Compact PLC for STEP7 from Siemens PLC-CPU for STEP7 from Siemens Order no. Type VIPA 214-1BA02 CPU 214 VIPA 214-1BC02 CPU 214C VIPA 215-1BA02
|
|
- Randolf Wilkinson
- 5 years ago
- Views:
Transcription
1 PLC-CPU - VIPA -1BA02 CPU VIPA -1BC02 CPU C VIPA -1BA02 CPU VIPA -1BA02 CPU Load memory (kb) C OB1/10/20/35/40//82/85/86/100/121/122 MPI: RS
2 PLC-CPU - with serial interface VIPA -2BS02 VIPA -2BS12 VIPA -2BS32 VIPA -2BS02 VIPA -2BS12 VIPA -2BS32 VIPA -2BS02 VIPA -2BS12 VIPA -2BS32 CPU SER CPU SER CPU SER CPU SER CPU SER CPU SER CPU SER CPU SER CPU SER 2 additional standard RS232 interfaces Load memory (kb) OB1/10/20/35/40//82/85/86/100/121/122 MPI: RS5 Communication Data Interface Protocols ASCII, RS up to Baud STX/ETX, 34(R), 34(R) with RK
3 PLC-CPU - with Profibus-DP master VIPA -2BM02 VIPA -2BM02 VIPA -2BM02 CPU DPM CPU DPM CPU DPM Integrated fieldbus connection as master for Profibus-DP Load memory OB1/10/20/35/40//82/85/86/100/121/122 MPI: RS5 Profibus-DP Data Byte I/O max. Connectable slaves 1024/1024Byte 9,6kBaud up to 12MBaud max.124 (without repeater max.31) 18 19
4 PLC-CPU - with Profibus-DP slave VIPA -2BP02 VIPA -2BP02 VIPA -2BP02 CPU DP CPU DP CPU DP Integrated fieldbus connection as slave for Profibus-DP Load memory (kb) OB1/10/20/35/40//82/85/86/100/121/122 MPI: RS5 Profibus-DP Data Addresses Communication frame I/O /64Byte 9.6kBaud up to 12MBaud 20 21
5 PLC-CPU - with CANopen master/slave VIPA -2CM02 VIPA -2CM02 VIPA -2CM02 CPU CAN CPU CAN CPU CAN Integrated fieldbus connection as master or slave for CANopen Load memory OB1/10/20/35/40//82/85/86/100/121/122 MPI: RS5 CANopen Data Connectable slaves Process data Operating modes Configuration tool max.126 (64 per segment) 10kBaud up to 1MBaud each 40PDOs, time or event controlled PDO-Linking, -Mapping, Sync-Mode, Emergency Message, Node Guarding, Heartbeat WinCoCT 22 23
6 PLC-CPU - with Ethernet-CP 243 VIPA -2BT02 VIPA -2BT10 VIPA -2BT02 VIPA -2BT10 VIPA -2BT02 VIPA -2BT10 CPU NET CPU NET CPU NET CPU NET CPU NET CPU NET Integrated Ethernet-CP active connections 8 PU/OP channels Event controlled communication for optimized net load Load memory (kb) OB1/10/20/35/40//82/85/86/100/121/122 MPI: RS5 Ethernet Data Ethernet-CP 2431xRJ45; 10/100MBit/s Protocols Multiprotocol TCP/IP; RFC 1006 Connections Order types TCP/IP Send, Receive, Fetch (a/p), Write (a/p) UDP Multicast, Broadcast PU channels 8 Configuration tool WinNCS Connection configuration, diagnosis and module search function, FW update via network, password protection, IP address filter 24 25
7 for STEP5 PLC-CPU for STEP5 to S5-115U VIPA MC5 or STEP5 Standard AS511-interface for PU and OP Memory Battery buffer Clock S- Typ. processing time Addressable I/O digital Addressable I/O analog kB 32kB 52kB 104kB yes no no yes yes / µs Application processing cyclic time alarm VIPA 241-1BA01 CPU 241 VIPA 242-1BA01 CPU 242 VIPA 243-1BA01 CPU 243 VIPA 244-1BA01 CPU 244 VIPA HB99E Manual VIPA CPUs 24x System 200V 26 27
8 for STEP5 PLC-CPU with Profibus-DP slave for STEP5 to S5-115U VIPA MC5 or STEP5 Standard AS511-interface for PU and OP Integrated fieldbus connection as intelligent Profibus-DP slave Memory 8kB 32kB 52kB 104kB Battery buffer yes Clock no no yes yes / 20 S Typ. processing time 1.8µs Addressable I/O digital 1024 Addressable I/O analog 256 Application processing cyclic time alarm VIPA 241-2BP01 VIPA 242-2BP01 VIPA 243-2BP01 VIPA 244-2BP01 CPU 241DP CPU 242DP CPU 243DP CPU 244DP Profibus-DP Data Addresses Communication frame I/O /64Byte 9.6kBaud up to 12MBaud VIPA HB99E Manual VIPA CPUs 24x System 200V 28 29
9 for STEP5 PLC-CPU with Ethernet-CP 243 for STEP5 to S5-115U VIPA MC5 or STEP5 Standard AS511-interface for PU and OP MMC up to 64MB as Integrated Ethernet-CP active connections, 8 PU/OP channels Event controlled communication for optimized net load Memory 8kB 32kB 52kB 104kB Battery buffer yes Clock no no yes yes / 20 S Typ. processing time 1.8µs Addressable I/O digital 1024 Addressable I/O analog 256 Application processing cyclic time alarm VIPA 241-2BT02 VIPA 242-2BT02 VIPA 243-2BT02 VIPA 244-2BT02 VIPA HB99E CPU 241NET CPU 242NET CPU 243NET CPU 244NET Manual VIPA CPUs 24x System 200V Ethernet Data Ethernet-CP 2431xRJ45; 10/100MBit/s Protocols Multiprotocol TCP/IP; RFC 1006 Connections Order types TCP/IP Send, Receive, Fetch (a/p), Write (a/p) UDP Multicast, Broadcast Configuration tool WinNCS Connection configuration, diagnosis and module search function, FW update via network, password protection, IP address filter 30 31
10 Compact-PC PC-CPU 288 DIN rail PC Fast 6DX processor Active bus access, Profibus-DP master connectable Stand-alone or up to 32 I/O and function modules connectable Standard interfaces for Monitor/LCD, keyboard, mouse and printer Ethernet-TCP/IP via Twisted-Pair RJ45 Programming in C CPU DRAM/Flash ROM internal Compact Flash/HDD external COM1 Flat panel (DVI-D) Video monitor (DVI-A) Keyboard/Mouse Ethernet interface RJ BL10 STPC Industrial 6DX 66MHz 32MB/8MB max. MB/1GB RS232/RS422/RS5 TFT max. 1024x768 Max. 12x1024 at 75MHz PS2 10/100 Base Tx VIPA 288-2BL10 PC-CPU 288 VIPA HB97E Manual VIPA System 200V 32 33
Structure and Function
Communication processors Communication processors Structure and Function Communication processors for the connection of different target and source systems, such as via Ethernet to higher-level MES and
More informationData sheet CPU 315SN/NET (315-4NE12)
Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP
More informationData sheet CPU 315SN/NET (315-4NE12)
Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP
More informationData sheet CPU 315SN/PN ECO (315-4PN33)
Data sheet CPU 315SN/PN ECO (315-4PN33) Technical data Order no. 315-4PN33 CPU 315SN/PN ECO General information Note - Features SPEED-Bus - SPEED7 technology work memory PtP PROFINET controller integrated
More informationData sheet CPU 315SB/DPM (315-2AG12)
Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. ) PROFIBUS-DP
More informationData sheet VIPA CPU 214NET PG (214-2BT13)
Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active
More informationData sheet VIPA CPU M13C (M13-CCF0000)
Data sheet VIPA CPU M13C (M13-CCF0000) Technical data Order no. M13-CCF0000 Type VIPA CPU M13C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power
More informationMain Catalog 2012/2013 for specialists in automation and control technology
Main Catalog 2012/2013 for specialists in automation and control technology www.vipa.com Welcome to VIPA This is VIPA Specialists in automation and control systems. Developer in some to the most advanced
More informationData sheet CPU 315SB/DPM (315-2AG12)
Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP
More informationData sheet VIPA CPU 214PG (214-2BE03)
Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:
More informationData sheet CPU 015PN (015-CEFPR00)
Data sheet CPU 015PN (015-CEFPR00) Technical data Order no. 015-CEFPR00 CPU 015PN Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power supply (permitted
More informationData sheet CPU 015PN (015-CEFPR01)
Data sheet CPU 015PN (015-CEFPR01) Technical data Order no. Module ID - General information Note - Features Technical data power supply 015-CEFPR01 CPU 015PN Powered by SPEED7 Work memory [KB]: 256...512
More informationData sheet SLIO CPU 015PN (015-CEFPR01)
Data sheet SLIO CPU 015PN (015-CEFPR01) Technical data Order no. 015-CEFPR01 Type SLIO CPU 015PN Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max.
More informationDistributed Control I/O System ADAM-8000 Series
Distributed Control I/O System Series 16 Series Distributed Control I/O 16-2 Series Total Fieldbus Solution 16-4 CPU s ADAM8214-1BA01 PLC CPU214 16-6 ADAM8214-2BM01 PLC CPU214 with Profibus-DP Master 16-6
More informationData sheet VIPA CPU 115DP (115-6BL22)
Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO
More informationVIPA System 300S - The High-Speed control system
Software HMI System 500S System 400V System 300V System 300S System 200V System 100V High-speed control system programmable with STEP 7 from Siemens Features VIPA System 300S: Programmable with Step 7
More information200V. The modular control system.
200V The modular control system www.vipa.com 200V Flexible in every direction Step7 code programmable with WinPLC7 from VIPA or the SIMATIC Manager Performance and application Programming Memory 200V designed
More informationData sheet CPU 013C (013-CCF0R00)
Data sheet CPU 013C (013-CCF0R00) Technical data Order no. 013-CCF0R00 Type CPU 013C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power supply
More informationCommander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.
0-CC 0-CC Order number 0-CC 0-CC Figure Type CC 0, Commander Compact CC 0DP, Commander Compact, PROFIBUS-DP slave General information Note - - Features x 0 characters, x 0 characters, Integrated PLC-CPU,
More informationData sheet CC 03, Commander Compact (603-1CC21)
Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU 317-2 PN/DP, CENTRAL PROCESSING UNIT WITH 1 MB WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU 315-2 PN/DP, CENTRAL PROCESSING UNIT WITH 384 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU315F-2 PN/DP, CENTRAL PROCESSING UNIT WITH 512 KBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET, WITH 2 PORT SWITCH, MICRO MEMORY CARD NECESSARY
More informationSIMATIC S PRICE LIST
SIMATIC S7-1500 PRICE LIST CPU Part number Description Origin 6ES7511-1AK00-0AB0 CPU 1511-1 PN, WORKING MEMORY 150 KB FOR PROGRAM AND 1 MB FOR DATA, 60 NS BIT-PERFORMANCE, list DE 215 865.00 951.50 6ES7513-1AL00-0AB0
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300 CPU319F-3 PN/DP, CENTRAL PROCESSING UNIT WITH 2.5 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, 3. INTERFACE ETHERNET PROFINET, WITH 2 PORT
More informationParameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:
CPU 315-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the
More informationCPU 319F-3 PN/DP. Page 1682 Mar 2008 Siemens ITS
CPU 319F-3 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 100 error and interrupt events are stored in a buffer
More informationThe possibility of combining interface modules allows various bus and network systems to be integrated into the B&R SYSTEM 2005.
5.2 CP260 5.2.1 General Information The CPU is inserted in the main rack directly next to the power supply module. It requires two slots. Only the status LEDs can be seen with the module door closed. The
More informationGeneral information. Supply voltage. Input current
Data sheet SIMATIC S7-300, CPU 315F-2DP FAILSAFE CPU WITH MPI INTERFACE INTEGRATED 24V DC POWER SUPPLY, 384 KB WORKING MEMORY, 40MM WIDE, 2. INTERFACE DP- MASTER/SLAVE MICRO MEMORY CARD REQUIRED General
More information6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB
Automation Technology > Automation Systems > Industrial Automation Systems SIMATIC > Distributed I/Os SIMATIC ET200 > ET 200 systems for the cabinet > ET 200S > Interface modules > Interface modules with
More information2017/18. System Summary. for specialists in automation and control technology.
2017/18 System Summary for specialists in automation and control technology www.vipa.com Welcome to VIPA Controls 250 EMPLOYEES IN OVER 60 COUNTRIES over 30 YEARS OF EXPERIENCE 3200 DIFFERENT ARTICLES
More informationSIMATIC S7-400, CPU KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.
Product data sheet SIMATIC S7-400, CPU 414-3 768 KB WORKING MEMORY (384 KB CODE, 384 KB DATA) 1. INTERFACE MPI/DP 12 MBIT/S 2.IF PROFIBUS DP, 3.IF FOR IFM CiR - Configuration in RUN CiR synchronization
More informationSystem description SLIO
10 Appendix Software Solutions System description System description Structure and Concept stands for Slice I/O. The system is very compact and can be adapted piecemeal exactly to the requirements of the
More informationProduct type designation. General information. Supply voltage. Input current. Power loss
Data sheet SIMATIC S7-300, CPU 315-2DP CPU WITH MPI INTERFACE INTEGRATED 24 V DC POWER SUPPLY 256 KBYTE WORKING MEMORY 2. INTERFACE DP-MASTER/SLAVE MICRO MEMORY CARD NECESSARY Product type designation
More informationOperating and Monitoring Systems
Operating and Monitoring Systems System description System description Structure and Concept The VIPA Touch Panel with 5.7" to 12.1" display, Windows CE 5.0/6.0 and visualization system can be used universally.
More informationCPU 317F-2 DP. Page 1603 Mar 2008 Siemens ITS
CPU 317F-2 DP Function Password protection; a password concept protects the user program from unauthorized access. Diagnostics buffer; the last 100 errors and interrupt events are saved in a buffer for
More informationSupply voltage. Input current. Power loss. Memory. Battery. CPU processing times
Data sheet SIMATIC S7-400H, CPU 417H CENTRAL UNIT FOR S7-400H 4 INTERFACES: 1 MPI/DP, 1 DP A. 2 FOR SYNC MODULES 4MB MEMORY (2MB CODE/2MB DATA) Supply voltage Rated value (DC) 24 V DC Input current from
More informationDeutschmann Automation,
FLEXIBLE GATEWAYS FOR INDUSTRIAL COMMUNICATION Easy installation Norm compliant Ready-to-use Configurable Programmable Designed & manufactured in Germany ETHERNET TCP/IP Protocol Converter Embedded Solutions
More informationProduct type designation. General information. Supply voltage. Input current. Power losses
Data sheet SIMATIC S7-300, CPU317-2 DP, CENTRAL PROCESSING UNIT WITH 1 MBYTE WORKING MEMORY, 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE DP-MASTER/SLAVE, MICRO MEMORY CARD NECESSARY Product type designation
More informationSTATUS COM FAIL CONFIGURATION ERROR READY RUN BUS HMS FIELDBUS SYSTEMS AB PILEFELTSGATAN SE HALMSTAD, SWEDEN
User Manual Profibus Master Module Doc. No. H252-PDPM PDPM-1.31 PROCESS FIELD BUS BUS ON ERROR READY RUN CONFIGURATION STATUS COM FAIL HMS FIELDBUS SYSTEMS AB PILEFELTSGATAN 93-95 SE-302 50 HALMSTAD, SWEDEN
More informationGeneral information. Configuration control. Display. Control elements. Supply voltage
Data sheet SIMATIC S7-1500, CPU 1516-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE:
More informationUNIGATE CL THE RESULT MUST AGREE BUS-TECHNOLOGY MADE BY DEUTSCHMANN! A solution for all devices with serial interface
THE RESULT MUST AGREE BUS-TECHNOLOGY MADE BY DEUTSCHMANN! UNIGATE CL A solution for all devices with serial interface The intelligent protocol converter for: The intelligent Protocol converter UNIGATE
More informationTraining document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D3
Training document for the company-wide automation solution Totally Integrated Automation (T I A) MODULE D3 PROFIBUS DP with Master CPU 315-2DP / Slave ET 200L T I A Training document Page 1 of 18 Module
More informationGeneral information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss
Data sheet SIMATIC S7-1500, CPU 1516-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE:
More informationFieldbus slave modules w/o I/Os
tem SLIO Fieldbus slave modules w/o I/Os tem 500S tem 300S tem 100V Order number Figure Type IM 053CAN, CANopen slave IM 053DN, DeviceNet slave IM 053DP, PROFIBUS-DP slave IM 053EC, EtherCAT slave General
More informationGeneral information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationS7-400 CPU ES XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI;
S7-400 CPU 412-1 6ES7 412-1XJ05-0AB0 V5.2 Work memory 144KB code and 144KB of data; 0.075 ms/1000 instructions; 4KB DI/O; 32 connections 1*DP/MPI; send and receive capability for direct data exchange;
More informationProduct type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory
Data sheet SIMATIC S7-400H, CPU 414-5H, CENTRAL UNIT FOR S7-400H AND S7-400F/FH, 5 INTERFACES: 1X MPI/DP, 1X DP, 1X PN AND 2 FOR SYNC MODULES 4 MB MEMORY (2 MB DATA/2 MB CODE) Product type designation
More informationTrajexia motion controller
SP IM G AC SERVO DRIVER ADR 0 0 X10 X1 COM 1 3 3 2 9 8 6 7 5 1 4 2 SW1 SW2 CN2 CN1 A/B GRT1-ML2 TJ Trajexia motion controller Motion controllers Stand-alone advanced motion controller over MECHATROLINK-II
More informationCP ADVANCED. Function
CP 343-1 ADVANCED Function The CP 343-1 Advanced independently handles data traffic over Industrial Ethernet. The module has its own processor and can be put into service directly using the unique preset
More informationWAGO-I/O-IPC. Maximum Processing Power in Minimal Space
WAGO-I/O-IPC Maximum Processing Power in Minimal Space PC Performance in the Field Maximum flexibility and scalable system design: IPC connection for the WAGO-I/O-SYSTEM Consistent decentralization of
More informationProduct type designation. General information. CiR - Configuration in RUN. Input current. Power loss. Memory
Data sheet SIMATIC S7-400, CPU 412-2 CENTRAL PROCESSING UNIT WITH: 512 KB WORKING MEMORY, (256 KB CODE, 256 KB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP Product type designation General
More informationFLEXIBLE GATEWAYS FOR INDUSTRIAL COMMUNICATION
FLEXIBLE GATEWAYS FOR INDUSTRIAL COMMUNICATION Easy installation Norm compliant Ready-to-use Configurable Programmable Designed & manufactured in Germany ETHERNET TCP/IP Protocol Converter Embedded Solutions
More informationCPU 412H. Function. Parameterizable properties
CPU 412H Function Block protection: In addition to the keylock switch, a password concept protects the user program from unauthorized access. Integrated HMI services: In the case of HMI devices, the user
More informationWAGO I/O - IPC PLC Control with PC features
WAGO I/O - IPC PLC Control with PC features PLC Control... PC Features... The WAGO-I/O-IPC Series 758 Today's engineers face many decisions regarding their control strategy of today and for tomorrow. One
More informationQ.brixx station 101. Base Unit with Test Controller. Most important features:
Most important features: Q.brixx base unit consists of side handles, Test Controller Q.brixx station and power supply unit, ready for 14 measurement modules in the same housing and up to 32 plug-in modules
More informationData sheet CPU 115 (115-6BL02)
Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,
More informationIP67 IP20. Controllers Open Flexible Compact SPEEDWAY. Programmable. Fieldbus Couplers. Programmable. Fieldbus Controllers
WAGO Controllers Controllers Open Flexible Compact WAGO s IEC 61131-3 programmable controllers perform a variety of automation tasks, while providing all the benefits of standard PLC technology (e.g.,
More informationGeneral information. Display. Control elements. Supply voltage
Data sheet SIMATIC S7-1500F, CPU 1516F-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1,5 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET,
More informationProgramming package STEP 7 V5.2 SP1 or higher with HSP 0126
Product data sheet SIMATIC S7-300, CPU 315F CENTRAL UNIT FOR S7-300F, 192 KB WORKING MEM., 40MM WIDE, 384 BYTES PAE/384 BYTES PAA, 2 INTERFACES: 1 MPI UND 1 DP INTEGRATED 24V DC POWER SUPPLY, MICRO MEMORY
More informationUNIGATE UNIGATE CM CM GATEWAY SERIES. CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL ETHERNET. Easy installation. Norm compliant.
UNIGATE GATEWAY SERIES UNIGATE CM CM Easy installation Norm compliant Ready-to-use Configurable Designed & manufactured in Germany THE INTELLIGENT SOLUTION FOR: ETHERNET TCP/IP CAN/CANopen TO ALL FIELDBUSES
More informationProduct type designation
Data sheet SIMATIC DP, CPU 1512SP-1 PN FOR ET 200SP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 200 KB FOR PROGRAM AND 1 MB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 3 PORT SWITCH, 48 NS BIT-PERFORMANCE,
More informationManual VIPA System 500S SPEED7 - CPU
Manual VIPA System 500S SPEED7 - CPU Order No.: VIPA HB145E_CPU Rev. 06/47 Lerrzeichen Manual VIPA System 500S SPEED7 The information contained in this manual is supplied without warranties. Information
More informationEmbedded PC. Highlights. . Compact design. Scalable performance range. . Direct I/O interface Modular extension options DIN rail mounting
180. Highlights. Scalable performance range. Compact design.. Direct I/O interface... Modular extension options DIN rail mounting Modular DIN rail IPCs and Industrial Motherboards u www.beckhoff.com/embedded-pc
More informationIndustrial Control SE-607
Industrial Control SE-607 Controller and visualization combined as an automation solution with infrared touch operation Trend-setting industrial controls for heat treatment plants The controller is equipped
More informationGeneral information. Configuration control. Display. Control elements. Supply voltage
Data sheet SIMATIC S7-1500, CPU 1513-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 300 KB FOR PROGRAM AND 1.5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 40 NS BIT-PERFORMANCE, SIMATIC
More information300S. The high speed control system powered by SPEED7.
300S The high speed control system powered by SPEED7 www.vipa.com 300S at a glance SPEED7 Studio Teleservice OPC VIPA Touch Panels 300S, powered by SPEED7, makes this system one of the fastest and most
More information. PC cards for all common fieldbus. systems Industrial Ethernet switches. . EtherCAT junctions and media converters in IP 20 and IP 67 ratings
610. Highlights. PC cards for all common fieldbus. systems. Industrial Ethernet switches. EtherCAT junctions and media converters in IP 20 and IP 67 ratings Infrastructure Components PC Fieldbus Cards,
More information100 ms. 30 µs; Time per I/O byte. 24 V DC No; Power supply via system power supply. Not relevant for 400 series (300 series set)
6ES7412-2XJ05-0AB0 SIMATIC S7-400, CPU 412-2 CENTRAL PROCESSING UNIT WITH: 512 KB WORKING MEMORY, (256 KB CODE, 256 KB DATA), 1. INTERFACE MPI/DP 12 MBIT/S, 2. INTERFACE PROFIBUS DP Product type designation
More informationGeneral information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss
Data sheet SIMATIC S7-1500, CPU 1515-2 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 500 KB FOR PROGRAM AND 3 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 30 NS
More informationGeneral information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss
Data sheet SIMATIC S7-1500, CPU 1511-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 150 KB FOR PROGRAM AND 1 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC
More informationGeneral information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory
Data sheet SIMATIC S7-400, CPU 412-2 PN CENTRAL PROCESSING UNIT WITH: 1 MB WORKING MEMORY, (0,5 MB CODE; 0,5 MB DATA) INTERFACES: 1. IF MPI/DP 12 MBIT/S (X1), 2. IF ETHERNET/PROFINET (X5), General information
More informationUNIGATE CL CL. Protocol Converter. A solution for all devices with a serial interface. Easy installation. Norm compliant. Ready-to-use.
UNIGATE ProtoCol Converter UNIGATE CL CL Easy installation Norm compliant Ready-to-use Configurable Programmable Designed & manufactured in Germany The intelligent Protocol Converter for ETHERNET TCP/IP
More informationUNIGATE UNIGATE ALL-IN-ONE BUS NODE 32 DIL. Norm compliant. Certified. Programmable. Designed & manufactured in Germany. READY-TO-INSTALL for MPI
UNIGATE ALL-IN-ONE BUS NODE UNIGATE IC IC 32 DIL Norm compliant Certified Programmable Designed & manufactured in Germany READY-TO-INSTALL for ETHERNET TCP/IP MPI Integrate with little development effort
More informationProduct type designation. General information. Supply voltage
Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1
More informationGeneral information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.
Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING
More informationProduct type designation. General information. CiR - Configuration in RUN. Supply voltage. Input current. Power loss. Memory
Data sheet SIMATIC S7-400, CPU 417-4 CENTRAL PROCESSING UNIT WITH: 30 MB WORKING MEMORY, (15 MB CODE; 15 MB DATA) 1. INTERFACE MPI 12 MBIT/S, 2. INTERFACE PROFIBUS DP, 3./4. IF IFM MODULES PLUGGABLE Product
More informationThe intelligent solution
GATEWAY SERIES UNIGATE CM Easy installation Norm compliant Ready-to-use Configurable Designed & manufactured in Germany THE INTELLIGENT SOLUTION FOR: ETHERNET TCP/IP CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL
More informationGeneral information. Display. Control elements. Supply voltage
Data sheet SIMATIC S7-1500F, CPU 1511F-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 225 KB FOR PROGRAM AND 1 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 60 NS BIT-PERFORMANCE, SIMATIC
More informationSIPLUS CPU 313C-2DP. Function
SIPLUS CPU 313C-2DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in
More informationEmbedded PC. Highlights. . Compact design. Scalable performance range. . Direct I/O interface Modular extension options DIN rail mounting
184. Highlights. Scalable performance range. Compact design.. Direct I/O interface... Modular extension options DIN rail mounting Modular DIN rail IPCs and Industrial Motherboards u www.beckhoff.com/embedded-pc
More informationProvisional documentation, Profibus-DP and Profi-S-IO Contents
Provisional documentation, Profibus-DP and Profi-S-IO Contents 1 INTRODUCTION 3 2 CONFIGURATION 3 2.1 INTERFACES 3 2.2 POSSIBLE COMBINATIONS 3 2.2.1 Overview 3 2.2.2 Configuration details 4 2.2.3 Recommended
More informationProduct type designation. General information. Supply voltage
Data sheet SIMATIC S7-300, CPU 314C-2PN/DP COMPACT CPU WITH 192 KBYTE WORKING MEMORY, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), 1. INTERFACE MPI/DP 12MBIT/S, 2. INTERFACE ETHERNET PROFINET,
More informationCONTROLS AMERICA 2017/18. System Summary. for specialists in automation and control technology.
CONTROLS AMERICA 2017/18 System Summary for specialists in automation and control technology www.vipausa.com Welcome to VIPA Controls 250 EMPLOYEES 40,000,000 EUR TURNOVER over 30 YEARS OF EXPERIENCE 800
More informationTIM 3V- IE ADVANCED. Function
TIM 3V- IE ADVANCED Function The TIM 3V-IE Advanced enables one or more SIMATIC S7-300 or control center PCs (e.g. SINAUT ST7cc or ST7sc) to exchange data with other SINAUT ST7 or ST1 stations via any
More informationPM572, PM573, PM582, PM583, PM585, PM590, PM591, PM592
Ordering Data DATA SHEET PM572, PM573, PM582, PM583, PM585, PM590, PM591, PM592 Processor Module 1 Ordering Data Processor Modules for AC500 (Standard) V2 Products Part No. Description Product Life Cycle
More informationCAN 300 PRO, Communication Module
90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB
More informationSIMATIC PC-based controller
Siemens AG 2011 /2 /2 SIMATIC WinAC RTX /9 SIMATIC WinAC RTX F /16 SIMATIC WinAC ODK Brochures For brochures serving as selection guides for SIMATIC products refer to: http://www.siemens.com/simatic/ printmaterial
More informationDevice/PLC Connection Manuals
Device/PLC Connection Manuals About the Device/PLC Connection Manuals Prior to reading these manuals and setting up your device, be sure to read the "Important: Prior to reading the Device/PLC Connection
More informationGeneral information. Display. Supply voltage. Input current
Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC
More informationGeneral information. Display. Control elements. Supply voltage
Data sheet SIMATIC S7-1500F, CPU 1513F-1 PN, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 450 KB FOR PROGRAM AND 1.5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 40 NS BIT-PERFORMANCE, SIMATIC
More informationC ed P d ed b Em 184
184 Modular DIN rail IPCs and Industrial Motherboards 185 186 190 s 254 Industrial Motherboards Embedded Automation 187 190 192 196 198 202 202 203 203 204 204 205 205 205 s Product overview System description
More informationGeneral information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory
Datasheet SIMATIC DP, CPU 1510SP-1 PN FOR ET 200SP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 100 KB FOR PROGRAM AND 750 KB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 3 PORT SWITCH, 72 NS BIT-PERFORMANCE,
More information64 kbyte ; 64 KB / 21K instructions RAM (integrated) Yes ; 4 KB: bit memory, counter, times and data
Product data sheet SIMATIC S7-300, CPU 315-2 DP CPU WITH INTEGRATED 24 V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY 2ND INTERFACE DP- MASTER/SLAVE Supply voltage Rated voltage/dc permissible range, lower
More informationTrajexia Motion Controller
CN2 A/B CN1 SW1 GRT1-ML2 SW2 TJ1- Trajexia Motion Controller Stand-Alone Advanced Motion Controller Using MECHATROLINK-II Motion Bus 16 axes advanced motion coordination over a robust and fast motion link:
More informationShort Description. Version
S7-400 S7-400 CP 443-1 6GK7 443-1EX11-0XE0 V2.6 S7 CP for Industrial Ethernet ISO and TCP/IP with SEND/RECEIVE and FETCH/WRITE interface, long data, UDP, TCP, ISO, S7 communication, routing, module replacement
More informationIntegrate the Fieldbus into your device without much development effort involved! All-in-one single bus node for:
THE RESULT MUST AGREE BUS-TECHNOLOGY MADE BY DEUTSCHMANN! UNIGATE IC Integrate the Fieldbus into your device without much development effort involved! All-in-one single bus node for: RK512 The intelligent
More informationProduct type designation. General information. Supply voltage. Input current
Data sheet SIMATIC S7-300, CPU 312C COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD
More informationAPPLICATION NOTES. Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG
APPLICATION NOTES Advanced Graphical Interface - AGI Internal PLC (CODESYS V3) SHENDONG CODESYS V3 logic running on AGI 300/400 series product Support of Modbus/TCP and RTU communication Use of remote
More informationIntelligent Communication Server. AC&T Products Guide. ETOS-300X ETOS-150X ETOS-100X ETOS-50X Profibus / CC-link. AC&T System Co., Ltd.
Intelligent Communication Server AC&T Products Guide ETOS-300X ETOS-150X ETOS-100X ETOS-50X Profibus / CC-link AC&T System Co., Ltd. ETOS-X Series Products Overview ETOS-X series is an industrial communication
More information