Data Reference Manual

Size: px
Start display at page:

Download "Data Reference Manual"

Transcription

1 Machine Automation Controller NX-series Data Reference Manual NX- W525-E1-06

2 NOTE All rights reserved. No part this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical, electronic, photocopying, recording, or otherwise, without the prior written permission OMRON. No patent liability is assumed with respect to the use the information contained herein. Moreover, because OMRON is constantly striving to improve its high-quality products, the information contained in this manual is subject to change without notice. Every precaution has been taken in the preparation this manual. Nevertheless, OMRON assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use the information contained in this publication. Trademarks Sysmac and SYSMAC are trademarks or registered trademarks OMRON Corporation in Japan and other countries for OMRON factory automation products. Microst, Windows, Windows Vista, Excel, and Visual Basic are either registered trademarks or trademarks Microst Corporation in the USA and other countries. EtherCAT is registered trademark and patented technology, licensed by Beckhf Automation GmbH, Germany. Safety over EtherCAT is registered trademark and patented technology, licensed by Beckhf Automation GmbH, Germany. ODVA, CIP, CompoNet, DeviceNet, and EtherNet/IP are trademarks ODVA. The SD and SDHC logos are trademarks SD-3C, LLC. Other company names and product names in this document are the trademarks or registered trademarks their respective companies. Copyrights Microst product screen shots reprinted with permission from Microst Corporation.

3 Introduction Introduction Thank you for purchasing an NX-series. This manual lists data that is required to configure systems, such as the s and weights the s that configure Slave Terminals. Use this manual when considering the Unit configuration Slave Terminals on paper. Keep this manual in a safe place where it will be available for reference during operation. Intended Audience This manual is intended for the following personnel, who must also have knowledge electrical systems (an electrical engineer or the equivalent). Personnel in charge introducing FA systems. Personnel in charge designing FA systems. Personnel in charge installing and maintaining FA systems. Personnel in charge managing FA systems and facilities. For programming, this manual is intended for personnel who understand the programming language specifications in international standard IEC or Japanese standard JIS B Applicable Products This manual covers the following product. NX-series Communications Coupler Units EtherCAT Coupler Unit Digital Units Analog Units Position Interface Units System Units Safety Control Units Communications Interface Units 1

4 CONTENTS CONTENTS Introduction...1 Intended Audience... 1 Applicable Products... 1 Relevant Manuals...4 Manual Structure...6 Page Structure and Icons... 6 Special Information... 7 Precaution on Terminology... 7 Terms and Conditions Agreement...8 Warranty, Limitations Liability... 8 Application Considerations... 9 Disclaimers... 9 Safety Precautions...10 Precautions for Safe Use Precautions for Correct Use...12 Regulations and Standards...13 Related Manuals...14 Revision History...17 Sections in this Manual...19 Section 1 Data List 1-1 How to Read the Data List Communications Coupler Units EtherCAT Coupler Unit EtherNet/IP Coupler Unit Digital Units Digital Input Units Digital Output Units Digital Mixed Units Analog Units Analog Input Units Analog Output Units Temperature Input Units Position Interface Units Incremental Encoder Input Units SSI Input Units Pulse Output Units Communications Interface Units System Units Additional Power Supply Unit Additional Power Supply Unit

5 CONTENTS Power Supply Connection Unit Shield Connection Unit Safety Control Units Safety CPU Unit Safety Input Units Safety Output Units Appendices A-1 Power Supply and Power Supply Capacity...A-2 A-1-1 EtherCAT Coupler Unit...A-2 A-1-2 EtherNet/IP Coupler Unit...A-3 A-1-3 Additional Power Supply Unit...A-4 A-2 List Screwless Clamping Terminal Block s...a-5 A-2-1 Notation...A-5 A-2-2 List Terminal Block s...a-5 A-2-3 Applicable Screwless Clamping Terminal Blocks for Each Unit...A-6 A-3 Version Information...A-8 A-3-1 Relationship between Unit Versions Units...A-8 A-3-2 Support Functions the Communications Coupler Units and Restrictions on the s...a-15 3

6 Relevant Manuals Relevant Manuals To use the NX-series, you must refer to the manuals for all related products. Read all the manuals that are relevant to your system configuration and application before you use the NX-series. Most operations are performed from the Sysmac Studio Automation Stware. Refer to the Sysmac Studio Version 1 Operation Manual (Cat. No. W504) for information on the Sysmac Studio. NX Series NJ/NX Series Communications Coupler Unit s All Units NX-series Data Reference Manual NX-series Safety Control Unit User s Manual NX-series Position Interface Units User's Manual NX-series System Units User's Manual NX-series Analog Units User's Manual NX-series Digital Units User's Manual NX-series EtherNet/IP Coupler Unit User's Manual NX-series EtherCAT Coupler Unit User's Manual NJ/NX-series Troubleshooting Manual NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual NJ/NX-series CPU Unit Motion Control User's Manual NJ/NX-series CPU Unit Stware User's Manual NJ/NX-series CPU Unit Hardware User's Manuals Learning about the NX-series Units Specifications Functionality Application procedures Learning about Slave Terminals Slave Terminal specifications System configuration Rules on building systems Slave Terminal application procedures Slave Terminal installation procedures Support Stware connection procedures Procedure to estimate Slave Terminal performance Procedures for using safety control systems with Slave Ter- minals Procedures for estimating performance safety control systems with Slave Ter- minals 4

7 Relevant Manuals NX Series NJ/NX Series Communications Coupler Unit s All Units NX-series Data Reference Manual NX-series Safety Control Unit User s Manual NX-series Position Interface Units User's Manual NX-series System Units User's Manual NX-series Analog Units User's Manual NX-series Digital Units User's Manual NX-series EtherNet/IP Coupler Unit User's Manual NX-series EtherCAT Coupler Unit User's Manual NJ/NX-series Troubleshooting Manual NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual NJ/NX-series CPU Unit Motion Control User's Manual NJ/NX-series CPU Unit Stware User's Manual NJ/NX-series CPU Unit Hardware User's Manuals Using NX-series Units with NJ/NX-series Controllers Using a Slave Terminal connected to the built-in EtherCAT port on an NJ/NX-series CPU Unit Procedures for performing motion control with Position Interface Units Troubleshooting Managing errors for the overall NJ/NX-series Controller Troubleshooting Slave Terminals and Communications Coupler Units Troubleshooting NX Units Performing Unit maintenance Referencing data lists for s, weights, etc. 5

8 Manual Structure Manual Structure Page Structure and Icons The following page structure and icons are used in this manual. Level 2 heading Level 3 heading Level 1 heading Level 2 heading Level 3 heading Gives the current headings. A step in a procedure Indicates a procedure. Page tab Gives the number the main section. Special information Icons indicate precautions, additional information, or reference information. Manual name Note This illustration is provided only as a sample. It may not literally appear in this manual. 6

9 Manual Structure Special Information Special information in this manual is classified as follows: Precautions for Safe Use Precautions on what to do and what not to do to ensure safe usage the product. Precautions for Correct Use Precautions on what to do and what not to do to ensure proper operation and performance. Additional Information Additional information to read as required. This information is provided to increase understanding or make operation easier. Version Information Information on differences in specifications and functionality for CPU Units and Communications Coupler Units with different unit versions and for different versions the Sysmac Studio is given. Note References are provided to more detailed or related information. Precaution on Terminology In this manual, download refers to transferring data from the Sysmac Studio to the physical Controller and upload refers to transferring data from the physical Controller to the Sysmac Studio. For the Sysmac Studio, synchronization is used to both upload and download data. Here, synchronize means to automatically compare the data for the Sysmac Studio on the computer with the data in the physical Controller and transfer the data in the direction that is specified by the user. In this manual, the directions in relation to the Units are given in the following figure, which shows upright installation. Up Left Right Down 7

10 Terms and Conditions Agreement Terms and Conditions Agreement Warranty, Limitations Liability Warranties Exclusive Warranty Omron s exclusive warranty is that the Products will be free from defects in materials and workmanship for a period twelve months from the date sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. Limitations OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility any type for claims or expenses based on infringement by the Products or otherwise any intellectual property right. Buyer Remedy Omron s sole obligation hereunder shall be, at Omron s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement there) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron s analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See or contact your Omron representative for published information. Limitation on Liability; Etc OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CON- SEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability Omron Companies exceed the individual price the Product on which liability is asserted. 8

11 Terms and Conditions Agreement Application Considerations Suitability Use Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination the Product in the Buyer s application or use the Product. At Buyer s request, Omron will provide applicable third party certification documents identifying ratings and limitations use which apply to the Product. This information by itself is not sufficient for a complete determination the suitability the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness the particular Product with respect to Buyer s application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products Omron Companies shall not be responsible for the user s programming a programmable Product, or any consequence there. Disclaimers Performance Data Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result Omron s test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron s Warranty and Limitations Liability. Change in Specifications Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron s representative at any time to confirm actual specifications purchased Product. Errors and Omissions Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proreading errors or omissions. 9

12 Safety Precautions Safety Precautions Refer to the user's manual for the Unit to be used for safety precautions. 10

13 Precautions for Safe Use Precautions for Safe Use Refer to the user's manual for the Unit to be used for precautions for safe use. 11

14 Precautions for Correct Use Precautions for Correct Use Refer to the user's manual for the Unit to be used for precautions for correct use. 12

15 Regulations and Standards Regulations and Standards Refer to the user's manual for the Unit to be used for regulations and standards. 13

16 Related Manuals Related Manuals The following table shows related manuals. Use these manuals for reference. Manual name Cat. No. numbers Application Description NX-series Data Reference Manual NX-series Digital Units User s Manual NX-series Analog Units User s Manual NX-series System Units User s Manual NX-series Position Interface Units User s Manual NX-series Communications Interface Units User s Manual NX-series Safety Control Unit User s Manual NX-series Safety Control Unit Instructions Reference Manual Sysmac Studio Version 1 Operation Manual W525 NX- Referencing lists the data that is required to configure systems with NX-series Units W521 NX-ID Learning how to NX-IA use NX-series Digital NX-OC Units NX-OD NX-MD W522 NX-AD Learning how to NX-DA use NX-series NX-TS Analog Units and Temperature Input Units W523 NX-PD1 Learning how to NX-PF0 use NX-series NX-PC0 System Units NX-TBX01 W524 NX-EC0 Learning how to NX-ECS use NX-series NX-PG0 Position Interface Units W540 NX-CIF Learning how to use NX-series Communications Interface Units Z930 NX-SL Learning how to NX-SI use NX-series NX-SO Safety Control Units Z931 NX-SL Learning about the specifications instructions for the Safety CPU Unit. W504 SYSMAC- SE2 Learning about the operating procedures and functions the Sysmac Studio. Lists the s, weights, and other data that is required to configure systems with NX-series Units are provided. The hardware, setup methods, and functions the NX-series Digital Units are described. The hardware, setup methods, and functions the NX-series Analog Units and Temperature Input Units are described. The hardware and functions the NX-series System Units are described. The hardware, setup methods, and functions the NX-series Incremental Encoder Input Units, SSI Input Units, and Pulse Output Unit are described. The hardware, setup methods, and functions the NX-series Communications Interface Units are described. The hardware, setup methods, and functions the NX-series Safety Control Units are described. The instructions for the Safety CPU Unit are described. When programming, use this manual together with the NX-series Safety Control Unit User s Manual (Cat. No. Z930). Describes the operating procedures the Sysmac Studio. 14

17 Related Manuals Manual name Cat. No. numbers Application Description W503 NX701- NJ501- NJ301- NJ101- Learning about the errors that may be detected in an NJ/NX-series Controller. NJ/NX-series Troubleshooting Manual NX-series EtherCAT Coupler Unit User s Manual NX-series Ether- Net/IP TM Coupler Unit User s Manual NX-series CPU Unit Hardware User s Manual NJ-series CPU Unit Hardware User s Manual W519 NX-ECC20 Learning how to use an NX-series EtherCAT Coupler Unit and Ether- CAT Slave Terminals W536 NX-EIC202 Learning how to use an NX-series EtherNet/IP Coupler Unit and EtherNet/IP Slave Terminals. W535 NX701- Learning the basic specifications the NX-series CPU Units, including introductory information, designing, installation, and maintenance. Mainly hardware information is provided. W500 NJ501- NJ301- NJ101- Learning the basic specifications the NJ-series CPU Units, including introductory information, designing, installation, and maintenance. Mainly hardware information is provided. Concepts on managing errors that may be detected in an NJ/NX-series Controller and information on individual errors are described. Use this manual together with the NJ-series CPU Unit Hardware User's Manual (Cat. No. W500) or NX-series CPU Unit Hardware User's Manual (Cat. No. W535) and with the NJ/NX-series CPU Unit Stware User's Manual (Cat. No. W501). The following items are described: the overall system and configuration methods an EtherCAT Slave Terminal (which consists an NX-series Ether- CAT Coupler Unit and s), and information on hardware, setup, and functions to set up, control, and monitor s through EtherCAT. The following items are described: the overall system and configuration methods an EtherNet/IP Slave Terminal (which consists an NX-series Ether- Net/IP Coupler Unit and s), and information on hardware, setup, and functions to set up, control, and monitor s. An introduction to the entire NX-series system is provided along with the following information on the CPU Unit. Features and system configuration Overview Part names and functions General specifications Installation and wiring Maintenance and Inspection Use this manual together with the NJ/NX-series CPU Unit Stware User's Manual (Cat. No. W501). An introduction to the entire NJ-series system is provided along with the following information on the CPU Unit. Features and system configuration Overview Part names and functions General specifications Installation and wiring Maintenance and Inspection Use this manual together with the NJ/NX-series CPU Unit Stware User's Manual (Cat. No. W501). 15

18 Related Manuals Manual name Cat. No. numbers Application Description NJ/NX-series CPU Unit Stware User's Manual W501 NX701- NJ501- Learning how to program and set The following information is provided on an NJ/NX-series CPU Unit. up an NJ301- CPU Unit operation NJ/NX-series CPU NJ101- CPU Unit features Unit. Mainly stware information is provided. Initial settings Programming based on IEC language specifications Use this manual together with the NJ-series CPU Unit Hardware User's Manual (Cat. No. W500) or NX-series CPU Unit Hardware User's Manual (Cat. No. W535). NJ/NX-series CPU Unit Built-in EtherCAT Port User's Manual NJ/NX-series CPU Unit Motion Control User's Manual NJ/NX-series Instructions Reference Manual NJ/NX-series Motion Control Instructions Reference Manual W505 W507 W502 W508 NX701- NJ501- NJ301- NJ101- NX701- NJ501- NJ301- NJ101- NX701- NJ501- NJ301- NJ101- NX701- NJ501- NJ301- NJ101- Using the built-in EtherCAT port on an NJ/NX-series CPU Unit. Learning about motion control settings and programming concepts. Learning detailed specifications on the basic instructions an NJ/NX-series CPU Unit. Learning about the specifications the motion control instructions. Information on the built-in EtherCAT port is provided. This manual provides an introduction and provides information on the configuration, features, and setup. Use this manual together with the NJ-series CPU Unit Hardware User's Manual (Cat. No. W500) or NX-series CPU Unit Hardware User's Manual (Cat. No. W535) and with the NJ/NX-series CPU Unit Stware User's Manual (Cat. No. W501). The settings and operation the CPU Unit and programming concepts for motion control are described. When programming, use this manual together with the NJ-series CPU Unit Hardware User's Manual (Cat. No. W500) or NX-series CPU Unit Hardware User's Manual (Cat. No. W535) and with the NJ/NX-series CPU Unit Stware User's Manual (Cat. No. W501). The instructions in the instruction set (IEC specifications) are described. When programming, use this manual together with the NJ-series CPU Unit Hardware User's Manual (Cat. No. W500) or NX-series CPU Unit Hardware User's Manual (Cat. No. W535) and with the NJ/NX-series CPU Unit Stware User's Manual (Cat. No. W501). The motion control instructions are described. When programming, use this manual together with the NJ-series CPU Unit Hardware User's Manual (Cat. No. W500) or NX-series CPU Unit Hardware User's Manual (Cat. No. W535), with the NJ/NX-series CPU Unit Stware User's Manual (Cat. No. W501), and with the NJ/NX-series CPU Unit Motion Control User's Manual (Cat. No. W507). 16

19 Revision History Revision History A manual revision code appears as a suffix to the catalog number on the front and back covers the manual. Cat. No. W525-E1-06 Revision code Revision code Date Revised content 01 April 2013 Original production 02 June 2013 Added models on time stamp refreshing. Added Safety Control Units. Corrected mistakes. 03 September 2013 Added new models and made changes accompanying the upgrade to the unit version in September Corrected mistakes. 04 July 2014 Added new models in July December 2014 Made changes accompanying the addition the EtherNet/IP Coupler Units. 06 April 2015 Added new models and made changes accompanying the upgrade to the unit version in April

20 Revision History 18

21 Sections in this Manual Sections in this Manual 1 1 A Data List Appendices A 9 19

22 Sections in this Manual 20

23 1 1 Data List This section provides the data lists for Communications Coupler Units and s. 1-1 How to Read the Data List Communications Coupler Units EtherCAT Coupler Unit EtherNet/IP Coupler Unit Digital Units Digital Input Units Digital Output Units Digital Mixed Units Analog Units Analog Input Units Analog Output Units Temperature Input Units Position Interface Units Incremental Encoder Input Units SSI Input Units Pulse Output Units Communications Interface Units System Units Additional Power Supply Unit Additional Power Supply Unit Power Supply Connection Unit Shield Connection Unit Safety Control Units Safety CPU Unit Safety Input Units Safety Output Units

24 1 Data List 1-1 How to Read the Data List This data list is described with the following format. Example: For Digital Input Units [W] Current from Unit configuration data Input current metho d Wei ght [g] Width [mm] data size [byte] Number entry mappings Num ber poin ts Summary specifications Intern al comm on Rated input voltage refres hing metho d ON/OFF respons e time The items for this format are explained below. Unit Configuration Data The Unit configuration data is the data required to create the Unit configuration Slave Terminal. Create the Unit configuration so that the total value the data for which the maximum value is defined does not exceed the maximum value the Slave Terminal. Refer to the user's manual for the Communications Coupler Unit on the maximum value for each data. Item Current from Input current method Description The the the Unit. The current from the Unit. The load current any external connection load, the input current the Input Units, and the current any connected external devices are not included. The input current the Unit at the rated voltage. Only the DC Input Units and AC Input Units have this item. The method for ing for the Unit. The method depends on each Unit. The is supplied from the NX bus or the external source. NX bus: Supply from the NX bus External: Supply from external source The Communications Coupler Unit and the Additional Power Supply Unit do not have this item. Weight The weight the Unit. Width The width the Unit. The unit is "mm". data size The data size default value that the Unit consumes. The unit is byte. However, the unit is bit for some Digital Units. In this case, the unit is given in the table. It is described according to the input/output sequence. Number entry mappings It is described according to the input/output sequence. The number entry mappings default value that the Unit consumes. Number cyclic communications connections *1 The maximum number connections that can be set by Class 1 messages. *1. This item is only for EtherNet/IP Coupler Units. 1-2

25 1 Data List Summary Specifications The summary specifications the Units to configure the Slave Terminal. Use this as a guide to select the Unit model when you consider the Unit configuration. The items in the Summary Specifications depend on the Unit type. The meaning each item is explained for each Unit type. 1-1 How to Read the Data List 1 1-3

26 1 Data List 1-2 Communications Coupler Units This section describes the data for Communications Coupler Units EtherCAT Coupler Unit Items in the Summary Specifications Item Description Unit Rated voltage The rated voltage the Unit that is supplied to the Unit. The amount that the Unit can to the s. capacity Rated voltage The rated voltage the that is supplied to the Unit. Maximum current The maximum value the current supplied from the that the Unit can to the s through the NX bus connectors. Data List [W] Current from Unit configuration data Weigh t [g] Width [mm] data size [byte] NX-ECC /0 NX-ECC NX-ECC /0 Number entry mappings Summary specifications Unit Rated voltage capacity *1 2/0 24 VDC 10 W max. Rated voltage 5 to 24 VDC Maximum current *1 *1. The capacity and the maximum current are sometimes restricted by conditions such as the temperature or installation orientation. For details, refer to A-1 Power Supply and Power Supply Capacity on page A-2. 4 A 10 A 1-4

27 1 Data List EtherNet/IP Coupler Unit Items in the Summary Specifications Data List Item Description Unit Rated voltage The rated voltage the Unit that is supplied to the Unit. The amount that the Unit can to the s. capacity Rated voltage The rated voltage the that is supplied to the Unit. [W] Current from Maximum current Unit configuration data Weigh t [g] NX-EIC Width [mm] data size [byte] 1 to 504 The maximum value the current supplied from the that the Unit can to the s through the NX bus connectors. Number cyclic communications connections Summary specifications Unit Rated voltage capacity * VDC 10 W max. Rated voltage 5 to 24 VDC Maximum current *1 *1. The capacity and the maximum current are sometimes restricted by conditions such as the temperature or installation orientation. For details, refer to A-1 Power Supply and Power Supply Capacity on page A A 1-2 Communications Coupler Units EtherNet/IP Coupler Unit 1-5

28 1 Data List 1-3 Digital Units This section describes the data for Digital Units Digital Input Units DC Input Units (Screwless Clamping Terminal Block, 12 mm Width) Items in the Summary Specifications Item Number points Internal common Rated input voltage refreshing method The number input points provided by the Unit. Description This is the polarity that the Unit uses to connect to input devices. There are models with NPN and PNP connections. The rated input voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and input refreshing with input changed time are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Changed time: Input refreshing with input changed time The delay time for which the status change the input terminals reaches the internal circuit the Unit. The input filter time is not included. It is described according to the ON/OFF sequence. 1-6

29 1 Data List Data List [W] Current from NX-ID No Unit configuration data Input current metho d Wei ght [g] Width [mm] data size [byte] 6 NX bus /0 bits Num ber poin ts 1/0 4 point s Summary specifications Number entry mappings Internal common NPN Rated input voltage 12 to 24 VDC refres hing metho d NX-ID NX-ID /0 VDC Chang ed time NX-ID No 6 4/0 PNP bits 12 to 24 VDC ON/OFF respons e time Sync 20/400 μs max. 100/ 100 ns max. Sync 20/400 μs max. NX-ID / NX-ID /0 VDC Chang ed time 100 ns max. NX-ID No 2/0 8 NPN Sync 20/400 NX-ID4442 point s PNP μs max. NX-ID NPN NX-ID5442 point s PNP 1-3 Digital Units Digital Input Units 1-7

30 1 Data List DC Input Units (M3 Screw Terminal Block, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Rated input voltage refreshing method The number input points provided by the Unit. Description This is the polarity that the Unit uses to connect to input devices. There are models with NPN and PNP connections. The rated input voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and input refreshing with input changed time are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Changed time: Input refreshing with input changed time The delay time for which the status change the input terminals reaches the internal circuit the Unit. The input filter time is not included. It is described according to the ON/OFF sequence. Data List [W] Current from NX-ID No Unit configuration data Input current metho d 7 External Wei ght [g] Width [mm] data size [byte] Num ber poin ts /0 1/0 16 point s Summary specifications Number entry mappings Internal common For both NPN/P NP Rated input voltage 24 VDC refres hing metho d ON/OFF respons e time Sync 20/400 μs max. 1-8

31 1 Data List DC Input Units (MIL Connector, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Rated input voltage refreshing method ON/OFF response time The number input points provided by the Unit. Description This is the polarity that the Unit uses to connect to input devices. There are models with NPN and PNP connections. The rated input voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and input refreshing with input changed time are available. In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Changed time: Input refreshing with input changed time The delay time for which the status change the input terminals reaches the internal circuit the Unit. The input filter time is not included. It is described according to the ON/OFF sequence. 1-3 Digital Units Digital Input Units Data List [W] Current from NX-ID No Unit configuration data Input current suppl y metho d 7 External Wei ght [g] Width [mm] data size [byte] Num ber poin ts /0 1/0 16 point s NX-ID /0 32 point s Summary specifications Number entry mappings Internal common For both NPN/P NP For both NPN/P NP Rated input voltage 24 VDC 24 VDC refres hing metho d ON/OFF respon se time Sync 20/400 μs max. 1-9

32 1 Data List DC Input Units (Fujitsu Connector, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Rated input voltage refreshing method The number input points provided by the Unit. Description This is the polarity that the Unit uses to connect to input devices. There are models with NPN and PNP connections. The rated input voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and input refreshing with input changed time are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Changed time: Input refreshing with input changed time The delay time for which the status change the input terminals reaches the internal circuit the Unit. The input filter time is not included. It is described according to the ON/OFF sequence. Data List [W] Current from NX-ID No Unit configuration data Input current suppl y metho d 4.1 External Wei ght [g] Width [mm] data size [byte] Num ber poin ts /0 1/0 32 point s Summary specifications Number entry mappings Internal common For both NPN/P NP Rated input voltage 24 VDC refres hing metho d ON/OFF respon se time Sync 20/400 μs max. 1-10

33 1 Data List AC Input Units (Screwless Clamping Terminal Block, 12 mm Width) Items in the Summary Specifications Item Number points Internal common Rated input voltage refreshing method ON/OFF response time The number input points provided by the Unit. Description This is the polarity that the Unit uses to connect to input devices. There are models with NPN and PNP connections. The rated input voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and input refreshing with input changed time are available. In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Changed time: Input refreshing with input changed time The delay time for which the status change the input terminals reaches the internal circuit the Unit. The input filter time is not included. It is described according to the ON/OFF sequence. 1-3 Digital Units Digital Input Units Data List [W] Current from Unit configuration data Input current 9 (200 VAC/50 Hz) 11 (200 VAC/60 Hz) NX-IA No metho d External Wei ght [g] Width [mm] data size [byte] /0 bits Num ber poin ts 1/0 4 point s Summary specifications Number entry mappings Internal common No polarity Rated input voltage 200 to 240 VAC refres hing metho d ON/OFF respon se time Free 10/40 ms max. 1-11

34 1 Data List Digital Output Units Transistor Output Units (Screwless Clamping Terminal Block, 12 mm Width) Items in the Summary Specifications Item Number points Internal common Maximum load current Rated voltage refreshing method Description The number output points provided by the Unit. This is the polarity that the Unit uses to connect to output devices. There are models with NPN and PNP connections. The maximum output load current the Unit. Specifications for each output point and for the Unit are described. The rated output voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and output refreshing with specified time stamp are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Specified time: Output refreshing with specified time stamp The delay time for which data in the internal circuit is reflected in the state output elements the Unit. It is described according to the ON/OFF sequence. 1-12

35 1 Data List Data List [W] Current from Unit configuration data powe r meth od Wei ght [g] Widt h [mm] data size [byte] Nu mbe r poin ts Summary specifications Number entry mappings Internal common Maximum load current NX-OD2154 NX-OD NX bus /18 1/1 2 point s NPN PNP 0.5 A/ point, 1 A/ Unit NX-OD /4 bits 0/1 4 point s NPN 0.5 A/ point, 2 A/ Unit Rated voltage refres hing meth od 24 VDC Specified time 12 to 24 VDC ON/OFF respon se time 300/ 300 ns max. Sync 0.1/0.8 ms max. NX-OD VDC 300/ 300 ns max. NX-OD PNP 0.5/1.0 ms max. NX-OD / 300 ns max. NX-OD external NX-OD NX bus 0/2 8 point s 2 A/ point, 8 A/ Unit NPN 0.5 A/ point, 4 A/ Unit 12 to 24 VDC 0.5/1.0 ms max. 0.1/0.8 ms max. NX-OD PNP 24 VDC 0.5/1.0 ms max. NX-OD point s NPN 12 to 24 VDC 0.1/0.8 ms max. NX-OD PNP 24 VDC 0.5/1.0 ms max. 1-3 Digital Units Digital Output Units 1-13

36 1 Data List Transistor Output Units (M3 Screw Terminal Block, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Maximum load current Rated voltage refreshing method Description The number output points provided by the Unit. This is the polarity that the Unit uses to connect to output devices. There are models with NPN and PNP connections. The maximum output load current the Unit. Specifications for each output point and for the Unit are described. The rated output voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and output refreshing with specified time stamp are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Specified time: Output refreshing with specified time stamp The delay time for which data in the internal circuit is reflected in the state output elements the Unit. It is described according to the ON/OFF sequence. Data List [W] Current from Unit configuration data metho d Weigh t [g] Widt h [mm] data size [byte] Number entry mappings Number point s NX-OD External /2 0/1 16 points Inter nal com mon Summary specifications Maximum load current NPN 0.5 A/ point, 5 A/ Unit Rated voltage 12 to 24 VDC NX-OD PNP 24 VDC refres hing metho d ON/O FF respo nse time Sync 0.1/0. 8 ms max. 0.5/1. 0 ms max. 1-14

37 1 Data List Transistor Output Units (MIL Connector, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Maximum load current Rated voltage refreshing method ON/OFF response time Description The number output points provided by the Unit. This is the polarity that the Unit uses to connect to output devices. There are models with NPN and PNP connections. The maximum output load current the Unit. Specifications for each output point and for the Unit are described. The rated output voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and output refreshing with specified time stamp are available. In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Specified time: Output refreshing with specified time stamp The delay time for which data in the internal circuit is reflected in the state output elements the Unit. It is described according to the ON/OFF sequence. 1-3 Digital Units Digital Output Units Data List [W] Current from Unit configuration data metho d Weigh t [g] Widt h [mm] data size [byte] Number entry mappings Number point s NX-OD External /2 0/1 16 points Inter nal com mon Summary specifications Maximum load current NPN 0.5 A/point, 2 A/Unit 12 to 24 VDC NX-OD PNP 24 VDC NX-OD /4 32 points Rated voltage NPN 0.5 A/point, 2 A/common, 4A/Unit NX-OD PNP 24 VDC 12 to 24 VDC refres hing metho d ON/O FF respo nse time Sync 0.1/0.8 ms max. 0.5/1. 0 ms max. 0.1/0.8 ms max. 0.5/1.0 ms max. 1-15

38 1 Data List Transistor Output Units (Fujitsu Connector, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Maximum load current Rated voltage refreshing method Description The number output points provided by the Unit. This is the polarity that the Unit uses to connect to output devices. There are models with NPN and PNP connections. The maximum output load current the Unit. Specifications for each output point and for the Unit are described. The rated output voltage the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing and output refreshing with specified time stamp are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Specified time: Output refreshing with specified time stamp The delay time for which data in the internal circuit is reflected in the state output elements the Unit. It is described according to the ON/OFF sequence. Data List [W] Current from Unit configuration data metho d Weigh t [g] Widt h [mm] data size [byte] Number entry mappings Number point s NX-OD External /4 0/1 32 points Inter nal com mon Summary specifications Maximum load current NPN 0.5 A/ point, 2 A/common, 4 A/Unit Rated voltage 12 to 24 VDC refres hing metho d ON/O FF respo nse time Sync 0.1/0.8 ms max. 1-16

39 1 Data List Relay Output Units (Screwless Clamping Terminal Block, 12 mm Width) Items in the Summary Specifications 1-3 Digital Units Item Number points Relay type Maximum switching capacity refreshing method ON/OFF response time Data List Description The number output points provided by the Unit. The type relay that is connected to the Unit. There are N.O. and N.O. + N.C. The maximum value switchable current the relay that is connected to the Unit. The refreshing methods that are used by the Unit. Free-Run refreshing and synchronous refreshing are available. In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing The delay time for which data in the internal circuit is reflected in the state output elements the Unit. It is described according to the ON/OFF sequence Digital Output Units [W] Current from Unit configuration data Wei ght [g] Widt h [mm] /2 bit data size [byte] Number entry mappings Nu mbe r poin ts NX-OC No powe r meth od External 0/1 2 point s, independent contacts Relay type NX-OC N.O. + N.C. N.O. Summary specifications Maximum switching capacity 250 VAC/2 A (cosφ = 1), 250 VAC/2 A (cosφ = 0.4), 24 VDC/2 A, 4 A/Unit refres hing metho d ON/OFF respon se time Free 15/15 ms max. 1-17

40 1 Data List Digital Mixed Units DC Input/Transistor Output Units (MIL Connector, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Maximum load current Rated voltage refreshing method Description The number output and input points provided by the Unit. The first value in this column is for output, and the latter is for input. This is the polarity that the Unit uses to connect to output and input devices. There are models with NPN and PNP connections. The first value in this column is for output, and the latter is for input. The maximum output load current the Unit. Specifications for each output point and for the Unit are described. The rated output voltage and rated input voltage the Unit. The first value in this column is for output, and the latter is for input. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing, output refreshing with specified time stamp and input refreshing with input changed time are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Specified time: Output refreshing with specified time stamp Changed time: Input refreshing with input changed time For outputs, the delay time for which data in the internal circuit is reflected in the state output elements the Unit. For inputs, the delay time for which the status change the input terminals reaches the internal circuit the Unit. The input filter time is not included. The first two values in this column are for output, and the latter two are for input. 1-18

41 1 Data List Data List NX Unit [W] Current from Unit configuration data Input curre nt pow er supp ly meth od NX-MD Exter nal Weig ht [g] Widt h [mm] data size [byte ] Num ber entry mapping s Number points /2 1/1 16 points, 16 points NPN, for both NPN/P NP NX-MD PNP, for both NPN/P NP Summary specifications Internal common Maximum load current 0.5 A/ point, 2 A/ Unit Rated voltage 12 to 24 VDC, 24 VDC 24 VDC, 24 VDC refre shin g meth od ON/OF F respo nse time Sync 0.1/0.8 ms max., 20/400 μs max. 0.5/1.0 ms max., 20/400 μs max. 1-3 Digital Units Digital Mixed Units 1-19

42 1 Data List DC Input/Transistor Output Units (Fujitsu Connector, 30 mm Width) Items in the Summary Specifications Item Number points Internal common Maximum load current Rated voltage refreshing method Description The number output and input points provided by the Unit. The first value in this column is for output, and the latter is for input. This is the polarity that the Unit uses to connect to output and input devices. There are models with NPN and PNP connections. The first value in this column is for output, and the latter is for input. The maximum output load current the Unit. Specifications for each output point and for the Unit are described. The rated output voltage and rated input voltage the Unit. The first value in this column is for output, and the latter is for input. The refreshing methods that are used by the Unit. Free-Run refreshing, synchronous refreshing, output refreshing with specified time stamp and input refreshing with input changed time are available. ON/OFF response time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing Specified time: Output refreshing with specified time stamp Changed time: Input refreshing with input changed time For outputs, the delay time for which data in the internal circuit is reflected in the state output elements the Unit. For inputs, the delay time for which the status change the input terminals reaches the internal circuit the Unit. The input filter time is not included. The first two values in this column are for output, and the latter two are for input. Data List NX Unit [W] Current from Unit configuration data Input curre nt pow er supp ly meth od NX-MD Exter nal Weig ht [g] Widt h [mm] data size [byte ] Number entry mappings Number points /2 1/1 16 points, 16 points NPN, for both NPN/P NP Summary specifications Internal common Maximum load current 0.5 A/ point, 2 A/ Unit Rated voltage 12 to 24 VDC, 24 VDC refre shin g meth od ON/OF F respo nse time Sync 0.1/0.8 ms max., 20/400 μs max. 1-20

43 1 Data List 1-4 Analog Units This section describes the data for Analog Units. 1-4 Analog Units Analog Input Units 1 Analog Input Units (Screwless Clamping Terminal Block, 12 mm Width) Items in the Summary Specifications Item Number points Input range Resolution Input method Description The number analog input points provided by the Unit. The input range the Unit. The resolution converted values the Unit. The analog signal input method provided by the Unit. Single-ended input and differential input are available Analog Input Units refreshing method In the following table, the following abbreviations are used. Single: Single-ended input Diff: Differential input The refreshing methods that are used by the Unit. Free-Run refreshing and synchronous refreshing are available. Conversion time In the following table, the following abbreviations are used. Free: Free-Run refreshing Sync: Switching synchronous refreshing and Free-Run refreshing The time required per input to convert analog input signals the Unit to the converted values. 1-21

Machine Automation Controller. NX-series NX- Data Reference Manual W525-E1-04

Machine Automation Controller. NX-series NX- Data Reference Manual W525-E1-04 Machine Automation Controller NX-series Data Reference Manual NX- W525-E1-04 OMRON, 2013 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

Data Reference Manual

Data Reference Manual Machine Automation Controller NX-series Data Reference Manual NX- W525-E1-17 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any

More information

Machine Automation Controller. NX-series NX- Data Reference Manual W525-E1-03

Machine Automation Controller. NX-series NX- Data Reference Manual W525-E1-03 Machine Automation Controller NX-series Data Reference Manual NX- W525-E1-03 OMRON, 2013 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

Data Reference Manual

Data Reference Manual Machine Automation Controller NX-series Data Reference Manual NX-@@@@@@ W525-E1-01 OMRON, 2013 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

IO-Link System. User s Manual W570-E1-03

IO-Link System. User s Manual W570-E1-03 IO-Link System User s Manual W570-E1-03 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical,

More information

IO-Link System. User s Manual W570-E1-04

IO-Link System. User s Manual W570-E1-04 IO-Link System User s Manual W570-E1-04 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted, in any form, or by any means, mechanical,

More information

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001

Options. 24-VDC service power supply. RUN output. No Yes No 24 VDC 70 W NX-PD7001 NX-Series Power Supply Unit CSM_NX-PA_PD_DS_E_2_2 Powerful power supply unit to supply stable power to the NX-series controller. Stable power supply is available from the NX-series CPU Unit to each I/O

More information

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature

NJ NJ-series NJ501 SECS/GEM CPU Unit. Allows SECS/GEM communications in a short time with a simple configuration. Feature NJ-series NJ501 SECS/GEM CPU Unit NJ501-1340 CSM_NJ501-1340_DS_E_3_1 Allows SECS/GEM communications in a short time with a simple configuration. The NJ501 SECS/GEM CPU Unit is a NJ-series machine automation

More information

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring.

CQM1 I/O Terminal Block Conversion Adapter. Easy and secure replacement by reusing the I/O terminal block wiring. CQM1 I/O CSM_CJ1W-AT4 DS_E_1_1 Easy and secure replacement by reusing the I/O terminal block wiring You can replace CQM1(H) Series with CJ Series, efficiently using your assets. Time for wiring works and

More information

Practices Guide OMRON Standard IAG Library

Practices Guide OMRON Standard IAG Library Programmable Terminal NA-series Practices Guide OMRON Standard IAG Library NA5-15[]101[] NA5-12[]101[] NA5-9[]001[] NA5-7[]001[] V415-E1-04 Introduction This guide provides reference information for the

More information

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Name No. of I/O points Model Safety inputs: 12, test outputs: 4 Safety I/O s DST1 Series CSM_DST1 Series_DS_E_7_3 Distributed Safety s That Reduce Wiring. Lineup includes four models to accommodate various I/O types and number of I/O points. Monitor the safety system

More information

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5

CX-Designer Ver.3 CSM_CX-Designer_DS_E_5_5 FA Integrated Tool Package CX-One Ver.3 CSM DS_E_5_5 Intuitive operability will increase programming efficiency from screen data creation to debugging for NS series. is the programming software for debugging

More information

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE

Name Specifications Model Standards RS-422A Converter. Converts RS-233C to RS-422A/RS-485. CJ1W-CIF11 UC1, N, L, CE SYSMAC Option CSM DS_E_2_1 The RS-232C port of the SYSMAC series can be changed into RS-422A/485 port. The connects directly to a CS/CJ-series RS-232C port and converts RS-232C to RS-422A/485. Features

More information

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications.

NE1A-SCPU Series. Safety Network Controller. Achieve Safety Control through Programming. Ordering Information. Specifications. Safety Network Controller NEA-SCPU Series CSM_NEA-SCPU_Series_DS_E Achieve Safety Control through Programming. Compact Safety Controller. The NEA-SCPU-V provides built-in safety inputs and 8 built-in safety

More information

Features various encoder interfaces and controls multiple analog servo drives at high speeds

Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W Axial Interface Unit CK3W-AX Features various encoder interfaces and controls multiple analog servo drives at high speeds CK3W-AX Features One CK3W-AX Unit controls up to four axes Analog input type

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units.

The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation. Fiber Units. Sensor Communications Unit CSM DS_E_1_1 The Next-generation Sensor Networking Units That Revolutionize the Workplace from Introduction and Startup though Operation Low initial cost achieved by distributed

More information

CX-One Ver.4 CSM_CX-One_DS_E_10_2

CX-One Ver.4 CSM_CX-One_DS_E_10_2 FA Integrated Tool Package CX-One CSM_CX-One_DS_E_10_2 Greater Integration with the CX-One The CX-One is a comprehensive software package that integrates PLC Programming Software with Support Software

More information

Safety Network Controller NX-series Communication Control Unit User's Manual. Built-in Function NX-CSG. Communication Control Unit

Safety Network Controller NX-series Communication Control Unit User's Manual. Built-in Function NX-CSG. Communication Control Unit Safety Network Controller NX-series Communication Control Unit User's Manual Built-in Function NX-CSG Communication Control Unit NOTE (1) All rights reserved. No part of this publication may be reproduced,

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

Machine Automation Controller NJ/NX-series Database Connection CPU Units. User s Manual NX NX NJ NJ CPU Unit W527I-E3-10

Machine Automation Controller NJ/NX-series Database Connection CPU Units. User s Manual NX NX NJ NJ CPU Unit W527I-E3-10 Machine Automation Controller NJ/NX-series Database Connection CPU Units User s Manual NX701-20 NX102-20 NJ501-20 NJ101-20 CPU Unit W527I-E3-10 NOTE All rights reserved. No part of this publication may

More information

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals.

Maintenance information. DRT2-series. Remote I/O Terminals Relay Output Terminals. DRT2-series Smart Slave Analog I/O Terminals. CS-series Net Unit CSM DS_E_5_3 A Net Unit for the CS Series That Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words) per master, and ensures

More information

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort,

CS1W-B7A. CS-series B7A Interface Unit. It transmits 16 points of I/O signals per word with a pair of cables. Easy and minimized wiring effort, CPU42 RUN ERR/ALM INH PRPHL/COMN OPEN MCPWR BUSY OPEN PERIPHERAL PORT (RS-232C) CS-series B7A Interface Unit CSM DS_E_3_2 It transmits 16 points of I/O signals per word with a pair of cables. Easy and

More information

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel I/O Relay CSM DS_E_4_4 Slim-styled I/O Relay Saves Space in Panel SPST-NO, SPST-NC, and SPDT contact forms available for output (SPST-NO only for input). Ultra-slim housing measuring 29 (W) x 0 (D) x 2

More information

CX-One Ver.4 CSM_CX-One_DS_E_8_2

CX-One Ver.4 CSM_CX-One_DS_E_8_2 FA Integrated Tool Package CX-One CSM_CX-One_DS_E_8_2 Greater Integration with the CX-One The CX-One is a comprehensive software package that integrates PLC Programming Software with Support Software for

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

Connecting Sockets, Mounting Brackets, DIN Rails

Connecting Sockets, Mounting Brackets, DIN Rails Connecting Sockets, Mounting Brackets, DIN Rails CSM_ConnectionSocket_DS_E_3_1 Durable, Easy-to-handle Connecting Sockets and Mounting Brackets Highly reliable Track-mounted and Back-connecting Sockets

More information

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure

M22. Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Indicator (Cylindrical 22/25-dia.) List of Models. Model Number Structure Indicator (Cylindrical 22/25-dia.) CSM DS_E_3_4 Round Indicator Series with 22 dia. and 25 dia. (when using a ring) Same type as the A22-series Pushbutton Switches. Use 25-dia. ring to install in 25-dia.

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

NX-TS. NX-series Temperature Input Unit

NX-TS. NX-series Temperature Input Unit NX-series Temperature Input Unit NX-TS CSM_NX-TS_DS_E_1_1 Temperature Input Units for Low-speed and High-speed*, High-precision* Temperature Control in Combination with NJ Series NX-series Temperature

More information

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models Solid State Relays CSM DS_E_5_3 100-μA-max. Leakage Current, No Bleeder Resistor Required Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket (according to actual OMRON measurements).

More information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information

E3Z-G. Photoelectric Sensor with Grooved Design and Easy Settings. Grooved-type Photoelectric Sensor with Built-in Amplifier. Ordering Information Grooved-type with Built-in Amplifier EZ-G CSM_EZ-G_DS_E_9_ with Grooved Design and Easy Settings Groove-type with groove width of 5 mm. Models are available with one or two light axes. Models are available

More information

CSM_NX-HAD DS_E_DITA_2_1

CSM_NX-HAD DS_E_DITA_2_1 NX-series High-speed Analog Input Unit NX-HAD@@@ CSM_NX-HAD DS_E_DITA_2_1 Simultaneous sampling of 4 channels with sampling times down to 5 µs NX-series High-speed Analog Input Unit Multi-range inputs:

More information

IPC Machine Controller Industrial Panel PC / Industrial Box PC

IPC Machine Controller Industrial Panel PC / Industrial Box PC Industrial PC Platform NY-series IPC Machine Controller Industrial Panel PC / Industrial Box PC Setup User s Manual NY532-1500 NY532-1400 NY532-1300 NY512-1500 NY512-1400 NY512-1300 Industrial Panel PC

More information

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors

Type Terminal Block Connector No. of poles Appearance Model 40 XW2B-40G4 50 XW2B-50G4. 40 XW2B-40G5 Flat Cable Connectors Standard-type Connector- Conversion Units XWB CSM_XWB_DS_E Simplifies Connector and terminal block replacement, and requires less in-panel wiring. Mount to DIN Track or via screws. MIL Flat Cable Connectors

More information

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model

Sensing method Appearance Connection method Sensing distance Model. Pre-wired (2 m) Power supply Application Appearance Function Model Small Spot/Mark (Separate Amplifier) EC-VS/VM CSM_EC-VS/VM_DS_E_6_ Extremely thin beam ideal for detection of minute objects and marks Ideal for detection of small objects and slight color differences

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

IPC Machine Controller Industrial Panel PC / Industrial Box PC

IPC Machine Controller Industrial Panel PC / Industrial Box PC Industrial PC Platform NY-series IPC Machine Controller Industrial Panel PC / Industrial Box PC Motion Control User s Manual NY532-1500 NY532-1400 NY532-1300 NY532-5400 NY512-1500 NY512-1400 NY512-1300

More information

CSM_PYF S/P2RF- -S_DS_E_2_5

CSM_PYF S/P2RF- -S_DS_E_2_5 Screwless Clamp Terminal Sockets PYF@@S/P2RF-@@-S CSM_PYF S/P2RF- -S_DS_E_2_5 New Screwless Terminal Sockets Added for MY and G2R Relays. Simplified wiring without tightening screws. Two wires can be independently

More information

CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5

CJ1W-DRM21 CSM_CJ1W-DRM21_DS_E_8_5 CJ-series Net Unit CSM DS_E_8_5 Smallest in the Industry! A Net Unit for the CJ Series that Boasts Industry-leading Performance and Functions Features Allows control of up to 32,000 points (2,000 words)

More information

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G@-VD CSM_GH_GHD_DS_E_6_ New Models with International Standards Added to GH Series (-VD in model number). Same Profile as LY and LY Bi-power Relays Certified by UL, CSA, and VDE (models

More information

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs I/O Terminal Socket PTF-IS/OS/OS CSM_PTF-IS_OS_OS_DS_E I/O Terminal Sockets to Flexibly Build Systems Mount either GT I/O Relays or GTA SSRs. Compact size for both Input and Output I/O Terminal Sockets:

More information

NX1P2 CPU Unit. Built-in I/O and Option Board User s Manual. Machine Automation Controller NX-series

NX1P2 CPU Unit. Built-in I/O and Option Board User s Manual. Machine Automation Controller NX-series Machine Automation Controller NX-series NX1P2 CPU Unit Built-in I/O and Option Board User s Manual NX1P2-11 NX1P2-11 1 NX1P2-10 NX1P2-10 1 NX1P2-90 NX1P2-90 1 CPU Unit W579-E1-01 NOTE All rights reserved.

More information

Sysmac Library. User s Manual for Temperature Control Library SYSMAC-XR007 W551-E1-03

Sysmac Library. User s Manual for Temperature Control Library SYSMAC-XR007 W551-E1-03 Sysmac Library User s Manual for Temperature Control Library SYSMAC-XR007 W551-E1-03 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5

CX-Integrator Ver.2 CSM_CX-Integrator_Ver2_DS_E_6_5 FA Integrated Tool Package CX-One CSM_CX-Integrator_Ver2_DS_E_6_5 Easily Monitor Network Connection Status, Set Parameters, Diagnose Networks, and Do Much More from Your Computer Application software to

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ

NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ NJ-series Machine Automation Controller SECS/GEM CPU Unit NJ501-1340 HSMS communications HOST NJ-series Machine Automation Controller with built-in semiconductor industry standard SECS/GEM communications

More information

Model A7BS

Model A7BS Thumbwheel Switch ABS/ABL CSM_ABS/ABL_DS_E Wide Range of Locking-type s Available Character height of.8 or. mm makes for easy-toview display. Installation is easy with snap-in mounting. The series includes

More information

Database Connection CPU Units

Database Connection CPU Units Machine Automation Controller NJ/NX-series Database Connection CPU Units User s Manual NX701-1720 NX701-1620 NJ501-1520 NJ501-1420 NJ501-1320 NJ501-4320 NJ101-1020 NJ101-9020 CPU Unit W527-E1-08 NOTE All

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News

Probe Pin XP3A. Electroplated Probe Pin for High Reliability. Feature. List. New Product News New Product News Probe Pin Electroplated Probe Pin for High Reliability The Probe Pin that is made of only one part. The flat structure helps you reduce the pin pitch in comparison with standard probe

More information

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend Solid State Relays G3@-VD CSM_G3F_G3FD_DS_E_5_3 International Standards for G3F Series, Same Profile as MY Power Relays Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket

More information

Indicator (Square) Ultra Bright LED Type

Indicator (Square) Ultra Bright LED Type New Products Indicator (Square) Ultra Bright LED Type M2S Indicator Series with Square 40-mm Body. New models added with Ultra LEDs. New models with ultra bright LEDs added to singlescreen models. Previous

More information

CPU Unit Built-in EtherCAT Port

CPU Unit Built-in EtherCAT Port Machine Automation Controller NJ/NX-series CPU Unit Built-in EtherCAT Port User s Manual NX701-17 NX701-16 NX1P2-11 NX1P2-10 NX1P2-90 NJ501-5 NJ501-4 NJ501-3 NJ301-12 NJ301-11 NJ101-10 NJ101-90 CPU Unit

More information

NX-DA CSM_NX-DA_DS_E_3_1

NX-DA CSM_NX-DA_DS_E_3_1 NX-series Analog Output Unit NX-DA CSM_NX-DA_DS_E_3_1 Analog Outputs to meet all machine control needs; from general-purpose outputs to highspeed synchronous, highresolution control outputs Analog Output

More information

Indicator (Square) Ultra Bright LED Type

Indicator (Square) Ultra Bright LED Type New Products Indicator (Square) Ultra Bright LED Type M2P Large Square-bodied Indicators. New models added with Ultra LEDs. New models with ultra bright LEDs added to single- models. Previous models not

More information

G code Instructions Reference Manual

G code Instructions Reference Manual Machine Automation Controller Industrial PC Platform NJ/NY-series G code Instructions Reference Manual NJ501-5300 NY532-5400 O031-E1-01 NOTE All rights reserved. No part of this publication may be reproduced,

More information

Electroformed Probe Pins XP3A

Electroformed Probe Pins XP3A New Product Electroformed Probe Pins Electroplated Probe Pins for High Reliability The Probe Pin that is made of only one part. The flat structure helps you reduce the pin pitch in comparison with standard

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information

E2EC. Subminiature Sensors with Long-distance Detection. Cable Amplifier Proximity Sensor. Ordering Information Cable Amplifier Proximity Sensor EEC CSM_EEC_DS_E_9_ Subminiature Sensors with Long-distance Detection Shielded Sensor Heads from -mm to M diameters that can be embedded in metal. Robotics cables provided

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21 Solid-state timer CSM DS_E_3_2 Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating

More information

Number of input channels

Number of input channels Safety Relay Unit (Sensor Connector Type) CSM DS_E_3_1 Less Wiring Required with Safety Light Curtain Sensor connector allows direct connection to OMRON 3SJ Safety Light Curtains with PNP outputs. Reduces

More information

Servo System 1S-series. Startup Guide. R88M-1L[]/-1M[] (AC Servomotors) R88D-1SN[]-ECT (AC Servo Drives) I823-E1-01

Servo System 1S-series. Startup Guide. R88M-1L[]/-1M[] (AC Servomotors) R88D-1SN[]-ECT (AC Servo Drives) I823-E1-01 Servo System 1S-series Startup Guide R88M-1L[]/-1M[] (AC Servomotors) R88D-1SN[]-ECT (AC Servo Drives) I823-E1-01 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

Reuse Terminal Block Wiring When Replacing PLCs. Terminal Block Conversion Adapters. Overview. Features. System Configuration

Reuse Terminal Block Wiring When Replacing PLCs. Terminal Block Conversion Adapters. Overview. Features. System Configuration s CSM_X7G-CS - DS_E_1_1 Reuse Terminal Block iring hen Replacing PLCs 32-point Terminal Block Conversion s for Fujitsu Connectors X7G-CS01-1/CS01-2/CS01-3 16-point Terminal Block Conversion for One-slot

More information

Model NPN output PNP output Standard. configuration

Model NPN output PNP output Standard. configuration Slot-type Photomicrosensor (Non-modulated) *1 EE-SX/6 CSM_EE-SX/6_DS_E_1_ Global Standard Slot-type photomicrosensors with 0- to 100-mA direct switching capacity. Series includes that enable switching

More information

CSM_NX-PG0 DS_E_4_4

CSM_NX-PG0 DS_E_4_4 NX-series Pulse Output Unit NX-PG0@@@ CSM_NX-PG0 DS_E_4_4 Positioning with Pulse Input Type Motor Drivers Such As Stepper Motor Drive The MC Function Modules of the NJ-series Machine Automation Controller

More information

E4C-UDA CSM_E4C-UDA_DS_E_12_2

E4C-UDA CSM_E4C-UDA_DS_E_12_2 Digital Amplifier Ultrasonic Sensor E4C-UDA CSM_E4C-UDA_DS_E_12_2 Compact, Cylindrical Reflective Ultrasonic Sensor with Easy Setting Stable operation for a variety of objects regardless of color, transparency,

More information

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor

ZN-CTX/-CTM. Portable Power Monitor. Easy and Quick Checking Power at the Worksite. Ordering Information. Portable Power Monitor Portable Power Monitor ZN-CTX/-CTM CSM_ZN-CTX_-CTM_DS_E 2 Easy and Quick Checking Power at the Worksite Display and record power consumption without stopping the power supply. Battery driven, mounted with

More information

Machine Automation Controller NJ-series. Startup Guide. for CPU Unit W513-E1-02

Machine Automation Controller NJ-series. Startup Guide. for CPU Unit W513-E1-02 Machine Automation Controller NJ-series Startup Guide for CPU Unit W513-E1-02 OMRON, 2011 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction.

Aluminum Excellent Performance, with Aluminum Chip Immunity! The indicator is visible from any direction. All Metals and Long- Types CSM DS_E and Both Detectable from Long Distances times the aluminum detection of previous models Twice the max. Equipped with a function to prevent the detection of aluminum

More information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M Chip-immune Inductive EEZ CSM_EEZ_DS_E_6_ Chip-immune Inductive Correct operation even with aluminum or iron chips sticking to the. Only the sensing object is detected. Pre-wired Smartclick Connector s

More information

Dimension A. Dimension B

Dimension A. Dimension B Slim Connector-Terminal lock Conversion Units CSM DS_E_2_3 New Slim Connector-Terminal lock Conversion Units. Mounting area reduced by 35% (in comparison with 40-pole XW2 Units) to contribute to downsizing

More information

for Simulink & Sysmac Studio

for Simulink & Sysmac Studio NJ/NX/NY-series Controller Startup Guide for Simulink & Sysmac Studio SYSMAC-SE20 NX701- NX1P2- NJ501- NJ301- NJ101- NY532- NY512- R88D-KN -ECT R88D-1SN -ECT GX-AD0471/DA0271 NX-AD NX-DA NA5- W NA5- W

More information

CPU Unit Motion Control

CPU Unit Motion Control Machine Automation Controller NJ-series CPU Unit Motion Control User s Manual NJ501-1300 NJ501-1400 NJ501-1500 CPU Unit W507-E1-01 OMRON, 2011 All rights reserved. No part of this publication may be reproduced,

More information

CJ Series EtherNet/IP TM Connection Guide. OMRON Corporation NX-series EtherNet/IP Coupler Unit P656-E1-01

CJ Series EtherNet/IP TM Connection Guide. OMRON Corporation NX-series EtherNet/IP Coupler Unit P656-E1-01 CJ Series EtherNet/IP TM Connection Guide OMRON Corporation NX-series EtherNet/IP Coupler Unit P656-E1-01 About Intellectual Property Rights and Trademarks Microsoft product screen shots reprinted with

More information

Sysmac Library. User s Manual for Weighing Control Library SYSMAC-XR010 W569-E1-02

Sysmac Library. User s Manual for Weighing Control Library SYSMAC-XR010 W569-E1-02 Sysmac Library User s Manual for Weighing Control Library SYSMAC-XR010 W569-E1-02 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

Model Number Structure

Model Number Structure Digital Panel Meter CSM DS_E_3_1 Easy-to-use, w-cost Digital Panel Meter that Accepts DC Input Compact DIN-size (96 x 48 (W x H)) body. Mounting thickness of only 3.5 mm required. Highly visible display

More information

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M

E2EZ-X2D1-N 2M E2EZ-X2D2-N 2M Chip-immune Inductive EEZ CSM_EEZ_DS_E Chip-immune Inductive Correct operation even with aluminum or iron chips sticking to the. Only the sensing object is detected. Pre-wired Smartclick Connector s also

More information

Analog I/O Units. User s Manual for Analog Input Units and Analog Output Units. Machine Automation Controller NX-series NX-AD NX-DA.

Analog I/O Units. User s Manual for Analog Input Units and Analog Output Units. Machine Automation Controller NX-series NX-AD NX-DA. Machine Automation Controller NX-series Analog I/O Units User s Manual for Analog Input Units and Analog Output Units NX-AD NX-DA Analog I/O Units W522-E1-10 NOTE All rights reserved. No part of this publication

More information

Startup Guide for Multi-axis Setup and Tuning

Startup Guide for Multi-axis Setup and Tuning AC Servo System 1S-series Startup Guide for Multi-axis Setup and Tuning R88M-1L[]/-1M[] (AC Servomotors) R88D-1SN[]-ECT (AC Servo Drives) SYSMAC-SE20[][] (Automation Software) I827-E1-01 NOTE All rights

More information

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs.

CJ1W-INT01. CJ-series Interrupt Input Units. High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 32 Interrupt Inputs. CJ-series Interrupt Input Units CSM DS_E 1 High-speed Starting of I/O Interrupt Tasks. Use Up to Two Units for a Total of Up to 3 Interrupt Inputs. Receive inputs to start I/O interrupt tasks. When the

More information

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor

NYM CSM_NYM_DS_E_2_2. Very stylish, very industrial. Features. Industrial PC Platform NY-series Industrial Monitor Industrial PC Platform NY-series Industrial Monitor CSM DS_E_2_2 Very stylish, very industrial Our new industrial-quality touchscreen monitors are good-looking but more importantly they also enable the

More information

Knob-type Selector Switches

Knob-type Selector Switches New Product Knob-type Selector Switches ANS/ANW Selector Switches with -mm Diameters. Universal Design That Emphasizes Color Coding, Workability, and Safety Easy to Use You can connect up to three Switch

More information

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5

CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5 FA Integrated Tool Package CX-One CX-Simulator Ver.1 CSM_CX-Simulator_Ver1_DS_E_7_5 Increase Development and Debugging Efficiency with Various Debugging Tools, Including Functions That Are Not Possible

More information

User s Manual for Communications Settings

User s Manual for Communications Settings Displacement Sensor series Confocal Fiber Type Displacement Sensor ZW-7000@ ZW-5000@ Z363-E1-05 Introduction Thank you for purchasing the Series. This manual provides information regarding functions, performance

More information

M16-J M16-A M16-T

M16-J M16-A M16-T Indicator (Cylindrical 16-dia.) CSM DS_E_7_2 Cylindrical 16-dia. Indicator Same basic design as the A16 Pushbutton Switch. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety

More information

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information

E6J-C. Ultracompact Rotary Encoder with External Diameter of 20 mm. Ultracompact 20-mm-dia. Incremental Rotary Encoder. Ordering Information Ultracompact 20-mm-dia. Incremental Rotary Encoder CSM DS_E_4_1 Ultracompact Rotary Encoder with External Diameter of 20 mm Incremental model External diameter of 20 mm. Resolution of up to 1,000 ppr.

More information

NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_4

NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_4 NX-series Safety Control Units NX-SL/SI/SO CSM_NX-SL_SI_SO_E_4_4 Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration. EN ISO13849-1 (PLe/Safety Category4), IEC 61508

More information

Sysmac Library. User s Manual for EtherCAT 1S Series Library SYSMAC-XR011 W571-E1-02

Sysmac Library. User s Manual for EtherCAT 1S Series Library SYSMAC-XR011 W571-E1-02 Sysmac Library User s Manual for EtherCAT 1S Series Library SYSMAC-XR011 W571-E1-02 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time

Type High-sensitivity. Medium-sensitivity models models Sensed current 30 ma (fixed) 100 ma/200 ma 200 ma/500 ma 500 ma/1,000 ma Operating time Ground Fault Relay CSM DS_E_9_3 Economical, Compact, High-performance, DIN 8 8-mm Ground Fault Relay for Low Voltages Performs continuous monitoring and detection of ground faults in low-voltage circuits

More information

NX-SL/SI/SO. NX-series Safety Control Units. Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration.

NX-SL/SI/SO. NX-series Safety Control Units. Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration. NX-series Safety Control Units NX-SL/SI/SO CSM_NX-SL_SI_SO_E_2_2 Integration of Safety into Machine Automation Enables Simple, Flexible System Configuration. EN ISO13849-1 (PLe/Safety Category4), IEC 61508

More information

Photoelectric Sensor

Photoelectric Sensor Photoelectric Sensor Small General-purpose Photoelectric Sensor with Built-in Power Supply Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only 50 x 50 x

More information

Machine Automation Controller NX1P

Machine Automation Controller NX1P Machine Automation NX1P 2 Machine Automation NX1P Advanced motion control and networks Open industrial Ethernet network Interface with HMI Peer-to-Peer controller communication Interface with Sysmac Studio

More information

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate

G9H. Ordering Information. Hybrid Power Relay. List of Model. Accessories (Order Separately) Connecting Socket Mounting Plate Hybrid Power elay CSM DS_E_6_ Hybridization of a Magnetic elay and an SS Achieves 0-A Switching for 0 Million Operations. UL/CSA certified (-US models). Using a triac to open and close the circuit reduces

More information

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4

CJ1W-CRM21 CSM_CJ1W-CRM21_DS_E_11_4 CJ-series CompoNet Master s CSM DS_E_11_4 NJ/CJ-series CompoNet Master s Increase the Range of Applicability of Sensors and Actuators. The NJ/CJ-series CompoNet Master manages the CompoNet network, controls

More information

Machine Automation Controller NX-series. Load Cell Input Unit. User s Manual NX-RS. Load Cell Input Unit W565-E1-04

Machine Automation Controller NX-series. Load Cell Input Unit. User s Manual NX-RS. Load Cell Input Unit W565-E1-04 Machine Automation Controller NX-series Load Cell Input Unit User s Manual NX-RS Load Cell Input Unit W565-E1-04 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval

More information

Sysmac Library. User s Manual for MC Command Table Library SYSMAC-XR002 W545-E1-04

Sysmac Library. User s Manual for MC Command Table Library SYSMAC-XR002 W545-E1-04 Sysmac Library User s Manual for MC Command Table Library SYSMAC-XR002 W545-E1-04 NOTE All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted,

More information

System Units. User s Manual. Machine Automation Controller NX-series NX-PD1 NX-PF0 NX-PC0 NX-TBX01

System Units. User s Manual. Machine Automation Controller NX-series NX-PD1 NX-PF0 NX-PC0 NX-TBX01 Machine Automation Controller NX-series System Units User s Manual NX-PD1 NX-PF0 NX-PC0 NX-TBX01 Additional NX Unit Power Supply Units Additional I/O Power Supply Units I/O Power Supply Connection Units

More information

Machine Automation Controller NJ Series

Machine Automation Controller NJ Series Machine Automation Controller NJ Series NJ501-4 Parallel, Cartesian and serial robot control functionality Increase machine control speed and precision Reduce machine development time Minimize machine

More information