6Gb/s SAS JBOD enclosure
|
|
- Kory Morrison
- 6 years ago
- Views:
Transcription
1
2 6Gb/s SAS JBOD enclosure Version:First Edition Issue Date:Jan. 2011
3 SAFETY PRECAUTIONS Please read this section carefully before proceeding. These precautions explain the correct and safe use of this device, thereby helping to prevent injury to you or others, and also help you to minimize the risk of damaging the device. Warnings Always follow the basic warnings listed here to avoid the risk of serious injury or death from electrical shock, short-circuiting, fire, and other hazards. These warnings include, but are not limited to: With the exception of the user-swappable parts, do no attempt to disassemble or modify the enclosure. If this device appears to be malfunctioning, contact Netstor Customer Service. Do not drop the enclosures or any of its drive modules; dropping or mishandling of the enclosure or drive modules may result in a malfunction. Do not insert your fingers or foreign objects inside the enclosure; take particular care when small children are present. Do not expose the device to rain, use it near water or containers that contain liquids which might spill into any openings, or in damp or wet conditions. If unusual smells, sounds, or smoke come from the device, or if liquids enter it, switch it off immediately and unplug it from the electrical outlet. Follow the instructions in this manual carefully; contact Netstor Customer Service for additional advice not covered in this User s Guide.
4 Table of contents 1. Introduction P2 1.1 Overview P2 1.2 Package Checklist P2 2. Hardware Installation P3 2.1 Panel Layout P3 2.2 Enclosure Setup P8 3. LCD Configuration Manager P Using local front panel touch-control keypad. P Navigation Map of the LCD P13 4. CLI Manager P Expander RS-232C Port Pin Assignment P Start-up VT100 Screen P CLI Command P21 HELP Command P21 PASS Command P22 LO Command P22 LINK Command P23 GROUP Command P25 SYS Command P27 SPIN Command P28 ST Command P29 LSD Command P29 SHOWLOGS Command P31 FDL Command P32 FAN Command P34 Netstor 1
5 Introduction 1. Introduction 1.1 Overview Netstor s enterprise-class 6Gb/s SAS Expander JBOD series is designed to provide storage expansion for 6/3Gbps SAS RAID controller or 6/3Gbps SAS RAID adapter (SAS HBA). The enclosure is equipped with 6Gbps SAS Expander supporting eight, twelve, and sixteen high-reliable SAS 6/3Gbps or high-capacity SATA 6/3Gbps drives, with only one single mini-sas cable host connectivity, and provides two mini-sas ports allowing you to expand more 6Gb/s SAS JBOD enclosures, ensuring it the most cost-effective storage expansion. 1.2 Package Checklist NS330S-8026 Before the installation of the enclosure, verify the items below are included in the package. A. Enclosure 1 B. HDD tray (installed in the NS330S-8026) 16 C. CD containing user s manual 1 D. Hard disk drive mounting screw 64 E. Key for HDD tray 2 F. mini-sas (SFF-8088) to mini-sas (SFF-8088) data cable (optional) 1 If any of the items listed above is missing or damaged, please contact the sales representative. NS320S-8026 Before the installation of the enclosure, verify the items below are included in the package. A. Enclosure 1 B. HDD tray (installed in the NS320S-8026) 12 C. CD containing user s manual 1 D. Hard disk drive mounting screw 48 E. Key for HDD tray 2 F. mini-sas (SFF-8088) to mini-sas (SFF-8088) data cable (optional) 1 If any of the items listed above is missing or damaged, please contact the sales representative. 2 Netstor
6 Hardware Installation NS765S Before the installation of the enclosure, verify the items below are included in the package. A. Enclosure 1 B. HDD tray (installed in the NS765S) 8 C. CD containing user s manual 1 D. Hard disk drive mounting screw 32 E. Key for HDD tray 2 F. mini-sas (SFF-8088) to mini-sas (SFF-8088) data cable (optional) 1 If any of the items listed above is missing or damaged, please contact the sales representative. 2. Hardware Installation This section gives the layout of the panel and describes the procedures for setting up the 6Gb/s SAS JBOD enclosure. 2.1 Panel Layout NS330S LCD display 2. Enclosure power LED Green Power On 3. Busy LED Flash green Host computer accessing the enclosure 4. Fault LED Red Enclosure failure 5. LCD control keypad 6. Drive presence LED White Power On Netstor 3
7 Hardware Installation 7. Activity indicator LED Blue Hard disk drive ready Flash Blue Access Flash Pink Rebuilding Red Hard disk failure 8. Power switch button 9. Power supply alarm mute button 10. Power cord receptacle 11. SAS Exp. out connector 12. SAS Exp. in connector 13. SAS Exp. out connector 14. Activity LED Blue When activity LED illuminates, it indicates SAS host accesses to NS330S Link LED Green When host port link LED illuminates for 1 second and light off for 3 seconds, it indicates one link has connected. When host port link LED illuminates for 2 seconds and light off for 2 seconds, it indicates two links have connected. When host port link LED illuminates for 4 seconds, it indicates four links have connected. 16. RS-232 port for CLI configuration 17. Fan Fan Fan Fan 4 NS320S Drive presence LED White Power On 2. Activity indicator LED 4 Netstor
8 Hardware Installation Blue Hard disk drive ready Flash Blue Access Flash Pink Rebuilding Red Hard disk failure 3. Power switch button 4. Power supply alarm mute button 5. Power cord receptacle 6. Enclosure power LED Green Power On 7. Busy LED Flash green Host computer accessing the enclosure 8. Fault LED Red Enclosure failure 9. LCD display 10. LCD control keypad 11. SAS Exp. out connector 12. SAS Exp. in connector 13. SAS Exp. out connector 14. Activity LED Blue When activity LED illuminates, it indicates SAS host accesses to NS320S Link LED Green When host port link LED illuminates for 1 second and light off for 3 seconds, it indicates one link has connected. When host port link LED illuminates for 2 seconds and light off for 2 seconds, it indicates two links have connected. When host port link LED illuminates for 4 seconds, it indicates four links have connected. 16. RS-232 port for CLI configuration 17. Fan Fan Fan Fan 4 Netstor 5
9 Hardware Installation NS765S 1. LCD display 2. System power LED Green Power On 3. Busy LED Flash green Host computer accessing the enclosure 4. Fault LED Red Enclosure failure 5. LCD control keypad 6. Enclosure power LED White Power On 7. Fan LED Green Normal Red Failure (low frequency of RPM or stop) 8. Temperature LED Green Normal Red Overheated (higher than 55 ) 9. Buzzer mute button 10. Drive presence LED White Power On 11. Activity indicator LED Blue Hard disk drive ready Flash Blue Access Flash Pink Rebuilding Red Hard disk failure 12. SAS Exp. out connector 13. SAS Exp. in connector 14. SAS Exp. out connector 15. Link LED Green When host port link LED illuminates for 1 second and light off for 3 seconds, it indicates one link has connected. 6 Netstor
10 Hardware Installation When host port link LED illuminates for 2 seconds and light off for 2 seconds, it indicates two links have connected. When host port link LED illuminates for 4 seconds, it indicates four links have connected. 16. Activity LED Blue When activity LED illuminates, it indicates SAS host accesses to NS765S. 17. RS-232 port for CLI configuration 18. Swappable fan 19. Power cord receptacle 20. Power switch button NOTE: 1. When one of the fans breaks down, the buzzer inside the 6Gb/s SAS JBOD enclosure will beep. For NS330S-8026 and NS320S-8026, to mute the beep, select Set Alarm from the LCD display, and then enter the password After you enter the password, select Mute Beep and press enter to mute the beep. The other way to mute the beep is to click the mute button from the GUI interface. For NS765S, to mute the beep, press the mute button on the front panel. 2. For NS330S-8026 and NS320S-8026, when one of the two power supply units breaks down, both buzzers of the power supply and enclosure will beep. To mute the beep from the power supply, press the green alarm mute button on rear of the enclosure. And to mute the beep from the enclosure, select Set Alarm from the LCD display, and then enter the password After you enter the password, select Mute Beep and press enter to mute the beep. The other way to mute the beep from the enclosure is to click the mute button from the GUI interface. Netstor 7
11 Enclosure Setup 2.2 Enclosure Setup 1. Remove the 6Gb/s SAS JBOD enclosure from its packaging, and place the enclosure next to desktop PC, server, or workstation. 2. Hold one of the drive trays from the enclosure and push its button leftward for the release of the lever until the lever pops out. 3. Place a drive tray on a flat and level surface, and then attach the hard disk drive into the drive tray. WARNING: You must verify the heads of the four screws are level with the drive tray while the trays are attached to the hard disk drives; otherwise, a screw could take hold of the tray from the bottom side and prevent you to pull the drive tray out of the array. 4. Adopt four of the screws provided, and fasten the tray on the hard disk drive. Tighten each screw to fasten the drive tray snugly to the hard disk drive. Do not tighten the screws overly. WARNING: Do not force the levers to close while you insert drive modules into the 6Gb/s SAS JBOD enclosure. If a lever does not close smoothly, draw out and insert the drive module again, and then press the lever to close. 8 Netstor
12 Enclosure Setup 5. Insert the drive module into the 6Gb/s SAS JBOD enclosure correctly until its lever appears to shut, and then press the lever to close until it clicks to ensure that the drive module is within the enclosure. 6. Repeat steps 2 to 5 for further drives. 7. Connect 6Gb/s SAS JBOD enclosure to the host interface: a host adapter or RAID controller card through the SFF-8088 SAS cable. Connection between 6Gb/s SAS JBOD enclosure and host adapter port is shown below: 8. Connecting 6Gb/s SAS JBOD enclosure s RS-232 Port (optional) 6Gb/s SAS JBOD enclosure s system functions can be managed via a PC running a VT-100 terminal emulation program, or a VT-100 compatible terminal. The provided internal cable converts the RS-232C signals from the RJ11 into the one 9-pin D-Sub male connector. 9. Add more 6Gb/s SAS JBOD enclosures (optional) 6Gb/s SAS JBOD enclosure can be run in one of the two modes: Normal Mode Zone Mode Netstor 9
13 Enclosure Setup You must select either mode using the CLI utility and re-start the 6Gb/s SAS JBOD enclosure. The default is Normal Mode. Change the mode while 6Gb/s SAS JBOD enclosure is on. This will not affect expander operation until 6Gb/s SAS JBOD enclosure is rebooted. In normal mode, a SAS host can communicate with all drives in 6Gb/s SAS JBOD enclosure. 6Gb/s SAS JBOD enclosure contains expander ports. Expander ports can be attached to SAS initiator ports, SAS and/or SATA target ports, and other expander ports. The SAS RAID controller card or host adapter supports daisy-chain. The number of the 6Gb/s SAS JBOD enclosures that can be supported depends on the RAID controller card or the host adapter firmware. The following figure shows the connections of 6Gb/s SAS JBOD enclosures with external mini-sas data cables and SAS RAID controller card. In zone mode, 6Gb/s SAS JBOD enclosure can be split into up to 8 virtual groups. Each group s drive channels and external cable connectors are assigned by CLI GROUP command. The following figure shows 6Gb/s SAS JBOD enclosure that is split into 2 virtual groups. Each group s drive channels are controlled by individual host adapter using SAS CH1 and SAS CH2. 10 Netstor
14 Note: LCD Configuration Manager 1. Please refer to chapter 4.3 CLI features of GROUP command which is used to associate the external port and the devices/phys slot. 2. The first thing is to turn on 6Gb/s SAS JBOD enclosure to make sure the SAS RAID controller or SAS host adapter recognizes the drives in the enclosure. 10. As 6Gb/s SAS JBOD enclosure provides redundant power supply unit, connect one end of the two power cords to the two receptacles on rear of 6Gb/s SAS JBOD enclosure, and then connect the other end of the two power cords to the outlets. 11. After the two power cords are connected, you can switch on 6Gb/s SAS JBOD enclosure and the computer. 3. LCD Configuration Manager The 6Gb/s SAS JBOD enclosure LCD configuration utility is a character-based utility that you can run after powering the unit. Use LCD configuration utility to see and configure: Alarm Device, Voltage, Set Link, Set Alarm, Set Password, Save Config, and System Reset The LCD display front panel function keys are the primary user interface for 6Gb/s SAS JBOD enclosure. Except for the "Firmware update", all configurations can also be performed through this interface. Netstor 11
15 Using Local Front Panel Touch-Control Keypad 3.1 Using Local Front Panel Touch-Control Keypad The front panel keypad and liquid crystal display (LCD) is the primary user interface for 6Gb/s SAS JBOD enclosure. All configuration and management of the expander controller and its properly connected disk arrays can be performed from this interface. The front panel keypad and LCD is to access the built-in configuration that resides in the 6Gb/s SAS JBOD enclosure s firmware. The LCD provides a system of screens with areas for information, status indication, or menus. The LCD screen displays up to two lines at a time of menu items or other information. The initial screen is shown as following: Function Key Definitions: The four function keys at the right of the front panel perform the following functions: Key Up Arrow Down Arrow ENT Key ESC Key Function Use to scroll the cursor Upward / Rightward Use to scroll the cursor Downward / Leftward Submit selected icon function (Confirm a selected item) Return to previous screen (Exit a selection configuration) There are a variety of failure conditions that cause 6Gb/s SAS JBOD enclosure monitoring LED to light. Below table provides a summary of the front panel LED. 12 Netstor
16 Navigation Map of the LCD Panel LED Normal Status Problem Indication Power LED Busy LED (Host Access) Bright green Blink green during host computer accessing 6Gb/s SAS JBOD enclosure This LED does not light up after power switched on LED never flickers Fault LED Unlit Solid red 3.2 Navigation Map of the LCD The password option allows user to set or clear 6Gb/s SAS JBOD enclosure s password protection feature. Once the password has been set, the user can only monitor and configure 6Gb/s SAS JBOD enclosure by providing the correct password. The password is used to protect 6Gb/s SAS JBOD enclosure from unauthorized entry. 6Gb/s SAS JBOD enclosure will check the password only when entering the main menu from the initial screen. 6Gb/s SAS JBOD enclosure will automatically go back to the initial screen when it does not receive any command in 5 minutes. 6Gb/s SAS JBOD enclosure s default password is The following flow is an expansion of LCM setup option items hierarchical menu. Netstor 13
17 Navigation Map of the LCD LCM setup option items hierarchical menu: 14 Netstor
18 Navigation Map of the LCD Alarm Device Show which device that fail to work, its sub-items could be "Power Supply", "Fan", "Temp. Sensor" and "Voltage Sensor". Voltage Show enclosure chip voltage in status data, represent in V. The sub-items are shown as below: 1.2V-, 6Gb/s SAS JBOD enclosure voltage is 1.2V 5V-, 6Gb/s SAS JBOD enclosure voltage is 5V For the setup item, the LCM keys represent: Up key to enter the 0-9 data. Down key to enter "a" - "z" and "A" - "Z" data. Enter key to confirm the input or ready to update a sub-item data. Esc / Exit key to go back to the main selection. Set Link Set HDD devices maximun/minimun link speed rate. the value could be 6.0G, 3.0G or 1.5G each of HDD devices link speed will have the sub-items are shown as below: _Set Max. Rate 6.0G _Set Min. Rate 1.5G Set Alarm Set enclosure buzzer warning/critical error beep style or mute the current beep. The value could be "Sound 1", "Sound 2", "Sound 3", "Sound 4" and "Sound Disabled". Sound 1 to 4 means different frequency sound. Sound disabled means disable the sound beep. The sub-items are shown below: _Set Alarm Beep Mute beep Warning Alarm _Sound 2 _Critical Alarm Sound 3 Netstor 15
19 CLI Manager Set Password Change the enclosure LCM/UART CLI password. The sub-item is "Set New PWD". Save Config Save all the updated option value into non-volatile memory area. System Reset Reboot the system. 4. CLI Manager This Command Line Interface (CLI) is provided for you to manage the 16 SAS expander system functions. The CLI is useful in environments where a graphical user interface (GUI) is not available. Locations of RS-232C Port 6Gb/s SAS JBOD enclosure uses the RJ11 port as the serial port interface. Please use the cable included on the shipping box to configure the expander controller. Establishing the Connection for the RS-232 Port The CLI function can be done by using an ANSI/VT-100 compatible terminal emulation program. You must complete the appropriate installation procedure before proceeding with the CLI function. Whichever terminal emulation program is used must support the 1K XMODEM file transfer protocol. The serial port on 6Gb/s SAS JBOD enclosure s bracket can be used in VT100 mode. The provided interface cable converts the RS232 signal of the RJ11 connector on the SAS expander controller into a 9-pin D-Sub male connector. The firmware-based terminal SAS expander management interface can access the expander through this RS-232 port. You can attach a VT-100 compatible terminal or a PC running a VT-100 terminal emulation program to the serial port for accessing the text-based setup menu. 16 Netstor
20 4.1 Expander RS-232C Port Pin Assignment Expander RS-232C Port Pin Assignment To ensure proper communications between 6Gb/s SAS JBOD enclosure and the VT-100 Terminal Emulation, Please configure the VT100 terminal emulation settings to the values shown below: Terminal requirement Connection Null-modem cable Baud Rate 115,200 Data bits 8 Stop 1 Flow Control None The controller RJ11 connector pin assignments are defined as below. Action Pin Description Pin Description 1 RTS 3 TXD 2 RXD 4 GND 4.2 Start-up VT100 Screen By connecting a VT100 compatible terminal, or a PC operating in an equivalent terminal emulation mode, all CLI administration functions can be exercised from the VT100 terminal. There are a wide variety of Terminal Emulation packages, but for the most part they should be very similar. The following setup procedure is an example Setup VT100 Terminal in Windows XP system using Hyper Terminal use Version 3.0 or higher. Netstor 17
21 Expander RS-232C Port Pin Assignment Step 1. Open the Taskbar Start / Programs" / "Accessories" / "Commmunications" / "Heyper Terminal". (Heyper Terminal requires version 3.0 or higher). Step 2. Open HYPERTRM.EXE. 18 Netstor
22 Step 3. Enter a name you prefer and then click OK. Expander RS-232C Port Pin Assignment Step 4. Select an appropriate connecting port and then click "OK". Step 5. Configure the port parameter settings and then click OK. Bits per second: Data bits: 8 Parity: None Stop bits: 1 Flow control: None Netstor 19
23 Expander RS-232C Port Pin Assignment Step 6. Open the file menu and select Properties. Step 7. Configure the "Connect To" setting. 20 Netstor
24 CLI Command Step 8. Configure the "Settings" items and then click "OK". Function, arrow and ctrl keys act as: Terminal Keys Backspace key sends: Crtl+H Emulation: VT100 Telnet terminal: VT100 Back scroll buffer lines: CLI Command This section provides detailed information about 6Gb/s SAS JBOD enclosure s CLI function. All the commands please type in lower case. HELP Command This command provides an on-line table of contents, providing brief descriptions of the help sub-commands. You can use the <CLI> help to get detail information about the CLI commands summary. Syntax CLI>help[Enter] Example: CLI>help pass lo link - Set Password - Logout CLI Shell - Link Rate Control Netstor 21
25 CLI Command group sys spin st lsd showlogs fld - Set the PHY Group - System Information - Drive SpinUp Control - Store System Setting - List Devices Status - Show the Current Logs - File Download PASS Command The pass command allows user to set or clear 6Gb/s SAS JBOD enclosure password protection feature. Once the password has been set, the user can only monitor and access 6Gb/s SAS JBOD enclosure setting by providing the correct password. The password can accept max. 8 chars and min. 4 chars. The manufacture default password is Syntax CLI>pass [Enter] Example: CLI>pass Old Password:**** New Password:**** Verify New Password:**** Password Changed But Not Save Permanently! Note, use CLI command st to keep permanently. LO Command To exit the selected 6Gb/s SAS JBOD enclosure CLI shell, use the lo command. Syntax CLI> lo [Enter] Example: CLI>lo Password: 22 Netstor
26 CLI Command LlNK Command The link command allows you to set the operational device link rate with the enclosure. Typical parameters include: Max and Min disk speed with 6Gb/s SAS JBOD enclosure. Syntax CLI>link [Index Max Min] [Enter] Index: Slot Index Max, Min: speed code, 8 means 1.5G, 9 means 3.0G and 10 means 6.0G PS. Pls. Save Config. & Reboot To Take Effect CLI>st Example: CLI>link ArrayDevice Element (0x17): ======================================================================== NAME PHY NLR MAX MIN TYPE ADDRESS SLOT G 10 8 SAS 5000C500-0D2002D1 SLOT SLOT SLOT G 10 8 SATA 5001B C03 SLOT SLOT SLOT G 10 8 SAS 5000C500-17C8FD25 SLOT SLOT SLOT SLOT SLOT //Set the slot 0x6 max. speed to 1.5G CLI >link CLI >link Netstor 23
27 CLI Command ArrayDevice Element (0x17): ======================================================================== NAME PHY NLR MAX MIN TYPE ADDRESS SLOT G 10 8 SAS 5000C500-0D2002D1 SLOT SLOT SLOT G 10 8 SATA 5001B C03 SLOT SLOT SLOT G 90 8 SAS 5000C500-17C8FD25 SLOT SLOT SLOT SLOT SLOT CLI>st CLI> Reboot to take effect. CLI >link ArrayDevice Element (0x17): ======================================================================== NAME PHY NLR MAX MIN TYPE ADDRESS SLOT G 10 8 SAS 5000C500-0D2002D1 SLOT SLOT SLOT G 10 8 SATA 5001B C03 SLOT SLOT SLOT G 9 8 SAS 5000C500-17C8FD25 SLOT SLOT Netstor
28 CLI Command SLOT SLOT SLOT GROUP Command The group command is used to associate the external port with the devices/phys as one zone group. The three external cable ports and all devices/phys slots will default associate with one zone group. Syntax gr {dev GroupNo[1..] {ci, cj, ck,..} Start-Index(D) End-Index(D)} gr {off [t10 off] } dev : use drive slot index GroupNo : groupno start from 1, max 8 groups ci, cj, ck,..: external cable connector. i, j, k,.. is the index which range from 0 to 3. According to view from connector side, index start from right to left or top to bottom. The cable c0, c1, or c2 is view from right to left or start from top to bottom. Start-Index : Start slot index of zone range, [1.. max drive] End-Index : End slot index of zone range, [1.. max drive] off : clear the zone group setting. t10 off : turn T10 mode off. Example: CLI>gr Current PHY Group Mode: T10 Group-1: C0, C1, C2, Slot: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Value: 0x FFFFFFFFF //Set the cable0 and slot 1 to slot 6 as group 1 CLI>gr dev 1 c0 1 6 New PHY Group Mode: T10 Group-1: C0, Slot: 1, 2, 3, 4, 5, 6 Value: 0x FFC00 Netstor 25
29 CLI Command Current PHY Group Mode: T10 Group-1: C0, C1, C2 Slot: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Value: 0x FFFFFFFFF //Set the cable1 and cable2 and slot 7 to slot 16 as group 2 CLI>gr dev 2 c1, c New PHY Group Mode: T10 Group-1: C0, Slot: 1, 2, 3, 4, 5, 6 Value: 0x FFC00 Group-2: C1, C2, Slot: 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Value: 0x FF003FF Current PHY Group Mode: T10 Group-1: C0, C1, C2 Slot: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Value: 0x FFFFFFFFF CLI>st Power Cycle to reboot CLI>gr Current PHY Group Mode: T10 Group-1: C0, Slot: 1, 2, 3, 4, 5, 6 Value: 0x FFC00 Group-2: C1, C2, Slot: 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Value: 0x FF003FF //Clear the Zone group Setting CLI>gr off 26 Netstor
30 CLI Command New PHY Group Mode: T10 Group-1: C0, C1, C2 Slot: 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Value: 0x FFFFFFFFF Current PHY Group Mode: T10 Group-1: C0, Slot: 1, 2, 3, 4, 5, 6 Value: 0x FFC00 Group-2: C1, C2, Slot: 7, 8, 9, 10, 11, 12, 13, 14, 15, 16 Value: 0x FF003FF SYS Command The sys command is used to view the information of 6Gb/s SAS JBOD enclosure. Typical information includes: vendor, model name, serial/unit number, expander port number, product revision, chip name/chip revision, customer code, manufacture data revision and work time. Syntax CLI>sys [Enter] Example: CLI>sys ======================================== ======================================== Hardware Revision Information:- ======================================== ======================================== Vendor ID : Netstor Technology Co Ltd. Taiwan, R.O.C. Model ID : NS330S Serial No. : Unit Serial No. : Expander SAS Address : 0x5001B C3F Product Revision : 0 Netstor 27
31 CLI Command Exapnder Chip ID : 0x0221 (Ports : 28) Exapnder Chip Revision : B3 Customer Code : 0x36 Manufacturer Data Revision : 0xB2 Wroking Time : Day :48:14 ======================================== ======================================== Firmware Revision Information:- ======================================== ======================================== Active Firmware: Active Image Boot Image: Revision: /30/10 Firmware Family: 1 Fast Boot: No Image Address: 0x Active Image: Revision: /30/10 Firmware Family: 1 Fast Boot: No Image Address: 0x Backup Image: Revision: /30/10 Firmware Family: 1 Fast Boot: No Image Address: 0x SPIN Command The spin command defines the mode of staggering SATA drive spin-up function connected to 6Gb/s SAS JBOD enclosure. This command gives 6Gb/s SAS JBOD enclosure the ability to spin up the disk drives sequentially or in groups, allowing the drives to come ready at the optimum time without straining the system power supply. Staggering drive spin-up in a multiple drive environment also avoids the extra cost of a power supply designed to meet short-term startup power demand as well as: Syntax CLI> spin [ Delay(D)[ms] Num(D) ] Expander issues the spin up the drives by [ Num] drives with 28 Netstor
32 CLI Command [Delay] ms. Example1: CLI>spin Current SpinUp Attribute: Drive Number: 1 Delay: 1024 ms CLI>spin New SpinUp Attribute: Drive Number: 3 Delay: 512 ms Current SpinUp Attribute: Drive Number: 1 Delay: 1024 ms ST Command The st command stores system configurations in flash. Since all the revised parameter setting is temporarily stored in the working RAM, the ST command saves those parameters permanently in flash ROM. Syntax CLI> st Example: CLI> st CLI> LSD Command The lsd command is use for show the element devices status in the expander controller. With parameter, this command only shows the seletct device status. Syntax CLI> lsd [ hdd temp volt pwr con..] Show SES elements information: Netstor 29
33 CLI Command ArrayDevice Element (0x17): ======================================================================== NAME PHY NLR MAX MIN TYPE ADDRESS SLOT G 10 8 SAS 5000C500-0D2002D1 SLOT SLOT SLOT G 10 8 SATA 5001B C03 SLOT SLOT SLOT G 10 8 SAS 5000C500-17C8FD25 SLOT SLOT SLOT SLOT SLOT Connector Element (0x19): ======================================================================== NAME PHY NLR TYPE STATUS Connector Connector Connector Connector Connector G 02 Connected Connector G 02 Connected Connector G 02 Connected Connector G 02 Connected Connector Connector Connector Connector Cooling Element (0x03): 30 Netstor
34 CLI Command ======================================================================== NAME SPEED CODE RPM STATUS Fan OK Fan OK Fan 03 Fan 04 Not-Installed Not-Installed Temperature Element (0x04): ======================================================================== NAME ID CT( C) HTW LTW OTWarn ENC. Temp No Chip Temp No Voltage Element (0x12): ======================================================================== NAME VOLT(V) OVLMT UVLMT STATUS 1V None 5V None PowerSupply Element (0x02): ======================================================================== NAME PowerSupply01 PowerSupply02 STATUS OK OK AudibleAlarm Element (0x06): ======================================================================== NAME STATUS ALMSTATE Audible-Alarm Normal 0 CLI> SHOWLOGS Command The showlogs command allows you to display system event notifications that have been generated by 6Gb/s SAS JBOD enclosure. Syntax CLI>showlogs [DisplayMode(hex, detail, default)] Example: Netstor 31
35 CLI Command CLI>showlogs :PLATFORM:Firmware initialization started Day :00:00 ENCLOSURE-Fan 01 Failed FDL Command 6Gb/s SAS JBOD enclosure has added the expander firmware update through the CLI on the external RS-232 port. Before you process the firmware update, there are two block regions that you can update expander microcode on 6Gb/s SAS JBOD enclosure. (1)CODE region - for FW file : sas2xfwxxxx.fw (2)MFGB region - for Data file : mfgdat6gyyyy.rom To update the expander controller firmware, follow the procedure below: Syntax: all the commands please type in lower case CLI>fdl { code mfgb } offset[enter] Then use XModem/(Checksum) protocol transmit file to update ROM Region The following procedures are used to update firmware through the RS-232: A. Open any UART communication tools like HypeTerminal(115200,n,8,1). B. Press any key on HyperTerminal window, the window will show CLI> prompt. C. Type help will show help screen. D. One command to update firmware. Step as follow, E. Issue download & update command under CLI>. CLI>fdl code 0 Please Use XModem Protocol for File Transmission. Use Q Or q to quit Download before starting XModem. <-----expander prompt for ready to receive file to update. F. Then under HyperTerminal program, use the pull down menu item transfer Send -> send files when dialog box prompts, choose Xmodem and the file in the directory then press send. (1). If the expander receives the file under the timeout limit (60s), the process starts. (2). If time out, please retry the step E again. 32 Netstor
36 CLI Command G. You can also cancel the program step by type q. H. If transfer OK, the transfered data is updated. Cold-start expander (Power cycle again) to take effect. Example: Update procedure, use Xmodem to transfer, refer to fdl command for detail operation. CLI> fdl { code mfgb } offset[enter] Use HyperTerminal or TeraTerm utility with Xmodem mode to transfer and update files. If transfer OK, the transfered data is updated. Cold-start expander (Power cycle again) to take effect. The following firmware and data are available in the following filename format. (1)FW file (CODE) : sas2xfwxxxx.fw (2)Data file (MFGB) : mfgdat6gyyyy.rom Update 6Gb/s SAS JBOD enclosure firmware: CLI> fdl code 0 Use HyperTerminal or TeraTerm utility with Xmodem mode to transfer sas2xfwxxxx.fw. If transfer OK, the transfered data is updated. Cold-start expander (Power cycle again) to take effect. Update SAS expander data file: CLI>fdl mfgb 0 Use HyperTerminal or TeraTerm utility with Xmodem mode to transfer mfgdat6gyyyy.rom. If transfer OK, the transfered data is updated. Cold-start expander (Power cycle again) to take effect. Netstor 33
37 CLI Command FAN Command The fan command defines the speed of the four fans within the 6Gb/s SAS JBOD enclosure. You are able to set the speed of fan on code between 1 and 7. Code 1 means the slowest speed, and code 7 stands for the highest speed of fan. It is suggested that the speed of fan to be set between codes 5 to 7 because as it is set under code 4, the system for the detection of fan speed becomes sensitive and it will get to beep easily. Syntax CLI> fan [ speed code speed code ] [Enter] The speed of the four fans will be defined by the speed code you entered. Example: CLI> fan 7 7 The speed of the four fans will be set to the highest. CLI> st Save the configuration to the system. Contacting Netstor Customer Service The Netstor website at has technical updates, and the most current product and support information. Please check our website for the latest updates and online support files for helpful information. If further assistance is needed, please contact us in one of the following ways: Skype: netstor_fae fae@netstor.com.tw Tel: Netstor
SAFETY PRECAUTIONS. Warnings
SAFETY PRECAUTIONS Please read this section carefully before proceeding. These precautions explain the correct and safe use of this device, thereby helping to prevent injury to you or others, and also
More informationUT_S Gbps SAS/SATA
UT_S2-2425 6Gbps SAS/SATA Expander JBOD SERIES Userʼs Manual Revision 1.0 For the most up-to-date version of user manual, please visit UTran s website at www.utran.com.tw Preface Change Notice The information
More informationRAID Machine 5000 Series
RAID Machine 5000 Series 12/16/24 Bays SAS JBOD Enclosure www.raidmachine.com USER Manual Version: 1.2 Issue Date: July, 2017 Copyright and Trademarks The information regarding products in this manual
More informationSAS JBOD Installation Reference Guide Revision 1.0
SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1
SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying
More informationFUSION 400. User s Guide. 4-Bay Serial ATA Hot-Swap Drive Enclosure. For Windows
FUSION 400 4-Bay Serial ATA Hot-Swap Drive Enclosure User s Guide For Windows Fusion 400 Specifications and Features Drive Tray (Slot 1) Drive Tray (Slot 2) Drive Tray (Slot 3) Drive Tray (Slot 4) Specifications
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1
SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2
SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts
More informationFUSION R400 RAID USB 3.0
FUSION R400 RAID USB 3.0 1U Rackmount 4-Drive Hardware RAID 5 SATA Storage System with USB 3.0 Interface User s Guide For Windows Contents 1 Fusion R400 RAID USB 3.0 Features 1 2 Drive Installation and
More informationFUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide
FUSION RX1600RAID Rackmount 16-Drive SATA Storage System with Internal SAS Expanders Drive Enclosure User s Guide Fusion RX1600RAID Enclosure Specs and Features SAS Cable Connection Indicators Mute Button
More informationFUSION RX1600RAID. Rackmount 16-Drive SATA Storage System with Internal SAS Expanders. Drive Enclosure User s Guide
FUSION RX1600RAID Rackmount 16-Drive SATA Storage System with Internal SAS Expanders Drive Enclosure User s Guide Fusion RX1600RAID Enclosure Specs and Features SAS Cable Connection Indicators Mute Button
More informationSAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0
SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking
More informationFUSION QR. User s Guide. 4-Drive Hardware RAID 5 SATA Storage System with Quad Interface. For Windows
FUSION QR 4-Drive Hardware RAID 5 SATA Storage System with Quad Interface User s Guide For Windows Contents 1 Fusion QR Features 1 2 Enclosure Setup; Access Drives and Mode Switch 2 Connect the Fusion
More informationFUSION R800RAID. 8-Bay Serial ATA Disk Array Storage System. Drive Enclosure User s Guide
FUSION R800RAID 8-Bay Serial ATA Disk Array Storage System Drive Enclosure User s Guide Fusion R800RAID Enclosure Specs and Features (Bay 1) Power LED (Bay 2) (Bay 3) (Bay 4) (Bay 1) (Bay 2) (Bay 3) (Bay
More information64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0
64 Bays SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Preface... 4 Before You Begin... 5 Safety Guidelines... 5 Controller Configurations... 5 Packaging, Shipment and Delivery... 5 Unpacking
More informationFUSION D800RAID. Drive Enclosure User s Guide. 8-Drive Serial ATA Disk Array Storage System. For Windows
FUSION D800RAID 8-Drive Serial ATA Disk Array Storage System Drive Enclosure User s Guide For Windows Fusion D800RAID Enclosure Specs and Features (Bay 1) (Bay 2) (Bay 3) (Bay 4) (Bay 5) (Bay 6) (Bay 7)
More informationFUSION D800P2. Drive Enclosure User s Guide. 8-Drive Serial ATA Disk Array Storage System with Dual Port Multipliers. For Windows
FUSION D800P2 8-Drive Serial ATA Disk Array Storage System with Dual Port Multipliers Drive Enclosure User s Guide For Windows Fusion D800P2 Enclosure Specs and Features (Bay 1) Specifications Compatibility
More informationTaurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1
Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.1 EN Table of Contents Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC
More informationTaurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2
Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.inxtron.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...
More informationRT5. User s Manual. Contents
RT5 User s Manual (revised 5/10/07) Contents 1. Features 3 1.1 System Architecture 3 1.1.1 Ultra ATA/133 & SATA 1.0 Host Interface 3 1.1.2 Ultra ATA/133 Drive Interface 3 1.2 RAID Subsystem Controller
More informationTaurus Mini Super-S LCM
Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives User Manual August 1, 2011 v1.0 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 System Requirements...
More informationTaurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2
Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives User Manual July 27, 2009 - v1.2 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III
More informationNA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual
NA381TB3 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion User Manual First edition, June. 2017 1. Overview 3 2. Package Checklist 3 3. Panel Layout 4 4. Hardware Configuration 5 5. Building
More informationFUSION R400Q 4-Bay Serial ATA Rackmount Drive Enclosure with Quad Interface
FUSION R400Q 4-Bay Serial ATA Rackmount Drive Enclosure with Quad Interface User s Guide For Windows Fusion R400Q Specifications and Features Drive Presence LED (Bay 1) Power LED Drive Presence LED (Bay
More informationHydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2
4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, 2009 - v1.2 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM
More informationeraid Multi interface RAID system Manual
eraid Multi interface RAID system Manual Version 1.0 Features The eraid system is designed in a space saving portable tower TBD x TBD x TBD for easy implement RAID system into workstations or servers.
More informationXL-RAID-SATA-USB Data Backup System. User s Guide
XL-RAID-SATA-USB Data Backup System User s Guide Forewords About this manual Thank you for using products from XtendLan. This manual will introduce the XL-RAID-SATA-USB product. Before using XtendLan XL-RAID-SATA-USB
More informationYour Data Security Guardian. SafeTANK GR5630-WSB3+ User Manual. v.1.0 (Oct, 2012)
SafeTANK GR5630-WSB3+ User Manual v..0 (Oct, 202) Table of Contents Chapter. Package Contents and Product Views Chapter 2. Environmental Requirements Chapter 3. Hardware Requirements and Precautions Chapter
More informationUser s Guide. for Echo Express and Echo Express Pro Thunderbolt Expansion Chassis for PCIe Cards
User s Guide for Echo Express and Echo Express Pro Thunderbolt Expansion Chassis for PCIe Cards Contents 1 Introduction... 1 2 Echo Express Chassis Description Description... 2 3 PCIe Card Installation
More informationFUSION F2. User s Guide. Portable 2-Drive RAID SATA Storage System. For Windows
FUSION F2 Portable 2-Drive RAID SATA Storage System User s Guide For Windows Fusion F2 Specifications and Features Drive Power/Activity LED Drive Power/Activity LED Figure 1 esata Connector Figure 2 Power
More informationUser s Guide. for Echo Express SE II Thunderbolt 2-to-PCI Express Card Expansion Chassis. For Windows
User s Guide for Echo Express SE II Thunderbolt 2-to-PCI Express Card Expansion Chassis For Windows Contents 1 Introduction, System Requirements 1 2 Echo Express SE II Description 2 Echo Express SE II
More informationNA380A-G3. 4U 24-Bay External PCIe 8 JBOD Storage with PCIe Slot Expansion. User Manual
NA380A-G3 4U 24-Bay External PCIe 8 JBOD Storage with PCIe Slot Expansion User Manual First edition, Apr. 2018 1. Unpack the NA380A-G3 3 2. Panel Layout 3 3. PCIe Expansion Layout 5 4. Build Up Procedure
More informationUser s Guide. for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems
User s Guide for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems Important GPU Card Compatibility and Installation Information For users installing a GPU
More informationUser s Guide. for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems. For Windows
User s Guide for egfx Breakaway Box and egfx Breakaway Box 550 Thunderbolt 3 to egpu PCIe Card Expansion Systems For Windows Contents 1 Introduction, Compatibility Information, and Setup Overview 1 Introduction
More informationTurbo PCI Express. PCI Express adapter for desktop PC. PCIe 4 to PCIe 4 data cable, 1.5 meter. Turbo ExpressCard. ExpressCard 34 adapter for laptop
1. Overview TurboBox is an external device for PCI Express slot expansion. Both desktop PCs and laptops can be connected with the TurboBox. This quick installation guide helps you with the setting up of
More informationInstalling and Managing the Switch
CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4
More informationMD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0
4-Bay Rack Mount Chassis User Manual February 6, 2009 - v1.0 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM esata equipped
More informationUser s Guide. Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server. Quick Start Guide Video Available Online!
User s Guide Mobile Rack Device Mounting Kit for Echo Express III-R and xmac Pro Server Quick Start Guide Video Available Online! Visit http://www.sonnettech.com/product/ mobilerackkit.html Click the Video
More informationJanusRAID SA-6692J Hardware User Manual
JanusRAID SA-6692J Hardware User Manual 42-30000-5067 SATA II JBOD enclosure Version 1.1 SA-6692J SATA II JBOD enclosure Hardware User Manual Table of Contents Preface... i Chapter 1 System Requirements
More informationAtlas S8+ Product Manual. Version Promise Technology, Inc. All Rights Reserved.
Atlas S8+ Product Manual Version 1.0 2018 Promise Technology, Inc. All Rights Reserved. Promise Technology Atlas S8+ Copyright 2018 PROMISE Technology, Inc. All Rights Reserved. Important data protection
More informationULTRATRAK SERIES RM4000, SX4000, RM8000, SX8000, RM15000 USER MANUAL. Version 2.2
ULTRATRAK SERIES RM4000, SX4000, RM8000, SX8000, RM15000 USER MANUAL Version 2.2 UltraTrak Series User Manual Copyright 2003, Promise Technology, Inc. All Rights Reserved. Copyright by Promise Technology,
More informationDNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.
DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3
More informationFUSION R400QR5. User s Guide. 4-Bay Serial ATA Rackmount Disk Enclosure with Quad Interface. For Windows
FUSION R400QR5 4-Bay Serial ATA Rackmount Disk Enclosure with Quad Interface User s Guide For Windows Fusion R400QR5 Specifications and Features Drive Presence LED (Bay 1) Power LED Drive Presence LED
More informationUser s Guide. for xmac mini Server 2H Thunderbolt -to-pcie Expansion System and 1U Rack Enclosure for Mac mini With Thunderbolt Port
User s Guide for xmac mini Server 2H Thunderbolt -to-pcie Expansion System and 1U Rack Enclosure for Mac mini With Thunderbolt Port Contents 1 Introduction and Package Contents... 1 Introduction Package
More informationFirst Edition, July 2011
First Edition, July 2011 Copyright Netstor Technology Co., Ltd. All rights reserved Table of contents 1. Introduction P1 2. Configuration via GUI 2.1 Starting the RAID Manager P1 2.1.1 For Windows operating
More informationXL-RAID-213SA User Manual
XL-RAID-213SA User Manual Introduction English Thank you for purchasing our products. This manual will introduce the XL-RAID-213SA Series. Before using your XL-RAID-213SA, please read this manual thoroughly.
More informationOWC Mercury Rack Pro Assembly Manual & User Guide
Assembly Manual & User Guide Table of Contents 1. INTRODUCTION... 1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Hard Drives 1.2 PACKAGE CONTENTS 1.3 ABOUT
More informationHighPoint NA381TB3. 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion. User Manual
HighPoint NA381TB3 4U 24 bay ( 3.5" / 2.5" ) Thunderbolt 3 Storage and PCIe Expansion User Manual First edition, June. 2017 1. Overview 3 2. Package Checklist 3 3. Panel Layout 4 4. Hardware Configuration
More informationNA265A. External PCIe 3.0 to GPU Rackmount Enclosure. User Manual
NA265A External PCIe 3.0 to GPU Rackmount Enclosure User Manual First edition, Dec. 2017 1. Unpack the NA265A 3 2. Expansion Chassis Description 3 2.1 Panel Layout 2.2 Slot Board Layout 2.3 Switches Function
More informationDNS-2608 Enterprise JBOD Enclosure User Manual
DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved. www.dataonstorage.com 1 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON
More informationUser Guide & Owners Manual
User Guide & Owners Manual Table of Contents 1 INTRODUCTION 1.1 SYSTEM REQUIREMENTS 1.1.1 Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Hard Drives 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS MANUAL 1.4
More informationA12S2-PS. Quick Start Guide. August, 2012 V.1.4
A12S2-PS August, 2012 V.1.4 Revision Sheet Release No. Date Revision Description V.1.1 2012/4/10 Initial creation. V.1.2 2012/8/22 Piuture correct on P.3, P.4, P.7, P.11, Modify some wording on P.5, P.10,
More informationUser s Guide. for Echo Express SEL 10GbE. 10 Gigabit Ethernet Thunderbolt 2 Adapter
User s Guide for Echo Express SEL 10GbE 10 Gigabit Ethernet Thunderbolt 2 Adapter Contents 1 Introduction, System Requirements, Driver Information 1 2 Echo Express SEL 10GbE Description 2 Echo Express
More information3. Install Graphics/PCIe Cards in NA255A 8
NA255A Performance Desktop PCIe 3.0 x16 (128Gbps) upstream port PCI-Express expansion enclosure particularly design for GPU cards (Available up to 4* double width PCIe Gen3 slots) User Manual First edition,
More informationMERCURY RACK PRO. Assembly Manual & User Guide
MERCURY RACK PRO Assembly Manual & User Guide INTRODUCTION 1.1 Minimum System Requirements... 1 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Hard Drives 1.2 Package Contents... 1
More informationHigh Density RocketRAID Rocket EJ240 Device Board Data RAID Installation Guide
High Density RocketRAID 2711 + Rocket EJ240 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini-
More informationInstalling the Cisco Unified Videoconferencing 3545 MCU
CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)
More information3U 16-bay PCI-Express Rackmount JBOD Chassis. Installation Guide
3U 16-bay PCI-Express Rackmount JBOD Chassis Installation Guide Package Checklist Before installing this unit, verify that package contains the following items: Enclosure x 1 HDD Tray x 16 (Installed in
More informationHigh Density RocketRAID EJ6172 Device Board Data RAID Installation Guide
High Density RocketRAID 2711 + EJ6172 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini- SAS port.
More informationUsers Manual STP-103II. Thermal Printer Rev
Users Manual STP-103II Thermal Printer Rev. 1.00 http://www.bixolon.com Safety Precautions The instructions shown below must be followed to prevent possible danger or damage by using the product incorrectly.
More informationBrand. E42 / E82 DVR System User Manual
Brand E42 / E82 DVR System User Manual 1 Safety precautions Before using the product, please ensure that you read the safety precautions described below. Always ensure that the product is used correctly.
More informationUser s Guide. for Echo Express III-R Rackmount Thunderbolt -to-pcie Card Expansion Chassis
User s Guide for Echo Express III-R Rackmount Thunderbolt -to-pcie Card Expansion Chassis Contents 1 Introduction... 1 2 Echo Express III-R Description... 2 3 PCIe Card Installation and Chassis Setup
More informationUser s guide for T5_R5 esuf
User s guide for T5_R5 esuf Overview Introduction T5_R5-ESUF is One to Five SATA Port Multiplier hardware RAID Controller with LCD Module. It is designed to provide USB2.0/FireWire400/800 and esata ports
More informationNAS System. User s Manual. Revision 1.0
User s Manual Revision 1.0 Before You Begin efore going through with this manual, you should read and focus on the following safety guidelines. Information about the NAS system s packaging and delivery
More informationSSD Bay U.2 NVMe RAID Enclosure. User Guide V1.00
SSD6540 4-Bay U.2 NVMe RAID Enclosure User Guide V1.00 1 Kit Contents 1x 4-Bay Tower Enclosure 1x PCIe 3.0 x16 RAID Controller 4x Drive Trays 2x HD mini-sas cable (1 meter) 1x UL Power Cord 16x 2.5 SSD
More informationiosafe SERVER 5 Quick Start Guide
iosafe SERVER 5 Quick Start Guide 910-11782-00 Rev02 QUICKSTART GUIDE, SERVER 5 Table of Contents Chapter 1: Before You Start Package Contents... 3 iosafe at a Glance... 4 Safety Instructions... 5 Chapter
More informationDRIVE DOCK. User Guide
DRIVE DOCK User Guide CONTENTS INTRODUCTION 1.1 Minimum System Requirements...1 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives 1.2 Package Contents...1 1.3 About This Manual...1
More informationiosafe BDR515 Hardware Guide
iosafe BDR515 Hardware Guide 910-11762-00 Rev03 HARDWARE GUIDE, BDR515 Table of Contents Chapter 1: Before You Start Package Contents... 3 iosafe at a Glance... 4 Safety Instructions... 5 Chapter 2: Hardware
More informationXL-NAS-400SA. User s Guide
XL-NAS-400SA User s Guide Table of Contents Chapter 1 Hardware devices 1.1 1.2 1.3 Accessories and XL-NAS-400SA at a glance LCD message and light indicators Hardware installation Chapter 2 Initial setup
More informationTHUNDERBAY 4 MINI. Assembly Manual & User Guide
THUNDERBAY 4 MINI Assembly Manual & User Guide CONTENTS INTRODUCTION 1.1 Minimum System Requirements...1 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives 1.2 Package Contents...1
More informationAlnico Gen2 Series, 12Gbps SAS to 6Gbps SAS/SATA JBOD Subsystems Installation Guide. Version 1.0
Alnico Gen2 Series, 12Gbps SAS to 6Gbps SAS/SATA JBOD Subsystems Installation Guide Version 1.0 Apr./10/2014 Copyright 2014 This guide and any accompanying software and firmware are copyrighted. No parts
More informationDRIVE DOCK. User Guide
DRIVE DOCK User Guide CONTENTS INTRODUCTION 1.1 Minimum System Requirements...1 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives 1.2 Package Contents...1 1.3 About This Manual...1
More informationNT2 U3. 2-Bay RAID Storage Enclosure. User Manual May 18, 2010 v1.1
2-Bay RAID Storage Enclosure User Manual May 18, 2010 v1.1 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM Windows Vista, Windows
More informationMercury Elite Pro mini ASSEMBLY MANUAL & USER GUIDE
Mercury Elite Pro mini ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Mac Requirements 1.1.2 PC Requirements 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS
More informationOWC Mercury On-The-Go Pro USER GUIDE
OWC Mercury On-The-Go Pro USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.2 PACKAGE CONTENTS 1.3 ABOUT THIS MANUAL
More informationRAIDTech USER S MANUAL. Revised October 3, Features
RAIDTech USER S MANUAL Revised October 3, 2006 Features Simple, hardware-based RAID (levels 0 or 1) On-the-fly data protection: RAID 1 makes backing up as painless as possible. The data is mirrored in
More informationTRADEMARKS All brand and product names are trademarks or registered trademarks of their respective companies. NOTE The information in this manual is
TRADEMARKS All brand and product names are trademarks or registered trademarks of their respective companies. NOTE The information in this manual is subject to change without notice. Safety Information
More informationCHENBRO. User s Manual port 6Gb/s SAS Expander Backplane 80H A0. Version A0
- 1 - CHENBRO 3.5 24-port 6Gb/s SAS Expander Backplane 80H10341801A0 Version A0 May / 05 / 2011 - 2 - Copyright Copyright 2011 CHENBRO Micom Co., Ltd.. All rights reserved. Unless otherwise indicated,
More informationUser s Guide. for Echo Express SEL - Thunderbolt 3 Edition Thunderbolt 3-to-PCIe Card Expansion Chassis. For Windows
User s Guide for Echo Express SEL - Thunderbolt 3 Edition Thunderbolt 3-to-PCIe Card Expansion Chassis For Windows Contents 1 Introduction, System Requirements, and Setup Overview 1 Introduction Mac Compatibility
More informationRocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. User s Guide v1.0
RocketRAID 2840A SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller User s Guide v1.0 1 Table of Contents 1. HighPoint RocketRAID 2840A Overview... 3 2. Board Layout & Hardware Installation... 4 3. Using the
More informationInTANK Series ir2620-2s-s2 / SR2611-2S-S2R User Manual
InTANK Series ir2620-2s-s2 / SR26-2S-S2R User Manual ir2620-2s-s2 SR26-2S-S2R v.2.2 (Jun, 20) Index Chapter Check Package Contents and Accessories... Chapter 2 Hardware Introduction... Chapter Precaution
More informationG-SPEED Product Guide
G-SPEED Product Guide G-Technology Inc. Tel: (310) 449-4599 Fax: (310) 449-4670 support@g-technology.com TABLE OF CONTENTS 1. INTRODUCTION 2. SAFETY PRECAUTIONS 3. SYSTEM REQUIREMENTS 4. WHAT S IN THE
More informationTABLE OF CONTENTS INTRODUCTION...1 DEVICE SETUP...4 SUPPORT RESOURCES...9
TABLE OF CONTENTS INTRODUCTION...1 1.1 Minimum System Requirements 1.2 Package Contents 1.3 About This Manual 1.4 Rear View 1.4.1 Rear Features 1.5 Usage Notes DEVICE SETUP...4 2.1 Quick Start 2.2 Assembly
More informationACT-ARS3020/22 Disk Array Series products
ACT-ARS3020/22 Disk Array Series products Quick Installation Guide VER:1.0 ACE-POWER COMPUTER TECHNOLOGY CORP 17F.-3, No.116, Zhengxin St., Zuoying Dist., Kaohsiung City 813, Taiwan (R.O.C.) TEL:07-5575193
More informationOWC Mercury Elite Pro Dual mini ASSEMBLY MANUAL & USER GUIDE
OWC Mercury Elite Pro Dual mini ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS 1. INTRODUCTION... 1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives
More informationPU-160ETH. Ethernet and USB to HDMI Converter. Operation Manual PU-160ETH
PU-160ETH Ethernet and USB to HDMI Converter Operation Manual PU-160ETH Trademark Acknowledgments All products or service names mentioned in this document may be trademarks of the companies with which
More informationAlnico Gen2 Series, 12Gbps SAS to 12Gbps SAS JBOD Subsystems Installation Guide. Version 1.1
Alnico Gen2 Series, 12Gbps SAS to 12Gbps SAS JBOD Subsystems Installation Guide Version 1.1 Nov./03/2015 Copyright 2015 This guide and any accompanying software and firmware are copyrighted. No parts of
More informationDell EMC PowerVault MD3460 Storage Arrays
Dell EMC PowerVault MD3460 Storage Arrays Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you
More informationSivy SA-4327S Hardware User Manual
Sivy SA-4327S Hardware User Manual esata to Serial ATA II Disk Array System Version 1.0 SA-4327S esata to Serial ATA II Disk Array System Hardware User Manual Table of Contents Preface... i Chapter 1
More information24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed. Metro Ethernet Switch MGSW-28240F. Quick Installation Guide
24-Port 100/1000X SFP + 4-Port 10G SFP+ Managed Metro Ethernet Switch MGSW-28240F Quick Installation Guide Table of Contents 1. Package Contents... 3 2. Requirements... 4 3. Wiring DC Power Inputs... 5
More informationQuick Start Turning on the Tablet PC for the First Time
User s Manual DL46 Getting Started Congratulations on your purchase of a Tablet PC. The Tablet PC is a fully functional PC with built-in LAN, and wireless connectivity. With your Tablet PC you will be
More informationMercury Helios ASSEMBLY MANUAL & USER GUIDE
Mercury Helios ASSEMBLY MANUAL & USER GUIDE TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported PCIe Cards NOTE: Boot Camp
More informationTHUNDERBAY 4. Assembly Manual & User Guide
THUNDERBAY 4 Assembly Manual & User Guide TABLE OF CONTENTS INTRODUCTION...1 1.1 MINIMUM SYSTEM REQUIREMENTS 1.1.1 Apple Mac Requirements 1.1.2 PC Requirements 1.1.3 Supported Drives: up to four 3.5 SATA
More informationVTPC190V / VS / VDC / VSDC
Solutions for Demanding Applications VARTECH S Y S T E M S I N C. 19.0 Enclosed VESA Mount PC Model VTPC190V / VS / VDC / VSDC User s Guide Read these instructions completely before attempting to operate
More informationSAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE
+ SAS933E REV 1.12 A BAR ODE SAS-933E The SAS-933E2/E1 Storage Backplane USER'S GUIDE Rev. 1.0 SAS-933E User s Guide Table of ontents Safety Information and Technical Specifications...1-3 1. Safety Guidelines...
More information8 Button RS232/IR. Control Panel. MuxLab Inc A / SE A
8 Button RS232/IR Control Panel 500816 MuxLab Inc. 2016 94-000833-A / SE-000833-A SAFETY PRECAUTIONS To insure the best use from the product, please read all instructions carefully before using the device.
More informationGraniteRack 3U Chassis Digital Storage System
GraniteRack 3U Chassis Digital Storage System User Manual model no. OE-GRANITE3U 28080AB Please carefully read these instructions before using this product. Save this manual for future use. Copyright No
More informationVTrak J5000 Series. Product Manual. 12G SAS JBOD enclosure. Version PROMISE Technology, Inc. All Rights Reserved.
VTrak J5000 Series 12G SAS JBOD enclosure Product Manual Version 1.2 2017 PROMISE Technology, Inc. All Rights Reserved. VTrak J5000 Series Promise Technology Warning This is a Class A product. In a domestic
More informationRocsecure NE52 NAS System
Rocsecure NE52 NAS System Revision 1.0 Table of Contents Preface... 3 Before You Begin... 4 Safety Guidelines... 4 Packaging, Shipment and Delivery... 4 Chapter 1 Introduction... 5 1.1 Key Features...
More informationSVMi-8E/SVMi-16E Installation
SVMi-8E/SVMi-16E Installation Table of Contents 1 Installing the SVMi-8E/SVMi-16E in the Phone System 3 Installing the SVMi-8E in an idcs 100 3 General 3 System Resources 3 idcs 100 Hardware Compatibility
More information