Universal sensors and switches, universal output devices

Size: px
Start display at page:

Download "Universal sensors and switches, universal output devices"

Transcription

1 AnyWireASLINK System Products Guide ASLINKTERMINAL [ASLINK Small Terminal Block Terminal] BL29 B-0F -V50 EURO block type The Products Guide describes individual products. Refer to the Guide as necessary. Function List Model ASLINKTERMINAL four-wire (isolated) cable type Compatible with a 3-wire sensor (input) Connection targets Notes on use To set any address, an Address writer ARW-04 (Ver or higher), ARW-03 (Ver or higher) is required. Please prepare it separately. [Notes on Safety] Specifications -point input/-point output -point input/-point output 4-point input/4-point output (hybrid) 4-point input/4-point output (hybrid) Universal sensors and switches, universal output devices Slave unit voltage reduction Sensing level reduction Functions I/O disconnection Precautions that must be observed in order to use this system safely are indicated as shown below. You must observe these precautions. WARNING A WARNING indicates a potentially hazardous situation which, if not handled correctly, could result in death or serious injury. I/O short circuit I/O reduction A indicates a potentially hazardous situation which, if not handled correctly, may result in personal injury or property damage. -BL29*B0*F****V50 1/17- Smallsized WARNING System Safety This system is intended for general industrial applications. It does not have functions for supporting applications requiring higher levels of safety such as safety-related devices or accident prevention systems. The product must not be used for these purposes. Always turn off the power before attempting to mount or replace. Prolonged continuous flow of a rated load current or higher or a transit current due to load short-circuit, etc., in the hybrid unit including the output unit and the output circuit may result in smoking or firing. An external safety device such as a fuse must be installed. System Use a stable, DC. Use of an unstable may cause problems with the system. Separately route high-voltage and power cables Although the AnyWireASLINK has a high noise margin, keep the transmission line and I/O cables away from high-voltage and power cables. Connectors and s Pay careful attention to the length and installation of cable wiring to ensure that connectors and cables are neither overloaded nor disconnected. Make sure to prevent any metal objects from getting inside the connectors or the blocks. Short-circuits caused by metal objects or mis-wiring are likely to damage the device. Do not impose any external loads on the units. Doing so may cause a failure. Do not disconnect or reconnect between the transmission line and slave units. A malfunction may occur. Use the AnyWireASLINK within the range of the specifications and conditions shown below. [Warranty] Warranty period The warranty on the delivered Product shall continue to be effective for one (1) year after the delivery thereof to a location as designated by the original owner. Scope of warranty Should a defect occur in any part of the Product during the foregoing warranty period when it is used normally in acordance with the specifications described in this User's Manual, the Company shall replace or repair the defect free of charge, except when it arises as a result of: [1] Misuse or abuse of the Product by the owner; [2] Fault caused by other than the delivered Product; [3] The unauthorized modification or repair of the Product by any person other than the Company's personnel; [4] Any unusual force of nature, disaster or other cause beyond the Company's control. The term "warranty," as used herein, refers to the warranty applicable to the delivered product alone. The Company shall not be liable for consequential or incidental damages resulting from any malfunction. Repair at cost After the expiration of the warranty period, the owner shall be responsible for all costs and expenses incurred for the troubleshooting and repair of the Product. Even during the warranty term, the Company shall repair any defects arising from causes other than within the scope of the warranty as specified above, at the owner's cost.

2 [How to connect AnyWireASLINK] The AnyWireASLINK can employ a two-wire or four-wire selectively depending on the load current. This Products Guide describes a four-wire (isolated). If the load current is small, using a two-wire (non-isolated) allows for achieving simplified wiring without local. In the case of prioritizing the sites of concentrated loads and/or the number of connections, hybridization with a four-wire (isolated), which supports local, is also possible. Make sure to use a four-wire (isolated) in the case of input and load driving using an external. In the case of hybridization, refer to the Two-Wire (Non-Isolated) Terminal Products Guide separately. [Connection Example] AnyWireASLINK master General-purpose filter Red: Black: ASLINK filter Red: Black: Relationship between the size and length of the transmission line and the supply current (Table 1) Size of the transmission line (, ) 1.25mm mm 2 Supply current on the transmission line (, ) Total length 50m or less Total length 50m to 100m MAX 2A MAX 1.2A MAX 1A MAX 0.A Total length 100m to 200m MAX 0.5A MAX 0.3A 0.5mm 2 MAX 0.A MAX 0.4A MAX 0.2A DC* * Make sure to use a DC stabilized for the to be connected. * When complying with the UL Standard, make sure to use a DC stabilized of NEC Class 2 Output. Dedicated flat cable 1.25mm 2 (four-wire) Red: Black: If the load consumption current is large, a four-wire (isolated) can be selected. This can correspond to I/O of the controller with an external. points Red: Black: - Refer to Table 1 so that the size and length of the transmission line and the allowable supply current lie within an appropriate range. - Connect the same symbols (, ) correctly between the AnyWireASLINK master and each device. - The branching length or branch number has no limitation. - Include the length of the cable provided with the in the total line length. - Connect the terminator BT0 (polar) to the, farthest from AnyWireASLINK master. 4P link connector is convenient for branching. points The sum of the portions of, is the total line length. General-purpose filter The branching has no limitation. Black: Red: Red: Black: DC* Black: Red: BT0 AnyWireASLINK terminator One terminator should be connected to the, farthest from the AnyWireASLINK master. Connect it correctly so as not to set the wrong polarity. [Installation Location] -Location where the unit is not subject to vibration or shock -Location where the unit is not directly exposed to dust -Location where the main body is not directly exposed to conductors such as waste metal and sputter -Location where humidity is not condensed -Location where the atmosphere is free of corrosive gas, flammable gas and sulfur -Location where the unit is removed from high-voltage or high-current cables -Location where the unit is removed from cables and controllers that generate servo, inverter or other high-frequency noise. -BL29*B0*F****V50 2/17-

3 ~ [Precautions for use with 4-Wire (Insulated) Terminal] If any of the side-by-side lines of,, and exceeds the total length of 50m in a system to be supplied, serially connect the ASLINK filter [Type ANF-01] or filter of COSEL Co., Ltd. [Type EAC-0-472] to and in the starting position of the side-by-side lines. This will improve noise resistance, reduce the impact of crosstalk by transmission signals and stabilize the signals. In any case of to the entire system from the master driving or from the local, insert a filter. Insert the ASLINK filter [Type ANF-01] regardless of installation method and distance when complying with CE Standard. Filter allowable power current Model Type Allowable power current ASLINK filter ANF-01 MAX 5A/ DC Filter of COSEL Co., Ltd. EAC MAX A/ DC AnyWire Type: ANF-01 Connection example 1Power supply to the entire system AnyWireASLINK master 2-wire LG General-purpose power supply filter (Use it if necessary.) POWER IN SLAVE PE ANF-01 If any of the side-by-side lines of,, and exceeds the total length of 50m BT0 FG N L DC stabilized ~ 2Local and branching 2-wire 2-wire AnyWireASLINK master FG N L LG DC stabilized POWER IN General-purpose power supply filter (Use it if necessary.) SLAVE PE ANF-01 If any of the side-by-side lines of,, and exceeds the total length of 50m POWER IN SLAVE L N FG PE ANF-01 DC stabilized General-purpose power supply filter (Use it if necessary.) A BT0 ~ B If (A+B) of the side-by-side lines of,, and exceeds the total length of 50m -BL29*B0*F****V50 3/17-

4 ~ COSEL Co., Ltd. Type: EAC Connection example 1Power supply to the entire system AnyWireASLINK master * When using this filter, please be careful of the positions of LOAD and LINE. 2-wire LG General-purpose filter (Use it if necessary.) LOAD LINE PE EAC-0-472* If any of the side-by-side lines of,, and exceeds the total length of 50m BT0 FG N L DC stabilized ~ 2Local /branching * When using this filter, please be careful of the positions of LOAD and LINE. 2-wire 2-wire AnyWireASLINK master FG N L LG General-purpose filter (Use it if necessary.) DC stabilized LOAD LINE PE EAC-0-472* If any of the side-by-side lines of,, and exceeds the total length of 50m L N FG DC stabilized LOAD LINE PE EAC-0-472* General-purpose power supply filter (Use it if necessary.) A BT0 ~ B If (A+B) of the side-by-side lines of,, and exceeds the total length of 50m -BL29*B0*F****V50 4/17-

5 [Type] Terminal BL29SB-0F-V50 BL29XB-0F-V50 BL29PB-0F-V50 -point input 4-point input, 4-point output -point output BL29SB-0FS-V50 BL29XB-0FS-V50 BL29PB-0FS-V50 -point input 4-point input, 4-point output -point output Standard block M3, 7.2mm pitch Width mm, Y, round BL29SB-0F-3-V50 BL29XB-0F-3-V50 BL29PB-0F-3-V50 -point input 4-point input, 4-point output -point output BL29SB-0FS-3-V50 BL29XB-0FS-3-V50 BL29PB-0FS-3-V50 -point input 4-point input, 4-point output -point output Spring block 5.0mm pitch Twisted wire, ferrule BL29SB-0F-11-V50 BL29XB-0F-11-V50 BL29PB-0F-11-V50 -point input 4-point input, 4-point output -point output BL29SB-0FS-11-V50 BL29XB-0FS-11-V50 BL29PB-0FS-11-V50 -point input 4-point input, 4-point output -point output EURO block 5.0mm pitch Twisted wire, ferrule [Name of each part] Standard block Cover mounting hole Mounting hole Transmission line connecting cable ALM LINK Infrared port Input/output display Cover mounting hole ALM LINK Infrared port Input/output display Spring block Mounting hole Transmission line connecting cable ALM EURO block Cover mounting hole Mounting hole LINK Infrared port Input/output display Transmission line connecting cable -BL29*B0*F****V50 5/17-

6 [Terminal Layout (Standard Terminal Block)] (Input) BL29SB-0F -V50 (Output) BL29PB-0F -V50 (red) : transmission line (+) (black) : transmission line (-) (green) : for, connected load drive (+) (white) : for, connected load drive (-) on the transmission line connecting cable side and on the block are internally connected. on the transmission line connecting cable side and on the block are internally connected. And s with the same names are internally connected. to on the block can be used as a sensor power or power for output devices. (2 points, 1 common) The total passing current of -: maximum 0.A Terminal blocks 0 to 7 are s that connect input devices such as sensors, switches, LEDs and solenoid valves. (Input/output mixed) BL29XB-0F -V50 (red) : transmission line (+) (black) : transmission line (-) (green) : for, connected load drive (+) (white) : for, connected load drive (-) IN0 IN1 IN2 IN on the transmission line connecting cable side and on the block are internally connected. on the transmission line connecting cable side and on the block are internally connected. And s with the same names are internally connected. to on the block can be used as a sensor power or power for output devices. (2 points, 1 common) The total passing current of -: maximum 0.A Terminal blocks IN0 to 3 are s that connect input devices such as sensors and switches. Terminal blocks 0 to 3 are s that connect output devices such as LEDs and solenoid valves. IN0 IN1 IN2 IN Input output -BL29*B0*F****V50 /17-

7 [Terminal Layout (Spring Terminal Block)] (Input) BL29SB-0F -3-V50 (Output) BL29PB-0F -3-V50 (red) : transmission line (+) (black) : transmission line (-) (green) : for, connected load drive (+) (white) : for, connected load drive (-) on the transmission line connecting cable side and on the block are internally connected. on the transmission line connecting cable side and on the block are internally connected. And s with the same names are internally connected. to on the block can be used as a sensor power or power for output devices. (2 points, 1 common) The total passing current of -: maximum 0.A Terminal blocks 0 to 7 are s that connect input devices such as sensors, switches, LEDs and solenoid valves. (Input/output mixed) BL29XB-0F -3-V50 (red) : transmission line (+) (black) : transmission line (-) (green) : for, connected load drive (+) (white) : for, connected load drive (-) IN0 IN1 IN2 IN on the transmission line connecting cable side and on the block are internally connected. on the transmission line connecting cable side and on the block are internally connected. And s with the same names are internally connected. to on the block can be used as a sensor power or power for output devices. (2 points, 1 common) The total passing current of -: maximum 0.A Terminal blocks IN0 to 3 are s that connect input devices such as sensors and switches. Terminal blocks 0 to 3 are s that connect output devices such as LEDs and solenoid valves. IN0 IN1 IN2 IN Input Input output output -BL29*B0*F****V50 7/17-

8 [Terminal Layout (EURO Terminal Block) ()] (Input) BL29SB-0F -11-V50 (Output) BL29PB-0F -11-V50 (red) : transmission line (+) (black) : transmission line (-) (green) : for, connected load drive (+) (white) : for, connected load drive (-) on the transmission line connecting cable side and on the block are internally connected. on the transmission line connecting cable side and on the block are internally connected. And s with the same names are internally connected. to on the block can be used as a sensor power or power for output devices. (2 points, 1 common) The total passing current of -: maximum 0.A Terminal blocks 0 to 7 are s that connect input devices such as sensors, switches, LEDs and solenoid valves. (Input/output mixed) BL29XB-0F -11-V50 (red) : transmission line (+) (black) : transmission line (-) (green) : for, connected load drive (+) (white) : for, connected load drive (-) IN0 IN1 IN2 IN on the transmission line connecting cable side and on the block are internally connected. on the transmission line connecting cable side and on the block are internally connected. And s with the same names are internally connected. to on the block can be used as a sensor power or power for output devices. (2 points, 1 common) The total passing current of -: maximum 0.A Terminal blocks IN0 to 3 are s that connect input devices such as sensors and switches. Terminal blocks 0 to 3 are s that connect output devices such as LEDs and solenoid valves. IN0 IN1 IN2 IN Input Input output output -BL29*B0*F****V50 /17-

9 [Input/Output Circuit Configuration and Electrical Properties] (insulated) input BL29SB-0F- -V50 BL29XB-0F- -V50 (Input side) <Circuit conditions> Rated input voltage : DC Maximum switching current : 3.5mA ON current : 2.2mA or more OFF current : 1mA or less ON voltage : (-IN) 1V or more OFF voltage : (-IN) V or less (Green) (Red) (black) Internal circuit.k IN Switch, sensor, etc. (2-wire type) (White) (Green) In the case of connecting with a load (input/output port, etc.) controlled by a different from the power supply used with AnyWireASLINK, make sure to use a (insulated). Otherwise a malfunction may occur. [Ex.] Use with the common value set at. (Red) (black) (White) Internal circuit.k (insulated) ASLINK (AnyWire series ) IN Control circuit Load by external type (insulated) output BL29PB-0F- -V50 BL29XB-0F- -V50 (Output side) <Circuit conditions> Withstand voltage : 3 DC Maximum ON current : 100mA (Green) (Red) Internal circuit Load In the case of an inductive load, mount a surge killer. If the power is turned on with the circuit between and shorted, passive elements will be damaged. (black) (White) In the case of connecting with a load (input/output port, etc.) controlled by a different from the power supply used with AnyWireASLINK, make sure to use a (insulated). Otherwise a malfunction may occur. [Ex.] Use with the common value set at. (Green) (Red) (black) (White) Internal circuit (insulated) ASLINK (AnyWire series ) IN Control circuit Load by external type -BL29*B0*F****V50 9/17-

10 [Input/Output Circuit Configuration and Electrical Properties] (insulated) input BL29SB-0FS- -V50 BL29XB-0FS- -V50 (Input side) <Circuit conditions> (Green) Rated input voltage : DC Maximum switching current : 3.5mA ON current : 2.2mA or more OFF current : 1mA or less ON voltage : (IN-) 1V or more OFF voltage : (IN-) V or less (Red) Internal circuit.k IN Switch, sensor, etc. (2-wire type) (black) (White) (Green) In the case of connecting with a load (input/output port, etc.) controlled by a different from the power supply used with AnyWireASLINK, make sure to use a (insulated). Otherwise a malfunction may occur. [Ex.] Use with the common value set at. (Red) (black) Internal circuit.k (White) (insulated) ASLINK (AnyWire series ) IN Control circuit Load by external type (insulated) output BL29PB-0FS- -V50 BL29XB-0FS- -V50 (Output side) <Circuit conditions> (Green) Withstand voltage : 3 DC Maximum ON current : 100mA (Red) (black) (White) Internal circuit Load In the case of an inductive load, mount a surge killer. If the power is turned on with the circuit between and shorted, passive elements will be damaged. In the case of connecting with a load (input/output port, etc.) controlled by a different from the power supply used with AnyWireASLINK, make sure to use a (insulated). Otherwise a malfunction may occur. [Ex.] Use with the common value set at. (Green) (Red) (black) (White) Internal circuit (insulated) ASLINK (AnyWire series ) IN Control circuit Load by external type -BL29*B0*F****V50 10/17-

11 [Address Number Setting] 1Address number writing - The address number to be set to the is for correspondence to the input/output memory map of the controller. The address number represents an assignment position for AnyWire transmission frames (0 to 254) and occupies points following the number (and is not a station number). - The address number can be set by one point. - Use a dedicated address writer ARW-04 (Ver.04 to 1.01 or higher) or ARW-03 (Ver or higher) to write the address to be set in the. Refer to the User s Manual separately to learn how to operate the address writers ARW-04 (Ver.04 to 1.01 or higher) and ARW-03 (Ver.2.10 or higher). Connect the to the AnyWireASLINK master unit. Set address numbers with an address writer with the transmission signal (, ) and power ( / ) supplied. Setting image when setting with ARW-04 (Ver or higher), ARW-03 (Ver2.10 or higher) Direct the address writer toward the setting port (Fig. 1) of the body. Fig. 1 Setting port BL29SB-0F BL29XB-0F BL29PB-0F (Input side) (Output side) * Make sure to use a DC stabilized for the to be connected. Transmission signal AnyWireASLINK master DC* Red: Black: Example of BL29 B-0F-V50 BL29SB-0FS BL29XB-0FS (Input side) (Output side) BL29PB-0FS Avoid a short-circuit of the above lines during supply of power. A malfunction may result. The factory setting of the is 255, which means no setting. In this state, the cannot perform an input/output operation. An address auto-recognition (refer to the Manual of the master unit) cannot register the unit ID. Upon use, make sure to set the address numbers within the range of 0 to Set address numbers so that the area occupied by the does not exceed the transmission points of the master unit. Address numbers settable with BL29 B-0F -V50 : 0 to 24 Address numbers settable with BL29XB-0F -V50 : 0 to 252 2Settings reading Refer to the User s Manual separately to learn how to operate the address writers ARW-04 (Ver or higher) and ARW-03 (Ver.2.10 or higher). [Connection example] Master unit FK LP4-WR-10P Example of BL29 B-0F-V Link connector pin layout Pin No. Description Line color Black Red White Green LP connector (link connector) is a female and male integrated connector. Connection and branching are easily carried out by simply coupling the same type of connectors. LP4-WW-10P pressure welding To transmission line connector [Transmission line color] : Red : Black : Green : White Directly connect to a trunk line or branch line of 0.75mm 2 or 1.25mm 2 without extending the transmission line of the unit. -BL29*B0*F****V50 11/17-

12 [Indication Function] Example of BL29 B-0F -V50 Normal state: LINK flashing, ALM off, I/O ON on/off off LED indication LED symbol LINK (Green) ALM (Red) LINK ALM Indication status On Flashing Off On Flashing Off Alternate flashing LINK ALM Detailed states Transmission error Receiving transmission signal No transmission signal (including disconnection or reverse connection of, ) I/O voltage reduction Transmission signal level reduced Normal Master unit detecting the unit ID (address) redundant or not set LINK ALM I/O 0 I/O 1 I/O 2 I/O 3 I/O 4 I/O 5 I/O I/O 7 I/O (Orange) On Off Input ON Input OFF For information on narrowing down the cause of a trouble occurrence, see the following section Troubleshooting. In case of an abnormal indication status, narrow down the cause and remove the trouble based on the on/flashing status and the left table. The indication status will be restored automatically after the trouble is removed. [Troubleshooting] <LINK not flashing> Check items Check the connection status of the slave unit. Check the connection status of the master unit. Measures Disconnect and reconnect the slave unit. Check if the LINK LED of the master unit flashes and take the following measures. 1) If the LINK of the master unit flashes and the LINK of the slave unit is on, the master unit may be damaged. Please contact our helpdesk. 2) If the LINK of the master unit flashes and the LINK of the slave unit is off, the master unit may not be powered ( DC), the transmission line (, ) may be partially disconnected, or the slave unit may be damaged. Check if the master unit is powered and, if necessary, please contact our helpdesk. 3) If the LINK of the master unit does not flash, check if the master unit is powered. Other system errors may also occur. Refer to the User s Manual of the master unit. <ALM on> Check items Measures Check the I/O side connection of the slave unit. <ALM flashing> Check items Check the voltage of the external ( DC) of the master unit. Please adjust the voltage of the external power source to within the rated value of 21.V to 27.V. Also, with the wiring for s, please ensure that transmission lines are not touching or misfired. Measures Adjust the voltage of the external of the master unit to lie within the range from 21. to 27.V (recommended voltage is 2.4V). Check the total line length. Review the total line length and the size of the transmission line so as not to connect a load exceeding a supply current limit on the transmission line and, if necessary, adjust the connected load (e.g. the supply current on the transmission line is 2A if the size is 1.25mm 2 and the total length is 50m or less). <LINK and ALM flashing alternately> Check items Measures Check the address of the slave unit. The address of the slave unit is not set (255) or address redundancy occurs. Take the following measures. 1) Change the address within the range from 0 to ) Check if there is another slave unit undergoing the same flashing and, if necessary, reset the address so as not to be redundant. -BL29*B0*F****V50 12/17-

13 [Specifications] General Specifications Ambient temperature use Ambient humidity use Temperature/humidity storage Atmosphere Altitude use *1 Pollution level *2 Noise resistance %RH No condensation No corrosive gas m 2 or less 120p-p (pulse width 1μs) Transmission Specifications Power supply voltage use Transmission method Synchronization method Transmission procedure Connection mode Number of connection points Number of connection points DC +15% to -10% (21. to 27.V DC) with a ripple of 0.5Vp-p or less DC superimposed total frame/cyclic method Frame/bit synchronization method Dedicated protocol Bus type (Multi-drop method, T-branch method, tree method) 512 max. (IN: 25, : 25) Up to 12 units *1 Do not use or store AnyWireASLINK equipment under an environment pressurized higher than the atmospheric pressure at an altitude of 0m. Otherwise, a malfunction may occur. *2 This is an index that shows the occurrence level of conductive substances in the environment where the equipment is used. In the case of pollution level 2, only non-conductive pollution occurs. However, this is an environment where temporary conductivity can occur by accidental condensation. Individual Specifications Type I/O point Input Output Method consumption current(ma) Transmission side I/O side* 3 Mass Monitoring function Response time* 4 BL29SB-0F-V50 40 BL29PB-0F-V50 BL29XB-0F-V input 20 output 90g BL29SB-0F-3-V50 40 BL29PB-0F-3-V50 BL29XB-0F-3-V input 20 output 5g BL29SB-0F-11-V50 40 BL29PB-0F-11-V50 BL29XB-0F-11-V50 BL29SB-0FS-V input 20 output 40 5g Slave unit voltage reduction I/O voltage reduction Up to 1ms BL29PB-0FS-V50 BL29XB-0FS-V input 2 output 90g BL29SB-0FS-3-V50 40 BL29PB-0FS-3-V50 BL29XB-0FS-3-V input 2 output 5g BL29SB-0FS-11-V50 40 BL29PB-0FS-11-V50 BL29XB-0FS-11-V input 2 output 5g * 3 *The value described in the input is the value when all points between IN are shorted. When connecting a 3-wire sensor, add the total consumption current of the sensor. *The value described in the input/output mixed is: Input: the value when all points between IN- are shorted. When connecting a 3-wire sensor, add the total consumption current of the sensor. Output: the value when all points are ON. Add the total connected load consumption current. *The value described in the output is the value when all points are ON. Add the total connected load consumption current. * 4 *Apart from the transmission delay time (2 cycle time), this is internal processing time required for the to recognize signal changes. -BL29*B0*F****V50 13/17-

14 [Outside dimensions] BL29 B-0F -V50 Unit: mm (49)* Ø Ø4..5 (0.9).2 (0.9) 32.2 * Terminal block cover opening status Black = Red = White = Green = Ø1.4 UL style wires No.23AWG (Gray) Ø Supports M3, 7.2mm pitch, width mm, crimping s -BL29*B0*F****V50 14/17-

15 [Outside dimensions] BL29 B-0F -3-V50 Unit: mm Ø Ø4. (1.47) 2.0 (1.47) Black = Red = White = Green = Ø1.4 UL style wires No.23AWG (Gray) Ø * The figure shows an example of layout for -point output. Spring type Euro block Core diameter of connecting electric wire: 0.0 to 2.5mm 2 Length of stripped electric wire: 5 to mm When connecting two wires to one, bind the wires with a twin ferrule (crimp clamp) and insert it in the. -BL29*B0*F****V50 15/17-

16 [Outside dimensions] BL29 B-0F -11-V50 Unit: mm Ø3.5 Ø4. (0.1) 4.07 (0.75) Black = Red = White = Green = Ø1.4 UL style wires No.23AWG (Gray) Ø * The figure shows an example of layout for -point output. Length of stripped wire : mm Connecting wire: twisted wire : 0.14 to 1.5mm 2 When crimping bar with sleeve : 1mm 2 When crimping 2-wire bar with sleeve : 0.5mm 2 -BL29*B0*F****V50 1/17-

17 [Outside dimensions] A-10 (installation dedicated DIN rail adapter) dimensions Unit: mm (500) Ø3.5 (Mounting screw hole) UL style wires No.23AWG (Gray) Ø Black = Red = White = Green = [Address] Anywire Corporation Headquarters :1 Babazusho, Nagaokakyo-shi, Kyoto JAPAN Contact :Contact by mail :Contact by website info_e@anywire.jp Printed in Japan 2015,201,2017 UMA-1130F-EN -BL29*B0*F****V50 17/17-

AnyWire System Product Guide. AnyWire Picking Terminal series/ Transparent Type A027PB-T02G-P/ light-emitting unit A027XB-T02G-C/ light-receiving unit

AnyWire System Product Guide. AnyWire Picking Terminal series/ Transparent Type A027PB-T02G-P/ light-emitting unit A027XB-T02G-C/ light-receiving unit R AnyWire System Product Guide AnyWire Picking Terminal series/ Transparent Type A07PB-T0G-P/ light-emitting unit A07XB-T0G-C/ light-receiving unit Eject check input (Orange) AnyWire is the registered

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

CUS150M1 Instruction Manual

CUS150M1 Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all cautions and warnings before using this product. Incorrect usage could

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

PMDX-170 Slotted Optical Sensor

PMDX-170 Slotted Optical Sensor PMDX-170 Slotted Optical Sensor User s Manual Date: 20 May 2009 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton, VA 22079-2366 USA FAX: +1 (703) 372-2977 PMDX-170_Manual_10.doc

More information

ELV12 Series. Instruction Manual

ELV12 Series. Instruction Manual Instruction Manual TDK-Lambda BEFORE USING POWER SUPPLY UNIT Be sure to read this instruction manual thoroughly before using this product. Pay attention to all warnings and cautions before using the unit.

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

DC I/O Conversion Module FA-TB32XY

DC I/O Conversion Module FA-TB32XY DC I/O Conversion Module FA-TB32XY User's Manual Thank you for purchasing FA Goods product. Before using, please read this User s Manual and the relevant manuals carefully to ensure correct use. SAFETY

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Complementary Analogue input resolution Permissible continuous overload Input impedance LSB value Conversion time Sampling duration Main Range of product

More information

SiO Controller. SiO Controller. SiO-C Ver onwards SiO2/SiO2PNP Ver onwards SiO3 Ver onwards INSTRUCTION MANUAL. Version 3.

SiO Controller. SiO Controller. SiO-C Ver onwards SiO2/SiO2PNP Ver onwards SiO3 Ver onwards INSTRUCTION MANUAL. Version 3. SiO Controller SiO-C Ver. 2.00 onwards SiO2/SiO2PNP Ver. 1.00 onwards SiO3 Ver. 1.00 onwards INSTRUCTION MANUAL Version 3.2 WARRANTY RANGE Warranty Period 1 year period after date of purchase 1. This product

More information

PRO-1250D CT MID DIN rail three phase four wire energy meter.

PRO-1250D CT MID DIN rail three phase four wire energy meter. PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

One step ahead in performance and mounting ease

One step ahead in performance and mounting ease 95 Micro Photoelectric Amplifier Built-in PM-5 SERIES PM-45 SERIES PM-5 SERIES General terms and conditions... F- guide... P.9~ Related Information Glossary of terms / General precautions...p.1549~ / P.155~

More information

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8

More information

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable 44 Connector Built-in Micro Photoelectric SERIES Related Information General terms and conditions... F-1 Glossary of terms... P.1~ selection guide... P.441~ General precautions... P.140 Amplifier Built-in

More information

DC I/O Conversion Module

DC I/O Conversion Module DC I/O Conversion Module,FA-TB32XYH User's Manual Thank you for purchasing FA Goods product. Before using, please read this User s Manual and the relevant manuals carefully to ensure correct use. SAFETY

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information Chemical-resistant Proximity Sensor E2KQ-X CSM_E2KQ-X_DS_E_4_3 Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster Excellent resistance against chemicals and oil with fluororesincoated case.

More information

MT8050iE series. Installation Instruction (1) (2)

MT8050iE series. Installation Instruction (1) (2) MT8050iE series 3 Installation Instructions Installation Instruction Secure the operator panel in position, using all the fastening holes and the provided brackets and screws: (A) 1 Installation and Startup

More information

5504 Thermocouple Analog Input Module

5504 Thermocouple Analog Input Module 550 Thermocouple Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

Installation manual for for Schleifenbauer DPM3

Installation manual for for Schleifenbauer DPM3 Installation manual for for Schleifenbauer DPM3 Installatie handleiding voor Schleifenbauer DPM3 Installationsanleitung für Schleifenbauer DPM3 Guide d installation du Schleifenbauer DPM3 Installation

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O

More information

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide

More information

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm Digital Amplifier Ultrasonic Sensor CSM DS_E_1_1 A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Compact with a Broad Selection of Side-view Heads Slim with analog outputs

More information

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input Product datasheet Characteristics TM241C24R Complementary Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Discrete input logic Discrete input voltage Discrete

More information

TM3DI16G module TM3-16 inputs spring

TM3DI16G module TM3-16 inputs spring Characteristics module TM3-16 inputs spring Main Range of product Product or component type Range compatibility Modicon TM3 Discrete input module Modicon M221 Modicon M241 Modicon M251 Discrete input number

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

H704-42(H)(E), H704-42/1(H)(E)

H704-42(H)(E), H704-42/1(H)(E) POWER MONITORING INSTALLATION GUIDE H704-42(H)(E), H704-42/1(H)(E) Branch Current Monitor DANGER NOTICE Installer's Specifications General: Operating Temp. Range 0 to 60 C (32 to 140 F) (

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 CK3W Power Supply Unit CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2 Supplies power to the CK3M Controller CK3W-PD048 Features 24 VDC input The power supply status indicator shows operating status 1 Ordering

More information

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM

Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM Mini-DVI-WP Series WALL PLATE MINIATURE MULTIMODE FIBER OPTIC DVI TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent. No liability

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1D V21.212 Version 1.1 Note: the picture on the frontpage is a meter from the series of this meter, it might not be exactly the same

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE PC-HELPER PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE User s Manual CONTEC CO.,LTD. Check Your Package Thank you for purchasing

More information

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER

USER'S GUIDE FX-485ADP COMMUNICATION ADAPTER FX0N-485ADP COMMUNICATION ADAPTER FX- COMMUNICATION ADAPTER FX0N- COMMUNICATION ADAPTER USER'S GUIDE JY992D53201C This manual contains text, diagrams and explanations which will guide the reader in the correct installation and operation

More information

PRO-75 SERIES. User manual

PRO-75 SERIES. User manual PRO-75 SERIES DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation

More information

Description. Green. Red. Orange

Description. Green. Red. Orange GP3000 Series DIO Interface Installation Guide Caution Be sure to read the Warning/Caution Information on the attached sheet before using the product. CAUTION This manual describes the part names and general

More information

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module) SDM120 SERIES Single phase two wire DIN rail energy meter (One module) User manual ------------ 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Dimension

More information

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs 1 Sensor Block for SC Quick connection of 16 sensors Set of 16 inputs directly hooked up to PLC Up to 16 sensors can be connected on one main block followed by three extension blocks (or one snapconnector

More information

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box Product datasheet Characteristics TM7BDI16B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 16 Input/output number of

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-90AW User s Guide CONTEC CO., LTD.

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-90AW User s Guide CONTEC CO., LTD. CONPROSYS 24VDC AC-DC Converter CPS-PWD-90AW24-01 User s Guide CONTEC CO., LTD. Check Your Package Thank you for purchasing the CONTEC product. This product consists of the items listed below. Check, with

More information

NJ-Series Power Supply Unit NJ-PA/PD

NJ-Series Power Supply Unit NJ-PA/PD NJ-Series Power Supply Unit CSM_NJ-PA_PD_DS_E_1_2 Powerful power supply unit to supply stable power to the NJ-series controller. Stable power supply is available from the NJ-series CPU Unit to each I/O

More information

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box Product datasheet Characteristics TM7BDM8B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 8 Input/output number of splitter

More information

Analog Input Installation Manual

Analog Input Installation Manual Analog Input Installation Manual August 2011 Part Number: 144-23917 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems

More information

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

VS-P Series. TDK-Lambda INSTRUCTION MANUAL VS5P /75P /1P/ 15P Instruction Manual BEFORE USING THE POWER SUPPLY UNIT Pay attention to all warnings and cautions before using the unit. Incorrect usage could lead to an electrical shock, damage to the

More information

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E PROGRAMMABLE CONTROLLER Technical Manual ARCT1F321E-2 2008.11 Safety Precautions Observe the following notices to ensure personal safety or to prevent accidents. To ensure that you use this product correctly,

More information

PRODUCT SPECIFICATION. PC Board Relays. Series.

PRODUCT SPECIFICATION. PC Board Relays. Series. PRODUCT SPECIFICATION PC Board Relays 26 Series www.wernerelektrik.com Technical Data... Specifications...2 Model Number Structure - Relays...3 Model Number Selection...4 Dimensions... 5-6 Accessories...7

More information

INJ-24A Series Quick Installation Guide

INJ-24A Series Quick Installation Guide INJ-24A Series Quick Installation Guide Moxa High-Power PoE+ Injector Edition 4.1, August 2017 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL

More information

XTM1250SA DIN rail three phase four wire LCD display energy meter

XTM1250SA DIN rail three phase four wire LCD display energy meter XTM1250SA DIN rail three phase four wire LCD display energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Intrinsic errors 1.6 Description 1.7 Dimensions 1.8

More information

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation

More information

Output Terminal Module

Output Terminal Module Output Terminal Module FA-TH16YRA11/11S/20/20S/20SL/21/21S,FA-TH16YRAC20S, FA-TH16YRAB20SL,FA-TH16YSR11S/20S/21S, FA-TH16YTL11S/21S,FA-TH16YTH11S,FA-TH16YTR20S, FA-TH16Y2TR20,FA-THE16YTH11S,FA-THE16YTR20S

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for

More information

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor Aluminum-detecting Proximity Sensor EEY CSM_EEY_DS_E_5_1 A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Non-ferrous metals, such as aluminum and brass, are detected.

More information

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines! 1215 PHOTO PHOTO SAFETY USE SERIES Related Information General terms and conditions... F- General precautions... P.1595 guide... P.1155~ MEASUREMENT panasonic.net/id/pidsx/global Continuously check invisible

More information

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1 Common to all H3CR Note: The undermentioned is common for all H3CR models. Basic Setting Setting of Selectors The s can be turned clockwise and counterclockwise to select the desired time unit, time range,

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD.

USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. USB to RS232 Converter USB-013 (Rev3) User s Manual Ver. 1.2 HuMANDATA LTD. Table of Contents Precautions... 1 Revision History... 2 Introduction... 2 1. Overview... 3 2. Power Supply... 3 3. Specifications...

More information

Terminal block 2 A 5 X 3. Specification

Terminal block 2 A 5 X 3. Specification D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables

More information

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TM3 module TM3-2 temperature inputs and 1 analog output Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number

More information

COMMUNICATION CONVERTER FOR PROFIBUS

COMMUNICATION CONVERTER FOR PROFIBUS INSTRUCTION MANUAL COMMUNICATION CONVERTER FOR PROFIBUS IFP-100 No.IFP11E3 2012.01 Preface Thank you for purchasing our IFP-100, Communication Converter for PROFIBUS. This manual contains instructions

More information

Making Hazardous Operations Safe and Productive

Making Hazardous Operations Safe and Productive NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series

More information

TM241CE40R controller M IO relay Ethernet

TM241CE40R controller M IO relay Ethernet Product data sheet Characteristics TM241CE40R controller M241 40 IO relay Ethernet Complementary Main Discrete I/O number 40 Discrete input logic Discrete input voltage Discrete input voltage type Voltage

More information

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21 Solid-state timer CSM DS_E_3_2 Ultra-slim Timer for G2R Relay Socket Pin configuration compatible with G2R Relay and mounts to the P2R/P2RF Socket. Standard multiple time ranges and multiple operating

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-30AW User s Guide CONTEC CO., LTD.

CONPROSYS. 24VDC AC-DC Converter CPS-PWD-30AW User s Guide CONTEC CO., LTD. CONPROSYS 24VDC AC-DC Converter CPS-PWD-30AW24-01 User s Guide CONTEC CO., LTD. Check Your Package Thank you for purchasing the CONTEC product. This product consists of the items listed below. Check, with

More information

RMCN22BD Analog Converter ma - for Zelio Analog

RMCN22BD Analog Converter ma - for Zelio Analog Characteristics Analog Converter - 4..20 ma - for Zelio Analog Main Commercial Status Range of product Product or component type Analogue input type Analogue output type Commercialised Zelio Analog Voltage/Current

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global

Remote I/O Unit with Connectors for Light Curtain CC-Link Safety System. panasonic.net/id/pidsx/global 715 LIGHT CURTAINS / USE Remote I/O Unit with Connectors for Light Curtain CC-Link System General terms and conditions... F-7 Related Information... P.703~ SF4B... P.565~ General precautions... P.1501

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information

Optimum sensing capability for LCD manufacturing

Optimum sensing capability for LCD manufacturing SENSORS FOR Glass Substrate Detection Sensor Amplifier-separated FX-301-F FT-F9 FD-F7 EX-F70/F60 HD-T1 M FD-L3 Reliable detection of glass substrates Its unique optical system enables detection of transparent

More information

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method Controller EC07 EC63 Compatible actuators: ERL ESD Features Compact, light weight and thin (Body width 35mm) Can be set without manual Perfect installation compatibility with actuator PC software available

More information

PRO1250D CT MODBUS MID Three phase four wire energy meter.

PRO1250D CT MODBUS MID Three phase four wire energy meter. PRO1250D CT MODBUS MID Three phase four wire energy meter. User manual Version 1.11 1 Safety instructions...3 2 Foreword...4 3 MID certificate...5 4 CE certificate...6 5 Performance criteria...8 6 Specifications...8

More information

QAL50 Series Analog Line Sensor

QAL50 Series Analog Line Sensor Datasheet Compact, self-contained analog- and discrete-output edge-guiding sensor Compact, self-contained design Analyzes and compares target object position or width, relative to a reflective strip Fast

More information

V E1B Snap-in I/O Module

V E1B Snap-in I/O Module V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital

More information

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual

CONTROL MICROSYSTEMS Analog Output Module. Hardware Manual 5304 Analog Output Module Hardware Manual CONTROL MICROSYSTEMS SCADA products... for the distance 48 Steacie Drive Telephone: 613-591-1943 Kanata, Ontario Facsimile: 613-591-1022 K2K 2A9 Technical Support:

More information

Three-phase Phase-sequence Phase-loss Relay

Three-phase Phase-sequence Phase-loss Relay Three-phase Phase-sequence Phase-loss Relay K8AB-PM Ideal for monitoring 3-phase power supplies for industrial facilities and equipment. Monitor overvoltages, undervoltages, phase sequence, and phase loss

More information

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS PRODUCT DESCRIPTION ARTICLE CODES INTENDED AREA OF USE TECHNICAL DATA STANDARDS OPERATIONAL DIAGRAMS WIRING AND CONNECTIONS

More information

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration

NX-series SSI Input Unit. Read position information from encoders with Synchronous Serial Interface (SSI). Features. System Configuration NX-series SSI Input Unit CSM DS_E_1_1 Read position information from encoders with Synchronous Serial Interface (SSI). Process SSI encoder input data using the MC Function Modules of the NJ-series Machine

More information

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2. Product datasheet Characteristics TM241CEC24T Main Range of product Product or component type [Us] rated supply voltage Discrete input number Discrete output type Discrete output number Discrete output

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display. NEW product No, NPPDF 6-01E Large digital sensor 31series SEU-31 Easily viewable LCD dual displays. igh level visibility with 3-color display 2-Color indications depending on output. Main display : Pressure

More information