StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5

Size: px
Start display at page:

Download "StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5"

Transcription

1 One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5 AUGUST 2018 TECHNICAL PAPER

2 Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind Software. StarWind LSFS is a trademark of StarWind Software which may be registered in some jurisdictions. All other trademarks are owned by their respective owners. Changes The material in this document is for information only and is subject to change without notice. While reasonable efforts have been made in the preparation of this document to assure its accuracy, StarWind Software assumes no liability resulting from errors or omissions in this document, or from the use of the information contained herein. StarWind Software reserves the right to make changes in the product design without reservation and without notification to its users. Technical Support and Services If you have questions about installing or using this software, check this and other documents first - you will find answers to most of your questions on the Technical Papers webpage or in StarWind Forum. If you need further assistance, please contact us. About StarWind StarWind is a pioneer in virtualization and a company that participated in the development of this technology from its earliest days. Now the company is among the leading vendors of software and hardware hyperconverged solutions. The company s core product is the years-proven StarWind Virtual SAN, which allows SMB and ROBO to benefit from cost-efficient HyperСonverged IT infrastructure. Having earned a reputation of reliability, StarWind created a hardware product line and is actively tapping into HyperСonverged and storage appliances market. In 2016, Gartner named StarWind Cool Vendor for Compute Platforms following the success and popularity of StarWind HyperСonverged Appliance. StarWind partners with world-known companies: Microsoft, VMware, Veeam, Intel, Dell, Mellanox, Citrix, Western Digital, etc. Copyright StarWind Software Inc. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording or otherwise, without the prior written consent of StarWind Software. TECHNICAL PAPER 2

3 Contents Introduction...4 Solution Diagram...5 Preparing Hypervisor for StarWind Deployment...6 Creating Datacenter Preparing StarWind Virtual Machines Downloading, Installing and Registering the Software Provisioning Storage with StarWind VSAN Preparing Datastores Conclusion Contacts TECHNICAL PAPER 3

4 Introduction VMware requires a shared storage to guarantee the data safety and allow the virtual machines migration. It enables continuous application availability and eliminates any single point of failure within IT environment. VMware users have two options when choosing the shared storage: Hyperconverged solutions allow sharing the same hardware resources for the application (i.e. hypervisor, database) and the shared storage, thus decreasing the TCO and achieving the outstanding performance results. Compute and Storage Separated solutions keep compute and storage layers separately from each other, thus making the maintenance easier, increasing the hardware usage efficiency and allowing users to build the system accurately for solving the tasks. This guide is intended for the experienced VMware and Windows system administrators and IT professionals who would like to configure StarWind Virtual SAN Hyperсonverged solution for vsphere deployments. It provides a step-by-step guidance on configuring a 3-node vsphere cluster using StarWind Virtual SAN to convert the local storage of the ESXi hosts into a fault-tolerant shared storage resource for ESXi. The document describes the configuration using Heartbeat failover strategy. A full set of up-to-date technical documentation can always be found here, or by pressing the Help button in StarWind Management Console. For any technical inquiries please visit our online community, Frequently Asked Questions page, or use the support form to contact our technical support department. TECHNICAL PAPER 4

5 Solution Diagram The diagram bellow illustrates the network and storage configuration of the resulting solution described in the guide. TECHNICAL PAPER 5

6 Preparing Hypervisor for StarWind Deployment Configuring Networks Configure network interfaces on each node to make sure that Synchronization and iscsi/starwind Heartbeat interfaces are in different subnets and connected physically according to the network diagram above. In this document, x, x, x subnets are used for iscsi/starwind Heartbeat traffic, while x, x, x subnets are used for the Synchronization traffic. All the actions below should be applied to each ESXi server. 1. Go to Networking -> Virtual Switches and click Add standard virtual switch. Type vswitch Name, set MTU to 9000 and specify proper uplink. Create four vswitches: two for the iscsi/ StarWind Heartbeat channel and two for the Synchronization channel. TECHNICAL PAPER 6

7 TECHNICAL PAPER 7

8 2. Create two VMkernel ports one per each iscsi/ StarWind Heartbeat channel at Networking -> VMkernel NICS. Create new Port groups while adding VMkernel ones. Specify the static IPv4 address for each VMkernel. TECHNICAL PAPER 8

9 3. Add four more Virtual Machine Port Groups: two more for iscsi/starwind Heartbeat channel and two for Synchronization channel. Assign vswitch used for specified traffic at Networking -> Port groups tab. TECHNICAL PAPER 9

10 4. Repeat the steps 1-3 for any other links intended for Synchronization and iscsi/heartbeat traffic on all ESXi nodes. Assign the corresponding subnets to VMkernels on the second and third hosts. TECHNICAL PAPER 10

11 Creating Datacenter NOTE: Before creating Datacenter, the vcenter server should be deployed. 5. Connect to vcenter, select the Getting Started tab, click on Create Datacenter and enter Datacenter name. TECHNICAL PAPER 11

12 TECHNICAL PAPER 12

13 Creating Cluster 6. Click the Datacenter Getting Started tab and Create a cluster. Enter the name of the cluster and click Next. TECHNICAL PAPER 13

14 Adding Hosts to Cluster 7. Open the Cluster tab and click Add a host. 8. Enter the name or IP address of the ESXi host and enter the administrative account. TECHNICAL PAPER 14

15 9. Lockdown mode is disabled by default. TECHNICAL PAPER 15

16 10. Apply the license by clicking Home -> Administration -> Licensing. Verify the settings. TECHNICAL PAPER 16

17 Preparing StarWind Virtual Machines 11. Create Virtual Machines (VMs) on each ESXi host with Windows Server 2016 (2012 R2) and StarWind VSAN installed. Make sure that server hardware used for StarWind Virtual SAN deployment satisfies the requirements listed below. Minimum requirements: RAM: 4 GB (plus the size of the RAM cache if it is planned to be used); CPUs: 4 virtual processors with 2 GHz reserved; Hard disk 1: 100 GB for OS (recommended) The location of StarWind VM on the local drive (Boss card, SATA DOM, etc.) makes it possible to connect the underlying storage to StarWind VM as RDM disk; Hard disk 2: depends on the storage volume to be used as shared storage. Each hard disk should be Thick Provisioned Eager Zeroed. NOTE: Each hard disk should be Thick Provisioned Eager Zeroed. Network adapter 1: Management Network adapter 2: iscsi for connection from first to second node Network adapter 3: iscsi for connection from first to third node Network adapter 4: Sync for connection from first to second node Network adapter 5: Sync for connection from first to third node NOTE: All the network adapters should be configured as VMXNET 3. It is recommended to set jumbo frames to 9000 on vswitches and VMkernel ports for iscsi and Synchronization traffic. Additionally, vmotion can be enabled on VMkernel ports. NOTE: In this technical guide, a Windows Server 2016-based virtual machine created to run StarWind Virtual SAN is called StarWind Virtual Machine (StarWind VM). Active Directory Domain Services role can be added on StarWind VM if necessary. Thus, it can serve as a domain controller. NOTE: It is not recommended to make backups and snapshots of StarWind VM with synchronous replication feature inside as this can pause the VM operation. Pausing the VMs while StarWind service is under load may lead to split-brain issues and data corruption. TECHNICAL PAPER 17

18 Configuring StarWind VMs autostart/shutdown 12. Login to vcenter Web Client and configure the StarWind VMs autostart policy on each ESXi hosts in the Configure -> VM Startup/Shutdown tab. TECHNICAL PAPER 18

19 13. Click Edit to configure the VM Startup/Shutdown policies. Check Automatically start and stop the virtual machines with the system option. Select Guest shutdown action as the shutdown action. Move StarWind VMs and vcenter VM up to setup Automatic Startup. Click OK to proceed. 14. Complete the actions on each ESXi host. TECHNICAL PAPER 19

20 15. Turn on vsphere HA, click Cluster -> Configure -> Edit. 16. Start the StarWind VMs, install OS and StarWind Virtual SAN. TECHNICAL PAPER 20

21 Downloading, Installing and Registering the Software 17. Download the StarWind setup executable file from StarWind website by following the link: Launch the downloaded setup file on the server where StarWind Virtual SAN or one of its components should be installed. The setup wizard will appear. 19. Read and accept the License Agreement. Click Next to continue. TECHNICAL PAPER 21

22 20. Carefully read the information about new features and improvements. Red text indicates warnings for users who are updating existing software installations. Click Next to continue. 21. Specify one of the following installation types and the components which should be installed: Full installation (recommended): Full installation includes both StarWind Service and the StarWind Management Console elements. It allows users to manage storage resources on the machine where StarWind Virtual SAN is installed, as well as manage other StarWind Virtual SAN installations on the network. StarWind Virtual SAN Service: This installation type is designed for Core OS editions. StarWind Service is the core of the software. It enables the creation of iscsi targets as well as sharing virtual and physical devices. StarWind Management Console installed on any Windows computer or virtual machine in the network can manage the service. TECHNICAL PAPER 22

23 StarWind Management Console: StarWind Management Console is the Graphic User Interface (GUI) part of the software that controls and monitors all storage-related operations (e.g. allows users to create targets and devices on the available Virtual SAN servers). Once installed, StarWind Management Console is connected to the servers running StarWind Virtual SAN. TECHNICAL PAPER 23

24 22. Specify Start Menu Folder and click Next to continue. 23. Enable the checkbox to create a desktop icon. Click Next. TECHNICAL PAPER 24

25 24. The appeared prompt will ask to request a time-limited fully functional evaluation key, a FREE version key, or a fully-commercial license key sent to you with the purchase of StarWind Virtual SAN. Select the appropriate option. 25. Click Browse to locate the license file and click Next. TECHNICAL PAPER 25

26 26. Review the licensing information. Click Next to apply the license key. 27. Verify the installation settings. Click Back to make any changes or Install to continue. TECHNICAL PAPER 26

27 28. Click Finish to complete the installation process. Optionally, StarWind Management Console can be launched by ticking the corresponding checkbox. 29. Repeat the steps above on all StarWind Virtual Machines. TECHNICAL PAPER 27

28 Configuring Automatic Storage Rescan For each ESXi host, configure an automatic storage rescan. 30. Log in to StarWind VM and install vsphere PowerCLI on each StarWind Virtual Machine by adding the PowerShell module (Internet connectivity is required). To do so, run the following command in PowerShell: Install-Module -Name VMware.PowerCLI -AllowClobber NOTE: In case of using Windows Server 2012 R2, online installation of PowerCLI requires Windows Management Framework 5.1 or later version available on VMs. Windows Management Framework 5.1 can be downloaded by following the link: Open PowerShell and change the Execution Policy to Unrestricted by running the following command: Set-ExecutionPolicy Unrestricted TECHNICAL PAPER 28

29 32. Create the PowerShell script which will perform an HBA rescan on the hypervisor host. Import-Module VMware.PowerCLI $counter = 0 if ($counter -eq 0){ Set-PowerCLIConfiguration -InvalidCertificateAction ignore -Confirm:$false Out-Null } $ESXiHost = "IP address" $ESXiUser = "Login" $ESXiPassword = "Password" Connect-VIServer $ESXiHost -User $ESXiUser -Password $ESXiPassword Out-Null Get-VMHostStorage $ESXiHost -RescanAllHba Out-Null Get-ScsiLun -VMHost $ESXiHost -LunType disk Where-Object Vendor -EQ "STARWIND" Where-Object ConsoleDeviceName -NE " " Set-ScsiLun -MultipathPolicy RoundRobin Out-Null $StarwindCN = Get-ScsiLun -VMHost $ESXiHost -LunType disk Where-Object Vendor -EQ "STARWIND" Where-Object ConsoleDeviceName -NE " " Select-Object CanonicalName $esxcli = Get-EsxCli -VMHost $ESXiHost foreach($cn in $StarwindCN){ $esxcli.storage.nmp.psp.roundrobin.deviceconfig.set(0,$null,$cn.canonicalname,1,` "iops",0) Out-Null } Disconnect-VIServer $ESXiHost -Confirm:$false $file = Get-Content "$PSScriptRoot\rescan_script.ps1" if ($file[1] -ne "`$counter = 1") { $file[1] = "`$counter = 1" $file > "$PSScriptRoot\rescan_script.ps1" } In the appropriate lines, specify the IP address and login credentials of the ESXi host on which the current StarWind VM is stored and running: $ESXiHost1 = IP address $ESXiUser = Login $ESXiPassword = Password Save the script as rescan_script.ps1 to the root of the C:\ drive of the VM. TECHNICAL PAPER 29

30 33. Perform the configuration steps above on the partner nodes. 34. Go to Control Panel -> Administrative Tools -> Task Scheduler -> Create Basic Task and follow the wizard steps: TECHNICAL PAPER 30

31 35. Specify the task name, select When a specific event is logged option, and click Next. 36. Select Application in the Log dropdown menu, type StarWindService as the event source and 788 as event ID. Click Next. TECHNICAL PAPER 31

32 37. Select the Start a Program option as the action the task should perform and click Next. 38. Type powershell.exe in the Program/script field. In the Add arguments field, type: -ExecutionPolicy Bypass -NoLogo -NonInteractive -NoProfile -WindowStyle Hidden -File C:\rescan_script.ps1 TECHNICAL PAPER 32

33 39. Click Finish to exit the Wizard. 40. Configure the task to run with the highest privileges by enabling the corresponding checkbox at the bottom of the window. Make sure that Run whether user is logged on or not option is selected. TECHNICAL PAPER 33

34 41. Switch to the Triggers tab. Verify that the trigger on event 788 is set up correctly. 42. Click New and add other triggers for Event ID 782, 257, 773, and 817. TECHNICAL PAPER 34

35 43. All the added triggers should look like in the picture below. 44. Switch to the Actions tab and verify the task parameters. Press OK and type in the credentials for the user whose rights will be used to execute the command. 45. Perform the same steps on all StarWind VMs, specifying the corresponding settings. TECHNICAL PAPER 35

36 Provisioning Storage with StarWind VSAN Creating StarWind HA devices (DS1, DS2) 46. Open StarWind Management Console and click on the Add Device (advanced) button. TECHNICAL PAPER 36

37 47. Select Hard disk device as the type of device to be created. Click Next to continue. 48. Select the Virtual disk option as a disk device type and click Next to continue. TECHNICAL PAPER 37

38 49. Specify virtual disk Name, Location, and Size. Click Next to continue. 50. Specify Virtual Disk Options. NOTE: Sector size should be 512 bytes when using ESXi. TECHNICAL PAPER 38

39 51. Define the RAM caching policy and specify the cache size in corresponding units. NOTE: It is recommended to assign 1 GB of L1 cache in Write-Back or Write-Through mode per 1 TB of storage capacity. The cache size should correspond to the storage working set of the servers. 52. Define the Flash caching policy and the cache size. Click Next to continue. NOTE: The recommended size of the L2 cache is 10% of the initial StarWind device capacity. TECHNICAL PAPER 39

40 53. Specify Target Parameters. Select the Target Name checkbox to enter a custom name of the target if required. Otherwise, the name will be generated automatically in accordance with the specified target alias. Click Next to continue. 54. Click Create to add a new device and attach it to the target and Finish to close the wizard. 55. Right-click on the recently created device and select Replication Manager from the shortcut menu. TECHNICAL PAPER 40

41 56. Click Add replica. 57. Select Synchronous Two-Way Replication as a replication mode. Click Next to proceed. TECHNICAL PAPER 41

42 58. Specify partner host name, IP address and port number. Click Next to proceed. TECHNICAL PAPER 42

43 59. Select the Failover Strategy policy. NOTE: With Heartbeat failover strategy, one node remains active even in case of all partner nodes failure. With Node Majority failover strategy, the system can tolerate failure of only one node. If two nodes fail, the third one will become unavailable to the clients requests. This document describes the creation of an HA device with Heartbeat failover strategy. The creation of an HA device with Node Majority failover strategy is covered in the following document: TECHNICAL PAPER 43

44 60. Select Create new Partner Device and click Next. 61. Select the device location and specify target name if required. Otherwise, the name is generated automatically in accordance with the specified target alias. Click Next. TECHNICAL PAPER 44

45 62. Click Change Network Settings. 63. Specify interfaces for Synchronization and Heartbeat channels. Click OK->Next. TECHNICAL PAPER 45

46 64. Select Synchronize from existing Device. Click Next to continue Click Create Replica. 66. Click Finish to close the wizard. TECHNICAL PAPER 46

47 67. Add one more replica to the third StarWind VM. 68. Specify a partner hostname, IP address and port number. Click Next to proceed. TECHNICAL PAPER 47

48 69. Create a new partner device or select an existing device. Click Next. 70. Click Change network settings. TECHNICAL PAPER 48

49 71. Click Create Replica. 72. Click Finish to close the wizard. TECHNICAL PAPER 49

50 73. The successfully added devices will appear in the StarWind Management Console. Repeat the steps above to create other virtual disks that will be used as datastores. TECHNICAL PAPER 50

51 Preparing Datastores Adding Discover Portals 74. To connect the previously created devices to the ESXi host, click Storage Adapters and +, select Software iscsi adapter and the Enabled option to enable Software iscsi storage adapter. 75. On the same page, go below and click Targets tab. Click Add to add dynamic targets. TECHNICAL PAPER 51

52 76. In iscsi Server field, enter the iscsi IP address of the first StarWind node and add other IP addresses of the second and third StarWind nodes from the virtual local networks *. Click Save configuration. 77. Rescan all storage adapters. The result should look like in the image below. Now, the previously created StarWind devices are visible. 78. Repeat all the steps from this section on all three ESXi nodes, specifying corresponding IP addresses for the iscsi subnet. TECHNICAL PAPER 52

53 Creating datastores 79. Right-click on Datacenter ->Storage ->New Datastore. 80. Select VMFS Datastore and click Next. On the next step, type the Datastore name, select the previously discovered StarWind device, and click Next. TECHNICAL PAPER 53

54 81. Select the VMFS 6 file system. Click Next. 82. Enter Datastore size. Click Next. TECHNICAL PAPER 54

55 83. Verify the settings. Click Finish. 84. Add another Datastore (DS2) in the same way but select the second device for the second datastore. 85. Verify that the storages (DS1, DS2) are connected to all hosts. Otherwise, rescan the storage adapter. TECHNICAL PAPER 55

56 86. Path Selection Policy changing for Datastores from Most Recently Used (VMware) to Round Robin (VMware) has been already added into the Rescan Script, and this action is performed automatically. For checking and changing this parameter manually, the hosts should be connected to vcenter. 87. Multipathing configuration can be checked only in vcenter. To check it, click the Configure button, select the Storage Devices tab, select the device, and click the Edit Multipathing button. 88. Select Round Robin (VMware) MPIO policy. TECHNICAL PAPER 56

57 Additional Tweaks 89. On each ESXi host open Configure tab, switch to Security Profile and then click Edit to configure Services. 90. Select SSH. Click start service and set up Startup Policy on Start, then select Start and Stop with host. TECHNICAL PAPER 57

58 91. Connect to the host using SSH client (e.g. Putty). 92. Check the storage device list and get UID of StarWind device(s) using the following command: esxcli storage nmp device list grep STARWIND 93. For devices, adjust Round Robin size from 1000 to 1 using the following command: esxcli storage nmp psp roundrobin deviceconfig set --type=iops --iops=1 -- device=starwind_uid NOTE. Paste UID of StarWind device in the end of the command. Also, this parameter has been already added into the Rescan Script and this action is performed automatically. 94. Repeat the steps above on each host for each datastore. TECHNICAL PAPER 58

59 Conclusion This technical paper covers the configuration of the StarWind Virtual SAN for Hyperconverged 3- node scenario with VMware 6.5. In this setup, all virtual machines are stored on the shared storage that is provided by StarWind. VMware HA provides VMs with redundancy, while StarWind is responsible for the storage uptime. The combination of StarWind shared storage and VMware ensures high availability for applications and data across the entire virtualized environment. Using StarWind VSAN, the local storage of both ESXi hosts is converted into a fault-tolerant shared storage synchronously ''mirrored'' between the nodes. Virtual SAN nested inside a VM and running on both ESXi hosts ensures data safety and maintains continuous application availability. TECHNICAL PAPER 59

60 Contacts US Headquarters EMEA and APAC (UK) (Spain and Portugal) Customer Support Portal: Support Forum: Sales: General Information: StarWind Software, Inc. 35 Village Rd., Suite 100, Middleton, MA USA , StarWind Software Inc. All rights reserved. TECHNICAL PAPER 60

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER One Stop Virtualization Shop Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are

More information

#1 HyperConverged Appliance for SMB and ROBO. StarWind Virtual SAN. Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER

#1 HyperConverged Appliance for SMB and ROBO. StarWind Virtual SAN. Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

StarWind Virtual SAN 2-Node Stretched Cluster on VMware vsphere 6.5

StarWind Virtual SAN 2-Node Stretched Cluster on VMware vsphere 6.5 One Stop Virtualization Shop 2-Node Stretched Cluster on VMware vsphere 6.5 JULY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered

More information

StarWind Virtual SAN Compute and Storage Separated 3 Nodes with VMware vsphere

StarWind Virtual SAN Compute and Storage Separated 3 Nodes with VMware vsphere #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Compute and Storage Separated with Windows Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2

StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2 One Stop Virtualization Shop StarWind Virtual SAN Compute and Storage Separated with Windows Server 2012 R2 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the

More information

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and

More information

StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016

StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA SMB File Server in Windows Server 2016 APRIL 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

Quick Start Guide: Creating HA Device with StarWind Virtual SAN

Quick Start Guide: Creating HA Device with StarWind Virtual SAN One Stop Virtualization Shop Quick Start Guide: August 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018

StarWind Virtual SAN. HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2. One Stop Virtualization Shop MARCH 2018 One Stop Virtualization Shop StarWind Virtual SAN HyperConverged 2-Node Scenario with Hyper-V Cluster on Windows Server 2012R2 MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the

More information

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2

StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 One Stop Virtualization Shop StarWind Virtual SAN Configuring HA Shared Storage for Scale-Out File Servers in Windows Server 2012R2 DECEMBER 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop Installing and Configuring SQL Server 2017 Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016

StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Hyperconverged 2-Node Scenario with Hyper-V Server 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN AWS EC2 Deployment Guide

StarWind Virtual SAN AWS EC2 Deployment Guide One Stop Virtualization Shop StarWind Virtual SAN AUGUST 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Virtual SAN for vsphere Software RAID Configuration Guide

StarWind Virtual SAN for vsphere Software RAID Configuration Guide One Stop Virtualization Shop StarWind Virtual SAN for vsphere Software RAID Configuration Guide NOVEMBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop

StarWind Virtual SAN. Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2. One Stop Virtualization Shop One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2014 Failover Cluster Instance on Windows Server 2012 R2 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual Storage Appliance v2.0 Installation Guide with VMware vsphere

StarWind Virtual Storage Appliance v2.0 Installation Guide with VMware vsphere One Stop Virtualization Shop StarWind Virtual Storage Appliance v2.0 Installation Guide with VMware vsphere MAY 2018 TECHNICAL PAPER V2.0 Trademarks StarWind, StarWind Software and the StarWind and the

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016

StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2019 (TP) Failover Cluster Instance on Windows Server 2016 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual SAN Creating HA device using Node Majority Failover Strategy

StarWind Virtual SAN Creating HA device using Node Majority Failover Strategy One Stop Virtualization Shop StarWind Virtual SAN Creating HA device using Node Majority Failover Strategy MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster

StarWind Virtual SAN Installation and Configuration of HyperConverged 2 Nodes with Hyper-V Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN of HyperConverged 2 Nodes with Hyper-V Cluster AUGUST 2016 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and

More information

StarWind Virtual SAN HA Devices Configuration Changes

StarWind Virtual SAN HA Devices Configuration Changes One Stop Virtualization Shop StarWind Virtual SAN HA Devices Configuration Changes MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are

More information

StarWind Virtual SAN Creating Stand-Alone Image File device

StarWind Virtual SAN Creating Stand-Alone Image File device One Stop Virtualization Shop StarWind Virtual SAN Creating Stand-Alone Image File device JULY 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos

More information

StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V

StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated 3-Node Setup with Hyper-V MAY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind

More information

StarWind Storage Gateway for Backblaze Getting Started

StarWind Storage Gateway for Backblaze Getting Started One Stop Virtualization Shop StarWind Storage Gateway for Backblaze JUNE 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind Virtual SAN 2-Node Stretched Hyper-V Cluster on Windows Server 2016

StarWind Virtual SAN 2-Node Stretched Hyper-V Cluster on Windows Server 2016 One Stop Virtualization Shop StarWind Virtual SAN 2-Node Stretched Hyper-V Cluster on Windows Server 2016 APRIL 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN VAAI (vstorage API for Array Integration) Configuration and Performance Tuning Guide

StarWind Virtual SAN VAAI (vstorage API for Array Integration) Configuration and Performance Tuning Guide One Stop Virtualization Shop StarWind Virtual SAN VAAI (vstorage API for Array Integration) Configuration and Performance Tuning Guide FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software

More information

StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V.

StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V. #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Compute and Storage Separated 2-Node Cluster. Creating Scale- Out File Server with Hyper-V. MARCH 2015 TECHNICAL PAPER Trademarks StarWind,

More information

StarWind Appliances Quick Start Guide

StarWind Appliances Quick Start Guide One Stop Virtualization Shop StarWind Appliances Quick Start Guide MAY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind Virtual Storage Appliance Installation Guide with KVM

StarWind Virtual Storage Appliance Installation Guide with KVM One Stop Virtualization Shop StarWind Virtual Storage Appliance APRIL 2017 TECHNICAL PAPER V 1.0 Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

Quick Start Guide: Creating VTL device with StarWind Virtual SAN

Quick Start Guide: Creating VTL device with StarWind Virtual SAN #1 HyperConverged Appliance for SMB and ROBO Quick Start Guide: Creating VTL device with StarWind Virtual SAN JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the

More information

StarWind Virtual SAN Working with StarWind LSFS Snapshots in ESXi

StarWind Virtual SAN Working with StarWind LSFS Snapshots in ESXi One Stop Virtualization Shop StarWind Virtual SAN Working with StarWind LSFS Snapshots in ESXi MARCH 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind VTL Storage Gateway for Azure and Veeam Installation and Configuration Guide

StarWind VTL Storage Gateway for Azure and Veeam Installation and Configuration Guide One Stop Virtualization Shop StarWind VTL OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, Starind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind Software.

More information

One Stop Virtualization Shop. StarWind RAM Disk FEBRUARY 2018 TECHNICAL PAPER

One Stop Virtualization Shop. StarWind RAM Disk FEBRUARY 2018 TECHNICAL PAPER One Stop Virtualization Shop StarWind RAM Disk FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012

StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012 One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server 2012 Failover Cluster Instance on Windows Server 2012 OCTOBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual SAN Automating Management with SMI-S in System Center Virtual Machine Manager 2016

StarWind Virtual SAN Automating Management with SMI-S in System Center Virtual Machine Manager 2016 One Stop Virtualization Shop StarWind Virtual SAN Automating Management with SMI-S in System Center Virtual Machine Manager 2016 FEBRUARY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and

More information

StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication

StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication One Stop Virtualization Shop StarWind Virtual SAN Virtual Tape Library used with Veeam Backup & Replication JUNE 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual Tape Library Used with Veritas Backup Exec

StarWind Virtual Tape Library Used with Veritas Backup Exec One Stop Virtualization Shop StarWind Virtual Tape Library SEPTEMBER 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind Virtual SAN Virtual Tape Library on Amazon Web Services with Microsoft System Center Data Protection Manager 2016

StarWind Virtual SAN Virtual Tape Library on Amazon Web Services with Microsoft System Center Data Protection Manager 2016 One Stop Virtualization Shop StarWind Virtual SAN Virtual Tape Library on Amazon Web Services with Microsoft System Center Data Protection Manager 2016 MAY 2017 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

StarWind Virtual SAN ODX (Off-loaded Data Transfer) Configuration and Performance Tuning Guide

StarWind Virtual SAN ODX (Off-loaded Data Transfer) Configuration and Performance Tuning Guide #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Configuration and Performance Tuning Guide APRIL 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind

More information

StarWind Virtual SAN Getting Started

StarWind Virtual SAN Getting Started #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN JUNE 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks

More information

StarWind Native SAN Configuring HA File Server for SMB NAS

StarWind Native SAN Configuring HA File Server for SMB NAS Hardware-less VM Storage StarWind Native SAN Configuring HA File Server for SMB NAS DATE: FEBRUARY 2012 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing & Configuring a SQL JANUARY 2015 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software

More information

StarWind iscsi SAN & NAS:

StarWind iscsi SAN & NAS: This document refers to the previous StarWind Virtual SAN version. To view the document for the current version, please follow this link StarWind iscsi SAN & NAS: Configuring HA Shared Storage for vsphere

More information

StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012

StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012 StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012 TRADEMARKS StarWind, StarWind Software and the StarWind and the StarWind Software logos are trademarks of StarWind

More information

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide 1 Table of Contents Introduction... 3 Prerequisites... 3 Hardware Configurations... 4 Storage... 4 VMWare ESXi Server... 4

More information

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright

More information

StarWind Virtual SAN Hybrid Cloud for Azure

StarWind Virtual SAN Hybrid Cloud for Azure One Stop Virtualization Shop StarWind Virtual SAN OCTOBER 2017 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

StarWind Virtual SAN. Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2

StarWind Virtual SAN. Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2 #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2 FEBRUARY 2016 TECHNICAL PAPER Trademarks StarWind,

More information

StarWind Virtual SAN Gentle Shutdown with PowerChute

StarWind Virtual SAN Gentle Shutdown with PowerChute Gentle Shutdown with PowerChute JULY 2018 TECHNICAL PAPER Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind Software. StarWind

More information

StarWind Virtual SAN Supports HA Storage for a vsphere VI with Virtualized iscsi Devices on DAS

StarWind Virtual SAN Supports HA Storage for a vsphere VI with Virtualized iscsi Devices on DAS #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Supports HA Storage for a vsphere VI with Virtualized iscsi Devices on DAS Cost Effective HA Storage for Critical Business Applications

More information

StarWind Native SAN for Hyper-V:

StarWind Native SAN for Hyper-V: This document refers to the previous StarWind Virtual SAN version. To view the document for the current version, please follow this link StarWind Native SAN for Hyper-V: Configuring HA Storage for Live

More information

StarWind iscsi SAN & NAS:

StarWind iscsi SAN & NAS: This document refers to the previous StarWind Virtual SAN version. To view the document for the current version, please follow this link StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October

More information

StarWind iscsi SAN Software: ESX Storage Migration

StarWind iscsi SAN Software: ESX Storage Migration StarWind iscsi SAN Software: ESX Storage Migration www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved. No part of this publication may

More information

StarWind Virtual SAN SQL Server HADR using Availability Groups and Failover Cluster Instance

StarWind Virtual SAN SQL Server HADR using Availability Groups and Failover Cluster Instance One Stop Virtualization Shop SQL Server HADR using Availability Groups and Failover Cluster Instance JUNE 2017 TECHNICAL PAPER Written by Shashank Singh Microsoft MVP (Data Platform), MCC and SQL Server

More information

StarWind Virtual SAN Windows Geo-Clustering: SQL Server

StarWind Virtual SAN Windows Geo-Clustering: SQL Server #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Windows Geo-Clustering: SQL Server FEBRUARY 2016 TECHNICAL PAPER EDWIN SARMIENTO, Microsoft SQL Server MVP, Microsoft Certified Master

More information

StarWind iscsi SAN Software: Getting Started with V5

StarWind iscsi SAN Software: Getting Started with V5 StarWind iscsi SAN Software: Getting Started with V5 www.starwindsoftware.com Copyright 2008-2009. All rights reserved. COPYRIGHT Copyright 2008-2009. All rights reserved. No part of this publication may

More information

StarWind iscsi SAN Software: Using StarWind to provide Cluster Shared Disk resources for Hyper-V Failover Clusters

StarWind iscsi SAN Software: Using StarWind to provide Cluster Shared Disk resources for Hyper-V Failover Clusters StarWind iscsi SAN Software: Using StarWind to provide Cluster Shared Disk resources for Hyper-V Failover Clusters www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright

More information

StarWind Hyper-Converged Platform: Data Sheet

StarWind Hyper-Converged Platform: Data Sheet Hardware-less VM Storage StarWind Hyper-Converged Platform: LAST UPDATED: MAY 2015 Trademarks StarWind, StarWind Software and the StarWind and the StarWind Software logos are registered trademarks of StarWind

More information

Vmware 3V VMware Certified Advanced Professional Data Center Virtualization Design.

Vmware 3V VMware Certified Advanced Professional Data Center Virtualization Design. Vmware 3V0-624 VMware Certified Advanced Professional 6.5 - Data Center Virtualization Design http://killexams.com/pass4sure/exam-detail/3v0-624 DEMO Find some pages taken from full version Killexams 3V0-624

More information

StarWind iscsi SAN Software: Virtual Tape Library (Part 1)

StarWind iscsi SAN Software: Virtual Tape Library (Part 1) StarWind iscsi SAN Software: Virtual Tape Library (Part 1) www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved. No part of this publication

More information

How to Deploy vcenter on the HX Data Platform

How to Deploy vcenter on the HX Data Platform First Published: 2016-07-11 Last Modified: 2019-01-08 vcenter on HyperFlex Cisco HX Data Platform deployment, including installation and cluster configuration and management, requires a vcenter server

More information

StoneFly SCVM Deployment Guide for VMware ESXi

StoneFly SCVM Deployment Guide for VMware ESXi StoneFly SCVM Deployment Guide for VMware ESXi Storage Concentrator Virtual Machine Software-Defined Virtual Storage Appliance Revision 2017.1 This Page is intentionally left blank. ENG-114 V 1.1 Copyright

More information

NexentaStor VVOL

NexentaStor VVOL NexentaStor 5.1.1 VVOL Admin Guide Date: January, 2018 Software Version: NexentaStor 5.1.1 VVOL Part Number: 3000-VVOL-5.1.1-000065-A Table of Contents Preface... 3 Intended Audience 3 References 3 Document

More information

StarWind Virtual SAN Installing and Configuring SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines

StarWind Virtual SAN Installing and Configuring SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines One Stop Virtualization Shop StarWind Virtual SAN Installing and Configuring SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines MARCH 2018 TECHNICAL PAPER Trademarks StarWind, StarWind

More information

Question No: 2 What three shares are available when configuring a Resource Pool? (Choose three.)

Question No: 2 What three shares are available when configuring a Resource Pool? (Choose three.) Volume: 70 Questions Question No: 1 A VMware vsphere 6.x Administrator sees the following output In esxtop: What does the %ROY column represent? A. CPU Cycle Walt Percentage B. CPU Utilization C. CPU Ready

More information

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

DSI Optimized Backup & Deduplication for VTL Installation & User Guide DSI Optimized Backup & Deduplication for VTL Installation & User Guide Restore Virtualized Appliance Version 4 Dynamic Solutions International, LLC 373 Inverness Parkway Suite 110 Englewood, CO 80112 Phone:

More information

PassTest. Bessere Qualität, bessere Dienstleistungen!

PassTest. Bessere Qualität, bessere Dienstleistungen! PassTest Bessere Qualität, bessere Dienstleistungen! Q&A Exam : VCP-510 Title : VMware Certified Professional on VSphere 5 Version : Demo 1 / 7 1.Which VMware solution uses the security of a vsphere implementation

More information

Exam4Tests. Latest exam questions & answers help you to pass IT exam test easily

Exam4Tests.   Latest exam questions & answers help you to pass IT exam test easily Exam4Tests http://www.exam4tests.com Latest exam questions & answers help you to pass IT exam test easily Exam : VCP510PSE Title : VMware Certified Professional 5 - Data Center Virtualization PSE Vendor

More information

StarWind Virtual SAN Installing and Configuring a SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines

StarWind Virtual SAN Installing and Configuring a SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines #1 HyperConverged Appliance for SMB and ROBO StarWind Virtual SAN Installing and Configuring a SQL Server Failover Clustered Instance on Microsoft Azure Virtual Machines AUGUST 2015 TECHNICAL PAPER BY

More information

Configuring and Managing Virtual Storage

Configuring and Managing Virtual Storage Configuring and Managing Virtual Storage Module 6 You Are Here Course Introduction Introduction to Virtualization Creating Virtual Machines VMware vcenter Server Configuring and Managing Virtual Networks

More information

VMware vsphere 6.0 / 6.5 Infrastructure Deployment Boot Camp

VMware vsphere 6.0 / 6.5 Infrastructure Deployment Boot Camp Title: Summary: Length: Overview: VMware vsphere 6.0 / 6.5 Infrastructure Deployment Boot Camp Class formats available: Live In-Classroom Training (LICT) Mixed class with Classroom and Online Instruction

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the

More information

StarWind iscsi SAN Software: Using StarWind Tape Redirector and CA ARCserve Backup

StarWind iscsi SAN Software: Using StarWind Tape Redirector and CA ARCserve Backup StarWind iscsi SAN Software: Using StarWind Tape Redirector and CA ARCserve Backup www.starwindsoftware.com Copyright 2008-2011. All rights reserved. COPYRIGHT Copyright 2008-2011. All rights reserved.

More information

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:

More information

VMware ESX ESXi and vsphere. Installation Guide

VMware ESX ESXi and vsphere. Installation Guide VMware ESX ESXi and vsphere Installation Guide UPDATED: 28 March 2018 Copyright Notices Copyright 2002-2018 KEMP Technologies, Inc. All rights reserved. KEMP Technologies and the KEMP Technologies logo

More information

Preparing the boot media/installer with the ISO file:

Preparing the boot media/installer with the ISO file: Preparing the boot media/installer with the ISO file: Download and extract the ISO file with your favorite uncompressing/extracting software (for example: 7zip or WinZip programs) to an empty USB Flash

More information

Developing a Complete RTO/RPO Strategy for Your Virtualized Environment

Developing a Complete RTO/RPO Strategy for Your Virtualized Environment #1 HyperConverged Appliance for SMB and ROBO Developing a Complete RTO/RPO Strategy for Your Virtualized Environment NOVEMBER 2014 WHITE PAPER BY GEORGE CRUMP Lead Analyst Storage Switzerland, LLC Virtualization,

More information

OneSign Virtual Appliance Guide

OneSign Virtual Appliance Guide OneSign Virtual Appliance Guide A OneSign Virtual Appliance is a self-contained software implementation of the OneSign server that is functionally equivalent to a OneSign hardware appliance. You host and

More information

Managing Virtual Machines

Managing Virtual Machines CHAPTER 6 Last Updated: September 17, 2012 A virtual machine is a software computer (just like a physical computer) that runs an operating system and applications. Virtual machines run on the VMware vsphere

More information

VMware vsphere 6.0 / 6.5 Advanced Infrastructure Deployment (AID)

VMware vsphere 6.0 / 6.5 Advanced Infrastructure Deployment (AID) Title: Summary: Length: Overview: VMware vsphere 6.0 / 6.5 Advanced Infrastructure Deployment (AID) Class formats available: Online Learning (OLL) Live In-Classroom Training (LICT) Mixed class with Classroom

More information

iscsi Configuration for ESXi using VSC Express Guide

iscsi Configuration for ESXi using VSC Express Guide ONTAP 9 iscsi Configuration for ESXi using VSC Express Guide May 2018 215-11181_E0 doccomments@netapp.com Updated for ONTAP 9.4 Table of Contents 3 Contents Deciding whether to use this guide... 4 iscsi

More information

Install ISE on a VMware Virtual Machine

Install ISE on a VMware Virtual Machine Supported VMware Versions, page 1 Support for VMware vmotion, page 1 Support for Open Virtualization Format, page 2 Virtual Machine Requirements, page 3 Virtual Machine Resource and Performance Checks,

More information

Configuring High Availability for VMware vcenter in RMS All-In-One Setup

Configuring High Availability for VMware vcenter in RMS All-In-One Setup Configuring High Availability for VMware vcenter in RMS All-In-One Setup This chapter describes the process of configuring high availability for the VMware vcenter in an RMS All-In-One setup. It provides

More information

Dell EMC vsan Ready Nodes for VDI

Dell EMC vsan Ready Nodes for VDI Dell EMC vsan Ready Nodes for VDI Integration of VMware Horizon on Dell EMC vsan Ready Nodes April 2018 H17030.1 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

StarWind iscsi Target for Microsoft Windows: Using StarWind iscsi Target and VMware Workstation Virtual Machines

StarWind iscsi Target for Microsoft Windows: Using StarWind iscsi Target and VMware Workstation Virtual Machines Using StarWind iscsi Target and VMware Workstation Virtual Machines May 1, 2007 Rocket Division Software www.rocketdivision.com Copyright Rocket Division Software 2001-2007. All rights reserved. Page 1

More information

Release Notes and User Guide DataCore vsphere Installation Manager 2.07

Release Notes and User Guide DataCore vsphere Installation Manager 2.07 Cumulative Change Summary Date 1.0 release Apr 18, 2016 Added direct link to VMware download site for Virtual Infrastructure extension (VIX) in Prerequisites Apr 21, 2016 1.1 release Jun 28, 2016 Added

More information

Getting Started with ESXi Embedded

Getting Started with ESXi Embedded ESXi 4.0 Embedded vcenter Server 4.0 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new edition. To check for more recent

More information

Server Fault Protection with NetApp Data ONTAP Edge-T

Server Fault Protection with NetApp Data ONTAP Edge-T Technical Report Server Fault Protection with NetApp Data ONTAP Edge-T Jeff Whitaker, NetApp March 2013 TR-4154 TABLE OF CONTENTS 1 Introduction... 3 2 Backup and Disaster Recovery Technology... 4 2.1

More information

Dell EMC Ready Architectures for VDI

Dell EMC Ready Architectures for VDI Dell EMC Ready Architectures for VDI Designs for VMware Horizon 7 on Dell EMC XC Family September 2018 H17387 Deployment Guide Abstract This deployment guide provides instructions for deploying VMware

More information

Vmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version :

Vmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version : Vmware VCP-511 VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version : http://killexams.com/pass4sure/exam-detail/vcp-511 in RAM. A virtual machine running completely in RAM performs

More information

VMware vsphere 5.5: Install, Configure, Manage Lab Addendum. Lab 3: Configuring VMware ESXi

VMware vsphere 5.5: Install, Configure, Manage Lab Addendum. Lab 3: Configuring VMware ESXi VMware vsphere 5.5: Install, Configure, Manage Lab Addendum Lab 3: Configuring VMware ESXi Document Version: 2014-07-08 Copyright Network Development Group, Inc. www.netdevgroup.com NETLAB Academy Edition,

More information

Installation and Cluster Deployment Guide

Installation and Cluster Deployment Guide ONTAP Select 9 Installation and Cluster Deployment Guide Using ONTAP Select Deploy 2.3 March 2017 215-12086_B0 doccomments@netapp.com Updated for ONTAP Select 9.1 Table of Contents 3 Contents Deciding

More information

Installation and Configuration. Horizon Cloud 1.3 with Pivot3 Hyperconverged Infrastructure

Installation and Configuration. Horizon Cloud 1.3 with Pivot3 Hyperconverged Infrastructure Horizon Cloud 1.3 with Pivot3 Hyperconverged Infrastructure August 2017 Copyright 2016, 2017 VMware, Inc. All rights reserved. This product is protected by U.S. and international copyright and intellectual

More information

Archiware Pure Quick Start Guide

Archiware Pure Quick Start Guide Archiware Pure Quick Start Guide Content 1 System Requirements... 3 1.1 Hardware Requirements... 3 1.2 Supported Hypervisors... 3 1.3 Deployment Requirements... 3 2 Deploying the Virtual Appliance... 4

More information

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x

Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Using EonStor DS Series iscsi-host storage systems with VMware vsphere 5.x Application notes Abstract These application notes explain configuration details for using Infortrend EonStor DS Series iscsi-host

More information

VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ]

VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ] s@lm@n VMware Exam VCP-511 VMware Certified Professional on vsphere 5 Version: 11.3 [ Total Questions: 288 ] VMware VCP-511 : Practice Test Question No : 1 Click the Exhibit button. An administrator has

More information

Preparing Virtual Machines for Cisco APIC-EM

Preparing Virtual Machines for Cisco APIC-EM Preparing a VMware System for Cisco APIC-EM Deployment, page 1 Virtual Machine Configuration Recommendations, page 1 Configuring Resource Pools Using vsphere Web Client, page 4 Configuring a Virtual Machine

More information

Basic Configuration Installation Guide

Basic Configuration Installation Guide EMC RecoverPoint for VMs 5.0 Basic Configuration Installation Guide P/N 302-003-534 REV 01 December 7, 2016 This document contains information on these topics: Revision History... 2 Overview... 3 Reference

More information

Preparing Virtual Machines for Cisco APIC-EM

Preparing Virtual Machines for Cisco APIC-EM Preparing a VMware System for Cisco APIC-EM Deployment, on page 1 Virtual Machine Configuration Recommendations, on page 1 Configuring Resource Pools Using vsphere Web Client, on page 4 Configuring a Virtual

More information