Product manual. ABB Ability TM Asset Health for electrical systems MyRemoteCare Gateway installation and service instructions

Size: px
Start display at page:

Download "Product manual. ABB Ability TM Asset Health for electrical systems MyRemoteCare Gateway installation and service instructions"

Transcription

1 Product manual ABB Ability TM Asset Health for electrical systems MyRemoteCare Gateway installation and service instructions

2 2 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL

3 3 Disclaimer The data, examples and diagrams in this manual are included solely for the concept or product description and are not to be deemed as a statement of guaranteed properties. All persons responsible for applying the equipment addressed in this manual must satisfy themselves that each intended application is suitable and acceptable, including that any applicable safety or other operational requirements are complied with. In particular, any risks in applications where a system failure and/ or product failure would create a risk for harm to property or persons (including but not limited to personal injuries or death) shall be the sole responsibility of the person or entity applying the equipment, and those so responsible are hereby requested to ensure that all measures are taken to exclude or mitigate such risks. This document has been carefully checked by ABB but deviations cannot be completely ruled out. In case any errors are detected, the reader is kindly requested to notify the manufacturer. Other than under explicit contractual commitments, in no event shall ABB be responsible or liable for any loss or damage resulting from the use of this manual or the application of the equipment. Conformity This product complies with the directive of the Council of the European Communities on the approximation of the laws of the Member States relating to electromagnetic compatibility (EMC Directive 2004/08/EC) and concerning electrical equipment for use within specified voltage limits (Low-voltage directive 2006/95/EC). This conformity is the result of tests conducted by ABB in accordance with the product standards EN and EN for the EMC directive, and with the product standards EN and EN for the low voltage directive. The Gateway is designed in accordance with the international standards of the IEC series. Safety information Dangerous voltages can occur on the connectors, even though the auxiliary voltage has been disconnected. Non-observance can result in death, personal injury or substantial property damage. Only a competent electrician is allowed to carry out the Electrical installation. National and local electrical safety regulations must always be followed. The Gateway contains components which are sensitive to electrostatic discharge. Unnecessary touching of electronic components must therefore be avoided.

4 4 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL Table of contents Introduction. This manual.2 Intended audience.3 Product documentation.4 Symbols and conventions 2 Environmental aspects 2. Sustainable development 2.2 Disposing of the Gateway 3 Gateway functional features and general description 3. Gateway description and features 4 Gateway hardware configuration and parameters 4. External interfaces 4.2 Detailed specifications 5 Technical data 6 Configuration 6. Login 6.2 Status 6.3 System 6.4 Gateway 6.5 Users 6.6 Network

5 TABLE OF CONTENTS Complete Gateway and accessory ordering information 7. Order code information 8 Unpacking, inspection and storing 8. Removing transport packing 8.2 Inspecting the product 8.3 Storing 9 Mounting 9.3 Checking environmental conditions and mounting space 9.2 Dimension 0 Removing, repairing and exchanging 0. Checking Gateway information 0.2 Removing the Gateway 0.3 Sending the Gateway for repair 0.4 Exchanging the Gateway Glossary

6 6 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL Introduction 0 The intended use of manuals in different lifecycles. This manual User manual provides instructions for operation, installation, configure and communication to Gateway. Operation section contains instructions on how to operate the gateway once it has been commissioned. The section provides instructions for monitoring, controlling and setting the Gateway..2 Intended audience This manual addresses the engineer/operator, who engineering/operates the Gateway on a daily basis. Service section contains instructions on how to service and maintain the gateway. The section also provides procedures for de-energizing, de-commissioning and disposal of the Gateway. The engineer/operator must be trained in advance and have a basic knowledge of how to operate equipment. Application section contains application descriptions and setting guidelines sorted per function..3 Product documentation.3. Product documentation set Mounting Planning & purchase Engineering Installation Commissioning Operation Maintenance Decommissioning deinstalling & disposal Technical section contains application and functionality descriptions and lists function blocks, logic diagrams, input and output signals, setting parameters and technical data sorted per function. The section can be used as a technical reference during the engineering phase, installation and commissioning phase, and during normal service. Some of the sections are not available yet. Or some sections will be combined together. Commissioning Operation Service.3.2 Document revision history Document revision/date Product version A/208-xx-xx.0 History First release Configuration Technical 0 Mounting section contains instructions on how to mount the Gateway, and the dimension of Gateway. Download the latest documents from the ABB web site http: // Related documentation Related documentation can be downloaded from the ABB web site

7 INTRODUCTION 7.4 Symbols and conventions.4. Safety indication symbols This publication includes icons that point out safety-related conditions or other important information. The electrical warning icon indicates the presence of a hazard which could result in electrical shock. The warning icon indicates the presence of a hazard which could result in personal injury. The information icon alerts the reader to important facts and conditions. The tip icon indicates advice on, for example, how to design your project or how to use a certain function..4.2 Document conventions Abbreviations and acronyms in this manual are spelled out in Glossary Glossary also contains definitions of important terms. The caution icon indicates important information or warning related to the concept discussed in the text. It might indicate the presence of a hazard which could result in corruption of software or damage to equipment or property.

8 8 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 2 Environmental aspects 2. Sustainable development Sustainability has been taken into account from the beginning of the product design including the pro-environmental manufacturing process, long life time, operation reliability and disposing of the Gateway. The choice of materials and the suppliers have been made according to the EU RoHS directive (2002/95/EC). This directive limits the use of hazardous substances which are the following: Table :Maximum concentration values by weight per homogeneous material Substance Lead - Pb 0.% Mercury - Hg 0.% Cadmium - Cd 0.0% Hexavalent Chromium Cr (VI) 0.% Polybrominated biphenyls- PBB 0.% Polybrominated diphenyl ethers- PBDE 0.% Proposed maximum concentration Operational reliability and long life time have been assured with extensive testing during the design and manufacturing processes. Moreover, long life time is supported by maintenance and repair services as well as by the availability of spare parts. Design and manufacturing have been done under a certified environmental system. The effectiveness of the environmental system is constantly evaluated by an external auditing body. We follow environmental rules and regulations systematically to evaluate their effect on our products and processes. 2.2 Disposing of the Gateway Definitions and regulations of hazardous materials are country-specific and change when the knowledge of materials increases. The materials used in this product are typical for electric and electronic devices. All parts used in this product are recyclable. When disposing of an Gateway or its parts contact a local waste handler who is authorized and specialized in disposing electronic waste. These handlers can sort the material by using dedicated sorting processes and dispose of the product according to the local requirements. Table 2:Materials of the Gateway parts Gateway Case Internal module Packing Attached material Parts Plastic parts Metallic plates, parts and screws PCBA Module Plastic parts Box Manuals Material PA66+GF30 Aluminum alloy Various PC,ABS Cardboard Paper Before sending or exchanging Gateway for repair, please power on the gateway and press Reset button 0 seconds to reset the Gateway. Reset the gateway to purge all setting data, but TF card will not be reset.

9 GATEWAY FUNCTIONAL FEATURES AND GENERAL DESCRIPTION 9 3 Gateway functional features and general description 3. Gateway description and features 3.. General description MyRemoteCare Gateway is a product for connecting substation devices to the ABB Ability Platform. MyRemoteCare gateway is an internet+ gateway that supports various communication interfaces such as LTE, Wi-Fi, Zigbee, Ethernet, and RS485 serial communication. MyRemoteCare gateway also provides Web HMI for easy configuration Gateway features Operating temperature: -40 C ~ 70 C Power supply options: Universal (0 ~ 220 V AC/DC, 24~48 V DC) Zigbee wireless communication Wi-Fi communication 3G/4G communication Modbus serial communication 0 M/00 M ports (LAN WAN)

10 0 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 4 Gateway hardware configuration and parameters 02 Appearance 03 Front panel 4. External interfaces Front panel 03 Reset Use a pin to push the reset button of this device for 0 second while the device is powered on to reset the factory default settings LED indication Table 3:LED State LED Zigbee 2 Wifi 3 3G/4G 4 Power LED state Always On/Off Flashing Always On/Off F lashing Always On/Off Flashing Off On On: Zigbee module is enabled and working. Off: Zigbee module is not enabled or not working. Zigbee module is transmitting or receiving data. On: Wifi module is enabled and working. Off: Wifi module is not enabled or not working. Wifi module is transmitting or receiving data. On: 3G/4G module is enabled and working. Off: 3G/4G module is not enabled or not working 3G/4G module is transmitting or receiving data. Power off. Power on. Before sending or exchanging Gateway for repair, please power on the gateway and press Reset button 0 seconds to reset the Gateway. Reset the gateway to purge all setting data, but TF card will not be reset. RS485 (G A+ B-) TX-LED RX-LED Use the RS485 (Modbus protocol) matching connector to connect to an external device, and when the data is sent, the TX-LED blinks. When data is received, the RX-LED blinks. SIM slot Use standard mobile SIM card to insert SIM card slot. TF slot Using standard TF memory card. LAN One RJ-45 0/00Mbps Auto-MDIX ports for connecting to either 0Mbps or 00Mbps Ethernet connections. WAN In the Gateway router, there is an RJ-45 0/00Mbps Auto-MDIX port for the WAN that connects to the XDSL/cable modem for Internet connectivity. Power (L N) Plug the power cable to this power jack.

11 GATEWAY HARDWARE CONFIGURATION AND PARAMETERS 04 Rear panel 03 Front panel 4..3 Rear panel 04 Zigbee-SMA Using 2.4G passive indoor antenna with SMA male head, the typical antenna gain is 5dBm. Wifi-SMA Using 2.4G passive indoor antenna with SMA male head, the typical antenna gain is 5dBm. This antenna parameter can be the same as that of the ZigBee antenna. 3G/4G -SMA Using 3G or 4G wireless module indoor antenna with SMA male head, the typical antenna gain is 5 dbm. Temperature/humidity sensor module interface (In figure left bottom side) used to connect an external temperature and humidity sensor.

12 2 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 4 Gateway hardware configuration and parameters 4.2 Detailed specifications Table 4:Hardware platform Processor System memory Compact flash memory Real time clock battery Value 32 bit embedded MCU 28 MB 256 MB Supper capacity Table 5:Power supply Power supply type High power supply (AC) High power supply (DC) Low power supply (DC) Power range V AC V DC V DC Maximum power consumption 0 W 0 W 0 W Table 6:Hardware interface SIM card slot TF card slot RJ-45 port LAN RJ-45 port WAN RS485 port 3G/4G port Wifi port Zigbee port Integrated temperature sensor LED indication Number 6 Comment Standard size Support up to 32G By default is 3G, and provide extension wire as option Provide extension wire as option Provide extension wire as option C Powersupply, Wifi, 3G/4G, Zigbee, RS485- (TX, RX) Table 7:Operation system Operating system Value Linux

13 TECHNICAL DATA 3 5 Technical data Table 8:Environmental condition Low temperature operating High temperature operating Storage temperature Humidity (damp Heat, cyclic) Value -40 C, 6 h +70 C, 6 h -40 C, 6 h;+85 C, 6 h Humidity >93%, 55 C, 6 cyclic (44 h) Reference IEC IEC IEC IEC IEC Table 9:Power supply Auxiliary voltage Aux. voltage interruptions Reference According to IEC According to IEC Table 0:IP class IP Value 52 Table :Insulation tests Dielectric tests Impulse voltage test Insulation resistance measurements Protective bonding resistance Value 2 kv, 50 Hz, min 500 V, 50 Hz, min, communication 5 kv,.2/50 μs, 0.5 J kv,.2/50 μs, 0.5 J, communication >00 MΩ, 500 VDC <0. Ω, 20 A, 60 s Reference IEC IEC IEC IEC Table 2:Mechanical tests Value Reference Requirement Vibration tests (sinusoidal) Response, endurance IEC Class Shock and bump test Response, withstand, bump IEC Class Table 3:Response time test Response time for device updating data to cloud server value Minimum time <20 s

14 4 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 5 Technical data Table 4: Electromagnetic compatibility tests Radiated emission test Conducted emission test Electrostatic discharge test Radiated electromagnetic field immunity test Fast transient disturbance test Surge immunity Communication test Other ports Conducted immunity test Contact discharge 8 kv Air discharge 5 kv 0 V/m Value 30 MHz 6 GHz 50 KHz 30 MHz 2 kv 4 kv 4 kv 2 kv 2 kv 4 kv 50 khz 80 MHz 0 V Power frequency (50 Hz) magnetic field immunity test Impulse magnetic field immunity 00 A/m continuous 60 s,000 A/m for...3 s 000 A/m test Damped oscillatory magnetic field immunity test Voltage dips and short interruptions Slow damped oscillatory wave 00 A/m, 000 KHz, MHz 2 s 40% for 0.2 s 70% for 0.5 s 0% for 0. s immunity test Differential mode kv Common mode 2.5 kv Ripple on auxiliary power supply Power supply port 5% U port tests Table 5:EMC compliance Communication Powersupply Earthing port Line-to-earth Line-to-line Line-to-earth Requirement Reference IEC :203 CISPR : 2009+A: 200 IEC : 203 CISPR 22: 2008 IEC : 203 IEC : 2008 IEC : 203 IEC : 2006 IEC : 203 IEC : 202 IEC : 203 IEC : 2005 IEC : 203 IEC : 2008 IEC : 203 IEC : 2009 IEC : 203 IEC : 200 IEC : 203 IEC : 200 IEC : 203 IEC : 2004 IEC : 2000 IEC : 203 IEC : 2006+A: 200 IEC :203 IEC :999+A: 200+A2:2008 Complies with the EMC directive Standards Reference 2004/08/EC EN /4, EN 60950, EN Class A Table 6:EMC compliance Complies with the LV directive Standards Reference 2006/95/EC EN /27 Table 7:ROHS compliance Complies with the RoHS directive Reference 2002/95/EC

15 CONFIGURATION 5 6 Configuration 05 Web HMI Login 06 Status Overview 07 Status Firewall 08 Status Routes 6. Login. Plug the power cable to the power supply socket, power LED will light up. 2. Connect the Ethernet to the LAN port of the gateway. LAN LED will light up. 3. Use Internet Explorer 9.0 or above internet browser. Enter IP address (the factory-default IP address setting) to the URL web address location. 4. Login the Web HMI, with the default username root and leave the password blank Firewall MyRemoteCare gateway provides basic firewall functions that filter out network packets using a set of configurable rules. The firewall status detail can be found in following operation system official site link: https: //openwrt.org/docs/guide-user/ firewall/firewall_configuration 05 Set the password at first login Status 6.2. Overview This page shows device information, including the software version, the status of memory, network, DHCP leases, wireless, and associated stations Routes This page shows the status of routing IP information and the external devices that are being connected to the Gateway. There is an AUTO REFRESH button at the top right corner of the webpage. When it is ON, the webpage will be refreshed automatically. 08

16 6 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 6 Configuration 09 status - System log 0 status Application log status Processes (default) 2 status Real time graphs The IPv4-Addresses and MAC addresses shown in figure are not default addresses. They are from devices that are being connected to the gateway System log This page shows logs of Gateway system status and all the events. System logs contain conditions of device drivers, users login and logout information, system modifications, and Wi-Fi connection information. The format of system log is: serial number, time, user name, and log information Processes This page shows an overview of system processes and their status. Processes description Procd: Processes management Kthreadd, kworker: Thread service Ksoftirqd: Bridge service Writeback: Data storage service Ntpd: Time syn. service Crontabs: Schedule task service Uhttpd, rpcd, Luci: Web service Dhcpd: DHCP service DHCP Ubus: Processes communication service Pppd: Dial-up service Hostapd: Wifi hotspot service Busybox: System command box App: Gateway application Abblog: Log service Application log This page shows status of the gateway operations, status of system applications, and all other events. Application logs contain application running and connection status. In the logging message, Read Code 0 means normal; and any non-zero value is abnormal Real-time graphs This page shows real-time information including load graphs, network traffic, wireless power, and connection status. The format of application log is: serial number, time, and log information. 0 2

17 CONFIGURATION 7 3 System System 4 System Administration 5 System Backup / Restore 6 System Flash new firmware image 7 System Flash new firmware image Flash firmware 6.3 System 6.3. System This page shows system information including Gateway hostname, time zone, language, and log settings Backup/Flash Firmware Backup/Restore This page is where configuration backup and firmware update can be performed. To back up current configuration, click on Generate Archive. To reset firmware to its initial state, click on Perform Reset. Note that the reset firmware can only work with squashfs images Flash new firmware image Administration The system administration page includes the user password settings. Passwords are settable and password must be at least 5 characters, and the maximum number of characters is 64. The following characters are accepted: Numbers 0-9 Letters a-z, A-Z Space Special characters! "#%&'( )*+ -./:;<=>?@[\]^_`{ }~ etc 6 Flash new firmware image process. Select new system firmware image 2. Click "Flash Image" to bring up following page Click Proceed to update system, Click Cancel to cancel the update. 4. When updating is finished, the gateway will auto reboot.

18 8 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 6 Configuration 8 System Flash new application image 9 System Flash new application image Flash firmware 20 System Reboot 2 Gateway Gateway 22 Gateway Gateway basic configuration Press and hold Reset button for 0 seconds to reset firmware to factory settings Flash new application image 6.4 Gateway 6.4. Open application configuration 8 Flash new application image process. Select new system firmware image. 2. Click "Flash Image" to bring up following page Gateway basic configuration This page is where Modbus templates management and gateway property settings can be performed Click Proceed to update system, Click Cancel to cancel the update. 4. When updating is finished, the gateway will auto reboot. When update is fail, system will automatic restored to previously version. Press and hold Reset button for 0 seconds to reset firmware to factory settings Reboot Software reboot

19 CONFIGURATION 9 23 Gateway Equipment 24()Gateway Modbus 24(2)Gateway Modbus Equipment This page is used to build the structure of the monitoring equipment. To add a new switchgear in the structure:. Click on Add New Switchgear, then click on the newly added switchgear to enter or edit its properties. 2. Under the newly created switchgear, click on Add New Circuit Breaker, and then click on the newly created circuit breaker to enter or edit its properties. 3. To add more circuit breakers to the switchgear, repeat step 2. Add Monitoring Device to switchgear by clicking on Add New M&D, and then click on the newly created monitoring device to enter or edit its properties After configuring the Modbus point list, user can configure data collecting logic that tells gateway how to collect and send data to MyRemoteCare server. Currently, MyRemoteCare gateway supports two rules.. Auto update: Collect and send data periodically to server with a predefined interval. User can add or remove a list of Modbus registers to this rule so that data collected from these Modbus registers shall be sent to server periodically. 2. Update by Events: This rule will trigger and send data to server when a specific event occurs. User can add or remove list of Modbus registers (or range of Modbus registers) to this rule so that data read from those Modbus registers shall be sent to server when certain conditions hold true Modbus template This configuration page allows users to define Modbus registers template for a new monitoring device. Start register: Triggering Modbus start register End register: Triggering Modbus end register Push logic: Ascent/Desent/Changing, the triggering logic of the Modbus value Time: Polling time to check the triggering Modbus registers. Rank: The critial level of the triggering Modbus poing. (Alarm, Waring, Normal, Disconnect, Open/Close) Property: configure the Modbus register range that when the triggering happens, their values will be pushed to the server. 24 (2) 24 ()

20 20 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 6 Configuration 25 Users Edit Users Add new user 26 Users Edit users User configuration 27 Users Edit Users Users overview 28 New users option Router password 6.5 Users This user management page is used to create, edit, or delete users who can access the gateway. 25 To edit a user, click on Edit button. After user information is edited, click Save or Save and Apply for the changes to take effect. 27 The default password for the newly created user is Aa To change the default password, click on Options and enter new password. Note that password length must be from 5 to 64 characters. To add new user, click on Add New User and enter user information and click Save. 28 The following characters are accepted. Numbers 0-9 Letters a-z, A-Z Space Special characters!"#%&'( )*+ -./:;<=>?@[\]^_`{ }~ etc. 26

21 CONFIGURATION 2 29 Network interface 30 Network Wireless 3 Change the Wi-Fi SSID and password 32 Network DHCP 6.6 Network 6.6. Interfaces This page shows status and settings of all network interfaces supported by MyRemoteCare gateway. User can start or stop connection of an interface as well as edit interface settings. To change Wi-Fi SSID and password, on Network menu, select Wireless, then select Security Settings Wireless MyRemoteCare gateway provides Wi-Fi access point so that mobile devices or computers can connect and make changes to its configuration. For security purpose, the gateway shall not broadcast its SSID DHCP This page is where DHCP can be turned ON or OFF. To join the Wi-Fi, user can manually add the below hidden SSID: Table 8: Wifi default SSID and password Default SSID MRCGateway Password

22 22 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 6 Configuration Firewall The firewall creates zones over your network interfaces to control network traffic flow. Table 9: Configured default rules Name Value Default input ACCEPT Yes Set policy for the INPUT chain of the filter table. output ACCEPT Yes Set policy for the OUTPUT chain of the filter table. forward REJECT Yes Set policy for the FORWARD chain of the filter table. syn_flood Yes Enable SYN flood protection (obsoleted by synflood_protect setting). synflood_rate string No Set rate limit (packets/second) for SYN packets above which the traffic is considered a flood. synflood_burst string No Set burst limit for SYN packets above which the traffic is considered a flood if it exceeds the allowed rate. disable_ipv6 No Disable IPv6 firewall rules. Table 20: Optional rules Name Value Default Name string Yes Setting current rule s name. target string Yes Firewall action (ACCEPT, REJECT, DROP, MARK, NOTRACK) for matched traffic. src string No Specifies the traffic source zone. Must refer to one of the defined zone names. For typical port forwards this usually is wan. src_ip string No Match incoming traffic from the specified source ip address. src_mac string No Match incoming traffic from the specified mac address. src_port string No Match incoming traffic originating from the given source port or port range (ex: ' ') on the client host. proto string No Match incoming traffic using the given protocol. Can be one of tcp, udp, tcpudp, udplite, icmp, esp, ah, sctp, or all or it can be a numeric value, dest representing one of these protocols or a different one. A protocol name from /etc/protocols is also allowed. The number 0 is equivalent to all. string No Specifies the traffic destination zone. Must refer to one of the defined zone names. For DNAT target on Attitude Adjustment, NAT reflection works only if dest_ip this is equal to lan. string No Match incoming traffic directed to the specified destination ip address. With no dest zone, this is treated as an input rule! dest_port string No Match incoming traffic directed at the given destination port or port range (ex: '5000:500', port range does not apply to all protocols), if relevant proto is specified. Multiple ports can be specified like ' '. family string No Protocol family (ipv4, ipv6 or any) to generate iptables rules for. Gateway firewall factory default communication protocols as below. Allowed protocols: DHCP, PING, IGMP, MLD, IPsec-ESP, ISAKMP DHCP: Gateway dynamic allocate IP PING: Check connection status IGMP, MLD: Managing multiple broadcast IPSec-ESP: Provide security service for IPv4 and IPv6 ISAKMP: Security connection and key management

23 CONFIGURATION Network Firewall 34 Network Diagnostics 35 Logout It is recommended that user shall not change the default settings to the firewall. It was set as it is required for the Application to run in the Gateway. Detailes of Firewall configuration can be found at below link: wall/firewall_configuration Diagnostics This page is used for network diagnostics Logout Log off the system 35 33

24 24 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 7 Complete Gateway and accessory ordering information The order number consists of a string of codes generated from the Gateway's hardware and software modules. Use the ordering key information to generate the order code when ordering complete Gateway. 7. Order code information Table 2:Gateway order code information Digit Product type Product name Application country Power supply Application A-9 environment Hardware interface Protection option Revision Reverse Antenna TF card option* Range A-9 A-9 A-9 A-9 A-9 -Z A-9 A-9 A-9 Key G A CN US EU SA AU 2 A B N A B N A N A B C Order code: GateWay MyRemoteCare GateWay China USA Europe Saudi Australia 0 V~220 V AC/DC 24 V~48 V DC Indoor application Outdoor application None 2/3G 2/3/4G Standard With conformal coating Product version.0 SMA Rubber Antenna, 5 DB.5m wire Magnets Holding Solenoid SMA Antenna, 5 DB 3m wire Magnets Holding Solenoid SMA Antenna, 5 DB No TF card 8G 6G 32G Main unit - Enclosure G A C N A A A - A G A C N A A - A * To store data locally in the Gateway device, for configuration of 32 M&D devices with 50 historic properties for each devices, and Pooling interval 5 mins, it will consume around 8 GB storage per year.

25 UNPACKING, INSPECTION AND STORING 25 8 Unpacking, inspection and storing 8. Removing transport packing Gateways require careful handling.. Examine the delivered products to ensure that they have not been damaged during the transport. 2. Remove the transport packing carefully without force. The cardboard packaging material is 00% recyclable. 8.2 Inspecting the product 8.2. Identifying the product. Locate the Gateway's order number from the label on top of the plug-in unit. 2. Compare the Gateway's order number with the ordering information to verify that the received product is correct Checking delivery items Check that all items are included in the delivery in accordance with the delivery documents Inspecting the Gateway Gateways require careful handling before installation on site. Check the Gateway to see if any damage occurred during transportation If the Gateway has damaged during transportation, make a claim against the transport contractor, and notify the local ABB representative Returning a Gateway damaged in transit If damage has occurred during transport, appropriate actions must be taken against the latest carrier. Please inform the nearest ABB office or representative. Notify ABB immediately if there are any discrepancies in relation to the delivery documents. 8.3 Storing If the Gateway is stored before installation, it must be done in the original transport packaging in a dry and dust free place. Observe the environmental requirements stated in the technical manual.

26 26 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL 9 Mounting 36 Gateway dimension upward view 37 Gateway dimension front view 38 Gateway linear guide installation Bottom view 9.3 Checking environmental conditions and mounting space The mechanical and electrical environmental conditions at the installation site must be within the limits described in the technical manual. Avoid installation in dusty, damp places Avoid places susceptible to rapid temperature variations, powerful vibrations and shocks, surge voltages of high amplitude and fast rise time, strong induced magnetic fields or similar extreme conditions. Check that sufficient space is available Sufficient space is needed at the front and rear of the Gateway to allow access to wires and to enable maintenance and future modifications. 9.2 Dimension

27 REMOVING, REPAIRING AND EXCHANGING/GLOSSARY 27 0 Removing, repairing and exchanging 0. Checking Gateway information The Gateway information includes detailed information about the hardware and software, such as version and serial number. The Gateway information is shown on the housing label. 0.4 Exchanging the Gateway To exchange the Gateway with another identical unit, remove the Gateway and install the new one. To exchange a Gateway to a different unit, ask the support from your local ABB. 0.2 Removing the Gateway Before removing the Gateway, please turn off the power and disconnect the corresponding wiring. Please refer to the installing section for the detailed information. 0.3 Sending the Gateway for repair In case of product problem, contact the nearest ABB or representative for consultation and instructions. Before sending or exchanging Gateway for repair, please press Reset button 0 seconds to reset the Gateway. Reset the gateway to purge all sensitive data. Before sending or exchanging Gateway for repair, please properly handle the TF card to ensure data security. Glossary EMC IEC MRC Electromagnetic compatibility International Electrotechnical Commission MyRemoteCare

28 28 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL

29 29

30 30 ABB Ability TM Asset Health for Electrical Systems PRODUCT MANUAL Copyright This document and parts thereof must not be reproduced or copied without written permission from ABB, and the contents thereof must not be imparted to a third party, nor used for any unauthorized purpose. The software or hardware described in this document is furnished under a license and may be used, copied, or disclosed only in accordance with the terms of such license. Trademarks ABB and ABB AbilityTM are registered trademarks of ABB Group. All other brand or product names mentioned in this document may be trademarks or registered trademarks of their respective holders. Guarantee Please inquire about the terms of guarantee from your nearest ABB representative.

31 3

32 ABB Xiamen Switchgear Co., Ltd. ABB Industrial Park, Torch High-Tech Zone, No. 39, Xiamen, Fujian, P.R.China Tel: Fax: Zip Code: Service HotLine: Copyright 208 ABB. All rights reserved. We reserve the right to make changes in the course of technical development. Publication No: YHA Rev. A, en

Document ID: 1VCD Product Name: MyRemoteCare Gateway Document Name: Operation Manual Issued: Revision: R0001 Product Version: 1.

Document ID: 1VCD Product Name: MyRemoteCare Gateway Document Name: Operation Manual Issued: Revision: R0001 Product Version: 1. Document ID: 1VCD601158 Product Name: Document Name: Operation Manual Issued: 2012-06-15 Revision: R0001 Product Version: 1.0 Copyright 2012 ABB. All rights reserved Copyright This document and parts thereof

More information

Communication Gateway COM 610. Product Guide

Communication Gateway COM 610. Product Guide Communication Gateway COM 610 Product Guide Issued: September 2004 Status: Updated Version: D/17.10.2006 Data subject to change without notice Features Protocol conversion gateway for substation automation:

More information

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This

More information

Manual Version: V1.00. Video Decoder Quick Guide

Manual Version: V1.00. Video Decoder Quick Guide Manual Version: V1.00 Video Decoder Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Panoramic Power Installation and configuration guide

Panoramic Power Installation and configuration guide Panoramic Power Installation and configuration guide Advanced 4th generation Bridge for firmware v259 Version 1 1 Copyright notice Copyright 2017 Panoramic Power Ltd. All rights reserved. Panoramic Power

More information

Arc protection relay. Features Three-phase overcurrent function. Application

Arc protection relay. Features Three-phase overcurrent function. Application Arc protection relay REA 10_ Page 1 Issued: May 1999 Status: New Data subject to change without notice Features Three-phase overcurrent function Loop-type or radial sensor fibre for arc detection Two high-speed

More information

Relion 611 series. 611 series Type Test Certificate

Relion 611 series. 611 series Type Test Certificate Relion 611 series 611 series Document ID: 1MRS757466 Issued: 2016-02-22 Revision: B Product version: 2.0 Copyright 2016 ABB. All rights reserved Table of contents Table of contents Section 1 Section

More information

MINER-S Station Controller. Substation Automation

MINER-S Station Controller. Substation Automation Substation Automation MINER-S Station Controller incorporates traditional RTU functions with new technology in a compact design MINER-S Station Controller combines the functions of a traditional RTU with

More information

RER 123 Bus Connection Module. Technical Description

RER 123 Bus Connection Module. Technical Description Bus Connection 1MRS751143-MUM Issued: 06.11.1998 Version: E/08.07.2005 Bus Connection 1. About this manual...4 1.1. Copyrights...4 1.2. Trademarks...4 1.3. Guarantee...4 2. Safety information...5 3. General...6

More information

MINER-S Station Controller

MINER-S Station Controller MINER-S Station Controller Substation Automation MINER-S Station Controller The MINER-S Station Controller is a SCADA enabled fixed point remote terminal unit (RTU) with a data concentrator, event reporter,

More information

Motor Control and Protection Unit M10x AO Module User Guide

Motor Control and Protection Unit M10x AO Module User Guide Motor Control and Protection Unit M10x AO Module User Guide The information in this document is subject to change without notice and should not be construed as a commitment by ABB. ABB assumes no responsibility

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide DL-200 Cellular Data logger V1.2_201610 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 4 1.1 CONTENTS LIST... 5 1.2 HARDWARE INSTALLATION... 6 1.2.1 WARNING... 6 1.2.2 SYSTEM REQUIREMENTS...

More information

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB MO-067-EN Operation Manual MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB Transformer Substations Secondary Distribution Switchgear Primary Distribution Switchgear Protection

More information

Mini Energy Web Server

Mini Energy Web Server 87045 LIMOGES Cedex Telephone : 05 55 06 87 87 Fax: 05 55 06 88 88 Mini Energy Web Server Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Type VRLTC tap changer

Type VRLTC tap changer Report No. 1ZUA938502-AGC 2, Rev 0 Date: 6 November 2012 Type VRLTC tap changer Ruggedized electronics systems specification & type test data Product Style No Rating By Type VRLTC, on-tank, vacuum reactance

More information

Quick Start M!DGE / MG102 Wireless Router 6/13/2017

Quick Start M!DGE / MG102 Wireless Router 6/13/2017 6/13/2017 1. Welcome Thank you for buying M!DGE / MG102 Wireless Router from RACOM. Please read this Quick Start Guide carefully since it contains important security notes (section 2) and compliance information

More information

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN Highlights & Features Full corrosion resistant Aluminium chassis Suitable for 24V system up to 40A Built-in diagnostic monitoring for DC OK, Discharge and Battery Fail by relay contacts LED indicator for

More information

Scout-S Station Controller

Scout-S Station Controller Scout-S Station Controller Substation Automation Scout-S Station Controller The Scout-S Station Controller is a SCADA enabled remote terminal unit (RTU) with a data concentrator, event reporter, and built-in

More information

Arc protection relay. Features Three-phase overcurrent function. Application

Arc protection relay. Features Three-phase overcurrent function. Application Arc protection relay REA 10_ Issued: May 1999 Status: Updated Version: B/12.11.2001 Data subject to change without notice Features Three-phase overcurrent function Loop-type or radial sensor fibre for

More information

Camera A14 and A34 Dome Camera

Camera A14 and A34 Dome Camera Camera A14 and A34 Dome Camera Quick Start Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. About This Manual: This manual

More information

CPU6501 REV1.0 1 WILLOWGLEN MSC BERHAD

CPU6501 REV1.0 1 WILLOWGLEN MSC BERHAD CPU6501 REV1.0 1 RESPONSIBLE PERSON REVISION RELEASE DATE COMPOSER JOB TITLE APPROVALS JOB TITILE 0.0 10 th MAR 2016 SIDEK MANAGER NIK AZLAN CTO 1.0 26/10/2016 Farm Zheng Lin HW Engineer Mohd Sidek HW

More information

FL MC 2000E (SM40) LC

FL MC 2000E (SM40) LC IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features

More information

Earth-fault Relay SPAJ 110 C. Product Guide

Earth-fault Relay SPAJ 110 C. Product Guide Issued: April 1999 Status: Updated Version: C/12.04.2006 Data subject to change without notice Features Low-set neutral overcurrent stage with definite time or inverse time characteristic High-set neutral

More information

A-300 Speed Dome. Quick Start Guide

A-300 Speed Dome. Quick Start Guide A-300 Speed Dome Quick Start Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the company you purchased the unit from. This manual

More information

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Type MVTT 14 and MVTT 15: Static Digital Time delay relays Type MVTT 4 and MVTT 5: Static Digital Time delay relays Features 000/ setting range Time settings easily selected by means of thumbwheel switches Provide time delayed pick-up, or drop-off Compact construction

More information

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide Combined Overcurrent and Earth-fault Product Guide Issued: April 1999 Status: Updated Version: C/18.04.2006 Data subject to change without notice Features Three-phase, low-set phase overcurrent unit with

More information

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide Issued: April 1999 Status: Update Version: C/12.04.2006 Data subject to change without notice Features Sensitive low-set neutral overcurrent stage with definite time characteristic High-set neutral overcurrent

More information

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Card Enrollment Station. User Manual UD05870B

Card Enrollment Station. User Manual UD05870B Card Enrollment Station User Manual UD05870B User Manual 2017 Hangzhou Hikvision Digital Technology Co., Ltd. This manual is applied for D8E series card enrollment station. It includes instructions on

More information

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A)

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A) Modem/Router INSTRUCTION MANUAL (M179B01-03-17A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could result in personal injury

More information

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice Issued: July 1998 Status: Revised Version: C/08.10.2003 Data subject to change without notice Features Comprehensive voltage regulation for power transformers with on-load tapchangers in distribution substations

More information

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault Issued: April 1999 Status: Updated Version: B/09.11.2001 Data subject to change without notice Features Sensitive restricted earth-fault protection stage for fast, selective earth-fault protection Sensitive

More information

Installation and commissioning manual Waveguide Access Point WGA631

Installation and commissioning manual Waveguide Access Point WGA631 Waveguide Access Point WGA631 Document ID: 1MRS755551 Issued: 23.06.2009 Revision: B Product version: 1.1 Copyright 2009 ABB. All rights reserved Copyright This document and parts thereof must not be

More information

Safety Standards. Model Number:

Safety Standards. Model Number: LNP-C Highlights & Features Constant current design Input voltage from 198-264Vac Up to 90.5% efficiency Independent type Meets IEC/EN 61000-3-2, Class C Fixed output current IP20 assembly for indoor applications

More information

User Guide. 300Mbps Wi-Fi Range Extender MW300RE REV

User Guide. 300Mbps Wi-Fi Range Extender MW300RE REV User Guide MW300RE REV3.0.0 1910080035 COPYRIGHT & TRADEMARK Specifications are subject to change without notice. is a registered trademark of MERCUSYS TECHNOLOGIES CO., LTD. Other brands and product names

More information

extending the boundaries of technology evolution of proven technology FEATURES

extending the boundaries of technology evolution of proven technology FEATURES extending the boundaries of technology evolution of proven technology FEATURES IEC 61850 compliant Advanced AC capabilities with comprehensive fault detection Integrated protection functions Disturbance

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits. UC-8100 Series Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports Features and Benefits Armv7 Cortex-A8 300/600/1000 processor Dual auto-sensing 10/100 Mbps Ethernet

More information

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter

RuggedMC RMC40 RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. 4-Port Ethernet Media and Speed Converter Features and Benefits 4-Ethernet Ports with Optional Dual Fiber Optics Three configurations to choose from: z2 10/100TX ports + 1 100FX port (SC/ST) z2 10/100TX ports + 2 100FX port (MTRJ/LC) z4 10/100TX

More information

IR Network Speed Dome

IR Network Speed Dome IR Network Speed Dome Quick Guide Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. This manual applies to IR High-Definition

More information

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP

QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP QUICKSTART Smart EnOcean Gateway DC-GW/EO-IP Digital Concepts GmbH 27.07.2016 Contents 1. Introduction... 3 2. Functionality... 4 3. Package Contents... 4 4. Requirements... 5 5. Ports... 5 6. Mounting...

More information

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016

INGEPAC DA-CU. Control Unit. Data Sheet ZY8932IMA01E 31/03/2016 ZY8932IMA01E 31/03/2016 INGEPAC DA-CU Control Unit Data Sheet Total or partial reproduction of this publication by any means or procedure is prohibited without previous express written authorisation by

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

Remote I/O RIO600 Product Guide

Remote I/O RIO600 Product Guide Product Guide Contents 1. Description...3 2. Design...3 3. Configuration examples...4 4. Self-supervision...5 5. Communication...5 6. Indication LEDs...5 7. Technical data...6 8. Connection and terminal

More information

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION Series G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router FEATURE HIGHLIGHTS GPRS/G/4G Cellular Protocol Gateway with extensive LTE Band support: EU Model: 2100/1800/850/2600/900/800MHz

More information

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter EM132 MULTI-FUNCTION TRANSDUCER SATEC EM132 is a Smart DIN Rail Multi-Function Transducer with a local display. It is based on SATEC s best seller PM130 PLUS with an off-the-shelf LCD display (similar

More information

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300

SPA-ZC 302. Profibus-DPV1/SPA Gateway. Product Guide. spa-zc302_rightco300 Profibus-DPV1/SPA Gateway SPA-ZC 302 Product Guide spa-zc302_rightco300 Issued: 25.11.2003 Status: Updated Version: D/16.05.2008 Data subject to change without notice Features Profibus DP Version 1 connectivity

More information

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015)

SMM Series 3G and GSM Modems. Quick Start Guide. Document Number: Version: 1.2 (20 October, 2015) SMM Series 3G and GSM Modems Quick Start Guide Document Number: 0013-001-000272 () Documentation Control Generation Date: October 20, 2015 Cybertec Pty Limited All rights Reserved. No part of this publication

More information

DARK1616M DANTE NETWORK AUDIO 16 INPUT 16 OUTPUT AES3 & MIC/LINE LEVEL ANALOGUE INTERFACE PRODUCT DETAILS

DARK1616M DANTE NETWORK AUDIO 16 INPUT 16 OUTPUT AES3 & MIC/LINE LEVEL ANALOGUE INTERFACE PRODUCT DETAILS DARK1616M DANTE NETWORK AUDIO 16 INPUT 16 OUTPUT AES3 & MIC/LINE LEVEL ANALOGUE INTERFACE PRODUCT DETAILS 6 BROOKS PLACE, MAIDSTONE, KENT, ME14 1HE. ENGLAND. TEL: +44 (0) 1622 753662 Visit our Website

More information

AM4000D Outdoor CPE User Manual

AM4000D Outdoor CPE User Manual AM4000D Outdoor CPE User Manual Page 1 Table of contents 1. OVERVIEW... 4 1.1. USER INTERFACE SPECIFICATION... 4 1.2. LTE INTERFACE SPECIFICATION... 4 2. GETTINGSTARTED... 4 2.1. PACKING LIST AND CPE UNIT...

More information

Manual Version: V1.00. Video Decoder User Manual

Manual Version: V1.00. Video Decoder User Manual Manual Version: V1.00 Video Decoder User Manual Thank you for purchasing our product. If there are any questions, or requests, please do not hesitate to contact the dealer. Copyright Copyright 2016 Zhejiang

More information

Industrial 3-Port Fast Ethernet Media Converter Switches

Industrial 3-Port Fast Ethernet Media Converter Switches Industrial 3-Port Fast Ethernet Media Converter Switches KSD-103-A series KSD-103-B series Installation Guide DOC.081111 1/20 (C) 2008 KTI Networks Inc. All rights reserved. No part of this documentation

More information

MySiteCare Operation manual

MySiteCare Operation manual Medium voltage service (Rev. 5.3) MySiteCare Operation manual Table of contents Copyright 2 Disclaimer 2 Conformity 3 Safety Information 3 1. Introduction 4 2. Environmental aspects 6 3. MySiteCare overview

More information

JOVISION. Home Security IP Camera. Quick Start Guide

JOVISION. Home Security IP Camera. Quick Start Guide JOVISION Home Security IP Camera Quick Start Guide Statement Thank you for choosing Jovision, this user manual is intended for users of HD Wireless IP Camera. It includes instructions on how to use the

More information

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE INSTALLATION INSTRUCTIONS Revision B1 Rapid City, SD, USA, 05/2009 MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE BE SURE POWER IS DISCONNECTED PRIOR TO INSTALLATION! FOLLOW NATIONAL, STATE AND LOCAL CODES.

More information

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O Characteristics StarDelta Timing Relay 0.05s 300h 24 240V AC/DC 2C/O Main Range of product Product or component type Discrete output type Device short name Nominal output current Zelio Time Modular timing

More information

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options

RuggedMC RMC RUGGEDCOM ISO 9001 REGISTERED. Features and Benefits. Ethernet Media Converter (Copper to Fiber) Universal Power Supply Options Features and Benefits The RuggedMC is an industrially hardened fiber optical media converter specifically designed to operate in harsh environments such as those found in electric utility substations and

More information

LTK1100 Series Card Reader User Manual

LTK1100 Series Card Reader User Manual LTK1100 Series Card Reader User Manual User Manual About this Manual This Manual is applicable to Card Reader. The Manual includes instructions for using and managing the product. Pictures, charts, images

More information

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1A Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage and full power up to 55 C Power will not de-rate for the entire input voltage range

More information

Installing and Configuring Rialto Analytic Appliances

Installing and Configuring Rialto Analytic Appliances Installing and Configuring Rialto Analytic Appliances Important Safety Information This manual provides installation and operation information and precautions for the use of this camera. Incorrect installation

More information

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A

Z-Wave 4-in-1 Multi Sensor HZS-300E/HZS-300A Copyright Z-Wave 4-in-1 Multi Sensor Copyright 2015 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system,

More information

UTAH-100/XHDA SERIES

UTAH-100/XHDA SERIES Utah Sandar AS User Manual & Installation Guide UTAH-100/XHDA SERIES SD & HD3G Digital Distribution 1:4 & 1:8 CONTENTS CONTENTS... 2 INTRODUCTION... 3 WARRANTY... 3 DOCUMENT REVISION HISTORY... 3 SAFETY

More information

Quick Start M!DGE / MG102 Wireless Router 11/16/2011

Quick Start M!DGE / MG102 Wireless Router 11/16/2011 11/16/2011 1. Welcome Thank you for buying M!DGE / MG102 Wireless Router from RACOM. Please read this Quick Start Guide carefully since it contains important security notes (section 2) and compliance information

More information

Home Automation Gateway HA102

Home Automation Gateway HA102 USER MANUAL Home Automation Gateway HA102 TABLE OF CONTENTS 1. IMPORTANT SAFETY INFORMATION... 4 2. DEVICE DESCRIPTION... 5 3. INSTALLATION OF THE SCHWAIGER GATEWAY... 6 3.1 WIFI CONFIGURATION OF THE

More information

Control Panel CP600-eCo CP604, CP604-B

Control Panel CP600-eCo CP604, CP604-B DATA SHEET Control Panel CP600-eCo CP604, CP604-B 1 Ordering Data Part No. Description Product Life Cycle Phase 1SAP504100R0001 CP604, control panel, TFT graphical display, single-touch screen, 4.3, Active

More information

Features and Benefits. SNMP MIB-II for network management. Certifications

Features and Benefits. SNMP MIB-II for network management. Certifications NPort 5600-DT Series 8-port RS-232/422/485 serial device servers Features and Benefits 8 serial ports supporting RS-232/422/485 Compact desktop design 10/100M auto-sensing Ethernet Easy IP address configuration

More information

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box

TM7BDM8B. Main. Enclosure material. Input/output number 8 Input/output number of splitter box Product datasheet Characteristics TM7BDM8B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 8 Input/output number of splitter

More information

Feeder protection relay SPAA 121 C. Product Guide

Feeder protection relay SPAA 121 C. Product Guide Issued: April 1999 Status: Updated Version: C/06.03.2006 Data subject to change without notice Features Two-phase low-set phase overcurrent unit with definite time or inverse time characteristic Two-phase

More information

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box

TM7BDI16B. Main. Enclosure material. Input/output number 16 Input/output number of splitter box Product datasheet Characteristics TM7BDI16B Main Range of product Product or component type Range compatibility Enclosure material Bus type System Voltage Input/output number 16 Input/output number of

More information

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications Power Circuit Control Circuit (External Source) Control Circuit (Internal Source) Short Circuit Current Rating (SCCR) Application Electrical Ratings Three-phase Number of Poles 3 Input Power Terminals

More information

WIFI EXTENDER User Manual

WIFI EXTENDER User Manual WIFI EXTENDER User Manual READ CAREFULLY and DO NOT PANIC version 1.0 www.yachtrouter.com CONTENTS 1. COPYRIGHT NOTICE... 3 2. RoHS COMPLIANT... 3 3. INTRODUCING YACHT ROUTER SOLUTION... 3 4. DISCLAIMER...

More information

Features and Benefits. Certifications

Features and Benefits. Certifications UC-5100 Series Arm-based Industrial computing platform for industrial automation Features and Benefits Armv7 Cortex-A8 1000 MHz processor Dual auto-sensing 10/100 Mbps Ethernet ports 4 software-selectable

More information

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications

Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA. Features and Benefits. Certifications IA260 Series Arm-based DIN-rail industrial computers with 4 serial ports, 2 LAN ports, 8 DI/DO, and VGA Features and Benefits Cirrus Logic EP9315 Arm9 CPU, 200 MHz 128 MB RAM onboard, 32 MB flash disk

More information

NetCom Plus 411 (NetCom 411, NetCom 411 PRO)

NetCom Plus 411 (NetCom 411, NetCom 411 PRO) VS Vision Systems GmbH / Part Number 6670 Main Features Ethernet to serial 4 port RS232 Virtual Com Port driver for Windows Secure Server with latest SSL/AES-256 encryption Operation in Driver Mode, TCP/IP

More information

TEW-211BRP. Wireless AP Router. User s Manual

TEW-211BRP. Wireless AP Router. User s Manual TEW-211BRP Wireless AP Router User s Manual Version 1.4 - Jan 2002 CONTENTS Introduction...3 Hardware Installation...5 General Wireless AP Router System Connection...6 Wireless AP Router Default Settings

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

TM241CE24T controller M IO transistor PNP Ethernet

TM241CE24T controller M IO transistor PNP Ethernet Product data sheet Characteristics TM241CE24T controller M241 24 IO transistor PNP Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Inrush current

More information

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ

Chrome DIN Rail Power Supply 24V 10W 1 Phase (Class II & NEC Class 2) / DRC-24V10W1AZ Highlights & Features Protection Class II, Double Isolation (No Earth connection is required) Universal AC input voltage without power de-rating Efficiency > 80.0% @ 115Vac & 230Vac NEC Class 2 / Limited

More information

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION Series G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway FEATURE HIGHLIGHTS Extensive G and LTE Band Support - EU: 2100/1800/850/2600/900/800MHz (B1/B/B5/B7/B8/B20) - US: 1900/AWS/850/700/700/1900MHz

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

Safety Instructions WARNING Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may damage seriously the IntesisBox and/or any

More information

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009

Reference Manual EPM-PS1. PC/104-Plus Power Supply Module DOC. REV. 4/29/2009 Reference Manual DOC. REV. 4/29/2009 EPM-PS1 PC/104-Plus Power Supply Module WWW.VERSALOGIC.COM 12100 SW Tualatin Road Tualatin, OR 97062-7341 (503) 747-2261 Fax (971) 224-4708 Contents Copyright 2013

More information

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A

Z-Wave Ceiling-mount Smoke Detector HZS-200E/HZS-200A Z-Wave Ceiling-mount Smoke Detector Copyright Z-Wave Ceiling-mount Smoke Detector Copyright 2015 by PLANET Technology Corp. All rights reserved. No part of this publication may be reproduced, transmitted,

More information

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION Series G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway FEATURE HIGHLIGHTS Extensive G and LTE Band Support - EU: 2100/1800/850/2600/900/800MHz (B1/B/B5/B7/B8/B20) - US: 1900/AWS/850/700/700/1900MHz

More information

AS1008-P AS1026-P AS2008-P AS2024-P User Manual

AS1008-P AS1026-P AS2008-P AS2024-P User Manual Fast Ethernet and Gigabit Ethernet PoE+ Unmanaged Switches AS1008-P AS1026-P AS2008-P AS2024-P User Manual Version 1.0.0.1 Sep 2017 Contents Compliances and Safety Statements... 3 1. AS1000 Series Product

More information

3G WI-FI HOTSPOT USER MANUAL HHTSPT3GM42.

3G WI-FI HOTSPOT USER MANUAL HHTSPT3GM42. 3G WI-FI HOTSPOT USER MANUAL HHTSPT3GM42 www.hamletcom.com Dear Customer, thanks for choosing an Hamlet product. Please carefully follow the instructions for its use and maintenance and, once this item

More information

HD IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.0.0

HD IR Waterproof Fixed Network Camera. Quick Start Guide. Version 1.0.0 HD IR Waterproof Fixed Network Camera Quick Start Guide Version 1.0.0 Welcome Thank you for purchasing our network camera! This quick start guide is designed to be a reference tool for your system. Please

More information

C9900-P223 and C9900-P224

C9900-P223 and C9900-P224 Installation and Operating instructions for C9900-P223 and C9900-P224 Power Supply Units Version: 1.2 Date: 2012-02-22 Table of contents Table of contents 1. Foreword 2 Notes on the Documentation 2 Liability

More information

Cockpit Main Gateway Ordering Code: CKNOAD1

Cockpit Main Gateway Ordering Code: CKNOAD1 Cockpit Main Gateway Ordering Code: CKNOAD1 Table of contents 1. IMPORTANT SAFETY INFORMATION... 4 2. DEVICE DESCRIPTION... 5 3. INSTALATION OF THE COCKPIT GATEWAY... 6 3.1. WIFI CONFIGURATION OF THE

More information

Hardened Web-Smart High Power PoE Ethernet Switch

Hardened Web-Smart High Power PoE Ethernet Switch Quick Start Guide This quick start guide describes how to install and use the Hardened Web-Smart High Power PoE (Power over Ethernet) Ethernet Switch. This is the switch of choice for harsh environments

More information

DIN Rail RTU 540CMD01 Data sheet

DIN Rail RTU 540CMD01 Data sheet RTU540 product line DIN Rail RTU 540CMD01 Data sheet 4 3 RS232C RS232C RS232C or RS485 or RS485 or RS485 1 2 E1 E2 10/100 MB LAN Protocol Protocol Controller Controller MPU Cortex-A8 AM3352 Application

More information

Teslights Hybrid Lighting SCALAMAX Protocol LX-12D Gateway. Document Number: IN R01 Copyright Teslights, LLC

Teslights Hybrid Lighting SCALAMAX Protocol LX-12D Gateway. Document Number: IN R01 Copyright Teslights, LLC SCALAMAX Protocol LX-10 Series Gateways Teslights Hybrid Lighting SCALAMAX Protocol LX-12D Gateway Document Number: IN-0000033-R01 Copyright Teslights, LLC 2010-2020 Compliant Index Warning... 2 Disclaimer...

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

DS-1H05 Ethernet-over-Coax Extender. User Manual

DS-1H05 Ethernet-over-Coax Extender. User Manual DS-1H05 Ethernet-over-Coax Extender User Manual Thank you for purchasing our product. If there is any question or request, please do not hesitate to contact dealer. This manual is applicable to DS-1H05-T,

More information

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights

More information

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date: Installation- and Operating instructions for CU8880-0010 Ethernet Controller with USB Input Version: 1.4 Date: 2018-04-12 Table of contents Table of contents 1. 2. 3. 4. 5. General instructions 2 Notes

More information

OnCell G3150A-LTE Series

OnCell G3150A-LTE Series OnCell G3150A-LTE Series Rugged LTE serial/ethernet-to-cellular gateways Features and Benefits Dual cellular operator backup with dual-sim GuaranLink for reliable cellular connectivity Rugged hardware

More information

LCD Micro Ethernet Interface Module for Alpha LCD Panels

LCD Micro Ethernet Interface Module for Alpha LCD Panels LCD Micro Ethernet Interface Module for Alpha LCD Panels IES-ABB-ETHERNET-01 Product Overview The IES-ABB-ETHERNET-01 module provides a simple means of connecting any Ethernet (10Base-T) network to a Liquid

More information