Fieldbus slave modules w/o I/Os

Size: px
Start display at page:

Download "Fieldbus slave modules w/o I/Os"

Transcription

1 tem SLIO Fieldbus slave modules w/o I/Os tem 500S tem 300S tem 100V Order number Figure Type IM 053CAN, CANopen slave IM 053DN, DeviceNet slave IM 053DP, PROFIBUS-DP slave IM 053EC, EtherCAT slave General information Note - Coming soon - Coming soon Features CANopen slave, 16 Rx und 16 Tx PDOs, DeviceNet slave, Group 2 only Device, PROFIBUS-DP slave (DP-V0, DP-V1), EtherCAT slave 2 SDOs, Poll only Device For max. 64 Periphery modules, PDO-Linking, 244 Byte input and PDO-Mapping: fix 244 Byte output data Technical data power supply Power supply (rated value) Power supply (permitted range) DC V DC V DC V DC V Reverse polarity protection Current consumption (no-load operation) Current consumption (rated value) 1.9 A 1.2 A 1.9 A 1.2 A Inrush current I²t Max. current drain at backplane bus 3 A 3 A 3 A 3 A Max. current drain load supply Power loss Status information, alarms, diagnostics Status display yes yes yes yes Interrupts yes, parameterizable - yes, parameterizable yes, parameterizable Process alarm no - yes, parameterizable yes, parameterizable Diagnostic interrupt yes, parameterizable - yes, parameterizable yes, parameterizable Diagnostic functions yes, parameterizable - yes, parameterizable yes, parameterizable Diagnostics information read-out possible - possible - Supply voltage display green LED green LED green LED green LED Group error display red SF LED red SF LED red SF LED red SF LED Channel error display none none none none Hardware config Racks, max Modules per rack, max Number of digital modules, max Number of analog modules, max Communication Field bus CANopen DeviceNet PROFIBUS-DP to EN EtherCat Type of interface CAN - RS485 isolated - 64

2 Fieldbus slave modules w/o I/Os Interface modules tem SLIO Order number Connector Sub-D, 9-pin, male 5-pin Open Style Connector Sub-D, 9-pin, female RJ45 Topology Linear bus with bus termination at both ends - Linear bus with bus termination at both ends Electrically isolated - - Number of participants, max Node addresses Transmission speed, min. 10 kbit/s kbit/s - Transmission speed, max. 1 Mbit/s 500 kbit/s 12 Mbit/s 100 Mbit/s Address range inputs, max. 128 Byte 256 Byte 244 Byte 1 KB Address range outputs, max. 128 Byte 256 Byte 244 Byte 1 KB Number of TxPDOs, max Number of RxPDOs, max Mechanical data Dimensions (WxHxD) - Weight 155 g g - Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C 0 C to 60 C 0 C to 60 C Storage temperature -25 C to 70 C -25 C to 70 C -25 C to 70 C -25 C to 70 C Certifications UL508 certification in preparation in preparation in preparation in preparation tem 500S tem 300S tem 100V 65

3 tem SLIO Connections, Interfaces tem 500S tem 300S tem 100V CAN DP slave V- CL DR CH V+ GND CAN low Drain CAN high 66

4 Fieldbus slave modules w/o I/Os Interface modules Fieldbus slave modules w/o I/Os tem SLIO Order number Figure Type IM 053MT, Modbus/TCP slave IM 053PN, PROFINET-IO slave General information Note Coming soon Coming soon Features Modbus/TCP slave, PROFINET-IO slave I/O configuration via field bus, Adjustable I/O cycle (0,5...4 ms) Technical data power supply Power supply (rated value) Power supply (permitted range) DC V DC V Reverse polarity protection - - Current consumption (no-load operation) - - Current consumption (rated value) 1.2 A - Inrush current - - I²t - - Max. current drain at backplane bus 3 A 3 A Max. current drain load supply - - Power loss - - Status information, alarms, diagnostics Status display yes yes Interrupts - - Process alarm - - Diagnostic interrupt - - Diagnostic functions - - Diagnostics information read-out - - Supply voltage display green LED green LED Group error display red SF LED red SF LED Channel error display none none Hardware config Racks, max. - - Modules per rack, max. - - Number of digital modules, max. - - Number of analog modules, max. - - Communication Field bus Modbus / TCP/IP PROFINET-IO Type of interface - - Connector - - Topology - - Electrically isolated tem 500S tem 300S tem 100V

5 tem SLIO tem 500S tem 300S tem 100V Order number Number of participants, max. - - Node addresses - - Transmission speed, min. 10 Mbit/s 10 Mbit/s Transmission speed, max. 100 Mbit/s 100 Mbit/s Address range inputs, max. 256 Byte 1 KB Address range outputs, max. 256 Byte 1 KB Number of TxPDOs, max. - - Number of RxPDOs, max. - - Mechanical data Dimensions (WxHxD) Weight - - Environmental conditions Operating temperature 0 C to 60 C 0 C to 60 C Storage temperature -25 C to 70 C -25 C to 70 C Certifications UL508 certification in preparation in preparation 68

6 Fieldbus slave modules w/o I/Os Interface modules Connections, Interfaces tem SLIO Net tem 500S tem 300S tem 100V 69

Structure and Function

Structure and Function Communication processors Communication processors Structure and Function Communication processors for the connection of different target and source systems, such as via Ethernet to higher-level MES and

More information

Data sheet CPU 015PN (015-CEFPR00)

Data sheet CPU 015PN (015-CEFPR00) Data sheet CPU 015PN (015-CEFPR00) Technical data Order no. 015-CEFPR00 CPU 015PN Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power supply (permitted

More information

Data sheet CPU 015PN (015-CEFPR01)

Data sheet CPU 015PN (015-CEFPR01) Data sheet CPU 015PN (015-CEFPR01) Technical data Order no. Module ID - General information Note - Features Technical data power supply 015-CEFPR01 CPU 015PN Powered by SPEED7 Work memory [KB]: 256...512

More information

Data sheet VIPA CPU M13C (M13-CCF0000)

Data sheet VIPA CPU M13C (M13-CCF0000) Data sheet VIPA CPU M13C (M13-CCF0000) Technical data Order no. M13-CCF0000 Type VIPA CPU M13C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power

More information

Data sheet SLIO CPU 015PN (015-CEFPR01)

Data sheet SLIO CPU 015PN (015-CEFPR01) Data sheet SLIO CPU 015PN (015-CEFPR01) Technical data Order no. 015-CEFPR01 Type SLIO CPU 015PN Module ID - General information Note - Features SPEED7 technology 256 kb work memory Memory extension (max.

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Data sheet VIPA CPU 115DP (115-6BL22)

Data sheet VIPA CPU 115DP (115-6BL22) Data sheet VIPA CPU 115DP (115-6BL22) Technical data Order no. Type 115-6BL22 VIPA CPU 115DP General information Note - Features Work memory [KB]: 16 Load memory [KB]: 24 Onboard 16x DI / 12x DO / 4x DIO

More information

Data sheet VIPA CPU 214PG (214-2BE03)

Data sheet VIPA CPU 214PG (214-2BE03) Data sheet VIPA CPU 214PG (214-2BE03) Technical data Order. General information Note - 214-2BE03 VIPA CPU 214PG Features Work memory [KB]: 96 Interface [RJ45]: Ethernet PG/OP communication Interface [RS485]:

More information

Data sheet VIPA CPU 214NET PG (214-2BT13)

Data sheet VIPA CPU 214NET PG (214-2BT13) Data sheet VIPA CPU 214NET PG (214-2BT13) Technical data Order. 214-2BT13 VIPA CPU 214NET PG General information Note - Features Work memory [KB]: 96 Integrated Ethernet CP 243 Interface [RJ45]: active

More information

Data sheet CPU 315SN/PN ECO (315-4PN33)

Data sheet CPU 315SN/PN ECO (315-4PN33) Data sheet CPU 315SN/PN ECO (315-4PN33) Technical data Order no. 315-4PN33 CPU 315SN/PN ECO General information Note - Features SPEED-Bus - SPEED7 technology work memory PtP PROFINET controller integrated

More information

Data sheet CPU 315SB/DPM (315-2AG12)

Data sheet CPU 315SB/DPM (315-2AG12) Data sheet CPU 315SB/DPM (315-2AG12) Technical data Order no. 315-2AG12 CPU 315SB/DPM General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. ) PROFIBUS-DP

More information

Data sheet CPU 115 (115-6BL02)

Data sheet CPU 115 (115-6BL02) Data sheet CPU 115 (115-6BL02) Technical data Order no. 115-6BL02 Type CPU 115 General information Note - Features 16 (20) inputs 16 (12) outputs from which are 2 PWM 50 khz outputs 16 kb work memory,

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Data sheet CPU 315SN/NET (315-4NE12)

Data sheet CPU 315SN/NET (315-4NE12) Data sheet CPU 315SN/NET (315-4NE12) Technical data Order no. 315-4NE12 CPU 315SN/NET General information Note - Features SPEED-Bus - SPEED7 technology 1 MB work memory Memory extension (max. 2 MB) PROFIBUS-DP

More information

Data sheet CPU 013C (013-CCF0R00)

Data sheet CPU 013C (013-CCF0R00) Data sheet CPU 013C (013-CCF0R00) Technical data Order no. 013-CCF0R00 Type CPU 013C Module ID - General information Note - Features Technical data power supply Power supply (rated value) Power supply

More information

System description SLIO

System description SLIO 10 Appendix Software Solutions System description System description Structure and Concept stands for Slice I/O. The system is very compact and can be adapted piecemeal exactly to the requirements of the

More information

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet CC 03, Commander Compact (603-1CC21) Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:

More information

Main Catalog 2012/2013 for specialists in automation and control technology

Main Catalog 2012/2013 for specialists in automation and control technology Main Catalog 2012/2013 for specialists in automation and control technology www.vipa.com Welcome to VIPA This is VIPA Specialists in automation and control systems. Developer in some to the most advanced

More information

PA ROUTERS. The following criteria can be applied when choosing the network transition:

PA ROUTERS. The following criteria can be applied when choosing the network transition: PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied

More information

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21.

Commander compact. Commander compact Lines displays. System SLIO. System 100V. Lines displays Commander compact 603-1CC CC21. 0-CC 0-CC Order number 0-CC 0-CC Figure Type CC 0, Commander Compact CC 0DP, Commander Compact, PROFIBUS-DP slave General information Note - - Features x 0 characters, x 0 characters, Integrated PLC-CPU,

More information

Part no.: CML720i-T R-M12 Light curtain transmitter

Part no.: CML720i-T R-M12 Light curtain transmitter Technical data Basic data Series 720 Operating principle Throughbeam principle Device type Transmitter Contains Accessories for the use of the BT-2R1 Application Object measurement Optical data Operating

More information

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI Characteristics Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI Main Range of product Product or component type Product specific application Complementary Product compatibility

More information

VIPA System SLIO. IM 06x-1xA00 Manual. HB300 IM 06x-1xA00 en Interface module Line extension - IM 06x.

VIPA System SLIO. IM 06x-1xA00 Manual. HB300 IM 06x-1xA00 en Interface module Line extension - IM 06x. IM 06x-1xA00 Manual HB300 IM 06x-1xA00 en 18-10 Interface module Line extension - IM 06x www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: 09132-744-0 Fax: 09132-744-1864

More information

SAI Active Universal Pro

SAI Active Universal Pro Universal Pro - Overview Universal Pro Professional versions of the Remote I/O System featuring IP67 protection The modules in the Universal Pro systems provide additional I/O and functional modules for

More information

PSG55x ATM to Medium Vacuum Gauge

PSG55x ATM to Medium Vacuum Gauge The INFICON Pirani Standard Gauge (PSG55x) employs like his brothers PCG55x and PSG50x the most advanced digital Pirani technology available. The rugged sensor design combined with the compact size and

More information

PAS 300, PROFIBUS Slave Interface Module

PAS 300, PROFIBUS Slave Interface Module Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz

More information

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP

IM IM in the RS485 variants features: 9-pin Sub-D socket for connection to PROFIBUS DP IM 151-1 Design The IM 151-1 interface modules are directly snapped onto the standard mounting rail. IM 151-1 modules feature: DIP switch for setting the PROFIBUS DP station address (1 to 125) Diagnostics

More information

Control block CPX-CM-HPP

Control block CPX-CM-HPP Key features New options for controlling drive technology The control block CPX-CM-HPP makes all of Festo s electric drive technology compatible with all industrial communication interfaces. CPX-CM-HPP

More information

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory

General information. Configuration control. Control elements. Supply voltage. Input current. Power. Power loss. Memory Datasheet SIMATIC DP, CPU 1510SP-1 PN FOR ET 200SP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 100 KB FOR PROGRAM AND 750 KB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 3 PORT SWITCH, 72 NS BIT-PERFORMANCE,

More information

SKY CDG045D Torr / mbar

SKY CDG045D Torr / mbar INFICON SKY CDG045D manometers are your best choice for high accurate total pressure measurement and control. CDG045D gauges are temperature controlled at 45 C for superior signal stability and repeatability.

More information

General information. Supply voltage

General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

UNIGATE UNIGATE CM CM GATEWAY SERIES. CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL ETHERNET. Easy installation. Norm compliant.

UNIGATE UNIGATE CM CM GATEWAY SERIES. CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL ETHERNET. Easy installation. Norm compliant. UNIGATE GATEWAY SERIES UNIGATE CM CM Easy installation Norm compliant Ready-to-use Configurable Designed & manufactured in Germany THE INTELLIGENT SOLUTION FOR: ETHERNET TCP/IP CAN/CANopen TO ALL FIELDBUSES

More information

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI

BMKC Controller for Parabolic Trough, 8 DI 12 DO 4 AI Characteristics Controller for Parabolic Trough, 8 DI 12 DO 4 AI Main Range of product Product or component type Product specific application Complementary Product compatibility [Us] rated supply voltage

More information

In-Cabinet Block I/O. FDP20 PROFIBUS digital I/O. FEN20 Ethernet digital block I/O. FDN20 DeviceNet block I/O. FAS20 AS-interface digital I/O

In-Cabinet Block I/O. FDP20 PROFIBUS digital I/O. FEN20 Ethernet digital block I/O. FDN20 DeviceNet block I/O. FAS20 AS-interface digital I/O In-Cabinet Block I/O In-cabinet (IP20) block I/O is a cost-efficient networking solution that is used in an enclosure and designed to replace terminal blocks with intelligent I/O. TURCK in-cabinet block

More information

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB

6ES7151-8AB01-0AB0. 5/18/2011 Siemens Industry IA/DT/BT Service&S. siemens.com/ww/llisapi.dll?func=csl 1/10 ET200S, IM151-8 PN/DP CPU, 192 KB Automation Technology > Automation Systems > Industrial Automation Systems SIMATIC > Distributed I/Os SIMATIC ET200 > ET 200 systems for the cabinet > ET 200S > Interface modules > Interface modules with

More information

IE/PB LINK PN IO. PROFINET applications

IE/PB LINK PN IO. PROFINET applications IE/PB LINK PN IO PROFINET applications Protection of investment due to simple connection of PROFIBUS DP slaves to PROFINET IO controller Enables the use also in plants with PROFIsafe applications Independence

More information

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact : Distribué par : Contact : hvssystem@hvssystem.com Tél : 0326824929 Fax : 0326851908 Siège social : 2 rue René Laennec 51500 Taissy France www.hvssystem.com AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC

More information

Revision to the Operating Instructions

Revision to the Operating Instructions Drive Technology \ Drive Automation \ System Integration \ Services *21341397_1114* Revision to the Operating Instructions Decentralized Drive and Application Controller MOVIPRO ADC Edition 11/2014 21341397/EN

More information

3 CH Analog Output module / CANopen

3 CH Analog Output module / CANopen 3 CH Analog Output module / CANopen Power Supply 1..4 Vdc, 19..28 Vac Isolation 1,5 kvac (5 way) Accuracy,5% A/D resolution 14 bit Channels 3 Voltage range 1 V Current range..2, 4..2 ma RPDO < 2 ms (-1%

More information

PCG55x ATM to Medium Vacuum Gauge

PCG55x ATM to Medium Vacuum Gauge The INFICON Pirani Capacitance Diaphragm Gauge (PCG55x) combines the INFICON Pirani technology with the advantages of a ceramic capacitance diaphragm sensor in a single product. In the measurement range

More information

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8

Programmable Set for Simple I/O Communication via PROFIBUS-DP in IP67 TI-BL67-PG-DP-S-8 Type designation Ident no. 1545097 Number of channels 8 Dimensions (W x L x H) 204 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 12 Mbps

More information

Product type designation. General information. Supply voltage

Product type designation. General information. Supply voltage Data sheet SIMATIC S7-300, CPU 313C-2DP COMPACT CPU WITH MPI, 16 DI/16 DO, 3 FAST COUNTERS (30 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 128 KBYTE WORKING MEMORY, FRONT CONNECTOR (1

More information

PCG550, PCG552, PCG554

PCG550, PCG552, PCG554 PCG550, PCG55, PCG554 Pirani Capacitance Diaphragm Gauge The INFICON Pirani Capacitance Diaphragm Gauge (PCG55x) combines the INFICON Pirani technology with the advantages of a ceramic capacitance diaphragm

More information

System Control Unit (SCU) for Burkert Process Instruments

System Control Unit (SCU) for Burkert Process Instruments System Control Unit (SCU) for Burkert Process Instruments Central control unit driving several control loops Gateway functionality with the following fieldbuses: ProfiNet, Ethernet-IP, Modbus-TCP Communication

More information

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW

Quick Start Guide PN/CAN-Gateway. Version. 1 en. from FW Quick Start Guide PN/CAN-Gateway Version 1 en from FW 1.00 www.helmholz.com Content 1. Introduction 3 2. Preparation of the PN/CAN-Gateway 3 3. Plan PN/CAN-Gateway 4 4. Configure PN/CAN-Gateway 5 5. Add

More information

. PC cards for all common fieldbus. systems Industrial Ethernet switches. . EtherCAT junctions and media converters in IP 20 and IP 67 ratings

. PC cards for all common fieldbus. systems Industrial Ethernet switches. . EtherCAT junctions and media converters in IP 20 and IP 67 ratings 610. Highlights. PC cards for all common fieldbus. systems. Industrial Ethernet switches. EtherCAT junctions and media converters in IP 20 and IP 67 ratings Infrastructure Components PC Fieldbus Cards,

More information

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath

IP67 VERSION BOX (on request) 8+3 PG9 cable glands-plugs. 8+3 PVC fittings for sheath Digital/analog weight transmitter suitable for back panel mounting on Omega/DIN rail or junction box for field mounting (on request box versions). Weighing system with 8 independent reading channels with

More information

CANopen IO X4 Fact sheet

CANopen IO X4 Fact sheet CANopen IO X4 Fact sheet Overview The CANopen IO X4 is a very compact and cost effective CANopen IO module featuring a high-density of industrial proven IO's. The module includes a CPU-core including the

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

Distributed Control I/O System ADAM-8000 Series

Distributed Control I/O System ADAM-8000 Series Distributed Control I/O System Series 16 Series Distributed Control I/O 16-2 Series Total Fieldbus Solution 16-4 CPU s ADAM8214-1BA01 PLC CPU214 16-6 ADAM8214-2BM01 PLC CPU214 with Profibus-DP Master 16-6

More information

Product type designation. General information. Supply voltage. Input current

Product type designation. General information. Supply voltage. Input current Data sheet SIMATIC S7-300, CPU 312C COMPACT CPU WITH MPI, 10 DI/6 DO, 2 FAST COUNTERS (10 KHZ), INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING MEMORY, FRONT CONNECTOR (1 X 40PIN) AND MICRO MEMORY CARD

More information

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual GW-7553-CPM PROFIBUS/CANopen GATEWAY User's Manual High Quality, Industrial Data Acquisition, and Control Products GW-7553-CPM PROFIBUS/CANopen GATEWAY User Manual (Version 1.00, Apr/2016) PAGE: 1 Warranty

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC

More information

BMKC Controller for Power Tower, 8 DI 8 DO 2 HSC

BMKC Controller for Power Tower, 8 DI 8 DO 2 HSC Characteristics Controller for Power Tower, 8 DI 8 DO 2 HSC Main Range of product Product or component type Product specific application Complementary Product compatibility [Us] rated supply voltage Current

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

Accessories Modular bus covers CANopen

Accessories Modular bus covers CANopen CANopen CAN_L CAN_H CAN_L CAN_H Features - CANopen Baud rate Terminal connector User address Cable:, = ø- mm (-- C) / ø- mm (-- C) Cable: = ø.- mm (-- C) / ø- mm (-- C) Connector M Cable gland CANopen

More information

Kit for Simple I/O Communication via Ethernet Modbus/TCP/ EtherNet/IP / PROFINET in IP67 TI-BL67-EN-S-8

Kit for Simple I/O Communication via Ethernet Modbus/TCP/ EtherNet/IP / PROFINET in IP67 TI-BL67-EN-S-8 Type code Ident no. 1545153 Number of channels 8 Dimensions (W x L x H) 204 x 145 x 77.5 mm A special software (function module) for integration in PLC systems is not required. Cable max. 50 m between

More information

Interface with: PROFIBUS, CANopen, DeviceNet, EtherNet/IP, PROFINET, EtherCAT Compatible with all Camozzi valve islands

Interface with: PROFIBUS, CANopen, DeviceNet, EtherNet/IP, PROFINET, EtherCAT Compatible with all Camozzi valve islands Valve Islands > 016 > Series CX multi-serial module Series CX multi-serial module New Interface with: PROFIBUS, CANopen, DeviceNet, EtherNet/IP, PROFINET, EtherCAT Compatible with all Camozzi valve islands»»

More information

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term

XPSMCMCO0000EM Modbus TCPIP diagnostic expansion module with screw term Characteristics Modbus TCPIP diagnostic expansion module with screw term Main Range of product Product or component type Device short name [Us] rated supply voltage Complementary Power dissipation in W

More information

Product type designation

Product type designation Data sheet SIMATIC DP, CPU 1512SP-1 PN FOR ET 200SP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 200 KB FOR PROGRAM AND 1 MB FOR DATA, 1. INTERFACE, PROFINET IRT WITH 3 PORT SWITCH, 48 NS BIT-PERFORMANCE,

More information

CANopen IO X2 Fact sheet

CANopen IO X2 Fact sheet CANopen IO X2 Fact sheet Overview The CANopen IO X2 is a very compact and cost effective CANopen IO module featuring a high-density of industrial proven I/O's. The module includes a CPU-core including

More information

VIPA HMI. Commander Compact CC 03 Manual

VIPA HMI. Commander Compact CC 03 Manual VIPA HMI Commander Compact CC 03 Manual HB116E_CC03 Rev. 15/04 January 2015 Copyright VIPA GmbH. All Rights Reserved. This document contains proprietary information of VIPA and is not to be disclosed or

More information

Operating and Monitoring Systems

Operating and Monitoring Systems Operating and Monitoring Systems System description System description Structure and Concept The VIPA Touch Panel with 5.7" to 12.1" display, Windows CE 5.0/6.0 and visualization system can be used universally.

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...

More information

DT7000 Communication I/O Gateway User s Guide Version 2.6

DT7000 Communication I/O Gateway User s Guide Version 2.6 DT7000 Communication I/O Gateway User s Guide Version 2.6 6 Clock Tower Place Suite 100 Maynard, MA 01754 USA Tel: (866) 837-1931 Tel: (978) 461-1140 FAX: (978) 461-1146 http://www.diamondt.com/ Liability

More information

Redundant System Redundant System P9-1-1

Redundant System Redundant System P9-1-1 .. P-- Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - P-- idcs-8830/idcs-8830r - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

More information

General information. Display. Control elements. Supply voltage

General information. Display. Control elements. Supply voltage Data sheet SIMATIC S7-1500F, CPU 1516F-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1,5 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET,

More information

The intelligent solution

The intelligent solution GATEWAY SERIES UNIGATE CM Easy installation Norm compliant Ready-to-use Configurable Designed & manufactured in Germany THE INTELLIGENT SOLUTION FOR: ETHERNET TCP/IP CAN/CANopen TO ALL FIELDBUSES AND INDUSTRIAL

More information

Product Description. Altus S. A. 1

Product Description. Altus S. A. 1 Product Description The PO5064 and PO5065 modules are Ponto Series modular PROFIBUS-DPV1 slave heads for PROFIBUS fieldbus that can use all I/O modules from this Series. They can be connected to HMIs (keyboards

More information

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7:

Parameterizable properties The S7 configuration as well as the properties and response of the CPUs can be parameterized using STEP 7: CPU 315-2 PN/DP Function Password protection; a password concept protects the user program from unauthorized access. Block encryption; the functions (FCs) and function blocks (FBs) can be stored in the

More information

General information. Configuration control. Display. Control elements. Supply voltage

General information. Configuration control. Display. Control elements. Supply voltage Data sheet SIMATIC S7-1500, CPU 1516-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE:

More information

TB20. DISTRIBUTED FIELDBUS I/O SYSTEM

TB20. DISTRIBUTED FIELDBUS I/O SYSTEM TB20. DISTRIBUTED FIELDBUS I/O SYSTEM With the TB20 I/O system you generate efficient and functional added value for a variety of application areas irrespective of the fieldbus and proven in practice!

More information

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss

General information. Configuration control. Display. Control elements. Supply voltage. Input current. Power. Power loss Data sheet SIMATIC S7-1500, CPU 1516-3 PN/DP, CENTRAL PROCESSING UNIT WITH WORKING MEMORY 1 MB FOR PROGRAM AND 5 MB FOR DATA, 1. INTERFACE: PROFINET IRT WITH 2 PORT SWITCH, 2. INTERFACE: ETHERNET, 3. INTERFACE:

More information

Product Specification

Product Specification Product Specification MLC 9000+ Basic Bus Module The Basic Bus Module is part of the MLC 9000+ DIN-Rail mounting multiple loop PID control system. The Basic Bus Module is the supervisor in the MLC 9000+

More information

Remote I/O Product Specification

Remote I/O Product Specification Table of Contents 1. Product Overview... 1 1.1 Product List:... 1 1.1.1 Coupler List:... 1 1.1.2 Digital I/O List:... 1 2. Fieldbus Coupler... 2 2.1 CANopen Specifications... 2 2.2 Ethernet TCP/IP Specifications...

More information

PSG550, PSG552, PSG554

PSG550, PSG552, PSG554 PSG550, PSG55, PSG554 Pirani Standard Gauge The INFICON Pirani Standard Gauge (PSG55x) employs like his brothers PCG55x and PSG50x the most advanced digital Pirani technology available. The rugged sensor

More information

UNIGATE CL. Protocol Converter. A solution for all devices with a serial interface. Easy installation. Norm compliant. Ready-to-use.

UNIGATE CL. Protocol Converter. A solution for all devices with a serial interface. Easy installation. Norm compliant. Ready-to-use. ProtoCol Converter UNIGATE CL Easy installation Norm compliant Ready-to-use Configurable Programmable Designed & manufactured in Germany The intelligent Protocol Converter for ETHERNET TCP/IP A solution

More information

VIPA System SLIO. IM 053-1EC01 Manual. HB300 IM 053-1EC01 en Interface module EtherCAT - IM 053EC.

VIPA System SLIO. IM 053-1EC01 Manual. HB300 IM 053-1EC01 en Interface module EtherCAT - IM 053EC. VIPA System SLIO IM 053-1EC01 Manual HB300 IM 053-1EC01 en 18-45 Interface module EtherCAT - IM 053EC www.vipa.com/en/service-support/manuals VIPA GmbH Ohmstr. 4 91074 Herzogenaurach Telephone: +49 9132

More information

Motor controllers CMMO-ST

Motor controllers CMMO-ST q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity qready for dispatch

More information

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved. Modules SCOPE Repeater Module Name 1 Channel RS 485 SCOPE Repeater Type 1 Order code 101 201210 Description 1 Channel RS 485 PROFIBUS SCOPE repeater module with integrated quality oscilloscope for 12 Mbps

More information

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory. Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING

More information

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design

More information

CAN 300 PRO, Communication Module

CAN 300 PRO, Communication Module 90 Communication Modules CAN 300 PRO, Communication Module Layer 2, 11 Bit and 29 Bit (CAN 2.0 A/B) on the module DIP switch for adress + baud rate Micro Memory Card for saving a project (optional) USB

More information

Lexium 05 motion control

Lexium 05 motion control Characteristics Environmental characteristics Conformity to standards have been developed to conform to the strictest international standards and the recommendations relating to electrical industrial control

More information

CANopen IO X1 Fact sheet

CANopen IO X1 Fact sheet CANopen IO X Fact sheet Overview The CANopen IO X is a very compact and cost effective CANopen IO module featuring a high-density of industrial proven I/O's. The module includes a CPU-core including the

More information

Main Catalog 2012/2013 for specialists in automation and control technology

Main Catalog 2012/2013 for specialists in automation and control technology Main Catalog 2012/2013 for specialists in automation and control technology www.vipa.com Welcome to VIPA This is VIPA Specialists in automation and control systems. Developer in some to the most advanced

More information

Fieldbus BC (CANopen), BP (PROFIBUS DP), EH (EtherCAT), EW (POWERLINK), EI (EtherNet/IP), EP (PROFINET IRT)

Fieldbus BC (CANopen), BP (PROFIBUS DP), EH (EtherCAT), EW (POWERLINK), EI (EtherNet/IP), EP (PROFINET IRT) Table GS510-3/E Fieldbus BC (CANopen), BP (PROFIBUS DP), EH (EtherCAT), EW (POWERLINK), EI (EtherNet/IP), EP (PROFINET IRT) Typical CANopen or PROFIBUS DP fieldbus network Fieldbus communication interfaces

More information

HMG 11. Features. Optional Additional incremental output (TTL / HTL) HMG 11. Technical data - mechanical design. Technical data - electrical ratings

HMG 11. Features. Optional Additional incremental output (TTL / HTL) HMG 11. Technical data - mechanical design. Technical data - electrical ratings Features Multiturn / SSI / Profibus / CANopen / DeviceNet / PROFINET Optical sensing method Singleturn 1 bit, multiturn 1 bit / 16 bit Blind or through hollow shaft or cone shaft ø16-0 mm Multiturn sensing

More information

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings

AMG 11. Features. Optional. Additional incremental output (TTL / HTL) AMG 11. Technical data - mechanical design. Technical data - electrical ratings Features Multiturn SSI / Profibus / CANopen / DeviceNet / PROFINET Optical sensing method Singleturn 1 bit, multiturn 1 bit / 16 bit EURO-flange B10 / solid shaft ø11 mm Multiturn sensing with microgen

More information

POINT I/O Family. Chapter. Overview

POINT I/O Family. Chapter. Overview Chapter 1 POINT I/O Family Overview The POINT I/O family has modular I/O modules that are ideal for applications where flexibility and low-cost of ownership are key for successful control system design

More information

VersaMax IP Input Module

VersaMax IP Input Module Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm

More information

UNIGATE UNIGATE ALL-IN-ONE BUS NODE 32 DIL. Norm compliant. Certified. Programmable. Designed & manufactured in Germany. READY-TO-INSTALL for MPI

UNIGATE UNIGATE ALL-IN-ONE BUS NODE 32 DIL. Norm compliant. Certified. Programmable. Designed & manufactured in Germany. READY-TO-INSTALL for MPI UNIGATE ALL-IN-ONE BUS NODE UNIGATE IC IC 32 DIL Norm compliant Certified Programmable Designed & manufactured in Germany READY-TO-INSTALL for ETHERNET TCP/IP MPI Integrate with little development effort

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

ZigBee is a specification based on the IEEE standard for wireless personal area networks (WPANs).

ZigBee is a specification based on the IEEE standard for wireless personal area networks (WPANs). 1. Introduction ZigBee is a specification based on the IEEE 802.15.4 standard for wireless personal area networks (WPANs). ZigBee operates in the ISM radio bands and its focus is to define a general-purpose,

More information

Fieldbus Gateway Type ME43

Fieldbus Gateway Type ME43 Fieldbus Gateway Type ME43 Gateway for Industrial Ethernet and Fieldbus standards Up to 128 input and 128 output variables can be assigned Easy integration in the process control system ensured through

More information

crio PN Installation Instructions V0.2/ COMSOFT

crio PN Installation Instructions V0.2/ COMSOFT crio PN Installation Instructions V0.2/10.06.2015 COMSOFT crio PN-Installation- V0.2/10.06.2015 i:\icp\project\700391_crio_pn\anwenderdoku\installation\version_0.2\crio_pn_e.doc Revision History Version

More information

AC 800M for Compact Product Suite Outline of all modules

AC 800M for Compact Product Suite Outline of all modules DATA SHEET AC 800M for Compact Product Suite Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose

More information

UNIGATE CL CL. Protocol Converter. A solution for all devices with a serial interface. Easy installation. Norm compliant. Ready-to-use.

UNIGATE CL CL. Protocol Converter. A solution for all devices with a serial interface. Easy installation. Norm compliant. Ready-to-use. UNIGATE ProtoCol Converter UNIGATE CL CL Easy installation Norm compliant Ready-to-use Configurable Programmable Designed & manufactured in Germany The intelligent Protocol Converter for ETHERNET TCP/IP

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information