1 IBM Tivoli Storage Productivity Center Version Authors: Mike Lamb Patrick Leahy Balwant Rai Jackson Shea

2 Contents Introduction...3 Knowledge and skills prerequisites...3 Important concepts...3 Storage virtualizers...3 Capacity versus capability...3 Tiering...4 Up-tiering and down-tiering...4 MDisk group characteristics...4 General theory of capability calculation...4 Using a SQL query to retrieve back-end configuration data...6 Grouping similarly performing MDisks...6 Complexity of modeling XIV systems with isolated workloads...8 Easy Tier, Storage Optimizer, and storage tier reports...10 Use case: Identifying MDisk groups for up-tiering or down-tiering...10 Description...10 Analyzing storage tier reports...11 Steps for analyzing MDisk groups...12 Steps for analyzing VDisks...13 Case study...16 Analyzing the deletepool2 MDisk group for up-tiering...16 Analyzing the cognos MDisk group for up-tiering...17 Analyzing the mdiskgrp1 MDisk group for down-tiering...19 Analyzing the deletemdiskgrp3 MDisk group for down-tiering...20 Identifying most active VDisks to reduce MDisk group workload...21 Using storage resource groups to analyze application performance...23 Scheduling reports...26 Sending reports by Creating a report view...27 Locating related documentation...29 Appendix 1: SQL query for retrieving back-end data...31 page 2 of 33

3 Introduction The inclusion of storage tier reports in IBM Tivoli Storage Productivity Center Version helps users by providing them with quantitative data to make important decisions about storage tiering. By leveraging estimated capability and actual performance data for IBM System Storage SAN Volume Controller and IBM Storwize V7000, storage tier reports help answer important storage management questions such as: Is a back-end subsystem being utilized to its fullest capability Can a workload be moved to a lower cost pool of storage while still meeting service level agreements How to level out performance in a pool to meet service level agreements The purpose of the white paper is to help users: Define the characteristics of managed disk (MDisk) groups so as to provide an accurate model of the theoretical capability of MDisk groups Use storage tier reports to make storage management decisions Schedule storage tier reports Knowledge and skills prerequisites It is expected that users are: Familiar with back-end storage subsystem architecture and RAID concepts Familiar with the Tivoli Storage Productivity Center GUI and performance reporting Familiar with and know how to execute SQL queries in IBM DB2 using either the command line interface (CLI) or the Control Center (GUI) Important concepts Storage virtualizers In this white paper, the term storage virtualizer is used to refer to SAN Volume Controller and Storwize V7000 storage systems. Capacity versus capability Capability is the term that is used to refer to performance, whereas capacity is the term that is used to refer to space. Storage tier reports help users to engage in capability planning to ensure that existing and future workloads meet or exceed the service level agreements that govern the interaction between storage and applications. Traditionally, users have focused on capacity planning to ensure that they have sufficient space for existing and future applications. page 3 of 33

4 Tiering Tiering is the term that is used to describe storage systems that comprise different performing subsystems, or physical disks within a subsystem that have different price points. The subsystems and physical disks are organized into different MDisk groups in storage virtualizers. Up-tiering and down-tiering Up-tiering and down-tiering are the terms that are used to refer to the process of moving a virtual disk (VDisk) from one type of MDisk group to another MDisk group. Up-tiering refers to a movement from a lower capability pool to a higher capability pool. Usually, this means going from a lower cost pool to a higher cost pool, but that is not always the case. Down-tiering refers to the movement of a workload from a higher capability pool to a lower capability pool. Usually, this means going from a higher cost pool to a lower cost pool, but again, this is not always the case. MDisk group characteristics General theory of capability calculation Storage tier reports produce value as an analytics tool by comparing actual I/O performance metrics with the theoretical capability of a particular MDisk group. To do this, users must provide some of the characteristics of the back-end pool that make up the MDisk group so that the theoretical capability of the MDisk group can be calculated. The characteristics of the back-end pool that are required are: The type of storage system The type of RAID The size and rotation speed of physical disks The number of physical disks The formula that is used in Tivoli Storage Productivity Center to calculate estimated I/O capability assumes a 70/30 read/write workload split and multiplies the number of spindles in an MDisk group by the theoretical capability of each spindle based on the disk technology and rotation speed. RAID type and cache hit ratio values, based on the type of subsystem, is also factored into the I/O per second rate that is used as the theoretical maximum for the MDisk group. (For more information about the read I/O capability formula, see Locating related documentation.) To set the characteristics of a back-end pool using the Tivoli Storage Productivity Center, GUI, expand Disk Manager and Storage Subsystems, select a SAN Volume Controller or Storwize V7000 storage subsystem, and click the MDisk Groups button. (See Illustration 1.) page 4 of 33

5 Illustration 1: Selecting a storage subsystem A list of MDisk groups for the selected subsystem is displayed. When you select an MDisk group, the details panel for the MDisk group is displayed. The characteristics of the back-end pool are set in the Information About the Backend Subsystem Pool section (see Illustration 2). Illustration 2: MDisk group back-end pool characteristics If you select a Storwize V7000 with internal disks, the back-end pool characteristics are automatically set (see Illustration 3). page 5 of 33

6 Illustration 3: Storwize V7000 with internal disks Selecting values1 from the drop-down lists is straightforward with the exception perhaps of specifying the number of physical disks in the back-end pool. It is not always easy to specify how many physical disks make up the MDisks that are presented to a storage virtualizer. Using a SQL query to retrieve back-end configuration data The code (see Appendix 1: SQL query for retrieving back-end data) can be used to produce a table of all SAN Volume Controller or Storwize V7000 MDisk groups in the Tivoli Storage Productivity Center database where each row displays the RAID level and back-end physical disk count for a single MDisk in an MDisk group (see Illustration 4)2. Note: You must probe back-end storage subsystems in order for the SQL query to provide the results. Spare devices are taken into account only on IBM DS6000 and IBM DS8000 series. Illustration 4: Sample output from a back-end SQL query The following section provides some best practice guidelines about creating MDisks on DS8000 and the IBM XIV Storage System and organizing MDisk groups on a back-end array. Grouping similarly performing MDisks In order to maximize predictability and consistency in performance for extents that are randomly distributed throughout an MDisk group, it is important that all of the MDisks in a 1 The constants for the drop-down items, such as the cache-hit ratio for a subsystem type or the I/Os per second of a specific type of physical disk can be customized using the Tivoli Storage Productivity Center CLI (see Locating related documentation). 2 The table that the query produces lists DS6K or DS8K disk totals in one column, and nonds6k or DS8K disk totals in a separate column. page 6 of 33

7 group have identical performance characteristics3. While this is true as a general rule, it becomes more important in the context of storage tier reports which models the theoretical capability of an MDisk group based on the characteristics of a single type of disk and RAID configuration. To illustrate this, consider a typical DS8000 array and the best practice recommendation for presenting volumes as MDisks to be used on a storage virtualizer (see Illustration 5). Starting with a two frame IBM DS8700 with 300 GB 15,000 rpm drives which are configured with RAID 5 protection, 48 8-disk array sites are created, half of which contain a spare drive (6 + P + S)4 and half which do not (7 + P). Because storage virtualizers distribute extents across the presented volumes, we organize each 8-disk array site into a RAID group or rank, which in turn, is placed in its own extent pool from which a single fixed block volume would be constructed for presentation to the storage virtualizer. Illustration 5: Two-frame DS8700 with volume overlay 3 IBM Easy Tier MDisk groups are an exception to the rule because Easy Tier employs autonomic hot spot relocation between solid state drives (SSDs) and hard disk drives (HDDs) within an MDisk group (see Easy Tier, Storage Optimizer, and storage tier reports) Parity + Spare versus 7 + Parity are RAID descriptions of how 8-disk RAID sets are designated. page 7 of 33

8 In this scenario, GB volumes and GB volumes are created. On storage virtualizers, it is best practice to group the 1844 GB into one or more MDisk groups and the GB into one or more MDisk groups depending on whether application isolation requires subdivision of your storage resources. We isolate the 6 + P + S volumes from the 7 + P volumes because they possess slightly different performance characteristics, with the 7 + P volumes having access to a slightly higher physical disk count. If no application isolation is required, then the simplest scenario would be two MDisk groups, one for the 6 +P + S (1582 GB) volumes and one for the 7 + P (1844 GB) volumes. We will refer to the 7 + P MDisk group as the Long group and the 6 + P + S as the Short group. The Long group would contain 24 x 8 or 192 physical disks and the Short group would contain 24 x 7 or 168 physical disks. Complexity of modeling XIV systems with isolated workloads As mentioned in the previous section describing a simple configuration, workload isolation may lead to the creation of multiple MDisk groups. Furthermore, the recommended way to isolate workloads is to first subdivide the MDisks into functional groups, such as those that are 6 + P + S versus those that are 7 + P on different ranks, on the back-end subsystem and then group them into MDisk groups on the storage virtualizer. In our example, we had Long volumes and Short volumes, each of which were localized to pools drawn from a particular 8-Disk Array Site and Rank. The highly virtualized and autonomically optimized architecture of XIV systems complicates this physical isolation. In a simple scenario, (see Illustration 5), an entire XIV system is provisioned into 45 (1 TB disks) 1520 GB5 volumes which are all provisioned to the storage virtualizer and put in a single MDisk group. The MDisk group has 180 physical disks in a fully configured XIV system frame. Each MDisk group contains 15 out of the 45 MDisks, or one third of the 180 physical disks. Hence, we would specify that each MDisk group has 60 physical disks. 5 The XIV system uses decimal capacity specification whereas storage virtualizers use binary capacity specification, so a 1632 decimal GB volume on the XIV system will end up being a 1520 binary GB volume on a storage virtualizer. Using 1 TB physical disks, a fully configured XIV system produces 45 x 1520 GB storage virtualizer, double that for 2 TB physical disks. page 8 of 33

9 MDISK GROUP: XIV1_0 MDISK:XIV1_LV35... SVC MDISK:XIV1_LV02 MDISK:XIV1_LV01 MDISK:XIV1_LV00 LV GB... LV GB XIV1 1TB 7500rpm Illustration 6: Single MDisk group per subsystem However, if workload or departmental isolation leads a storage administrator to subdivide the XIV system capacity into multiple MDisk groups on a storage virtualizer, then that greatly complicates how we model the performance of that MDisk group. Each MDisk has access to all 180 physical disks. As long as all of the MDisks are in the same MDisk group, there is no issue. If we put MDisks from the same XIV system into different MDisk groups, and if we specify 180 physical disks for each of those MDisk groups, then we end up over representing the I/O capability of our environment. The simple solution to this is to arbitrarily prorate or scale the capability in accordance with the capacity of the MDisk group. While this may lead to more threshold breaches where actual measured I/Os per second exceed the theoretical capability, this conservative approach will guard against overestimating the amount of capability in an MDisk group, and more importantly, in the overall environment. For example, suppose a single XIV system fully configured with 1 TB physical disks is broken into three equal MDisk groups with the following names: Finance Marketing Customer_Service6 Each MDisk group contains 15 x 1520 GB MDisks, or one third of the 180 physical disks, so we would specify that each MDisk group has 60 physical disks. 6 MDisk group names cannot contain blank spaces page 9 of 33

10 Easy Tier, Storage Optimizer, and storage tier reports IBM Easy Tier is an autonomic capability in a storage virtualizer that relocates highly utilized extents within an MDisk group to MDisks defined as being in a higher performing tier within that MDisk group, and relocates it to the lower performing tier once the extents become less utilized. The Easy Tier functionality in storage virtualizers deals with two tiers: SSDs and HDDs. Relocation occurs automatically and is not configurable. Storage Optimizer is an analytics and prescriptive function within Tivoli Storage Productivity Center introduced in version 4.1 that produces a heat map of MDisk groups by comparing actual I/O measurements against Disk Magic for IBM7 data based estimations for the particular IBM back-end subsystem. The heat map produced displays color-coded levels of utilization at the MDisk group level. Furthermore, you can specify source and target MDisk groups and request Storage Optimizer to propose VDisk migrations that would level out the performance, and present you with modeled results. While this is similar to storage tier report functionality, there are some key differences. Storage tier reports is also an analytics tool that compares actual I/O rates with theoretical capability. It differentiates itself from Storage Optimizer by providing the following key functionality: User configurable parameters for customized modeling Modeling for non-ibm subsystems Additional detailed performance information to inform tiering decisions Use case: Identifying MDisk groups for uptiering or down-tiering Description The use case describes how users analyze the storage workloads of MDisk groups to determine whether they can be migrated to other MDisk groups in a storage virtualizer. It also shows users how to identify a target MDisk group based on current utilization values that is capable of hosting the workload and performing the actual migration. 7 Disk Magic for IBM is a storage subsystem modeling tool licensed by IBM and customized for use with IBM storage. For more information, see page 10 of 33

11 Analyzing storage tier reports Illustration 7: Use case workflow The starting point of the analysis procedure is the MDisk Groups - Workload Activity Report which provides charts for the most active (and least active) MDisk groups. The specific metrics for capacity and capability are then evaluated to determine whether further investigation is required. If this is the case, then response times are investigated. If it is determined that an MDisk group requires re-balancing, then the VDisk report for the MDisk group is opened. (To open the VDisk report for an MDisk group, click the bar in the chart that represents the VDisk or click the name of the MDisk group in the report.) In the VDisk report, VDisk candidates for relocation are identified (see Illustration 7 above). page 11 of 33

12 Steps for analyzing MDisk groups 1. Use the most active or least active MDisk group chart to select an MDisk group that may require up-tiering or down-tiering. 2. Analyze the values in the following columns in the MDisk group workload report to determine whether up-tiering or down-tiering is required: Step Step 1 Step 2 Column Name Description Comment MDisk Group Read I/O Rate Capability The read I/O capability rate of the MDisk group in operations per second. The read I/O capability rate is at the core of storage tier reports. It is the theoretical capability of an MDisk group against which the actual report data is compared. MDisk Group Max Read I/O Rate The maximum read I/O rate of the MDisk group in operations per second. MDisk Group Read I/O Rate Availability The difference between the read I/O capability rate and the maximum read I/O rate in operations per second. MDisk group workload is considered to be least active when consumed capacity is high and capability is under utilized. MDisk Group Capacity Status If the storage capacity that is allocated is less than the actual storage capacity, a status value of OK is displayed. If the storage capacity that is allocated is more than the actual storage capacity, a status value of Warning is displayed. The actual capacity of the MDisk group is calculated as follows: MDisk group workload is considered to be most active when capacity is highly available and capability is highly utilized. MDisk group workload is considered to be most active when available capacity is high, and capability is highly utilized. MDisk group workload is considered to be least active when when the rate of consumed capacity is high and capability is under utilized. MDisk Group Real Capacity (GB) MDisk Group Capacity 100) MDisk Group Capacity The total storage capacity in GB of all of the disks in the MDisk group. MDisk Group Real The total amount in GB of real page 12 of 33

13 Step Step 3 Column Name Description Comment Capacity storage capacity in the MDisk group. MDisk Group Free Space The total amount of remaining capacity in GB that can be allocated to increase the size of an existing VDisk, or allocated to an additional VDisk. MDisk Group Max Read Response Time The maximum read response time in milliseconds per operation. MDisk group workload is considered to be most active when the maximum read response time is high. MDisk Group Max8 Read The number of hours and Response Time minutes that the maximum Threshold read response time threshold is exceeded over a 24 hour period. MDisk group workload is considered to be most active when the number of hours and minutes that exceed the threshold is high. MDisk Group9 Average Read Response Time The average read response time in milliseconds per operation. MDisk group workload is considered to be most active when the average read response time is high. MDisk Group Max Write Response Time The maximum write response time in milliseconds per operation. MDisk group workload is considered to be most active when the maximum response time is high. MDisk Group Max Write Response Time Threshold The number of hours and minutes that the maximum write response time threshold is exceeded over a 24 hour period. MDisk group workload is considered to be most active when the number of hours and minutes that exceed the threshold is high. Steps for analyzing VDisks The procedure that is used to make decisions whether to migrate VDisks is as follows: 8 The Read Response Time Threshold is set to 100% in the sample reports. This was done for testing purposes. The default value is 70%. 9 You will notice that the Write Response Time threshold is set to 1% in the sample reports. This was customized for testing. The default value is 70%. page 13 of 33

14 1. Use the most active or least active VDisk chart to select a VDisk. 2. Analyze the values in the following columns in the VDisk report to determine whether a VDisk should be migrated: Steps Column Name Description Comment Step 1 VDisk Peak Utilization The highest value of VDisk utilization over a 24-hour period. VDisk workload is considered to be most active when the peak utilization is high. Step 2 VDisk Max Read I/O Rate The maximum read I/O rate of the VDisk in operations per second. VDisk I/O Rate Share of Total VDisk Read I/O The maximum read I/O rate of the VDisk as a percentage of the total VDisk workload is considered to be most active when the maximum read I/O rate is high. VDisk Max Read Response Time The maximum read response time in milliseconds per operation. Step 3 VDisk Max Read Response Time Threshold VDisk Max Write Response Time VDisk Max Write Response Time Threshold VDisk workload is considered to be most active when the rate of maximum read I/O rate of I/O share of total VDisk all the VDisks in the read I/O is high and the MDisk group. capacity share of total VDisk capacity is low. VDisk workload is considered to be most active when the maximum read response time and the number of hours and The number of hours and minutes that the minutes that the maximum read maximum read response response time threshold time threshold for the is exceeded are high. VDisk is exceeded over a 24 hour period. VDisk workload is considered to be most active when the The maximum write maximum write response time in response time and the milliseconds per number of hours and operation. minutes that the maximum write The number of hours and response time threshold is exceeded are high. minutes that the maximum write response page 14 of 33

15 Steps Column Name Description Comment time threshold for the VDisk is exceeded over a 24 hour period. Step 4 VDisk Max Read Cache Hits VDisk Max Read Cache Hits Time Threshold The maximum read cache hits in percent. VDisk workload is considered to be most active when the maximum read cache The number of hours and hits and the number of minutes that the hours and minutes that maximum read cache hits the maximum read time threshold is cache hits time exceeded over a 24 hour threshold is exceeded period. are high. page 15 of 33

16 Case study Analyzing the deletepool2 MDisk group for up-tiering You use the most active MDisk groups chart to identify MDisk groups that may require up-tiering. In this use case, the MDisk group deletepool2 is analyzed further to determine whether it is a suitable candidate for up-tiering. page 16 of 33

17 Step Parameters used to determine tiering Observation Up-tiering recommended 1 MDisk Group Read I/O Rate Capability, MDisk Group Max Read I/O Rate, and MDisk Group Read I/O Rate Availability The maximum read I/O rate is high compared with capability, and read I/O rate availability is negative. Yes 2 MDisk Group Capacity Status, MDisk Group Capacity, MDisk Group Real Capacity, and MDisk Group Free Space The capacity status is OK. In fact, very little capacity is being consumed. Capability, on the other hand, is extremely overutilized (the actual I/O rate maximum is over 25 times that of the theoretical capability). Yes 3 MDisk Group Max Read Response Time, MDisk Group Max Read Response Time Threshold, MDisk Group Average Read Response Time, MDisk Group Max Write Response Time, and MDisk Group Max Write Response Time Threshold Maximum and average read response times are high. Yes Final recommendation Maximum and average write response times are high. The number of hours that the write response time exceeds the threshold is too high. MDisk Group deletepool2 is over-utilized and some of the workloads in this MDisk Group are strongly recommended for up-tiering. Analyzing the cognos MDisk group for up-tiering page 17 of 33

18 Step Parameters used to determine tiering Observation 1 MDisk Group Read I/O Rate Capability, MDisk Group Max Read I/O Rate, MDisk Group Read I/O Rate Availability 2 MDisk Group Capacity Status, MDisk The capacity status is set to No Group Capacity, MDisk Group Real Warning. Capacity, MDisk Group Free Space Consumed capacity is high (79.90 GB), and capability utilization is low fluctuating between 10% and 20%. 3 MDisk Group Max Read Response Time, MDisk Group Max Read Response Time Threshold, MDisk Group Average Read Response Time, MDisk Group Max Write Response Time, and MDisk Group Max Write Response Time Threshold Final Recommendation: The maximum read I/O rate varies from less than 10% in one instance, to 20% in another instance. So, the availability rate of the MDisk group fluctuates between 80% to 90%. Up-tiering recommended Maximum and average read response times are high. No No Maximum and average write response times are high, and the number of hours that the write response exceeds the threshold is too high. MDisk Group cognos is not over-utilized and its workloads are not recommended for up-tiering. page 18 of 33

19 Analyzing the mdiskgrp1 MDisk group for down-tiering Step Parameters used to determine tiering Observation 1 MDisk Group Read I/O Rate Capability, MDisk Group Max Read I/O Rate, MDisk Group Read I/O Rate Availability 2 MDisk Group Capacity Status, MDisk The capacity status is set to Group Capacity, MDisk Group Real Warning. Capacity utilization is Capacity, MDisk Group Free Space also high. Yes 3 MDisk Group Max Read Response Time, MDisk Group Max Read Response Time Threshold, MDisk Group Average Read Response Time, MDisk Group Max Write Response Time, MDisk Group Max Write Response Time Threshold Yes Final Recommendation: The availability rate is very high. Down-tiering recommended Maximum and average read response times are very low. Yes Maximum and average write response times are OK and the number of hours that the write response exceeds the threshold is too high. MDisk Group mdiskgrp1 is under-utilized and its workloads are strongly recommended for downtiering. page 19 of 33

20 Analyzing the deletemdiskgrp3 MDisk group for down-tiering Step Parameters used to determine tiering Observation 1 MDisk Group Read I/O Rate Capability, MDisk Group Max Read I/O Rate, MDisk Group Read I/O Rate Availability 2 MDisk Group Capacity Status, MDisk The capacity status is set to OK, Group Capacity, MDisk Group Real but there is little free space. Capacity, MDisk Group Free Space Yes 3 MDisk Group Max Read Response Time, MDisk Group Max Read Response Time Threshold, MDisk Group Average Read Response Time, MDisk Group Max Write Response Time, MDisk Group Max Write Response Time Threshold Yes Final Recommendation: Availability is high. Down-tiering recommended Response times are reasonable. Yes MDisk Group deletemdiskgrp3 is under utilized and its workloads are recommended for down-tiering. page 20 of 33

21 Identifying most active VDisks to reduce MDisk group workload Analyzing the tvt VDisk The most active VDisk in the MDisk group is tvt. Complete the steps in the following table to determine whether the VDisk requires up-tiering or down-tiering. Step Parameters used to determine tiering Observation Up-tiering recommended 1 VDisk Peak Utilization VDisk peak utilization is high. Yes 2 VDisk Max Read I/O Rate, VDisk I/O Rate Share of Total VDisk Max Read I/O Rate is very high. VDisk I/O Rate Yes page 21 of 33

22 Step Parameters used to determine tiering Observation Up-tiering recommended VDisk Read I/O share of Total Vdisk read I/O Rate is high and VDisk capacity share of total VDisk Capacity is low. 3 VDisk Max Read Response Time, VDisk Max Read Response Time Threshold, VDisk Max Write Response Time, and VDisk Max Write Response Time Threshold Read and write response Yes times are high and the number of hours that the read and write response time thresholds are exceeded are high. 4 VDisk Max Read Cache Hits and The maximum read cache Yes VDisk Max Read Cache Hits hits and the number of hours Time Threshold that the maximum read cache hit threshold is exceeded is high. Final Recommendation Migrating the VDisk tvt to another MDisk group with adequate capacity would reduce the MDisk group utilization. It will cool off the Mdisk group. Analyzing the tpcblade4_10 VDisk The second most active VDisk in the MDisk group is tpcblade4_10. Complete the steps in the following table to determine whether the VDisk requires up-tiering or down-tiering. page 22 of 33

23 Step 1 2 Parameters used to determine tiering VDisk Peak Utilization Observation VDisk peak utilization is low. Up-tiering recommended Yes VDisk maximum read read VDisk Max Read I/O Rate, VDisk I/O Yes I/O rate is low. VDisk I/O Rate Share of Total VDisk Read I/O rate share of the total VDisk read I/O rate is high as is the VDisk capacity share of total VDisk capacity. 3 VDisk Max Read Response Time, VDisk Max Read Response Time Threshold, VDisk Max Write Response Time, VDisk Max Write Response Time Threshold Maximum read and write No response times are low as is the number of hours that the maximum read and write response time thresholds are exceeded. 4 VDisk Max Read Cache Hits and VDisk Max Read Cache Hits Time Threshold The maximum read cache hits is high as is the number of hours that the maximum read cache hits threshold is exceeded. Final Recommendation: No Migrating VDisk tpcblade4_10 will not cool off the MDisk group. Migration is not recommended. Using storage resource groups to analyze application performance In IBM Tivoli Storage Productivity Center Version 4.2.2, storage resource group functionality has been extended to include reporting. In addition to grouping objects in topology view, storage resource groups can also be used to aggregate objects to provide views into performance data that transcends the boundaries that are imposed by virtualizer software. When VDisk Workload Activity Reports is selected, the user is presented with three options. They can run a report that shows VDisks in MDisk groups, VDisks in a storage virtualizer, or VDisks in storage resource groups (see Illustration 8). page 23 of 33

24 Illustration 8: Selecting a Storage Resource Group - VDisk Workload Activity Report To run a storage resource group report: 1. In the VDisk Workload Activity Reports window, select Storage Resource Group VDisk Workload Activity Report. 2. Click Next. 3. Select a storage virtualizer, 4. Enter a date range or select a date filter. 5. Click Finish. The report compares VDisk peak utilization percentages for all of the VDisks in all of the storage resource groups in the storage virtualizer. Two charts are displayed at the top of the report which rank the most active and least active storage resource groups based on average VDisk utilization (see Illustration 9). The report can also be used to determine how well storage is performing against service level agreements. Furthermore, it is possible to view the aggregated average I/O rate or response time for all of the VDisks associated with a particular application by assigning the VDisks to a storage resource group before you run the report. page 24 of 33

25 Illustration 9: Comparing storage resource groups in a storage virtualizer Note: The report has been modified to present the summary lines for the two storage resource groups closer together. page 25 of 33

26 Step Parameters used to determine SLA compliance 1 VDisk Peak Utilization Observation The SVC8vol storage resource group averaged I/Os per second with an average of the daily maximum values coming in at for read I/O rate. The writes averaged 4.5 I/O per second. 2 Read and Write Response Times The SVC8vol storage resource group has an average read response time of 0.35 milliseconds per operation with a maximum of 0.45 milliseconds per operation. Write response time average and maximum write response time are 1.28 milliseconds per operation and 3.6 milliseconds per operation, respectively. Evaluation This is very low utilization. Confirming with owner of the application whether this is the expected amount of I/O for the application. Very low response times. Storage environment is optimally configured. Scheduling reports You can schedule tiering reports can to run automatically every day, every week, every month, and every year. Note: Tiering reports use the Tivoli Storage Productivity Center's Performance Monitor to collect daily aggregated data so the data is only current as of the last day. When you schedule reports you can set parameters to monitor specific resources to identify issues in MDisk groups, VDisks, or storage resource groups. Furthermore, you can configure reports to run interactively so that you can specify parameters, such as the name of the storage virtualizer, when you run the report. Instead of specifying start and end dates for a report, you can use relative date ranges so that your schedule definitions remain relevant. For example, use the last 7 days as the date range instead of specifying a specific 7-day time period. A variety of output formats are available such as: HTML page 26 of 33

27 PDF XML Microsoft Excel The output of a report can be saved to the Content Store and then viewed in Tivoli Common Reporting or sent by to specified recipients. You can configure Tivoli Common Reporting to show the most recent report output when the report is run by default. Sending reports by You must configure settings to work with Tivoli Common Reporting. This involves setting up the mail server to reports. 1. On Windows OS, click Start -> All Programs -> Tivoli Common Reporting > IBM Cognos Configuration.) 2. In the Explorer panel, expand Data Access and click Notification. In the Notification - Component Properties panel, make the following changes: i. Set the value for SMTP mail server. ii. Edit the account and password information. iii. Save your changes. 3. Click the Restart button to restart IBM Cognos. Creating a report view You can create a report view, which uses the same report specification as the source report, but has different properties such as prompt values, schedules, run options, languages, and output formats. Let's create a report view with the following settings: The report runs every week The report provides output for the last 7 days The report generates a PDF file in landscape format The report output language is French 1. To create the report view, click the Report View icon. 2. (Optional) Rename report view. 3. (Optional) Choose a folder to store the report. 4. Click Finish. 5. Click the icon to open the Report View schedule. page 27 of 33

28 6. Set the properties for the report. i Select French as the language for the report. Open the Report View tabbed page. i. Default Action: Run the Report ii. Override the default values. iii. Configure the PDF settings. iv. Set the orientation of the PDF file output to Landscape. v. Configure the prompt values. i. Select Storage Virtualizer. ii. Choose Last 7 days as the date range. Click OK. Open the report view schedule again. i. Select Monday. page 28 of 33

29 ii. Click OK. Locating related documentation To learn more about storage tier reports: 1. Click this link: Tivoli Storage Productivity Center Information Center. 2. Click IBM Tivoli Storage Productivity Center Version Expand the Reporting node. 4. Expand Storage tier reports. 5. Expand Using Tivoli Common Reporting to run storage tier reports. 6. See the topics bout the reports, and the topic about the read I/O capability formula. To learn more about setting MDisk group back-end pool characteristics using the CLI: 1. Click this link: Tivoli Storage Productivity Center Information Center. 2. Click IBM Tivoli Storage Productivity Center Version Expand the Reference node. 4. Expand the Commands node. 5. Expand the tpctool command node. 6. See the following topics: Topic Short description setarray The setarray command is used to set the type of back-end storage system, type of Redundant Array of Independent Disks (RAID), type of disk, and number of disks for an array. autosetarray The autosetarray command is used to extract and save information about storage pools. You can save information about a storage pool such as the type of back-end storage system, type of RAID, and type of disk. To do this you use a default pattern or create a pattern that matches the names of pools in a subsystem. If the match is successful, the information about the pool is extracted and saved. setbackendtype The setbackendtype command is used to set or update the type of back-end storage system. page 29 of 33

30 Topic Short description setbackenddisktype The setbackenddisktype command is used to set or update the type of back-end disk. setbackendraidtype The setbackendraidtype command is used to set the type of back-end RAID arrays. page 30 of 33

31 Appendix 1: SQL query for retrieving back-end data select distinct virtualizer.display_name as virtualizer, mdisk_group.display_name as mdisk_group, ss.type as backend_ss, ss_pool.display_name as backend_pool, ss_pool.raid_level as pool_raid_level, (select count(*) from tpcreport.storageextent se, tpcreport.diskdrive2storageextent dd2se where se.storage_extent_id = dd2se.storage_extent_id and se.pool_id = ss_pool.pool_id ) as pool_num_disks,(select count(*) from tpcreport.storagesubsystem_rank r, tpcreport.storagesubsystem_arraysite arr, tpcreport.diskdrive dd where r.pool_id = ss_pool.pool_id and r.storage_extent_id = arr.storage_extent_id and arr.disk_group_id = dd.disk_group_id and dd.flags!= 'SPARE_DEVICE') as ds6k_8k_pool_num_disks from tpcreport.storagesubsystem virtualizer, tpcreport.storagepool mdisk_group, tpcreport.backenddisk mdisk, tpcreport.storagevolume sv, tpcreport.storagepool ss_pool, tpcreport.storagesubsystem ss where mdisk_group.primordial = 'False' and mdisk_group.subsystem_id = virtualizer.subsystem_id and virtualizer.type in ('SVC','Storwize V7000') and mdisk_group.pool_id = mdisk.pool_id and mdisk.storage_extent_id = sv.backend_disk_id and sv.pool_id = ss_pool.pool_id and ss_pool.subsystem_id = ss.subsystem_id order by virtualizer ; page 31 of 33

32 Copyright IBM Corporation 2011 All Rights Reserved. IBM Systems and Technology Group Route 100 Somers, New York Printed in United States of America Neither this documentation nor any part of it may be copied or reproduced in any form or by any means or translated into another language, without the prior consent of all of the above mentioned copyright owners. IBM makes no warranties or representations with respect to the content hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. IBM assumes no responsibility for any errors that may appear in this document. The information contained in this document is subject to change without any notice. IBM reserves the right to make any such changes without obligation to notify any person of such revision or changes. IBM makes no commitment to keep the information contained herein up to date. page 32 of 33

33 The information in this document concerning non-ibm products was obtained from the supplier(s) of those products. IBM has not tested such products and cannot confirm the accuracy of the performance, compatibility or any other claims related to non-ibm products. Questions about the capabilities of non-ibm products should be addressed to the supplier(s) of those products. IBM, the IBM logo, DB2, DB2 Universal Database, and Tivoli are trademarks or registered trademarks of International Business Machines Corporation in the United States, other countries, or both. Microsoft is a trademark of Microsoft Corporation in the United States, other countries, or both. Other company, product, or service names may be trademarks or service marks of others. References in this publication to IBM products or services do not imply that IBM intends to make them available in all countries in which IBM operates. page 33 of 33

IBM System Storage SAN Volume Controller IBM Easy Tier in release

IBM System Storage SAN Volume Controller IBM Easy Tier in release IBM System Storage SAN Volume Controller IBM Easy Tier in 7.3.0 release Kushal S. Patel, Shrikant V. Karve IBM Systems and Technology Group ISV Enablement July 2014 Copyright IBM Corporation, 2014 Table

More information

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide

Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Implementing IBM Easy Tier with IBM Real-time Compression IBM Redbooks Solution Guide Overview IBM Easy Tier is a performance function that automatically and non-disruptively migrates frequently accessed

More information

IBM System Storage SAN Volume Controller IBM Easy Tier enhancements in release

IBM System Storage SAN Volume Controller IBM Easy Tier enhancements in release IBM System Storage SAN Volume Controller IBM Easy Tier enhancements in 7.5.0 release Kushal S. Patel, Shrikant V. Karve, Sarvesh S. Patel IBM Systems, ISV Enablement July 2015 Copyright IBM Corporation,

More information

IBM InfoSphere Data Replication s Change Data Capture (CDC) for DB2 LUW databases (Version ) Performance Evaluation and Analysis

IBM InfoSphere Data Replication s Change Data Capture (CDC) for DB2 LUW databases (Version ) Performance Evaluation and Analysis Page 1 IBM InfoSphere Data Replication s Change Data Capture (CDC) for DB2 LUW databases (Version 10.2.1) Performance Evaluation and Analysis 2014 Prasa Urithirakodeeswaran Page 2 Contents Introduction...

More information

Lenovo SAN Manager. Rapid Tier and Read Cache. David Vestal, WW Product Marketing. June Lenovo.com/systems

Lenovo SAN Manager. Rapid Tier and Read Cache. David Vestal, WW Product Marketing. June Lenovo.com/systems Lenovo SAN Manager Rapid Tier and Read Cache June 2017 David Vestal, WW Product Marketing Lenovo.com/systems Table of Contents Introduction... 3 Automated Sub-LUN Tiering... 4 LUN-level tiering is inflexible

More information

Planning for Easy Tier with IBM System Storage Storwize V7000 and SAN Volume Controller

Planning for Easy Tier with IBM System Storage Storwize V7000 and SAN Volume Controller Planning for Easy Tier with IBM System Storage Storwize V7000 and SAN Volume Controller May 2013 Nick Clayton Carlos Fuente Document WP102295 Systems and Technology Group 2013, International Business Machines

More information

Lenovo SAN Manager - Provisioning and Mapping Volumes

Lenovo SAN Manager - Provisioning and Mapping Volumes Lenovo SAN Manager - Provisioning and Mapping Volumes Lenovo ThinkSystem DS2200, DS4200, DS6200 June 2017 David Vestal, WW Product Marketing Lenovo.com/systems Table of Contents Introduction... 2 Provisioning

More information

Oracle Flash Storage System QoS Plus Operation and Best Practices ORACLE WHITE PAPER OCTOBER 2016

Oracle Flash Storage System QoS Plus Operation and Best Practices ORACLE WHITE PAPER OCTOBER 2016 Oracle Flash Storage System QoS Plus Operation and Best Practices ORACLE WHITE PAPER OCTOBER 2016 Table of Contents Introduction 1 When to Use Auto-Tiering 1 Access Skews 1 Consistent Access 2 Recommendations

More information

IBM. Systems management Disk management. IBM i 7.1

IBM. Systems management Disk management. IBM i 7.1 IBM IBM i Systems management Disk management 7.1 IBM IBM i Systems management Disk management 7.1 Note Before using this information and the product it supports, read the information in Notices, on page

More information

IBM i Version 7.3. Systems management Disk management IBM

IBM i Version 7.3. Systems management Disk management IBM IBM i Version 7.3 Systems management Disk management IBM IBM i Version 7.3 Systems management Disk management IBM Note Before using this information and the product it supports, read the information in

More information

Vendor: IBM. Exam Code: Exam Name: IBM System Storage DS8000 Technical Solutions V3. Version: Demo

Vendor: IBM. Exam Code: Exam Name: IBM System Storage DS8000 Technical Solutions V3. Version: Demo Vendor: IBM Exam Code: 000-453 Exam Name: IBM System Storage DS8000 Technical Solutions V3 Version: Demo QUESTION NO: 1 Which function is unique to the DS8000 within the following IBM disk storage products:

More information

IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA

IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA IBM System Storage Reference Architecture featuring IBM FlashSystem for SAP landscapes, incl. SAP HANA IBM SAP International Competence Center, IBM Germany Version 1.3, September 2015 isicc@de.ibm.com

More information

PowerVault MD3 SSD Cache Overview

PowerVault MD3 SSD Cache Overview PowerVault MD3 SSD Cache Overview A Dell Technical White Paper Dell Storage Engineering October 2015 A Dell Technical White Paper TECHNICAL INACCURACIES. THE CONTENT IS PROVIDED AS IS, WITHOUT EXPRESS

More information

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510

A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510 A Comparative Study of Microsoft Exchange 2010 on Dell PowerEdge R720xd with Exchange 2007 on Dell PowerEdge R510 Incentives for migrating to Exchange 2010 on Dell PowerEdge R720xd Global Solutions Engineering

More information

Stellar performance for a virtualized world

Stellar performance for a virtualized world IBM Systems and Technology IBM System Storage Stellar performance for a virtualized world IBM storage systems leverage VMware technology 2 Stellar performance for a virtualized world Highlights Leverages

More information

Here is Your Customized Document

Here is Your Customized Document Here is Your Customized Document Your Configuration is: Manage LUNs Model - VNX5300 Storage Type - VNX for Block (SAN) Connection Type - Fibre Channel Switch or Boot from SAN Operating System - ESX Server

More information

Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs

Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs Lenovo SAN Manager Rapid RAID Rebuilds and Performance Volume LUNs Lenovo ThinkSystem DS2200, DS4200, DS6200 June 2017 David Vestal, WW Product Marketing Lenovo.com/systems Table of Contents Introduction...

More information

EMC Unity Family. Monitoring System Performance. Version 4.2 H14978 REV 03

EMC Unity Family. Monitoring System Performance. Version 4.2 H14978 REV 03 EMC Unity Family Version 4.2 Monitoring System Performance H14978 REV 03 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published July 2017 Dell believes the information in this

More information

DS8880 High Performance Flash Enclosure Gen2

DS8880 High Performance Flash Enclosure Gen2 Front cover DS8880 High Performance Flash Enclosure Gen2 Michael Stenson Redpaper DS8880 High Performance Flash Enclosure Gen2 The DS8880 High Performance Flash Enclosure (HPFE) Gen2 is a 2U Redundant

More information

Using the Storage Tier Advisor Tool (STAT) and Easy Tier TM on the IBM Storwize V7000

Using the Storage Tier Advisor Tool (STAT) and Easy Tier TM on the IBM Storwize V7000 Using the Storage Tier Advisor Tool (STAT) and Easy Tier TM on the IBM Storwize V7000 Gonzalo Fuentes Dan Riedel William Wiegand IBM System and Technology Group / IBM Advanced Technical Skills February

More information

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary

InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary InfoSphere Warehouse with Power Systems and EMC CLARiiON Storage: Reference Architecture Summary v1.0 January 8, 2010 Introduction This guide describes the highlights of a data warehouse reference architecture

More information

DS8880 High-Performance Flash Enclosure Gen2

DS8880 High-Performance Flash Enclosure Gen2 DS8880 High-Performance Flash Enclosure Gen2 Bert Dufrasne Kerstin Blum Jeff Cook Peter Kimmel Product Guide DS8880 High-Performance Flash Enclosure Gen2 This IBM Redpaper publication describes the High-Performance

More information

SysGauge SYSTEM MONITOR. User Manual. Version 4.7. Apr Flexense Ltd.

SysGauge SYSTEM MONITOR. User Manual. Version 4.7. Apr Flexense Ltd. SysGauge SYSTEM MONITOR User Manual Version 4.7 Apr 2018 www.sysgauge.com info@flexense.com 1 1 SysGauge Product Overview...3 2 SysGauge Product Versions...6 3 Product Installation...7 4 System Monitor

More information

IBM i Virtual I/O Performance in an IBM System Storage SAN Volume Controller with IBM System Storage DS8000 Environment

IBM i Virtual I/O Performance in an IBM System Storage SAN Volume Controller with IBM System Storage DS8000 Environment IBM i Virtual I/O Performance in an IBM System Storage SAN Volume Controller with IBM System Storage DS8000 Environment This document can be found in the IBM Techdocs library, www.ibm.com/support/techdocs

More information

IBM XIV Storage System

IBM XIV Storage System IBM XIV Storage System Technical Description IBM XIV Storage System Storage Reinvented Performance The IBM XIV Storage System offers a new level of high-end disk system performance and reliability. It

More information

An Oracle White Paper September Oracle Utilities Meter Data Management Demonstrates Extreme Performance on Oracle Exadata/Exalogic

An Oracle White Paper September Oracle Utilities Meter Data Management Demonstrates Extreme Performance on Oracle Exadata/Exalogic An Oracle White Paper September 2011 Oracle Utilities Meter Data Management 2.0.1 Demonstrates Extreme Performance on Oracle Exadata/Exalogic Introduction New utilities technologies are bringing with them

More information

IBM Storwize V7000: For your VMware virtual infrastructure

IBM Storwize V7000: For your VMware virtual infrastructure IBM Storwize V7000: For your VMware virtual infrastructure Innovative midrange disk system leverages integrated storage technologies Highlights Complement server virtualization, extending cost savings

More information

Executive Brief June 2014

Executive Brief June 2014 (707) 595-3607 Executive Brief June 2014 Comparing IBM Power Systems to Cost/Benefit Case for Transactional Applications Introduction Demand for transaction processing solutions continues to grow. Although

More information

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo

Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo Front cover Using Read Intensive SSDs with Lenovo Storage V Series and IBM Storwize for Lenovo Introduces Read Intensive SSD Identification on Lenovo Storage V-series product family Highlights the tips

More information

SharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Enterprise Intranet Collaboration Environment

SharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Enterprise Intranet Collaboration Environment SharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Enterprise Intranet Collaboration Environment This document is provided as-is. Information and views expressed in this document, including

More information

IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://

IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps:// IT Certification Exams Provider! Weofferfreeupdateserviceforoneyear! h ps://www.certqueen.com Exam : 000-208 Title : Open Systems Storage Solutions Version 6 Version : DEMO 1 / 6 1. A customer reports

More information

Veritas NetBackup OpsCenter Reporting Guide. Release 8.0

Veritas NetBackup OpsCenter Reporting Guide. Release 8.0 Veritas NetBackup OpsCenter Reporting Guide Release 8.0 Veritas NetBackup OpsCenter Reporting Guide Legal Notice Copyright 2016 Veritas Technologies LLC. All rights reserved. Veritas and the Veritas Logo

More information

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System

Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Microsoft Exchange Server 2010 workload optimization on the new IBM PureFlex System Best practices Roland Mueller IBM Systems and Technology Group ISV Enablement April 2012 Copyright IBM Corporation, 2012

More information

Solid State Drive (SSD) Cache:

Solid State Drive (SSD) Cache: Solid State Drive (SSD) Cache: Enhancing Storage System Performance Application Notes Version: 1.2 Abstract: This application note introduces Storageflex HA3969 s Solid State Drive (SSD) Cache technology

More information

EMC XTREMCACHE ACCELERATES ORACLE

EMC XTREMCACHE ACCELERATES ORACLE White Paper EMC XTREMCACHE ACCELERATES ORACLE EMC XtremSF, EMC XtremCache, EMC VNX, EMC FAST Suite, Oracle Database 11g XtremCache extends flash to the server FAST Suite automates storage placement in

More information

Technical Note P/N REV A01 March 29, 2007

Technical Note P/N REV A01 March 29, 2007 EMC Symmetrix DMX-3 Best Practices Technical Note P/N 300-004-800 REV A01 March 29, 2007 This technical note contains information on these topics: Executive summary... 2 Introduction... 2 Tiered storage...

More information

IBM System Storage DS5020 Express

IBM System Storage DS5020 Express IBM DS5020 Express Manage growth, complexity, and risk with scalable, high-performance storage Highlights Mixed host interfaces support (FC/iSCSI) enables SAN tiering Balanced performance well-suited for

More information

SharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Social Environment

SharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Social Environment SharePoint 2010 Technical Case Study: Microsoft SharePoint Server 2010 Social Environment This document is provided as-is. Information and views expressed in this document, including URL and other Internet

More information

IBM Storwize V5000 disk system

IBM Storwize V5000 disk system IBM Storwize V5000 disk system Latest addition to IBM Storwize family delivers outstanding benefits with greater flexibility Highlights Simplify management with industryleading graphical user interface

More information

Exam : Title : High-End Disk Solutions for Open Systems Version 1. Version : DEMO

Exam : Title : High-End Disk Solutions for Open Systems Version 1. Version : DEMO Exam : 000-206 Title : High-End Disk Solutions for Open Systems Version 1 Version : DEMO 1. A customer has purchased three IBM System Storage DS8300 systems and would like to have their SAN and storage

More information

EMC Ionix ControlCenter (formerly EMC ControlCenter) 6.0 StorageScope

EMC Ionix ControlCenter (formerly EMC ControlCenter) 6.0 StorageScope EMC Ionix ControlCenter (formerly EMC ControlCenter) 6.0 StorageScope Best Practices Planning Abstract This white paper provides advice and information on practices that will enhance the flexibility of

More information

Dell PowerVault DL Backup to Disk Appliance and. Storage Provisioning Option

Dell PowerVault DL Backup to Disk Appliance and. Storage Provisioning Option Dell PowerVault DL Backup to Disk Appliance and the Symantec Backup Exec Storage Provisioning Option The software described in this book is furnished under a license agreement and may be used only in accordance

More information

Copyright...4. Overview Managing Snapshots... 6

Copyright...4. Overview Managing Snapshots... 6 Contents 2 Contents Copyright...4 Overview... 5 Managing Snapshots... 6 Company Snapshots...6 Examples of Sensitive Data Preservation in Snapshots... 9 To Take a Snapshot...10 To Toggle the Visibility

More information

... IBM Power Systems with IBM i single core server tuning guide for JD Edwards EnterpriseOne

... IBM Power Systems with IBM i single core server tuning guide for JD Edwards EnterpriseOne IBM Power Systems with IBM i single core server tuning guide for JD Edwards EnterpriseOne........ Diane Webster IBM Oracle International Competency Center January 2012 Copyright IBM Corporation, 2012.

More information

All-Flash Storage Solution for SAP HANA:

All-Flash Storage Solution for SAP HANA: All-Flash Storage Solution for SAP HANA: Storage Considerations using SanDisk Solid State Devices WHITE PAPER Western Digital Technologies, Inc. 951 SanDisk Drive, Milpitas, CA 95035 www.sandisk.com Table

More information

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays

Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays TECHNICAL REPORT: Performance Study Benefits of Automatic Data Tiering in OLTP Database Environments with Dell EqualLogic Hybrid Arrays ABSTRACT The Dell EqualLogic hybrid arrays PS6010XVS and PS6000XVS

More information

ADDENDUM TO: BENCHMARK TESTING RESULTS UNPARALLELED SCALABILITY OF ITRON ENTERPRISE EDITION ON SQL SERVER

ADDENDUM TO: BENCHMARK TESTING RESULTS UNPARALLELED SCALABILITY OF ITRON ENTERPRISE EDITION ON SQL SERVER ADDENDUM TO: BENCHMARK TESTING RESULTS UNPARALLELED SCALABILITY OF ITRON ENTERPRISE EDITION ON SQL SERVER EMC Information Infrastructure provides the foundation Essentials Itron and Microsoft reached 37,500

More information

IBM EXAM QUESTIONS & ANSWERS

IBM EXAM QUESTIONS & ANSWERS IBM 000-452 EXAM QUESTIONS & ANSWERS Number: 000-452 Passing Score: 800 Time Limit: 120 min File Version: 68.8 http://www.gratisexam.com/ IBM 000-452 EXAM QUESTIONS & ANSWERS Exam Name: IBM Storwize V7000

More information

How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity

How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity 9-November-2010 Singapore How Smarter Systems Deliver Smarter Economics and Optimized Business Continuity Shiva Anand Neiker Storage Sales Leader STG ASEAN How Smarter Systems Deliver Smarter Economics

More information

IBM System Storage DS6800

IBM System Storage DS6800 Enterprise-class storage in a small, scalable package IBM System Storage DS6800 Highlights Designed to deliver Designed to provide over enterprise-class functionality, 1600 MBps performance for with open

More information

Isilon InsightIQ. Version User Guide

Isilon InsightIQ. Version User Guide Isilon InsightIQ Version 4.1.1 User Guide Copyright 2009-2017 Dell Inc. or its subsidiaries. All rights reserved. Published January 2017 Dell believes the information in this publication is accurate as

More information

IBM FlashSystems with IBM i

IBM FlashSystems with IBM i IBM FlashSystems with IBM i Proof of Concept & Performance Testing Fabian Michel Client Technical Architect 1 2012 IBM Corporation Abstract This document summarizes the results of a first Proof of Concept

More information

Using EMC FAST with SAP on EMC Unified Storage

Using EMC FAST with SAP on EMC Unified Storage Using EMC FAST with SAP on EMC Unified Storage Applied Technology Abstract This white paper examines the performance considerations of placing SAP applications on FAST-enabled EMC unified storage. It also

More information

IBM Real-time Compression and ProtecTIER Deduplication

IBM Real-time Compression and ProtecTIER Deduplication Compression and ProtecTIER Deduplication Two technologies that work together to increase storage efficiency Highlights Reduce primary storage capacity requirements with Compression Decrease backup data

More information

Maximize Operational Efficiency in a Tiered Storage Environment

Maximize Operational Efficiency in a Tiered Storage Environment W H I T E P A P E R : T E C H N I C A L Maximize Operational Efficiency in a Tiered Storage Environment Use Cases for Orchestrated Volume and Page-based Migration with Hitachi Tiered Storage Manager (HTSM)

More information

EMC VSPEX END-USER COMPUTING

EMC VSPEX END-USER COMPUTING IMPLEMENTATION GUIDE EMC VSPEX END-USER COMPUTING Citrix XenDesktop 7.1 and VMware vsphere for up to 500 Virtual Desktops Enabled by EMC VNXe3200 and EMC Powered Backup EMC VSPEX Abstract This describes

More information

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide

Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide Using the IBM DS8870 in an OpenStack Cloud Environment IBM Redbooks Solution Guide OpenStack is being developed as an industry standard cloud-computing project. It was started by Rackspace Cloud and NASA

More information

Symantec Protection Center Getting Started Guide. Version 2.0

Symantec Protection Center Getting Started Guide. Version 2.0 Symantec Protection Center Getting Started Guide Version 2.0 Symantec Protection Center Getting Started Guide The software described in this book is furnished under a license agreement and may be used

More information

Jeremy Canady. IBM Systems and Technology Group ISV Enablement March 2013

Jeremy Canady. IBM Systems and Technology Group ISV Enablement March 2013 Introducing the IBM Storage Integration Server An introduction to how the IBM Storage Integration Server provides a new level of simplicity to storage integrations Jeremy Canady IBM Systems and Technology

More information

Exam : Title : High-End Disk for Open Systems V2. Version : DEMO

Exam : Title : High-End Disk for Open Systems V2. Version : DEMO Exam : 000-968 Title : High-End Disk for Open Systems V2 Version : DEMO 1.An international company has a heterogeneous IBM storage environment with two IBM DS8700 systems in a Metro Mirror relationship.

More information

BrightStor ARCserve Backup for Windows

BrightStor ARCserve Backup for Windows BrightStor ARCserve Backup for Windows Volume Shadow Copy Service Guide r11.5 D01191-2E This documentation and related computer software program (hereinafter referred to as the "Documentation") is for

More information

IBM Tivoli Storage Manager for HP-UX Version Installation Guide IBM

IBM Tivoli Storage Manager for HP-UX Version Installation Guide IBM IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM IBM Tivoli Storage Manager for HP-UX Version 7.1.4 Installation Guide IBM Note: Before you use this information and the product

More information

Hitachi Storage Management Pack for VMware vrealize Operations Dashboard User s Guide

Hitachi Storage Management Pack for VMware vrealize Operations Dashboard User s Guide Hitachi Storage Management Pack for VMware vrealize Operations Dashboard User s Guide FASTFIND LINKS Document Organization Software Version Getting Help Contents MK-92ADPTR082-02 All Rights Reserved, Copyright

More information

Symantec NetBackup OpsCenter Reporting Guide. Release 7.7

Symantec NetBackup OpsCenter Reporting Guide. Release 7.7 Symantec NetBackup OpsCenter Reporting Guide Release 7.7 Symantec NetBackup OpsCenter Reporting Guide The software described in this book is furnished under a license agreement and may be used only in

More information

EMC Unisphere for VMAX Database Storage Analyzer

EMC Unisphere for VMAX Database Storage Analyzer EMC Unisphere for VMAX Database Storage Analyzer Version 8.0.3 Online Help (PDF version) Copyright 2014-2015 EMC Corporation. All rights reserved. Published in USA. Published June, 2015 EMC believes the

More information

VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family

VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family VMware Site Recovery Manager 5.x guidelines for the IBM Storwize family A step-by-step guide IBM Systems and Technology Group ISV Enablement February 2014 Copyright IBM Corporation, 2014 Table of contents

More information

HP SAS benchmark performance tests

HP SAS benchmark performance tests HP SAS benchmark performance tests technology brief Abstract... 2 Introduction... 2 Test hardware... 2 HP ProLiant DL585 server... 2 HP ProLiant DL380 G4 and G4 SAS servers... 3 HP Smart Array P600 SAS

More information

IBM Tivoli Monitoring for Databases. Release Notes. Version SC

IBM Tivoli Monitoring for Databases. Release Notes. Version SC IBM Tivoli Monitoring for Databases Release Notes Version 5.1.1 SC23-4851-00 IBM Tivoli Monitoring for Databases Release Notes Version 5.1.1 SC23-4851-00 Note Before using this information and the product

More information

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018 EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance

More information

GLOBAL APPLICATION & SAN ACCELERATION WITH SOLID-STATE STORAGE A WHITE PAPER

GLOBAL APPLICATION & SAN ACCELERATION WITH SOLID-STATE STORAGE A WHITE PAPER GLOBAL APPLICATION & SAN ACCELERATION WITH SOLID-STATE STORAGE A GLOBAL APPLICATION AND SAN ACCELERATION WITH SOLID-STATE STORAGE ABSTRACT Solid-state storage or memory is becoming an increasingly common

More information

Milestone Solution Partner IT Infrastructure Components Certification Report

Milestone Solution Partner IT Infrastructure Components Certification Report Milestone Solution Partner IT Infrastructure Components Certification Report HUAWEI OceanStor 2800 V3 27-08-2015 Table of Contents Executive Summary:... 4 Abstract... 4 Certified Products... 4 Key Findings...

More information

Oracle Event Processing Extreme Performance on Sparc T5

Oracle Event Processing Extreme Performance on Sparc T5 Oracle Event Processing Extreme Performance on Sparc T5 An Oracle Event Processing (OEP) Whitepaper ORACLE WHITE PAPER AUGUST 2014 Table of Contents Introduction 2 OEP Architecture 2 Server Architecture

More information

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE

EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE White Paper EMC XTREMCACHE ACCELERATES VIRTUALIZED ORACLE EMC XtremSF, EMC XtremCache, EMC Symmetrix VMAX and Symmetrix VMAX 10K, XtremSF and XtremCache dramatically improve Oracle performance Symmetrix

More information

IBM System Storage DS8000 series (Machine types 2421, 2422, 2423, and 2424) delivers new security, scalability, and business continuity capabilities

IBM System Storage DS8000 series (Machine types 2421, 2422, 2423, and 2424) delivers new security, scalability, and business continuity capabilities , dated February 10, 2009 IBM System Storage DS8000 series (Machine types 2421, 2422, 2423, and 2424) delivers new security, scalability, and business continuity capabilities Table of contents 1 At a glance

More information

Oracle Database 10g Resource Manager. An Oracle White Paper October 2005

Oracle Database 10g Resource Manager. An Oracle White Paper October 2005 Oracle Database 10g Resource Manager An Oracle White Paper October 2005 Oracle Database 10g Resource Manager INTRODUCTION... 3 SYSTEM AND RESOURCE MANAGEMENT... 3 ESTABLISHING RESOURCE PLANS AND POLICIES...

More information

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V

EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V IMPLEMENTATION GUIDE EMC VSPEX FOR VIRTUALIZED MICROSOFT EXCHANGE 2013 WITH MICROSOFT HYPER-V EMC VSPEX Abstract This describes the steps required to deploy a Microsoft Exchange Server 2013 solution on

More information

WHITE PAPER: ENTERPRISE AVAILABILITY. Introduction to Adaptive Instrumentation with Symantec Indepth for J2EE Application Performance Management

WHITE PAPER: ENTERPRISE AVAILABILITY. Introduction to Adaptive Instrumentation with Symantec Indepth for J2EE Application Performance Management WHITE PAPER: ENTERPRISE AVAILABILITY Introduction to Adaptive Instrumentation with Symantec Indepth for J2EE Application Performance Management White Paper: Enterprise Availability Introduction to Adaptive

More information

IMPROVING THE PERFORMANCE, INTEGRITY, AND MANAGEABILITY OF PHYSICAL STORAGE IN DB2 DATABASES

IMPROVING THE PERFORMANCE, INTEGRITY, AND MANAGEABILITY OF PHYSICAL STORAGE IN DB2 DATABASES IMPROVING THE PERFORMANCE, INTEGRITY, AND MANAGEABILITY OF PHYSICAL STORAGE IN DB2 DATABASES Ram Narayanan August 22, 2003 VERITAS ARCHITECT NETWORK TABLE OF CONTENTS The Database Administrator s Challenge

More information

Technical Notes. Considerations for Choosing SLC versus MLC Flash P/N REV A01. January 27, 2012

Technical Notes. Considerations for Choosing SLC versus MLC Flash P/N REV A01. January 27, 2012 Considerations for Choosing SLC versus MLC Flash Technical Notes P/N 300-013-740 REV A01 January 27, 2012 This technical notes document contains information on these topics:...2 Appendix A: MLC vs SLC...6

More information

Dell EMC Service Levels for PowerMaxOS

Dell EMC Service Levels for PowerMaxOS Dell EMC Service Levels for PowerMaxOS Dell Engineering May 2018 1 Dell EMC Service Levels for PowerMaxOS H17108 Revisions Date May 2018 Description Initial release The information in this publication

More information

IBM InfoSphere Information Server Version 8 Release 7. Reporting Guide SC

IBM InfoSphere Information Server Version 8 Release 7. Reporting Guide SC IBM InfoSphere Server Version 8 Release 7 Reporting Guide SC19-3472-00 IBM InfoSphere Server Version 8 Release 7 Reporting Guide SC19-3472-00 Note Before using this information and the product that it

More information

IBM Exam C IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ]

IBM Exam C IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ] s@lm@n IBM Exam C4090-457 IBM Storwize V7000 Implementation V1 Version: 6.0 [ Total Questions: 78 ] Question No : 1 How many days can an external virtualization license be used for migration before incurring

More information

Hitachi Storage Adapter for VMware vcenter Operations Management Suite Dashboard User s Guide

Hitachi Storage Adapter for VMware vcenter Operations Management Suite Dashboard User s Guide Hitachi Storage Adapter for VMware vcenter Operations Management Suite Dashboard User s Guide FASTFIND LINKS Document Organization Software Version Getting Help Contents AS-312-03 All Rights Reserved,

More information

IBM System Storage DS8870 Release R7.3 Performance Update

IBM System Storage DS8870 Release R7.3 Performance Update IBM System Storage DS8870 Release R7.3 Performance Update Enterprise Storage Performance Yan Xu Agenda Summary of DS8870 Hardware Changes I/O Performance of High Performance Flash Enclosure (HPFE) Easy

More information

SAP Applications on IBM XIV System Storage

SAP Applications on IBM XIV System Storage SAP Applications on IBM XIV System Storage Hugh Wason IBM Storage Product Manager SAP Storage Market - Why is it Important? Storage Market for SAP is estimated at $2Bn+ SAP BW storage sizes double every

More information

Hitachi Storage Command Portal Software Version 6.4 Release Notes

Hitachi Storage Command Portal Software Version 6.4 Release Notes Hitachi Storage Command Portal Software Version 6.4 Release Notes Table of Contents About This Document... 1 Intended Audience... 1 Getting Help... 1 About This Release... 2 New Features and Important

More information

IBM Storwize V7000 Unified Real-time Compression (RtC) Best Practices

IBM Storwize V7000 Unified Real-time Compression (RtC) Best Practices IBM Storwize V7000 Unified Real-time Compression (RtC) Best Practices Andreas Baer ATS System Storage Europe Executive summary Start using RtC only after careful capacity planning and capacity contingency

More information

Performance Tuning the Oracle ZFS Storage Appliance for Microsoft Exchange 2013 ORACLE WHITE PAPER MARCH 2016

Performance Tuning the Oracle ZFS Storage Appliance for Microsoft Exchange 2013 ORACLE WHITE PAPER MARCH 2016 Performance Tuning the Oracle ZFS Storage Appliance for Microsoft Exchange 2013 ORACLE WHITE PAPER MARCH 2016 Table of Contents Introduction 2 Performance Tuning 3 Tuning the File System 4 Tuning the Oracle

More information

Online data migration to IBM SVC / Storwize from iscsi SAN storage controllers

Online data migration to IBM SVC / Storwize from iscsi SAN storage controllers Table of contents Getting started... 1 Configuring iscsi initiator on SVC and connecting IBM Storwize as an iscsi storage... 4 Configuring iscsi initiator on SVC and connecting Dell EqualLogic as an iscsi

More information

SysGauge SYSTEM MONITOR. User Manual. Version 3.8. Oct Flexense Ltd.

SysGauge SYSTEM MONITOR. User Manual. Version 3.8. Oct Flexense Ltd. SysGauge SYSTEM MONITOR User Manual Version 3.8 Oct 2017 www.sysgauge.com info@flexense.com 1 1 SysGauge Product Overview SysGauge is a system and performance monitoring utility allowing one to monitor

More information

Hands-on Lab Session 9909 Introduction to Application Performance Management: Monitoring. Timothy Burris, Cloud Adoption & Technical Enablement

Hands-on Lab Session 9909 Introduction to Application Performance Management: Monitoring. Timothy Burris, Cloud Adoption & Technical Enablement Hands-on Lab Session 9909 Introduction to Application Performance Management: Monitoring Timothy Burris, Cloud Adoption & Technical Enablement Copyright IBM Corporation 2017 IBM, the IBM logo and ibm.com

More information

PRECISE SAP LITE PERFORMANCE ASSESSMENT

PRECISE SAP LITE PERFORMANCE ASSESSMENT PRECISE SAP LITE PERFORMANCE ASSESSMENT SAP Performance Advisor Copyright 2012 Precise Software Solutions, Inc. All rights reserved. Page 1 of 9 Overview Using Precise for SAP, we can quickly identify

More information

EMC VNX2 Deduplication and Compression

EMC VNX2 Deduplication and Compression White Paper VNX5200, VNX5400, VNX5600, VNX5800, VNX7600, & VNX8000 Maximizing effective capacity utilization Abstract This white paper discusses the capacity optimization technologies delivered in the

More information

EMC Celerra Manager Makes Customizing Storage Pool Layouts Easy. Applied Technology

EMC Celerra Manager Makes Customizing Storage Pool Layouts Easy. Applied Technology EMC Celerra Manager Makes Customizing Storage Pool Layouts Easy Applied Technology Abstract This white paper highlights a new EMC Celerra feature that simplifies the process of creating specific custom

More information

Implementing Pure Storage with IBM SAN Volume Controller. Simon Dodsley, Global Solutions Architect

Implementing Pure Storage with IBM SAN Volume Controller. Simon Dodsley, Global Solutions Architect Implementing Pure Storage with IBM SAN Volume Controller Simon Dodsley, Global Solutions Architect Version: 2.2 16 April 2018 Contents Notices... 3 Summary... 4 Audience... 4 Prerequisites... 4 Preparation

More information

MCSE Productivity. A Success Guide to Prepare- Core Solutions of Microsoft SharePoint Server edusum.com

MCSE Productivity. A Success Guide to Prepare- Core Solutions of Microsoft SharePoint Server edusum.com 70-331 MCSE Productivity A Success Guide to Prepare- Core Solutions of Microsoft SharePoint Server 2013 edusum.com Table of Contents Introduction to 70-331 Exam on Core Solutions of Microsoft SharePoint

More information

Storwize V7000 real-time compressed volumes with Symantec Veritas Storage Foundation

Storwize V7000 real-time compressed volumes with Symantec Veritas Storage Foundation Storwize V7000 real-time compressed volumes with Symantec Veritas Storage Foundation Demonstrating IBM Storwize V7000 advanced storage efficiency in a Veritas Storage Foundation environment John Cooper

More information

REFERENCE ARCHITECTURE Microsoft SQL Server 2016 Data Warehouse Fast Track. FlashStack 70TB Solution with Cisco UCS and Pure Storage FlashArray//X

REFERENCE ARCHITECTURE Microsoft SQL Server 2016 Data Warehouse Fast Track. FlashStack 70TB Solution with Cisco UCS and Pure Storage FlashArray//X REFERENCE ARCHITECTURE Microsoft SQL Server 2016 Data Warehouse Fast Track FlashStack 70TB Solution with Cisco UCS and Pure Storage FlashArray//X FLASHSTACK REFERENCE ARCHITECTURE September 2018 TABLE

More information

SCREEN COMBINATION FEATURE IN HATS 7.0

SCREEN COMBINATION FEATURE IN HATS 7.0 SCREEN COMBINATION FEATURE IN HATS 7.0 This white paper provides details regarding screen combination feature in HATS 7.0. What is Screen combination in HATS 7.0? HATS 7.0 can combine together multiple

More information

IBM Infrastructure Suite for z/vm and Linux: Introduction IBM Tivoli OMEGAMON XE on z/vm and Linux

IBM Infrastructure Suite for z/vm and Linux: Introduction IBM Tivoli OMEGAMON XE on z/vm and Linux IBM Infrastructure Suite for z/vm and Linux: Introduction IBM Tivoli OMEGAMON XE on z/vm and Linux August/September 2015 Please Note IBM s statements regarding its plans, directions, and intent are subject

More information