DC Compute SAN. Carlos Lopez CCIE SAN, DC #21063 David Kester CCIE SAN #19555 Ed Mazurek CCIE SNA/IP, SAN #6448
|
|
- Silvia Holt
- 5 years ago
- Views:
Transcription
1 DC Compute SAN Carlos Lopez CCIE SAN, DC #21063 David Kester CCIE SAN #19555 Ed Mazurek CCIE SNA/IP, SAN #6448
2 Introductions Carlos Lopez CCIE SAN, DC #21063 Technical Leader TAC David Kester CCIE SAN #19555 Team Leader Storage Networking Ed Mazurek CCIE SNA/IP, SAN #6448 Technical Leader TAC 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 2
3 Agenda Components Topology Nexus FC NPV vs FCoE-NPV Bugs MDS Slow Drain Troubleshooting Enhancements
4 Components
5 Cisco Multi-Protocol Product Portfolio: SAN, LAN, and Compute LAN/SAN SAN 16G COMPUTE Cisco Nexus 7000 Cisco Nexus 9000 Cisco MDS x16G Line-Rate FC 48x10GE Line-Rate FCoE Cisco UCS 6300 Series FI Cisco UCS 6200 Series FI Cisco Nexus 5500 Nexus 5672UP-16G Cisco Nexus 5600 Cisco MDS 9396S Cisco MDS 9148S Cisco MDS 9718 Cisco Nexus G FC: Nexus 2348UPQ Cisco Nexus x40GE Line-Rate FCoE Cisco MDS 9250i 12+ Years of Proven NX-OS Operating System Cisco Prime Data Center Network Manager (DCNM) Cisco UCS B-Series Blade Servers Cisco UCS C-Series Rack Servers Consistent, Simplified Features, Management, and Programmability 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
6 Cisco MDS 9000 Series 16G FC Director Switches Cisco 48x10G Line-rate FCoE Module Cisco 48x16G Line-rate FC Module Future Proof Reliable Multi-Protocol Flexibility Investment Protection Ease of Management Cisco MDS 9718 Director Cisco MDS 9710 Director Cisco MDS 9706 Director Cisco 24x40G FCoE Line-rate FCoE Module Driving Innovations for the Next Decade with a complete 16G Portfolio Deploy Small, Medium, Large SANs with Cisco MDS 9000 Family 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
7 Cisco MDS 9000 Series 16G FC Fabric Switches Cisco MDS 9250i 16G Multi-Service Fabric Switch Cisco MDS 9396S 16G FC Fabric Switch Cisco MDS 9148S 16G FC Fabric Switch Pay-as-You-Grow Enterprise Class Features Reliability Multi-Protocol Flexibility Ease of Management Driving Innovations for the Next Decade with a complete 16G Portfolio Deploy Small, Medium, Large SANs with Cisco MDS 9000 Family 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
8 Cisco MDS 9700 Directors Comparison 26 RU Winning Points 32G FC line-rate ready Interchangeable line cards Redundant hardware Common PSUs, Linecards Single OS, Management Better UCS Interoperability 9 RU 14 RU Hardware Feature MDS 9706 MDS 9710 MDS 9718 Line Card slots Line rate 16Gbps FC or 10 Gbps FCoE Line rate 40 Gbps FCoE Fabric Module slots (available / default) 6 / 3 6 / 3 6 / 6 Sup Slots Fabric Module location Rear Rear Rear Airflow Front to Back Front to Back Front to Back Power Supply slots Power Consumption (Typical/Max) 2425W / 2620W 4615W / 5020W 4742/8462W 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
9 Converged FEX Architecture Enabling Director-class resiliency at Converged Access Multi-Protocol Storage and Host Connectivity: FC, FCoE and IP Converged Architecture includes Cisco Data center portfolio: SAN(MDS 9700), LAN(Nexus 2k-7k) and Compute (UCS Chassis) accessibility 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
10 MDS 9250i Multiservice Fabric Switch Multi-Protocol Support Features 16G FC, 10GE FCoE, 1GE/10GE FCIP, iscsi Intelligent Storage Services for FC and FCoE SANs Fiber Channel over IP (FCIP) IO Accelerator (IOA) Data Mobility Migration (DMM) Integrated Management via Data Center Network Manager (DCNM) FICON Certified Benefits Single Platform for deploying Storage Services across FC, FCoE and IP based Storage Area Networks (SANs) High-Bandwidth SAN Extension across MAN/WAN Vendor independent array migration tools Interoperate data between FC and FCoE arrays 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
11 MDS 9250i Overview Next Generation Multiservice Intelligent Services-oriented Fabric Switch Provides FCIP, IOA and DMM Integrated 40x16G FC, 8x10GE FCoE, and 2x1GE/10GE FCIP/iSCSI ports Enclosure: 2 RU; Redundant and hot-swappable power supplies and fan trays Console USB Mgmt Cisco and/or its affiliates. All rights reserved. Cisco Public
12 Cisco MDS 9148S Fabric Switch Front Back 1 RU 48 x 16G FC Line Rate Performance 12- to 48-ports in 12-port increments Dual Power Supplies and Fans for Enterprise-Class Availability VERSATILE EASY TO USE ENTERPRISE-CLASS Line-rate 16/8/4/2G FC Ports Industry-leading port range Start with 12-port base Scale up with 12-port license Or, full 48-port option available Automated Provisioning Quick Configuration Wizard Same OS and Management across Industry s broadest SAN Portfolio Non-disruptive software upgrades Up to 32 Virtual SANs (VSANs) Inter-VSAN Routing (IVR), QOS, PortChannels, N-Port ID Virtualization (NPIV), N-Port Virtualization (NPV), Comprehensive Security Hardware-based slow-drain detection and recovery High-Performance, Easy to Deploy, Enterprise-class Fabric Switch 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
13 Introducing MDS 9396S 96-Port 16G Fabric Switch 2 RU Cisco MDS 9396S Versatile Easy to Use Enterprise-Class Start with 48-port base; Scale up with 12-port license Or full 96-port option available Automated provisioning Quick Configuration Wizard Same OS and management across industry s broadest SAN portfolio Dual-power supplies and fans, non-disruptive software upgrades Up to 4095 B2B credits per port (MDS 9396S); up to 253 B2B credits per port (MDS 9148S) Up to 32 Virtual SAN (VSANs) Hardware-based slow-drain detection and recovery, Inter-VSAN routing, QoS, PortChannels, N-Port ID Virtualization (NPIV), N-Port Virtualization (NPV) Forward Error Correction, Link Encryption (FC TrustSec) Industry s Most Affordable 16G Fabric Switch Family 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
14 MDS 9396S B2B credits All ports in a port group can have maximum of 500 B2B credits Enterprise license enables extended credits that means up to 4095 B2B credit per port in a port group Port group can have maximum of 4150 B2B credits. Best Practice: Avoid grouping all E ports in same port group/ioslice Generic Formula: For every 1 KM distance with 1GB speed, we need.5 BB credit for standard FC frame (2112 bytes). CLI command: show port-resources module Cisco and/or its affiliates. All rights reserved. Cisco Public
15 Topologies UCS-FI N5K MDS
16 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
17 Separation makes sure that the design is highly available even when one of the fabrics goes down Cisco and/or its affiliates. All rights reserved. Cisco Public
18 Redundant redundancy is not required 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
19 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
20 Working with TAC Topology Commands Use the show topology command to display the interswitch links `show topology` FC Topology for VSAN 1 : Interface Peer Domain Peer Interface Peer IP Address(Switch Name) port-channel 6 0x62(98) port-channel (sw201a) Cisco and/or its affiliates. All rights reserved. Cisco Public
21 Working with TAC Topology Commands Use the show fcs ie command to display all the switches in the VSAN Core# show fcs ie IE List for VSAN: IE-WWN IE Mgmt-Id Mgmt-Addr (Switch-name) :01:00:0d:ec:39:19:c1 S(Rem) 0xfffc0e (sw204a) 20:01:00:0d:ec:39:1a:01 S(Rem) 0xfffc (sw202a) 20:01:00:0d:ec:fb:88:41 S(Loc) 0xfffc (sw200a) 20:01:00:2a:6a:8c:0b:01 S(Adj) 0xfffc (sw201a) Loc = Local = this switch Adj = Adjacent = connected switch 21 Rem = Remote = more than one hop away 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public
22 Working with TAC Topology Commands Use the show fcns database npv command to find Cisco NPV switches. Core# show fcns database npv VSAN NPV NODE-NAME :20:01:00:0d:ec:51:06:01 NPV IP_ADDR : NPV INTERFACE :port-channel 30 CORE SWITCH WWN :20:00:00:0d:ec:24:ef:c0 CORE INTERFACE :Po Cisco and/or its affiliates. All rights reserved. Cisco Public
23 Working with TAC Topology Commands Use the show npv flogi-table command to shows where the device is attached and it s uplink. NPV# show npv flogi-table SERVER EXTERNAL INTERFACE VSAN FCID PORT NAME NODE NAME INTERFACE fc1/ x0d :00:00:00:c9:71:04:4e 20:00:00:00:c9:71:04:4e Po Cisco and/or its affiliates. All rights reserved. Cisco Public
24 Working with TAC Topology Commands Note: Ensure both links are connected to the same upstream IP address. This tells you which upstream switch the UCS FI is connected to in case you need to connect to upstream switch to verify the connectivity. NPV# show npv internal info external-interface all grep addr: fabric mgmt addr: fabric mgmt addr: Cisco and/or its affiliates. All rights reserved. Cisco Public
25 Nexus FC NPV vs FCoE-NPV
26 Nexus FC NPV vs FCoE-NPV FC and NPV FCoE-NPV FC or FCoE FC or FCoE Nexus or MDS NPIV Nexus or MDS NPIV FC or FCoE FCoE FCoE Only FCoE FC N5K NPV Both FC and FCoE FCoE N5K FCoE-NPV 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 26
27 Nexus FC NPV vs FCoE-NPV Enabling FC and NPV FC or FCoE First Enable FCoE and then NPV N5K(config)# feature fcoe FC license checked out successfully fc_plugin extracted successfully FC plugin loaded successfully FCoE manager enabled successfully FC enabled on all modules successfully Nexus or MDS NPIV FC or FCoE N5K(config)# feature npv Verify that boot variables are set and the changes are saved. Changing to npv mode erases the current configuration and reboots the switch in npv mode. Do you want to continue? (y/n):y FCoE FC N5K NPV Also enable fcoe qos 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 27
28 Nexus FC NPV vs FCoE-NPV Enabling FC and NPV Actually, after enabling fcoe, then NPV, What really happens N5K(config)# feature npv Verify that boot variables are set and the changes are saved. Changing to npv mode erases the current configuration and reboots the switch in npv mode. Do you want to continue? (y/n):y When the switch is reloaded in the NPV mode, Some configuration is saved: switchname management ip configuration and vrf boot variable username / password details ntp configuration callhome configuration snmp-server details feature fcoe FCoE FC or FCoE FC Nexus or MDS NPIV FC or FCoE N5K NPV 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 28
29 Nexus FC NPV vs FCoE-NPV Enabling FCoE-NPV Enable fcoe-npv FC or FCoE n5k(config)# feature fcoe-npv FCoE NPV license checked out successfully fc_plugin extracted successfully FC plugin loaded successfully FCoE manager enabled successfully FCoE NPV enabled on all modules successfully No reload No reconfiguration fcoe qos still required FCoE Nexus or MDS NPIV FCoE N5K FCoE-NPV 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 29
30 Nexus FC NPV vs FCoE-NPV Comparison FC NPV FCoE-NPV Protocols FC and/or FCoE FCoE License FC_FEATURES_PKG FCOE_NPV_PKG Command feature fcoe feature npv feature fcoe-npv Write Erase Reload feature npv no Nexus Models N5K, N6K N5K, N6K, N9K FCoE QoS Required Required Disable FKA on Core for ISSU No if uplink is FC yes 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 30
31 Nested NPV Can I connect two NPV Switches? After enabling NPV, NPIV can also be enabled Connecting two Cisco NPV switches is not supported Cisco NPIV Cisco NPIV FC or FCoE Cisco NPV+NPIV FC or FCoE Cisco NPV+NPIV Cisco NPV 3 rd Party Vendor Unsupported Supported 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 32
32 Bugs
33 Frequent Bugs CSCun Weak CBC mode and weak ciphers should be disabled in SSH server Symptom: SSH servers on Cisco Nexus devices may be flagged by security scanners due to the inclusion of SSH ciphers and HMAC algorithms that are considered to be weak. These may be identified as 'SSH Server CBC Mode Ciphers Enabled' and 'SSH Server weak MAC Algorithms Enabled' or similar. Conditions: This issue applies to Cisco Nexus 7000, Cisco Nexus 5000 and MDS 9000 series switches. SSH functionality is enabled by default in Cisco NX-OS. The current SSH server status is displayed using the show ssh server command Cisco and/or its affiliates. All rights reserved. Cisco Public 34
34 Frequent Bugs CSCun Weak CBC mode and weak ciphers should be disabled in SSH server With the Fix: If an SSH client configured to use weak ciphers is used to log in to a Cisco device with this fix, the login may fail. The following messages are logged in the switch syslog: %DAEMON-2-SYSTEM_MSG: fatal: no matching cipher found: client 3descbc,blowfish-cbc server aes128-ctr,aes192-ctr,aes256-ctr - sshd Reconfigure any SSH clients not to use weak ciphers like 3des-cbc or blowfishcbc. DCNM uses SSH to manage Cisco devices and must be upgraded to at least 7.2(1) to work with devices with this fix. Known-fixed-releases: 7.3(0)N1(1) 7.2(1)N1(1) 7.2(0)N1(1) 6.2(11c) 5.2(8g) 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 35
35 Frequent Bugs CSCue SNMP crashes on SNMP bulk get query Symptom: The SNMP process may crash with the following messages displayed in the output of show logging log %KERN-2-SYSTEM_MSG: mts_is_q_space_available_new():1416:total mtsbuf size for sap 28, exceeds limit 15 perc of kernel %KERN-2-SYSTEM_MSG: mts_acquire_q_space() failing - no space in sap 28, uuid 26 send_opc 3176, pid 3616, proc_name sctpt_rx_thr - kernel %KERN-2-SYSTEM_MSG: [sap 28][pid 4406][comm:snmpd] sap recovering failed and so Killed - kernel %SYSMGR-2-SERVICE_CRASHED: Service "snmpd" (PID 4406) hasn't caught signal 6 (core will be saved) 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 36
36 Frequent Bugs CSCue SNMP crashes on SNMP bulk get query Conditions: This bug affects both Nexus and MDS switches. It has been observed when a monitoring device is using snmp-bulk-get requests on the entity- MIB for multiple FEX modules at one time, or if there is continuous polling from multiple polling stations on slow mibs. Some examples of mibs that may be affected by continuous snmp bulk walk are: qos mib entity mib entity-fru mib bridge mib 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 37
37 Frequent Bugs CSCue SNMP crashes on SNMP bulk get query Workaround: A possible workaround is configuring the no snmp-server counter cache enable command. This command prevents SNMP bulk gets from getting cached via the use of MTS buffers. This will prevent the MTS buffers from getting consumed and resulting in a process crash. The result of the command is that the interface table might be slower to update the statistics (since caching is disabled). Note: This workaround is only available on Nexus 7000 switches. This defect is fixed in NX-OS releases 5.2.9, (Nexus 7000), 5.2.8g (MDS), and (Nexus 7000 and MDS), 6.0(2)N1(2a) (Nexus 5K and 6k) Further Problem Description: A possible way of verifying if you are affected by this bug is to issue the command show system internal mts buffers summary and check if notifications for sap 28 are increasing Cisco and/or its affiliates. All rights reserved. Cisco Public 38
38 Frequent Bugs CSCus MDS 9700 show tech detail missing some commands Symptom: MDS 9710 and MDS 9706 show tech detail missing some commands, like 'show running-config' and 'show startup-config'. Conditions: MDS 9710 and MDS 9706 at NX-OS 6.2(11). Workaround: Collect show tech-support all along with show tech-support detail Fixed in NX-OS 6.2(11c) and above Cisco and/or its affiliates. All rights reserved. Cisco Public 39
39 Frequent Nexus 5K/6K Bugs CSCuj Unified fc interfaces come up as Ethernet after disruptive upgrades Symptom: In Cisco Nexus 5000 series switches, a disruptive upgrade with reason incompatible image causes the Unified Ports configured as FC ports to come up as Ethernet ports after upgrade. However, the FC port configuration still exists in the running configuration. Conditions: Upgrade between any two incompatible images and the fc interfaces are unified interfaces requiring the slot and port commands, slot z port x - y mode fc Backup the configuration before upgrading 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 40
40 Frequent Nexus 5K/6K Bugs CSCuj Unified fc interfaces come up as Ethernet after disruptive upgrades Proactive Workaround: Do ISSU only between compatible images. Please check the result of install command for image compatibility. Reactive Workaround: After the disruptive ISSU between incompatible images, do the following: a. copy startup-config bootflash: b. copy running-config startup-config c. reload After reload: d. copy bootflash: running-config e. copy running-config startup-config Now the device should have the same configurations as before upgrade. Consult Release Notes for non-disruptive upgrade path 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 41
41 Frequent Nexus 5K/6K Bugs CSCup FC interfaces are not listed in IF-MIB snmp Symptom: FC interfaces are not listed in IF-MIB snmp walk. Device Manager is not working correctly with the Nexus 5548UP or 5596UP (GEM modules installed) when the expansion module ports are set to fibre channel mode. Hovering over the ports with the mouse in Device Manager will display for example, "Ethernet 1/17 Status: failed". Looking at the same ports via CLI will show that the ports are really in FC mode and not configured as Ethernet ports Cisco and/or its affiliates. All rights reserved. Cisco Public 42
42 Frequent Nexus 5K/6K Bugs CSCup FC interfaces are not listed in IF-MIB snmp Conditions: Nexus 5548UP or Nexus 5596UP running NX-OS 7.0(2)N1(1) with GEM Expansion module ports configured to operate in Fibre Channel mode Some ports are in Fibre Channel mode on the base chassis. More Info: NX-OS 7.0(1)N1(1) and all previous software versions are not affected by this defect. This is an NX-OS bug, not a Device Manager bug. Fixed in 7.0(6)N1 and above Cisco and/or its affiliates. All rights reserved. Cisco Public 43
43 Nexus 5K/6K Bug CSCur10558 Trunk Protocol Enable does not show in running config when disabled Resolution Summary: 1 Made the command [no] trunk protocol enable hidden 2. Added appropriate warning message when the command is run on CLI Fixed in 7.3(0)N1(1) 7.2(1)N1(1) 7.1(3)N1(1) 7.0(7)N1(1) 6.2(9) (config-if)# no trunk protocol Warning: This will globally disable the switch's ability to form any trunks and impacts existing trunk ports Do you wish to continue(y/n)? [n] 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 44
44 Nexus 5K/6K Bug CSCur10558 Trunk Protocol Enable does not show in running config when disabled [no] trunk protocol is not in the running config.. or the show tech detail. Tip: show tech will contain show port internal info all You should always have... Epp state: Enabled Port Trunking Protocol (PTP) and Port Channel Protocol (PCP) use the EPP frame. No practical reason to disable fibre channel trunking Cisco and/or its affiliates. All rights reserved. Cisco Public 45
45 Cisco MDS NX-OS 7.3(0)D1(1) OUI Enhancement Example: Adding OUIs Switch(config)# wwn oui 0x10001c OUI - A 24 bit globally unique number assigned by IEEE. Port-channel functionality includes Cisco OUI check of peer switch Cisco and/or its affiliates. All rights reserved. Cisco Public 46
46 MDS Slow Drain Troubleshooting Enhancements
47 MDS Slow Drain Troubleshooting Enhancements NX-OS 6.2(9) and 6.2(13) added several enhancements system timeout no-credit-drop triggered at exact time by HW TxWait slowport-monitor New port-monitor counters txwait tx-slowport-oper-delay tx-slowport-count show tech-support slowdrain DCNM Slow Drain Analysis TAC tool MDS_show_tech_slowdrain_analysis For a more comprehensive information see: - SAN Congestion! Understanding, Troubleshooting, Mitigating in a Cisco Fabric (2016 Las Vegas) Cisco and/or its affiliates. All rights reserved. Cisco Public 48
48 system timeout no-credit-drop Triggered by HW at exact time no-credit-drop causes frames to be dropped immediately if the destination port is at 0 Tx credits for the time specified system timeout no-credit-drop 200 mode f Previously no-credit-drop was triggered by SW process at 100ms intervals NX-OS 6.2(9) and later triggered by the HW at exact time the threshold is reached Should be used in conjunction with lowering congestion-drop threshold Recommended for F ports Can drastically improve ISL performance under slow drain conditions xxx_force_timeout_on/off counter By default no-credit-drop is not enabled 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 49
49 TxWait enhancements txwait txwait is a counter that increments every 2.5us when port is at 0 Tx credits and there are frames queued for transmit txwait * 2.5 / = seconds of time the port was unable to transmit Only applies to the following: MDS 9500 with generation 4 linecards: MDS 9000 Family 32-Port 8-Gbps Advanced Fibre Channel Switching Module (DS-X K9) MDS 9000 Family 48-Port 8-Gbps Advanced Fibre Channel Switching Module (DS-X K9) MDS Port 16-Gbps Fibre Channel Switching Module (DS-X K9) MDS 9148S 16G Multilayer Fabric Switch MDS 9250i Multiservice Fabric Switch MDS 9396S 16G Multilayer Fabric Switch Others will return zero 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 50
50 TxWait enhancements - continued txwait can be seen in the following: show interface counters Raw value in 2.5us units show interface counters Percentage Tx credits are available for last 1s/1m/1h/72h show process creditmon txwait-history 60sec, 60min, 72hour graphs show logging onboard txwait SNMP fciftxwaitcount variable 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 51
51 TxWait enhancements - continued txwait - show interface counters mds9710-1# show interface fc1/13 counters i fc wait fc1/ us Txwaits due to lack of transmit credits * 2.5 / = seconds Cumulative since the interface counters were last cleared The above indicates the MDS was not able to transmit for over 15 seconds since the counters were last cleared 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 52
52 TxWait enhancements - continued txwait - Percentage Tx credits are available for last 1s/1m/1h/72h Utilizes the underlying txwait counter MDS9710-1# show interface fc1/13 counters fc1/13 5 Transmit B2B credit transitions to zero 2 Receive B2B credit transitions to zero us TxWait due to lack of transmit credits Percentage Tx credits not available for last 1s/1m/1h/72h: 1%/5%/3%/2% 32 receive B2B credit remaining 128 transmit B2B credit remaining 128 low priority transmit B2B credit remaining 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 53
53 Level 1: Latency - Troubleshooting txwait - show logging onboard txwait MDS9513# show logging onboard txwait module Module: 4 txwait count Notes: - Sampling period is 20 seconds - Only txwait delta >= 100 ms are logged Recorded every 20 seconds only when >= 100ms Interface Delta TxWait Time Congestion Timestamp 2.5us ticks seconds fc4/ % Wed May 27 13:20: fc4/ % Wed May 27 13:19: fc4/ % Wed May 27 13:19: fc4/ % Wed May 27 13:19: Delta values recorded when they are more than 100ms in the 20 second interval 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 54
54 Level 1: Latency - Troubleshooting txwait-history Graphical display of time where Tx credits are not available Similar in format to cpu history 3 graphs per port Last 60 seconds Last 60 minutes Last 72 hours Utilizes the underlying txwait counter mds9710-1# show process creditmon txwait-history module 1 port 13 TxWait history for port fc1/13: ============================== # ## 900 # ## 800 ## ## 700 ## ## 600 ### ### 500 ### ## ### 400 ### ## #### 300 ### ## #### 200 ### ## #### 100 ### ## #### Credit Not Available per second (last 60 seconds) # = TxWait (ms) 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 55
55 Level 1: Latency - Troubleshooting slowport-monitor system timeout slowport-monitor <1-500> mode e f Must be configured! Events are captured every 100ms Last 10 events per port captured in slowport-monitor-events Logging onboard slowport-monitor-events captures more events Currently implemented for: Gen 3 LCs - DS-X K9 and DS-X92xx-96K9 modules Gen 4 LCs - DS-X K9 and DS-X K9 modules 9700 & 9396S (Gen 5) 9250i & 9148S Differences exist between Gen3, Gen4 and 9700/9250i/9148S/9396S 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 56
56 Level 1: Latency - Troubleshooting slowport-monitor 9700/9250i/9148S/9396S (Gen 5 LCs) Gen5/9250i/9148S/9396S have enhanced HW capabilities Each 100ms interval the number of times Tx credits remained at 0 for the configured(admin) delay is counted. The average operational delay is determined This is how long the port was at 0 Tx credits Recorded when at least one complete event occurred More events available via logging onboard slowport-monitor-events MDS9710-1# show process creditmon slowport-monitor-events Module: 01 Slowport Detected: YES ========================================================================= Interface = fc1/ admin slowport oper Actual Timestamp average delay delay detection delay (ms) count (ms) /01/15 23:03: /01/15 23:03: /01/15 23:03: /01/15 23:03: Configured delay(5ms) 4 events in last 100ms Note: Oper delay limited by nocredit-drop threshold 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 57
57 Slow Drain Alerting and Mitigation Port-monitor alerting Port-monitor allows monitoring of several counters relating to slow drain credit-loss-reco Credit loss recovery counter lr-rx The number of link resets received by the fc-port lr-tx Link resets transmitted by the fc-port timeout-discards Timeout discards counter New in 6.2(13) tx-credit-not-available Credit not available counter(in 100ms increments) tx-discards Tx discards counter tx-slowport-count Number of slowport events tx-slowport-oper-delay Slowport operational delay txwait Amount of time at 0 Tx credits and packets queued rx-datarate Rx data rate as a percentage of link speed tx-datarate Tx data rate as a percentage of link speed Note: There are other counters that are valuable and should also be considered for inclusion in monitoring but are not part of slow drain 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 58
58 Troubleshooting Documentation for TAC show tech-support slowdrain Contains all the commands available that pertain to slow drain Contains context commands to understand the FC topology Contains name server commands to identify devices Contains active zonesets to understand device relationships Most useful when run from DCNM and gathered for the entire fabric SAN Client -> Tools -> Run CLI Commands When opening up a case with the TAC please have this available! Used for MDS_show_tech_slowdrain_analysis 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 59
59 DCNM Slow Drain Analysis DCNM 7.1(1) added Slow Drain Analysis DCNM 7.2(2) added improvements DCNM 10.0(1) added improvements Used for pulling fabric wide slow drain counters for a defined period of time Useful for ongoing slow drain problems Accessed from the Web Client Health -> Diagnostics -> Slow drain Analysis 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 60
60 MDS_show_tech_slowdrain_analysis Red indicates level 3 (creditloss) Slow draining end device! Yellow indicates level 1 (latency) Arrows indicate direction of congestion Orange indicates level 2 (timeout drops) Green indicates no congestion 2016 Cisco and/or its affiliates. All rights reserved. Cisco Public 61
61 Thank you
Congestion Avoidance. Finding Feature Information
This chapter provides information about slow devices that cause congestion (slow-drain devices) in a network and how to avoid slow-drain devices. Finding Feature Information, page 1 Feature History for,
More informationConfiguring FCoE NPV. Information About FCoE NPV. This chapter contains the following sections:
This chapter contains the following sections: Information About FCoE NPV, page 1 FCoE NPV Model, page 3 Mapping Requirements, page 4 Port Requirements, page 5 NPV Features, page 5 vpc Topologies, page
More informationCisco MDS NX-OS Release 6.2Configuration Limits 2
Cisco MDS NX-OS Release 6.2 Configuration Limits Cisco MDS NX-OS Release 6.2Configuration Limits 2 Switch Level Fibre Channel Configuration Limits for Cisco MDS 9000 Series Switches 2 Fabric Level Fibre
More informationLarge SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors
White Paper Large SAN Design Best Practices Using Cisco MDS 9700 and MDS 9500 Multilayer Directors What You Will Learn As SANs continue to grow in size, many factors need to be considered to help scale
More informationFibre Channel Slow Drain Device Detection and Congestion Avoidance- An Overview
Fibre Channel Slow Drain Device Detection and Congestion Avoidance- An Overview All data traffic between end devices in the SAN fabric is carried by Fibre Channel Class 3, and in some cases, Class 2 services,
More informationConfiguring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces
Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces This chapter provides details about configuring native fiber channels on Cisco Nexus 2348UPQ FEX, and contains the following sections:
More informationMonitoring and Alerting in Cisco MDS Fabric
Monitoring and Alerting in Cisco MDS Fabric 2016 Cisco and/or its affiliates. All rights reserved. 1 Contents About This Document 3 Supported Hardware and Software 3 Introduction 4 Cisco Prime Data Center
More informationCisco MDS 9000 Series Switches
Cisco MDS 9000 Series Switches Overview of Cisco Storage Networking Solutions Cisco MDS 9000 Series 32-Gbps Directors Cisco MDS 9718 Cisco MDS 9710 Cisco MDS 9706 Configuration Chassis, dual Supervisor-1E
More informationQuick Reference Guide
Connectrix MDS Quick Reference Guide An Overview of Cisco Storage Solutions for EMC In collaboration with: 1 2016 Cisco and/or its affiliates. All rights reserved. Connectrix MDS Directors EMC Model MDS-9706
More informationCisco MDS 9000 Series Switches
Cisco MDS 9000 Series Switches Overview of Cisco Storage Networking Solutions Cisco MDS 9000 Series Directors Cisco MDS 9718 Cisco MDS 9710 Cisco MDS 9706 Configuration Chassis, dual Supervisor-1E Module,
More informationMDS 9000 and Nexus FC/FCoE TAC Time. David Kester CCIE SAN #19555 Carlos Lopez CCIE SAN, CCIE DC #21063
MDS 9000 and Nexus FC/FCoE TAC Time David Kester CCIE SAN #19555 Carlos Lopez CCIE SAN, CCIE DC #21063 Introductions David Kester CCIE SAN #19555 Team Leader Storage Networking Carlos Lopez CCIE SAN, CCIE
More informationNexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example
Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example Document ID: 116248 Contributed by Jim Hicks and Shelley Bhalla, Cisco TAC Engineers. May 01, 2014 Contents Introduction Prerequisites
More informationCisco MDS 9250i Multiservice Fabric Switch Overview. Introduction CHAPTER
CHAPTER 1 Cisco MDS 9250i Multiservice Fabric Switch Overview This chapter describes the Cisco MDS 9250i Multiservice Fabric Switch and includes these topics: Introduction, page 1-1 Chassis Description,
More informationCisco MDS 9000 Family Blade Switch Solutions Guide
. Solutions Guide Cisco MDS 9000 Family Blade Switch Solutions Guide Introduction This document provides design and configuration guidance for administrators implementing large-scale blade server deployments
More informationConfiguring FCoE NPV. FCoE NPV Overview. FCoE NPV Benefits
FCoE NPV Overview This chapter describes how to configure Fiber Channel over Ethernet (FCoE) N-port Virtulization (NPV) on Cisco NX-OS devices. FCoE NPV Overview, on page 1 VNP Ports, on page 3 Licensing
More informationDesigning SAN Using Cisco MDS 9000 Series Fabric Switches
White Paper Designing SAN Using Cisco MDS 9000 Series Fabric Switches September 2016 2016 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public. Page 1 of 15 Contents What You
More informationConfiguring Fibre Channel Interfaces
This chapter contains the following sections:, page 1 Information About Fibre Channel Interfaces Licensing Requirements for Fibre Channel On Cisco Nexus 3000 Series switches, Fibre Channel capability is
More informationF port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example
F port channel trunk from MDS 9148 (NPV) to MDS 9509 (NPIV) Configuration Example Document ID: 117781 Contributed by Edward Mazurek, Cisco TAC Engineer. Sep 05, 2014 Contents Introduction Prerequisites
More information"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary
Description Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary v6.0 is a five-day instructor-led course that is designed to help students prepare for the Cisco CCNP Data Center
More informationQuestion: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?
Volume: 327 Questions Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects? A. primary first, and then secondary
More informationCisco I/O Accelerator Deployment Guide
Cisco I/O Accelerator Deployment Guide Introduction This document provides design and configuration guidance for deploying the Cisco MDS 9000 Family I/O Accelerator (IOA) feature, which significantly improves
More informationAdministration and monitoring of the Cisco Data Center with Cisco DCNM
Administration and monitoring of the Cisco Data Center with Cisco DCNM Paul Dunon Consulting SE Network Management Emeric Calabrese Consulting SE Data Center Agenda DCNM Solution overview Best Practices
More informationStorage Access Network Design Using the Cisco MDS 9124 Multilayer Fabric Switch
Storage Access Network Design Using the Cisco MDS 9124 Multilayer Fabric Switch Executive Summary Commercial customers are experiencing rapid storage growth which is primarily being fuelled by E- Mail,
More informationConfiguring PortChannels
This chapter provides information about PortChannels and how to configure the PortChannels. Finding Feature Information, page 1 Information About PortChannels, page 1 Prerequisites for PortChannels, page
More informationCisco Nexus 7000 Switches Supervisor Module
Data Sheet Cisco Nexus 7000 Switches Supervisor Module Data Sheet The Cisco Nexus 7000 Switches Supervisor Module (Figure 1) scales the control plane and data plane services for the Cisco Nexus 7000 Switches
More informationP Commands. Cisco MDS 9000 Series Command Reference 1
P s passive-mode, page 3 password strength-check, page 4 pathtrace, page 6 peer (DMM job configuration submode), page 11 peer-info ipaddr, page 12 periodic-inventory notification, page 14 permit (IPv6-ACL
More informationVblock Architecture. Andrew Smallridge DC Technology Solutions Architect
Vblock Architecture Andrew Smallridge DC Technology Solutions Architect asmallri@cisco.com Vblock Design Governance It s an architecture! Requirements: Pretested Fully Integrated Ready to Go Ready to Grow
More informationFibre Channel Performance: Congestion, Slow Drain, and Over Utilization, Oh My! Live Webcast February 6, :00 am PT
Fibre Channel Performance: Congestion, Slow Drain, and Over Utilization, Oh My! Live Webcast February 6, 2018 10:00 am PT Today s Presenters Ed Mazurek Cisco Earl Apellanes Broadcom Limited David J Rodgers
More informationFive Reasons Why You Should Choose Cisco MDS 9000 Family Directors Cisco and/or its affiliates. All rights reserved.
Five Reasons Why You Should Choose Cisco MDS 9000 Family Directors 2017 Cisco and/or its affiliates. All rights reserved. Contents Overview... 2 1. Integrated Analytics for Deep Visibility...3 2. Performance
More information1. Slow port emulation with R_RDY delay of us (1.5 seconds) 2. Port-monitor - slow port emulation with R_RDY delay of us (1.
Contents Introduction Topology Restrictions in Cisco NX-OS Software Releases Cisco NX-OS Software Release 5.2(8) Cisco NX-OS Software Releases Earlier than 5.2(6) Test 1: Slow Port Emulation with R_RDY
More informationDCNX5K: Configuring Cisco Nexus 5000 Switches
Course Outline Module 1: Cisco Nexus 5000 Series Switch Product Overview Lesson 1: Introducing the Cisco Nexus 5000 Series Switches Topic 1: Cisco Nexus 5000 Series Switch Product Overview Topic 2: Cisco
More informationIBM Europe Announcement ZG , dated February 13, 2007
IBM Europe Announcement ZG07-0221, dated February 13, 2007 Cisco MDS 9200 for IBM System Storage switches, models 9216i and 9216A, offer enhanced performance, scalability, multiprotocol capabilities, and
More informationCisco Exam Questions & Answers
Cisco 642-995 Exam Questions & Answers Number: 642-995 Passing Score: 800 Time Limit: 120 min File Version: 36.9 http://www.gratisexam.com/ Exam Code: 642-995 Exam Name: Unified Computing Troubleshoot
More informationUsing the Cisco NX-OS Setup Utility
This chapter contains the following sections: Configuring the Switch, page 1 Configuring the Switch Image Files on the Switch The Cisco Nexus devices have the following images: BIOS and loader images combined
More informationUsing the Cisco NX-OS Setup Utility
This chapter contains the following sections: Configuring the Switch, page 1 Configuring the Switch Image Files on the Switch The Cisco Nexus devices have the following images: BIOS and loader images combined
More informationThis section contains context-sensitive Online Help content for the Web Client > Monitor tab.
This section contains context-sensitive Online Help content for the Web Client > tab. Viewing Switch CPU Information, page 2 Viewing Switch Memory Information, page 2 Viewing Switch Traffic and Errors
More informationProduct Overview. Send documentation comments to CHAPTER
Send documentation comments to mdsfeedback-doc@cisco.com CHAPTER 1 The Cisco MDS 9100 Series Multilayer Fabric Switches provide an intelligent, cost-effective, and small-profile switching platform for
More informationDesigning and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches
Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches What You Will Learn The Cisco Unified Computing System helps address today s business challenges by streamlining
More informationCCIE Data Center Written Exam ( ) version 1.0
CCIE Data Center Written Exam (350-080) version 1.0 Exam Description: The Cisco CCIE Data Center Written Exam (350-080) version 1.0 is a 2-hour test with 80 110 questions that will validate that a data
More informationConfiguring Interface Buffers
This chapter provides information about interfaces buffers, its features, and how to configure the interface buffers Finding Feature Information, page 1 Information About Interface Buffers, page 1, page
More informationGetting Started. Enabling SSH
This chapter provides an overview of the basic configurations that need to be completed before getting started with IOA-specific configurations: Enabling SSH, page 1 Enabling CFS, page 2 IP Access Lists,
More informationCisco MDS 9000 Family Diagnostics, Error Recovery, Troubleshooting, and Serviceability Features
White Paper Cisco MDS 9000 Family Diagnostics, Error Recovery, Troubleshooting, and Serviceability Features July 2016 Author Fausto Vaninetti Consultant System Engineer, EBG Data Center Key Contributors
More informationThis table describes the supervisor module options for switches in the Cisco MDS 9000 Family.
This chapter describes how to manage switching and services modules (also known as line cards) and provides information on monitoring module states. About Modules, page 1 Maintaining Supervisor Modules,
More informationCisco Certdumps Questions & Answers - Testing Engine
Cisco Certdumps 642-996 Questions & Answers - Testing Engine Number: 642-996 Passing Score: 797 Time Limit: 120 min File Version: 16.8 http://www.gratisexam.com/ Sections 1. A 2. B 3. C 4. Exhibit Case
More informationAVANTUS TRAINING PTE LTD
Implementing Cisco Data Center Unified Fabric (DCUFI) 5 Days Instructor-Led Course Overview The Implementing Cisco Data Center Unified Fabric (DCUFI) v5.0 is a five-day instructor-led training course designed
More informationCCIE Data Center Lab Exam Version 1.0
CCIE Data Center Lab Exam Version 1.0 CCIE Data Center Sky rocketing Popularity should not come as any surprise As per Cisco Global Cloud index, published in 2012, gave prediction that by 2016 nearly two
More informationUCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.
UCS-ABC Why Firefly Length: 5 Days Format: Lecture/Lab Course Version: 5.0 Product Version: 2.1 This special course focuses on UCS Administration and Troubleshooting UCS Manager 2.0 and provides additional
More informationNext-Generation Cisco Nexus 7000 Series Switches and Modules and Cisco NX-OS Software Release 6.1
Product Bulletin Next-Generation Cisco Nexus 7000 Series Switches and Modules and Cisco NX-OS Software Release 6.1 PB717347 Cisco continues its leadership in data center switch technology and unified fabric
More informationEvolution with End-to-End Data Center Virtualization
Evolution with End-to-End Data Center Virtualization Yves Louis DC Virtualisation Technical Solution Architect Agenda Data Center Virtualization Overview Front-End Data Center Virtualization Core Layer
More informationCisco Prime Data Center Network Manager 6.2
Product Bulletin Cisco Prime Data Center Network Manager 6.2 PB639739 Product Overview Modern data centers are becoming increasingly massive and complex. Proliferation of new technologies such as virtualization
More informationN-Port Virtualization in the Data Center
N-Port Virtualization in the Data Center What You Will Learn N-Port virtualization is a feature that has growing importance in the data center. This document addresses the design requirements for designing
More informationTroubleshooting N-Port Virtualization
CHAPTER 9 This chapter describes how to identify and resolve problems that can occur with N-Port virtualization. It includes the following sections: Overview, page 9-1 Initial Troubleshooting Checklist,
More informationTS Open Day Data Center Fibre Channel over IP
TS Open Day Data Center Fibre Channel over IP Presented by: Rong Cheng- TAC LAN & DCN China Jan 30 th, 2015 2013 Cisco and/or its affiliates. All rights reserved. 1 FCIP Introduction FCIP Configuration
More informationUCS Engineering Details for the SAN Administrator
UCS Engineering Details for the SAN Administrator Craig Ashapa 2 First things first: debunking a myth Today (June 2012 UCS 2.02m) there is no FCoE northbound of UCS unless you really really really want
More informationCONNECTRIX MDS-9132T, MDS-9396S AND MDS-9148S SWITCHES
SPECIFICATION SHEET Connectrix MDS Fibre Channel Switch Models CONNECTRIX MDS-9132T, MDS-9396S AND SWITCHES The Dell EMC Connecrix MDS 9000 Switch series support up to 32Gigabit per second (Gb/s) Fibre
More informationAsseco SEE Macedonia. Goran Acevski. Advanced Infrastructure Services. Cisco Gold Partner
Asseco SEE Macedonia Cisco Gold Partner Goran Acevski Advanced Infrastructure Services Agenda Unified Computing System solution overview Overview of the UCS Mini system UCS M-Series, a unique new platform
More informationTroubleshooting Cisco Data Center Unified Fabric
Troubleshooting Cisco Data Center Unified Fabric Number: 642-980 Passing Score: 800 Time Limit: 120 min File Version: 1.0 http://www.gratisexam.com/ Exam A QUESTION 1 Which command displays the traffic
More informationCisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c)
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(4c) Release Date: April 5, 2011 Part Number: F0 This document describes the caveats and limitations for switches in the Cisco MDS 9000
More informationConfiguring Virtual Port Channels
Configuring Virtual Port Channels This chapter describes how to configure virtual port channels (vpcs) on Cisco Nexus 5000 Series switches. It contains the following sections: Information About vpcs, page
More informationP Commands. Send documentation comments to CHAPTER
CHAPTER 17 The commands in this chapter apply to the Cisco MDS 9000 Family of multilayer directors and fabric switches. All commands are shown here in alphabetical order regardless of command mode. See
More informationManaging System Hardware
CHAPTER 18 This chapter provides details on how to manage system hardware other than services and switching modules and how to monitor the health of the switch. It includes the following sections: Displaying
More informationCisco Nexus 4000 Series Switches for IBM BladeCenter
Cisco Nexus 4000 Series Switches for IBM BladeCenter What You Will Learn This document is targeted at server, storage, and network administrators planning to deploy IBM BladeCenter servers with the unified
More informationCONNECTRIX MDS-9250I SWITCH
Specification Sheet MDS-9250i CONNECTRIX MDS-9250I SWITCH Multipurpose Switch The Connectrix MDS-9250i Multilayer Switch offers up to forty 16 Gigabit per second (Gb/s) Fibre Channel ports, two 1/10 Gigabit
More informationCCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC
CCIE Data Center Storage Networking Fibre Channel Switching Configuration Nexus 5500UP FC Initialization Allocate interfaces as type FC slot 1 port 25 32 type fc FC must start at top of module and count
More informationFCoE Cookbook for HP Virtual Connect
Technical whitepaper FCoE Cookbook for HP Virtual Connect Version 4.45 Firmware Enhancements August 2015 Table of contents Change History 6 Purpose 7 Overview 7 Requirements and support 7 Supported Designs
More informationPASS4TEST. IT Certification Guaranteed, The Easy Way! We offer free update service for one year
PASS4TEST IT Certification Guaranteed, The Easy Way! \ http://www.pass4test.com We offer free update service for one year Exam : 642-359 Title : Implementing Cisco Storage Network Solutions Vendors : Cisco
More informationStorage Media Encryption Overview
CHAPTER 1 Encrypting storage media in the data center has become a critical issue. Numerous high profile incidents of lost or stolen tape and disk devices have underscored the risk and exposure companies
More informationCisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(1a)
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.0(1a) Release Date: February 22, 2010 Part Number: I0 This document describes the caveats and limitations for switches in the Cisco MDS
More informationCisco Nexus 7000 Series Supervisor Module
Cisco Nexus 7000 Series Supervisor Module The Cisco Nexus 7000 Series Supervisor Module (Figure 1) scales the control plane and data plane services for the Cisco Nexus 7000 Series system in scalable data
More informationVendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo
Vendor: Cisco Exam Code: 642-996 Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo DEMO QUESTION 1 Which three Cisco technologies or solutions are used during the virtualization
More informationCisco MDS 9000 Family NX-OS Licensing Guide, Release 6.x
Cisco MDS 9000 Family NX-OS Licensing Guide, Release 6.x Revised: July 10, 2017, OL-29297-02 Licensing Cisco MDS 9000 Series NX-OS Software Features Licenses are available for all switches in the Cisco
More informationBrocade Technology Conference Call: Data Center Infrastructure Business Unit Breakthrough Capabilities for the Evolving Data Center Network
Brocade Technology Conference Call: Data Center Infrastructure Business Unit Breakthrough Capabilities for the Evolving Data Center Network Ian Whiting, Vice President and General Manager, DCI Business
More informationCisco MDS 9100 Series Fabric Switches
Data Sheet Cisco MDS 9100 Series Fabric Switches Highlights Cost-effective, intelligent storage networking - Advanced features in a compact, cost-effective design simplify deployment and administration
More informationLAN Ports and Port Channels
Port Modes, page 2 Port Types, page 2 UCS 6300 Breakout 40 GB Ethernet Ports, page 3 Unified Ports, page 7 Changing Port Modes, page 10 Server Ports, page 16 Uplink Ethernet Ports, page 17 Appliance Ports,
More informationCisco Introduces the Cisco Nexus 2232TM-E 10GE Fabric Extender
Product Bulletin Cisco Introduces the Cisco Nexus 2232TM-E 10GE Fabric Extender PB715278 Cisco is introducing the Cisco Nexus 2232TM-E 10GE Fabric Extender as part of the Cisco Nexus 2000 Series Fabric
More informationThis guide presents the instructions and other information concerning the lab activities for this course.
DCICT Lab Guide 11/03/2013 Overview Outline This guide presents the instructions and other information concerning the lab activities for this course. This guide includes these activities: Activity 1-1:
More informationCisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(8c)
Cisco MDS 9000 Family Release Notes for Cisco MDS NX-OS Release 5.2(8c) Release Date: October 30, 2013 Part Number: This document describes the caveats and limitations for switches in the Cisco MDS 9000
More informationTech Note on Priority Transmit B2B Credits in MDS Switches
Tech Note on Priority Transmit B2B Credits in MDS Switches Contents Introduction Prerequisites Requirements Components Used Understand Priority Transmit B2B Credits in MDS Switch For an Inter-Switch Link
More informationConfiguring Virtual Port Channels
This chapter contains the following sections: Information About vpcs, page 1 Guidelines and Limitations for vpcs, page 10 Configuring vpcs, page 11 Verifying the vpc Configuration, page 25 vpc Default
More informationSend documentation comments to You must enable FCIP before attempting to configure it on the switch.
CHAPTER 9 (Fibre Channel over IP) is an IETF standards based protocol for connecting Fibre Channel SANs over IP based networks. encapsulates the FCP frames in a TCP/IP packet which is then sent across
More informationCisco Nexus 7000 Switches Second-Generation Supervisor Modules Data Sheet
Data Sheet Cisco Nexus 7000 Switches Second-Generation Supervisor Modules Data Sheet Product Overview The second-generation Cisco Nexus 7000 Supervisor Modules scale the control-plane and data-plane services
More informationCisco Nexus B22HP. Design and Deployment Guide. September, For further information, questions and comments please contact
Design and Deployment Guide Cisco Nexus B22HP Design and Deployment Guide September, 2011 For further information, questions and comments please contact ccbu-pricing@cisco.com 2011 Cisco and/or its affiliates.
More informationCisco Exam Questions & Answers
Cisco 642-996 Exam Questions & Answers Number: 642-996 Passing Score: 800 Time Limit: 120 min File Version: 38.8 http://www.gratisexam.com/ Cisco 642-996 Exam Questions & Answers Exam Name: Designing Cisco
More informationUCS 4+ Years of Lessons Learned by the TAC
UCS 4+ Years of Lessons Learned by the TAC Ken Krzyzewski - Technical Leader Cisco TAC Data Center & Virtualization Technical Leadership Team Agenda Introduction What went wrong? interactive scenarios
More informationCisco Nexus B22 Blade Fabric Extender for IBM
Cisco Nexus B22 Blade Fabric Extender for IBM Design and Deployment Guide 2014 Cisco IBM. All rights reserved. Page 1 Contents Introduction... 3 Network Diagram... 3 Hardware Installation... 5 Fabric Extender
More informationFCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch
FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch Document ID: 117280 Contributed by Padmanabhan, Cisco TAC Engineer. Mar 25, 2014 Contents Introduction Prerequisites Requirements
More informationNávrh serverových farem
Návrh serverových farem DCTECH4 Martin Diviš Consulting Systems Engineer mdivis@cisco.com Sponsor Sponsor Sponsor Sponsor Logo Logo Logo Logo CIscoEXPO 1 Agenda Introduction 5k/2k update Basic Concepts
More informationManaging Modules. About Modules. Send documentation comments to CHAPTER
CHAPTER 19 This chapter describes how to manage switching and services modules (also known as line cards) and provides information on monitoring module states. This chapter includes the following sections:
More informationConfiguring Virtual Port Channels
This chapter contains the following sections: Information About vpcs, page 1 Guidelines and Limitations for vpcs, page 10 Verifying the vpc Configuration, page 11 vpc Default Settings, page 16 Configuring
More informationCisco MDS 9710 Multilayer Director for IBM System Networking IBM Redbooks Product Guide
Cisco MDS 9710 Multilayer Director for IBM System Networking IBM Redbooks Product Guide This IBM Redbooks Product Guide introduces Cisco MDS 9710 Multilayer Director for IBM System Networking (9710-E08).
More informationCisco Nexus 5548P, 5548UP, 5596UP, and 5596T Switches
Data Sheet Cisco Nexus 5548P, 5548UP, 5596UP, and 5596T Switches Latest Additions to the Cisco Nexus 5000 Series Switches Cisco Nexus 5000 Series Switches Product Overview Today s data centers are increasingly
More informationInter-VSAN Routing Configuration
CHAPTER 16 This chapter explains the inter-vsan routing (IVR) feature and provides details on sharing resources across VSANs using IVR management interfaces provided in the switch. This chapter includes
More informationConfiguring Virtual Port Channels
This chapter contains the following sections: Information About vpcs vpc Overview Information About vpcs, on page 1 Guidelines and Limitations for vpcs, on page 11 Verifying the vpc Configuration, on page
More informationCisco Exam Questions & Answers
Cisco 642-997 Exam Questions & Answers Number: 642-997 Passing Score: 900 Time Limit: 120 min File Version: 36.4 http://www.gratisexam.com/ Cisco 642-997 Exam Questions & Answers Exam Name: Implementing
More informationConfiguring Online Diagnostics
Configuring Online s This chapter contains the following sections: Information About Online s, page 1 Guidelines and Limitations for Online s, page 4 Configuring Online s, page 4 Verifying the Online s
More informationCisco Nexus 1100 Series Virtual Services Appliances
Deployment Guide Cisco Nexus 1100 Series Virtual Services Appliances Deployment Guide Version 1.0 June 2013 2013 Cisco and/or its affiliates. All rights reserved. This document is Cisco Public Information.
More information45 10.C. 1 The switch should have The switch should have G SFP+ Ports from Day1, populated with all
Addendum / Corrigendum Dated 29/09/2017 Tender Ref No. - 236/387/DCCS/2010/IREDA/1 Dated: 22/09/2017 Name of Project - Supply Installation and Support Services of Data centers S. No. Document Reference
More informationvsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide
Technical white paper vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide Updated: 4/30/2015 Hongjun Ma, HP DCA Table of contents Introduction...
More informationCisco Cisco Data Center Associate Level Accelerated - v1.0 (DCAA)
Course Overview DCAA v1.0 is an extended hours bootcamp class designed to convey the knowledge necessary to understand and work with Cisco data center technologies. Covering the architecture, components
More informationCisco UCS Virtual Interface Card 1225
Data Sheet Cisco UCS Virtual Interface Card 1225 Cisco Unified Computing System Overview The Cisco Unified Computing System (Cisco UCS ) is a next-generation data center platform that unites compute, networking,
More information