Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL

Size: px
Start display at page:

Download "Single Phase Vacuum Capacitor Switch. UltraVacLT 15kV 95kV or 125kV BIL"

Transcription

1 Trinetics UltraVacLT Single Phase Vacuum Capacitor Switch Installation and Operation Instructions UltraVacLT 15kV 95kV or 125kV BIL UltraVacLT 27kV 125kV or 150kV BIL Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications Hubbell Incorporated hpsliterature@hubbell.com hubbellpowersystems.com

2 DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Hubbell Power Systems, Inc.'s (HPS) experience and judgment and may not cover all contingencies. If further information is required, an HPS sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate HPS selling policies or other contractual agreement between Hubbell Power Systems and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF HUBBELL POWER SYSTEMS. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. IN NO EVENT AND UNDER NO CIRCUMSTANCE SHALL HPS BE RESPONSIBLE TO THE PURCHASER OR USER OF THIS DOCUMENT OR THE PRODUCT DESCRIBED HEREIN OR ANY OTHER PERSON IN CONTRACT, IN TORT (INCLUDING NEGLIGENCE OR WRONGFUL DEATH), STRICT LIABILITY OR OTHERWISE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES OR LOSSES WHATSOEVER, INCLUDING BUT NOT LIMITED TO DAMAGE OR LOSS OF USE OF PRODUCT, EQUIPMENT, PLANT OR POWER SYSTEM, COST OF CAPITAL, LOSS OF POWER, ADDITIONAL EXPENSES IN THE USE OF EXISTING POWER FACILITIES, OR CLAIMS AGAINST THE PURCHASER OR USER BY THIRD PARTIES RESULTING FROM THE USE OF THE INFORMATION, RECOMMENDATIONS AND DESCRIPTIONS CONTAINED HEREIN. THE INFORMATION CONTAINED IN THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE, USER SHOULD CONSULT THE HUBBELL POWER SYSTEMS WEBSITE FOR THE MOST CURRENT VERSION. 2

3 Table of Contents Safety Information Safety Information...4 Product Information Introduction...5 Acceptance and Initial Inspection...5 Handling and Storage...5 Standards...5 Quality Standards...5 Description of Operation...5 Ratings and Specifications Check Switch Ratings Before Installation...6 Ratings...6 Installation Procedure Check-Out Procedure...7 High Voltage Connections...8 Control Wiring...9 Remote Control...9 Wiring Diagrams... 10,11 Dimensions Dimensions...12 Switch Operation Electrical Operation Manual Hotstick Operation Contact Position Indicator Service Information Service Requirements Frequency of Inspection

4 Safety Information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment, and is trained in the care and use of personal protective equipment such as flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. The following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings before installing or operating. This manual may contain four types of hazard statements: DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious injury.! WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury.! CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. CAUTION Indicates a hazardous situation which, if not avoided, could result in equipment damage only. The following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locally approved safety procedures when working around high- and low-voltage lines and equipment.! WARNING Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling or maintenance can result in death, severe personal injury, and equipment damage.! WARNING This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage.! WARNING Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage.! WARNING Switch housing is composed of HDPE which is not self extinguishing and may continue to burn if ignited. Consideration of flammability requirements for application should be validated prior to installation. Failure to comply can result in death, severe personal injury, and equipment damage. 4

5 Product Information Introduction This service information document provides installation instructions, operation information, and maintenance information for UltraVacLT Vacuum Capacitor Switches. The information contained in this manual is organized into the following major categories: Safety Information, Product Information, Ratings and Specifications, Installation Procedure, Dimensions, Switch Operation, and Service Information. Refer to the table of contents for page numbers. Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment. Additional information These instructions cannot cover all details or variations in the equipment, procedures, or processes described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user's purpose, please contact your Hubbell Power Systems sales representative. Acceptance and initial inspection Each capacitor switch is completely assembled, inspected, tested, and adjusted at the factory. It is in good condition when accepted by the carrier for shipment. Upon receipt of a capacitor switch, inspect the capacitor switch thoroughly for damage and loss of parts incurred during shipment. If damage or loss is discovered, file a claim with the carrier immediately. Handling and storage If the capacitor switch is to be stored for an appreciable time before installation, provide a clean, dry storage area. Store the capacitor switch so as to minimize the possibility of mechanical damage. Maximum temperature of product during storage should never exceed 70 C. Care should be taken to ensure storage location and packaging is appropriate. If stored outside in original cartons and temperatures above 45 C are expected, shipping wrap should be removed and handle knock-outs should be opened to ensure airflow into carton. Standards UltraVacLT Vacuum Capacitor Switches are designed and tested in accordance with IEEE Std C standard. Quality standards UltraVacLT Vacuum Capacitor Switches are produced under an ISO 9001 Certified Quality Management System. Description of operation The UltraVacLT Vacuum Capacitor Switch is a single-phase, solenoid-operated vacuum switch. The solid polymer insulation system does not rely on gas, foam, or liquid dielectrics. Highly resistant to ozone, oxygen, moisture, contamination, and ultraviolet light, it is an environmentally friendly capacitor switch. The UltraVacLT Vacuum Capacitor Switch has a polymer bushing and is suitable for operation through a temperature range of -40 C to +60 C. 5

6 Ratings and Specifications Check switch ratings before installation The UltraVacLT Vacuum Capacitor Switch must be applied within its specified ratings. Check data plate ratings and compare with the system characteristics at the point of application prior to installation. Table 1 lists the ratings and specifications for the UltraVacLT Vacuum Capacitor Switch. Ratings All ratings meet or exceed values in IEEE Std C standard for a distribution-class switch, where applicable. Table 1 - Ratings and Specifications Model UltraVacLT 15 UltraVacLT 27 Rated Maximum Voltage, 50/60Hz for ungrounded capacitor banks, line-to-line, kv, RMS Rated Maximum Voltage, 50/60Hz for grounded capacitor banks, line-to-line, kv, RMS Impulse Withstand Voltage, Line-to-ground, kv BIL Impulse Withstand Voltage, Open gap, kv BIL Power frequency withstand voltage, 60 Hz: 1 Minute Dry, kv 10 Seconds Wet, kv Continuous Current, 50/60Hz, Amps Capacitive Switching Current, 50/60Hz, Amps Fault making peak current, Amps 15,000 15,000 Fault making current, symmetrical RMS, Amps 6,000 6,000 Short time withstand current 1.0 s, symmetrical RMS, Amps 6,000 6,000 High frequency peak Transient making current, Amps Transient in-rush frequency, Hz Operating current rating 120VAC, Amps 240VAC, Amps 125VDC, Amps Operating voltage range 120VAC, Volts 240VAC, Volts 125VDC, Volts ,000 6, to to to ,000 6, to to to 144 Nominal open/close time, ms Creep distance, terminal to terminal, inches / mm terminal to ground, inches / mm 20.3 / / / / 635 Weight, lbs / kg 20 / 9 22 / 10 Operating temperature range, deg F / deg C -40 to +140 / -40 to to +140 / -40 to +60 Humidity % Mechanical Operations 50,000 50,000 Restrike category per IEEE standards, Class C2 C2 Insulation Type High Density Polyethylene High Density Polyethylene Standards ANSI/IEEE ANSI/IEEE Standard Terminal Type Eye bolt clamps Eye bolt clamps 6

7 Installation Procedure Hazardous voltage. Solidly ground all equipment. Failure to comply can result in death, severe personal injury, and equipment damage. This equipment is not intended to protect human life. Follow all locally approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury and equipment damage. Check-out procedure! WARNING! WARNING 1..Check data plate. Make sure that ratings on the data plate are correct for the planned installation. 2. Visually inspect the switch. Visually inspect the switch for any damage to bushing sheds, terminals, mounting bracket, or trip handle. 3. Install the switch. Follow locally approved installation procedures. 4..Install system components. This equipment is not intended as a visual break disconnect. Air-breaking isolating switches, usually fused cutouts, must be installed to provide a visible disconnect. 5..Adjust orientation. When mounting the switch in its final location, the orientation of the side terminal can be adjusted for best wire routing. This is done by rotating the body of the switch in the mounting clamp ring. To make this adjustment, loosen the two (2) nuts on the clamp ring until the body of the switch is free to rotate. Rotate the switch body to the desired orientation. Tighten the two (2) nuts to 15ft-lbs to secure the switch and prevent additional rotation. The switch body can be rotated approximately 275 degrees as shown below. CAUTION When adjusting the rotation position of the switch, do not locate the mounting bracket under the manual handle/indicator as this will prevent proper operation of the switch. Range of Rotation Grounding Connection Clamp Ring Nuts 7

8 High-Voltage Connections 1. Ground the switch. Make the ground connection to the ground connector located on the mounting bracket of the switch. 2. Make line connections. Connect the primary leads to the switch terminals. The universal clamp-type terminals accommodate AWG No. 8 solid through 2/0 stranded conductor. Animal guards for terminal connections are provided with each switch. 3. Torque specification to terminals is 15 ft-lbs. CAUTION When connecting system line voltage to the UltraVacLT Vacuum Capacitor Switch, wire leads must be kept at least 6 inches away from the upper sheds area of the switch bushing. Failure to comply with this precaution may result in improper operation of the capacitor switch. Refer to diagram below. Keep this area around switch sheds completely free of all line voltage wiring to prevent improper operation Keep this area around switch sheds completely free of all line voltage wiring to prevent improper operation 8

9 Control Wiring Electrical connections to the actuating mechanism are made through the receptacle in the bottom cover plate of the switch. Mating plugs or cable assemblies for the receptacle must be ordered separately. Pin orientation diagrams for the control receptacle are shown next to each available wiring configuration on the next pages. Connector receptacle Remote Control Remote control of the UltraVacLT Vacuum Capacitor Switch is accomplished by connecting the customer's control device to the receptacle in the bottom cover plate of the switch. The control signal must be applied between the CLOSE or OPEN pin and Neutral for at least 100 msec. It is recommended the control signal be applied for 1 second +/- 100ms. Limit switches inside the switch will open the control path to the solenoid at the correct time.! CAUTION The CLOSE or OPEN signal must be removed from the corresponding path before the opposite signal is applied or damage to the solenoid circuit will occur. Any manual switch, relay contact, time switch, or similar device can be used, provided the control circuit is energized for a minimum of 100 ms for each operation.! CAUTION The UltraVacLT Vacuum Capacitor Switch is designed for use on distribution capacitor banks which typically operate a few times a day. To provide optimum operating performance, the mechanism of this switch is designed for intermittent duty operation. If performing functional testing of the switch; either on a bench or in a complete capacitor bank system; repetitive CLOSE and OPEN operations must be limited to a maximum of 20 operations in a 5 minute time period with the operations spaced an equal time apart. After these test operations, the switch must be allowed to rest without further electrical operations for a period of approximately 20 minutes. This will allow the components inside the switch sufficient time to cool and be ready for additional testing operations if desired.! CAUTION If the UltraVacLT Vacuum Capacitor Switch is used to switch distribution capacitors, a minimum 5 minute delay must be provided between any open operation and the subsequent close operation to prevent damage to equipment or injury to personnel. 9

10 Wiring Diagrams Schematic of switch actuator circuits are shown in the following diagrams. Option Code: X5 Option Code: W5 Option Code: A5 Option Code: B5 10

11 Option Code: C6 Option Code: D7 Option Code: D8 11

12 Dimensions ULT15-095/ULT ULT27-125/ULT Mounting Bracket Details 12

13 Switch Operation Electrical Operation The switch may be opened and closed electrically by applying rated control voltage to the proper terminals of the actuator receptacle. Refer to the Installation Procedure section of this manual for electrical connections and operating time. CAUTION UltraVacLT Vacuum Capacitor Switches operating on 120 VAC or 125 VDC require 9 amps of current per switch; 27 amps for a group of 3 switches. Switches operating on 240 VAC require 4.5 amps per switch; 13.5 amps for a group of 3 switches. The voltage source must be of sufficient volt-ampere rating to provide these currents for the 100 millisecond time period that operating current is being consumed. Insufficient source capacity may result in malfunction of the switches and possible damage to the internal circuitry. Manual Hotstick Operation DANGER Hazardous voltage. This device is not a substitute for a visible disconnect. Follow all locally approved safety practices. Failure to follow proper safety practices can result in contact with high voltage, which will cause death or severe personal injury. The switch may be manually opened or closed by using a hotstick to operate the yellow manual operating handle under the sleet hood as shown in figures below. DANGER Hazardous voltage. Do not rely on the open position of the yellow operating handle; it does not ensure that the line has been de-energized. Always establish a visible disconnect. Failure to follow proper safety practices can result in contact with high voltage, which will cause death or severe personal injury. To open the switch contacts, insert the hotstick tip into the hotstick hole of the manual operating handle and pull downward to the OPEN position. To close the switch contacts, place the hotstick tip into the notch under the hotstick hole of the manual operating handle and push upward to the CLOSED position. Hotstick in place with switch closed Hotstick in place with switch open Hotstick in place to close switch 13

14 Contact Position Indication The yellow operating handle is also used as a contact position indicator. The switch is closed when the operating handle is in the up position and is open when the operating handle is in the down position. Contact position indicator switch closed Contact position indicator switch open Service Information Service Requirements The mechanical durability of the UltraVacLT Vacuum Capacitor Switch was demonstrated by completing a minimum of 50,000 mechanical operations. The switch requires no routine maintenance; however, the switch should be inspected on a regular basis to check for physical damage and to verify operation. The bottom cover of the unit should not be removed as there are no user serviceable parts inside. Frequency of Inspection Because these switches are applied under widely varying operation and climatic conditions, maintenance intervals are best determined by the user based upon actual operating experience.! WARNING Hazardous voltage. If, during the inspection of the UltraVacLT Vacuum Capacitor Switch, a dielectric test is to be conducted, caution must be taken to insure appropriate clearances and/or guarding are incorporated to protect personnel conducting the tests. Recommended field dielectric test levels are 75% of the rated power frequency withstand level.! CAUTION RADIATION Radiation. At voltages up to the specified test voltages, the radiation emitted by the vacuum interrupter is negligible. However, above these voltages, radiation injurious to personnel can be emitted. 14

15 NOTES 15

16 Hubbell Power Systems, Inc. N88 W13901 Main Street Menomonee Falls, WI (262) Hubbell has a policy of continuous product improvement. Please visit hubbellpowersystems.com to confirm current design specifications Rev 0 TD_10_055_E 2016 Hubbell Incorporated hpsliterature@hubbell.com hubbellpowersystems.com

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN

COOPER POWER SERIES. Input/Output (I/O) module installation instructions. Voltage Regulators MN225067EN Voltage Regulators MN225067EN Effective November 2016 Supersedes June 2014 (S225-70-13) COOPER POWER Input/Output (I/O) module installation instructions SERIES DISCLAIMER OF WARRANTIES AND LIMITATION OF

More information

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN

COOPER POWER SERIES. 600 A U-OP visible break connector system operation instructions. Deadbreak Apparatus Connectors MN650022EN Deadbreak Apparatus Connectors MN650022EN COOPER POWER Effective March 2016 Supersedes S600-14-1 June 2010 SERIES 600 A U-OP visible break connector system operation instructions DISCLAIMER OF WARRANTIES

More information

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents

S Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions. Contents Sectionalizers Types TVS15 and TVS27 Time Voltage Sectionalizer Installation and Operation Instructions Service Information S270-30-1 Figure 1. Kyle Type TVS Time-Voltage Sectionalizer. Contents 010032KM

More information

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN

COOPER POWER SERIES. RS-485 digital communications accessory board installation and operation instructions. Voltage Regulators MN225074EN Voltage Regulators MN225074EN Effective March 2017 Supersedes January 2012 (S225-40-7) RS-485 digital communications accessory board installation and operation instructions COOPER POWER SERIES DISCLAIMER

More information

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN

COOPER POWER SERIES. Visible-Break switch accessory operation instructions. Padmounted switchgear MN285011EN Padmounted switchgear MN285011EN Effective May 2017 Supersedes November 2004 (S285-10-4) Visible-Break switch accessory operation instructions COOPER POWER SERIES DISCLAIMER OF WARRANTIES AND LIMITATION

More information

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN

COOPER POWER SERIES. DC motor operator control installation and operation instructions. Padmounted Switchgear MN285018EN Padmounted Switchgear MN285018EN Effective May 2017 Supersedes October 1994 (S285-80-1) COOPER POWER SERIES DC motor operator control installation and operation instructions DISCLAIMER OF WARRANTIES AND

More information

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN

COOPER POWER SERIES. Fiber-optic/RS-232 communications module installation and operation instructions. Voltage Regulators MN225020EN Voltage Regulators MN225020EN Effective May 2015 Supersedes S225-40-4 November 2011 COOPER POWER Fiber-optic/RS-232 communications module installation and operation instructions SERIES DISCLAIMER OF WARRANTIES

More information

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME

S Contents. Figure 1. Kyle Form 4C Analog Current Metering Accessory KME Reclosers Form 4C Microprocessor-Based Recloser Control Analog Current Metering Accessory KME4-82-1, KME4-82-2 Installation and Operation Instructions Service Information S280-77-8 Figure 1. Kyle Form

More information

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II

S Reclosers Form 4C Microprocessor-Based Recloser Control KME (120V) and KME (240V) Analog Current Metering Accessory Design II Reclosers Form 4C Microprocessor-Based Recloser Control KME4-88-1 (120V) and KME4-88-2 (240V) Analog Current Metering Accessory Design II Service Information S280-77-6 961015, 961016 Figure 1. Kyle KME4-88

More information

COOPER POWER SERIES. Form 4C microprocessor-based recloser control standard and automation power supply kit installation and operation instructions

COOPER POWER SERIES. Form 4C microprocessor-based recloser control standard and automation power supply kit installation and operation instructions Reclosers MN280033EN Effective December 2015 Supersedes S280-77-9 July 2002 COOPER POWER SERIES Form 4C microprocessor-based recloser control standard and automation power supply kit installation and operation

More information

COOPER POWER SERIES. Ethernet communications module installation and operation instructions. Voltage Regulators MN225033EN

COOPER POWER SERIES. Ethernet communications module installation and operation instructions. Voltage Regulators MN225033EN Voltage Regulators MN225033EN Effective February 2016 Supersedes S225-40-8 October 2012 COOPER POWER SERIES Ethernet communications module installation and operation instructions DISCLAIMER OF WARRANTIES

More information

Elastimold Molded Vacuum Recloser - MVR

Elastimold Molded Vacuum Recloser - MVR Subject: Elastimold Recloser Technical Specification Date: 4/24/12 File: MVR-RS-0412 Page: 1 of 6 1.0 SCOPE Elastimold Molded Vacuum Recloser - MVR 1.1 This specification covers electrical and mechanical

More information

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch installation instructions SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch 2013 Hubbell Incorporated hpsliterature@hubbbell.com hubbbellpowersystems.com The equipment covered by these installation

More information

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

Multi Unit Enclosed Meter

Multi Unit Enclosed Meter Contents Description Page Introduction Preliminary comments and safety precautions............................... 2 Warranty and liability information................ 2 Safety precautions..............................

More information

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT

MODEL SST3-MV INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SST3-MV SELECTABLE SIRENTONE-MULTI VOLT MODEL INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT INSTALLATION INSTRUCTIONS FOR FEDERAL MODEL SELECTABLE SIRENTONE-MULTI VOLT A. GENERAL. The Federal Model is a solid-state

More information

HV-CS kv Edge Mount Triaxial Jack

HV-CS kv Edge Mount Triaxial Jack Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley HV-CS-1589 3 kv Edge Mount Triaxial Jack Installation Information Description The Keithley Instruments

More information

COOPER POWER SERIES. Type GN3E and GN3VE sectionalizers installation and operation instructions

COOPER POWER SERIES. Type GN3E and GN3VE sectionalizers installation and operation instructions Sectionalizers MN270001EN Effective December 2015 Supersedes S270-15-1 June 2002 Type GN3E and GN3VE sectionalizers installation and operation instructions GN3E serial number 5750 and above GN3VE serial

More information

Digitrip 520MC with Maintenance Mode

Digitrip 520MC with Maintenance Mode Digitrip 520MC with Maintenance Mode Effective May 2006 I.S 70C1454 Supplement to I.L. 70C1037 FIGURE 1. Digitrip 520MC with ARMs in Magnum Circuit Breaker Table of Contents 1.0 General... 2 2.0 Maintenance

More information

Model VT120 Fast Timing Preamplifier Operating and Service Manual

Model VT120 Fast Timing Preamplifier Operating and Service Manual Model VT120 Fast Timing Preamplifier Operating and Service Manual Printed in U.S.A. ORTEC Part No. 740360 1202 Manual Revision C Advanced Measurement Technology, Inc. a/k/a/ ORTEC, a subsidiary of AMETEK,

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

INCOM communications adapter module

INCOM communications adapter module Instruction Leaflet IL0131124EN Supersedes July 2016 INCOM communications adapter module Power Defense ICCB Instructions apply to: UL489 : PD-NF UL489 : PD-RF IEC : PD-NF, IZMX16 IEC : PD-RF, IZMX40 WARNING

More information

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD) Instruction Bulletin 8222-0513B Retain for future use. SPIKESHIELD Wired-In Branch Panels 8222-0513B 05/2012 Table of Contents Precautions...

More information

Series NRX drawout circuit breaker and cassette rejection interlocks

Series NRX drawout circuit breaker and cassette rejection interlocks Series NRX Instructions apply to: UL 1066/ANSI, UL489 series NRX NF frame IEC IZMX16 UL489 series NRX RF frame IEC IZMX40 WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON

More information

Model 2657A-LIM-3 LO Interconnect Module

Model 2657A-LIM-3 LO Interconnect Module Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Model 2657A-LIM-3 LO Interconnect Module User's Guide Description The Model 2657A-LIM-3 LO Interconnect

More information

Time delay undervoltage module

Time delay undervoltage module Supersedes December 2010 Power Defense ICCB Series NRX IZMX Instructions apply to: UL489 IEC UL1066/ANSI : PD-NF, Series NRX NF : PD-NF, IZMX16 : Series NRX NF UL489 : PD-RF IEC : PD-RF, IZMX40 120VAC

More information

S Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions.

S Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions. Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions NOVA 15 for Serial Number CP571297544 and above NOVA 27 for Serial Number CP571300976

More information

Vista SD Portable Remote Control Pendant

Vista SD Portable Remote Control Pendant S&C Vista SD Underground Distribution Switchgear Pad-Mounted and Vault-Mounted Styles Outdoor Distribution (17.5 kv and 29 kv) With Visi-Gap Load Interrupter Switches and Visi-Gap Fault Inetrrupters Vista

More information

S Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions

S Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions Reclosers Types NOVA 15, NOVA 27, and NOVA 38; Three-Phase Microprocessor-Controlled; Installation and Operation Instructions NOVA 15 for Serial Number CP571297544 and above Service Information S280-42-1

More information

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-STC Kelvin Standard Triaxial Connector Card Description The Model 8020-STC Kelvin Standard

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

Installation Instructions

Installation Instructions 50ES, 50EZ, 50GL, 50GS, 50GX, 50JS, 50JX, 50JZ, 50SD, 50SZ, 50VL, 50VT, 50XP, 50XZ 601A, 602A, 602B, 604A, 604B, 604D, 607C, 701A, 702A, 702B, 704A, 704B, 704D, 707C PA1P, PA2P, PA3P, PH1P, PH2P, PH3P

More information

Primary Injection Test Procedure

Primary Injection Test Procedure S&C IntelliRupter PulseCloser Fault Interrupter Outdoor Distribution (15.5 kv, 27 kv, and 38 kv) Primary Injection Test Procedure Table of Contents Section Page Section Page Introduction Qualified Persons....

More information

5504 Thermocouple Analog Input Module

5504 Thermocouple Analog Input Module 550 Thermocouple Analog Input Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 8020-KHV Kelvin Keithley Triaxial Connector Card Description The Model 8020-KHV Keithley HV Connector

More information

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-3K-KIT 3 kv Bias Tee Kit Description The CVU-3K-KIT Bias Tee Kit consists of three bias tees for

More information

Installation and Operation

Installation and Operation S&C TripSaver II Cutout-Mounted Recloser Outdoor Distribution (15 kv and 25 kv) Cordless Power Module Installation and Operation Table of Contents Section Page Section Page Introduction Qualified Persons....

More information

S82S (3/7.5-W Models)

S82S (3/7.5-W Models) Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC

More information

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide Model P4017 Single Channel USB Oscilloscope Quick Start Guide General Warranty BNC warrants that the product will be free from defects in materials and workmanship for 3 years from the date of purchase

More information

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-200-KIT 200 V Bias Tee Kit Description The CVU-200-KIT Bias Tee Kit consists of three 2600-RBT-200

More information

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A Solid State Relays CSM DS_E_4_1 Compact, Low-cost, SSR Switching 5 to 20 A Wide load voltage range: 75 to 264 VAC. Both 100-V and 200-V loads can be handled with the same model. Dedicated, compact aluminum

More information

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND

More information

Model 2380 Rack-Mount Kit

Model 2380 Rack-Mount Kit Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount

More information

S Reclosers. Contents. Form 4C Recloser Control Protocol Conversion Kits KME , -7002, and Installation Instructions

S Reclosers. Contents. Form 4C Recloser Control Protocol Conversion Kits KME , -7002, and Installation Instructions Reclosers Form 4C Recloser Control Protocol Conversion Kits KME4-589-7001, -7002, and -7003 Installation Instructions Service Information S280-77-11 DB-9 Connector for MODBUS/FSK option RS-232 DB-9 Connector

More information

Eaton Innovative TechnologyT XT50/100 surge protective device

Eaton Innovative TechnologyT XT50/100 surge protective device Instruction Manual IM01005014E Supersedes January 2014 Eaton T /100 surge protective device Contents Description Page Introduction.... 2 Installation.... 2 Specifications... 7 Operation..... 7 Warranty...

More information

S Reclosers. Contents. Form 6 Recloser Control Disassembly, Reassembly, and Testing Instructions

S Reclosers. Contents. Form 6 Recloser Control Disassembly, Reassembly, and Testing Instructions Reclosers Form 6 Recloser Control Disassembly, Reassembly, and Testing Instructions Service Information S80-70- Figure. Kyle Form 6 Pole Mount, Yard Mount, and Rack Mount recloser controls. Contents Safety

More information

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1 Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2600B-PM-1 200 V Protection Module with 1 A Clamp Description The Model 2600B-PM-1 200 V Protection

More information

Voltage Detector and Phasing Tester Operating Instructions 83280

Voltage Detector and Phasing Tester Operating Instructions 83280 Voltage Detector and Phasing Tester Operating Instructions 83280 CONTENTS Warranty and Liability...2 Product Safety Information 3 Overview Voltage Detector and Phasing Tester... 4 Battery Test... 5 Sensing

More information

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English

Configurable Output Distribution. 120V / 208V / 240V 60Hz. User Manual English Configurable Output Distribution 120V / 208V / 240V 60Hz User Manual English TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS.......................... 1 GLOSSARY OF SYMBOLS....................................

More information

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual. The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings

More information

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH) Surge-Trap STZ-R series Surge Protective Device (SPD) Danger Hazard of Electrical Shock, Explosion or Arc Flash Only qualified licensed electricians should install or service SPDs Verify that all power

More information

5401 and 5402 Digital I/O Modules

5401 and 5402 Digital I/O Modules 50 and 50 Digital I/O Modules Installation, Operation and Maintenance Setup Manual 5/9/0 Safety Information The information provided in this documentation contains general descriptions and/or technical

More information

GridAdvisor Series II smart sensor installation instructions

GridAdvisor Series II smart sensor installation instructions Smart Sensors Effective October 2014 Supersedes S1150-20-1 June 2014 MN915001EN GridAdvisor Series II smart sensor installation instructions Note: This document applies to product serial numbers that contain

More information

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply

ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply October 2012 IL42-4031C ALPHA Plus and A3 ALPHA Switchboard Meters with the CPS Power Supply General This leaflet contains general installation instructions for ALPHA Plus and A3 ALPHA meters with the

More information

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System Part 1 General 1.01 Summary A. These specifications describe

More information

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE XBDM 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL www.xpcc.com 2013 Xtreme Power Conversion Corporation. All rights reserved. Table of Contents IMPORTANT SAFETY INSTRUCTIONS:... 4 INTRODUCTION...

More information

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs The IO-AO6X is an I/O Expansion Module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 6 12-bit isolated

More information

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter

Power Xpert Meter 350 (PXM350) three-phased DIN-rail multifunction meter Contents Description Page Product overview.... 2 Key features.... 2 Wide voltage range.... 2 Ordering information... 2 Additional features.... 2 functions comparison... 3 Metering.... 4 Specifications....

More information

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet

Installation NOTICE. S&C IntelliCap Automatic Capacitor Control. Table of Contents. Instruction Sheet S&C IntelliCap Automatic Capacitor Control Installation Table of Contents Section Page Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet...

More information

700 Series 200 Amp Clamp Meters

700 Series 200 Amp Clamp Meters 700 Series 200 Amp Clamp Meters #61-700 #61-701 #61-702 1 2 3 6 5 7 4 8 1. Non-contact voltage (NCV) (#61-701 and #61-702) With the NCV tab on the tip of the clamp close to an AC voltage, press the NCV

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

MAXIMA+ Series Rotary Level Indicator

MAXIMA+ Series Rotary Level Indicator MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE

More information

COM32. Installation & Operation Manual

COM32. Installation & Operation Manual COM32 Installation & Operation Manual DANGER ElectricaI equipment contains hazardous voltages and high speed moving parts. Can cause death, serious injury or property damage. See safety instruction contained

More information

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models Solid State Relays G3@-VD CSM_G3B_G3BD_DS_E_5_1 International Standards for G3B Series, Same Profile as MK Power Relays Shape-compatible with mechanical relays. Certified by UL, CSA, and VDE (models numbers

More information

Model 4001A Modular System Bin Operating and Service Manual

Model 4001A Modular System Bin Operating and Service Manual Model 4001A Modular System Bin Operating and Service Manual Printed in U.S.A. ORTEC Part No. 733740 0704 Manual Revision D $GYDQFHG0HDVXUHPHQW7HFKQRORJ\,QF a/k/a/ ORTEC, a subsidiary of AMETEK, Inc. WARRANTY

More information

iconverter 2-Module Power Chassis

iconverter 2-Module Power Chassis iconverter 2-Module Power Chassis User Manual 38 Tesla, Irvine, CA 92618 USA Phone: (949) 250-6510; Fax: (949) 250-6514 Page 1 Warning The operating description in this Instruction Manual is for use by

More information

Type VR Electrically Operated Ground and Test Device

Type VR Electrically Operated Ground and Test Device Type VR Electrically Operated Ground and Test Device For Use with Masterclad Switchgear 4.76 kv 15 kv, 1200, 2000, 3000, 4000 A Up to 63 ka Short Circuit Rating Class 6055 Instruction Bulletin 6055-37

More information

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-5B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-5B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

Solid State Relays with Failure Detection Function

Solid State Relays with Failure Detection Function Solid State Relays with Failure Detection Function CSM DS_E_2_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs

More information

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv)

Configuration. S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv) S&C Scada-Mate Switching System Outdoor Distribution (14.4 kv through 34.5 kv) Communication Processor Module For Communication and Control Unit Configuration Table of Contents Section Page Section Page

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Instructions for Testing Magnum DS Trip Units Using PACB Test Kit Styles 87C0270G01-G03

Instructions for Testing Magnum DS Trip Units Using PACB Test Kit Styles 87C0270G01-G03 Instructions for ing Magnum DS Trip Units Contents Description Page 1: Introduction............................ 2 2: Kit / Breaker Information.............. 2 3: Kit Setup.......................... 3 4:

More information

Solar Combiner Enclosure

Solar Combiner Enclosure Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the

More information

2260B-RMK-Series Rack Mount Kit

2260B-RMK-Series Rack Mount Kit Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY http://www.keithley.com Assembly and Mounting Instructions Introduction The 2260B-RMK-Series Rack Mount Kit is suited for

More information

Broadband Automatic Disconnect Switch. User Manual

Broadband Automatic Disconnect Switch. User Manual Reset/Test Primary/ Primary Broadband Automatic Disconnect Switch User Manual Local Power Remote Pwer Local 63V Fault Secondary Select Secondary 220V Normal 990-1929 09/2004 Introduction Introduction

More information

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide EL1142 Series IEC 61850 / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter User s Guide All Rights Reserved Dissemination or reproduction of this document, or its contents,

More information

C5C Cross-Connect System

C5C Cross-Connect System C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection

More information

MAXIMA + Series ROTARY LEVEL CONTROL

MAXIMA + Series ROTARY LEVEL CONTROL Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A

More information

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-7B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-7B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

V E2B Snap-in I/O Module

V E2B Snap-in I/O Module i4 Automation Ltd - 01480 395256 V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration.

More information

Always "On" UPS Systems Inc. USER MANUAL

Always On UPS Systems Inc. USER MANUAL Always "On" UPS Systems Inc. SMART HOME PROTECTOR USER MANUAL Bldg 1-150 Campion Road, Kelowna, BC, Canada, V1X 7S8 Phone: (250) 491-9777 Ext. 451, Fax: (250) 491-9775, Email: sales@alwaysonups.com Web

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Vapor Monitor Interface Module

Vapor Monitor Interface Module Manual No: 577013-951 Revision: A Vapor Monitor Interface Module Installation Guide Notice Veeder-Root makes no warranty of any kind with regard to this publication, including, but not limited to, the

More information

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-4B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-4B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

Agilent Technologies E5339A 38-Pin Low-Voltage Probe

Agilent Technologies E5339A 38-Pin Low-Voltage Probe Agilent Technologies E5339A 38-Pin Low-Voltage Probe Installation Note The 38-pin low-voltage probe provides a convenient way to connect two Agilent Technologies logic analyzer probe cables to a small

More information

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES

INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES INSTRUCTION MANUAL RA 19-6B RACK ADAPTER HOT SWAP RACK ADAPTER FOR HSF SERIES POWER SUPPLIES KEPCO INC. An ISO 9001 Company. MODEL RA 19-6B RACK ADAPTER ORDER NO. REV. NO. IMPORTANT NOTES: 1) This manual

More information

DIGITAL VOLTAGE INDICATOR

DIGITAL VOLTAGE INDICATOR DIGITAL VOLTAGE INDICATOR Instruction Manual US Patent 6,998,832 HD ELECTRIC COMPANY 1475 LAKESIDE DRIVE WAUKEGAN, ILLINOIS 60085 U.S.A. PHONE 847.473.4980 FAX 847.473.4981 website: www.hdelectriccompany.com

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models Solid State Relays CSM DS_E_5_3 100-μA-max. Leakage Current, No Bleeder Resistor Required Reduces wiring work by 60% when combined with the PFY-08- PU Push-In Plus Socket (according to actual OMRON measurements).

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216 Instruction Bulletin 30072-452-48 Retain for future use. 30072-452-48 Altivar 61/71 Heatsink Fan Kits VZ3V1212 and VZ3V1216

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR

SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR SE-135 MANUAL GROUND-FAULT GROUND-CHECK MONITOR AUGUST 14, 2001 REVISION 1 Publication: SE-135-M Document: S95-C135-00000 Printed in Canada. Copyright 2001 by Startco Engineering Ltd. All rights reserved.

More information

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English) Total Home Surge Protection for Point-of-Entry FirstSurge TM User Manual - Canada (English) www.siemens.ca/surge Introduction Thank you for choosing the Siemens FirstSurge Residential Surge Protective

More information

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS

CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS CONNECTOR AND RECEPTACLE WIRE/CABLE ASSEMBLY INSTRUCTIONS Throughout this manual, look for this symbol. It means BE ALERT YOUR SAFETY IS INVOLVED. If you do not follow these safety instructions, personal

More information

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018

SIRIUS CAPACITOR MODULE User Manual. Model number: A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 SIRIUS CAPACITOR MODULE User Manual Model number: 3550-48-A-1.7C-M-SD-G Version 1.0; Release Date: April 2018 Introduction The Sirius Capacitor Module ( Sirius ) is supercapacitor-based storage that uses

More information

Installation Job Aid for Ethernet Routing Switch 3600 Series

Installation Job Aid for Ethernet Routing Switch 3600 Series Installation Job Aid for Ethernet Routing Switch 3600 Series Notices NN47213-303 Issue 03.01 November 2017 Notice paragraphs alert you about issues that require your attention. Following are descriptions

More information

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849

More information