STORAGE CONFIGURATION BEST PRACTICES FOR SAP HANA TAILORED DATA CENTER INTEGRATION ON EMC VNX SERIES UNIFIED STORAGE SYSTEMS
|
|
- Bridget Fleming
- 6 years ago
- Views:
Transcription
1 STORAGE CONFIGURATION BEST PRACTICES FOR SAP HANA TAILORED DATA CENTER INTEGRATION ON EMC VNX SERIES UNIFIED STORAGE SYSTEMS Integrating SAP HANA into an EMC VNX storage system EMC Solutions Abstract This solution guide provides information on a new concept that overcomes limitations of the current SAP HANA Appliance Model. Using Tailored Data Center Integration (TDI) on EMC VNX storage systems, customers can integrate SAP HANA into an existing, well-established data center infrastructure, providing multiple benefits. April 2017
2 Copyright Disclaimer This document outlines a general product direction and should not be relied on in making a purchase decision. This document is not subject to your license agreement or any other agreement with EMC or SAP. Neither EMC nor SAP has an obligation to pursue any course of business outlined in this document or to develop or release any functionality mentioned in this document. This document and the strategy and possible future developments of EMC or SAP are subject to change and may be changed by EMC or SAP at any time for any reason without notice. This document is provided without a warranty of any kind, either express or implied, including but not limited to, the implied warranties of merchantability, fitness for a particular purpose, or non-infringement. EMC and SAP assume no responsibility for errors or omissions in this document, except if such damages were caused by EMC or SAP intentionally or through gross negligence. No part of this publication may be reproduced or transmitted in any form or for any purpose without the express permission of EMC and SAP AG. Copyright 2017 SAP. All Rights Reserved. SAP and other SAP products and services mentioned herein as well as their respective logos are trademarks or registered trademarks of SAP AG in Germany and in other countries. See for additional trademark information and notices. Copyright 2017 EMC Corporation. All rights reserved. Published April 2017 in the USA. EMC believes the information in this publication is accurate as of its publication date. The information is subject to change without notice. The information in this publication is provided as is. EMC Corporation makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any EMC software described in this publication requires an applicable software license. EMC 2, EMC, EMC VNX, EMC Unisphere, and the EMC logo are registered trademarks or trademarks of EMC Corporation in the United States and other countries. All other trademarks used herein are the property of their respective owners. For the most up-to-date listing of EMC product names, see EMC Corporation Trademarks on EMC.com. Storage Configuration Best Practices for SAP HANA TDI on EMC VNX Part Number H Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
3 Contents Contents Executive summary... 4 Introduction... 5 VNX storage configuration overview... 5 Configuring VNX storage with EMC Unisphere for VNX Accessing VNX storage from the SAP HANA nodes Conclusion References Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 3
4 Executive summary Executive summary Business case Many customers seek solutions to fulfill the requirements of an industrialized data center. The SAP High performance Analytics Appliance (HANA) in-memory computing platform, along with EMC enterprise storage, extends the possibilities for enterprises. These data centers, whether they run traditional SAP applications, including SAP HANA, or non-sap applications, must provide the following: Efficiently managed availability, capacity, performance, and health in the SAP landscape High availability and application mobility Disaster recovery Data protection By default, an SAP HANA appliance includes integrated storage, compute, and network components. SAP has defined key performance indicators (KPIs) for storage subsystems, such as I/O throughput and latency, to ensure that the overall infrastructure forms an environment ready for HANA. You also can deploy SAP HANA appliances using a Tailored Data Center Integration (TDI) approach. With this approach, you can connect certified servers to existing enterprise storage systems. This reduces the time-to-value, risk, and costs of an overall HANA adoption. Using the SAP HANA hardware configuration and check tool (hwcct), EMC did extensive testing on the VNX series unified storage system in accordance with the SAP certification scenario HANA-HWC-ES-1.0. Based on these tests, this solution guide describes a VNX storage configuration that meets SAP performance requirements (the SAP HANA TDI KPIs for data throughput and latency) and ensures the highest availability for database persistence on disk. Note: The VNX configuration requirements described in this paper apply only to production HANA appliances. Non-production HANA appliances, which do not have to meet the KPIs, can be deployed in TDI environments when the storage meets the HANA capacity requirements. SAP recommends that TDI customers run the hwcct tool in their production environment to ensure that the customer-specific HANA TDI implementation also meets the SAP performance criteria. Only hwcct tests based on the HANA-HWC-ES-1.0 certification scenario will meet the SAP performance KPIs. For more information about the certification scenarios, refer to SAP Note This solution guide also includes step-by-step instructions for configuring SAP HANA storage devices on a VNX array. 4 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
5 Introduction Introduction Purpose Until now, customers who used the SAP HANA appliance model experienced the following limitations: Limited flexibility for servers and storage Inability to use existing data center infrastructure and operational processes Fixed sizes for storage capacities This solution guide describes a solution that uses SAP HANA in a TDI deployment scenario for EMC VNX enterprise storage. This solution reduces hardware and operational costs, lowers risks, and increases hardware vendor flexibility. All configuration recommendations in this document are based on the performance tests and results used to meet the SAP KPIs for SAP HANA TDI. Scope Audience We value your feedback! This document provides best practices and tips for deploying the SAP HANA database on VNX series unified storage systems and describes the following: Key solution technologies Key business benefits of using VNX storage systems with SAP HANA How to configure VNX storage with EMC Unisphere for VNX How to access VNX storage from the SAP HANA nodes This solution guide is intended for system integrators, systems or storage administrators, customers, partners, and members of EMC Global Services who need to configure a VNX storage array to be used in a TDI environment for SAP HANA. EMC and the authors of this document welcome your feedback on the solution and the solution documentation. Contact EMC.Solution.Feedback@emc.com with your comments. Authors: Werner Katzenberger, Aighne Kearney. VNX storage configuration overview The specific SAP HANA I/O workload, which can be simulated using the SAP HANA hardware configuration and check tool (hwcct) with the HANA-HWC-ES 1.0 scenario, requires special considerations for the configuration of persistence for data and log volumes on VNX storage arrays. The VNX system delivers the high performance required for the persistent storage of an SAP HANA database. The I/O workload on SAP HANA has two major components: Random I/O on the data volume Sequential I/O on the log volume Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 5
6 VNX storage configuration overview SAP HANA uses different block sizes for log volumes and data volumes: I/O for log volumes uses 4 KB, 16 KB, and 1 MB block sizes. I/O for data volumes uses 4 KB, 16 KB, 64 KB, 1 MB, 16 MB, and 64 MB block sizes. VNX models certified for HANA TDI Figure 1 shows the VNX models certified by SAP to be used in an SAP HANA TDI environment. They are: EMC VNX5400 EMC VNX5600 EMC VNX5800 EMC VNX7600 EMC VNX8000 Figure 1. EMC VNX series unified storage systems certified for SAP HANA TDI Note: EMC VNX5200 has not been tested for the SAP HANA TDI certification of the VNX series unified storage systems. Depending on the number of HANA nodes used on a certified VNX array and the specific performance requirements of HANA, certain configurations require the array to be dedicated to the SAP HANA appliance and not used for other purposes. VNX series scalability with HANA on page 10 provides further details on scalability and limitations. VNX storage processor connectivity for the HANA persistence VNX is a unified array providing block and file connectivity. Even though file storage can be used in a HANA environment for different purposes (such as PXE-boot, shared file systems, and so on), the SAP TDI certification of the VNX series array applies only to block Fibre Channel (FC)-attached HANA persistence (data and log). The block connectivity for the SAP HANA persistence requires block EMC UltraFlex TM I/O modules on the storage processors with 4 x 8 GB/s FC ports. 6 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
7 VNX storage configuration overview Each HANA node must connect to a minimum of two FC ports on each storage processor. Figure 2 shows the recommended FC port connectivity on an UltraFlex I/O module in a storage processor. Figure 2. Recommended FC port connectivity VNX series scalability with HANA provides details about the number of I/O modules and ports required per VNX array. VNX Data Mover connectivity for the HANA shared file system In an SAP HANA scale-out deployment, a shared file system must be mounted on all nodes of the scale-out installation. This file system is used for the SAP HANA installation. The VNX unified array is perfectly suited to deliver file services in addition to the FC block connectivity on the storage processors. Although SAP HANA has no specific performance requirements for the shared file system, EMC recommends using 10 GbE interfaces with one active and one standby Data Mover. Disk configuration for HANA EMC recommends the following disk configuration in a VNX for SAP HANA: 10,000 rpm or 15,000 rpm SAS disks Two RAID groups in a RAID5 8+1 configuration (9 disks) for 1 or 2 HANA worker nodes with striped meta devices across the two RAID groups, as shown in Figure 3. Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 7
8 VNX storage configuration overview Figure 3. Recommended meta volume configuration Disk size depends on capacity requirements, as shown in Table 1. Note: Only meta devices on RAID groups meet the SAP performance requirements for SAP HANA TDI deployments in the HANA-HWC-ES-1.0 certification scenario. SAP HANA capacity requirements for persistence Table 1 shows the usable capacity of a single RAID group in a RAID 5 (8+1) configuration based on the per-disk size. Table 1. Disk pool capacity for different disk sizes Disk size Usable capacity per RAID group RAID5 (8+1) 300 GB 2,145 GB 600 GB 4,288 GB 900 GB 6,560 GB 8 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
9 VNX storage configuration overview Note: Even though the usable capacity of a RAID group may exceed the required capacity for the HANA persistence, EMC strongly recommends not using fewer disks or a different RAID configuration. Otherwise, the SAP HANA performance requirements will not be met. Capacity considerations In general, the capacity required for the SAP HANA persistence on disk depends on the in-memory database size and the RAM size of the HANA servers. Every SAP HANA customer must perform memory and CPU sizing as the first step in sizing an SAP HANA deployment. For new SAP HANA implementations, you can determine the memory and CPU requirements for an SAP HANA system using the HANA version of the SAP Quick Sizer tool, which is available on the SAP Service Marketplace website. For systems that are migrating to SAP HANA, SAP provides tools and reports for proper HANA memory sizing. After memory requirements have been determined, you can calculate the disk capacity requirements by using the sizing rules provided by SAP in their SAP HANA Storage Requirements white paper. HANA persistence LUNs Each SAP HANA worker node requires two LUNs for the database persistence, a data LUN and a log LUN. Both LUNs must be created as meta-luns with one member from two RAID groups, as shown in Figure 3. A best practice is to ensure that data and log LUNs are assigned to different storage processors for example, the data LUN is owned by storage processor A (SP-A) and the log LUN is owned by SP-B. The following formulas were used for the persistence in the certification tests and in the configuration examples in Configuring VNX storage with EMC Unisphere for VNX: Data size = RAM size * 3 Log size = RAM size * 1 For the current sizing requirements, refer to the latest version of the SAP HANA Storage Requirements white paper. HANA shared file system In an SAP HANA scale-out implementation, the SAP HANA database binaries must be installed on a shared file system. The VNX unified array can provide and export an NFS share for this purpose. A specific performance requirement for this share does not exist. You can create the underlying block LUNs from a separate disk pool by using the Unisphere wizards for file. In the certification tests, we used the following formula to determine the size of the shared file system: # of HANA nodes * RAM size of a single node For the current sizing requirements, refer to the latest version of the SAP HANA Storage Requirements white paper. Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 9
10 VNX storage configuration overview VNX series scalability with HANA The following tables summarize the connectivity and capacity requirements for SAP HANA for each VNX model: Table 2 Scalability of VNX5400 Table 3 Scalability of VNX5600 Table 4 Scalability of VNX5800 Table 5 Scalability of VNX7600 Table 6 Scalability of VNX8000 These tables can be used as a reference for planning SAP HANA TDI with VNX deployments. Depending on the number of HANA nodes deployed on a specified VNX model, you can share the array with other applications. Usually, if you use more than half of the maximum supported nodes per array, the array must be dedicated to SAP HANA and cannot be shared with other applications. For example, on a VNX5800, which supports a maximum of six HANA nodes, you can run up to three HANA nodes and share the array with other applications. If you are running more than three HANA nodes, the array must be dedicated to the HANA application to ensure that the array meets the HANA performance requirements. The Total number of disks for the HANA persistence table column does not include the additional disks required for the HANA shared file system. Neither does it include any other capacity that must be provided by the VNX system, such as boot devices, operation systems, and so on. Use the SUSE Write performance file patch for increasing I/O operations on XFS to achieve the best performance and full scalability of the VNX arrays. Use the following or greater kernel from SUSE: The HANA nodes numbers listed in the following tables represent an initial guideline to help you determine the VNX array for an existing or planned HANA environment. The actual number of production HANA nodes that can be connected to a VNX might be different. EMC recommends running regular HANA health checks, such as the HANA configuration mini checks described in SAP Note and SAP Note , to verify the performance of the underlying storage environment. Note: A careful performance analysis of a VNX storage system with existing applications is required before a production SAP HANA can be deployed. Table 2. Scalability of VNX5400 Number of nodes Required UltraFlex IO modules per SP/array Required FC ports per SP/array Number of RAID groups required Total number of disks for the HANA persistence Is array sharing possible? 1-2 1/ 2 2/ Yes 3-4 1/2 4/ Yes 5 2/4 6/ Yes 10 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
11 VNX storage configuration overview Number of nodes Required UltraFlex IO modules per SP/array Required FC ports per SP/array Number of RAID groups required Total number of disks for the HANA persistence Is array sharing possible? 6 2/4 6/ No 7-8 2/4 8/ No /6 10/ No Note: VNX5400 supports a maximum of 10 HANA nodes. Table 3. Scalability of VNX5600 Number of nodes Required UltraFlex IO modules per SP/array Required FC ports per SP/array Number of RAID groups required Total number of disks for the HANA persistence Is array sharing possible? 1-2 1/ 2 2/ Yes 3-4 1/2 4/ Yes 5 2/4 6/ Yes 6 2/4 6/ No 7-8 2/4 8/ No /6 10/ No Note: VNX5600 supports a maximum of 10 HANA nodes. Table 4. Scalability of VNX5800 Number of nodes Required UltraFlex IO modules per SP/array Required FC ports per SP/array Number of RAID groups required Total number of disks for the HANA persistence Array sharing possible? 1-2 1/ 2 2/ Yes 3-4 1/2 4/ Yes 5 2/4 6/ Yes 6 2/4 6/ No 7-8 2/4 8/ No /6 10/ No Note: VNX5800 supports a maximum of 10 HANA nodes. Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 11
12 Configuring VNX storage with EMC Unisphere for VNX Table 5. Scalability of VNX7600 Number of nodes Required UltraFlex IO modules per SP/array Required FC ports per SP/array Number of pools or RAID groups required Total number of disks for the HANA persistence Is array sharing possible? 1-2 1/ 2 2/ Yes 3-4 1/2 4/ Yes 5-6 2/4 6/ Yes 7-8 2/4 8/ No /6 10/ No /6 12/ No Note: VNX7600 supports a maximum of 12 HANA nodes. Table 6. Scalability of VNX8000 Number of nodes Required UltraFlex IO modules per SP/array Required FC ports per SP/array Number of RAID groups required Total number of disks for the HANA persistence Array sharing possible? 1-2 1/ 2 2/ Yes 3-4 1/2 4/ Yes 5-6 2/4 6/ Yes 7-8 2/4 8/ Yes /6 10/ No /6 12/ No /8 14/ No /8 16/ No Note: VNX8000 supports a maximum of 16 HANA nodes. Configuring VNX storage with EMC Unisphere for VNX You can use Unisphere for VNX for all the storage configuration tasks required to create the HANA storage devices. Use the step-by-step instructions in the following sections as an example. Create RAID groups For every SAP HANA worker node, use two RAID groups in a RAID5 (8+1) configuration with nine disks. 12 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
13 Configuring VNX storage with EMC Unisphere for VNX To create a RAID group: 1. Select Storage > Storage Pools > RAID Groups and click Create. 2. Select RAID5 in RAID Configuration and let the array automatically select 9 (Recommended) disks, as shown in Figure 4. Figure 4. Create a RAID Group 3. Click OK to create the RAID group. Create HANA persistence for data and log Each HANA persistent data or log LUN must be created as a striped meta-lun with two LUNs in two RAID Groups, as shown in Figure 3. To create HANA persistence for data and log of two HANA worker nodes, use the following steps: 1. After the RAID group is ready, right-click the disk RAID group and select Create LUN from the context menu. 2. Under General, as shown in Figure 5, select the User Capacity for the LUN, which must be half of the final DATA or LOG size, create two LUNs of this size, and type the Name of the LUNs and a Starting ID of 1. Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 13
14 Configuring VNX storage with EMC Unisphere for VNX Note: You must determine the final capacity of the data and log metaluns using the SAP HANA Storage Requirements white paper. In the following examples, we used 512 GB for the log LUN and 1.5 TB for the data LUN. Figure 5. Select General properties for the LUN In this example, the system will create two LUNs with names LOG_RG8_1 and LOG_R8_2. Repeat this step on the same RAID group and create two LUNs for DATA. Then select the second RAID group and create two LUNs for LOG and two LUNs for DATA. You should have the following single LUNs: o o RAID group 1 LOG_RG8_1, LOG_RG8_2, DATA_RG8_1, DATA_RG8_2 RAID group 2 LOG RG9_1, LOG_RG9_2, DATA_RG9_1, DATA_RG9_2 3. Select Storage > LUNs. The new LUNs appear, as shown in Figure Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
15 Configuring VNX storage with EMC Unisphere for VNX Figure 6. Single LUNs 4. To create a metalun, right-click on the first LUN (DATA_RG8_1, in this example) and click Expand. The Expand Storage Wizard appears, as shown in Figure 7. Figure 7. Expand Storage Wizard 5. Select an Expansion Type of Striping, and then click Next, as shown in Figure 8. Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 15
16 Configuring VNX storage with EMC Unisphere for VNX Figure 8. Select an expansion type 6. Select the LUN from the other RAID group that you want to use to expand the base LUN, and then click Next, as shown in Figure 9. Figure 9. Select Unused LUNs To specify a new LUN capacity, select the Maximum capacity, and then click Next, as shown in Figure Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
17 Configuring VNX storage with EMC Unisphere for VNX Figure 10. Specify a new LUN capacity 7. To specify new LUN settings, select a Default Owner, accept the default values for Element Size and Alignment Offset, and then click Next, as shown in Figure 11. Figure 11. Specify new LUN settings 8. Review the Summary settings and click Finish to create the metalun, as shown in Figure 12: Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 17
18 Configuring VNX storage with EMC Unisphere for VNX Figure 12. Summary Repeat the steps for the LOG and the DATA metaluns and ensure that both LUNs are bound to different storage processors for the default owner. If you create LUNs for multiple HANA nodes, distribute data and log LUNs across the storage processors. For example, if you create six data LUNs and six log LUNs, ensure that each storage processor owns three data LUNs and three log LUNs. Base the size of the LUNs on the requirements in the SAP HANA Storage Requirements white paper. Register initiators Each HANA node must have two host bus adapters (HBAs) that are properly zoned to the FC ports of the VNX I/O modules. After the HANA nodes are started, the initiators are visible to the VNX and must be registered. Assign the World Wide Name (WWN) initiator to the corresponding HANA node. To register initiators: 1. Select Hosts > Initiators. 2. Click an initiator that is not yet registered and select Register. 3. Select an Initiator Type of CLARiiON/VNX and a Failover Mode 1 of Active- Passive (PNR), as shown in Figure 13. If this is the first initiator for the server, select a new host and specify a hostname and IP address. Otherwise, select the corresponding server from the list of existing hosts. 18 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
19 Accessing VNX storage from the SAP HANA nodes Figure 13. Select initiator and host agent information 4. Click OK to save your changes. Repeat these steps for all unregistered initiators. Create storage groups To create storage groups: 1. Select Hosts > Storage Groups, and click Create, as shown in Figure 14. Figure 14. Create a storage group 2. Select a storage group name, for example, sghana01, and click Apply. 3. Click Connect LUNs and add all persistence LUNs to the storage group. Note: Do not use 0 as the host LUN ID. 4. After all LUNs are connected, connect the host that has previously been registered to this storage group. Accessing VNX storage from the SAP HANA nodes The SAP HANA database requires a Linux SUSE SLES-11 operating system on the HANA nodes. To access the VNX block devices from the HANA nodes, ensure that proper zoning was done in the SAN so that all HBAs (or vhbas) of the HANA nodes have access to the FC ports on the I/O module, as described in the previous sections. Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 19
20 Accessing VNX storage from the SAP HANA nodes Note: The SAP HANA database also supports the Red Hat Enterprise Linux (RHEL) 6.5 operating system. Enable native Linux multipathing (DM-MPIO) To access the block devices from the HANA nodes, first enable native Linux multipathing. The Linux Storage Administration Guide provides information on how to enable DM-MPIO on a HANA node. Note: The commands below are based on the SUSE SLES-11 operating system. To enable native Linux multipathing: 1. Create an /etc/multipath.conf file with the correct parameters to be set for the VNX system. You can use the following code sample for RAID group LUNs: defaults { user_friendly_names no } devices { device { vendor "DGC" product ".*" product_blacklist "LUNZ" features "0" hardware_handler "1 emc" path_selector "round-robin 0" path_grouping_policy group_by_prio failback immediate rr_weight uniform no_path_retry 5 rr_min_io 1 path_checker emc_clariion prio emc flush_on_last_del yes fast_io_fail_tmo off dev_loss_tmo 120 } } 2. After creating the configuration file, restart the multipath daemon to activate the settings and rescan the new devices: $ rescan-scsi-bus.sh $ service multipathd force-reload The HANA persistence device should be visible. 3. Type the following command to verify that all devices are present and each device has four active paths: server01:~ # multipath -ll fee517e411 dm-0 DGC,VRAID size=512g features='1 queue_if_no_path' hwhandler='1 emc' wp=rw -+- policy='service-time 0' prio=4 status=active 20 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
21 Accessing VNX storage from the SAP HANA nodes - 1:0:1:1 sde 8:64 active ready running `- 2:0:7:1 sdw 65:96 active ready running `-+- policy='service-time 0' prio=1 status=enabled - 1:0:0:1 sdb 8:16 active ready running `- 2:0:6:1 sdt 65:48 active ready running ef712e617e411 dm-1 DGC,VRAID size=1.5t features='1 queue_if_no_path' hwhandler='1 emc' wp=rw -+- policy='service-time 0' prio=4 status=active - 1:0:0:2 sdc 8:32 active ready running `- 2:0:6:2 sdu 65:64 active ready running `-+- policy='service-time 0' prio=1 status=enabled - 1:0:1:2 sdf 8:80 active ready running `- 2:0:7:2 sdx 65:112 active ready running If all devices are visible, create file systems on the block devices. Format block devices using the XFS file system EMC recommends using XFS as the file system for the HANA block devices. To format a block device with the XFS file system, type the following command on the HANA node: $ mkfs.xfs /dev/mapper/ Note: Run this command for all block devices. Mount block devices In a SAP HANA scale-out environment with worker and standby nodes, the SAP HANA Storage Connector API for Fibre Channel (fcclient.py) mounts and unmounts the devices to the HANA nodes. In addition to mounting the devices, the Storage Connector API also writes SCSI-3 PGR reservations to the devices using the Linux sg_persist command. This is called I/O fencing. It ensures that only one HANA node at a time has access to a set of data and log devices. SAP HANA global.ini file The Storage Connector API is controlled in the storage section of the SAP HANA global.ini file. This section of the file contains entries for the block devices with optional mount options. For the XFS devices, use the following XFS mount options: relatime nobarrier (approved from SAP) only for Log devices inode64 This is an example of a global.ini file: [persistence] basepath_datavolumes=/hana/data/ana basepath_logvolumes=/hana/log/ana use_mountpoints = yes Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 21
22 Conclusion [storage] ha_provider = hdb_ha.fcclient partition_*_* prtype = 5 partition_*_data mountoptions = -o relatime,inode64 partition_*_log mountoptions = -o relatime,inode64,nobarrier partition_1_data wwid = partition_1_log wwid = partition_2_data wwid = partition_2_log wwid = partition_3_data wwid = partition_3_log wwid = Conclusion Using EMC enterprise storage, SAP HANA, and TDI, EMC developed the concept of running SAP HANA in a VNX storage system. This concept provides many benefits, including reducing hardware and operational costs, lowering risks, and increasing hardware vendor flexibility, for SAP as well as nonsap applications. Customers can now integrate HANA into their existing data center infrastructure. An essential characteristic of this solution is the use of shared enterprise storage. This allows customers to rely on already available multisite concepts to benefit from established automation and operations processes. Customers can now transition easily from the appliance model to the new TDI architecture with SAP HANA while relying on EMC solutions and services to minimize risk. 22 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
23 References References EMC documentation The following documentation on EMC.com or EMC Online Support provides additional relevant information. Access to these documents depends on your login credentials. If you do not have access to a document, contact your EMC representative. The EMC VNX series unified storage systems documentation set contains the hardware platform guides for the VNX5400, VNX5600, VNX5800, VNX7600, and VNX8000 storage arrays EMC Cloud Enabled Infrastructure for SAP: Business White Paper EMC Cloud Enabled Infrastructure for SAP: Foundation Bundle SAP documentation The following documentation on the SAP website provides additional relevant information about SAP HANA: SAP HANA Server Installation and Update Guide SAP HANA TDI - Storage Requirements Certified SAP HANA Hardware Directory - EMC Enterprise Storage Web resources SAP HANA Platform SAP HANA One SAP HANA Enterprise Cloud Overview - SAP HANA tailored data center integration The following documents require an SAP username and password. Best practice documents/white papers Sizing Approaches for SAP HANA Lessons Learned Enterprise Storage Architecture Planning Guide Elements of a Software Change Management Strategy Technical Deployment Options for SAP Systems with SAP HANA Notes: Deployment options Note Multiple SAP HANA databases on one appliance Note Support for multiple applications on SAP HANA Note BW on SAP HANA; Landscape deployment planning Note SAP HANA Guidelines for SLES Operating System Note SAP HANA Guidelines for RedHat Enterprise Linux (RHEL) Note SQL statement collection for SAP HANA Storage Configuration Best Practices for SAP HANA TDI on EMC VNX 23
24 References Note FAQ: SAP HANA I/O Analysis Notes: Virtualization Note SAP HANA running on VMware vsphere VMs 24 Storage Configuration Best Practices for SAP HANA TDI on EMC VNX
NEC Storage M series for SAP HANA Tailored Datacenter Integration
NEC Storage M series for SAP HANA Tailored Datacenter Integration (NEC Storage M110/M310/M510/M710) Configuration and Best Practice Guide NEC June 2015 Copyright 2015 NEC Corporation. All Rights Reserved.
More informationNEC Storage M series for SAP HANA Tailored Datacenter Integration Configuration and Best Practice Guide
NEC Storage M series for SAP HANA Tailored Datacenter Integration Configuration and Best Practice Guide (M120/M320/M320F/M110/M310/M310F/M510/M710/M710F) August, 2018 NEC Copyright 2018 NEC Corporation.
More informationLINUX IO performance tuning for IBM System Storage
LINUX IO performance tuning for IBM System Storage Location of this document: http://www.ibm.com/support/techdocs/atsmastr.nsf/webindex/wp102584 Markus Fehling Certified IT specialist cross systems isicc@de.ibm.com
More informationSTORAGE CONFIGURATION BEST PRACTICES FOR SAP HANA TAILORED DATA CENTER INTEGRATION ON DELL EMC COMPELLENT STORAGE SYSTEMS
STORAGE CONFIGURATION BEST PRACTICES FOR SAP HANA TAILORED DATA CENTER INTEGRATION ON DELL EMC COMPELLENT STORAGE SYSTEMS November 2017 Abstract This solution guide describes best practices for SAP HANA
More informationDell EMC SAN Storage with Video Management Systems
Dell EMC SAN Storage with Video Management Systems Surveillance October 2018 H14824.3 Configuration Best Practices Guide Abstract The purpose of this guide is to provide configuration instructions for
More informationSTORAGE CONFIGURATION BEST PRACTICES FOR SAP HANA TDI ON DELL EMC UNITY STORAGE SYSTEMS
STORAGE CONFIGURATION BEST PRACTICES FOR SAP HANA TDI ON DELL EMC UNITY STORAGE SYSTEMS August 2017 ABSTRACT This solution guide describes storage best practices for SAP HANA in Tailored Data Center (TDI)
More informationThe Contents and Structure of this Manual. This document is composed of the following four chapters.
Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000
More informationSAP HANA Operation Expert Summit PLAN - Hardware Landscapes. Addi Brosig, SAP HANA Product Management May 2014
SAP HANA Operation Expert Summit PLAN - Hardware Landscapes Addi Brosig, SAP HANA Product Management May 2014 Disclaimer This presentation outlines our general product direction and should not be relied
More informationSurveillance Dell EMC Storage with FLIR Latitude
Surveillance Dell EMC Storage with FLIR Latitude Configuration Guide H15106 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published June 2016 Dell believes the information
More informationSAP HANA on NetApp E-Series with Fibre Channel Protocol
Technical Report SAP HANA on NetApp E-Series with Fibre Channel Protocol Configuration Guide Adolf Hohl, Bernd Herth, NetApp July 2015 TR-4296 Abstract This document describes how to deploy HANA on NetApp
More informationSurveillance Dell EMC Storage with Digifort Enterprise
Surveillance Dell EMC Storage with Digifort Enterprise Configuration Guide H15230 REV 1.1 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published August 2016 Dell believes the
More informationVideo Surveillance EMC Storage with Godrej IQ Vision Ultimate
Video Surveillance EMC Storage with Godrej IQ Vision Ultimate Sizing Guide H15052 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published May 2016 EMC believes the information
More informationSAP HANA on Dell EMC VxRail Hyper-Converged Infrastructure
SAP HANA on Dell EMC VxRail Hyper-Converged Infrastructure December 2018 H17317.2 Abstract This validation guide provides best-practice storage and configuration guidelines for a Dell EMC VxRail hyper-converged
More informationEMC Business Continuity for Microsoft Applications
EMC Business Continuity for Microsoft Applications Enabled by EMC Celerra, EMC MirrorView/A, EMC Celerra Replicator, VMware Site Recovery Manager, and VMware vsphere 4 Copyright 2009 EMC Corporation. All
More informationEMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE
White Paper EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE EMC XtremSF, EMC XtremCache, EMC Symmetrix VMAX and Symmetrix VMAX 10K, XtremSF and XtremCache dramatically improve Oracle performance Symmetrix
More informationSAP HANA SPS 10 - What s New? Scale-Out, High Availability and Disaster Recovery
SAP HANA SPS 10 - What s New? Scale-Out, High Availability and Disaster Recovery (Delta from SPS 09 to SPS 10) SAP HANA Product Management June, 2015 2014 SAP AG or an SAP affiliate company. All rights
More informationDATA PROTECTION IN A ROBO ENVIRONMENT
Reference Architecture DATA PROTECTION IN A ROBO ENVIRONMENT EMC VNX Series EMC VNXe Series EMC Solutions Group April 2012 Copyright 2012 EMC Corporation. All Rights Reserved. EMC believes the information
More informationStorage Configuration Best Practices for SAP HANA TDI on Dell EMC PowerMax Arrays
Storage Configuration Best Practices for SAP HANA TDI on Dell EMC PowerMax Arrays August 2018 H17290 Abstract This validation guide describes storage configuration best practices for SAP HANA in Tailored
More informationHYPER-UNIFIED STORAGE. Nexsan Unity
HYPER-UNIFIED STORAGE Nexsan Unity Multipathing Best Practices Guide NEXSAN 25 E. Hillcrest Drive, Suite #150 Thousand Oaks, CA 9160 USA Printed Wednesday, January 02, 2019 www.nexsan.com Copyright 2010
More informationSAP HANA tailored data center integration Frequently Asked Questions
SAP HANA tailored data center integration Frequently Asked Questions Version 1.0 Last update: 13 May, 2013 TABLE OF CONTENTS GENERAL INFORMATION... 3 1. What is SAP HANA tailored data center integration?
More informationBUSINESS CONTINUITY BEST PRACTICES FOR SAP HANA TAILORED DATACENTER INTEGRATION
BUSINESS CONTINUITY BEST PRACTICES FOR SAP HANA TAILORED DATACENTER INTEGRATION On EMC VNX Storage Systems with EMC MirrorView and EMC SnapView EMC Solutions Abstract This white paper introduces EMC VNX
More informationSAP HANA on NetApp FAS Systems with Fibre Channel Protocol
Technical Report SAP HANA on NetApp FAS Systems with Fibre Channel Protocol Configuration Guide Nils Bauer and Bernd Herth, NetApp November 2017 TR-4384 Abstract The NetApp FAS product family has been
More informationSurveillance Dell EMC Storage with Milestone XProtect Corporate
Surveillance Dell EMC Storage with Milestone XProtect Corporate Sizing Guide H14502 REV 1.5 Copyright 2014-2018 Dell Inc. or its subsidiaries. All rights reserved. Published January 2018 Dell believes
More informationDell EMC Ready System for VDI on VxRail
Dell EMC Ready System for VDI on VxRail Citrix XenDesktop for Dell EMC VxRail Hyperconverged Appliance April 2018 H16968.1 Deployment Guide Abstract This deployment guide provides instructions for deploying
More informationDell EMC Ready System for VDI on XC Series
Dell EMC Ready System for VDI on XC Series Citrix XenDesktop for Dell EMC XC Series Hyperconverged Appliance March 2018 H16969 Deployment Guide Abstract This deployment guide provides instructions for
More informationSurveillance Dell EMC Storage with Bosch Video Recording Manager
Surveillance Dell EMC Storage with Bosch Video Recording Manager Sizing and Configuration Guide H13970 REV 2.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published December
More informationEMC Backup and Recovery for Microsoft SQL Server
EMC Backup and Recovery for Microsoft SQL Server Enabled by Microsoft SQL Native Backup Reference Copyright 2010 EMC Corporation. All rights reserved. Published February, 2010 EMC believes the information
More informationFUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-
FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations that need to be
More informationCopyright 2015 EMC Corporation. All rights reserved. Published in the USA.
This Reference Architecture Guide describes, in summary, a solution that enables IT organizations to quickly and effectively provision and manage Oracle Database as a Service (DBaaS) on Federation Enterprise
More informationEMC Performance Optimization for VMware Enabled by EMC PowerPath/VE
EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE Applied Technology Abstract This white paper is an overview of the tested features and performance enhancing technologies of EMC PowerPath
More informationDell EMC SAP HANA Appliance Backup and Restore Performance with Dell EMC Data Domain
Dell EMC SAP HANA Appliance Backup and Restore Performance with Dell EMC Data Domain Performance testing results using Dell EMC Data Domain DD6300 and Data Domain Boost for Enterprise Applications July
More informationSurveillance Dell EMC Storage with Cisco Video Surveillance Manager
Surveillance Dell EMC Storage with Cisco Video Surveillance Manager Configuration Guide H14001 REV 1.1 Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2015 Dell believes
More informationEMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V
IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes the steps required to deploy a Microsoft Exchange Server 2013 solution on
More informationVideo Surveillance EMC Storage with Digifort Enterprise
Video Surveillance EMC Storage with Digifort Enterprise Sizing Guide H15229 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published August 2016 EMC believes the information
More informationUsing EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x
Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Application notes Abstract These application notes explain configuration details for using Infortrend EonStor DS Series iscsi-host
More informationIBM System Storage Architecture and Configuration Guide for SAP HANA Tailored Datacenter Integration
IBM System Storage Architecture and Configuration Guide for SAP HANA Tailored Datacenter Integration location of this document: http://www-03.ibm.com/support/techdocs/atsmastr.nsf/webindex/wp102347 isicc@de.ibm.com
More informationAdaptive Flash Array for Use with SAP HANA Deployment Guide
Adaptive Flash Array for Use with SAP HANA Deployment Guide Contents Introduction...4 Audience...4 Architecture Overview...5 Hardware Components...5 Software and Firmware Components...6 Deployment...8
More informationConfiguring and Managing Virtual Storage
Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks
More informationMaintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS
Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Applied Technology Abstract This white paper describes tests in which Navisphere QoS Manager and VMware s Distributed
More informationUsing Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2
Using Dell EqualLogic and Multipath I/O with Citrix XenServer 6.2 Dell Engineering Donald Williams November 2013 A Dell Deployment and Configuration Guide Revisions Date November 2013 Description Initial
More informationConfiguration Guide -Server Connection-
FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Citrix XenServer This page is intentionally left blank. Preface This manual briefly explains the operations
More informationEMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA
EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA Version 4.0 Configuring Hosts to Access VMware Datastores P/N 302-002-569 REV 01 Copyright 2016 EMC Corporation. All rights reserved.
More informationDell EMC Ready Architectures for VDI
Dell EMC Ready Architectures for VDI Designs for Citrix XenDesktop and XenApp for Dell EMC XC Family September 2018 H17388 Deployment Guide Abstract This deployment guide provides instructions for deploying
More informationSecuring VSPEX VMware View 5.1 End- User Computing Solutions with RSA
Design Guide Securing VSPEX VMware View 5.1 End- User Computing Solutions with RSA VMware vsphere 5.1 for up to 2000 Virtual Desktops EMC VSPEX Abstract This guide describes required components and a configuration
More informationNetApp SANtricity Cloud Connector 3.1
Technical Report NetApp SANtricity Cloud Connector 3.1 Robert Stankey, Janelle Sperry, NetApp June 2018 TR-4658 In partnership with Abstract NetApp SANtricity Cloud Connector 3.1 is a host-based Linux
More informationBUSINESS CONTINUITY AND DISASTER RECOVERY WITH EMC XTREMIO FOR SAP HANA TAILORED DATA CENTER INTEGRATION
BUSINESS CONTINUITY AND DISASTER RECOVERY WITH EMC XTREMIO FOR SAP HANA TAILORED DATA CENTER INTEGRATION Enabled by EMC RecoverPoint asynchronous snap-based replication EMC Solutions Abstract This solution
More informationVideo Surveillance EMC Storage with LENSEC Perspective VMS
Video Surveillance EMC Storage with LENSEC Perspective VMS Sizing Guide H14768 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published March, 2016 EMC believes the information
More informationEMC CLARiiON Backup Storage Solutions
Engineering White Paper Backup-to-Disk Guide with Computer Associates BrightStor ARCserve Backup Abstract This white paper describes how to configure EMC CLARiiON CX series storage systems with Computer
More informationHere is Your Customized Document
Here is Your Customized Document Your Configuration is: Manage LUNs Model - VNX5300 Storage Type - VNX for Block (SAN) Connection Type - Fibre Channel Switch or Boot from SAN Operating System - ESX Server
More informationSAP HANA TDI on Dell EMC Isilon All-Flash Scale-Out NAS
SAP HANA TDI on Dell EMC Isilon All-Flash Scale-Out NAS Best Practices for Isilon F800 Storage Configuration December 2018 H17525 Abstract This validation guide describes storage configuration best practices
More informationDell EMC vsan Ready Nodes for VDI
Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware
More informationMaintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS
Maintaining End-to-End Service Levels for VMware Virtual Machines Using VMware DRS and EMC Navisphere QoS Applied Technology Abstract This white paper describes tests in which Navisphere QoS Manager and
More informationEMC CLARiiON CX3-40. Reference Architecture. Enterprise Solutions for Microsoft Exchange Enabled by MirrorView/S
Enterprise Solutions for Microsoft Exchange 2007 EMC CLARiiON CX3-40 Metropolitan Exchange Recovery (MER) for Exchange in a VMware Environment Enabled by MirrorView/S Reference Architecture EMC Global
More information2 to 4 Intel Xeon Processor E v3 Family CPUs. Up to 12 SFF Disk Drives for Appliance Model. Up to 6 TB of Main Memory (with GB LRDIMMs)
Based on Cisco UCS C460 M4 Rack Servers Solution Brief May 2015 With Intelligent Intel Xeon Processors Highlights Integrate with Your Existing Data Center Our SAP HANA appliances help you get up and running
More informationMIGRATING TO DELL EMC UNITY WITH SAN COPY
MIGRATING TO DELL EMC UNITY WITH SAN COPY ABSTRACT This white paper explains how to migrate Block data from a CLARiiON CX or VNX Series system to Dell EMC Unity. This paper outlines how to use Dell EMC
More informationEMC VSPEX END-USER COMPUTING
IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon View 5.3 and VMware vsphere for up to 2,000 Virtual Desktops Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract
More informationEMC VSPEX END-USER COMPUTING
IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7 and Microsoft Hyper-V for up to 2,000 Virtual Desktops Enabled by EMC Next-Generation VNX and EMC Powered Backup EMC VSPEX Abstract
More informationEMC CLARiiON CX3 Series FCP
EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com Copyright 2008
More informationDevice Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.1 release notes
Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.1 release notes April 2010 H Legal and notice information Copyright 2009-2010 Hewlett-Packard Development Company, L.P. Overview
More informationVideo Surveillance EMC Storage with Honeywell Digital Video Manager
Video Surveillance EMC Storage with Honeywell Digital Video Manager Sizing Guide H14748 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published February, 2016 EMC believes
More informationEMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15
EMC SAN Copy Command Line Interface (CLI) Reference P/N 069001189 REV A15 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2010 EMC Corporation.
More informationBUSINESS CONTINUITY AND DISASTER RECOVERY FOR SAP HANA TAILORED DATA CENTER INTEGRATION
BUSINESS CONTINUITY AND DISASTER RECOVERY FOR SAP HANA TAILORED DATA CENTER INTEGRATION June 2017 ABSTRACT This white paper describes how Dell EMC RecoverPoint continuous data protection provides proven
More informationEMC Integrated Infrastructure for VMware. Business Continuity
EMC Integrated Infrastructure for VMware Business Continuity Enabled by EMC Celerra and VMware vcenter Site Recovery Manager Reference Architecture Copyright 2009 EMC Corporation. All rights reserved.
More informationThe Host Server. Linux Configuration Guide. August The authority on real-time data
The Host Server Linux Configuration Guide August 2018 This guide provides configuration settings and considerations for Hosts running Linux with SANsymphony. Basic Linux storage administration skills are
More informationDell EMC Ready Architectures for VDI
Dell EMC Ready Architectures for VDI Designs for VMware Horizon 7 on Dell EMC XC Family September 2018 H17387 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware
More informationReference Architecture
EMC Solutions for Microsoft SQL Server 2005 on Windows 2008 in VMware ESX Server EMC CLARiiON CX3 Series FCP EMC Global Solutions 42 South Street Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com www.emc.com
More informationEMC ViPR Controller. Integration with VMAX and VNX Storage Systems Guide. Version REV 01
EMC ViPR Controller Version 2.3 Integration with VMAX and VNX Storage Systems Guide 302-002-075 REV 01 Copyright 2013-2015 EMC Corporation. All rights reserved. Published in USA. Published July, 2015 EMC
More informationOptimizing Quality of Service with SAP HANA on Power Rapid Cold Start
Optimizing Quality of Service with SAP HANA on Power Rapid Cold Start How SAP HANA on Power with Rapid Cold Start helps clients quickly restore business-critical operations Contents 1 About this document
More informationOnCommand Unified Manager 7.2: Best Practices Guide
Technical Report OnCommand Unified : Best Practices Guide Dhiman Chakraborty August 2017 TR-4621 Version 1.0 Abstract NetApp OnCommand Unified is the most comprehensive product for managing and monitoring
More informationEMC SAN Copy Command Line Interfaces
EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All
More informationEMC VSPEX END-USER COMPUTING
IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING VMware Horizon View 6.0 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Data Protection EMC VSPEX Abstract This describes
More informationVirtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1. Reference Architecture
Virtualizing SQL Server 2008 Using EMC VNX Series and VMware vsphere 4.1 Copyright 2011, 2012 EMC Corporation. All rights reserved. Published March, 2012 EMC believes the information in this publication
More informationSAP HANA Storage Requirements
SAP HANA Storage Requirements As an in-memory database, SAP HANA uses storage devices to save a copy of the data, for the purpose of startup and fault recovery without data loss. The choice of the specific
More informationSurveillance Dell EMC Storage with Verint Nextiva
Surveillance Dell EMC Storage with Verint Nextiva Sizing Guide H14897 REV 1.3 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published September 2017 Dell believes the information
More informationSAP HANA SPS 08 - What s New? SAP HANA Platform Lifecycle Management (Delta from SPS 07 to SPS 08) SAP HANA Product Management May, 2014
SAP HANA SPS 08 - What s New? SAP HANA Platform Lifecycle Management (Delta from SPS 07 to SPS 08) SAP HANA Product Management May, 2014 Agenda SAP HANA platform lifecycle management (lcm) service & tools
More informationEMC STORAGE FOR MILESTONE XPROTECT CORPORATE
Reference Architecture EMC STORAGE FOR MILESTONE XPROTECT CORPORATE Milestone multitier video surveillance storage architectures Design guidelines for Live Database and Archive Database video storage EMC
More informationEMC BUSINESS CONTINUITY FOR VMWARE VIEW 5.1
White Paper EMC BUSINESS CONTINUITY FOR VMWARE VIEW 5.1 EMC VNX Replicator, VMware vcenter Site Recovery Manager, and VMware View Composer Automating failover of virtual desktop instances Preserving user
More informationEMC VSPEX END-USER COMPUTING
IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.1 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Powered Backup EMC VSPEX Abstract This describes
More informationEMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH HYPER-V
IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH HYPER-V EMC VSPEX Abstract This describes, at a high level, the steps required to deploy a Microsoft Exchange 2013 organization
More informationDevice Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes
Device Mapper Multipath Enablement Kit for HP StorageWorks Disk Arrays v4.4.0 release notes Part number: AA-RWF9K-TE First edition: February 2010 Legal and notice information Copyright 2009-2010 Hewlett-Packard
More informationWhite Paper. A System for Archiving, Recovery, and Storage Optimization. Mimosa NearPoint for Microsoft
White Paper Mimosa Systems, Inc. November 2007 A System for Email Archiving, Recovery, and Storage Optimization Mimosa NearPoint for Microsoft Exchange Server and EqualLogic PS Series Storage Arrays CONTENTS
More informationSAP HANA on Dell EMC XC Appliances and XC Core Systems Best Practices Guide
SAP HANA on Dell EMC XC Appliances and XC Core Systems Best Practices Guide Abstract This document provides best-practices and configuration guidelines for Dell EMC XC Series Appliances and XC Core Systems
More informationEMC Celerra NS20. EMC Solutions for Microsoft Exchange Reference Architecture
EMC Solutions for Microsoft Exchange 2007 EMC Celerra NS20 EMC NAS Product Validation Corporate Headquarters Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2008 EMC Corporation. All rights
More informationAn Introduction to GPFS
IBM High Performance Computing July 2006 An Introduction to GPFS gpfsintro072506.doc Page 2 Contents Overview 2 What is GPFS? 3 The file system 3 Application interfaces 4 Performance and scalability 4
More informationInstalling VMware vsphere 5.1 Components
Installing VMware vsphere 5.1 Components Module 14 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks
More informationUsing EMC FAST with SAP on EMC Unified Storage
Using EMC FAST with SAP on EMC Unified Storage Applied Technology Abstract This white paper examines the performance considerations of placing SAP applications on FAST-enabled EMC unified storage. It also
More informationBest Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3. Huawei Enterprise BG, IT Storage Solution Dept Version 1.
Best Practices of Huawei SAP HANA TDI Solution Using OceanStor Dorado V3 Huawei Enterprise BG, IT Storage Solution Dept 2017-7-31 Version 1.0 Contents 1 About This Document... 3 1.1 Overview... 3 1.2 Purpose...
More informationSymantec Protection Center Getting Started Guide. Version 2.0
Symantec Protection Center Getting Started Guide Version 2.0 Symantec Protection Center Getting Started Guide The software described in this book is furnished under a license agreement and may be used
More informationHA100 SAP HANA Introduction
HA100 SAP HANA Introduction. COURSE OUTLINE Course Version: 15 Course Duration: SAP Copyrights and Trademarks 2018 SAP SE or an SAP affiliate company. All rights reserved. No part of this publication may
More informationEMC Solutions for Microsoft Exchange 2007 NS Series iscsi
EMC Solutions for Microsoft Exchange 2007 NS Series iscsi Applied Technology Abstract This white paper presents the latest storage configuration guidelines for Microsoft Exchange 2007 on the Celerra NS
More informationSymantec NetBackup PureDisk Compatibility Matrix Created August 26, 2010
Symantec NetBackup PureDisk 6.6.1 Compatibility Matrix Created August 26, 2010 Copyright 2010 Symantec Corporation. All rights reserved. Symantec, the Symantec Logo, and Backup Exec are trademarks or registered
More informationEMC Backup and Recovery for Microsoft Exchange 2007
EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.
More informationEMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager
EMC Virtual Infrastructure for Microsoft Exchange 2010 Enabled by EMC Symmetrix VMAX, VMware vsphere 4, and Replication Manager Reference Architecture Copyright 2010 EMC Corporation. All rights reserved.
More informationLIFECYCLE MANAGEMENT FOR ORACLE RAC 12c WITH EMC RECOVERPOINT
WHITE PAPER LIFECYCLE MANAGEMENT FOR ORACLE RAC 12c WITH EMC RECOVERPOINT Continuous protection for Oracle environments Simple, efficient patch management and failure recovery Minimal downtime for Oracle
More informationEMC XTREMCACHE ACCELERATES MICROSOFT SQL SERVER
White Paper EMC XTREMCACHE ACCELERATES MICROSOFT SQL SERVER EMC XtremSF, EMC XtremCache, EMC VNX, Microsoft SQL Server 2008 XtremCache dramatically improves SQL performance VNX protects data EMC Solutions
More informationBest Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager. Huawei Enterprise BG, IT Storage Solution Dept Version 1.
Best Practices of Huawei SAP HANA TDI Active-Passive DR Solution Using BCManager Huawei Enterprise BG, IT Storage Solution Dept 2017-8-20 Version 1.0 Contents 1 About This Document... 3 1.1 Overview...
More informationMicrosoft Office SharePoint Server 2007
Microsoft Office SharePoint Server 2007 Enabled by EMC Celerra Unified Storage and Microsoft Hyper-V Reference Architecture Copyright 2010 EMC Corporation. All rights reserved. Published May, 2010 EMC
More informationWharfedale Technologies Inc. Whitepaper January SAP HANA on Public Cloud (Azure)... 3
Table of Contents SAP HANA on Public Cloud (Azure)... 3 Overview...3 Why Public Cloud for HANA...3 SAP HANA Products Certified for Use on Azure...4 Deployment Options...5 HANA on Azure VMs... 5 HANA on
More informationDell EMC SC Series Storage with SAS Front-end Support for VMware vsphere
Dell EMC SC Series Storage with SAS Front-end Support for VMware vsphere Abstract This document describes how to configure VMware vsphere hosts equipped with supported SAS HBAs to access SAN storage on
More informationEMC Solutions for Backup to Disk EMC Celerra LAN Backup to Disk with IBM Tivoli Storage Manager Best Practices Planning
EMC Solutions for Backup to Disk EMC Celerra LAN Backup to Disk with IBM Tivoli Storage Manager Best Practices Planning Abstract This white paper describes how to configure the Celerra IP storage system
More information