Central monitoring of self-contained luminaires Eaton, All Rights Reserved.

Size: px
Start display at page:

Download "Central monitoring of self-contained luminaires Eaton, All Rights Reserved."

Transcription

1 Central monitoring of self-contained luminaires

2 Categories for self-contained luminaires "Unmonitored" luminaires Only the battery charge circuit is tested if voltage exists green LED lights up Manual tests and inspection book management Luminaires with automatic test - AT The battery and light source circuit (LED) is continuously monitored and the status displayed via LED Automatic start of specified tests Weekly function test Annual duration test Manual inspection book management Centrally monitored luminaires: CGLine+ system Luminaire monitoring and automatic tests: see AT Central display of system status Automatic inspection book management with digital memory Web access and visualization possible with CGVision 2

3 Self-contained luminaire System CGLine+ Simply the most flexible, reliable monitoring for peace of mind 3

4 Installation, commissioning, operation

5 CGLine+ Web-Controller: Installation Up to 800 luminaires per CGLine+ Web-Controller 4 lines with up to 200 luminaires (or 2 lines with up to 400 luminaires) No manual addressing (distinctive ID per luminaire) Automatic luminaire detection Easy assignment due to free short address assignment Individual name for each luminaire Line 4 Line 3 Line 2 Line ID: A0 08 F0 ID: C0 0E A2 ID: EF A0 3D ID: 46 FC A ID: DC 57 FA ID: BE EC 7B ID: 2F 24 BC ID: ED 3C 8B ID: EE F8 CD ID: 9F F0 FC ID: 0F ED 2F ID: CD 4F 7A ID: 4F E7 44 ID: F6 45 AB ID: 7D BD 1C ID: 1C D0 EF 5

6 800 Luminaires per Controller 4 lines with up to 200 luminaires per line Line Line 2 Line 3 Line or 2 lines with up to 400 luminaires per line Line Line

7 Distinctive ID per luminaire Addressing of CGLine+ luminaires Distinctive Address, six characters ID-Number in HEX-Code No manual addressing Numeric short address free programmable for each luminaire Individual name (20 characters) for each luminaire ID A008F0 C00EA2 EFA03D F645AB 46FCA8 ED3C8B Line 1 Short digital address Individual name Exit 1st floor north Hall 1st floor front Hall 1st floor, mid1 Hall 1st floor, mid2 Hall 1st floor, back Exit 1st floor south 7

8 Web-Server Safety under control worldwide An integrated web server is available for convenient visualization, control and monitoring of all connected CGLine+ luminaires. From any PC with an IP connection and a regular web browser Without requiring any special software Line 1 Line 2 Line 3 Line IP connection 8

9 Overview Zones Maintain an overview: Allocate the luminaires to zones Up to 8 zones per line with 4 lines / 16 zones per line with max. of 2 lines Zone 1 Zone 2 Zone 3 Line Line

10 Zone segmentation 4 lines with up to 200 luminaires per line Number of lines No. of zones / line Numbering zones 2 lines with up to 400 luminaires per line Max. no. luminaires per zone Numbering luminaires Total number of luminaires Number of lines No. of zones / line Numbering zones Max. no. luminaires per zone Numbering luminaires Total number of luminaires

11 Automatic Test Never forgetting a test Automatic function test and duration test of luminaires Testing at the right time Up to 8 different test groups for FT and DT Test group Test group 2 11

12 Electronic Log book Electronic log book saves the need for manual logging Electronic inspection book for automatic saving of results from function and duration tests Stored for at least four years, in compliance with standards Downloadable in TXT or DAT file format DAT file can be transported using a regular USB stick Efficient and convenient analysis of the log book using the CGLine+ PC software or 12

13 Automatic dispatch Always informed Automatic dispatch if faults occur Assignable events 2 recipient groups to implement hierarchical escalation Acknowledgment function Line Line 2 Line 3 Line Integrated function IP connection 13

14 Control commands per luminaire Selective assignment commends Blocking / Release Manual start or stopping of a Function- or Duration test Switch off / on of maintained mode luminaires All luminaires, per line, per zone or per single luminaire 14

15 Floor layouts Maintaining orientation in complex buildings Luminaires visualised in up to 30 different floor layouts (across lines) 15

16 PC-Software Compatibility with the CGLine 400 System Extended CGLine+ functions only with unmixed CGLine+ luminaires Operation in CGLine 400 compatibility mode with CGLine 400 luminaires CGLine+ CGLine 400 luminaires luminaires CGLine+ Controller CGLine+ mode CGLine 400 mode CGLine 400 Controller CGLine 400 mode CGLine 400 mode Configuration with PC-Software Short address and individual name per luminaire Zone assignment of luminaires Defining of test groups Entire system can be configured in offline mode regardless of whether the IT network is available Line 1 Line 2 Line 3 Line 4 USB connection

17 CGLine+ data line 2 wires are sufficient Cross-section according to cable lengths No shielding required Cable length per line (400 luminaires) Crosssection Length 0.5 mm m 1320 m 1.0 mm m 2640 m With 4 lines in total 1.5 mm m 4000 m Free topology Cabling can be with star, tree or line configurations Robust against faults No shielding required Data per line Supply voltage on bus Max. permissible voltage drop Bus current 25 V DC 14 V 400 ma 17

18 Overview CGLine+ System LAN LAN LAN LAN LAN 18

19 Overview CGLine+ System CGLine+ Web-Controller: With integrated memory for storing the configuration and the log book IP connection Integrated function USB stick: To conveniently assess the log book on the PC Visualization of up to 800 luminaires (4 lines with max. 200 lights each or 2 lines with max. 400 lights each, in case of nonmixed installation of CGLine+ lights) PC connected to the network or an optional CGLine+ Wireless Monitoring Set: Access using the integrated web interface CGLine+ PC-Software for configuration Printer: Printing out the log book 19

20 Hardware, Software

21 CGLine+ Web-Controller 4 USB-1 host for connecting a USB stick USB-2 device for connection to PC 6 PE/L/N 230V 50/60Hz 7 Connection CGLine+ bus line RS LAN (RJ45) with LED displays: Yellow = Link Green = Traffic 1 LED displays Line 1 to Line 4 signalizes transmission to the CGLine+ lines: Green = receive; Yellow = send 2 Status LED display of the device: Power (green) = mains power O.K. Test (yellow/green) = FT/DT indication Failure (red) = sum failure 3 Push button: service = e.g. starting a FT System = establish a USB connection on USB2 10 S1/S2 = Block input In1, In2 = 2 x digital inputs 11, 12, 14, 21, 22, 24 = 2 x relay outputs 21

22 CGLine+ Web-Controller 22

23 CGLine+ Software: Starting screen 23

24 CGLine+ Software: Failure indication 24

25 CGLine+ Software: Failures per zone 25

26 CGLine+ Software: Overview luminaires 26

27 CGLine+ Software: Commands 27

28 CGLine+ Software: Test groups 28

29 CGLine+ Software: function 29

30 CGLine+ Software: Log book 30

31 CGLine+ Software: Layout 31

32 CGLine+ Wireless Monitoring Set Mobile monitoring Wireless visualization of up to 800 CGLine+ self-contained luminaires no wired network connection close to the luminaire required Accessing detailed information of every luminaire regardless of its installed location Function test can be started on site to directly check that the luminaire is operative Location-independent access to the electronic workbook Integrated WiFi access point Convenient operation via a web browser and touchscreen Apple ipad Air, 32 GB, WiFi, grey included in the monitoring set Line 1 Line 2 Line 3 Line

33 CGVision via CGLine+ Web-Controller Comprehensive visualization Up to 32 CGLine+ web controllers can be visualized at once Both CGLine+ luminaire systems and other emergency lighting systems (for example ZB-S, LP- STAR, AT-S+) can be monitored with a single software Central control and test functions Comprehensive electronic log book for all connected systems State of the individual emergency lighting systems can be presented on a site plan Visualization of individual luminaires in building layouts Access to the webserver of the CGLine+ Web-Controller possible at the same time Additional access to the Web- Controller via a web browser from any PC on the network Up to 32 Web-Controller with max. 800 luminaires each = luminaires CGVision: Configuration und complete visualization of all luminaires Printing out the log book 33

34 CGVision Anwendungsbeispiel 34

35 Comparison CGLine+ / CGLine 400 CGLine+ CGLine 400 Max. 800 Luminaires (4 x 200 or 2 x 400) 8 Zones per line with 4 lines / 16 Zones with 2 lines 8 different test groups for FT und DT free assignable Blocking of the emergency lighting function (All / per line / per zone or per luminaire) Switch off / on of maintained mode luminaires (All / per line / per zone / per luminaire) Max. 400 Luminaires (4 x 100) test groups (even / odd short address) Blocking of the emergency lighting function (All or per line) Switch off / on of maintained mode luminaires (All / per line) Visualization of the luminaires in up to 30 different floor plans via the Web- Server

36 Comparison CGLine+ / CGLine 400 CGLine+ CGLine 400 0,5 mm 2 => 330 m 1,0 mm 2 => 660 m 1,5 mm 2 => 1000 m 1 x S1/S2 Input (Blocking function with differential loop monitoring) 2 x Digital Input - - 0,5 mm 2 => 450 m 1,0 mm 2 => 900 m 1,5 mm 2 => 1350 m 1 x S1/S2 Input (Blocking function with differential loop monitoring) 2 x potential free contact 1 x potential free contact Log book stored on internal storage 1 x USB Host, 1 x USB Device SD card reader Log book in TXT (pro Month) or in DAT format (complete) via Intranet downloadable. DAT file via PC Software readable and analyzable Log boog only on SD card (w/o SD card no log book entries)

37 Comparison CGLine+ / CGLine 400 CGLine+ CGLine 400 Log book on USB Stick storable and transportable Configuration data via USB Device loadable (cable connection USB PC necessary) For DIN rail; 12 TE Cross section / dimensions suitable for Standard cut-outs for substations Operating manual stored directly in the Controller Log book on SD card storable and transportable Configuration data via SD card loadable (transportable) For DIN rail; 10 TE

38 CGLine+ / CGLine 400 mode CGLine+ mode Maximum of 800 CGLine+ luminaires (one type) CGLine 400 mode Hybrid operation of CGLine+ and CGLine luminaires in one line on a CGLine+ controller it is possible. However, as soon as one CGLine luminaire is installed in a line, the controller only operates in the older CGLine 400 mode! (the new features of the CGLine+ system are then no longer available. e.g. only 4 lines at max. 100 luminaires) CGLine+ can also be connected to the predecessor models "CGLine Web Interface" and "CG-Controller CGLine 400". 38

39 Order codes Order code Type CGLine+ Web-Controller CGLine+ PC-Software CGLine+ Web-Controller connection box Order code Type CGLine+ WiFi connection box CGLine+ Web-Controller + WLAN access point in one wall connection box CGLine+ Wireless Monitoring Set CGLine+ WiFi-connection box + ipad* Air, 32 GB, WiFi, grey 39

40 CGLine+ luminaires

41 Functional principle of the der luminaire Mains p - Controller I Charging unit t 41

42 Portfolio luminaires CGLine+ GuideLed GuideLed SL Exit Cube LED Atlantic Led, IP LED Available from April

43 Portfolio luminaires CGLine+ Alte Sachnummer/ Old part number Neue Sachnummer/ New part number GuideLed CGLine+ 20m/ 30m Wall mounting, surface 10811/11811 CGLine Wall mounting, recessed CGLine Wall mounting, recessed CGLine+ Ceiling mounting, rope, recessed /11826 CGLine+ Alte Sachnummer/ Old part number Neue Sachnummer/ New part number GuideLed CGLine+ 20m Ceiling mounting CGLine Ceiling moun., pendant 0,5m CGLine Ceiling moun., pendant 1,5m CGLine Ceiling mounting, recessed CGLine Ceiling mounting, rope CGLine+ Alte Sachnummer/ Old part number Neue Sachnummer/ New part number GuideLed CGLine+ 30m Ceiling mounting CGLine Ceiling moun., pendant 0,5m CGLine Ceiling moun., pendant 1,5m CGLine Ceiling mounting, recessed CGLine Ceiling mounting, rope CGLine+ 43

44 Portfolio luminaires CGLine+ Alte Sachnummer/ Old part number Neue Sachnummer/ New part number GuideLED SL CGLine GuideLed SL CGLine GuideLed SL CGLine GuideLed SL CGLine GuideLed SL CGLine GuideLed SL CGLine+ 5 Lux GuideLed SL CGLine+ 5 Lux Alte Sachnummer/ Old part number Neue Sachnummer/ New part number Atlantic LED CGLine Atlantic LED S 1-8H/D CGLine Atlantic LED D 1-8H/D CGLine Atlantic LED R 1-8H/D CGLine Atlantic LED O 1-8H/D CGLine Outdoor Wall 1-8H/D CGLine Atlantic LED S 1-8H/D CGLine+ H Atlantic LED D 1-8H/D CGLine+ H Atlantic LED R 1-8H/D CGLine+ H Atlantic LED O 1-8H/D CGLine+ H Outdoor Wall 1-8H/D CGLine+ H Alte Sachnummer/ Old part number Neue Sachnummer/ New part number Andere Typen/ Other luminaires h/D LED CGLine Exit Cube CGLine+ 44

45 Portfolio luminaires CGLine+ (Q3 / 2015) Style Variant LED / Style Industrie LED / Aluminium / IP 65 Brillant LED 1883, 1884, Eaton, All Rights Reserved. 45

46 Available from Q Available from Q Portfolio luminaires CGLine+ (Q3 / 2015) Alte Sachnummer/ Old part number Neue Sachnummer/ New part number STYLE LED CGLine h/D LED CGLine h/D LED CGLine h/D LED CGLine+ (SET) h/D LED CGLine+ (SET) h/D LED CGLine h/D LED CGLine+ Alte Sachnummer/ Old part number Neue Sachnummer/ New part number Style Industry LED CGLine h/D LED CGLine h/D LED CGLine+ Alte Sachnummer/ Old part number Neue Sachnummer/ New part number Brillant LED CGLine h/D LED CGLine h/D LED CGLine h/D LED CGLine+ Alte Sachnummer/ Old part number Neue Sachnummer/ New part number Aluminium LED CGLine h/D LED CGLine h/D LED CGLine+ WM h/D LED CGLine+ DM h/D LED CGLine+ PM Alte Sachnummer/ Old part number Neue Sachnummer/ New part number 6811 LED CGLine h/D LED CGLine+ 46

47 Operation in AT mode Line ID: A0 08 F0 ID: C0 0E A2 ID: EF A0 3D ID: 46 FC A8 Automatic function test (weekly) and duration test (every 3 months) even with interrupted bus line. 47

48 New indication CGLine+ luminaires Intelligent self-contained luminaires with microprocessor control On-going monitoring of the battery circuit Fully automated function test and duration test Status indication at the luminaire Indication of Bicolour-LED Operating mode LED No failure lights up green Emergency mode LED is off Delay of mains return / blinks green/yellow alternately at 0.5 Hz Function test active / blinks green 1 Hz Duration test active Luminaire blocked / blinks green/yellow alternately at 1 Hz Error messages LED Charge fault / Function test failed / Duration test failed yellow light blinks slowly at 0.5 Hz Luminaire fault yellow light blinks rapidly at 2 Hz 48

49 OLD indication CGLine 400 luminaires Intelligent self-contained luminaires with microprocessor control On-going monitoring of the battery circuit Fully automated function test and duration test Status indication at the luminaire Indication of Bicolour-LED Operating mode LED Emergency standby lights up green Emergency LED is off Delay of mains return / blinks green/yellow in rotation Function test blinks green Duration test flashes green Luminaire is blocked blinks yellow Failure indication Charging failure flashes red Function test failed / blinks green/red in rotation Duration test failed / blinks green/red in rotation Lamp failure / blinks yellow/red in rotation No duration test during last 12 lights up yellow month 49

50 CEAG Notlichtsysteme GmbH, Senator-Schwartz-Ring 26, D Soest 50

All safety luminaires are important. They help protect the life and health of people.

All safety luminaires are important. They help protect the life and health of people. All safety luminaires are important. They help protect the life and health of people. Emergency lighting must be fully functional to provide protection in case of failure of the general lighting. Even

More information

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved.

LP-STAR. Compact emergency lighting power supply with STAR technology Eaton, All Rights Reserved. LP-STAR Compact emergency lighting power supply with STAR technology Central overall fire protection section installation Advantages: One distributor for all emergency light circuits Central distributor

More information

CGVision Package I. Visualisation software CGVision. CGVision Package I application example

CGVision Package I. Visualisation software CGVision. CGVision Package I application example Visualisation software CGVision CGVision Package I CGVision Package I (Basic or Pro) contains the CG-S/IP interface ( dongle) enabling CG-S bus-based emergency light systems such as, LP-STAR, and CG2000

More information

CGVision Package I. Visualisation software CGVision. CGVision Package I application example

CGVision Package I. Visualisation software CGVision. CGVision Package I application example Visualisation software CGVision CGVision Package I CGVision Package I (Basic or Pro) contains the CG-S/IP interface (USB dongle) enabling CG-S bus-based emergency light systems such as, LP-STAR, AT-S +

More information

The correct license for your application

The correct license for your application The correct license for your application CGVision visualisation software is available in three different packages in the Basic or Pro versions. The packages essentially differ with the CG-S interface for

More information

Installation and Operating Instructions. PC Software CGLine+ Web-Controller

Installation and Operating Instructions. PC Software CGLine+ Web-Controller PC Software CGLine+ Web-Controller Installation and Operating Instructions PC Software CGLine+ Web-Controller Target group: Installer, end user PC Software CGLine+ Web-Controller Content INTRODUCTION /

More information

Operating Instructions Webmodule ZB-S

Operating Instructions Webmodule ZB-S Target group: Skilled electricians 400 71 860 051 (A) Index 1 Safety Instructions... 3 2 Conformity with standards... 3 3 Technical data... 3 3.1 Description / Scope of application... 3 4 Installation...

More information

Central Battery System ZB-S Eaton, All Rights Reserved.

Central Battery System ZB-S Eaton, All Rights Reserved. Central Battery System ZB-S Central Battery System ZB-S Agenda New charging technology System Configuration Internal Modules External Modules Battery Management System PC Software CG Vision Date, Venue

More information

LP-STAR emergency lighting power supply in a compact design Installation example

LP-STAR emergency lighting power supply in a compact design Installation example Installation example LP- STAR Ethernet LP- STAR Ethernet Ethernet LP- STAR Ethernet Example connection to the central visualisation system CG Vision Building 2 Ethernet CG-S bus Building 1 IP router Central

More information

CEAG HandRail 930XX LED. Hand rail mounted Luminaire for all applications

CEAG HandRail 930XX LED. Hand rail mounted Luminaire for all applications CEAG HandRail 930XX LED Hand rail mounted Luminaire for all applications Safety luminaire When confronted with emergency lighting applications where a ceiling or post top mounting is not possible, Eaton

More information

LP-STAR emergency lighting power supply in a compact design Installation example

LP-STAR emergency lighting power supply in a compact design Installation example Installation example LP- STAR Ethernet LP- STAR Ethernet Ethernet LP- STAR Ethernet Example connection to the central visualisation system CG Vision Building 2 Ethernet CG-S bus Building 1 IP router Central

More information

Short Instructions CG-S / IP-Router

Short Instructions CG-S / IP-Router 1 General Information This device is designed and built in conformity with the latest technical rules at the time of its development and production, so it is safe to operate. Danger maybe presented by

More information

Mounting and operating instructions

Mounting and operating instructions CEAG Webmodule CG-S LP-STAR Mounting and operating instructions CEAG Webmodule CG-S LP-STAR Target group: Skilled electricians CEAG Webmodule CG-S LP-STAR Content 1 SAFETY INSTRUCTIONS....3 2 CONFORMITY

More information

CGLine+ Self-contained luminaire monitoring system. Simply the most flexible, reliable monitoring for peace of mind

CGLine+ Self-contained luminaire monitoring system. Simply the most flexible, reliable monitoring for peace of mind CGLine+ Self-contained luminaire monitoring system Simply the most flexible, reliable monitoring for peace of mind Energizing a world that demands more. Discover today s Eaton. Powering business worldwide

More information

IP gateway, MDRC IG/S 1.1, GH Q R0001

IP gateway, MDRC IG/S 1.1, GH Q R0001 , GH Q631 0067 R0001 The IP gateway IG/S is the interface The IP address of the IG/S can be between EIB / KNX installations and IP fixed or received from a DHCP server. CDC 071 130 F0003 networks. Data

More information

Configure Connect Communicate

Configure Connect Communicate Configure Connect Communicate Introduction One-CONNECT: a comprehensive DALI based scalable emergency lighting test system. One-CONNECT is a flexible, powerful and user friendly emergency lighting test

More information

SicuroLED-G - advantages

SicuroLED-G - advantages 6 SicuroLED-G - advantages For emergency lightings with external supply escape routes, areas with particular panic hazard, workplaces with particular people hazard and safety devices can be illuminated

More information

RUSIC 24. LPS Central supply system for emergency luminaires 24 V for separate fire areas

RUSIC 24. LPS Central supply system for emergency luminaires 24 V for separate fire areas RUSIC 24 LPS Central supply system for emergency luminaires 24 V for separate fire areas Wiring system with all advantages of safety extra-low voltage (SELV) Energy-optimised by use of LED luminaires with

More information

LPS Central supply system for emergency luminaires 24 V for separate fire areas

LPS Central supply system for emergency luminaires 24 V for separate fire areas RUSIC 24 LPS Central supply system for emergency luminaires 24 V for separate fire areas Wiring system with all advantages of safety extra-low voltage (SELV) Energy-optimised by use of LED luminaires with

More information

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply Emergency CATALOGUE Vol. 01 Lighting Decentralised and centralised supply Light is safety Light must be safe! Interior luminaire, exterior luminaire and emergency luminaire are all important to ensure

More information

Emergency Lighting. Catalogue. Central Power systems

Emergency Lighting. Catalogue. Central Power systems Emergency Lighting Catalogue Central Power systems Beghelli-Präzisa GmbH is constantly developing and improving the product range. All descriptions, illustrations, drawings and specifications present only

More information

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035 Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20

More information

VMB1RY. Relay Module for VELBUS system. Velbus manual VMB1RY edition 1 rev.1.0

VMB1RY. Relay Module for VELBUS system. Velbus manual VMB1RY edition 1 rev.1.0 VMB1RY Relay Module for VEL system 1 INDEX Features... 3 Velbus data... 4 Connection... 5 Direct control with several push buttons... 6 Control via VEL system... 6 Combination of direct push button control

More information

Use of the application program

Use of the application program Table of contents Use of the application program 1 1. Functional description 1 2. Communication objects 3 3. Parameters 3 IP Settings 3 Setting the additional individual address of the IP Interface with

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. Digital Lighting Systems, Inc. Four Channel Dry Contacts Relays Switch Pack DMX512 compatible USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION The is a 4-channel DMX-512 compatible electro-mechanical

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

Agenda. August 23, 2017 Slide 2

Agenda. August 23, 2017 Slide 2 Welcome IP Basic Agenda 01 Product portfolio 02 Planning (1) power consumption rule (2) distance rule 03 Commissioning (1) device detail (2) commission overview a. addressing b. programming access 04 Typical

More information

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22) .3 Ex-Linear light fittings for fluorescent lamps ellk 9 18 W 58 W / ellm 9 18 W 36 W (Zone 1,, 1, ) The classic lighting solution in hazardous areas The ellk 9 linear luminaire series for fluorescent

More information

HandRail 930XX LED Safety Luminaires for Escape Route Lighting

HandRail 930XX LED Safety Luminaires for Escape Route Lighting When confronted with emergency lighting applications where a ceiling or post top mounting is not possible, Eaton offer a broad innovative low power hand hail mounted emergency luminaire. The hand rail

More information

Use of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016.

Use of the application program. 1. Functional description. instabus EIB Application Program Description. August 2016. IP- 001031 Table of contents Use of the application program 1 1. Functional description 1 2. Communication objects 4 3. s 4 General 4 Routing (Bus > IP) 4 Routing (IP > Bus) 5 IP 5 Setting the additional

More information

SK CU4-EIP-C Part number:

SK CU4-EIP-C Part number: SK CU4-EIP-C Part number: 275 271 519 EtherNet/IP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Communicative controller for VAV systems

Communicative controller for VAV systems FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

CEAG CG-Controller for CG 2000/ZB-S

CEAG CG-Controller for CG 2000/ZB-S CEAG CG-Controller for CG 2000/ZB-S Operating Instructions Target group: Skilled electricians Contents 1 Safety Instructions.... 4 2 Important information about safety at work and the safe operation of

More information

MINI CLOCK CAMERA HD HIDDEN CLOCK DVR SKU: MiniClockCamHD

MINI CLOCK CAMERA HD HIDDEN CLOCK DVR SKU: MiniClockCamHD THANK YOU FOR PURCHASING THE MINI CLOCK CAMERA HD HIDDEN CLOCK DVR MINI CLOCK CAMERA HD HIDDEN CLOCK DVR SKU: MiniClockCamHD Please read this manual before operating the mini clock camera HD and keep it

More information

Walls/Surface Hanging. Bulkhead. 4w 190 lm. 7w 600 lm Salient Features

Walls/Surface Hanging. Bulkhead. 4w 190 lm. 7w 600 lm Salient Features LED Emergency Lights V-TAC features a line of premium quality LED emergency lights for clear and bright emergency illumination. Inclusive of evident exit signs, these signs are powered by high performance

More information

DIAGNOSTICS PN# / / FSP

DIAGNOSTICS PN# / / FSP Diagnostic Monitoring These units are designed for data capturing simple measurements (pressure, temperature, and flow rate) in hydraulic and pneumatic systems. Typical applications extend primarily to

More information

Solenvis SL80 Pulse to M-Bus Converters

Solenvis SL80 Pulse to M-Bus Converters Solenvis SL80 Pulse to M-Bus Converters The SOLENVIS SL80 series of devices connects meters with contact output to the M-Bus system. This is a simple and flexible solution for reading already installed

More information

Barefoot Power Ltd 2013 v1.4

Barefoot Power Ltd 2013 v1.4 Save money No running costs Improve health No smoke or burns Generate income Charges phones and devices Improve education Light for studying Save the environment No kerosene or fumes Power Appliances The

More information

FC724 Fire control panel

FC724 Fire control panel FC724 Fire control panel Series FS720 (MP3.0) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as

More information

FC722 Fire control panel

FC722 Fire control panel FC722 Fire control panel Series FS720 (MP3.0) Cerberus PRO Compact, prefabricated microprocessor-controlled fire control panel for the connection of up to 252 addresses Fire control panel can be used as

More information

lphasoft Pty Ltd TCM LANDING CALL SERVER - LCS version 30 Jun 2015

lphasoft Pty Ltd TCM LANDING CALL SERVER - LCS version 30 Jun 2015 lphasoft Pty Ltd Azalea Place LOFTUS NSW (6) 9576 68 009 57 55 sales@alphasoft.com ABN 7 00 66 TCM LANDING CALL SERVER - LCS version 0 Jun 05 The Alphasoft TCM Landing Call Server/Splitter (LCS) is intended

More information

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Energy meters Single phase electrical energy meters WM1-6 / WM1M6 Energy meters Single phase electrical energy meters WM1-6 / WM1M6 o Single phase direct connected DIN-rail mounting meter o Class 1 for active energy according to EN 62053-21 and B according to EN 50470-3

More information

Display Panel BAT 100 LSN. en Operation Guide

Display Panel BAT 100 LSN. en Operation Guide Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance

More information

LRA1750, LRM1763, LCC172x Datasheet OccuSwitch Wireless System

LRA1750, LRM1763, LCC172x Datasheet OccuSwitch Wireless System 1/8 RM1763 Occuswitch Wireless sensor 8.1 mm 25 mm 56.4 mm General description The OccuSwitch Wireless family exists of a wireless sensor and an actuator (relay-box). Savings of up to 30% can be achieved

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this

More information

LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE

LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE LINE 21 INTERNET ACCESS THROUGHOUT THE HOUSE Fed up with your Internet access being restricted to a single room? Would you like access available in any room in the house that has a telephone socket? For

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , ,

LINEAR LED DRIVERS. ComfortLine NFC. ComfortLine NFC , , , LINEAR LED DRIVERS ComfortLine NFC 186697, 186698, 186699, 186700 Typical Applications Built-in in linear luminaires for Office lighting Industrial lighting ComfortLine NFC SELECTABLE OUTPUT CURRENT (NFC)

More information

Operating and mounting instructions

Operating and mounting instructions General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore

More information

DALI Professional Controller-4. Control unit Operating instructions

DALI Professional Controller-4. Control unit Operating instructions LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections

More information

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K F3102 / F3107 / F3110 / F3115 / F3210 / F3215 86085K3000020 PN: 86085K3000030 Zavio F3102/F3107/F3110/F3115/F3210/F3215 Quick Installation Guide Please follow the installation steps below to set up F3102

More information

Motion Activated Camera

Motion Activated Camera Motion Activated Camera User Manual MAC 200 www.brinno.com Register@online http://www.brinno.com/support/register.html contact us: customerservice@brinno.com more information: www.brinno.com WEL COME TO

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1.

PSI-MODEM-SHDSL/PB. Broadband PROFIBUS extender, SHDSL PROFIBUS leased line modem. Data sheet _en_03. 1 Description. 1. PSI-MODEM-/PB Broadband PROFIBUS extender, PROFIBUS leased line modem Data sheet 104396_en_03 1 Description PHOENIX CONTACT 2013-08-21 1.1 Features The PROFIBUS extender can be used to easily network PROFIBUS

More information

Gateway Ascii Command Protocol

Gateway Ascii Command Protocol Gateway Ascii Command Protocol Table Of Contents Introduction....2 Ascii Commands.....3 Messages Received From The Gateway....3 Button Down Message.....3 Button Up Message....3 Button Maintain Message....4

More information

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K

TROXNETCOM AS-i. Modules. Communication interface between a component and the controller. 06/2015 DE/en K .2 X X testregistrierung TROXNETCOM AS-i Communication interface between a component and the controller The module is used to connect the control system with the components Integral AS-Interface slave

More information

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack

Digital Lighting Systems, Inc. PD405-DMX. Four Channel Dimmer and Switch Packs. DMX512 compatible. PD405-DMX-24DC DMX512 4 x 5 Amps Dimmer Pack Digital Lighting Systems, Inc. PD405DMX Four Channel Dimmer and Switch Packs DMX52 compatible PD405DMX24DC DMX52 4 x 5 Amps Dimmer Pack C UL US LISTED www.digitallighting.com Digital Lighting Systems,

More information

EC-BOS-8 Multi-protocol Web Building Controller

EC-BOS-8 Multi-protocol Web Building Controller Datasheet Multi-protocol Web Building Controller Overview Features & Benefits The is a compact, embedded controller and server platform for connecting multiple and diverse devices and sub-systems. With

More information

Challis Ag+ WSM. Water Management System

Challis Ag+ WSM. Water Management System Challis Ag+ WSM Water Management System Challis Ag+ WMS Executive Summary The Challis Ag+ WMS is a new, top-of-the-range, modular and electronic Intelligent technical building water monitoring and control

More information

Motion Activated Camera

Motion Activated Camera Motion Activated Camera User Manual MAC200 DN www.brinno.com 1 Register@online http://www.brinno.com/support/register.html contact us: customerservice@brinno.com more information: www.brinno.com WEL COME

More information

POWER & ENERGY LOGGER MODEL PEL 102 & PEL 103

POWER & ENERGY LOGGER MODEL PEL 102 & PEL 103 POWER & EERGY LOGGER MODEL PEL 102 & PEL 103 Quick Start Guide EGLISH www.aemc.com CHAUVI AROUX GROUP Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument

More information

KNX DALI Gateway Plus - User Manual

KNX DALI Gateway Plus - User Manual KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29

Linienkoppler S KNX. Line coupler S KNX. Line coupler S KNX Status: March 16 (Subject to change) Page 1 of 29 Linienkoppler S KNX Line coupler S KNX Line coupler S KNX 9070880 Status: March 16 (Subject to change) Page 1 of 29 KNX Contents Contents Page 1 General... 3 1.1 Using the product manual... 3 1.1.1 Structure

More information

BMS-Ethernet-Gateway COM460IP

BMS-Ethernet-Gateway COM460IP BMS-Ethernet-Gateway TDB501015en / 11.2012 BMS-Ethernet-Gateway BMS-Ethernet-Gateway Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between BMS bus and Ethernet Range of

More information

COMTRAXX COM460IP. BMS-Ethernet-Gateway

COMTRAXX COM460IP. BMS-Ethernet-Gateway COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP_D00023_03_D_XXEN/11.2015 COMTRAXX COM460IP BMS-Ethernet-Gateway COM460IP Device features Modular, expandable gateway between BMS bus and TCP/IP Gateway between

More information

Sauter Systems

Sauter Systems 96.692/1 EYZ 292:, interface The is a interface for connecting the CASE Suite/ programming tools and the various novapro software on the management level to the EY3600 system with in a local area network

More information

SK CU4-PNT-C Part number:

SK CU4-PNT-C Part number: SK CU4-PNT-C Part number: 275 271 515 PROFINET IO Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

EC-BOS-8 Multi-protocol Web Building Controller

EC-BOS-8 Multi-protocol Web Building Controller Datasheet EC-BOS-8 Multi-protocol Web Building Controller Overview Features & Benefits The EC-BOS-8 is a compact, embedded controller and server platform for connecting multiple and diverse devices and

More information

DIN-RAIL EXPANDER int-iors_en 10/14

DIN-RAIL EXPANDER int-iors_en 10/14 INT-IORS INT-ORS DIN-RAIL EXPANDER int-iors_en 10/14 The INT-IORS expander enables the system to be expanded by 8 programmable wired zones and 8 programmable wired outputs. The INT-ORS expander enables

More information

SDP:01. Scania Diagnos & Programmer 3. en-gb. User instructions Applies from SDP Issue 19. Scania CV AB 2014, Sweden

SDP:01. Scania Diagnos & Programmer 3. en-gb. User instructions Applies from SDP Issue 19. Scania CV AB 2014, Sweden SDP:01 Issue 19 en-gb Scania Diagnos & Programmer 3 User instructions Applies from SDP3 2.18 Scania CV AB 2014, Sweden Introduction... 3 General... 3 System requirements and ancillary equipment... 4 System

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this

More information

IT-467-*-BT 22" (1680 x 1050)

IT-467-*-BT 22 (1680 x 1050) IT-467-*-BT 22" (1680 x 1050) The IT-467-*-BT with luminous 22" display is the Panel PC of the future for all widescreen applications in industrial areas. The 1680 x 1050 pixel resolution (WSXGA) is the

More information

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001

Control unit for lux control, MDRC Type: SL/S 50.1, GH Q R0001 SK 0012 B 98 The control unit is a DIN rail mounted device for insertion in the distribution board. It is used to control digitally dimmable electronic ballast devices or transformers via the EIB. In a

More information

Walls/Surface Hanging. Bulkhead. 4w 190 lm. 7w 600 lm Salient Features

Walls/Surface Hanging. Bulkhead. 4w 190 lm. 7w 600 lm Salient Features LED Emergency Lights V-TAC features a line of premium quality LED emergency lights for clear and bright emergency illumination. Inclusive of evident exit signs, these signs are powered by high performance

More information

TS 981 door control TS 981 Control panel with traffic management for DES. Approvals and certificates

TS 981 door control TS 981 Control panel with traffic management for DES. Approvals and certificates TS 98 door control Control panel with traffic management for GfA ELEKTROMATEN drives with DES digital limit switch Approvals and certificates TS 98 TS 98 / TS 98 FT Type test according to: DIN EN DIN EN

More information

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module

Digital Lighting Systems, Inc. CD400-DMX DMX512 Four Channel Dimmer and Switch module , Inc. DMX512 Four Channel Dimmer and Switch module Input: 5 Amps @ 6-24 VDC Outputs: 5 Amps Maximum each, total 4 outputs 8 Amps Maximum. FRONT BACK USER'S MANUAL -UM User's Manual - Page 1 GENERAL DESCRIPTION

More information

ACTpro 1500 Single Door IP Controller

ACTpro 1500 Single Door IP Controller ACTpro 1500 Single Door IP Controller ACTpro 1520 Single Door IP Controller with 12 V DC 2 amp power supply. Operating & Installation Instructions 18-00085 Issue 2 This manual refers to the ACTpro 1500

More information

SMARTSCAN INFORMATION

SMARTSCAN INFORMATION SMARTSCAN INFORMATION SL4 (014) SERIES SAFETY LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.co.uk,

More information

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH)

COMPACT LED DRIVERS. PrimeLine DALI dimmable & Selectable Current (Dip Switch) PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) COMPACT LED DRIVERS PrimeLine DALI DIMMABLE & SELECTABLE CURRENT (DIP SWITCH) 186762, 186763 Typical Applications Built-in in compact luminaires Shop lighting Downlights PrimeLine DALI dimmable & Selectable

More information

Digital Lighting Systems, Inc.

Digital Lighting Systems, Inc. , Inc. PD402-DMX Four Channel Dimmer and Switch Packs 4 x 2.5 Amps @ 6VDC to 24 VDC DMX52 compatible DMX52 4 x 2.5 Amps Dimmer Pack C UL US LISTED Digital Lighting Systems, Inc. USER'S MANUAL User's Manual

More information

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable 6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable Product ID: IES61002POE The IES61002POE 6-Port Industrial PoE+ switch lets you connect

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

connecdim Gateway G1 Ethernet TCP/IP to DALI

connecdim Gateway G1 Ethernet TCP/IP to DALI Gateway G1 Ethernet TCP/IP to LI Independent lighting control for up to 256 LI gears on 4 LI lines Can be expanded by connecting multiple gateways on the same network Cloud based web interface for configuration

More information

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Manual# 1006495 Installation Manual 200E Series DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Installation Manual for the Marine Pro 200E Series ~~~ DCU 210E/208E Diesel Engine Control Unit RP 210E/220E

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22) . Ex-Linear LED light fittings ellk/m 9 LED 400/800 / ellk/m 9 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1,, 1, ) The efficient solution for your explosion-protected lighting concept The explosion-protected

More information

C-DIAS EtherNet/IP Slave CIP 022

C-DIAS EtherNet/IP Slave CIP 022 C-DIAS-ETHERNET/IP SLAVEMODUL CIP 022 C-DIAS EtherNet/IP Slave CIP 022 The C-DIAS EtherNet/IP CIP 022 slave module is an interface module between the C-DIAS control system and EtherNet/IP bus. Technical

More information

DaisaTest System.

DaisaTest System. DaisaTest System www.daisalux.com Index 1 WHAT IS A DAISATEST SYSTEM... 5 2 FUNCTIONS OF DAISATEST SYSTEM... 5 2.1 Monitoring the status of the emergency lighting... 5 2.2 Facilitating installation maintenance

More information

Sicat CMS. siemens.com/mobility. Catenary monitoring system for overhead contact line systems

Sicat CMS. siemens.com/mobility. Catenary monitoring system for overhead contact line systems The contactless catenary monitoring system Sicat CMS continuously monitors the tensile forces in the contact wire and catenary wire and also acquires and evaluates the information. The filtered information

More information

Industrial Single-Port 10/100/1000Mbps 802.3bt PoE Injector (95 Watts, -40~75 degrees C, 12~48V DC)

Industrial Single-Port 10/100/1000Mbps 802.3bt PoE Injector (95 Watts, -40~75 degrees C, 12~48V DC) Industrial Single-Port 10/100/1000Mbps 802.3bt Injector (95 Watts, -40~75 degrees C, 12~48V ) Interface 2 RJ45 interfaces 1-port + output 1-port input 1 terminal block for master and slave power input.

More information

Catalog. IP video door intercom system for smartphones and tablets (ios, Android)

Catalog. IP video door intercom system for smartphones and tablets (ios, Android) Catalog IP video door intercom system for smartphones and tablets (ios, Android) myintercom in action... 1. Surf the Internet in the garden 2. The driveway entrance bell rings* 3. "I'll open for you."

More information

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable.

General Information. FAST-STAT wiring extenders electronically add more wires to a control cable. General Information FAST-STAT wiring extenders electronically add more wires to a control cable. Saves significant time and expense as compared to repulling of new cables. Causes no damage to walls or

More information

WHAT IS A BUS? FUNDAMENTALS OF BUS PROTECTION. Kevin Wright Senior Protection Engineer Sacramento Municipal Utility District

WHAT IS A BUS? FUNDAMENTALS OF BUS PROTECTION. Kevin Wright Senior Protection Engineer Sacramento Municipal Utility District WHAT IS A BUS? FUNDAMENTALS OF BUS PROTECTION Kevin Wright Senior Protection Engineer Sacramento Municipal Utility District 5 WHAT IS A BUS? All connections are at the same voltage. WHAT IS A BUS? All

More information

RS 232 PINOUTS. 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out.

RS 232 PINOUTS. 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out. RS 232 PINOUTS 1. We use RJ12 for all of our RS232 interfaces (Link-2-Modbus & Link-2-PC- Serial/RS232). The diagram below shows our pin out. 2. A DB9 Female to RJ12 Female Serial/Terminal Modular Adaptor

More information

FC726 Fire control panel

FC726 Fire control panel FC726 Fire control panel FS720 series (MP3.0) Cerberus PRO Modular, prefabricated, microprocessor-controlled fire control panel with integrated user-friendly operating unit for up to max. 52 addresses

More information

SmartAir Master. The intelligent compressed air management system Developed by Compair to save your customers money

SmartAir Master. The intelligent compressed air management system Developed by Compair to save your customers money SmartAir Master The intelligent compressed air management system Developed by Compair to save your customers money Customers will need more Energy Efficient Systems Why do we make more energy efficient

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

our experience...your solution Controlling and Monitoring Gateway

our experience...your solution Controlling and Monitoring Gateway our experience......your solution Controlling and Monitoring Gateway FEATURES Clearly readable dark-blue display (4x20), 8 key keyboard and 8 signaling LEDs provides a comprehensive overview of the system

More information