Product Overview SIPLUS

Size: px
Start display at page:

Download "Product Overview SIPLUS"

Transcription

1 AG 1 AG 1 Overview August 1 Products for specific requirements AG Industry Sector Control Components and Systems Engineering Postfach FÜRTH GERMANY Subject to change out prior ice Order.: 6ZB511-AX-BA MP.R.XT... / Dispo 71 PT 1. ROT EN Printed in Germany AG 1 The information provided in this overview contains descriptions or characteristics of performance which in case of actual use do always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change out ice. All product designations may be trademarks or product names of AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. siemens.com/siplus

2 DRAFT August 7, 1 AG 1 extreme LOGO! S7- S7-1 S7- S7-F S7-/H PCS7 Bundle ET M ET M F ET S ET S F Micro Touch Operator Industrial Multi Basic s Processors NET SINAUT AS-Interface Supply SIMOCODE power smart modular UPS upmiter / ST / ST PC ST / ST PC ST / ST PC ST / ST PC ST / ST PC KT 1.1 KT 1.1 KT 1.1 KT 1.1 Modular logic for control tasks in the er performance ; maximum perfor- controllers for discrete for the to midmance capability and stand-alone auto- performance s mation s for the to mid-performance s for performance s Flexible, scalable automation IP degree IP degree in S7- for displaying Touch control machines and plants analog touch screen and single platform; available touch screen panels basic for all SIMATIC Profibus/Profinet : Industrial switches and Industrial media MD dedicated for recording and transmitting Specification.1 or Specification. for automation s in the er performance ; wide- input for - V DC; small, ful standard power, and high for demanding s, compact DC UPS rechargeable lead-gel upmiter and power reliable on min [ C ] (= start temp.) / - / / / / - / - -1/ / -1 / -1/ / / / - / / / / +7 / +7 / +7 / +7 +5/ / / +7 / +7 / / +7 / Operating temperature Pollutant concentration in accordance EN Suitable for industrial atmospheres in accordance EN Class C for chemically active substances such as SO, HS, Cl, HCl, incl. salt mist, EN Class B for biologically active substances such as mold and fungal spores, and EN Class S for mechanically active substances, including sand and dust / / / Salt mist in accordance EN Country-specific approvals: CE (Europe), C-Tick (Australia/New Zealand), UL (USA/Canada), KC (South Korea), Gost R (Russian Federation); Hazardous areas: FM, ATEX, ULhaz; Marine classification societies: ABS, BV, DNV, GL, LRS; Railroad applications: EN 5155 (rolling stock), EN 511- (rail automation); Special environmental requirements: EN 671 (corrosive gas) The actually valid operating conditions and approvals depend on the HCS CMS ECC Multi-Vendor Systems HCS7I HCS7I ET S S7- S7- based on S7-/ H/F The HCS industrial heating control s permit extremely precise and efficient control of ohmic loads such as infrared heaters or : relay outputs 5 A each DM: 6 channels.5 A each IM151- / IM151-F 1C 1 KB / / n-retain / 1 KB 1 KB / 15 / 15F 17 / 17F 19 / 19F KB / 51 KB 1 KB / 1 56 KB KB / 56 KB 1 KB / KB 76 KB / 1 KB 1 KB / 1 6 KB 1 KB 1-1 KB MB 7 KB Possible via current or current/voltage detection (evaluation in ) detecting faults during parallel of.5 MB MB.5 MB MB (non-retain) ) 7 KB) 1 KB) 9% 9% 9% IEC (connection devices) IEC ( networks TCP/IP) 5% 1 / IEC ) / ) 96 KB).5 MB) 7% 5% 5% via CP 5 5 / 5 station control technology; robustness in the data link layer (hamming distance, simple structure of the user layer; asynchronous protocol for serial transmission (V./V., V.11) used for asynchronous connections (V./V., RS or RS5); can be expanded to include proprietary, manufacturer-specific functions SO_POSTER EN_Kristfeld_1 DRUCK.indd 1 1 (per central interface) Dependent on the used Dependent on the controller used Load t because digital outputs are overload LA7I HP: channel fuses 1 A V in Y mode;. kw ( V in Y mode); kw ( V in Δ mode).65 kw ( V) ( V) LA7I HP: output channels;. kw ( V) program AT CMS1 CMS CMS CM- CM-1 LA7I: fuses A LA7I HP: fuses A V AC +/- 15% input voltage Operating temperature - C to +55 C 1 kg door weight kg door weight power adjustment using motor facilitates % weight reduction 1 kg 1 kg With ECC, the s for the charging infrastructure, permit standard-compliant and reliable charging of electric vehicles. matter whether you are (IE C 6151) for for (1/1 Mbit/s) Integrated or 11/ V AC 1,,, A; 1/ A switchable Bearing monitoring: DKW, K(t) according to VDI, vibration monitoring: RMS DIN ISO1- The CMS are used for monitoring mechanical components permanently. 1 kg kg Q (H bridge) unit snapshot of the FFT,, long-term trend recording RS5 V max.5 m/s max. sec (typical) RS5 (In) V max.7 m/s max.9 sec ( kg) (typical). sec (1 kg) (typical).6 sec (1 kg) (typical) Can be set between 6 A... A IEC/EN Part 1 and Part (conductive charging s for electric vehicles), charging mode, CE according to IEC 611, C-Tick 1/AC CM- CMS X-Tools software 1,.1 Hz to khz Hz to khz khz khz IEPE vibration, (digital) 6 temperature 1 Hz to 1 khz 1/AC HMI KTP 6 Public charging implemented CM- () ECC CM- ECC CM- HCSI ECC ECC1 S7-/H/F Bundle - Bundle - Bundle SIMATIC ET S :1:

3 DRAFT August 7, 1 AG 1 extreme LOGO! S7- S7-1 S7- S7-F S7-/H PCS7 Bundle ET M ET M F ET S ET S F Micro Touch Operator Industrial Multi Basic s Processors NET SINAUT AS-Interface Supply SIMOCODE power smart modular UPS upmiter / ST / ST PC ST / ST PC ST / ST PC ST / ST PC ST / ST PC KT 1.1 KT 1.1 KT 1.1 KT 1.1 Modular logic for control tasks in the er performance ; maximum perfor- controllers for discrete for the to midmance capability and stand-alone auto- performance s mation s for the to mid-performance s for performance s Flexible, scalable automation IP degree IP degree in S7- for displaying Touch control machines and plants analog touch screen and single platform; available touch screen panels basic for all SIMATIC Profibus/Profinet : Industrial switches and Industrial media MD dedicated for recording and transmitting Specification.1 or Specification. for automation s in the er performance ; wide- input for - V DC; small, ful standard power, and high for demanding s, compact DC UPS rechargeable lead-gel upmiter and power reliable on min [ C ] (= start temp.) / - / / / / - / - -1/ / -1 / -1/ / / / - / / / / +7 / +7 / +7 / +7 +5/ / / +7 / +7 / / +7 / Operating temperature Pollutant concentration in accordance EN Suitable for industrial atmospheres in accordance EN Class C for chemically active substances such as SO, HS, Cl, HCl, incl. salt mist, EN Class B for biologically active substances such as mold and fungal spores, and EN Class S for mechanically active substances, including sand and dust / / / Salt mist in accordance EN Country-specific approvals: CE (Europe), C-Tick (Australia/New Zealand), UL (USA/Canada), KC (South Korea), Gost R (Russian Federation); Hazardous areas: FM, ATEX, ULhaz; Marine classification societies: ABS, BV, DNV, GL, LRS; Railroad applications: EN 5155 (rolling stock), EN 511- (rail automation); Special environmental requirements: EN 671 (corrosive gas) The actually valid operating conditions and approvals depend on the HCS CMS ECC Multi-Vendor Systems HCS7I HCS7I ET S S7- S7- based on S7-/ H/F The HCS industrial heating control s permit extremely precise and efficient control of ohmic loads such as infrared heaters or : relay outputs 5 A each DM: 6 channels.5 A each IM151- / IM151-F 1C 1 KB / / n-retain / 1 KB 1 KB / 15 / 15F 17 / 17F 19 / 19F KB / 51 KB 1 KB / 1 56 KB KB / 56 KB 1 KB / KB 76 KB / 1 KB 1 KB / 1 6 KB 1 KB 1-1 KB MB 7 KB Possible via current or current/voltage detection (evaluation in ) detecting faults during parallel of.5 MB MB.5 MB MB (non-retain) ) 7 KB) 1 KB) 9% 9% 9% IEC (connection devices) IEC ( networks TCP/IP) 5% 1 / IEC ) / ) 96 KB).5 MB) 7% 5% 5% via CP 5 5 / 5 station control technology; robustness in the data link layer (hamming distance, simple structure of the user layer; asynchronous protocol for serial transmission (V./V., V.11) used for asynchronous connections (V./V., RS or RS5); can be expanded to include proprietary, manufacturer-specific functions SO_POSTER EN_Kristfeld_1 DRUCK.indd 1 1 (per central interface) Dependent on the used Dependent on the controller used Load t because digital outputs are overload LA7I HP: channel fuses 1 A V in Y mode;. kw ( V in Y mode); kw ( V in Δ mode).65 kw ( V) ( V) LA7I HP: output channels;. kw ( V) program AT CMS1 CMS CMS CM- CM-1 LA7I: fuses A LA7I HP: fuses A V AC +/- 15% input voltage Operating temperature - C to +55 C 1 kg door weight kg door weight power adjustment using motor facilitates % weight reduction 1 kg 1 kg With ECC, the s for the charging infrastructure, permit standard-compliant and reliable charging of electric vehicles. matter whether you are (IE C 6151) for for (1/1 Mbit/s) Integrated or 11/ V AC 1,,, A; 1/ A switchable Bearing monitoring: DKW, K(t) according to VDI, vibration monitoring: RMS DIN ISO1- The CMS are used for monitoring mechanical components permanently. 1 kg kg Q (H bridge) unit snapshot of the FFT,, long-term trend recording RS5 V max.5 m/s max. sec (typical) RS5 (In) V max.7 m/s max.9 sec ( kg) (typical). sec (1 kg) (typical).6 sec (1 kg) (typical) Can be set between 6 A... A IEC/EN Part 1 and Part (conductive charging s for electric vehicles), charging mode, CE according to IEC 611, C-Tick 1/AC CM- CMS X-Tools software 1,.1 Hz to khz Hz to khz khz khz IEPE vibration, (digital) 6 temperature 1 Hz to 1 khz 1/AC HMI KTP 6 Public charging implemented CM- () ECC CM- ECC CM- HCSI ECC ECC1 S7-/H/F Bundle - Bundle - Bundle SIMATIC ET S :1:

4 DRAFT August 7, 1 extreme LOGO! S7- S7-1 S7- S7-F S7-/H PCS7 Bundle ET M ET M F ET S ET S F Micro Touch Operator Industrial Multi Basic s Processors NET SINAUT AS-Interface Supply SIMOCODE power smart modular UPS upmiter / ST / ST PC ST / ST PC ST / ST PC ST / ST PC ST / ST PC KT 1.1 KT 1.1 KT 1.1 KT 1.1 Modular logic for control tasks in the er performance ; maximum perfor- controllers for discrete for the to midmance capability and stand-alone auto- performance s mation s for the to mid-performance s for performance s Flexible, scalable automation IP degree IP degree in S7- for displaying Touch control machines and plants analog touch screen and single platform; available touch screen panels basic for all SIMATIC Profibus/Profinet : Industrial switches and Industrial media MD dedicated for recording and transmitting Specification.1 or Specification. for automation s in the er performance ; wide- input for - V DC; small, ful standard power, and high for demanding s, compact DC UPS rechargeable lead-gel upmiter and power reliable on min [ C ] (= start temp.) / - / / / / - / - -1/ / -1 / -1/ / / / - / / / / +7 / +7 / +7 / +7 +5/ / / +7 / +7 / / +7 / Operating temperature Pollutant concentration in accordance EN Suitable for industrial atmospheres in accordance EN Class C for chemically active substances such as SO, HS, Cl, HCl, incl. salt mist, EN Class B for biologically active substances such as mold and fungal spores, and EN Class S for mechanically active substances, including sand and dust / / / Salt mist in accordance EN Country-specific approvals: CE (Europe), C-Tick (Australia/New Zealand), UL (USA/Canada), KC (South Korea), Gost R (Russian Federation); Hazardous areas: FM, ATEX, ULhaz; Marine classification societies: ABS, BV, DNV, GL, LRS; Railroad applications: EN 5155 (rolling stock), EN 511- (rail automation); Special environmental requirements: EN 671 (corrosive gas) The actually valid operating conditions and approvals depend on the Multi-Vendor Systems CMS ECC HCSI HCS7I HCS7I ET S S7- S7- based on S7-/ H/F The HCS industrial heating control s permit extremely precise and efficient control of ohmic loads such as infrared heaters or : relay outputs 5 A each DM: 6 channels.5 A each IM151- / IM151-F 1C 1 KB / / n-retain / 1 KB 1 KB / 15 / 15F 17 / 17F 19 / 19F KB / 51 KB 1 KB / 1 56 KB KB / 56 KB 1 KB / KB 76 KB / 1 KB 1 KB / 1 6 KB 1 KB 1-1 KB MB 7 KB Possible via current or current/voltage detection (evaluation in ) detecting faults during parallel of.5 MB MB.5 MB MB (non-retain) ) 7 KB) 1 KB) 9% 9% 9% IEC (connection devices) IEC ( networks TCP/IP) 5% 1 / IEC ) / ) 96 KB).5 MB) 7% 5% 5% via CP 5 5 / 5 station control technology; robustness in the data link layer (hamming distance, simple structure of the user layer; asynchronous protocol for serial transmission (V./V., V.11) used for asynchronous connections (V./V., RS or RS5); can be expanded to include proprietary, manufacturer-specific functions SO_POSTER EN_Kristfeld_1 DRUCK.indd 1 1 (per central interface) Dependent on the used Dependent on the controller used Load t because digital outputs are overload LA7I HP: channel fuses 1 A V in Y mode;. kw ( V in Y mode); kw ( V in Δ mode).65 kw ( V) ( V) LA7I HP: output channels;. kw ( V) program AT CMS1 CMS CMS CM- CM-1 ECC ECC1 S7-/H/F Bundle - Bundle - LA7I: fuses A LA7I HP: fuses A V AC +/- 15% input voltage Operating temperature - C to +55 C 1 kg door weight kg door weight power adjustment using motor facilitates % weight reduction 1 kg 1 kg With ECC, the s for the charging infrastructure, permit standard-compliant and reliable charging of electric vehicles. matter whether you are (IE C 6151) for for (1/1 Mbit/s) Integrated or 11/ V AC 1,,, A; 1/ A switchable Bearing monitoring: DKW, K(t) according to VDI, vibration monitoring: RMS DIN ISO1- snapshot of the FFT,, long-term trend recording RS5 V max.5 m/s max. sec (typical) RS5 (In) V max.7 m/s max.9 sec ( kg) (typical). sec (1 kg) (typical).6 sec (1 kg) (typical) Can be set between 6 A... A IEC/EN Part 1 and Part (conductive charging s for electric vehicles), charging mode, CE according to IEC 611, C-Tick 1/AC CM- The CMS are used for monitoring mechanical components permanently. 1 kg kg Q (H bridge) unit CMS X-Tools software 1,.1 Hz to khz Hz to khz khz khz IEPE vibration, (digital) 6 temperature 1 Hz to 1 khz 1/AC HMI KTP 6 Bundle SIMATIC ET S HCS Public charging implemented CM- () ECC CM- ECC CM- AG :1:

5 DRAFT August 7, 1 extreme LOGO! S7- S7-1 S7- S7-F S7-/H PCS7 Bundle ET M ET M F ET S ET S F Micro Touch Operator Industrial Multi Basic s Processors NET SINAUT AS-Interface Supply SIMOCODE power smart modular UPS upmiter / ST / ST PC ST / ST PC ST / ST PC ST / ST PC ST / ST PC KT 1.1 KT 1.1 KT 1.1 KT 1.1 Modular logic for control tasks in the er performance ; maximum perfor- controllers for discrete for the to midmance capability and stand-alone auto- performance s mation s for the to mid-performance s for performance s Flexible, scalable automation IP degree IP degree in S7- for displaying Touch control machines and plants analog touch screen and single platform; available touch screen panels basic for all SIMATIC Profibus/Profinet : Industrial switches and Industrial media MD dedicated for recording and transmitting Specification.1 or Specification. for automation s in the er performance ; wide- input for - V DC; small, ful standard power, and high for demanding s, compact DC UPS rechargeable lead-gel upmiter and power reliable on min [ C ] (= start temp.) / - / / / / - / - -1/ / -1 / -1/ / / / - / / / / +7 / +7 / +7 / +7 +5/ / / +7 / +7 / / +7 / Operating temperature Pollutant concentration in accordance EN Suitable for industrial atmospheres in accordance EN Class C for chemically active substances such as SO, HS, Cl, HCl, incl. salt mist, EN Class B for biologically active substances such as mold and fungal spores, and EN Class S for mechanically active substances, including sand and dust / / / Salt mist in accordance EN Country-specific approvals: CE (Europe), C-Tick (Australia/New Zealand), UL (USA/Canada), KC (South Korea), Gost R (Russian Federation); Hazardous areas: FM, ATEX, ULhaz; Marine classification societies: ABS, BV, DNV, GL, LRS; Railroad applications: EN 5155 (rolling stock), EN 511- (rail automation); Special environmental requirements: EN 671 (corrosive gas) The actually valid operating conditions and approvals depend on the Multi-Vendor Systems HCSI HCS7I HCS7I ET S S7- S7- based on S7-/ H/F The HCS industrial heating control s permit extremely precise and efficient control of ohmic loads such as infrared heaters or : relay outputs 5 A each DM: 6 channels.5 A each IM151- / IM151-F 1C 1 KB / / n-retain / 1 KB 1 KB / 15 / 15F 17 / 17F 19 / 19F KB / 51 KB 1 KB / 1 56 KB KB / 56 KB 1 KB / KB 76 KB / 1 KB 1 KB / 1 6 KB 1 KB 1-1 KB MB 7 KB Possible via current or current/voltage detection (evaluation in ) detecting faults during parallel of.5 MB MB.5 MB MB (non-retain) ) 7 KB) 1 KB) 9% 9% 9% IEC (connection devices) IEC ( networks TCP/IP) 5% 1 / IEC ) / ) 96 KB).5 MB) 7% 5% 5% via CP 5 5 / 5 station control technology; robustness in the data link layer (hamming distance, simple structure of the user layer; asynchronous protocol for serial transmission (V./V., V.11) used for asynchronous connections (V./V., RS or RS5); can be expanded to include proprietary, manufacturer-specific functions SO_POSTER EN_Kristfeld_1 DRUCK.indd 1 1 (per central interface) Dependent on the used Dependent on the controller used Load t because digital outputs are overload LA7I HP: channel fuses 1 A V in Y mode;. kw ( V in Y mode); kw ( V in Δ mode).65 kw ( V) ( V) LA7I HP: output channels;. kw ( V) program AT CMS1 CMS ECC CMS CM- CM-1 ECC ECC1 S7-/H/F Bundle - Bundle - CMS LA7I: fuses A LA7I HP: fuses A V AC +/- 15% input voltage Operating temperature - C to +55 C 1 kg door weight kg door weight power adjustment using motor facilitates % weight reduction 1 kg 1 kg With ECC, the s for the charging infrastructure, permit standard-compliant and reliable charging of electric vehicles. matter whether you are (IE C 6151) for for (1/1 Mbit/s) Integrated or 11/ V AC 1,,, A; 1/ A switchable Bearing monitoring: DKW, K(t) according to VDI, vibration monitoring: RMS DIN ISO1- The CMS are used for monitoring mechanical components permanently. 1 kg kg Q (H bridge) unit snapshot of the FFT,, long-term trend recording RS5 V max.5 m/s max. sec (typical) RS5 (In) V max.7 m/s max.9 sec ( kg) (typical). sec (1 kg) (typical).6 sec (1 kg) (typical) Can be set between 6 A... A IEC/EN Part 1 and Part (conductive charging s for electric vehicles), charging mode, CE according to IEC 611, C-Tick 1/AC CM- CMS X-Tools software 1,.1 Hz to khz Hz to khz khz khz IEPE vibration, (digital) 6 temperature 1 Hz to 1 khz 1/AC HMI KTP 6 Public charging implemented CM- () ECC CM- ECC CM- HCS Bundle SIMATIC ET S AG :1:

o SIPLUS LOGO! MODULAR BASIC VARIANTS

o SIPLUS LOGO! MODULAR BASIC VARIANTS o SIPLUS LOGO! MODULAR BASIC VARIANTS The space-saving basic variants Interface for the connection of expansion modules, up to 24 digital inputs, 16 digital outputs, 8 analog inputs and 2 analog outputs

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

SENTRON 3VL Molded Case Circuit Breakers

SENTRON 3VL Molded Case Circuit Breakers Siemens AG SENTRON VL Molded Case Circuit Breakers Switching, Protection, Measuring and Monitoring Devices For the operating range from A to 00 A, the molded case circuit breaker ensures the optimum overload

More information

SIPLUS S7-200 PS 203. Overview

SIPLUS S7-200 PS 203. Overview SIPLUS S7-200 PS 203 Overview Design and functionality of the power supply are optimally adapted to the SIPLUS S7-200 micro PLC Slim design Particularly suitable for low cabinet depths Note: SIPLUS extreme

More information

SIPLUS S7-200 TD 400 C

SIPLUS S7-200 TD 400 C SIPLUS S7-200 TD 400 C Overview Additional screen space and high readability via backlit four-line display Customizable user interface with 15 tactile keys Audible and visual feedback upon pressing of

More information

Siemens AG /24RC 12/24RCo

Siemens AG /24RC 12/24RCo Siemens AG 008 Introduction Micro Automation LOGO!: Technology with a future which simplifies many things The compact, user-friendly and low-cost solution for simple control tasks. For universal applications

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

Unmanaged Industrial Ethernet Switches

Unmanaged Industrial Ethernet Switches Siemens AG 2017 Brochure Edition 11/2016 Un Industrial Ethernet Switches Cost-effective setup of small networks As active network components, Ethernet switches permit the structuring of an industrial communication

More information

DeltaV Bulk Power Supplies

DeltaV Bulk Power Supplies DeltaV Distributed Control System Product Data Sheet DeltaV Bulk Power Supplies DeltaV 5 A, 10A, 20 A, 40 A Bulk Power Supplies. DeltaV 20 A, 40 A and 80 A Bulk Power Supply Redundancy Modules. Easy to

More information

General information Engineering with Programming package. Display with display

General information Engineering with Programming package. Display with display Datasheet SIPLUS S7-1200 CPU 1212C AC/DC/RLY -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7212-1BE31-0XB0. COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 8 DI 24V DC 6 DO RELAY 2A 2 AI 0-10V DC, POWER

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, AC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 50 KB General information

More information

FLEX500-HF Digital Turbine Control - Hydro Francis

FLEX500-HF Digital Turbine Control - Hydro Francis PMCS-B- 0011-17 (Revision New, 08/2018) FLEX500-HF Digital Turbine Control - Hydro Francis 32-Bit processor Based Digital Control Integrated Graphical operator control panel Real time trending Trip and

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40... +70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG31-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 6 DI 24V DC; 4 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory Data sheet SIPLUS S7-1200 CPU 1214C DC/DC/DC -40...+70 DEGREES C WITH CONFORMAL COATING BASED ON 6ES7214-1AG40-0XB0. COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC 10 DO 24 V DC 2 AI 0-10V DC, POWER

More information

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, AC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA

More information

ABB component drive ACS50, 0.18 to 2.2 kw Technical catalogue PRODUCTS

ABB component drive ACS50, 0.18 to 2.2 kw Technical catalogue PRODUCTS ABB component drive ACS50, 0.18 to 2.2 kw Technical catalogue PRODUCTS ABB component drive What is an ABB component drive? The ABB component drives meet the requirements of OEMs, installation companies

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/RLY, ONBOARD I/O: 8 DI 24V DC; 6 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Product

More information

The innovative interface for the last few meters to the process

The innovative interface for the last few meters to the process Industrial Communication The innovative interface for the last few meters to the process IO-Link: optimal integration of sensors and actuators siemens.com/io-link Complete communication down to the last

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/RELAY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information

More information

Siemens AG 2010 SIMATIC RF300. RFID system in the HF range. Brochure September SIMATIC Sensors Ident. Answers for industry.

Siemens AG 2010 SIMATIC RF300. RFID system in the HF range. Brochure September SIMATIC Sensors Ident. Answers for industry. SIMATIC RF300 RFID system in the HF range Brochure September 2010 SIMATIC Sensors Ident Answers for industry. SIMATIC RF300 RFID system in the HF range SIMATIC RF300 increases productivity through shorter

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 100 KB General information Firmware

More information

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000 SICAM A8000 Series Operation, telecontrol, and automation in the smallest spaces siemens.com/sicam-a8000 4 Applications 5 Scalability in the application 6 Highlights at a glance 8 The entire product family

More information

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

General information. Display. Supply voltage. Input current. Encoder supply. Power losses Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/RELAY, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A, 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture

DeltaV SX Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy to use. Field proven architecture DeltaV Distributed Control System Product Data Sheet January 2018 DeltaV SX Controller Scalable controllers Quick assembly Easy to use Field proven architecture Designed for Electronic Marshalling Advanced

More information

5 MICROMASTER 420 specifications

5 MICROMASTER 420 specifications Issue 10/06 This Chapter contains: Table 5-1 Table 5-2 Table 5-3 Table 5-4 contains the general technical specifications for the MICROMASTER 420 inverter contains terminal tightening torques contains information

More information

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet 2CDC 251 056 F0t07 Features Rated control supply voltage 24-48 V DC, 24-240 V AC Single-function ON-delay timer One device includes 10 time ranges (0.05 s - 300 h) 1 c/o contact 2 LEDs for status indication

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, AC/DC/RLY, ONBOARD I/O: 14 DI 24V DC; 10 DO RELAY 2A; 2 AI 0-10V DC, POWER SUPPLY: AC 85-264 V AC AT 47-63 HZ, PROGRAM/DATA MEMORY: 75 KB Display with

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1217C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT ONBOARD I/O: 10 DI 24V DC; 4 DI RS422/485; 6 DO 24V DC; 0,5A; 4 DO RS422/485; 2 AI 0-10V DC, 2 AQ 0-20MA; POWER SUPPLY: DC

More information

Electronic timer CT-ERS.21

Electronic timer CT-ERS.21 2CDC 251 057 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function ON delay timer One device includes 10 time ranges (0.05 s 300 h) 2 c/o contacts 2 LEDs for status indication Width

More information

General information. Display. Supply voltage

General information. Display. Supply voltage Data sheet SIMATIC S7-1200, CPU 1211C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 6 DI 24V DC; 4 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Product

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities.

/ sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities. www.siemens.com / sicam SICAM CMIC The smart cube for your distribution network Answers for infrastructure and cities. Simply smart: The compact telecontrol unit SICAM CMIC compact micro Three-stage intelligence

More information

Operator panels Advanced HMI Panel-based Mobile Panels

Operator panels Advanced HMI Panel-based Mobile Panels Siemens AG 018 nd Generation Overview Mobile Mobile F Mobile Mobile F Mobile nd Generation Technical specifications General information 6AV15-DB3-6AV15-GB03-6AV15-GB3- F 6AV15-JB03-6AV15-JB3- F Product

More information

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture

DeltaV SQ Controller. Introduction. Benefits. Scalable controllers. Quick assembly. Easy-to-use. Field proven architecture DeltaV Distributed Control System Product Data Sheet January 2018 DeltaV SQ Controller Scalable controllers Quick assembly Easy-to-use Field proven architecture Designed for Electronic Marshalling Advanced

More information

ABB Component Drives ACS55, 0.25 to 3 Hp

ABB Component Drives ACS55, 0.25 to 3 Hp ABB Component Drives ACS55, 0.25 to 3 Hp Technical Catalog BUSINESS PROFILE INDUSTRIES PRODUCTS APPLICATIONS EXPERTISE PARTNERS SERVICES ABB Component Drive What is the ACS55 customer value? Reduces panel

More information

TM221M16TG controller M IO transistor PNP spring

TM221M16TG controller M IO transistor PNP spring Characteristics controller M221 16 IO transistor PNP spring Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact

Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARE OFF-delayed without auxiliary voltage, 1 c/o (SPDT) contact The CT-ARE is an electronic time relay with OFF-delay. It is from the CT-E range. The CT-E range is the economic

More information

M-series MQ Controller

M-series MQ Controller DeltaV Distributed Control System Product Data Sheet M-series MQ Controller Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MQ Controller provides communication

More information

MAKING MODERN LIVING POSSIBLE. VLT Micro Drive. Small drive maximum strength and reliability

MAKING MODERN LIVING POSSIBLE. VLT Micro Drive. Small drive maximum strength and reliability MAKING MODERN LIVING POSSIBLE New photo VLT Micro Drive Small drive maximum strength and reliability Ready Steady Go! Connect motor and power cables, turn the control knob, and watch the motor speed change

More information

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM3TM3 module TM3-2 temperature inputs and 1 analog output Characteristics module TM3-2 temperature inputs and 1 analog output Main Range of product Product or component type Range compatibility Analogue input number 2 Analogue input type Analogue output number

More information

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX Operator Interface Operator Station 10" display, 800 x 600 pixels with resistive foil touch screen 12 function keys Zone 2, 22 and Division 2, optional GMP- compliant enclosure Data is transmitted via

More information

Electronic timer CT-ARS.11

Electronic timer CT-ARS.11 2CDC 251 088 F0t07 Features Rated control supply voltage 24 240 V AC/DC Single function OFF delay timer without auxiliary voltage One device includes 7 time ranges (0.05 s 10 min) 1 c/o (SPDT) contact

More information

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly.

DeltaV SX Controller. DeltaV SX Controller. Introduction. DeltaV Product Data Sheet. Scalable controllers. Quick Assembly. August 2010 Page 1 The and the DeltaV I/O subsystem make rapid installation easy Scalable controllers Quick Assembly Easy to use Field Proven architecture Designed for Digital Marshalling Advanced Controls

More information

What supplies 24 V DC even with voltage fluctuations, power failures, or overload reliably?

What supplies 24 V DC even with voltage fluctuations, power failures, or overload reliably? What supplies even with voltage fluctuations, power failures, or overload reliably? SITOP power supply: the standard for reliability, compactness, and functionality Answers for industry. Always available,

More information

Engineered with TIA Portal. Heat under control. SIPLUS HCS I/O systems for industrial heating applications. siemens.com/siplus-hcs

Engineered with TIA Portal. Heat under control. SIPLUS HCS I/O systems for industrial heating applications. siemens.com/siplus-hcs Engineered with TIA Portal Heat under control SIPLUS HCS I/O systems for industrial heating applications siemens.com/siplus-hcs SIPLUS HCS pinpointed heating For precise temperature control From automobile

More information

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB Display with display Supply

More information

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current Datasheet SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 50 KB General information Engineering

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current Datasheet SIMATIC S7-1200, CPU 1214C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 14 DI 24V DC; 10 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY: 75 KB General information Engineering

More information

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current Data sheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA

More information

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages

Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of

More information

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes Datasheet SIMATIC S7-1200, CPU 1215C, COMPACT CPU, DC/DC/DC, 2 PROFINET PORT, ONBOARD I/O: 14 DI 24V DC; 10 DO 24V DC 0.5A 2 AI 0-10V DC, 2 AO 0-20MA DC, POWER SUPPLY: DC 20.4-28.8 V DC, PROGRAM/DATA MEMORY:

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

SIPLUS S7-200TD 200. Overview

SIPLUS S7-200TD 200. Overview SIPLUS S7-200TD 200 Overview The user-friendly text display for the S7-200 For operation and monitoring: display of message texts, interventions in the control program, setting of inputs and outputs Direct

More information

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges

More information

TM241C40U controller M IO transistor NPN

TM241C40U controller M IO transistor NPN Characteristics controller M241 40 IO transistor NPN Main Range of product Product or component type [Us] rated supply voltage 15/12/2018 Modicon M241 Logic controller 24 V DC Discrete input number 24

More information

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED SIGUARD Safety Combinations and Safe Load Feeders safety INTEGRATED EMERGENCY Topmost priority protection of man, machine and the environment The topmost priority is to protect man, machine and the environment

More information

Switching relay CT-IRE with 1 c/o (SPDT) contact

Switching relay CT-IRE with 1 c/o (SPDT) contact Data sheet Switching relay CT-IRE with 1 c/o (SPDT) contact The CT-IRE is a switching relay from the CT-E range. The CT-E range is the economic range of ABB s time relays and offers a cost effective price-performance

More information

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications siemens.com/sirius Answers for industry. SIRIUS 3RB24

More information

5SL Miniature Circuit Breakers

5SL Miniature Circuit Breakers 5SL Miniature Circuit Breakers BETA Low-Voltage Circuit Protection The new 5SL miniature circuit breaker is intended for use up to ka. The devices have the system features characteristic of all Siemens

More information

TM241C24T controller M IO transistor PNP

TM241C24T controller M IO transistor PNP Characteristics controller M241 24 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Feb 13, 2018 Modicon M241 Logic controller 24 V DC Discrete input number 14

More information

SITOP 3-phase 24 V DC, 20 to 40 A

SITOP 3-phase 24 V DC, 20 to 40 A Siemens AG 2013 SITOP 3-phase, 20 to 40 A /2 SITOP 20 A /2 SITOP 20 A /2 20 A /3 SITOP PSU300B 30 A /3 SITOP 40 A /3 SITOP 40 A /3 40 A /8 Ordering data and further information For AL and ECCN export regulations

More information

TM241C40R controller M IO relay

TM241C40R controller M IO relay Characteristics controller M241 40 IO relay Main Range of product Product or component type [Us] rated supply voltage Mar 09, 2017 Modicon M241 Logic controller 100...240 V AC Discrete input number 24

More information

Operator panels Advanced HMI Panel-based Comfort Panels

Operator panels Advanced HMI Panel-based Comfort Panels Siemens AG 018 Overview SIMATIC HMI Standard devices Excellent HMI functionality for demanding applications Widescreen TFT displays with 4", 7", 9", 1", 15", 19" and " diagonals (all 16 million colors)

More information

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM

UMG 20CM. 20 Channel Branch Circuit Monitoring Device with RCM 20 Channel Branch Circuit Monitoring Device with RCM RCM Harmonics via analysis channel Alarm management GridVis Analysis software 20 current channels Interfaces / communication RS485 RTU Accuracy of measurement

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4 Safety information 1 General 2 SINAMICS SINAMICS G120P Mechanical installation 3 Electrical installation 4 Technical specifications 5 Operating Instructions Control version V4.6 11/2013 A5E32845290B AA

More information

Combinable for All Applications

Combinable for All Applications Combinable for All Applications 3SE5 Position Switches www.siemens.com/sirius-detecting The Clever Answer to Information Diversity in the Field The Comprehensive Range of Position Switches 3SE5 position

More information

S-series DeviceNet Interface Card

S-series DeviceNet Interface Card DeltaV Distributed Control System Product Data Sheet S-series DeviceNet Interface Card The DeltaV S-series DeviceNet Interface Card provides the solution for interfacing to discrete actuators and sensors.

More information

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog Low Voltage Drives ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog ABB Component Drive What is the ACS55 customer value? Reduces panel size Reduces commissioning, installation and energy

More information

TM3TI4 module TM3-4 inputs temperature

TM3TI4 module TM3-4 inputs temperature Characteristics module TM3-4 inputs temperature Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input. ProData DATA LOGGER Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring 139 Smart and compact: Save energy costs through the universal

More information

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring Ethernet Pulse inputs and Pulse outputs Modbus-Ethernet gateway Thermistor input Memory 32 MB Threshold value monitoring ProData data logger 1 Smart and compact: Save energy costs through the universal

More information

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link

SIRIUS Overload Relays. SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link Integrated Motor Protection for High-Feature Applications SIRIUS 3RB24 Solid-State Overload Relays with Complete Starter Functionality via IO-Link SIRIUS Overload Relays www.siemens.com/sirius SIRIUS 3RB24

More information

Three-phase monitoring relay

Three-phase monitoring relay 2CDC 251 044 F0t08 Features Monitoring of three-phase mains for phase sequence and failure Powered by the measuring circuit 2 c/o (SPDT) contacts 1 LED for status indication Approvals R: yellow LED - relay

More information

TM221M32TK controller M IO transistor PNP

TM221M32TK controller M IO transistor PNP Characteristics controller M221 32 IO transistor PNP Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type Discrete

More information

Worldwide reliable and easy operation

Worldwide reliable and easy operation Worldwide reliable and easy operation S8VK power supplies The most compact design on the market Resistant in tough environments Push-In Plus technology for easy wiring industrial.omron.eu/s8vk 2 S8VK power

More information

DeltaV SD Plus Controller

DeltaV SD Plus Controller August 2010 Page 1 The and the DeltaV I/O subsystem make rapid installation easy Scalable controllers Quick Assembly Easy to use Field Proven architecture Designed for Digital Marshalling Advanced Controls

More information

Operator panels Basic HMI Basic Panels

Operator panels Basic HMI Basic Panels Siemens AG 018 Overview ( nd Generation) SIMATIC HMI ( nd Generation) with their fully developed HMI basic functions are the ideal entry-level series for simple HMI applications. The device family offers

More information

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity

DeltaV MQ Controller. Introduction. Benefits. Increases productivity. Easy to use. Has the flexibility to meet your needs. Increases productivity DeltaV Distributed Control System Product Data Sheet October 2017 DeltaV MQ Controller Increases productivity Easy to use Has the flexibility to meet your needs Introduction The MQ Controller provides

More information

General information. Display. Control elements

General information. Display. Control elements Data sheet SIMATIC HMI KTP400 BASIC MONO PN, BASIC PANEL, KEY AND TOUCH OPERATION, 4" STN DISPLAY, 4 GRAY SCALES, PROFINET INTERFACE, CONFIGURATION FROM WINCC FLEXIBLE 2008 SP2 COMPACT/ WINCC BASIC V10.5/

More information

SITOP power supply 24 V nonstop. The standard for reliability, compactness and functionality. siemens.com/sitop

SITOP power supply 24 V nonstop. The standard for reliability, compactness and functionality. siemens.com/sitop SITOP power supply 24 V nonstop The standard for reliability, compactness and functionality siemens.com/sitop Always available, always safe: SITOP A reliable, constant supply of power is indispensable

More information

SIMATIC ET 200SP and ET 200MP

SIMATIC ET 200SP and ET 200MP Engineered with TIA Portal siemens.com/et200 SIMATIC ET 200SP and ET 200MP Simple to use, smaller in size, stronger in performance Intuitive, efficient, proven TIA Portal redefines engineering Answers

More information

TM3AI4 module TM3-4 analog inputs

TM3AI4 module TM3-4 analog inputs Characteristics module TM3-4 analog inputs Main Range of product Product or component type Range compatibility Analogue input number 4 Analogue input type Complementary Analogue input resolution Permissible

More information

Redundancy unit CP-A RU

Redundancy unit CP-A RU 2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power

More information

TM221M16R controller M IO relay

TM221M16R controller M IO relay Product data sheet Characteristics TM221M16R controller M221 16 IO relay Complementary Main Discrete I/O number 16 Number of I/O expansion module Supply voltage limits Inrush current Power consumption

More information

RM17UB3. Price* : USD

RM17UB3. Price* : USD Characteristics voltage control relay RM17-U - range 183..528 V AC Product availability : Stock - Normally stocked in distribution facility Price* : 189.00 USD Main Range of product Product or component

More information

TM221CE24T controller M IO transistor PNP Ethernet

TM221CE24T controller M IO transistor PNP Ethernet Characteristics controller M221 24 IO transistor PNP Ethernet Main Range of product Product or component type [Us] rated supply voltage Discrete input number Analogue input number Discrete output type

More information

5 MICROMASTER 440 specifications

5 MICROMASTER 440 specifications Issue 10/06 This Chapter contains: Table 5.1 Table 5-2 Table 5-3 Table 5-4 Table 5-5 contains the general technical specifications for the MICROMASTER 440 inverter contains dimensions, the required cooling

More information

I/O Modules with EtherNet/IP Architecture

I/O Modules with EtherNet/IP Architecture ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION 5069 Compact I/O Modules with EtherNet/IP Architecture Note: Procurement Specification for CompactLogix 5380 Programmable Automation

More information

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX Operator Interface Operator Station 10" display, 640 x 480 pixels with resistive foil touch screen 12 function keys, 10 soft keys, 30 alphanumeric keys Zone 1, 2, 21, 22 and Division 2, optional GMP- compliant

More information

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A DATA SHEET DEPRECATED - PCM DEIF A/S Frisenborgvej DK-800 Skive Tel.: +4 64 64 Fax: +4 64 6 info@deif.com www.deif.com Document no.: N/A AWC 00 PCM data sheet - DEPRECATED. AWC 00 system. System specifications...

More information

LOGO! logic modules LOGO! basic and expansion modules

LOGO! logic modules LOGO! basic and expansion modules Siemens AG 018 LOGO! basic modules with display Overview The space-saving basic variants Interface for the connection of expansion modules, up to 4 digital inputs, 0 digital outputs, 8 analog inputs and

More information

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input

TM241C24R. Main. Discrete output type. Discrete output number. 14 (remote I/O architecture) 50 µs turn-on operation with I0...I13 terminal(s) input Product datasheet Characteristics TM241C24R Complementary Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Discrete input logic Discrete input voltage Discrete

More information

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ERD ON-delayed with 1 c/o contact Data sheet 2CDC 251 002 F0003 CT-ERD 6 5 1 2 3 4 1 7 selectable time ranges, from 0.05 s to 100 h, for the adjustment of the time delay 2 Potentiometer with direct reading scale for the fine adjustment of the time

More information