1 page 1/237 Direction des Recherches et des Développements VELIZY R&D Center Etablissement de VELIZY NOTE D'ETUDE / TECHNICAL DOCUMENT TITRE / TITLE : AT Command Set for SAGEM Modules RESUME / SUMMARY T his document presents the AT Command Set of the SAGEM Commmunications : MO200, XS200, MO300 and XS300 modules. The document is derived from SCT TMO MOD SPEC 0465 J - AT Command Set for SAGEM Modules.doc and has been updated to take into account MO/XS300 new commands. Note d étude / Technical document : URD / Edition 05

2 page 2/237 Direction des Recherches et des Développements VELIZY R&D Center Etablissement de VELIZY NOTE D'ETUDE / TECHNICAL DOCUMENT FICHE RECAPITULATIVE / SUMMARY SHEET Ed Date Référence Observations Date 1 04/07/2007 URD /09/2007 URD /10/2007 URD /11/2007 URD /11/2007 URD Comments Création du document / Document creation Mises à jour / Updates Mises à jour / Updates Mises à jour / Updates Ajout commandes file system / file system commands added, updates on VIP, KRST, IPR 7 Note d étude / Technical document : URD / Edition 05

3 page 3/237 Direction des Recherches et des Développements VELIZY R&D Center Etablissement de VELIZY SOMMAIRE / CONTENTS 1. INTRODUCTION Scope of the document Supported product documents AT Command principle Possible answers Multiple AT commands on the same command line AT Commands on separate lines Modification of this document V25TER AT COMMANDS A/ Command: Repeat previous command line Command : Switch from data mode to command mode O Command : Switch from command mode to data mode E Command : Enable command echo Q Command : Set result code presentation mode S0 Command : Set number of rings before automatically answering the call S2 Command : Set character for the escape sequence (data to command mode) S3 Command : line termination character S4 Command : Set response formatting character S5 Command : line editing character S7 Command : Set number of seconds to wait for connection completion V Command : Set result code format mode X Command : Set CONNECT result code format and call monitoring &C Command : Set circuit Data Carrier Detect (DCD) function mode &D Command : Set circuit Data Terminal Ready (DTR) function mode &F Command : Restore manufactory configuration &W Command : Save stored profile &V Command : Display current configuration IPR and +KIPR Commands : Set fixed local rate B: Data rate selection \N: Data transmission mode &K0 Command : No flow control command &K3 Command : Hardware flow control command &K4 Command : Software flow control command GENERAL AT COMMANDS I Command : Request Identification Information Z Command : Reset and restore user configuration CGMI Command : Request manufacturer identification CGMM Command : Request model identification CGMR Command : Request revision identification CGSN Command : Request product serial number identification (IMEI) identical to GSN KGSN Command : Request product serial number identification and Software Version...29 Note d étude / Technical document : URD / Edition 05

4 Note d étude / Technical document : URD / Edition 05 page 4/ KSGV Command : Read creation/modification date of SGV file CSCS Command : Set TE character set CIMI Command : Request international subscriber identity GCAP Command : Request complete TA capability list GMI Command : Request manufacturer identification GMM Command : Request model identification GMR Command : Request revision identification GSN Command : Request product serial number identification (IMEI) identical to GSN %V Command : Request model identification KICC Command : Request the integrated circuit card identification CMUX Command : Multiplexing mode KSRAND Command : Random Number Calculation CALL CONTROL COMMANDS A Command : Answer a call H Command : Disconnect existing connection D Command : Mobile originated call to dial a number D> : Direct dialing from phonebook CHUP Command : Hang up call CSNS Command : Single Numbering Scheme CRC Command : Set Cellular Result Codes for incoming call indication MOBILE EQUIPMENT CONTROL AND STATUS COMMANDS CACM Command : Accumulated call meter (ACM) reset or query CAMM Command : Accumulated call meter maximum (ACM max) set or query CCWE Command : Call Meter maximum event CALA Command : Set alarm time CALD Command : Delete alarm CCLK Command : Real time clock CPOF Command : Power off CIND Command : Indicator control SIM notification : Hardware detection CLAC Command : List all available AT commands CMEC Command : Mobile Equipment control mode CDIS Command : Display Control CKPD Command : Keypad Control CFUN Command : Set Phone Functionality CMER Command : Mobile Equipment event reporting CMEE Command : Report Mobile Termination error CMUT Command : Mute control CPIN Command : Enter pin KPINNB Command : Remaining PIN code entrance attempts CPUC Command : Price per unit and currency table CPWC Command : Power class KBND Command : Change Frequency Band CPAS Command : Phone Activity Status CSQ Command : Signal quality KRIC Command : Ring indicator control KDSIM Command : Unlock mobile KSREP Command : Mobile start-up reporting KGPIO Command : Hardware IO Control KSLEEP Command : Power Management Control KCELL Command : Cell Environment Information CRMC Command : Ring Melody Control CRMP Command : Ring Melody Playback KVMAIL Command : Voice Mail indicator CRSM Command : SIM Restricted Access KGPIOCFG Command: user GPIO configuration AT+KPWM: Led management...73

5 Note d étude / Technical document : URD / Edition 05 page 5/ AT+KRST : Periodic reset AT+KANT : Antenna detection AT+KADC : Analog digital converter AT+KTMP : Temperature measurement NETWORK SERVICE RELATED COMMANDS CAOC Command : Advice of charge information CCFC Command : Call forwarding number and conditions control CCWA Command : Call waiting CHLD Command : Call hold and multiparty CUSD: Unstructured Supplementary Service Data CLCC Command : List current call CLCK Command : Facility lock CLIP Command : Calling line identification presentation CLIR Command : Calling line identification restriction CNUM Command : Subscriber number COLP Command : Connected line identification presentation COPN Command : Read operator name COPS Command : Operator selection CPOL Command : Preferred PLMN list CPWD Command : Change password CREG Command : Network registration CSSN Command : Supplementary service notification PHONE BO MANAGEMENT CPBF Command : Find phonebook entries CPBR Command : Read current phonebook entries CPBS Command : Select phonebook memory storage CPBW Command : Write phonebook entries SMS AT COMMANDS Preliminary comment definition CMGD Command : Delete SMS message CMGF Command : Select SMS message format CMGL Command : List SMS messages from preferred store CMGR & +KMGR Command : Read SMS message CMGS Command : Send SMS message CMGW Command : Write SMS message to memory CMSS Command : Send SMS message from storage CNMI Command : New SMS message indication CSCB Command : Select cell broadcast message CSCA Command : SMS service center address CSMP Command : Set SMS text mode parameters CSMS Command : Select Message service CPMS Command : Preferred Message Storage CSDH Command : Show text mode parameters CSAS Command : Save settings CRES Command : Restore settings DATA AND FAX AT COMMANDS CBST Command : Select bearer service type CRLP Command : Select radio link protocol parameter CR Command : Service reporting control FCLASS Command : Fax : Select, read or test service class FAE Command : Data/Fax auto answer FRM Command : Receive data FTM Command : Transmit data FRS Command : Receive silence...125

6 Note d étude / Technical document : URD / Edition 05 page 6/ FTS Command : Stop transmission and wait FRH Command : Receive data using HDLC framing FTH Command : Transmit data using HDLC framing GPRS AT COMMANDS CGATT Command : PS Attach or Detach CGACT Command : PDP context activate or deactivate CGCLASS Command : GPRS mobile station class CGDCONT Command : Define PDP context CGDATA Command : Enter data state CGEREP Command : GPRS event reporting CGPADDR Command : Show PDP address CGQMIN Command : Quality of service profile (minimum acceptable) CGQREQ Command : : Request quality of service profile CGREG Command : GPRS network registration status KMCLASS : Change GPRS Multislot class SIM APPLICATION TOOLKIT AT COMMANDS Preliminary comments KSTIA Command : Access to an instance of an icon KSTIR Command : Get a data block of an icon instance KSTIS Command : List of instances of an icon KSTF Command : Type error KSTR Command : Terminal response KSTP Command : Profile supported by the DTE KSTV Command : Envelope command KSTART Command : Activation of the KSTC notification KSTC notification: SIM Application Toolkit command KSTE notification: End of a command KSTER notification: to an envelope command KSTS notification: Session Status AUDIO COMMANDS CLVL Command : Loudspeaker volume level VIP Command : InitialiZe Voice VTS Command : DTMF and Tone generation VLS Command : Line Selection VTD Command : Tone duration VGR Command : Received gain selection VGT Command : Transmit gain selection KECHO Command : Echo Cancellation AT+KDAISTP: Set up DAI interface MMS COMMANDS* Command set overview Automatic retrieval Examples MMS PDU The parameter <index> KPSV Command: Version of the synchronization command set KMMCNF Command: MMS Configuration KPSL Command: List of Objects KPSR Command: Reading an Object KPSW Command: Writing an object KPSD Command: Deleting an Object KPSSEND Command: Send MMS KPSCAP Command: Retrieving MOBILE capabilities KMMRET Command: Retrieve MMS KMMA : MMS In MMSC notification...169

7 Note d étude / Technical document : URD / Edition 05 page 7/ KMMREC : MMS in ME notification PROTOCOL SPECIFIC COMMANDS Preliminary comments CONNECTION CONFIGURATION KCNXCFG: GSM Connection Configuration KCNXCFG: GPRS Connection Configuration Configuration +KCNXTIMER: Connection Timer Configuration KCNXPROFILE: Connection current profile configuration TCP Specific Commands KTCPCFG: TCP Connection Configuration KTCPCNX: TCP Connection KTCP_DATA: Incoming data through a TCP Connection KTCPRCV: Receiving data through a TCP Connection KTCPSND: Sending data through a TCP Connection KTCPCLOSE: Closing current TCP operation FTP Specific Commands KFTPCFG: FTP Configuration KFTPRCV: Downloading FTP files KFTPSND: Uploading FTP files KFTPDEL: Deleting FTP files KFTPCLOSE: Ending current FTP connection UDP Specific Commands KUDPCFG: UDP Connection Configuration KUDPCLOSE: Closing current UDP operation KUDPSND: Sending data through an UDP Connection KUDPRCV: Receiving data through an UDP Connection SMTP Specific Commands KSMTPPARAM: Connection Configuration KSMTPPWD: Authentication Configuration KSMTPTO: Receivers Configuration KSMTPSUBJECT: Subject Configuration KSMTPUL: Send Message KSMTPCLEAR: Clear Specific Error Code For The SMTP Commands POP3 Specific Commands KPOPCNX: Connection Configuration KPOPLIST: List Available Mail KPOPREAD: Download A Mail KPOPDEL: Delete A Mail KPOPQUIT: Close Connection Specific Error Code For POP3 Commands SPECIFIC FLASH COMMANDS Read Flash command Write Flash command File management command File system management command OTHER SPECIFIC COMMANDS APPENDIX 1. SAGEM S.A. INTERNAL COMMANDS APPENDIX 2. RESULT CODES AND UNSOLICITED MESSAGES APPENDIX 3. ERROR CODES A3.1. CME ERROR codes A3.2. CMS ERROR codes A3.3. GPRS ERROR codes...215

8 page 8/237 APPENDIX 4. APPENDIX 5. PIN CODE REQUIREMENT GSM MULTIPLEXING PROTOCOL APPENDIX 6. SET OF COMMANDS SUPPORTED BY EACH MODULE APPENDIX 7. HOW TO USE TCP SPECIFIC COMMANDS APPENDIX 8. HOW TO USE FTP SPECIFIC COMMANDS APPENDIX 9. HOW TO USE UDP SPECIFIC COMMANDS APPENDIX 10. HOW TO USE MAIL SPECIFIC COMMANDS A10.1. Mail Overview A Mail Layout A Mail Header A Mail Body A10.2. Mail Attachement A Multipart Message A Attachment Format A10.3. How To Use SMTP Specific Commands A Simple Mode A Complex Mode A10.4. How To Use POP3 Specific Commands APPENDIX 11. HOW TO USE MMS SPECIFIC COMMANDS APPENDIX 12. HOW TO USE SIM TOOLKIT APPENDIX 13. HOW TO SWITCH FROM DATA MODE TO COMMAND MODE Note d étude / Technical document : URD / Edition 05

9 page 9/ INTRODUCTION 1.1. Scope of the document This document presents the AT Command Set of the SAGEM SA MO200, XS200, MO300 and XS300 modules. Each AT command is described and if necessary the standard reference is noted. (e.g.: ] 7.5). Some AT command are SAGEM SA proprietary: in this case it is clearly indicated Supported product Please refer to the table of the appendix 6 which synthesize the AT commands supported by each module documents [04.08] GSM (6.7.1) Mobile radio interface layer 3 specification (Release 1997) [22.022] 3GPP (3.1.0) - Personalization of Mobile Equipment (ME); Mobile functionality specification (Release 1999) [27.005] 3GPP (5.0.0) Equipment (DTE - DCE) interface for Short Message Service (SMS) and Cell Broadcast Service (CBS) [27.007] 3GPP (6.0.0) - AT command set for User Equipment (UE) (Release 6) [V24] [V25ter] [STK] [SIM] Recommandation UIT-T V.24 - Liste des définitions des circuits de jonction entre l'équipement terminal de traitement de données et l'équipement de terminaison du circuit de données ITU-T Recommendation V.25 ter - Serial asynchronous automatic dialing and control Interface Requirements specification for AT Commands of the SIM Application Toolkit on MO190 Specification of the Subscriber Identity Module Mobile Equipment (SIM ME) interface. (GSM version Release 1999) [HW] Module MO190 Hardware specification (SCT TMO MOD SPEC 058) 1.4. AT Command principle The AT or at prefix must be set at the beginning of each line. To terminate a command line, a <CR> character must be inserted. Note d étude / Technical document : URD / Edition 05

10 page 10/237 Commands are usually followed by a response that includes <CR><LF><response><CR><LF>. Throughout this document, only the responses are indicated, the <CR> and <LF> characters are omitted intentionally. Comment: The TA can be setup to replace <CR> and <LF> with other characters (see ATS3 and ATS4 commands) Four kinds of extended AT commands are implemented: Test Command AT+CXXX=? The equipment returns the list of parameters and values ranges set with the with the corresponding or by internal processes. Read Command AT+CXXX? This command returns the currently set value of parameters. Write Command AT+CXXX=< > This command sets user-related parameter values. Execution command AT+CXXX The execution command reads nonvariable parameters affected by internal processes in the equipment In this document, the default parameters are underlined and the optional parameters are enclosed in square brackets. Optional parameters or sub-parameters can be omitted unless they are followed by other parameters. A parameter in the middle of a string can be omitted by replacing it with a comma. When the parameter is a character string, the string must be enclosed in quotation marks. All space characters will be ignored when using strings without quotation marks Possible answers There is always an answer sent by the TA to an AT Command line (except the very special case of a TA setup for no answer, see ATQ). The answer is always terminated by an indication of success or failure. However, regarding the setup of the TA (by AT Commands), the message may be different. Classical messages: Extended Error message (see AT+CMEE) : or ERROR +CME ERROR: <n> (see Appendix for the different values for <n>) Numeric Mode (see ATV): <n> with: <n> = 0 or <n> is an error code Multiple AT commands on the same command line You may enter several AT commands on the same line. This eliminates the need to type the "AT" or "at" prefix before each command and to wait for the answer for each command. The main advantage is to avoid loosing bandwidth on the link between DTE and the Module. Note d étude / Technical document : URD / Edition 05

11 page 11/237 There is no separator between two basic commands but a semi-colon character is necessary between two extended commands (prefix +). The command line buffer accepts a maximum of 391 characters. If this number is exceeded none of the commands will be executed and TA returns ERROR. If a command is not supported, then the treatment of the line is stopped (i.e. the following ones are not treated) and an error message is returned. Example: Command: Answer: ATZ&K3+CBST=7,0,1;+CBST? +CBST=7,0,1 Note d étude / Technical document : URD / Edition 05

12 page 12/ AT Commands on separate lines When you enter a series of AT commands on separate lines, it is strongly advised to leave a pause between the preceding and the following command until the final answer ( or Error message) appears. This avoids sending too many AT commands at a time without waiting for a response for each Modification of this document The commands described in this document are subject to change without notice, and shall only be used as a for usual AT commands use. Note d étude / Technical document : URD / Edition 05

13 page 13/ V25TER AT COMMANDS 2.1. A/ Command: Repeat previous command line A/ Repeat previous command line Execute command A/ Depend on the previous command None V.25Ter Line does not need to end with terminating character Command : Switch from data mode to command mode +++ Switch from data mode to command mode Execute command +++ This command is only available during data calls. The +++ characters sequence causes to cancel de data flow over the AT interface and switch to command mode. This allows to enter AT commands while maintaining the data connection to the remote device. None V.25Ter To return to data mode, use the ATO command Line does not need to end with terminating character The + character may be changed with the ATS2 command (see following chapters) Note d étude / Technical document : URD / Edition 05

14 page 14/ O Command : Switch from command mode to data mode ATO Switch from command mode to data mode ATO[n] TA returns to data mode from command mode: CONNECT <text> If connection is not successfully resumed NO CARRIER Parameter <n> 0 switch from command mode to data mode GSM ATO is the alternative command to the +++ escape sequence described in Chapter 2.2: When you have established a data call and TA is in command mode, ATO causes the TA to resume the data connection and return to data mode E Command : Enable command echo ATE Enable command echo Execute command ATE[<value>] <value> : 0 Echo mode off 1 Echo mode on V.25Ter This setting determines whether or not the TA echoes characters received from TE during command state Note d étude / Technical document : URD / Edition 05

15 page 15/ Q Command : Set result code presentation mode ATQ Set result code presentation mode Execute command ATQ[<n>] (if <n> = 0) Nothing (if <n> = 1) <n> 0: result codes transmitted by TA 1: no result code transmitted by TA V.25Ter Specifies whether or not the TA transmits any result code to the TE. Information text transmitted in response is not affected by this setting S0 Command : Set number of rings before automatically answering the call ATS0 Set number of rings before automatically answering the call ATS0? <n> ATS0=<n> <n>: 0: automatic answering deactivated 1-255: number of rings before automatically answering V.25ter This command is valid only for data calls 2.7. S2 Command : Set character for the escape sequence (data to command mode) Note d étude / Technical document : URD / Edition 05

16 page 16/237 ATS2 Set character for the escape sequence (data to command mode) ATS2? <n> ATS2=<n> <n>: : command line termination character V.25ter The default character is + (043) and cannot be changed : this command returns, but do not take in account the value change request S3 Command : line termination character ATS3 line termination character write command ATS3[<n>] <n> : command line termination character ATS3? V.25Ter <n> This parameter determines the character recognized by TA to terminate an incoming command line (13 = <CR> by default); it cannot be changed : this command returns, but do not take in account the value change request. Note d étude / Technical document : URD / Edition 05

17 page 17/ S4 Command : Set response formatting character ATS4 Set response formatting character ATS4[<n>] <n> : response formatting character ATS4? V.25Ter <n> This parameter determines the character recognized by TA to terminate answer line (10 = <LF> by default); it cannot be changed : this command returns, but do not take in account the value change request S5 Command : line editing character ATS5 line editing character write command ATS5[<n>] <n> command line editing character ATS5? V.25Ter <n> This parameter determines the character recognized by TA to terminate an incoming command line (8 = <backspace> by default); it cannot be changed : this command returns, but do not take in account the value change request. Note d étude / Technical document : URD / Edition 05

18 2.11. S7 Command : Set number of seconds to wait for connection completion page 18/237 ATS7 Set number of seconds to wait for connection completion ATS7=<n> : : <n>: number of second to wait for connection completion ATS7? : <n> : None V.25Ter See also AT&V for default values of this parameter V Command : Set result code format mode ATV Set result code format mode Execute command ATV[<value>] 0 (When numeric mode activated) (When verbose mode activated) <value> : 0 Information response: <text><cr><lf> Short result code format: <numeric code><cr> 1 Information response: <CR><LF><text><CR><LF> Long result code format: <CR><LF><verbose code><cr><lf> V.25Ter This parameter setting determines the contents of the header and trailer transmitted with result codes and information responses X Command : Set CONNECT result code format and call monitoring Note d étude / Technical document : URD / Edition 05

19 page 19/237 ATX Set CONNECT result code format and call monitoring ATX[<value>] <value>: 0 : CONNECT result code only returned, dial tone and busy detection are both disabled 1 : CONNECT<text> result code only returned, dial tone and busy detection are both disabled 2 : CONNECT<text> result code returned, dial tone detection is enabled, busy detection is disabled 3 : CONNECT<text> result code returned, dial tone detection is disabled, busy detection is enabled 4 : CONNECT<text> result code returned, dial tone and busy detection are both enabled V.25Ter &C Command : Set circuit Data Carrier Detect (DCD) function mode AT&C Set circuit Data Carrier Detect (DCD) function mode Execute command AT&C[<value>] <value> 0 : DCD line is always active 1 : DCD line is active in the presence of data carrier only. V.25Ter Note d étude / Technical document : URD / Edition 05

20 page 20/ &D Command : Set circuit Data Terminal Ready (DTR) function mode AT&D Set circuit Data Terminal Ready (DTR) function mode Execute command AT&D[<value>] <value>: 0: TA ignores status on DTR. 1: Active->Inactive on DTR: Change to command mode while retaining the connected data call. 2: Active->Inactive on DTR: Disconnect data call, change to command mode. During state DTR inactive auto-answer is off. V.25Ter The command AT&D only applies to data calls. Thus, a DTR drop from active to inactive in AT&D2 mode will not hang up a voice call &F Command : Restore manufactory configuration AT&F Restore Manufactory configuration Execute command AT&F[<value>] <value>: 0: Restore parameters to manufactory values V.25Ter See also AT&V Note d étude / Technical document : URD / Edition 05

21 page 21/ &W Command : Save stored profile AT&W Save stored profile Execute command AT&W SAGEM SA Proprietary This commands saves the current configuration in a non erasable place See also AT&V The default stored profile may be adapted for customer needs (see SAGEM S.A. if request on this subject) Configuration saved : FLOW CONTROL (at&k) DTR (&D) ECHO MODE (ate) RLP MODE VERBOSE (atv) CIRCUIT DATA DETECT (at&c) SET RESULT CODE PRESENTATION MODE (at&q) CLIP MODE COLP MODE CREG MODE CSSI CSSU CRC MODE CSNS MODE CMEE CMER SET NUMBER OF RINGS BEFORE AUTOMATICALLY ANSWERING THE CALL (S0 COMMAND) SET CHARACTER FOR THE ESCAPE SEQUENCE (DATA TO COMMAND MODE) (S2 COMMAND) SET NUMBER OF SECONDS TO WAIT FOR CONNECTION COMPLETION (S7 COMMAND) MODE TEXT FOR SMS (CMGF) KSREP KRIC KSLEEP CNMI VGR VGT KECHO CWA CAOC Note d étude / Technical document : URD / Edition 05

22 page 22/ &V Command : Display current configuration AT&V Display current configuration Execute command AT&V[<value>] ACTIVE PROFILE: <current configuration> STORED PROFILE: <user default configuration> DEFAULT SETTINGS: <manufactory configuration> <value>: 0: only active profile 1: only stored profile 2: only default profile SAGEM SA Proprietary The configuration is a text string on multiple lines as shown in the example below. This string may vary depending on the manufactory, the product and the user setup. Example: B13 \N4 E1 Q0 V1 X1 \V0 +CMEE0 +CMGF0 +FCLASS0 S00:000 S02:043 S03:013 S04:010 S05:008 S07:050 &K0 &D2 &C1 +CCCM1 +CCWA0 +CLIP1 +COLP0 +CREG1 +CR0 +CRC1 +CSSI0 +CSSU0 +CMER0 +CKEV0 +CIEV0 +CSNS0 +CCWV0 +VGR0 +VGT0 +KECHO0 This command indicates the result of certain actions as shown below: Active Profile ATZ AT&W AT&F Stored Profile Default Settings Note d étude / Technical document : URD / Edition 05

23 page 23/ IPR and +KIPR Commands : Set fixed local rate AT+IPR and AT+KIPR Set fixed local rate AT+IPR=? +IPR: (list of supported auto-detectable <rate>s), (list of supported fixed-only <rate>s) AT+IPR? +IPR:<rate> AT+IPR=<rate> or if error is related: ERROR /+CME ERROR: <err> <rate>: bit rate per second 1200, 2400, 4800, , 38400, 57600, , , = autobaud V.25ter (+IPR) SAGEM SA Proprietary (+KIPR) AT+IPR and AT+KIPR are only relevant for UART connectivity but not for USB connectivity. The speed is modified after sending the answer AT+KIPR changes the speed temporarily, previous value is restored after a power on/off and baud rates are only available for MO300 and XS300 models. Note d étude / Technical document : URD / Edition 05

24 page 24/ B: Data rate selection ATB Data Rate Selection Execute Command ATB<rate> <rate>: 7: Analogic Modem 2400 (V22Bis) 11: Analogic Modem 4800 (V32) 13: Analogic Modem 9600 (V32) 25: UDI 2400 ISDN 27: UDI 4800 ISDN 29: UDI 9600 ISDN V.25ter It is recommended to use AT+CBST instead of this command \N: Data transmission mode AT\N Data Transmission Mode Execute Command AT\N<x> <x>: 0: transparent mode 4, 6: RLP mode (non transparent) V.25ter It is recommended to use AT+CBST instead of this command Note d étude / Technical document : URD / Edition 05

25 page 25/ &K0 Command : No flow control command AT&K0 No flow control command Execute command AT&K0 V.25ter Disable the flow control of the serial interface Use AT&V0 to display the current flow control setting &K3 Command : Hardware flow control command AT&K3 Hardware flow control command Execute command AT&K3 Enable the hardware flow control of the serial interface Use AT&V0 to display the current flow control setting &K4 Command : Software flow control command AT&K4 Software flow control command Execute command AT&K4 V.25ter Enable the software flow control of the serial (mode Xon/Xoff) Use AT&V0 to display the current flow control setting Note d étude / Technical document : URD / Edition 05

26 page 26/ GENERAL AT COMMANDS 3.1. I Command : Request Identification Information ATI Request identification information Execute command ATI[<value>] <text> (depends on <value>) Parameter <value> : nothing: Product name 0: Product name 3: Software version V.25ter <text> may take more than one line 3.2. Z Command : Reset and restore user configuration ATZ Reset and restore user configuration Execute command ATZ[<value>] Parameter <value> : 0 V.25ter See also AT&V Note d étude / Technical document : URD / Edition 05

27 page 27/ CGMI Command : Request manufacturer identification AT+CGMI Request manufacturer identification AT+CGMI=? Execute command AT+CGMI [27.007] 5.1 +CGMI: SAGEM (manufacturer identification text) The module return ERROR on a read command (AT+CGMI?) CGMM Command : Request model identification AT+CGMM Request model identification AT+CGMM=? Execute command AT+CGMM +CGMM: MO xxx (model identification text) [27.007] 5.2 The module return ERROR on a read command (AT+CGMM?) Note d étude / Technical document : URD / Edition 05

28 page 28/ CGMR Command : Request revision identification AT+CGMR Request revision identification AT+CGMR=? Execute command AT+CGMR +CGMR: SAGEM xxxxxx (model revision identification text) [27.007] 5.3 The module return ERROR on a read command (AT+CGMR?) CGSN Command : Request product serial number identification (IMEI) identical to GSN AT+CGSN Request product serial number identification (IMEI) identical to GSN AT+CGSN=? Execute command AT+CGSN [27.007] 5.4 <sn> (identification text for determination of the individual ME) The module return ERROR on a read command (AT+CGSN?) Note d étude / Technical document : URD / Edition 05

29 page 29/ KGSN Command : Request product serial number identification and Software Version AT+KGSN Request product serial number identification (IMEI) AT+KGSN=? +KGSN: (list of supported <imei type>s) Execute command AT+KGSN=<imei type> If <imei type> = 0: +KGSN: <IMEI> If <imei type> = 1: +KGSN: < IMEISV> If <imei type> = 2: +KGSN: < IMEISV_STR> <IMEI>: 15 digits IMEI (8 digits for TAC + 6 digits for SNR + 1 check digit) <IMEISV>: 16 digits IMEISV (8 digits for TAC + 6 digits for SNR + 2 SVN digits) <IMEISV_STR>: formatted string : <15 digits>-<check digit> SV:<Software version> SAGEM S.A. proprietary This command has been developped to provide the IMEI SV through an AT Command Example AT+KGSN=0 +KGSN: AT+KGSN=1 +KGSN: Note d étude / Technical document : URD / Edition 05

30 page 30/ KSGV Command : Read creation/modification date of SGV file AT+KSGV Read Creation/Modification date for SGV file Execute command AT+KSGV +KSGV : <generation date>,<modification date> <generation date>: <modification date>: "hh:mm:dd:mm:yy" "hh:mm:dd:mm:yy" SAGEM S.A. proprietary This command is dedicated for OEM and allows to check the sgv file (audio setup) used in the module firmware. The 2 dates (generation and modification may be read with the SAGEM S.A. audio tool) CSCS Command : Set TE character set AT+CSCS Set TE character set AT+CSCS=? +CSCS: (list of supported <chset>) AT+CSCS? +CSCS: <chset> AT+CSCS=<chset> Parameter <chset> : GSM GSM default alphabet (GSM subclause 6.2.1) UCS2 16 bit universal multiple-octet coded character set (ISO/IEC 10646) IRA default value PCCP437 default value default value HEX default value [27.007] 5.5 Select the character set used for all string types (Phonebook entries, SMS data, ) Note d étude / Technical document : URD / Edition 05

31 page 31/ CIMI Command : Request international subscriber identity AT+CIMI Request international subscriber identity AT+CIMI=? Execute command AT+CIMI <IMSI> (International Mobile Subscriber Identify) Parameter [27.007] 5.6 The module return ERROR on a read command (AT+CIMI?) GCAP Command : Request complete TA capability list AT+GCAP Request complete TA capability list AT+GCAP=? Execute command AT+GCAP +GCAP: list of <name>s V.25ter Example: +GCAP: +CGSM, +FCLASS Note d étude / Technical document : URD / Edition 05

32 page 32/ GMI Command : Request manufacturer identification AT+GMI Request manufacturer identification AT+GMI=? Execute command AT+GMI V.25ter +GMI: SAGEM (manufacturer identification text) The module return ERROR on a read command (AT+GMI?) GMM Command : Request model identification AT+GMM Request model identification AT+GMM=? Execute command AT+GMM V.25ter +GMM: MO xxx (model identification text) The module return ERROR on a read command (AT+GMM?) Note d étude / Technical document : URD / Edition 05

33 page 33/ GMR Command : Request revision identification AT+GMR Request revision identification AT+GMR=? Execute command AT+GMR V.25ter +GMR: xxxxxx (model identification text) The module return ERROR on a read command (AT+GMR?) GSN Command : Request product serial number identification (IMEI) identical to GSN AT+GSN Request product serial number identification (IMEI) AT+GSN=? Execute command AT+GSN V.25ter <sn> (identification text for determination of the individual ME) The module return ERROR on a read command (AT+GSN?) Note d étude / Technical document : URD / Edition 05

34 page 34/ %V Command : Request model identification AT%V Request model identification Execute command AT%V MO xxx (model identification text) V.25ter Identical to +CGMM command KICC Command : Request the integrated circuit card identification AT+KICC Request the Integrated Circuit Card Identification AT+KICC=? Read Command AT+KICC? <ICC id> (Integrated Circuit Card Identification) SAGEM SA Proprietary The ICC Identification is returned even if the PUK1 is not entered The module returns ERROR on an execute (AT+KICC) and on a write (AT+KICC= ) command Note d étude / Technical document : URD / Edition 05

35 page 35/ CMUX Command : Multiplexing mode AT+CMUX Multiplexing Mode AT+CMUX=? +CMUX: (list of supported <mode>s),(list of supported <subset>s),(list of supported <port_speed>s),(list of supported <N1>s),(list of supported <T1>s),(list of supported <N2>s),(list of supported <T2>s),(list of supported <T3>s),(list of supported <k>s) Read Command AT+CMUX? +CMUX: <mode>,[<subset>],<port_speed>,<n1>,<t1>, <N2>,<T2>,<T3>[,<k>] AT+CMUX=<mode> [,<subset> [,<port_speed>[,<n1> [,<T1>[,<N2>[,<T2> [,<T3>]]]]]]] [27.007] 5.7 <mode>: multiplexer Transparency Mechanism 0: Basic option <subset>: 0 UIH frames used only 1 UI frames used only <port_speed>: transmission rate bit/s bit/s bit/s bit/s bit/s <N1>: maximum frame size (1-64) <T1>: <N2>: <T2>: <T3>: <k>: default Value : 31 (64 if Advanced option is used) acknowledgement timer in units of ten milliseconds 1-255, where 10 is default (100 ms) maximum number of re-transmissions 0-100, where 3 is default response timer for the multiplexer control channel in units of ten milliseconds 2-255, where 30 is default (300 ms) wake up response timer in seconds 1-255, where 10 is default window size, for Advanced operation with Error Recovery options 1-7, where 2 is default. Not supported in write command. Multiplexing protocol is described in 3 GPP TS See Chapter Appendix 5 for a summary of SAGEM S.A. support Note d étude / Technical document : URD / Edition 05

36 page 36/ KSRAND Command : Random Number Calculation AT+KSRAND Random Number Calculation AT+KSRAND=? +KSRAND : (0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255),(0-255) Read Command AT+ KSRAND? +KSRAND: <sres0>,<sres1>,<sres2>,<sres3>,<kc0>,<kc1>,<kc2>,<kc3>,<kc4>,<kc5>,<kc6>,<kc7> AT+KSRAND= <rand0>,<rand1>,<rand2>,< rand3>,<rand4>,<rand5>,<r and6>,<rand7>,<rand8>,<ra nd9>,<rand10>,<rand11>,<r and12>,<rand13>,<rand14>, <rand15> +KSRAND: <sres0>,<sres1>,<sres2>,<sres3>,<kc0>,<kc1>,<kc2>,<kc3>,<kc4>,<kc5>,<kc6>,<kc7> <sres i >: <rand i >: 4 bytes value 8 bytes value SAGEM S.A. Proprietary This AT command takes 16 bytes as parameters. It calls the A3-A8 SIM algorithm to obtain SRES (4 bytes long) and KC (8 bytes long). Note d étude / Technical document : URD / Edition 05

37 page 37/ CALL CONTROL COMMANDS 4.1. A Command : Answer a call ATA Answer a call Execute command ATA : CONNECT[<text>] NO CARRIER Data Connexion established Voice Connexion established or if cancellation of the command if no connection V.25Ter See ATX for setup of the CONNECT message 4.2. H Command : Disconnect existing connection ATH Disconnect existing connection Execute command ATH[n] : : <n: 0 terminate call V.25Ter On this command, all calls in progress are ended See also AT+CHLD Note d étude / Technical document : URD / Edition 05

38 page 38/ D Command : Mobile originated call to dial a number ATD Mobile originated Call to dial a number Execute command ATD[<n>][;] : NO DIALTONE BUSY NO CARRIER NO ANSWER CONNECT[<text>] The connection cannot be established Data connection successfully connected If successfully connected and voice call : <n>: String of dialing digits and optionally V.25ter modifiers (dialing digits): 0-9, *, #, +, A, B, C (maximum length: 20 digits) <;>: Only required to set up voice calls. TA remains in command mode. V.25Ter The command may be aborted generally when receiving an ATH command during execution Same behavior for ATDP, ATDR, ATDT, ATPD, ATRD, ATTD answer may arrive after just after the ATD command or after the call is actually active (see AT+COLP, chapter 6.11) 4.4. D> : Direct dialing from phonebook ATD> Direct dialing from phonebook Execute command ATD><str>[;] ATD>[<mem>]<n>[;] See ATD : <str>: alphanumeric field (if possible all available memories should be searched for correct entry) <mem>: memory storage (ME, SM ) <n>: entry location [27.007] 6.2 For memory storage locations, see AT+CPBS Note d étude / Technical document : URD / Edition 05

39 page 39/ CHUP Command : Hang up call AT+CHUP Hang up call Execute command AT+CHUP AT+CHUP=? [27.007] 6.5 AT+CHUP has the same behavior as ATH (i.e. ends all calls in progress) CSNS Command : Single Numbering Scheme AT+CSNS Single Numbering Scheme AT+CSNS=? +CSNS: (list of supported <mode>) AT+CSNS? +CSNS:<mode> AT+CSNS=[<mode>] [27.007] 6.19 <mode>: 0: Voice 2: Fax 4: Data See also AT+CBST Note d étude / Technical document : URD / Edition 05

40 4.7. +CRC Command : Set Cellular Result Codes for incoming call indication page 40/237 AT+CRC Set Cellular Result Codes for incoming call indication AT+CRC=? +CRC: (list of supported <mode>) AT+CRC? +CRC:<mode> AT+CRC=[<mode>] <mode>: 0: disable extended format 1: enable extended format [27.007] 6.11 When enabled, an incoming call is indicated with +CRING: <type> with, <type> : FAX or VOICE or ASYNC Note d étude / Technical document : URD / Edition 05

41 page 41/ MOBILE EQUIPMENT CONTROL AND STATUS COMMANDS CACM Command : Accumulated call meter (ACM) reset or query AT+CACM Accumulated call meter (ACM) reset or query AT+CACM=? AT+CACM? +CACM: <acm> (current acm value) AT+CACM=<password> (reset the value) [27.007] 8.25 <password> : SIM PIN2 This AT command needs SIM and network where AOC are allowed. Note d étude / Technical document : URD / Edition 05

42 page 42/ CAMM Command : Accumulated call meter maximum (ACM max) set or query AT+CAMM Accumulated call meter maximum (ACM max) set or query AT+CAMM=? AT+CAMM? +CAMM: <acmmax> write command AT+CAMM= [<acmmax>[,<passwd>]] +CAMM: <acmmax> <acmmax>: <passwd>: string type; three bytes of the max ACM value in hexadecimal format 0 disables ACMmax feature SIM PIN2 [27.007] 8.26 This AT command needs SIM and network where AOC are allowed. Note d étude / Technical document : URD / Edition 05

43 page 43/ CCWE Command : Call Meter maximum event AT+CCWE Call Meter maximum event AT+CCWE=? +CCWE: (list of supported <mode>s) AT+CCWE? +CCWE: <mode> AT+CCWE=<mode> Parameter <mode>: 0: Disable the call meter warning event 1: Enable the call meter warning event [27.007] 8.28 When enabled, a notification (+CCWV) is sent shortly (approx. 30s) before the ACM max is reached. This AT command needs SIM and network where AOC are allowed. Note d étude / Technical document : URD / Edition 05

44 page 44/ CALA Command : Set alarm time AT+CALA Set alarm time AT+CALA=? +CALA: (list of supported <n>s),(list of supported <type>s) AT+CALA? [+CALA: <time>,<n1>,[<recurr>] [<CR><LF>+CALA: <time>,<n2>,[<recurr>] AT+CALA=<time>[,<n>[, <recurr>]] =<time> <time>: <n>: <recurr>: internal clock (Cf. +CCLK) string type "hh:mm:ss" if <recurr> is present or "yy/mm/dd,hh:mm:ss" if not. index of the alarm (range 1 to 5 for now). string type value indicating day of week for the alarm in one of the following formats: "<1..7>[,<1..7>[ ]]" Sets a recurrent alarm for one or more days in the week. The digits 1 to 7 corresponds to the days in the week, Monday (1),, Sunday (7). "0" Sets a recurrent alarm for all days in the week. Note d étude / Technical document : URD / Edition 05

45 page 45/237 [27.007] 8.16 To set up a recurrent alarm for one or more days in the week, the <recurr>parameter may be used. When an alarm is timed out and executed, the unsolicited result code +CALV: <n> is returned. When woken up by an alarm, the module is fully started. It is the responsibility of the host to turn it off and to set a new alarm if recurrent alarms are not used. Only for not recurrent alarm : if date and hour are over, +CME ERROR: 4 is returned After CPOF command, +CALV: correctly received if autobaud speed is not selected. Examples - at+cala= 07/04/11,11:34:25 -> set a one shot alarm saved at index 1 for the specified date and time - at+cala= 07/04/11,11:34:00,3 -> set a one shot alarm saved at index 3 for the specified date and time - at+cala= 11:50:45,1, 1,4 -> set a recurrent alarm saved at index 1 for every monday and thursday at 11:50:45 noonwhen woken up by an alarm, the module is fully started. It is the responsibility of the host to turn it off anew. Note d étude / Technical document : URD / Edition 05

46 page 46/ CALD Command : Delete alarm AT+CALD Delete alarm AT+CALD=? +CALD: (list of supported <n>s) AT+CALD=<n> <n>: index of the alarm [27.007] 8.38 Action command deletes an alarm in the MT Note d étude / Technical document : URD / Edition 05

47 page 47/ CCLK Command : Real time clock AT+CCLK Real time clock AT+CCLK=? AT+CCLK? +CCLK: <time> AT+CCLK=<time> Parameter <time>: string type value; format is "yy/mm/dd,hh:mm:ss+/-timezone", where characters indicate year (last two digits), month, day, hour, minutes, seconds; [27.007] 8.15 Timezone data may be sent in the string but is handled and reported only by XS200 module CPOF Command : Power off AT+CPOF Power off AT+CPOF=? Execute command AT+CPOF +CPOF: () Power off the Module Note d étude / Technical document : URD / Edition 05

48 page 48/ CIND Command : Indicator control AT+CIND Indicator control AT+CIND=? +CIND: ("battchg",(0..5)),("signal",(0..5)),("service",(0,1)),("call",(0,1)),("smsfull",(0...2)) AT+CIND? +CIND: <battchg>,<signal>,<service>,<call>, <smsfull> <battchg>: battery charge level (0-5) <signal>: signal quality (0-5) <service>: service availability (0-1) <call>: call in progress (0-1) <smsfull>: SMS memory storage (0-2) 0: Memory available 1: Memory full 2 SMS has been rejected [27.007] 8.9 <smsfull> indication not available on all products Note d étude / Technical document : URD / Edition 05

49 page 49/ SIM notification : Hardware detection +SIM Notification Notification +SIM: <status> <status>: INSERTED or EXTRACTED When the SIM card is extracted, the SIMCD signal is reset by the sim socket. - all SIM signals are reset ( VCC, IO, RST, CLK). - a notification is sent to the COM1, - the module makes a network detachment, - after 2s, the module makes a reboot. When the SIM card is inserted, the SIMCD signal is set by the sim socket. - a notification is sent to the COM1, - after 2s, the module makes a reboot. This feature is not enabled with standard parameters, contact SAGEM for more information.

50 page 50/ CLAC Command : List all available AT commands AT+CLAC List all available AT commands AT+CLAC=? +CLAC: (list of supported <type>s) AT+CLAC=<type> List of command of the selected <type> only <AT Command1>[<CR> <LF> <AT Command2>[ ]] Execute command AT+CLAC List of all supported AT Commands <AT Command1> [<CR> <LF> <AT Command2>[ ]] <type>: type of commands "&" : + : \ : : "*" : [27.007] 8.37 This command provides the AT Command list available for the user

51 page 51/ CMEC Command : Mobile Equipment control mode AT+CMEC Mobile Equipment control mode AT+CMEC=? +CMEC: (list of supported <keyp>s),(list of supported <disp>s),(list of supported <ind>s) AT+CMEC? +CMEC: <keyp>,<disp>,<ind> AT+CMEC=[<keyp>[,<d isp>[,<ind>]]] <keyp>: keypad management not significant for MO110d and MO190 and XS200 (no keypad) <disp>: display management not significant for MO110d and MO190 and XS200 (no display) <ind>: 0: only ME can set the status of its indicators (command +CIND can only be used to read the indicators) [27.007] 8.6 Set command selects the equipment, which operates ME keypad, writes to ME display and sets ME indicators CDIS Command : Display Control This command is listed in the command supported, but as there is no display on the MO110d, MO190, MO200 and XS200 products, this command must not be used CKPD Command : Keypad Control This command is listed in the command supported, but as there is no display on the MO XXX and XS X00 products, this command must not be used CFUN Command : Set Phone Functionality This command has been implemented for SAGEM S.A.. It allows to power on the module and not to start the communication task. Use AT+CFUN=1 to start the SIM detection, then communication.

52 CMER Command : Mobile Equipment event reporting page 52/237 AT+CMER Mobile Equipment event reporting AT+CMER=? AT+CMER? AT+CMER=[<mode>[,< keyp>[,<disp>[,<ind>[, <bfr>]]]]] [27.007] CMER: (list of supported <mode>s),(list of supported <keyp>s),(list of supported <disp>s),(list of supported <ind>s),(list of supported <bfr>s) +CMER: <mode>,<keyp>,<disp>,<ind>,<bfr> <mode>: 0: buffer unsolicited result codes in the TA; if TA result code buffer is full, codes can be buffered in some other place or the oldest ones can be discarded. 1: discard unsolicited result codes when TA-TE link is reserved (e.g. in on-line data mode); otherwise forward them directly to the TE 2: buffer unsolicited result codes in the TA when TA-TE link is reserved (e.g. in on-line data mode) and flush them to the TE after reservation; otherwise forward them directly to the TE <keyp>: 0: no keypad event reporting 1: keypad event reporting using result code +CKEV: <key>,<press>. <key> indicates the key (refer IRA values defined in table in subclause "Keypad control +CKPD") and <press> if the key is pressed or released (1 for pressing and 0 for releasing). Only those key pressings, which are not caused by +CKPD shall be indicated by the TA to the TE. 2: keypad event reporting using result code +CKEV: <key>,<press>. All key pressings shall be directed from TA to TE. <disp>: 0: no display event reporting <ind>: 0: no indicator event reporting 1: indicator event reporting using result code +CIEV: <ind>,<value>. <ind> indicates the indicator order number (as specified for +CIND) and <value> is the new value of indicator. Only those indicator events, which are not caused by +CIND shall be indicated by the TA to the TE <bfr>: 0: TA buffer of unsolicited result codes defined within this command is cleared when <mode> is entered 1: TA buffer of unsolicited result codes defined within this command is flushed to the TE when <mode> is entered ( response shall be given before flushing the codes) Example: AT+CMER=? +CMER: (0,1,2),(0,1,2),(0),(0,1),(0,1) AT+CMER? +CMER: 0,0,0,0,0 AT+CMER=0,2;+CMER? +CMER: 0,2,0,0,0

AT COMMAND SET HILO/HILONC MODULES. ~ Freedom of speech for smart machines ~

AT COMMAND SET HILO/HILONC MODULES. ~ Freedom of speech for smart machines ~ AT COMMAND SET HILO/HILONC MODULES ~ Freedom of speech for smart machines ~ page 2/339 FICHE RECAPITULATIVE / REVISION HISTORY E d Date Date Référence 1 jj/mm/aaaa URD1 OTL 5635.1 008 / 70248 2 20/09/2007

More information

OnCell G2150I AT Command Set

OnCell G2150I AT Command Set OnCell G2150I AT Set First Edition, March 2007 www.moxa.com/product Moxa Technologies Co., Ltd. Tel: +886-2-8919-1230 Fax: +886-2-8919-1231 Web: www.moxa.com MOXA Technical Support Worldwide: support@moxa.com

More information

LTE AT commands for Test automation

LTE AT commands for Test automation LTE AT commands for Test automation Device Requirements Issued: Feb-14 This document provides initial information related to the Verizon Wireless Long Term Evolution (LTE) Supplementary Signaling Conformance

More information

NOKIA GSM CONNECTIVITY TERMINAL AT COMMAND GUIDE

NOKIA GSM CONNECTIVITY TERMINAL AT COMMAND GUIDE NOKIA GSM CONNECTIVITY TERMINAL AT COMMAND GUIDE Copyright Nokia 2002-2003. All rights reserved. Issue 3.0 Contents 1. INTRODUCTION...2 2. DATA CONNECTIONS...3 3. AT COMMAND SYNTAX...4 3.1 REGISTER COMMANDS...4

More information

AT Commands Reference for Motorola OS Handsets MOTOROLA OS 3G-GSM

AT Commands Reference for Motorola OS Handsets MOTOROLA OS 3G-GSM AT Commands Reference for Motorola OS Handsets MOTOROLA OS 3G-GSM Copyright 2009, Motorola, Inc. All rights reserved. This documentation may be printed and copied solely for use in developing products

More information

AT COMMANDS SUPPORTED BY SAGEM myx-5 MOBILE PHONES

AT COMMANDS SUPPORTED BY SAGEM myx-5 MOBILE PHONES AT COMMANDS SUPPORTED BY SAGEM myx-5 MOBILE PHONES Copyright Notification No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction

More information

Serial interface configuration. Syntax of the standard AT commands

Serial interface configuration. Syntax of the standard AT commands Serial interface configuration The serial interface on the ATEUS GSM Gateway has to be initialized as follows: 19200,8,N,1 (baud rate 19200, data bits: 8, parity: no, stop bit: 1) No automatic baud rate

More information

Ai-Thinker Inc A6_A7_A6C_A20 模组 AT 命令集 V1.03. Contents

Ai-Thinker Inc A6_A7_A6C_A20 模组 AT 命令集 V1.03. Contents Contents CONTENTS 2 1 INTRODUCTION 6 1.1 PURPOSE 6 1.2 DOCUMENT CONVENTIONS 6 1.3 REFERENCES 7 1.4 CHARACTER SET 8 1.5 AT COMMAND SYNTAX. 8 2 GENERAL COMMANDS. 11 2.1 AT. 11 2.2 AT+CPOF SWITCH OFF MOBILE

More information

CDMA DATA TERMINAL AT Command Set Application Information. December.19, 2007

CDMA DATA TERMINAL AT Command Set Application Information. December.19, 2007 CDMA DATA TERMINAL AT Command Set Application Information December.19, 2007 About this Guide CDMA (Code Division Multiple Access) Data Module operating functions are implemented as AT commands, and are

More information

AT COMMAND SET PRODUCTS RANGE. HILO/HILO NC /HiAll NC /HILO3G/ HILO NC -3GPS. ~ Freedom of speech for smart machines ~

AT COMMAND SET PRODUCTS RANGE. HILO/HILO NC /HiAll NC /HILO3G/ HILO NC -3GPS. ~ Freedom of speech for smart machines ~ AT COMMAND SET HILO/HILO NC /HiAll NC /HILO3G/ HILO NC -3GPS PRODUCTS RANGE ~ Freedom of speech for smart machines ~ FICHE RECAPITULATIVE / REVISION HISTORY Ed Date Référence Date 1 jj/mm/aaaa URD1 OTL

More information

ADH8066 Quad band GSM/GPRS Module

ADH8066 Quad band GSM/GPRS Module ADH8066 Quad band GSM/GPRS Module AT Reference Manual ADH Technology Co.,LTD Subject to changes in technology, design and availability URL: http://www.adh-tech.com.tw Revision History Version Date

More information

ETSI TS V7.7.0 ( )

ETSI TS V7.7.0 ( ) TS 100 916 V7.7.0 (2001-12) Technical Specification Digital cellular telecommunications system (Phase 2+); AT command set for GSM Mobile Equipment (ME) (3GPP TS 07.07 version 7.7.0 Release 1998) GLOBAL

More information

AT Commands Set SIM340DZ_ATC_V1.00

AT Commands Set SIM340DZ_ATC_V1.00 AT Commands Set SIM340DZ_ATC_V1.00 Document Title: SIM340DZ AT Commands Set Version: 1.00 Date: 2008-06-03 Status: Document Control ID: Release SIM340DZ_ATC_V1.00 General s SIMCOM offers this information

More information

GM862-GPS Software User Guide GM862-GPS Software User Guide 1vv Rev. 4-24/01/07

GM862-GPS Software User Guide GM862-GPS Software User Guide 1vv Rev. 4-24/01/07 GM862-GPS Software User Guide Contents: GM862-GPS Software User Guide 1 Overview...4 2 Basic Operations...5 2.1 Command Syntax...5 2.1.1 Interface Style...5 2.2 Command Response Timeout...6 2.3 Turning

More information

ETSI TS V7.5.0 ( )

ETSI TS V7.5.0 ( ) TS 100 916 V7.5.0 (1999-12) Technical Specification Digital cellular telecommunications system (Phase 2+); AT command set for GSM Mobile Equipment (ME) (GSM 07.07 version 7.5.0 Release 1998) GLOBAL SYSTEM

More information

Telit EZ10-PCS/-GPRS/-GSM Product Description

Telit EZ10-PCS/-GPRS/-GSM Product Description Telit EZ10-PCS EZ10-GPRS EZ10-GSM Wireless Modem Product Description DAI Telecom S.p.a. 2004 Reproduction forbidden without DAI Telecom written authorization All Right reserved Right of modification reserved

More information

SIM300D AT Command Set SOFTWARE SPECIFICATION

SIM300D AT Command Set SOFTWARE SPECIFICATION SOFTWARE SPECIFICATION Document Name: SIM300D AT Commands Set Version: 01.00 Date: 2006-3-27 DocId: SIM300D_ATC_V1.00 Status: Release General s Simcom offers this information as a service to its customers,

More information

ETSI TS V1.1.1 ( )

ETSI TS V1.1.1 ( ) TS 103 368 V1.1.1 (2016-11) TECHNICAL SPECIFICATION Railway Telecommunications; Commands necessary for mobile radio equipment operation on railways 2 TS 103 368 V1.1.1 (2016-11) Reference DTS/RT-0039 Keywords

More information

Command Descriptions. AT Commands. Chapter 3 AT Command Interface

Command Descriptions. AT Commands. Chapter 3 AT Command Interface Command Descriptions AT Commands The following sections provide detailed descriptions about the commands that the GSM Data Module supports. +++ AT Escape Command When the GSM Data Module has established

More information

TS V6.2.0 ( )

TS V6.2.0 ( ) Technical Specification Digital cellular telecommunications system (Phase 2+); AT command set for GSM Mobile Equipment (ME) (GSM 07.07 version 6.2.0 Release 1997) GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS

More information

RIM OEM Radio Modem for GSM/ GPRS Wireless Networks RIM 1902G and RIM 1802G

RIM OEM Radio Modem for GSM/ GPRS Wireless Networks RIM 1902G and RIM 1802G RIM OEM Radio Modem for GSM/ GPRS Wireless Networks RIM 1902G and RIM 1802G AT Command Reference Guide Version 1.2 RIM OEM Radio Modem for GSM/GPRS Wireless Networks AT Command Reference Guide Version

More information

Data sheet: AI Thinker GSM GPRS Module A6C Camera Module. AI Thinker GSM GPRS Camera Module A6C

Data sheet: AI Thinker GSM GPRS Module A6C Camera Module. AI Thinker GSM GPRS Camera Module A6C AI Thinker GSM GPRS Camera Module A6C page 2 of 217 Technical Informations: 7 Features: 7 Dimensions: 8 Board Pinout: 9 Board Pinout: 10 Basic Setup AT Mode 11 AT Command Overview 12 Convention 12 Syntax

More information

AT Commands Set SIM600_ATC_V1.01

AT Commands Set SIM600_ATC_V1.01 AT Commands Set SIM600_ATC_V1.01 Document Title: SIM600 AT Commands Set Version: 1.01 Date: 2006-11-13 Status: Document Control ID: Release SIM600_ATC_V1.01 General s Simcom offers this information as

More information

3.5G AT Commands Manual v1.0

3.5G AT Commands Manual v1.0 3.5G AT s Manual v1.0 History Company was established on 15th of April 1998. Main residence is based in Vilnius. Company started with production of telecommunication devices. In 2001 company expanded its

More information

EUROPEAN pr ETS TELECOMMUNICATION July 1999 STANDARD

EUROPEAN pr ETS TELECOMMUNICATION July 1999 STANDARD DRAFT EUROPEAN pr ETS 300 916 TELECOMMUNICATION July 1999 STANDARD Eighth Edition Source: SMG Reference: RE/SMG-040707QR7 ICS: 33.020 Key words: Digital cellular telecommunications system, Global System

More information

SIM700D AT Command Set SIM700D_ATC_V1.00

SIM700D AT Command Set SIM700D_ATC_V1.00 SIM700D AT Command Set Document Title: SIM700D AT Commands Set Version: 1.00 Date: 2008-3-18 Status: Document Control ID: General s Simcom offers this information as a service to its customers, to support

More information

WCDMA UGxx AT Commands Manual

WCDMA UGxx AT Commands Manual WCDMA UGxx AT Commands Manual UMTS/HSPA Module Series Rev. WCDMA_UGxx_AT_Commands_Manual_V1.4 Date: 2015-05-21 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For

More information

ISU AT Command Reference NEXT ASSY USED ON REV DESCRIPTION DATE APPROVED IRIDIUM HANDSET. XA Engineering control release of ver /25/01 T.

ISU AT Command Reference NEXT ASSY USED ON REV DESCRIPTION DATE APPROVED IRIDIUM HANDSET. XA Engineering control release of ver /25/01 T. APPLICATION REVISION HISTORY NEXT ASSY USED ON REV DESCRIPTION DATE APPROVED IRIDIUM HANDSET XA Engineering control release of ver. 1.3 9/25/01 T. Michl XB Engineering control release of ver. 1.4 2/22/02

More information

WCDMA UGxx AT Commands Manual

WCDMA UGxx AT Commands Manual WCDMA UGxx AT Commands Manual UMTS/HSPA Module Series Rev. WCDMA_UGxx_AT_Commands_Manual_V1.5 Date: 2015-08-18 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For

More information

Monarch Platform LR AT Commands Reference Manual

Monarch Platform LR AT Commands Reference Manual 4G-EZ Software Suite Monarch Platform LR5.1.1.0 AT Commands Reference Manual 15-55 Boulevard Charles de Gaulle 92700 Colombes, France Phone. +33.1.70.72.16.00 Fax. +33.1.70.72.16.09 www.sequans.com contact@sequans.com

More information

EC25&EC21 AT Commands Manual

EC25&EC21 AT Commands Manual EC25&EC21 AT Commands Manual LTE Module Series Rev. EC25&EC21_AT_Commands_Manual_V1.0 Date: 2016-05-30 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

UC15 AT Commands Manual

UC15 AT Commands Manual UC15 AT Commands Manual UMTS/HSPA Module Series Rev. UC15_AT_Commands_Manual_V1.0 Date: 2013-12-12 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

Iridium Model 9500 and 9505 AT Command Compliance

Iridium Model 9500 and 9505 AT Command Compliance TABLE OF CONTENTS 1 PURPOSE... 2 2 APPLICABILITY... 2 3 VERIFICATION... 2 4 COMPLIA NCE... 3 4.1 COMMAND/RESPONSE RELATED AT COMMANDS...3 4.2 CONFIGURATION/CONTROL RELATED AT COMMANDS...3 4.3 DATA COMPRESSION

More information

Manual Reference. Modem Commands. S35i, C35i, M35i

Manual Reference. Modem Commands. S35i, C35i, M35i Manual Modem s for the SIEMENS Mobile Phone S35i, C35i, M35i page 1 of 7 The command descriptions or example sequences in this document imply no liability or warranty in any way. The author therefore will

More information

UC20 AT Commands Manual

UC20 AT Commands Manual UC20 AT Commands Manual UMTS/HSPA Module Series Rev. UC20_AT_Commands_Manual_V1.2 Date: 2014-02-20 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

EC20 AT Commands Manual

EC20 AT Commands Manual EC20 AT Commands Manual LTE Module Series Rev. EC20_AT_Commands_Manual_V1.1 Date: 2015-07-14 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance, please

More information

BG96 AT Commands Manual

BG96 AT Commands Manual BG96 AT Commands Manual LTE Module Series Rev. BG96_AT_Commands_Manual_V2.0 Date: 2017-08-11 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance, please

More information

GIVE W INGS TO YOUR IDEAS

GIVE W INGS TO YOUR IDEAS GIVE W INGS TO YOUR IDEAS AT s Interface Guide Revision: 004 Date: June 2004 PLUG IN TO THE WIRELESS WORLD AT s Interface Guide for AT x41 Revision : 004 Date : Reference : WM_ASW_OAT_UGD_010 confidential

More information

ATWin (Shanghai) Ltd. AT Commands for AT137/139 Rev1.0

ATWin (Shanghai) Ltd. AT Commands for AT137/139 Rev1.0 Document Name: AT137/139 AT commands Manual Version: 01.00 Date: 2010-11-18 Doc ID: Status: Release Copy right This document contains proprietary infmation of ATWin. Copying disclosing it to the third

More information

M22 / M23 / M23G AT Command User Guide

M22 / M23 / M23G AT Command User Guide M22 / M23 / M23G AT User Guide Version: 1.7.7 Date: 20/09/2006 2006 BenQ Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system

More information

Document Title Version: 1.00 Date: Status: General Notes SIMCom offers this information as a service to its customers, to support applicati

Document Title Version: 1.00 Date: Status: General Notes SIMCom offers this information as a service to its customers, to support applicati Document Title Version: 1.00 Date: 2016-08-22 Status: General Notes SIMCom offers this information as a service to its customers, to support application and engineering efforts that use the products designed

More information

AT Command Set Siemens Cellular Engines

AT Command Set Siemens Cellular Engines Siemens Cellular Engines TC35 Module TC37 Module TC35 Terminal Version: 02.10 DocID: TC35-ATC-01-V02.10 Document Name: AT Command Set Siemens Cellular Engines Version: 02.10 Date: 23.05.2001 Technical

More information

UC20 AT Commands Manual

UC20 AT Commands Manual UC20 AT Commands Manual UMTS/HSPA Module Series Rev. UC20_AT_Commands_Manual_V1.5 Date: 2014-09-26 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

Siemens Cellular Engines. TC35 Module TC37 Module TC35 Terminal. Version: DocID: TC3X_ATC_01_V03.10

Siemens Cellular Engines. TC35 Module TC37 Module TC35 Terminal. Version: DocID: TC3X_ATC_01_V03.10 Siemens Cellular Engines TC35 Module TC37 Module TC35 Terminal Version: 03.10 DocID: TC3X_ATC_01_V03.10 Document Name: AT Command Set Siemens Cellular Engines Version: 03.10 Date: 11.01.2002 Doc Id: TC3X_ATC_01_V03.10

More information

AT commands APLICATION NOTE

AT commands APLICATION NOTE AT commands APLICATION NOTE SYMBOLS USED Symbols used Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible problems, which

More information

SIM7020 Series_AT Command Manual_V1.00 SIMCOM COMFIDENTIAL FILE

SIM7020 Series_AT Command Manual_V1.00 SIMCOM COMFIDENTIAL FILE SIM7020 Series_AT Command Manual_V1.00 Document Title SIM7020 Series AT Command Manual Version 1.00 Date 20180410 Status Document Control ID General s Release SIM7020 Series_AT Command Manual_V1.00 SIMCom

More information

Manual Reference. AT Command Set (GSM 07.07, GSM 07.05) S25

Manual Reference. AT Command Set (GSM 07.07, GSM 07.05) S25 Manual Reference AT Command Set (GSM 07.07, GSM 07.05) for SIEMENS Mobile Phone S25 and Derivatives 17.08.99 page 1 of 31 All rights reserved. No part of this work covered by the copyrights hereof may

More information

AT Command Interface Specification

AT Command Interface Specification Issue 01 Date 2013-04-10 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters.

More information

Telit GM862-QUAD/QUAD-PY. Software User Guide. Telit Communications S.p.a vv , Rev. ISSUE#0-27/09/2005

Telit GM862-QUAD/QUAD-PY. Software User Guide. Telit Communications S.p.a vv , Rev. ISSUE#0-27/09/2005 Telit GM862-QUAD GM862-QUAD-PY Software User Guide Telit Communications S.p.a. 2003 Reproduction forbidden without Telit Communications written authorization All Right reserved Page 1 of 128 Contents 1

More information

ETSI TS V3.7.0 ( )

ETSI TS V3.7.0 ( ) Technical Specification Digital cellular telecommunications system (Phase 2+) (GSM); Universal Mobile Telecommunications System (UMTS); AT command set for User Equipment (UE) () GLOBAL SYSTEM FOR MOBILE

More information

H20 AT Command User Guide

H20 AT Command User Guide H20 AT User Guide Version: 1.0.8 Date: 2008/12/24 Author: Cariel Huang 2008 Qisda Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval

More information

AT Commands Reference Guide For LM ST10791A r

AT Commands Reference Guide For LM ST10791A r AT Commands Reference Guide For LM940 20 APPLICABILITY TABLE PRODUCT LM940 SW Version Generic:24.01.511 Verizon:24.01.521 AT&T:24.01.541 EU:24.01.551 AU:24.01.561 Reproduction forbidden without Telit Wireless

More information

GC864-QUAD / PY SW USER GUIDE GC864-QUAD / PY Software User Guide 1vv Rev. 1-05/02/07

GC864-QUAD / PY SW USER GUIDE GC864-QUAD / PY Software User Guide 1vv Rev. 1-05/02/07 GC864-QUAD / PY SW USER GUIDE GC864-QUAD / PY Software User Guide This document is relating to the following products: GC864-QUAD 3990250675 GC864-PY 3990250676 Reproduction forbidden without Telit Communications

More information

SIM800C-DS_Application Note _V1.00

SIM800C-DS_Application Note _V1.00 SIM800C-DS_Application Note _V1.00 Document Title: SIM800C-DS Application Note Version: 1.00 Date: Status: Document Control ID: Release SIM800C-DS_Application Note_V1.00 General Notes SIMCom offers this

More information

GSM Dual Band Modem. AT Command Manual. Edition 4.00

GSM Dual Band Modem. AT Command Manual. Edition 4.00 GSM Dual Band Modem AT Manual Edition 4.00 November 2010 CONTENTS 1 INTRODUCTION... 6 1.1 SCOPE OF THIS DOCUMENT... 6 1.2 RELATED DOCUMENTS... 6 1.3 ETSI SECRETARIAT... 6 1.4 DEFINITIONS... 6 2 AT COMMANDS

More information

AT Commands User Manual Table of Contents Introduction... 7 AT commands features... 7 General behaviors... 8 General commands... 9

AT Commands User Manual Table of Contents Introduction... 7 AT commands features... 7 General behaviors... 8 General commands... 9 Manual Table of Contents U 1 Introduction... 7 1.1 Purpose of the document...7 1.2 Terms and Abbreviations...7 2 AT commands features... 7 2.1 Serial interface settings...7 2.2 Command line...7 2.3 Default

More information

AT Commands Specification. Ericsson G3x Fixed Wireless Terminal

AT Commands Specification. Ericsson G3x Fixed Wireless Terminal AT Commands Specification Ericsson G3x Fixed Wireless Terminal Page 2 of 46 TABLE OF CONTENTS 1. INTRODUCTION 5 1.1 Purpose...5 2. AT command List 6 3. AT command 13 3.1 FWT Proprietary Commands...13 3.1.1

More information

3GPP TS V6.3.0 ( )

3GPP TS V6.3.0 ( ) Technical Specification 3rd Generation Partnership Project; Technical Specification Group Terminals; AT command set for User Equipment (UE) (Release 6) GLOBAL SYSTEM FOR MOBILE COMMUNICATIONS R The present

More information

ATCOMMANDS INTERFACEGUIDE

ATCOMMANDS INTERFACEGUIDE ATCOMMANDS INTERFACEGUIDE For Firmware version 5.34 and above Date: November 2002 This page is intentionally left blank Contents 1 Introduction... 12 1.1 Scope of this document...12 1.2 Related documents...12

More information

AT Command Set SIM5350 _ATC_V1.02

AT Command Set SIM5350 _ATC_V1.02 AT Command Set SIM5350 _ATC_V1.02 Document Title: SIM5350 AT Command Set Version: 1.02 Date: 2014-06-09 Status: Document ID: Release SIM5350_ATC_V1.02 General Notes SIMCom offers this information as a

More information

AT Command Interface Specification

AT Command Interface Specification Issue 02 Date 2013-06-18 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters.

More information

M10. Quectel Cellular Engine. AT Commands Set M10_ATC_V1.01

M10. Quectel Cellular Engine. AT Commands Set M10_ATC_V1.01 M10 Cellular Engine AT Commands Set Document Title: M10 AT Commands Set Revision: 1.01 Date: 2009-06-26 Status: Document Control ID: Release General s offers this information as a service to its customers,

More information

Application Note. SIM7100_SMS_Application_Note_V

Application Note. SIM7100_SMS_Application_Note_V SIM7100 Application Note SMS 0 SIM7100_SMS_Application_Note_V0.01 2014-11-8 Document Title: SIM7100 SMS Application Note Version: 0.01 Date: 2015-02-10 Status: Document ID: Release SIM7100_SMS_Application_Note_V0.01

More information

AT Command Interface Specification

AT Command Interface Specification V100R001 Issue 02 Date 2014-09-25 Copyright Huawei Technologies Co., Ltd. 2014. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means without prior written

More information

GGB-1916 GNSS/2.5G GSM/GPRS/Bluetooth Module AT Commands Manual 2016 LOCOSYS Technology Inc.

GGB-1916 GNSS/2.5G GSM/GPRS/Bluetooth Module AT Commands Manual 2016 LOCOSYS Technology Inc. www.locosystech.com GGB-1916 GNSS/2.5G GSM/GPRS/Bluetooth Module AT Commands Manual 2016 LOCOSYS Technology Inc. Document history Version Date Updates 0.1 Aug 5, 2016 Creation 0.2 Oct 21, 2016 Modify some

More information

SYNOPSIS PROJECT TITLE : GSM BASED E-NOTICE BOARD

SYNOPSIS PROJECT TITLE : GSM BASED E-NOTICE BOARD SYNOPSIS PROJECT TITLE : GSM BASED E-NOTICE BOARD OBJECTIVE: The main aim of this project will be to design a SMS driven automatic display board which can replace the currently used programmable electronic

More information

AT Commands Reference Guide

AT Commands Reference Guide AT Commands Reference Guide For LM960 19 APPLICABILITY TABLE PRODUCT LM960 SW Version Generic:32.00.010-xxxx Verizon:32.01.020-xxxx Sprint:32.00.030-xxxx AT&T:32.00.040-xxxx Reproduction forbidden without

More information

Telit Communications S.p.A.

Telit Communications S.p.A. Telit GM862-PCS GM862-PYTHON GM862-QUAD GM862-QUAD-PY TRIZIUM TRIZIUM-GPS GE863-QUAD GE863-PY Telit Communications S.p.A. Reproduction forbidden without Telit Communications S.p.A. written authorization

More information

MC35 Module MC35 Terminal

MC35 Module MC35 Terminal Siemens Cellular Engines MC35 Module MC35 Terminal Version: 02.00 DocID: MC35_ATC_01_V02.00 Document Name: AT Command Set Siemens Cellular Engines Version: 02.00 Date: 11.01.2002 Doc Id: MC35_ATC_01_V02.00

More information

M35 AT Commands Manual

M35 AT Commands Manual M35 AT Commands Manual GSM/GPRS Module Series Rev. M35_AT_Commands_Manual_V1.0 Date: 2013-07-11 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

AT Command Interface Specification

AT Command Interface Specification Issue 02 Date 2013-12-24 Huawei Technologies Co., Ltd. provides customers with comprehensive technical support and service. For any assistance, please contact our local office or company headquarters.

More information

AT Commands Set SIM300_ATC_V1.06

AT Commands Set SIM300_ATC_V1.06 AT Commands Set SIM300_ATC_V1.06 Document Title: SIM300 AT Commands Set Version: 1.06 Date: 2006-12-04 Status: Document Control ID: Release SIM300_ATC_V1.06 General s Simcom offers this information as

More information

AT Commands Set SIM300D_ATC_V2.00

AT Commands Set SIM300D_ATC_V2.00 AT Commands Set SIM300D_ATC_V2.00 Document Title: SIM300D AT Commands Set Version: 2.00 Date: 2007-07-31 Status: Document Control ID: Release SIM300D_ATC_V2.00 General s Simcom offers this information

More information

GSM/GPRS Data Module Product Design. AT Commands Manual

GSM/GPRS Data Module Product Design. AT Commands Manual GSM/GPRS Data Module Product Design AT Commands Manual TABLE OF CONTENTS 1. Introduction... 7 1.1 Purpose of the document... 7 1.2 Terms and Abbreviations... 7 2 AT commands features... 9 2.1 Serial interface

More information

M66 AT Commands Manual

M66 AT Commands Manual M66 AT Commands Manual GSM/GPRS Module Series Rev. M66_AT_Commands_Manual_V1.0 Date: 2014-08-15 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

UniMod GSM-3. Operation Manual

UniMod GSM-3. Operation Manual Bär Industrie-Elektronik GmbH Rathsbergstraße 23 D-90411 Nürnberg Germany Phone +49 911 970590 Fax +49 911 9705950 Internet: www.baer-gmbh.com Page 2 of 12 Contents Page 1. Requirements... 3 2. Safety

More information

M12. Quectel Cellular Engine. AT Commands Manual. M12_AT_Commands_Manual_V3.2

M12. Quectel Cellular Engine. AT Commands Manual. M12_AT_Commands_Manual_V3.2 M12 Cellular Engine AT Commands Manual M12_AT_Commands_Manual_V3.2 Document Title M12 AT Commands Manual Version 3.2 Date 2012-05-31 Status Document Control ID Released M12_AT_Commands_Manual_V3.2 General

More information

UniModSet / MetcomTSet Parameterization Software

UniModSet / MetcomTSet Parameterization Software Parameterization Software User Manual E170812217067 Bär Industrie-Elektronik GmbH Siemensstr. 3 D-90766 Fürth Phone: +49 (0)911 970590 Fax: +49 (0)911 9705950 Internet: www.baer-gmbh.com COPYRIGHT Copyright

More information

M95 AT Commands Manual

M95 AT Commands Manual M95 AT Commands Manual GSM/GPRS Module Series Rev. M95_AT_Commands_Manual_V3.1 Date: 2014-09-16 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

ISU AT Command Reference

ISU AT Command Reference Version 2.32 ISU AT Command Reference Iridium Proprietary May 19, 2009 i Iridium Proprietary ISU AT Command Reference Revision History Revision History Version Date Author Reason 1.0 06-Jul-99 Motorola

More information

ETSI TS V8.5.0 ( ) Technical Specification

ETSI TS V8.5.0 ( ) Technical Specification TS 127 007 V8.5.0 (2008-10) Technical Specification Digital cellular telecommunications system (Phase 2+); Universal Mobile Telecommunications System (UMTS); AT command set for User Equipment (UE) (3GPP

More information

Canal+ Compatibility

Canal+ Compatibility Canal+ Compatibility Application Note The is a V.22bis (and lower speed) single chip data modem intended to be integrated in any device that requires transferring data over the PSTN (Public Switched Telephone

More information

Application Note basic Voice and SMS Connection with SIM900 rev03

Application Note basic Voice and SMS Connection with SIM900 rev03 Connection with rev03 S MUST BE Connection with rev03 AT ATI ATE0 AT+GMR AT+GMI AT+GMM AT+GSN AT+CSCA? AT+CNUM? AT+CREG? AT+CSQ AT+GCAP AT+CMEE=2 AT&W AT&V AT&F AT+CPBS="ON" NETWORK CENTRE NUMBERS NETWORK

More information

APPLICATION NOTE. Using the SUTRON RADAR LEVEL CONTROLLER (RLR ) with a MULTIMODEM GPRS (Wireless Modem MTCBA-G-F4)

APPLICATION NOTE. Using the SUTRON RADAR LEVEL CONTROLLER (RLR ) with a MULTIMODEM GPRS (Wireless Modem MTCBA-G-F4) 1 Using the SUTRON RADAR LEVEL CONTROLLER (RLR-0002-1) with a MULTIMODEM GPRS November 2008 Prepared by: Integrated Systems Division November 2008 2 TABLE OF CONTENTS PRODUCT OVERVIEW...3 SUTRON RADAR

More information

MC60 AT Commands Manual

MC60 AT Commands Manual MC60 AT Commands Manual GSM/GPRS/GNSS Module Series Rev. MC60_AT_Commands_Manual_V1.1 Date: 2016-08-17 www.quectel.com Our aim is to provide customers with timely and comprehensive service. For any assistance,

More information

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount)

Low Speed Modems for Dial and Leased Circuits 2400E (Standalone) 2400R (Rackmount) Low Speed Modems for Dial and Leased Circuits 2400E-030-4 (Standalone) 2400R-030-4 (Rackmount) QUALITY COMMUNICATIONS PRODUCTS Made in the U.S.A. 11-1010-002 INTRODUCTION The Data Connect ST2400E-2 and

More information

User Module. AT Modem Emulator APPLICATION NOTE

User Module. AT Modem Emulator APPLICATION NOTE User Module AT Modem Emulator APPLICATION NOTE USED SYMBOLS Used symbols Danger important notice, which may have an influence on the user s safety or the function of the device. Attention notice on possible

More information

/ AT Command Manual for Firmware L30. AirPrime WS6318

/ AT Command Manual for Firmware L30. AirPrime WS6318 WWW.INFOPULSAS.LT / info@infopulsas.lt AT Command Manual for Firmware L30 AirPrime WS6318 4111702 5.0 April 12, 2012 Important Notice Due to the nature of wireless communications, transmission and reception

More information

4.3 Ingenico Telium OS modem specific commands

4.3 Ingenico Telium OS modem specific commands 4.3 Ingenico Telium OS modem specific commands 4.3.1 Command: return to command mode Syntax : void esc_command (void) 4.4 AT Commands The AT commands are used to: C operational parameters, Establish a

More information

ON THE USE OF AT COMMANDS FOR CONTROLING THE MOBILE PHONE WITH MICROCONTROLLER LABORATORY EXERCISE

ON THE USE OF AT COMMANDS FOR CONTROLING THE MOBILE PHONE WITH MICROCONTROLLER LABORATORY EXERCISE 2007 Poznańskie Warsztaty Telekomunikacyjne Poznań 6-7 grudnia 2007 P OZNAN POZNAN UNIVERSIT UNIVERSITY Y OF OF TECHNOLOGY ACADEMIC ACADEMIC JOURNALS JOURNALS No 54 Electrical Engineering 2007 Adrian KLIKS*

More information

GPRS G2 Modems. AT Commands Reference Guide

GPRS G2 Modems. AT Commands Reference Guide GPRS G2 Modems AT s Reference Guide Copyright and Technical Support GPRS AT s for Multi-Tech G2 Cellular Modems Reference Guide This Set Applies to the Following Products: SocketModem Cell MTSMC-G2 SocketModem

More information

User s Manual CDMA Cellular Model CDM819s Serial Modem CDMA Cellular Model CDM819u USB Modem

User s Manual CDMA Cellular Model CDM819s Serial Modem CDMA Cellular Model CDM819u USB Modem User s Manual CDMA Cellular Model CDM819s Serial Modem CDMA Cellular Model CDM819u USB Modem For use with LF1.2.04 and LF1.2.06 modules In Support Of Hardware Revision1.0 and 2.0 Revision 1.8 April 2005

More information

MM-6854 / MM-6864 GSM Dual-Band Data Modem

MM-6854 / MM-6864 GSM Dual-Band Data Modem MM-6854 / MM-6864 GSM Dual-Band Data Modem MM-6854 MM-6864 Application Notes For more information or general enquiries, please call; R. F. Solutions Ltd., Unit 21, Cliffe Industrial Estate, South Street,

More information

Cinterion BGS2T (RS232) Terminal Starter Kit. Getting Started Guide

Cinterion BGS2T (RS232) Terminal Starter Kit. Getting Started Guide Cinterion BGS2T (RS232) Terminal Starter Kit Getting Started Guide BGS2T (RS232) Terminal Starter Kit Contents PLEASE NOTE KIT CONTENTS MAY VARY ACCORDING TO ORIGIN AND THE INTENDED COUNTRY OF OPERATION

More information

ETSI TC SMG#24 Tdoc SMG Madrid, Spain December 1997

ETSI TC SMG#24 Tdoc SMG Madrid, Spain December 1997 ETSI TC SMG#24 Tdoc SMG3 97-922 Madrid, Spain 15-19 December 1997 Source: SMG4 Agenda item: 5.5 Title: Change Requests on GSM 07.05, 07.07 and on Workitem V.120/RDI interworking The attached CRs are correction

More information

TP560i. TP560i 56Kbps Data/Fax/Voice Modem Chip Set PCI Bus Interface. User s Manual AT Command Set

TP560i. TP560i 56Kbps Data/Fax/Voice Modem Chip Set PCI Bus Interface. User s Manual AT Command Set TP560i 56Kbps Data/Fax/Voice Modem Chip Set PCI Bus Interface User s Manual AT Command Set Introduction This is a high performance ITU-V.90 56Kbps modem; Computer can make connection with remote terminal,

More information

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem

ZM56 High-Speed Industrial Modem. Command Summary. 1 ZM56 High-Speed Industrial Modem ZM56 High-Speed Industrial Modem Command Summary 1 ZM56 High-Speed Industrial Modem AT Command Summary Command AT ATA ATDT ATE0 ATE1 ATH ATH1 ATI ATO ATS Description Attention Prefix Precedes all commands

More information

AT Command Interface Specification

AT Command Interface Specification EM770W UMTS M2M Wireless Module V100R001 Issue 18 Date 2009-28-07 Distributed by HUAWEI TECHNOLOGIES CO., LTD Maxon Electronics Australia Pty. Ltd. is proud to distribute the Huawei HSUPA Mini PCI Module

More information

This document is the sole and exclusive property of Maxon. Not to be distributed or divulged without prior written agreement.

This document is the sole and exclusive property of Maxon. Not to be distributed or divulged without prior written agreement. H S D PA S ta n d a r d AT C o m m a n d s M a n u a l VERSION 1.2 This document is the sole and exclusive property of Maxon. Not to be distributed or divulged without prior written agreement. 36A Gibson

More information

EC2x&EG9x&EM05 PPP Application Note

EC2x&EG9x&EM05 PPP Application Note EC2x&EG9x&EM05 PPP Application Note LTE Module Series Rev. EC2x&EG9x&EM05_PPP_Application_Note_V1.0 Date: 2017-12-08 Status: Released www.quectel.com Our aim is to provide customers with timely and comprehensive