A Variety of STREAM-MACHINE Models Available from 1 to 256 channels Direct Streaming to Disk Modular, High-isolation Signal Conditioning Powerful,

Size: px
Start display at page:

Download "A Variety of STREAM-MACHINE Models Available from 1 to 256 channels Direct Streaming to Disk Modular, High-isolation Signal Conditioning Powerful,"

Transcription

1 A Variety of STREAM-MACHINE Models Available from 1 to 256 channels Direct Streaming to Disk Modular, High-isolation Signal Conditioning Powerful, Easy to Use Acquisition & Analysis Software Portable and Rack-Mounting Form Factors MIL-STD-810F Ruggedness ISO-9001 & CE Mark

2 Get ready to enter a whole new world of capabilities in data acquisition. Where other systems stop, Dewetron is just getting started. Because we know that today, data acquisition involves a lot more than a few sensors there are ever-increasing demands on you to record other data as well. How about video, for example? Or audio? CAN Bus data? Position, speed, and distance information from GPS satellites? IRIG time code data? The list goes on. Only Dewetron systems allow you to record all of this and more simultaneously and in synch, regardless of the different sample rates from these various systems. And we didn t forget about sensor data that just keeps getting better and better with the advent of our own new A/D cards with 24-bit resolution, simultaneous sampling on all channels, robust anti-aliasing filtering, and more. We continue to expand our broad range of plug-in signal conditioning modules with more and better ones. Data from up to 4 CAN Bus interfaces can be acquired simultaneously. Record any and all CAN bus vehicle and passenger comfort parameters in synch with your sensor data! Up to four video cameras can be recorded in synch with your sensor, CAN, and other data. Supported cameras include synched firewire industrial cameras (up to 80 fps in color, or 240 fps in b/w), or consumer firewire and USB cameras (up to 30 fps) in several combinations. Dynamic and quasi-static signals from a wide variety of sensors can be connected directly to any Dewetron system via our DAQ, MDAQ, PAD, and EPAD signal conditioning modules. Many modules provide 1000 Vrms isolation. 2

3 Here are some but not all of the inputs that your Dewetron STREAM-MACHINE can record: Video from up to four Firewire and/or USB cameras Dynamic sensor data up to 128 channels Quasi-static sensor data many hundreds of channels CAN Bus data from up to four interfaces at once (potentially hundreds of total channels) IRIG time code, including a hard synch to the data GPS position, speed, distance, and satellites used data fast systems like the DEWE-VGPS provide 20 updates per second and persistant satellite connections for professional applications Your Dewetron system can be synched to incoming IRIG time code via the addition of an interface card and DEWESoft6. Microsecond-level synch can be achieved. Sensors like our DEWE-VGPS (and others) are fully supported in DEWESoft6. Real-time display of position, speed, distance, and a moving coordinate as well as number of satellites used. On replay, import a scaleable map for plotting! 3

4 A variety of Dewetron STREAM-MACHINE platforms are available choose the one that is the best balance of portability and expandability for your application. Our latest model is the DEWE-5000 (shown on the previous page). This is a notebook style system with a fold-up display and room for up to 16 plug-in modules on the front panel. Other popular portable models include the DEWE-3000 series, ideal for in-vehicle applications, and its slightly larger brother, the DEWE (which holds 16 modules). For pure rack-mounting applications we recommend the DEWE combined with our DEWE-RACK signal conditioning units. For applications where you need something that is both portable and/or rackmounting, and with Dewetron s legendary design, nothing outperforms the DEWE-4000, with its big 19 display, and room for 16 modules on the rear panel. For portable applications involving a notebook computer, see our DEWE-BOOK chasses. These are essentially DEWE- RACK expansion units that also have an internal A/D card that outputs to your notebook via USB (up to 100 khz) or Firewire (up to 1.25 MHz) or PCM-CIA (up to 1.25 MHz). Choose your Chassis: DEWE-5000 series DEWE-4000 series DEWE-3000 series PC base Industrial PC integrated integrated integrated CPU board ATX ATX Slot-CPU Connection from measuring amplifiers internal internal internal to A/D module Slots for A/D modules dynamic A/D modules dynamic channels up to 160 up to 160 up to 64 quasi-static A/D modules > 16 > 16 > 16 quasi-static channels > 128 > 128 > 128 Slots for measuring amplifiers internal slots external slots optional up to 144 optional up to 144 optional up to 56 Data thruput 3) Standard system 20 MB/s 20 MB/s 5 MB/s with STREAM option > 40 MB/s > 40 MB/s - Harddisk Standard system 120 GB 120 GB 40 GB Typ. duration of recording 1) 23.3 days 23.3 days 7.7 days Typ. duration of recording 2) 68 minutes 68 minutes 22.8 minutes with STREAM option > 200 GB > 200 GB - Typ. duration of recording 1) 38.8 days 38.8 days Typ. duration of recording 2) 1.9 hours 1.9 hours Dimensions Dimensions 460 x 351 x 200 mm 450 x 220 x 390 mm 372 x 258 x 165 mm 18.1 x 13.8 x 7.9 in x 8.7 x 15.4 in x 10.2 x 6.5 in. Weight typ. 16 kg (35.2 lb.) typ. 18 kg (39.6 lb.) typ. 8 kg (17.6 lb.) 1) 16 channels at á 1 ks/s 2) 16 channels at á 10 ks/s fps video 3) Because of new technologies data throughputs are increasing constantly. Please find the current values on our website 4

5 DEWETRON PC INSTRUMENT Sensor Measuring amplifier A/D converter Chassis Software DEWE-2000 series DEWE-700 & DEWE-RACK series DEWE-BOOK series integrated external notebook Slot-CPU ATX or Slot-CPU notebook internal analog (digital for PAD modules) USB or FireWire up to 128 up to 160 up to 16 >16 >16 >16 > 128 > 128 > /8/16/32/48/64 8/16 optional up to 112 optional up to MB/s 15 MB/s 2.5 MB/s >40MB/s >40MB/s GB 120 GB notebook dependent 23.3 days 23.3 days 68 minutes 68 minutes > 200 GB > 200 GB days 38.8 days 1.9 hours 1.9 hours 410 x 230 x 290 mm 137 x 109 x 145 mm 247 x 142 x 200 mm 16.1 x 9.1 x 11.4 in. up to 410 x 421 x 200 mm up to 410 x 142 x 200 mm 5.4 x 4.3 x 5.7 in. 9.7 x 5.6 x 7.9 in. up to 16.1 x 16.6 x 7.9 in. up to 16.1 x 5.6 x 7.9 in. typ. 12 kg (26.4 lb.) typ. 1 kg (2.2 lb.) up to 13.5 kg (29.7 lb.) typ. 3.5 (7.7 lb.) up to 6 kg (13.2 lb.) or request them from your sales engineer 5

6 Biomedicine / Sports Process and system control Efficiency measurements Mining / Drilling Energy production and power distribution Ppower plant optimization Power quality measurement Noise / Environmental studies Debugging Test bed applications Space QC / QA Service & Maintenance Manufacturing Automotive industry Research & development Rail / Truck Transportation Stress Testing Aerospace Chemical / Oil industries 6

7 DEWETRON THE STREAM-MACHINE Data acquisition, data-logging and transient recording for a wide range of applications Up to 128 high speed input channels Up to 256 data-logging channels 12-, 16- or 24-bit vertical resolution options Automatic anti-aliasing filters Up to 25 MS/s sample rate per channel (depending on used input module), 10 MHz bandwidth Independent and multiple trigger conditions for each channel On-line recording up to 100 GB continuously Up to four CAN buses with channel synchronization Up to four video cameras with simultaneous data acquisition Selectable sample rate per channel Comprehensive channel math functions Comprehensive data export to other applications, such as Excel, FlexPro, DIAdem TM, ASCII... Up to 19 TFT display with 1280 x 1024 pixel resolution Two displays simultaneously System Overview The STREAM-MACHINE is a multichannel, multi-function data recorder that acquires and stores data from a wide range of sensors, analog signals, digital signals, GPS signals, bus systems (CAN, Ethernet, RS-485) and video cameras... simultaneously! The system is expandable and also allows for upgrade as future technology develops DEWETRON STREAM-MACHINE Sensor Amplifier More than 20 different types available (galvanic isolation up to 3 kv PP,,...) A/D Converter Types with 12- to 24-bit and 100 ks/s up to 25 MS/s Chassis DEWE-5000 Series DEWE-4000 Series DEWE-3000 Series DEWE-2000 Series DEWE-RACK Series DEWE-BOOK Series Software DEWESoft FlexPro DASYLab LabVIEW TM Delphi TM, C TM, Visual Basic,... And we don t just collect data from up to 128 dynamic channels, 256 quasi-static channels, four RS-232/485 ports, four CAN bus ports, and four video cameras simultaneously...we show it to you in real-time, in brilliant, beautiful displays! Our award-winning DEWESoft data acquisition software incorporates the following functions and instruments: Data recorder Multichannel multimeter Oscilloscope Transient recorder FFT analyzer X/Y and Y/t recorder Video recorder Online analyzer with definable mathematical functions 7

8 Amplifiers with galvanic isolation CAN bus (4 x) Video (Up to 240 fps, 4 cameras) Data Export to FlexPro, & Excel (plus file export to TXT, MATLAB...) Position, distance & speed with GPS Data storage (CD, DVD, ZIP...) Counter / timer / incremental encoder (8 x) Data transfer (Ethernet LAN) Digital input (64 x) Wireless LAN option RS-232 / 485 ports (4 x) Time synchronization (GPS, IRIG, DCF77*) Report output (via LPT, USB, LAN, or Bluetooth ) Webcam (USB) Microphone Direct analog inputs to A/D board *IRIG is an American standard. and DCF77 is used in Germany 8

9 Direct Sensor Connection The measurement amplifiers available allow a wide range of sensors to be directly connected. With galvanic isolation and symmetrically free floating differential inputs, the user is assured of making accurate, disturbance-free measurements. All input amplifiers have filters and measurement ranges, which can be selected manually or in software (when the software runs, the local buttons are locked out). Real Galvanic Isolation Rough and tumble environments with floating earth potentials and electromagnetic interference make getting high quality measurements a real challenge. But that s why so many DEWETRON amplifiers provide powerful galvanic isolation (channel-to-channel and channel-to-ground), and have differential floating and symmetric inputs. We accept the quality measurement challenge! Anti-aliasing Protection Sensor Database Additionally a sensor database can be added for nonlinear sensors or for calibration data. TEDS sensors are also supported. Offline sensor calibration can be done with Excel, and then imported into DEWESoft! Digitizing AC signals can lead to measurement errors due to false or alias frequencies that are multiples of the original signal. The proven solution is to use measurement amplifiers with built-in anti-aliasing filters, and A/D hardware like our Orion cards, which provide 24-bit resolution and fully automatic aliasing protection. Length sensors Current clamps & converter Strain gages Torque and steering angle Angle sensors Speed sensors Symbol images 9

10 Multiple Sampling Rates The STREAM-MACHINE stores channel data at selected sampling rates and marks each measurement with a time stamp to provide channel-to-channel data correlation. Each channel has its own independent A/D converter (not multiplexed) and can be used simultaneously and synchronously with other channels having different sampling rates and trigger conditions. Sample configuration: Video (240 fps) Pressure (100 S/s) Temperature (1 S/s) GPS (20 S/s) Vibration (200 ks/s) Additionally a voice channel can be used for adding comments about the test being made. This is great for post-test analysis. The time reference comes from a quartz-stabilized source which can be externally synchronized via satellite (e.g., GPS), IRIG or DCF radio signals...or by inputting a digital impulse into multiple systems simultaneously. Freely Configurable Multi-channel Systems Depending on the desired vertical resolution (up to 24- bits) and sampling rate (up to 25 MS/s/ch) various A/D models are available. With an impressive 110 db signalto-noise ratio and up to 200 ks/s per channel, our 24- bit Orion card is ideal for signal analysis, FFT and transient processes in electro-mechanical fields. For electrical applications requiring 25 MS/s, one of our 12- bit Spectrum cards would be a better choice.(faster cards are also available - discuss your requirements with us!) Channels Resolution per module Dynamic A/D converter Channels per system Sample rate per channel 24-bit 16 > ks/s 16-bit 16 > ks/s 12-bit 16 > ks/s 12-bit / HS MS/s 12-bit / SHS MS/s 12-bit / XHS MS/s Quasi-static A/D converter 24-bit 8 > S/s The measurement system can record channel data from up to 128 dynamic A/D boards simultaneously with synchronized clocking of all channels. Triggering and File Management The DEWETRON STREAM-MACHINE provides several useful data recording modes: Stream Function In this mode, all of the analog, CAN bus, and video data are continuously streamed to the 100 GB hard drive - video data at up to 240 fps, and 16 analog channels, each with 10 ks/s, and 50 CAN bus channels with 100 samples/s can be sampled for up to 100 minutes. Analog channels CAN channels Video Requiered memory Duration of streaming 16 x 100 S/s - - ca kb/s typ. 1/2 year 16 x 1 ks/s 50 x 100 S/s - ca kb/s typ. 8.5 days 16x10kS/s - - ca.620.5kb/s typ.2days 16 x 10 ks/s 100 x 100 S/s 100 fps ca. 30 MB/s typ. 1 hour Multi-trigger Function Each channel has independent triggering, and you may combine them using OR trigger logic. You may also set trigger exceptions, to prevent unwanted triggers (like when a machine is stopped, or during a reset operation). Each trigger event starts recording with adjustable preand post-trigger time, plus a variable hold-off time. The software can also detect triggers which occur during the post-trigger phase, and can automatically lengthen the acquisition so that none are missed! (This feature can be turned on or off). Illustration of the trigger events. 10

11 Trigger Functions: The following trigger conditions can be applied to any channel in your system not just the analog or dynamic channels. You can trigger from CAN bus and mathematical channels as well. Example of multiple trigger settings Edge-trigger, filtered edge trigger Trigger on rising edge when the threshold has been crossed Trigger on falling edge when the threshold has been crossed Window trigger Trigger when signal enters the range between two definable threshold levels Trigger when signal leaves the range between two definable threshold levels Pulse width trigger Trigger on positive pulse at trigger level when width is longer than a definable period Trigger on positive pulse at trigger level when width is shorter than a definable period Trigger on negative pulse at trigger level when width is longer than a definable period Dynamic Sampling Rate Switching In dual speed mode, a second sampling rate can be used when a trigger is not active. In parallel, two separate video speeds for standard and triggered recording can be used. The slower recording captures and displays min/max data based on the higher sample rate! This means that you don t lose the overall amplitude signature even when storing at reduced rates. You can store reduced continuously, and at a higher rate when a trigger happens and it s completely automatic - just set it up and let it go! Trigger on negative pulse at trigger level when width is shorter than a definable period Window and pulse width trigger Trigger when the signal stays for more than a defined period between two threshold values. Trigger when the signal stays for less than a defined period between two threshold values. Trigger when the signal stays for more than a defined period outside of two threshold values. Trigger when the signal stays for less than a defined period outside of two threshold values. Slope trigger Trigger when the signal rise-time between two thresholds is shorter than a definable time Trigger when the signal rise-time between two thresholds is longer than a definable time Trigger when the signal fall-time between two thresholds is longer than a definable time Trigger when the signal fall-time between two thresholds is shorter than a definable time 11

12 User Interface Easy to use Graphical user interface makes all function easy to visualize, and to use! DEWESoft is in a class all by itself take a look for yourself! Setup Screen Set up your sample rate, data file name, signal conditioners, and trigger conditions it s easier than ever with DEWESoft. Multi-zoom and cursor Multi-zoom functions and a reference cursor provide quick and easy data comparison between channels. Unlimited User Setups Your setups can be saved and saved as in as many combinations as you need store a few, or millions, on the huge hard drive! Setup parameters can also be printed to paper or PDF reports for documentation and ISO9000 compliance. Virtually every aspect of the software is saved within the setup, and is restored automatically when you load a data file later (even on a different computer!). Online analysis and display In the STREAM-MACHINE, data from different sources, acquired at different sampling rates, can be processed using mathematical formulas, and the results displayed online! Standard math is augmented with trigonmetric, integration, differentiation, boolean, and programmable digital filter functions. Data Integrity The raw data cannot be altered within the program, complying with international conventions about data integrity. 12

13 Overview Display Create whatever you want on this display, with sizeable analog and digital meters, scopes, horizontal and vertical recorder graphs, FFT windows, bar graphs, programmable LED s, video windows, and even GPS tracks! View your data on-line during acquisition, and also during replay using the PLAY and SPEED controls. Nothing else even comes close. FFT A powerful FFT analyzer provides line adjustment from 256 to 64k, window functions (Hamming, Hanning...), linear and log displays, high-pass filtering and averaging, A, B, C and D weighting, and more! Pop up windows show the max RMS and frequency peaks, and you can click any part of the FFT display area to add a dynamic mark showing the Hz and magnitude. Chart Recorder Horizontal and vertical (shown) chart recorder displays show your data over a long period of time (hours, days, weeks...). We ve emulated several popular displays to allow replacement of older strip chart recorders! Octave Octave analysis is a special form of FFT analysis often used in sound analysis. DEWESoft provides not only the classic 1/3 octave, but also 1/1, 1/3, 1/12, 1/24 octave on-line displays! Scope The oscilloscope mode allows signals to be analyzed in the microsecond range. Scale and position signals on the fly, and use triggering to freeze areas of interest. X-Y Recorder Recorded data may also be displayed as X/Y so that externally clocked signals such as crank-shaft referred signals can be displayed. 13

14 Video Data A camera is just a sensor, right? So why not use it to add context and meaning to our test data? Several cameras of different speeds and resolutions connect directly to the STREAM-MACHINE via both USB and IEEE (FireWire ). Stream Mode Continuous recording of up to 100 GB of data (at 30 fps) can be compressed to MPEG on-line. Even a compression factor as high as 20:1 results in little, if any, noticeable loss of image quality. Triggered Mode As with analog recording, pre- and post-triggering is also available for video recording! Capture what happened before the trigger...even with video! (Four cameras can be connected simultaneously) Mixed Mode During long, slow sample rate recording a fast event can be used to trigger a second, high sample rate recording with pre- and post-trigger. Timed video recording can also be achieved with a rotationally synchronized video recording (strobe) using an external trigger. Industrial color cameras as well as black and white cameras can be triggered up to their maximum frequency using such a strobe. Data Compression: Popular, industry standard compression formats can be used to save disk space. Video up to 30 fps can be compressed in real-time. Higher frame rates can be compressed off-line (immediately after recording) and your can select the compression ratio up to 50:1 (this reduces a 1 GB video to 20 MB). You can trigger video recording as well, and even use the dual-speed acquisition of video just as you can with sensor/signal data! This saves lots of disk space, and reduces the time and effort needed to analyze your data. 14

15 New Concept: Moving Documentation! In addition to printed and flat file documentation the STREAM-MACHINE can also generate video sequences that can be exported as an AVI video and sent by ! GPS data and time code, IRIG In parallel with the analog & digital sensor data, video data and CAN bus data you can also acquire position, velocity and time data from GPS. A variety of GPS interfaces can be used, according to the update rate, resolution, and information required. A typical standard GPS sensor delivers a position data and a time stamp once per second. Such sensors are inexpensive and easy to interface via RS232 or USB. CAN bus data The STREAM-MACHINE offers parallel recording of up to four CAN bus ports with hardware synchronization of the CAN bus analog data. For analysis a CAN bus protocol editor is available, databases that are already available may also be used (*.DBC filter). Our own DEWE-VGPS delivers high precision position data at 20 Hz, enabling on-line calculation of direction, speed and acceleration. Heavily used by the automotive and train industry for acceleration and deceleration/brake tests. IRIG is the standard range time for the American aerospace industry. Your Dewetron system can be hard-synched to IRIG-A, - B, H & NASA 36 codes! The number of satellites used is accessible, and can be displayed and recorded just like any other channel! > The Overview screen showing IRIG day and time data very large in the upper right-hand corner < 15

16 Data Analysis and Exporting The completely new database concept makes it possible to find events quickly and easily even in large data files (100 GB or more). Using ActiveX or file export the data can be transferred to Excel, FlexPro, MATLAB, UFF58, I-DEAS, Famos, DIAdem TM, nsoft TM, ME scope TM or in ASCII format to other software. With the help of cursors and zooming, you can isolate events of interest and make reports Video data can be exported as moving documentation in popular formats like AVI, DivX, and MPEG. or copy and paste directly into popular programs like Microsoft Excel and Microsoft Word. Royalty-Free Analysis DEWESoft can be installed without a license on any computer for use of the analyze mode! You can freely use the program to review data, make new exports and printed reports. 16

17 Networking The STREAM-MACHINE can be networked via TCP/IP (Ethernet recommended, but modem is also supported) for remote control and online data transfer to a server. ActiveX Plug-ins ActiveX has been in use for some time in Excel and FlexPro for the transfer of data, and now this port can be used bidirectionaly. ActiveX plug-in's can be used to extend the capabilities of DEWESoft 6 (requires -PROF version). Remote Control and Synchronicity Several STREAM-MACHINE s can be connected together as illustrated below: Benchmarks Typical capacity: Sample rate analog signals Signals 1 sec 1 ms 10 µs 16Analoginputs(24Bit) 64B/s 62.5kB/s 6.1MB/s 64 Analog inputs (16 Bit) 128 B/s 125 kb/s 12.2 MB/s 50 x CAN-messages (10 Hz) 7.8 kb/s GPS (e.g., 20 Hz VGPS) 0.65 kb/s 30 fps color 8.8 MB/s 240 fps b/w 17.6 MB/s There is usually at least 100 GB available for recording data. The max data rate in total for the hard disk is 40 MB/s. Keeping in mind that we have to account for all active channels, the typical recording period can be caculated as follows: Through the use of new technologies 100% synchronicity can be achieved. Using remote control, any number of systems can be singly or jointly controlled. Examples: 16 Analog channels 1 ks/s/ch: 100 GB 104,857,600 kb Recording duration [s] = = = 3,276,900 s = 37.4 days 32 kb/s 32 kb/s 64 Analog channels 1 ks/s/ch: 100 GB 104,857,600 kb Recording duration [s] = = = 838,861 s = 9.7 days 125 kb/s 125 kb/s 16 Analog channels 24-bit 100 ks/s/ch, 240 fps: 100 GB 102,400 MB Recording duration [s] = = = 4,321 s = 72 min. 61 MB/s 23.7 MB/s MB/s 17

18 DEWETRON STREAM-MACHINE Sensor Measuring amplifier A/D converter Chassis Software Input Configuration Signal / Sensor Measuring amplifier Channels Specifications Dynamic: Voltage, current and sensors with voltage- and current output Shunt DAQx-V Series 1 ±10 mv.. ±50 V (±0.05 %), DC.. 50 khz, galvanic isolation Voltage DAQx-DMM Series 1 ±10 V.. ±1000 V (±0.1 %), DC.. 20 khz, galvanic isolation Current(-clamps) DAQP-uV 1 ±500 µv.. ±25 mv (±0.1 %), DC.. 20 khz Sensors with DAQN-AIN 1 Range and input type depends on aquisition card, DC.. 35 khz, integrated amplifier overvoltage protection up to 500 V Dynamic: Direct multichannel connecting for voltage, current and sensors with voltage- and current output Shunt MDAQ-V Amplification 0.1 or 1 (typ. ±100 V or ±10 V), DC khz, Voltage differential signal input, Overvoltage protection up to 500 V Current(-clamps) MDAQ-V Amplification1or10(typ.±10Vor±1V),DC..50kHz, Sensors with differential signal input, overvoltage protection up to 100 V integrated amplifier Quasi-static: Voltage, current and sensors with voltage- and current output Shunt PAD-V8-P 8 ±100 mv.. ±50 V (±400 µv), DC.. 3 Hz, galvanic isolation Voltage for each channel, 8 integrated A/D converters with 24-bit, 6 S/s Current(-clamps) Pressure- and force measurement with strain gauges Strain gauges DAQP-BRIDGE 1 ± mv (±0.05 %), DC.. 5 khz, V DC excitation, Strain gauge sensors full bridges, ¼ and ½ with external completion DAQP-BRIDGE-A 1 ± mv (±0.1 %), DC.. 20 khz, V DC excitation, ¼, ½ and full bridges, galvanic isolation DAQP-BRIDGE-B 1 ± mv (±0.05 %), DC khz, V DC excitation, ¼, ½ and full bridges Force-, vibration-, acceleration- and noise measuring ICP Sensor DAQP-ACC-A 1 ICP amplifier 1x.. 100x (±0.5 %), 0.5 Hz khz, Measuring microphone 4 / 8 ma supply, 0.5 or 5 Hz high pass filter Piezo electric sensor DAQP-CHARGE-A 1 ICP und charge amplifier db / mv/pc (1 %), 0.1 Hz.. 50 khz, selectable single and double integration DAQP-CHARGE-B 1 Charge amplifier ±100.. ± pc (±0.5 %), drift < 0.03 pc/s, DC khz, galvanic isolation Length- and distance measuring Potentiometric sensors DAQN-POT 1 Potentiometric sensors 100 Ohm.. 10 kohm, Inductive sensors DC Hz, ±0.2 V DC supply, galvanic isolation LVDT sensors DAQP-TRQ 1 Inductive and LVDT sensors, mv/v (0.1 %), Rope sensors DC.. 1 khz, 2.3 V RMS / 5 khz supply Rotation angle sensors Frequency measuring, pulse signals Optical sensors DAQP-FREQ-A Hz khz F/U converter, ±0.05 %, div. in- and output Incr. impulse transd. filters, AC/DC coupling, auto trigger, analog- and trigger output Binary state information PAD-CNT2 2 1 Hz khz counter, V (open collector) PAD-DI8 8 Digital inputs V (6x isolated, 2x shared ground) Temperature measuring Thermocouples DAQN-THERM 1 Thermocouples type K, J or T (typ. ±0.2 %), DC.. 4 Hz (up to 300 Hz on request), galvanic isolation Pt100 probes DAQN-RTD 1 2- or 4-wire Pt100 (±0.1 %), DC.. 10 Hz PAD-TH8-P 8 Thermocouples type K, J or T or V..1.5 V, galvanic isolation for each channel, 8 integrated A/D converters with 24-bit, 6 S/s optional: Pt100 adapter Find specification details in current datasheets and manuals on 18

19 DEWETRON STREAM-MACHINE Sensor Measuring amplilfier A/D converter Chassis Software Configuration of Dynamic A/D Cards p p / A/D module Channels Simultaneous Resolution Sample rate Sample rate Max. Module /module sampling /channel total data stream DAQx MDAQ PAD DEWE-ORION yes 24-bit 200 ks/s 3.2 MS/s 12.8 MB/s MI yes 12-bit 1 MS/s 8 MS/s 16 MB/s MI yes 12-bit 10 MS/s 80 MS/s 160 MB/s MI yes 12-bit 25 MS/s 200 MS/s 400 MB/s no 12-bit 12.5 ks/s 200 ks/s 400 kb/s no 12-bit ks/s 1.25 MS/s 2.5 MB/s no 16-bit 12.5 ks/s 200 ks/s 400 kb/s no 12-bit ks/s 1.25 MS/s 2.5 MB/s no 16-bit 1.56 ks/s 100 ks/s 200 kb/s DEWETRON STREAM-MACHINE Sensor Measuring amplifier A/D converter Chassis Software Configuration of Quasi-static A/D Modules A/D module Channels Simultaneous Resolution Sample rate Sample rate Max. Signals /module sampling /channel total data stream PAD-V8-P 8 yes 24-bit 8 x 6 S/s 48 S/s 192 Bytes/s Voltage inputs PAD-TH8-P 8 yes 24-bit 8 x 6 S/s 48 S/s 192 Bytes/s Temperature probes PAD-TH8-P with CB8-RTD 8 yes 24-bit 8 x 6 S/s 48 S/s 192 Bytes/s Pt100/Pt1000 PAD-CNT2 8 yes 32-bit 8 x 6 S/s 48 S/s 192 Bytes/s Counter PAD-DI8 8 yes 1-bit 8x6S/s 48S/s 48Bytes/s Digitalinputs 19

20 DEWETRON STREAM-MACHINE Sensor Measuring amplifier A/D converter Chassis Software Software Selections Data / Video Acquisition Software DEWESoft Easy to use software for the STREAM-MACHINE. DEWESoft turns your DEWETRON systems into a powerful suite of instruments. You can easily replace multimeters, recorders, oscilloscopes, FFT analyzers, X-Y recorders, and tape recorders. Online math channels, programmable digitial filters as well as freely adjustable triggers. An amazing user-defineable overview screen allows to show all instruments in parallel! DEWESoft supports easy data export to many common analysis software packages (FlexPro, Excel, DIAdem TM...) as well as printing your reports directly from DEWESoft. Several versions of DEWESoft are available. The standard edition is - SE, which includes DirectX video and all major data acquisition functions. The -PROF version adds support for multiple A/D cards, special cards, advanced FRF & Octave analysis, and synchronized video using our Basler cameras. -LT versions are available for systems with only PAD modules, and for systems with only an A/D board (no signal conditioning). Data Analysis Software FlexPro What s a Few Billion Data Points Between Friends? If you re like most engineers, you like to use Microsoft Excel for quickly charting some test data. That program is well-known, and nearly everyone has it. But Excel was never intended for data acquisition, and therefore it can only open 64 or 128 thousand rows of data, which isn t much in terms of data acquisition. And charts are limited in most versions of 16 thousand points. So how can you view, plot, and analyze data files that are typically much larger than these limitations...without giving up the familar user interface of Excel? The answer is FlexPro. Designed with a very Excellike user interface (the chart wizard is especially familiar), FlexPro has no limitations about record length, file size, or number of points in a chart. The ActiveX interface allows one-click export of your data from DEWESoft directly into FlexPro. You can even create and manage templates or scripts, for automated exporting and analysis a huge time-saver. FlexPro comes with a huge array of mathematical functions, including programmable filtering, fast fourier transforms, and a robust statistics suite. If you get the Professional version, you can even program FlexPro using VBA or a scripting tool. Great charting and powerful interactive display a and reports are included, so that you can create just the right output (2D and 3D diagrams, tables, and more). FlexPro processing speed is impressive - files of many MB are processed in a fraction of a second. Development Software DASYLab... LabVIEW... and Others Choice of Development Platforms Most STREAM-MACHINE owners don t want to change careers and become programmers...but sometimes off-the-shelf data acquisition software, no matter how powerful, just doesn t do what you need it to do. Or perhaps you want to create something really custom...what can you do? Good news the Dewetron STREAM-MACHINE is the ideal development platform for a wide variety of data acquisition and process control instruments. Because it s a standard, open architecture computer, it is compatible with today s best and most popular software development tools. For rapid prototyping and implementation, nothing beats DASYLab. The no-programming design of DASYLab allows you to put together a custom application in a shorter time than you ever imagined was possible. DASYLab includes drivers for a broad range of data acquisition hardware from many vendors, as well as point-and-click support for interfaces such as ModBus, Ethernet, serial, and PID. Create your own custom screens as easily as drawing them, and automate just about anything. DASYLab is available directly from Dewetron, and when we install it, will even contain a Dewetron menu for directly controlling your DAQ and PAD series plug-in signal conditioners. More Power, More Extensibility But then there are times when nothing but LabVIEW will do the job, and your Dewetron STREAM-MACHINE is 100% compatible with the world s most popular development platform for data acquisition. We even provide an ActiveX object for controlling our signal conditioners that you can link into your application, reducing development time immensely. And because your STREAM-MACHINE can contain an NI A/D board, there are no compatibility issues to deal with regarding the hardware. LabVIEW programmers rejoice someone built a portable, robust computing platform for you! 20

21 DEWETRON STREAM-MACHINE Sensor Measuring amplifier A/D converter Chassis Software Options for measuring systems Option Sensors On request we also supply various sensors with your system, e.g., current probes, thermocouples, pressure transmitter, transmitters, acceleration sensors... Option Touchscreen Optional touchscreen for easier operation of the measurement systems FireWire IEEE-1394 camera Mobile displays Different models: External high brightness TFT displays with up to 80 fps color wide viewing angle up to 240 fps black/white various sizes of 6", 12" and 15" GPS systems Car seat mounting kit 3 different GPS systems are available Comfortable and safe fixing of the systems (see page 11) on the car seat; for all car types Convenient signal connection to your DEWETRON system Connect all sensor signals directly to your DEWETRON measurement system. Several connector options and -blocks are available Options for easy signal connection to your DEWETRON amplifiers Many connector options are available for all DEWETRON amplifiers ranging from simple screwterminal adapters to high precision thermocouple blocks Interface modules CAN bus interfaces with 1 or 2 channels per card for automotive applications IEEE-1394 FireWire interface for synchronised video applications; RS-485 interface Carrying case All systems are shipped with a carrying bag. As an option we offer common-carrier rated shipping/carrying cases for safe transportation Typical DEWETRON systems (examples) 160 channels measuring system for automotive uses: Multi-channel measuring system: 16 dynamic channels in the basic system 80 channels - each with 144 dynamic channels in the expansion rack 200 ks/s and 24-bit resolution Test systems for SPS-service: Transient recorders: 16 dynamic channels via USB or FireWire 40 channels - each with 25 MS/s 21

22 We ve created versions of the STREAM-MACHINE to address specific applications. Most of these products have their own separate brochure, but for your reference, here is a high-level review of what s available from Dewetron: DEWE-XXXX-DSA Dynamic Signal Analyzers PURPOSE For shock & vibration measurements, sound and acoustic analysis, shaker table and modal work. BASICS 16-ch platforms, expandable in 16-ch steps. 110 db dynamic range, 24-bit resolution, 200 ks/s maximum sample rate, anti-aliasing built-in SYSTEMS Available for all major Dewetron platforms, including DEWESoft-Prof software, FlexPro- STD analysis software, and a choice of signal conditioning for all accelerometer types (with and without plug-in modules) Systems Max BNC connectors Max Dewe-Modules Max. A/D cards DEWE-5000-DSA DEWE-5000-DSA-RACK DEWE-2010-DSA DEWE-2010-DSA-RACK DEWE-3010-DSA DEWE-3010-DSA-RACK DEWE-4000-DSA DEWE-4000-DSA-RACK DEWE-700-DSA DEWE-XXXX-TR Transient Capture PC-Based Scopes PURPOSE For high-speed transient capture, replacing light beam oscillographs and digital storage scopes BASICS Choice of platforms and wide range of Spectrum series A/D cards, with sample rates as high as 500 MHz, and with vertical resolution from 8- to 16-bits (depending on speed). SYSTEMS Available for all major Dewetron platforms, including DEWETrans software, FlexPro- STD analysis software, and a choice of signal conditioning for sensor types (with and without plugin modules) Systems Max BNC connectors Max Dewe-Modules Max. A/D cards DEWE-5000-TR DEWE-5000-TR-RACK DEWE-2010-TR DEWE-2010-TR-RACK DEWE-3010-TR DEWE-3010-TR-RACK DEWE-4000-TR DEWE-4000-TR-RACK DEWE-700-TR Popular 12-bit Spectrum Boards Model Name Channels Sample Rate/ch MI MS/s MI MS/s MI MS/s MI MS/s MI MS/s MI MS/s MI MS/s MI MS/s MI MS/s MI MS/s MI or or 50 MS/s MI ,2 or 4 200, 100 or 50 MS/s Popular 14-bit Spectrum Boards Model Name Channels Sample Rate/ch MI MS/s MI MS/s MI MS/s MI MS/s Popular 16-bit Spectrum Boards MI ks/s MI ks/s MI ks/s MI ks/s MI MS/s MI MS/s Popular 8-bit Spectrum Boards Model Name Channels Sample Rate/ch PCI or or 250 MS/s PCI or or 100 MS/s Please note that systems can be created with virtually any combination of Spectrum cards. The included DEWETrans software can use them all simultaneously, even if they are using different sample rates and memory depths. Within the capabilities of the computer, data can be streamed to disk. Above that limit, data are captured to memory on the Spectrum board, then immediately transferred to the system hard disk drive, for maximum transient capture performance and high-speed triggering. Ask us about your application, and how one of our DEWE-XXX-TR products might be a perfect fit for your requirements. 22

23 DEWE-XXXX-CA Combustion Analyzer Systems PURPOSE Engine tuning, esp. the ECU of internal combustion systems. Angle-based measurements, including pressure/volume display, knocking detection, and more. BASICS Up to 0.1 resolution using crank angle encoder, on-line math and stats, and more. SYSTEMS Available for all major Dewetron platforms, including DEWE-CA software, DEWESoft for general purpose use, and FlexPro-STD analysis software, and a choice of signal conditioning for sensor types (with and without plug-in modules) PROFESSIONAL Versions Max Sample Rate/ch Display Size Configuration DEWE-5000-CA-PROF 1 MS/s 17 Portable, in-car DEWE-2010-CA-PROF 1 MS/s 15 Portable, in-car DEWE-4000-CA-PROF 1 MS/s 19 Benchtop DEWE-700-CA-PROF 1 MS/s 17 Rack-mounting LOW-COST Versions Max Sample Rate Display Size Configuration DEWE-5000-CA-LC 1 MS/s total 17 Portable, in-car DEWE-2010-CA-LC 1 MS/s total 15 Portable, in-car DEWE-4000-CA-LC 1 MS/s total 18 Benchtop DEWE-700-CA-LC 1 MS/s total 17 Rack-mounting DEWE-XXXX-IPC Portable Industrial Computers PURPOSE The industrial PC ( IPC ) version of our platforms are extremely popular among OEM s, especially in the aerospace market. BASICS MIL-STD shock and vibration specs, bright displays, and PCI slots allow our customers to add their own 1553, ARINC, and other interface cards and create unique portable systems. SYSTEMS Available for all major Dewetron platforms, see the chart below for a short crossreference of system basics. Contact your local Dewetron dealer for more info, or visit us on-line. Platform CPU type Display PCI ISA Std Drives Opt Drives DEWE-5000-IPC ATX M/B H, C Z, D, R, S DEWE-4000-IPC ATX M/B H, C, F Z, D, R, S DEWE-2010-IPC-S1 Slot CPU H, C, F Z, D, R, S DEWE-2010-IPC-S2 Slot CPU H, C, F Z, D, R, S DEWE-2010-IPC-S3 Slot CPU H, C, F Z, D, R, S DEWE-2000-MAX Slot CPU H, F Z, D, R, S DEWE-3010-IPC Slot CPU H, C, F Z, D, R, ES DEWE-700-IPC ATX M/B [ext l] 5 -- H, C, F Z, D, R, S DEWE-600-IPC SlotCPU /4 -- H ez, ed, ef, es Std Drives: H = Internal HDD; C = CD-R/W; F = FDD Opt Drives: Z = ZIP; D = DVD-R/W; R = Removable HDD; S = SCSI (e = external only) (Certain drive combinations may not be possible in the same system) Fractional slot quantity indicates the slot is not full length and/or height For example, 4.5 means four full size slots and one smaller slot 23

24 DEWETRON STAFFED OFFICES: Austria Belgium, Netherlands, Luxembourg China The Czech Republic Germany Hong Kong Italy Malaysia Singapore South Korea Switzerland The United Kingdom The United States of America DEWETRON REPRESENTATIVES: Australia Canada Central America/Costa Rica Finland France India Japan New Zealand Norway Spain Sweden Taiwan Thailand Vietnam Sales Headquarters for North & South America: DEWETRON INC. PO Box 1460, Charlestown, RI USA USA Toll-free: Telephone: Fax: (Timezone GMT -5) Sales Headquarters for Europe and Asia: DEWETRON Ges.m.b.H, Parkring 4, A-8074 Graz-Grambach AUSTRIA Telephone: Fax: (Timezone GMT+1) YOUR LOCAL REPRESENTATIVE: DE-B0391E All trademarks are acknowledged to be the property of their owners. Specification subject to change without notice. DEWETRON Ges.m.b.H. 1/2004

DEWE-43 UNIVERSAL USB INSTRUMENT. 8 analog multi-sensor inputs 8 counter inputs 2 CAN-bus interfaces CPAD2 expansion for low speed ed temperature

DEWE-43 UNIVERSAL USB INSTRUMENT. 8 analog multi-sensor inputs 8 counter inputs 2 CAN-bus interfaces CPAD2 expansion for low speed ed temperature www.dewetron.com DEWETRON UNIVERSAL USB INSTRUMENT The high end DEWETRON performance with the easy of use DEWESoft, the entry product with 8 analog multi-sensor inputs 8 counter inputs 2 CAN-bus interfaces

More information

Tactical/Land Vehicle Test.

Tactical/Land Vehicle Test. Automotive Energy & Power Analysis Aerospace Transportation General Test & Measurement Tactical/Land Vehicle Test DEWETRON makes systems that are compact and rugged enough for use inside all kinds of tactical

More information

...the precision signal conditioning company. Combustion Analyzer Series. Automotive Research & Development.

...the precision signal conditioning company. Combustion Analyzer Series. Automotive Research & Development. Automotive Research & Development Diagram Diagram assistant System settings Combustion Analyzer Series The DEWETRON combustion analyzers are innovative systems for engine testing. The unit is very easy

More information

Mainframes. Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2. Please find further solutions in chapter DEWE2

Mainframes. Software Components Signal Conditioning Front-ends Instruments Dedicated Instruments DEWE2. Please find further solutions in chapter DEWE2 Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement Mainframes DEWETRON Mainframes are combining a ruggedized PC with signal conditioning, A/D card and software.

More information

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise!

Let`s get SIRIUS! SIRIUS Overview. SIRIUS from Dewesoft. SIRIUS Overview. The new hardware generation makes your measurement more precise! Overview NEW dual ADC Overview Let`s get! The new hardware generation makes your measurement more precise! Dual core Input from Dewesoft This new technology solves the often faced problem that the signal

More information

DEWE-3041 SideHAND series

DEWE-3041 SideHAND series Automotive Energy & Power Analysis Aerospace Transportation General Test & Measurement DEWE-3041 SideHAND series Benchtop Data Acquisition Systems In 2004 Dewetron broke all the rules by creating a powerful

More information

Gbit Ethernet USB 3.0. TRIONet FOR DISTRIBUTED, SYNCHRONOUS MEASUREMENTS

Gbit Ethernet USB 3.0. TRIONet FOR DISTRIBUTED, SYNCHRONOUS MEASUREMENTS Gbit Ethernet USB 3.0 TRIONet FOR DISTRIBUTED, SYNCHRONOUS MEASUREMENTS DEWETRON TRIONet THE UNIERSAL MEASUREMENT SOLUTION TRIONet the flexible measurement system for local or distributed measurements.

More information

6220 Ethernet-Based Voltage Measurement Module

6220 Ethernet-Based Voltage Measurement Module Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100 khz per channel sample rate ±10 V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger modes

More information

Current Collector Test on Trains. Transportation Train Test - Current

Current Collector Test on Trains.  Transportation Train Test - Current Automotive Energy & Power Analysis Aerospace Transportation General Test & Measurement Current Collector Test on Trains Most trains in metro areas operate from DC voltage, which is carried either by a

More information

SIRIUS. The next instrument generation SIRIUS

SIRIUS. The next instrument generation SIRIUS The next instrument generation Fast data recorder High dynamic range 160 db; 100 times better than 24 bit systems Isolated input amplifiers for any sensor/signal Analog output, function generator or file

More information

Gbit Ethernet USB 3.0. TRIONet FOR DISTRIBUTED, SYNCHRONOUS MEASUREMENTS

Gbit Ethernet USB 3.0. TRIONet FOR DISTRIBUTED, SYNCHRONOUS MEASUREMENTS Gbit Ethernet USB 3.0 TRIONet FOR DISTRIBUTED, SYNCHRONOUS MEASUREMENTS DEWETRON TRIONet THE UNIERSAL MEASUREMENT SOLUTION TRIONet - the flexible measurement system for local or distributed measurements.

More information

PORTABLE SureHAND / DEWE-3210 series

PORTABLE SureHAND / DEWE-3210 series Automotive Energy & Power Analysis Aerospace Transportation General Test & Measurement SureHAND DEWE-3210 series Portable Data Acquisition Systems The extreme flexibility of the SureHAND series allows

More information

6220 Ethernet-Based Voltage Measurement Module

6220 Ethernet-Based Voltage Measurement Module 6220 Ethernet-Based Voltage Measurement Module Features 12 voltage inputs 16-bit, 100-kHz per channel sample rate ±10V input range Eight digital I/O Simultaneous sampling BNC connectors Multiple trigger

More information

CompuScope Ultra-fast waveform digitizer card for PCI bus. APPLICATIONS. We offer the widest range of

CompuScope Ultra-fast waveform digitizer card for PCI bus.   APPLICATIONS. We offer the widest range of We offer the widest range of high-speed and high-resolution digitizers available on the market CompuScope 1602 Ultra-fast waveform digitizer card for PCI bus today. Our powerful PC-based instrumentation

More information

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models

VIBBOX. 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels. Key Feature of Each VIBbox: Table 1. Key Features of VIBbox Models VIBBOX 32, 48, or 64-Channel Sound & Vibration Solution Expansion to 256 Channels VIBbox is a high-accuracy, high channel count, dynamic signal analyzer system for sound and vibration applications. Each

More information

Features Summary. Input Ranges

Features Summary. Input Ranges DT9844 32-Channel Analog Input USB DAQ Module Overview The DT9844 is a high-accuracy (20-bit resolution), high- speed (1 MS/s sample rate) USB data acquisition module offering unparalleled performance.

More information

LMS Pimento The Multichannel Analyzer with Portable Power

LMS Pimento The Multichannel Analyzer with Portable Power LMS Pimento The Multichannel Analyzer with Portable Power LMS INTERNATIONAL Empowering Engineering Innovation LMS Pimento The portable analyzer with professional power Looking for a solution for general

More information

DEWETRON Open System. Select your software to open a whole new world of possibilities

DEWETRON Open System. Select your software to open a whole new world of possibilities DEWETRON Open System Automotive Energy & Power Analysis Aerospace & Defense Transportation General Test & Measurement DEWETRON Open System Select your software to open a whole new world of possibilities

More information

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation

A variety of ECONseries modules provide economical yet flexible solutions. Waveform Generation ECONseries BUS: USB Type: Economy, Mini-Instruments ECONseries Economy USB Mini-Instruments Flexible Yet Economical A variety of low-cost ECONseries modules are available to provide flexible yet economical

More information

DT9828. Low-Cost, Isolated, Thermocouple Measurement Module. Overview. Key Features. Supported Operating Systems

DT9828. Low-Cost, Isolated, Thermocouple Measurement Module. Overview. Key Features. Supported Operating Systems DT9828 Low-Cost, Isolated, Thermocouple Measurement Module Overview The DT9828 is an 8-channel, isolated thermocouple DAQ module that features superb accuracy yet is lowcost and easy-to-use. The DT9828

More information

6224 Ethernet-Based Strain Measurement Module

6224 Ethernet-Based Strain Measurement Module Ethernet-Based Strain Measurement Module Features 12 strain gage inputs 24-bit/delta-sigma ADC per channel 50-kHz per channel sample rate User programmable excitation Simultaneous sampling Remote sensing

More information

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE Troubleshooting Ethernet Problems with Your Oscilloscope Introduction Ethernet is a family of frame-based computer networking technologies for local area networks (LANs), initially developed at Xerox PARC

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

NI Technical Symposium ni.com

NI Technical Symposium ni.com NI Technical Symposium 2016 1 New Hardware Technologies for DAQ Applications Nicholas Haripersad Field Sales Engineer Session Objectives Introduce the three major NI DAQ platforms Present future trends

More information

DT Channel Analog Input USB DAQ Module. Key Features:

DT Channel Analog Input USB DAQ Module. Key Features: DT9844 32-Channel Analog Input USB DAQ Module Ultra High-Accuracy: 20-bits, 0.01% Very High-Speed: 1 MHz sampling Low Noise, Low Crosstalk: -80dB @ 1kHz, 500kHz settling ±500V Tri-sectional Isolation:

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

High-Speed Data Acquisition System

High-Speed Data Acquisition System High-Speed Data Acquisition System 1 Quick & Easy Setup Easiest Data Acquisition Systems on the Market The TMX features a high resolution, 17" touch screen display, as well as pre-defined set up options,

More information

Digital Pre-emphasis Processor BERTScope DPP Series Datasheet

Digital Pre-emphasis Processor BERTScope DPP Series Datasheet Digital Pre-emphasis Processor BERTScope DPP Series Datasheet New microcontroller to provide more processing power RS-232 interface enhancement to speed up PCIe receiver equalization link training BERTScope

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Personal Daqs USB Data Acquisition Modules Models /55 & /56

Personal Daqs USB Data Acquisition Modules Models /55 & /56 USB Data Acquisition Modules Models /55 & /56 Features Multi-function data acquisition modules attach to PCs via Universal Serial Bus (USB) Ultra low-power design requires no external power or batteries

More information

Digital Pre-emphasis Processor BERTScope DPP Series Datasheet

Digital Pre-emphasis Processor BERTScope DPP Series Datasheet Digital Pre-emphasis Processor BERTScope DPP Series Datasheet Overview The DPP125C is a nonlinear signal conditioner capable of adding controllable amounts of pre-emphasis to a signal. It takes in single-ended

More information

VIBbox 64-Channel Sound & Vibration Solution

VIBbox 64-Channel Sound & Vibration Solution VIBbox 64-Channel Sound & Vibration Solution VIBbox is a high-accuracy, high channel count, dynamic signal analyzer system for sound and vibration applications. VIBbox packages four DT9857E modules in

More information

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit

Temperature measurement board, optically isolated, 16/8/4 channels for thermocouples, Pt100, RTD, 18-bit Temperature measurement board, optically isolated, 16/8/ channels for thermocouples, Pt100, RTD, 18-bit APCI-3200 Up to 16 channels for thermocouples or 8 inputs for resistance temperature detectors (RTD)

More information

±500 V Isolation Protects Your Data. Sample Rate. 16 bits ±1.25 V, ±2.5 V, ±5 V, ±10 V 100 ks/s 16 2

±500 V Isolation Protects Your Data. Sample Rate. 16 bits ±1.25 V, ±2.5 V, ±5 V, ±10 V 100 ks/s 16 2 DT9800 Series Isolated, Multifunction USB Data Acquisition Modules Overview The DT9800 Series is a family of low-cost, isolated, multifunction USB data acquisition modules. All DT9800 Series modules feature

More information

Agilent U2751A USB Modular Switch Matrix. Data Sheet

Agilent U2751A USB Modular Switch Matrix. Data Sheet Agilent U2751A USB Modular Switch Matrix Data Sheet Features and capabilities 32 two-wire crosspoints in 4x8 configuration Minimal crosstalk at up to 45 MHz Bandwidth of 45 MHz without the terminal block

More information

DT MS/s High-Speed, Isolated Simultaneous USB Data Acquisition Module. Overview. Key Features. Bandwidth of the DT9862

DT MS/s High-Speed, Isolated Simultaneous USB Data Acquisition Module. Overview. Key Features. Bandwidth of the DT9862 DT9862 10 MS/s High-Speed, Isolated Simultaneous USB Data Acquisition Module Overview The DT9862 is a high-speed, high-performance USB data acquisition module that provide throughput rates up to 10 MS/s

More information

Company Profile. Dewesoft Slovenia Head office, R&D and manufacturing. Dewesoft Austria Sales & marketing center

Company Profile. Dewesoft Slovenia Head office, R&D and manufacturing. Dewesoft Austria Sales & marketing center Company Profile Dewesoft handles complete instrument design, development, manufacturing, sales and marketing... ALL IN ONE HAND. Dewesoft was founded back in year 2000 and today Dewesoft products are being

More information

DT8824 High Stability, High Accuracy, Ethernet Instrument Module

DT8824 High Stability, High Accuracy, Ethernet Instrument Module DT8824 High Stability, High Accuracy, Ethernet Instrument Module The DT8824 Ethernet data acquisition (DAQ) module offers the highest stability and accuracy for measuring analog signals. Every signal input,

More information

6224 Ethernet-Based Strain Measurement Module

6224 Ethernet-Based Strain Measurement Module Ethernet-Based Strain Measurement Module Features 12 strain gage inputs 24-bit/delta-sigma ADC per channel 50 khz per channel sample rate User programmable excitation Simultaneous sampling Remote sensing

More information

DS-NET DS-NET. DEWESoft Measurement Innovation

DS-NET DS-NET. DEWESoft Measurement Innovation DS-NET DS-NET is a measurement and control system designed for many demanding applications, especially in the fields of Component Testing Engine Testing Process Performance Testing Structural Monitoring

More information

Ultra-Accurate Measurement for Temperature and Voltage

Ultra-Accurate Measurement for Temperature and Voltage Ultra-Accurate Measurement for Temperature and Voltage MEASURpoint is an ultra-accurate instrument for measuring any combination of thermocouple, RTD, and voltage inputs. MEASURpoint is available as a

More information

TraNET FE Data Acquisition Instrument

TraNET FE Data Acquisition Instrument TraNET FE Data Acquisition Instrument Datasheet The TraNET FE instrument turns your computer into a powerful Data Acquisition System Elsys AG Mellingerstrasse 12 CH-5443 Niederrohrdorf Switzerland Phone:

More information

Ultra-Accurate Temperature Measurement Instruments

Ultra-Accurate Temperature Measurement Instruments TEMPpoint Temperature Measurement Instruments Ultra-Accurate Temperature Measurement Instruments TEMPpoint is a series of precision temperature measurement instruments designed for high accuracy and industrial

More information

Keysight Technologies Faster Data Analysis with Graphical Digital Multimeter Measurements

Keysight Technologies Faster Data Analysis with Graphical Digital Multimeter Measurements Keysight Technologies Faster Data Analysis with Graphical Digital Multimeter Measurements Application Brief Test Challenges: Analyzing changes with time Identifying noise in your design 02 Keysight Faster

More information

Temperature Measurement Instruments Ultra-Accurate... by Design

Temperature Measurement Instruments Ultra-Accurate... by Design TEMPpoint Type: Temperature Measurement Instrument Temperature Measurement Instruments Ultra-Accurate... by Design TEMPpoint is a family of temperature measurement instruments designed for high accuracy

More information

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE

Troubleshooting Ethernet Problems with Your Oscilloscope APPLICATION NOTE Troubleshooting Ethernet Problems with Your Oscilloscope Introduction Ethernet is a family of frame-based computer networking technologies for local area networks (LANs), initially developed at Xerox PARC

More information

Agilent 66000A 1200 W DC Modular Power System, GPIB

Agilent 66000A 1200 W DC Modular Power System, GPIB Agilent 66000A 1200 W DC Modular Power System, GPIB Data Sheet Speed and accuracy for test optimization 8-slot mainframe accepts up to 8 DC power modules 1200 W total DC power output, up to 150 W per module

More information

Ultra-Accurate Measurement for Temperature and Voltage

Ultra-Accurate Measurement for Temperature and Voltage Ultra-Accurate Measurement for Temperature and Voltage MEASURpoint is an ultra-accurate instrument for measuring any combination of thermocouple, RTD, and voltage inputs. MEASURpoint is available as a

More information

A NEW DATA LOGGER Stand alone. Secure. Fast.

A NEW DATA LOGGER Stand alone. Secure. Fast. A NEW DATA LOGGER Stand alone. Secure. Fast. A data logger for profe Extensive functions LogMessage data loggers are universal. Whatever the application for slow or for high-speed acquisition Delphin has

More information

DT9837. High Performance USB Module for Sound & Vibration Analysis. DT9837 Features

DT9837. High Performance USB Module for Sound & Vibration Analysis. DT9837 Features DT9837 High Performance USB Module for Sound & Vibration nalysis DT9837 Features 4 simultaneous, 24-bit Delta-Sigma channels for high resolution measurements. Support for four IEPE inputs, including current

More information

Agilent 11713B/C Attenuator/Switch Driver

Agilent 11713B/C Attenuator/Switch Driver Agilent 11713B/C Attenuator/Switch Driver Technical Overview Automate ATE systems with Agilent 11713B/C attenuator/switch driver Add in a stand-alone driver for easy integration into new and exisiting

More information

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet

Agilent E36XXA Series Non-Programmable DC Power Supplies. Data Sheet Agilent E36XXA Series Non-Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Linear power supply Single, dual or triple output 10-turn voltage and current control Low noise and

More information

High-Performance Differential Probes P7350 P7330 P6330 Datasheet

High-Performance Differential Probes P7350 P7330 P6330 Datasheet High-Performance Differential Probes P7350 P7330 P6330 Datasheet Applications Communications (Gigabit Ethernet, Fibre Channel, InfiniBand) Semiconductor characterization and validation PCI Express Serial

More information

imc CRONOS-SL rugged autonomous mobile Sealed data acquisition system for harsh environments

imc CRONOS-SL rugged autonomous mobile Sealed data acquisition system for harsh environments imc CRONOS-SL rugged autonomous mobile Sealed data acquisition system for harsh environments imc productive testing Partner Italiano di imc dal 1993 Instrumentation Devices Srl Via Acquanera 29-22100 COMO

More information

A Step Into the Future of Data Measurement. Focus on Tests and Measurements. Let idaq Do the Rest.

A Step Into the Future of Data Measurement. Focus on Tests and Measurements. Let idaq Do the Rest. W H I T E P A P E R A Step Into the Future of Data Measurement Focus on Tests and Measurements. Let idaq Do the Rest. idaq Whitepaper OVERVIEW IDAQ, THE INTUITIVE, COMPLETE AND RELIABLE SOFTWARE FOR YOUR

More information

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

Electronic SUNSTAR & 传感与控制 Software   TEL: FAX: KiBox To Go Measurement and Ev Electronic SUNSTAR & 传感与控制 Software http://www.sensor-ic.com/ TEL:0755-83376549 KiBox To Go Measurement and Evaluation System for Combustion Analysis in Test Vehicles with KiBox Cockpit Software The KiBox

More information

The new Expert Logger 400: Industry 4.0 ready!

The new Expert Logger 400: Industry 4.0 ready! The new Expert Logger 400: Industry 4.0 ready! NEW AND ONLY WITH US: With an OPC UA interface! Data logging Test stand automation Process monitoring At last we have the security for measurement technology

More information

Keysight Technologies E3620A and E3630A Non-programmable DC Power Supplies. Data Sheet

Keysight Technologies E3620A and E3630A Non-programmable DC Power Supplies. Data Sheet Keysight Technologies and E3630A Non-programmable DC Power Supplies Data Sheet 02 Keysight and E3630A Non-programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Linear power supply

More information

SCP for Plastics Processing

SCP for Plastics Processing Measure & Analyze MCS SCP for Plastics Processing Modules for Signal Conditioning System Type 2853A..., 2207A..., 5063A..., 5227A..., 5613A... The SCP is a modular system for conditioning measuring signals

More information

Data Acquisition & Signal Conditioning Units

Data Acquisition & Signal Conditioning Units INNOVATION IN MAGNETICS DS2519/16 Data Acquisition & Signal Conditioning Units www.bartington.com Data Acquisition & Signal Conditioning Units Data Acquisition and Signal Conditioning Units Bartington

More information

Keysight Technologies

Keysight Technologies Keysight Technologies M9161D PXI Dual SP4T Solid State Switch Module 50 MHz to 20 GHz Data Sheet Introduction Description The Keysight Technologies, Inc. M9161D is a one slot PXI Dual SP4T solid state

More information

Precision Voltage Measurement. Instruments. Applications. Voltage Inputs. High-Stability, Low Drift Voltage References. Key Design Features

Precision Voltage Measurement. Instruments. Applications. Voltage Inputs. High-Stability, Low Drift Voltage References. Key Design Features VOLTpoint Precision Voltage Measurement Instruments Precision Voltage Measurement VOLTpoint is a family of precision instruments designed for measuring a wide range of voltage inputs; ideally suited for

More information

PCM 770 SYSTEM. for Signal Conditioning, Data Acquisition and PCM Encoding. Lancaster

PCM 770 SYSTEM. for Signal Conditioning, Data Acquisition and PCM Encoding. Lancaster Lancaster PCM 770 SYSTEM for Signal Conditioning, Data Acquisition and PCM Encoding 3061 Industry Drive, Lancaster, PA 17603 Tel 717-397-2777 Fax 717-397-7079 www.herley.com email:mrktng@herley.com Programmable

More information

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY! Telemetrie-Messtechnik Schnorrenberg User Manual CTP8-Rotate 8 (4) channel telemetry for rotating applications like wheels or rotors, high signal bandwidth, 16bit, software programmable INSTRUCTIONS FOR

More information

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

Wide Bandwidth Strain Gage Input 3B18 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM Wide Bandwidth Strain Gage Input 3B18 FEATURES Wideband (20 khz) single-channel signal conditioning module. Module Bandwidth is user-selectable between 20 khz and 100Hz, with user-supplied filter caps

More information

LabVIEW Basics I: Introduction Course

LabVIEW Basics I: Introduction Course www.ni.com/training LabVIEW Basics I Page 1 of 4 LabVIEW Basics I: Introduction Course Overview The LabVIEW Basics I course prepares you to develop test and measurement, data acquisition, instrument control,

More information

A variety of ECONseries modules provide economical yet flexible solutions

A variety of ECONseries modules provide economical yet flexible solutions Economy USB Mini-Instruments Flexible Yet Economical A variety of low-cost modules are available to provide flexible yet economical solutions. Choose the number of analog I/O and digital I/O channels,

More information

Keysight Technologies RS232/UART Protocol Triggering and Decode for Infiniium Series Oscilloscopes. Data Sheet

Keysight Technologies RS232/UART Protocol Triggering and Decode for Infiniium Series Oscilloscopes. Data Sheet Keysight Technologies RS232/UART Protocol Triggering and Decode for Infiniium 90000 Series Oscilloscopes Data Sheet This application is available in the following license variations. Order N5462A for a

More information

DRTS 66 can test all the following relays

DRTS 66 can test all the following relays Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual control with color display Simultaneously available: 6 Current and 6 Voltage plus 1 battery simulator outputs

More information

Keysight U2751A USB Modular Switch Matrix

Keysight U2751A USB Modular Switch Matrix Keysight U2751A USB Modular Switch Matrix The Keysight Technologies, Inc. U2751A USB modular switch matrix offers a high quality, low-cost switching solution for automated testing. It has 32 two-wire cross

More information

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet

Agilent E363xA Series Programmable DC Power Supplies. Data Sheet Agilent E363xA Series Programmable DC Power Supplies Data Sheet Reliable Power, Repeatable Results Single and triple output 80 W to 200 W output power Dual range output Low noise and excellent regulation

More information

CTRL7100A CTRL7100A Instrument Controller

CTRL7100A CTRL7100A Instrument Controller CTRL7100A CTRL7100A Instrument Controller Streaming capture to internal RAID of over 2 hours at full 800 MHz bandwidth enables environment recording and analysis of long event sequences SignalVu-PC and

More information

Chapter 1 Introducing the OM-USB Functional block diagram... 5

Chapter 1 Introducing the OM-USB Functional block diagram... 5 Table of Contents Preface About this User's Guide... 4 What you will learn from this user's guide... 4 Conventions in this user's guide... 4 Where to find more information... 4 Safety guidelines... 4 Chapter

More information

Computerized Measurement systems

Computerized Measurement systems Elektrisk Mätteknik, LTH Computerized Measurement systems 1. Introduction to Computerized measurements systems By Tomas Jansson, some text excerpts from NI application note AN007 regarding signal conditioning,

More information

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope

DM3100 Solutions. Application-specific Portable Data Capture Systems built on the DM3100 Data Platform. PC-based Data Logger. Digital Oscilloscope 3100 Application-specific Portable Data Capture Systems built on the 3100 Data Platform PC Measurement Digital Oscilloscope PC-based Data Logger Data Recorder & Logger Made Easy! Style! Fast & Furious

More information

Sefram SEFRAM DAS 20/DAS 40. Sefram

Sefram SEFRAM DAS 20/DAS 40. Sefram Make sure to visit our Website http://www.sefram.fr Sefram Sefram SEFRAM DAS 20/DAS 40 2 to 4 analogue channels Universal input DC, AC+DC RMS voltage measurement Frequency, Thermocouple Power analysis

More information

Analog Input Sample Rate

Analog Input Sample Rate ECONseries Low Cost USB Data Acquisition Modules Overview The ECONseries is a flexible yet economical series of multifunction DAQ modules. You chse the number of analog I/O and digital I/O channels, the

More information

INNOVATION IN MAGNETICS DS-2201/8 DAS1. Data Acquisition System.

INNOVATION IN MAGNETICS DS-2201/8 DAS1. Data Acquisition System. INNOVATION IN MAGNETICS DS-2201/8 DAS1 Data Acquisition System www.bartington.com DAS1 Data Acquisition System DAS1 Data Acquisition System The DAS1 is a multi-sensor data acquisition system designed to

More information

Overview DT Measure Foundry is a drag-anddrop test and measurement application builder designed to give you top performance

Overview DT Measure Foundry is a drag-anddrop test and measurement application builder designed to give you top performance DT Measure Foundry DT Measure Foundry 3.0 Test and Measurement Application Builder Software Key Features Easy-to-use, affordable measurement software. New approach to measurement no programming, no wiring:

More information

PRODUCT DATA. PULSE Vibration Check Systems for Aircraft Engines Types 3647-A, 3647-B including PULSE Standard Configuration 3560-B-T57

PRODUCT DATA. PULSE Vibration Check Systems for Aircraft Engines Types 3647-A, 3647-B including PULSE Standard Configuration 3560-B-T57 PRODUCT DATA PULSE Vibration Check Systems for Aircraft Engines Types 3647-A, 3647-B including PULSE Standard Configuration 3560-B-T57 To ensure the maintenance of helicopter engines and to optimise the

More information

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A... Electronics & Software Kistler LabAmp Charge Amplifier and Data Acquisition Unit for Dynamic Measurements This universal laboratory charge amplifier can be used wherever dynamic signals 1) of mechanical

More information

16-Bit A/D Converter (ENOB=14.1) 16-bit D/A. 16-bit D/A. Digital I/O (8/8) Counter/Timer (2)

16-Bit A/D Converter (ENOB=14.1) 16-bit D/A. 16-bit D/A. Digital I/O (8/8) Counter/Timer (2) DT9818 Isolated, Embedded USB Data Acquisition Board The DT9818 is perfect for embedding in a custom application where isolation is required. The DT9818 is a highperformance USB data acquisition (DAQ)

More information

high performance signal conditioner cards

high performance signal conditioner cards Configure multiple sensor interface with Endevco s OASIS 2000 providing maximum flexibility with assorted high performance signal conditioner cards and seamlessly integrated using Windows -based controlling

More information

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A...

DynoWare. Electronics & Software. Software for Data Acquisition and Evaluation. Type 2825A... Electronics & Software DynoWare Software for Data Acquisition and Evaluation 2825A... Kistler DynoWare is a universal and easy to use software, which is particularly suitable for force measurements with

More information

DS-IMU NEXT GENERATION OF NAVIGATION INSTRUMENTS

DS-IMU NEXT GENERATION OF NAVIGATION INSTRUMENTS DS-IMU NEXT GENERATION OF NAVIGATION Ruggedized and reliable GPS aided inertial navigation system including AHRS that provides accurate position, velocity, acceleration and orientation under most demanding

More information

Electrical Clock Recovery Modules

Electrical Clock Recovery Modules Electrical Clock Recovery Modules / Modules for DSA8200* 1 Series Oscilloscopes Data Sheet Features & Benefits Electrical Clock Recovery for: Enumerated Bit Rates between 50 Mb/s and 12.6 Gb/s Continuously

More information

Advanced NI-DAQmx Programming Techniques with LabVIEW

Advanced NI-DAQmx Programming Techniques with LabVIEW Advanced NI-DAQmx Programming Techniques with LabVIEW Agenda Understanding Your Hardware Data Acquisition Systems Data Acquisition Device Subsystems Advanced Programming with NI-DAQmx Understanding Your

More information

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels

DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) FALCON Models TA220-1000 Series DATA ACQUISITION SYSTEMS Stand-alone & with Recorder Portable, 1 to 16 Channels The

More information

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles Electronics & Software KiBox To Go Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles Type 2893A... with KiBox Cockpit Software The KiBox is a complete combustion

More information

Differential Probes TDP1500 TDP3500 Data Sheet

Differential Probes TDP1500 TDP3500 Data Sheet Differential Probes TDP1500 TDP3500 Data Sheet Features & Benefits Outstanding Electrical Performance 3.5 GHz and 1.5 GHz Bandwidth Models Accurate Measurements for Serial and Digital Applications Excellent

More information

ThinkRF R5500. Real-Time Spectrum Analyzer 9 khz to 8 GHz / 18 GHz / 27 GHz. Technical Data Sheet Preliminary

ThinkRF R5500. Real-Time Spectrum Analyzer 9 khz to 8 GHz / 18 GHz / 27 GHz. Technical Data Sheet Preliminary Technical Data Sheet Preliminary ThinkRF R5500 Real-Time Spectrum Analyzer 9 khz to 8 GHz / 18 GHz / 27 GHz Featuring Real-Time Bandwidth (RTBW) up to 100 MHz Spurious Free Dynamic Range (SFDR) up to 100

More information

DI-788 Data Acquistion System

DI-788 Data Acquistion System Accepts Fully Isolated DI-8B Style Plug-In Amplifiers 32 Analog Input Channels Ethernet Interface 14-Bit Resolution Up to 180KHz Sample Throughput Rate DATAQ Instruments announces model DI-788, a new 32-channel

More information

Features. RoHS COMPLIANT 2002/95/EC

Features. RoHS COMPLIANT 2002/95/EC PCIE-1730 32-ch TTL and 32-ch Isolated Digital I/O PCI Express Card 32-ch isolated DI/O (16-ch digital input, 16-ch digital output) 32-ch TTL DI/O (16-ch digital input,16-ch digital output) High output

More information

DaqBoard/1000. Series 16-Bit, 200-kHz PCI Data Acquisition Boards

DaqBoard/1000. Series 16-Bit, 200-kHz PCI Data Acquisition Boards 16-Bit, 200-kHz PCI Data Acquisition Boards Features 16-bit, 200-kHz A/D converter 8 differential or 16 single-ended analog inputs (software selectable per channel) Up to four boards can be installed into

More information

FP-PS-4. Features. Installation

FP-PS-4. Features. Installation OPERATING INSTRUCTIONS FP-PS-4 FieldPoint Power Supply These operating instructions describe the installation, features, and characteristics of the FP-PS-4. Features The FP-PS-4 is a FieldPoint power supply

More information

New Technologies in Data Acquisition

New Technologies in Data Acquisition New Technologies in Data Acquisition Agenda Introduction to PC Based Data Acquisition New Technologies in Data Acquisition 1. New Bus Technologies 2. Signal Conditioning, Timing and Synchronization Introduction

More information

PRODUCT DATA. Intelligent Data Acquisition System Type 3561

PRODUCT DATA. Intelligent Data Acquisition System Type 3561 PRODUCT DATA telligent Data Acquisition System Type 3561 telligent Data Acquisition System Type 3561 is a modular data acquisition frontend, for use with application software packages such as Spatial Transformation

More information

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications

Fluke 8845A/8846A Digital Multimeters. Precision and versatility for bench or systems applications Fluke 8845A/8846A Digital Multimeters Precision and versatility for bench or systems applications 3 Exceed your expectations for performance and value With 14 measurement functions, math and analysis modes,

More information

6640A Series Single-Output, 200 W DC Power Supplies, GPIB

6640A Series Single-Output, 200 W DC Power Supplies, GPIB 6640A Series Single-Output, 200 W DC Power Supplies, GPIB Data Sheet Speed and accuracy for test optimization Fast, low-noise outputs Analog control of output voltage and current Fan-speed control to minimize

More information