INTELLIGENT TRANSFER SWITCH

Size: px
Start display at page:

Download "INTELLIGENT TRANSFER SWITCH"

Transcription

1 IT-SWITCH 6A & 0A IT-SWITCH (models B & E) - 6A & 0A ITELLIGET TRASFER SWITCH 6A AD 0A USER'S GUIDE UPS/TA GB/ITS6.E 8/06/007

2 UPS/TA GB/ITS6.E page /4 FOREWORD We thank you for the trust you have in SOCOMEC UPS IT-SWITCH (models S, B and E). Our equipment complies with: - Electromagnetic compatibility directives as per standards E and E 5008-, - Low Voltage directives. SAFETY REQUIREMETS Conditions: Do read carefully these operation instructions before proceeding to the IT-SWITCH commissioning. For an optimal use, it is recommended to: - maintain the ambient temperature between 0 C and 35 C, - maintain the humidity rate below 90% (condensation-free). Precautions the user should take: WARIG: It is absolutely necessary to earth the IT-SWITCH before connecting any upstream and downstream supplies. Hazard remain present even if the IT-SWITCH output has been switched off ; supply voltage of sources and is indeed still present. Do not remove the cover without completely disconnecting the IT-SWITCH from the input supplies and. Do follow scrupulously the procedures when switching the IT-SWITCH on or off. Whatever the repairs, they must be exclusively executed by authorised and skilled staff. This equipment meets the requirements of the European directives applied to this product. Hence it is labelled as follows: This equipment is designed to a restricted distribution in compliance with the conditions defined by the standard E As a consequence, restrictions to the installation or complementary steps may be needed to prevent potential electromagnetic interference.

3 UPS/TA GB/ITS6.E page Certificate of Warranty This SOCOMEC UPS IT SWITCH is guaranteed against any defect in construction or operation arising from faulty design or materials for a period of months, valid from the date of purchase. The warranty certificate must OT be sent to the manufacturer but should be kept in a safe place together with proof of purchase, as these will be required should the product need to be repaired or replaced under the terms of the warranty. The period of validity of the warranty is calculated from the date of purchase by the end user from an authorised dealer (the date on the purchase document is sufficient for this purpose). The warranty is of the 'carry-in' kind: SOCOMEC UPS will provide parts and labour free of charge for all repair work carried out, but the customer is responsible for the cost and risk of transport to and from SOCOMEC UPS. For these stipulations to be valid, the Purchaser must comply with the following: - the product must only be returned in its original packing. Any damage caused to the product during transport, where the original packing has not been used, is not covered by the terms of this warranty. - The product must be accompanied by proof of purchase (i.e. invoice, receipt) stating the date of purchase and clearly identifying the product (i.e. bearing the model and serial number). The repair return authorisation number is given by the service centre over the phone after they have received a detailed description of the fault. Failure to provide one of these means that the warranty is no longer valid. - Should the customer not be able to provide proof of purchase, the serial number and the date of manufacture will be used to calculate the warranty period. This may mean the warranty period is shorter than it would otherwise be. - The warranty does not cover damage due to misuse (use out of tolerances: power supply, lightening, humidity, temperature, poor ventilation, etc.), tampering or any other kind of non-authorised intervention. - During the warranty period, SOCOMEC UPS liability is limited to the obligations as defined herein (repair or replacement).

4 UPS/TA GB/ITS6.E page 3 COTETS. PURPOSE OF THE IT-SWITCH...5. IT-SWITCH ARRAGEMET SUMMARY TABLE OF THE VARIOUS FUCTIOS AVAILABLE O MODELS S, B AD E FIED 9" RACK VERSIO (MODELS S OR B) HOT-SWAP 9" RACK VERSIO (MODEL E) MAI FEATURES COECTIO MEAS O THE REAR FACE: PRECAUTIOS UPO RECEIPT GEERAL RECOMMEDATIOS FOR ISTALLATIO ASSEMBLIG MODELS "S", "B" OR "E" I A STADARD 9" CABIET SAFETY REAR PAEL OF THE FIED IT-SWITCH (MODELS S OR B) REAR PAEL OF THE HOT-SWAP IT-SWITCH (MODEL E) REAR PAEL EQUIPPED WITH SOCKETS 6 A OF IEC30 TYPE REAR VIEW WITH TERMIALS (IT SWITCH 6A & 0A) DETAILS OF COECTIO TERMIAL ETERAL COMMUICATIO LIKS REMOTE TRASFER THROUGH POTETIAL-FREE COTACTS REMOTE TRASFER THROUGH SERIAL LIK.... OPERATIG PRICIPLE...4. COTROL PAEL DESCRIPTIO OF STATES AD ALARMS KEY COTROLS OPERATIO EPLAATIOS COMMISSIOIG - OPERATIO PRELIMIARY CHECKS SAFETY - REMIDERS PRELIMIARY CODITIOS LOAD SUPPLY CHAGIG THE SOURCE PRIORITY (MODELS S, B AD E) LOAD DISCOECTIO TRASFER TO MAUAL BYPASS (IT-SWITCH MODEL E) SEAMLESS REPLACEMET OF THE ELECTROIC RACK (IT-SWITCH MODEL E) DESCRIPTIO OF THE VARIOUS STATES TRASFER IMPOSSIBLE IMMIET SHUTDOW GEERAL ALARM DIFFICULTIES DURIG COMMISSIOIG MAITEACE TROUBLE SHOOTIG...3

5 UPS/TA GB/ITS6.E page 4 ABBREVIATIOS IT-SWITCH SW : Intelligent Transfer Switch : Switch MODBUS/JBUS : Industrial communication protocol, APRIL registered brand ote: Packaging Data labels. Fixed 9'' standard rack version (model S) The reference marked on the packaging and on the data labels: IT-SWITCH 6A MS.. Fixed 9'' HA rack version (model B) The reference marked on the packaging and on the data labels: IT-SWITCH 6A MB. 3. Hot Swap 9'' rack version (model E) The marking reference on the packaging is: - IT-SWITCH 6A MET or IT-SWITCH 0A MET if the system is fitted with terminal connections, - IT-SWITCH 6A MES if the system is fitted with sockets 6 A of IEC30 type. The references on the data labels are as follows: - IT-SWITCH 6A ET + serial number if the chassis is fitted with terminal connections, - IT-SWITCH 6A ES + serial number if the chassis is fitted sockets 6A of IEC30 type, - IT-SWITCH 6A ME or IT-SWITCH 0A ME + serial number for the hot swap rack.

6 SECTIO GEERAL PRESETATIO UPS/TA GB/ITS6.E page 5. PURPOSE OF THE IT-SWITCH The IT-SWITCH provides a dual redundant supply to the load(s) from two synchronous and alternating sources. The IT-SWITCH senses voltage outages and ensures the load automatically transfers to the alternate source (seamless for the load). The IT-SWITCH improves the load power supply reliability. The load can quickly be transferred (either automatically or manually) from the so called "Preferred" source to the "alternate" source (and vice versa). ote: this document provides information in terms of safety, connection and using.. IT-SWITCH ARRAGEMET Three versions of IT-SWITCH are available: - fixed 9'' standard rack version (model S) - fixed 9'' HA rack version (model B) - hot-swap 9'' rack version (model E), with a manual bypass for replacing the live IT-SWITCH without interrupting the load power supply. Both versions can be mounted in standard 9'' cabinets... Summary table of the various functions available on models S, B and E Standard IT-SWITCH HA IT- SWITCH Hot swap HA IT-SWITCH FUCTIOS Model S Model B Model E - Type of transfer: manual without overlapping synchronous/asynchronous synchronous type only - Detection of short circuit on the output - Counter for successive transfers upon failure - Hot Swap unit - Manual by-pass - Serial link (JBUS) - Dry contacts - Selection of priority source - Event log - Socket for commissioning and servicing PC sources High Availability

7 UPS/TA GB/ITS6.E page 6.. Fixed 9" rack version (Models S or B) OVERVIEW Front: Rear: - Mimic panel - Access door for connecting the maintenance PC - handles connections through socket 6 A of IEC 30 type - see section 8 for: - source input - output to the loads (4 output sockets). Dimensions are mentioned in section 3. BASIC SCHEME SOURCE IPUTS SW SW TO THE LOADS

8 UPS/TA GB/ITS6.E page 7.3. Hot-swap 9" rack version (Model E) This version additionally comprises a chassis (9'' format) in which can be found the manual bypass switch. The chassis accommodates the IT-SWITCH rack that can be removed without disconnecting the load supply. Dimensions are mentioned in section 3. OVERVIEW A B A Hot-swap IT-SWITCH rack including on the front: - the mimic panel, - the access door to the manual bypass switch and to the connection socket for maintenance PC, - the handles for pulling out the rack B Chassis including the MAUAL BYPASS and rear connections. BASIC SCHEME IPUT SOURCES SW SW A B TO THE LOADS A Hot-swap IT-SWITCH rack with switching electronics. B Fixed 9'' chassis with the manual bypass.

9 UPS/TA GB/ITS6.E page 8 3. MAI FEATURES Electrical data and performance Supply Single phase Input voltages (source and source ) 0V-0V-30V-40V ± 0 % rms Rated frequency Hz ± 0 % Phase tolerance admitted between Source/Source for seamless transfer 5 Max gradient for frequency variation 0 Hz/sec Rated current 6A or 0A Peak factor 4 CURRET Model S Models Models E B and E (6A) (0A) Overloads, In h 3h h,5 In 0' 30' 0',5 In ' 6' ' In 0" ' 0" Ventilation atural Maxi ambient temperature 40 C Humidity < 90 % condensation-free Altitude 000 m Protection index IP Mechanical data Width Depth 3 Height Weight Fixed models S and B 6A 446 mm 300 mm 3 mm 8,5 kg Hot-swap model E 6A & 0A 449 mm 390 mm 33 mm 4 kg 3.. Connection means on the rear face: Connections are to be done on the rear panel of the IT-SWITCH. The fixed IT-SWITCH (models S or B) is fitted with sockets 6A of IEC 30-type (see 8). The hot-swap IT-SWITCH (model E) is fitted with either: - screw terminals (IT-SWITCH 6A and 0A) - sockets 6 A of IEC 30 type (IT-SWITCH 6A only). 484 mm with fixing squares 3 + 0mm including screws and + 40mm including handles (overall dimension: + 50 mm)

10 SECTIO ISTALLATIO - COECTIOS UPS/TA GB/ITS6.E page 9 4. PRECAUTIOS UPO RECEIPT Always inspect the packaging condition of the equipment upon receipt (in terms of damage, shocks, or enclosure deformation). If necessary, write down discrepancies on the delivery note. Carefully extract the IT-SWITCH from its packaging, knowing that the weight is not evenly shared within the case. 5. GEERAL RECOMMEDATIOS FOR ISTALLATIO The environment should: - be protected by humidity, - provide no obstacle to prevent air circulation, especially if the IT-SWITCH is located in a cabinet, - allow sufficient ventilation to ensure a constant operating temperature, - be dry, clean and dust free, - be free of flammable vapour or corrosive smoke. REMIDER : The ambient temperature recommended is between 0 and 35 C. 6. ASSEMBLIG MODELS "S", "B" OR "E" I A STADARD 9" CABIET The ensure proper assembling, the IT-SWITCH (models S, B or E) shall lie on the horizontal side fixing bars in the cabinet (see fig. marking A) or on the support brackets at the rear of the rack (see fig. ). Models S and B (fixed) is provided with assembling accessories ( braces marked E443) for fastening to the front frame of the standard 9" cabinet (see fig. 3). Model E (hot-swap) has a built-in fastening means on the chassis (see fig. 4). Figure Figure 3 A A Figure Figure 4

11 UPS/TA GB/ITS6.E page 0 7. SAFETY IMPORTAT It is recommended to carefully read this manual prior to source and load connections. This manual should be kept close to the IT-SWITCH for easy consultation if needed. CAUTIO For connections to terminals (IT-SWITCH model E): EARTHIG COECTIOS ARE TO BE MADE PRIOR TO SOURCE COECTIOS. IMPORTAT ELECTRICAL COECTIOS AS WELL AS CABLIG OPERATIOS SHOULD OLY BE MADE BY SKILLED AD SUITABLY TRAIED PERSOEL. 8. REAR PAEL OF THE FIED IT-SWITCH (models S or B) The rear panel comprises (see 9..): - input male sockets IEC30 6A, - 4 output female sockets IEC30 6A - hot-swap connectors with securing screws for external communication: - 3 for alarm transfers through potential-free contacts (use twisted cables), - 3 for remote transfers through serial link (use shielded twisted cables). IPUT SOURCE SHIELD COECTIO IPUT SOURCE LOAD OUTPUT 4 sockets available ETERAL COMMUICATIO Details about the connection of IEC sockets: IPUT SOURCE IPUT SOURCE LOAD OUTPUT EUTRAL PHASE PE: Electrical protective conducteur PHASE PE: Electrical protective conducteur EUTRAL

12 UPS/TA GB/ITS6.E page 9. REAR PAEL OF THE HOT-SWAP IT-SWITCH (MODEL E) The rear panels can either comprise sockets 6 A of IEC 30 type or terminals. ote: for the IT SWITCH 0A, connection is only by means of terminals. 9.. Rear panel equipped with sockets 6 A of IEC30 type The rear panel shows: - inputs male sockets IEC30 6A, - 4 output female sockets IEC30 6A, - hot-swap connectors with securing screws for external communication: - 3 for alarm transfers through potential-free contacts (use twisted pairs), - 3 for remote transfers through serial link (use shielded twisted cables). IPUT SOURCE SHIELD COECTIO IPUT SOURCE LOAD OUTPUT 4 sockets available ALARM TRASFER ETERAL COMMUICATIO Please refer to section 8 for connections. 9.. Rear view with terminals (IT SWITCH 6A & 0A) Loosen the 6 screws on the rear panel to connection area. REAR PAEL The connection area includes the terminals and the connectors.

13 UPS/TA GB/ITS6.E page COECTIO AREA 3 3 Connector to the chassis on the IT-SWITCH rack Manual Bypass switch Connection terminal to SOURCES and LOAD Alarm transfer External communication 9.3. Details of connection terminal SOURCE SOURCE LOAD = eutral = Phase 3 = PE 7 = eutral 8 = Phase 9 = PE 4 = eutral 5 = Phase 6 = PE 0. ETERAL COMMUICATIO LIKS 0.. Remote transfer through potential-free contacts Connector 3 is for remote transfer of the following states and alarms: STATUS and ALARMS Source O Source O Source preferred Transfer impossible General Alarm terminals -, closing contact terminals 3-4, closing contact terminals 5-6, closing contact terminals 7-8, closing contact terminals 9-0, contact closed upon failure OTE: breaking capacity of contacts: 0,5 A with 5VAC. Use twisted wires. These contacts are set to close by default. 0.. Remote transfer through serial link Connector 3 enables the connection through the RS485 (or RS4) type serial link under the MODBUS/JBUS protocol. For address assignment, please refer to manual UPS/TA GB/MTCJBUS.

14 UPS/TA GB/ITS6.E page 3 RS485 Link On 3, strap terminals and if the IT-SWITCH is line end. terminal : T+ / R+ terminal 3: T- /R- terminal 7: 0V Isolated RS4 Link On 3, strap terminals and ; as well as 5 and 6 if the IT-SWITCH is line end. terminal : T+ terminal 3: T- terminal 4: R+ terminal 5: R- terminal 7: 0V Isolated OTE: Use shielded and twisted wires For communication with a building management system or TOP VISIO supervision system, use serial link RS485.

15 UPS/TA GB/ITS6.E page 4 SECTIO 3 OPERATIO. OPERATIG PRICIPLE In normal operating conditions, the IT-SWITCH supplies the load from the preferred source. The latter can be selected by the operator, depending on the operating requirements of the site. Two different transfer modes can be selected: - the manual mode by pressing the push button on the control panel: " SOURCE " to supply the load from source " SOURCE " to supply the load from source - or the automatic mode, upon source failure. In such a case, the IT-SWITCH: - senses a failure on the preferred source and ensures the automatic load transfer to the alternate source, - senses a failure on the alternate source and ensures the automatic seamless load transfer to the priority source, following a manual transfer to the alternate source. OTE: the preferred source (source or source ) is selected from the control panel (see.) of from the TOP VISIO supervision workstation.

16 UPS/TA GB/ITS6.E page 5. COTROL PAEL It comprises a mimic panel that represents the IT-SWITCH and the flow of energy that passes through it. Three keys are for operating the system... Description of states and alarms GREE led SOURCE PREFERRED GREE led SOURCE PREFERRED GREE led GREE led IPUT VOLTAGE PRESET O SOURCE or SOURCE SOURCE or SOURCE O ORAGE led TRASFER BLOCKED (see.3.3.) ORAGE led TRASFER IMPOSSIBLE (see.3..) RED led Slow blinking: short-circuit current detected Rapid blinking: IMMIET SHUTDOW (see 4..) Fixed light on: MAUAL BYPASS switch in position or ORAGE led MAUAL BYPASS of source or source O (IT-SWITCH model E) ot used (IT-SWITCH models S and B) ORAGE led GEERAL ALARM

17 UPS/TA GB/ITS6.E page 6.. Key controls Key makes it possible to close static switch SW. Key makes it possible to close static switch SW. Key (alarm reset) shows three functions: - light pressing for resetting the audible beep, - long pressing (5 seconds minimum) for selecting the preferred source. - pressing together with key or (depending on the source supplying energy) causes the load disconnection (see.3.4)..3. OPERATIO EPLAATIOS The IT-SWITCH provides two main operating modes: - the manual transfer by the operator either locally or remotely (through the TOPVISIO supervision centre) - the automatic transfer by detection when the voltage of the preferred source exceeds the permitted values. The transfer is without sources overlapping..3.. Manual transfer The operator can control the load transfer from one source to the other by using keys or on the control panel. When pressing any keys, an audible beep is given to indicate that the request has been taken into account. The manual transfer is seamless. If synchronisation conditions are not fulfilled after 5 seconds (factory standard setting), an asynchronous transfer is performed. If the latter is impossible (e.g. input source out of tolerance) the following led lights! TRASFER IMPOSSIBLE ote: The alarm is automatically deleted when normal conditions are restored..3.. Automatic transfer The automatic transfer from the preferred source to the alternate one is seamless for the load. It is carried out if a voltage drop occurs on the preferred source or if the latter fails. When the preferred source is restored, the IT-SWITCH automatically transfers the load back to this source after 3 seconds. An automatic transfer from the alternate to the preferred source can also be performed following a manual transfer request.

18 UPS/TA GB/ITS6.E page 7 To ensure safe transfer, the IT-SWITCH constantly monitors if the alternate source is present and within the tolerances. If not, the transfer function is inhibited and the IT-SWITCH immediately gives the alarm to inform the operator that no transfer can be performed. In case of short-circuit on the output of one of the loads supplied, the transfer function is inhibited. This facility is for preventing the short-circuit transmission to the other path which is therefore left untouched. IMPORTAT: this functionality is not available on the IT-SWITCH model S Transfer can either be synchronous or asynchronous depending on the synchronisation of the sources and on the configuration of the IT-SWITCH. Synchronous transfer The synchronous transfer is automatic when both sources S and S fulfil synchronisation conditions, that are when the phase shift is within the values admitted (in standard +/- 5 ). In such case, the source switching does not cause changes of phase. If the phase shift exceeds the values admitted, the synchronous automatic transfer to the other source is inhibited, unless the system is set with the synchronous and asynchronous conditions (software configuration). OTE: The IT-SWITCH is set in standard for synchronous and asynchronous type transfers. It can however be set for synchronous transfers only if the load connected is sensible to phase changes. Most information processing equipment, servers, computers and so on, are not sensible to significant changes of phase. IMPORTAT: the IT-SWITCH model S can not be set for synchronous transfer only. Asynchronous transfer The automatic asynchronous transfer is only executed if the software setting has been validated (standard factory setting) and if sources S and S are not synchronised (phase shift exceeding the admitted values). In such a case, the source switching can show a significant change of phase. This type of transfer is for safe load switching between sources that are not constantly monitored or exceptionally out of phase Transfer blocked In the event of five consecutive automatic transfers within minutes (0 seconds), the alarm (or the alarm: 0 ) is given. At this stage, the transfer is blocked and the load is supplied by the alternate source. ote: to activate the transfer, press key or depending on the source preferred. IMPORTAT: the IT-SWITCH model S has no "transfer blocked" configuration

19 UPS/TA GB/ITS6.E page Load disconnection The load disconnection control is for load switching off, while sources and are present on the IT-SWITCH. The control key is :"alarm reset" (see.) Overload conditions As soon as the IT-SWITCH is overloaded (load rate > 03%) the general alarm is given. For currents and overload permitted values, please refer to 3. Operation on the preferred source: A request for transfer to the alternate source can be performed when the overload is half the nominal overload capacity. Two cases can arise: - if the transfer can be achieved, the load is transferred to the alternate source, - if the transfer is impossible, the IT-SWITCH gives the "imminent shutdown" alarm. When the maximum overload capacity is reached, the load is disconnected. Operation on the alternate source: In case of overload, the "imminent shutdown" alarm is given. When the maximum overload capacity is reached, the load is disconnected by the IT-SWITCH. Principle of the automatic start up: In case both sources fail while the IT-SWITCH is supplied by one or the other source, the unit resumes operation with the first one to be restored. The transfer to the preferred source is automatic when the latter is restored. The automatic start-up function can be configured and is activated by default.

20 UPS/TA GB/ITS6.E page 9 3. COMMISSIOIG - OPERATIO 3.. Preliminary checks Only initiate commissioning after completing: - earth bonding, - adequate connections of the IEC sockets (or connections to terminals). 3.. Safety - Reminders CAUTIO Even when switched off, the IT-SWITCH is constantly live, supply voltage is present at the input of source and. ADVICE Any loose item is secured. Do carefully follow the using or maintenance instructions described in the manual Preliminary conditions Source and Source are live Load supply From the control panel, press key:, for the load to be supplied by source, or, for the load to be supplied by source. If the operator selects the alternate source, the IT-SWITCH supplies the load from the source selected. However, the IT-SWITCH automatically switches the load to the preferred source after a few seconds Changing the source priority (models S, B and E) OTE: By default, source is preferred when switching on the unit. Press key for 5 seconds, and make sure that the led lights confirm the change of source. After changing the source priority, the load is automatically transferred, after a few seconds, to the newly preferred source.

21 UPS/TA GB/ITS6.E page Load disconnection Load disconnection opens the circuit of each source. The output is therefore no longer supplied. Press key "ALARM RESET" together with key or depending on the source that is supplying load current. At this stage the load is no longer supplied. OTE: If an alarm is displayed, it must be reset before sending any control. IMPORTAT: For an IT-SWITCH with manual bypass, the rack of the IT-SWITCH IS locked to the chassis and can not be removed as long as the switch is in position "" (normal operation). To remove the rack, cut off the input supply of sources and in order not to apply voltage to the load and place bypass the switch to position "" or "" Transfer to manual Bypass (IT-SWITCH Model E) The IT-SWITCH (model E) has two "manual bypasses": one to source and the other one to source. The load can be directly supplied by one or the other source. The manual bypass is controlled by 3-position switch located behind the access door in the front of the unit: - position "": position for normal operation, - position : manual bypass supplied by source, - position : manual bypass supplied by source Load transfer to manual bypass As each source has its "manual bypass", two cases can arise: a. the load is supplied by source : - open the access door on the front, - set the switch to position At this stage, the load is directly supplied by source. b. the load is supplied by source : - open the access door on the front, - set the switch to position At this stage, the load is directly supplied by source.

22 UPS/TA GB/ITS6.E page Return from manual bypass to the IT-SWITCH a. the load is supplied by manual bypass : On the rack of the IT-SWITCH : - open the access door on the front, - set the switch to "" At this stage the load is supplied through the IT-SWITCH. b. the load is supplied by manual bypass : On the rack of the IT-SWITCH: - open the access door on the front, - set the manual bypass switch to "". At this stage the load is supplied through the IT-SWITCH Seamless replacement of the electronic rack (IT-SWITCH model E) In normal operating conditions, the manual bypass switch is set to position "". Thus, the electronic rack is mechanically locked to the chassis in order to avoid any mishandling Removing the electronic rack Before pulling out the electronic rack, set the manual bypass switch to position or depending on the using conditions. Remove the rack; the load is still supplied by the selected path Replacing the electronic rack When repositioning the electronic rack, positions between the switch in the rack and the red marking on the chassis must correspond (see drawing below). The position of the manual bypass switch should correspond to the one indicated by the red marking on the chassis.

23 UPS/TA GB/ITS6.E page Operations to be performed: - open the access door on the front of the electronic rack, - place the manual bypass switch to the same position as the one indicated by the red marking on the chassis, - introduce the electronic rack into the chassis. 4. DESCRIPTIO OF THE VARIOUS STATES 4.. Transfer impossible The transfer becomes impossible if the conditions are as follows: - voltage outage or voltage out of tolerance on alternate source, - frequency out of tolerance, - phase on both sources out of tolerance and setting for synchronous transfer only - failure on the alternate source, - short-circuit downstream of the system. 4.. Imminent shutdown Conditions leading to imminent shutdown are as follows: - equipment ambient temperature fault, - overload alarm on preferred path supplying the load and transfer impossible (alternate source not available), - overload alarm on alternate path supplying the load. ote: the alarm IMMIET SHUTDOW informs the operator that the equipment is about to be stopped for safety reasons. 5. GEERAL ALARM The general alarm comprises: - imminent shutdown, - transfer impossible, - return impossible, - overload, - equipment ambient temperature.

24 SECTIO 4 UPS/TA GB/ITS6.E page 3 TROUBLE SHOOTIG AD MAITEACE 6. DIFFICULTIES DURIG COMMISSIOIG External causes: Check the connection and the presence of the power sources. In case of a malfunction, ensure neutral and phase connections are suitable on each source. If the green leds "Input voltage present on source " and "Input voltage present on source " are lit together with the orange led "transfer impossible", ensure that both sources have the same phase. For the proper functioning of the equipment, both supply sources should show: - the same voltage, - the same frequency, - the same phase. Internal causes, operation checking: If only the red led IMMIET SHUTDOW is lit, the electronic temperature has reached a critical level. 7. MAITEACE The IT-SWITCH is an equipment that was tested and set by the factory in compliance with quality requirement. Any internal intervention should only be made by personnel approved by SOCOMEC UPS. 8. TROUBLE SHOOTIG (See next page)

25 UPS/TA GB/ITS6.E page 4 A B C D E F G COSTAT POSSIBLE CAUSE OPERATIO TO BE PERFORMED Mimic panel not supplied Both input sources of the IT-SWITCH are absent Ensure that the source input voltage is present (no LED O) Connection problem Check that inputs S and/or S are connected Ensure that the rack (model E) has been properly inserted Impossible to switch Q50 Rack (ME) not properly inserted Pull out the rack, check the position of Q50 and set it to the initial position (Model E only) Q50 in the wrong position (I or II) Caution: before switching Q50 to the second source, ensure that it is present Slow blinking of the output red LED Short-circuit detected (and stored) on the load output Check the load output circuit in order to find out the anomaly before resetting the alarm. (mimic panel) Detection "temperature too high" Check the conditions of the unit environment: Rapid blinking of the output red LED T amb / cabinet ventilation / heat source close to the unit (mimic panel) Overload + Transfer impossible Refer to E (overload) Failure of one of the source Source absent or out of tolerances Refer to A (S or S) Manual bypass on the second source Supply the load via the second source and return to position "" Overload and operation on alternate source Ensure that the IT-SWITCH unit is not overloaded Overload capacity reached Reduce the load rate and wait for the power circuit to cool down Impossible to perform a manual transfer to the Refer to E Refer to E second source Alarm «Transfer blocked» O wrong contact on the input Check the tightening of input terminals and upstream protections (circuit breakers) Ensure that sources input cables are not damaged Preferred source not operating properly Ensure that the source is neither faulty nor overloaded H Blinking LED (source or ) Refer to E Sources are not synchronised And load on alternate source (after automatic transfer) And configuration "synchronous only" Refer E: Reduce the load Try to obtain the synchronisation between both sources GREE led SOURCE PREFERRED - light pressing: for alarm reset GREE led IPUT VOLTAGE PRESET O SOURCE or SOURCE GREE led ORAGE led RED led ORAGE led Fixed light on: SOURCE or SOURCE O Blinking: switch alarm (e.g. overload) TRASFER IMPOSSIBLE (second source not available or not synchronised) ( See.3..) Slow blinking: short-circuit current detected Rapid blinking: IMMIET SHUTDOW ( See 4..) Fixed light on: MAUAL BYPASS switch in position or MAUAL BYPASS of source or O (for IT-SWITCH model E). ot used for IT-SWITCH models S or B. - long pressing (5 seconds ): to select the preferred source - simultaneous pressing with key or : load disconnection Key is for the closing command of switch SW. Key is for the closing command of switch SW. ORAGE led ORAGE led GEERAL ALARM TRASFER BLOCKED (see.3.3.)

Montage- und Bedienungsanleitung

Montage- und Bedienungsanleitung Montage- und Bedienungsanleitung (Draft) Rittal STS (Rittal Static Transfer Switch) DK 7857.070 DK 7857.080 DK 7857.090 DK 7857.00 STS 7857.090 6 A STS 7857.00 0 A STATIC TRASFER SWITCH - 6A AD 0A USER'S

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

Pulsar EXtreme 2000/3000 VA

Pulsar EXtreme 2000/3000 VA www.mgeups.com MGE UPS SYSTEMS Pulsar EXtreme 2000/3000 VA Installation and user manual P O W E R P R O V I D E R L E I B E R R U P T N T N I E U T H 51033211EN/AC - Page 1 Introduction Thank you for selecting

More information

Model HM-535 Power Supply Installation and Service Instructions

Model HM-535 Power Supply Installation and Service Instructions Model HM-535 Power Supply Installation and Service Instructions 430-535 0104 2004 Heritage MedCall, Inc SENTRY INSTALLATION & SERVICE INSTRUCTIONS POWER SUPPLY UNIT Model HM-535 IMPORTANT SAFETY INSTRUCTIONS

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A PDU16-AV 20A AC PDU WITH POWER MONITOR 2U Rack Mount PDU with Overload Protection & Power Monitoring 2U high Horizontal Mounting unit designed to provide versatile hook-up for the distribution of AC power

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

OPERATING MANUAL PDUAC3U SERIES AC POWER DISTRIBUTION UNITS

OPERATING MANUAL PDUAC3U SERIES AC POWER DISTRIBUTION UNITS AC POWER DISTRIBUTIO UITS www.unipowerco.com Manual o. PDUAC3U-3 2017 UIPOWER LLC All Rights Reserved UIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com orth America:

More information

SAVE THESE INSTRUCTIONS

SAVE THESE INSTRUCTIONS READ AD FOLLOW ALL SAFETY ISTRUCTIOS! SAVE THESE ISTRUCTIOS AD DELIVER TO OWER AFTER ISTALLATIO IMPORTAT SAFETY ISTRUCTIOS! WARIG To reduce the risk of death, injury or property damage from fire, electric

More information

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A

Table of Contents. Automatic Transfer Switch. User Manual ATS-16A/20A/30A/32A Table of Contents 1. Important Safety Instructions... 2 2. Overview... 3 3. Product Functional Description... 4 3.1. Front Panel... 4 3.2. LCD Display Description... 5 3.3. Rear Panel... 6 3.4. Communication

More information

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual MIC-3001/8 3U/4U CompactPCI Enclosure for Rack Mounting User Manual Copyright The documentation and the software included with this product are copyrighted 2004 by Advantech Co., Ltd. All rights are reserved.

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting MIC-3001/8 3U/4U CompactPCI Enclosure for Rackmounting Copyright Notice This document is copyrighted, 1999. All rights are reserved. The original manufacturer reserves the right to make improvements to

More information

User Guide Automatic Transfer Switch (ATS)

User Guide Automatic Transfer Switch (ATS) User Guide Automatic Transfer Switch (ATS) V.1.0 Table of Contents 1. Introduction... 2 2. Product Overview... 2 3. Important Safety Warnings... 3 4. Operation Indicators & Status... 3 5. Installation...

More information

IPC194. ipconv Protocol Converter

IPC194. ipconv Protocol Converter IPC194 General Operating, Maintenance and Installation Manual ipconv Protocol Converter D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 78 Internet: http://www.ipcomm.de Email: info@ipcomm.de

More information

Chloride CROSS Rack 16 A, 32 A and 63 A

Chloride CROSS Rack 16 A, 32 A and 63 A AC Power for Business-Critical Continuity Chloride CROSS Rack 16 A, 32 A and 63 A STS Catalogue Chloride CROSS Rack High Voltage and Low Voltage 2 Pole Complete Reliability On-line Static Switch 16 A,

More information

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER / OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER PAGE 2 OF 17 INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Operating Instructions

Operating Instructions TPS S1 AC in DC out Translation of the original instructions TPS 110-400 Mains pack Operating Instructions PT 0199 BEN/C (1010) EN Table of contents Table of contents 1 About this manual...............................................

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power

USER MANUAL. Uninterruptible Power Supply Line-interactive VCL Series UPS VA. GE Critical Power Critical Power USER MANUAL Uninterruptible Power Supply Line-interactive VCL Series UPS 400 600 800 1000 1500 VA GE Consumer & Industrial SA General Electric Company CH 6595 Riazzino (Locarno) Switzerland

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side

More information

Electrical Actuators

Electrical Actuators 4 891 SSB without auxiliary switch SSB1 with auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB31 SSB81 SSB61 SSB31 operating voltage AC 230

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

Electrical Actuators

Electrical Actuators 4 891 SSB without auxiliary switch Electrical Actuators for small valves types VVP45, VXP45, VMP45 (max D25, k VS = 63 m 3 /h) SSB1 with auxiliary switch SSB31 SSB61 SSB81 SSB31 operating voltage AC 230

More information

DIGITAL TORQUE ADAPTOR

DIGITAL TORQUE ADAPTOR DIGITAL TORQUE ADAPTOR Model No: PRO238 PART NO: 1700638 OPERATING & MAINTENANCE INSTRUCTIONS GC12/16 INTRODUCTION Thank you for purchasing this CLARKE Torque Adaptor. This CLARKE product has been designed

More information

EX-RC1 Remote I/O Adapter

EX-RC1 Remote I/O Adapter EX-RC1 Remote I/O Adapter The EX-RC1 interfaces between Unitronics Vision OPLCs and remote I/O Expansion Modules distributed throughout your system. The adapter is connected to a PLC via CANbus. Each adapter

More information

CMC III Temperature/Humidity Sensor

CMC III Temperature/Humidity Sensor CMC III Temperature/Humidity Sensor DK 7030.111 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III temperature/humidity sensor (referred to hereafter

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE 3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE -ST-01 Page 1 of 10 November 2016 2016 Copyright Lite-On Technology Corporation ALL RIGHTS RESERVED. Lite-On is a trademark of Lite-On Technology

More information

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Rhino Redundancy Module PSM24-REM360S. Operating Instructions Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),

More information

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2

VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 VDI Pro Voltage & Dry Contact Interface Installation and programming Guide MODEL VDI MK2 1 of 18 PREFACE Important Installation Information It is the purchasers responsibility to determine the suitability

More information

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF

More information

Quick Start Guide and Health and Safety Information

Quick Start Guide and Health and Safety Information D397-10-880 Issue F Original Quick Start Guide and Health and Safety Information Turbo Instrument Controller (TIC) Description TIC Instrument Controller 3 Gauge TIC Instrument Controller 6 Gauge TIC Instrument

More information

1 Channel Strobe Controller ORDERCODE 40226

1 Channel Strobe Controller ORDERCODE 40226 1 Channel Strobe Controller ORDERCODE 40226 Congratulations! You have bought a great, innovative product from Showtec. The Showtec Strobe Controller brings excitement to any venue. Whether you want simple

More information

PSA200 User s Manual

PSA200 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

CPCI System Subrack 1 U

CPCI System Subrack 1 U User s Manual Product No.: Doc-No: 63972-165_R1.0 January 14, 2008 Rev. Date updated Change R1.0 January 14, 2008 Initial Release Impressum: Schroff GmbH D-75334 Straubenhardt, Germany The details in this

More information

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Rhino Buffer Module PSM24-BFM600S. Operating Instructions Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2

User Manual. Stoltzen SHSP14 HDMI Splitter 1x4. 4K HDMI Splitter 1x4. All Rights Reserved. Version: SHSP14_2016V2 User Manual 4K HDMI Splitter 1x4 All Rights Reserved Version: SHSP14_2016V2 SAFETY PRECAUTIONS To insure the best from the product, please read all instructions carefully before using the device. Save

More information

EOS-6000 Series Optical A/B Switch User Manual DC Version

EOS-6000 Series Optical A/B Switch User Manual DC Version EOS-6000 Series Optical A/B Switch User Manual DC Version For more information on this and other products: Contact Sales at EMCORE 626-293-3400, or visit www.emcore.com. Table of Contents Table of Contents...2

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER

OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER OPERATOR MANUAL OSD2153 SERIES GIGABIT ETHERNET MEDIA CONVERTER INDEX 1 1 TECHNICAL SUMMARY... 5 1.1 BRIEF DESCRIPTION... 5 1.1.1 OVERVIEW... 5 1.1.2 APPLICATIONS... 5 1.1.3 FEATURES AND BENEFITS... 5

More information

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW

LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW Product data sheet Characteristics LXM32SD18M2 motion servo drive - Lexium 32-single phase supply voltage 115/230V - 0.5/1.kW Main Range of product Lexium 32 Product or component type Device short name

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language

ALPHA Automated Transfer Switch Operating Manual. Rev 1.21 The original of this document is drawn up in English language ALPHA Automated Transfer Switch Operating Manual Rev 1.21 The original of this document is drawn up in English language ATS Manual Rev 1.21 Alpha Technologies GmbH 2013 Table of Contents 1. Safety Instructions...

More information

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/

Symmetra PX 160. Maintenance Bypass Enclosure. Installation 05/ Symmetra PX 160 Maintenance Bypass Enclosure Installation 05/2014 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries

More information

JanusRAID SA-6692J Hardware User Manual

JanusRAID SA-6692J Hardware User Manual JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements

More information

Channel Switch CS. General Operating, Maintenance and Installation Manual

Channel Switch CS. General Operating, Maintenance and Installation Manual Channel Switch CS General Operating, Maintenance and Installation Manual D-91056 Erlangen Phone: +49 9131 7677 47 Fax: +49 9131 7677 74 Internet: http://www.ipcomm.de Email: info@ipcomm.de Edition September

More information

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...

More information

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE User s Manual SR250HL Power Supply/ Float Charger for Lead Acid Batteries STANDARD FEATURES OPTIONAL FEATURES 3 Relay Alarms-Form

More information

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for

More information

IGLOO IGLOO EASY INSTRUCTION MANUAL

IGLOO IGLOO EASY INSTRUCTION MANUAL ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B SURGE PROTECTION PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) USER MANUAL Surge Protection Device B 01 156 9000 This Surge Protection Device is intended for professional use only Read this

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane MIC-3081 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane Advantech CompactPCI Modular Industrial Computer Copyright Notice This document is copyrighted, 2003. All rights are

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL Phone: (209) 586-1022 (800) 545-1022 Fax: (209) 586-1026 OTOHP-CH Rev. X1 E-Mail: salessupport@olsontech.com

More information

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE

OPERATOR MANUAL. OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER. WITH PoE SOURCE OPERATOR MANUAL OSD2053P SERIES MICRO 10/100Base-T to 100Base-X MEDIA CONVERTER WITH PoE SOURCE INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4

More information

User Manual PUH4-H2. 4K HDMI Splitter 1x4. All Rights Reserved. Version: PUH4-H2_2016V1.2

User Manual PUH4-H2. 4K HDMI Splitter 1x4. All Rights Reserved. Version: PUH4-H2_2016V1.2 User Manual PUH4-H2 All Rights Reserved Version: PUH4-H2_2016V1.2 Preface Read this user manual carefully before using this product. Pictures shown in this manual is for reference only, different model

More information

1395 Node Adapter Board Troubleshooting

1395 Node Adapter Board Troubleshooting 1395 Node Adapter Board Troubleshooting Specifications Electrical: Board power provided by Drive (+5V) Discrete Input 24V DC or 115V AC, jumper selectable Environmental: Ambient Operating Temperature Storage

More information

MANUAL. ENGLISH Showtec PSA-161 Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

MANUAL. ENGLISH Showtec PSA-161 Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands MANUAL ENGLISH Showtec PSA-161 V1 Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands Table of contents Warning... 2 Safety Instructions... 2 Operating Determinations... 4 Connection

More information

NI PXIe-1062Q Power Supply Shuttle

NI PXIe-1062Q Power Supply Shuttle USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National

More information

SMARTONLINE E3 UPS SYSTEMS

SMARTONLINE E3 UPS SYSTEMS SMARTONLINE E3 UPS SYSTEMS Extremely efficient protection for your most important equipment IDEAL OUTPUT POWER PROTECTS CRITICAL SYSTEMS On-line, double conversion operation continuously delivers precision-regulated,

More information

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection Product datasheet Characteristics ATS22D75S6U Complementary Assembly style Function available Supply voltage limits Main Range of product Altistart 22 Product or component type Product destination Product

More information

EMC1600 Series Media Converter and Ethernet Extender Chassis

EMC1600 Series Media Converter and Ethernet Extender Chassis EMC1600 Series Media Converter and Ethernet Extender Chassis User s Manual Preface This manual describes how to install and use the 16-Bay Media Converter and Ethernet Extender Chassis. This chassis is

More information

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE

NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE Introduction Unpacking The NI PXI-1042 power supply shuttle is a replacement part for the PXI-1042 chassis. To minimize downtime caused by a power-supply failure,

More information

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Characteristics soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100h Complementary Assembly style Function available Power supply voltage limits Main Range of product Altistart

More information

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0 BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS SECTION 264313 - TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and

More information

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

CEM M-RS485 INSTRUCTION MANUAL (M014B A) Communications interface CEM M-RS485 INSTRUCTION MANUAL (M014B01-03-14A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could

More information

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs The IO-DI8-TO8 and IO-DI8-TO8-L are I/O expansion modules that can be used in conjunction with specific Unitronics OPLC controllers. The

More information

1-36V, 0-3A DC Power Supply

1-36V, 0-3A DC Power Supply 1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative

VFI RTG PDU 6-10K. Installation and user manual. Service and support: Call your local service representative VFI RTG PDU 6-10K Installation and user manual Service and support: Call your local service representative SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. This manual contains important instructions that

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

NI PXI-1042 Series Power Supply Shuttle

NI PXI-1042 Series Power Supply Shuttle USER GUIDE NI PXI-1042 Series Power Supply Shuttle Introduction Unpacking The NI PXI-1042 Series power supply shuttle is a replacement part for the NI PXI-1042 Series chassis. To minimize downtime caused

More information

D-Pack 6 Classic ORDERCODE 50315

D-Pack 6 Classic ORDERCODE 50315 D-Pack 6 Classic ORDERCODE 50315 Congratulations! You have bought a great, innovative product from Showtec. The Showtec D-Pack 6 Classic brings excitement to any venue. Whether you want simple plug-&-play

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

LXM32AD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw Characteristics motion servo drive - Lexium 32 - three-phase supply voltage 208/480V - 1.8 kw Complementary Switching frequency Overvoltage category Leakage current Output voltage Electrical isolation

More information

D-Link Switch User Manual. Table of Contents

D-Link Switch User Manual. Table of Contents Table of Contents About This Guide... 1 Terms/Usage... 1 Copyright and Trademarks... 1 Product Introduction... 2 Package Contents... 2 Product Overview... 2 Front Panel... 2 Rear Panel... 2 Indicator LEDs...

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

Specifications, Installation, and Operating Instructions

Specifications, Installation, and Operating Instructions Specifications, Installation, and Operating Instructions Model: Power Vantage AC Panel Protector CAUTION: The installation of a surge protection device () must be done by qualified electrical personnel.

More information

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL 2 INTRODUCTION First and foremost we would like to thank you for purchasing this product. Our commitment to satisfying our customers can be seen

More information

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209

SINUS PENTA 6. ACCESSORIES 6.1. BRAKING RESISTORS APPLICATION TABLES 111/209 INSTALLATION. ACCESSORIES.. BRAKING RESISTORS... APPLICATION TABLES From size S to size S, inverters are supplied with a built-in braking module. The braking resistor is to be connected outside the inverter

More information

MANUAL ENGLISH PSA-63A4C. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

MANUAL ENGLISH PSA-63A4C. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands MANUAL ENGLISH PSA-63A4C V1 Highlite International B.V. Vestastraat 2 6468 EX Kerkrade the Netherlands Table of contents Warning... 2 Safety Instructions... 2 Operating Determinations... 4 Connection with

More information

Table of Contents. Safety. Attention. Warnings

Table of Contents. Safety. Attention. Warnings Solstart Miniature Soft Starter 8-58A, 220-600V Instruction Manual Ver. 21.2. 2002 Table of Contents Page Subject 3 Starter Selection 4 Installation Notes 5 Wiring 6 Starter Settings & Start-up Procedure

More information