- Jason Wheeler
- 5 years ago
- Views:
Transcription
1 PBSCONTROL AMS-R4000 Modular RTU Remote Terminal Unit
2 AMS-R4000 Introduction The documentation and the software included with this product are copyrighted 2017 by pbscontrol Company. AMS-4000 System is common products between AMS and pbscontrol Companies. AMS is designed Hardware and it is powered by pbssoftlogic Kernel by pbscontrol Company. Disclaimer Information in this document is subject to change without notice and does not represent a commitment on the part of pbscontrol System. Technical Support Contact Information 2 AMS-R4000 Modular RTU
3 1.1. Overview The AMS-R4000 is a modular Remote Terminal Unit (RTU) based on the high performance Cortex-A8 1GHz ARM CPU with 512MB of RAM and 4GB of Flash. The device has an internal 3G/4G cellular modem, two 10/100 base-t Ethernet port, four serial communication ports and a wide range of hot swappable digital/analog input and output modules. Moreover, the AMS-R4000 RTU supports the EMC industry standard (IEC ), a -40 to 75 C operating temperature range, multiple communication protocols (Modbus, DNP3, IEC , OPC UA) and an IEC61131 based programming environment (PBS- SoftLogic). PBS-SoftLogic is an IDE for developing function block based programs, simulate and downloading to the RTU. You can use the C/C++ or Lua scripting language for developing new function blocks by yourself. By using these features, the AMS-R4000 RTU provides a comprehensive solution for data acquisition and control applications in the SCADA systems Package Checklist The AMS-R4000 and I/O Modules ships with the following items: AMS-R4000 (if ordered) AMS-R4000 CPU Module Software and Documentation CD-ROM Accessories Kit (Expansion connector, USB console cable, RJ45 Cable) Optional Accessories (3G/4G Cellular modem antenna) I/O Module (if ordered) AMS-R4XXX I/O Module Expansion connector 1.3. Available Products AMS-R4000 CPU Module AMS-R4116: 16 Channels Isolated Digital Input Module (4 Channels Counter) AMS-R4132: 32 Channels Isolated Digital Input Module AMS-R4216: 16 Channels Digital Output Module AMS-R4232: 32 Channels Digital Output Module AMS-R4312: 12 Channels Analog Input Module (16 Bit Resolution) AMS-R4324: 24 Channels Analog Input Module (16 Bit Resolution) AMS-R4404: 4 Channels Analog Output Module AMS-R4408: 8 Channels Analog Output Module AMS-R4504: 4 Channels Thermocouple Module (Type K, J, N, T, S, R, E) AMS-R4508: 8 Channels Thermocouple Module (Type K, J, N, T, S, R, E) AMS-R4604: 4 Channels RTD Module (PT100, PT1000) AMS-R4608: 8 Channels RTD Module (PT100, PT1000) 3 AMS-R4000 Modular RTU
4 AMS-R4701: Power Analyzer Module 1.4. Panel Guide 1.4. Product Specifications System CPU: Cortex-A8 based CPU, 32-bit/ 1GHz Instruction Execution Speed: 2000 MIPS RAM: 512MB Flash: 4 GB External Storage: Up to 32GB SD Card I/O Scan Time: 5 MS I/O Limit: Up to 1000 Signals Program Cycle Time: Adjustable (Minimum Time: 10 MS) Ethernet Interface LAN: Two 10/100 Mbps RJ45 ports Cellular Modem(GSM) Network: 2G/3G/4G Serial Interface Serial COM1, COM2: RS-232 (DB9 male) Serial COM3, COM4: RS485 Serial Signals RS-232: TxD, RxD, DTR, DSR, RTS, CTS, DCD, GND 4 AMS-R4000 Modular RTU
5 RS-485-2w: Data+, Data-, GND Power Requirements Input Voltage: 9 to 36 VDC CPU Module Power Consumption: o LP Mode (Modem OFF): 2~2.5 W o Data Mode: 4~5 W I/O Modules Power Consumption: 1~2 W Physical Characteristics Housing: Aluminum Mounting: DIN-Rail Dimensions: o CPU Module: 55 x 143 x 100 mm (2.16 x 5.63 x 3.94 in) o I/O Module: 38 x 143 x 100 mm (1.49 x 5.63 x 3.94 in) Environmental Limits Operating Temperature: -40 to 75 C (-40 to 167 F) Storage Temperature: -40 to 85 C (-40 to 185 F) Ambient Relative Humidity: 5 to 95% (non-condensing) Supported Protocols DNP3 Master/Slave IEC Master/Slave Modbus TCP Server/Client Modbus RTU Master/Slave OPC UA Server SQLite Database Engine FreeTDS Protocol Webserver Standards and Certifications Programming Standards o IEC Function Block Programming o LUA Programming Language o C/C++ Programing Language Tele Control Equipment Standards o IEC (Power supply and electromagnetic compatibility) o IEC (Interfaces - electrical characteristics) o IEC (Performance Requirements) EMC Standards: o IEC (Electrostatic Discharge) Level 2/3 o IEC (Radiated, Radio-Frequency, Electromagnetic Field) Level 2 o IEC (Electrical Fast Transients/Burst) Level 2 o IEC (Surge) Level 3 o IEC (Conducted Disturbances) Level 2 5 AMS-R4000 Modular RTU
6 Warranty o IEC (Power frequency magnetic field) Level 1 o IEC (Voltage Dips, Short Interruptions and Voltage Variations) o Note: Please check AlborzMicroSystem s website for the most up-to-date certification status. Warranty Period: 5 years Details: See www. AlborzMicroSystem.com/warranty 1.5. Physical Dimensions CPU Module Dimension (Unit : mm) 6 AMS-R4000 Modular RTU
7 IO Module Dimension (Unit : mm) 7 AMS-R4000 Modular RTU
8 1.6. LED Indicators CPU Module LED Groups LED (Color) Function Description System LED Ethernet LED (On the Plug) PWR (Green) RUN (Blue) ERR(Red) Net (Yellow) Eth1,2 (Yellow) Eth1,2 (Green) Light on, Device powered Blinking, Runtime Operation Blinking, Runtime Error Light on, Exception Error 200ms On/ 1800ms Off, Network searching 1800ms On/ 200ms Off, IDLE 180ms On/ 180ms Off, Data transferring Always On, Voice Call Always Off, Modem is turned off Light on, Link present Blinking, During activity Light on, 100Mbps Ethernet Serial LED T1,2,3,4 (Green) R1,2,3,4 (Red) Blinking, COM1,2,3,4 is sending data Blinking, COM1,2,3,4 is receiving data 8 AMS-R4000 Modular RTU
9 I/O Module All of the I/O module is equipped with a module status LED which is indicating the operation status as follow: LED Groups LED Color Function Description Module Status Off Blue Yellow Red Device not powered Blinking, Module Proper Operation Blinking, Module Warning Blinking, Module Error 9 AMS-R4000 Modular RTU
10 2.1. System Architecture The AMS-R4000 consists of a CPU module which is operates as the brain of the system. The CPU module manages the I/O module operation, collects their information and reports the processed information to the master of the SCADA system. The secure and reliable CAN protocol is used to communicate the CPU and I/O modules. This communication occurs through an expansion connector. CAN communication addresses for each I/O module are arranged dynamically by the CPU module. All communication failure of the I/O module during initialization and operation is detected by the CPU module and can be reported to the master of the SCADA system. 10 AMS-R4000 Modular RTU
11 2.2. Installing Modules on a DIN-Rail CPU Module In order to installing the CPU module on a DIN-Rail, simply perform the following steps: Insert the top of the DIN-Rail bracket into the top of the DIN-Rail. Rotate the top of the module downwards until the bracket snaps into the DIN-Rail. 11 AMS-R4000 Modular RTU
12 Move the module along the DIN-Rail until it is placed in the left side of the rail. I/O Modules In order to installing the I/O module on a DIN-Rail besides the other modules, simply perform the following steps: Insert the top of the DIN-Rail bracket into the top of the DIN-Rail. 12 AMS-R4000 Modular RTU
13 Rotate the top of the module downwards until the bracket snap into the DIN-Rail. Move the module along the DIN-Rail until it is placed next to the other module. 13 AMS-R4000 Modular RTU
14 If it is the first I/O module, use the AMS-R4001 expansion connector in order to communicate between the CPU and I/O module. 14 AMS-R4000 Modular RTU
15 If it is not the first I/O module, use AMS-R4002 expansion connector in order to communicate between I/O modules. After performing these steps, installation is completed. 15 AMS-R4000 Modular RTU
16 2.3. Removing Modules from a DIN-Rail In order to removing the CPU and I/O module from a DIN-Rail, simply perform the following steps: Remove the expansion connector between modules. Use a screwdriver in order to push down the spring-loaded part of the bracket. 16 AMS-R4000 Modular RTU
17 Rotate the bottom of the module upwards and then remove it from the DIN-Rail Connecting the Module Power The AMS-R4000 CPU module accepts power in the range of 9-36V DC. It should be noted that the I/O modules do not need the separate input power and the required power of these modules is provided by the CPU modules through the expansion connector. The required power of the system depends on the number of the I/O module and can be calculated as follow: Module CPU Module I/O Module Maximum Power Consumption 5 Watts 2 Watts It should be noted that the number of modules should be selected in such a way that the maximum input power of the system does not exceed than 100 Watts Connecting to the Network 17 AMS-R4000 Modular RTU
18 The AMS-R4000 CPU module supports two standard 10/100 Mbps Ethernet ports. Each port use a unique MAC address and supports Auto MDI/MDI-X mode, in which case the port s pinouts are adjusted automatically depending on the type of Ethernet cable used (straight-through or cross-over). The default configuration of the LAN2 Ethernet port is set as DHCP and the default configuration of the LAN1 LAN Port Default IP address Default Netmask Default Gateway LAN Programming Environment Ethernet port is set as static IP address as below: The PBS-SoftLogic programming environment is used to program the RTU which can be downloaded from After downloading the software, extract Zip file in a desired drive. Please note that the software folder path cannot be very long. Moreover, the software needs the Dot Net Frame Work for the proper operation. Open the software folder and run VSFBEditor.exe programming environment. Now, you can simply implement all your idea into your SCADA system. User manual of the software can be found in the doc folder of the software path Factory Defaults If the device network configuration was forgotten or the device booting failed due to the wrong user programming, simply perform the following steps in order to reset the device to the factory defaults: Disconnect the power supply of the device. Connect COM1 and COM2 RS232 serial ports of the RTU to each other by wire jumping TX1 to RX1 and RX2 to TX2. Connect the power supply. After finishing the booting process which takes about 30 second, the network configuration is reset to default network configuration and the last wrong user program is cleared. Disconnect the power supply of the device and then remove the wire jumping of the serial ports. Connect the power supply and use the device with the default network configuration. 18 AMS-R4000 Modular RTU
19 3.1. Digital Input Modules Overview The AMS-R4000 RTU provides two types of the digital input modules. The AMS-R4116 supports 16 channels of isolated digital inputs and the AMS-R4132 supports 32 channels of isolated digital inputs. To simplify field wiring, four inputs of these modules are building a group with a common return. The modules scan and process the inputs with the high time resolution of 5 ms. The measured value can be filtered by the CPU module with a software selectable filters such as the digital filter or chattering filter. The inputs of these modules are isolated by optocoupler and they are protected against transient voltages. Moreover, the modules is able to properly monitor the reverse polarity of the voltage input. The AMS-R4116 is equipped by four counter channel (Channel 1-4). The maximum permissible frequency for counter pulses is 120 Hz. The modules have 16 and 32 LEDs to indicate the signal state at the inputs. The required power of these modules are supplied by the expansion connector from the AMS-R4000 CPU module. Specifications AMS-R4116: 16 Channels Isolated Digital Input Module AMS-R4132: 32 Channels Isolated Digital Input Module Parameters Value Inputs per Module AMS-R4116: 16 Channels AMS-R4132: 32 Channels Input Type Dry contact (Sink) Counter per Module AMS-R4116 : 4 Channels (1-4) On-state Voltage 24 VDC Nominal, 12 VDC Minimum OFF-state Voltage 0 to 6 VDC, 6 VDC Maximum Maximum Input Voltage 30 VDC Transient Voltage Protection Yes Over Current Protection 200 ma per common Input Impedance 6K ohms Common Type 4 DI per COM Counter Frequency 120 Hz (Maximum) Response Time 5 ms Digital Filtering Software selectable (Digital and Chattering Filter) Isolation Optocoupler Isolation (3K VDC) 19 AMS-R4000 Modular RTU
20 Operating Temperature -40 to 85 C Power Consumption Maximum : 2 Watts Connector Pluggable type terminal block I/O Cable Wire AWG 18 (1.0 mm x mm) Maximum Wiring Diagram 20 AMS-R4000 Modular RTU
21 3.2. Digital Output Modules Overview The AMS-R4000 RTU provides two types of the transistor digital output modules. The AMS-R4216 supports 16 channels of transistor digital outputs and the AMS-R4232 supports 32 channels of transistor digital outputs. Using transistor instead of mechanical relay in these modules provide a fast performance and longer lifetime. The modules can be used to control relays, solenoid valves, panel lamps and other on/off devices which require DC voltage. Any failure of the modules is detected rapidly and the digital outputs are set to the safe values which can be specified by the software. The modules have 16 and 32 LEDs to indicate the signal state at the outputs. The required power of these modules are supplied by the expansion connector from the AMS-R4000 CPU module. Moreover, the modules require a 12 to 48 VDC power supply for the transistor biasing. Specifications AMS-R4216: 16 Channels Isolated Digital Output Module AMS-R4232: 32 Channels Isolated Digital Output Module Parameters Value Outputs per Module AMS-R4216: 16 Channels AMS-R4232: 32 Channels Output Impedance Less than 2 ohms Off-state Resistance 500K ohms Response Time 5 ms Transistor Biasing Voltage 12 to 48 VDC Over Voltage Protection 68 VDC Over Current Protection 400 ma (8 50 ma) Current Rating 50 ma per channel Isolation Optocoupler Isolation (3K VDC) Operating Temperature -40 to 75 C Power Consumption Maximum : 2 Watts Connector Pluggable type terminal block I/O Cable Wire AWG 18 (1.0 mm x mm) Maximum 21 AMS-R4000 Modular RTU
22 Wiring Diagram 22 AMS-R4000 Modular RTU
23 3.3. Analog Input Modules Overview The AMS-R4000 RTU provides two types of the analog input modules. The AMS-R4312 supports 12 channels of analog inputs and the AMS-R4324 supports 24 channels of analog inputs. The modules can be used to monitor level, flow, pressure, temperature and other analog transmitters. The modules is able to monitor and process wide range of the voltage signal in the range of 0 to 5 V, 0 to 10 V, -5 to +5 V and the current signal in the range of 0 to 20 ma, 4 to 20 ma. The measured differential values are converted in steps (16 bit resolution). The sampling rate of the module can be software selectable up to the 30 HZ. The modules have 12 and 24 LEDs to indicate the signal state at the inputs. The required power of these modules are supplied by the expansion connector from the AMS-R4000 CPU module. Specifications AMS-R4312: 12 Channels Analog Input Module AMS-R4324: 24 Channels Analog Input Module Parameters Value Inputs per Module AMS-R4312: 12 Channels AMS-R4324: 24 Channels Input Type Voltage, Current (Differential) Input Voltage Range 0 to 5 V, 0 to 10 V, -5 to +5 V Input Current Range 0 to 20 ma, 4 to 20 ma Input Impendence 120 ohms Resolution Range 16 bits Accuracy ±0.1% of FSR Sampling Rate Software selectable (Maximum 30 HZ) Operating Temperature -40 to 85 C Power Consumption Maximum : 2 Watts Connector Pluggable type terminal block I/O Cable Wire AWG 18 (1.0 mm x mm) Maximum 23 AMS-R4000 Modular RTU
24 Wiring Diagram 24 AMS-R4000 Modular RTU
25 3.4. Analog Output Modules Overview The AMS-R4000 RTU provides two types of the analog output modules. The AMS-R4404 supports 4 channels of analog outputs and the AMS-R4408 supports 8 channels of analog outputs. The modules can control valve actuators, motor speed controllers, temperature controllers or any device requiring an analog control signal. The modules is able to generate wide range of the voltage signal in the range of 0 to 5 V, 0 to 10 V, -5 to +5 V, -10 to +10 V and the current signal in the range of 0 to 20 ma, 4 to 20 ma by using the microprocessor-controlled D/A converter. Conversion range and slew rate of the modules can be specified by the software. The conversion resolution of the converter is 16 bits. Any failure of the modules is detected rapidly and the analog outputs are set to the safe values which can be specified by the software. The modules have 4 and 8 LEDs to indicate the signal state at the outputs. The required power of these modules are supplied by the expansion connector from the AMS-R4000 CPU module. Specifications AMS-R4404: 4 Channels Analog Output Module AMS-R4408: 8 Channels Analog Output Module Parameters Value Outputs per Module AMS-R4404: 4 Channels AMS-R4408: 8 Channels Output Type Voltage, Current Voltage Output Range 0 to 5 V, 0 to 10 V, -5 to +5 V, -10 to +10 V Current Output Range 0 to 20 ma, 4 to 20 ma Resolution in Ranges 16 bits Voltage Slew Rate to 64 V/sec Current Slew Rate to 128 ma/sec Output Impedance 100 ohms Maximum Conversion Time 1 ms for all channels Accuracy ±0.1% of FSR Operating Temperature -40 to 85 C Power Consumption Maximum : 2.5 Watts Connector Pluggable type terminal block I/O Cable Wire AWG 18 (1.0 mm x mm) Maximum 25 AMS-R4000 Modular RTU
26 Wiring Diagram 26 AMS-R4000 Modular RTU
27 3.5. Power Analyzer Modules Overview AMS-R4701 PWA is a 3 phase modular power analyzer for measuring and recording electrical parameters such as voltage, current, power factor, active, reactive and apparent powers, active and reactive energies in the electrical transmission and distribution lines. The measured data can be used to analyze the quality of the network, make corrections in the network, selecting compensators, reduce the losses and consumption management. The device is able to transfer the measuring parameters to a Modbus master device through the RS-485 serial port and the AMS bus. By using this feature, AMS-R4701 PWA can be communicate with 2 masters simultaneously. One of the masters is AMS-R4000 RTU CPU module and another can be standard Modbus RTU master devices with the RS485 communication. Specifications AMS-R4701: Power Analyzer Module Parameters Measuring Parameters Measurement Updating Time Voltage Input Range Current input Range Capability to Measure with 2 PTs Capability to Measure with 2 CTs Accuracy Frequency Display Data Recording Capability Recording Period Auxiliary supply Communication Environmental Value - Line and Phase Voltages - Phase and Neutral Currents - Phase and Total of the Active, Reactive and Apparent Powers - Active and Reactive Energy - Phase Power Factor - Frequency True RMS 100 ms 80 to 400 VAC L-L 50 ma to 5A Yes Yes 1.0% of the reading value 45 to 65 Hz TFT LCD Yes Software selectable (from 1 min to 1 hour) 85~280 VAC MODBUS RTU Protocol through RS485 serial port and AMS Bus Operating temperature: -10 C to 60 C Storage temperature: -25 C to +70 C 27 AMS-R4000 Modular RTU
28 Standards Humidity 5% to 95% non condensing IEC IEC Day light saving option Measure and store temperature Software calibration Isolated current and voltage measurement Graphical software for power consumption management 28 AMS-R4000 Modular RTU
29 Wiring Diagram *Vs pin is Vsupply, it can be powerd with 85~280vac from Vn or tied to phase 1, 2 or 3. Menu and Panel Description: AMS-R4701 is able to show all the measuring parameters on the display panel. Moreover, users can change device configuration with setting pages. At the main menu, there are 13 pages. Pages 1 to 10 show the measured values, page 11 for the date and time, page 12 for device setting parameters and last page for communication status monitoring. First page show the measured values of the phase voltages from phase 1 to 3 as shown below: 29 AMS-R4000 Modular RTU
30 Press up or down button to navigate in the pages. Press Enter button to see the parameter type of the shown value. Press Enter button to see the parameter type of the shown value. 30 AMS-R4000 Modular RTU
31 By reusing the up or down button, you can switch between other pages which shown the line voltages, active, reactive and apparent power, active, reactive and apparent energy, power factor and frequency as shown below: 31 AMS-R4000 Modular RTU
32 Main Menu Page 11: Date and Time In this page, time, date and calendar are shown. Press Enter to change time zone or calendar type. Main Menu Page 12: Setting In this page, default setting of the device can be changed by the user. By pressing enter button, user should type password to open setting menu. If user type a wrong password for 3 times, device will be locked for 10 min. After this time period, if user do it again, the device will be locked and need a factory code to unlock. 32 AMS-R4000 Modular RTU Main Menu Page 13: Communication Status This page monitor send and receive data packet through the AMS-Bus or the Modbus communication. Port1 show the communication status through the Modbus RTU over serial RS485 and Port2 show the communication status through AMS Bus with AMS- R4000 RTU. If the request and respond packet exceed than 9999 packets, the counter will be reset.
iopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission
iopac 8020 Series Rugged modular RTU controllers Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications Supports C/C++ programming languages 2-port Ethernet switch for daisy-chain
More informationiologik E1200H Series
iologik E1200H Series Ethernet remote I/O for offshore wind power applications Features and Benefits User-definable Modbus TCP Slave addressing 2-port Ethernet switch for daisy-chain topologies Active
More informationiopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature
Programmable Controllers iopac 8500 Series Award-winning Product Rugged modular RTU controllers Dedicated ARM (RISC) CPUs for the main system and each I/O module Millisecond timestamp granularity for digital
More informationiopac 8020 Series Rugged modular RTU controllers Overview Programmable RTU Controllers Ethernet bypass feature for seamless data transmission
iopac 8020 Series Rugged modular RTU controllers Compliant with EN 50121-3-2, EN 50121-4, and a portion of EN 50155 specifications Supports C/C++ programming languages 2-port Ethernet switch for daisy-chain
More informationFeatures. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System
Features 10/100Mbps Ethernet full duplex Auto Negotiation Support C++/C Modbus/TCP drivers and OPC server Support configuration via built-in Web browsing, (HTML), Device Finder and I/O configuration utilities
More informationArm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications
IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk
More informationMGate 5111 Quick Installation Guide
MGate 5111 Quick Installation Guide Edition 1.0, December 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationArm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. Certifications
UC-7100 Series Arm-based palm-sized industrial computers with 2 serial ports and 2 LAN ports Features and Benefits MOXA ART Arm9 32-bit 192 MHz processor 16 or 32 MB RAM 8 or 16 MB Flash ROM Dual or single
More informationINGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016
ZY8932IMA01E 31/03/2016 INGEPAC DA-CU Control Unit Data Sheet Total or partial reproduction of this publication by any means or procedure is prohibited without previous express written authorisation by
More informationFeature and Benefits. Certifications
UC-2100 Series Arm-based palm-sized industrial computing platform for IIoT applications Feature and Benefits Armv7 Cortex-A8 1000 MHz processor 1 or 2 auto-sensing 10/100 Mbps Ethernet ports Gigabit Ethernet
More informationTM221M16TG controller M IO transistor PNP spring
Characteristics controller M221 16 IO transistor PNP spring Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete
More informationModbus TCP/RTU Gateway
Modbus TCP/RTU Gateway Hardware Installation Guide for models IE-GW-MB-2TX-1RS232/485 IE-GWT-MB-2TX-1RS232/485 Second Edition, June 2014 1516600000/01/06.14 Important note: The detailed user manual, additional
More informationArm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.
UC-8100 Series Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports Features and Benefits Armv7 Cortex-A8 300/600/1000 processor Dual auto-sensing 10/100 Mbps Ethernet
More informationMGate MB3170/MB3270 Quick Installation Guide
MGate MB3170/MB3270 Quick Installation Guide Edition 7.1, February 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationSerial/Ethernet Converter
Serial/Ethernet Converter IE-CS-2TX-1RS232/485 IE-CST-2TX-1RS232/485 IE-CS-2TX-2RS232/485 IE-CST-2TX-2RS232/485 Hardware Installation Guide Second Edition, August 2016 1243440000/01/08.16 Please note:
More informationTM221ME32TK controller M IO transistor PNP Ethernet
Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current
More informationFeatures and Benefits. Certifications
iologik E2200 Series Smart Ethernet remote I/O with Click&Go Logic Features and Benefits Front-end intelligence with patented Click&Go control logic, up to 24 rules Active communication with MX-AOPC UA
More informationMGate 5118 Quick Installation Guide
MGate 5118 Quick Installation Guide Edition 1.0, December 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationTM221M16R controller M IO relay
Product data sheet Characteristics TM221M16R controller M221 16 IO relay Complementary Main Discrete I/O number 16 Number of I/O expansion module Supply voltage limits Inrush current Power consumption
More informationTM221CE24R controller M IO relay Ethernet
Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush
More informationFeatures and Benefits. Certifications
iologik R1200 Series RS-485 remote I/O Features and Benefits Dual RS-485 remote I/O with built-in repeater Supports the installation of multidrop communications parameters Install communications parameters
More informationTM221M32TK controller M IO transistor PNP
Characteristics controller M221 32 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete
More informationOnCell G3100 Series Quick Installation Guide
OnCell G3100 Series Quick Installation Guide Edition 4.1, August 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationTM221CE40T controller M IO transistor PNP Ethernet
Product data sheet Characteristics TM221CE40T controller M221 40 IO transistor PNP Ethernet Complementary Main Discrete I/O number 40 Number of I/O expansion module Supply voltage limits Inrush current
More informationTM241CEC24R controller M IO relay Ethernet CAN master
Characteristics controller M241 24 IO relay Ethernet CAN master Main Range of product Product or component type [Us] rated supply voltage Nov 28, 2017 Modicon M241 Logic controller 100...240 V AC Discrete
More informationiologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Active communication with patented MX-AOPC UA Server and Active OPC Server 2 switched Ethernet ports for daisy-chain topologies Easy
More informationMGate 5105-MB-EIP Series
MGate 5105-MB-EIP Series 1-port Modbus RTU/ASCII/TCP-to-EtherNet/IP gateways Features and Benefits Protocol conversion between Modbus and EtherNet/IP Supports EtherNet/IP Scanner/Adapter Supports Modbus
More informationTM221CE40R controller M IO relay Ethernet
Characteristics controller M221 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Jan 6, 2019 Modicon M221 Logic controller 100...240 V AC Discrete input number
More informationTM221ME16T controller M IO transistor PNP Ethernet
Characteristics controller M221 16 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type
More informationVL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.
A configurable industrial computer platform Intel Atom Z0PT CMAT IPC Module Option [I8] AUTOMATION Data Sheet 90_en_A Description PHOENIX CONTACT 0-0-0 Features The VL BPC MINI is an embedded box PC and
More informationVL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features
A configurable industrial computer platform Data sheet 90_en_F Description PHOENIX CONTACT 0-08- Features The VL BPC MINI is an embedded box PC and is part of the Valueline family of industrial computers.
More informationiothinx 4500 Series (45MR) Modules
iothinx 4500 Series (45MR) Modules Modules for iothinx 4500 Series Feature and Benefits Easy tool-free installation and removal Built-in LED indicators for IO channels Wide operating temperature range:
More informationFeatures and Benefits. Certifications
UC-5100 Series Arm-based Industrial computing platform for industrial automation Features and Benefits Armv7 Cortex-A8 1000 MHz processor Dual auto-sensing 10/100 Mbps Ethernet ports 4 software-selectable
More informationTM221CE24T controller M IO transistor PNP Ethernet
Characteristics controller M221 24 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type
More informationiologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Introduction Remote I/O PC-Free Alarm and Control Intelligence
iologik E2200 Series Smart Ethernet remote I/O with Click&GO Logic Active communication with patented MX-AOPC UA Server and Active OPC server Smart alarm management with email, SNMP traps, TCP, UDP Save
More informationICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions
ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter
More informationOnRISC. OnRISC Baltos ir 2110
OnRISC OnRISC Baltos ir 2110 Hardware Manual Edition: October 2015 Tel: +49 40 528 401 0 Fax: +49 40 528 401 99 Web: www.visionsystems.de Support: service@visionsystems.de The software described in this
More informationDIN Rail RTU 540CMD01 Data sheet
RTU540 product line DIN Rail RTU 540CMD01 Data sheet 4 3 RS232C RS232C RS232C or RS485 or RS485 or RS485 1 2 E1 E2 10/100 MB LAN Protocol Protocol Controller Controller MPU Cortex-A8 AM3352 Application
More informationTM241CE24T controller M IO transistor PNP Ethernet
Characteristics controller M241 24 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Apr 10, 2018 Modicon M241 Logic controller 24 V DC Discrete input
More informationTM241CE40T controller M IO transistor PNP Ethernet
Characteristics controller M241 40 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage 18 Nov, 2018 Modicon M241 Logic controller 24 V DC Discrete input
More informationMGate 4101-MB-PBS Series
MGate 4101-MB-PBS Series 1-port Modbus RTU/ASCII-to-PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus and PROFIBUS Supports PROFIBUS DP V0 slave Supports Modbus RTU/ASCII
More informationMatrix-710. Linux-Ready Cortex-A5 Industry IoT Gateway. Hardware Guide. Version: Nov.
Matrix-710 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide Version: 1.01 2017 Nov. Copyright Artila Electronics Co., Ltd. All Rights Reserved Trademarks The Artila logo is a registered trademark
More informationUC-8410A Quick Installation Guide
UC-8410A Quick Installation Guide Edition 1.0, May 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778 Moxa
More informationTM241CE40R controller M IO relay Ethernet
Characteristics controller M241 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Apr 10, 2018 Modicon M241 Logic controller 100...240 V AC Discrete input number
More informationMotortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision
Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision 1.03.00 Motortronics / Phasetronics 1600 Sunshine Drive Clearwater, Florida 33765 Tel: 727-573-1819 Fax: 727-573-1803
More informationiologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch Introduction Remote I/O Daisy-Chained Ethernet I/O Connection
iologik E1200 Series Ethernet remote I/O with 2-port Ethernet switch User-definable Modbus/TCP Slave addressing Supports EtherNet/IP* adapter mode Supports RESTful API for IIoT applications 2-port Ethernet
More informationTM241CE24U controller M IO transistor NPN Ethernet
Characteristics controller M241 24 IO transistor NPN Ethernet Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 24 V DC Discrete input
More informationIDS-141A/181A. Industrial 4-port/8-port slim type serial to Ethernet device server. Features. Introduction. DS-Tool
4/8 Port v1.5 / Dec, 2011 Features 4-port/8-port slim type serial to Ethernet device server Operating Modes : Virtual Com, Tunnel, TCP Server, TCP Client, UDP Multiple host devices : 5 host devices: Virtual
More informationTM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.
Product datasheet Characteristics TM241CEC24T Main Range of product Product or component type [Us] rated supply voltage Discrete input number Discrete output type Discrete output number Discrete output
More informationInstallation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)
Package Contents Before installing your R3000 Lite Router, please verify the kit contents as following. 1 x Robustel R3000 Lite Industrial Dual SIM Cellular VPN Router 1 x 3-pin pluggable terminal block
More informationTM241C40U controller M IO transistor NPN
Characteristics controller M241 40 IO transistor NPN Main Range of product Product or component type [Us] rated supply voltage 15/12/2018 Modicon M241 Logic controller 24 V DC Discrete input number 24
More informationEX KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection)
EX-1331-4KVIS RS232/422/485 3-in-1 Serial to USB Adapter (w/ 4KV Isolation, 15KV ESD Surge Protection) 1. Introduction Thank you for purchasing this RS232/422/485 3-in-1 Serial to USB Adapter. It is an
More informationTM241CE24T controller M IO transistor PNP Ethernet
Characteristics controller M241 24 IO transistor PNP Ethernet Product availability : Stock - Normally stocked in distribution facility Price* : 479.00 USD Main Range of product Product or component type
More informationVL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features
Valueline configurable box PC Data sheet 0_en_E Description PHOENIX CONTACT 0-07- Features The VL BPC 000 is a configurable box PC that can be mounted either directly on a wall or on a DIN rail. The VL
More informationFeatures and Benefits. User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors.
NPort 5400 Series 4-port RS-232/422/485 serial device servers Features and Benefits User-friendly LCD panel for easy installation Adjustable termination and pull high/low resistors Socket modes: TCP server,
More informationTM241C24T controller M IO transistor PNP
Characteristics controller M241 24 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Feb 13, 2018 Modicon M241 Logic controller 24 V DC Discrete input number 14
More informationNPort 5200 Series Quick Installation Guide
NPort 5200 Series Quick Installation Guide Edition 8.0, February 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationiologik E4200 Modular Active Ethernet I/O adaptor IT and Instrumentation for industry Introduction Specifications LAN Regulatory Approvals Warranty
ioogik E4200 Modular Active Ethernet I/O adaptor Supports up to 16 I/O modules Dual Ethernet ANs and one RS-232 port Front-end intelligence that supports 80 Click&Go rules Unicode Active Messaging with
More informationiologik 4000 Series Modular remote I/O Introduction iologik E4200 Specifications Remote I/O Slice Form Factor and Flexible I/O Variety
iologik 4000 Series Modular remote I/O I/O expansion without a backplane Supports SNMPv1/v2c Active communications with MX-AOPC UA Server Easy configuration with Modular ioadmin utility Friendly configuration
More informationNPort S8000 Series Quick Installation Guide
NPort S8000 Series Quick Installation Guide Edition 6.0, March 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationTM241CE24T controller M IO transistor PNP Ethernet
Product data sheet Characteristics TM241CE24T controller M241 24 IO transistor PNP Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Inrush current
More informationPart No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version
Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring
More informationI-7520: RS-232 to RS-485. Input: RS-232 protocol Output:RS-485/RS-422 Speed: Self Tuner 'inside, auto switching baud rate, 300~ BPS
I-7520 RS-232 to RS-485 Converter I-7510 RS-485 Repeater RS-232 RS-485 I-7000 SERIES Common Specifications Isolation voltage: 3000VDC Speed: 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115000 Dual watchdog
More informationTM241CE40R controller M IO relay Ethernet
Characteristics controller M241 40 IO relay Ethernet Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 100...240 V AC Discrete input number
More informationD7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES
11/17 D7000 SERIES MODBUS TCP/IP ETHERNET INTERFACE MODULES D7000 FEATURES Complete data acquisition systems. Analog and Digital I/O models available. RJ-45 Ethernet 10/100MB interface. Modbus TCP/IP Ethernet
More informationNPort W2150A/W2250A Series Quick Installation Guide
NPort W2150A/W2250A Series Quick Installation Guide Edition 6.1, September 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax:
More informationFeatures and Benefits. Certifications
iopac 8600 Series Rugged modular programmable controllers Features and Benefits Modular CPU/power/backplane design that supports 85M/86M modules Tag-centric design with ready-to-run services Supports C/C++
More informationUSER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)
USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...
More informationApplication. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks. The MPU handles the absolute time and
More informationFeatures. Preliminary. Industrial IEEE b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway. Introduction
IMG-4312-MN Industrial IEEE 802.11 b/g/n with 2x10/100Base-T(X) 1x RS-232/422/485 IoT LTE LPWAN Gateway Features Provide 2x10/100Base-T(x) port and single SIM card slot LTE CAT-M1/CAT-NB1 model included
More informationNPort 5100 Series Quick Installation Guide
NPort 5100 Series Quick Installation Guide Edition 4.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationControl Panel CP600-eCo CP604, CP604-B
DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active
More informationTM241CE40R controller M IO relay Ethernet
Characteristics controller M241 40 IO relay Ethernet Product availability : Stock - Normally stocked in distribution facility Price* : 559.00 USD Main Range of product Product or component type [Us] rated
More informationUser Manual A08. User Manual
A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...
More informationNPort 6600 Series Quick Installation Guide
NPort 6600 Series Quick Installation Guide Edition 10.0, November 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More information256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client
User Manual V1.0.0 Table of Contents Overview... 1 1.1. Specification... 1 1.2. Dimensions... 2 1.3. Connector pinouts... 3 1.4. Restoring factory default... 3 1.5. LED indicator... 3 1.6. CR1225 battery...
More informationMGate 5105-MB-EIP Quick Installation Guide
MGate 5105-MB-EIP Quick Installation Guide Edition 2.2, March 2019 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationDeviceMaster RTS 16-Port Hardware Installation
DeviceMaster RTS -Port Hardware Installation Red underscored text link to Internet URLs. Blue underscored text link to sections within this document or to another document in the library. Note: If you
More informationFeatures and Benefits. Certifications
MGate 5111 Series 1-port Modbus/PROFINET/EtherNet/IP to PROFIBUS slave gateways Features and Benefits Protocol conversion between Modbus, PROFINET, EtherNet/IP, and PROFIBUS Supports PROFIBUS DP V0 slave
More informationTM241C40R controller M IO relay
Characteristics controller M241 40 IO relay Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 100...240 V AC Discrete input number 24
More informationRedundant System Redundant System P9-1-1
.. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
More informationNPort 5400 Series Quick Installation Guide
NPort 5400 Series Quick Installation Guide Edition 7.0, November 2015 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777 Fax: 1-714-528-6778
More informationTRP-C37 User s Manual
TRP-C37 User s Manual Ethernet to RS232/422/485 Converter Printed Oct. 2010 Rev 1.0 Trycom Technology Co., Ltd 1F, No.2-11, Sihu street, Yingge Township, Taipei, Taiwan ROC Tel: 886-2-86781191, Fax: 886-2-86781172
More informationIndustrial Serial Device Server
1. Quick Start Guide This quick start guide describes how to install and use the Industrial Serial Device Server. Capable of operating at temperature extremes of -10 C to +60 C, this is the Serial Device
More informationOperation Manual of EX9132CST-Series
Operation of EX9132CST-Series Serial to TCP/IP Converter (EX9132CST-2/ EX9132CST-RS485/ EX9132C-RS232) Version 1.0.0. 30.03.2017 Table of Contents 1 Introduction... 4 2 Overview... 5 2. 1 Package Checklist...
More informationTM241CE40R controller M IO relay Ethernet
Product data sheet Characteristics TM241CE40R controller M241 40 IO relay Ethernet Complementary Main Discrete I/O number 40 Discrete input logic Discrete input voltage Discrete input voltage type Voltage
More informationTM221ME16T controller M IO transistor PNP Ethernet
Product datasheet Characteristics TM221ME16T controller M221 16 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Modicon M221 Logic controller 24 V DC
More informationTF501, TF521 Terminal Bases
Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,
More informationTRP-C37. Ethernet to RS232/422/485 Converter. User s Manual. Printed Apr.2014 Rev 1.3
TRP-C37 Ethernet to RS232/422/485 Converter User s Manual Printed Apr.2014 Rev 1.3 Trycom Technology Co.,Ltd No.35, Zhongxing Rd., Guishan Township, Taoyuan County 333, Taiwan. Tel : 886-3-350-3351 Fax:
More informationDA-820 Series Quick Installation Guide
DA-820 Series Quick Installation Guide x86 Rackmount Embedded Computers Edition 2.0, January 2018 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel:
More informationLantech LSC-1102B SERIAL TO TCPIP CONVERTER. User Manual
Lantech LSC-1102B SERIAL TO TCPIP CONVERTER User Manual V1.0 Sep 2016 Table of Contents 1. Introduction 3 Overview 4 Product Specifications 8 2. Description & Installation 10 Product Panel Views 10 LED
More informationRTU560 Connections and Settings DIN Rail RTU 560CIG10
Connections and Settings DIN Rail RTU 560CIG10 Application, characteristics and technical data have to be taken from the hardware data sheet: 560CIG10 1KGT 150 719 Operation The 560CIG10 is a DIN rail
More informationFeatures and Benefits. SNMP MIB-II for network management. Certifications
NPort 5600-DT Series 8-port RS-232/422/485 serial device servers Features and Benefits 8 serial ports supporting RS-232/422/485 Compact desktop design 10/100M auto-sensing Ethernet Easy IP address configuration
More informationInstallation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)
Package Contents Before installing your R3000 Quad Router, please verify the kit contents as following. 1 x Robustel GoRugged R3000 Quad Industrial Dual SIM Cellular VPN Router with 4 Ethernet Ports 1
More informationMoxa TCC-100 Series User s Guide
Moxa TCC-100 Series User s Guide Eighth Edition, February 2009 www.moxa.com/product 2009 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. Moxa TCC-100 Series User s Guide The
More informationNI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server
DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400
More informationRAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description
I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules
More informationApplication. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11
Data Sheet Communication Unit 560CMD11 Communication Unit 560CMD11 The SLC works as master for the RTU560 serial peripheral bus (I/O-Interface/ Wired-OR-Bus ). The MPU is responsible for the other tasks.
More informationControl Panel CP600 CP651, CP651-WEB
DATA SHEET Control Panel CP600 CP651, CP651-WEB 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP551100R0001 CP651, control panel, TFT graphical display, single-touch screen, 10.4, Active
More informationMatrix-700 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide
Matrix-700 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide Version: 1.12 2018 Jan. Copyright Artila Electronics Co., Ltd. All Rights Reserved. Matrix-700 Hardware Guide Trademarks The Artila
More information