Plug-in module SIRAX TV 808, 2 channels Isolating Amplifier unipolar/bipolar
|
|
- Mae Chambers
- 5 years ago
- Views:
Transcription
1 Plug-in module SIRAX TV 808, channels For electrically insulating, amplifying and converting DC signals Application The purpose of the isolating amplifi er SIRAX TV 808 (Fig. ) is to electrically insulate input and output signals, respectively to amplify and/or change the signal level or type (current or voltage) of the input signals. The instrument fulfi ls all the important requirements and regulations concerning electromagnetic compatibility EMC and Safety (IEC 00 resp. EN 6 00). It was developed and is manufactured and tested in strict accordance with the quality assurance standard ISO 900. The device has two channels and provides two independent isolating amplifi ers in an extremely small space. The user has a wide choice of input and output ranges and can set the desired one with the aid of soldered jumpers and potentiometers. A version with one input and two outputs is available that enables two electrically insulated outputs to be obtained from a single input signal. Variants 5 standard input and output combinations selected by soldered jumpers User-specific input and/or output ranges Isolating amplifier with one input and two electrically insulated outputs Power supply 4 60 V DC/AC or V DC/AC Please request our data sheet TV Le for single-channel versions. Features / Benefits Isolating amplifier plugs onto backplane (mechanically latched by fasteners), all electrical connections made to the backplane and not to the SIRAX TV 808 / Thus no wiring when replacing devices Electric insulation between inputs, outputs (.3 kv) and power supply 3.7 kv / Prevents measurement errors due to potential leakage Flexibility provided by more than 50 different input and output combinations selected by simply positioning soldered jumpers / Reduced stocking Non-standard user-specific ranges available AC/DC power supply / Universal Fig.. Plug-in module SIRAX TV for plugging onto backplane BP 90. Technical data Measuring inputs DC current: 0 0. ma 0. ma ma 0 0. ma 5 ma ma ma 0 ma ma 0 ma 4 0 ma ma 0 ma ma 0 5 ma 5 5 ma 0 0 ma 0 0 ma 0 0 ma 0 0 ma 0 0. to 0 40 ma or span 0. to 40 ma between 40 and 40 ma R i = 5 Ω Camille Bauer Data sheet TV Le 05.09
2 Plug-in module SIRAX TV 808, channels DC voltage: V 0. V V 0 0. V 5 V V 0 0. V 0 V V V 4 0 V V 0 V V 0 V 5 5 V 0 5 V 0 0 V 0 0 V 0 0 V 0 0 V 0 40 V to 0 40 or span 0.06 to 40 V between 40 and 40 V R i = 00 kω Overload: Measuring outputs DC current: Burden voltage: DC current continuously -fold DC voltage continuously -fold 0 0 ma, 4 0 ma, ± 0 ma 0 to 0 0 ma 0. to 4 0 ma 0 to ma V External resistance: R ext max. [kω] = V I AN [ma] DC voltage: I AN = Output circuit full-scale value 0 0 V, 0 V, ± 0 V 0 to 0 0 V 0. to 0 V 0 to V Burden: R ext min. [kω] U [V] AN 5 ma Current limiter at R ext max.: Voltage limiter at R ext = : U AN = Output circuit full-scale value Approx.. I AN for current output Approx. 3 V Power supply H AC/DC power pack (DC and Hz) Table : Nominal voltages and tolerances Nominal voltage U N Tolerance V DC / AC DC % V DC / AC AC ± 5% Power input: Accuracy data (acc. to DIN/IEC 770).6 W resp. 3.4 VA Basic accuracy: Limit error ± 0.% Including linearity and reproducibility errors Reference conditions: Ambient temperature Power supply Output burden 3 C, ± K 4 V DC ± 0% and 30 V AC ± 0% Current: 0.5 R ext max. Voltage: R ext min. Influencing factors: Temperature < ± 0.% per 0 K Burden infl uence < ± 0.% for current output < ± 0.% for voltage output if R ext < R ext min. Longtime drift < ± 0.3% / months Switch-on drift < ± 0.% Common and transverse mode infl uence < ± 0.% Output or connected to ground < ± 0.% Installation data Housing: Material of housing: Isolating amplifi er in housing B7 for plugging onto backplane BP 90. Refer to Section Dimensional drawing for dimensions Lexan 940 (polycarbonate) flammability class V-0 acc. to UL 94, self-extinguishing, nondripping, free of halogen Designation: SIRAX TV 808 Mounting position: Any Electrical connections: 96-pin connector acc. to DIN 4 6, pattern C Layout see Section Electrical connections Residual ripple in output current: Response time: 0.5% p.p. < 50 ms For power supplies > 5 V, the auxiliary circuit should include an external fuse with a rating 0 A DC. Data sheet TV Le Camille Bauer
3 Plug-in module SIRAX TV 808, channels Coding: Weight: Electrical insulation: Regulations Electromagnetic compatibility: Isolating amplifi er supplied already coded. The rack is coded by the user by fi tting the coding inserts supplied Approx. 0.8 kg All circuits (measuring input / measuring output / power supply) are electrically insulated The standards DIN EN and DIN EN are observed Protection (acc. to IEC 59 resp. EN 60 59): Housing IP 40 Terminals IP 00 Electrical standards: Acc. to IEC 00 resp. EN 6 00 Operating voltages: < 300 V between all insulated circuits Contamination level: Overvoltage category acc. to IEC 664: Double insulation: Test voltage: Environmental conditions Climatic rating: III for power supply II for measuring input and measuring output Power supply versus all other circuits Measuring input versus measuring output Power supply versus: all 3.7 kv, 50 Hz, min. Measuring inputs versus: measuring outputs.3 kv, 50 Hz, min. Measuring input versus: measuring input.3 kv, 50 Hz, min. Measuring output versus: measuring output.3 kv, 50 Hz, min. Climate class 3Z acc. to VDI/VDE 3540 Commissioning temperature: 0 to 55 C Operating temperature: 5 to 55 C Storage temperature: 40 to 70 C Annual mean relative humidity: 75% Altitude: Indoor use statement! 000 m max. Table : Ordering informations DESCRIPTION MARKING. Mechanical design Housing B7 (for plugging onto backplane BP 90, see data sheets BP 90). Number of channels channels 3. Version / Power supply Standard, 4 60 V DC/AC Standard, V DC/AC 4. Function inputs, electrically insulated outputs input, electrically insulated outputs 3 5. Input signal, input Input [V] 9 Input [ma] Z Line 9: [V] to 0 40 or span 0.06 to 40 V between 40 and 40 V Line Z: [ma] 0 0. to 0 40 or span 0. to 40 ma between 40 and 40 ma 6. Output signal, output Output [V] 9 Output [ma] Z Line 9: [V] 0 to to 0 0 to Line Z: [ma] 0 to to to Input signal, input Without input 0 Input [V] 9 Input [ma] Z Ranges possibles see input 8. Output signal, output Output [V] 9 Output [ma] Z Ranges possibles see output Possible special versions, e.g. increased climatic rating on inquiry. Camille Bauer Data sheet TV Le
4 Plug-in module SIRAX TV 808, channels Electrical connections SIRAX TV 808 Front SIRAX TV 808 Rear Fastener c b a Camille Bauer AG CH-560 Wohlen Switzerland Without function A B C D E F G H I U I U () ~ () ~ E E H SIRAX TV 808 Green LED for indicating device standing by I K L M A A Plug-in module SIRAX TV 808 a a3 a5 c7 c9 c c4 c6 a6 a8 a0 c4 Backplane Connecting allocation see Operating Instructions of backplanes I U I U () ~ () ~ E A E A H E = Input E = Input A = Output A = Output H = Power supply 4 Data sheet TV Le Camille Bauer
5 Plug-in module SIRAX TV 808, channels Configuration. Standard input ranges Soldered jumpers are provided for the coarse setting of the input ranges and the fi ne adjustment is accomplished using the potentiometers and. 00 must be added to the designations of the soldered jumpers in the table for channel and 00 for channel. (Example: Input range for input and input = 0 0 ma. Jumpers, 5, 6 and must be inserted for this range. The corresponding jumpers for channel are B 0, B 05, B 06 and B. The corresponding jumpers for channel are B 0, B 05, B 06 and B ) Current [ma] Soldered jumpers Voltage [V] Soldered jumpers, 3, 3, 4, 4, 4, 5, 5, 5 7, 0, 8, 9, 0, 7, 0, 8, 6, 7, 8, 0, 0, 6, , 9, 0, 7, 8, 0, 6, 8, 9, 7, 0 6, 7, 8, 0, 7, 8, 9, 8, 0 0, 6, , 4, 4, 5, 5 8, 0, 6, 9 6, 7, 0, 6, 7, 8,, 5, 5, 5, , 9, 0, 6, 8, 9, 0 6, 7, 0, 6, 7, 8,, 5, 5, 5, , 3, 3, 4, 4, 4, 5, 5, 5 8, 7, 9 7, 0, 8, 6, 9 0, 6, 6, , 8, 9, 6, 7, 9, 0 7, 8, 0, 7, 8, 9, 6, 8, 9, 0 0, 6, 8. Standard output ranges Soldered jumpers are provided for the coarse setting of the output ranges and the fi ne adjustment is accomplished using the potentiometers and. 3. Specific user output ranges Units that have been confi gured for a specifi c user output range cannot be subsequently reconfi gured. Current [ma] Soldered jumpers Voltage [V] 0 0 B 0 B B B 0 ± 0 ± 0 Soldered jumpers B 0 B B 3 B B B 3 B B 3 B 0 B B 3 B B B 3 B B 3 Camille Bauer Data sheet TV Le
6 Plug-in module SIRAX TV 808, channels B0 B0 B03 B04 B05 Standard accessories B B0 B06 B07 B08 B09 B0 B B B3 B4 B5 B6 B7 Operating Instructions for SIRAX TV 808 in three languages: German, French, English Coding comb with sets of codes 3 Data cards (for recording confi gured settings) B3 B B B0 B B3 Dimensional drawing 50.7 B0 B0 B03 B04 B05 B06 B07 B08 B09 B0 B B B3 B4 B5 B6 B7 Fig..Position of the soldered jumpers B and the potentiometers and Table 3: Accessories and spare parts Description Order No. Coding comb with sets of codes (for coding the backplane BP 90) Operating Instructions TV B d-f-e Data card (for recording confi gured settings) Fig. 3. SIRAX TV 808 in housing B Rely on us. Camille Bauer Ltd Aargauerstrasse 7 CH-560 Wohlen / Switzerland Phone: Fax: info@camillebauer.com Subect to change without notice Edition Data sheet TV Le
VR660 / A200R Programmable Modular Controller System
consisting of -channel top-hat rail controller modules (VR660) and a display and operating unit (A00R) Local bus Application The VR660 top-hat rail controller permits the design of autarkic, freely programmable
More informationMeasuring transducers MI4x0 series Programmable transducers for RTD sensors MI450
Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450 o Measuring of resistance of RTD sensors (Pt100, Pt1000, Ni100, Cu10,...) o Accuracy class up to: 0.5 o Programmable input
More informationKINAX WT720 absolute, programmable angular postion transmitter
For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive
More informationSUBJECT TO CHANGE WITHOUT NOTICE
Transducers & Isolators www.sifamtinsley.co.uk Multifunction Meters Transducers & Isolators Temperature Controllers Converters & Recorders Digital Panel Meters Current Transformers Analogue Panel Meters
More informationSAFE, FLEXIBLE, EASY CURRENT TRANSFORMER CURRENT TRANSFORMERS FOR THE SAFE MEASUREMENT OF HIGH CURRENTS
SAFE, FLEXIBLE, EASY FOR THE SAFE MEASUREMENT OF HIGH CURRENTS CURRENT TRANSFORMER CLIP-ON CORE-BALANCED OPEN-CORE FOR SAFE ENERGY ACQUISITION Camille Bauer and Gossen Metrawatt, your competent partners
More informationTHE NEXT TRANSDUCER GENERATION
THE NEXT TRANSDUCER GENERATION ADJUSTABLE HIGH-ACCURACY HEAVY-CURRENT SENSORS SINEAX DM5S/DM5F Heavy-current sensor for grid monitoring. SINEAX DM5S and SINEAX DM5F are freeprogrammable universal measurement
More informationData Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.
Data Sheet T 6493 EN TROVIS 6400 Automation System TROVIS 6493 Compact Controller For panel mounting (front frame 48 x 96 mm/1.89 x 3.78 inch) Application Digital controller to automate industrial and
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationDATA SHEET Selectable AC transducer, TAS-331DG
DATA SHEET Selectable AC transducer, TAS-331DG Measures power or reactive power on 3-phase AC networks Class 0.5 (IEC-688) measurement Supply and measuring voltage up to 690 V Easy configuration via PC
More informationFLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY
FLEXIBLE SOLUTIONS FOR THE ENERGY INDUSTRY COMPREHENSIVE INSTRUMENT FOR MEASUREMENT AND CONTROL OF POWER SYSTEMS CENTRAX CU-SERIES CENTRAX CU3000 CENTRAX CU5000 PAGE 2 Comprehensive instrument for measurement
More informationDATA SHEET Selectable AC transducer, TAS-321 DG
DATA SHEET Selectable AC transducer, TAS-321 DG Bi-directional current measurement on AC networks Power measurement using 2 phases on 3-phase networks Class 0.5 (IEC688) measurement Easy configuration
More informationDEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer
Installation and start up instructions TAS-331DG Selectable AC transducer 4189300008G (UK) Watt or var transducer Supply and measuring voltage up to 690V DEIF A/S Configuration via PC-interface possible
More informationLineMaster 100. Continuous-line Recorder. ABB Instrumentation 10/ EN
LineMaster 100 Continuous-line Recorder 10/43-1.10 EN 1 to 4 measuring channels Format 144 mm x 144 mm; installed depth 250 mm Combined chart unit for roll chart (32 m) or folded chart paper (16 m) Measuring
More informationIndicomp 4 Bargraph Indicator
Data Sheet 10/30-2.16-EN Indicomp 4 Bargraph Indicator Display is optionally LCD active: self-luminuous green on black self-luminuous green on blue LCD passive: self-luminuous black on light grey 2 input
More informationLineMaster 100 Continuous-line Recorder
Data Sheet 10/43-1.10-EN LineMaster 100 Continuous-line Recorder 1... 4 measuring channels Format 144 mm x 144 mm, installed depth 250 mm Combined chart unit For roll chart (32 m) or folded chart paper
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationPointMaster 100. Multipoint Recorder 10/ EN
PointMaster 1 Multipoint Recorder 1/41-1.1 EN 6 Measuring channels Last dot visible from the front Measuring channels electrically isolated and ungrounded Connection of process signals / 4...2 ma,...1
More informationDINALOG A 144 x 36 A1400 Light-Strip Indicator
DINALOG A x 6 A00 Light-Strip Indicator -9-0-0 /.00 Front panel dimensions: x 6 mm Light-strip indicator with 7 high-contrast LEDs Red LED display color Digital display range for portrait format: 999 to
More informationEMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks
Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008
More informationitemp TMT180 Technical information
Technical information itemp TMT180 Temperature head transmitter For resistance thermometers Pt100, settable using a PC, for installation in a sensor head Form B Application PC programmable (PCP) Temperature
More informationDigital Indicator DS 48/24 E
Data Sheet 10/33-2.04-EN Digital Indicator DS 48/24 E The indicator is suitable for measuring direct voltage or direct current. The units are installed in a rugged plastic housing and can be integrated
More informationVoltage Transducer UMT516 / MT516
Voltage Transducer UMT516 / MT516 True RMS AC voltage measurements Voltage auto range measurements up to 600V # Wide frequency measurement range 16 400 Hz High accuracy class 0.2 (IEC-688), 0.1 on communication
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationJUMO safetym TB/TW 08 Temperature limiter, monitor as per DIN EN
JUMO GmbH & Co. KG Delivery address: Mackenrodtstraße 14 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net
More informationOHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L
AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power
More informationPHOENIX CONTACT Features
Electronic monitoring relay for temperature monitoring Data sheet 107385_en_00 1 Description PHOENIX CONTACT - 2016-05-10 Features Safety and system availability requirements are constantly on the increase
More informationIST ULTRASTAB Power Supply for high precision transducers
IST ULTRASTAB Power Supply for high precision transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±0 V voltage output (see
More informationOverview of types. Technical data
echnical data sheet SH2A-MF.. Multifunctional linear actuators for adjusting air dampers and slide valves in ventilation and air-conditioning systems for building services installations For air control
More informationDuct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates
1 883 1883P01 1883P02 QFM4160 AQF4150 Symaro Duct Sensors for relative humidity and temperature with calibration certificates QFM41 Operating voltage AC 24 V / DC 1353 Signal output DC 010 V / 420 ma for
More informationTRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs
More informationSeries Watt DC Power Supplies
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Series 2268 850-Watt DC Power Supplies Specifications SPECIFICATION CONDITIONS This document contains
More informationEM2020 Selectable AC transducer A (UK)
Installation and start up instructions EM2020 Selectable AC transducer 4189300016A (UK) Watt or var transducer Supply and measuring voltage up to 690V Configuration via PC-interface possible FAGET 35 mm
More informationTechnical data. Safety parameters: see page 333. DC maximum residual ripple: 10% Supply voltage tolerance: DC consumption: Control circuit
Safety module CS DM-01 Technical data Housing PA 6.6 polyamide housing, self-extinguishing, V0 acc. to UL 94 Protection degree IP40 (housing), IP20 (terminal strip) Dimensions see page 283, design A Two-hand
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationElectronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet
Characteristics Single-function OFF-delay timer for DC contactors, without auxiliary voltage Width.5 mm CDC 5 6 F Approvals a culus f CCC CT-BS Circuit diagram Marker label Marks g c CE C-Tick Order data
More informationLED Driver Compact fixed output
Driver LC 100W 1100 2100mA flexc C EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter
More informationAnalog display for resistance current
www.reinhausen.com Analog display for resistance current Operating Instructions BA 2220061/01 NOTE The product may have been modified after this document went to press. We expressly reserve the right to
More informationTechnical data sheets
echnical data sheets Ready-to-connect spring return actuator with emergency function for VAV and CAV units in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m 2 orque
More informationDigital input modules
8 172 TX-I/O Digital input modules TXM1.8D TXM1.16D Two fully compatible versions: TXM1.8D: 8 inputs, each with a three-color LED (green, yellow or red) TXM1.16D: As TXM1.8X, but 16 inputs, each with a
More informationNon-Contact Safety System CES-AZ
Evaluation unit CE-AZ-AE-01B/ CE-AZ-UE-01B 1) 2) 1 read head can be connected 2 safety outputs (relay contacts with 2 internally connected NO contacts per output) tart button and feedback loop can be connected
More informationAPU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET
APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus
More informationLED Driver Linear / area dimming
Driver LC 75W 100 400mA 1-10V lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via 1... 10 V interface Dimming range 10 100 % (Depending on load. For details refer
More informationPower supply. Interface technology in modular housing DIN rail devices, IM series. Features
Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating
More informationData sheet Video Recorder LINAX A303
1 Technical data 1.1 Input 1.1.1 Analog multi-function input channel 1-6 Measured variable, measuring range To IEC 60873-1: An additional display error of -/+ 1 digit is permitted for every measured value.
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationRM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary
Characteristics voltage control relay RM35-U - range 194..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationCURRENT TRANSFORMER FOR THE SAFE MEASUREMENT OF CURRENTS SAFE FLEXIBLE EASY
CURRENT TRANSFORMER FOR THE SAFE MEASUREMENT OF CURRENTS SAFE FLEXIBLE EASY Current transformers for safe energy acquisition Camille Bauer and Gossen Metrawatt, your competent partners in heavy current
More informationLED Driver Linear / area fixed output
Driver LC 50W 100 400mA flexc lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via ready2mains Gateway Dimming range 13 100 % (Depending on load. For details refer
More informationLED Driver Linear / area fixed output
Driver LC 75W 900 1800mA flexc lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via ready2mains Gateway Dimming range 10 100 % (Depending on load. For details refer
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More informationPower supply module, bus connection module
s 8 183 8183p01, p02 TX-I/O Power supply module, bus connection module TXS1.12F10 TXS1.EF10 Each I/O row begins with one of these devices TXS1.12F10 power supply module Up to 4 power supply modules can
More informationLED Driver Linear / area dimming
Driver LC 75W 100 400mA 1-10V lp EXC EXCITE series Product description Built-in constant current LED Driver Dimmable via 1... 10 V interface Dimming range 10 100 % (Depending on load, for details refer
More informationHigh-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000
Universal high-voltage isolator. Input voltages up to Vin = ±3600 V. The Task In high-voltage systems, unipolar or bipolar voltage signals ranging from 100 V to 3600 V must be galvanically isolated and
More informationSignal Doublers. VariTrans A 20300
ProLine Interface Technology Signal Doublers Signal doublers with two switchable calibrated outputs in a 6 mm housing, also for applications with high output loads. The Task Isolation and transmission
More informationNon-communicating room controllers
3 882 DESIGO RXA Non-communicating room controllers RXA29.1 For fan-coil systems The RXA29.1 room controller are used for temperature control in individual rooms. For 2-pipe or 4-pipe fan-coil systems,
More informationMINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:
Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration
More informationSITOP 3-phase 24 V DC, 20 to 40 A
Siemens AG 2013 SITOP 3-phase, 20 to 40 A /2 SITOP 20 A /2 SITOP 20 A /2 20 A /3 SITOP PSU300B 30 A /3 SITOP 40 A /3 SITOP 40 A /3 40 A /8 Ordering data and further information For AL and ECCN export regulations
More informationLED Driver Compact fixed output
Driver LC 17W 250 700mA flexc SR EXC EXCITE series Product description Constant current LED Driver Dimmable via ready2mains Gateway Dimming range 15 100 % (Depending on load. For details refer to chapter
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationXE2 DC current relay for loss of excitation protection. Manual XE2 (Revision A)
XE2 DC current relay for loss of excitation protection Manual XE2 (Revision A) Woodward Manual XE2 GB Woodward Governor Company reserves the right to update any portion of this publication at any time.
More informationIST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers
Power Supply for IT/ITN ULTRASTAB transducers High performance 6-channel power supply for multi-channel laboratory measurement applications. Features Current output or ±10 V voltage output Six individual
More informationE-STOP relays, safety gate monitors
Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel 1/2 Supply voltage See
More informationSIPLUS S7-200 PS 203. Overview
SIPLUS S7-200 PS 203 Overview Design and functionality of the power supply are optimally adapted to the SIPLUS S7-200 micro PLC Slim design Particularly suitable for low cabinet depths Note: SIPLUS extreme
More informationUse. Functions. OpenAir TM. Linear version, modulating, AC 24 V
4 666 OpenAir TM Air damper actuators Linear version, modulating, AC 24 V GBB16...2 Electromotive linear actuators, DC 0...10 V modulating control signal, nominal force 440 N, operating voltage AC 24 V,
More informationRMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B
3 136 Synco 700 Extension odules for heating controller RH760B RZ782B RZ783B Extension modules for use with the RH760B heating controller to provide additional auxiliary functions Use Heating plants controlled
More informationElectronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationSwitch Mode Power Supply S8VT 120/240/480/960 W Models
Switch Mode Power Supply 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC 3 phase 400 to 500 VAC 5, 10, 20 and 40 A; 24 VDC output
More informationProximity sensors SME-8, for T-slot Technical data Magnetic reed
Function e.g. N/O contact, with cable, 3-wire Magnetic reed measuring principle Insertable in the slot lengthwise e.g. N/O contact, with plug, 3-pin SME-8-SL Sturdy thanks to long guides Plug directly
More informationArticle No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.
Product Name Type of power supply Electrical data Input Waveform of the input Supply Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.6A DC; NEC Class 2 single-phase AC Power Supply SCALANCE
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationE-STOP relays, safety gate monitors
E-STOP relays, safety gate monitors Up to Category 2, EN 954-1 Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button
More informationElectronic timer CT-AHS OFF-delayed with 2 c/o contacts Data sheet
2CDC 251 113 F0004 CT-AHS 1 7 2 6 5 4 8 3 1 10 selectable time ranges, from 0.05 s to 300 h 2 Potentiometer with direct reading scale for the fine adjustment of the time delay 3 Sliding switch to set the
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationSwitching relay CT-IRS with 1, 2 or 3 c/o contacts Data sheet
1SVR 430 221 F7300 2 1 3 Characteristics Switching relay ON-delay approx. 10 ms 1, 2 or 3 c/o contacts Switching relay with gold-plated contacts Width 22.5 mm Approvals e f GOST CCC CT-IRS 1 U/R: green
More informationElectromotive actuators for combi valves
s 4 833 ACVATIX Electromotive actuators for combi valves For combi valves VPF43.. and VPF53.. SQV..P.. SQV91.. Operating voltage AC/DC 24 V, Positioning signal 3-position, DC 0-10 V, DC 4-20 ma Position
More informationRoom sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates
1 859 1859P01 1859P02 1859P04 QFA4160 QFA41 D AQF4150 AQF3153 Symaro Room sensors for relative humidity and temperature with calibration certificates QFA41 Operating voltage AC 24 V / DC 13.5...3 Signal
More informationControl elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.
On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationSRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s
SRQ24A Rotary actuator for ball valves orque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s echnical data Electrical data Nominal voltage AC 24V, 50/60Hz / DC 24V Nominal voltage range
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationDemonstration Case BENNING DB 1
Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...
More informationPositive-guided relay outputs: 4 safety contacts (N/O), instantaneous
ohne Abbildung Contact expansion module for increasing the number of available contacts Approvals PZE X4.1P with universal power supply Unit features Positive-guided relay outputs: 4 safety contacts (N/O),
More information02/11/2015
DIN Rail Mount 22.5 mm ETM2 Part number 84874023 Version ETM : Controls temperature of machines using built-in PTC probes Line break or probe short-circuit detection Version ETM2 / ETM22 : Fault latching
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationM-bus web server. Meters and Energy Cost Allocation WTV676-HB6035
Meters and Energy Cost Allocation M-bus web server WTV676-HB6035 The web server reads out wireless or wired M-bus devices over Ethernet or the Internet using a browser. Power and connection for up to 20
More informationAlarm Unit DG 3200 Control And Monitor Standard Signals
Alarm Unit DG 3200 Control And Monitor Standard Signals With the Alarm Unit DG 3200 DRAGO is extending its offer on high-functional and high-reliable components of the interface technique. The Alarm Unit
More informationPower consumption In operation At rest For wire sizing
echnical data sheet Modulating damper actuator for adjusting air control dampers in ventilation and airconditioning systems for building services installations For air dampers up to approx 08 m orque Nm
More informationTXM1.8U TXM1.8U-ML. Universal modules TX-I/O
8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility
More informationImmersion Temperature Sensors
1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or
More informationEnglish. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM
English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationIRI1-ES Sensitive Earth Fault Current Relay. Manual IRI1-ES (Revision A)
IRI1-ES Sensitive Earth Fault Current Relay Manual IRI1-ES (Revision A) Woodward Manual IRI1-ES GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information
More informationVEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA
Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationVEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA
4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status
More informationIB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description
INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma Data sheet 105597_en_01 PHOENIX CONTACT 2014-10-24 1 Description The module is designed for use within an ST station. It is
More informationLineMaster 200. Continuous-line Recorder. ABB Instrumentation 10/ EN
LineMaster 200 Continuous-line Recorder 10/43-2.10 EN 1 to 4 measuring channels With text printout (optionally) Format 144 mm x 144 mm; installed depth 250 mm Multi-function desk for continuous rollpaper
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationTechnical data sheet. Technical data
echnical data sheet LMQ4A Damper actuator for adjusting air control dampers in ventilation and air-conditioning systems for building services installations For air dampers up to approx 8 m orque 4 Nm Nominal
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More informationExtension module for lighting control
s 3 842 DESIGO RXC Extension module for lighting control Extension to the RXC30 / RXC31 / RXC38 room controller RXC40.1 RXC40.5 The RXC40 extension module is used in conjunction with an RXC30, RXC31 or
More information