1 1/8 RM1763 Occuswitch Wireless sensor 8.1 mm 25 mm 56.4 mm General description The OccuSwitch Wireless family exists of a wireless sensor and an actuator (relay-box). Savings of up to 30% can be achieved by simply turning the lights off in unoccupied areas. The OccuSwitch Wireless is designed for an area of 20 to 25 m2, but the area can be expanded to 160 m2 by adding extra sensors. It is possible to link up to 10 sensors and actuators per network. The wireless sensor enables easy installation and mounting onto the ceiling or any location. The actuator is connected to the mains wiring at a convenient place in the (corridor) ceiling. The OccuSwitch Wireless family exists of: RM1763/00 Wireless Sensor (Movement detector and daylight override) RA1750/00 Wireless Universal Actuator CC1720/00 Wieland cable for the Actuator CC1723/00 Cable with standard mains plug (type F meets Europe) CC1727/00 Cable with standard mains plug (type E meets France a.o.). ø 83.6 mm ø 83.6 mm RM1763 dimensions Mounting plate dimensions CC1720 Wieland cable CC1723 St plug type F CC1727 St plug type E GST18i3 or plug F or E GST18i3 or plug F or E 500 mm MRT3 P 5,08/6 VE RA1750 OccuSwitch Wireless actuator CC172x dimensions 154 mm 49.2 mm mm 47.2 mm RA1750 dimensions

2 2/8 Applications The OccuSwitch Wireless is designed for use in offices and similar applications like classrooms, including restrooms, corridors, storage and copy rooms, break areas, etc. The OccuSwitch Wireless detection pattern (see drawing) is 3.6 by 5.4 meters for small movements (desk work) and 5.4 by 7.2 meters for larger movement like walking. 3.6m 5.4m h = m 3.6 m 5.4 m Standard application 5.4m 3.6m 5.4 m h = 2.5 m 7.2 m 3.6m 5.4m Detection pattern Parallel design Parallel design is used to enlarge the coverage area of OccuSwitch Wireless. It is possible to connect up to 10 devices in a single wireless network. When one of the sensors detects movement all actuators will switch the lights on. With the sensors OccuSwitch Wireless can cover a variety of areas. The actuator can switch any load up to 6A (1380 VA). This has to be taken in account when luminaires are connected to the actuator To give an impression of the possibilities, 3 network designs are shown. etwork 1 and 2 show a design with 1 actuator and multiple sensors. The maximum distance between the actuator and the sensor is 10 m. etwork 3 show a design with multiple actuators and sensors, and the actuators are separated from the sensors by a wall (wood, stone with plaster or system wall, no reinforced concrete wall). The wall interferes the signal and reduces the maximum distance. The maximum distance between the actuators is 10 m. The maximum distance between a sensor and the closest actuator is 8 m.. Position OccuSwitch Wireless sensor Functions Automatic Control The OccuSwitch Wireless switches the lights on automatically when presence is detected and switches the lights off 1 to 30 minutes after the area is vacated. Daylight override It is possible to prevent the automatic switch on when sufficient daylight is available and only switch on when the daylight level drops below the required level. To enable this function it is necessary to set the required light level on the sensor. (See Menus on page 6). Features Smart timer On some occasions with very little movement it is possible that the standard delay time of the sensor is too short. If movement is detected immediately after switch off, the lights will switch on immediately and the delay time is automatically increased by 5%. Shield To prevent detection from areas like corridors, the sensor has a retractable shield that can be used to shield off areas. Pull out the sensor shield (indicated on the ring with a dot) and rotate it to the required side.

3 3/8 Channel change The channel change settings can be used to change the communication channel if needed to mitigate wireless interference. The channel change selects the best available channel to provide secure, reliable communication between devices. Power up state The power-up state is the action taken by the actuator after it is connected to the mains for the first time or when there has been a power failure. The power-up state can be set to OFF or O by configuring the actuator. ormal operation resumes after 30 seconds: o movement detection: lights will stay off. Movement detection and insufficient daylight: lights will switch on. USB interface The USB interface enables quick and simple software upgrades in the field and should be used by Philips engineers only. Replace sensor battery! Caution: Make sure first to read the SAFETY section before replacing the battery. To replace the battery of the sensor: Step 1 Rotate the sensor counterclockwise to remove it from the mounting plate. Step 2 In a safe and dry place, remove the old battery and insert a new battery. Caution: Use only a high quality AA 3.6V DC lithium! battery (SAFT S 14500) in the sensor. Use of an improper rated battery may damage the sensor. Step 3 Place the sensor back on the mounting plate and rotate clockwise to install it. Step 4 Dispose the used battery in a proper way. Keep the battery away from children. Do not disassemble the battery and do not dispose the battery in fire. USB Sensor battery low indication When the battery power is low the lights will blink once after 10 seconds, every time the lights are switched on. If several sensors are used the WIK test can be selected to indicate the sensor with the low battery power. The green ED starts to blink to indicate that the WIK test is in progress. The red ED starts to blink during the WIK test to indicate the sensor with the low battery power. When the battery power on one of the sensors is too low to send a signal, the actuator will keep the lights on. The red ED on the sensor starts to blink until the battery is completely empty. Testing features Walk test (sensor coverage test) The Walk test can be used to find the best sensor location. Activate the test on the sensor and walk around in the area. The illumination of the sensor ED provides instant feedback to quickly find an ideal sensor location, reducing errors and callbacks. WIK test (show linked devices) Installers can quickly test the wireless connection between the devices in the network with the WIK test, saving time and improving efficiency. ote: It is highly recommended to replace the batteries of all sensors in a network at the same time. Indication Period Meaning ights will blink once After 10 seconds at lights on Battery power is low on one of the sensors ights on Continuously Battery power is too low to send a signal Battery is completely empty

4 4/8 Fixing Install the actuator The sensor can be mounted onto the ceiling. When selecting a location for the sensor avoid obvious cold spots so that condensation does not occur. Also do not place the sensor close to heat sources or HVAC exhausts. The window arrow on the mounting plate of the sensor must point to the window. Install the sensor ø Max. 4 mm SAFT S14500 USB Max. 1 m Min. max. 10 m Window Fe 1 Fe d > 1 m WiFi 3 h = max. 4 m 2 PHIIPS min x h ø Max. 4 mm! Warning: Avoid wireless systems like WIFI/ZIGBEE within a radius of 1 m. Wireless systems may interfere with the network signal of OccuSwitch Wireless. As a result the OccuSwitch Wireless will continuously search for a channel which leads to reduced battery life. Avoid metal walls, metal ceilings, cable ducts, reinforced concrete walls etc, between the sensor and actuator. They will block the signal. h 1.5 x h lux 1.5 x h

5 5/8 Electrical installation The sensor is equipped with a battery and does not have any electrical connection. The actuator is installed with a screw terminal or alternatively with a cable with Wieland connector or CEE connector. S CC1720 CC1723 CC1727 S S Commissioning Create a network Step 1 Briefly press the IK button on the actuator. The green ED on the actuator starts to blink. Step 2 Briefly press the IK button on the sensor. The lights blink once and switch on and the green ED on the sensor turns on in case of success, or the red ED lights up in case of failure. ote: Check if the range is within the required specification when the red ED lights up. Contact your local Philips representative if the problem can not be solved. Step 3 Briefly press the IK button on another sensor and/or actuator until the network is completed. Step 4 Press the IK button on the first actuator again to end commissioning or wait 5 minutes to end it automatically. The green ED stops to blink. Add an additional device to the existing network Step 1 Briefly press the IK button on the actuator that was initially used to setup the network. The green ED on the actuator starts to blink. Step 2 Briefly press the IK button on the sensor or another actuator. The green ED on the sensor or actuator turns on in case of success, or the red ED lights up in case of failure. ote: Check if the range is within the required specification when the red ED lights up. Contact your local Philips representative if the problem can not be solved. Step 3 Repeat step 2 until all sensors and/or actuators are added to the network. Step 4 Press the IK button on the actuator again to end commissioning or wait 5 minutes to end it automatically. The green ED stops to blink. 1 2 ( 3 4 1x 1x + = 1x = max. 10 off 1x )

6 6/8 Shield Red Yellow Green ink ink Red Yellow Green Menu EDs and buttons ED indication Period Meaning Red, yellow, green In sequence Sensor or actuator restored to default settings Blinking green 30 seconds Sensor or actuator in WIK test For longer Actuator is in linking mode Blinking yellow Every 2 seconds Actuator in configuration menu 10 seconds Sensor is in daylight override waiting to calibrate 7-10 seconds Sensor or actuator in restore default setting 10 minutes Sensor in Walk test Blinking red Every 2 seconds Sensor or actuator in action menu 30 seconds Battery power is low and shown during WIK test Regular Battery power too low to send a signal (lights stays on) Regular on actuator Actuator cannot find a sensor Slow on actuator Battery power is too low to send a signal Menus Sensor Step 1 To enter the action menu press and hold the IK button until the red ED starts to blink once every 2 seconds. Step 2 Briefly press the IK button again to go to the next menu item. Repeat until the correct menu item is selected. (See table below). Step 3 To activate the selected menu item press and hold the IK button until the green ED lights up. Red ED Item Remarks 1 blink Menu exit To exit the menu 2 blinks WIK devices The green ED on each device in the network starts to blink for 30 seconds after movement is detected. 3 blinks Walk test The yellow ED on each sensor starts to blink when movement is detected and will end after 10 minutes. 4 blinks Set daylight The yellow ED on the sensor starts to blink and after override threshold 10 seconds a snapshot will be made. Actuator Action menu Step 1 To enter the actuator menu press and hold the MEU button until the red ED starts to blink once every 2 seconds. Step 2 Briefly press the MEU button again to go to the next menu item. Repeat until the correct menu item is selected (See table below). Step 3 To activate the selected menu item briefly press the IK button. The green ED lights up. Red ED Item Remarks 1 blink Menu exit To exit the menu 2 blinks WIK devices The green ED on each device in the network starts to blink for 30 seconds after movement is detected. 3 blinks Walk test The yellow ED on each sensor starts to blink when movement is detected and will end after 10 minutes. 4 blinks Channel change The green ED on each device starts to blink and will turn green when the channel change is done successfully. In case of failure the red ED starts to blink regularly. Configuration menu Step 1 To enter the actuator menu, briefly press the MEU button. The yellow ED starts to blink once every 2 seconds. Step 2 Briefly press the MEU button again to go to the next menu item. Step 3a To set the power-up state in position OFF, briefly press the IK button. The green ED lights up. Step 3b To set the power-up state in position O, press and hold the IK button until the green ED starts to blink. Yellow ED Item Remarks 1 blink Menu exit To exit the menu 2 blinks Power-up state The actuator will keep the lights off during the first 30 seconds after power-up. After 30 seconds the actuator will function normally.

7 7/8 Walk test Step 1 Ask other persons to leave the room. Step 2 Set the time delay at 1 minute on all sensors. Step 3 Select the Walk test on one sensor and wait until the yellow ED on all sensors starts to blink. This may take a minute. Make sure the sensor detects movement. Step 4 Move around the room, corners and main workspace and check that the yellow ED blinks on all sensors. Step 5 eave the room and wait about 1 minute for the lights to switch off. Step 6 Enter the room and check that the lights switch on when passing the doorway. Step 7 Set the time delay back to the required setting on all sensors. Technical data Environmental conditions Storage conditions Temperature Relative humidity Operating conditions Temperature Relative humidity System Maximum linked -20 to +70 C 20% to 90%; no condensation +5 to +50 C 20% to 90%; no condensation 10 devices in a network Set daylight override threshold ote: Calibration must be done at night and the room must be furnished. Step 1 Press and hold the IK button on the sensor until the red ED starts to blink once every 2 seconds. Step 2 Briefly press the IK button 3 times to go to set daylight override threshold. The red ED starts to blink 4 times every 2 seconds. Step 3 Press and hold the IK button until the yellow ED starts to blink. Within 10 seconds the calibration starts. Step 4 Clear the area beneath the sensor. Step 5 The green ED lights up when the calibration is completed. Delay time occupancy control With the rotary it is possible to select a delay time between 1 and 30 minutes. Min. Restore default settings To restore the default settings of the sensor or the actuator press and hold the IK button. After 3 seconds the yellow ED starts to blink (only when sensor is used) and after 10 seconds the red, yellow, and green ED starts to blink shortly in this sequence to indicate the default settings are completed. Then the link button can be released. Expected battery life Application Intensity Battery life Office ormal use 7.5 to 10 years Classroom ormal use 7 to 9 years General Worst case 4.5 years Actuator Mains connection Frequency 50Hz Voltage 230V +/-10% Maximum load 6A (1380VA lighting) Connector screw terminal MRT3P5.08/6VE (STEVIO) Maximum wire range Mains distribution system Power consumption Stand-by Max. ED indicators Material Safety Standards Classification Over voltage Approbation Protection Class Flammability Glow wire test EMC 0.75 to 2.5 mm2 T-S, 16A max, with eutral grounded 0.75W max. 0.75W max. See EDs and buttons PC-ABS According to ow Voltage Directive 2006/95/EC E/IEC amp control gear, Particular requirements for gear, Particular requirements for miscellaneous electronic circuits used with luminaires IEC uminaires, General requirements and tests Class I Category III Product complies with the relevant European Directive (CE) and KEMA IP20 U94-V C/30s According to EU EMC directive 2004/108/EC Compliance IEC (E) / Immunity ETSI E / Emission ETSI E / E Class B Weight R&TTE Applicable standard 0.15 kg According to Directive 1995/5/EC E V1.7.1

8 8/8 Sensor Material PC Battery type SAFT S Battery life See table Detection range See detection pattern ight sensor Maximum ight evel: 1000 ux at 50% reflection. Minimum ight evel: 200 ux at 10% reflection. Weight (with battery) Safety Standards EMC 0.10 kg According to ow Voltage Directive 2006/95/EC E/IEC amp control gear, Particular requirements for gear, Particular requirements for miscellaneous electronic circuits used with luminaires IEC uminaires, General requirements and tests According to EU EMC directive 2004/108/EC Compliance IEC (E) / Immunity ETSI E / Emission ETSI E / E Class B Occupancy timer R&TTE 1 to 30 minutes According to Directive 1995/5/EC Packing data Type Box dimensions Qty Material Weight (Kg) (mm) net gross RA1750/00 Wireless Universal Actuator 176 x 57 x 57 1 card board RM1763/00 Wireless MovDet + DO 83 x 83 x 24 1 card board CC1720/00 Wieland cable 320 x 240 x 12 1 plastic bag CC1723/00 St plug F cable MidEur 320 x 240 x 53 1 plastic bag CC1727/00 St plug E cable France 320 x 240 x 53 1 plastic bag Ordering Data Type MOQ Ordering number EA code level 1 EA code level 3 EOC RA1750/00 Wireless Universal Actuator RM1763/00 Wireless MovDet + DO CC1720/00 Wieland cable CC1723/00 St plug F cable MidEur CC1727/00 St plug E cable France /2010 Data subject to change

LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller

LRM2070, LRM2080, LRM2090 Datasheet OccuSwitch DALI sensor/controller 1/15 General description 80 The OccuSwitch DALI is a combined sensor and controller. It will dim and switch on the lights in a room or area on occupancy and available daylight, with options for local override,

More information

LRI1655, LLC1655 Datasheet ActiLume 1-10V System

LRI1655, LLC1655 Datasheet ActiLume 1-10V System 1/6 Product details The ActiLume 1-10 V luminaire-based sensor enables daylight regulation and dimming when no presence is detected. The delay time can be customized between 1 and 30 minutes. The ActiLume

More information

LCC1653/01, LRI1653/01 ActiLume DALI System

LCC1653/01, LRI1653/01 ActiLume DALI System 1/8 Product description The Philips ActiLume lighting control system consists of a small, lightweight sensor and controller, designed for easy integration into luminaires. ActiLume is a true Plug and Play

More information

UID8451, UID8461. Product guide. ZigBee Green Power switch and scene selector UID8451, UID8461. No wiring and power connections required so easy to

UID8451, UID8461. Product guide. ZigBee Green Power switch and scene selector UID8451, UID8461. No wiring and power connections required so easy to , UID8461 ZigBee Green Power family Product guide, UID8461 ZigBee Green Power switch and scene selector No wiring and power connections required so easy to install and maintenance free. Low mechanical

More information

Pro. LCN1840/05 Wireless gateway. Specification sheet. Connected lighting. Find out more about Interact

Pro. LCN1840/05 Wireless gateway. Specification sheet. Connected lighting. Find out more about Interact Pro LCN1840/05 Wireless gateway Specification sheet Works with Connected lighting Find out more about Interact www.interact-lighting.com LCN1840/05 The Interact Pro wireless gateway (WG) is the basis of

More information

As soon as the luminaires are switched off, the built-in relay disconnects the control gear from the mains supply, reducing power loss to 0.5 W.

As soon as the luminaires are switched off, the built-in relay disconnects the control gear from the mains supply, reducing power loss to 0.5 W. luxcotro smartdim Control with ambient light sensor/push to make switches/pir sensor Digital DSI sensor module for controlling 5 digital, electronic ballasts. By connecting a sensor, the connected /TE

More information

Allure EC-Smart-Comfort Series

Allure EC-Smart-Comfort Series Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview The Allure EC-Smart-Comfort series are versatile communicating sensor which provide

More information

Installation Guide. OB-1101 idim Orbit. 1. Features and Connections. Default Settings. Connections MANUAL SWITCH DALI 1 DALI 2 L2 L1

Installation Guide. OB-1101 idim Orbit. 1. Features and Connections. Default Settings. Connections MANUAL SWITCH DALI 1 DALI 2 L2 L1 Installation Guide OB-1101 idim Orbit The OB-1101 idim Orbit with single movement detector is a standalone, flush-mounted sensor that provides easy installation and configuration of lighting control applications.

More information

Electrical Actuators

Electrical Actuators OEM Electrical Actuators for valves VVP459..., VXP459..., VMP459..., VXG48, VXI48, VVG549 SSC319 SSC819 SSC319 operating voltage AC 230 V 3-position control signal SSC819 operating voltage AC 24 V 3-position

More information

Electrical Actuators

Electrical Actuators 4 891 SSB without auxiliary switch SSB1 with auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB31 SSB81 SSB61 SSB31 operating voltage AC 230

More information

Temperature Controller

Temperature Controller 2 728 Temperature Controller ultizone Floor Heating Systems RRV817 ultizone model with up to 7 zone outputs by combining 2 RRV817 controllers. Used for central control of underfloor heating systems in

More information

Electrical Actuators

Electrical Actuators 4 891 SSB without auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB1 with auxiliary switch SSB31 SSB61 SSB81 SSB31 operating voltage AC 230

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range

More information

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual HOBO Occupancy/Light Data Logger (UX90-005x/x) Manual UX90-005x The HOBO Occupancy/Light data logger monitors room occupancy up to 5 or 12 meters away (depending on the model) as well as indoor light changes

More information

Product and functional description

Product and functional description Product and functional description The instabus / DAI gateway 141 is a KX EIB device with one DAI output to which up to 64 DAI actuators (e.g. DAI ballasts) can be connected to. It is not allowed to connect

More information

Allure EC-Smart-Comfort Series

Allure EC-Smart-Comfort Series Datasheet Allure EC-Smart-Comfort Series Communicating sensors with Smart-Light and Smart-Blind add-on modules Overview Features & Benefits The Allure EC-Smart-Comfort Series are versatile communicating

More information

Rotary version, three-position control

Rotary version, three-position control 4 622 Residential Air damper actuators GXD..31.1 Rotary version, three-position control Electric motor-driven actuators for three-position control 1.5 Nm nominal torque AC 24 V or AC 230 V rated voltage

More information

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000 1 542 1542P03 1542P01 1542P02 QXA2001 QXA2000 AQX2000 Condensation Monitor QXA2000 QXA2001 The QXA2000 condensation monitor is used to avoid damage due to condensation on chilled ceilings and in HVAC plant.

More information

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

Airflow Pressure Sensor

Airflow Pressure Sensor Desigo TRA Airflow Pressure Sensor DXA.S04P1... Airflow Pressure Sensor (APS) is used to measure airflow for room pressurization and fume hood control applications. Differential Pressure (velocity) is

More information

Installation Guide DEVIlink CC Central Controller

Installation Guide DEVIlink CC Central Controller DEVIlink CC Central Controller www.devi.com Table of Contents 1 Introduction.................................... 4 2 Guidelines for installation....................... 5 3 Installation plan.................................

More information

ASI Systems ML5720A Series

ASI Systems ML5720A Series ML5720A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5720A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

Electrical actuators

Electrical actuators 4 893 SSA without auxiliary switch Electrical actuators SSA1 with auxiliary switch for radiator valves, MiniCombiValves (MCV) and small valves SSA31 SSA81 SSA61 Use SSA31 operating voltage AC 230 V 3-position

More information

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual

HOBO Occupancy/Light Data Logger (UX90-005x/-006x) Manual HOBO Occupancy/Light Data Logger (UX90-005x/x) Manual UX90-005x The HOBO Occupancy/Light data logger monitors room occupancy up to 5 or 12 meters away (depending on the model) as well as indoor light changes

More information

basicdim Wireless Wireless module for basicdim

basicdim Wireless Wireless module for basicdim Wireless Wireless module for Product description Wireless controllable with a Android / ios smart device o need for an external gateway device Forms automatically a wireless communication network with

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 641 DESIGO RX Room unit with PPS2 interface for use with: QAX321 devices of the ranges DESIGO RXC, RXB, and RXA (PPS2) DESIGO PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005 Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program

More information

ASI Systems ML5740A Series

ASI Systems ML5740A Series ML5740A Series Electric Linear Valve Actuators Non-Spring Return APPLICATION The ML5740A series actuators operate standard ASI Systems valves in heating, ventilating and air conditioning (HVAC) applications.

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B 3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled

More information

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates 1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for

More information

Heating Circuit Controller

Heating Circuit Controller 2 706 Synco living Heating Circuit Controller RRV918 RF-controlled heating circuit controller for up to 8 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

PAR-WT50R-E PAR-WR51R-E

PAR-WT50R-E PAR-WR51R-E Wireless Remote Controller and Receiver PAR-WT50R-E PAR-WR51R-E This manual explains installation of the PAR-WR51R-E wireless receiver and the PAR-WT50R-E wireless remote controller, and settings of these

More information

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U) (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET TCY-BH-T-U Wall controller with sensor TDC-BH-T-U Duct controller with sensor SOA-Tn10 Outdoor temperature sensor (Optional) OVERVIEW For wall applications

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

Electromotoric actuators

Electromotoric actuators 4 893 SSA.. without auxiliary switch ACVATIX Electromotoric actuators SSA.. with auxiliary switch For radiator valves, MiniCombiValves (MCV) and small valves SSA3.. SSA8.. SSA6.. Use SSA3.. operating voltage

More information

Fixture-Integrated Sensor based on Bluetooth mesh

Fixture-Integrated Sensor based on Bluetooth mesh Fixture-Integrated Sensor based on Bluetooth mesh Converts uminaires into Multifunctional IoT Devices Bluetooth mesh 0-10V Dimming Control Motion Sensor Fixture Integration Ambient ight Sensor Autonomous

More information

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,

More information

Heating Circuit Controller

Heating Circuit Controller 2 705 Synco 900 Heating Circuit Controller RRV912 RF-controlled heating circuit controller for up to 2 heating circuits RF communication based on KNX standard (868 MHz, bidirectional) Connection facility

More information

effi ciency intelligence easiness idim Sense & Solo User Manual People Innovations Solutions

effi ciency intelligence easiness idim Sense & Solo User Manual People Innovations Solutions effi ciency intelligence easiness & Solo User Manual People Innovations Solutions 1. Introduction idim idim Family Introduction The idim concept is a luminaire based lighting control solution prising an

More information

HOBO Light On/Off Data Logger (UX90-002x) Manual

HOBO Light On/Off Data Logger (UX90-002x) Manual Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com HOBO Light On/Off Data Logger (UX90-002x) Manual The HOBO Light On/Off data logger monitors indoor light

More information

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information

Siemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information Gamma instabus Technical Product Information RL 513D23 Switching actuator (relay), 3 x 6A 5WG1 513-4DB23 Switching actuator for independent switching of three lighting luminaire groups or other loads one

More information

Non-communicating room controllers

Non-communicating room controllers 3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For

More information

AEW Pulse Adapter. Building Technologies

AEW Pulse Adapter. Building Technologies 5 383 Pulse Adapter AEW310.2 The AEW310.2 pulse adapter acquires and handles the pulses from 1 or 2 consumption meters with pulse output and transmits the data to an M-Bus-network. For setting the parameters,

More information

252F 5WG FB_1 DELTA

252F 5WG FB_1 DELTA Product DELTA i-system DELTA profil Fan-Coil Unit Operator Panels Hotel titanium white 5WG1 237-2FB11 pearl grey 5WG1 252-2FB01 carbon metallic 5WG1 237-2FB21 titanium white 5WG1 252-2FB11 aluminum metallic

More information

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates 1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal

More information

Product and Application Description

Product and Application Description Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

Communication module to connect M-bus devices to POL6xx.xxx controllers.

Communication module to connect M-bus devices to POL6xx.xxx controllers. s 3 936 Climatix TM Climatix communication M-Bus module POL907.00/xxx Communication module to connect M-bus devices to POL6xx.xxx controllers. The POL907.00/xxx communication module offers the following

More information

C5S120 Installation and Connection Guide

C5S120 Installation and Connection Guide C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet NVK4A-SR-PC Modulating globe valve actuator for -way and 3-way globe valves Actuating force 000 N Nominal voltage AC/DC 4 V Control: modulating DC (0) V...0 V Nominal stroke 0 mm Design

More information

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300.

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300. Indoor Stand-Alone Access Point SunSpot AC00 and SunSpot N300 The SunSpot N300 and the SunSpot AC00 are single- and dual-band concurrent access points (AP s) respectively. The units are designed to be

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

7-day room temperature controller

7-day room temperature controller s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large

More information

Installation and User Guide. idim Remote Control (304) Product description

Installation and User Guide. idim Remote Control (304) Product description Installation and User Guide idim Remote Control (0) Product description The idim Remote Control (0) can be used with the idim Sense Standalone to modify the preset light levels and recall/ store scenes,

More information

1. Safety instructions

1. Safety instructions AX-904 1. Safety instructions Failure to follow the instructions listed below may cause personal injury. Read and understand all instructions prior to any operation. Do not remove any label from the tool.

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

Self-Adjusting Ultrasonic Wall Switch Sensor

Self-Adjusting Ultrasonic Wall Switch Sensor -1 06.09.05 Self-Adjusting Ultrasonic Switch Sensor The ultrasonic offers a direct and quick replacement of wall switches for stand-alone line voltage switching of small spaces. The intelligent, continuously

More information

HOBO Motor On/Off Data Logger (UX90-004x) Manual

HOBO Motor On/Off Data Logger (UX90-004x) Manual HOBO Motor On/Off Data Logger (UX90-004x) Manual The HOBO Motor On/Off data logger records motor on and off conditions by detecting the AC magnetic fields given off by a rotating motor using its internal

More information

HOBO State Data Logger (UX90-001x) Manual

HOBO State Data Logger (UX90-001x) Manual HOBO State Data Logger (UX90-001x) Manual The HOBO State/Pulse/Event/Runtime data logger records state changes, electronic pulses and mechanical or electrical contact closures from external sensing devices.

More information

ERF910. RF Repeater. Synco living

ERF910. RF Repeater. Synco living 2 704 Synco living RF Repeater ERF910 Wireless RF repeater for extending plant RF communication based on KNX standard (868 MHz, bidirectional) Mains-powered AC 2 V (with external power pack) Use For integration

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

Display Panel BAT 100 LSN. en Operation Guide

Display Panel BAT 100 LSN. en Operation Guide Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance

More information

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time. Datasheet Shades / Sunblinds Expansion Modules Overview Applications 100-240 VAC shades / sunblinds 24 VDC shades / sunblinds The Expansion Modules are microprocessor-based interfaces that extend the number

More information

HBT01 HBT02 Built-in Detachable Version

HBT01 HBT02 Built-in Detachable Version Synchrony ighting Control With Wireless Technology HBT01 HBT02 Built-in Detachable Version Applications The freedom of wireless mesh networks configured by smartphone APP s considerably changes the approach

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O s 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

NookBox Installation Guide Camera IR Pet Detector. Installation Guide. NookBox Camera IR Pet Detector (P / E )

NookBox Installation Guide Camera IR Pet Detector. Installation Guide. NookBox Camera IR Pet Detector (P / E ) 1 Installation Guide NookBox Camera IR Pet Detector (P119021 / E6309669) 2 NookBox Camera IR Pet Detector (P119021 / E6309669) NookBox Camera IR Pet Detector is a passive infrared (PIR) motion sensor camera.

More information

Air damper actuators

Air damper actuators 4 604 OpenAir Air damper actuators Rotary version, AC/DC 24 V and AC 230 V GQD...1 GQD 1 Electric motor-driven actuators for two-position and three-position control as well as DC 0 10 V control 2 Nm nominal

More information

MOVEMENT DETECTOR WITH INBUILT CAMERA USER GUIDE

MOVEMENT DETECTOR WITH INBUILT CAMERA USER GUIDE Easy to install wireless technology MOVEMENT DETECTOR WITH INBUILT CAMERA USER GUIDE www.my-serenity.ch What s in the Box? 1 x Wireless Movement Detector with inbuilt camera (also called PIRCAM or PIR

More information

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A Z-Wave Ceiling-mount Smoke Detector Copyright Z-Wave Ceiling-mount Smoke Detector Copyright 2015 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted,

More information

Power supply module, bus connection module

Power supply module, bus connection module s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can

More information

Temperature controller Ducted systems

Temperature controller Ducted systems 2 725 Temperature controller Ducted systems Standard model without zoning functions RRV851 Multifunctional controller used for central control of ducted HVAC systems in combination with a QAX850 master

More information

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700

RMZ792. Bus Operator Unit. Building Technologies HVAC Products. Synco 700 3 113 Synco 700 Bus Operator Unit RMZ792 Communicating operator unit for operating up to 150 controllers, room units and central units from the Synco 700 range via Konnex bus. Favorite pages can be freely

More information

EYE 200: DDC single-room controller, ecos200

EYE 200: DDC single-room controller, ecos200 Product data sheet 94.200 EYE 200: DDC single-room controller, ecos200 How energy efficiency is improved Individual unitary control, fan coil units, chilled-beam control system, etc. Features Part of the

More information

Overview of types. Technical data

Overview of types. Technical data echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control

More information

EVO-TM2A EVO-TM2B Touch Screen Monitor

EVO-TM2A EVO-TM2B Touch Screen Monitor User Manual Revision v1.3 Dec. 2010 EVO-TM2A EVO-TM2B Touch Screen Monitor Copyright 2010 August All Rights Reserved Manual Version 1.3 Part Number: The information contained in this document is subject

More information

Programmable controller MCX152V

Programmable controller MCX152V MAKIG MODER IVIG POSSIBE Technical brochure Programmable controller MCX152V MCX152V is a standard MCX electronic controller that stands on the top of MCX range thanks to its large number of input and output

More information

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use s 3 146 Synco 700 Universal Modules RMZ78 Extension modules for use with controls of the Synco 700 family. Use For heating, ventilation, air conditioning and chilled water plant equipped with controls

More information

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V 4 666 OpenAir TM Air damper actuators Linear version, modulating, AC 24 V GBB16...2 Electromotive linear actuators, DC 0...10 V modulating control signal, nominal force 440 N, operating voltage AC 24 V,

More information

TA18 active subwoofer. user manual

TA18 active subwoofer. user manual TA18 active subwoofer user manual Musikhaus Thomann e.k. Treppendorf 30 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 email: info@thomann.de Internet: www.thomann.de 30.11.2011 Table of contents

More information

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100 Mid-span 802.3af PoE Injector Installation Guide KPOE-100 Doc. 070521 1 (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used

More information

User Manual MagniLink One

User Manual MagniLink One User Manual MagniLink One LVI Low Vision International Verkstadsgatan 5 Tel: +46 470-727700 info@lvi.se SE-352 46 Växjö Faks: +46 470-727725 www.lvi.se Table of Contents 1 About LVI... 5 2 Introduktion

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

Product and functional description

Product and functional description Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A Copyright Z-Wave 4-in-1 Multi Sensor Copyright 2015 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system,

More information

TALON Network Manager- 2 & 6 Express

TALON Network Manager- 2 & 6 Express Technical Specification Sheet October 30, 2010 TALON Network Manager- 2 & 6 Express Description The TALON Network Manager-2 & 6 Express (TNM-2 XPR and TNM-6 XPR) is an embedded controller/server platform

More information

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time. Datasheet Lighting Expansion Modules Overview Applications On/Off lighting 1-10 V dimming lighting The Expansion Modules are microprocessor-based interfaces that extend the number of inputs and outputs

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N

Product and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial

More information

Data sheet. Function description. Benefits

Data sheet. Function description. Benefits Function description To permit direct communication with the Philips SR interface, we offer two of our best and most innovative sensors: the ED PIR sensor with its patented multi-segment sensor lens and

More information

INTRODUCTION CT87E FEATURES AND CONTROLS

INTRODUCTION CT87E FEATURES AND CONTROLS INTRODUCTION The CT87E is a precision instrument used to monitor and record the presence or absence of voltage, light, or sound level such as what would be produced by an operating electric motor or compressor.

More information

Electromotoric actuators

Electromotoric actuators 4 861 ACVATIX Electromotoric actuators for Combi-valve types VPI45.., DN15 32 SSD31.. SSD81.. SSD61.. SSD31.. operating voltage AC 230 V 3-position control signal SSD81.. operating voltage AC 24 V 3-position

More information

Cheetah Light LLC. (214) Instruction Manual

Cheetah Light LLC.  (214) Instruction Manual CL-80 Cheetah Light LLC. www.cheetahstand.com info@cheetahstand.com ()7-98 Instruction Manual FOREWORD Before using this product Please read this user manual carefully in order to ensure your safety and

More information

HOBO State Data Logger (UX90-001x) Manual

HOBO State Data Logger (UX90-001x) Manual HOBO State Data Logger (UX90-001x) Manual The HOBO State/Pulse/Event/Runtime data logger records state changes, electronic pulses and mechanical or electrical contact closures from external sensing devices.

More information

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3.

USER MANUAL. RC-43SL 6-Button Room Controller MODEL: P/N: Rev 3. USER MANUAL MODEL: RC-43SL 6-Button Room Controller P/N: 2900-300450 Rev 3 www.kramerav.com Contents 1 Introduction 1 2 Getting Started 2 2.1 Achieving the Best Performance 2 2.2 Safety Instructions

More information