blanket Thermocouple Connector A 11 of 43

12 Setup Keys and Displays The only controller programming and commands that are covered in this manual are what has been deemed necessary to run the heat package associated with the purchased machine. For more information on the controllers, please refer to the original manufactures website at Upper Display: In the Home Page, displays the process value, otherwise displays the value of the parameter in the lower display Zone Display: Indicates this controller s Standard Bus address in hexadecimal (1, 2, 3, 4, 5, 6, 7, 8, A, b, c, d, E, F, H) Lower Display: Indicates the set point or output power value during operation, or the parameters whose value appears in the upper display EZ Key: This key can be programmed to do various tasks, such as starting a profile Figure 13: Keys and Displays Infinity Key: Press to back up one level or press and hold for two (2) seconds to return to the home page Advance Key: Advances through parameter prompts Temperature Units Indicator Lights: Indicates whether the temperature is displayed in Fahrenheit or Celsius Output Activity: Number lights indicate activity of outputs 1-5 Percent Units Indicator: Lights when the controller is displaying values as a percentage or when the open loop set point is displayed Profile Activity: Lights when a profile is running. Flashes when a profile is paused Communications Activity Flashes when another device is communicating with this controller Up and Down Keys: In the home page, adjusts the set point in the lower display. In other pages, changes the upper display to a higher or lower value or changes a parameter Error Code The controller has been programmed so that the only error code that should appear is a message warning that the temperature of the blanket has exceeded fail safe temperature setting which will be indicated by the toggling between the normal settings and letters [Li.h2] in the Upper Display and [Attn] in the lower display and a If the message appears, shut down the heating element, allow the unit to cool and begin investigation as to the cause. Once the condition has been fixed, the message can be cleared by pressing the ADVANCE KEY and then using the UP and DOWN ARROW KEYS to find the CLEAR COMMAND [ CLr]. Press the ADVANCE KEY one more time to clear the message A 12 of 43

13 Getting Started Once the heat controllers have been turned on, the machine and its contents will get hot. Use caution when working with the machine Read all manufacturer s warning and material MSDS to know the specific hazards of the material used. Wear respirator, gloves and other protective clothing as necessary before dispensing material. Figure 14: Turning on the Heater Control Module 1. The machine should arrive fully assembled, programmed and ready to go. After filling the tanks with material, activate any of the necessary heat controllers by turning the selector switch to the ON Position 2. The Controller will already be in the HOME PAGE which displays the ACTIVE PROCESS VALUE (The current temperature of active probe) on top and the ACTIVE SET POINT (The desired material temperature) on the bottom. To adjust the set point, simply press the UP or DOWN ARROWS to the desired temperature Figure 15: Home Page 3. Other values can be seen while in the home page by pressing the ADVANCE KEY and the INFINITY KEY to move back and forth THE UNITS ALL COME PRE-PROGRAMMED FROM THE FACTORY AND IT IS NOT RECOMMENDED THAT YOU CHANGE ANY PARAMETERS FROM THE HOME PAGE MENU EXCEPT FOR YOUR TEMPERATURE SET POINTS A 13 of 43

14 4. To get to any of the pages needed for programming or adjustments, you must first return to the HOME PAGE. To return to the home page from anywhere, press and hold the infinity key for two (2) seconds Figure 14: Getting to the HOME SCREEN 5. To get from the HOME PAGE to the OPERATIONS PAGE, hold down BOTH ARROW KEYS for THREE (3) SECONDS. The Operations page should look similar to the image below Figure 15: Getting to the Operations Page 6. To get from the HOME PAGE to the SETUP PAGE, hold down BOTH ARROW KEYS for SIX (6) SECONDS. The Setup page should look similar to the image below Figure 16: Getting to the Setup Page A 14 of 43

15 Home Page The Home page can be set to view up to 20 different parameters. However, as the default setting that leaves Graco s factory a user can: - Single Probe Units: Monitor the Blanket Temperature - Dual Probe Units: View the Active Process Value (Current Material Temperature) in the Upper Display and the Current Set Point (Desired Material Temperature) in the Lower Display. Adjust the Set Point by pressing the UP and DOWN ARROW Keys Monitor the blanket temperature by pressing the ADVANCE KEY or the INFINITY KEY Changing Temperature Display Units The Default factory setting on the controllers is Fahrenheit. To Change the units to Celsius: 1. Hold down BOTH ARROW KEYS for SIX SECONDS to get to the SETUP MENU (See figure 16 to verify) 2. Press the UP ARROW TWICE to get to the GLOBAL SUB-MENU (will appear in the upper display as [glbl]) 3. Press the ADVANCE KEY ONCE to get to the Temperature Units Screen 4. Press the UP ARROW ONCE to change from Fahrenheit to Celsius 5. Press the INFINITY KEY TWICE to return to the Home Screen A 15 of 43

16 Resetting the Controller If, for some reason, something on the controller has been changed and the problem cannot be easily rectified, the Graco Factory Pre-sets can be reset as can Watlow s. 1. To reset, make sure the Home Screen is what is showing and hold down the INFINITY and the ADVANCE KEYS together for 6 seconds. The Factory Page will then appear. Figure 17: Getting to the Factory Pages 2. Press the UP ARROW KEY until the Upper Display reads [diag] for the Diagnostics Menu 3. Press the ADVANCE KEY until the Lower Display reads [USr.r] for User Restore Set. Press the UP ARROW KEY once so that the Upper Display reads [Set1] and then press the INFINITY KEY until you return to the Home Page. Your Graco Factory Settings have now been restored. 4. To reset to the Watlow factory settings, please refer to their website at for more information. All of the information provided from here to the end of the manual is for informational and repair purposes only. It is not recommended that any of these menus be entered into or any of the values changed A 16 of 43

17 Setup Page Certain selections made during the course of the setup process will eliminate the Digital Input/Output and CURRENT menus Setup Page Analog Input Menu Display Parameter Name Description Select [SEn] *Sensor Type (Input 1 and 2) [tc] for Thermocouple (Default) Set the analog sensor type to match the device wired to this input [Lin] *Linearization (Input 1 and 2) [J] for J (Default) Set the linearization to match the thermocouple wired to this input [FiL] *Filter Time (Input 1 and 2) [0.5] (Default) Filtering smoothes out the process signal to both the display and the input. Increase the time to increase the filtering [i.er] Error Latching (Input 1 and 2) [off] for Off (Default) Turn input error latching on or off. If latching is on errors must be cleared manually [dec] Decimal (Input 1 and 2) [ 0] Whole (Default) Set the precision of the displayed value [S.bA] **Sensor Backup Enable (Input 1) If the input 1 sensor fails, the controller will use the input 2 sensor [Off] (Default) * Only 1 Analog Input Available for the Single Probe Controllers ** Only Available on Dual Probe Controllers *Setup Page Limit Menu Display Parameter Name Description Select [L.Sd] Sides [high] for High Select which side or sides of the process value will be monitored [L.hy] Hysteresis [3.0] (Default) Set the hysteresis for the limit function. This determines how far into the safe range the process must move before the limit turns the output back on [L.it] Integrate In a limit state the controller will turn off the outputs, terminate an active profile and freeze PID and TRU- TUNE TM calculations [No] (Default) *There is no Limit Menu for Single Probe Controllers A 17 of 43

18 Setup Page Loop Menu Display Parameter Name Description Select [h.ag] Heat Algorithm [Pid] (Default) Set the heat control method [C.Ag] Cool Algorithm [off] for Off (Default) Set the cool control method [C.Cr] Cool Output Curve [off] for Off (Default) Select a special cool output curve to change the responsiveness of the system [t.tun] Tru-Tune+ TM [no] for No (Default) Enable or disable the Tru-Tune+ TM adaptive tuning feature [t.agr] Autotune Aggressiveness [Crit] for Critical (Default) Select the aggressiveness of the autotuning calculations [UFA] User Failure Action Select what the controller outputs will do when the user switches control to manual mode modules [FAiL] Input Error Failure Select what the controller outputs will do when an input error switches control to manual mode [ L.dE] Open Loop Detect Enable Turn on the open-loop detect feature to monitor a closedloop operation for the appropriate response [ rp] Ramp Action Select when the controller s set point will ramp to the defined set point [L.SP] [h.sp] [SP.Lo] [SP.Hi] Low Set Point Set the low end of the set point range High Set Point Set the high end of the set point range Set Point Low Limit Open Loop Set the minimum value of the open-loop set point range Set Point High Limit Open Loop Set the maximum value of the open-loop set point range [off] for Off (Default on Dual Probe Only) Must be changed on single probe [off] for Off (Default on Dual Probe Only) Must be changed on single probe modules [ no] for No (Default) [off] for Off (Default) [ 0] [ 160] (Fahrenheit) [71] (Celcius) [-100] (Default - Fahrenheit) [ 100] (Default) Setup Page Output Menu Display Parameter Name Description Select [ o.fn] *Function (Output 1 and 3) Select what function will drive this output [heat] for Heat (output 1) [heat] for Heat (output 2 on single controllers only) [ o.ct] *Control (Output 1 to 4) Set the output control type. This parameter is used only by the PID control, but can be set anytime [ o.tb] *Time Base (Output 1 to 4) Set the time base for fixed-time-base control [ o.lo] *Low Power Scale (Output 1 to 4) The power output will never be less than the value specified and will represent the value at which output scaling begins [ o.hi] *High Power Scale (Output 1 to 4) The power output will never be greater than the value specified and will represent the value at which output scaling stops * Only one output available on Single Probe Controllers [ ALM] for Alarm (output 3) [ Ftb] for Fixed Time Base (Default) [1.0] for 1.0 seconds [ 0.0%] (Default) [100.0%] (Default) A 18 of 43

19 Setup Page Alarm Menu Display Parameter Name Description Select [ A.ty] Type (Alarm 1) [Pr.AL] for Process Alarm (Alarm #1) Select how the alarm will or will not track the set point [ A.Sr] Source [ Ai] Analog Input (Default) Select what will trigger this alarm [ A.iS] *Source Instance [ 2] (Default) If alarm source is set to input, select which input to use [ A.hy] Hysteresis [ 1.0] (Default) Set the hysteresis for an alarm. This determines how far into the safe region the process value needs to move before the alarm can be cleared [ A.Lg] Logic [ AL.C] for Close on Alarm (Default) Select what output condition will be during the alarm state [ A.Sd] Sides [high] for High Select which side or sides will trigger this alarm [ A.LA] Latching [nlat] for Non-Latching (Default) Turn alarm latching on or off. A latched alarm has to be turned off by the user [ A.bL] Blocking [ off] for Off (Default) Select when an alarm will be blocked. After startup and/or after the set point changes, the alarm will be blocked until the process value enters the normal range [ A.Si] Silencing [ off] for Off (Default) Turn alarm silencing on to allow the user to disable this alarm [A.dSP] Display Display an alarm message when an alarm is active [off] for Off * Only available on Dual Probe Controllers Setup Page Global Menu Display Parameter Name Description Select [ C_F] Display Units [ F] for vf (Default) Select which units will be displayed [AC.LF] AC Line Frequency Set the frequency to the applied ac line power [ 60] for 60 Hz (Default) Operations Page Due to conditions set in the SETUP PAGE, the DIGITAL INPUT/OUTPUT, PROFILE STATUS, and CURRENT Menus should not be needed for anything Operations Page Analog Input Menu Display Parameter Name Description Select [ Pv] * Process Value (Analog Input 1 or 2) - View the process value [ i.er] * Error Status (Analog Input 1 or 2) [none] for None (Default) View the cause of the most recent error [ i.ca] * Calibration Offset (Analog Input 1 or 2) Offset the input reading to compensate for lead wire resistance or other factors that cause the input reading to vary from the actual process value [ 2] (Default on Dual Probe Only) Must be changed on single probe modules * Only 1 Analog Input Available for the Single Probe Controllers A 19 of 43

20 * Operations Page Limit Menu Display Parameter Name Description Select [ LL.S] Low Set Point [0.0] (Default) Set the low process value that will trigger the limit [ i.er] High Set Point Set the high process value that will trigger the limit [ 275] (Fahrenheit) [ 135] (Celsius) * There is no Limit Menu for Single Probe Controllers Operations Page Monitor Menu Display Parameter Name Description Select [C.MA] Control Mode Active - View the current control mode [ h.pr] Heat Power [0.0] View the current heat output level [ C.Pr] Cool Power [0.0] View the current cool output level [ C.SP] Closed Loop Working Set Point [-] Displays the current Set Point View the set point currently in effect [ Pv.A] Process Value Active View the current filtered process value using the control input [-] Displays the current Process Value * Operations Page Alarm Menu Display Parameter Name Description Select [ A.hi] High Set Point Set the high process value that will trigger the limit [160] (Fahrenheit) [ 71] (Celcius) Operations Page Loop Menu Display Parameter Name Description Select [ C.M] Control Mode [AUto] for Auto (Closed Loop) (Default) Select the method that the controller will use to control [A.tSP] Autotune Set Point [ 90] (Default) Set the set point that Autotume will use, as a percentage of the current set point [ Aut] Autotune Request [no] for No (Default) Start an Autotune [ C.SP] Closed Loop Set Point Set the set point that the controller will automatically [130 F] or change to desired temperature [ 54 C] or change to desired temperature control to [ id.s] Idle Set Point [ 75] (Default) Set a closed loop set point that can be triggered by an event starter [ h.pb] Heat Proportional Band [ 25.0] (Default) Set the PID proportional band for the heat outputs [ ti] Time Integral [ 180] (Default) Set the PID integral for the outputs [ td] Time Derivative [0.0] (Default) Set the PED derivative time for the outputs [ o.sp] Open Loop Set Point Set a fixed level of output power when in manual (openloop) mode [0.0] (Default) *There are no Remote functions for the Single Probe Controllers A 20 of 43

21 Technical Data Category Electrical Power Weight Data V 50/60Hz, 1 phase for heat 11 kw max. (Qty 2) 4000W outputs for large heat blankets (Qty 2) 1500W Outputs for heated hoses kg (70 lbs) - 4 Control Zones Dimensions Figure 18: Box Dimensions Height Width Depth 20 in (508 mm) 10 in (25.4 mm) 24.8 in (630 mm) A 21 of 43

22 Wiring Diagrams LC0066 LOCIC, HEAT, V3, L1, (1) DP PAGE 1 OF A 22 of 43

23 LC0066 LOCIC, HEAT, V3, L1, (1) DP PAGE 2 OF A 23 of 43

24 LC0067 LOCIC, HEAT, V3, L1, (1) SP PAGE 1 OF A 24 of 43

25 LC0067 LOCIC, HEAT, V3, L1, (1) SP PAGE 2 OF A 25 of 43

26 LC0068 LOCIC, HEAT, V3, L2, (2) DP PAGE 1 OF A 26 of 43

27 LC0068 LOCIC, HEAT, V3, L2, (2) DP PAGE 2 OF A 27 of 43

28 LC0069 LOCIC, HEAT, V3, L2, (2) SP PAGE 1 OF A 28 of 43

29 LC0069 LOCIC, HEAT, V3, L2, (2) SP PAGE 2 OF A 29 of 43

30 LC0070 LOCIC, HEAT, V3, L2, (1) DP PAGE 1 OF A 30 of 43

31 LC0070 LOCIC, HEAT, V3, L2, (1) DP PAGE 2 OF A 31 of 43

32 LC0071 LOCIC, HEAT, V3, L3, (2) DP PAGE 1 OF A 32 of 43

33 LC0071 LOCIC, HEAT, V3, L3, (2) DP PAGE 2 OF A 33 of 43

34 LC0072 LOCIC, HEAT, V3, L3, (1) DP, (2) SP PAGE 1 OF A 34 of 43

35 LC0072 LOCIC, HEAT, V3, L3, (1) DP, (2) SP PAGE 2 OF A 35 of 43

36 LC0073 LOCIC, HEAT, V3, L3, (3) SP PAGE 1 OF A 36 of 43

37 LC0073 LOCIC, HEAT, V3, L3, (3) SP PAGE 2 OF A 37 of 43

38 LC0074 LOCIC, HEAT, V3, L4, (2) DP, (2) SP PAGE 1 OF A 38 of 43

39 LC0074 LOCIC, HEAT, V3, L4, (2) DP, (2) SP PAGE 2 OF A 39 of 43

40 LC0075 LOCIC, HEAT, V3, L4, (1) DP, (3) SP PAGE 1 OF A 40 of 43

41 LC0075 LOCIC, HEAT, V3, L4, (1) DP, (3) SP PAGE 2 OF A 41 of 43

42 LC0076 LOCIC, HEAT, V3, L4, (4) SP PAGE 1 OF A 42 of 43

43 LC0076 LOCIC, HEAT, V3, L4, (4) SP PAGE 2 OF A 43 of 43

User Instructions 711 HULMAN STREET PO BOX 2128 TERRE HAUTE, IN FAX

User Instructions 711 HULMAN STREET PO BOX 2128 TERRE HAUTE, IN FAX User Instructions 711 HULMAN STREET PO BOX 2128 TERRE HAUTE, IN 47802 812-235-6167 FAX 812-234-6975 OPERATING AND SAFETY INSTRUCTIONS for Digitrol II Temperature Control CATALOG #104A PL624CE, 10 amp,

More information

Instruction Notes for 104A PL912 Photos below are for reference only. Outlet. Figure 1 Figure 2

Instruction Notes for 104A PL912 Photos below are for reference only. Outlet. Figure 1 Figure 2 Operation Manual ON/OFF Switch Instruction Notes for 104A PL912 Photos below are for reference only. ON/OFF Alarm Switch Grid Support Digital Control Module Sensor Input Load Outlet Alarm RS-232 Port Figure

More information

Athena Bedros Hot Runner Controller Configuration and Operation Manual

Athena Bedros Hot Runner Controller Configuration and Operation Manual Athena Bedros Hot Runner Controller Configuration and Operation Manual Athena, CompuStep, and CompuCycle are registered trademarks and Bedros is a trademark of Athena Controls, Inc. 2012. Athena Controls,

More information

Athena Series RMC Hot Runner Controller Configuration and Operation Manual

Athena Series RMC Hot Runner Controller Configuration and Operation Manual Athena Series RMC Hot Runner Controller Configuration and Operation Manual Athena and CompuStep are registered trademarks, and Multi-Comm and SafeChange are trademarks of Athena Controls, Inc. MODBUS is

More information

Athena RMB/6 and RMB/12 Non-Modular Hot Runner Controller Configuration and Operation Manual

Athena RMB/6 and RMB/12 Non-Modular Hot Runner Controller Configuration and Operation Manual Athena RMB/6 and RMB/12 Non-Modular Hot Runner Controller Configuration and Operation Manual Athena, CompuStep, and CompuCycle are registered trademarks, and RMB/6 and RMB/12 are trademarks of Athena Controls,

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions CONTENTS Page

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

SERIES C 1ZC 16C 18C 19C 25C

SERIES C 1ZC 16C 18C 19C 25C SERIES C 1ZC 16C 18C 19C 25C TEMPERATURE / PROCESS CONTROLLER Controller Operator Manual Athena is a registered trademark and Multi-Comm is a trademark of Athena Controls, Inc. Platinel is a trademark

More information

THERM-O-FLOW EC-20/40 Timer

THERM-O-FLOW EC-20/40 Timer Instructions THERM-O-FLOW EC-20/40 Timer 310814B EN For use with THERM-O-FLOW Hot Melt Tanks. Model 118051 EC-20 two event timer for 115 VAC and 230 VAC Model 118052 EC-40 four event timer for 115 VAC

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

Indicators. Product Mounting Display Height Page

Indicators. Product Mounting Display Height Page Product Mounting Display Height Page EZ-ZONE PM 1 /32, 1 /16, 1 /8, 1 /4 DIN front panel Upper/Left: 0.30 to 0.80 in. (8 to 20 mm) Lower/Right: 0.22 to 0.50 in. (6 to 13 mm) 379 EZ-ZONE RUI and Gateway

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

Series RMT Hot Runner Controller Setup and Operation Manual

Series RMT Hot Runner Controller Setup and Operation Manual Series RMT Hot Runner Controller Setup and Operation Manual Littlefuse is a registered trademark of Littlefuse, Inc. G is a registered trademark of the DME Corporation. SafeChange is a trademark of Athena

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

BIOREP TEMPERATURE MONITOR MODEL No: BTM-01 USER MANUAL. Page 1 of 8

BIOREP TEMPERATURE MONITOR MODEL No: BTM-01 USER MANUAL. Page 1 of 8 BIOREP TEMPERATURE MONITOR MODEL No: BTM-01 USER MANUAL Page 1 of 8 TABLE OF CONTENTS 1 GETTING STARTED... 3 1.1 SYMBOLS USED IN THIS MANUAL... 3 1.2 MACHINE INFORMATION... 3 1.3 CONTACT INFORMATION...

More information

Series RMA Hot Runner Controller Setup and Operation Manual

Series RMA Hot Runner Controller Setup and Operation Manual Series RMA Hot Runner Controller Setup and Operation Manual Littlefuse is a registered trademark of Littlefuse, Inc. G is a registered trademark of the DME Corporation. SafeChange is a trademark of Athena

More information

OPERATION MANUAL FOR VP 741 SERIES HEATING BLOCKS

OPERATION MANUAL FOR VP 741 SERIES HEATING BLOCKS OPERATION MANUAL FOR VP 741 SERIES HEATING BLOCKS TECHNICAL NOTE 113D VP 741BW-R-MICA-A-1 On/Off Power Switch Heat Block Watlow Controller MICA SBS Adaptor Figure 1. Parts of a VP 741 Series Heating Block,

More information

Series SD6 with DeviceNet (Addendum)

Series SD6 with DeviceNet (Addendum) Series SD6 with (Addendum) Watlow s Series SD6 with offers excellent control and application flexibly in a 1/16th DIN panel mount package. The Series SD6 with has been successfully tested for use with

More information

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL UNITED STATES Contents Safety Information... 2 Save These Important Safety Instructions... 2 Warnings...2 Cautions...3 General Information... 4 Mobile Connector

More information

OWNER S MANUAL CD-2 V 1.3

OWNER S MANUAL CD-2 V 1.3 OWNER S MANUAL CD-2 V 1.3 2 TABLE OF CONTENTS WARNINGS... 3 ACCESSORIES... 4 REMOTE CONTROL... 5 FRONT PANEL... 6 REAR PANEL... 7 MENU SYSTEM... 8 NOTES OF IMPORTANCE... 10 CONNECTORS... 11 TECHNICAL SPECIFICATIONS...

More information

LED FOLDING WORKLIGHT TM

LED FOLDING WORKLIGHT TM LED FOLDING WORKLIGHT TM LED LIGHT POWERSTRIP USB CHARGING ITM. / ART. 689211 Model: LM55812 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY For assistance with assembly

More information

Gavita Master Controller EL1

Gavita Master Controller EL1 Gavita Master Controller EL1 User manual User manual Gavita Master controller EL1 Dear customer, Congratulations on the purchase of your Gavita Master controller EL1. This manual contains all the information

More information

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly

Input Power Selector Switch. Product Manual (Revision NEW) Original Instructions for use with Generator Set Control Assembly Product Manual 82017 (Revision NEW) Original Instructions 9900-471 for use with 8272-713 Generator Set Control Assembly Operation Manual General Precautions Read this entire manual and all other publications

More information

Tesla TI Generator Set Interface

Tesla TI Generator Set Interface Power Anytime, Anywhere Tesla TI2000-440 Generator Set Interface User Manual Built Smart...Proven Tough Tesla Industries, Inc. 101 Centerpoint Blvd. New Castle, DE 19720 (302) 324-8910 Phone (302) 324-8912

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL

USER'S GUIDE BARD-LINK TM LC /LC SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL USER'S GUIDE BARD-LINK TM LC1000-100/LC1500-100 SOLID STATE DUAL UNIT LEAD/LAG CONTROLLER & TEC-EYE HAND-HELD DIAGNOSTIC TOOL Bard Manufacturing Company, Inc. Bryan, Ohio 43506 Since 1914...Moving ahead,

More information

RAINPROOF* COLOR CAMERA SECURITY SYSTEM

RAINPROOF* COLOR CAMERA SECURITY SYSTEM RAINPROOF* COLOR CAMERA SECURITY SYSTEM Model 91202 ASSEMBLY AND OPERATING INSTRUCTIONS 3491 Mission Oaks Blvd., Camarillo, CA 93011 Visit our Web site at: http://www.harborfreight.com Copyright 2004 by

More information

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions

GRUNDFOS INSTRUCTIONS. Control MPC. Installation and operating instructions GRUNDFOS INSTRUCTIONS Control MPC Installation and operating instructions English (GB) English (GB) Installation and operating instructions Original installation and operating instructions These installation

More information

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G)

Control. Part B, Section 2. This section covers the following unit configurations. 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G) Part B, Section 2 Model This section covers the following unit configurations. 3100V 3400V 3500V Voltage 1, 2, 3 Pump Piston (D, E, F, G) Manifold 4-Port (A) 6-Port (B or C) 2-Port (S or T) Vista Temperature

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

Instructions for TPC Power Through Control Console

Instructions for TPC Power Through Control Console Visionary Solutions for Industry Since 1972 ISO 9001 Certified Temperature Controllers & Sensors Heating Elements Process Heating Systems Instructions for TPC Power Through Control Console SPECIFICATIONS

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

OLS VT10 SERIES STANDARD DUAL DISPLAY PID AUTOTUNE RAMP-TO-SETPOINT ULC, UL, CE (4810) AUTO / MANUAL 15 SECURITY OPTIONS UNIVERSAL INPUT

OLS VT10 SERIES STANDARD DUAL DISPLAY PID AUTOTUNE RAMP-TO-SETPOINT ULC, UL, CE (4810) AUTO / MANUAL 15 SECURITY OPTIONS UNIVERSAL INPUT TEMPERATURE TURE CONTROLS OLS VT10 SERIES pg.1 STANDARD DUAL DISPLAY PID AUTOTUNE RAMP-TO-SETPOINT ULC, UL, CE (4810) AUTO / MANUAL 15 SECURITY OPTIONS UNIVERSAL INPUT OPTIONS DUAL OUTPUT ALARMS - 15 TYPES

More information

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions

3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions 3M Duplex Polishing Machine 6851-E with Universal Dual Holder Instructions Safety Information Read, understand and follow all safety information contained in these user instructions prior to use of the

More information

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. WARNING Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. CONTENTS 1. The company..2 2. Specifications.. 3 3. Package Contents..5 4. Installation, Fix and Transport..6

More information

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN

Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Installation and Operation Back-UPS BR1000G-IN / BR1500G-IN Important Safety Information Read the instructions carefully to become familiar with the equipment before trying to install, operate, service

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

SP6R Level Controller Operation Manual

SP6R Level Controller Operation Manual SP6R Level Controller Operation Manual www.sjerhombus.com SP6R LEVEL CONTROLLER INTRODUCTION SJE-Rhombus, an industry leader in water and wastewater pump controls, introduces the SP6R Level Controller.

More information

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1000 Part No. 23624 OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1000 OV1000 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V

CRAGG RAILCHARGER Instruction Manual for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V CRAGG RAILCHARGER for 10DTC-12V 20DTC-12V 30DTC-24V 40DTC-12V 60DTC-12V Contents 1 Warnings, Cautions, and Notes... 1 2 Description... 2 3 Features... 2 3.1 STANDARD FEATURES... 2 3.2 CHARGER REGULATION...

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

TC-9102 Series Surface Mount Temperature Controllers

TC-9102 Series Surface Mount Temperature Controllers TC-9102 Series Surface Mount Temperature Controllers General Description & Applications The TC-9102 Series Temperature Controller offers a versatile solution for a wide variety of applications that may

More information

PR3400 Series 1.4Mp USB Cameras Hardware Guide

PR3400 Series 1.4Mp USB Cameras Hardware Guide PR3400 Series 1.4Mp USB Cameras Hardware Guide Manufactured by: SPOT Imaging Solutions, a division of Diagnostic Instruments, Inc. 6540 Burroughs Ave. Sterling Heights, MI 48314-2133 USA Toll-Free: 866-604-SPOT

More information

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS EN0I-6041 12/99 PRODUCT SPECIFICATION SHEET OVERVIEW The UDC 1000 and UDC 1500 are microprocessor-based 1/16 DIN and 1/8 DIN controllers

More information

Haze 800 DMX. User Guide. English

Haze 800 DMX. User Guide. English Haze 800 DMX User Guide English Introduction Box Contents Haze 800 DMX Remote Control (wired) User Guide Safety & Warranty Manual Support For the latest information about this product (documentation, technical

More information

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series Owner s Manual 19 Pro Series Rack Mount (RK) Faceplate Isolate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) Colours Restore. Power Conditioners Audio / Video Power Isolation

More information

Instructions for Switched TPC Series Control Consoles

Instructions for Switched TPC Series Control Consoles Visionary Solutions for Industry Since 1972 ISO 9001 Certified Temperature Controllers & Sensors Heating Elements Process Heating Systems Instructions for Switched TPC Series Control Consoles SPECIFICATIONS

More information

Int3233. Soldering Station. Instruction Manual

Int3233. Soldering Station. Instruction Manual Int3233 Soldering Station Instruction Manual Thank you for purchasing the Aoyue int 3233 Soldering Station. Please read the manual before using the unit. Keep manual in accessible place for future reference.

More information

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE

PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE PNP415 PNP417 with tabletop cutout installed. MANUAL PART NUMBER: 400-0427-002 PNP415/417 POP 'N PLUG WITH CUSTOM TABLETOP SURFACE USER'S GUIDE TABLE OF CONTENTS Page PRECAUTIONS / SAFETY WARNINGS... 2

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

Precautions. Please read carefully before using this product.

Precautions. Please read carefully before using this product. Thank you for purchasing this BEWITH Mirror Media MM-1. It is designed to give you many years of enjoyment. Please read all instructions in this manual before attempting operation and keep it handy for

More information

DC100 Digital Dispenser Operating Manual

DC100 Digital Dispenser Operating Manual DC100 Digital Dispenser Operating Manual 2015 Fisnar Phone: (262)253-8600 E-mail: info@fisnar.com Table of Contents Product Safety Statement 4 Specifications 6 Accessories 6 External Controls 7 Machine

More information

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part # 4-20mA Display Installation and Operation Manual Rev 4/3/2019 Part # 12050769 Table of Contents DOCUMENTATION CONVENTIONS... 2 Section 1: System Description... 3 Function and Theory... 3 Section 2: System

More information

RS Stock No Instruction Manual RS Input Data Logging Thermometer

RS Stock No Instruction Manual RS Input Data Logging Thermometer RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2

More information

Blitzer Strobe. User Manual. Order code: EQLED366

Blitzer Strobe. User Manual. Order code: EQLED366 Blitzer Strobe User Manual Order code: EQLED366 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please make

More information

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: + 31

More information

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS

A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS Document Number: 9100-127-2301-99 Release Date: 2/2/15 A0/A1 Controller Assembly Operation/Installation Manual READ AND FOLLOW ALL SAFETY INSTRUCTIONS DO NOT let any supply cords touch hot surfaces higher

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

CARLO GAVAZZI Automation Components

CARLO GAVAZZI Automation Components CARLO GAVAZZI Automation Components UDM 35/40 Digital Panel Meter Programming Guide Index Description 2 Programming Fundamentals 3 Access to Programming Mode/Password Protection 4 Programming 5-18 Inputs

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy EZ-ZONE ST EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy Watlow s new EZ-ZONE ST integrated control loop solid state controller offers complete thermal system

More information

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

TECHCONNECT TC2-HDMI14 OWNERS MANUAL TECHCONNECT TC2-HDMI14 OWNERS MANUAL www.visionaudiovisual.com/techconnect/tc2-hdmi14 1 DECLARATION OF CONFORMITY Where applicable Vision products are certified and comply with all known local regulations

More information

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS

ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE SAFETY PRECAUTIONS ELECTRICAL SUPPLY TROUBLESHOOTING QUICK GUIDE 1. Circuit Breaker Tripping 2. Circuit Overload 3. Short Circuit 4. Ground Fault 5. Ground Fault Circuit Interrupter (GFCI) Tripping SAFETY PRECAUTIONS Basic

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

Quantum HD Release Notes

Quantum HD Release Notes Quantum HD Release Notes OS Version 10.17 Released 7-14-2014 To upgrade to OS version 10.17 directly the current OS version must be 10.13 through 10.16. To check the current OS version on the Quantum HD

More information

RGB Power Batten. User Manual. Order code: EQLED032

RGB Power Batten. User Manual. Order code: EQLED032 RGB Power Batten User Manual Order code: EQLED032 Safety advice WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CARE- FULLY BEFORE YOUR INITIAL START-UP! Before your initial start-up, please

More information

Replacing a Precision Controller Circuit Board

Replacing a Precision Controller Circuit Board Instruction heet Replacing a Precision Controller Circuit Board WARNING: Allow only qualified personnel to perform the following tasks. Observe and follow the safety instructions in this document and all

More information

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444

RVDT Setup and Polarity Checking Tool for EG Governors. Product Manual (Revision B) Original Instructions T87444 Product Manual 01504 (Revision B) Original Instructions RVDT Setup and Polarity Checking Tool for EG Governors T87444 Operation and Calibration Manual General Precautions Read this entire manual and all

More information

Application Note (Revision NEW) Original Instructions. Wiring Instructions for 2301A Controls Replacing Caterpillar 2301 Controls

Application Note (Revision NEW) Original Instructions. Wiring Instructions for 2301A Controls Replacing Caterpillar 2301 Controls Application Note 51191 (Revision NEW) Original Instructions Wiring Instructions for 2301A Controls Replacing Caterpillar 2301 Controls General Precautions Read this entire manual and all other publications

More information

Application Note (Revision NEW) Original Instructions. EGCP-2 Differences

Application Note (Revision NEW) Original Instructions. EGCP-2 Differences Application Note 51199 (Revision NEW) Original Instructions General Precautions Read this entire manual and all other publications pertaining to the work to be performed before installing, operating, or

More information

Mini Digital Multimeter Model MN15. User's Guide

Mini Digital Multimeter Model MN15. User's Guide Mini Digital Multimeter Model MN15 User's Guide Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

F4 Temperature/Humidity Controller User s Manual

F4 Temperature/Humidity Controller User s Manual F4 Temperature/Humidity Controller User s Manual TestEquity LLC 6100 Condor Drive Moorpark, CA 93021 Support: 877-512-3457 Toll Free 805-480-0638 Corporate: 800-732-3457 805-498-9933 http://www.testequity.com

More information

FengMi Wemax One Laser Projection TV

FengMi Wemax One Laser Projection TV FengMi Wemax One Laser Projection TV User`s Manual About electrical ground Transportation Use this device only with a compulsory grounding condition. It is recommended that you use the original packaging

More information

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11 Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11 2011 Ashcroft Inc. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402

More information

TVA2.1 2-Channel Digital Amplifier Installation Manual

TVA2.1 2-Channel Digital Amplifier Installation Manual TVA2.1 2-Channel Digital Amplifier Installation Manual SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT EXPOSE THIS APPLIANCE TO RAIN OR MOISTURE. CAUTION: TO REDUCE THE

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

Orion-M iseries Interface

Orion-M iseries Interface Orion-M iseries Interface Multi-loop Control System Configuration Manual Orion-M iseries Control System Configuration Manual Rev A March 25, 2010 Supersedes: - Safety Information in this Manual Notes,

More information

Operating and installation instructions Differential pressure monitor

Operating and installation instructions Differential pressure monitor Operating and installation instructions Differential pressure monitor RM-DPC Micro SensorLine Table of contents 1 Safety instructions...3 2 Equipment specification...3 3 Assembly...4 4 Step-by-step installation...4

More information

DMX LED Starcloth Systems

DMX LED Starcloth Systems DMX LED Starcloth Systems User Manual Order codes: 3 x 2m with Stand & Bag Set (Black cloth, CW) - STAR01 2.2 x 1m DJ Skirt (Black cloth, CW) - STAR04 3 x 2m (Black cloth, CW) - STAR05 3 x 2m (White cloth,

More information

ICE FOG Q TM Low Fog Generator

ICE FOG Q TM Low Fog Generator Low Fog Generator USER GUIDE Revision A/d, May 2017, MDG Fog Generators Ltd MADE IN CANADA FABRIQUÉ AU CANADA Les Générateurs de Brouillard MDG Ltée / MDG Fog Generators Ltd 10301 avenue Pelletier, Montréal,

More information

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS

PDS100 Programmable Dispensing System SAFETY INSTRUCTIONS PDS100 Programmable Dispensing System INSTRUCTION MANUAL SAFETY INSTRUCTIONS Before using any Fluid Metering, Inc. product read the following safety instructions as well as specific product specifications

More information

Model P4470 Save A Watt Operation Manual

Model P4470 Save A Watt Operation Manual Model P4470 Save A Watt Operation Manual Thank you for purchasing the P4470 Save A Watt. This operating manual will provide an overview of the product, safety instructions, a quick guide to operation,

More information

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE

SPECIAL APPLICATION MANUAL PART NUMBER: TNP121UL. Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE MANUAL PART NUMBER: 400-0429-001 TNP121UL Tilt N Plug Jr. Table Top Interconnect Box USER'S GUIDE INTRODUCTION Your purchase of the UL Listed TNP121UL, Tilt N Plug Jr. Interconnect Box is greatly appreciated.

More information

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown TOT Series Manual North American and International Models - without optional faceplate Receptacle Panel of International Models, CE model shown North American Models Table of Content 1. Important Safety

More information

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models TOT Series Manual North American CE and UK Models CE Models UK Models North American Models Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement

More information

Owner's Manual RBC-5000

Owner's Manual RBC-5000 Owner's Manual RBC-5000 High Speed Bill Counter With Ultraviolet, Magnetic and Infrared Counterfeit Detection Royal Sovereign International, Inc. Please read and retain these instructions. To register

More information

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere!   Toll Free Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883 Standard Features Structure Units available in standard

More information

The Temperature Control Company SERIES RMB HOT RUNNER CONTROLLER. Instruction Manual

The Temperature Control Company SERIES RMB HOT RUNNER CONTROLLER. Instruction Manual The Temperature Control Company SERIES RMB HOT RUNNER CONTROLLER Instruction Manual Athena Controls, Inc. 5145 Campus Drive Plymouth Meeting, PA 19462 Phone: 610-828-2490 Fax: 610-828-7084 www.athenacontrols.com

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Owner s Manual & Safety Instructions

Owner s Manual & Safety Instructions Owner s Manual & Safety Instructions Save This Manual Keep this manual for the safety warnings and precautions, assembly, operating, inspection, maintenance and cleaning procedures. Write the product s

More information

Cantata m100 Amplifier

Cantata m100 Amplifier Cantata m100 Amplifier Getting Started Guide www.resolutionaudio.com +1.415.553.4100 Safety Information CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO

More information

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE OV1001 Part No. 23620 OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE PRODUCT OVERVIEW User Guide: OV1001 OV1001 HEIGHT ADJUSTABLE TABLE A healthier work environment starts with the option to sit or stand throughout

More information

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL This manual contains important safety information about installation and use of this equipment. Ignoring this information could result in injuries or damages. It is strictly forbidden to use this equipment

More information

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i

More information

BASIC OPERATION OF L&L KILNS WITH A DYNATROL

BASIC OPERATION OF L&L KILNS WITH A DYNATROL Press the START/STOP Button to start firing the program you have selected. You can also stop a program from firing. The Vary-Fire section is for advanced users. Press Review Prog to see what program you

More information

USER'S MANUAL DCL-650

USER'S MANUAL DCL-650 USER'S MANUAL Clamp on Multimeter - Compact Design True RMS AC/DC DCL-650 CIRCUIT-TEST ELECTRONICS www.circuittest.com Safety International Safety Symbols This symbol, adjacent to another symbol or terminal,

More information

SI3300. user and installation manual. 4-20mA/DC-Digital Display

SI3300. user and installation manual. 4-20mA/DC-Digital Display SI3300 4-20mA/DC-Digital Display The SI3300 is a member of the SI3000 Readout Family. All members of the family are marked SI3000 on the front panel. This manual is specifically for the SI3300 Model with

More information

You can reach our technical support team by phoning or visiting

You can reach our technical support team by phoning or visiting You can reach our technical support team by phoning 216.367.7000 or visiting www.ppe.com II Precautions Warning Use of this equipment in a manner not specified by the manufacturer may impair protection

More information

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels.

This Datasheet for the IC660BBA101. Block 115Vac/125Vdc RTD Input 6 Channels. This Datasheet for the IC660BBA101 Block 115Vac/125Vdc RTD Input 6 Channels http://www.qualitrol.com/shop/p-14423-ic660bba101.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information