Getting Started Edition 10/2008

Size: px
Start display at page:

Download "Getting Started Edition 10/2008"

Transcription

1 Getting Started Edition 10/2008 Control Units CU240D DP 3.2 CU240D DP-F 3.2 CU240D PN 3.2 CU240D PN-F 3.2 Power Module PM250D Firmware version 3.2 SINAMICS G120 D s

2

3 Manual Collection and Online Document Support 1 Warnings and Cautions 2 SINAMICS SINAMICS G120D Getting Started Mechanical Installation 3 Electrical Installation 4 Check List 5 Commissioning 6 Factory Reset 7 Diagnostics A Edition 10/2008, Firmware version A5E A AB

4 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Proper use of Siemens products Note the following: Trademarks WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach NÜRNBERG GERMANY Ordernumber: A5E A AB P 09/2008 Copyright Siemens AG Technical data subject to change

5 Table of contents 1 Manual Collection and On-line Document Support Warnings and Cautions Mechanical Installation Ambient operating conditions Electrical Installation Settings PROFIBUS DP address with DIP switches Connecting the PROFINET interface Check List Commissioning Commissioning the application Factory Reset A Diagnostics Getting Started, , A5E A AB 5

6

7 Manual Collection and On-line Document Support 1 SD Manual Collection The SD Manual Collection is a complete collection of all Standard Drives documentation across the entire range of Standard Drives products, including Inverters, Motors and Geared- Motors. It is available to order as a DVD which runs in its own java-driven HTML interface. The order number for the SD Manual Collection is: 6SL3298-0CA00-0MG0 On-line documentation All Standard Drives documentation is available on-line at the following site: All documents are available for download, including Operating Instructions and Parameter Lists. Device description files (GSD) The device description files (GSD) are used to integrated an Inverter into a higher level control device, for example, SIMATIC S7. The required GSD files can be downloaded from the internet at the following site: Getting Started, , A5E A AB 7

8

9 Warnings and Cautions 2 General WARNING This equipment contains dangerous voltages and controls potentially dangerous rotating mechanical parts. Non-compliance with the Warnings or failure to follow the instructions contained in this manual can result in loss of life, severe personal injury or serious damage to property. Only suitable qualified personnel should work on this equipment, and only after becoming familiar with all safety notices, installation, operation and maintenance procedures contained in this instruction. The successful and safe operation of this equipment is dependent upon its proper handling, installation, operation and maintenance. The power supply, DC and motor terminals, the brake and thermistor cables can carry dangerous voltages even if the inverter is inoperative. Wait at least five minutes to allow the unit to discharge after switching off the line supply before carrying out any installation work. As the earth leakage for this product can be greater than 3.5mA a.c., a fixed earth connection is required and the minimum size of the protective earth conductor shall comply with the local safety regulations for high leakage current equipment. It is strictly prohibited for any mains disconnection to be performed on the motor-side of the system; any disconnection of the mains must be performed on the mains-side of the Inverter. When connecting the line supply to the Inverter, make sure that the terminal case of the motor is closed. When changing from the ON to OFF-state of an operation if an LED or other similar display is not lit or active; this does not indicate that the unit is switched-off or powered-down. The inverter must always be grounded. Isolate the line supply before making or changing connections to the unit. Ensure that the inverter is configured for the correct supply voltage. The inverter must not be connected to a higher voltage supply. Take particular notice of the general and regional installation and safety regulations regarding work on dangerous voltage installation (e.g. EN 50178) as well as the relevant regulations regarding the correct use of tools and personal protective equipment (PPE). CAUTION Children and the general public must be prevented from accessing or approaching the equipment! This equipment may only be used for the purpose specified by the manufacturer. Unauthorized modifications and the use of spare parts and accessories that are not sold or recommended by the manufacturer of the equipment can cause fires, electric shocks and injuries. Getting Started, , A5E A AB 9

10 Warnings and Cautions NOTICE Keep these instructions within easy reach of the equipment and make them available to all users. Whenever measuring or testing has to be performed on live equipment, the regulations of Safety Code BGV A2 must be observed, in particular 8 "Permissible Deviations when Working on Live Parts". Suitable electronic tools should be used. Before installing and commissioning, please read the safety instructions and warnings carefully and all the warning labels attached to the equipment. Make sure that the warning labels are kept in a legible condition and replace missing or damaged labels. Ensure that the appropriate circuit-breakers/fuses with the specified current rating are connected between the power supply and the inverter. These instructions assume that the user is fully conversant with the use of the following technologies: - PLCs - The commissioning software STARTER - PROFIdrive profiles and protocols. The commissioning procedure outlined in this manual is for Standard Inverters only - Failsafe commissioning is covered in the Operating Instructions. 10 Getting Started, , A5E A AB

11 Mechanical Installation 3 General layout of SINAMICS G120D Figure 3-1 SINAMICS G120D Inverter Getting Started, , A5E A AB 11

12 Mechanical Installation Fitting the Control Unit to the Power Module The inverter is delivered as two separate components - the Power Module (PM) and the Control Unit (CU). The CU must be fitted to the PM prior to any further commissioning taking place. CAUTION Seals fitted correctly It is important that when assembling the Power Module and the Control Unit that all the seals are fitted correctly to ensure IP65 rating. TN and TT mains supplies The SINAMICS PM250D Power Module with the Class A integrated mains filter is only suitable for operation on TN and TT mains supplies. The CU is fitted to the PM as shown in the diagram below. Figure 3-2 Fitting the Control Unit to the Power Module 12 Getting Started, , A5E A AB

13 Mechanical Installation Drill pattern for the SINAMICS G120 D inverter The inverter has an identical drill pattern for all frame sizes. The drill pattern, depth and tightening torques are shown in the diagram below. )6$ GHSWK )6% GHSWK )6& GHSWK PP ರ PP ರ PP ರ )L[LQJ PHWKRG [ 0 EROWV [ 0 QXWV [ 0 ZDVKHUV 7LJKWHQLQJ WRUTXH 1P OEI LQ ZLWK ZDVKHUV ILWWHG PP ರ 6,1$0,&6 * ' )UDPH VL]HV $ % DQG & PP ರ Figure 3-3 Drill pattern SINAMICS G120 D Mounting orientation The inverter has been designed to be table-mounted or side-mounted, it cannot be mounted upside-down. The minimum clearance distances are as follows: Side-by-side - no clearance distance is required Above and below the inverter 150 mm (5.9 inches). Figure 3-4 Correct Inverter orientation Getting Started, , A5E A AB 13

14 Mechanical Installation 3.1 Ambient operating conditions Temperature The operating temperature range is shown diagramatically in the figure below: Figure 3-5 Power derating for temperature Humidity range Relative air humidity for the SINAMICS G120D is 95 % non-condensing. Altitude If the SINAMICS G120D is to be installed at an altitude > 1000 m (> 3280 ft) derating will be required. The figures below show the derating required according to altitude. Figure 3-6 Derating for altitude Shock and vibration Do not drop the SINAMICS G120D or expose to sudden shock. Do not install the SINAMICS G120D in an area where it is likely to be exposed to constant vibration. 14 Getting Started, , A5E A AB

15 Mechanical Installation Electromagnetic radiation Do not install the SINAMICS G120D near sources of electromagnetic radiation. Atmospheric pollution and water When fully assembled the inverter has an IP65 rating. This means that the inverter is totally protected against dust and low pressure jets of water. Any unused connections should be covered with the correct sealing caps to ensure the IP65 rating. Getting Started, , A5E A AB 15

16

17 Electrical Installation 4 Power Module specifications - 3AC 380 V V ± 10 % Table 4-1 Rated Output, Input and Fuses Product Frame size rated output HO rated output current rated input current 6SL3525- kw hp A A A Type 0PE17-5AA0 A PE21-5AA0 A PE23-0AA0 B PE24-0AA0 C PE25-5AA0 C PE27-5AA0 C fuse For further technical information, please refer to the Operating Instructions. 3NA3 Group fusing Group fusing is where one circuit breaker or fuse is intended to provide protection for two or more devices. The protection device is called a branch circuit protection (BCP) device. For more information, please read the following FAQ: Getting Started, , A5E A AB 17

18 Electrical Installation Connections and cables WARNING Switches and contactors Under no circumstances shall any kind of switch or contactor be placed in the circuits between the Inverter and the motor. For maintenance, ensure that the motor cable is unplugged at the Inverter. Temperature sensor and brake module connections The temperature sensor and brake module connections are at DC link negative potential. Appropriate precautions against touching these connections and appropriate insulation on the cables must be used. The motor terminal box must be kept closed whenever the mains is applied to the Inverter. Cables that are not used should be individually insulated and not earthed. The following block diagram and tables describe the details and limitations of the connections of the inverter. Cable lengths All inverters will operate at full specification with motor cable lengths as follows: Screened - 15 m (49 ft) Unscreened - 30 m (98 ft) 18 Getting Started, , A5E A AB

19 Electrical Installation Outline block diagram Figure 4-1 Outline block diagram SINAMICS G120D Note Brake voltage The brake output of the Inverter is designed to be connected directly to the coil of the brake within the motor, that is, no rectifier module is required within the motor. For operation on a 400 V AC supply the brake should be rated for approximately 180 V DC (400 V AC with rectifier). The UL approved current rating for the brake output is 600 ma. Getting Started, , A5E A AB 19

20 Electrical Installation PROFIBUS block diagram Figure 4-2 PROFIBUS block diagram 20 Getting Started, , A5E A AB

21 Electrical Installation PROFINET block diagram Figure 4-3 PROFINET block diagram Getting Started, , A5E A AB 21

22 Electrical Installation Cable, connectors and tools specifications The detailed specifications for the cables, connectors and tools required to manufacture the necessary cables for the SINAMICS G120D are listed in the following tables. NOTICE NFPA compatibility These devices are intended only for installation on industrial machines in accordance with the "Electrical Standard for Industrial Machinery" (NFPA79). Due to the nature of these devices they may not be suitable for installation accordance with the "National Electrical Code" (NFPA70). Table 4-2 Tools Harting part number Crimp tool (Q8/0 and Q4/2) Removal tool (Q8/0) Removal tool (Q4/2) No special tools are required for the Control Unit connectors Table 4-3 Control Unit connectors Connector Binder part numbers Straight connector Right-angle connector Power input (7/8" ) Power Output (7/8" ) PROFIBUS In (M12 ) PROFIBUS Out (M12 ) PROFINET Port 1 and Port 2 (M12) Encoder (M12 ) Digital input and output (M12 ) Getting Started, , A5E A AB

23 Electrical Installation Table 4-4 Mains supply connector Power rating 0.75 kw 1.50 kw 3.00 kw 4.00 kw 5.50 kw 7.50 kw cable size 1.5 mm 2 16 AWG 2.5 mm 2 14 AWG 4 mm 2 12 or 10 AWG cable type (3+E) YY Unscreened (3+E) YY Unscreened (3+E) YY Unscreened 4 x crimps are required for each inverter All connector parts are Harting Q4/2 Shell Crimp Crimp number Hood Gland/Seal size Harting Q4/ mm 2 16 AWG 2.5 mm 2 14 AWG 4 mm 2 12 or 10 AWG Table 4-5 Motor connector Power rating 0.75 kw 1.50 kw 3.00 kw 4.00 kw 5.50 kw 7.50 kw cable size 1 mm 2 18 AWG 2.5 mm 2 14 AWG 4 mm 2 12 or 10 AWG Belcom "DESINA" Cable No. All connector parts are Harting Q8/0 Shell Crimp size 13EBN17Z08P Harting Q8/ mm 2 18 AWG 13EBN13Z08P mm 2 14 AWG 13EBN11Z08P 4 mm 2 12 or 10 AWG 4 x crimps are required for each inverter for the motor connections Crimp number Hood Gland/Seal LUTZE (NOT Harting) Table 4-6 Temperature sensor and EM brake Power rating 0.75 kw 1.50 kw 3.00 kw 4.00 kw 5.50 kw 7.50 kw cable size 1 mm 2 18 AWG 2.5 mm 2 14 AWG 4 mm 2 12 or 10 AWG Belcom "DESINA" Cable No. 13EBN17Z08P 0.75 mm 2 20 AWG 13EBN13Z08P 1 mm 2 18 AWG 13EBN11Z08P 1 mm 2 18 AWG 2 x crimps are required for each auxiliary signal pair Temperature sensor pair EM Brake pair Crimp size Crimp number Crimp size Crimp number mm 2 20 AWG mm 2 18 AWG mm 2 16 AWG Getting Started, , A5E A AB 23

24 Electrical Installation Connection specifications Table 4-7 Mains supply and motor output specifications Mains supply Motor output Pin Function Pin Function 1 L1 1 U 2 L2 2 Not connected 3 L3 3 W 4-4 EM Brake (-) 11-5 Temperature sensor (+) 12-6 EM Brake (+) PE Protective Earth 7 V 8 Temperature sensor (-) PE Protective Earth Type HAN Q4/2 (Male) Type HAN Q8 (Female) Spec. 3AC 380V...480V ± 10% Spec. - Table 4-8 External logical 24 V supply specifications External logical 24 V supply (IN) External logical 24 V supply (OUT) Pin Function Pin Function 1 Switched 0 V (2M) 1 Switched 0 V (2M) 2 Unswitched 0 V (1M) 2 Unswitched 0 V (1M) 3 Functional Earth 3 Functional Earth 4 Unswitched +24 V (1L+) 4 Unswitched +24 V (1L+) (5A max.) 5 Switched +24 V (2L+) 5 Switched +24 V (2L+) (5A max.) Type 7/8" - 16UN (Male) Type 7/8" - 16UN (Female) Notes 1. The CU metalwork is separated from high voltage circuits by reinforced insulation and so protective earth is not required. 2. PROFIBUS: The maximum current drawn on the unswitched 24 V supply is 750 ma for a unit with a fan and 600 ma for a unit without a fan. The maximum current drawn on the switched 24 V supply is 1 A. 3. PROFINET: The maximum current drawn on the unswitched 24 V supply is 850 ma for a unit with a fan and 700 ma for a unit without a fan. The maximum current drawn on the switched 24 V supply is 1 A. External 24 V supply The unswitched and switched 24 V supply are provided using appropriate external sources. The unswitched 24 V supply is designed to provided permanent power to the internal control electronics, the power module electronics, the digital inputs and the encoder input. The switched 24 V supply is provided to power only the digital outputs - these outputs are 24 Getting Started, , A5E A AB

25 Electrical Installation isolated from the rest of the drive electronics. This configuration allows the digital outputs to be switched on or off without disrupting the normal functioning of the Inverter. Table 4-9 PROFIBUS connectors specifications PROFIBUS (IN) PROFIBUS (OUT) Pin Function Pin Function 1 Not connected 1 Not connected 2 Data A (N) 2 Data A (N) 3 Not connected 3 Not connected 4 Data B (P) 4 Data B (P) 5 Functional Earth 5 Functional Earth Shield Functional Earth Shield Functional Earth Type M12-5 pole (Male) Type M12-5 pole (Female) Table 4-10 PROFINET connector specifications PROFINET Port 1 and Port 2 Pin Function 1 Transmission data + 2 Receive data + 3 Transmission data - 4 Receive data - Shield Functional Earth Type M12-4 pole (Female) [Both ports have identical connections] Table 4-11 Digital input and output specifications Digital input (4 sockets, 6 DIs) Digital output (2 outputs) Pin Function Pin Function 1 Unswitched +24 V (25mA max.) 1 Not connected 2 DI1,DI3 or NC 2 DO1 (0.5A max.) 3 Unswitched 0 V 3 Switched 0 V 4 DI0,DI2,DI4 or DI5 4 DO0 (0.5A max.) 5 Functional Earth 5 Functional Earth Shield Functional Earth Shield Functional Earth Type M12-5 pole (Female) Type M12-5 pole (Female) Spec PNP, SIMATIC-compatible, low < 5 V, high > 10 V, max. input voltage 30V Getting Started, , A5E A AB 25

26 Electrical Installation Table 4-12 Encoder connection specifications Encoder connections Pin Function 1 Channel A 2 Channel A' 3 Channel B 4 Channel B' 5 Channel Z 6 Channel Z' 7 Unswitched 24 V (100mA max.) 8 Unswitched 0 V Shield Functional Earth Type M12-8 pole (Female) 4.1 Settings PROFIBUS DP address with DIP switches Setting the PROFIBUS DP address Prior to using the PROFIBUS DP interface, the address of the node (inverter) must be set. There are two methods for setting the PROFIBUS DP address: Using the seven PROFIBUS DP address DIP switches on the Control Unit Using parameter "P0918". The PROFIBUS DP address can be set between 1 and 125. Note The address is taken from P0918 if all PROFIBUS DP address DIP switches are in the OFF position, otherwise the DIP switch setting is valid. CAUTION The external 24 V power supply must be switched off before the DIP switch settings are changed. DIP switch setting changes do not take effect until the Control Unit has been powered-up again. Setting the PROFIBUS DP address via DIP switches The PROFIBUS DP address can be set via DIP switch, as shown in the table below. 26 Getting Started, , A5E A AB

27 Electrical Installation Table 4-13 Example address for the PROFIBUS DP interface DIP switch Add to address Example 1: Address = 3 = Example 2: Address = 88 = Connecting the PROFINET interface Installing the PROFINET communications The CU240D PN and CU240D PN-F Control Units are equipped with two identical M12 Ethernet ports as previously described in this manual. Making the cables The Ethernet cable will consist of a M12 (Male) connection on one end of the cable and an RJ45 connector on the other end of the cable. The M12 connects directly to the Control Unit and the RJ45 connector can be used to connect to either the controlling PLC or a local PC. The assembly of the SIMATIC NET Industrial Ethernet FastConnect RF45 Plug 180 is described in the product information "Assembly Instructions for SIMATIC NET Industrial Ethernet FastConnect RJ45 Plug". For downloading this document, refer to: Table 4-14 PIN assignment of the RJ45 female socket Pin Designation Meaning Core color 1 TX+ Transmission data + Yellow 2 TX- Transmission data - Orange 3 RX+ Receiver data + White RX- Receiver data - blue Getting Started, , A5E A AB 27

28 Electrical Installation Connector Table 4-15 Recommended PROFINET connectors Order Number 6GK1901-1BB10-2Ax0 Label Industrial Ethernet FC RJ45 Plug 180 Max. baud rate 100 Mbit/s; Cat5e Outgoing cable unit 180 Degree of protection IP20 Operating temperature -20 C +70 C Industrial Ethernet Cables and cable length Listed in the table below are the recommended Ethernet cables. Table 4-16 Recommended PROFINET cables Industrial Ethernet FC TP Standard Cable GP 2 x 2 Industrial Ethernet FC TP Flexible Cable GP 2 x 2 Industrial Ethernet FC Trailing Cable GP 2 x 2 Industrial Ethernet FC Trailing Cable 2 x 2 Industrial Ethernet FC Marine Cable 2 x 2 Max. Cable Length Order Number 100 m (328 ft) 6XV1840-2AH10 85 m (278 ft) 6XV1870 2B 85 m (278 ft) 6XV1870 2D 85 m (278 ft) 6XV1840 3AH10 85 m (278 ft) 6XV1840 4AH10 Cable installation rules Screening The screen of the PROFINET cable must be connected with the protective earth. The solid copper core must not be scored when the insulation is removed from the core ends. 28 Getting Started, , A5E A AB

29 Check List 5 Installation check list Before power is applied to the inverter/motor system, the following checks should be performed: Check that: 1 The environmental conditions conform to the inverter/motor specifications 2 The inverter and the motor are securely mounted 3 The inverter and motor are correctly installed with adequate cooling provision 4 The motor and the application/equipment are ready to start, i.e. safe state - motor can rotate 5 The inverter is correctly earthed/grounded 6 The input power (supply) voltage matches the inverter's nominal input voltage 7 The input power (mains) fuses are the correct type and installed correctly 8 The motor connections are connected to ensure the correct direction of rotation of the motor at start-up 9 The motor and mains connections are connected and tightened to the required specification 10 The motor connections are not reversed - the motor will start but serious damage may occur to the connected equipment 11 The motor cable is routed away from other cables 12 The control connections are connected and tightened to the required specification 13 No tools or other objects that can cause damage to the system are present 14 The inverter is the only power source to the motor Getting Started, , A5E A AB 29

30

31 Commissioning 6 Commissioning the Inverter The STARTER software uses a series of wizards and masks to guide the user through the commissioning procedures for the inverter. What do you need? The following items are required to commission the Inverter with STARTER: The PC connection cable - order number: 3RK1922-2BP00 STARTER software installed on your PC - order number: 6SL3072-0AA0-0AG0 Note PC connection cable 3RK1922-2BP00 Version E02 or higher of the PC connection cable should be used with the SINAMICS G120 D Control Unit. Commissioning procedure CAUTION Commissioning - Motor Potentiometer Function The default command source for the SINAMICS G120D Inverter is the Fieldbus. If the Fieldbus is not required and the command source is changed to the digital inputs (P0700 = 2) then the following parameters must be changed: P1035 = 0 Disables the Motor Potentiometer Up function P1036 = 0 Disables the Motor Potentiometer Down function or Select other valid command sources, for example: P0705 = 13 Motor Potentiometer Up using DIN4 P0706 = 14 Motor Potentiometer Down using DIN5 If these changes are not performed, then the Motor Potentiometer function will cause a F0070 fault to be generated. Once STARTER is running it will present the first wizard which will allow hardware to be configured, such as CU type, PM type etc. This is shown in the figure below. Getting Started, , A5E A AB 31

32 Commissioning Figure 6-1 STARTER - start-up wizard. Once a project has been created, the configuration of the inverter and its commissioning is accomplish by clicking on "Device configuration" in the "Drive Navigator" mask, as shown in the figure below. Figure 6-2 STARTER - Drive configuration On completion of the commissioning process the data can be transferred to the Inverter memory. 32 Getting Started, , A5E A AB

33 Commissioning Brake module If a brake module is fitted to the motor, it can be configured by using the Brake Module mask. This can be selected by using the project tree on the left-hand side of the screen. See figure below. Figure 6-3 STARTER - Brake control mask Getting Started, , A5E A AB 33

34 Commissioning Temperature sensors If a KTY or PTC temperature sensor is fitted to the motor, it can be configured by using the Temperature sensor mask. The sensor mask may be selected by using the project tree on the left-hand side of the screen. See figure below. Figure 6-4 STARTER - Temperature sensor mask 34 Getting Started, , A5E A AB

35 Commissioning Expert list There may be a requirement for some specific parameters to be modified that do not appear in various wizards and masks. These parameters can be accessed using the "Expert List" mode within STARTER. The expert list mode is selected by right-clicking on the required device in the project as shown in the figure below. Figure 6-5 STARTER - Expert list selection Once the expert list mode has been selected, all parameters available for the installed Inverter are presented. See figure below. In this mode, any parameter can be modified directly on-screen. Figure 6-6 STARTER - Expert list screen Getting Started, , A5E A AB 35

36 Commissioning 6.1 Commissioning the application Commissioning the applications The following information is provided to allow a simple conveyor application to be setup. The logic and control mechanism is provided by a PLC. The conveyor section consists of three sensors: A: This sensor detects the arrival of an item on the conveyor. B: This sensor detects the item and signals the next section to start and be ready to receive an item. This requires two speeds, one for the normal movement of the load and a faster speed for the transfer between conveyor sections. C: This sensor detects the load leaving the conveyor section. The sensors are directly connected to the Inverter to allow their individual status to be sent to the controlling PLC. 36 Getting Started, , A5E A AB

37 Commissioning Figure 6-7 Conveyor application 1 direction - 2 speeds Application parameters Using the "Expert List" mode in STARTER (as previously described) the following parameters should be modified as shown in the table below. Before setting the parameters listed below, you must wait until P3900 = 0. Getting Started, , A5E A AB 37

38 Commissioning Table 6-1 Conveyor application parameters Parameter Setting Description P0701 [0] 99 Digital input DI0 set to BiCo allowing status to be read by PLC P0703 [0] 99 Digital input DI2 set to BiCo allowing status to be read by PLC P0705 [0] 99 Digital input DI4 set to BiCo allowing status to be read by PLC P Sets communication board PZD telegram to "Free BiCo" P2051 [2] Maps state of digital inputs to PZD word 3 (= index 2) P2051 [3] Maps error number to PZD word 4 (= index 3) Example S7 script and ladder logic The following is an example S7 script which the PLC will use to communicate with the Inverter. //============================================================================== L PEW 256 T MW 10 // -> ZSW 1 L PEW 258 T MW 12 // -> actual frequency L PEW 260 T MW 14 // -> status digital inputs L PEW 262 T MW 16 // -> actual error number //============================================================================== L W#16#47E T MW 20 U E 0.0 // Start / stop drive = M 21.0 U E 0.1 // Reverse = M 20.3 U E 0.2 // Error ACK = M 21.7 L MW 20 T PAW 256 // <- STW 1 L W#16#4000 // 4000 hex = 100% (2000 hex = 50%) T PAW 258 // <- frequency setpoint //============================================================================== Figure 6-8 Example S7 script The following is an example ladder logic diagram 38 Getting Started, , A5E A AB

39 Commissioning Figure 6-9 S7 Ladder logic example Getting Started, , A5E A AB 39

40

41 Factory Reset 7 Description With a factory reset a defined initial state of all of the inverter parameters can be reestablished. To perform a factory reset with STARTER, the inverter must be in the online mode. If it is offline, perform "connect to target system" ( ) The factory reset is performed in the following steps: Select the drive unit in the navigation tree ( ) Click the factory reset icon ( ). Note When resetting the parameters to the factory setting, the communications memory is reinitialized. This means that communications are interrupted for the time it takes to perform the reset. Getting Started, , A5E A AB 41

42

43 Diagnostics A Fault codes The inverter has the capability to identify internal and external fault conditions, the most common faults are shown in the following tables. More detailed information on faults can be found in the Parameter List. Table A- 1 Fault codes description Fault Number Meaning F00001 Cause Remedy F00002 Cause Remedy F00003 Cause Remedy F00004 Cause Remedy F00041 Cause Remedy F00052 Cause Remedy F00062 Cause Remedy F00070 Cause Remedy F00071 Cause Remedy F00072 Cause Remedy F00090 Cause Remedy F0395 Cause Remedy Overcurrent - Motor power does not correspond to the inverter power Check that the motor and inverter power ratings are the same. Overvoltage - mains supply voltage too high or motor is in regenerative mode. Check the mains supply voltage Undervoltage - mains supply has failed Check mains supply Inverter over temperature - the inverter has exceeded the temperature limits Check motor loading, pulse frequency setting, ambient temperature or if fitted the fan is working correctly. Motor data identification failure check that the motor is connected to the inverter correctly and that the motor data entered is correct. Power stack failure Check the connections between the CU and PM. MMC contents invalid Recopy data to MMC and ensure that the process is completed. PLC setpoint fault Check the value of P2040 and ensure it is correct USS setpoint fault Check and improve monitoring timing using STARTER USS setpoint fault Check USS master Encoder feedback loss Check that the encoder is installed and commissioned correctly. The fault occurs after a CU/PM swap or startup clone. It can also be cause by a faulty read from the EEPROM. On safety units it is necessary to do an acceptance test. On standard units the current parameter set needs to be checked and confirmed by clearing the fault or setting P7844 = 0. Getting Started, , A5E A AB 43

44 Diagnostics LED description The Inverter, depending upon the variant, has a number of LEDs which are used to indicate the state of the Inverter. This is shown in the figure below. Figure A-1 SINAMICS G120 D LEDs 44 Getting Started, , A5E A AB

45

46 Siemens AG Automation and Drives Standard Drives Postfach Erlangen Deutschland

SINAMICS. SINAMICS G120 Control Units CU240S CU240S DP CU240S DP-F CU240S PN. Getting Started. Warnings and Cautions 1. Installation 2.

SINAMICS. SINAMICS G120 Control Units CU240S CU240S DP CU240S DP-F CU240S PN. Getting Started. Warnings and Cautions 1. Installation 2. Warnings and Cautions 1 Installation 2 SINAMICS SINAMICS G120 Control Units CU240S CU240S DP CU240S DP-F CU240S PN Check List 3 Commissioning 4 Diagnostics A Getting Started Valid for firmware version

More information

Getting Started 10/2008 A5E B AC. SINAMICS G120 Control Units CU240S FW 3.2. Additional Documentation Support 1. Warnings and Cautions 2

Getting Started 10/2008 A5E B AC. SINAMICS G120 Control Units CU240S FW 3.2. Additional Documentation Support 1. Warnings and Cautions 2 Additional Documentation Support 1 SINAMICS G120 Warnings and Cautions 2 Installation 3 Check List 4 Commissioning 5 Technical data 6 Getting Started Diagnostics A FW 3.2 10/2008 A5E01301803B AC Legal

More information

SINAMICS G110D. Inverter. Getting Started Guide May 2009 SINAMICS

SINAMICS G110D. Inverter. Getting Started Guide May 2009 SINAMICS Inverter Getting Started Guide May 2009 SINAMICS Manual Collection and Online Document Support 1 Warnings and Cautions 2 SINAMICS Getting Started Mechanical Installation 3 Electrical Installation 4 Check

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

Siemens Industrial s

Siemens Industrial s SINAMICS G130 Operating Instructions 05/2010 SINAMICS Siemens Industrial s Sinusoidal filter Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS SINAMICS G130 Operating Instructions 05/2010 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Operating Instructions Edition 10/2008

Operating Instructions Edition 10/2008 Operating Instructions Edition 10/2008 Control Units CU240D DP 3.2 CU240D DP-F 3.2 CU240D PN 3.2 CU240D PN-F 3.2 Firmware version 3.2 SINAMICS G120 D s Safety notes 1 Description 2 SINAMICS SINAMICS G120D

More information

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting. Device manual SINAMICS SINAMICS G120 Control cabinet for wall or floor mounting Edition 06/2018 www.siemens.com/drives Safety note 1 Description 2 SINAMICS SINAMICS G120 Manual Mounting 3 Connection 4

More information

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS SINAMICS G130 Operating instructions 03/2011 SINAMICS s Safety information 1 General 2 SINAMICS SINAMICS G130 Voltage Sensing Module 10 (VSM10) Mechanical installation 3 Electrical installation 4 Technical

More information

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.7 04/2014 A5E00331462A Legal

More information

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS SINAMICS G130 Operating Instructions 03/2013 SINAMICS s Safety information 1 General information 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 04/2007 A5E01119980-01

More information

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3 Getting Started - Startdrive Introduction 1 Connecting the drive unit to the PC 2 Startdrive SINAMICS Getting Started Creating a project 3 Going online and incorporating devices 4 Commissioning the drive

More information

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0) SIMATIC ET 200S distributed I/O SIMATIC Preface ET 200S distributed I/O Digital electronic module 2DO AC24..230V (6ES7132-4FB01-0AB0) Properties 1 Parameters 2 Diagnostics 3 Manual 04/2007 A5E01077264-01

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01

More information

Siemens Drives & PLCs

Siemens Drives & PLCs Automation System S7-300: Getting Started CPU 31xC: Commissioning Introduction 1 Preparation 2 SIMATIC S7-300 Automation System S7-300: Getting Started CPU 31xC: Commissioning Learning units 3 Further

More information

Operating Instructions Edition 10/2007

Operating Instructions Edition 10/2007 Operating Instructions Edition 10/2007 Control Units CU240E sinamics G120 s Introduction 1 Safety notes 2 SINAMICS G120 Operating Instructions Description 3 Installing/Mounting 4 Commissioning 5 Communication

More information

SINAMICS G120. Power Module PM250. Hardware Installation Manual 07/2009 SINAMICS. Answers for industry.

SINAMICS G120. Power Module PM250. Hardware Installation Manual 07/2009 SINAMICS. Answers for industry. SINAMICS G120 Hardware Installation Manual 07/2009 SINAMICS Answers for industry. Introduction 1 Safety notes 2 SINAMICS SINAMICS G120 Hardware Installation Manual Installing/Mounting 3 Connecting 4 Service

More information

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL. Product Information Mixed Configuration ET 200SP / ET 200AL SIMATIC ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL Product Information Preface Application planning 1 Mounting 2 Connection

More information

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P dv/dt filter plus Voltage Peak Limiter Operating Instructions Mechanical installation 3 Electrical installation 4 Maintenance and servicing 5 Technical

More information

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information SIMATIC Digital Input Module Product information 1 SIMATIC Digital Input Module Product Information This documentation is part of the documentation package with the order number: S7-300 Automation System:

More information

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties. Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual 06/2010

More information

SINAMICS G120D SINAMICS CU250D-2. Power Modules: SINAMICS PM250D. Getting Started Guide 01/2013 SINAMICS. Answers for industry.

SINAMICS G120D SINAMICS CU250D-2. Power Modules: SINAMICS PM250D. Getting Started Guide 01/2013 SINAMICS. Answers for industry. SINAMICS G120D Control Units: SINAMICS CU240D-2 SINAMICS CU250D-2 Power Modules: SINAMICS PM250D Getting Started Guide 01/2013 SINAMICS Answers for industry. Converter with Control Units CU240D-2 CU250D-2

More information

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3 Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Power module PM-E DC24..48V/AC24..230V (6ES7138-4CB11-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 04/2007

More information

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken. Preface SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A AC24..230V/5A (6ES7132-4HB50-0AB0) SIMATIC ET 200S distributed I/O Digital electronic module 2RO NO/NC DC24..48V/5A

More information

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E SIMATIC S7-300 Getting Started for First Time Users Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E01094750-01 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2. SIMATIC ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01- SIMATIC Preface Properties 1 Diagnostics 2 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A

More information

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties. Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) SIMATIC ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface Properties 1 Parameters 2 Diagnostics 3 Configuring 4 Manual

More information

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode Global FW Rulesets SIMATIC NET Industrial Ethernet Security Preface 1 Firewall in standard mode 2 Firewall in advanced mode 3 Configuring a VPN tunnel 4 Configuring remote access via a VPN tunnel 5 Getting

More information

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

Converter SINAMICS G150. Type 6SL37102G

Converter SINAMICS G150. Type 6SL37102G Tests carried out on drives This documentation pertains to LV Umrichter E11 F72 F76 F79 L45 L50 L57 L68 M54 U11 Reference Manual Converter SINAMICS G150 Type 6SL37102G Edition 02/2019 www.siemens.com/drives

More information

SINAMICS G120. PM250 Power Module. Hardware Installation Manual 09/2012 SINAMICS. Answers for industry.

SINAMICS G120. PM250 Power Module. Hardware Installation Manual 09/2012 SINAMICS. Answers for industry. SINAMICS G120 Hardware Installation Manual 09/2012 SINAMICS Answers for industry. Introduction 1 Safety instructions 2 SINAMICS SINAMICS G120 Hardware Installation Manual Installing/Mounting 3 Connecting

More information

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3. Preface 1 Properties 2 SIMATIC Diagnostics 3 ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02- Manual 01/2008 A5E01254028-01 Safety Guidelines This manual contains notices

More information

Hardware Installation Manual Edition 11/2006. Power Module PM250 SINAMICS

Hardware Installation Manual Edition 11/2006. Power Module PM250 SINAMICS Hardware Installation Manual Edition 11/2006 Power Module PM250 SINAMICS G120 s Introduction 1 Safety notes 2 SINAMICS SINAMICS G120 Hardware Installation Manual Description 3 Installing/Mounting 4 Operation

More information

SINAMICS IOP. Intelligent Operator Panel. Operating Instructions February 2009 SINAMICS

SINAMICS IOP. Intelligent Operator Panel. Operating Instructions February 2009 SINAMICS SINAMICS IOP Intelligent Operator Panel Operating Instructions February 2009 SINAMICS Safety notes 1 Overview 2 SINAMICS SINAMICS Operating Instructions Installation 3 Wizards 4 Control 5 Menu 6 Options

More information

Mechanical Installation Manual SINUMERIK. SINUMERIK 808D Mechanical Installation Manual. Preface. Safety instructions 1. Identification 2.

Mechanical Installation Manual SINUMERIK. SINUMERIK 808D Mechanical Installation Manual. Preface. Safety instructions 1. Identification 2. Preface Safety instructions 1 SINUMERIK SINUMERIK 808D Operating Instructions Identification 2 Mounting 3 Technical data 4 A Appendix Valid for: SINUMERIK 808D Turning (software version: V4.4.2) SINUMERIK

More information

Operating Instructions Edition 10/2007

Operating Instructions Edition 10/2007 Operating Instructions Edition 10/2007 Control Unit CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F Firmware version 3.1 SINAMICS G120 s Introduction 1 Safety notes 2 SINAMICS G120 Operating Instructions

More information

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G130 Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.8 07/2016 A5E00331460A Legal

More information

ST (6ES7132-6FD00-0BB1)

ST (6ES7132-6FD00-0BB1) SIMATIC ET 200SP Digital output module DQ 4x24..230VAC/2A ST (6ES7132-6FD00-0BB1) Manual Edition 02/2014 Answers for industry. DQ 4x24..230VAC/2A ST Preface Guide to documentation 1 SIMATIC ET 200SP DQ

More information

SINAMICS G120 SINAMICS G120D SIMATIC ET 200S FC SIMATIC ET 200pro FC. Product Information. Edition 06/2007. All inverters. Fail-safe inverters

SINAMICS G120 SINAMICS G120D SIMATIC ET 200S FC SIMATIC ET 200pro FC. Product Information. Edition 06/2007. All inverters. Fail-safe inverters s Product Information SINAMICS G120 SINAMICS G120D SIMATIC ET 200S FC SIMATIC ET 200pro FC Edition 062007 This product information sheet describes the behavior of the above mentioned inverters (Firmware

More information

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation SIMATIC NET PG/PC - Industrial Ethernet Operating Instructions 1 Preface 2 Description of the device 3 Software installation 4 Hardware installation 5 Configuration 6 Technical specifications A Approvals

More information

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional Setting up security in STEP 7 Professional SIMATIC NET Industrial Ethernet Security Setting up security in STEP 7 Professional Preface 1 User interface and menu commands 2 Basic configuration 3 Firewall

More information

CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F

CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F SINAMICS G120 Control Units CU240E CU240S CU240S DP CU240S DP-F CU240S PN CU240S PN-F Operating Instructions 11/2008 - Review Version SINAMICS Introduction 1 Description 2 SINAMICS G120 Control Units

More information

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview.

IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC. ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Preface. Documentation guide. Product overview. IO-Link Master (6ES7147-4JD00-0AB0) SIMATIC ET 200pro IO-Link Master (6ES7147-4JD00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address space 4 Diagnostics alarms

More information

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) SIMATIC ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Connecting 3 Parameter

More information

Readme SiVArc V14 SP1 Update 6

Readme SiVArc V14 SP1 Update 6 Product version 1 Improvements in Update 6 2 Readme 05/2018 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as

More information

SINAMICS G120. CU230P-2 Control Units. Operating Instructions Edition 03/2009 FW 4.2 SINAMICS. Answers for industry.

SINAMICS G120. CU230P-2 Control Units. Operating Instructions Edition 03/2009 FW 4.2 SINAMICS. Answers for industry. SINAMICS G120 CU230P-2 Control Units Operating Instructions Edition 03/2009 FW 4.2 SINAMICS Answers for industry. Introduction 1 Safety instructions 2 SINAMICS G120 Control Units Operating Instructions

More information

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76 Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76 Reference Manual Medium-Voltage Drive SINAMICS SM150 Type 6SL3845 Edition 02/2019 www.siemens.com/drives

More information

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010 SINAMICS G120 Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F Function Manual Safety Integrated 07/2010 SINAMICS Answers for industry. Safety Integrated Function Manual,

More information

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of Inter Project Engineering Team engineering via Inter Project Engineering TIA Portal Basics of "Inter Project Engineering" 1 Creating an IPE file 2 Importing an IPE file 3 Team engineering via Inter Project Engineering Getting Started

More information

SINAMICS G120P. Power Module PM230 IP55/UL Type 12. Hardware Installation Manual 07/2010 SINAMICS. Answers for industry.

SINAMICS G120P. Power Module PM230 IP55/UL Type 12. Hardware Installation Manual 07/2010 SINAMICS. Answers for industry. SINAMICS G120P /UL Type 12 Hardware Installation Manual 07/2010 SINAMICS Answers for industry. Introduction 1 Safety notes 2 SINAMICS G120P SINAMICS Hardware Installation Manual Installing/Mounting 3

More information

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction Fundamental safety instructions 1 Introduction 2 SIMATIC/SINAMICS Getting started with SINAMICS V90 PN on S7-1500 Motion Control Getting Started Prepare the configuration 3 Create a project 4 Creating

More information

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions SIMATIC Ident RFID systems Compact Operating Instructions Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to

More information

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations

Industrial Controls. Motor management and control devices SIMOCODE pro. Introduction 1. Configuring a reversing starter. List of abbreviations Introduction 1 Configuring a reversing starter 2 Industrial Controls A List of abbreviations Motor management and control devices Getting Started 05/2018 A5E40507294002A/RS-AB/002 Legal information Warning

More information

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 Analog value representation

More information

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface

Digital input module. DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC. ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Preface Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) SIMATIC ET 200AL Digital input module DI 16x24VDC 8xM12 6ES7141-5AH00-0BA0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters/address

More information

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618 1 SIMATIC Sensors RF systems Wide-range power supply unit for SIMATIC RF systems Operating Instructions 11/2007 J31069-D0169-U001-A4-7618 Safety Guidelines This manual contains notices you have to observe

More information

Siemens Automation Products

Siemens Automation Products Introduction 1 Configuring the hardware in the offline mode 2 Startdrive Startdrive Getting Started SINAMICS S120 in Startdrive Getting Started Connecting the drive unit with the PC and going online 3

More information

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC First Steps in Commissioning CPU 31xC: Positioning with digital output Introduction 1 Preparation 2 SIMATIC S7-300 First Steps in Commissioning CPU 31xC: Positioning with digital output Learning units

More information

SINAMICS G120D converter with control units CU240D-2 and CU250D-2 SINAMICS

SINAMICS G120D converter with control units CU240D-2 and CU250D-2 SINAMICS SINAMICS G120D converter with control units CU240D-2 and CU250D-2 SINAMICS SINAMICS G120D SINAMICS G120D converter with control units CU240D-2 and CU250D-2 Getting Started Fundamental safety instructions

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2 BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC ET 200SP BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) Manual Preface Guide to the documentation 1 Product overview 2 BaseUnits for I/O modules 3 BaseUnits

More information

Operating Instructions 11/2007

Operating Instructions 11/2007 Operating Instructions 11/2007 OPERATING INSTRUCTIONS simatic s Product Information SIMATIC ET 200S FC SIMATIC Edition 11/2007 This product information sheet describes the behavior of the above mentioned

More information

Drive System Application

Drive System Application Drive System Application Commissioning of the Control Unit CU230P-2 DP with PROFIBUS Application description for SINAMICS G120 and MICROMASTER 440 Warranty, liability and support Note The Application Examples

More information

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E SIMATIC Communications processor Getting Started 09/2008 A5E02291899-01 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety,

More information

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0) 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- SIMATIC Preface 1 Properties 2 Diagnostics 3 ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32- Manual 10/2015

More information

SINAMICS G120. Frequency inverters with the Control Units CU230P-2 CU240B-2 CU240E-2. Getting Started 03/2012 SINAMICS. Answers for industry.

SINAMICS G120. Frequency inverters with the Control Units CU230P-2 CU240B-2 CU240E-2. Getting Started 03/2012 SINAMICS. Answers for industry. SINAMICS G120 Frequency inverters with the Control Units CU230P-2 CU240B-2 CU240E-2 Getting Started 03/2012 SINAMICS Answers for industry. Frequency converters with Control Units CU230P-2; CU240B-2; CU240E-2

More information

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1] Loading the block library 1 Deleting program block Main [OB1] 2 TIA Portal SIMATIC Getting Started Copying program blocks 3 Copying tag tables 4 Compiling a project 5 Load project into the CPU 6 03/2013

More information

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618 English SIMATIC Sensors RFID-Systems Getting Started Edition 11/2005; J31069-D0172-U001-A1-7618 Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual Class documentation COMOSKDictionary COMOS Trademarks 1 General 2 KDictionary 3 Platform Class documentation COMOSKDictionary Programming Manual 04/2012 A5E03777026-01 Legal information Legal information

More information

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information SIMATIC Automation Tool features 1 Known problems 2 SIMATIC S7/HMI SIMATIC Automation Tool V3.1 SP1 product information Product Information V3.1 SP1, 05/2018 A5E43714043-AA Legal information Warning notice

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2. SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Manual Preface 4 IQ-SENSE module (6ES7138-4GA00-0AB0) 1 Parameters 2 Diagnostics 3 Control interface

More information

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1 SIMATIC Process Control System PCS 7 SIMATIC Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1 Commissioning Manual Preface 1 Before beginning the software

More information

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4 Preface 1 Scope of Delivery 2 Product Characteristics 3 Industrial I/O-Node ION PROFIBUS DP SPY T001 Installation and Maintenance 4 6AT8000-1BA00-5XA0 Notes on the CE Mark 5 References 6 Appendix 7 Release

More information

SINAMICS G120. Inverters with the Control Units CU230P-2 CU240B-2 CU240E-2. Getting Started SINAMICS. Answers for industry.

SINAMICS G120. Inverters with the Control Units CU230P-2 CU240B-2 CU240E-2. Getting Started SINAMICS. Answers for industry. SINAMICS G120 Inverters with the Control Units CU230P-2 CU240B-2 CU240E-2 Getting Started 06 2010 SINAMICS Answers for industry. CU230P-2; CU240B-2; CU240E-2 Control Units Design and installation 1 Commissioning

More information

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme Validity 1 Improvements in STEP 7 2 SIMATIC Improvements in WinCC 3 05/2017 Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety,

More information

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters

More information

SINAMICS Siemens Controlss

SINAMICS Siemens Controlss SINAMICS G150 / S150 / S120 Cabinet Modules / G130 Operating Instructions 10/2008 SINAMICS Siemens Controlss Preface Introduction 1 SINAMICS G150 / S150 / S120 Cabinet Modules / G130 Operating Instructions

More information

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2

SIMATIC. Function modules FM 351 First Steps in Commissioning. Purpose of the Getting Started. Requirements 2 Purpose of the Getting Started 1 Requirements 2 SIMATIC Function modules FM 351 First Steps in Commissioning Getting Started Installing the configuration package on the PG 3 FM 351, installing and wiring

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1 Options for Accessing Documentation 1 Notes on the Product Documentation 2 SIMATIC Notes on the PCS 7 V8.0 SP2 system documentation 3 Process Control System PCS 7 PCS 7 system documentation - Readme V8.0

More information

Intelligent Operator Panel (IOP)

Intelligent Operator Panel (IOP) Safety notes 1 Overview 2 SINAMICS SINAMICS G110D, SINAMICS G110M, SINAMICS G120, SINAMICS G120C, SINAMICS G120D Operating Instructions Installation 3 Wizards 4 Control 5 Menu 6 Options 7 Technical data

More information

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH

PROFIenergy product information SIMATIC. ET 200SP PROFIenergy product information. PROFIenergy 1. Product Information 12/2015 A5E AH PROFIenergy 1 SIMATIC ET 200SP Product Information 12/2015 A5E03871936-AH Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety,

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example Introduction 1 Application example 2 Industrial Controls Motor management and control devices SIMOCODE pro - Application examples Application Manual Example circuits control functions 3 Further application

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions Introduction 1 Installing/Mounting 2 SITRANS F Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel Hardware Installation Instructions 1/2010 A5E02518333A Revision 04 Legal information Warning notice

More information

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description

PSR-MS60. Safety relay for emergency stop, safety door and light grid monitoring. Data sheet. 1 Description SILCL IEC 62061 Safety relay for emergency stop, safety door and light grid monitoring Data sheet 106171_en_01 PHOENIX CONTACT 2015-05-19 1 Description Intended Use The PSR-MS60 safety relay can be used

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information.

Industrial Controls. SIMOCODE pro SIMOCODE pro PCS 7 Library. Preface. Security information. Product specific security. information. Industrial Controls SIMOCODE pro Preface 1 Product specific security Security information 2 information 3 Introduction 4 5 References 6 List of Abbreviations 7 10/2018 A5E36558134002A/RS-AB/002 Legal information

More information

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact Characteristics variable speed drive ATV320-0.37kW - 380...500V - 3 phase - compact Main Range of product Product or component type Product specific application Device short name Format of the drive Product

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Characteristics variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink Main Range of product Altivar 32 Product or component type Product destination Product specific application

More information

SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4

SIMATIC. Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS S120. Introduction. Preparation 2. Learning units 3. Further Information 4 SIMATIC Programmable Logic Controllers S7 300 SIMATIC Programmable Logic Controllers S7 300 CPU 317T-2 DP: Controlling a SINAMICS S120 SIMATIC Automation Systems S7-300 CPU 317T-2 DP: Controlling a SINAMICS

More information

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730.

Performance data abgn SCALANCE W770/W730 SIMATIC NET. Industrial Wireless LAN Performance data abgn SCALANCE W770/W730. Performance data 802.11 abgn SCALANCE W770/W730 Technical data 1 SIMATIC NET Industrial Wireless LAN Performance data 802.11 abgn SCALANCE W770/W730 Reference Manual 07/2014 C79000-G8976-C370-01 Legal

More information