OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FDNA-01 DeviceNet adapter module User s manual

Size: px
Start display at page:

Download "OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FDNA-01 DeviceNet adapter module User s manual"

Transcription

1 OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FDNA-01 DeviceNet adapter module User s manual

2 List of related manuals See section Related manuals on page 15. You can find manuals and other product documents in PDF format on the Internet. See section Document library on the Internet on the inside of the back cover. For manuals not available in the Document library, contact your local ABB representative. The code below opens an online listing of the manuals applicable to the product: FDNA-01 manual Fieldbus connectivity webpage

3 User s manual FDNA-01 DeviceNet adapter module Table of contents 1. Safety instructions 4. Mechanical installation 5. Electrical installation 6. Start-up 3AFE Rev G EN EFFECTIVE: ABB Oy All Rights Reserved.

4

5 Table of contents Table of contents 5 1. Safety instructions What this chapter contains Use of warnings Safety in installation About the manual What this chapter contains Purpose of the manual Applicability Compatibility Target audience Before you start Related manuals Contents Cyber Security Disclaimer Terms and abbreviations used in this manual General terms and abbreviations DeviceNet terms and abbreviations Overview of the DeviceNet network and the FDNA-01 module What this chapter contains DeviceNet network Example topology of the DeviceNet link FDNA-01 DeviceNet adapter module Layout of the adapter module Mechanical installation What this chapter contains Necessary tools and instructions Unpacking and examining the delivery Installing the adapter module

6 6 Table of contents 5. Electrical installation What this chapter contains Necessary tools and instructions General cabling instructions Connecting the module to the DeviceNet network Terminal block description Connection examples Switching on the bus termination Start-up What this chapter contains Drive configuration DeviceNet connection configuration FDNA-01 configuration parameters group A (group 1) 35 FDNA-01 configuration parameters group B (group 2) 45 FDNA-01 configuration parameters group C (group 3) 46 Control locations Starting up ACS355 drives Parameter setting examples ACS ABB Drives profile ODVA AC/DC drive profile Starting up ACSM1 drives Parameter setting examples ACSM ABB Drives profile ODVA AC/DC drive profile Starting up ACS850 and ACQ810 drives Parameter setting examples ACS850 and ACQ ABB Drives profile ODVA AC/DC drive profile Starting up ACS880, ACS580, ACQ580, ACH580, ACS580 drives 63 Parameter setting examples ACS ABB Drives profile ODVA AC/DC drive profile Configuring the master station EDS files

7 Table of contents 7 Configuring an Allen-Bradley PLC Communication profiles What this chapter contains Communication profiles ODVA AC/DC drive profile ODVA output attributes Run Forward & Run Reverse (Control supervisor object) Fault Reset (Control supervisor object) Net Ctrl (Control supervisor object) Net Ref (AC/DC drive object) Speed Reference (AC/DC drive object) Torque Reference (AC/DC drive object) ODVA input attributes Faulted (Control supervisor object) Warning (Control supervisor object) Running Forward (Control supervisor object) Running Reverse (Control supervisor object) Ready (Control supervisor object) Ctrl From Net (Control supervisor object) Ref From Net (AC/DC drive object) At Reference (AC/DC drive object) State (Control supervisor object) Speed Actual (AC/DC drive object) Torque Actual (AC/DC drive object) ABB Drives communication profile Control word and Status word Control word contents Status word contents State machine References Scaling Actual values Scaling

8 8 Table of contents 8. Communication protocol What this chapter contains DeviceNet Object modeling and functional properties Assembly objects Basic speed control assembly Basic speed control plus drive parameters assembly Extended speed control assembly Extended speed control plus drive parameters assembly. 100 Basic speed and torque control assembly Basic speed and torque control plus drive parameters assembly Extended speed and torque control assembly Extended speed and torque control plus drive parameters assembly ABB Drives profile with set speed assembly ABB Drives profile with set speed plus drive parameters assembly ABB Drives profile with set speed and set torque assembly ABB Drives profile with set speed and set torque plus drive parameters assembly Transparent 16 with one assembly Transparent 16 with one assembly plus drive parameters 117 Transparent 16 with two assembly Transparent 16 with two assembly plus drive parameters. 120 Transparent 32 with one assembly Transparent 32 with one assembly plus drive parameters 124 Transparent 32 with two assembly Transparent 32 with two assembly plus drive parameters. 128 Class objects Identity object, class 01h Class attributes (Instance #0) Instance attributes (Instance #1) Attribute explanations DeviceNet object, class 03h

9 Table of contents 9 Class attributes Instance attributes Connection object, class 05h Class attributes Instance attributes Acknowledge handler object, class 2Bh Class attributes (Instance #0) Instance attributes (Instance #1) Motor data object, class 28h Class attributes (Instance #0) Instance attributes (Instance #1) Control supervisor object, class 29h Class attributes (Instance #0) Instance attributes (Instance #1) AC/DC-drive object, class 2Ah Class attributes (Instance #0) Instance attributes (Instance #1) Drive parameter object, Class 90h Fieldbus configuration object 91h Class attributes Instance #1: FDNA-01 configuration parameters group A (group 1) Instance #2: FDNA-01 configuration parameters group B (group 2) Instance #3: FDNA-01 configuration parameters group C (group 3) Diagnostics What this chapter contains Fault and warning messages LED indications Technical data What this chapter contains FDNA DeviceNet link

10 10 Table of contents 11. Appendix A Varying the number of drive parameters What this chapter contains Modification of the EDS file Further information

11 Safety instructions 11 1 Safety instructions What this chapter contains The chapter contains the warning symbols used in this manual and the safety instructions which you must obey when you install or connect an optional module to a drive, converter or inverter. If you ignore the safety instructions, injury, death or damage can occur. Read this chapter before you start the installation. Use of warnings Warnings tell you about conditions which can cause injury or death and, or damage to the equipment. They also tell you how to prevent the danger. The manual uses these warning symbols: Electricity warning tells you about hazards from electricity which can cause injury or death, or damage to the equipment.

12 12 Safety instructions General warning tells you about conditions, other than those caused by electricity, which can cause injury or death, or damage to the equipment. Safety in installation These instructions are for all who install or connect an optional module to a drive, converter or inverter and need to open its front cover or door to do the work. WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur. If you are not a qualified electrician, do not do installation or maintenance work. Disconnect the drive, converter or inverter from all possible power sources. After you have disconnected the drive, converter or inverter, always wait for 5 minutes to let the intermediate circuit capacitors discharge before you continue. Disconnect all dangerous voltages connected to other control signal connectors in reach. For example, it is possible that 230 V AC is connected from outside to a relay output of the drive, converter or inverter. Always use a multimeter to make sure that there are no parts under voltage in reach. The impedance of the multimeter must be at least 1 Mohm.

13 About the manual 13 2 About the manual What this chapter contains This chapter introduces this manual. Purpose of the manual The manual provides information on installing, commissioning and using an FDNA-01 DeviceNet adapter module. Applicability This manual applies to the FDNA-01 DeviceNet adapter module (+K451), SW version 2.30 or later.

14 14 About the manual Compatibility The FDNA-01 DeviceNet adapter module is compatible with the following drives: ACS355 ACSM1 ACS380 ACH580 ACQ580 ACS580 ACS850 ACQ810 ACS880. The FDNA-01 DeviceNet adapter module is compatible with all master stations that support the DeviceNet protocol. Note: The adapter module is compatible with more drives that may not be listed here. For details of compatibility, check the drive s firmware manual. Target audience This manual is intended for people who plan the installation, install, start up, use and service the adapter module. Before you do work on the module, read this manual and the applicable drive manual that contains the hardware and safety instructions for the product in question. You are expected to know the fundamentals of electricity, wiring, electrical components and electrical schematic symbols. The manual is written for readers worldwide. Both SI and imperial units are shown.

15 About the manual 15 Before you start It is assumed that the drive is installed and ready to operate before you start the installation of the adapter module. In addition to conventional installation tools, have the drive manuals available during the installation as they contain important information not included in this manual. The drive manuals are referred to at various points of this manual. Related manuals The related manuals are listed below. Drive manuals and guides Code (EN/Multilingual) ACSM1 manuals ACS manuals 9AAK10103A6193 ACH manuals 9AKK10103A0587 ACH manuals 9AKK106930A9059 ACH manuals 9AKK106930A5241 ACQ manuals 9AKK106713A2709 ACQ manuals 9AKK106930A9053 ACQ manuals 9AKK106930A3150 ACS manuals 9AKK105713A8085 ACS manuals 9AKK106930A9060 ACS (75 to 250 kw) manuals 9AKK106930A5239 ACS (250 to 500 kw) 9AKK106713A0278 ACQ810 manuals ACS manuals ACS manuals 9AKK105408A7004 ACS manuals 9AKK105713A4819 ACS manuals (45 to 710 kw) 9AKK105408A8149 ACS (560 to 2800 kw) 9AKK105713A6663 ACS (132 to 355 kw) 9AKK106930A3466 ACS (160 to 3200 kw) 9AKK106354A1499 ACS (132 to 355 kw) 9AKK106930A3467 ACS (160 to 3200 kw) 9AKK106354A1500 Option manuals and guides FDNA-01 DeviceNet adapter module user s manual FDNA-01 DeviceNet adapter module quick guide 3AFE AXD

16 16 About the manual Contents The manual consists of the following chapters: Safety instructions contains the safety instructions which you must follow when installing a fieldbus adapter module. About the manual introduces this manual. Overview of the DeviceNet network and the FDNA-01 module contains a short description of the DeviceNet network and the adapter module. Mechanical installation contains a delivery checklist and instructions to install the adapter module. Electrical installation contains cabling and bus termination instructions and instructions on connecting the module to the DeviceNet network. Start-up presents the steps to take during the start-up of the drive with the adapter module and gives examples of configuring the master system. Communication profiles describes the communication profiles used in the communication between the DeviceNet network, the adapter module and the drive. Communication protocol describes the DeviceNet communication protocol for the adapter module and the configuration of the scanner. Diagnostics explains how to trace faults with the status LEDs on the adapter module. Technical data contains the technical data of the adapter module and the DeviceNet link. Appendix A Varying the number of drive parameters describes how to reduce the number of drive parameter members in FDNA-01 assemblies by modifying the EDS file.

17 About the manual 17 Cyber Security Disclaimer This product is designed to be connected to and to communicate information and data via a network interface. It is Customer's sole responsibility to provide and continuously ensure a secure connection between the product and Customer network or any other network (as the case may be). Customer shall establish and maintain any appropriate measures (such as but not limited to the installation of firewalls, application of authentication measures, encryption of data, installation of anti-virus programs, etc.) to protect the product, the network, its system and the interface against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB and its affiliates are not liable for damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft of data or information. Note: The web pages are meant only for configuring the device during commissioning. For security reasons, it is recommended to disable the web pages after commissioning.

18 18 About the manual Terms and abbreviations used in this manual General terms and abbreviations Term Command word Communication module Control word DCU profile DTC FBA profile FDNA-01 DeviceNet adapter module LSW MSW Parameter Profile Explanation See Control word. Communication module is a name for a device (eg, a fieldbus adapter) through which the drive is connected to an external communication network (eg, a fieldbus). The communication with the module is activated with a drive parameter. 16-bit or 32-bit word from master to slave with bit-coded control signals (sometimes called the Command word). Drive Control Unit profile, native profile used in the ACS350 and ACS355 drives Direct Torque Control is a motor control method for AC drives. DTC allows accurate control of both motor speed and torque without pulse encoder feedback from the motor shaft. Fieldbus Adapter profile, native profile used in the ACQ810, ACS850 and ACSM1 drives One of the optional fieldbus adapter modules available for ABB drives. FDNA-01 is a device through which an ABB drive is connected to a DeviceNet serial communication bus. Least significant word Most significant word An operating instruction for the drive. Parameters can be read and programmed with the drive control panel, drive PC tools or through the adapter module. Adaptation of the protocol for certain application field, for example, drives. In this manual, drive-internal profiles (eg, DCU or FBA) are called native profiles.

19 About the manual 19 Term RFG Status word Explanation Ramp Function Generator 16-bit or 32-bit word from slave to master with bit-coded status messages DeviceNet terms and abbreviations Term Change of State/Cyclic Message CIP EDS File Input I/O assembly selection MAC ID Explanation Change of State/Cyclic Message is transmitted by either the master or the slave. A Change of State/Cyclic Message is directed towards a single specific node (point-to-point). An Acknowledge Message may be returned in response to this message. Common Industrial Protocol (CIP) is an industrial protocol for industrial automation applications. It is managed by ODVA. Electronic Data Sheet (EDS) file identifies the properties of the device to the DeviceNet Scanner. Each type of drive and application program requires its own EDS file. In the ODVA DeviceNet specification the word input is used to describe data flow from a device (such as FDNA-01) to the network. Smart networked devices (like FDNA-01) can produce and/or consume more than one I/O value. Typically, they produce and/or consume one or more I/O value, as well as status and diagnostic information. Each piece of data communicated by a device is represented by an attribute of one of the device s internal objects. Communicating multiple pieces of data (attributes) across a single I/O connection requires that the attributes be grouped or assembled together into a single block. Every node on DeviceNet network has to have a unique identifier. This node number is called MAC ID (Media Access Control Identifier).

20 20 About the manual Term ODVA Output Poll Message Scanlist Explanation ODVA stands for Open DeviceNet Vendor Association. ODVA is an independent organization that promotes interoperativity between different manufacturers DeviceNet products. ABB is an Associate Member at ODVA. In the ODVA DeviceNet specification the word output is used to describe data flow from the network into a device (such as FDNA-01). Most DeviceNet Scanners as well as the FDNA- 01 module support two different data services. These are Poll and Change of State/Cyclic messages. The Poll Command is an I/O Message that is transmitted by the master. A Poll Command is directed towards a single, specific slave (pointto-point, FDNA-01 always acts as a slave). A master must transmit a separate Poll Command Message for each of its slaves that is to be polled. The Poll Response is an I/O Message that a slave transmits back to the master when the Poll Command is received. DeviceNet Scanner communicates with the DeviceNet slaves in a user-defined order. This order of communication is the scanlist. The scanlist contains a complete list of the slave nodes and the order in which the slaves are accessed.

21 Overview of the DeviceNet network and the FDNA-01 module 21 3 Overview of the DeviceNet network and the FDNA-01 module What this chapter contains This chapter contains a short description of the DeviceNet network and the FDNA-01 DeviceNet adapter module. DeviceNet network The DeviceNet network has a linear bus topology. Terminating resistors are required on each end of the trunk line. Drop lines as long as 6 metres (20 feet) each are permitted, allowing one or more nodes to be attached. DeviceNet allows branching structures only on drop lines. The maximum length of the trunk cable depends on the data rate and on the type of the cable used (see chapter Technical data).

22 22 Overview of the DeviceNet network and the FDNA-01 module Example topology of the DeviceNet link The figure below shows an example of an allowable topology of FDNA-01. Trunk line Tap Node Node Node Terminating Resistor Tap Tap Node Node Node Tap Node Node Node Drop line Node Node

23 Overview of the DeviceNet network and the FDNA-01 module 23 FDNA-01 DeviceNet adapter module The FDNA-01 DeviceNet Adapter module is an optional device for ABB drives. It enables the connection of the drive to a DeviceNet network. The drive is considered a slave in the DeviceNet network. Through the adapter module you can: give control commands to the drive (for example, Start, Stop, Run enable) feed a motor speed or torque reference to the drive give the actual value or reference of the process to the PID controller of the drive read status information and actual values from the drive change drive parameter values reset a drive fault. The adapter module acts as a class 2 slave only with predefined master-slave connection set services. These include the explicit messaging, the poll-response service and the change of state/ cyclic service. The DeviceNet commands and services supported by the adapter module are described in chapter Communication protocol. The adapter module is mounted into an option slot on the motor control board of the drive. See the drive manuals for the module placement options.

24 24 Overview of the DeviceNet network and the FDNA-01 module Layout of the adapter module The figure shows the layout of FDNA No. Description See chapter 1 Lock Mechanical installation 2 Mounting screw Mechanical installation 3 Bus connector X1 Electrical installation 4 Diagnostic LEDs Diagnostics

25 Mechanical installation 25 4 Mechanical installation What this chapter contains This chapter contains a delivery checklist and instructions to install the adapter module. Necessary tools and instructions You will need a Torx TX10 screwdriver to secure the FDNA adapter module to the drive. See also, the applicable drive hardware manual. Unpacking and examining the delivery 1. Open the option package. 2. Make sure that the package contains: DeviceNet adapter module, type FDNA-01 this manual. 3. Make sure that there are no signs of damage.

26 26 Mechanical installation Installing the adapter module WARNING! Obey the safety instructions. See chapter Safety instructions on page 11. If you ignore the safety instructions, injury or death can occur. The adapter module has a specific position in the drive. You can plug and unplug the adapter when the drive is power off and no external 24 voltage supplied to the control board. Plastic pins, a lock and one screw to hold the adapter module in place. The screw also makes an electrical connection between the module and drive frame for cable shield termination. When the adapter module is installed, it makes the signal and power connection to the drive through a 20-pin connector. When you install or remove the adapter module from the control unit: 1. Pull out the lock. 1

27 Mechanical installation Put the adapter module carefully into its position on the drive. 3. Push in the lock Tighten the screw to torque 0.8 N m using a Torx TX10 screwdriver. Note: A too high torque may break the screws. It is necessary to tighten the screw properly to fulfill the EMC requirements and to ensure the proper operation of the module. See the applicable drive manual for further instructions on how to install the adapter module to the drive.

28 28 Mechanical installation

29 Electrical installation 29 5 Electrical installation What this chapter contains This chapter contains: general cabling instructions instructions on connecting the module to the DeviceNet network instructions on switching on the bus termination. WARNING! Obey the safety instructions. See chapter Safety instructions on page 11. If you ignore the safety instructions, injury or death can occur. If you are not a qualified electrician, do not do electrical work. Necessary tools and instructions See the applicable drive hardware manual.

30 30 Electrical installation General cabling instructions Arrange the bus cables as far away from the motor cables as possible. Avoid parallel runs. Use bushings at cable entries. Connecting the module to the DeviceNet network Connect the bus cable to terminal block X1 on the adapter module. Terminal block description X1 Description 1 V- Network power supply ground (0V DC) 2 CAN_L CAN_L bus line 3 SHLD Network cable shield 4 CAN_H CAN_H bus line 5 V+ Network power supply source (24V DC) Connection examples 5-pin micro-style connector: Network 0 V power supply +24 V Male micro-style connector V- CAN_L SHLD CAN_H V FDNA X1

31 Electrical installation 31 5-pin mini-style connector: Network power supply Male mini-style connector V +24 V V- CAN_L SHLD CAN_H V FDNA X1 Standard open-style screw connector: Network power supply +24 V 0 V V- CAN_L SHLD CAN_H V FDNA X1 Switching on the bus termination The adapter module does not provide bus termination. The DeviceNet network should be terminated at both ends of the trunk cable with a 121 ohm, ¼ W, 1% metal film resistor. Connect the resistor between the two signal wires (CAN_H, CAN_L) on the DeviceNet cable, as shown in the figure below. Scanner Node 1 Node n CAN_H 121 Ω 1% Metal Film 1/4 W CAN_L 121 Ω 1% Metal Film 1/4 W Further information on the DeviceNet protocol is available at

32 32 Electrical installation

33 Start-up 33 6 Start-up What this chapter contains This chapter contains: information on configuring the drive for operation with the adapter module drive-specific instructions on starting up the drive with the adapter module examples of configuring the master station for communication with the adapter module. WARNING! Obey the safety instructions given in this manual and the drive documentation.

34 34 Start-up Drive configuration The following information applies to all drive types compatible with the adapter module, unless otherwise stated. DeviceNet connection configuration After the adapter module has been mechanically and electrically installed according to the instructions in chapters Mechanical installation and Electrical installation, the drive must be prepared for communication with the module. The detailed procedure of activating the module for DeviceNet communication with the drive depends on the drive type. Normally, a parameter must be adjusted to activate the communication. See the drive-specific start-up procedures starting on page 47. Once communication between the drive and the adapter module has been established, several configuration parameters are copied to the drive. These parameters are shown in the tables below and must be checked first and adjusted where necessary. Note: Not all drives display descriptive names for the configuration parameters. To help you identify the parameters in different drives, the names displayed by each drive are given in grey boxes in the tables. Note: The new settings take effect only when the adapter module is powered up the next time or when the fieldbus adapter refresh parameter is activated. Note: If communication between the adapter module and DeviceNet master is established, changes to the configuration parameters can be done also through Fieldbus configuration object 91h.

35 Start-up 35 FDNA-01 configuration parameters group A (group 1) Note: The actual parameter group number depends on the drive type. Group A (group 1) corresponds to: parameter group 51 in ACS355, ACSM1, ACS850 and ACQ810 parameter group 51 in ACS880 if the adapter is installed as fieldbus adapter A or group 54 if the adapter is installed as fieldbus adapter B. No. Name/Value Description Default 01 FBA TYPE Read-only. Shows the fieldbus adapter type as detected by the drive. Value cannot be adjusted by the user. If the value is 0 = None, the communication between the drive and the module has not been established. 02 MAC ID Defines the MAC ID number for the drive the adapter module is connected to. Each device on the DeviceNet network must have a unique MAC ID number MAC ID 03 Baud rate Indicates the detected communication speed in kbit/s. 0 = 125 kbit/s Communication speed is 125 kbit/s. 1 = 250 kbit/s Communication speed is 250 kbit/s. 2 = 500 kbit/s Communication speed is 500 kbit/s. 04 Drive profile Defines the communication used between the module and the drive (not fieldbus and module). If a drive supports more than one drive profile, this parameter is used to select the preferred profile. Presently, to use the ODVA and ABB Drives profiles, the drive must support a native profile (eg, DCU or FBA). Transparent16 and Transparent32 profiles may be used with any drive profile. 0 = Native prof Native profile of the drive selected 05 ODVA stop func Used with the ODVA AC/DC drive profile. Determines how the motor is stopped when a stop command is received via DeviceNet. 0 = Ramp stop Motor decelerates along the active deceleration ramp. 1 = DeviceNet 63 0 = 125 kbit/s 0 = Native prof 0 = Ramp stop

36 36 Start-up No. Name/Value Description Default 1 = Coast stop Motor comes to a stop by coasting. 06 Output instance Configures the output assembly instances used by the adapter module. Tables below list the supported assemblies and allowed combinations. For the descriptions of the assembly instances, see section Assembly objects on page Name Output instance Input Default instance input size (bytes) Profile Basic speed control ODVA AC/DC drive Extended speed ODVA AC/DC drive control Basic speed and ODVA AC/DC drive torque control Extended speed and ODVA AC/DC drive torque control Basic speed control ODVA AC/DC drive plus drive parameters Extended speed control plus drive parameters ODVA AC/DC drive Basic speed and torque control plus drive parameters Extended speed and torque control plus drive parameters ABB Drives profile with set speed ABB Drives profile with set speed and set torque (continued) ODVA AC/DC drive ODVA AC/DC drive ABB Drives ABB Drives

37 Start-up 37 No. Name/Value Description Default Name (continued) ABB Drives profile with set speed plus drive parameters ABB Drives profile with set speed and set torque plus drive parameters ABB Drives profile with set speed plus drive parameters Transparent16 with one Transparent16 with two Transparent16 with one plus drive parameters Transparent16 with two plus drive parameters Transparent32 with one Transparent32 with two Transparent32 with one plus drive parameters Transparent32 with two plus drive parameters Output instance Input Default instance input size (bytes) Profile ABB Drives ABB Drives ABB Drives Transparent Transparent Transparent Transparent Transparent Transparent Transparent Transparent32

38 38 Start-up No. Name/Value Description Default Note: With ACSM1, ACQ810, ACS850 and ACS880, when using the ODVA AC/DC drive or ABB Drives profile, make sure that drive parameter FBA REF MODESEL is set to SPEED. With ACSM1, ACS850 and ACS880, make sure that FBA REF2 MODESEL is set to TORQUE. Output Input ODVA ABB DRIVES TRANSPARENT16 TRANSPARENT32 (70-73; ) ( ; ( ; ) ( ; ) ODVA (20-23; ) x ABB DRIVES ( ; ) x TRANSPARENT16 ( ; ) x TRANSPARENT32 ( ; ) x For alternative values, see column Output instance in the table describing parameter 06 Output instance. 07 Output num pars Some assembly instances support transferring drive parameter values between the I/O scanner and drive. Parameters 07 Output num pars and 09 Input num pars specify how many drive parameter values should be included in the respective assembly instance. Changing the numbers of the drive parameters to values other than the defaults also changes the lengths of the associated assembly instances. This requires manual changes to either the EDS file or I/O scanner configuration. Before changing these parameters, consult Appendix A Varying the number of drive parameters. Note: This parameter is only used when the output assembly instance is 120, 121, 122, 123, 901, 902, 911, 912, 921, 922. It must always be set to the default, 10, except as described in Appendix A Varying the number of drive parameters Number or drive parameter values to be included in the assembly instance. 08 Input instance Configures the input assembly instances used by the adapter module. See parameter 06 Output instance. For alternative values, see parameter 06 Output instance

39 Start-up 39 No. Name/Value Description Default 09 Input num pars See parameter 07 Output num pars. Note: This parameter is only used when the input assembly instance is 170, 171, 172, 173, 951, 952, 961, 962, 971, 972. It must always be set to the default, 10, except as described in Appendix A Varying the number of drive parameters Number or drive parameter values to be included in the assembly instance. 10

40 40 Start-up No. Name/Value Description Default 10 ODVA speed scale Defines the speed scale in the ODVA AC/DC drive profile. Units of reference and actual speeds for the ODVA AC/DC drive profile are given by the formula below. No effect on the ABB Drives profiles. Note: While a wide range of resolutions may be configured, the actual performance is limited to the performance capabilities of the drive. (-1 X ODVA speed scale value) Speed unit = RPM X Table below shows how the values of drive parameter ODVA SPEED SCALE correspond to the ODVA Speed Scale units. ODVA speed scale value 1) Speed scale value of Unit drive parameter 2) RPM RPM RPM RPM RPM 0 (default) RPM RPM RPM RPM RPM RPM 1) Use the ODVA speed scale value when reading/writing parameter ODVA speed scale via AC/DC-drive object, class 2Ah. When written via the AC/DC drive object, the new value takes effect immediately. 2) Use the speed scale value of the drive parameter when reading/writing parameter ODVA speed scale via the drive control panel, Drive parameter object, Class 90h and Fieldbus configuration object 91h. When written via these methods, the new value takes effect after the drive is repowered or a Fieldbus Adapter Parameter refresh is given Speed scale value of the drive parameter

41 Start-up 41 No. Name/Value Description Default ODVA torque scale Defines the torque scale in the ODVA AC/DC drive profile. Units of reference and actual torques for the ODVA AC/DC drive profile are given by the formula below. No effect on the ABB Drives profiles. Note: While a wide range of resolutions may be configured, the actual performance is limited to the performance capabilities of the drive. (N m = Newton x Meter) (-1 X ODVA torque scale) Torque unit = N m x 2 Table below shows how the values of drive parameter ODVA TORQUE SCALE correspond to the ODVA Torque Scale units. ODVA torque scale value 1) Torque scale value of Unit drive parameter 2) N m N m N m N m N m 0 (default) N m N m N m N m N m N m 1) Use the ODVA torque scale value when reading/writing parameter ODVA torque scale via AC/DC-drive object, class 2Ah. When written via the AC/DC drive object, the new value takes effect immediately. 2) Use the torque scale value of the drive parameter when reading/writing parameter ODVA torque scale via the drive control panel, Drive parameter object, Class 90h and Fieldbus configuration object 91h. When written via these methods, the new value takes effect after the drive is repowered or a Fieldbus Adapter Parameter refresh is given Torque scale value of the drive parameter Reserved Not used by the adapter module. N/A

42 42 Start-up No. Name/Value Description Default 26 Unrecover. error Read-only. Shows information about the cause of an unrecoverable error in the adapter module. Bit field parameter, that is, several status bits can be set at a time. Value 0 indicates that there are no errors. Bit Name Value Description 1 DUP_MAC_ERROR 0x0001 Duplicate MAC ID error 2 RX_QUEUE_OVERRUN 0x0002 Message receive queue is full. 3 TX_QUEUE_OVERRUN 0x0004 Message transmit queue is full. 4 IO_SEND_ERROR 0x0008 Transmitting I/O data has failed. 5 CAN_BUS_OFF 0x0010 Bus-off is detected. 6 CAN_OVERRUN 0x0020 CAN message was lost. 7 DNS_RESET 0x0040 DeviceNet driver of the module is reset. 8 DNS_BUS_SENSE_ERROR 0x0080 No voltage detected in the network. 9 DNS_SWITCH_ERROR 0x0100 DeviceNet driver reset failed due to an invalid MAC ID or baud rate. 13 SYS_FILE_ERR 0x1000 Initialization with the drive failed Active unrecoverable errors 27 FBA par refresh Validates any changed adapter module configuration parameter settings. After refreshing, the value reverts automatically to 0 = Done. Note: This parameter cannot be changed while the drive is running. 0 = Done Refreshing done 1 = Refreshing Refresh/Configure 28 Par table ver Read-only. Displays the parameter table revision of the fieldbus adapter module mapping file stored in the memory of the drive. In format xyz, where x = major revision number y = minor revision number z = correction number OR in format axyz, where a = major revision number xy = minor revision numbers z = correction number or letter. 0x0000 0xFFFF Parameter table revision 0 = Done N/A

43 Start-up 43 No. Name/Value Description Default 29 Drive type code Read-only. Displays the drive type code of the fieldbus adapter module mapping file stored in the memory of the drive Drive type code of the fieldbus adapter module mapping file 30 Mapping file ver Read-only. Displays the fieldbus adapter module mapping file revision stored in the memory of the drive in decimal format. Example: 0x107 = revision Mapping file revision 31 D2FBA comm sta Read-only. Displays the status of the fieldbus adapter module communication. Note: The value names may vary by drive. 0 = Idle Adapter is not configured. 1 = Exec.init Adapter is initializing. 2 = Time out Time-out has occurred in the communication between the adapter and the drive. 3 = Conf.err Adapter configuration error: Major or minor revision code of the common program revision in the fieldbus adapter module is not the revision required by the module or mapping file upload has failed more than three times. 4 = Off-line Adapter is off-line. 5 = On-line Adapter is on-line. 6 = Reset Adapter is performing a hardware reset. 32 FBA comm SW ver 0x0000 0xFFFF Read-only. Displays the common program revision of the adapter module in format axyz, where: a = major revision number xy = minor revision numbers z = correction number or letter. Example: 190A = revision 1.90A Common program version of the adapter module N/A N/A 0 = Idle N/A

44 44 Start-up No. Name/Value Description Default 33 FBA appl SW ver Read-only. Displays the application program revision of the adapter module in format axyz, where: a = major revision number xy = minor revision numbers z = correction number or letter. Example: 190A = revision 1.90A 0x0000 0xFFFF Application program revision of the adapter module N/A

45 Start-up 45 FDNA-01 configuration parameters group B (group 2) Note: The actual parameter group number depends on the drive type. Group B (group 2) corresponds to: parameter group 55 in ACS355 parameter group 53 in ACSM1, ACS380, ACH580, ACQ580, ACS580, ACS850 and ACQ810 parameter group 53 in ACS880 if the adapter is installed as fieldbus adapter A or group 56 if the adapter is installed as fieldbus adapter B. No. 1) Name/Value Description Default 01 FBA data out1 (master to drive) In the output assembly instances that include drive parameters, this parameter specifies which parameter s value is placed in location DATA OUT 1 value received by the drive from the DeviceNet network. Content is defined by a decimal number in the range of 0 to 9999 as follows: Note: The FDNA-01 configuration parameters are 16-bit parameters. If the mapped parameter is a 32-bit parameter, it automatically reserves two consecutive parameters. For example, mapping a 32-bit parameter to parameter no. 1 also reserves parameter no Not used Parameter index with format xxyy, where xx is the parameter group number (1 99) and yy is the parameter number index within that group (01 99). DATA OUT 2 DATA OUT 10 0 Not used 1 99 Virtual address area of drive control. Not used with the FDNA-01 module. 101 Parameter area of the drive 9999 See parameter FBA data out1. 0 1) The number of parameters in this group may vary by drive type and drive firmware. 0

46 46 Start-up FDNA-01 configuration parameters group C (group 3) Note: The actual parameter group number depends on the drive type. Group C (group 3) corresponds to: parameter group 54 in ACS355 parameter group 52 in ACSM1, ACS380, ACH580, ACQ580, ACS580, ACS850 and ACQ810 parameter group 52 in ACS880 if the adapter is installed as fieldbus adapter A or group 55 if the adapter is installed as fieldbus adapter B. No. 1) Name/Value Description Default 01 FBA data in1 (drive to master) In input assembly instances that include drive parameters, this parameter specifies which parameter s value is placed in location DATA IN 1 value sent by the drive to the DeviceNet network. Content is defined by a decimal number in the range of 0 to 9999 as follows: Note: The FDNA-01 configuration parameters are 16-bit parameters. If the mapped parameter is a 32-bit parameter, it automatically reserves two consecutive parameters. For example, mapping a 32-bit parameter to parameter no. 1 also reserves parameter no Not used Parameter index with format xxyy, where xx is the parameter group number (1 99) and yy is the parameter number index within that group (01 99). DATA IN 2 DATA IN 10 0 Not used 1 99 Virtual address area of drive control. Not used with the FDNA-01 module. 101 Parameter area of the drive 9999 See parameter FBA data in1. 0 1) The number of parameters in this group may vary by drive type and drive firmware. 0

47 Start-up 47 Control locations ABB drives can receive control information from multiple sources including digital inputs, analog inputs, the drive control panel and a communication module (for example, the adapter module). ABB drives allow the user to separately determine the source for each type of control information (Start, Stop, Direction, Reference, Fault Reset, and so on). To give the fieldbus master station the most complete control over the drive, the communication module must be selected as the source for this information. The parameter setting examples below contain the drive control parameters needed in the examples. For a complete parameter list, see the drive documentation. Starting up ACS355 drives 1. Power up the drive. 2. Enable the communication between the adapter module and the drive by setting parameter 9802 COMM PROT SEL to EXT FBA. 3. Set the FDNA-01 configuration parameters in parameter group 51. At the minimum, set the required number in parameter 5102 MAC ID and the required baud rate in 5103 BAUD RATE. In addition, select the communication profile in 5104 DRIVE PROFILE. With the ODVA AC/DC drive profile select the way in which the motor is stopped in 5105 ODVA STOP FUNC. 4. Define the process data transferred to and from the drive in FDNA-01 parameter groups 54 and 55. Note: If communication between the FDNA-01 and DeviceNet master is established, changes to the configuration parameters can be done also through Fieldbus configuration object 91h. 5. Validate the settings made in parameter group 51 by setting parameter 5127 FBA PAR REFRESH to REFRESH.

48 48 Start-up 6. Set the relevant drive control parameters to control the drive according to the application. Examples of appropriate values are shown in the tables below. Parameter setting examples ACS355 ABB Drives profile This example shows how to configure the ACS355 drive to use the ABB Drives profile with set speed and set torque plus drive parameters assembly. The used I/O assembly instances are 902 and 952. The table below gives the recommended drive parameter settings. Drive parameter Setting for Description ACS355 drives 9802 COMM PROT SEL 4 = EXT FBA Enables communication between drive and adapter module FBA TYPE DEVICENET 1) Displays the type of the adapter module FB PAR 2 (MAC ID) 5103 FB PAR 3 (BAUD RATE) 5104 FB PAR 4 (DRIVE PROFILE) 5105 FB PAR 5 (ODVA STOP FUNC) 5106 FB PAR 6 (OUTPUT INSTANCE) 5107 FB PAR 7 (OUTPUT NUM PARS) 5108 FB PAR 8 (INPUT INSTANCE) 2 Defines the MAC ID number of the adapter module. 0 (= 125 kbit/s) Sets the baud rate for the DeviceNet interface. 0 (= DCU Profile) Selects the profile used in the communication between drive and adapter module. 0 (= Ramp) Motor decelerates along the active deceleration ramp. 902 Selects the ABB Drives profile with speed and torque plus drive parameters output instance. 10 Must always be set to 10, except as provided in Appendix A Varying the number of drive parameters. 952 Selects the ABB Drives profile with speed and torque plus drive parameters input instance.

49 Start-up 49 Drive parameter 5109 FB PAR 9 (INPUT NUM PARS) 5110 FB PAR 10 (ODVA SPEED SCALE) 5111 FB PAR 11 (ODVA TORQUE SCALE) Setting for ACS355 drives Description 10 Must always be set to 10, except as provided in Appendix A Varying the number of drive parameters. 128 Sets the scaling as 1 rpm for the ODVA speed reference. 128 Sets the scaling as 1 Nm for the ODVA torque reference FBA DATA IN Current 5402 FBA DATA IN DC bus voltage 5403 FB DATA IN DATA IN FBA DATA OUT Acceleration time FBA DATA OUT Deceleration time FB DATA OUT DATA OUT FBA PAR REFRESH 1 = REFRESH Validates the FDNA-01 configuration parameter settings EXT1 COMMANDS 10 = COMM Selects the fieldbus interface as the source of the start and stop commands for external control location DIRECTION 3 = REQUEST Allows control of rotation direction REF1 SELECT 8 = COMM Selects the fieldbus reference 1 as the source for speed reference FAULT RESET SEL 8 = COMM Selects the fieldbus interface as the source for the fault reset signal MOTOR CTRL MODE 2 = VECTOR: TORQ Selects the vector control mode as the motor control mode EXT2 COMMANDS 10 = COMM Selects the fieldbus interface as the source of the start and stop commands for external control location EXT1/EXT2 SEL 8 = COMM Enables external control location 1/2 selection through the fieldbus REF2 SELECT 8 = COMM Selects the fieldbus reference 2 as the source for torque reference.

50 50 Start-up Drive parameter Setting for Description ACS355 drives 1601 RUN ENABLE 7 = COMM Selects the fieldbus interface as the source for the inverted Run enable signal (Run disable). 1) Read-only or automatically detected/set The start sequence for the parameter example above is given below. Control word: 47Eh (1150 decimal) READY TO SWITCH ON 47Fh (1151 decimal) OPERATING (Speed mode) or C7Fh (3199 decimal) OPERATING (Torque mode). ODVA AC/DC drive profile The following example shows how to configure the ACS355 drive to use the Extended speed and torque control assembly of the ODVA AC/DC drive profile. The used I/O assembly instances are 23 and 73. The table below gives the recommended drive parameter settings. Drive parameter Setting for Description ACS355 drives 9802 COMM PROT SEL 4 = EXT FBA Enables communication between drive and adapter module FBA TYPE DEVICENET 1) Displays the type of the adapter module FB PAR 2 (MAC ID) 5103 FB PAR 3 (BAUD RATE) 5104 FB PAR 4 (DRIVE PROFILE) 5105 FB PAR 5 (ODVA STOP FUNC) 5 Defines the MAC ID number of the adapter module. 0 (= 125 kbit/s) Sets the baud rate for the DeviceNet interface. 0 (= DCU Profile) Selects the profile used in the communication between drive and adapter module. 0 (= Ramp) Motor decelerates along the active deceleration ramp.

51 Start-up 51 Drive parameter 5106 FB PAR 6 (OUTPUT INSTANCE) 5108 FB PAR 8 (INPUT INSTANCE) 5110 FB PAR 10 (ODVA SPEED SCALE) 5111 FB PAR 11 (ODVA TORQUE SCALE) Setting for ACS355 drives Description 23 Selects the ODVA extended speed and torque control output instance. 73 Selects the ODVA extended speed and torque control input instance. 128 Sets the scaling as 1 rpm for the ODVA speed reference. 128 Sets the scaling as 1 Nm for the ODVA torque reference FBA PAR REFRESH 1 = REFRESH Validates the FDNA-01 configuration parameter settings EXT1 COMMANDS 10 = COMM Selects the fieldbus interface as the source of the start and stop commands for external control location DIRECTION 3 = REQUEST Allows control of rotation direction REF1 SELECT 8 = COMM Selects the fieldbus reference 1 as the source for speed reference FAULT RESET SEL 8 = COMM Selects the fieldbus interface as the source for the fault reset signal MOTOR CTRL MODE 2 = VECTOR: TORQ Selects the vector control mode as the motor control mode EXT2 COMMANDS 10 = COMM Selects the fieldbus interface as the source of the start and stop commands for external control location EXT1/EXT2 SEL 1 = DI1 Selects digital input DI1 as the source for the external control location EXT1/EXT2 selection REF2 SELECT 8 = COMM Selects the fieldbus reference 2 as the source for torque reference RUN ENABLE 7 = COMM Selects the fieldbus interface as the source for the inverted Run enable signal (Run disable). 1) Read-only or automatically detected/set

52 52 Start-up Note: In this example, digital input DI1 has been configured to control whether to use the speed or torque control mode. The start sequence for the parameter example above is given below. Control word: 0h (0 decimal) READY 1h (1 decimal) ENABLED (Running forward) 2h (2 decimal) ENABLED (Running reverse) Starting up ACSM1 drives 1. Power up the drive. 2. Enable the communication between the adapter module and the drive by setting parameter FBA ENABLE to Enable. 3. Ensure that FBA REF1 MODESEL is set to Speed and FBA REF2 MODESEL is set to Torque. 4. Set the FDNA-01 configuration parameters in parameter group Define the process data transferred to and from the drive in FDNA-01 parameter groups 52 and 53. Note: If communication between the FDNA-01 and DeviceNet master is established, changes to the configuration parameters can be done also through Fieldbus configuration object 91h. 6. Validate the settings made in parameter groups 51, 52 and 53 by setting parameter FBA PAR REFRESH to REFRESH. 7. Set the relevant drive control parameters to control the drive according to the application. Examples of appropriate values are shown in the tables below.

53 Start-up 53 Parameter setting examples ACSM1 ABB Drives profile The following example shows how to configure the ACSM1 drive to use the ABB Drives profile. The used I/O assembly instances are 902 and 952. The table below gives the recommended drive parameter settings. Drive parameter Setting for Description ACSM1 drives FBA ENABLE 1 = Enable Enables communication between drive and adapter module FBA REF1 MODESEL FBA REF2 MODESEL Speed Torque Selects speed as the adapter module REF1 type. Selects torque as the adapter module REF2 type FBA TYPE DEVICENET 1) Displays the type of the adapter module FBA PAR2 (MAC ID) FBA PAR3 (BAUD RATE) FBA PAR6 (OUTPUT INSTANCE) FBA PAR7 (OUTPUT NUM PARS) FBA PAR8 (INPUT INSTANCE) FBA PAR9 (INPUT NUM PARS) 6 Defines the MAC ID number of the adapter module. 0 (= 125 kbit/s) Sets the baud rate for the DeviceNet interface. 902 Selects the ABB Drives profile with speed and torque plus drive parameters output instance. 10 Must always be set to 10, except as provided in Appendix A Varying the number of drive parameters. 952 Selects the ABB Drives profile with speed and torque plus drive parameters input instance. 10 Must always be set to 10, except as provided in Appendix A Varying the number of drive parameters FBA DATA IN1 117 Motor temp FBA DATA IN2 104 Motor current - MSW FBA DATA IN3 0 Motor current - LSW FBA DATA IN4 107 DC voltage - MSW

54 54 Start-up Drive parameter Setting for ACSM1 drives FBA DATA IN5 0 DC voltage - LSW FBA DATA IN6 108 Encoder 1 speed - MSW FBA DATA IN7 0 Encoder 1 speed - LSW FBA DATA IN FBA DATA IN FBA DATA OUT Acceleration time - MSW FBA DATA OUT2 0 Acceleration time - LSW FBA DATA OUT Deceleration time - MSW FBA DATA OUT4 0 Deceleration time - LSW FBA DATA OUT Constant speed FBA DATA OUT Speed ref jog FBA DATA OUT Speed ref jog FBA DATA OUT FBA DATA OUT FBA PAR REFRESH 1 = REFRESH Validates the FDNA-01 configuration parameter settings EXT1 START FUNC 3 = FBA Selects the fieldbus interface as the source of the start and stop commands for external control location EXT2 START FUNC 3 = FBA Selects the fieldbus interface as the source of the start and stop commands for external control location SPEED REF1 SEL 3 = FBA REF1 Selects the fieldbus reference 1 as the source for speed reference TORQ REF1 SEL 4 = FBA REF2 Selects the fieldbus reference 2 as the source for torque reference EXT1 MODE 1/2SEL P = P.FBA MAIN CW.15 Description Selects FBA Control word bit 15 as the source for the external control location EXT1/EXT2 selection EXT1 CTRL MODE1 1 = Speed Selects speed as the control mode for external control location EXT2 CTRL MODE1 2 =Torque Selects torque as the control mode for external control location 2.

55 Start-up 55 Drive parameter MOTOR CTRL MODE Setting for ACSM1 drives 1) Read-only or automatically detected/set Description 0 = DTC Selects DTC as the motor control mode. The start sequence for the parameter example above is given below. Control word: 47Eh (1150 decimal) READY TO SWITCH ON 47Fh (1151 decimal) OPERATING (Speed mode) or C7Fh (3199 decimal) OPERATING (Torque mode). ODVA AC/DC drive profile The following example shows how to configure the ACSM1 drive to use the ODVA AC/DC drive profile. The used I/O assembly instances are 23 and 73. The table below gives the recommended drive parameter settings. Drive parameter Setting for Description ACSM1 drives FBA ENABLE 1 = Enable Enables communication between drive and adapter module FBA REF1 MODESEL FBA REF2 MODESEL Speed Torque Selects speed as the adapter module REF1 type. Selects torque as the adapter module REF2 type FBA TYPE DEVICENET 1 Displays the type of the adapter module FBA PAR2 (MAC ID) FBA PAR3 (BAUD RATE) FBA PAR6 (OUTPUT INSTANCE) 5 Defines the MAC ID number of the adapter module. 0 (= 125 kbit/s) Sets the baud rate for the DeviceNet interface. 23 Selects the ODVA extended speed and torque control output instance.

56 56 Start-up Drive parameter FBA PAR8 (INPUT INSTANCE) Setting for ACSM1 drives Description 73 Selects the ODVA extended speed and torque control input instance FBA PAR REFRESH 1 = REFRESH Validates the FDNA-01 configuration parameter settings EXT1 START FUNC 3 = FBA Selects the fieldbus interface as the source of the start and stop commands for external control location EXT2 START FUNC 3 = FBA Selects the fieldbus interface as the source of the start and stop commands for external control location SPEED REF1 SEL 3 = FBA REF1 Selects the fieldbus reference 1 as the source for speed reference TORQ REF1 SEL 4 = FBA REF2 Selects the fieldbus reference 2 as the source for torque reference EXT1/EXT2 SEL P = PI.DI STATUS.0 Selects digital input DI1 as the source for the external control location EXT1/EXT2 selection EXT1 CTRL MODE1 1 = Speed Selects speed as the control mode for external control location EXT2 CTRL MODE1 2 =Torque Selects torque as the control mode for external control location MOTOR CTRL MODE 1) Read-only or automatically detected/set 0 = DTC Selects DTC as the motor control mode. Note: In this example, digital input DI1 has been configured to control whether to use the speed or torque control mode. The start sequence for the parameter example above is given below. Control word: 0h (0 decimal) READY 1h (1 decimal) ENABLED (Running forward) 2h (2 decimal) ENABLED (Running reverse)

57 Start-up 57 Starting up ACS850 and ACQ810 drives 1. Power up the drive. 2. Enable the communication between the adapter module and the drive by setting parameter Fba enable to Enable. 3. Ensure that Fb ref1 modesel is set to Speed (both ACS850 and ACQ810) and Fb ref2 modesel is set to Torque (only ACS850). 4. Set the FDNA-01 configuration parameters in drive parameter group Define the process data transferred to and from the drive in FDNA-01 parameter groups 52 and 53. Note: If communication between the FDNA-01 and DeviceNet master is established, changes to the configuration parameters can be done also through Fieldbus configuration object 91h. 6. Validate the settings made in parameter groups 51, 52 and 53 by setting parameter FBA par refresh to Refresh. 7. Set the relevant drive control parameters to control the drive according to the application. Examples of appropriate values are shown in the tables below.

58 58 Start-up Parameter setting examples ACS850 and ACQ810 ABB Drives profile The following example shows how to configure the ACS850 or ACQ810 drive to use the ABB Drives profile. The used I/O assembly instances are 902 and 952. The table below gives the recommended drive parameter settings. Drive parameter Setting for ACS850/ACQ810 drives Description Fba enable 1 = Enable Enables communication between drive and adapter module Fb ref1 modesel Speed Selects speed as the adapter module ref1 type Fb ref2 modesel Torque Selects torque as the adapter module ref2 type (only with ACS850) Fba type DEVICENET 1) Displays the type of the adapter module FBA par2 (MAC ID) FBA par3 (BAUD RATE) FBA par6 (OUTPUT INSTANCE) FBA par7 (OUTPUT NUM PARS) FBA par8 (INPUT INSTANCE) FBA par9 (INPUT NUM PARS) 5 Defines the MAC ID number of the adapter module. 0 (= 125 kbit/s) Sets the baud rate for the DeviceNet interface. 902 Selects the ABB Drives profile with speed and torque plus drive parameters output instance. 10 Must always be set to 10, except as provided in Appendix A Varying the number of drive parameters. 952 Selects the ABB Drives profile with speed and torque plus drive parameters input instance. 10 Must always be set to 10, except as provided in Appendix A Varying the number of drive parameters FBA data in1 123 Motor power FBA data in2 0 Motor power - LSW

59 Start-up 59 Drive parameter Setting for ACS850/ACQ810 drives FBA data in3 105 Motor current percent FBA data in4 107 DC voltage FBA data in5 0 DC voltage - LSW FBA data in6 108 Encoder1 speed FBA data in7 0 Encoder 1 speed - LSW FBA data in FBA data in FBA data out Acc time FBA data out2 0 Acceleration time 2 - LSW FBA data out Dec time FBA data out4 0 Deceleration time 2 - LSW FBA data out Const speed FBA data out Const speed FBA data out Const speed FBA data out FBA data out FBA par refresh 1 = Refresh Validates the FDNA-01 configuration parameter settings Ext1 start func FB Selects the fieldbus interface as the source of the start and stop commands for external control location Ext2 Start func 3 = FB Selects the fieldbus as the source for start and stop commands for external control location EXT2 (only with ACS850) Ext1/Ext sel P = P.FBA main cw.15 Description Selects FBA Control word bit 15 as the source for external control location EXT1/EXT2 selection (only with ACS850) Ext1 ctrl mode 1 = Speed Selects speed as the operating mode for external control location EXT1.

60 60 Start-up Drive parameter Setting for Description ACS850/ACQ810 drives Ext2 ctrl mode 2 = Torque Selects torque as the operating mode for external control location EXT2 (only with ACS850) Menu set sel (ACS850) Menu selection (ACQ810) 2 = Load long (ACS850) 2 = Full (ACQ810) Load long parameter list. All parameters will be displayed Speed ref1 sel FB Selects the fieldbus reference 1 as the source for speed reference Torq ref1 sel FBA ref2 Selects fieldbus reference 2 as the source of the torque reference 1 (only with ACS850). 1) Read-only or automatically detected/set The start sequence for the parameter example above is given below. Control word: 47Eh (1150 decimal) READY TO SWITCH ON 47Fh (1151 decimal) OPERATING (Speed mode) or C7Fh (3199 decimal) OPERATING (Torque mode in ACS850).

61 Start-up 61 ODVA AC/DC drive profile The following example shows how to configure the ACS850 or ACQ810 drive to use the ODVA AC/DC drive profile. The used I/O assembly instances are 23 and 73. The table below gives the recommended drive parameter settings. Drive parameter Setting for ACS850/ACQ810 drives Description Fba enable 1 = Enable Enables communication between drive and adapter module Fb ref1 modesel Speed Selects speed as the adapter module ref1 type Fb ref2 modesel Torque Selects torque as the adapter module ref2 type (only with ACS850) FBA type DEVICENET 1) Displays the type of the adapter module FBA par2 (MAC ID) FBA par3 (BAUD RATE) FBA par6 (OUTPUT INSTANCE) FBA par8 (INPUT INSTANCE) 5 Defines the MAC ID number of the adapter module. 0 (= 125 kbit/s) Sets the baud rate for the DeviceNet interface. 23 Selects the ODVA AC/DC drive profile output instance. 73 Selects the ODVA AC/DC profile input instance FBA par refresh 1 = Refresh Validates the FDNA-01 configuration parameter settings Ext1 start func 3 = FB Selects the fieldbus interface as the source of the start and stop commands for external control location Ext2 Start func 3 = FB Selects the fieldbus as the source for start and stop commands for external control location EXT2 (only with ACS850).

62 62 Start-up Drive parameter Ext1/Ext2 sel DI1 Selects digital input DI1 as the source for external control location EXT1/EXT2 selection (only with ACS850) Ext2 ctrl mode 2 = Torque Selects torque as the operating mode for external control location EXT2 (only with ACS850) Menu set sel (ACS850) Menu selection (ACQ810) Setting for ACS850/ACQ810 drives 2 = Load long (ACS850) 1 = Full (ACQ810) Description Load long parameter list. All parameters will be displayed Speed ref1 sel FBA ref1 Selects the fieldbus reference 1 as the source for speed reference Torq ref1 sel FBA ref2 Selects fieldbus reference 2 as the source of the torque reference 1 (only with ACS850). 1) Read-only or automatically detected/set Note: For ACS850 in this example, digital input DI1 has been configured to control whether to use the speed or torque control mode. The start sequence for the parameter example above is given below. Control word: 0h (0 decimal) READY 1h (1 decimal) ENABLED (Running forward) 2h (2 decimal) ENABLED (Running reverse)

63 Start-up 63 Starting up ACS880, ACS580, ACQ580, ACH580, ACS580 drives This example sets up the fieldbus adapter installed as fieldbus adapter A. To set up the fieldbus adapter B, perform the same tasks with the corresponding parameters in parameter groups 50, 54, 55, and Power up the drive. 2. Enable the communication between the adapter module and the drive by selecting the correct slot number in parameter FBA A enable. The selection must correspond to the slot where the adapter module is installed. For example, if the adapter module is installed in slot 1, you must select slot Ensure that parameter FBA A ref1 type is set to Speed and parameter FBA A ref2 type is set to Torque. 4. Set the FDNA-01 configuration parameters in drive parameter group Define the process data transferred to and from the drive in FDNA-01 parameter groups 52 and 53. Note: If communication between the FDNA-01 and DeviceNet master is established, changes to the configuration parameters can be done also through Fieldbus configuration object 91h. 6. Validate the settings made in parameter groups 51, 52 and 53 by setting parameter FBA par refresh to Refresh. 7. Set the relevant drive control parameters to control the drive according to the application. Examples of appropriate values are shown in the tables below. Parameter setting examples ACS880 ABB Drives profile The following example shows how to configure the ACS880 drive to use the ABB Drives profile.

64 64 Start-up The used I/O assembly instances are 902 and 952. The table below gives the recommended drive parameter settings. Drive parameter Setting for Description ACS880 drives FBA A enable 1 = Enable Enables communication between drive and adapter module FBA A ref1 type 4 = Speed Selects speed as the fieldbus A reference 1 type FBA A ref2 type 3 = Torque Selects torque as the fieldbus A reference 2 type FBA type DeviceNet 1) Displays the type of the adapter module MAC ID 6 Defines the MAC ID number of the adapter module Baud rate 0 = 125kbit/s Sets the baud rate for the DeviceNet interface Output instance 902 Selects the ABB Drives profile with speed and torque plus drive parameters output instance Output num pars 10 Must always be set to 10. For exceptions, see Appendix A Varying the number of drive parameters FBA data in1 1.7 Motor current - MSW FBA data in2 0 = None Motor current - LSW FBA data in DC voltage - MSW FBA data in4 0 = None DC voltage - LSW FBA data in5 0 = None FBA data in FBA data out Acceleration time - MSW FBA data out2 0 = None Acceleration time - LSW FBA data out Deceleration time - MSW FBA data out4 0 = None Deceleration time - LSW FBA data out FBA data out10 0 = None

65 Start-up 65 Drive parameter FBA par refresh 1 = Configure Validates the FDNA-01 configuration parameter settings Ext1/Ext2 selection 2 = MCW bit11: Ext ctrl Ext1 control mode 1 2 = MCW bit11: Ext ctrl loc Selects FBA Control word bit 11 as the source for the external control location EXT1/EXT2 selection. Selects speed control as the control mode 1 for external control location EXT Ext2 control mode 1 3 = Torque Selects torque control as the control mode 1 for external control location EXT Ext1 commands 12 = Fieldbus A Selects fieldbus interface A as the source of the start and stop commands for external control location EXT Ext2 commands 12 = Fieldbus A Selects fieldbus interface A as the source of the start and stop commands for external control location EXT Speed ref1 selection Torque ref1 selection Setting for ACS880 drives 1) Read-only or automatically detected/set 2) Example Description 4 = FB A ref1 Selects fieldbus A reference 1 as the source for speed reference 1. 5 = FB A ref2 Selects fieldbus reference 2 as the source for torque reference 1. The start sequence for the parameter example above is given below. Control word: 47Eh (1150 decimal) READY TO SWITCH ON 47Fh (1151 decimal) OPERATING (Speed mode) or C7Fh (3199 decimal) OPERATING (Torque mode) ODVA AC/DC drive profile The following example shows how to configure the ACS880 drive to use the ODVA AC/DC drive profile.

66 66 Start-up The used I/O assembly instances are 23 and 73. The table below gives the recommended drive parameter settings. Drive parameter Setting for Description ACS880 drives FBA A enable 1 = Enable Enables communication between drive and adapter module FBA A ref1 type 4 = Speed Selects Speed as the fieldbus A reference 1 type FBA A ref2 type 3 = Torque Selects Torque as the fieldbus A reference 2 type FBA type DeviceNet 1) Displays the type of the adapter module MAC ID 6 Defines the MAC ID number of the adapter module Baud rate 0 = 125kbit/s Sets the baud rate for the DeviceNet interface Output instance 23 Selects the ABB Drives profile with speed and torque plus drive parameters output instance Output num pars 10 Must always be set to 10. For exceptions, see Appendix A Varying the number of drive parameters FBA par refresh 1 = Configure Validates the FDNA-01 configuration parameter settings Ext1/Ext2 selection 3 = DI1 Selects digital input DI1 as the source for the external control location EXT1/EXT2selection Ext1 control mode 1 2 = Speed Selects speed control as the control mode 1 for external control location EXT Ext2 control mode 1 3 = Torque Selects torque control as the control mode 1 for external control location EXT Ext1 commands 12 = Fieldbus A Selects fieldbus interface A as the source of the start and stop commands for external control location EXT1.

67 Start-up 67 Drive parameter Ext2 commands 12 = Fieldbus A Selects fieldbus interface A as the source of the start and stop commands for external control location EXT Speed ref1 selection Torque ref1 selection Setting for ACS880 drives 1) Read-only or automatically detected/set 2) Example Description 4 = FB A ref1 Selects fieldbus A reference 1 as the source for speed reference 1. 5 = FB A ref2 Selects fieldbus reference 2 as the source for torque reference 1. Note: In this example, digital input DI1 has been configured to control whether to use the speed or torque control mode. The start sequence for the parameter example above is given below. Control word: 0h (0 decimal) READY 1h (1 decimal) ENABLED (Running forward) 2h (2 decimal) ENABLED (Running reverse)

68 68 Start-up Configuring the master station After the adapter module has been initialized by the drive, the master station must be prepared for communication with the module. An example of an Allen-Bradley PLC is given below. If you are using another master system, refer to its documentation for more information. The example can be applied to all drive types compatible with the module. EDS files The Electronic Data Sheet (EDS) files specify the properties of the device for the DeviceNet scanner. The DeviceNet scanner identifies the device by means of the product code, device type, and major revision attributes. For more information, see Identity object, class 01h on page 132. To enable the use of different ABB drive types on the same DeviceNet network, a unique product code has been given to each drive type and application combination. EDS files are available from the Document library ( Note: Only one EDS file with the same DeviceNet product code can be installed in the PLC at a time.

69 Start-up 69 Configuring an Allen-Bradley PLC This example shows how to set up an Allen-Bradley CompactLogix PLC with a 1769-SDN DeviceNet Scanner to use a drive equipped with a FDNA-01 fieldbus adapter, using RSNetWorx and RSLogix 5000 to configure and control the network. Slight vendor-specific differences may exist when using other programs or master devices. In this example, ACS880 is used as the drive. 1. Select and import the EDS file for the drive. For example, ACS880_FDNA01_v2.23_eu.EDS. For more help on choosing the correct file, refer to ABB EDS Selection Guide delivered with the EDS files. Note: Only one EDS file with the same Product ID can be installed in the PLC at a time. 2. Add a drive to the network in RSNetWorx for DeviceNet.

70 70 Start-up 3. Configure the device MAC address.

71 Start-up Configure the DeviceNet Scanner. Add the drive to Scanlist and edit I/O parameters. Select Polled or Change of State/Cyclic. Then enter the input and output sizes of the I/O assemblies that are used (for example, for Basic Speed Control Assemblies 20 and 70, each size is set to 4 bytes.).

72 72 Start-up 5. For convenience, you can also edit the Input and Output memory mappings. By default, the two 16-bit input words are mapped into a single 32-bit double word. It is more convenient to map them into separate double words. Output words can be mapped similarly. 6. Download the scanner settings to the device in the online mode.

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FSCA-01 RS-485 adapter module User s manual List of related manuals See section Related manuals on page 13. You can find manuals and other product documents

More information

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FEPL-02 Ethernet POWERLINK adapter module User s manual

OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FEPL-02 Ethernet POWERLINK adapter module User s manual OPTION FOR ABB DRIVES, CONVERTERS AND INVERTERS FEPL-02 Ethernet POWERLINK adapter module User s manual List of related manuals See section Related manuals on page 15. You can find manuals and other product

More information

- Alii -,..., ~~~~~~~~'-~" ..., ,..- ))) --t ..., )(1. User s manual FEPL-02 Ethernet POWERLINK adapter module. IIIIIJ!ll"

- Alii -,..., ~~~~~~~~'-~ ..., ,..- ))) --t ..., )(1. User s manual FEPL-02 Ethernet POWERLINK adapter module. IIIIIJ!ll Options for ABB drives, converters and inverters User s manual FEPL-02 Ethernet POWERLINK adapter module,..- ))) --t - Alii - -,...,..., IIIIIJ!ll"...,,, FEPL ~ 02,.., " ETHERNET powerljnk ADApTER _,,""

More information

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01 ABB Drives User s Manual DeviceNet Adapter Module RDNA-01 DeviceNet Adapter Module RDNA-01 User s Manual 3AFE64504223 Rev D EN EFFECTIVE: 16.07.2007 2007 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01

ABB Drives. User s Manual DeviceNet Adapter Module RDNA-01 ABB Drives User s Manual DeviceNet Adapter Module RDNA-01 DeviceNet Adapter Module RDNA-01 User s Manual 3AFE64504223 REV C EN EFFECTIVE: 16.11.2006 2006 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Options for ABB drives, converters and inverters. User s manual FECA-01 EtherCAT adapter module

Options for ABB drives, converters and inverters. User s manual FECA-01 EtherCAT adapter module Options for ABB drives, converters and inverters User s manual FECA-01 EtherCAT adapter module List of related manuals Drive manuals and guides Code (EN/Multilingual) ACS355 drives (0.37 22 kw, 0.5 30

More information

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor Start-up Guide DeviceNet Adapter Module NDNA-02

efesotomasyon.com - Control Techniques,emerson,saftronics -ac drive-servo motor Start-up Guide DeviceNet Adapter Module NDNA-02 ABB Drives Installation and Start-up Guide DeviceNet Adapter Module NDNA-02 DeviceNet Adapter Module NDNA-02 Installation and Start-up Guide 3AFY 58919829 R0325 REV B EFFECTIVE: 1.10.2001 2001 ABB Industry

More information

Options for ABB drives, converters and inverters. User s manual FECA-01 EtherCAT adapter module

Options for ABB drives, converters and inverters. User s manual FECA-01 EtherCAT adapter module Options for ABB drives, converters and inverters User s manual FECA-01 EtherCAT adapter module List of related manuals See section Related manuals on page 16. EtherCAT is registered trademark and patented

More information

Options for ABB drives. User s manual FSE-31 pulse encoder interface module

Options for ABB drives. User s manual FSE-31 pulse encoder interface module Options for ABB drives User s manual FSE-31 pulse encoder interface module List of related manuals and guides Drive hardware manuals Code (EN) ACS880-01 hardware manual 3AUA0000078093 ACS880-04 hardware

More information

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module

Options for ABB drives, converters and inverters. User s manual FDIO-01 digital I/O extension module Options for ABB drives, converters and inverters User s manual FDIO-01 digital I/O extension module List of related manuals Drive manuals and guides ACS880-01 manuals ACS880-04 manuals ACS880-07 manuals

More information

Start-up Guide DeviceNet Adapter Module CFB-DEV

Start-up Guide DeviceNet Adapter Module CFB-DEV ACS 160 Installation and Start-up Guide DeviceNet Adapter Module CFB-DEV DeviceNet Adapter Module CFB-DEV Installation and Start-up Guide 3BFE 64401882 REV B EFFECTIVE: 1.11.2002 2002 ABB Oy. All Rights

More information

ABB drives. User s manual MACRO adapter module FMAC-01

ABB drives. User s manual MACRO adapter module FMAC-01 ABB drives User s manual MACRO adapter module FMAC-01 List of related manuals Drive hardware manuals and guides ACSM1-04 drive modules (0.75 to 45 kw) hardware manual ACSM1-04 drive modules (55 to 110

More information

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual Modbus Adapter Module FMBA-01 ABB Drives User s Manual Modbus Adapter Module FMBA-01 Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01 ABB Drives User s Manual Modbus Adapter Module RMBA-01 Modbus Adapter Module RMBA-01 User s Manual 3AFE 64498851 REV A EN EFFECTIVE: 1.3.2002 2002 ABB Oy. All Rights Reserved. Safety instructions Overview

More information

Options for ABB drives, converters and inverters. User s manual FEA-03 F-series extension adapter

Options for ABB drives, converters and inverters. User s manual FEA-03 F-series extension adapter Options for ABB drives, converters and inverters User s manual FEA-03 F-series extension adapter List of related manuals Option manuals and guides FEA-03 F-series extension adapter user s manual FDCO-01/02

More information

ABB low voltage drives. Supplement External control unit (+P906) for ACH580-04, ACQ and ACS drives

ABB low voltage drives. Supplement External control unit (+P906) for ACH580-04, ACQ and ACS drives ABB low voltage drives Supplement External control unit (+P906) for ACH580-04, ACQ580-04 and ACS580-04 drives List of related manuals Drive hardware manuals and guides External control unit (+P906) for

More information

ABB industrial drives. Supplement ACS880 distributed I/O bus

ABB industrial drives. Supplement ACS880 distributed I/O bus ABB industrial drives Supplement ACS880 distributed I/O bus List of related manuals General manuals Safety instructions for ACS880 multidrive cabinets and modules Safety instructions for ACS880 liquid-cooled

More information

DeviceNet Expansion Board

DeviceNet Expansion Board DeviceNet Expansion Board Catalog No. EXBD05 Installation and Operating Manual 10/02 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................

More information

FC 300 DeviceNet and Allen Bradley Control logix 5550

FC 300 DeviceNet and Allen Bradley Control logix 5550 Introduction... 2 FC 300 DeviceNet card... 2 Creation of an EDS file... 4 Configuring the FC 300 with RS Networx... 7 I/O communication with RS Logix 5000... 1 0 Explicit messages with RS Logix 5000...

More information

Motors I Automation I Energy I Transmission & Distribution I Coatings. DeviceNet CFW700. User s Manual

Motors I Automation I Energy I Transmission & Distribution I Coatings. DeviceNet CFW700. User s Manual Motors I Automation I Energy I Transmission & Distribution I Coatings DeviceNet CFW700 User s Manual DeviceNet User s Manual Series: CFW700 Language: English Document Number: 10001114309 / 00 Publication

More information

DeviceNet CFW500. User s Manual. Phone: Fax: Web: -

DeviceNet CFW500. User s Manual. Phone: Fax: Web:  - DeviceNet CFW500 User s Manual DeviceNet User s Manual Series: CFW500 Language: English Document Number: 10002253313 / 00 Publication Date: 05/2013 CONTENTS CONTENTS... 3 ABOUT THIS MANUAL... 5 ABBREVIATIONS

More information

User s Manual Pulse Encoder Interface Module OTAC-01

User s Manual Pulse Encoder Interface Module OTAC-01 Drive IT Low Voltage AC Drives User s Manual Pulse Encoder Interface Module OTAC-01 2 Safety WARNING! All electrical installation and maintenance work on the drive should be carried out by qualified electricians

More information

User Manual FRN 1.xx 2.xx

User Manual FRN 1.xx 2.xx Allen-Bradley Bulletin 160 DeviceNet Communication Module User Manual FRN 1.xx 2.xx Important User Information Because of the variety of uses for the products described in this publication, those responsible

More information

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice

MPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths

More information

ABB Drives. User s Manual ControlNet Adapter Module RCNA-01

ABB Drives. User s Manual ControlNet Adapter Module RCNA-01 ABB Drives User s Manual ControlNet Adapter Module RCNA-01 ControlNet Adapter Module RCNA-01 User s Manual 3AFE64506005 Rev B EN EFFECTIVE: 21.10.2008 2008 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01

ABB Drives. User s Manual Pulse Encoder Interface Module MTAC-01 ABB Drives User s Manual Pulse Encoder Interface Module MTAC-01 Pulse Encoder Interface Module MTAC-01 User s Manual 3AFE68591091 REV B EN EFFECTIVE: 04.04.2006 2006 ABB Oy. All Rights Reserved. 5 Safety

More information

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01

ABB Drives. User s Manual. Analogue I/O Extension Module RAIO-01 ABB Drives User s Manual Analogue I/O Extension Module RAIO-01 Analogue I/O Extension Module RAIO-01 User s Manual 3AFE 64484567 REV A EN EFFECTIVE: 1.2.2002 2002 ABB Oy. All Rights Reserved. Safety

More information

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1

Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1 YASKAWA Varispeed SERIES OPTION CARD DeviceNet COMMUNICATION INTERFACE CARD USER'S MANUAL Model: SI-N1 YASKAWA MANUAL NO. SIBP C730600 01B Copyright 2004 YASKAWA ELECTRIC CORPORATION All rights reserved.

More information

MPCR Series DeviceNet Technical Manual

MPCR Series DeviceNet Technical Manual MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as

More information

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block

USER S MANUAL. FX2N-64DNET DeviceNet Interface Block USER S MANUAL FX2N-64DNET DeviceNet Interface Block FX2N-64DNET DeviceNet Interface Block Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation

More information

2002 Series DeviceNet Technical Manual

2002 Series DeviceNet Technical Manual 2002 Series DeviceNet Technical Manual Table of Contents 2002 Series DeviceNet Technical Manual 2002 Introduction...4 Product Overview...4 About DeviceNet...5 Overview...5 2002 DeviceNet Features...5 Cabling

More information

ABB industrial drives. EMC filter and ground-to-phase varistor disconnecting instructions ACS880 frames R1 to R11

ABB industrial drives. EMC filter and ground-to-phase varistor disconnecting instructions ACS880 frames R1 to R11 ABB industrial drives EMC filter and ground-to-phase varistor disconnecting instructions ACS880 frames R1 to R11 List of related manuals hardware manuals and guides Code (English) EMC filter and ground-to-phase

More information

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01

ABB Drives. User s Manual. Digital I/O Extension Module RDIO-01 ABB Drives User s Manual Digital I/O Extension Module RDIO-01 Digital I/O Extension Module RDIO-01 User s Manual 3AFE 64485733 REV B EN EFFECTIVE: 10.2.2003 2003 ABB Oy. All Rights Reserved. Safety Instructions

More information

Before using the product, thank you for purchasing SV-iS7 DeviceNet option board. SAFETY PRECAUTIONS

Before using the product, thank you for purchasing SV-iS7 DeviceNet option board. SAFETY PRECAUTIONS Before using the product, thank you for purchasing SV-iS7 DeviceNet option board. SV - is7 DeviceNet Manual SAFETY PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards

More information

Before using the product, thank you for purchasing MDLV-HP DeviceNet option board. SAFETY PRECAUTIONS

Before using the product, thank you for purchasing MDLV-HP DeviceNet option board. SAFETY PRECAUTIONS Before using the product, thank you for purchasing MDLV-HP DeviceNet option board. SAFETY PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety

More information

DeviceNet Communication Manual

DeviceNet Communication Manual DeviceNet Communication Manual Frequency Inverter Series: CFW-11 Language: English Document: 10000104642 / 00 04/2008 Summary ABOUT THIS MANUAL... 5 ABBREVIATIONS AND DEFINITIONS... 5 NUMERICAL REPRESENTATION...

More information

Options for ABB drives. User s manual FPTC-01 thermistor protection module (option +L536) for ACS880 drives

Options for ABB drives. User s manual FPTC-01 thermistor protection module (option +L536) for ACS880 drives Options for ABB drives User s manual FPTC-01 thermistor protection module (option +L536) for ACS880 drives List of related manuals Drive hardware manuals Code (EN) ACS880-01 hardware manual 3AUA0000078093

More information

DeviceNet Drive Profile CFW-09

DeviceNet Drive Profile CFW-09 Motors Automation Energy Transmission & Distribution Coatings DeviceNet Drive Profile CFW09 Communication Manual DeviceNet Drive Profile Communication Manual Serie: CFW09 Language: English Software Version:

More information

L5351 DeviceNet Communications Interface

L5351 DeviceNet Communications Interface L5351 DeviceNet Communications Interface Technical Manual HG353798 Issue 2 Copyright SSD Drives, Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or

More information

Technical Manual Type SI-N3

Technical Manual Type SI-N3 YASKAWA AC Drive-Option Card DeviceNet Technical Manual Type SI-N3 To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user

More information

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1

Preface Digital Electronics Corporation. All rights reserved. Digital Electronics Corporation December LT Type-D User Manual Supplement 1 Preface Thank you for purchasing the Pro-face LogiTouch Type-D DeviceNet master unit. The LogiTouch Type-D (also referred to as the LT Type-D ) allows connection to the DeviceNet Fieldbus to access many

More information

DN-01 Instruction Manual

DN-01 Instruction Manual DN-01 Instruction Manual DeviceNet communication expansion board V 1.00 This instruction manual is only for the Shihlin communication expansion board DN-01. Please refer to ODVA DeviceNet specification

More information

CANopen CFW100. User s Manual. Phone: Fax: Web: -

CANopen CFW100. User s Manual. Phone: Fax: Web:  - CANopen CFW100 User s Manual CANopen User s Manual Series: CFW100 Language: English Document Number: 10002835377 / 00 Publication Date: 06/2014 CONTENTS CONTENTS... 3 ABOUT THE MANUAL... 5 ABBREVIATIONS

More information

DNP31.0 DeviceNet Interface

DNP31.0 DeviceNet Interface Technical description DNP31.0 DeviceNet Interface Data sheet Description The DNP31 devcie allows the connection of the Universal Motor Controller UMC100.3 to a DeviceNet network. Please note the following

More information

Thank you for purchasing ig5a Series DeviceNet Communication Module SAFETY PRECAUTIONS

Thank you for purchasing ig5a Series DeviceNet Communication Module SAFETY PRECAUTIONS Safety Precautions Thank you for purchasing ig5a Series DeviceNet Communication Module SAFETY PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety

More information

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation

DeviceNet Module. User Manual. 1 Important User Information. 2 Installation User Manual 1 Important User Information Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning. It is the installer's

More information

G3 Series DeviceNet TM Technical Manual

G3 Series DeviceNet TM Technical Manual G3 Series DeviceNet TM Technical Manual Table of Contents G3 Series DeviceNet Technical Manual PAGE About DeviceNet... 3 Overview... 3 G3 DeviceNet Features... 3 Cabling and Drop Line Lengths (as defined

More information

Installation Guide VLT DeviceNet MCA 104

Installation Guide VLT DeviceNet MCA 104 MAKING MODERN LIVING POSSIBLE Installation Guide VLT DeviceNet MCA 104 VLT Frequency Converter Series FC 102 FC 202 FC 301 FC 302 vlt-drives.danfoss.com Contents Installation Guide Contents 1 Introduction

More information

ABB wind turbine converters. Supplement ACS slide-out frame (+P919)

ABB wind turbine converters. Supplement ACS slide-out frame (+P919) ABB wind turbine converters Supplement ACS800-67 slide-out frame (+P919) List of related manuals ACS800-67 manuals ACS800-67 wind turbine converters for asynchronous slip ring generators hardware manual

More information

SMV DeviceNet TM Communications Module Communications Interface Reference Guide

SMV DeviceNet TM Communications Module Communications Interface Reference Guide SMV DeviceNet TM Communications Module Communications Interface Reference Guide About These Instructions This documentation applies to the optional DeviceNet communications module for the SMVector inverter

More information

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules)

Checking the compatibility with IT (ungrounded) and corner-grounded delta systems. EMC filter +E200 (690 V drives and drive modules) Update notice Update notice 1 The notice concerns the ACS880-04XT hardware manuals listed below. Contents of the notice: Checking the compatibility of the drive with IT (ungrounded) and cornergrounded

More information

DeviceNet Interface Option "OPC-E1-DEV"

DeviceNet Interface Option OPC-E1-DEV Instruction Manual DeviceNet Interface Option "OPC-E1-DEV" Thank you for purchasing our DeviceNet Interface Option OPC-E1-DEV. This product is designed to connect the FRENIC-Multi series of inverters to

More information

ABB industrial drives. Safety instructions ACS880 multidrive cabinets and modules

ABB industrial drives. Safety instructions ACS880 multidrive cabinets and modules ABB industrial drives Safety instructions ACS880 multidrive cabinets and modules Safety instructions ACS880 multidrive cabinets and modules Table of contents 2. Safety instructions 2017 ABB Oy. All Rights

More information

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide

BNI DNT Z004 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005 BNI DNT Z005. User s Guide BNI DNT-104-000-Z004 BNI DNT-202-000-Z005 BNI DNT-302-000-Z005 BNI DNT-305-000-Z005 BNI DNT-305-007-Z005 User s Guide Contents 1 User instructions 3 1.1. Structure of the guide 3 1.2. Typographical conventions

More information

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison

DNETEXT-C CAN Bus Extender, Version 3 User s Manual. Brad Harrison DNETEXT-C CAN Bus Extender, Version 3 User s Manual Brad Harrison Although every effort has been made to insure the accuracy of this document, all information is subject to change without notice. Woodhead

More information

VLT 5000 DeviceNet and Allen Bradley Control logix 5550

VLT 5000 DeviceNet and Allen Bradley Control logix 5550 Foreword... 2 VLT 5000 DeviceNet card... 2 Configuring the VLT 5000 with RS Networx... 4 I/O communication with RS Logix 5000... 6 Explicit messages with RS Logix 5000... 8 1 Foreword This application

More information

Options for ABB drives. User s manual FPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (option +L537+Q971) for ACS880 drives

Options for ABB drives. User s manual FPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (option +L537+Q971) for ACS880 drives Options for ABB drives User s manual FPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (option +L537+Q971) for ACS880 drives List of related manuals Drive hardware manuals Code (EN) ACS880-01

More information

Options for ABB drives. User s manual FPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (option +L537+Q971) for ACS880 drives

Options for ABB drives. User s manual FPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (option +L537+Q971) for ACS880 drives Options for ABB drives User s manual FPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (option +L537+Q971) for ACS880 drives List of related manuals Drive hardware manuals Code (EN) ACS880-01

More information

Install the DeviceNet Module using the following procedure:

Install the DeviceNet Module using the following procedure: Installation INSTALLATION INSTRUCTIONS: MCD DEVICENET MODULE Order Code: 175G9002 1. Installation Install the DeviceNet Module using the following procedure: 1. Remove control power and mains supply from

More information

DeviceNet. Technical Manual. Inverter HF-520 Option

DeviceNet. Technical Manual. Inverter HF-520 Option Inverter HF-520 Option DeviceNet Technical Manual Type: SI-N3/V-H NOTICE 1. Make sure that this technical manual is dellvered to the end user of inverter unit. 2. Read this manual before installing or

More information

PROFIBUS for motor controller CMMS/CMMD

PROFIBUS for motor controller CMMS/CMMD Trimming: On top: 61.5 mm Underneath: 61.5 mm Left: 43.5 mm Right: 43.5 mm PROFIBUS for motor controller CMMS/CMMD Description DeviceNet CMMS-ST CMMS-AS CMMD-AS Description 554 358 en 1103a [757 722] Edition

More information

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE

MODBUS RTU MODULE INSTRUCTIONS. for use with WSIQ2/WSE INSTRUCTIONS MODBUS RTU MODULE for use with WSIQ2/WSE WorldWide Electric Corporation Phone: 1-8-88-2131 Fax: 1-8-711-1616 www.worldwideelectric.net Product Compatibility This communications module is suitable

More information

DeviceNet PCI Card Instructions Manual

DeviceNet PCI Card Instructions Manual Motoman NX100 Controller DeviceNet PCI Card Instructions Manual Part Number: 151799-1CD Revision: 0 Motoman, Incorporated 805 Liberty Lane West Carrollton, OH 45449 TEL: (937) 847-6200 FAX: (937) 847-6277

More information

Communication Network. DeviceNet Communication

Communication Network. DeviceNet Communication Communication Network DeviceNet Communication Communication Network DeviceNet Communication Edition: April 2015 SD70BC04DI Rev. D 2 SAFETY SYMBOLS Always follow safety instructions to prevent accidents

More information

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents

Section 1.0 Description Section 2.0. Section 3.0. Section 4.0. MCD3000 DeviceNet Gateway. Contents Section 1.0 Description... 2 Section 2.0 Installation 2.1 Soft starter to gateway connection... 3 2.2 Soft starter configuration... 3 2.3 Gateway to DeviceNet connection... 3 2.4 Gateway configuration...

More information

Before using the product, thank you for using our Ethernet module board. Safety Instruction

Before using the product, thank you for using our Ethernet module board. Safety Instruction ig5a Ethernet Option Manual Before using the product, thank you for using our Ethernet module board. Safety Instruction To prevent injury and danger in advance for safe and correct use of the product,

More information

Start-up Guide. AF 100 Adapter Kit NAFA-01

Start-up Guide. AF 100 Adapter Kit NAFA-01 ABB Drives Installation and Start-up Guide AF 100 Adapter Kit NAFA-01 AF 100 Adapter Kit NAFA-01 Installation and Start-up Guide 3BFE 58919837 R0125 EFFECTIVE: 17.07.2000 SUPERSEDES: None Safety Instructions

More information

ABB industrial drives. Supplement ACS880 override control program (option +N5450)

ABB industrial drives. Supplement ACS880 override control program (option +N5450) ABB industrial drives Supplement ACS880 override control program (option +N5450) List of related manuals Drive firmware manuals ACS880 primary control program firmware manual ACS880 drives with primary

More information

ACS850 User s Guide ACS850 Control Panel

ACS850 User s Guide ACS850 Control Panel ACS850 User s Guide ACS850 Control Panel ACS850 Control Panel User s Guide 3AUA0000050277 Rev A EN EFFECTIVE: 02.01.2009 2009 ABB Oy. All Rights Reserved. 5 Table of contents Table of contents About the

More information

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module

SAFETY PRECAUTIONS CAUTION WARNING CAUTION. Thank you for purchasing ig5a Series Profibus Communication Module SAFETY PRECAUTIONS Thank you for purchasing ig5a Series Profibus Communication Module SAFETY PRECAUTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring. Safety

More information

X-gateway Interface Addendum DeviceNet Scanner Interface

X-gateway Interface Addendum DeviceNet Scanner Interface X-gateway Interface Addendum DeviceNet Scanner Interface Rev. 1.10 HMS Industrial Networks AB Germany Japan Sweden U.S.A + 49-721 - 96472-0 + 81-45 - 478-5340 + 46-35 - 17 29 20 + 1-773 - 404-3486 ge-sales@hms-networks.com

More information

115/230 VAC Digital Input Module OHDI-01

115/230 VAC Digital Input Module OHDI-01 Drive IT Low Voltage AC Drives User s Manual 115/230 VAC Digital Input Module OHDI-01 OHD4 2 115/230 VAC Digital Input Module OHDI-01 Safety WARNING! All electrical installation and maintenance work on

More information

ABB industrial drives. Supplement ACS880 Centrifuge Decanter control program (+N5150)

ABB industrial drives. Supplement ACS880 Centrifuge Decanter control program (+N5150) ABB industrial drives Supplement ACS880 Centrifuge Decanter control program (+N5150) List of related manuals Drive hardware manuals ACS880-01 drives hardware manual Code (English) 3AUA0000078093 Drive

More information

Motors I Automation I Energy I Transmission & Distribution I Coatings. CANopen CFW500. User s Manual

Motors I Automation I Energy I Transmission & Distribution I Coatings. CANopen CFW500. User s Manual Motors I Automation I Energy I Transmission & Distribution I Coatings CANopen CFW500 User s Manual CANopen User s Manual Series: CFW500 Language: English Document Number: 10002253105 / 00 Publication Date:

More information

YASKAWA AC Drive Option DeviceNet. Technical Manual

YASKAWA AC Drive Option DeviceNet. Technical Manual YASKAWA Option DeviceNet Technical Manual Type SI-N3 To properly use the product, read this manual thoroughly and retain for easy reference, inspection, and maintenance. Ensure the end user receives this

More information

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB BridgeWay PROFIBUS to DeviceNet Gateway User Manual Part No. AB7605 Pyramid Solutions 1850 Research Drive, Suite 300 Troy, Michigan 48083 Phone 248-524-3890 Web www.pyramid-solutions.com Publication PUB-AB7605-005

More information

Safety Instruction. This symbol indicates the possibility of injury or damage to property.

Safety Instruction. This symbol indicates the possibility of injury or damage to property. ig5a Ethernet Option Manual Safety Instruction To prevent injury and danger in advance for safe and correct use of the product, be sure to follow the Safety Instructions. The instructions are divided as

More information

UNITRONICS ETHERNET/IP COMMS WITH A FENA-01/11/21 ADAPTER MODULE

UNITRONICS ETHERNET/IP COMMS WITH A FENA-01/11/21 ADAPTER MODULE UNITRONICS ETHERNET/IP COMMS WITH A FENA-01/11/21 ADAPTER MODULE Description: This document describes demonstration programs that implement different types of Ethernet/IP communications links between a

More information

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05

Sigma DeviceNet Tool Change Systems USER S GUIDE Rev 05 Sigma DeviceNet Tool Change Systems USER S GUIDE 94018 Rev 05 648 Saratoga Road Glenville, NY 12302 USA Phone: 518 384 1000 Fax 518 384 1200 www.arobotics.com 1. PRECAUTIONS 1 Sigma DNET Module 1 2.0 DNET

More information

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module Installation and Setup 1 2 In This Chapter.... Installing the H0 PSCM The Profibus Network Configuring the Module 2 2 Installing the H0 PSCM Remove the Slot Cover The first step in installing the option

More information

DeviceNet Interface Card "OPC-F1-DEV"

DeviceNet Interface Card OPC-F1-DEV Instruction Manual DeviceNet Interface Card "OPC-F1-DEV" Thank you for purchasing our DeviceNet Interface Card OPC-F1-DEV. This product is designed to connect the FRENIC-Eco series of inverters to DeviceNet.

More information

CANopen CFW-11. Communication Manual. Phone: Fax: Web:

CANopen CFW-11. Communication Manual. Phone: Fax: Web: Motors Automation Energy Transmission & Distribution Coatings CApen CFW-11 Communication Manual Language: English CApen Communication Manual Series: CFW-11 Language: English Document Number: 0899.5747

More information

Installation and maintenance instructions

Installation and maintenance instructions Before installation these instructions must be fully read and understood Table of contents 1. Introduction... 1 2. Operation and storage... 1 3. Distinguish OLD/NEW models... 1 4. Installation... 3 4.1

More information

OPTIONS FOR ABB DRIVES CPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (+L537+Q971) User s manual

OPTIONS FOR ABB DRIVES CPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (+L537+Q971) User s manual OPTIONS FOR ABB DRIVES CPTC-02 ATEX-certified thermistor protection module, Ex II (2) GD (+L537+Q971) User s manual List of related manuals Drive hardware manuals and guides Code (English) Drive/converter/inverter

More information

SMARTLINX INTERFACE MODULE

SMARTLINX INTERFACE MODULE SMARTLINX INTERFACE MODULE FOR DEVICE NET Instruction Manual PL-583 April 2001 R 33455830 Rev. 1.1 Safety Guidelines Warning notices must be observed to ensure personal safety as well as that of others,

More information

SMVector Additional I/O Module Installation and Operation Manual

SMVector Additional I/O Module Installation and Operation Manual SMVector Additional I/O Module Installation and Operation Manual About These Instructions This documentation applies to the optional Additional I/O module for the SMVector inverter and should be used in

More information

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web:  - Anybus-CC CFW-11 User s Manual Anybus-CC User s Manual Series: CFW-11 Language: English Document Number: 0899.5750 / 06 Publication Date: 09/2013 CONTENTS CONTENTS... 3 ABOUT THE MANUAL... 6 ABBREVIATIONS

More information

GPD 515/G5 DeviceNet Technical Manual

GPD 515/G5 DeviceNet Technical Manual GPD 515/G5 DeviceNet Technical Manual Technical References Refer to the following publications for further information about the GPD 515/G5 and DeviceNet. GPD 515/G5 Technical Manual Publication TM 4515

More information

MITSUBISHI TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- Option. DeviceNet TM FR-E5ND MITSUBISHI ELECTRIC

MITSUBISHI TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- Option. DeviceNet TM FR-E5ND MITSUBISHI ELECTRIC MITSUBISHI TRANSISTORIZED INVERTER -INSTRUCTION MANUAL- DeviceNet TM Option FR-E5ND MITSUBISHI ELECTRIC Thank you for choosing the Mitsubishi transistorized inverter option unit. This instruction manual

More information

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check

GE FANUC Parts 1. DeviceNet Network Master/Slave August 2002 GFK-1539A. Quick Start Guide. Product Description. Specifications. Preinstallation Check Product Description Revision Letter: BA Firmware version: 1.10 Firmware upgrades: DeviceNet Certification: Product Name: None Certificate available upon request. DeviceNet Network Control Module (NCM)

More information

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment.

MCD 200 Series. MCD 200 DEVICENET Module OPERATING INSTRUCTIONS. MCD 200 DEVICENET Module. Order Code: 175G9002. Adjustment. Installation OPERATING INSTRUCTIONS Order Code: 175G9002 Adjustment 35 mm (1.38 inches) Control power and mains supply must be removed from the MCD 200 before attachment or removal of an accessory module.

More information

Profinet Module. User Manual. Contents

Profinet Module. User Manual. Contents User Manual Contents 1 Important User Information... 2 2 Installation... 3 3 Connection... 4 4 Device Configuration... 5 5 Operation... 7 6 Packet Structures... 8 7 Network Design... 16 8 Specifications...

More information

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB

- 15G0078B120 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-1/ASAB - 5G0078B0 - DEVICENET MODULE INSTRUCTIONS FOR ASAC-0/ASAC-/ASAB Issued on 5/06/ R. 0 This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide

More information

DeviceNet Interface Option "OPC-E1-DEV"

DeviceNet Interface Option OPC-E1-DEV Instruction Manual DeviceNet Interface Option "OPC-E1-DEV" Thank you for purchasing our DeviceNet Interface Option OPC-E1-DEV. This product is designed to connect the FRENIC-Multi series of inverters to

More information

Application guide ACS355 and AC500-eCo.

Application guide ACS355 and AC500-eCo. Application guide ACS355 and AC500-eCo www.infoplc.net List of related manuals Drive and PLC hardware manuals and guides Code (English) ACS355 user s manual 3AUA0000066143 2) AC500-eCo and ACS355 quick

More information

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board

PowerFlex DC Drive Frame B Pulse Transformer Circuit Board Installation Instructions PowerFlex DC Drive Frame B Pulse Transformer Circuit Board ATTENTION: Only qualified personnel familiar with DC drives and associated machinery should plan or implement the installation,

More information

PROFIBUS Adapter. 20-COMM-P FRN 1.xxx. User Manual

PROFIBUS Adapter. 20-COMM-P FRN 1.xxx. User Manual PROFIBUS Adapter 20-COMM-P FRN 1.xxx User Manual Important User Information Solid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines

More information

Softstarters. Type PSE Fieldbus Communication Fieldbus Plug DeviceNet. 1SFC132066M0201 January SFC132066M0201 1

Softstarters. Type PSE Fieldbus Communication Fieldbus Plug DeviceNet. 1SFC132066M0201 January SFC132066M0201 1 Softstarters Type PSE Fieldbus Communication Fieldbus Plug DeviceNet 1SFC132066M0201 January 2019 1SFC132066M0201 1 1 DeviceNet DeviceNet is a digital, multi-drop network that connects and serves as a

More information

Resolver to Digital Expansion Board

Resolver to Digital Expansion Board Resolver to Digital Expansion Board Catalog No. EXB009A01 Installation and Operating Manual 6/98 MN1313 Table of Contents Section 1 General Information............................. 1-1 Introduction....................................

More information

DeviceNet CM059 (SI-N1) Option Technical Manual

DeviceNet CM059 (SI-N1) Option Technical Manual DeviceNet CM059 (SI-N1) Option Technical Manual For Option: CM059 (SI-N1) Models: CIMR-G5*, CIMR-F7*, CIMR-G7*, CIMR-ACA* Document Number TM.AFD.13 This page intentionally blank. 2 Warnings and Cautions

More information