Conettix Plug-in Communicator Interface

Size: px
Start display at page:

Download "Conettix Plug-in Communicator Interface"

Transcription

1 Conettix Plug-in Communicator B450 en Installation and Operation Guide

2

3 Conettix Plug-in Communicator Table of Contents en 3 Table of contents 1 Safety 4 2 Introduction About documentation Bosch Security Systems, Inc. product manufacturing dates Installation workflow 6 3 System overview Module overview B450 cellular interface compatibility Bus address settings overview 9 4 Installation Setting the bus address Insert the communication module Insert the B44x communication module (required and available separately) Insert the B44x communication module with SIM card (required and available 13 separately) 4.3 Mount the module in the enclosure Mount and wire the tamper switch (option for SDI2 bus only) Install and mount the plug-in communicator antenna Wire to the control panel Wire to an SDI2 control panel Wire to an SDI control panel Wire to an option bus control panel 19 5 Configuration Configuration for SDI2 control panels Configuring and viewing status from RPS Use USB to configure the B Install a communication program Log into the USB interface USB Main menu USB menu structure USB menu Short Message Service (SMS) configuration Use SMS to configure the B Firmware Update page 52 6 Maintenance and troubleshooting USB menu access disabled LED status indicators Show the firmware version SIM card Diagnostic log Understanding network polling Control panel programming using cellular 61 7 Specifictions and certifications Technical specification Certifications 64 Bosch Security Systems, Inc. Installation and Operation Guide F.01U

4 4 en Safety Conettix Plug-in Communicator 1 Safety ESD Precaution Please note that while the B450 comes in a plastic case, and is protected from ESD, the plugin cellular communicator (B44x) does not. All plug-in cellular communicator components may potentially be exposed to finger touches - therefore extra attention must be paid to ESD (electrostatic discharge) precaution. Make sure there is no static interference when using the board. Appropriate ESD protections must be taken and wearing electrostatic equipment is recommended, such as anti-static wrist strap. ESD damage can range from subtle performance degradation to complete device failure. Precision integrated circuits may be more susceptible to damage because very small parametric changes could cause the device not to meet its published specifications.! Warning! Failure to follow these instructions can result in a failure to initiate alarm conditions. Bosch Security Systems, Inc. is not responsible for improperly installed, tested, or maintained devices. Follow these instructions to avoid personal injury and damage to the equipment. Inform the operator and the local authority having jurisdiction (AHJ) before installing the module in an existing system. Disconnect all power to the control panel before installing the module F.01U Installation and Operation Guide Bosch Security Systems, Inc.

5 Conettix Plug-in Communicator Introduction en 5 2 Introduction This document supports the B450 with firmware version v About documentation Copyright This document is the intellectual property of Bosch Security Systems, Inc. and is protected by copyright. All rights reserved. Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly. 2.2 Bosch Security Systems, Inc. product manufacturing dates Use the serial number located on the product label and refer to the Bosch Security Systems, Inc. website at Bosch Security Systems, Inc. Installation and Operation Guide F.01U

6 6 en Introduction Conettix Plug-in Communicator 2.3 Installation workflow To install and configure the module, use the workflow below and follow in sequential order from top to bottom, checking off each box as you complete a step.! Caution! Always power down the control panel when connecting a module. To power down the control panel, unplug the transformer and disconnect the battery. Plan the installation of the B450 Conettix Plug-in Communicator Unpack the device contents Power down the system Select the bus address value for the compatible control panel (This will automatically configure the module to work with a compatible control panel. Refer to Setting the bus address, page 11) Insert the desired plug-in communicator into the B450 (Refer to Insert the communication module, page 12) Mount the B450 into the enclosure (Refer to Mount the module in the enclosure, page 14) Wire the B450 to a compatible control panel (Refer to Wire to the control panel, page 16) Power up the system Install a communication program (if required) (Refer to Install a communication program, page 28) Configure the communication module (non SDI2 control panels) Verify LED activity Review signal strength on the cellular communicator. Refer to your cellular communicator Installation Guide for more information on signal strength. Installation is complete F.01U Installation and Operation Guide Bosch Security Systems, Inc.

7 Conettix Plug-in Communicator System overview en 7 3 System overview Refer to the graphic below for the complete B450 system configuration B450 system connections overview Callout ᅳ Description Callout ᅳ Description 1 ᅳ Compatible Bosch control panel 8 ᅳ Ethernet network connection between the host computer Ethernet network interface card (NIC) and the Ethernet network 2 ᅳ Data bus connection between the control panel and the B450 module 9 ᅳ Host PC running Remote Programming Software, Automation, or Conettix D6200 Programming/ Administration Software 3 ᅳ B ᅳ Conettix D6100i Communications Receiver/Gateway and/or Conettix D6600 Communications Receiver/ Gateway (Conettix D6600 Communications Receiver/Gateway requires 11, 12, and 13) 4 ᅳ USB direct connection for B450 configuration (if required) 5 ᅳ B44x Plug-in Cellular Communicator (required and available separately) 11 ᅳ Ethernet network connection to the Ethernet adapter (D6680/ITS- D6682/ITS-D6686) (ITS-D6682 shown) Ethernet Network Adapter 12 ᅳ Conettix Ethernet Network Adapter (ITS-D6682 shown) Bosch Security Systems, Inc. Installation and Operation Guide F.01U

8 8 en System overview Conettix Plug-in Communicator 6 ᅳ Cellular carrier network 13 ᅳ Connection from ITS-D6682 to the COM4 Port on the Conettix D6600 Communications Receiver/Gateway 7 ᅳ Internet 14 ᅳ Ethernet network connection to the D6100i Communications Receiver (D6100i/D6100IPv6) 3.1 Module overview The B450 Conettix Plug-in Communicator (wired to a compatible control panel) is a four-wire powered SDI2, or SDI device that provides two-way communication over commercial cellular networks using a plug-in communicator. The B450 Conettix Plug-in Communicator bus address switch determines the bus address of the device. When required, configuration of the module is managed through the control panel, a local USB connection, or using SMS. B450 module overview TX RX Figure 3.1: B450 Plug-in Communicator Callout ᅳ Description 1 ᅳ Tamper switch connector 2 ᅳ Bus address switch 3 ᅳ MODE 2-pin jumper connector (for future use) 4 ᅳ Bus address label 5 ᅳ USB connector (Type A) 6 ᅳ Heartbeat LED 7 ᅳ RX LED (indicates packets received from the wireless network) F.01U Installation and Operation Guide Bosch Security Systems, Inc.

9 Conettix Plug-in Communicator System overview en 9 8 ᅳ TX LED (indicates packets transmitted over the wireless network) 9 ᅳ Terminal strip (to control panel) 10 ᅳ Interconnect wiring connectors (to control panel or other compatible modules) 3.2 B450 cellular interface compatibility The B450 supports multiple bus types. Use the following table to determine the supported applications and features by bus type. the following table for supporting compatibility applications. Installed Bus Function Option/SDI SDI2 Details IP Event Reporting Y Y TCP communication is only supported on SDI2 Remote Program (RPS or A-link) Configure B450 from control panel Personal Notification via SMS or Remote Security Control App Y Y Requires Bosch Cellular service or other cellular network access N Y GV4/B Series require v2.03+ N Y Requires compatible control panel and cellular plan N Y Requires Bosch Cellular service or other cellular network access Table 3.1: B450 cellular interface compatibility 3.3 Bus address settings overview The address switch determines the bus address for the B450 Conettix Plug-in Communicator. The control panel uses the address for communications. Use a slotted screwdriver to set the address switch. The B450 reads the bus address switch setting only during power up. If you change the switch after you apply power to the module, you must cycle the power to the module in order for the new bus address setting to be used for bus communication. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

10 10 en System overview Conettix Plug-in Communicator Bus address label Use the bus address label to select the desired setting on the bus address switch, depending on your control panel. PANEL ADDRESSES Bus cfg Addr SDI2 SDI Option TX RX Figure 3.2: Bus address label F.01U Installation and Operation Guide Bosch Security Systems, Inc.

11 Conettix Plug-in Communicator Installation en 11 4 Installation Perform the following steps to install the B450.! Caution! Remove all power (AC and battery) before making any connections. Failure to do so might result in personal injury and/or equipment damage. 4.1 Setting the bus address The B450 Conettix Plug-in Communicator address switch provides the value for the module's address. The figure below shows the address switch setting for address 1. Refer to the table below for panel-specific settings. Figure 4.1: Address switch set to address 1 Control panels Switch position Control panel bus address Bus type Function USB or SMS configuration setting B5512/B4512/ B3512,D9412GV4/ D7412GV4/D7212GV4 Solution 2000/3000 D9412GV4/D7412GV4/ D7212GV4 Solution 2000/3000 D9412GV4/D7412GV4/ D7212GV4, D9412GV3/ D7412GV3/D7212GV3, D9412GV2/ D7412GV2/7212GV2 v7.06+ D9412GV4/D7412GV4/ D7212GV4, D9412GV3/ D7412GV3/D7212GV3 0 N/A Any Change configuration 1 1 SDI2 Automation, Remote Programming, or Reporting 2 2 SDI2 Automation, Remote Programming, or Reporting 4 88 SDI 1 Remote Programming or Reporting 5 92 SDI 1 Remote Programming or Reporting AMAX 2000/2100/3000/ Option Remote Programming or Reporting CMS 6/8, CMS Option Remote Programming or Reporting Easy Series v Option Remote Programming or Reporting Bosch Security Systems, Inc. Installation and Operation Guide F.01U

12 12 en Installation Conettix Plug-in Communicator Control panels Switch position Control panel bus address Bus type Function FPD Option Remote Programming or Reporting 1 For D9412GV4/D7412GV4/D7212GV4 configurations, SDI2 bus connection is the recommended configuration option, but SDI bus configuration is also supported. Table 4.1: B450 address switch settings Address switches 3, 7, and 8 are not supported on the B Insert the communication module Insert the desired B44x communication module into the slot of the B450 until you feel the module click into place. Review your communication module prior to insertion into the B450. Depending on the physical attributes of your communication module, insert your module accordingly using the supported installation process (Section without a SIM card, or Section with a SIM card) F.01U Installation and Operation Guide Bosch Security Systems, Inc.

13 Conettix Plug-in Communicator Installation en Insert the B44x communication module (required and available separately) Figure 4.2: Inserting the communication module into the B450 Callout ᅳ Description 1 ᅳ B44x Plug-in Communicator module (available separately) 2 ᅳ B450 Conettix Plug-in Communicator Insert the B44x communication module with SIM card (required and available separately) Insert the desired B44x communication module with supporting SIM card into the slot of the B450 until you feel the module click into place. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

14 14 en Installation Conettix Plug-in Communicator Figure 4.3: Inserting the communication module with supporting SIM card into the B450 Callout ᅳ Description 1 ᅳ B44x Plug-in Communicator SIM card insertion (required and, available separately) 2 ᅳ B44x Plug-in Communicator module (available separately) 3 ᅳ B450 Conettix Plug-in Communicator 4.3 Mount the module in the enclosure If you are not using the interconnect cable, it is recommended to wire the B450 module to the compatible control panel via the terminal strip prior to mounting the B450 into the enclosure. Failure to do so will complicate the mounting procedure. Mount the B450 Conettix Plug-in Communicator using the interior wall of the enclosure s 3-hole mounting pattern and the supplied mounting screws. UL requirement Mount the module in the control panel enclosure, or in a UL listed enclosure. For Commercial Burglary applications, house all communicators in tampered enclosures. All communicators shall be housed in tampered enclosures. If the unit is used in a commercial burglar environment, and is enclosed in a commercial enclosure, that enclosure must be tampered. If the installation is a local or police station connection, then the B450 must be mounted inside an attack resistant enclosure F.01U Installation and Operation Guide Bosch Security Systems, Inc.

15 Conettix Plug-in Communicator Installation en 15 Figure 4.4: Mounting the module to the exterior wall of the enclosure Callout ᅳ Description 1 ᅳ B450 2 ᅳ Enclosure (outside wall shown) 3 ᅳ Mounting screws (3 screws included) Installing in a control panel enclosure Install the B450 on the inside enclosure wall that also contains the supported control panel. The control panel powers the B450 via the terminal block or bus connection. Installing in a separate enclosure Install the B450 on the inside wall of a separate enclosure. The control panel in a nearby, separate enclosure powers the B450 via the terminal block or bus connection. Installing in a separate enclosure with separate power supply Install the B450 on the inside wall of a separate enclosure that also has a separate external power supply such as the B520 Auxiliary Power Supply Module Mount and wire the tamper switch (option for SDI2 bus only) When the tamper input is shorted, the firmware version flashes, then the B450 LEDs are disabled to conserve power. To see the troubleshooting LEDs, open the tamper circuit or jumper. You can connect an enclosure door tamper switch for one module in an enclosure. Installing the optional tamper switch for use with a B450: 1. Mount the tamper switch into the enclosure s tamper switch mounting location. 2. Plug the tamper switch wire onto the module s tamper switch connector. For the tamper switch connector location, refer to Module overview, page Verify the B450 module is configured with tamper enabled ON within the SDI2 supported control panel. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

16 16 en Installation Conettix Plug-in Communicator 4.4 Install and mount the plug-in communicator antenna Installing and mounting the magnetic antenna: 1. Place the magnetic antenna on top of the enclosure, or vertically on another metal surface. If you are experiencing a weak signal, place the antenna on top of a metal surface that has a radius of cm (4 in) for optimal performance. 2. Route the antenna cable through a knock-out in the enclosure wall. 3. Connect the antenna cable to the module. 4. Secure the antenna cable to the inside of the enclosure. 5. Secure the extra antenna cable length inside the enclosure. 1 2 Figure 4.5: Antenna installation Callout ᅳ Description 1 ᅳ B44x plug-in cellular communicator antenna (routed through any knock-out) 2 ᅳB44x plug-in cellular communicator antenna cable (connected to the module) 4.5 Wire to the control panel When you wire a module to an SDI, or SDI2 control panel, you can use either the module's terminal strip labeled R, Y, G, B (PWR, A, B, COM) or the module's interconnect wiring connectors (wire included). The figure below indicates the location of both the terminal strip and the interconnect wiring connectors on the module F.01U Installation and Operation Guide Bosch Security Systems, Inc.

17 TMPR TMPR B C OUTPUT B C OUTPUT RESET RESET Conettix Plug-in Communicator Installation en 17 Use either the terminal strip wiring or interconnect cable to wire to the control panel. Do not use both. When connecting multiple modules, you can combine terminal strip and interconnect wiring connectors to daisy-chain the modules in series Wire to an SDI2 control panel Run the wiring connections from the module to the data bus terminals on the compatible control panel. SDI2 ON-BOARD POINTS Voltage Ranges Device Bus 1 R Y G B 1 Open Normal Short VDC VDC VDC C OUTPUT B SDI2 Device Bus R Y G B ON-BOARD POINTS Voltage Ranges VDC VDC VDC 1 k End of Line Resistors 1 k End of Line Resistors AUX AUX - 12 V + 1 COM 2 3 COM 4 5 COM 6 7 COM 8-12 V + 1 COM 2 3 COM 4 5 COM 6 7 COM 8 Open Normal Short C OUTPUT B COM AUX R Y G B PWR A B COM 1 COM 2 3 COM 4 5 COM 6 7 COM 8 COM AUX R Y G B PWR A B COM 1 COM 2 3 COM 4 5 COM 6 7 COM R Y G B R Y G B R Y G B Figure 4.6: Using terminal strip or interconnect cable wiring on an SDI2 control panel (B Series control panel shown) Callout ᅳ Description 1 ᅳ Compatible SDI2 control panel (B Series control panel shown) 2 ᅳ B450 3 ᅳ Terminal strip wiring 4 ᅳ Interconnect cable Bosch Security Systems, Inc. Installation and Operation Guide F.01U

18 GREEN GREEN 18 en Installation Conettix Plug-in Communicator Wire to an SDI control panel electric shock, disconnect AC power and telephone lines D9412GV3 before servicing. Commercial Protected-Premises Control Panel SDI Connector Refer to the D9412GV3/D7412GV3 Approved Applications Compliance Guide (P/N: F01U143069) for System Wiring Diagram, Issue A and for compatible smoke detectors. 2-wire Compatible Identifier A. Minimum system requirements for Classification in accordance with ANSI/SIA CP : Reset Pin UL Listed and Classified control unit Model D9412GV3, D7412GV3, or D7212GV3; Disable all except Battery UL Listed and Classified keypad Model D1256, D1257, D1260, D1255, D1255R, or D1255RW; Charging and Programming UL Listed Local Bell POWER SUPPLY REQUIREMENTS The Power Supply provides a maximum of 1.4 Amps for the Control Panel and all Accessory Devices. For System Loading, refer to the D9412GV3/D7412GV3 Operation and Installation Guide (P/N: F01U143070). All external connections except Terminal 5 (battery positive) are inherently power limited. Requirements for battery standby time might reduce allowable output. (P/N: F01U143070) for Power Requirements relating to Terminals 6 and 7. Battery: Replace every 3 to 5 years with one or two Model D126 or D V Lead Acid Batteries. This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code). Not suitable for remote station protected premises services where separate transmission circuits are required for fire, supervisory (when applicable) and trouble signals when using D185. D9412GV3 Control Panel is UL Listed For Central Station, Remote Station, Local, Auxiliary, Proprietary, and Household Fire Alarm, and Central Station, Local, Proprietary, Police Station Connect, Household Burglar Alarm and Encrypted Line Security when communicating via a network. PERIPHERAL DEVICE CONNECTIONS NFPA Style 4.0 Signaling Line Circuits WARNING! To prevent risk of RED POWER + YELLOW GREEN BLACK DATA BUS A DATA BUS B COMMON ZONEX OUT 1 ZONEX IN 1 ZONEX OUT 2 26 ZONEX IN R Y G B R Y G B electric shock, disconnect AC power and telephone lines D9412GV3 before servicing. Commercial Protected-Premises Control Panel SDI Connector Refer to the D9412GV3/D7412GV3 Approved Applications Compliance Guide (P/N: F01U143069) for System Wiring Diagram, Issue A and for compatible smoke detectors. 2-wire Compatible Identifier A. Minimum system requirements for Classification in accordance with ANSI/SIA CP : Reset Pin UL Listed and Classified control unit Model D9412GV3, D7412GV3, or D7212GV3; Disable all except Battery UL Listed and Classified keypad Model D1256, D1257, D1260, D1255, D1255R, or D1255RW; Charging and Programming UL Listed Local Bell POWER SUPPLY REQUIREMENTS The Power Supply provides a maximum of 1.4 Amps for the Control Panel and all Accessory Devices. For System Loading, refer to the D9412GV3/D7412GV3 Operation and Installation Guide (P/N: F01U143070). All external connections except Terminal 5 (battery positive) are inherently power limited. Requirements for battery standby time might reduce allowable output. (P/N: F01U143070) for Power Requirements relating to Terminals 6 and 7. Battery: Replace every 3 to 5 years with one or two Model D126 or D V Lead Acid Batteries. This equipment should be installed in accordance with the NFPA 70 (National Electrical Code) and NFPA 72 (National Fire Alarm Code). Not suitable for remote station protected premises services where separate transmission circuits are required for fire, supervisory (when applicable) and trouble signals when using D185. D9412GV3 Control Panel is UL Listed For Central Station, Remote Station, Local, Auxiliary, Proprietary, and Household Fire Alarm, and Central Station, Local, Proprietary, Police Station Connect, Household Burglar Alarm and Encrypted Line Security when communicating via a network. PERIPHERAL DEVICE CONNECTIONS NFPA Style 4.0 Signaling Line Circuits WARNING! To prevent risk of RED POWER + YELLOW GREEN BLACK DATA BUS A DATA BUS B COMMON ZONEX OUT 1 ZONEX IN 1 ZONEX OUT 2 26 ZONEX IN R Y G B System is intended to be checked by a Qualified Technician at least every 3 years. The types of initiating circuits the control panel has been approved for are A, M, W, SS. The types of signaling the control panel has been approved for are DAC, OT, NC, RevPol. ZONEX POWER + 24 System is intended to be checked by a Qualified Technician at least every 3 years. The types of initiating circuits the control panel has been approved for are A, M, W, SS. The types of signaling the control panel has been approved for are DAC, OT, NC, RevPol. ZONEX POWER + 24 Point 1 Point 2 VOLTAGE RANGES Open VDC Short VDCZONEX COMMON 23 Normal VDC Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 Point 8, S3 Option Closed = 1 kω EOL Normal Operation Open =AB-12 UL Bell Box 220 kω Point 1 Point 2 VOLTAGE RANGES Open VDC Short VDCZONEX COMMON 23 Normal VDC Point 3 Point 4 Point 5 Point 6 Point 7 Point 8 Point 8, S3 Option Closed = 1 kω EOL Normal Operation Open =AB-12 UL Bell Box 220 kω Operation Monitor LED Pulses when Normal Flickers when Ringing Operation Monitor LED Pulses when Normal Flickers when Ringing Figure 4.7: Using terminal strip or interconnect cable wiring on an SDI control panel (GV3 Series control panel shown) Callout ᅳ Description 1 ᅳ Compatible SDI control panel (GV3 Series control panel shown) 2 ᅳ B450 3 ᅳTerminal strip wiring 4 ᅳ Interconnect cable F.01U Installation and Operation Guide Bosch Security Systems, Inc.

19 Conettix Plug-in Communicator Installation en Wire to an option bus control panel Run the wiring connections from the module to the data bus terminals on the compatible control panel. When wiring the connections between the option bus terminal strip and the B450, verify the terminal position of the colored wires as they may be in a different orientation (option bus = R, B, G, and Y) and (B450 = R, Y, G, and B). 1 2 R Y R Y R B G Y B G G B 3 Figure 4.8: Wiring to an option bus terminal strip ( Callout ᅳ Description 1 ᅳ Compatible control panel (FPD-7024 control panel shown) 2 ᅳ B450 3 ᅳ Terminal strip wiring For complete wiring instructions, refer to the control panel documentation. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

20 20 en Configuration Conettix Plug-in Communicator 5 Configuration Power up the system prior to the configuration workflows described in this chapter. You can configure the B450 using one of the methods described in this section for your control panel type. 5.1 Configuration for SDI2 control panels Perform the following to configure the B450 to supporting SDI2 control panels. By default, when connecting a field replacement B450 to an existing SDI2 control panel, the control panel overrides some of the module settings such as; TCP/UDP Port Number, AES Encryption, Tamper, Panel Programming, IPv4 DNS Server IP Address, Alternate IPv4 DNS Server IP Address, and TCP Keep Alive Time. To keep custom module settings when you connect a module to a configured control panel, you must disable Panel Programming prior to connecting to the SDI2 bus. This is accomplished by using either USB, or SMS configuration. If the SDI2 control panel is not defaulted, the control panel sends the network configuration parameters to the B450. Address-only configuration conditions An SDI2 control panel automatically configures a newly connected module. 1. If the control panel is not at factory default, it transfers the configuration settings in the control panel to the B Verify that the address switch is set to the correct address for the control panel (SDI2 control panels use address 1 or 2). If the switch is not set to the correct address, power down the system, set the correct address, and then power up the system. 3. Program the control panel communication settings using RPS or the keypad. The control panel stores the module settings and automatically programs a defaulted module when connected. If manual module programming is required, use USB or SMS configuration to set the Panel Programming parameter to Disabled before installing Configuring and viewing status from RPS Configuration For SDI2 control panels, the networking related parameters in the Networking parameters in RPS table can be configured through the panel or RPS. When cellular specific parameters need to be modified, refer to the USB or SMS configuration sections within this installation and operation guide for programming workflows and operation. The B450 parameters within RPS can be found under the SDI2 Modules section. Refer to the chart below for RPS selections: F.01U Installation and Operation Guide Bosch Security Systems, Inc.

21 Conettix Plug-in Communicator Configuration en 21 If your control panel configuration is a,. GV4 Series v1.00 Then use this menu within RPS, SDI2 Modules B420 Ethernet Communicator B Series/GV4 Series v2.00+ SDI2 Modules IP Communicator B B Series and GV4 Series control panels at firmware version with RPS version can use the B450 submenu to configure GSM cellular parameters specific to B442 and B443 Plug-in Cellular Communicators. Table 5.1: RPS settings based on control panel firmware versions Refer to the illustration below to locate the SDI2 Modules parameter within RPS. Figure 5.1: RPS SDI2 Modules location Common RPS configuration parameters Refer to the table below for parameters configured in RPS. The parameters listed in the following table support SDI2 control panel versions v2.00 and higher. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

22 22 en Configuration Conettix Plug-in Communicator Parameter Value Description Tamper (for GV4 ([v2.0x or higher] control panels) 0 = Disabled 1 = Enabled When enabled, allows tamper and tamper restore conditions to be reported to an SDI2 control panel. Only control panels with a SDI2 bus connection to the B450 can report a tamper condition. IPv4 DNS Server IP Address IPv4 address format ( ) The B450 uses the DNS server addresses supplied by the cellular network when the Primary DNS Server address option is configured as If the address is not configured as , the B450 installs the Primary DNS Server address. Web/USB access enabled Default: Yes Enabling Web/USB access on the B450 enables the USB menu, allowing for configuration programming. The B450 USB menu is enabled when the Web/USB Access Enabled parameter remains in the default selection of Yes. When disabled, the B450 shows a message stating: Menu access disabled. In the B Series and GV4 Series control panels, the default setting for Web/USB Access Enabled is set to No. USB menu access is NOT allowed unless the Web/USB Access Enabled parameter is changed to Yes in the control panel configuration. In non-sdi2 control panels, configuration via the control panel does not occur F.01U Installation and Operation Guide Bosch Security Systems, Inc.

23 Conettix Plug-in Communicator Configuration en 23 Parameter Value Description Web/USB access password Enter a 4 10 character password to access module programming Do not use the characters ; or! The web access password is used to allow access to module programming. For a B450 module, the password controls configuration from the USB menu and SMS text. TCP/UDP Port Number 1 to (7700) Sets the source port for the B450. Alternate IPv4 DNS Server IP Address IPv4 address format ( ) If the address is not configured at , the B450 installs the Alternate DNS Server address. TCP Keep Alive Time sec (45) This parameter determines how long to wait between transmissions to keep an idle TCP connection to a remote host from terminating due to inactivity. IPv4 Test Address IPv4 address format ( ) The IPv4 Test Address is used by the module to ping an internet address as part of the IP diagnostics. Table 5.2: B450 networking parameters configurable in RPS B450 IP Communicator settings The parameters listed below are configurable on control panels with firmware version Use the following settings to configure your cellular module parameters under the SDI2 IP Communicator B450 option (applicable for control panels with firmware version 2.03+). Bosch Security Systems, Inc. Installation and Operation Guide F.01U

24 24 en Configuration Conettix Plug-in Communicator Figure 5.2: B450 parameters Cellular configuration programming under the IP Communicator B450 section is not available in RPS with control panels using firmware version v v2.02. Cellular configuration for control panels with firmware version can only be done through the USB interface connected to the B450. Use RPS settings on Module 1 only. Module 2 must be configured through from the B450 through the USB menu. Diagnostics Information about the B450 such as it's Status, IP Address, Bus Voltage and the assigned phone number of the plug-in module can be found on the RPS Diagnostics screen. Depending on the firmware version of your control panel, you will see the following screens F.01U Installation and Operation Guide Bosch Security Systems, Inc.

25 Conettix Plug-in Communicator Configuration en 25 B450 status with version firmware Figure 5.3: B450 status shown in RPS Diagnostics with B Series/GV4 Series version B450 status with version B450 status as shown as Ethernet Communicator in RPS Diagnostics with GV4 version The following Diagnostic screen shown below is applicable to both B Series and GV4 Series control panels: Bosch Security Systems, Inc. Installation and Operation Guide F.01U

26 26 en Configuration Conettix Plug-in Communicator B450 status with version 1.00 B450 status as shown as Ethernet Communicator in RPS Diagnostics with GV4 v1.00. The plug-in communicator's phone number (if available) displays in the "Hostname" field. Refer to the illustration below. Figure 5.4: B450 status shown as Ethernet Communicator in RPS Diagnostics with GV4 version 1.00 RPS Diagnostics is not available when the module s connected to SDI or Option bus control panels. 5.2 Use USB to configure the B450 You can use a USB connection from a laptop PC to the B450 to configure the B450 on-site. The supported USB cable used to establish connection is a Male A to Male A cable. It is recommended to use a Bosch supported USB cable such as the B99 cable (F01U278853). Failure to do so may result in communication failures between the B450 and your computer. USB connection is for configuration or diagnostics only. Disconnect when done. Before you can access the USB user interface, you must install the RBUS1CP.inf file, or have RPS version 5.16 or greater installed, and USB driver on the target PC or laptop. The RBUS1CP.inf file and USB driver are available on the supplied CD ROM. You need to install this file only once on the target PC or laptop F.01U Installation and Operation Guide Bosch Security Systems, Inc.

27 Conettix Plug-in Communicator Configuration en 27 If you currently have RPS version 5.16 or greater, you do not have to install USB driver (RBUS1CP.inf) as described below. If the B450 CD-ROM is not available: 1. From your Internet browser, go to: to open the Bosch Web site. 2. Select the web site for your region and country. 3. In the Online Catalogs section on the left, click the Intrusion Alarm Systems link. 4. Under the Intrusion Alarm Systems Products heading, scroll to the Conettix - Information Transport Solutions section. Click the Show product section link. 5. Click the Conettix IP link. 6. Scroll to the B450 Plug-in Communicator section. Click the section title to open the product page. 7. Under the product image, click the Software tab. 8. Click OK to accept the license agreement. 9. To the right of the B450, click on the language link (for example, en). The File Download dialog box opens. 10. Click Save to save the file to the target PC or laptop. Perform this task to download both the USB driver file, and the RBUS1CP.inf file. 11. Supply power to the B Connect the B450 to the target PC or laptop, using a USB Type A to A cable. A New Hardware Found window appears on the computer. 13. Install the RBUS1CP.inf file onto your PC or laptop. Verify through the device manager that the appropriate.inf installs properly, and is listed under the Ports (COMM & LPT) section. The correct.inf file is B450 Config. 14. Install a communication program to configure the B450. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

28 28 en Configuration Conettix Plug-in Communicator Figure 5.5: RBUS1CP.inf installed inside Device Manager Install a communication program To use USB connection from a computer to the B450 to configure the B450, you must use a communication program. Windows XP. The Microsoft Windows XP installation automatically installs HyperTerminal, a Microsoft communication program, when Windows installs. If HyperTerminal is not installed, install it from the Windows XP installation disc, or install Tera Term from the B450 CD. Windows Vista and Windows 7/8 installations no longer include a communication program when the operating system installs. Install Tera Term from the B450 CD. Install the communication program that supports your configuration (Hyper Terminal or Tera Term), depending on your laptop or PC s operating system. Tera Term is preferred in all applications as its operation is understood by Bosch Technical Support if assistance is required. Installing Tera Term When you perform the Tera Term installation, follow the prompts in the installation wizard, but on the Select Components page of the wizard, select Compact installation from the dropdown list. Refer to the figure below F.01U Installation and Operation Guide Bosch Security Systems, Inc.

29 Conettix Plug-in Communicator Configuration en 29 Figure 5.6: Setup - Tera Term wizard's Select Components window Tera Term version interface After installing the latest Tera Term version, double-click on Tera Term to launch the program. The Tera Term window opens. Refer to the illustrations below to set up Tera Term defaults. Setting up Tera Term defaults: 1. Launch the application. 2. Select Setup => Terminal as shown below. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

30 30 en Configuration Conettix Plug-in Communicator Figure 5.7: Selecting the Terminal Setup window 3. Change the default setting of CR to LF from the Receive pull-down menu and press OK. Figure 5.8: Changing the Receive: option to LF 4. Select Save setup F.01U Installation and Operation Guide Bosch Security Systems, Inc.

31 Conettix Plug-in Communicator Configuration en 31 Figure 5.9: Saving the setup 5. Select Save to overwrite the existing TERETERM.INI file. This stores the new setting, and allows you to have the correct display settings when you launch Tera Term in future sessions. 6. Select the correct port option in the Port: pull-down menu for the B450. Figure 5.10: Tera Term Pro window shown Bosch Security Systems, Inc. Installation and Operation Guide F.01U

32 32 en Configuration Conettix Plug-in Communicator Log into the USB interface To allow for USB configuration, address switch must be set to 0. Powering down the module after changing the bus address switch for programming is not required. 1. Ensure that the USB-Type A male-to-male cable is connected to the B450 and the target PC or laptop. 2. From Windows, start a terminal session by launching Hyper Terminal on Windows XP or earlier, or launching Tera Term on Windows Vista/Windows 7/Windows Set up a connection on the new virtual serial COM port (for example, Port: COM7: B450 [COM7]). If the B450 is not connected to the computer, or the USB driver is not installed, the B450 does not appear in the list. 4. After the connection is established, press [Enter]. The B450 USB login window opens. Figure 5.11: B450 USB login window 5. Enter the password to log on. The default password is B450. The user interface allows three attempts to enter the password correctly. After three failed attempts, the B450 shows a Too many attempts error message, and the USB interface enters into an idle state for 30 sec. Repeat Steps 3 through 6. at the conclusion of 30 sec. 6. Press [Enter] to continue. The USB main menu opens F.01U Installation and Operation Guide Bosch Security Systems, Inc.

33 Conettix Plug-in Communicator Configuration en 33 The default password is case-sensitive. Verify the password for case-sensitivity when entering. Menu access disabled error message Refer to USB menu access disabled, page 56 if you receive the following error message when accessing the USB menu. Figure 5.12: USB menu access disabled error window Bosch Security Systems, Inc. Installation and Operation Guide F.01U

34 34 en Configuration Conettix Plug-in Communicator USB Main menu 1 2 : 3 4 Figure 5.13: USB Main Menu Callout Description 1 Installed device 2 Current device status 3 Current access level 4 Main menu options The USB main menu appears: after a user enters a password successfully every time the user presses [Enter] without first selecting an option from the main screen upon returning from a sub-menu. The following table describes the USB Main Menu parameters found within callouts 1-3 in the graphic above.: Parameter B44x Description This field displays one of the following parameters: B44x Cellular Communicator Plug-in not connected Detecting plug-in module F.01U Installation and Operation Guide Bosch Security Systems, Inc.

35 Conettix Plug-in Communicator Configuration en 35 Link Status Bus Status Module Status Tamper Access Level This field displays the connection status to the cellular network. The options include: OK Error This option includes: On Line Not Connected This option includes: Normal Trouble This option includes: Yes No Disabled (through configuration) This option includes: Restricted Full Table 5.3: USB Menu parameters USB menu structure The following illustration depicts the B450 menu structure. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

36 36 en Configuration Conettix Plug-in Communicator Main Menu Status (Starts with Basic Status) 1 0 Go to Main Menu 1 Go to Basic Status Menu 2 Go to Advanced Status Menu 3 Reset Statistics 4 Signal Strength 5 Product Versions Change Passcode 2 Basic Configuration Advanced Configuration 4 Reset to Factory Defaults 5 Diagnostic Log* 6 Firmware Update Basic Configuration Menu 0 Go to Main Menu 1 Network Access Point Name (APN) 1 TCP/UDP port 2 Network Access Point User Name 2 AES Encryption 3 Network Access Point Password 3 Tamper Enabled 4 SIM PIN 4 Panel Programming Enabled 5 Session Keep Alive Period (min) 5 Inbound SMS Enabled 6 Inactivity Timeout (min) 6 Reporting Delay for Low Signal Strength 7 GSM/GPRS Configuration 8 Server Configuration 0 Basic Configuration Menu 1 Server Name/Address 0 Go to Main Menu 1 Set Primary DNS Server Address 2 Set Alternate DNS Server Address 3 Set Modem Reset Count 4 Set Reporting Delay for no towers 5 Set Reporting Delay for single tower 6 Set TCP Keepalive Time 7 Set TLS Automation Security 0 Go to Main Menu 1 Modify diagnostic settings 2 Re-print all console messages 3 Enable console messages 2 Server Port Number 3 Server Authentication/Encryption 4 Authentication User Name 5 Authentication Password 0 Go to Diagnostic Log Menu 1 Cellular Modem Verbose Mode 2 Bus Communication Verbose Mode 3 Network Communications Verbose Mode 4 Network Operations Verbose Mode 5 Module Operations Verbose Mode 6 All Verbose Modes Off Exit 8 * The Diagnostic Log option is used in troubleshooting communication issues with the B450. Use of the Diagnostic Log option is to be used only at the direction of TECHNICAL SUPPORT. Figure 5.14: USB menu structure Changes or edits to programming are discarded if you select the Exit option, and exit the menu. If you make changes or edits, select the Save and Exit option to ensure programming changes are saved USB menu For a description of the USB menu options, refer to the tables in the following sections. To go to a specific menu option, enter the appropriate menu option number. Any and all changes that were not saved will be lost if no keys are pressed within 5 minutes. The USB menu will automatically logout. Using the Escape (Esc) key Press the Escape (Esc) key without making any programming changes will return you to the previous menu. USB Main Menu Pressing the Escape key after entering data will clear data entered F.01U Installation and Operation Guide Bosch Security Systems, Inc.

37 Conettix Plug-in Communicator Configuration en 37 Option Press to Select Description 1. Status (Starts with Basic Status) 2. Change Passcode 3. Basic Configuration 4. Advanced Configuration 5. Reset to Factory Defaults 1 To access and view the link, modem, and bus status For additional menu descriptions, refer to the USB Status sub-menu parameters table below for more information. 2 To change the login passcode, enter the new passcode twice. The second entry confirms the new passcode. Passcodes must be 4-10 characters long, and are case-sensitive. 0-9, A-Z, a-z, and special characters are allowed. If SMS configuration is used, do not use semicolon (;) or exclaimation mark (!) as part of the passcode. 3 Select to program Basic Configuration options. Press 0 to return to the Main menu. To change a basic parameter, select the option to change, and then enter in the new value. 4 Select to program Advanced Configuration options. Press 0 to return to the Main menu. To change an advanced parameter, select the option to change, and then enter in the new value. 5 Select to reset all factory default values. All fields are cleared and the factory default values are restored. A non-defaulted SDI2 control panel will overwrite the default settings if connected to the defaulted module. 6. Diagnostic Log 6 Select to review the Diagnostic log. 7. Firmware Update 7 Select this option to update the firmware in the B450. Download your update file from the Bosch website prior to performing an update. For more information on Firmware update workflows, refer to Firmware Update page, page Exit 8 Select to exit the menu and log out. You must enter the passcode to log back in. If configuration changes have been made but not saved, you will be prompted to save or discard them. Table 5.4: USB Main Menu parameters Basic Status Menu The following section describes the description of the Basic Status menu parameters. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

38 38 en Configuration Conettix Plug-in Communicator Figure 5.15: Basic Status screen Parameter Description Link Status IP Address Link Status Encryption Socket xx: Port Number This field displays the current Cellular Network IP Address. An IP address of is listed when no IP address is found. This field displays the connection status to the cellular network. This field displays either OK, or Error. This field displays either Normal, or Trouble: This field displays the current open Port Numbers and Data Types (up to 32). Modem Status The information below displays in the appropriate fields. If no modem status is detected, the following message appears: Modem status is not available. Telephone Number Electrical Serial # (ESN) This field displays the cellular phone number if available. A phone number of is listed when there is no phone number. This field displays the B44x radio modem serial number F.01U Installation and Operation Guide Bosch Security Systems, Inc.

39 Conettix Plug-in Communicator Configuration en 39 Data Status Signal Strength This field displays one of the following; Disconnected, Connecting, or Connected. This field displays the current signal strength. One of the following appears; Very good, Good, Marginal, Unacceptable, or Unavailable. Bus Status Bus Type Bus Address Bus Voltage This field displays the current bus type. One of the following appears; SDI2, SDI, Option, or None. This field displays the current bus address. One of the following appears; 1, 2, 88, 92, 134, or 250. This field displays the current voltage. One of the following appears; Good, or Low. Module Status This status displays only if there is a trouble condition. B44x Plug-in Missing Detecting Plug-in B44x Plug-in Missing B44x Plug-in Invalid No IP Address Detecting Plug-in Signal Strength Low Too Few Towers No Towers B44x Not Active B44x Failure Configuration Failure Low Bus Voltage No Bus Communication Switch in Position 0 Firmware Checksum Error Configuration Checksum Error SIM Missing SIM PIN Wrong SIM PIN Lockout Invalid Access Point No IP Address Advanced Status Menu The following section describes the description of the Advanced Status menu parameters. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

40 40 en Configuration Conettix Plug-in Communicator Figure 5.16: Advanced Status screen Parameter Description Advanced Link Status Internet (ping) IPv4 DNS Server IP Address Alternate IPv4 DNS Server IP Address DNS Status UDP Packets Transmitted UDP Packets Received This field displays one of the following; OK, Error, No Status (no ping has been performed). This field displays the current IP sddress. This field displays an alternate IP address. This field displays one of the following; OK, Error, No Status (no DNS lookup (has been performed). This field displays from power up, or Option 3 (Reset Status) This field displays from power up, or Option 3 (Reset Status) F.01U Installation and Operation Guide Bosch Security Systems, Inc.

41 Conettix Plug-in Communicator Configuration en 41 Advanced Modem Status Transceiver Model number Carrier Name Data Status Signal Strength Towers Available Base Station ID Current Band Data Class Temperature This field displays one of the following; DE910-DUAL, CE910-DUAL, GE910-QUAD This field displays the carrier network providing service. This field displays one of the following; Disconnected, Connecting, or Connected. This field displays the current signal strength in dbm. This field displays the number of towers that can be detected by the module This field displays information about the tower you are currently connected to. This field displays the current band frequency This field displays one of the following; 1xRTT, 3G, GPRS, EDGE, WCDMA, HSPA This field displays the internal temperature of the radio transceiver (in Celsius) Advanced Bus Status Bus Voltage Bus Commands received This field displays the voltage measured at the input to the module This is a running total of the number of valid bus messages that the module has received. If the module is on the bus and operating this number will change when refreshed. For a description of the Status sub-menu parameters, refer to the table below. To go to a specific Status menu option (Reset Status, Signal Strength, and Product Versions), perform the following; 1. Enter the B450 passcode 2. Press [1] Status (Starts With Basic Status). 3. Select the desired parameter (Basic Status, Advanced Status, Reset Status, Signal Strength, and Product Versions) from the table below. Option Press to Select Description 1. Basic Status Menu 2. Advanced Status Menu 1 This option displays the current IP address, link status, modem status, bus status, and module status. 2 This option displays various parameters related to the cellular device such as UDP packets transmitted and received, the carrier name, available towers, and data class, just to name a few. 3. Reset Status 3 The status display shows several items that are counts of activities, such as UDP packets transmitted. When reset status is selected, all counts are returned to zero. This is not required for normal operation. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

42 42 en Configuration Conettix Plug-in Communicator Option Press to Select Description 4. Signal Strength 4 The current signal strength records every 15 minutes for up to 48 hours worth of data. When signal strength is selected, up to 192 values are displayed representing the signal strength values over the last 48 hours. If the B450 has been powered up less than 48 hours, the list shows only the samples taken so far. If it has been less than 15 minutes, you will see Not Available listed. The screen shot below is an example of what you might see in the signal strength history. 5. Product Versions 5 This option displays the software version of all entities in the B450. The following list is an example of the versions displayed: *** Product Versions *** B450 Product ID: B450 Application: V B450 Boot Loader: V B450 Hardware: V RTOS: V Fusion Stack: V Cellular Manager: V UPKI Encryption: V AES Lib: V Modem Firmware: V Table 5.5: Status sub-menu parameters Basic Configuration sub-menu parameters TCP/UDP Port Number This option sets the source port for the B450. To go to TCP/UDP Port Number, perform the following: 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [1] TCP/UDP Port Number. 4. Enter the desired port number value. Basic Configuration sub-menu parameters AES Encryption This option allows each receiver path to be configured with a unique AES encryption key. Refer to the graphic below for entering in the encryption key F.01U Installation and Operation Guide Bosch Security Systems, Inc.

43 Conettix Plug-in Communicator Configuration en 43 Figure 5.17: Entering the encryption key Enter in your 32 digit encryption key. Verify your 32 digit key does not exceed the arrow prompt as viewed in the graphic above. The module says "Invalid Entry: Incorrect key length", if you enter more or less then the required key length. It also detects that you entered hex values 0-9 and A-F. Any other hex values result in an error. To go to AES Encryption, perform the following: 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [2] AES Encryption. 4. Enter the desired option: 0 = Go to Basic Configuration Menu 1 = Disabled 2 = 128 Bits 3 = 192 Bits 4 = 256 Bits Basic Configuration sub-menu parameters Module Enclosure Tamper This option sets the enclosure tamper indication of a particular SDI2 device when enabled. To go to Module Enclosure Tamper, perform the following: 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [3] Module Enclosure Tamper. 4. Enter the desired option. Basic Configuration sub-menu parameters Panel Programming This option sets the enables/disabled configuration of the B450 by the control panel. To go to Panel Programming, perform the following: Bosch Security Systems, Inc. Installation and Operation Guide F.01U

44 44 en Configuration Conettix Plug-in Communicator 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [4] Panel Programming. 4. Enter the desired option. Basic Configuration sub-menu parameters Inbound SMS This option allows the B450 to be configured via SMS configuration. To go to Inbound SMS, perform the following: 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [5] Inbound SMS. 4. Enter the desired option. Basic Configuration sub-menu parameters Reporting Delay for Low Signal Strength This option sets the duration of time when the B450 s signal strength is measured. To go to Reporting Delay for Low Signal Strength, perform the following: 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [6] Reporting Delay for Low Signal Strength. 4. Enter the desired option. The range is from 0 to Then press Enter. Basic Configuration sub-menu parameters GSM/GPRS Configuration For a description of the Basic Configuration sub-menu parameters (Access Point Name, Access Point Login Name, Access Point Login Password, or SIM PIN), refer to the table below. To go to a specific Basic Configuration menu option GSM/GPRS Configuration (Access Point Name, Access Point Login Name, Access Point Login Password, or SIM PIN), perform the following: 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [7] GSM/GPRS Configuration. 4. Select the desired parameter (Network Access Point Name, Network Access Point User Name, Network Access Point Password, or SIM PIN) from the table below. Option Press to Select Description 1.Network Access Point Name (APN) 2. Network Access Point User Name 1 The Network Access Point Name is required for modems that use a SIM card such as the B442 or B443. The Network Access Point Name must be 0-99 characters long, and is case sensitive. The default is: wyless.apn 2 The Network Access Point User Name is used on the B442 and B443. The Network Access Point User Name allows users to connect to the access point. The Network Access Point User Name must be 0-30 characters long, and is case sensitive. The default is: None F.01U Installation and Operation Guide Bosch Security Systems, Inc.

45 Conettix Plug-in Communicator Configuration en 45 Option Press to Select Description 3. Network Access Point Password 3 The Network Access Point Password is used on the B442 and B443 Some carriers require a password to access the Access point. The Network Access Point Password must be 0-30 characters long, and is case sensitive. The default is: None 4. SIM PIN 4 To set the PIN in the B450 to match the SIM card pin in the cellular communicator module (for B442 and B443 only) To erase text, you must type in the word None to erase the previous text. This is NOT case-sensitive. The default is None: 5. Session Keep Alive Period (min) 6. Inactivity Timeout 5 This parameter sets the length of time in minutes between session keep alive reports to verify that an idle connection is still active. Leave the default value. The default is: 0 The range is 0 to 1000 minutes 6 This parameter specifies the time before the control panel will disconnect a session with no data traffic. Leave the default value. When enabled, the control panel verifies an active connection exists with the module. When disabled, the control panel does not verify the connection is active. The default is: 0 The range is 0 to 1000 minutes Basic Configuration sub-menu parameters Server Configuration For a description of the Basic Configuration sub-menu parameters Server Configuration ( Server Name/Address, Server Port Number, Server Authentication/Encryption, Authentication User Name, or Authentication Password), refer to the table below. To go to a specific Basic Configuration menu option ( Server Name/Address, Server Port Number, Server Authentication/Encryption, Authentication User Name, or Authentication Password), perform the following: 1. Enter the B450 passcode 2. Press [3] Basic Configuration. 3. Press [8] Server Configuration. 4. Select the desired parameter ( Server Name/Address, Server Port Number, Server Authentication/Encryption, Authentication User Name, or Authentication Password from the table below. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

46 46 en Configuration Conettix Plug-in Communicator Option Press to Select Description 1. Server Name/Address 2. Server Port Number 3. Server Authentication/ Encryption 4. Authentication User Name 5. Authentication Password 1 This parameter specifies either the name or the address of the SMTP (Simple Mail Transfer Protocol) for the server chosen to transfer event messages from the control panel to a designated address. (Example:smtp.gmail.com) 2 This parameter specifies the port number for the server. The default is: 25 3 Use this parameter to set the security level required by the server to receive messages from the control panel. Authentication means that the server requires an authentication username and authentication password. This is sometimes referred to as SMTP-AUTH. The Encryption used is Transport Layer Security (TLS) The default is: Authenticate 4 This parameter specifies the user name for the account that is set up to receive messages from the SMPT server sent by the control panel. The default is: None Range is: ASCII printable characters 5 This parameter sets the password that the SMPT server uses to send s to the Personal Notification destinations. The default is: None Range is: 0 49 ASCII printable characters Diagnostic Log sub-menu parameters For a description of the Diagnostic Log sub-menu parameters (Modify Diagnostic Settings, Reprint All Console Messages, and Enable Console Messages), refer to the table below. The Diagnostic Log option is used in troubleshooting communication issues with the B450. Use of the Diagnostic Log option is to be used only at the direction of TECHNICAL SUPPORT. Refer to Diagnostic log, page 60 for more information. To go to a specific Diagnostic Log menu option (Modify Diagnostic Settings, Re-print All Console Messages, and Enable Console Messages), perform the following: 1. Enter the B450 passcode 2. Press [6] Diagnostic Log. 3. Sect the desired parameter (Modify Diagnostic Settings, Re-print All Console Messages, and Enable Console Messages) from the table below F.01U Installation and Operation Guide Bosch Security Systems, Inc.

47 Conettix Plug-in Communicator Configuration en 47 Option Press to Select Description 1. Modify Diagnostic Settings 2. Re-print Saved Console Message 3. Enable Live Console Messages 1 The Diagnostic logging is intended for use only under Bosch direction. Diagnostic settings determine which types of messages to display. 2 The Re-Print Saved option prints any diagnostic messages that have already occurred and are stored in the B450 s buffer. This can print what just happened if an issue occurs. 3 Enable live console messages provides real time output of diagnostic messages. This allows the PC running TeraTerm to log what is occurring in the module and can log for longer periods of time. Table 5.6: Diagnostic Log sub-menu parameters SMS and USB configuration parameters The table below shows all parameters available through SMS or USB configuration. Values in bold are default settings. ID Parameter Values Description 1 Current Password 4 to 10 characters (B450) Mandatory and case sensitive. Make sure you record and record your password. 2 New Password 4 to 10 characters New password, as desired. Case sensitive. 13 TCP/UDP Port Number 1 to (7700) Sets the source port for the B AES Encryption 0 = Disabled 1 = 128 bit, 2 = 192 bit, 3 = 256 bit 16 AES Encryption Key 32, 48, or 64 digits max. 0-9, A-F, a-f allowed Security encryption on or off. The setting must match the encryption settings in the receiver. This setting applies to SDI, and GV4 v1.0.x control panels only. The AES Encryption Key must match the encryption key in the receiver. This setting applies to SDI, and GV4 v1.0.x control panels only. 19 Module Enclosure Tamper (for GV4 v1.0.x control panels) 0 = Disabled 1 = Enabled When enabled, allows tamper and tamper restore conditions to be reported to an SDI2 control panel. Only control panels with a SDI2 bus connection to the B450 can report a tamper condition. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

48 48 en Configuration Conettix Plug-in Communicator ID Parameter Values Description 20 Inbound SMS 0 = Disabled 1 = Enabled Allows the B450 to be configured via SMS configuration. When this option is set to Disabled, no inbound SMS text messages are processed. 65 IPv4 DNS Server IP Address 66 Alternate IPv4 DNS Server IP Address IPv4 address format ( ) IPv4 address format ( ) The B450 uses the DNS server addresses supplied by the cellular network when the Primary DNS Server address option is configured as If the address is not configured as , the B450 installs the Primary DNS Server address. If the address is not configured at , the B450 installs the Alternate DNS Server address. 67 Panel Programming 0 = Disabled 1 = Enabled Select to enable or disable control panel programming. This enables/disabled configuration of the B450 by the control panel. 68 Reporting Delay for Low Signal Strength 69 Reporting Delay for No Towers 70 Reporting Delay for Single Tower sec. (1800) Sets the duration of time when the B450 s signal strength is measured. The value selected determines how long the signal strength must be at a low condition before reporting as low, or how long the signal strength must be normal before reporting as normal sec. (1800) Amount of delay before the module reports a trouble for not being able to receive signals from a cell tower sec. (0) Amount of time delay before module reports a trouble due to getting signals from only one tower instead of multiple towers. 71 Modem Reset Count 0 99 communication attempts (5) This parameter determines how many times a packet of data must be sent without a reply before the cell module modem is reset to attempt restoring communications. Note: When connected to a B5512/B4512 or D9412GV4/D7412GV4 control panel at v2.03 or higher, the default is zero and controlled by the above mentioned control panel, unless control panel programming is disabled. 72 TCP Keep Alive Time sec (45) This parameter determines how long to wait between transmissions to keep an idle TCP connection to a remote host from terminating due to inactivity. Table 5.7: SMS and USB configuration parameters F.01U Installation and Operation Guide Bosch Security Systems, Inc.

49 Conettix Plug-in Communicator Configuration en Short Message Service (SMS) configuration The B450 supports configuration by SMS connection. When enabled via the Inbound SMS parameter, the Short Message Service feature allows an installer to configure the B450 through the use of a mobile phone, or any other service that sends compatible SMS text messages. SMS text messages are not processed when the Inbound SMS parameter is set to: Disabled. The default setting is Enabled Use SMS to configure the B450 The SMS string follows a specific format. If the configuration message exceeds 160 characters, you must send multiple messages. Refer to Compose the Configuration SMS for more details. When the B450 receives the final valid part of an SMS message, it accepts the configuration. To allow the receipt of SMS data, the bus address switch must be set at position 0. Refer to the tables in this section for LED activity. If the bus address switch is not set to 0, incoming SMS data is discarded. Enter CONFIG MODE Ensure that the bus address switch is set to 0. Compose the Inbound SMS Use the appropriate SMS template for the selected mode of operation, and compose the configuration SMS message on your mobile phone. SMS can contain only 160 characters. Refer to Multiple SMS Messages (for Messages Longer than 160 Characters) for instructions for sending a multiple SMS configuration. The information in the tables below contain only the essential configuration IDs. For additional configuration IDs, refer to the SMS configuration parameters. To configure a B450 parameter using SMS text, format the text as follows : %1;1=B450;19=1;! The configuration message must begin with the sequence number (%1) and must include the current B450 configuration password (default = B450) followed by the ID number and the value you want to set. Separate each ID or value pair with a semi-colon ; (for example, %1;1=B450;19=1;!). To allow spanning of configuration across multiple messages, each SMS starts with the sequence number followed by the command line separator. Use the! character to signal the end of the configuration data. Refer to your cellular phone s documentation for available characters. You must include the current SMS configuration passcode in the SMS text message to allow the module to save the new configuration data. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

50 50 en Configuration Conettix Plug-in Communicator Removing parameter text In order to remove text from an SMS message, you must use the word None, or ;. For instance, if you want to remove a SIM PIN using SMS, you would include either: 4=None or 4=; in the text message. The word None is NOT case sensitive. SMS configuration parameters ID Description 1= Current passcode (4 to 10 characters); default = B450 2= New passcode (4 to 10 characters) 4= SIM PIN (4 to 8 characters) Basic parameters 10= Network Access Point Name (APN): Text characters that can fit in a single text message 11= Network Access Point User Name (up to 30 characters) 12= Network Access Point Password (up to 30 characters) 13= TCP/UDP port number: 7700 (1 to 65535) 15= AES encryption 0 = disable 1 = 128 bit 2 = 192 bit 3 = 256 bit 16= AES encryption key (0 to 9, A-F, a-f, based on key size, none, 32, 48, or 64 digits) 19= Module Enclosure Tamper (V1.0.x control panels on SDI2 bus) 0 = disable 1 = enabled 20= Inbound SMS 0 = disabled 1 = enabled Advanced parameters 57= Session Keep Alive (0 to 1000 min) 58= Inactivity timeout (0 to 1000 min) 65= IPv4 DNS Server IP Address F.01U Installation and Operation Guide Bosch Security Systems, Inc.

51 Conettix Plug-in Communicator Configuration en 51 ID Description 66= Alternate IPv4 DNS Server IP Address 67= Panel programming 0 = disabled 1 = enabled 68= Reporting delay for low signal strength ( sec) 69= Reporting delay for no towers ( sec) 71= Modem reset count (0 99) 72= TCP keep alive time (0 255 sec) Table 5.8: SMS configuration parameters Multiple SMS Messages (for Messages Longer than 160 Characters) ID Description Sample SMS 1 %1; SMS sequence number 1 %1;1=B450;2=secret123;15=3; 1=B450; Current password 16= ; 2=secret123; New password (case sensitive) 15=3; Enable AES encryption 16= ; Sample AES key 1 As you enter in the various ID s into your cell phone, do not press the return key. Doing so will cause the B450 to ignore the programming request. Table 5.9: Double SMS example, part 1 ID Description Sample SMS 2 %2; SMS sequence number %2;19=1;! 19=1; Tamper enabled! End of configuration 2 When you end the configuration programming with the exclamation mark, do not enter any values. Doing so may cause the B450 to ignore the programming request. Table 5.10: Double SMS example, part 2 Send the Inbound SMS 1. Send the configuration SMS to the B44x module s phone number. The transmission might take several minutes. Because the bus address switch is set to 0, the B450 waits for an SMS until a message is received. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

52 52 en Configuration Conettix Plug-in Communicator 2. Observe the LEDs on the B450. When the Transmit (TX) and Receive (RX) LEDs will flash in unison at a 1 second interval indicating a successful SMS was received. If the SMS was received but was not valid the Transmit (TX) and Receive (RX) LEDs will alternate flashing at 1/2 second interval. Both flashing patterns will continue until the bus address switch is moved from position "0. If the LEDs indicate an invalid SMS, repeat the steps in Enter CONFIG MODE. Refer to the tables in Maintenance and troubleshooting, page 56 section for more information on LED descriptions. Ensure that your configuration SMS contains the correct information, as well as sending the SMS to the correct phone number for the module, or use the USB connection to configure the B450 Exit from CONFIG MODE 1. Change the bus address switch to the desired value, depending on the supported control panel. Changes to the B450 configuration are accepted. 2. Check the signal strength and Heartbeat LED for status. 5.4 Firmware Update page Firmware updates are performed through the USB interface via a communication program such as Hyper Terminal or Tera Term. When performing a firmware update, verify that the update software file to be downloaded is the most current software update version. No changes to the firmware occur if the firmware update version is the same version as the current version installed on the B Ensure that the USB cable is connected to the B450 and the target PC or laptop. 2. From Windows, start a terminal session by launching Hyper Terminal on Windows XP or earlier, or launching Tera Term on Windows Vista/Windows 7/Windows Log into the USB interface as described in Log into the USB interface, page 32, starting at step 3, and continuing through to step 6. The B450 USB login window appears, listing the current software version and build F.01U Installation and Operation Guide Bosch Security Systems, Inc.

53 Conettix Plug-in Communicator Configuration en 53 Figure 5.18: B450 USB login window 4. Select option 7 Firmware Update and press [Enter]. Once the Firmware Update menu item is selected, the B450 begins a 90 sec timer as it waits for the firmware File>Transfer>XMODEM>Send process to begin. If the transfer process takes longer than 90 sec to locate the file and begin the send process, the menu times out, and the user must begin the update process again. 1. From the Tera Term main menu, select File>Transfer>XMODEM>Send. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

54 54 en Configuration Conettix Plug-in Communicator Figure 5.19: Firmware update send window 2. In the XMODEM Send dialog window, navigate to the folder location and select the firmware update software you downloaded. The file ends in *.kfw extension. Figure 5.20: File navigation F.01U Installation and Operation Guide Bosch Security Systems, Inc.

55 Conettix Plug-in Communicator Configuration en Click Open to start the firmware update. The Tera Term: XMODEM Send dialog box opens and indicates the update process. Figure 5.21: Tera Term XMODEM Send dialog box 4. When the file transfer completes, the Tera Term: XMODEM Send dialog box closes automatically. Within the Tera Term window an updating to firmware version x.xx.xxx message displays, and the B450 automatically reboots. 5. Close the Tera Term session, and re-launch Tera Term. 6. Log back into Tera Term as described previously to re-establish communication from your laptop, to the B450. Communication between the control panel and B450 is restored. Bosch Security Systems, Inc. Installation and Operation Guide F.01U

56 56 en Maintenance and troubleshooting Conettix Plug-in Communicator 6 Maintenance and troubleshooting Refer to the following for maintenance and troubleshooting information 6.1 USB menu access disabled A Menu access disabled error message occurs when the Web/USB Access Enabled feature in RPS is set to No when connected to a GV4 Series v2.03+ or B Series v2.03+ control panel. Perform the following to enable the feature: 1. Launch your session of RPS. 2. Login to RPS. 3. Select the correct control panel. 4. Select SDI2 MODULES. 5. Select IP Communicator. 6. Double-click on Web/USB Access Enable, and select Yes. This allows you to view or change information from the B450 USB menu. Figure 6.1: USB access enable 6.2 LED status indicators When the tamper input is shorted, the firmware version flashes, then the B450 LEDs are disabled to conserve power. To see the troubleshooting LEDs, open the tamper circuit or jumper The B450 includes the following on-board LEDs to assist with troubleshooting: Heartbeat (system status). RX (receive). TX (transmit). The plug-in module also includes LEDs for troubleshooting and status F.01U Installation and Operation Guide Bosch Security Systems, Inc.

Conettix Plug-in Communicator Interface

Conettix Plug-in Communicator Interface Conettix Plug-in Communicator B450 en Installation and Operation Guide Conettix Plug-in Communicator Table of Contents en 3 Table of contents 1 Safety 4 2 Introduction 5 2.1 About documentation 5 2.2

More information

Conettix Plug-in Communicator Interfaces B450

Conettix Plug-in Communicator Interfaces B450 Conettix Plug-in Communicator Interfaces B450 en Installation and Operation Guide Conettix Plug-in Communicator Interfaces Table of contents en 3 Table of contents 1 Safety 4 2 Introduction 5 2.1 About

More information

GPRS/GSM IP Communicator Conettix ITS-DX4020-G. Installation and Operation Guide

GPRS/GSM IP Communicator Conettix ITS-DX4020-G. Installation and Operation Guide GPRS/GSM IP Communicator Conettix ITS-D4020-G en Installation and Operation Guide GPRS/GSM IP Communicator Table of Contents en 3 Table of Contents 1 Introduction 5 1.1 Trademarks 5 1.2 Technical Specifications

More information

Control Panels B5512/B4512. en UL Installation Instructions

Control Panels B5512/B4512. en UL Installation Instructions Control Panels B551/B451 en UL Installation Instructions Control Panels Table of Contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.1.1 Related documentation 4 1. Bosch Security

More information

Conettix Plug-in Communicator Interface

Conettix Plug-in Communicator Interface Conettix Plug-in Communicator Interface B450 en Release Notes Conettix Plug-in Communicator Interface Table of Contents en 3 Table of contents 1 Introduction 4 1.1 Requirements 4 1.2 About documentation

More information

Intrusion Control Panels Quick Guide. May 2015

Intrusion Control Panels Quick Guide. May 2015 Intrusion Control Panels Quick Guide May 2015 Control Panels B Series Commercial Type Number B3512 B4512 B5512 Applications Type Residential, Small Commercial Residential, Small Commercial Residential,

More information

ICP-SDI Installation Instructions. SDI Splitter

ICP-SDI Installation Instructions. SDI Splitter ICP-SDI-9114 EN Installation Instructions SDI Splitter ICP-SDI-9114 Installation Instructions Listings and Approvals Listings and Approvals UL UL 65 Police Station Burglar Alarm Units and Systems UL 609

More information

Control Panel. D9412GV4/D7412GV4/D7212GV4 v1.xx. Release Notes

Control Panel. D9412GV4/D7412GV4/D7212GV4 v1.xx. Release Notes Control Panel D9412GV4/D7412GV4/D7212GV4 v1.xx en Release Notes Control Panel Table of contents en 3 Table of contents 1 Introduction 4 1.1 About documentation 4 1.1.1 Bosch Security Systems, Inc. product

More information

Remote Programming Software LITE (RPS LITE)

Remote Programming Software LITE (RPS LITE) Remote Programming Software LITE (RPS LITE) D5500CU LITE, v6.06.016 en Release Notes Remote Programming Software LITE (RPS-LITE) Introduction en 3 1 Introduction RPS-LITE version 6.06.016 Release Notes.

More information

D1265. Installation Guide. Touchscreen Keypad

D1265. Installation Guide. Touchscreen Keypad D1265 EN Installation Guide Touchscreen Keypad D1265 Installation Guide 1.0 Introduction Contents 1.0 Introduction...3 1.1 Overview...3 1.2 Graphical Buttons...3 1.3 Audible Tones...4 1.4 Supervision...4

More information

Remote Programming Software LITE (RPS-LITE) D5500CU-LITE, v6.05

Remote Programming Software LITE (RPS-LITE) D5500CU-LITE, v6.05 Remote Programming Software LITE (RPS-LITE) D5500CU-LITE, v6.05 en Release Notes Remote Programming Software LITE (RPS-LITE) Introduction en 3 1 Introduction RPS-LITE version 6.05 Release Notes Remote

More information

DX4020. Installation Guide. Network Interface Module

DX4020. Installation Guide. Network Interface Module DX4020 EN Installation Guide Network Interface Module DX4020 Installation Guide EN 2 Trademarks Microsoft - and Windows are either registered trademarks or trademarks of Microsoft Corporation in the United

More information

Remote Programming Software (RPS-LITE)

Remote Programming Software (RPS-LITE) Remote Programming Software (RPS- D5500CU-LITE en Release Notes Remote Programming Software (RPS- Introduction en 3 1 Introduction Copyright This document is the intellectual property of Bosch Security

More information

FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW

FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW en Installation manual FPA-1000-V2 Network Cards Table of contents en 3 Table of contents 1 General Information 4 1.1 Safety 4 1.2 Network

More information

Conettix ITS-D6682-UL

Conettix ITS-D6682-UL Conettix ITS-D6682-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6682-UL Installation Guide Contents Contents 1.0 Introduction...3 1.1 Network Interface... 3 1.2 Serial Interface... 3

More information

Quick Installation Guide

Quick Installation Guide Quick Installation Guide DL-200 Cellular Data logger V1.2_201610 TABLE OF CONTENTS CHAPTER 1 INTRODUCTION... 4 1.1 CONTENTS LIST... 5 1.2 HARDWARE INSTALLATION... 6 1.2.1 WARNING... 6 1.2.2 SYSTEM REQUIREMENTS...

More information

Conettix ITS-D6686-UL PRELIMINARY. Installation Guide. Ethernet Network Adapter

Conettix ITS-D6686-UL PRELIMINARY. Installation Guide. Ethernet Network Adapter Conettix ITS-D6686-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-UL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...

More information

Conettix ITS-D6686-UL

Conettix ITS-D6686-UL Conettix ITS-D6686-UL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-UL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...

More information

Conettix Ethernet Communication Module

Conettix Ethernet Communication Module Conettix Ethernet Communication B426 en Release Notes Conettix Ethernet Communication Table of Contents en 3 Table of contents 1 Introduction 4 1.1 Requirements 4 1.2 About documentation 5 2 Version 3.05

More information

EA500. Installation Instructions Transponder

EA500. Installation Instructions Transponder EA500 EN Installation Instructions Transponder EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the

More information

Conettix D6680. Installation Instructions. Ethernet Network Adapter

Conettix D6680. Installation Instructions. Ethernet Network Adapter Conettix D6680 EN Installation Instructions Ethernet Network Adapter Conettix D6680 Installation Instructions Trademarks Trademarks Microsoft Windows 98SE, Windows ME, Windows 2000, Windows NT, MS-DOS,

More information

MultiModem rcell. Intelligent Wireless Router. Quick Start Guide

MultiModem rcell. Intelligent Wireless Router. Quick Start Guide MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2 82100400L, Revision A Copyright 2009 by Multi-Tech Systems,

More information

Installation of Firmware Updates on H-2221 GOES Transmitters

Installation of Firmware Updates on H-2221 GOES Transmitters Technical Note H-5221 Firmware Update D117 November 2, 2018 Installation of Firmware Updates on H-2221 GOES Transmitters INTRODUCTION The intent of this document is to provide WaterLOG H-2221 GOES transmitter

More information

GC 055. GSM Remote Monitoring. Operating and installation instructions

GC 055. GSM Remote Monitoring. Operating and installation instructions GSM Remote Monitoring Operating and installation instructions GC 055 GSM, GPRS Programmable Communicator Transmits input conditions/controls outputs Measures analogue data Access control system/dallas

More information

GSM communicator G09 (v.1.61) User Manual and Installation Guide. Draugystes g. 17, LT Kaunas

GSM communicator G09 (v.1.61) User Manual and Installation Guide. Draugystes g. 17, LT Kaunas GSM communicator G09 (v.1.61) User Manual and Installation Guide Draugystes g. 17, LT-51229 Kaunas E-mail: info@trikdis.lt www.trikdis.lt Purpose of the document This document introduces the features of

More information

Control Panels. D9412GV4/D7412GV4 v en Release Notes

Control Panels. D9412GV4/D7412GV4 v en Release Notes Control Panels D9412GV4/D7412GV4 v2.03.018 en Release Notes Control Panels Table of Contents en 3 Table of contents 1 Introduction 5 1.1 Requirements 5 1.2 About documentation 5 1.2.1 Related documentation

More information

A1000 GSM ALARM DEVICE

A1000 GSM ALARM DEVICE A1000 GSM ALARM DEVICE USER MANUAL A1000-REV2.1-1604 FW-A1000v2.93 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for installation,

More information

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT Honeywell 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HP600ULACM4CB HP600ULACM8CB Access Control Power Supply/Charger with Power Distribution Controller PN 52395:A 1/05/06 ECN

More information

Quick Start Guide LES1308A, LES1316A LES1332A, LES1348A. Securely manage data center and network equipment from anywhere in the world.

Quick Start Guide LES1308A, LES1316A LES1332A, LES1348A. Securely manage data center and network equipment from anywhere in the world. LES1308A, LES1316A LES1332A, LES1348A 8-/16-/32-/48-Port Advanced Console Server with GSM Modem QS Guide Quick Start Guide Securely manage data center and network equipment from anywhere in the world.

More information

GSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania

GSM module G10T (v.2.3x) Installation manual. TRIKDIS, JSC Draugystės st. 17, LT Kaunas Lithuania GSM module G10T (v.2.3x) Installation manual TRIKDIS, JSC Draugystės st. 17, LT-51229 Kaunas Lithuania E-mail: info@trikdis.lt www.trikdis.lt Table of Contents GSM module G10T... 3 Operating... 3 Outside

More information

FSA-CU Configuration Utility Programming Guide

FSA-CU Configuration Utility Programming Guide FSA-CU Configuration Utility Programming Guide Revision 3 October 2013 Introduction The following guide will show you the basics of the FSA-CU configuration utility program. The CU can be used with the

More information

PS/IO Circuit Board Retrofit

PS/IO Circuit Board Retrofit S&C 6800 Series Automatic Switch Controls PS/IO Circuit Board Retrofit Table of Contents Section Page Introduction Qualified Persons.... 2 Read this Instruction Sheet.... 2 Retain this Instruction Sheet....

More information

Installing and Managing the Switch

Installing and Managing the Switch CHAPTER 2 This chapter describes how to install and manage the Cisco SFS 7008 system hardware and contains these sections: Safety, page 2-2 Preparing the Site, page 2-3 Rack-Mounting the Switch, page 2-4

More information

Conettix ITS-D6682-INTL

Conettix ITS-D6682-INTL Conettix ITS-D6682-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6682-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...

More information

CoverTitle. Raven XT. Quick Start Guide for AT&T Rev 3.0E

CoverTitle. Raven XT. Quick Start Guide for AT&T Rev 3.0E Raven XT Quick Start Guide for AT&T CoverTitle 20070914 Rev 3.0E Activating your Raven XT on AT&T Installing the SIM Configuring the APN Hardware Installation Indicator Lights Optional: Setting up a DUN

More information

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 4XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Communication adapter RS485/422 over the Ethernet ELO E222. User manual

Communication adapter RS485/422 over the Ethernet ELO E222. User manual Communication adapter RS485/422 over the Ethernet ELO E222 User manual Table Of Content: 1.0 Introduction... 3 1.1 Application... 3 2.0 How does it works?... 4 3.0 Installation... 4 3.1 Ethernet connection...

More information

ELK-C1M1 Information Addendum

ELK-C1M1 Information Addendum ELK-C1M1 Information Addendum In addition to its super fast, dual path, alarm communications capability, the C1M1 also boasts support of Elk-RP remote programming of the M1 Control by the Alarm Company,

More information

Remote Programming Software (RPS) D5500CU v6.05

Remote Programming Software (RPS) D5500CU v6.05 Remote Programming Software (RPS) D5500CU v6.05 en Release Notes Remote Programming Software (RPS) Introduction en 3 1 Introduction RPS version 6.05 Release Notes Remote Programming Software (RPS) is

More information

Installing Sentor. Hardware Installation

Installing Sentor. Hardware Installation Remote base site monitoring and control Installing Sentor Hardware Installation Copyright 2000 Sentor Monitoring Systems Pty Ltd Contents: 1 Introduction... 1 2 Sentor GUI... 2 3 ST3000 Controller... 3

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Conettix ITS-D6686-INTL

Conettix ITS-D6686-INTL Conettix ITS-D6686-INTL EN Installation Guide Ethernet Network Adapter Conettix ITS-D6686-INTL Installation Guide Contents Contents 1.0 Introduction... 3 1.1 Network Interface... 3 1.2 Serial Interface...

More information

GlobeSurfer III. Quick Start Guide

GlobeSurfer III. Quick Start Guide GlobeSurfer III Quick Start Guide GlobeSurfer III User guide 2 Welcome to GlobeSurfer III Welcome to the GlobeSurfer III, your 3G wireless gateway router that connects you to the internet, allows you to

More information

PM Series Power Meter

PM Series Power Meter PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See

More information

GSM communicator G16 USER MANUAL

GSM communicator G16 USER MANUAL USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS... 2 DESCRIPTION... 3 LIST OF COMPATIBLE CONTROL PANELS...

More information

User Manual A08. User Manual

User Manual A08. User Manual A08 TABLE OF CONTENTS TABLE OF CONTENTS... 1 1. INTRODUCTION... 2 1.1. Key Features... 3 1.2. OS Requirement... 4 1.3. Specification... 4 1.4. Packing List... 4 2. OVERVIEW... 5 2.1. LED Definition...

More information

ModemUSB/E12 User Manual v0.1

ModemUSB/E12 User Manual v0.1 User Manual v0.1 TABLE OF CONTENTS TABLE OF CONTENTS...2 1. ATTENTION...3 2. FOR YOUR SAFETY...3 3. USER S SERVICE...5 4. BASIC INFORMATION...6 4.1 Introduction...6 4.2 Legal Notice...6 4.3 Contacts...6

More information

iologik 2500 Series Quick Installation Guide

iologik 2500 Series Quick Installation Guide iologik 2500 Series Quick Installation Guide Smart Remote I/O Edition 5.0, December 2016 Technical Support Contact Information www.moxa.com/support Moxa Americas: Toll-free: 1-888-669-2872 Tel: 1-714-528-6777

More information

Quick Start Installation Guide

Quick Start Installation Guide apc/l Quick Start Installation Guide Version A2 Document Part Number UM-201 May 2010 OVERVIEW The apc/l is an intelligent access control and alarm monitoring control panel which serves as a basic building

More information

Panoramic Power Installation and configuration guide

Panoramic Power Installation and configuration guide Panoramic Power Installation and configuration guide Advanced 4th generation Bridge for firmware v259 Version 1 1 Copyright notice Copyright 2017 Panoramic Power Ltd. All rights reserved. Panoramic Power

More information

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3

THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL. Digi-modems. Issue 3 THANK YOU FOR VOTING TEXECOM INSTALLATION MANUAL Digi-modems Issue 3 Contents Com300 & Com2400 Installation Manual Contents 1. Regulatory Requirements... 3 General...3 Approval... 3 REN Rating... 3 2.

More information

GSM HOME SECURITY SYSTEM

GSM HOME SECURITY SYSTEM Cell /Mobile phone home security system GSM HOME SECURITY SYSTEM Model : BS120 TABLE OF CONTENTS 1. FEATURES... 1 2. APPLICATION... 2 3. SPECIFICATIONS... 3 4. FRONT PANEL & LAYOUT DESCRIPTION...6 5. BASIC

More information

Content 1 OVERVIEW HARDWARE DESCRIPTION HARDWARE INSTALLATION PC CONFIGURATION GUIDE... 5 WEB-BASED MANAGEMENT GUIDE...

Content 1 OVERVIEW HARDWARE DESCRIPTION HARDWARE INSTALLATION PC CONFIGURATION GUIDE... 5 WEB-BASED MANAGEMENT GUIDE... Content 1 OVERVIEW...1 1.1FEATURES...1 1.2 PACKETCONTENTS...3 1.3 SYSTEM REQUIREMENTS... 1.4 FACTORY DEFAULTS...4 1.5 WARNINGS AND CAUTIONS...4 2 HARDWARE DESCRIPTION... 6 3 HARDWARE INSTALLATION...8 4

More information

Installation Instructions

Installation Instructions Alliance Arming Station AL-1111, AL-1116 1048520C September 2006 Copyright 2006, GE Security Inc. Introduction This is the GE Alliance Arming Station for models AL-1111 (four-line LCD) and AL-1116 (four-line

More information

CR3000 Copy Reader. Installation Guide

CR3000 Copy Reader. Installation Guide CR3000 Copy Reader Installation Guide CONTENTS CONTENTS 1 CR3000 Installation Guide 1 What you get: 2 Installation Overview 3 Install the Reader 4 Mount the Reader 4 Connect the Reader Cables 5 Connect

More information

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs MobilTherm 2ad GSM temperature alarm module with auxiliay inputs and relay outputs The MobilTherm-2ad is a GSM temperature and remote signaling module, designed for GSM based remote control, remote signal.

More information

CA-A480-A Elevator Controller. Reference & Installation Manual

CA-A480-A Elevator Controller. Reference & Installation Manual CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................

More information

Anybus Wireless Bridge II

Anybus Wireless Bridge II Anybus Wireless Bridge II STARTUP GUIDE SCM-1202-013/SP2167-EN 1.7 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide Trademark Notices Comtrol, NS-Link, and DeviceMaster are trademarks of Comtrol Corporation. Microsoft and Windows are registered trademarks of Microsoft Corporation.

More information

Conettix Universal Dual Path Communicator B465

Conettix Universal Dual Path Communicator B465 Conettix Universal Dual Path Communicator B465 en Release Notes Conettix Universal Dual Path Communicator Table of contents en 3 Table of contents 1 Introduction 4 1.1 Requirements 4 2 Version 2.00.000

More information

DUAL SWITCH CONTROLLER

DUAL SWITCH CONTROLLER DUAL SWITCH CONTROLLER INSTRUCTION MANUAL IMPORTANT: If the Dual Switch Controller is to be used with a Dielectric 50000 Series Switch, control cable P/N 1100007364 or 11000007365 must be used. See Section

More information

THE i-stat 1 DOWNLOADER/RECHARGER (MODEL NUMBER DRC-300)

THE i-stat 1 DOWNLOADER/RECHARGER (MODEL NUMBER DRC-300) i-stat TECHNICAL BULLETIN THE i-stat 1 DOWNLOADER/RECHARGER (MODEL NUMBER DRC-300) OVERVIEW This Technical Bulletin describes the instructions for using the new i-stat 1 Downloader/Recharger (DRC), which

More information

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA Webpage: GSM communicator G16T USER MANUAL

UAB TRIKDIS Draugystės str. 17, LT Kaunas LITHUANIA   Webpage:  GSM communicator G16T USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt GSM communicator G16T USER MANUAL Contents SAFETY REQUIREMENTS... 2 1 DESCRIPTION... 3 SPECIFICATIONS...

More information

Quick Start Guide. The Automotive Internet Experience

Quick Start Guide. The Automotive Internet Experience Quick Start Guide The Automotive Internet Experience Table of Contents System Requirements Package Contents Overview Wi2U router Vehicle Installation Start-up Display Settings Regulatory Information Technical

More information

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide

MRD-310 MRD G Cellular Modem / Router Web configuration reference guide. Web configuration reference guide Web configuration reference guide 6623-3201 MRD-310 MRD-330 Westermo Teleindustri AB 2008 3G Cellular Modem / Router Web configuration reference guide www.westermo.com Table of Contents 1 Basic Configuration...

More information

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1- KSD-800 Series Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity Installation Guide DOC.110516A -1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

3G Cell Modem Installation and User Guide

3G Cell Modem Installation and User Guide 3G Cell Modem Installation and User Guide For BaseStation 1000 & BaseStation 3200 Irrigation Controllers in X and XS Cabinets April 24, 2017 Customer Service 1-866-294-5847 Baseline Inc. www.baselinesystems.com

More information

TELTONIKA EDGE camera (MVC100) User s Manual 1.01

TELTONIKA EDGE camera (MVC100) User s Manual 1.01 TELTONIKA EDGE camera (MVC100) User s Manual 1.01 LEGAL NOICE Copyright 2008 TELTONIKA Ltd. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document

More information

Installing the EN-4000

Installing the EN-4000 EN-4000 Reference Manual Document 2 Installing the EN-4000 T his document discusses installation of the EN-4000 hardware. Note: The EN-4000 Quick Installation Guide is also available. 2.1 Collecting the

More information

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1 A1400 GSM Temperature Alarm USER MANUAL A1400-REV2.1-1604 FW-A1400v2.94 ERBAŞ TEKNOLOJİ Innovative Solutions 1 www.erbasteknoloji.com SAFETY INSTRUCTIONS - This user manual contains important notices for

More information

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

GSM-X. Communication module. Quick installation guide. Full manual is available on   Firmware version 1.02 gsm-x_sii_en 08/18 GSM-X Communication module Quick installation guide Full manual is available on www.satel.eu Firmware version 1.02 gsm-x_sii_en 08/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk Poland tel. +48 58

More information

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot Overview Fingerprint & Finger Vein Device Front Left Side: Finger Vein Device Touch screen Card reader Fingerprint reader Finger vein reader Finger vein sensor: During registration, after finger touches

More information

MultiModem rcell Intelligent Wireless Router. Quick Start Guide

MultiModem rcell Intelligent Wireless Router. Quick Start Guide MultiModem rcell Intelligent Wireless Router Quick Start Guide Copyright and Technical Support Quick Start Guide MultiModem rcell MTCBA-Xx-EN2, MTCBA-Xx-EN2-GP 82100511L, Revision A Copyright 2010 by Multi-Tech

More information

Quick Start Guide. Preparation. Installation. Operation. Support. Vaisala NOMAD 3 Data Logger. Online manuals

Quick Start Guide. Preparation. Installation. Operation. Support. Vaisala NOMAD 3 Data Logger. Online manuals Quick Start Guide www.vaisala.com Vaisala NOMAD 3 Data Logger Preparation Package Contents Plan Instrumentation Create a SkyServe Account Activating the Nomad 3 Nomad 3 Toolbox Create Setup Files 2 4 5

More information

ewon Flexy PSTN Extension Card FLA 3501

ewon Flexy PSTN Extension Card FLA 3501 Installation Guide IG 021 / Rev. 1.2 FLA 3501 This installation guide explains how to install the FLA 3501. support.ewon.biz Table of Contents 1. Product Summary... 3 2. Safety, Environmental & Regulatory

More information

ACTpro Single Door IP Controller. Operating & Installation Instructions

ACTpro Single Door IP Controller. Operating & Installation Instructions ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control

More information

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998 SuperBus Hardwire Input Module (HIM) Document Number: 466-1033 Rev. C September 1998 SuperBus Hardwire Input Module for installing a magnetic reed switch* that can provide tamper protection when the switch

More information

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL

RN-WIFLY-EVAL-UM. WiFly Evaluation Kit Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-1.0 Version /8/2011 USER MANUAL RN-WIFLY-EVAL-UM WiFly Evaluation Kit 0 Roving Networks. All rights reserved. RN-WIFLY-EVAL-UM-.0 Version.0 //0 USER MANUAL OVERVIEW This document describes the hardware and software setup for Roving Networks

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

Table of Contents. Page ii

Table of Contents. Page ii Table of Contents Chapter 1 Introduction 1 Features... 1 Safety Instructions... 1 Package Contents... 2 Physical Details... 3 Chapter 2 Setup 5 Overview... 5 Using the Windows Wizard... 5 Chapter 3 Web-Based

More information

HydroGuard Expert Pool Manual

HydroGuard Expert Pool Manual HydroGuard Expert Pool Manual Draft 09 May 2006 Swimming Pool Quality Communication and Monitoring Preface Intended Use This manual is for qualified and trained pool service technicians who will install

More information

INT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18

INT-GSM. GPRS communication module. Firmware version 1.00 int-gsm_en 07/18 INT-GSM GPRS communication module Firmware version 1.00 int-gsm_en 07/18 SATEL sp. z o.o. ul. Budowlanych 66 80-298 Gdańsk POLAND tel. +48 58 320 94 00 www.satel.eu IMPORTANT The module should be installed

More information

Netbiter EC300 Series

Netbiter EC300 Series Netbiter EC300 Series USER MANUAL SCM-1202-012 2.2 ENGLISH Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of

More information

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Peripheral Relay The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits. Up to 16 Cards can be connected to a multi-loop panel

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo

PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Instruction Manual Actual product may vary from photo PCI Serial Card 2 Port RS-422/RS-485 PCI Serial Card with Terminal Block Connectors PCI2S422TB Actual product may vary from photo FCC Compliance Statement This equipment has been tested and found to comply

More information

Service Managed Gateway TM. Installing and Configuring the GW8600 SMG

Service Managed Gateway TM. Installing and Configuring the GW8600 SMG Service Managed Gateway TM Installing and Configuring the GW8600 SMG Issue 1.1 Date 14 August 2007 Table of Contents 1 About this document...3 1.1 Scope...3 1.2 Readership...3 1.3 More information...3

More information

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL

NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL NCOM SERIAL DEVICE SERVER 1XX SERIES USER S MANUAL 2017-07-07 Edition Titan Electronics Inc. Web: www.titan.tw Contents 1. INTRODUCTION... 4 1.1 Key Features... 5 1.2 Specifications... 6 2. PANEL LAYOUT

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

GSM communicator G16 USER MANUAL

GSM communicator G16 USER MANUAL USER MANUAL UAB TRIKDIS Draugystės str. 17, LT-51229 Kaunas LITHUANIA E-mail: info@trikdis.lt Webpage: www.trikdis.lt Contents SAFETY REQUIREMENTS...2 DESCRIPTION...3 LIST OF COMPATIBLE CONTROL PANELS...3

More information

Digital Keypad Introduction

Digital Keypad  Introduction K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming

More information

Beacon Power Supply Operating and Installation Instruction Manual

Beacon Power Supply Operating and Installation Instruction Manual Beacon Power Supply Operating and Installation Instruction Manual Model: BNx000 Page 1 of 27 I. Warnings and Notices I. WARNING - To reduce the risk of fire or electric shock, do not expose this product

More information

Remote Programming Software (RPS) D5500CU v6.04

Remote Programming Software (RPS) D5500CU v6.04 Remote Programming Software (RPS) D5500CU v6.04 en Release Notes Remote Programming Software (RPS) Introduction en 3 1 Introduction RPS version 6.04 Release Notes Remote Programming Software (RPS) is

More information

D1260/D1260B. Installation Guide. Keypads

D1260/D1260B. Installation Guide. Keypads D1260/D1260B EN Installation Guide Keypads D1260/D1260B Installation Guide Trademarks Trademarks Microsoft, Windows, Windows NT are either registered trademarks or trademarks of Microsoft Corporation in

More information

CoverTitle. PinPoint XT. Quick Start Guide for AT&T Rev 1.0

CoverTitle. PinPoint XT. Quick Start Guide for AT&T Rev 1.0 PinPoint XT Quick Start Guide for AT&T CoverTitle 20070914 Rev 1.0 Activating your PinPoint XT on AT&T Installing the SIM Configuring the APN Hardware Installation Indicator Lights Optional: Setting up

More information

Communication adapter RS232 over the Wi-Fi ELO E231. User manual

Communication adapter RS232 over the Wi-Fi ELO E231. User manual Communication adapter RS232 over the Wi-Fi ELO E231 User manual Table Of Content: 1.0 Introduction...3 1.1 Application...3 2.0 How does it works?...4 3.0 Installation...4 3.1 Wi-Fi connection...4 3.2 RS-232

More information

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10

PumpDrive DPM. Installation and Operating Instructions Dual Pump Module (DPM) /4--10 4070.83/4--10 PumpDrive DPM Installation and Operating Instructions Dual Pump Module (DPM) These installation and operating instructions are not valid on their own. They must always be applied in conjunction

More information

RM6000 GPRS Modem / Router

RM6000 GPRS Modem / Router User Manual Version 6.30 AMG Systems Ltd March 2013 3 The Omega Centre Stratton Business Park Biggleswade Bedfordshire, UK SG18 8QB Tel: 44 (0) 1767 600777 sales@amgsystems.com 1. Introduction 2. RM6000

More information