D.C.M Dynamic Contact Measurement User Manual page 1(22) INDEX GENERAL APPLICATION AREA OVERVIEW SAFETY...

Size: px
Start display at page:

Download "D.C.M Dynamic Contact Measurement User Manual page 1(22) INDEX GENERAL APPLICATION AREA OVERVIEW SAFETY..."

Transcription

1 Rev 4

2 D.C.M Dynamic Contact Measurement User Manual page 1(22) INDEX INDEX GENERAL APPLICATION AREA OVERVIEW SAFETY GENERAL SAFETY INSTRUCTIONS CONNECTIONS CONNECTION TO PC Connecting with RS232 serial port Connecting with Bluetooth Create a Bluetooth connection Troubleshoot Bluetooth connection Remove the Bluetooth connection Installing Bluetooth adapter on a laptop that already has Bluetooth Installing Bluetooth adapter on computer with Windows Connecting with Ethernet (Requires BTS11 V1.6 or later) CONNECTION TO BREAKER POLES Connection for single phase and one contact element/phase Connection for single phase and two contact elements in series/phase Connection for 3-phases with two contact element in series/phase Connection for Rogowski coil on single phase and one contact element/phase Connection for Rogowski coil on single phase and two contact elements in series/phase OPERATION PREPARATION OPEN TEST WINDOW STATIC RESISTANCE MEASUREMENT DYNAMIC RESISTANCE MEASUREMENT TROUBLE SHOOTING NOT RECOGNIZE DCM UNITS NO TRIG NO MEASUREMENT MAINTENANCE BEFORE USE OR ACCORDING TO COMPANY POLICY CHECK EVERY 12 MONTHS OR ACCORDING TO COMPANY POLICY CHECK AND ADJUSTMENT CALIBRATION APPROVAL SERVICE WINDOW DCM CALIBRATION WINDOW CALIBRATION WIZARD - VOLTAGE INPUTS Voltage calibration- Step Voltage calibration- Step Voltage calibration- Step Voltage calibration- Step CALIBRATION WIZARD CURRENT OUTPUTS (RESISTANCE) Current calibration - Step Current calibration - Step Current calibration - Step TRANSPORTATION/SCRAPPING/RECYCLING SPECIFICATIONS DCM CU TECHNICAL SPECIFICATION DCM 2 TECHNICAL SPECIFICATION DCM KIT (ITEM NUMBER S160) INCLUDES DECLARATION OF CONFORMITY REVISIONS... 22

3 D.C.M Dynamic Contact Measurement User Manual page 2(22) 1 GENERAL 1.1 APPLICATION AREA The DCM units are used to perform dynamic contact measurements for High Voltage Circuit Breakers in sub stations with both side grounded. Static resistance measurement can also be performed for breakers with two contact element in series, both side grounded and the middle point not grounded. To be able to perform Static resistance measurement for breakers with one breaking element, only one side can be grounded. 1.2 OVERVIEW The test equipment for Dynamic contact measurement consists of one DCM-CU unit and from one up to three DCM-2 units. That means up to 6 contact elements can be tested at the same time. DCM-CU unit handles the communication between the PC, external switch analyser and DCM-2 unit(s). It also charge two capacitors (super cap) in each DCM-2 unit that is used to give a high measurement current during operation. DCM-2 unit(s) handles the output of the current and sample the current values and voltage drop values during the operation. After the operation has been done the current and voltage drop curves are downloaded to the PC-software for further evaluation. 2. SAFETY Important! 2.1 GENERAL This instrument shall only be used by authorized and educated personnel. It s the operators responsible to read and follow all operating and safety instructions for connecting and using this instrument. Always keep the below safety instructions in mind when using the instrument. 2.2 SAFETY INSTRUCTIONS Local safety regulations. Always follow local safety regulations for work on high-voltage circuit breakers. Ground connection The DCM units can only be used in electrical system with single grounds. If there is a High voltage ground and Low voltage ground make sure that there is no potential voltages difference between these grounds. If that s not the case, consult local safety regulations. Always connect the separate ground terminal on DCM-2 to protective ground before any other connections. Check that the separate protective ground wire is in good condition before connection. Make sure that the power socket for mains is a grounded outlet and that the power cable is in good condition before connecting the main power to the control unit DCM-CU. Connections to the instrument. All cables to the DCM units shall first be connected to the DCM-units (DCM-CU and DCM-2) before any connections to the test object. Only use original cables for connection and make sure that the cables are in good conditions. Before any connections to the high voltage circuit breaker. Make sure that the breaker is in Close position and disconnected from the line at both sides. Make sure that breaker is grounded on both sides. Make sure that any remote control device is disconnected from the control circuits of the breaker. Make first connection to the breaker poles before any connections to the breaker mechanism. Connections in general Take care when working near bare connectors and bus bars. Contact with a conductor may cause an electrical shock. Take special care at wet conditions. Surrounding personal Make sure that surrounding personal can t touch the breaker during a test

4 D.C.M Dynamic Contact Measurement User Manual page 3(22) 3. CONNECTIONS Important! Read safety instruction chapter 2. SAFETY before any connections 3.1 CONNECTION TO PC DCM 2 UNIT 1 BREAKER POL A DCM 2 UNIT 2 BREAKER POL B PC DCM CU DCM 2 UNIT 3 BREAKER POL C BREAKER CLOSE COIL SWITCH ANALYSER BREAKER TRIP COIL BREAKER MOTOR Take the supplied Serial connection cable DB9 of DCM CU and connect the DB9 Male connector to RS232 port of the Switch Analyser and connect the DB9 connector to RS232 TO SWITCH ANALYSER port of DCM CU. Connection between PC and DCM CU can be done in one of three ways. See chapter Connecting with RS232 serial port See chapter Connecting with Bluetooth See chapter Connecting with Ethernet (Requires BTS11 V1.6 or later) Female CONNECTING WITH RS232 SERIAL PORT Take the supplied Serial connection cable DB9 of DCM CU and connect the DB9 Female connector to RS232 port of the PC computer and connect the DB9 Male connector to RS232 TO COMPUTER port of DCM CU CONNECTING WITH BLUETOOTH When the driver is installed you can select the Bluetooth Serial port (COMXXX) in the serial communication list CREATE A BLUETOOTH CONNECTION Right-click the Bluetooth icon in the status bar. If no Bluetooth icon appears, click the arrow to show all hidden icons. If you still cannot find the Bluetooth icon, your computer is probably not equipped with Bluetooth. Click Show Bluetooth Devices Click Add a device

5 D.C.M Dynamic Contact Measurement User Manual page 4(22) Select DCM-XXXX * and click Next. DCM connected. If no DCM-XXXX * found verify that DCM-XXX is turned on and that you are not too far away from the unit (< 100 meters clear sight). * XXXX is the serial number on the unit. DCM-0001 Now the Bluetooth device is paired with a code. If your computer is equipped with Bluetooth version 2.1 and later, paired the devices together automatically with a code (see picture). O.B.S! If you have an older version of Bluetooth than 2.1, you must enter the pairing code to DCM. The code you enter is Click Next to continue. DCM-0001 When the wizard is finished, you can close the wizard by clicking the Close button. DCM-0001 To find out which COM port that DCM got right click on DCM- XXXX and click Properties. Click on the Services tab. Note the COM port DCM got (COMXXX).

6 D.C.M Dynamic Contact Measurement User Manual page 5(22) TROUBLESHOOT BLUETOOTH CONNECTION Right click on DCM-XXXX and click Troubleshoot. Follow the instructions in the wizard REMOVE THE BLUETOOTH CONNECTION Right click on DCM-XXXX and click Remove device. Click Yes in the dialog box to remove the connection.

7 D.C.M Dynamic Contact Measurement User Manual page 6(22) INSTALLING BLUETOOTH ADAPTER ON A LAPTOP THAT ALREADY HAS BLUETOOTH. Two Bluetooth adapters may not interact with Windows. Therefore, the internal adapter needs to be disabled before the USB Bluetooth adapter in connected. Open Device Manager by clicking the Start button, Control Panel, System and Security and then click Device Manager under System. If you are prompted for an administrator password or confirmation, follow the prompt. Expand Bluetooth Radios. Right-click the driver for your Bluetooth Receiver. Click Disable to disable the device. Click Yes in the following dialog. Then connect the Bluetooth USB Adapter to your computer's USB port. A new Bluetooth adapter together with Microsoft Bluetooth Enumerator will be shown under Bluetooth Radios

8 D.C.M Dynamic Contact Measurement User Manual page 7(22) INSTALLING BLUETOOTH ADAPTER ON COMPUTER WITH WINDOWS 10 Windows 10 installs the wrong driver for the LM540 Bluetooth adapter. To correct this do the following. Right click start and click Device Manager. Expand node Universal serial bus controllers. Select Generic Bluetooth Adapter and click Next. Right click CSR BlueCore Bluetooth and click Update Driver Software In the dialog click Browse my computer for driver software. In the dialog click Let me pick from a list of drivers on my computer. Windows will install the correct driver. Click Close CONNECTING WITH ETHERNET (REQUIRES BTS11 V1.6 OR LATER) At the moment Ethernet connection is not available. This will be added in BTS12

9 D.C.M Dynamic Contact Measurement User Manual page 8(22) 3.2 CONNECTION TO BREAKER POLES CONNECTION FOR SINGLE PHASE AND ONE CONTACT ELEMENT/PHASE Take the connection cable DCM-2 and Connect the M12, 8 pole Female connector to DCM UNIT 1 plug on DCM CU, connect the M12, 8 pole Male connector to CONNECT TO CONTROL UNIT plug on DCM 2. Connect the connection cable, breaker base to CURRENT and SENSE. Connect the connection cable, breaker T element to + CURRENT 1 and + SENSE 1. Put the DCM2 in the supplied bag and attach to the breaker base with the supplied straps. Attach the clamp of the connection cable, breaker base to the pole of breaker base. Attach the clamp of the connection cable, breaker T element to the pole of breaker element. Connection diagram one contact

10 D.C.M Dynamic Contact Measurement User Manual page 9(22) CONNECTION FOR SINGLE PHASE AND TWO CONTACT ELEMENTS IN SERIES/P HASE. Take the connection cable DCM-2 and Connect the M12, 8 pole Female connector to DCM UNIT 1 plug on DCM CU, connect the M12, 8 pole Male connector to CONNECT TO CONTROL UNIT plug on DCM 2. Connect the connection cable, breaker base to CURRENT and SENSE. Connect the connection cable, breaker T element to + CURRENT 1 and + SENSE 1. Connect the connection cable, breaker T element to + CURRENT 2 and + SENSE 2. Put the DCM2 in the supplied bag. Make sure that CURRENT 1 and + SENSE 1. Cable is to the Left of the bag. Make sure that CURRENT 2 and + SENSE 2. Cable is to the Right of the bag. Attach bag with DCM2 to the breaker base with the supplied straps on the bag. Attach the clamp of the connection cable, breaker base to the pole of breaker base. Attach the clamp of the left connection cable, breaker T element to the pole of left breaker T element. Attach the clamp of the right connection cable, breaker T element to the pole of right breaker T element. Connection diagram T element

11 D.C.M Dynamic Contact Measurement User Manual page 10(22) CONNECTION FOR 3-PHASES WITH TWO CONTACT ELEMENT IN SERIES/PHASE A B C Take the connection cable DCM-2 and Connect the M12, 8 pole Female connector to DCM UNIT 1 plug on DCM CU, connect the M12, 8 pole Male connector to CONNECT TO CONTROL UNIT plug on DCM 2. Connect the connection cable, breaker base to CURRENT and SENSE. Connect the connection cable, breaker T element to + CURRENT 1 and + SENSE 1. Connect the connection cable, breaker T element to + CURRENT 2 and + SENSE 2. Put the DCM2 in the supplied RED bag. Make sure that CURRENT 1 and + SENSE 1. Cable is to the Left of the bag. Make sure that CURRENT 2 and + SENSE 2. Cable is to the Right of the bag. Attach RED bag with DCM2 to the pole A breaker base with the supplied straps on the bag. Attach the clamp of the connection cable, breaker base to the pole of breaker base. Attach the clamp of the left connection cable, breaker T element to the pole of left breaker T element. Attach the clamp of the right connection cable, breaker T element to the pole of right breaker T element. Take the connection cable DCM-2 and Connect the M12, 8 pole Female connector to DCM UNIT 1 plug on DCM CU, connect the M12, 8 pole Male connector to CONNECT TO CONTROL UNIT plug on DCM 2. Connect the connection cable, breaker Connect the connection cable, breaker base to CURRENT and SENSE. Connect base to CURRENT and SENSE. Connect the connection cable, breaker T element to the connection cable, breaker T element to + CURRENT 1 and + SENSE 1. + CURRENT 1 and + SENSE 1. Connect the connection cable, breaker T Connect the connection cable, breaker T element to + CURRENT 2 and + SENSE 2. element to + CURRENT 2 and + SENSE 2. Put the DCM2 in the supplied YELLOW bag. Make sure that CURRENT 1 and + SENSE 1. Cable is to the Left of the bag. Make sure that CURRENT 2 and + SENSE 2. Cable is to the Right of the bag. Attach RED bag with DCM2 to the pole B breaker base with the supplied straps on the bag. Attach the clamp of the connection cable, breaker base to the pole of breaker base. Attach the clamp of the left connection cable, breaker T element to the pole of left breaker T element. Attach the clamp of the right connection cable, breaker T element to the pole of right breaker T element. Take the connection cable DCM-2 and Connect the M12, 8 pole Female connector to DCM UNIT 1 plug on DCM CU, connect the M12, 8 pole Male connector to CONNECT TO CONTROL UNIT plug on DCM 2. Put the DCM2 in the supplied BLUE bag. Make sure that CURRENT 1 and + SENSE 1. Cable is to the Left of the bag. Make sure that CURRENT 2 and + SENSE 2. Cable is to the Right of the bag. Attach RED bag with DCM2 to the pole C breaker base with the supplied straps on the bag. Attach the clamp of the connection cable, breaker base to the pole of breaker base. Attach the clamp of the left connection cable, breaker T element to the pole of left breaker T element. Attach the clamp of the right connection cable, breaker T element to the pole of right breaker T element.

12 D.C.M Dynamic Contact Measurement User Manual page 11(22) CONNECTION FOR ROGOWSKI COIL ON SINGLE PHASE AND ONE CONTACT ELEMENT/PHASE Rogowski coil can be used instead of connecting the electrical sense 1 and 2 to DCM2. The ratio of the Rogowski coil needs to have a peak range of A and 10 mv/ampere output. One model that has been successfully tested is Fluke i3000s Flex-24 AC Current Probe. Connection diagram one contact with Rogowski coil CONNECTION FOR ROGOWSKI COIL ON SINGLE PHASE AND TWO CONTACT ELEMENTS IN SERIES/PHASE. Rogowski coil can be used instead of connecting the electrical sense 1 and 2 to DCM2. The ratio of the Rogowski coil needs to have a peak range of A and 10 mv/ampere output. One model that has been successfully tested is Fluke i3000s Flex-24 AC Current Probe Connection diagram T element with Rogowski coil

13 D.C.M Dynamic Contact Measurement User Manual page 12(22) 4. OPERATION REMARK! All connections for testing according to chapter 3. CONNECTIONS assumed were performed. The user is assumed to be familiar with the PC-software BTS11. Se User manual BTS11 for more information of the PC-software. 4.1 PREPARATION Read Safety instructions in chapter 2. SAFETY before any connections. Make connections for DCM measurement as described in chapter 3. CONNECTIONS Start the PC-software BTS11 See User manual BTS11 for creating a test object and preparing for a test 4.2 OPEN TEST WINDOW Open the test window for selected test. Note! The test described below is done for one phase with two contact elements. There are 3 command buttons for operations that can be used with the DCM units Static pole res. Perform a static resistance measurement on a closed contact element. Selection of phase and contact element are done before the measurement take place. DCM at Open Perform a dynamic resistance/contact measurement at an OPEN operation. Selection of phase and contact element are done before the measurement take place. The trig signal for start of measurement is taken from the output voltage to the Trip coil. DCM at Close Perform a dynamic resistance/contact measurement at a CLOSE operation. Selection of phase and contact element are done before the measurement take place. Trig signal for start of measurement is taken from the output voltage to the Close coil.

14 D.C.M Dynamic Contact Measurement User Manual page 13(22) 4.3 STATIC RESISTANCE MEASUREMENT Pressing the command button Static pole res. opens a selection window for selection of phase and contact element. TEST PROCEDURE Select phase (if more than 1 phase) and contact elements to be tested in the selection boxes. Press command button Test to execute the test. RESULT AFTER TEST 4.4 DYNAMIC RESISTANCE MEASUREMENT Pressing the command button DCM at Open or DCM at Close opens a selection window for selection of phase and contact element. TEST PROCEDURE: Select phase (if more than 1 phase) and contact elements to be tested in the selection boxes. Press command button Ok to open the operation window OPERATION WINDOW. Press command button Operation (when enabled) to execute an Open operation Result after DCM operation at Open

15 D.C.M Dynamic Contact Measurement User Manual page 14(22) 5. TROUBLE SHOOTING Trouble shooting must only be performed by authorized and educated personnel. 5.1 NOT RECOGNIZE DCM UNITS - Check that the DCM-CU has main power - Check communication cable/connectors between PC and DCM-CU - Check communication cable/connectors between Switch analyser (SA10) and DCM-CU 5.2 NO TRIG - Check communication cable/connectors between DCM-CU and DCM NO MEASUREMENT - Check than cables/connectors for high current and voltage drop measurement are properly inserted inte the connectors. - Make sure that you have good connection with the clamps on the poles of the test object. If the poles are dirty they may may require cleaning for good connection. 6. MAINTENANCE Note! Service and maintenance must only be performed by authorized and educated personnel. 6.1 BEFORE USE OR ACCORDING TO COMPANY POLICY Maintenance Visual check of condition for cables and cable connectors Visual check of condition for connectors at DCM units 6.2 CHECK EVERY 12 MONTHS OR ACCORDING TO COMPANY POLICY Maintenance Visual check of condition for cables and cable connectors Visual check of condition for connectors at DCM units Perform calibration of unit. Solution Replace cable(s) or/and connector(s) with new if any damages are found Send the unit for repair if any damages are found. Solution Replace cable(s) or/and connector(s) with new if any damages are found Send the unit for repair if any damages are found. See chapter 7. Check and adjustment for check and calibration of DCM units. Or send the unit to for calibration. 7. CHECK AND ADJUSTMENT Note! Check and adjustments must only be performed by authorized and educated personnel. Check and adjustments of DCM-2 are done with the PC-software BTS11. The personnel that are allowed to make checks and calibration described in this chapter 7. Check and adjustment are assumed to familiarly with the PC-software BTS11. Refer to BTS11 User manual for operating instructions. Select Menu Service and function DCM-unit to get to the service window for DCM-2 All analogue inputs on the DCM-2 are software calibrated. Calibration can easy be done from a calibration wizard. All calibration constants and password for changing constants are saved in the DCM-2 unit. Note! Password to save new calibration at delivery is elcon Instrument needed Variable DC-voltage source: ± 0.125V DC, ± 1.25 VDC Voltage instrument: ± 1.25 VDC accuracy ± 0,02% Reference resistance ohm, accuracy <= 0.5% Principle of calibration Two points are measured at about 10 respective about 90% of full scale. The values are measured with both the DCM-2 and a connected reference instrument. With use of the equation for a straight line the new calibration constants are calculated. IMPORTANT! All voltage inputs and current outputs must be checked/calibrated. All voltage inputs must be checked/calibrated before Current outputs (resistance). (The voltage inputs are used as reference when calibrate the current outputs). 7.1 CALIBRATION APPROVAL Voltage inputs Sense 1, Sense 2 Approval: range V = 0.1 mv Approval: range V = 1.0 mv Current/Resistance measurement Current 1, Current 2 Make a resistance measurement on a calibrated resistance. Approval: range ohm 2 ohm Approval: range ohm 20 ohm

16 D.C.M Dynamic Contact Measurement User Manual page 15(22) 7.2 SERVICE WINDOW DCM Preparations: Make connections as for a normal measurement (Single pole). See chapter Connection for single phase and one contact element/phase for connections. Replace breaker element with a calibrated current shunt. Turn on the Switch analyser Start BTS11 software Click Menu Service and click function DCM-unit The Service window for DCM-unit will be displayed: Click tab for DCM-2 unit to be calibrated Press command button Calibrate to get to the calibration window 7.3 CALIBRATION WINDOW This window gives some general information of the connected DCM unit and the current used calibration constants. It also give the possibility to the user to set its own instrument number, set new password for calibration and start a calibration guide. The calibration constants can be change directly in the text boxes and saved with the Save button. It is strongly recommended that you use the command button Calibration wizard to make calibration instead of just changing the calibration constants in the test boxes. Command buttons: New Password Change of current password (The password is saved in DCM-2) Customer Settings Set a customer instrument number. Calibration Wizard Start a calibration guide Save Save changed calibration constants to DCM-2 Print Print all calibration constants for DCM-2 on a connected printer. Tip! Always printout a protocol after a calibration. Cancel Cancel the calibration guide. The calibration procedure is almost the same for all inputs. Press the command button Calibration Wizard to start the calibration guide. Follow the instructions for each dialogue box. 7.4 CALIBRATION WIZARD - VOLTAGE INPUTS After pressing the command button Calibration Wizard the window for the first step will be displayed. This window is used to select input(s) that shall be calibrated. Select the option button for the voltage input(s) you like to calibrate. It s recommended for voltage inputs that you calibrate both inputs Sense 1+2 at the same time. It will save calibration time! Important! Voltage inputs must be calibrated before current outputs. (The voltage inputs are used as reference when calibrate the current outputs) VOLTAGE CALIBRATION- STEP 2 This window is used to inform the user of the voltage source that must be available and where the connection shall be done. Connect the variable voltage source and press button Next to continue

17 D.C.M Dynamic Contact Measurement User Manual page 16(22) VOLTAGE CALIBRATION- STEP 3 This window is used to inform the user of the voltage setting and allow the user to type the value read from the connected reference instrument. The instrument box shows the current read value from DCM-2 Adjust the voltage source to the recommended voltage level Be aware of the sign of the voltage level Read the value from the reference instrument and type the value in the text box Press button next to continue VOLTAGE CALIBRATION- STEP 4 This window is the same as previous step. This time you shall set the second voltage value. Adjust the voltage source to the recommended voltage level Be aware of the sign of the voltage level Read the value from the reference instrument and type the value in the text box Be aware of the sign of the voltage level Press button Next to continue VOLTAGE CALIBRATION- STEP 5 This window shows the measurement result and allows the user to Save or Cancel the calibration. The instrument box shows the current read value with use of the new calculated calibration constants Press Save button to save the new calibration constants, a window will pop-up where you type the password ( elcon at delivery), date and signature. After the calibration constants are saved the same window appear again where you can choose if you like to Re-calibrate or Close the calibration guide. Press button Cancel to close the calibration without saving new calibration constants. 7.5 CALIBRATION WIZARD CURRENT OUTPUTS (RE SISTANCE) After pressing the command button Calibration Wizard the window for the first step will be displayed. This window is used to select input(s) that shall be calibrated. An indirect method is used for current calibration. The voltage inputs and a calibrated current shunt are used as reference at calibration of current. Select the option button for the current output you like to calibrate. IMPORTANT! It is required that the voltage inputs are calibrated before calibration of current. See chapter 7.4 Calibration wizard - Voltage inputs for calibration of voltage inputs CURRENT CALIBRATION - STEP 3 This window is used to inform the user about the connection of the reference resistance. The instrument box shows the current read value from DCM-2 Disconnect any connected resistance to the current terminals (Open circuit) Press button Next to continue.

18 D.C.M Dynamic Contact Measurement User Manual page 17(22) CURRENT CALIBRATION - STEP 4 This window is used to inform the user about the connection of the reference resistance Make connections for an ordinary resistance measurement. Connect a reference resistance ( ohm) to the current output cables. Connect the voltage measurement points on the reference resistor to the corresponding voltage inputs on the DCM-2 Type the value of the reference resistor in the text box Press button Next to make an ordinary resistance measurement CURRENT CALIBRATION - STEP 5 This window shows the measurement result and allows the user to Save or Cancel the calibration. Press Save button to save the new calibration constants. A window will pop-up where you type the password elcon, date and signature. After the calibration constants are saved the same window appear again where you can choose if you like to Re-calibrate or Close the calibration guide. Press button Cancel to cancel the calibration without saving new calibration constants 8. TRANSPORTATION/SCRAPPING/RECYCLING Before transportation remove all cables from DCM-CU and DCM-2 units when moving/transportation the equipment. Put the units and cables in intended locations in the test case Scrapping/Recycling of replaced components shall be done according to local rules and laws

19 D.C.M Dynamic Contact Measurement User Manual page 18(22) 9. SPECIFICATIONS The DCM units are used to perform dynamic contact measurements for High Voltage Circuit Breakers in sub stations with both side grounded. Static resistance measurement can also be performed for breakers with two contact element in series, both side grounded and the middle point not grounded. To be able to perform Static resistance measurement for breakers with one breaking element, only one side can be grounded. 9.1 DCM CU TECHNICAL SPECIFICATION Power supply Quantity 1 Marked Input Connector type IEC 950 entry module Fuses 2*2.5A slow Voltage range VAC, 50/60 Hz, Max70W Control output Quantity 3 Marked DCM UNIT 1, DCM UNIT 2, DCM UNIT 3 Connector type M12, 8 pole Female Standard IEC Manufacturer Phoenix contact Output voltage 18-24VDC Max output current 2.5A Communication RS485, baud rate K Baud Trig signal 5-24VDC Communication PC Quantity 1 Marked RS232 TO COMPUTER Connector type 9-pole D-sub, female Communication type RS232, baud rate K Baud Isolation 1000 V DC Communication SA Quantity 1 Marked RS-232 TO SWITCH ANALYZER Connector type: 9-pole D-sub, male Communication type: RS232, baud rate K Baud Isolation: 1000 V DC Communication Network Quantity 1 Marked ETHERNET Connector type: RJ45 Communication type: ETHERNET 100 Mb/s Communication Bluetooth Quantity 1 Marked BLUETOOTH Connector type BLUETOOTH ANTENNA SMA MALE Communication type Serial communication via Bluetooth version 2.1 Communication protocols Support for version Enhanced Data Rate (EDR) Backward compliant with Bluetooth version 2.0, 1.2, 1.1 Scope < 100 meters (Line of sight) Baud rate K baud Data size 8-bit Parity None Stop bits 1 Flow control None Environment Dimensions 165*50*175 (With*Height*Depth) Weight about 1.2 kg Operating temperature C Storing temperature C Relative humidity 20-85% non-condensing Altitude operating < m Altitude non-operating < m

20 D.C.M Dynamic Contact Measurement User Manual page 19(22) 9.2 DCM 2 TECHNICAL SPECIFICATION Control input Quantity 1 Marked CONNECT TO CONTROL UNIT Connector type M12, 8 pole Male Standard IEC Manufacturer Phoenix contact Charge voltage 18-24VDC Max charge current: 2.5A Communication RS485, baud rate K Baud Trig signal: 5-24VDC Current output Quantity Return Marked + CURRENT 1, + CURRENT 2, - CURRENT 1, 2 Connector type High current sockets with locking, nom 100A type: ID/B6AR-N-S (Manufacturer: Multi Contact) Output 0-1.6VDC, 0-225A (Depends of cable resistance) Current pulse time: max 200ms Current limitation: By cable resistance. Voltage Sense Input Quantity Reference Marked + SENSE 1, + SENSE 2, - SENSE 1, - SENSE 2 Connector type Isolated banana socket Measurement range 1 ± 0.15VDC Analog resolution 1 14 bits Resolution about 0, V DC / Bit Measurement range 2 ± 1.5VDC Analog resolution 2 14 bits Resolution about 0, V DC / Bit Measuring resistance Range1 750 µω ± 1 200A Measurement range mω ± A Measurement range mω ± 10 < 200A Sample rate 50KHz Environment Dimensions 165*50*175 (With*Height*Depth) Weight about 1.6 kg Operating temperature C Storing temperature C Relative humidity 20-85% non-condensing Altitude operating < m Altitude non-operating < m

21 D.C.M Dynamic Contact Measurement User Manual page 20(22) 9.3 DCM KIT (ITEM NUMBER S160) INCLUDES DCM CU Quantity 1 Dynamic Contact Monitoring DCM CU S161 DCM 2 Quantity 3 DCM Measuring unit S162 Connection cable DCM-2 Quantity 5 Multi cable 8 pole M12 plug in connector Standard IEC Manufacturer Phoenix contact Part number SAC 8P-M12MS/10- PUR/M12FS SH Length 10 meters S163 Connection cable, breaker T element Quantity 6 special designed cable for current and voltage drop measurement. Length 3 meters S171 Connection cable, breaker base Quantity 3 special designed current and reference for voltage drop measurement. Length 0.3 meters S170 Mains power connection Quantity 1 Standard Europe mains power cord Type CEE 7/7 to IEC C13 250V/10A, L=2m Length 2 meters S201 Ferrite for mains power cord Quantity 1 Broadband EMI Ferrite Split/Snap-On Core in Plastic Cases Value MHz Manufacturer Laird Technologies Part number 28A0640-0A2 Weight 24 Grams Serial connection cable DB9 Quantity 2 Standard RS232 cable DB9 male/female Length 2 meters S202

22 D.C.M Dynamic Contact Measurement User Manual page 21(22) Bluetooth antenna Quantity 2 Broadband RP-SMA Value MHz Manufacturer Laird Technologies Part number MAF94028-WRR2400-RPSMA-B Frequency GHz Gain 1.3 dbi (2.45 GHz) Polarization Vertical, Omnidirectional Nominal Impedance 50 ohms VSWR 2:1 max across all bands Size Length or USB Bluetooth 2.1 EDR stick Quantity 1 BLUETOOTH 2.1 USB ADAPT, CLS1, ANT, IVT Manufacturer LM TECHNOLOGIES Part number LM Connector type USB2 and BLUETOOTH ANTENNA SMA MALE Communication type Serial communication via Bluetooth version 2.1 Communication protocols Support for version Enhanced Data Rate (EDR) Backward compliant with Bluetooth version 2.0, 1.2, 1.1 Scope < 100 meters (Line of sight) S202F Export restrictions This product is subject to export control when exported from the European Union. Valid countries outside the E.U. is Australia, Japan, Canada, New Zeeland, Norway, Switzerland, Liechtenstein and USA. Transporting case Quantity 1 With wheels and retractable handle S113 Soft cable bag Quantity 1 Bag for cables S114 DCM2 Fastening kit Quantity 3 Hanging straps S172

23 D.C.M Dynamic Contact Measurement User Manual page 22(22) 9.3 DECLARATION OF CONFORMITY 10. REVISIONS Revision 0 Date Revision 1 Date Revision 2 Date Revision 3 Date Revision 4 Date

DCM Dynamic Contact Measuring

DCM Dynamic Contact Measuring DCM Dynamic Contact Measuring The fast and safe way of testing your HV Circuit breakers using With the new tool for the Elcon products Switch Analyzers SA10 and SA5, the DCM (Dynamic Contact Mesurment),will

More information

Switch Analyzer SA10 & DCM Dynamic Contact Measuring

Switch Analyzer SA10 & DCM Dynamic Contact Measuring Switch Analyzer SA10 & DCM Dynamic Contact Measuring Switch Analyzer SA10 SA10 The SA10 unit is designed to be used together with a notebook computer even if some fundamental test can be done stand-alone.

More information

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Mini Clamps: Part Number 111.7015 PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Description 10 ma-to-20 A or 100 ma-to-200 A. Switchable range mini clamp. 40 Hz 20 khz 4 x mini

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels 4 additional analog

More information

Line Impedance Stabilization Network (LISN)

Line Impedance Stabilization Network (LISN) Model 3816/2 Line Impedance Stabilization Network (LISN) User Manual ETS-Lindgren Inc. reserves the right to make changes to any product described herein in order to improve function, design, or for any

More information

A P P L I C A T I O N

A P P L I C A T I O N Circuit Breaker timing test set 16 timing channels Motion and speed analyzer Built-in 200 A microohmmeter Up to 4 trip/close coils control Static and dynamic contact resistance measurement Suitable for

More information

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. The TRSUN is the complete solution for the remote monitoring of photovoltaic plants. Monitoring of inverters and string combiner boxes (up to 64 devices); Complete configuration of the monitoring system

More information

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System

DRTS 3 PLUS Advanced Protection Relay Test Set and Measurement System Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

CBA 1000 CHARACTERISTICS

CBA 1000 CHARACTERISTICS Circuit Breaker Analyzer and Microhmmeter Circuit Breaker timing test set. Built-in 200 A microhmmeter. 16 timing channels. Up to 4 trip/close coils control. Motion and speed analyzer. Static and dynamic

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Versatile, Automatic RCL Meters

Versatile, Automatic RCL Meters Versatile, Automatic RCL Meters Technical Specifications PM 6306 / PM 6304 / PM 6303A PM 6306 and PM 6304 Versatile component measurement and testing Easy to use, at-a-glance display Test frequencies,

More information

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT66 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

CBA HV Circuit Breaker Analyzer and Microhmmeter

CBA HV Circuit Breaker Analyzer and Microhmmeter CBA 2000 HV Circuit Breaker Analyzer and Microhmmeter Built-in 200 A microhmmeter Up to 18 main and 18 resistive contact inputs 12 auxiliary timing inputs Up to 4 trip/close coils control Motion and speed

More information

Model A Mini AC/DC Clamp Meter. User's Guide

Model A Mini AC/DC Clamp Meter. User's Guide Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,

More information

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is

More information

USER'S MANUAL DCL-650

USER'S MANUAL DCL-650 USER'S MANUAL Clamp on Multimeter - Compact Design True RMS AC/DC DCL-650 CIRCUIT-TEST ELECTRONICS www.circuittest.com Safety International Safety Symbols This symbol, adjacent to another symbol or terminal,

More information

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 05-2017 Accessories for PQ-Box 100 & 150 & 200 Page 1 Rogowski coil set CAT IV 600V Current range: 1A to 3000A RMS; Accuracy: 1%

More information

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter Circuit Breaker Analyzer and MicroOhmmeter Circuit Breaker timing test set. 16 timing channels. Up to 4 trip/close coils control. Motion and speed analyzer. Suitable for EHV, HV and MV circuit breakers.

More information

MJÖLNER 200 Micro-ohmmeter

MJÖLNER 200 Micro-ohmmeter Fully automatic testing Micro processor controlled Safe test DualGround and Remote control True DC ripple free current Lightweight suitcase withstands the impact of water, dust or sand Built in thermal

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This

More information

EGIL Circuit breaker analyzer

EGIL Circuit breaker analyzer EGIL Suitable for testing timing and travel on all circuit breakers with single interrupter per phase Extremely easy-to-use and reliable Two separate timing channels for measurement of auxiliary contacts

More information

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter

More information

CT-8000 S3. digital circuit breaker analyzer

CT-8000 S3. digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer Product Overview The CT-8000 S3 is Vanguard's fourth generation EHV circuit breaker analyzer. The CT-8000 S3 is available

More information

EGIL Circuit breaker analyzer

EGIL Circuit breaker analyzer EGIL Circuit breaker analyzer EGIL Circuit breaker analyzer Suitable for testing timing and travel on all circuit breakers with single interrupter per phase Extremely easy-to-use and reliable Two separate

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300 Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 & 300 Jun-18 Accessories for PQ-Box 100 & 150 & 200 & 300 Page 1 Rogowski coil set CAT IV 600V Current range: 1A to 3000A RMS,

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

DRTS 66 can test all the following relays

DRTS 66 can test all the following relays Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs

More information

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT DKG-210 UNIVERSAL INTERNET GATEWAY UNIT AC & DC SUPPLY VERSIONS DESCRIPTION The DKG-210 is designed for internet monitoring and control of industrial devices using different protocols through the RAINBOW

More information

Digital Clamp Meter User Manual

Digital Clamp Meter User Manual Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...

More information

ANALYSER OF 3-PHASE POWER NETWORK PARAMETERS ND1 TYPE

ANALYSER OF 3-PHASE POWER NETWORK PARAMETERS ND1 TYPE ANALYSER OF 3-PHASE POWER NETWORK PARAMETERS ND1 TYPE First Start LZAE Lumel S.A. Sulechowska 1 65-022 Zielona Góra Poland (UE) Caution! Before approaching to fit and activate the device, you must become

More information

We take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories

We take care of it. Mobile Power Quality Analyzers. PQ-Box 100/150/200. Accessories We take care of it. Mobile Power Quality Analyzers PQ-Box 100/150/200 Accessories Rogowski coil set Current range: 1 A to 3000 A RMS; Set of 4 pieces Accuracy: 1%; Size: 61 cm (24 ); Diameter = 194 mm

More information

CT-8000 S3 digital circuit breaker analyzer

CT-8000 S3 digital circuit breaker analyzer CT-8000 S3 digital circuit breaker analyzer Vanguard Instruments Company, Inc. www.vanguard-instruments.com CT-8000 S3 digital circuit breaker analyzer Product Overview The CT-8000 S3 is Vanguard's fourth

More information

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2.

Soft Starter Remote Operator. Section 1.0 Introduction 1.1 Important user information General Manual description...2. Section 1.0 Introduction 1.1 Important user information... 2 1.2 General... 2 1.3 Manual description...2 Contents Section 2.0 Specification 2.1 General technical data...3 2.2 Dimensions...3 Section 3.0

More information

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389 User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further

More information

High Voltage Power Supplies

High Voltage Power Supplies Source voltages up to 5kV and 10kV 1µA current measurement resolution Multi-channel programmable DC power supplies Low noise for precision sourcing and sensitive measurements; selectable filters reduce

More information

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc. User s Guide RP7000S Series Single-Ended Active Probe Nov. 2013 RIGOL Technologies, Inc. Guaranty and Declaration Copyright 2013 RIGOL Technologies, Inc. All Rights Reserved. Trademark Information RIGOL

More information

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.

More information

T1/E1 Channelized Gigabit Router

T1/E1 Channelized Gigabit Router OnSite 2884 Channelized Gigabit Router Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use in an industrial

More information

EGIL Circuit breaker analyzer

EGIL Circuit breaker analyzer Suitable for testing timing and travel on all circuit breakers with single interrupter per phase Extremely easy-to-use and reliable Two separate timing channels for measurement of auxiliary contacts Analog

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

1690-Series Logic Analyzers

1690-Series Logic Analyzers 1690-Series Logic Analyzers Quick Start/Installation Installation 2 Making a measurement 4 Snap to Edge Markers 6 Left-Click Menus 7 Tree Structure Labels 7 Offline Analysis 8 Marker Overview 8 Tool Tips

More information

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction ACOPOSinverter P74 User's Manual Version: 2.20 (August 2016) Model no.: MAACPIP74-ENG Original instruction All information contained in this manual is current as of its creation/publication. We reserve

More information

Mini Digital Multimeter

Mini Digital Multimeter User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER

MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER MCCB-250 MOLDED-CASE CIRCUIT BREAKER TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 January 2015 Revision

More information

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800) Digital 10A Micro-Ohmmeters Models 6240 & 6250 Measure low resistance with high accuracy Selectable test current and resistance ranges 0.1µΩ resolution Simple one button press-to-start operation Software

More information

Leased-Line Extenders over IP

Leased-Line Extenders over IP SmartNode 2290 Series Leased-Line Extenders over IP Quick Start Guide Important This is a Class A device and is intended for use in a light industrial environment. It is not intended nor approved for use

More information

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT65 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Mini Digital Multimeter

Mini Digital Multimeter User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series

More information

Circuit Breaker Analyzer & Timer CAT31

Circuit Breaker Analyzer & Timer CAT31 Simple & easy to operate 3 timing channels for main and resistive contacts 3 timing channels for auxiliary inputs Open & Close coils current measurement Resistance measurement of pre-insertion resistors

More information

User's Guide. Extech AM A AC Analog Clamp Meter

User's Guide. Extech AM A AC Analog Clamp Meter User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.

More information

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.

More information

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges Digital 10A Micro-Ohmmeters Models 6240 & 6250 Measure low resistance with high accuracy Selectable test current and resistance ranges 0.1µΩ resolution Simple one button press-to-start operation Software

More information

2 in 1 LAN Tester and Multimeter Model:

2 in 1 LAN Tester and Multimeter Model: 2 in 1 LAN Tester and Multimeter Model: 72-8495 1 IMPORTANT SAFETY INFORMATION Please read these instructions carefully before use and retain for future reference. This instrument is designed and manufactured

More information

DATE: 18/01/2011 DOC.SIE10166 REV.10 CIRCUIT BREAKER ANALYZER AND MICROOHMMETER MOD. CBA1000

DATE: 18/01/2011 DOC.SIE10166 REV.10 CIRCUIT BREAKER ANALYZER AND MICROOHMMETER MOD. CBA1000 DATE: 18/01/2011 DOC.SIE10166 REV.10 CIRCUIT BREAKER ANALYZER AND MICROOHMMETER MOD. CBA1000 Doc. SIE10166 Rev. 10 Page 2 of 28 REVISIONS SUMMARY VISA N PAGE DATE 1 All 22/07/2005 Preliminary issue Lodi.

More information

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL: 61-795 The Service Information provides the following: Precautions and safety information Specifications Performance test procedure Calibration and calibration

More information

User's Guide. Digital Multimeter. Model MN42

User's Guide. Digital Multimeter. Model MN42 User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and

More information

3 analog linear/rotary transducers and 3 digital transducers inputs for travel/ speed analysis

3 analog linear/rotary transducers and 3 digital transducers inputs for travel/ speed analysis The ultimate all-in-one circuit breaker analyzer: safer, faster and more accurate than ever. It allows any timing test, motion and speed analysis, multiple contemporary static and dynamic contact resistance

More information

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual

Bluetooth to RS-232&RS422/485. EX-9132B/BI Bluetooth Adapter Operation Manual Bluetooth to RS-232&RS422/485 EX-9132B/BI Bluetooth Adapter Operation Manual First Edition, Jun 2008 Table of Contents 1. Introduction 2 2. Package checklist 3 3. Product Specification 4 4. Product Panel

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter.

Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. Document Name : User Manual for SC10B : RS232 to Bluetooth Converter. SC10B is Bluetooth V.2.0-certified and is backward compatible with v1.1/1.2 devices. You can connect between your computers (Master)

More information

User Manual. Printer P-52RUE

User Manual. Printer P-52RUE User Manual P-52RUE Overview 3 4 2 5 1 6 13 12 7 11 10 9 8 Overview Table 1 Paper feed button 8 Ethernet RJ45 connection 2 Status indicator 9 USB device connection 3 Paper cutter 10 RS232 connection 4

More information

Hubport USB HUB Installation Guide Models: Hubport/4 Hubport/7 Hubport/14 /c Models: Hubport/4c Hubport/7c Hubport/4c DC Hubport/7c DC

Hubport USB HUB Installation Guide Models: Hubport/4 Hubport/7 Hubport/14 /c Models: Hubport/4c Hubport/7c Hubport/4c DC Hubport/7c DC Hubport USB HUB Installation Guide Models: Hubport/4 Hubport/7 Hubport/14 /c Models: Hubport/4c Hubport/7c Hubport/4c DC Hubport/7c DC www.digi.com Table of Contents Table of Contents...1 Introduction

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Series Watt DC Power Supplies

Series Watt DC Power Supplies Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Series 2268 850-Watt DC Power Supplies Specifications SPECIFICATION CONDITIONS This document contains

More information

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no. 20 751 979 Distributor: Manufacturer: METREL d.d. Ljubljanska cesta 77 1354 Horjul

More information

Digital Clamp-on Meter Instruction Manual

Digital Clamp-on Meter Instruction Manual 265 Digital Clamp-on Meter Instruction Manual TABLE OF CONTENTS A. INTRODUCTION 1. Congratulations...3 2. Product Description...3 3. Declaration of Conformity...4 B. SAFETY CONSIDERATIONS...5 C. TECHNICAL

More information

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model R5010. TRMS Digital Multimeter. Instruction Manual INSTRUMENTS Model R5010 TRMS Digital Multimeter Instruction Manual Table of Contents Safety...3-4 IEC1010 Overvoltage Installation Category... 3 Warnings... 4 Features... 5 Specifications...5-8 Instrument

More information

REVISION HISTORY REV DESCRIPTION SALES RFS DATE A INITIAL RELEASE MS /20/2011 B UPDATE LABEL: CHANGE CQC PSE NAME TO COGNEX K.K.

REVISION HISTORY REV DESCRIPTION SALES RFS DATE A INITIAL RELEASE MS /20/2011 B UPDATE LABEL: CHANGE CQC PSE NAME TO COGNEX K.K. REVISION HISTORY REV DESCRIPTION SALES RFS DATE A INITIAL RELEASE MS 20784 4/20/2011 B UPDATE LABEL: CHANGE CQC PSE NAME TO COGNEX K.K. MS 4/27/2011 APPROVED HM HM Customer Approval of Specification: Please

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www. Model R5010 TRMS Digital Multimeter Instruction Manual reedinstruments www com Table of Contents Safety...3-4 Features... 5 Specifications...5-8 Instrument Description...8-9 Operating Instructions...10-16

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43

USB COMMUNICATIONS INTERFACE LOOP LINK Contents. Side 1. Page 15. Page 29. Seite 43 USB COMMUNICATIONS INTERFACE LOOP LINK 5909 DK Side 1 Contents 5 9 0 9 L o o p L i n k U S B C o m m u n i c a t i o n s I n t e r f a c e N o. 5 9 0 9 V 1 0 1 - I N ( 1 0 0 7 ) F r o m s e r. n o. 0 4

More information

Back-UPS RS APC Back-UPS RS 800VA 120V Black

Back-UPS RS APC Back-UPS RS 800VA 120V Black Back-UPS RS APC Back-UPS RS 800VA 120V Black APC Back-UPS RS, 540 Watts / 800 VA,Input 120V / Output 120V Includes: CD with software, Cord management straps, Free trial of anti-virus : firewall : email

More information

MTP INSTRUCTION MANUAL

MTP INSTRUCTION MANUAL DT-118B MTP INSTRUCTION MANUAL Pocket Autoranging Digital Multimeter 3 in 1 Model MTP-1025 Auto Ran ging DMM Hz% A OFF V AU TO PO WER OFF MTP Instruments Table of Contents Introduction Page 1 Features

More information

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK 1 GENERAL... 2 1.1 Description... 2 2 INPUT REQUIREMENTS... 2 2.1 Input Conditions... 2 2.2 AC Inrush Current... 2 3 OUTPUT REQUIREMENTS... 2 4 MECHANICAL... 3 4.1 Enclosure And Layout... 3 4.2 Input and

More information

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I Table of Contents 1 Welcome Introducing the Avaya Wireless LAN 1-1 About the Access Point-I 1-2 Finding Information 1-3 2 Install your Access Point-I Overview 2-1 Verify Kit Contents 2-2 Write Down Product

More information

Circuit Breaker Analyzer & Timer CAT-P

Circuit Breaker Analyzer & Timer CAT-P Circuit Breaker Analyzer & Timer CAT-P Portable (1,4 kg / 3.1 lbs) Internal battery power supply Online measurement (First trip test) Offline measurement DC voltage and DC current measurement Touch screen

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

epowerswitch-8 Power Management Master Slave User's Guide

epowerswitch-8 Power Management Master Slave User's Guide epowerswitch-8 Power Management Master Slave User's Guide epowerswitch-8 epowerswitch-8 is a couple of power control units made of a Master named epowerswitch-m8 and a slave named epowerswitch-s8. epowerswitch-m8

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors

D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to

More information

SGT-600 SAFETY GROUND TESTER

SGT-600 SAFETY GROUND TESTER SGT-600 SAFETY GROUND TESTER USER S MANUAL Vanguard Instruments Company, Inc. 1520 S. Hellman Ave. Ontario, California 91761, USA TEL: (909) 923-9390 FAX: (909) 923-9391 April 2015 Revision 1.0 SAFETY

More information

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before

More information

Thermoelectric Cooler Controller TED1000

Thermoelectric Cooler Controller TED1000 Thermoelectric Cooler Controller TED1000 Operating Instructions MANUAL-TED1000-1.0 Aug 2015 Rev.1 2 Contents 1 General... 4 1.1 Warranty and Assistance... 4 1.2 Maintenance... 4 1.3 General Safety Considerations...

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V

EZ864 G. Telit Cellular GSM/UMTS Engine. Hardware guide Version: Update: 27. APR.2009 EZ864 G_Hardware Guide_V EZ864 G Telit Cellular GSM/UMTS Engine Hardware guide Version: 04.01 Update: 27. APR.2009 EZ864 G_Hardware Guide_V4. - 1 - Hardware Interface Description 1. Hardware Features of the EZ864 G Feature Implementation

More information

TETRIS 2500 High Impedance Active Probe. Instruction Manual

TETRIS 2500 High Impedance Active Probe. Instruction Manual TETRIS 2500 High Impedance Active Probe Instruction Manual Copyright 2018 PMK GmbH All rights reserved. Information in this publication supersedes that in all previously published material. Specifications

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

MJÖLNER 600 Microhmmeter

MJÖLNER 600 Microhmmeter Microhmmeter A Megger Group Company Microhmmeter The MJÖLNER 600 is designed to measure the resistance of circuit breaker contacts, bus-bar joints, contact elements in bus-bars and other high-current links.

More information

Circuit Breaker Analyzer & Timer CAT-P

Circuit Breaker Analyzer & Timer CAT-P Circuit Breaker Analyzer & Timer CAT-P Portable (1,4 kg / 3.1 lbs) Internal battery power supply Online measurement (First trip test) Offline measurement DC voltage and DC current measurement Touch screen

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

Optical Multiplexer. Quick Start Guide

Optical Multiplexer. Quick Start Guide Optical Multiplexer Quick Start Guide Part Number: 07M1195-QS, Rev. A Revised: February 12, 2009 Sales Office: +1 (301) 975-1000 Technical Support: +1 (301) 975-1007 E-mail: support@patton.com WWW: www.patton.com

More information