SCOOP STUDIO. User Manual

Size: px
Start display at page:

Download "SCOOP STUDIO. User Manual"

Transcription

1 SCOOP STUDIO User Manual AETA AUDIO 361, avenue du Général de Gaulle Clamart FRANCE Tel. +33 (0) Fax +33 (0) Telex Web : Ed. A SCOOP STUDIO - User Manual L.A.F.

2

3 Table of contents 1. SCOOP STUDIO Easy quick Start Introduction Functions Applications Setting up the SCOOP STUDIO Power Connection to the ISDN Connection to the POTS SCOOP STUDIO STRUCTURE Front view Scoop Studio status General synoptic diagram Audio section Encoding and decoding Audio Interfaces Audio performance Audio monitoring SCOOP STUDIO OPERATION: How it works Introduction User interface Scoop Studio Menu How to Set-Up Profiles on the Scoop Studio What is a profile? How to manage profiles on the Scoop Studio Connecting 2 SCOOP STUDIO Initiating a call Disconnecting a call Auto Answering Entering local Numbers Entering SPID Numbers ( USA ) Ed. A SCOOP STUDIO - User Manual L.A.F.

4 9. POTS Information Factory default configuration POTS modes Network parameters Error protection Troubleshooting Tests Audio section testing Network test ISDN modem information ISDN Protocols ISDN CLEARING CAUSES How to open a SCOOP STUDIO ready for servicing Connectors layout Remote Connector POTS Interface ISDN Interface Network External DC connector Environment...39 SCOOP STUDIO User Manuel Ed. A

5 1. SCOOP STUDIO Easy quick Start 1. Plug ISDN or POTS line to the appropriate socket on rear of unit 2. Plug in audio connections. 3. Power on the Scoop Studio via switch On/Off on rear panel of unit. 4. Select the appropriate network via the network menu 5. - To use direct dial Number mode, enter a number - To dial one of 5 last numbers press green phone key once. - To use a profile number, enter a letter For 2 last modes, select the profile number via keypad (left and right key) 6. Press green phone key again for dialling. 7. If busy or bad connection Press "ESC" then press the green phone key twice to redial the last number dialled. 8. Connection status will be displayed in LCD screen once connected Ed. A SCOOP STUDIO - User Manual 1

6 2. Introduction 2.1. Functions The Scoop Studio is designed to enable radio broadcasters to conduct high quality live two-way remote broadcasts, or two way commentaries with return cue, via ISDN or POTS lines Algorithms The Scoop Studio contains a mono audio compressor/de-compressor (Codec) that performs all necessary ISDN and POTS algorithms. In ISDN mode, the user can select one of four operational audio standards: 1. Phone mode (G.711, 3,5kHz) 2. Live speech ( G.722, 7kHz, low delay ) 3. Music CD quality (Layer II, 20kHz) 2 4. Live concert (4SB-ADPCM,15kHz, proprietary low delay ) 2 In POTS mode, the user has only live speech mode ( CELP, 7kHz ) Audio interfaces The Scoop Studio contains one audio input, one audio output and one headphone for monitoring Transmission Using an ISDN line, transmission bit-rate is either 64kbps or 128kbps 2. Using a POTS line, transmission bit rate depends on the telecommunication network quality with a maximum bit-rate of 33.6 kbps. The Scoop Studio transmits data at a minimum rate of bits and at a maximum of bits of information a second The Scoop Studio can work in many countries using various ISDN standards. As ISDN protocol may vary from country to country, consult your AETA dealer before carrying your Scoop Studio abroad. 1 Depending on configuration version 2 On the 15kHz ISDN version 2 SCOOP STUDIO - User Manual Ed. A

7 2.2. Applications News remotes. Live sport commentaries with local contributors. Remote two-way interviews. Remote contributions into studio discussions. Live music concerts Ed. A SCOOP STUDIO - User Manual 3

8 3. Setting up the SCOOP STUDIO 3.1. Power Optional DC supply The Scoop Studio will also work on any external 8 to 15-volts DC source. A typical source will be a car cigarette adapter. Connect your DC power cord to the socket at the back panel of the unit ( labeled DC In 8-15 V 2A), and plug the other end into your DC power source. Note : See the chapter 14 for the connection Connection to the ISDN Connect the (RJ45) connector of the ISDN cable into the socket on the back panel marked "ISDN", and connect the other end of the cable into the ISDN wall socket. The ISDN modem of the scoop is a S/T or a U interface depending on the unit type. You can select the correct ISDN protocol for a given country from the menu. Given the various kinds of ISDN protocols used in different countries or inside PBXs, ISDN compatibility problems may occur. Please be sure to select the right protocol for the country you are in. In case oftrouble please contact your AETA dealer for advice Connection to the POTS Connect the (RJ11) connector of the telephone cable into the socket on the back panel marked "ANALOG", and then connect the other end of the cable into the telephone wall socket. The Scoop Studio's RJ11 connector will accept 4 or 6 conductor modular plug, but only the 2 center conductors, ( typically Red & Green ) are used. 4 SCOOP STUDIO - User Manual Ed. A

9 Caution: Every country has its own style of telephone connector. Consult your engineers, your local AETA dealer for further advice. Dialing methods Telephones dial numbers either by pulsing the line, (you will hear a "clicking" sound similar to that heard when dialing from a rotary dial telephone) or by sending audio tones ( DTMF ) The Scoop Studio can dial using either pulse or DTMF tones. Caution: Do not connect the Scoop Studio to a telephone jack that provides power for lighting a telephone's dial. Do not connect the Scoop Studio to a party line or coin-operated telephone line. Not suitable as an extension to a pay phone or use with a shared service line or 1+1 carrier system line. You should disable call waiting if in use. PBX and PABX applications The internal modem of the Scoop Studio is only approved for use as an extension instrument to compatible PBXs. Contact AETA AUDIO S.A. or your local dealer for an up-to-date list of PBXs with which the internal modem is compatible. AETA AUDIO S.A can not guarantee that the Scoop Studio will operate correctly under all possible conditions of connections to compatible PBXs. Any cases of difficulty should be referred in the first instance to AETA AUDIO S.A Ed. A SCOOP STUDIO - User Manual 5

10 4.1. Front view 4. SCOOP STUDIO STRUCTURE Figure 1 - Front panel 1 - LCD display 5 Bargraph 2 - Function keys 6 Monitoring selection 3 - Status LED s 7 Headphone socket 4 Keypad 8 - Headphone volume adjustment 4.2. Scoop Studio status There are 28 LED s on the front panel providing the following information : - Info ( 2 yellow LED s ) : Information ( Future use ). - Alarm (red) : When on, indicates a network problem. - Dec (green) : When "on" indicates that a successful connection exists and the Scoop Studio is decoding the POTS or ISDN signal. - Tx Level meter : 11 LED s ( scale 20 to + 5 VU ) + an Overload led - Rx Level meter : 11 LED s ( scale 20 to + 5 VU ) + an Overload led 6 SCOOP STUDIO - User Manual Ed. A

11 4.3. General synoptic diagram DSP board LCD Interfaces board Optional DC Board Motherboard Microprocessor board Power board Monitoring Board Figure 2 Scoop Studio synoptic Ed. A SCOOP STUDIO - User Manual 7

12 5.1. Encoding and decoding 5. Audio section Scoop Studio use includes a wide range of coding algorithms. First, one can select among algorithms compliant with ISO and ITU-T 1 recommendations : G711; ITU-T G722 (mono at 64 kbit/s); MPEG Audio Layer II at 48, 32, 24 or 16 khz, with programmable channel mode and bit rate ; MPEG Audio and G722 algorithms comply with ITU-T J52 recommendation for ISDN transmission. Besides, other algorithms are available, that are so-called proprietary because they do not comply with enforced standards : Proprietary MPEG Layer II at 64 kbit/s or 128 kbit/s (for compatibility with ISDN codecs that are not compliant with the J52 recommendation) ; 4SB ADPCM, running in mono at a 128 kbit/s bit rate; the bandwidth with this algorithm is 15 khz ; TDAC mono, running at 64 kbit/s, with a 15 khz bandwidth ; available as an option. The following describes some important features of the various available algorithms and protocols Notes about G711 G711 is the standard coding used for voice transmission on public telephone networks. This algorithm is used for links (via ISDN) with telephones or hybrid devices. 1 former CCITT 8 SCOOP STUDIO - User Manual Ed. A

13 Notes about G722 With G722 coding, two synchronisation modes are available: Statistical recovery byte synchronisation method (alias SRT) ; H242 synchronisation; in this case, 1.6 kbit/s from the compressed data are used for this. H242 synchronisation is highly recommended when possible, as it features higher reliability and faster recovery time, while degradation (because of the bit rate used for framing) is minimal. This is recommended practice according to J Notes about J52 and MPEG coding The ITU-T J52 recommendation was defined in order to allow the interoperability of various equipment over the ISDN 1, using common coding standards. It includes the following features: Interoperation procedures as per ITU-T H242 recommendation ; In the case of MPEG encoding, optional protection against transmission errors (Reed-Solomon error correction codes). It must be noted that, thanks to the interoperation protocol, J52 codecs, when setting up a link, can negotiate automatically and agree on a configuration that is compatible with the capability of both units (regarding bit rate, channel mode, etc.). In this way, when the units differ in their capability (or make), the resulting configuration may be different from expected beforehand, but in most cases the link will work and audio will be transmitted. As another useful consequence, this also gives users more tolerance to mistakes when configuring the units on the two sides of the transmission links, as the codecs will adapt automatically even with differences in the initial settings of the two units. 1 J52 is not needed nor applicable to leased line connections Ed. A SCOOP STUDIO - User Manual 9

14 Notes about TDAC As an option, the codec can also include the TDAC algorithm. TDAC is for Time Domain Aliasing Cancellation ; this is a transform coding based on an MDCT (Modified Discrete Cosine Transform), encoding a 15 khz bandwidth mono signal at a 64 kbit/s bit rate. When the option is installed, three modes are available : TDAC mono full-duplex, running at 64 kbit/s, with a 15 khz bandwidth ; G722/TDAC : G722 encoding, TDAC decoding, running both in mono at 64 kbit/s ; TDAC/G722 : TDAC encoding, G722 decoding (with SRT), running both in mono at 64 kbit/s ; this mode is symmetric to the previous one Symmetric or asymmetric codec modes The codec allows two communication modes: Symmetric communication: in this mode, the encoder and decoder both use the same coding algorithm with the same configuration (channel mode, etc.). In this case, the communication is strictly symmetric full-duplex, with exactly the same coding configuration used in both directions (local to remote and remote to local). This is usually required when using proprietary algorithms. Asymmetric communication: this mode is used for applications requiring different coding configurations in the two directions. The J52 protocol allows such mode. To give some examples, it is possible to transmit MPEG in one direction and G722 in the other one. With the TDAC option, asymmetric modes are also available wherein one direction is G722 coded while the other one is TDAC coded. Such mode is useful e.g. in order to get a low delay return path encoded in G722 while the send path is encoded with higher quality but a higher delay. 10 SCOOP STUDIO - User Manual Ed. A

15 5.2. Audio Interfaces Analogue audio Input Audio characteristic are measured over a 20 to 20kHz bandwidth except when diffently stated. Format balanced Connector 3-pin female XLR socket Maximum input level +0 to +22 dbu by step pf 1dB ( menu ) Input impedance 10 kω Common mode rejection ratio 1kHz Table 1 Input interface analogue audio Outputs The audio signal output is available on the line level output. The monitoring source can be changed with the headphone key. - If the led in the extension of the Tx bargraph is light, you have the local audio signal on the headphone. - If the led in the extension of the Rx bargraph is light, you have the return audio signal on the headphone. - If the same both leds are light, you have the local audio signal on the left ear and the return on the right ear. Line Out Interface : Format Balanced Connector 3-pin male XLR socket Maximum output level +0dBu to +22dBu by steps of 1dB ( software selection ) Output impedance Output symmetry 50 Ω > 60 db Ed. A SCOOP STUDIO - User Manual 11

16 Headphone Interface : Connector Maximum output level Load impedance 6.35mm jack socket +20dBu 16 Ω 5.3. Audio performance A ) Analog performance Measurement condition: - AD/DA Loop - Sample frequency : 48kHz Maximum Gain ( Input to Output ) +22dB Signal to Noise ratio 84dBrms Bandwidth 20Hz Hz ± 0.5dB Distortion ( THD+N) < 80 db 950Hz Table 2 Audio performance B) In ISDN mode Data rate Sample frequency Bandwidth Algorithm 128 kbit/s 16/24/32/48kHz 20Hz - 20kHz MPEG II J kbit/s 16/24/32/48kHz 20Hz - 15kHz MPEG II 128 kbit/s 32kHz 20Hz - 15 khz 4S/B 64 kbit/s 24kHz 20Hz kHz MPEG II J52 64 kbit/s 24kHz 20Hz kHz MPEG II 64 kbit/s 48kHz 20Hz - 8.2kHz MPEG II 64 kbit/s 16kHz 20Hz - 7kHz G722 SRT/H kbit/s 16kHz 300Hz - 3.5kHz G711- phone 64 kbit/s 32kHZ 20Hz 15kHz TDAC Table 3 ISDN mode 12 SCOOP STUDIO - User Manual Ed. A

17 Note : In MPEG II without J52, Scoop Studio is compatible with other manufacturer codecs. C) POTS mode - CELP Algorithm Data rate Audio quality Bandwidth : 40 Hz to 7 khz (@ 24 kbps data rate) 12Kbit/s 3.6kHz 24 kbit/s can typically be achieved in all countries 14.4Kbit/s 4.3kHz that support V.34 modems on their public 16.8Kbit/s 5.1 khz switched networks Kbit/s 5.7 khz Higher rate depends on line quality Kbit/s 6.3 khz The CELP algorithm is optimised running at Kbit/s 7.2 khz kbit/s. Table 4 CELP Note : CELP is a proprietary algorithm of France Telecom CNET 5.4. Audio monitoring The 12 LED's labeled Tx on the front side of the Scoop Studio indicate the peak level of the sending audio signal. The level display reference (0 db) is 8 db below the clipping level. The 12 LED's labeled Rx on the front side of the Scoop Studio indicate the peak level of the receiving audio signal. The level display reference (0 db) is 8 db below the clipping level Ed. A SCOOP STUDIO - User Manual 13

18 6. SCOOP STUDIO OPERATION: How it works Introduction Incoming audio into the Scoop Studio is digitized by a state-of-the-art A/D converter and processed through the Scoop Studio's codec. The data is then sent via the internal ISDN or POTS synchronous modem to the telephone network ( ISDN or POTS ) to a remote Scoop Studio or another compatible ISDN Audio Codec. Operating with a very fast DSP, the codec runs an algorithm modeling the digital audio signal, in order to reduce the digitized audio data rate. At the other end of the telephone network, the answering Scoop Studio reconstructs the original audio signal with very little loss or induced artefacts and at an extremely low audio delay time User interface The user interface consists of a lexan matrix keypad and a LCD display. The keypad has two sections. - The first section is a 4x3 matrix including the numbers from 0 to 9, *, #. Some keys have many functions : 2, 3, 4, 5, 6, 7, 8, 9, 0: for accessing to letters display on the key, press the key several times. Note : Space character is available on the 1 key. - The second section is the Extended Keypad functions under the display. There are 3 function keys not labeled. The key function depends of the menu, the function label appears over the key on the second line of the display - The third section is the special Keypad functions. OK key to validate a choice. Esc key to escape from a menu. Green phone key to make a call. Red phone key to on hook a call. 14 SCOOP STUDIO - User Manual Ed. A

19 6.3. Scoop Studio Menu 1) Main menu TOOLS SETUP To scroll in the sub-menus use the keys under the word If a second sub-menu exists, you can enter by pressing again the key under the word At any time you can return to the main menu by pressing the Esc key. Note : the symbol between TOOLS and SETUP means : DIRECTORY If you press green phone key, you access to the 5 last called number. If you enter a letter, you access to the remote directory. If you enter a number, you can make a direct call. Note : If you have a restricted menu, you can disable it by pressing the directory key and this following sequence: 1, 6, 4, Scoop Studio default configuration The Scoop Studio's General reset set default configuration is useful to configure the modem in case communication difficulties are encountered. Note : The stored calling numbers are not erased when you make a General reset Ed. A SCOOP STUDIO - User Manual 15

20 Menu 1 NETWORK ANALOG ISDN TOOLS SETUP TOOLS TOOLS TOOLS DIRECTORY SETUP ISDN Or SETUP ANALOG Misc Status Maintenance Remote Local Net Audio Cod Net Audio Cod Menu 2 Menu 3 Menu 4 MAINTENANCE Tests MAINTENANCE MAINTENANCE Download About MAINTENANCE U.access LOOP2-network OK None Loop2-network Loop3-codec AD/DA Analog loop Test tone Coding test ABOUT Micro : V1.00 Micro : V1.00 Cod : V4.00 Dec : V4.00 Xilinx : V1.01 O : SSGW USER ACCESS Full Reduced CURRENT CONFIG PMPEG L2 24K 1B MISC General reset MISC LCD contrast MISC Language MISC Keyboard lock GENERAL RESET CONFIRM : OK LCD CONTRAST English OK English French KEYBOARD LOCK Off On 16 SCOOP STUDIO - User Manual Ed. A

21 Menu 1 Menu 2 DIRECTORY Remote Local REMOTE PROFILES REMOTE PROFILES REMOTE PROFILES Load Delete Edit N>Name N>Name N>Name Delete LOCAL SETUP Load LOCAL SETUP Save as LOCAL SETUP Delete N>Name >Name_ N>Name Load Replace Delete REMOTE PROFILES New NETWORK : ISDN NETWORK : ANALOG ToAnalog OK ToISDN OK ASSOCIATED COD Current >Name_ Replace Current None >Number 1 Replace >Number 2 Replace Ed. A SCOOP STUDIO - User Manual 17

22 Menu 1 Menu 4 NETWORK : ISDN ToAnalog Param PARAMETERS Protocol Australia OK For S interface For U interface Australia Belgium Euro ISDN France VN2 France Vn3 France Vn6 Germany 1TR6 Japan NTT Japan KDD Nortel DMS NI-2 AT&T 5E10 Net SETUP ISDN Audio Cod Menu 3 PARAMETERS Address ADDRESS ADDRESS ADDRESS ADDRESS Local number1 Local number2 Sub-Address 1 Sub-Address 2 SPID 1 SPID 2 LDN 1 LDN 2 >_ >_ >_ >_ Replace Replace Replace Replace PMPEG L2 24K 1B OK PMEG L2 24K 1B G722 SRT 4SB ADPCM 2B Other CODING ALGORITHM P-MPEG L2 MPEG L2 J52 P-MPEG L2 G711 (phone) G722 SRT G722 H242 4SB ADPCM TDAC SAMPLING RATE 48 khz BIT RATE 64 kb/s (1B) 48 khz 32 khz 24 khz 16 khz 64 kb/s (1B) 128 kb/s (2B) ERROR CORRECTION Mode 0 Mode 0 Mode 1 Mode 2 Mode 3 AUDIO AUDIO Max Output lvl Max Input lvl +2dBu +22dBu OK OK 18 SCOOP STUDIO - User Manual Ed. A

23 Menu 3 Menu 1 SETUP ANALOG Net Audio Cod NETWORK : ANALOG ToISDN Param PARAMETERS Dialing method PARAMETERS PARAMETERS PARAMETERS PARAMETERS Dial tone Clock mode Analog mode Ligne level DIALING METHOD DIAL TONE CLOCK MODE ANALOG MODE -10dBm Tone Pulse Detect Undetect Standard Free Codec Hybrid OK 0dBm -3dBm -6dBm -9dBm -10dBm -16dBm AUTO 24Kb/s P0 OK AUTO 24Kb/s P0 AUTO 12Kb/s P1 FIX 16.8Kb/s P2 Other AUDIO AUDIO Max Output lvl Max Input lvl +2dBu +22dBu OK OK Menu 4 MAX LINE SPEED 24 Kb/s 24 Kb/s 21.6 Kb/s 19.2 Kb/s 16.8 Kb/s 14.4 Kb/s 12 Kb/s Auto SPEED Fixed SECURED MODE P0 P1 P Ed. A SCOOP STUDIO - User Manual 19

24 7. How to Set-Up Profiles on the Scoop Studio You can access and edit memory locations and Profiles directly from the front panel keypad and menus of the Scoop Studio. The Scoop Studio has the ability to allow you to pre-program the 100 Profile locations What is a profile? A profile is a non-volatile, pre-programmed memory location stored within the Scoop Studio which functions very similar to the auto dial memory locations on an average telephone. A remote profile can contain an ISDN or POTS number with specific parameters associated with that number. The remote profile can contain the name of the location to be dialled and its specific algorithm. You can create up to 50 unique remote profiles on the Scoop Studio. If the remote profile is an ISDN type, you can have two numbers stored ( one number for each B channel ). A local profile ( named local setup for making the difference ) can contain ISDN or POTS local parameters. The local setup can contain the name and all network parameters like local address in ISDN. You can create up to 50 local setups on the Scoop Studio 7.2. How to manage profiles on the Scoop Studio Note: All remote profile can be a POTS profile or an ISDN profile How to manage remote Profiles From the Main Function Menu, select DIRECTORY symbol, and press the key under it. After having selected REMOTE choice, you can select different actions : - Load for loading in memory a profile. 20 SCOOP STUDIO - User Manual Ed. A

25 - Delete for deleting a profile. - Edit for looking each elements of the profile. - New for creating a new profile. Load With the left and right extended display key, you can scroll the remote profiles. If you enter a letter on the keypad, the profile list scroll to the profile whose the name begin with this letter. With the centre extended display key, you scroll each profile items. For calling with the display profile, you have just to press the green phone key. For loading in memory the profiles, press the OK key. Delete With the left and right extended display key, you can scroll the remote profiles. If you enter a letter on the keypad, the profile list scroll to the profile whose the name begin with this letter. With the centre extended display key, you delete the display profile Edit With the left and right extended display key, you can scroll the remote profiles. If you enter a letter on the keypad, the profile list scroll to the profile whose the name begin with this letter. With the centre extended display key, you scroll each profile items. Press OK key to modify one or many items of the display profile. New At first you should select the network : Analogue/POTS or ISDN. After that, you have the choice to associate an algorithm ( current algorithm configuration) or not to your profile. If you don t associate an algorithm to your profile, Ed. A SCOOP STUDIO - User Manual 21

26 when you will make a call with this profile, Scoop Studio will use the current algorithm configuration. The next stage is to enter a name for your profile, and press OK to valid. Now, Scoop Studio ask the user to enter one or two numbers ( depend of algorithm configuration ). If you don t enter numbers, when you will make a call with this profile, Scoop Studio will ask you to enter the numbers How to manage local setups From the Main Function Menu, select DIRECTORY symbol, and press the key under it. After having selected LOCAL choice, you can select different actions : - Load for loading in memory a local setup. - Save as for creating a new local setup. - Delete for deleting a local setup. In a local setup memory we save the current network configuration. For example : If you are in ISDN, we save the ISDN protocol, the local address and the local sub-address. 22 SCOOP STUDIO - User Manual Ed. A

27 8. Connecting 2 SCOOP STUDIO. Note: The following is valid for both POTS and ISDN mode. Warning: In ISDN mode with some PBX s, you must enter your local number and your SPID number prior making a call Initiating a call There are 3 ways to initiate a call : Dialing with a profile Direct Dialing Re-dialing the previous number Dialling Using a Profile Number From the Main Function Menu, select DIRECTORY symbol, and press the key under it. After having selected REMOTE choice, press the key under Load. Note : You arrive directly in the remote profile list, when you enter a letter under the main menu. Select the profile number and press Green phone key. "Call XXXXXXXX" appears on the screen and is dialed automatically Direct Dialling Enter the telephone number and press the green phone key. If you call two numbers ( In ISDN ), you need to press again the same key Ed. A SCOOP STUDIO - User Manual 23

28 Note : In the case that you have 2 numbers, if you don t enter the second number, we call twice the first number. A message to indicate that the call is in progress is displayed on the screen. Note : - The number length is limited to 23 digits and may be displayed on 2 lines. - Insert a * between number and sub-number in ISDN mode. - Insert a * for wait in POTS mode Re-Dialling the Previous Number From the main menu, press green phone key, The last called number appears on the screen, press again the green phone key. Actually, your are in a short list of the five last called numbers. "Call in progress" along with the redialed number is displayed on the screen. Note : We don t re-load configuration, we use the last configuration used ( current now). Note : In case of mistake you may come back at the beginning of the menu by pressing the "Esc" key. Note : As soon as the local and remote Scoop Studio are connected, the CONNECT result code is displayed. If a connection can not be established, the NO CARRIER result code will be displayed. The bit rate is displayed in POTS mode. 24 SCOOP STUDIO - User Manual Ed. A

29 8.2. Disconnecting a call To end a call press the "red phone" key. "Wait..." is displayed, after awhile, the Scoop Studio is reset and ready for the next call. The main menu appears on the screen Auto Answering As soon as the "Power On Initialization" phase is completed, the Scoop Studio is ready to receive an ISDN call or a POTS call. You have just to adjust the levels in such a way that the audio level green and yellow LED's indicate a normal operating range. When a call is received the Scoop Studio will recognize ISDN or POTS and establish a connection. Adjust your headphone level and your local feed back with the local/return mix balance if needed. Then the Scoop Studio is ready for full duplex audio communication Entering local Numbers From the Main Function Menu, go to SETUP, NET, PARAM. Using the down arrow key scroll right to "Address" screen. Press the center key to enter in address configuration You have two address configuration with each sub-address. You have a specific address and sub-address for each B ISDN channel. A series of AT commands will be displayed and automatically return you to the main menu Note : In many case, the subaddress is not necessary Ed. A SCOOP STUDIO - User Manual 25

30 8.5. Entering SPID Numbers ( USA ) In the USA, some ISDN circuits require two SPID numbers and two LDN ( Local directory number ), one SPID for each B channel, in addition to the local dialing number. The Scoop Studio can be manually programmed using the keypad. From the Main Function Menu, go to SETUP, NET, PARAM. Using the down arrow key scroll right to "Address" screen. Press the center key to enter in address configuration Note : - You should enter SPID 1 and LDN 1 local number and before SPID 2 number and LDN 2 - Generally, the LDN is the 4 last digits of the SPID number. 26 SCOOP STUDIO - User Manual Ed. A

31 9. POTS Information 9.1. Factory default configuration The Scoop's factory-set default configuration is suitable for most Scoop Studio transmission applications and are reloaded by the selected function : TOOLS, Misc, General reset. Your Scoop Studio is designed to operate over dial-up phone circuits with the following dialling and call monitor features : Multi-frequency signalling (Tone dialling method) or Loop-disconnect signalling (Pulse dialling method) Rem : By issuing the configuration procedure the user can change the <dialling method> : Pulse or Tone The selection of the dialling method will be stored until the user has to modify his choice again even when the Scoop Studio is power off. Operation in the absence of proceed operation (waiting for dial tone) Automatic answering Originating and answering handshake negotiations begin at the highest DCE line speed configured in the factory (24 kbps) or at lower speed selected by the menu with the current configuration. Automatic speed selection : Handshake negotiations fall back to a lower speed if necessary. Full dial progress detection ( Dial tone detect). Rem :This parameter must be "disable" for calls originated from Switzerland and Italy. Additional setting Fall back if negotiation fails at the highest speed ( speed automatic ) Ed. A SCOOP STUDIO - User Manual 27

32 Maximum DCE Line speed = bps. (Default Config.) 9.2. POTS modes Phone / Codec Mode The telephone mode or the codec mode is selected by the menu ANALOG MODE. If you select Hybrid parameter, you select the phone mode. The change of the initial mode can t be done during the communication. When the high speed connection is broken the Scoop Studio doesn't fall back to the regular POTS mode (3.4 khz). The voice communication is interrupted and a new call has to be made Network parameters Setting the optimal rate The Scoop Studio with the lowest max line speed setting will determine the maximum connect rate. a) When the speed mode function is set on "Automatic" adaptation ( general reset Configuration. ) both modems will negotiate the highest transmission rate according to the quality of their current respective networks. This rate is also limited at the lowest speed of the two max speed selected on the 2 units. If the line quality is changing during the audio-transmission the modems will try to adapt consequently the data rate by fall back at a lower data rate and fall forward to the higher selected speed. During each re-negotiation the audio signal may be interrupted. If these "break down" appear, it is highly recommended to set the max line speed selection of one of the Scoop Studio at one level or two below the used connect rate. 28 SCOOP STUDIO - User Manual Ed. A

33 b) When the speed function is set on "Fixed" at ONE of the both Scoop Studio unit, the 2 modems will be allowed to negotiate at only the lowest speed of the two max speeds selected. They will neither "fall forward" nor "fall back". If this select speed is too high for the possibility of one of the local network capacity, the modem will "NOT CONNECT" and a lower has to be selected by the user to obtain a solid connection at a reliable data rate. Rem : By setting Speed fixed, the user has the ability to select the max/min connect rate for the modems before a call is placed. So the fall back to a lower speed cannot occur during the communication Clock Mode For long distance transmission, it is better to set on free this parameter. The reason is : in this mode, each modem generates the transmit clock and generate receive clock from receive carrier signal. In this case, each way is separated. In standard mode, each modem works with only one clock. The local Scoop Studio generate the clock and the remote generate its clock from receive carrier signal Line level The phone line level depending of country where you are. You can adjust the phone line level between 0dBm to 16dBm. The most popular level is 10dBm ( default value ) Error protection This function reduces the short and occasional transmission errors causing glitches and drop-out in the audio. Those errors can be founded particularly on long distance circuits and when connected to an in-house phone systems. The audio quality could be slightly affected. The user will only hear a short additional delay Ed. A SCOOP STUDIO - User Manual 29

34 Secured modes Three protection modes are available : Protected 0 ( Unprotected ) is set by default ( Factory Configuration ) Is compatible with all Scoop Studio units. Keep the smallest transmission delay ( coding : decoding ) of 80 ms. Protected 1 Ought to be selected manually and recovers errors of 100 ms. Protected 2 Ought to be selected manually and recovers errors of 250 ms. Note : If errors still exist in protected mode 2, set the max line speed at the next lower speed. Caution : The same protection level configuration must be selected at the both end units. 30 SCOOP STUDIO - User Manual Ed. A

35 10. Troubleshooting Network Indication: - Alarm (red) - Dec (green) When on indicates a network problem. Check your network. When "on" indicates that the signal is decoded by the Scoop Studio. Unable to establish a connection: Check the RJ connection between the Scoop Studio and the telephone network. (RJ 11, identified as Tel on the rear panel of Scoop Studio for POTS, and RJ45, identified as ISDN on the rear panel of the Scoop Studio for ISDN) Connection In ISDN mode To test your ISDN line, you may connect an ISDN phone or other suitable ISDN verification device into the RJ45 connector instead of the Scoop Studio and call an ISDN number to verify a working ISDN line. Check the ISDN protocol, check the number, and check appropriate setting if going through a PBX. Connection In POTS mode To test your POTS line, you may connect a normal phone to the wall connector instead of the Scoop Studio unit and call a normal phone number. Check for proper POTS line settings: Dialing method, " Pulse/Tone", dial tone "Detect/Undetected". Check proper setting if going through a PBX ( you may need to dial to get an outside line, Ex 9* ). If the Scoop Studio disconnects while on-line, check for loose connections between the Scoop Studio and the telephone connection. Line noise or interference may be interfering with the modem signals. Retry the connection by dialing the number again Ed. A SCOOP STUDIO - User Manual 31

36 11. Tests Audio section testing 1- Analogue section test a ) Connect an audio signal to one of the audio inputs. That signal is available on the headphones ( Potentiometer turns that feedback feature off when fully counterclockwise ). b ) Select the menu < TOOLS >, < MAINTENANCE >, < Test > : AD/DA Loop. The test is OK if you get the audio signal either on the headphones, or Aux. Out. To end the test go back to the test menu, disable the AD/DA Loop by pressing the none choice ( The star appears on None configuration). 2- Digital and analogue parts The encoder may be connected to the decoder locally to test digital circuits. Connect and select an audio signal to any of the inputs. Select the menu < TOOLS >, < MAINTENANCE >, < Test > : Coding test. The message "Coding process" appears on the screen. The test is OK if you get the audio signal either on the headphones, or Aux. Out. To end the test press the "Esc" key, wait signal is displayed on the screen, then the unit returns to standby Network test These allows checking the network and the remote codec. 32 SCOOP STUDIO - User Manual Ed. A

37 1- The unit can be configured to loop back to the network the received data. Select the main menu < TOOLS >, < MAINTENANCE >, < Test > : Loop 2 - Network. The loop is enabled as soon as the unit is connected. 2- The unit can be configured to loop back to the network the sent data. Select the main menu < TOOLS >, < MAINTENANCE >, < Test > : Loop 3 - codec. The loop is enabled as soon as the unit is connected Ed. A SCOOP STUDIO - User Manual 33

38 12. ISDN modem information ISDN Protocols ISDN modem supports worldwide ISDN signaling (CCITT I.430, Q.921, Q.931) for voice/audio and data including the following network operator variants : With USA software AT&T 5 E 5, 5 E 9, 5 E 10 Northern Telecom (DMS-100), National ISDN-1 and 2 (North America), With other countries software France Telecom EuroNumeris (Vnx) with supplementary services, Deutsche Telekom 1TR6 and EuroISDN, NTT INS-64 (Japan), KDD ISDN (Japan), Telecom Australia Austel TS-013, All EuroISDN carriers (Austria, Denmark, Holland, Ireland, Italy, Norway, Portugal, Spain, Switzerland, United Kingdom,...) ISDN CLEARING CAUSES The following table lists the call clearing causes (returned for example in a CLEARED: message). Call clearing cause is in hexadecimal. Message meaning are given for an ETSI ISDN. Causes with values greater than 80 hex are generated internally. Example : CLEARED 18: 12 means for the 18 reference system call there are no user responding. 34 SCOOP STUDIO - User Manual Ed. A

39 01 unallocated (unassigned) number 02 no route to specified transit network 03 no route to destination 06 channel unacceptable 07 call awarded and being delivered in an established channel 10 normal call clearing 11 user busy 12 no user responding 13 no answer from user (user alerted) 15 call rejected 16 number changed 1A non-selected user clearing 1B destination out of order 1C invalid number format 1D facility rejected 1E response to STATUS ENQUIRY 1F normal, unspecified 22 no circuit/channel available 26 network out of order 29 temporary failure 2A switching equipment congestion 2B access information discarded 2C requested circuit/channel not available 2F resources unavailable, unspecified 31 quality of service unavailable 32 requested facility not subscribed 39 bearer capability not authorized 3A bearer capability not presently available 3F service or option not available, unspecified Ed. A SCOOP STUDIO - User Manual 35

40 41 bearer capability not implemented 42 channel type not implemented 45 requested facility not implemented 46 only restricted digital information bearer capability is available 4F service or option not implemented, unspecified 51 invalid call reference value 52 identified channel does not exist 53 a suspended call exists, but this call identity does not 54 call identity in use 55 no call suspended 56 call having the requested call identity has been cleared 58 incompatible destination 5B invalid transit network selection 5F invalid message, unspecified 60 mandatory information element is missing 61 message type non-existent or not implemented 62 message not compatible with call state or message type non-existent or not or not implemented 63 information element non-existent or not implemented 64 invalid information element contents 65 message not compatible with call state 66 recovery on timer expiry 6F protocol error, unspecified 7F interworking, unspecified 91 no signaling data link establishment A2 no line activation FF call clearing, unspecified 36 SCOOP STUDIO - User Manual Ed. A

41 13. How to open a SCOOP STUDIO ready for servicing Tools required: Philips Screw Driver (medium-sized) The Scoop Studio will be now separated into three Sections : 1) The top metal panel 2) The casing lid Steps : - Switch to off Scoop Studio - Remove the external mains power cable if you use it - Undo screws at the top - Remove the top panel Now, you have access to all internal boards Ed. A SCOOP STUDIO - User Manual 37

42 14. Connectors layout Remote Connector This interface uses a 9-pin female Sub-D connector on the rear panel. This is a V24/RS-232 type interface with only Tx and Rx signals (no flow control). The following table indicates its pin out (DCE type pin out) Pin Description 2 TX, To the PC 3 RX, From the PC 7 CTS, From the PC 8 RTS, To the PC 5 Signal ground POTS Interface The telephone network connection on Scoop Studio is a RJ 11 connector. ( Labeled Analog ) Connector : Pin Description 1-2 TIP 3 RING 4 - Impedance adaptation ( Internal rear panel switches ): Country RZDC ZZNT US 8.2 Ω 600 Ω CTR Ω 600 Ω//0.0047µF Country \ Switch 1 2 US ON OFF CTR-21 OFF ON 38 SCOOP STUDIO - User Manual Ed. A

43 14.3. ISDN Interface Network The ISDN connector is an RJ45 4 wires into 8 wires. S0/T0 Network: Pin Description 1 N.C. 2 N.C. 3 TX A, To the network 4 RX A, From the network 5 RX B, From the network 6 TX, To the network 7 N.C. 8 N.C. U0 NETWORK: Pin Description 1 N.C. 2 N.C. 3 N.C. 4 RING 5 TIP 6 N.C. 7 N.C. 8 N.C External DC connector Pin 1 : Minus Pin 4 : Plus Environment Operating temp. Range: 0 C to 45 C ( 41 F to 113 F ) Humidity: 0 to 90% non -condensing Storage temp. : - 20 C to 60 C ( -4 F to 140 F ) Dimensions: (D x W x H) 270 x 482 x 45 mm Weight: 3.43 kg, Ed. A SCOOP STUDIO - User Manual 39

SCOOP STUDIO. User Manual

SCOOP STUDIO. User Manual SCOOP STUDIO User Manual AETA AUDIO SYSTEMS S.A.S. Parc technologique - Kepler 4 18-22, avenue Edouard Herriot - 92350 Le Plessis Robinson FRANCE Tél. +33 (0)1 41361200 Fax +33 (0)1 41361269 Web : http://www.aeta-audio.com

More information

SCOOP REPORTER II. ISDN / POTS Codec USER MANUEL. Version 2.0 DUAL

SCOOP REPORTER II. ISDN / POTS Codec USER MANUEL. Version 2.0 DUAL SCOOP REPORTER II ISDN / POTS Codec USER MANUEL Version 2.0 DUAL ATA Audio 400 Valley Rd Suite 100 Mt Arlington NJ 07856 PH: 973-659-0555 Fax: 973-659-9555 Web : http://www.ataaudio.com 55 000 007 Ed.

More information

SET2. Portable CODEC. User Manual

SET2. Portable CODEC. User Manual SET2 Portable CODEC User Manual You/Com Audiocommunicatie b.v. Motorenweg 5-k 2623CR Delft (The Netherlands) tel: +31 15 262 59 55 fax: +31 15 257 15 95 e-mail: sales@youcom.nl URL : www.youcom.nl SET2

More information

HIFISCOOP 3 5ASystem

HIFISCOOP 3 5ASystem HIFISCOOP 3 5ASystem Audio codec for transmission over the ISDN or leased lines User Manual AETA AUDIO 361, avenue du Général de Gaulle 92140 Clamart FRANCE Tél. +33 (0)1 41361212 Fax +33 (0)1 41361213

More information

ISDN Switch Types, Codes, and Values

ISDN Switch Types, Codes, and Values A P P E N D I X B ISDN Switch Types, Codes, and Values This appendix contains a list of the supported switch types. It also contains the ISDN cause codes and ISDN bearer capability values, and progress

More information

SCOOPY+ Mono / Stéréo portable audio codec ISDN / POTS / GSM 3G+ / IP. User manual

SCOOPY+ Mono / Stéréo portable audio codec ISDN / POTS / GSM 3G+ / IP. User manual SCOOPY+ Mono / Stéréo portable audio codec ISDN / POTS / GSM 3G+ / IP User manual AETA AUDIO SYSTEMS 18-22, Avenue Edouard Herriot 92350 Le Plessis Robinson FRANCE Tel. +33 (0)1 41361200 Fax +33 (0)1 41361269

More information

GSGC5G ISDN MIXERS PRODUCT DETAILS

GSGC5G ISDN MIXERS PRODUCT DETAILS G GLENSOUND ELECTRONICS LTD Date 22/06/00 File AP71-14 Issue 1 GSGC5G ISDN MIXERS PRODUCT DETAILS CONTENTS Approvals Page 1 General Information Page 2 Installation information Page 3 Operating Instructions

More information

Aculab plc Q931 An Overview

Aculab plc Q931 An Overview Worldwide Digital Connectivity Aculab plc Lakeside - Bramley Road - Mount Farm - Milton Keynes - MK1 1PT UK Tel: +44 (0)1908 273800 Aculab plc Q931 An Overview v 1.0 Proprietary Information Aculab plc.

More information

HIFISCOOP 3 LL. Stereo audio codec or decoder with V24/V11/V35 interface. User Manual. HIFISCOOP 3 LL Full duplex version

HIFISCOOP 3 LL. Stereo audio codec or decoder with V24/V11/V35 interface. User Manual. HIFISCOOP 3 LL Full duplex version HIFISCOOP 3 LL Stereo audio codec or decoder with V24/V11/V35 interface User Manual HIFISCOOP 3 LL Full duplex version AETA AUDIO SYSTEMS S.A.S. Parc technologique - Kepler 4-18-22, avenue Edouard Herriot

More information

GSGC7 OPERATING INSTRUCTIONS

GSGC7 OPERATING INSTRUCTIONS GSGC7 OPERATING INSTRUCTIONS GENERAL This unit has a standard keypad and 4 additional buttons. It also has a 2 line by 16 character LCD display. The display is used to prompt the user and to show various

More information

Stereo audio codec for real time audio transmission User Manual

Stereo audio codec for real time audio transmission User Manual Stereo audio codec for real time audio transmission User Manual Table of contents 1. Presentation Getting started... 1 1.1. Install and connect SCOOP 5... 3 1.2. Audio settings... 3 1.3. Select and set

More information

Stereo audio codec for real time audio transmission User Manual

Stereo audio codec for real time audio transmission User Manual Stereo audio codec for real time audio transmission User Manual Table of contents 1. Presentation Getting started... 1 1.1. Install and connect Scoop5 S...3 1.2. Audio settings...3 1.3. Select and set

More information

Scoop5 S - User Manual

Scoop5 S - User Manual 1.1. Install and connect Scoop5 S... 3 1.2. Audio settings... 3 1.3. Select and set up network to be used: wired networks... 3 1.4. Select and set up network to be used: mobile networks... 5 2.1. Transmission

More information

User Manual for the AN208

User Manual for the AN208 Aristel Networks User Manual for the AN208 2 Line / 9 Handset Telephone System Aristel Networks Pty Ltd Unit 1, 25 Howleys Road Notting Hill. Victoria. 3168 Telephone: 03 8542 2300 Facsimile: 03 9544 3299

More information

Interworking Signaling Enhancements for H.323 and SIP VoIP

Interworking Signaling Enhancements for H.323 and SIP VoIP Interworking Signaling Enhancements for H.323 and SIP VoIP This feature module describes enhancements to H.323 and Session Initiation Protocol (SIP) signaling when interworking with ISDN, T1 channel associated

More information

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR

OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR 1 OPERATOR S MANUAL MODEL LS110 MINI-PBX SIMULATOR Micro Seven, Inc. 1095-K N.E. 25 th Hillsboro, OR 97124 U.S.A. phone: 503-693-6982 fax: 503-693-9742, email to: sales@microseveninc.com www.microseveninc.com

More information

ISDN Cause Definitions

ISDN Cause Definitions ISDN Cause Definitions Handout Table of contents...2 2 Location...7 3 Reference list...7 4 Imprint...7 5 Contact...8 Status: 11.02.2011 2011 Lindenbaum GmbH The European Telecommunication Standard (ETS)

More information

VP-8LVCT User s Manual First Edition. Copyright 2001, Eletech Enterprise Co. Ltd. All Rights Reserved.

VP-8LVCT User s Manual First Edition. Copyright 2001, Eletech Enterprise Co. Ltd. All Rights Reserved. VP-8LVCT User s Manual First Edition Copyright 2001, Eletech Enterprise Co. Ltd. All Rights Reserved. Table of Contents Chapter 1: Overview... 3 1.1 Basic Functions... 3 1.2 Features... 4 1.3 Applications...

More information

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio

PBXport. Rackmount PBX Digital Hybrid. User Guide. JK Audio PBXport Rackmount PBX Digital Hybrid User Guide JK Audio Introduction PBXport will allow you to send and receive audio through your multiline PBX, ISDN or analog telephone. While this may seem like a simple

More information

Thank you for purchasing Parrot CK3000, the hands-free kit with voice recognition equipped with Bluetooth TM radio technology.

Thank you for purchasing Parrot CK3000, the hands-free kit with voice recognition equipped with Bluetooth TM radio technology. Thank you for purchasing Parrot CK3000, the hands-free kit with voice recognition equipped with Bluetooth TM radio technology. Parrot CK3000 offers you the following functions: Wireless radio connection

More information

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual

TELIKOU Intercom System. FM Wire Matrix Control Station. Instruction Manual Intercom System FM-804 4-Wire Matrix Control Station Instruction Manual Systems All Rights Reserved I. Introduction Thank you for choosing intercom product. FM-804 is a eight channel four wire matrix control

More information

AEQ PHOENIX MOBILE USER S MANUAL ED. 02/09 V /11/2010

AEQ PHOENIX MOBILE USER S MANUAL ED. 02/09 V /11/2010 USER S MANUAL ED. 02/09 V. 1.1-22/11/2010 Firmware Versions: Micro 4.06 / DSP 4.04 / FPGA 1.47 or higher PGA-01 POTS Module: Micro 1.05 PGA-03 ISDN Module: Micro 1.01 / TA 6.00 A.E.Q., S.A., the company

More information

This chapter describes the core features in the Prima LT Plus

This chapter describes the core features in the Prima LT Plus Chapter 1 Feature Overview This chapter describes the core features in the Prima LT Plus 1. Prima LT Plus Overview The Prima LT Plus is an audio codec that is used to encode and decode audio for transmission

More information

Starlink 9003T1 T1/E1 Digital Transmission

Starlink 9003T1 T1/E1 Digital Transmission Starlink 9003T1 T1/E1 Digital Transmission A Digital Audio via T1/E1 C ombining Moseley s unparalleled reputation for high quality RF aural Studio-Transmitter Links (STLs) with the performance and speed

More information

ISDN / POTS / MOBILE / IP

ISDN / POTS / MOBILE / IP Mono/stereo portable audio codec for real time transmission over ISDN / POTS / MOBILE / IP User Manual Table of contents 1. Presentation Getting started... 1 1.1. Install and connect SCOOPY+ S... 3 1.2.

More information

User Guide Speaker phone GewaTel 200. English

User Guide Speaker phone GewaTel 200. English User Guide Speaker phone GewaTel 200 This package contains the following items: 1 x User guide 1 x Speaker phone 1 x Mains transformer 1 x Power supply and network cable Tele plug Please check the contents.

More information

Getting started

Getting started www.aeta-audio.com Getting started Specifications are subject to change without notice 55000103-B 2018 FRONT PANEL AND CONTROLS 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 1. Microphone potentiometer:

More information

900 MHz Digital Two-Line Cordless Speakerphone with Answering System 9452 with Caller ID/Call Waiting

900 MHz Digital Two-Line Cordless Speakerphone with Answering System 9452 with Caller ID/Call Waiting USER S MANUAL Part 2 900 MHz Digital Two-Line Cordless Speakerphone with Answering System 9452 with Caller ID/Call Waiting Please also read Part 1 Important Product Information AT&T and the globe symbol

More information

Model KS308/416 System Administration Guide

Model KS308/416 System Administration Guide Model KS308/416 System Administration Guide Introduction 3 Installation Hints 4 System Programming 5 IMPORTANT Exchange Lines 6 Assign Incoming calls to ring Nominated Extensions 7 Cascade Ringing Of Extensions

More information

Multiserver User s Manual

Multiserver User s Manual Multiserver 3000 User s Manual May 1996 Black Box iii Black Box iv Black Box Black BoxBlack Box Black Box BlackBox Black Box Black Box BlackBox BlackBox BLACKBOX BLACKBOX Black Box may Black Box Black

More information

F271XA Fiber-Optic Telephone Modem Technical Manual

F271XA Fiber-Optic Telephone Modem Technical Manual F271XA Fiber-Optic Telephone Modem Technical Manual Revision B August 2011 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since 1958 PROPRIETARY

More information

Defined Cause Codes. For reference purposes, defined cause codes are listed in Table E-1 through Table E-7.

Defined Cause Codes. For reference purposes, defined cause codes are listed in Table E-1 through Table E-7. APPENDIXE Revised: May 31, 2010, For reference purposes, defined cause codes are listed in Table E-1 through Table E-7. Table E-1 Cisco BTS 10200 Softswitch Normal Events Normal Event 1. [Note 1] 1. Unallocated

More information

Issue G GLENSOUND ELECTRONICS LTD. Broadcast Equipment Manufacturers. Copper 29 Glensound Telephone balance Unit Handbook

Issue G GLENSOUND ELECTRONICS LTD. Broadcast Equipment Manufacturers. Copper 29 Glensound Telephone balance Unit Handbook Issue 2 G GLENSOUND ELECTRONICS LTD. Broadcast Equipment Manufacturers Copper 29 Glensound Telephone balance Unit Handbook G G L E N S O U N D E L E C T R O N I C S L I M I T E D Copper 29 HANDBOOK G Glensound

More information

Second Phone Line Kit Manual for sx1480/fx2080

Second Phone Line Kit Manual for sx1480/fx2080 Second Phone Line Kit Manual for sx1480/fx2080 Contents Regulatory information...i Users in United States of America... i FCC Part 15... ii Users in Canada...iii Canadian ICES-003...iii Setting up...1-1

More information

DST-24B/PCI DST-24B/PCI+ DST-24B/PCI(2.0) DST-24B/PCI+(2.0) DST-24B/PCIe(2.0) DST-24B/PCIe+(2.0) Digital Station Tap Board

DST-24B/PCI DST-24B/PCI+ DST-24B/PCI(2.0) DST-24B/PCI+(2.0) DST-24B/PCIe(2.0) DST-24B/PCIe+(2.0) Digital Station Tap Board Synway DST Series DST-24B/PCI DST-24B/PCI+ DST-24B/PCI(2.0) DST-24B/PCI+(2.0) DST-24B/PCIe(2.0) DST-24B/PCIe+(2.0) Digital Station Tap Board Synway Information Engineering Co., Ltd www.synway.net Functions

More information

All Rights Reserved. February 2005 Version 1.1

All Rights Reserved. February 2005 Version 1.1 All Rights Reserved The use, disclosure, modification, transfer or transmittal of this work for any purpose, in any form, or by any means, without the written permission from Net2Phone is strictly forbidden.

More information

Interchange LTD. JK Audio. Intercom Phone Bridge + Digital Hybrid. User Guide

Interchange LTD. JK Audio. Intercom Phone Bridge + Digital Hybrid. User Guide Interchange LTD Intercom Phone Bridge + Digital Hybrid User Guide JK Audio Welcome Thank You Thank you for purchasing a JK Audio Interchange LTD Intercom Phone Bridge. Please read this guide for instructions

More information

1ISDN ERROR CODES. October ISDN Error Codes Software Reference 1

1ISDN ERROR CODES. October ISDN Error Codes Software Reference 1 1ISDN ERROR CODES October 2002 ISDN Error Codes Software Reference 1 2 Software Reference ISDN Error Codes Table of Contents ISDN Table of Contents ERROR CODES A REFERENCE 5 1 ISDN Error Codes 6 1.1 Overview

More information

RTS ISDN 2002 System. Operator Manual Software Description

RTS ISDN 2002 System. Operator Manual Software Description RTS ISDN 2002 System Operator Manual Software Description PAGE 1-2 RTS ISDN 2002 System A Publication of EVI Audio GmbH Hirschberger Ring 45 D-94315 Straubing Telephone + 49 9421 706-0 Fax + 49 9421 706-422

More information

DATA CONNECT ENTERPRISE

DATA CONNECT ENTERPRISE DATA CONNECT ENTERPRISE User s Manual IG202T and IGV23 Modem Document Number 520-01005-001 Rev. A DATA CONNECT Contents Contents... iii Figures... iv Chapter 1 Introduction... 5 Features...6 Applications...7

More information

User guide Conference phone Konftel 200

User guide Conference phone Konftel 200 User guide Conference phone Konftel 200 Deutsch I I Français I Italiano Conference phones for every situation This package includes the following items: 1 pc User Guide 1 pc Conference Phone 1 pc Mains

More information

Installation Manual & User Instructions

Installation Manual & User Instructions Installation Manual & User Instructions For BFT Americas. Inc. 6100 Broken Sound Parkway N.W. Suite 14, Boca Raton, FL 33487 Toll Free: 877-995-8155 Office: 561-995-8155 Fax: 561-995-8160 1 P a g e M u

More information

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016

PS 150 SINGLE CHANNEL TELEPHONE INTERFACE. USER MANUAL August 2016 PS 150 SINGLE CHANNEL TELEPHONE INTERFACE USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax:

More information

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER

MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER OWNERS MANUAL MODEL 801R REMOTE CONTROL MICROPHONE PREAMPLIFIER Software version 1.4 PO Box 204 Boulder, CO 80306 tel:303.443.7454 fax: 303.444.4634 http://www.gracedesign.com Revision B January, 2000

More information

Dialler HA2000 RTC. Installation & Operating Manual

Dialler HA2000 RTC. Installation & Operating Manual Dialler HA2000 RTC Installation & Operating Manual The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a tabletop before

More information

Sutron Voice Modem Operation Manual

Sutron Voice Modem Operation Manual Sutron Voice Modem Operation Manual Models: 8080-0005-1 and -2 TABLE OF CONTENTS Overview...1 Jumpers and Connections...2 Recommended Jumper Settings...2 Operation with the Xpert/Xlite...3 Operation with

More information

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO

F8008. Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet. + optional V.35/QFXS/QFXO F8008 Fiber Modem for up to 4E1 /8E1 +RS232+Ethernet + optional V.35/QFXS/QFXO Description F8008 is a fiber optical multiplexer of new generation different from the traditional PDH, multiplexing 1 full

More information

Emutel Series Emutel Solo and Emutel Duo

Emutel Series Emutel Solo and Emutel Duo Emutel Series Emutel Solo and Emutel Solo Small, portable and lightweight battery powered basic rate ISDN network Different versions simulate Euro-ISDN, North American or NTT networks Two S/U software

More information

EAR K. Installation and Programming. Manual

EAR K. Installation and Programming. Manual EAR 2000 4K Installation and Programming Manual EAR 2000 4K Installation and Programming Manual Release 1 Version 3 June 2011 NOTICE This publication refers to the EAR 2000, Release 3. Additional copies

More information

CDQPrima Digital Audio Codecs Models 110, 120, 210, 220 & 230 Intelligent codecs for remote digital audio with the world s best sound

CDQPrima Digital Audio Codecs Models 110, 120, 210, 220 & 230 Intelligent codecs for remote digital audio with the world s best sound CDQPrima Digital Audio Codecs Models 110, 120, 210, 220 & 230 Intelligent codecs for remote digital audio with the world s best sound Full Duplex Bi-Directional 20 khz Stereo Best Digital Audio Quality

More information

A Guide to Understanding Analog Fax in Digital Environments

A Guide to Understanding Analog Fax in Digital Environments A Guide to Understanding Analog Fax in Digital Environments 2010 OkiData Americas, Inc. Disclaimer Every effort has been made to ensure that the information in this document is complete, accurate, and

More information

Model PBX 207. Programming & User Guide

Model PBX 207. Programming & User Guide Model PBX 207 Programming & User Guide 1 Index Page Introduction 4 Installation 4 Wall Mounting 4 System Programming 4 System Password 4 Changing the Password 5 Exchange Line Set up 5 One or Two Lines?

More information

Interchange LTD. JK Audio. Intercom Phone Bridge + Digital Hybrid. User Guide

Interchange LTD. JK Audio. Intercom Phone Bridge + Digital Hybrid. User Guide Interchange LTD Intercom Phone Bridge + Digital Hybrid User Guide JK Audio Welcome Thank You Thank you for purchasing a JK Audio Interchange LTD Intercom Phone Bridge. Please read this guide for instructions

More information

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual

F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual F271XAD Fiber-Optic Telephone Modem with RS485 Data Technical Manual Revision A January 2014 VERSITRON, Inc. 83 Albe Drive / Suite C Newark, DE 19702 www.versitron.com Safeguarding Communications Since

More information

Model PBX816ex. Programming & User Guide

Model PBX816ex. Programming & User Guide Model PBX816ex Programming & User Guide 1 Introduction... 5 Installation hints... 5 Expanding Your System 5 System programming... 6 System password... 6 Changing the password... 6 Exchange line set up...

More information

IC+ 56k External Data Fax Voice Modem IP568x User s Guide

IC+ 56k External Data Fax Voice Modem IP568x User s Guide IC + 56k External Data Fax Voice Modem IP568x FCC Requirements This equipment complies with Part 68 of the FCC Rules. On the bottom of this equipment is a label that contains, among other information,

More information

TLE-02D Portable Digital Communications Unit / Unidad Digital de Comunicaciones Portátil USER S MANUAL / MANUAL DE USUARIO ED.

TLE-02D Portable Digital Communications Unit / Unidad Digital de Comunicaciones Portátil USER S MANUAL / MANUAL DE USUARIO ED. Portable Digital Communications Unit / Unidad Digital de Comunicaciones Portátil USER S MANUAL / MANUAL DE USUARIO ED. 08/99 A.E.Q., S.A. the manufacturer of this equipment, is Registered Company number

More information

Page 2

Page 2 Page 2 Índice de contenido About this manual...5 What's in the box...5 1. Overview...5 1.1 Features... 5 Maximize the cell phone transmission...5 Designed for Internet...5 High performance...6 1.1.1 Inputs...6

More information

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 230 DUAL CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 SIDE PANEL CONNECTORS...

More information

User Guide Konftel 220 ENGLISH

User Guide Konftel 220 ENGLISH User Guide Konftel 220 ENGLISH OmniSound HD Optimal sound By incorporating full duplex audio, the patented audio technology OmniSound guarantees the audio conference an impressive and crystal clear sound

More information

660/960 Installation Guide

660/960 Installation Guide 660/960 Installation Guide Compatible Equipment 660: Any Scantronic control panel. 960: All control panels with the Scantronic plug-on footprint pins. 496354 Issue 1 1 of 16 660/960 Introduction The 660/960

More information

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

WIRESPEED ADSL MODEM (MODEL 2000) User Guide WIRESPEED ADSL MODEM (MODEL 2000) User Guide Copyright 2001 Westell, Inc. All rights reserved. 030-300187 Rev. A Printed in the United States of America December 2001 CONTENTS 1. PRODUCT DESCRIPTION...

More information

IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS When using this electronic device, basic precautions should always be taken, including the following: 1. Read all instructions before using the product. 2. Do not use this

More information

EAR 1000 / ADRA 1000 / Installation and Programming Manual

EAR 1000 / ADRA 1000 / Installation and Programming Manual EAR 1000 / 2 000 ADRA 1000 / 2000 Installation and Programming Manual EAR 1000/2000 and ADRA 1000/2000 Installation and Programming Manual Release 3 Version 3 February 2004 NOTICE This publication refers

More information

Alcatel DECT 209 Wireless PBX System

Alcatel DECT 209 Wireless PBX System Alcatel DECT 209 Wireless PBX System USER GUIDE 1 User Guide Index Contents 4 Installation 5 The Base 5 The Handset 6 Charger 6 Battery Cover 7 Handset Keys 7 LCD Icons 8 Standby Mode 8 Receiving a Call

More information

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION

USER MANUAL. G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION USER MANUAL G.shdsl+ modem with G.703 interface TAHOE 671 FREEDOM OF COMMUNICATION TABLE OF CONTENTS 1. Introduction... 1 2. Interfaces... 2 3. Modem configuration using built-in keyboard and LCD.4 4.

More information

AX3000 Platine Terminal Ethernet TCP/IP

AX3000 Platine Terminal Ethernet TCP/IP AX3000 Platine Terminal Ethernet TCP/IP Model 55E Installation Guide February 2002 - Ref: I55EE0210-1 Model AX3000/M55E The reproduction of this material, in part or whole, is strictly prohibited. For

More information

TELIKOU Intercom System

TELIKOU Intercom System TELIKOU Intercom System MS-800 Main Station Instruction Manual 2006 TELIKOU Systems All Rights Reserved While TELIKOU makes every attempt to maintain the accuracy of the information contained in its product

More information

PRELIMINARY DATA SHEET AM 1 AUTOMIXER SHIPS APRIL 2010

PRELIMINARY DATA SHEET AM 1 AUTOMIXER SHIPS APRIL 2010 PRELIMINARY DATA SHEET SHIPS APRIL 00 AM MIC INPUTS 4 MIC AUX AUX SOURCE PHONES AUX AUX MICS AM G OL G OL G OL LOCATE General Description The Rane AM is part gain-sharing automatic mic mixer, part manual

More information

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20 SS-10 3G FIXED CELLULAR TERMINAL USER MANUAL DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20 Revision History: Revision 01 Original document 12 August 2010 CONTENTS 1 INTRODUCTION...3 2 FEATURES...4 2.1 PHYSICAL

More information

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01 Aristel Networks Pty Ltd All Round Cabling Solutions NEOS3003-3G01 Operating Manual * NEOS 3003-3G01 Supports 3G/UMTS 800/850/900/1900/2100 MHz bands Telstra-Vodafone-Optus supported in all areas. * Model:

More information

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 630 SIX CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 630 SIX CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 REAR PANEL CONNECTORS...

More information

User s Manual. VDSL CO / CPE Modem. Model No.: SP3501AM/SP3501AS.

User s Manual. VDSL CO / CPE Modem. Model No.: SP3501AM/SP3501AS. User s Manual VDSL CO / CPE Modem Model No.: SP3501AM/SP3501AS http://www.micronet.info Table of Contents Chapter 1 Introduction... 1 1.1 Package Contents... 1 1.2 Key Features... 1 Chapter 2 Installation...

More information

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment. Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1 This manual contains important information. Please read before using the equipment. Contents 3 Function Description:...4 4 Operation Guide:...4 4.1

More information

INTERNATIONAL TELECOMMUNICATION UNION. SERIES Q: SWITCHING AND SIGNALLING Interworking of Signalling Systems Specifications of Signalling System No.

INTERNATIONAL TELECOMMUNICATION UNION. SERIES Q: SWITCHING AND SIGNALLING Interworking of Signalling Systems Specifications of Signalling System No. INTERNATIONAL TELECOMMUNICATION UNION CCITT Q.763 THE INTERNATIONAL TELEGRAPH AND TELEPHONE CONSULTATIVE COMMITTEE (11/1988) SERIES Q: SWITCHING AND SIGNALLING Interworking of Signalling Systems Specifications

More information

User Guide Konftel 220 ENGLISH. Tel: +44 (0) Fax: +44 (0)

User Guide Konftel 220 ENGLISH.  Tel: +44 (0) Fax: +44 (0) User Guide Konftel 220 ENGLISH www.voipon.co.uk sales@voipon.co.uk Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299 OmniSound HD Optimal sound By incorporating full duplex audio, the patented audio technology

More information

HP4 headphone amplifier. user manual

HP4 headphone amplifier. user manual HP4 headphone amplifier user manual Musikhaus Thomann Thomann GmbH Hans-Thomann-Straße 1 96138 Burgebrach Germany Telephone: +49 (0) 9546 9223-0 E-mail: info@thomann.de Internet: www.thomann.de 03.11.2015,

More information

Installation Manual & User Instructions. MultiCom 500

Installation Manual & User Instructions. MultiCom 500 Installation Manual & User Instructions For MultiCom 500 Multi resident GSM Intercom System Contents Section Description Page 1 Introduction 3 2 Getting started 3 3 SIM card 3 4 Wiring 4 5 Keypad / onscreen

More information

Net-Log Network Audio Logger

Net-Log Network Audio Logger Net-Log Network Audio Logger August 2008 www.sonifex.co.uk t: +44 (0)1933 650 700 f: +44 (0)1933 650 726 sales@sonifex.co.uk Net-log - Network Audio Logger The Net-Log is a new way to record and play audio.

More information

Cisco Model EPC2202 EuroDOCSIS 2.0 Cable Modem with Embedded Digital Voice Adapter

Cisco Model EPC2202 EuroDOCSIS 2.0 Cable Modem with Embedded Digital Voice Adapter Cisco Model EPC2202 EuroDOCSIS 2.0 Cable Modem with Embedded Digital Voice Adapter The Cisco Model EPC2202 EuroDOCSIS 2.0 Cable Modem with Embedded Digital Voice Adapter (EPC2202) is a high-speed cable

More information

ISDN S0 Loopback Device

ISDN S0 Loopback Device TSU2064 ISDN S0 Loopback Device Basic Rate ISDN Test Tool Issue 3.1 TECHNICAL: SALES: FAX: ADDRESS: WEB: (0870) 90 10 750 (0870) 90 10 750 (0118) 965 5001 464 Basingstoke Road, Reading, Berkshire, RG2

More information

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty

Four IFB. Multi Line Phone Bridge. User Guide. JK Audio. Warranty Warranty Four IFB is covered by a 2-year warranty to be free from defective workmanship and materials. In the event that the Four IFB needs repair, you must call us to get an authorization, and then carefully

More information

TELECOMMUNICATION SYSTEMS

TELECOMMUNICATION SYSTEMS TELECOMMUNICATION SYSTEMS By Syed Bakhtawar Shah Abid Lecturer in Computer Science 1 Public Switched Telephone Network Structure The Local Loop Trunks and Multiplexing Switching 2 Network Structure Minimize

More information

GS-HL-005 HD VOICE. Mobile Telephones. Key Points. mobile telephone. Glensound. Broadcasters Mobile Phones A Range Of 2G and 3G Phones For Broadcast

GS-HL-005 HD VOICE. Mobile Telephones. Key Points. mobile telephone. Glensound. Broadcasters Mobile Phones A Range Of 2G and 3G Phones For Broadcast Mobile Telephones Glensound Electronics Ltd mobile telephone Glensound HD Voice offers 7kHz audio bandwidth (HD Voice units) on 3G Quad band phone GS-HL-005 GS-MPI004HD Complete RF shielding of all audio

More information

The Konftel 250 User Guide

The Konftel 250 User Guide Conference phones for every situation The Konftel 250 User Guide ENGLISH Table of contents Our patented audio technology, OmniSound, is embedded into all Konftel phones to ensure crystal-clear voice transmission.

More information

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England.

T L Audio INDIGO SERIES. User Manual C-2021 VALVE COMPRESSOR. Tony Larking Professional Sales Limited, Letchworth, England. T L Audio INDIGO SERIES User Manual C-2021 VALVE COMPRESSOR Tony Larking Professional Sales Limited, Letchworth, England. Tel: 01462 490600. International +44 1462 490600. Fax: 01462 490700. International

More information

Kilomux-2100/2104 KVF.8 8-Channel Analog Voice Compression Module

Kilomux-2100/2104 KVF.8 8-Channel Analog Voice Compression Module Data Sheet Kilomux-2100/2104 KVF.8 Up to 96 analog voice channels in a single Kilomux-2100/2104 chassis Group III Fax relay at up to 14.4 kbps, with automatic rate fallback V.22 bis and V.32 bis modem

More information

GSM FIXED WIRELESS TERMINAL

GSM FIXED WIRELESS TERMINAL AN1001 GSM FIXED WIRELESS TERMINAL USER MANUAL V 4.3 This manual contains important information. Please read before using the equipment. AN1001 GSM FWT User Manual Rev 4.3 April 2010 1 Contents 1 Introduction

More information

Congratulations! Installation Connecting the telephone Features: Caller ID service Setting Clock (Date and Time)

Congratulations! Installation Connecting the telephone Features: Caller ID service Setting Clock (Date and Time) Congratulations! You are now the owner of a VEF&CO Phone telephone set, a quality communications product. To ensure trouble-free operation, please read these instructions carefully before beginning installation.

More information

INTRODUCTION SAFETY INSTRUCTION FEATURES

INTRODUCTION SAFETY INSTRUCTION FEATURES INTRODUCTION Thank you for your purchasing our newest Caller ID phone with phonebook function. This manual is designed to familiarize you with this phone. To get the maximum use from your new phone, we

More information

Synopsis of Basic VoIP Concepts

Synopsis of Basic VoIP Concepts APPENDIX B The Catalyst 4224 Access Gateway Switch (Catalyst 4224) provides Voice over IP (VoIP) gateway applications for a micro branch office. This chapter introduces some basic VoIP concepts. This chapter

More information

ISDN TRAINING SETUP. This trainers provides training of hardware and software theory of ISDN technology. (1) ISDN Exchange 101-2

ISDN TRAINING SETUP. This trainers provides training of hardware and software theory of ISDN technology. (1) ISDN Exchange 101-2 ISDN TRAINING SETUP This trainers provides training of hardware and software theory of ISDN technology. (1) ISDN Exchange 101-2 1. Power Adapter Input : 110/220 VAC Output: 9 VDC, 600mA. 2.5mm jack 2.

More information

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel...

Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... User's Manual Contents Overview... 3 Features... 4 Applications... 4 Specifications... 5 Packing... 6 Appearance... 7 Front Panel... 7 Rear Panel... 8 Important Safety Instructions... 9 Installation...11

More information

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0 PS 430 FOUR CHANNEL REMOTE SPEAKER STATION User Manual January 2017 V1.0 Table of contents 1.0 GENERAL DESCRIPTION... 3 2.0 INSTALLATION... 4 3.0 FRONTPANEL CONTROLS & CONNECTORS... 4 4.0 SIDE PANEL CONNECTORS...

More information

BlueKeeper. Wireless Audio Gateway. User Guide. JK Audio

BlueKeeper. Wireless Audio Gateway. User Guide. JK Audio BlueKeeper Wireless Audio Gateway User Guide JK Audio Introduction JK Audio combines Bluetooth* Wireless Technology with professional audio electronics in a convenient desktop design. BlueKeeper pairs

More information

AT Commands - Trust 56K PCI Modem - Executing commands

AT Commands - Trust 56K PCI Modem -   Executing commands AT Commands - Trust 56K PCI Modem - www.trust.com/11709 Executing commands Your modem is in Command Mode upon power-on and is ready to receive and execute AT commands. The modem remains in Command Mode

More information

Aristel AN1001 GSM FIXED WIRELESS TERMINAL MANUAL V4.2. This manual contains important information. Please read before using the equipment.

Aristel AN1001 GSM FIXED WIRELESS TERMINAL MANUAL V4.2. This manual contains important information. Please read before using the equipment. Aristel AN1001 GSM FIXED WIRELESS TERMINAL MANUAL V4.2 This manual contains important information. Please read before using the equipment. Contents 1 Introduction. 2 Warning 3 Function Description 4 Operation

More information

MASELEC MTC-6 master transfer and monitor system

MASELEC MTC-6 master transfer and monitor system MASELEC MTC-6 master transfer and monitor system http://www.maselec.com/ Mases Electronics Ltd. Bishopswood, Cannon Hill Close, Bray, Berks SL6 2DH, England. Tel/Fax: +44 (0) 1628-770 104. E-mail: leif@maselec.com

More information

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011

LX8 emfone. Installation and Configuration. TVL No. 336 Issue No. 1 03/10/2011 LX8 emfone Installation and Configuration TVL No. 336 Issue No. 1 03/10/2011 Thames Valley Controls Unit 15 Manor Farm Industrial Estate Flint Flintshire CH6 5UY T: +44 (0) 1352 793222 F: +44 (0) 1352

More information

Phone Quick Reference Guide. Rev2. M I T E L. EMEA CALA. Global Headquarters U.S. Asia Pacific

Phone Quick Reference Guide. Rev2. M I T E L.   EMEA CALA. Global Headquarters U.S. Asia Pacific M I T E L 3000 Phone Quick Reference Guide. Rev2. Global Headquarters U.S. EMEA CALA Asia Pacific Tel: +1(613) 592-2122 Fax: +1(613) 592-4784 Tel: +1(480) 961-9000 Fax: +1(480) 961-1370 Tel: +44(0)1291-430000

More information