Rapidus Power Factor Controller
|
|
- Bennett Rose
- 5 years ago
- Views:
Transcription
1 Rapidus Power Factor Controller
2 Moduler design No connector cables No fixing screws State of the art technology Easy mounting on panels connection to system
3 Dynamic Capacitor Monitoring DCM is a supreme function in Rapidus which enables the user to make proactive maintenance for compensation cabinets. DCM tracks the real time KVAR values of each capacitor and uses the measured KVAR value in compensation calculations. If a contactor is broken or a capacitor is out of order, DCM will detect it within or days and activate the alarm for user. DCM has 3,4% accuracy. This information is valid for 3 shift operating facilities. Initial Values Alarm Level Setup Contactors C C C3 C4 Alarm Level %0 5 kvar 0 kvar 0 kvar 0 kvar After a certain time Alarm screen indicates the status of 3rd and 4rd steps MOBDUS RS 485 Remotely monitor actual kvar values of each step in addition to DCM alarms Pro active maintenance Highly sensitive compensation due to realtime kvar measurements of the steps Contactors C C C3 C4 Alarm Level %0 3 kvar 3 kvar kvar 0 kvar Means capacitor should be changed Means capacitor is out of order or contactor is out of order or cable connection problem or fuse blown
4 Capacitor/ReactorP/3P Rapidus can be connected to either single or three phase capacitors or reactors. Rapidus can be used in Data Centers or Mining Areas where the load is frequently capacitive. Rapidus can be used with a selection of capacitors and reactors in single or three phase connections. Mono Phase 3 Phase Reactor Phase Reactor 3 Phase Capacitor Capacitor 3 Phase Capacitor Fig. A Fig. B V V V3 N V V V3 N Advanced Learning Function L3 K3 L K L K V V V3 N K3 L3 L K K L V V3 V N Rapidus can learn the connections and capacitor or reactor values. If there is a fault in the CT or VT connections, Rapidus detects the fault and corrects it. It shows the fault on the screen. Correct connection Wrong connection Advanced Learning Function Rapidus detects the wrong connections after learning mode is activated. Connections are displayed on the screen. Rapidus don't take misconnections into consideration and operates as if all connections are properly made as shown in Fig A. Rapidus learns all step values regardless they are capacitor or reactor.
5 Rapidus = PFC + Energy Analyzer In standart compensation cabinets, there are always a multimeter or analyzer to be associated with a power factor controller. Rapidus, as a twoinone device meets both requirements of the industry. User can reduce the cost of analyzer, wiring and labor by choosing Rapidus. Saving On Extra multimeter / analyzer cost Wiring cost Labor cost Rapidus as an Energy Analyzer Rapidus can measure and monitor the following parameters : All electrical parameters Min, Max and Average Values for Hour, Day and Month Harmonics upto 5 st Demand Phasor Diagram Data Logging Rapidus measures Rapidus logs Rapidus logs Rapidus logs MB Memory 68 different energy parameters. 80 days hourly 40 days daily 36 months monthly real time measurements of 68 parameters. demand values for P. Q, S, I 50 recent alarms with time stamp.
6 Surge Withstand 00 A/ sec Rapidus current inputs can withstand surges upto 00 A for second. In case of a current rise in the secondary winding of the current transformer, current inputs of the PFC should withstand to these peak values. If not, current transformer may explode due to open circuit in the secondary winding. This may result with shutdown of the compensation system and compensation penalty for the enduser. 5 A 00 A sec. Accuracy Class (0,s) Function Symbol Function Function Performance Class According to IEC 6557 Measuring Range Other Complementary Characteristics P Total active power 0, 0 % I b 0,5 Ind to 0,8 Cap Q V Total reactive power 5 % I b 0,5 Ind to 0,5 Cap S A Total apparent power 0, 0 % I b 0,5 Ind to 0,8 Cap E A Total active energy 0, 0 to IEC 6053 Class S E RV Total reactive energy 0 to IEC Class f Frequency 0, Hz I Phase current 0, 0 % I b I Nc Neutral current 0,5 0 % I b U Voltage 0, U min U U max P FA Power factor 0,5 0,5 Ind to 0,8 Cap THDV Total harmonic distortion voltage 0 % to 0 % THDI Total harmonic distortion current 0 % to 00 % Other Features Graphical LCD Language Support Harmonics Measurement upto 5 Advanced Alarm Settings Real Time Clock
7 Rapidus Product Selection Chart General Graphical LCD 6 buttons Password Protection Measurement Type Supply Voltage AC Supply Voltage DC Day/Night Input Number of Steps Current Transformer Ratio Voltage Transformer Ratio Connection Type Type of Switching Target cosq Accuracy Class Voltage Accuracy Class Current Accuracy Class Active Energy Number of Measurement in a period Power Consumption Power Quality Measurements Harmonics / current and voltage THDVoltage in % THDCurrent in % Phasor Diagram Data Logging Average, Minimum, Maximum Values Alarms Time Stamp Voltage Measurement Input (Supply and Measurement Inputs are the same node) Overvoltage Category Measured Range LN Measured Range LL Measured Frequency Range Power Consumption Sampling Freq.between 4565 Hz Current Measurement Input Rated Current Measurement Range Overvoltage Category Measurement Surge Voltage Power Consumption Peak current for sec Sampling Freq.between 4565 Hz Input Outputs Outputs Max. Switching Current Max. Switching Voltage Max. Switching Power for a Single Alarm Outputs Max. Switching Current Max. Switching Voltage Max. Switching Power GEN Input Input range Mechanical Properties Weight Protection Class Assembly Type Dimensions Cable Cross Sections Voltage, Current, All Outputs, Gen Input Stranded: Solid: RAPIDUS 3RE 3 Phase 8565 V AC Selectable 0,80,00 Inductive or Capacitive 5 < 0VA Upto 5st I 957 Vrms Vrms 4565 Hz <0. VA 0.0 kv < VA 00 A A 50 VA 000 VA VAC 0,670 kg IP 40 front, IP 0 rear W44xH44xD78,5 mm 4AWG 4mm AWG x.5 mm x6 AWG RAPIDUS 3RE 3 Phase 8565 V AC 4 Selectable 0,80,00 Inductive or Capacitive 5 < 0VA Upto 5st I 957 Vrms Vrms 4565 Hz <0. VA 0.0 kv < VA 00 A 4 A 50 VA 000 VA VAC 0,765 kg IP 40 front, IP 0 rear W44xH44xD78,5 mm 4AWG 4mm AWG x.5 mm x6 AWG 6060 RAPIDUS R Phase 8565 V AC Selectable 0,80,00 Inductive or Capacitive 5 < 0VA Upto 5st I 957 Vrms Vrms 4565 Hz <0. VA 0.0 kv < VA 00 A A 50 VA 000 VA VAC 0,653 kg IP 40 front, IP 0 rear W44xH44xD78,5 mm 4AWG 4mm AWG x.5 mm x6 AWG RAPIDUS R Phase 8565 V AC 4 Selectable 0,80,00 Inductive or Capacitive 5 < 0VA Upto 5st I 957 Vrms Vrms 4565 Hz <0. VA 0.0 kv < VA 00 A 4 A 50 VA 000 VA VAC 0,750 kg IP 40 front, IP 0 rear W44xH44xD78,5 mm 4AWG 4mm AWG x.5 mm x6 AWG RAPIDUS 8R Phase 8565 V AC 8 Selectable 0,80,00 Inductive or Capacitive 5 < 0VA Upto 5st I 957 Vrms Vrms 4565 Hz <0. VA 0.0 kv < VA 00 A 8 A 50 VA 000 VA VAC 0,45 kg IP 40 front, IP 0 rear W96xH96xD7,5 mm 4AWG 4mm AWG x.5 mm x6 AWG RS 485 Stranded: Solid: Ambient Conditions Operating Temperature Storage Temperature Relative Humidity (no condensation) Communication and Others Modbus RTU Battery Real Time Clock Standarts in Compliance Safety requirements for electrical equipment for measurement, control, and laboratory use,5 mm WG.5 mm 6 AWG x0.75 mm x8 AWG 0 C. +60 C.. 30 C. +80 C VAC CAT III acc. to IEC 600,5 mm WG.5 mm 6 AWG x0.75 mm x8 AWG 0 C. +60 C.. 30 C. +80 C VAC CAT III acc. to IEC 600,5 mm WG.5 mm 6 AWG x0.75 mm x8 AWG 0 C. +60 C.. 30 C. +80 C VAC CAT III acc. to IEC 600,5 mm WG.5 mm 6 AWG x0.75 mm x8 AWG 0 C. +60 C.. 30 C. +80 C VAC CAT III acc. to IEC 600,5 mm WG.5 mm 6 AWG x0.75 mm x8 AWG 0 C. +60 C.. 30 C. +80 C VAC CAT III acc. to IEC 600
8 Dimensions (mm) Wiring Diagrams Gen Input Gen Input Rapidus s (606 0)
Energy Management Solutions
Energy Management Solutions Power Generation and Transmission Facilities You can provide solution in your Power transmission project with Klea Energy Analyser and Systemon Software Shopping Malls and Chain
More informationEnergy Monitoring Solutions
Monitoring Solutions More eff iciency than you expected The Fundamentals Def ining an energy analyzer in simple terms An energy analyzer provides highly accurate measuring for main electrical and Metering
More informationRAPIDUS - POWER FACTOR CORRECTION
RAPIDUS - POWER FACTOR CORRECTION LCD Screen, Turkish/English language options 1MByte memory Operates also as an energy analyzer Tariff meter Fast and easy setup Learns connection and steps automatically
More informationGCR 06, GCR 12. Power factor correction controller. User and service manual
GCR 06, GCR 12 Power factor correction controller User and service manual version 1.6 Czech Republic Czech Republic 1 Content 1. Front control panel and back terminal panel...3 2. Device description...
More informationData Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D
WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low
More informationMIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET
& DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationPower Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser
Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser 4 Target Max. Demand (MD) Load Shed Controller Up to 64 loads may be shed to
More informationMIC-2 Multi-instrument DATA SHEET
Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationDEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S
Multi-instrument 4921210107G Features Measurements All 3-phase AC measurements True RMS Replaces analogue meters Intelligent Suitable for all 3-phase network topologies Replaces transducers Accuracy U,
More informationPFC-10 Power Factor Controller
PFC-10 Power Factor Controller Instruction Manual Ver. 6.0 / 2002 (2-2005 update) Table of Contents Page Subject 3 Starter ion 4-5 Installation Notes 6-7 Terminals Review & Control Wiring 8 Front-panel
More informationTechnical Specifications. Multi Function Meter
Technical Specifications of Multi Function Meter (SPM300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationPower Meter PowerMonitor 500
ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific
More informationDKM-407 DIN RAIL TYPE NETWORK ANALYZER
DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution
More informationMultifuncion Measuring Device 96x96 mm, connection via CT
Viale Borri 231, 21100 Varese Italy Multifuncion Measuring Device Contents Pages 1. Description Use... 2 2. Range... 2 3. Overall dimensions... 2 4. Preparation Connection... 2 5. General characteristics...
More informationRTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values
CT/VT Interface 560CVT10 The fault current is measured up to 20 times nominal current. Therefore the current inputs withstand 50 times nominal current for 1 s. The CT/VT interface is equipped with one
More informationMehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording
Mehta Tech, Inc. TRANSCAN IED For Multi-Function, Multi-Speed Recording Two independent, simultaneously operating recorders in one package Triggering on input quantities and calculated values, such as
More informationPQM - Power Quality Monitoring
UMG 96S PQM - Power Quality Monitoring The little field bus giant Universal flush-mounting measuring instruments of the UMG 96S product family are mainly designed for use in low and medium voltage distribution
More informationPOWER FACTOR REGULATOR
POWER FACTOR REGULATOR Computer Smart 6/Computer Smart 12 Instruction Manual (M98235701-03-12A) - 1 - Table of Contents 1 INTRODUCTION AND SAFETY TIPS...3 1.1 CHECKS TO BE CARRIED OUT WHEN THE REGULATOR
More informationEngyVolt RV12 and RV15
Technical Information EngyVolt RV12 and RV15 Multifunctional electrical energy meters for top-hat rail installation or panel mounting Application For measuring voltage, frequency, current, power, as well
More informationSmart Energy & Power Quality Solutions. UMG 505 Power analysis, LON and I/O-Vielfalt
Smart Energy & Power Quality Solutions UMG 505 Power analysis, LON and I/O-Vielfalt UMG 505 UMG 505 Power analysis, LON and I/O-Vielfalt Power analysers of the UMG505 product family are mainly designed
More informationPF Controllers BR6000 Series
PF Controllers BR6000 Series Intelligent User-friendly Cost-effective Version 5.0 General Controllers for PFC are of major importance in the PFC system. They measure the actual power factor and connect
More informationTechnical Specifications. Dual Source Energy Meter (EB / DG)
Technical Specifications of Dual Source Energy Meter (EB / DG) (SPMG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com
More informationUSER MANUAL 2012 V1.1
SMART MINI POWER SDM630 USER MANUAL 2012 V1.1-1 - Installation and Operation Instructions Important Safety Information is contained in the Maintenance section. Familiarise yourself with this information
More informationPower supply. Interface technology in modular housing DIN rail devices, IM series. Features
Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating
More informationSLI 15 Inverter Series Data Sheet 1500 Watt, 1U Compact Inverters
Applications Telecom IT Industrial Safety in compliance with IEC60950:1999, 3 rd edition; EN60950:2000; UL60950, 3 rd edition; CSA Standard C22.2 No.60950-00, 3 rd edition Features New, compact design:
More informationSmart Energy & Power Quality Solutions. UMG 96S Universal flush-mounting measuring instrument
Smart Energy & Power Quality Solutions UMG 96S Universal flush-mounting measuring instrument UMG 96S UMG 96S Universal flushmounting measuring instrument Universal flush-mounting measuring instruments
More informationPower factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC
Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC 100% ity Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration
More informationAPU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET
APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET Measurement input, auto range Up to 1000 V AC L-L Up to 12.5 A (sinusoidal) 16 400 Hz Output Up to four analogue outputs Relay output RS 485 Modbus
More informationU niversal Measuring Device UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs. Digital I/O
U niversal Measuring Device Little Fieldbus Giant Modbus / Profibus Harmonics Memory Analogue outputs Digital I/O Modem Recorder Profibus Modbus PC I/O Universal Measuring Device Application Application
More informationUMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application
UMG 511 Class A EN 50160 UMG 511 Class A power quality analyzer according to EN50160, IEEE 519, ITIC, IEC 61000-4-30 The UMG 511 power quality analyzer is particularly suitable for monitoring power quality
More informationPowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet
PowerLogic power-monitoring units power meter Technical data sheet 2011 Basic energy meters Functions and characteristics PE86261 PE86260 PowerLogic PM1000 power meter. The PowerLogic power meters are
More informationContact protection relay
Contact protection relay Ordering details SVR 450 08 F0000 The protects sensitive control contacts from excessive load. It can be used with latching function or without. Bounce time of control contacts
More informationMID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID
PRELIMINARY DATA SHEET RI-D35-100 Series Single Phase Multifunction Energy Meter (MID Certified) MID direct connected Two pulse outputs LED pulse indication High definition LCD display with white backlight
More informationNetworks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks
Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus
More informationLSFC Power Factor Correction Systems
LSFC Ready to connect, automatic in sheet steel cabinets for floor installation. Suitable for networks without harmonic distortion. Power Range: 100 to 00 kvar Modular construction in freestanding sheet
More informationEM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters
Power and Energy Meters Code No. LIT-1900845 Issued December 4, 2013 EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters EM-1000 Series Meter Description The EM-1000 Series monitor is
More informationPower and accuracy. Versatile. One display can monitor up to 32 measuring modules information
Power and accuracy 0.2% or 0.5% class in power and active energy measurement Over 500 electric parameters display Both voltage and current harmonics spectrum graphics (to the 50 th ) Maximum and minimum
More informationUMG 96RM. UMG 96RM Universal measurement instrument. Areas of application
UMG 96RM UMG 96RM Universal measurement instrument The UMG 96RM is a very compact and powerful universal measurement device designed for use in low and medium voltage distribution systems. In addition
More informationSLI 15 INVERTER SERIES, 1500 W
SLI 15 INVERTER SERIES, 1500 W FEATURES DESCRIPTION New, compact design: 1U height x 19" width x 14.94" depth; 19" rack-mountable High efficiency: up to 93% True sine wave output Parallelable output with
More informationDKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY
datakom@datakom.com.tr http://www.datakom.com.tr Tel: +9-216 466 84 6 Fax: +9-216 364 65 65 DKM-45 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY INTRODUCTION The DKM-45 is a low cost precision
More informationLEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer
LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY Three LEVEL UPS VFI TYPE PF=.0 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS True Three Level Rectifier and Inverter Technology
More informationREACTIVE ENERGY REGULATORS
REACTIVE ENERGY REGULATORS computer MAX 6f 12Vdc computer MAX 12f 12Vdc Instruction Manual (M066B01-03-15B) - 1 - Table of Contents 1 INTRODUCTION AND SAFETY TIPS... 3 1.1 CHECKS TO BE CARRIED OUT WHEN
More informationDATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface
DATA SHEET For Energy and Power meters AEM and APM with Modbus interface Data logging Web Server interface Gateway - Modbus TCP/IP FTP DynDNS Up to 32 Energy and Power meters DEIF A/S Page 1 of 9 Document
More informationPower Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter
Contents Description Page Product overview.... 2 Key features.... 2 Wide voltage range.... 2 Ordering information... 2 Additional features.... 2 functions comparison... 3 Metering.... 4 Specifications....
More informationCapacitor Switching Contactors
Capacitor Switching Contactors Types K3-..A.. and K3-..K.. Ideal for Power Factor and Harmonic Filter Systems Features that matter Patented design with significant damping of inrush current Long life tested
More informationThree-Phase Power Quality Analyzer PowerPad Model 3945
Three-Phase Power Quality Analyzer PowerPad Model 3945 Wouldn t it be nice if you could look inside your electrical system and see what s going on? Troubleshooting would be so much easier if you could
More informationDigital Multifunction Meters. Digital Multifunction Meters
Digital Multifunction Meters Digital Multifunction Meters DIGITAL MULTIFUNCTIOL METERS SECTION INDEX 1. MFM 3410 3420 3430 3440 6100 & 2000 - Multifunctional Instrument Series 2. EM 3490, 3490SS, 3490DS
More informationPowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006
PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical
More informationU niversal Measuring Device NEW! UMG 96 S. Little Fieldbus Giant. Modbus / Profibus. Harmonics. Memory. Analogue outputs.
U niversal Measuring Device NEW! Little Fieldbus Giant Modbus / Profibus Harmonics Memory Analogue outputs Digital I/O Modem Recorder Profibus Modbus PC I/O Universal Measuring Device Application Application
More informationS1MMmA500VM S1MMmA500VLM S1MMmA500VHM. Technical data. 3-phase energy meter with universal current input
3-phase energy meter with universal current input Equivalent to class 0,5S (KWh) of E6053- Equivalent to class 0,5S (KVARh) of E6053-4 Accuracy ±0,5% RDG Universal input for current measurement Energy
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More informationISOMETER isoev425 with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device
More informationRM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases
Characteristics three-phase control relay 183 528Vac, 2 C/O Main Range of product Product or component type Relay type Network number of phases Relay name Relay monitored parameters Time delay type Switching
More informationDIRIS Digiware D and C Communication and control power interfaces
Multi-circuit metering and measurement diris-dw_006_a_us_cat diris-dw_142_a The solution for > Industry > Building > Infrastructure > Data centers DIRIS D-40/D-50/D-70 Centralization and display of data
More informationPowerPad III Model 8435
Special product features POWER QUALITY ANALYZERS, METERS & LOGGERS Three-Phase Power Quality Analyzer 2GB MEMORY '''' PowerPad III Model CAPT TREND RECORDING RE TRANSIENTS SD card memory capacity for trend
More informationLEVELUPS T3. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability and Robust Protection for Industrial Loads
LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY VFI TYPE PF= 0.9 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS Built In Inverter Transformer for DC-AC Galvanic Protection
More informationLED Driver Compact fixed output
Driver LC 47W 1050mA fixc SC ADV advanced series Product description Fixed output LED Driver Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current LED Driver
More informationAcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:
AcuRev 2000 Multi-Circuit Power and Energy Meter ISO9001 Certified Comply to IEC 62053-21 Measurement Standard Support up to 18 Individual Channels for Energy Measurement Multifunction Power Metering,
More informationMP7. Uninterruptible Power Supply
Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationINTEGRA DIGITAL METERING SYSTEMS
CROMPTON INSTRUMENTS INTEGRA DIGITAL METERING SYSTEMS INTEGRA DIGITAL METERING SYSTEMS The Integra digital metering product portfolio offers an extensive range of systems designed to suit any power monitoring
More informationUMG 605. UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC)
UMG 605 UMG 605 power quality analyzer (EN 50160, IEEE 519, ITIC) The UMG 605 power quality analyzer is particularly suitable for monitoring power quality according to standards such as EN 50160. All power
More informationR E C T I F I E R I N V E R T E R C O N V E R T E R MP7
Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,
More informationLED Driver Compact fixed output
Driver LC 50W 1200mA fixc SC SNC2 ESSENCE series Product description Fixed output LED Driver Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant current LED Driver
More informationISOMETER isoev425/isoev425hc with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles isoev425_d00126_04_d_xxen/06.2018 with coupling device AGH420 Insulation monitoring
More informationTechnical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter
Technical data sheet PowerLogic power-monitoring units series DIN Rail meter The Series DIN Rail Meter combines exceptional performance and easy installation to deliver a cost-effective solution for power
More informationMW/MVAR Transducer Specifications
GUARANTEED TECHNICAL PARTICULARS (To be submitted by bidder with the tender) MW/MVAR Transducer Specifications Sr.No. Descriptions Details Offered by supplier 1 2 3 4 Transducer suitable for Input Output
More informationPQM - Power Quality Monitoring
UMG 511 PQM - Power Quality Monitoring Class A power quality analyser according to IEC61000-4-30 The UMG 511 power quality analyser is particularly suitable for monitoring power quality according to standards
More informationZP120N Online UPS. High Power Intensity. Flexibility. High efficiency with low heat dissipation. Smart Energy Solutions
Online UPS 1,2,3,6,10,20 kva single/single-phase and three/single-phase High Power Intensity STRONGEST PERFORMANCE Flexibility High efficiency with low heat dissipation EXTENDABLE AUTONOMY Smart Energy
More informationNEMO HD MULTI-FUNC METER BASE (MF96001)
NEMO HD MULTI-FUNC METER BASE (MF96001) Quick and easy to install Compact modern design High accuracy monitoring and measurement to IEC 62053-21 Easy to read and configure Options for remote communication
More informationTechnical Specificaions. kwh Energy Meter
Technical Specificaions of kwh Energy Meter (SPK301) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationLED Driver Compact fixed output
Driver LC 30W 700mA fixc SR ADV2 advanced series Product description Independent driver with strain-relief housing Extra flat housing for constrained installation conditions (small ceiling cut outs and
More informationTRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:
Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs
More informationB+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.
SDM630 Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 203 V. Important Safety Information is contained in the Maintenance section. Familiarize yourself with this
More informationMultifunction Transducer MT440
Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up
More informationString Inverter (SUN2000-8/12KTL)
String Inverter (SUN2000-8/12KTL) 2 MPPTs for versatile adaptions to different module types or quantities built up with different alignments 4 strings intelligent monitoring and 80% time saving for fault
More informationProduct Sheet ECO. Types ECG, AMF Technical data. product sheet eco ecg-amf - technical data gb v1.0.docx
ECO Types ECG, AMF Technical data Product overview ECO ECG and ECO AMF are microprocessor controlled devices for use in low voltage single genset applications for standby power generation. The front-side
More informationSDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems
SDM630M CT DIN Rail Energy Meter for Single and Three Phase Electrical Systems Measures kwh Kvarh, KW, Kvar, KVA, P, F, PF, Hz, dmd, V, A, THD,etc. Bi-directional measurement IMP & EXP Two pulse outputs
More information100% electricity. Power factor correction components
100% ity Power factor correction components Automatic power factor regulators DCRK Digital programming 5 or 7 step configuration in 96x96mm housing 8 or 12 step configuration in 144x144mm housing Capacitor
More informationLED Driver Compact fixed output
Driver LC 35W 700mA fixc SC ADV China Domestic ADVANCED series Product description Fixed output LED Driver Can be either used build-in or independent with clip-on strain-relief (see accessory) Constant
More informationPower Factor Controller
Elnet LTC Power Factor Controller Table of Contents CHAPTER 1 Electrical Wiring...3 1.1 Electrical Connections...3 1.2 Electrical Wiring Diagrams...5 1.3 Indication Leds...7 1.4 Test Capacitors Screen...8
More informationHYBRID PV INVERTERS HySpirit Series. 4kW-10kW. Hybrid Inverter with Battery Backup Smart Energy for Smart Home
HYBRID PV INVERTERS HySpirit Series Hybrid Inverter with Battery Backup Smart Energy for Smart Home 4kW-10kW FSP HySpirit series Offers a more intelligent power solution for our customers to reduce the
More informationATS CONTROLLER OPERATING MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER OPERATING MANUAL Smartgen Electronic CONTENT 1 SUMMARY... 4 2 PERFORMANCE AND CHARACTERISTICS... 4 3 SPECIFICATION... 5 4 OPERATING... 6 4.1
More informationLED Driver Compact fixed output
Driver LC 38W 900mA fixc SR ADV2 advanced series Product description Independent driver with strain-relief housing Extra flat housing for constrained installation conditions (small ceiling cut outs and
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationNeon pr. ph/ ORP measurement. Applications. Description
Easy handling by graphical menue Fitting for your application by modular setup Simple firmware update and configuration using SD-card Applications Process Water Drinking Water / Beverages Waste Water Treatment
More informationFU2200B FU2200B V Ethernet Power Meter with Data Logger. Features. Applications
FU2200B 0-800V Ethernet Power Meter with Data Logger FU2200B is a three-phase multifunction power and energy meter manufactured by GFUVE. The meter provide excellent value for monitoring power and energy
More informationICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017
ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules
More informationPower factor correction (PFC) and harmonics filter
Power factor correction (PFC) and harmonics filter 08 Power factor correction (PFC) and harmonics filter Prophi power factor controller Optimised control for longer service life The universal capacitor
More informationRM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary
Characteristics voltage control relay RM17-U - range 183..528 V AC Main Range of product Product or component type Relay type Product specific application Relay name Relay monitored parameters Time delay
More informationLED Driver Compact fixed output
Driver LC 35W 350/500mA flexc SR ADV ADVANCED series Product description Independent constant current LED Driver Adjustable output current between 350 and 500 ma Max. output power 35 W Up to 88 % efficiency
More informationPGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationRevenue Grade NEMA 4X THE BYRAM. Electric Meter
Meets ANSI and IEC Standards Quick and Easy to Install Revenue Grade NEMA 4X THE BYRAM Electric Meter Tenant Billing Multi-Family Commercial Office & Retail Industrial & Manufacturing Educational Government
More informationFeeder/ Motor Protection Relay VAMP 40
Feeder/ Motor Protection Relay Feeder/motor protection relay Main characteristics Complete protection Comprehensive selection of protection functions for distribution network overhead line feeders, cable
More informationProcess modules Digital input PMI for 24 V DC inputs for 120 V AC inputs
E031026 000823 Process modules Digital input PMI for inputs for 120 V AC inputs PMI Input E4, E5, GND L- PMI 120 V AC Input E4, E5, Common C E6, E7, GND L- E6, E7, Common C LEDs for the inputs operation
More informationA0750 AC-DC POWER MODULE
FEATURES High power density, 7.7W / in³ Net Weight:< 2.2 KG Low profile : 40.8mm (fit 1U 19 shelf R2250 series) Efficiency: 77% ~ 86 % typical Power factor correction (meet IEC1000-3-2 requirements) Overvoltage
More informationMeasurement and Control CVM-A1500. Power analyzer with power quality. Quality in every sense of the word. Technology for energy efficiency
Measurement and Control CVM-A1500 Power analyzer with power quality Quality in every sense of the word Technology for energy efficiency Your network quality, at a glance The CVM-A1500 records power quality
More informationwith Backlight Graphic LCD Screen
with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More information