1 MODBUS DISPLAY WITH ALARM AND ANALOG OUTPUTS DATASHEET F193 MODBUS DISPLAY Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe available ATEX and IECEx approval for gas and dust applications. Programming can be done by your own crew, with the sensible menudriven structure, saving cost and irritation. Know one, know them all! Very diverse mounting possibilities: walls, pipes, panels or directly onto outdoor sensors! Features Fully controlled through Modbus ASCII / RTU communication protocol. 9 different product / tank values can be displayed. Displays actual value, product / tank I.D., measuring unit, status and alarm messages. Actual values are operator selectable or with the automatic toggle function. Alarms can be terminated through communication or after operator interaction. Actual value: six large 17mm (0.67") digits. Explosion/flame proof available. Loop or battery powered, 8 24V AC/DC or V AC. 1 Signal output 4 20mA / 0 10 V DC output retransmitting any value set through communication the output can be scaled to any previously set range. Up to four configurable alarm outputs controlled through communication or related to the actual product / tank values. Signal input None. Applications The FSeries is your first and safest choice for field mount indicators in safe and hazardous area applications. Especially in harsh weather conditions like rain, snow, salty atmospheres and temperatures between 40 C up to 80 C (40 F up to 176 F). Local indication and monitoring of process parameters where the actual information is provided through a Modbus communication link and not a sensor. For DIN panel mount indicators, check our DSeries.
2 General information Introduction The F193 is a versatile large digit Modbus display. All displayed information and signal outputs are controlled through the Modbus ASCII / RTU communication protocol. Information of nine different tanks or products can be displayed with an automatic toggle function or can be selected by the operator. Offcourse, it can also be selected and locked through communication. A wide range of options further enhance this models capabilities, including Intrinsic Safety for hazardous area applications. Display The display has large 17mm segments which can be set to show actual value. Onscreen engineering units are easily configured from a comprehensive menu, whilst different units for product / tank I.D. can be displayed simultaneously. The status and alarm messages can register up to 11 digits. Alarm outputs Up to four control or alarm outputs can be controlled directly or being linked to an alarm status of the nine products: an alarm message will be displayed and the related relay(s) switched. The output signal can be a passive NPN, active PNP or an isolated electromechanical relay. Communication All displayed information and signal outputs are controlled through the Modbus ASCII / RTU communication protocol (RS232 / RS485). Full Modbus functionality remains available for the Intrinsically Safe version (TTL). Hazardous areas This model has been ATEX and IECEx certified Intrinsically Safe for gas and dust applications, with an allowed ambient temperature of 40 C to 70 C (40 F to 158 F). A flame proof Ex d enclosure with ATEX certification is also available. Configuration All configuration settings are accessed via a simple operator menu which can be password protected. Each setting is clearly indicated with an alphanumerical description, which avoids confusing abbreviations and baffling codes. Once familiar with one Fseries product, you will be able to program all models in the series without a manual. All settings are safely stored in EEPROM memory in the event of sudden power loss. Enclosures Various types of enclosures can be selected, all ATEX and IECEx approved. As standard the F110 is supplied in an GRP panel mount enclosure, which can be converted to an IP67 / NEMA Type4X GRP field mount enclosure by the addition of a back case. Most popular is our rugged aluminum field mount enclosure with IP67 / NEMA Type4X rating. Both European or U.S. cable gland entry threads are available. Analog output signal Overview application F193 Also available is an (0)4 20mA or 0 10V DC output signal, fully controlled through the communication. For security reasons, all outputs can be switchedoff automatically in case of a communication breakdown. The output signal is updated eight times per second with a filter functi Alarm output 1 Alarm output 2 Alarm output 3 Alarm output 4 Analog output on being available to smooth the signal if desired. The output signal can be passive, active or isolated where the passive output type will loop power the F193 as well. Communication link 2 F193
3 I I I Dimensions enclosures Aluminum & GRP panel mount enclosure Terminal connections Aluminum & GRP field / wall mount enclosures CB: RS232 RXD TXD 31 mm (1.22") 29 mm (1.14") 120 mm (4.72") 130 mm (5.12") HB & HC enclosures 130 mm (5.12") 115 (4.53") 98 (3.86") panel cutout Ø 7mm (0.27") Ø 7mm (0.27") COMMUNICATION V CH: RS485 2 wire A B CI: RS485 4 wire Y Z A B CT: TTL Intrinsically Safe RXD TXD 12V 120 mm (4.72") Aluminum 30mm 30mm PG9 M20 x 1,5 PG9 1.18" 1.18" 0.9" HA HL 75 mm (2.95") 60 mm (2.36") HD HE 112 mm (4.40") GRP 30mm 30mm ALARM OUTPUT OA: active 24V DC OT: passive trans. 1 /2"NPT 1 /2"NPT Ø16 Ø20 Ø16 30mm 30mm HM HF (0.9") M16 x 1,5 M20 x 1,5 M16 x 1,5 Ø22 ( 7 / 8") HN HG 25mm 25mm ANALOG OUTPUT AA: 4 20mA I AB: 0 20mA I AF: 4 20mA I I AI: 4 20mA I I AP: 4 20mA I AU: 0 10V U U 25mm M20 x 1,5 25mm M20 x 1,5 M20 x 1,5 12mm 12mm 24mm 24mm 36mm 36mm 6 x M12 14mm 17mm 0.9" HO HP HT HH HJ HK Ø20 Ø20 12mm 12mm 24mm 24mm Ø12 36mm 36mm 30mm (1.18") 30mm (1.18") Ø22 ( 7 / 8") Ø22 ( 7 / 8") Ø22 ( 7 / 8") 14mm 17mm (0.9") POWER REQUIREMENTS ALARM OUTPUT 2 ALARM OUTPUT PD: 8 24V AC OA: active 24V DC OA: active 24V DC PD: 8 24V DC OT: passive trans. OT: passive trans. PD XI: 16 30V DC OR: mech. relay OR: mech. relay = = = = PF: 24V AC PF: 24V DC PM: V AC PX: 8 30V DC ZB: Backlight: 12 30V DC AP PX: 8 30V DC Output loop powered PB / PC: battery powered Internal long life Lithium battery 1 /2"NPT 1.18" 1.18" Flat bottom, no holes available. Display example 90 x 40mm (3.5 x 1.6 ) 0.9" HU 1 /2"NPT 1 /2"NPT 1 /2"NPT 15mm 15mm 16mm 15mm HV 38mm 4 x M20 x 1.5 HZ F193 3
4 Typical wiring diagram F193APCHOTPX Typical wiring diagram F193AACBOAPD F100series OUTPUT LOOP POWERED F100series 24V AC / DC POWER SUPPLY Modbus communication type CH: RS485 2 wire Modbus communication type CB: RS232 B A TXD RXD 12V Switch output type OA: active 24V DC signal Analog output type AP: passive 4 20mA (loop powered) V DC Analog output type AA: active 4 20mA Power supply type PX: 8 30V DC (not used in this example) Main supply Power supply type PD: 8 24V AC/DC Switch output type OA: active 24V DC signal* Switch output type OA: active 24V DC signal* 8 24V AC 8 24V DC * Requires min. 24V power supply 4 F193
5 Typical wiring diagram F193AICIORPM Typical wiring diagram F193APCBOSPD F100series V AC POWER SUPPLY F100series 24V AC / DC POWER SUPPLY Z Y B A Modbus communication type CI: RS485 4 wire TXD RXD 12V Modbus communication type CB: RS V DC Switch output type OS: mechanic relay L V AC / DC N Analog output type AP: passive 4 20mA (loop powered) Analog output type AI: passive isolated 4 20mA 8 30V DC V DC Main supply Switch output type OR: mechanic relay Power supply type PM: V AC N L1 Main supply Power supply type PD: 24V AC / DC 24V AC 24V DC F193 5
6 Hazardous area applications The F193XI has been certified according ATEX and IECEx by DEKRA for use in Intrinsically Safe applications with an ambient temperature of 40 C to 70 C (40 F to 158 F). The ATEX markings for gas and dust applications are: II 1 G Ex ia IIB/IIC T4 Ga II 1 D Ex ia IIIC T100 C Da. The IECEx markings for gas and dust applications are: Ex ia IIC/IIB T4 Ga and Ex ia IIIC T100 C Da. It is allowed to connect up to six barriers in IIB/IIIC applications, the F193 is not suitable for IIC applications. Consult the certificate for the maximum input and output values of the circuits. Full functionallity of the F193 remains available, including Modbus communication type CT. An ATEX approved flame proof Ex d enclosure is available as well. Please contact your supplier for further details. Certificate of conformity KEMA 03ATEX1074 X IECEx DEK X Configuration example IIB / IIIC and IIIC F193APCTOTPXXI Output loop powered F100series HAZARDOUS AREA SAFE AREA Modbus communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. TXD RXD 12V Ci = 17nF Analog output type AP PX: passive 4 20mA (output loop powered) Ci is negligibly small Ci is negligibly small ISOLATOR: Uo=max 30V I.S. Certified Isolator Io=max 250mA TTL to RS232 / RS422 / TTL Po=max 850mW For example: MTL5051 Uo=max 30V Uo=max 30V POWER SUPPLY e.g. MTL 5525 and / or REPEATER e.g. MTL 5541 POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. PC * Note: Communication only allowed when configured as IIB / IIIC. e.g. sounder Uo=max 30V POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 e.g. sounder Note: above values are safety values. Consult the technical specification for operational values. 6 F193
7 Configuration example IIB / IIIC and IIIC F193AFCTOTPDXI Power requirement 16 30V DC F100series HAZARDOUS AREA SAFE AREA TXD RXD 12V Modbus communication type CT: TTL Please note: communciation type CT is not allowed in IIC applications. ISOLATOR: Uo=max 30V I.S. Certified Isolator TTL to Io=max 250mA RS232 / RS422 / TTL Po=max 850mW For example: MTL5051 e.g. PC * Note: Communication only allowed when configured as IIB / IIIC. TOTAL Co OF ALL CONNECTED ANALOG APPARATUS IN IIC APPLICATIONS MAY NOT EXCEED 66nF MINUS 17nF (17nF IS USED BY THE ANALOG OUTPUT SIGNAL TERMINAL 7 8). Main supply Ci = 17nF Ci is negligibly small Ci is negligibly small Analog output type AF: passive floating 4 20mA Power supply type PD: 16 30V DC (please note: PD and battery supply (type PC) is NOT allowed in IIC applications). Uo=max 30V Uo=max 30V Uo=max 30V POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 POWER SUPPLY e.g. MTL 5525 or SWITCH INTERFACE e.g. MTL 5511 POWER SUPPLY For example MTL 5525 e.g. sounder e.g. sounder Note: above values are safety values. Consult the technical specification for operational values. F193 7
8 Technical specification General Display Type High intensity reflective numeric and alphanumeric LCD, UVresistant. Dimensions 90 x 40mm (3.5 x 1.6 ). Digits Seven 17mm (0.67") and eleven 8mm (0.31") digits. Various symbols and measuring units. Refresh rate User definable: fast, 1sec, 3sec, 15sec, 30sec, off. Option ZB Transflective LCD with white LEDbacklight. Good readings in full sunlight and darkness. Note ZB Only available for safe area applications. Ambient temperature Safe areas 40 C to 80 C (40 F to 176 F). Intrinsically Safe 40 C to 70 C (40 F to 158 F). Power requirements Type AP Analog output loop powerd, 8 30V DC. Power consumption max 0.5 Watt. Type PB Long life Lithium battery lifetime depends upon settings and configuration up to 5 years. (requires PD or PX) Type PC Intrinsically Safe long life lithium battery lifetime depends upon settings and configuration up to 5 years. (requires XI and PD or PX) Type PD 8 24V AC / DC ± 10%. Power consumption max. 5 W. Type PDXI 16 30V DC power consumption max. 1 Watt. Type PDOS 20 30V DC / 15 24V AC power consumption max. 1 W. Type PF 24V AC / DC ± 10%. Power consumption max. 15 Watt. Type PM V AC ± 10%. Power consumption max. 15 Watt. Type PX 8 30V DC. Power consumption max Watt. Type ZB 12 30V DC ± 10%. Power consumption max. 1.5 Watt. Note PB/PF/PM Not availble Intrinsically Safe. Note PF/PM The total consumption of the sensors and outputs may not exceed 24V. Note For Intrinsically Safe applications, consult the safety values in the certificate. Terminal connections Type Removable plugin terminal strip. Wire max. 1.5mm 2 and 2.5mm 2. Data protection Type EEPROM backup of all settings. Data retention at least 10 years. Password Configuration settings can be password protected. Enclosure General Window Sealing Control keys Polycarbonate window. Silicone. Three industrial microswitch keys. UVresistant silicone keypad. Aluminum wall / field mount enclosures General Diecast aluminum wall/field mount enclosure IP67 / NEMA Type4X with 2component UVresistant coating. Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") W x H x D. Weight 1100 gr. Type HA Cable entry: 2 x PG9 and 1 x M20. Type HL Cable entry: 3 x 1 / 2 " NPT. Type HM Cable entry: 2 x M16 and 1 x M20. Type HN Cable entry: 1 x M20. Type HO Cable entry: 2 x M20. Type HP Cable entry: 6 x M12. Type HT Cable entry: 1 x 1 / 2 " NPT. Type HU Cable entry: 3 x 1 / 2 " NPT. Type HV Cable entry: 4 x M20. Type HZ Cable entry: no holes. GRP wall / field mount enclosures General GRP wall/field mount enclosure IP67 / NEMA Type4X, UVresistant and flame retardant. Dimensions 130 x 120 x 75mm (5.12" x 4.72" x 2.95") W x H x D. Weight 600 gr. Type HD Cable entry: no holes. Type HE Cable entry: 2 x Ø 16mm and 1 x Ø 20mm. Type HF Cable entry: 1 x Ø 22mm ( 7 / 8 "). Type HG Cable entry: 2 x Ø 20mm. Type HH Cable entry: 6 x Ø 12mm. Type HJ Cable entry: 3 x Ø 22mm ( 7 / 8 "). Type HK Flat bottom, cable entry: no holes. Panel mount enclosures Dimensions 130 x 120 x 60mm (5.12" x 4.72" x 2.36") W x H x D. Panel cutout 115 x 98mm (4.53" x 3.86") L x H. Type HB Diecast aluminum panel mount enclosure IP65 / NEMA Type4X. Weight 600 gr. Type HC GRP panel mount enclosure IP65 / NEMA Type4X, UVresistant and flame retardant. Weight 450 gr.. Directives & Standards EMC Directive 2014/30/EU, FCC 47 CFR part 15. Low voltage Directive 2014/35/EU RoHS Directive 2011/65/EU ATEX / IECEx Directive 2014/34/EU, IEC , IEC IP & NEMA EN & NEMA F193
9 Hazardous area Intrinsically Safe (Type XI) ATEX II 1 G Ex ia IIB/IIC T4 Ga. certification II 1 D Ex ia IIIC T100 C Da. IECEx Ex ia IIC/IIB T4 Ga. certification Ex ia IIIC T100 C Da. Ambient Ta 40 C to 70 C (40 F to 158 F). Explosion proof (Type XF) ATEX certification II 2 G / Ex d IIB T5 Gb. II 2 D / Ex t IIIB T100 C Db. Type XF Dimensions of enclosure: 300 x 250 x 200mm (11.8" x 9.9" x 7.9") L x H x D. Weight Appr. 15kg. Note IECEx available on request. Signal inputs Communication Function Writing display information, controlling the analog and alarm outputs, reading / writing all settings. Protocol Modbus ASCII / RTU. Speed baud. Addressing Maximum 255 addresses. Type CB RS232 Type CH RS485 2wire Type CI RS485 4wire Type CT TTL Intrinsically Safe. Signal outputs Analog output Function Transmitting any value set through communication. Accuracy 10 bit. Error < 0.05%. Analog output signal can be scaled to any desired range. Update time Eight times per second. Type AA Active 4 20mA output (requires PD, PF, PM or PX). Type AB Active 0 20mA output (requires PD, PF, PM or PX). Type AF Passive floating 4 20mA output for Intrinsically Safe applications (requires XI PD). Type AI Passive galvanically isolated 4 20mA output also available for battery powered models. Type AP Passive 4 20mA output not isolated. Unit will be loop powered. Type AU Active 0 10V DC output (requires PD, PF, PM or PX). Requires min. 12V power supply. Digital outputs Function Transmitting an alarm condition or to control a device through communication. Type OA Three active 24V DC transistor outputs (PNP); max. 50mA per output (requires PD, PF, PM or PX). Requires min. 24V power supply. Type OR Two electromechanical relay outputs isolated (N.O.) max. switch power 230V AC 0.5A (requires PF or PM) and one transistor output OT. Type OS Four electromechanical relay outputs isolated; max. switch power 230V AC 0.5A per relay (requires AP and PD). Type OT Three outputs (NPN) not isolated. Max. 50V DC 300mA per output. Note Intrinsically Safe applications: only two transistor outputs type OT available. Operational Operator functions Displayed Nine different product or tank values. functions Actual value. Product / tank I.D. Alarm messages. Value Digits 7 digits. Units L, m3, GAL, USGAL, kg, lb, bbl, no unit. Decimals or 3. Accessories Mounting accessories ACF02 Stainless steel wall mounting kit. ACF05 Stainless steel pipe mounting kit (worm gear clamps not included). ACF06 Two stainless steel worm gear clamps Ø 44 56mm. ACF07 Two stainless steel worm gear clamps Ø 58 75mm. ACF08 Two stainless steel worm gear clamps Ø 77 95mm. ACF09 Two stainless steel worm gear clamps Ø mm. ACF11 Swivel with 25 movement from center axis for direct flowmeter mounting: 1 NPT to 1/2 NPT. Cable glands ACF20 ACF25 ACF26 ACF27 ACF28 ACF29 ACF32 ACF33 ACF34 ACF35 ACF39 ACF40 For HA enclosure, includes Orings. For HE enclosure, includes locknuts and Orings. For HF enclosure, includes locknuts and Orings. For HG enclosure, includes locknuts and Orings. For HH enclosure, includes locknuts and Orings. For HJ enclosure, includes locknuts and Orings. For HM enclosure, includes Orings. For HN enclosure, includes Orings. For HO enclosure, includes Orings. For HP enclosure, includes Orings. For HT enclosure, includes Orings. For HU enclosure, includes Orings. Intrinsically Safe isolators ACG01 MTL5511 One channel pulse or switch output transfer from hazardous area to safe area. ACG02 MTL5525 One channel power supply from safe area to hazardous area (e.g. to power the unit with PD or to power a switching or analog device in hazardous area). ACG03 MTL5541 One channel 4 20mA repeater from hazardous area to safe area. ACG04 MTL 5051 Bidirection serialdataisolator (for Modbus communication). ACG05 MTL5516C Two channel pulse or switch output transfer from hazardous area to safe area. ACG06 MTL5513 One channel pulse or switch output transfer from hazardous area to safe area. ACG07 MTL5546Y One channel isolated driver bringing 4 20mA from safe area to hazardous area, HART transparent, OCD. F193 9
10 Ordering information Standard configuration: F193XAPCHHCOTPXXXZX. Ordering information: F193 X A _ C _ H _ O _ P _ X _ Z _ Sensor input signal X No sensor input signal. Analog output signal AA Active 4 20mA output requires PD, PF, PM or PX. AB Active 0 20mA output requires PD, PF, PM or PX. AF I.S. floating 4 20mA output requires XI PD. AI Isolated 4 20mA output. AP Passive 4 20mA output, loop powered unit. AU Active 0 10V DC output requires PD, PF, PM or PX. Communication CB Communication RS232 Modbus ASCII / RTU. CH Communication RS485 2wire Modbus ASCII / RTU. CI Communication RS485 4wire Modbus ASCII / RTU. CT Intrinsically Safe TTL Modbus ASCII / RTU. Panel mount enclosures IP65 / NEMA Type4X HB Aluminum enclosure. HC GRP enclosure. GRP field / wall mount enclosures IP67 / NEMA Type4X HD Cable entry: no holes. HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm. HF Cable entry: 1 x Ø 22mm ( 7 /8 ). HG Cable entry: 2 x Ø 20mm. HH Cable entry: 6 x Ø 12mm. HJ Cable entry: 3 x Ø 22mm ( 7 /8 ). HK Flat bottom, cable entry: no holes. Aluminum field / wall mount enclosures IP67 / NEMA Type4X HA Cable entry: 2 x PG9 & 1 x M20. HL Cable entry: 2 x 1 /2 NPT. HM Cable entry: 2 x M16 & 1 x M20. HN Cable entry: 1 x M20. HO Cable entry: 2 x M20. HP Cable entry: 6 x M12. HT Cable entry: 1 x 1 /2 NPT. HU Cable entry: 3 x 1 /2 NPT. HV Cable entry: 4 x M20. HZ Cable entry: no holes. Digital output signals OA Three active transistor outputs requires PD, PF, PM or PX. OR Two mechanical relay outputs one OT requires PF or PM. OS Four mechanical relay outputs requires AP and PD. OT Three outputs standard configuration. Power requirements PD 8 24V AC / DC sensor supply with XI: 16 30V DC. PF 24V AC / DC sensor supply. PM V AC sensor supply. PX No power supply option. Additional battery supply (optional) PB Lithium battery powered requires PD or PX. PC Lithium battery powered Intrinsically Safe requires XI, and PD or PX. Hazardous area XI Intrinsically Safe, according ATEX and IECEx. XF Ex d enclosure 3 keys according ATEX. XX Safe area only. Other options ZB Backlight. ZX No options. The bold marked text contains the standard configuration. Available Intrinsically Safe. Specifications are subject to change without notice. Fluidwell bv P.O. Box AA Veghel The Netherlands Telephone: 31 (0) Telefax: 31 (0) displays@fluidwell.com Internet: 10 Copyright: Fluidwell bv 2017 F193DATAENV1727
VALVE POSITION INDICATOR
VALVE POSITION INDICATOR VPI FOR HYDRAULIC SYSTEMS DATASHEET F195 VALVE POSITION INDICATOR Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically
More informationLEVEL MONITOR DATASHEET F170 - LEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS
LEVEL MONITOR WITH ANALOG AND HIGH / LOW ALARM OUTPUTS DATASHEET F170 LEVEL MONITOR Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically Safe available
More informationDATASHEET F043 - TEMPERATURE MONITOR
TEMPERATURE MONITOR WITH ONE HIGH / LOW ALARM OUTPUT. DATASHEET F043 TEMPERATURE MONITOR Features Displays actual temperature and alarm values. Two alarm values can be entered: low and high temperature
More informationDATASHEET F111 - DUAL INPUT FLOW RATE / TOTALIZER
DUAL INPUT FLOW RATE / TOTALIZER WITH TWO PULSE SIGNAL OUTPUTS DATASHEET F111 DUAL INPUT FLOW RATE / TOTALIZER Features Displays for each flow the flow rate, total and accumulated total. Large 17mm (0.67")
More informationDIFFERENTIAL FLOW COMPUTER DATASHEET F127 - FLOWCOMPUTER WITH TEMPERATURE COMPENSATION FOR CORRECTED LIQUID VOLUME AND AND PULSE SIGNAL OUTPUTS
DIFFERENTIAL FLOW COMPUTER WITH TEMPERATURE COMPENSATION FOR CORRECTED LIQUID VOLUME AND AND PULSE SIGNAL OUTPUTS DATASHEET F127 FLOWCOMPUTER Advantages Robust IP67 (NEMA Type4X) field enclosure. It is
More informationDATASHEET F115 - BI-DIRECTIONAL FLOW RATE INDICATOR / TOTALIZER
DATASHEET F115 BIDIRECTIONAL FLOW RATE INDICATOR / TOTALIZER BIDIRECTIONAL FLOW RATE INDICATOR / TOTALIZER WITH ANALOG, PULSE SIGNAL AND FLOW DIRECTION OUTPUTS Features Ability to detect flow direction
More informationDATASHEET F111 - DUAL INPUT FLOW RATE / TOTALIZER
DUAL INPUT FLOW RATE / TOTALIZER WITH TWO PULSE SIGNAL OUTPUTS DATASHEET F111 DUAL INPUT FLOW RATE / TOTALIZER Features Displays for each flow the flow rate, total and accumulated total. Large 17mm (0.67")
More informationDATASHEET F116 FLOWCOMPUTER
DIFFERENTIAL / SUM FLOWCOMPUTER WITH ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F116 FLOWCOMPUTER Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically
More informationDATASHEET F074 - LEVEL / PUMP CONTROLLER
LEVEL / PUMP CONTROLLER WITH ONE CONTROL OUTPUT. DATASHEET F074 LEVEL / PUMP CONTROLLER Features Level control: high / low switch points and a preset value can be set. Displays actual level, switch points,
More informationFLOW RATE MONITOR / TOTALIZER
DATASHEET F118 FLOW RATE MONITOR WITH LINEARIZATION FLOW RATE MONITOR / TOTALIZER WITH LINEARIZATION, HIGH / LOW ALARMS AND ANALOG / PULSE SIGNAL OUTPUTS Advantages Robust IP66, IP67 (NEMA4X) field enclosure.
More informationDATASHEET F093 - TACHOMETER MONITOR
TACHOMETER MONITOR DISPLAYS ENGINE SPEED AND RUNNING HOURS WITH ALARM OUTPUT DATASHEET TACHOMETER MONITOR Advantages Robust IP66, IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it!
More informationDATASHEET F116 FLOWCOMPUTER
DIFFERENTIAL / SUM FLOWCOMPUTER WITH ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F116 FLOWCOMPUTER Features Calculates differential flow rate (consumption) total and accumulated total of flow A and B or
More informationDATASHEET F116 FLOWCOMPUTER
DIFFERENTIAL / SUM FLOWCOMPUTER WITH ANALOG AND PULSE SIGNAL OUTPUTS DATASHEET F116 FLOWCOMPUTER Features Calculates differential flow rate (consumption) total and accumulated total of flow A and B or
More informationDATASHEET F093 - TACHOMETER MONITOR
TACHOMETER MONITOR DISPLAYS ENGINE SPEED AND RUNNING HOURS WITH ALARM OUTPUT DATASHEET TACHOMETER MONITOR Advantages Robust IP67 (NEMA Type4X) field enclosure. It is so rugged, you can even stand on it!
More informationFLOWCOMPUTER WITH TEMPERATURE AND PRESSURE COMPENSATION FOR CORRECTED GAS VOLUME DATASHEET F126-EG - FLOWCOMPUTER
FLOWCOMPUTER WITH TEMPERATURE AND PRESSURE COMPENSATION FOR CORRECTED GAS VOLUME DATASHEET F126EG FLOWCOMPUTER Features Calculates compensated flow rate, total and accumulated total. Displays actual line
More informationDIFFERENTIAL FLOW COMPUTER
DIFFERENTIAL FLOW COMPUTER WITH TEMPERATURE COMPENSATION FOR CORRECTED LIQUID VOLUME DATASHEET F127 FLOWCOMPUTER Features Displays compensated consumption (flow rate), total and accumulated total. line:
More informationF112 Flow rate indicator / totalizer With linearisation and analog / pulse signal outputs
F112 Flow rate indicator / totalizer With linearisation and analog / pulse signal outputs Description The F112 provide very precise linearisation of the flow meters signal. In addition to the average K-factor
More informationPRESSURE MONITOR DATASHEET D053 - PRESSURE MONITOR WITH ONE HIGH / LOW ALARM OUTPUT.
PRESSURE MONITOR WITH ONE HIGH / LOW ALARM OUTPUT. DATASHEET D053 PRESSURE MONITOR DSeries advantages Unique, robust IP66, IP67 (NEMA Type4X) panel mount front enclosure made of die cast aluminum, allowing
More informationFLOW RATE INDICATOR / TOTALIZER DATASHEET F014 - FLOW RATE INDICATOR / TOTALIZER
FLOW RATE INDICATOR / TOTALIZER WITH PULSE SIGNAL OUTPUT DATASHEET F014 FLOW RATE INDICATOR / TOTALIZER Advantages Robust IP67 (NEMA4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically
More informationFLOW RATE INDICATOR / TOTALIZER WITH PULSE SIGNAL OUTPUT DATASHEET F014 - FLOW RATE INDICATOR / TOTALIZER
FLOW RATE INDICATOR / TOTALIZER WITH PULSE SIGNAL OUTPUT DATASHEET F014 FLOW RATE INDICATOR / TOTALIZER Features Displays instantaneous flow rate, total and accumulated total. Large 17mm (0.67") digit
More informationBATCH CONTROLLER DATASHEET F030 - BATCH CONTROLLER WITH ONE STAGE CONTROL. Signal output One control output for one-stage batching.
BATCH CONTROLLER WITH ONE STAGE CONTROL DATASHEET F030 BATCH CONTROLLER Features Large display shows preset value and running batch value simultaneously. Selflearning overrun correction. Easy operation
More informationBatch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs
Datasheet N410 User-friendly batch controller Reliable Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Advantages Save time and cost with the easy to
More informationDATASHEET F114 RATIO MONITOR / TOTALIZER
RTIO MONITOR / TOTLIZER WITH HIGH / LOW LRMS ND NLOG OUTPUT DTSHEET F114 RTIO MONITOR / TOTLIZER dvantages Robust IP67 (NEM4X) field enclosure. It is so rugged, you can even stand on it! Intrinsically
More informationPRODUCT CATALOG F-SERIES
PRODUCT CATALOG F-SERIES Indicators Totalizers Transmitters Flow Computers Batch Controllers Monitors Displays Flow Level Pressure Temperature FOR INTRODUCTION TO THE F-SERIES The F-Series range offers
More informationBatch Controller with numerical keypad and receipt printer driver
Datasheet N413 Batch Controller for ticket printing Reliable Batch Controller with numerical keypad and receipt printer driver Advantages Save time and cost with the easy to operate numerical keypad. Your
More informationBATCH CONTROLLER. Features. Input Options F130. DC powered with 7 yr battery or mains option. Overview
BATCH CONTROLLER F130 PRESET RESETTABLE TOTAL Features NON-RESET TOTAL PULSE OUTPUT > Displays Batch Total, Accumulated Total and Preset (+ New printer driver option) > Two stage valve control Or single
More informationFlow rate Indicator / Totalizer with linearization, analog and pulse signal outputs
Datasheet E112 Robust explosion proof indicator Reliable Flow rate Indicator / Totalizer with linearization, analog and pulse signal outputs Advantages Save time and gain flexibility with the easytooperate
More informationRATE / TOTALISER. Features. DC/Loop powered with 7 yr battery or mains option. Overview. Input Options. Outputs F110
RAT / TOTALISR Features F110 Shown with ABS field-mount back case RAT RSTTABL TOTAL > Displays Rate, Total and Accumulated Total > Rate to 3 decimal places / Total to 11 > 0-10KHz pulse input version /
More informationF130-P BATCH-CONTROLLER
F130-P BATCH-CONTROLLER Signal input flowmeter type P: pulse, Namur and coil. Status inputs: start and stop. Control output: two control outputs for two stage control, or one control output and pulse output
More informationBatch Controller. Owner s Manual Model F130-P. Signal input flowmeter type P: pulse, Namur and coil. Status inputs: start and stop
Batch Controller Owner s Manual Model F130-P Signal input flowmeter type P: pulse, Namur and coil Status inputs: start and stop Control output: two control outputs for two stage control, or one control
More informationEZ Batch III Batch--Controller
(909) 307-2295 www.gommci.com EZ Batch III Batch--Controller Signal input flowmeter type P: pulse, Namur and coil. Status inputs: start and stop. Control output: two control outputs for two stage control,
More informationF110-P FLOWRATE INDICATOR / TOTALIZER
F110-P FLOWRATE INDICATOR / TOTALIZER Signal input flowmeter: pulse, Namur and coil. Signal outputs: (0)4-20mA / 0-10V ref. flowrate and pulse ref. total. Options: Intrinsically Safe, Modbus communication,
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationF124-A. Ratio Controller. Signal input flow meters: (0)4-20mA. Control output: (0)4-20mA/ 0-10V. Alarm outputs: high / low ratio alarm
F124-A Ratio Controller Signal input flow meters: (0)4-20mA Control output: (0)4-20mA/ 0-10V Alarm outputs: high / low ratio alarm Options: Intrinsically Safe, Modbus communication and backlight F-Series
More informationtechnical datasheet technical datasheet MTL660 Displays Loop-powered indicators for hazardous areas
technical datasheet technical datasheet MTL0 Displays Loop-powered indicators for hazardous areas Loop powered -0mA Field and panel mounting Environmental protection to IP7 Easy to configure Number of
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationBA414DF Fieldbus indicator Single variable
FIELDBUS DISPLAYS BA4xx Series BA6xx Series Hazardous area Safe area NEW BA414DF indicator Single variable Shown with optional stainless legend plate Power Supply & Segment Coupler Host Intrinsically safe
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through
More informationOperating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015
Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in
More informationSensor boxes SRBC. Festo core product range Covers 80% of your automation tasks
Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity
More informationDigital Output Module 8-Channel Version for Zone 1 Series 9475/
www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationFlow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI
Overview The MAG 6000 I/6000 I Ex de is a microprocessorbased transmitter with a buildin alphanumeric display in several languages. The transmitters evaluate the signals from the associated electromagnetic
More informationNUFLO MC Series. Flow totalizers
NUFLO MC Series Flow totalizers Content NUFLO MC Series* Flow Totalizers Introduction................................................................................3 Comparison chart.........................................................................4
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationIndicators. Hazardous-Area Indicators. 830 X R Loop-Powered 16 Process Indicator. 830 X S1 Loop-Powered 16 Process Indicator
Hazardous-Area 830 X R Loop-Powered 16 830 X S1 Loop-Powered 16 830 X S2 Loop-Powered 16 15 Loop-Powered Digital 830 X Loop-Powered 830 X R 830 X S1 830 X S2 The 830 X loop-powered digital indicators are
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationDigital Output Module 8-Channel Version for Zone 2 Series 9475/
> 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in
More informationTUR012-P / F0..-P FLOWRATE INDICATOR / TOTALIZER
TUR012-P / F0..-P FLOWRATE INDICATOR / TOTALIZER Signal input flowmeter: coil. Options: Intrinsically Safe. Page 2 SAFETY INSTRUCTIONS Any responsibility is lapsed if the instructions and procedures as
More informationSYSTEM COMPONENTS SYSTEM COMPONENTS MODULES
SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES O U R P R O F E S S I O N MULTIFUNCTIONAL CURRENT CONTROLLED SWITCH MODULES MAIN FEATURES 4 20 ma input Relay output Rail mountable Intrinsically safe Associated
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationIsolating repeater IRU 420
Isolating repeater IRU 420 Universal intrinsically safe isolating repeater of current signals 0/4 20 ma with option voltage output 0 10 V For supply sensors with output 0/4 20 ma in Galvanic separation
More informationUFD 5. Display for ALTOSONIC 5. Technical Datasheet. Configurable display for ALTOSONIC 5 Easy installation Durable design
UFD 5 Technical Datasheet Display for ALTOSONIC 5 Configurable display for ALTOSONIC 5 Easy installation Durable design KROHNE 04/2015-0.00000.00.00 CONTENTS UFD 5 1 Product features 3 1.1 Local display
More informationTechnical Information Promonitor NRF560
TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationDigital Output Module 4-Channel Version for Zone 1 Series 9475/
www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >
More informationSensor boxes SRBE Key features and product range overview
Sensor boxes SRBE Sensor boxes SRBE Key features and product range overview Function Sensor boxes SRBE are used for electrical feedback and control of the position of process valves actuated using pneumatic
More informationTFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5
EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on
More informationTechnical Data. General specifications. Rated operating distance s n 3 mm
0102 Model Number Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection ATEX & IECEX certifications Usable up to SIL 2 acc. to IEC 61508 Weatherproof
More informationSafety instructions Overvoltage protection B81-35
Safety instructions Overvoltage protection B81-35 IECEx BVS 15.0084X Intrinsic safety Document ID: 51001 Contents 1 Area of applicability... 3 2 General information... 3 3 Technical data... 5 4 Application
More informationIntrinsically Safe Barriers
Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper
More informationStratos Pro A4 PH. Connection
For up-to-date information, please visit www.m4knick.com Stratos Pro A4 PH Connection Connection of PH module with any desired analog sensor or with ISM or ISFET sensors. Operation of Memosens sensors
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationSITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195
Overview MASS 6000 is based on the latest developments within digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against
More information7511 / / / 711 / / 731 / Preset 27
22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer
More informationGeneral Specifications
General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process
More informationLinear Luminaire with LED Series 6412/5
> For use in Zones 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationSupplementary Components WirelessHART products
Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
www.vaisala.com HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters Customers may specify the transmitter configuration when ordering the instrument, however changes in configuration
More informationT EN TROVIS Electropneumatic Positioner
T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.
More informationAssembly MAU. MUX 4 Channels 8 Channels Zone 1
Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.
More informationFlow Measurement SITRANS F US Clamp-on
Overview SITRANS FUG1010 clamp-on non-intrusive ultrasonic flow transmitter is ideal for natural and process gas applications, including checkmetering, allocation, production, storage and gas fired power
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G
More information4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F
4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationTermination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.
Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous
More information97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT
70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination
More informationFlow Measurement SITRANS F C
Overview MASS 6 is based on digital signal processing technology engineered for high performance, fast flow step response, fast batching applications, high immunity against process noise, easy to install,
More informationIHP24. Intelligent Hydraulic Positioner D HP- PL
IHP24 Intelligent Hydraulic Positioner D HP- PL- 0 0 3-01 IHP24 Intelligent Hydraulic Positioner Val Controls A/S Intelligent valve control based on the latest know-how concerning digital technology for
More informationTerminal Boxes Series 8118
> Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree
More informationPneumatic Control/Feedback
897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationF012-P FLOWRATE INDICATOR / TOTALIZER
F012-P FLOWRATE INDICATOR / TOTALIZER Signal input flowmeter: pulse, namur and coil. Page 1 SAFETY INSTRUCTIONS Any responsibility is lapsed if the instructions and procedures as described in this manual
More informationGrounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071
www.stahl.de > Monitored electrostatic grounding of tank containers and drums during loading > Continuous monitoring of correct grounding > Robust design > Weather-protected plastic enclosure (IP66) or
More informationSITRANS T measuring instruments for temperature
Overview for flexible and cost-effective temperature measurements Supports the standard (HART V 7.1) Very high security level for wireless data transmission Built-in local user interface (LUI) with -button
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More informationLevel gauges Series LS Level indicator, switch and transmitter for liquids
Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationFlow Measurement SITRANS F US Inline
Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication
More informationInductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position
More informationSFY Functional Safety Frequency-to-DC Transmitter with Display
Functional Safety -to-dc March 2017 Description The SFY Functional Safety SIL 3 capable -to-dc is part of Moore Industries FS Functional Safety Series. It monitors frequency, period, high or low pulse
More informationThe 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.
February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationPage 2. FL_F116P_v1702_01_EN
Page 1 Signal input flowmeter: pulse, Namur and coil Output: (0)4-20mA / 0-10V ref. flow rate, pulse ref. total and negative flow Options: Intrinsically safe, Modbus communication and backlight F-Series
More informationFlow Meters. Model B Flow Monitor. Model B2800. Flow Monitor
Flow Monitor Model B2800 Flow Meters Model B2800 Flow Monitor Microprocessor-based flow monitor and totalizer Use with Blancett turbine flow meters as well as other flow meters with a frequency output
More informationDräger Polytron 8200 Stationary gas detector (CatEx)
Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result
More informationSimplified information where and how you want it.
ConsolIdator 4 & 8 Multi-channel controllers Simplified information where and how you want it. ConsoliDator 4 Model PD940 ConsoliDator ConsoliDator 4 Features Four 4-20 Inputs Four 4-20 Outputs ConsoliDator
More informationExCos-P Pressure sensor 20 Pa Pa
ExCos-P Pressure sensor 20 Pa... 7.500 Pa Electrical, explosion-proof pressure / differential pressure sensors 24 VAC/DC supply voltage, 0...10 V / (0) analogue output EC type-approved in acc. with ATEX
More informationInductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 (Low Demand Mode) acc. to IEC 61508, PL c acc. to ISO 13849-1 at HFT0 SIL3 (All Demand Mode) acc. to IEC 61508, PL e acc. to ISO 13849-1
More information2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)
.3 Ex-Linear light fittings for fluorescent lamps ellk 9 18 W 58 W / ellm 9 18 W 36 W (Zone 1,, 1, ) The classic lighting solution in hazardous areas The ellk 9 linear luminaire series for fluorescent
More information