TECHNICAL DOCUMENT. LS-8015-MM-ZW Z-wave Wireless Door Lock Technical Manual. Version Release Date Written By Reviewed By Approved By
|
|
- Penelope Hodge
- 5 years ago
- Views:
Transcription
1 TECHNICAL DOCUMENT LS-8015-MM-ZW Z-wave Wireless Door Lock Technical Manual Version Release Date Written By Reviewed By Approved By September 9, 2013
2 Table of Contents 1 Overview Z-wave Specification Device Class Flirs Setting Support Command Class Z-wave SDK Version compatibility Technical Description Secure vs no-secure Manufacture Specific Command Class Anti-theft Command Class COMMAND_CLASS_APPLICATION_STATUS COMMAND_CLASS_ASSOCIATION COMMAND_CLASS_CONFIGURATION COMMAND_CLASS_DOOR_LOCK COMMAND_CLASS_NODE_NAMING COMMAND_CLASS_SCHEDULE_ENTRY_LOCK COMMAND_CLASS_USER_CODE... 5
3 Revision History Revise Record Ver Brief description of change Date Approved by 1.0 Initial Release :04:00 1
4 1 Overview Locstar Z-Wave electrical keypad door lock lever secures your home with a new level of functionality that provides security and convenience and is completely integrated with the Z-Wave system. The lock can wirelessly talk to other things in your house, such as the security system, lighting, thermostat, and entertainment system. Lock becomes the first point of contact for security and home control on any door the lock is installed. You'll be able to stop fumbling around with keys just to unlock your door and never have to worry about being locked out again. 2 Z-wave Specification 2.1 Device Class - Generic Device Command Class = GENERIC_TYPE_ENTRY_CONTROL - Specific Device Command Class = SPECIFIC_TYPE_SECURE_KEYPAD_DOOR_LOCK 2.2 Flirs Setting - APPLICATION_FREQ_LISTENING_MODE_1000ms 2.3 Support Command Class - COMMAND_CLASS_ANTITHEFT - COMMAND_CLASS_MANUFACTURER_SPECIFIC - COMMAND_CLASS_VERSION - COMMAND_CLASS_SECURITY - COMMAND_CLASS_ASSOCIATION - COMMAND_CLASS_APPLICATION_STATUS - COMMAND_CLASS_BASIC - COMMAND_CLASS_BATTERY - COMMAND_CLASS_DOOR_LOCK - COMMAND_CLASS_DOOR_LOCK_LOGGING - COMMAND_CLASS_NODE_NAMING - COMMAND_CLASS_SCHEDULE_ENTRY_LOCK - COMMAND_CLASS_TIME_PARAMETERS - COMMAND_CLASS_USER_CODE 2.4 Z-wave SDK Version compatibility - Z-wave SDK :04:00
5 Since Z-wave has adapted continues send out Security Nonce Get, Security Nonce Report and Security Message Encapsulation Command instead of send out wakeup beam every time to improve Flirs secure device communication effective from SDK , recommend include this device into controller under SDK version to ensure device working properly while CTT test or in application environment. 3 Technical Description 3.1 Secure vs no-secure The Door Lock is a security enabled Z-wave production, implements Z-Wave Application Security Layer in accordance with Z-wave protocol. The functionality and support command class is difference when included as secure or no-secure node. COMMAND_CLASS_DOOR_LOCK and COMMAND_CLASS_USER_CODE command class will not support while door lock included in no-secure controller. 3.2 Manufacture Specific Command Class Door Lock manufactures information as following: - MANUFACTURER_ID1 0x01 - MANUFACTURER_ID2 0x5E - PRODUCTIONTYPE_ID1 0x80 - PRODUCTIONTYPE_ID2 0x15 - PRODUCTION_ID1 0x00 - PRODUCTION_ID2 0x Anti-theft Command Class Please be noted that the door lock only supports Anti-theft command class version 2 due to security command data length limited and it effect Z-wave command access only while anti-theft function enabled. If door lock anti-theft function was enabled by exclude from no-secure controller improperly, it should be re-included in no-secure controller to disable anti-theft function. If door lock anti-theft function was enabled by exclude from secure controller improperly, it should be re-included in secure controller to disable anti-theft function similarly. If door lock anti-theft function was enabled by exclude from no-secure controller improperly, it supports COMMAND_CLASS_ANTITHEFT, COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_VERSION no-secure command class only :04:00 3
6 If door lock anti-theft function was enabled by exclude from secure controller improperly, it supports COMMAND_CLASS_MANUFACTURER_SPECIFIC, COMMAND_CLASS_VERSION command class only and security command support COMMAND_CLASS_ANTITHEFT only. 3.4 COMMAND_CLASS_APPLICATION_STATUS Door lock responses Application Rejected Request Command to source node while received invalid Set command. 3.5 COMMAND_CLASS_ASSOCIATION Door lock supports two(2) association groups, each group support two(2) nodes maximum. Group ID one(1) used to send out un-socialite operation and alarm reports. Group ID two(2) used to send out BASIC SET ON(0xFF) and OFF(0x00) command while vacation mode is enable and disable. 3.6 COMMAND_CLASS_CONFIGURATION Door lock reserves 255 bytes memory store space use for upper application. Upper application could access the memory by configuration command class, default setting always set to zero (0x00). 3.7 COMMAND_CLASS_DOOR_LOCK Door lock has two(2) difference relock mode, auto-relock mode (Timed Operation) and constant-unlock mode (Constant Operation). It can setting by manual or Door Lock Configuration Command. Auto-relock timeout fix in eight (8) seconds. Door lock treats constant Unsecure setting of Door Lock Operation as Unsecure with timeout while device auto-relock mode is enable. Please be noted that, since door lock takes around one(1) second to complete unlock and re-lock and configuration setting operation, it should insert a one second waiting delay before send out next Z-wave command while CTT test or application environment. 3.8 COMMAND_CLASS_NODE_NAMING Door lock report Node Name Report in ASCII with brand name and production version inform after retrieve factory default. Factory default is Locstar Ver x.xx, x is base on actually version number. 3.9 COMMAND_CLASS_SCHEDULE_ENTRY_LOCK :04:00
7 Door lock doesn t support Daylight Saving function. It will ignore DST offset of Schedule Entry Lock Time Offset Set Command. Door lock supports Duration Hour of Schedule Entry Lock Daily Repeating Set command from zero (0) to 168 (=7x24) maximum COMMAND_CLASS_USER_CODE Door lock user code fix to six(6) digits. It will ignore User Code Set Command if user code length no equal to six digits :04:00 5
8
9
Benetek Smart Hidden Door Lock v5.1
Benetek Smart Hidden Door Lock v5.1 I.Product Introduction Thank you for choosing the Benetek premium Smart Hidden Door Lock (SHDL)! The smart lock has adopted the latest Z-Wave smart home technology along
More informationYale Locks. Z-Wave Plus System Integrators Guide. Yale Real Living Electronic Deadbolts. Document Revision: 4. August 23, 2016
Yale Locks Z-Wave Plus System Integrators Guide Yale Real Living Electronic Deadbolts Document Revision: 4 August 23, 2016 1 Contents Yale Z-Wave+ Product Info... 3 Network Operations... 3 Enroll/Add device
More informationSoftware Design Specification Document SDS List of defined Z-Wave Command Classes.
Software Design Specification Document SDS13548 - List of defined Z-Wave Command es. This document lists the existing Command es, commands and their associated metadata. DOCUMENTATION DISCLAIMER Copyright
More informationQuick start: Panic Watch EU
Quick start: Panic Watch EU Technical specifications Normal operating voltage Battery lifetime Frequency range Wireless range 1x CR2450 3V battery Min 3 till 5 years 868.42 MHz EU Min. 30 meters in line
More informationZ-Wave Home Gateway. FG3200/FG2200 ( Z-Wave Home gateway )
Z-Wave Home Gateway FG3200/FG2200 ( Z-Wave Home gateway ) Index INDEX... 0 INTRODUCE... 1 PRODUCT DESCRIPTION AND SPECIFICATION... 2 PACKAGE CONTENTS... 3 ICON AND COMMAND CLASSES... 3 CONNECTION:... 7
More informationsmanos K2 Smart Hub Contents
smanos K2 Smart Hub The DUT (K2 hub) is a security enabled Z-Wave Plus product that is able to use encrypted Z-Wave Plus messages to communicate to other security enabled Z-Wave Plus products. Please refer
More informationDanalock Product manual
Danalock Product manual The Danalock is a secure electronic door lock that supports the Z-Wave Plus standard, which is compatible with earlier versions of Z-Wave. The Danalock is battery supplied and therefore
More informationAeon Labs Dual Nano Switch
Aeon Labs Dual Nano Switch (Z-Wave Dual Nano Switch) Page 1 Change history Revision Date Change Description 1 7/25/2016 Initial draft. 2 9/08/2016 Update 3 10/11/2016 Update 4 12/01/2016 Update 5 12/17/2016
More informationPACKAGE CONTENTS SPECIFICATIONS
PACKAGE CONTENTS After receiving the product, please inventory the contents to ensure you have all the proper parts, as listed below. If anything is missing or damaged, please contact Monoprice Customer
More informationAeon Labs Micro Smart Dimmer (2nd Edition) (Z Wave Micro Smart Dimmer (2nd Edition))
Aeon Labs Micro Smart Dimmer (2nd Edition) (Z Wave Micro Smart Dimmer (2nd Edition)) Document No: Version: 1 Description: The purpose of this document is to provide guidelines for the user and application
More informationAeon Labs Dual Nano Switch
Aeon Labs Dual Nano Switch (Z-Wave Dual Nano Switch) Page 1 Change history Revision Date Change Description 1 7/25/2016 Initial draft. 2 9/08/2016 Update 3 10/11/2016 Update 4 12/01/2016 Update 5 12/17/2016
More informationAeon Labs Doorbell Gen5 (Z Wave Doorbell Gen5)
Aeon Labs Doorbell Gen5 (Z Wave Doorbell Gen5) Change history Revision Date Change Description 1 01/22/2015 Initial draft. 2 02/04/2015 Aeon Labs Doorbell Gen5 Engineering Specifications and Advanced Functions
More informationSoftware Design Specification
Software Design Specification User Code Command Class, version 2 Document No.: SDS13615 Version: 1 Device Class Ver 0.9 Description: - Written By: NOBRIOT Date: Reviewed By: Restrictions: NOBRIOT;JFR;COLSEN;JROSEVALL;YANYAN;DCHOW
More informationAeon Labs LED Strip. (Z-Wave LED Strip)
Aeon Labs LED Strip (Z-Wave LED Strip) Change History Revision Date Change Description 1 04/19/2016 Initial draft. 2 04/25/2016 Update 3 05/06/2016 Update 4 05/20/2016 Update Aeon Labs LED Strip Engineering
More informationAeon Labs Nano Switch
Aeon Labs Nano Switch (Z-Wave Nano Switch) Page 1 Change history Revision Date Change Description 1 8/22/2016 Initial draft. 2 10/11/2016 Update 3 11/08/2016 Update 4 12/07/2016 Update 5 12/17/2016 Update
More informationAeon Lab a s b LED Bu B lb
Aeon Labs LED Bulb (Z-Wave LED Bulb) Change History Revision Date Change Description 1 03/24/2015 Initial draft. 2 07/06/2015 Update 3 04/25/2016 Update 4 06/20/2016 Update 5 8/25/2017 Update Aeon Labs
More informationDoor Lock PSA01. I. Specification/Function
Door Lock PSA01 I. Specification/Function 1. Battery 1-1 Four AA (1.5V) Alkaline batteries. 2. Low Battery 2-1 The batteries should be changed immediately once you see the LED flash red and hear constant
More informationNorthQ Power Reader (NQ-9021) Technical Integration. Z-Wave Commands
NorthQ Power Reader (NQ-9021) Technical Integration Z-Wave Commands Table of Contents Power Reader NQ-9021 Power Reader...1 Overall device information...2 General description...2 Command classes supported...2
More informationQuick start: Tag Reader EU
Quick start: Tag Reader EU Technical specifications Normal operating voltage Frequency range Wireless range Protocols supported Buzzer-sound Z-Wave frames encapsulated x AA,5V batteries 868. MHz Up to
More informationAeon Labs Range Extender 6. (Z-Wave Range Extender)
Aeon Labs Range Extender 6 (Z-Wave Range Extender) Change history Revision Date Change Description 1 5/31/2016 Initial draft. Aeon Labs Range Extender 6 Engineering Specifications and Advanced Functions
More informationAeon Labs LED Bulb. (Z-Wave LED Bulb)
Aeon Labs LED Bulb (Z-Wave LED Bulb) Change History Revision Date Change Description 1 03/24/2015 Initial draft. 2 07/06/2015 Update 3 04/25/2016 Update to V1.05 4 06/20/2016 Update Aeon Labs LED Bulb
More informationAeon Labs LED Bulb (Z-Wave LED Bulb)
Aeon Labs LED Bulb (Z-Wave LED Bulb) Change History Revision Date Change Description 1 03/24/2015 Initial draft. 2 06/02/2015 Update 3 06/17/2015 Update Aeon Labs LED Bulb Engineering Specifications and
More informationQuick start Energy Switch EU
Technical specs Normal operating voltage 230V/50Hz Quick start Energy Switch EU Recommended max load 3000W 600W Frequency range Wireless Range Energy measurement 868.42 MHz Up to 30m line of sight 1 3600W
More informationZ-Wave AC Motor Shutter Controller
Works with: MI CASA VERDE VERA NEVO AEON LABS mcontrol ADT Pulse Z-Wave AC Motor Shutter Controller DHS-ZW-TMC-01 User Guide Z-Wave Technology for Automated Homes Z-Wave is a state of-the-art wireless
More informationAeon Labs Nano Dimmer
Aeon Labs Nano Dimmer (Z-Wave Nano Dimmer) Page 1 Change history Revision Date Change Description 1 08/10/2016 Initial draft. 2 10/20/2016 Update 3 10/28/2016 Update 4 10/31/2016 Update 5 11/01/2016 Update
More informationOPERATING MANUAL. NanoMote Quad ZWA003-A/C
OPERATING MANUAL NanoMote Quad ZWA003-A/C NanoMote Quad is a wireless, portable and rechargeable product. On one hand, it can be used to control separate Z-Wave device, such as a smart Plug, smart Dimmer,
More informationAeon Labs Smart Switch 6 (Z-Wave Smart Switch 6)
Aeon Labs Smart Switch 6 (Z-Wave Smart Switch 6) Change history Revision Date Change Description 1 3/30/2015 Initial draft. 2 6/1/2015 Update 3 6/10/2015 Update 4 7/02/2015 Update LED indication Aeon Labs
More informationZ-Wave Power Reader. Product Manual NQ-9021-EU. From your Z-wave network directly to the cloud! INTRODUCTION
Product Manual NQ-9021-EU Z-Wave Power Reader From your Z-wave network directly to the cloud! INTRODUCTION NorthQ Power has developed a samll Power Reader that can be easily installed on existing electronic
More informationUniversal Z-Wave Key Pad
POPP Universal Z-Wave Key Pad SKU: POPE700045 Quickstart This is a secure Keypad for Europe. To run this device please insert fresh 4 * AAA batteries. Please make sure the internal battery is fully charged.
More informationPACKAGE CONTENTS SPECIFICATIONS PRODUCT DIAGRAM
PACKAGE CONTENTS After receiving the product, please inventory the contents to ensure you have all the proper parts, as listed below. If anything is missing or damaged, please contact Monoprice Customer
More informationSHS-P710. Samsung SDS Door Lock
SHS-P710 Samsung SDS Door Lock User and Reference Guide Ver1.0.0 This manual was prepared for the certification test. Product Specifications Item Exterior Unit Size Interior Unit Voltage Emergency Power
More informationSHP-DH520. Samsung SDS Door Lock
SHP-DH520 Samsung SDS Door Lock User and Reference Guide Ver1.0.0 Product Specifications Item Exterior Unit Size Interior Unit Voltage Emergency Power Source Battery Life Support Card Standard Spec. 77.4mm(W)
More informationZ-Wave.Me Key Chain Controller
Z-Wave.Me Key Chain Controller ZME_KFOB Firmware Version 1.0, Cert-Id: ZC08-12070010 1 What is Z- Wave? This device is equipped with wireless communication that complies to the Z-Wave standard. Z-Wave
More informationAdding to Z-Wave TM Network
TZ06 In Wall Dual relay(1 way) switch module kind of light like incandescent, fluorescent and LED light. This module can also connect to alternative power supply like DC 12V to switch on/off 12V MR-16
More informationUniversal Z-Wave Key Pad
Universal Z-Wave Key Pad SKU: POPE700045 Quickstart This is a secure Kepad for Europe. To run this device please insert fresh 4 * AAA batteries. Please make sure the internal battery is fully charged.
More informationHUB 2 HUB 2. Z-Wave Integration Manual. Wink HUB 2 - Z-Wave integration - October 1,
HUB 2 HUB 2 Z-Wave Integration Manual Wink HUB 2 - Z-Wave integration - October 1, 2016 1 HUB 2 TABLE OF CONTENTS CONNECTING WINK HUB 2 WINK HUB 2 Z-WAVE CONTROLS 1. Learn Mode 2. Controller Reset 3. Controller
More informationID Lock ID Lock 150 User Reference Manual Rev 2.1
1 Table of Contents 1 Introduction... 4 2 Overview... 4 3 Getting started... 5 3.1 How to see if your ID Lock is a 101 or 150... 5 3.2 ID Lock 101... 6 3.3 ID Lock 150... 7 4 Z-wave Specifications... 8
More informationGetting Started. Gateway Activation Process. Gateway Descriptions
Intrusion Getting Started G100 Z-Wave gateway Getting Started The G100 is a Z-Wave gateway that supports home automation devices within a Z-Wave ecosystem. Home automation devices are added to the network,
More informationAeon Labs Water Sensor 6
Aeon Labs Water Sensor 6 (Z-Wave Water Sensor) Page 1 Change history Revision Date Change Description 1 01/05/2017 Initial draft. 2 03/28/2017 Update 3 04/07/2017 Update 4 04/27/2017 Update Page 2 Aeon
More informationGetting Started. Activation Process. G450 Overview
ntrusion Started G450 Home Control Gateway Getting Getting Started This Home Control Gateway is a controller that supports home automation devices within a Home Control ecosystem. Home automation devices
More informationContent. Chapter 1 Features
User Manual of Access Control Panel Content Chapter 1 Features... 1 Chapter 2 Parameters (case: ABS-1)... 2 Chapter 3 Function Introduction... 2 Chapter 4 Application... 3 Chapter 5 Access control panel
More informationElectronic Solutions, Inc.
Electronic Solutions, Inc. ABMHZ 115 908, ABMHZ 115 868 1. Introduction This document is for the advanced user who has knowledge of the Z-Wave Command Classes and is able to initiate Z-Wave commands programmatically.
More informationSI-103. Flood Sensor. User Manual
SI-103 Flood Sensor User Manual Copyright and Disclaimer Copyright & Disclaimer No part of this publication may be reproduced in any form or by any means, whether electronic, mechanical, photocopying,
More informationZ-Wave CO Detector. Product Description. Prepare for Installation / Reset Please read the user manual before installing the product.
Z-Wave CO Detector SKU: POPE004407 Quickstart This is a secure Z-Wave Device for Europe. To run this device please insert fresh 1 * CR14250 batteries. Please make sure the internal battery is fully charged.
More informationMicro Dimmer MH-P220. *Note: For non-resistive load, a derating output is highly suggested.
Micro Dimmer MH-P220 Introduction. Micro Dimmer is a Z-Wave Plus enabled in-wall module which can be wired with a wall switch panel. It supports basic command class, and also can act as a repeater in Z-Wave
More informationInstruction Manual Power plug Model number: STW-W3350WU
Instruction Manual Power plug Model number: STW-W3350WU Thank you for your support Please read the instruction manual carefully before operating Please keep the instruction manual for future reference
More informationTABLE OF CONTENTS (continued) TABLE OF CONTENTS. March 2006
PK3173 0306 TABLE OF CONTENTS States of the Lock........................................4 Factory Mode..........................................4 Access Mode..........................................4
More information2. Press Fn switch 3 times in a row again to exclude the device from Z-Wave network.
Repeater Manual The name of each part AC Outlet Multi Function Button AC outlet state LED Z-Wave state LED Functional Instruction. AC voltage measurement (V, A, Watt, PF). Z-Wave network ADD and remove
More informationTroubleshooting: Locked Turnbutton 6. Troubleshooting: Keypad 7. Troubleshooting: Smart Home Systems 8. Troubleshooting: Battery 10.
Programming and Troubleshooting Guide 1 2 3 4 5 6 Mastercode 2 Troubleshooting: Locked Turnbutton 6 Troubleshooting: Keypad 7 Troubleshooting: Smart Home Systems 8 Troubleshooting: Battery 10 Battery FAQ
More informationZ-Wave Control Network. Introducing the next-generation wireless solution to integrate home electronics and systems
Z-Wave Control Network Introducing the next-generation wireless solution to integrate home electronics and systems Overview Z-Wave LCD Remote Control Controls the entire Z-Wave lighting control network
More informationIWATSU 3G Gateway. Instruction Manual
IWATSU 3G Gateway Smart-BRIDGE C3 Instruction Manual Page 1 1 Introduction Smart-BRIDGE C3 is a Z-Wave controller to enable interaction with homes, offices and buildings. It can collect sensor data and
More informationAdding to Z-Wave TM Network 1
This plug-in ON/OFF switch PAN11 is a wireless switch, based on Z-Wave technology. Z-Wave TM enabled devices displaying the Z-Wave TM logo can also be used with it regardless of the manufacturer, and can
More informationOperational Manual for ID Lock 101 with Z-Wave Module 01A
Operational Manual for ID Lock 101 with Z-Wave Module 01A Operational Manual - Z-Wave module board 01A - For ID Lock -101 series Door locks v1.3 English released 08.05.2017 Getting started IMPORTANT: Batteries
More informationDL2700-SERIES DIGITAL LOCKS Programming Instructions
DL2700-SERIES DIGITAL LOCKS Programming Instructions If a wrong code is entered, the red LED will flash 5 times. If the batteries are weak, pressing any button will cause the red LED to come on, along
More informationCO-100. Offline lock user guide Instructions for CO-Series offline locks
P516-270 CO-100 Offline lock user guide Instructions for CO-Series offline locks Para el idioma español, navegue hacia us.allegion.com. Pour la portion française, veuillez consulter le site us.allegion.com.
More informationSoftware Design Specification
Software Design Specification Z-Wave Plus Device Type Specification Document No.: SDS11847 Version: 16 Description: This document defines the Z-Wave Plus Device Types, which specify how a Z- Wave Plus
More informationUSER GUIDE for ios 1
USER GUIDE for ios 1 CONTENTS GETTING STARTED 3 DOWNLOAD THE SECURESMART APP 3 LOGIN 3 DASHBOARD 4 MENU 5 SETTING UP TOUCH ID 6 USING THE APPLICATION 7 SECURITY SYSTEM KEYPAD 7 HOME AUTOMATION 8 VIEWING
More informationPlease refer to the chapters below for detailed information about all aspects of the products usage.
EVR_AN1812 Z-Wave mini Plug with metering Firmware Version : 1.1 Quick Start S To include the device press the button at the plug three times within 1.5 seconds. Please refer to the chapters below for
More informationDCH-122 PIR Motion Sensor
DCH-122 PIR Motion Sensor Better RF range, improve about 10 meters in indoor. Support 100 Kbps transmit speed, speed up communication. Add to/remove from Z-Wave TM Network There are two tamper keys in
More informationOPERATING INSTRUCTIONS AUDITCON LOCK 100, 200, 400, 500 SERIES
OPERATING INSTRUCTIONS AUDITCON LOCK 100, 200, 400, 500 SERIES Trademarks The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries: Auditcon PowerSaver
More informationSoftware Design Specification
Software Design Specification Z-Wave Plus v2 Device Type Specification Document No.: SDS14224 Version: 4 Description: - Written By: NOBRIOT;DEWASSIE Date: 2018-10-08 Reviewed By: Restrictions: NOBRIOT;JFR;BBR;NTJ;COLSEN;PSH;JRM;SAMBAT;YANYAN;DCHOW
More informationCO-100 OFFLINE LOCK USER GUIDE
P516-270 CO-100 OFFLINE LOCK USER GUIDE INSTRUCTIONS FOR CO-SERIES OFFLINE LOCKS Para el idioma español, navegue hacia www.schlage.com/support. Pour la portion française, veuillez consulter le site www.schlage.com/support.
More informationOPERATING INSTRUCTIONS
AUDITCON 2 SEIES MODELS 252 & 552 OPEATING INSTUCTIONS Lock Modes A lock is shipped from the factory with default lock setup values and a pre-set PIN for unlocking the lock. This is referred to as Factory
More informationPlease refer to the chapters below for detailed information about all aspects of the products usage.
EVR_AN1802 Z-Wave mini Plug Firmware Version : 1.2 Quick Start S To include the device press the button at the plug three times within 1.5 seconds. Please refer to the chapters below for detailed information
More informationVal Living. L1 Manual. Conexis. smart. The Secure, Keyless Smart Door Lock. Yale. T W ASSA.ABLOY
smart Val Living Yale 0 Conexis L Manual The Secure, Keyless Smart Door Lock. ASSA.ABLOY An ASSA ABLOY Group brand T 04 474 W www.windowware.co.uk Discover Our Range of Products Yale Connected Secure,
More informationSoftware Design Specification
Software Design Specification Z-Wave Plus Device Type Specification Document No.: SDS11847 Version: 25 Description: This document defines the Z-Wave Plus Device Types, which specify how a Z- Wave Plus
More informationE-PLEX 58XX FIPS LOCK SERIES OPERATIONS MANUAL
E-PLEX 58XX FIPS LOCK SERIES OPERATIONS MANUAL TABLE OF CONTENTS Definition of the term LearnLok...............................4 States of the E-Plex Lock.......................................4 Factory
More informationAEO_HDS Heavy Duty Switch
AEO_HDS Heavy Duty Switch Firmware Version : 1.14 Quick Start A This device is a Z-Wave Actuator. Single click the button inside the casing to include or exclude the device. If the Aeon Labs Heavy Duty
More informationVIS_ZM1602 Wireless Siren - mainspowered
Image not readable or empty images/manufacturers/vision.png VIS_ZM1602 Wireless Siren - mainspowered Firmware Version : 1.65 Quick Start A This device is a wireless Z-Wave actor. For Inclusion and Exclusion
More informationliving connect, Z-Wave Certified Electronic Radiator
living connect, Z-Wave Certified Electronic Radiator Thermostat Application living connect is battery powered, compact and very easy to operate with only three buttons on the front. This documents provides
More informationPlease refer to the chapters below for detailed information about all aspects of the products usage.
AEO_ZW089 Recessed Door Sensor Firmware Version : 1.12 Quick Start S This device is a Z-Wave Sensor. Single click the Z-Wave button on the device with a small pin to include or exclude the device. Clicking
More informationHome Monitoring and Control service provided by Verizon Online LLC
Home Monitoring and Control service provided by Verizon Online LLC A separate subscription to Verizon FiOS TV is required for use with FiOS TV service. About This Manual This manual is designed for online
More informationMULTIREG Z-WAVE SCENE CONTROLLER
MULTIREG Z-WAVE SCENE CONTROLLER Installers manual Z-Wave coupler module for GIRA installations Firmware 1.0 01.02.2017 The device can work in different modes and with different functionalities which may
More informationLock Parts. Keys. Key Insertion. Front Unit. Rear Unit. Product Guide. Standard Keypad Bolt Mechanism. Connection Options
Axis locks with a keypad interface are operated by a 4-digit User Code or by an ADA compliant User Key. Manager Keys provide management access and external power. Programming is accomplished via a Programming
More informationZ-Wave British Standard Plug Dimmer
Popp Z-Wave British Standard Plug Dimmer SKU: POP_123603 Quickstart This is a Light Dimmer for Europe. To run this device please connect it to your mains power supply. What is Z-Wave? Z-Wave is the international
More informationLock Orientation - Views. Keys. Key Insertion. Product Guide. Keypad Key Managed. Horizontal - Handle on Right. Vertical
Sola locks with a keypad interface are operated by a -digit User Code or by an ADA compliant User Key. Manager Keys provide management access and external power. Programming is accomplished via a Programming
More informationCarrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications
Carrier ComfortChoice Touch ZigBee Certified Thermostat Technical Specifications Physical & Operational Characteristics Height 4.75 Width 5.5 Thickness (Stacked) 1.3 Thickness (User Interface, Un-stacked)
More informationManual. The Secure, Keyless Smart Door Lock. The smarter way to protect your home
Conexis L Manual The Secure, Keyless Smart Door Lock The smarter way to protect your home Discover Our Range of Products Yale Connected Secure, monitor and control your home with a range of smart security
More informationPOP_ Z-Wave Schuko Plug-in Switch plus Power Meter Firmware Version : 1.1
POP_123658 Z-Wave Schuko Plug-in Switch plus Power Meter Firmware Version : 1.1 Quick Start A This device is a Z-Wave Actor. Tripple click the button on the device confirms the inclusion, exclusion and
More informationPOPE Z-Wave 10 Year Smoke Detector with Siren Function
POPE009402 Z-Wave 10 Year Smoke Detector with Siren Function Firmware Version : 1.0 Quick Start S This device is a combination of a Z-Wave sensor (smoke sensor) and a Z-Wave actuator. Pressing the 'Inclusion
More informationAdding to Z-Wave TM Network
PAN04-1/-2/-3 In Wall Dual relay(1 way) switch module Off, one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let
More informationZME_RC2 Z-Wave Remote Control
ZME_RC2 Z-Wave Remote Control Firmware Version : 1.1 Quick Start S This device is a Z-Wave Remote Control with the logical function of a sensor. Push the "Include" button behind the slider on the back
More informationStrike Lock Control. Prepare for Installation / Reset Please read the user manual before installing the product.
Strike Lock Control SKU: POPE012501 Quickstart This is a secure Door Lock for Europe. To run this device please insert fresh 1 * 9V Block batteries. Please make sure the internal battery is fully charged.
More informationPAD02. Z-Wave Smart Dimmer Socket. Adding to Z- Wave TM Network
PAD02 Z-Wave Smart Dimmer Socket PAD02 is an E27(EU)/ E26(US) Edison screw based lamp socket, which provides electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and support it in the
More informationLumina Version 3.0 Firmware Release
Lumina Version 3.0 Firmware Release ADD THIS DOCUMENT TO YOUR LUMINA ADVANCED APPLICATION GUIDE Description The Lumina Version 3.0 firmware adds the following new features: UPB Transmit Count to increase
More informationNetworked Door Strike Relay Message Format Specification A
Networked Door Strike Relay Message Format Specification 011270A SHEET 1 Revision History Revision Date Description A 4/9/2014 This is the first release. B 10/15/2014 Updates Section 1.0, "Overview" Updates
More informationPHI_PAN06 Relay Insert 2 * 1.5 KW
PHI_PAN06 Relay Insert 2 * 1.5 KW Firmware Version : 1.0 Quick Start A This device is a Z-Wave Actor. Tripple Click the Button on the device confirms the inclusion, exclusion and association. After power
More informationAXIS T8341 PIR Motion Sensor. User Manual
User Manual Table of Contents Solution overview........................................... 3 Product overview........................................... 4 How to add a device to a Z-Wave Network......................
More informationEBV105 Quick Start Guide
EBV105 Quick Start Guide Specifications The EBV105 Z-Wave Valve Controller requires 12V DC input at 1Amp (AC to DC Adapter included). The EBV105 can be paired with, and controlled using any Z-Wave compatible
More informationClay Tablet Connector for Adobe Experience Manager. User Guide. Version 2.3.0
Clay Tablet Connector for Adobe Experience Manager User Guide Version 2.3.0 March 9, 2015 Copyright Copyright 2005-2015 Clay Tablet Technologies Inc. All rights reserved. All rights reserved. This document
More informationZ-WavePlus Siren Installation Instructions
Z-WavePlus Siren Installation Instructions Product Overview Z-Wave Plus enabled device which can be used to alert the user. Able to produce 4 different notification sounds Volume control located on the
More informationCO-250. Offline lock user guide Instructions for programming CO-Series offline locks
*P516-272* P516-272 CO-250 Offline lock user guide Instructions for programming CO-Series offline locks Para el idioma español, navegue hacia www.allegion.com/us. Pour la portion française, veuillez consulter
More informationPC180 MODBUS COMMUNICATION MANUAL INJECTION MANAGEMENT SYSTEM
PC180 MODBUS COMMUNICATION MANUAL INJECTION MANAGEMENT SYSTEM Modbus is a trademark of Modicon, Inc. Manual content copyright 2015 Extreme Telematics Corporation. All Rights Reserved. Ver 3.2 10/07/15
More informationDigital Lock User Guide
Digital Lock User Guide KEYPAD Keypad digital locks are operated by a 4-7 digit User Code. Manager Keys provide management access and external power. Programming is accomplished via a Programming Key unique
More informationtime. This feature saves time and cost of the personal. their various attendance and leave details.
Leave Requests and Approvals With just a single click of the mouse, employees instantly submit their leave request and those requests are routed to reporting officer and HR's window. Reporting office or
More informationThe RS-485 user manual for B800 series communication
The user manual of B800 Series Rs-485 The RS-485 user manual for B800 series RS-232 inbuilt inside the main board of B800 series frequency inverter, we can effect RS-485 through fitting board externally.
More informationProduct Guide. Key Button. Pull Handle
Aspire locks with a keypad interface are operated by a 4-7 digit User Code or by an ADA compliant User Key. Manager Keys provide management access and external power. Programming is accomplished via a
More informationUSERS MANUAL FOR PROGRAMMING THE MOB.IQ EZRS, EZRS2 MOTORS
PROGRAMMING BUTTION USERS MANUAL FOR PROGRAMMING THE MOB.IQ EZRS, EZRS2 MOTORS MOBILUS MOTOR Spółka z o.o. ul. Miętowa 37, 61-680 Poznań, PL tel. +48 61 825 81 11, fax +48 61 825 80 52 VAT NO. PL9721078008
More informationSI-102. PIR Motion Sensor. User Manual
SI-102 PIR Motion Sensor User Manual Copyright and Disclaimer Copyright & Disclaimer No part of this publication may be reproduced in any form or by any means, whether electronic, mechanical, photocopying,
More informationUser Manual. Smart Lock. Please read this manual before operating your Smart Lock, and keep it for further reference. 40
User Manual Smart Lock Please read this manual before operating your Smart Lock, and keep it for further reference. 40 I. Introduction Thank you for choosing the AKASO Smart Lock. The new Smart Lock uses
More information