1 Pre-computed backprojection based penalized-likelihood (PPL) reconstruction with an edge-preserved regularizer for stationary Digital Breast Tomosynthesis Shiyu Xu a, Christy Redmon Inscoe b, Jianping Lu b,c, Otto Zhou b,c, Ying Chen a,* a Department of Electrical and Computer Engineering, Southern Illinois University Carbondale, IL USA; b Department of Physics and Astronomy and Curriculum in Applied Sciences and Engineering, University of North Carolina Chapel Hill, NC USA; c Lineberger Comprehensive Cancer Center, University of North Carolina Chapel Hill, NC USA; * Corresponding author ABSTRACT Stationary Digital Breast Tomosynthesis (sdbt) is a carbon nanotube based breast imaging device with fast data acquisition and decent projection resolution to provide three dimensional (3-D) volume information. Tomosynthesis 3-D image reconstruction is faced with the challenges of the cone beam geometry and the incomplete and nonsymmetric sampling due to the sparse views and limited view angle. Among all available reconstruction methods, statistical iterative method exhibits particular promising since it relies on an accurate physical and statistical model with prior knowledge. In this paper, we present the application of an edge-preserved regularizer to our previously proposed precomputed backprojection based penalized-likelihood (PPL) reconstruction. By using the edge-preserved regularizer, our experiments show that through tuning several parameters, resolution can be retained while noise is reduced significantly. Compared to other conventional noise reduction techniques in image reconstruction, less resolution is lost in order to gain certain noise reduction, which may benefit the research of low dose tomosynthesis. Keywords: edge-preserved regularization, non-quadratic penalty, stationary digital breast tomosynthesis, statistical iterative reconstruction, noise reduction. 1. INTRODUCTION Digital Breast Tomosysthesis (DBT) 1,2 draws a lot of attentions in clinical applications to improve early breast cancer detection by providing three dimensional (3D) anatomical imaging. Currently most DBT systems are built upon the regular full-field digital mammography (FFDM) systems and require partial isocentric motion of an X-ray tube over certain angular range to acquire multiple projection data. This prolongs the scanning time and degrades the imaging quality. To reduce the limitations above, a stationary DBT (s-dbt) scanner has been developed based on the spatially distributed multi-beam field emission X-ray (MBFEX) source technique with the carbon nanotube (CNT). 3,4 In Tomosynthesis, 3D image reconstruction is faced with challenges of the cone beam geometry and the incomplete and nonsymmetric sampling due to sparse views and limited view angle. These challenges lead to reduced image quality in clinical applications, such as high noise and serious out-of-plane artifacts. Among all available reconstruction method, statistical iterative reconstruction 5 exhibits particularly promising since it provides the flexibility of accurate physical noise modeling and geometric system description. In our previous study, we proposed pre-computed backprojection based penalized-likelihood (PPL) reconstruction with a quadratic penalty, 6 8 which provides predictable image quality based on a pre-computed look-up table. However, a quadratic penalty has a uniform influence on entire voxels, which may lead to a over-smoothening on edges. The purpose of this paper is to introduce a non-quadratic regularizer to set up a more flexible framework to balance the edge-preservation and noise reduction. The parameter choice of the regularizer is also investigated to gain better image quality based on phantom studies with sdbt system V. 1 (p.1 of 6) / Color: No / Format: Letter / Date: 1/22/ :33:22 AM

2 2. METHODS AND MATERIALS In the model of X-ray imaging, the poisson distribution of incident photon number dominates the physical process. Although X-ray detectors are not quanta counters, the signal statistics of mono-energetic X-ray detection 9 is still considered to be a poisson distribution. The probability of photon number detected along the i-th X-ray is described mathematically as i e θi P(Y i = y i ) = θyi y i!, (1) wherey i isarandomvariablecountingtheobservedphotonsonthedetectoralongi-thx-ray; y i istheobservation of Y i ; θ i is the expectation value of the random variable Y i. θ i can be expressed as θ i = d i e <µ,li>, (2) where d i is the intensity of the incident X-ray beam; µ is a linear attenuation coefficient vector to be estimated. l i denotes the vector of the intersection length of the i-th X-ray within voxels. The negative log-likelihood function of all observed photons on the detector can be written as 10 L(µ) = where M is the number of X-ray beams; c is a constant. M {d i e <µ,li> +y i < µ,l i >}+c, (3) i By applying a λ-scaled regularizer R to penalize the likelihood function, the noise induced by X-ray scattering and electronic noise can be mitigated. The log penalized-likelihood function can be written as Φ(µ) = L(µ)+λR(µ) (4) Previously we introduced a modified quadratic regularizer 6,7 into Tomosynthesis statistical reconstruction to quantify the effect of λ on resolution properties, 11 which is R m (µ) = N j=1 κ 2 j k N j (µ j µ k ) 2, (5) where N is the total number of voxels; N j denotes the index subset of the neighbour voxels of the j-th voxel. κ can be computed by a backprojection equivalent operation, which is κ 2 i=1 j = l2 ij y i. (6) i=1 l2 ij κ absorbs the data-dependency term in resolution properties. Thereby a uniform resolution can be achieved within the reconstructed volume. A quadratic penalty has a uniform influence on universal voxels, which may lead to a over-smoothed edge. The generalized Gaussian Markov random field (GGMRF) as a edge-preserved prior was introduced in literature. 12 A more flexible q-generalized Gaussian MRF (q-ggmrf) was applied in model based iterative reconstruction (MBIR) 13 which offers the potential of combined noise reduction, high spatial resolution, contrast enhancement and artifact reduction for low-dose imaging or enhanced image clarity for improved diagnostic confidence. In our Tomosynthesis application, we use the simpler GGMRF to gain these benefits, which has the form as follows where R m (µ) = N j=1 κ 2 j k N j ρ(µ j µ k ), (7) ρ( ) = c p. (8) V. 1 (p.2 of 6) / Color: No / Format: Letter / Date: 1/22/ :33:22 AM

3 Figure 1. Influence function of the GGMRF regularizer with different parameters. The corresponding derivative is known as the influence function ρ ( ) = p p 1 c p sign( ). (9) The exponent parameter p of the GGMRF allows one to control the degree of edge preservation in the reconstruction. As long as p > 1, the resulting regularizer term is strictly convex. The constant c determines the approximate threshold of transition between low and high contrast regions. When p = 2 and c = 1 the regularizer term is quadratic and the reconstructed images tend to produce a softer edge. As p is reduced, the regularizer becomes non-quadratic and edge sharpness tends to be preserved. In Fig. 1, we compares the influence function of the quadratic regularizer to several edge-preserving GGMRF priors. In the quadratic cases (p = 2), the influence functions are linear around the origin, which controls textures in a uniform manner. Reduced p retains better edge-preserving characteristics, as influence function tends to be constant for larger difference of voxel. The value c controls the inflexion point. Higher c pushes the edge preserving behaviour towards the origin. For example, to maintain the influence as the same as the quadratic below the difference value of 0.01, which is considered as the upper boundary of noise level, the c p values for the cases p = 1.8,p = 1.7,p = 1.61 are set as 2.5,3.5,5.3. With the choice of the strictly convex regularizer, the objective function defined in Eq. 4 has a unique global minimum. To estimate voxels at the unique global optimal, both ICD 14 and relaxed OS-SPS 15 can provide fast algorithms. The former produces a faster convergence on high frequency voxel with a sequential voxel update and the latter provides a parallel computation with a decent convergence rate. We choose relax OS-SPS in our application for a more flexible parallel computing framework. By applying the idea of optimization transfer 16 on GGMRF regularizer, The iterative solution is derived as follows. µ (n+1) j = µ (n) j i=1 l ij( d i e <µ(n),l i> +y i )+λκ 2 j k N j p µ (n) j µ (n) i=1 (l ij sign( ). (10) N j=1 l ijd i e <µ(n),l i> )+2p(p 1)λκ 2 µ j k N (n) µ (n) j k p 2 j c p k p 1 c p In the implementation, voxels are able to be processed simultaneously due to the mutual independence update. One forward projection and one backward projection are required in one iteration. Ray-driven method is employed in forward model. In addition, κ is pre-calculated with a backprojection-equivalent computation prior to all iterations. To study the effects of our proposed regularizer on image quality, we investigate the regularizer with p = 1.8,c p = 2 and p = 1.8,c p = 2.5, and then compare them to our previous OS-PPL with a quadratic penalty, 6 8 which is a special case of the GGMRF with p = 2,c = 1. Other representative methods such as filtered V. 1 (p.3 of 6) / Color: No / Format: Letter / Date: 1/22/ :33:22 AM

4 Figure 2. Reconstructed mass between our proposed methods with various parameter choices and some representative methods. From left to right, ROIs are reconstructed by OSEM, OS-PPL(p = 1.8, c p = 2), OS-PPL(p = 1.8, c p = 2.5), OS-PPL(p = 2, c = 1), FBP Figure 3. Reconstructed micro-calcification between our proposed methods with various parameter choices and some representative methods. From left to right, ROIs are reconstructed by OSEM, OS-PPL(p = 1.8, c p = 2), OS-PPL(p = 1.8, c p = 2.5), OS-PPL(p = 2, c = 1), FBP backprojection (FBP) and ordered subsets maximum likelihood expectation minimization (OSEM) are presented aswell. λinos-pplispresetas8accordingtoourpreviousstudy. 6 Toguaranteeglobalconvergence, alliterative methods are initialized by three-time iterations of OS method and followed by a non-os method for ten-time iterations. The data was collected with the sdbt prototype system. 3,4 Scatter correction technique 17 is applied with the data to improve the high and low contrast. The origin of the 3-D coordinate system is located at the center of the detector. A flat panel detector is used for image acquisition. With a 140µm pixel pitch, the total image size is 2048x1661. The multiple X-ray beams are positioned along a straight line parallel to the detector plane. The source is designed to have 15 X-ray beams spanning a distance of 32.38cm from end to end. The linear spacing between the X-ray beams varies to provide an even 2 o angular spacing. A 3-D breast phantom is placed on a stage with a 2.54 cm air gap. The images were acquired using: 28KVp, molybdenum filter, molybdenum target and 20mAs per projections. 3. RESULTS Fig. 2 and Fig. 3 present mass and micro-calcifications equivalent objects in respective focus plane reconstructed by OS-PPL with our proposed regularizer and other representative algorithms. In Fig. 2, one can see that statistical iterative methods provide better artifacts suppression around objects than FBP. In addition, the OS-PPL with p = 1.8,c p = 2 presents best noise reduction among all investigated methods. In Fig. 3, the microcalcifications can be clearly seen with statistical iterative methods, while FBP yields a little blurred sharpness along horizontal direction. Point spread function (PSF) curves in Fig. 4 are measured by crossing the isolated micro-calcification in Fig. 3. These PSF curves are then fitted into the Gaussian functions to remove the noise. The Fourier transform of the fitted Gaussian function is the MTF. The resolution frequency at 50% MTF peak value was used as the quantitative measure of the in-plane image resolution. As shown in Fig. 5, OSEM and OS-PPL with p = 1.8, c = 2.5 provide more precise resolution than other methods. The resolution produced by quadratic OS-PPL is similar to FBP. Contrast to noise ratio is used to present the capability of low contrast detection. In our experiments, CNR are evaluated by subtracting the mean value in the background from the mean value in the mass shown in Fig. 2 and dividing the standard deviation in the background. The half width of 50% MTF, standard deviation and CNR are summarized in Tab V. 1 (p.4 of 6) / Color: No / Format: Letter / Date: 1/22/ :33:22 AM

5 PSF fbp os ppl p2c1 os ppl p1.8c2 os ppl p1.8c2.5 osem MTF fbp os ppl p2c1 os ppl p1.8c2 os ppl p1.8c2.5 osem Figure 4. Comparison of PSFs reconstructed by FBP, SART, OSEM and PPL Figure 5. Comparison of ASFs reconstructed by SART, OSEM and PPL Table 1. Noise, CNR and in-plane MTF for OS-PPL with the proposed regularizers and other representative reconstruction methods Recon. method parameters Std. Dev CNR HWHM of MTF (cycle/mm) OSEM n/a OS-PPL p = 1.8, c p = OS-PPL p = 1.8, c p = OS-PPL p = 2, c = FBP n/a According to Tab. 1, OSEM provides the best resolution but a little lower CNR. OS-PPL with p = 1.8,c = 2 presents a superior CNR among all which is almost improved by 5-fold compared to FBP. However, the regularizer with p = 1.8,c = 2 tends to soften the sharpness of micro-calcification. Overall, the regularizer with p = 1.8,c = 2.5 produces a comparable resolution to OSEM and a decent CNR which is 1.5 times better than OSEM and 2.5 times better than FBP. 4. CONCLUSION Statistical iterative reconstruction exhibits particular promising since it provides the flexibility of accurate physical noise modeling and geometric system description in transmission imaging system. In our previous study, OS-PPL reconstruction with a quadratic penalty was proposed to provide predictable image quality of reconstructed results, where the tradeoff between resolution and noise can be controlled by adjusting the scaler λ based on a pre-computed look-up table. In this study, to reduce the noise without significant resolution loss, an edge-preserved regularizer was proposed to our OS-PPL method with a sdbt system. Two extra parameters are introduced to make tuning image quality more flexible and achievable. Influence function is presented to visualize the effect of these parameters on resolution. Experiment results show that by the proposed regularizer, resolution can be retained as much as possible while noise is reduced by tuning the parameter p and c. This benefit may allow to reduce the X-ray dose while maintaining a comparable image quality. Further experiments are needed to seek an optimal parameter combination. In addition, dose reduction experiments will be conducted with the inspiration of the edge-preserved iterative technique. ACKNOWLEDGMENTS This work is supported by grant NIH/NCI R01 CA A1. Shiyu Xu wants to thank Dr. Henri Schurz in mathematics department at SIUC due to the meaningful discussions and thank Dr. Shaikh Ahmed in ECE department at SIUC for the computation resources V. 1 (p.5 of 6) / Color: No / Format: Letter / Date: 1/22/ :33:22 AM

6 REFERENCES [1] Dobbins, J. T. and Godfrey, D. J., Digital X-ray tomosynthesis: current state of the art and clinical potential, Phys. Med. Biol. 48(19), (2003). [2] Chen, Y., Digital Breast Tomosynthesis (DBT) - a novel imaging technology to improve early breast cancer detection: implementation, comparison and optimization, PhD thesis, Department of Electrical Computer Engineering, Duke University (2007). [3] Qian, X., Rajaram, R., Calderon-Colon, X., Yang, G., Phan, T., Lu, D. S. L. J., and Zhou, O., Design and characterization of a spatially distributed multibeam field emission x-ray source for stationary digital breast tomosynthesis, Medical Physics 36, (2009). [4] Tucker, A. W., Lu, J., and Zhou, O., Dependency of image quality on system configuration parameters in a stationary dgital breast tomosynthesis system, Medical Physics 40(3), (2013). [5] Fessler, J. A., Iterative method for image reconstruction, tech. rep., EECS Department, Univ. of Michigan. Ann Arbor (2006). [6] Xu, S., Chen, Y., Lu, J., and Zhou, O., An application of pre-computed backprojection based penalizedlikelihood image reconstruction on stationary digital breast tomosynthesis, Proc. SPIE 8668, 86680v (2013). [7] Xu, S. and Chen, Y., An simulation based image reconstruction strategy with predictable image quality in limited-angle X-ray, Proc. SPIE 8668, 86685p (2013). [8] Xu, S., Schurz, H., and Chen, Y., Parameter optimization of relaxed ordered subsets pre-computed back projection (BP) based penalized-likelihood (OS-PPL) reconstruction in limited-angle X-ray tomography, Computerized Medical Imaging and Graphics 37(4), (2013). [9] Elbakri, I. A. and Fessler, J. A., Efficient and accurate likelihood for iterative image reconstruction in X-ray computed tomography, Proceedings of SPIE 5(3), (1996). [10] Lange, K. and Fessler, J. A., Globally convergent algorithms for maximum a posteriori transmission tomography, IEEE Transactions on Image Processing 4(10), (1995). [11] Stayman, J. W. and Fessler, J. A., Regularization for uniform spatial resolution properties in penalizedlikelihood image reconstruction, IEEE Transactions on Medical Imaging 19, (2000). [12] Bouman, C. A. and Sauer, K., A generalized guassian image model for edge-preserving map estimation, IEEE Transactions on image processing 2, (1993). [13] Thibault, J.-B., Sauer, K. D., Bouman, C. A., and Hsien, J., A three-dimensional statistical approach to improved image quality for multislice helical CT, Med. Phys 34(11), (2007). [14] Yu, Z., Thibault, J.-B., Bouman, C. A., Sauer, K. D., and Hsien, J., Fast model-based x-ray CT reconstruction using spatially non-homogeneous icd optimization, IEEE Transactions on image processing 20(1), (2011). [15] Ahn, S. and Fessler, J. A., Globally convergent image reconstruction for emission tomography using relaxed ordered subsets algorithm, IEEE Transactions on Medical Imaging 22, (2003). [16] Erdogan, H. and Fessler, J. A., Monotonic algorithms for transmission tomography, IEEE Transactions on Medical Imaging 18, (1999). [17] Inscoe, C. R., Tucker, A. W., Lu, J., and Zhou, O. Z., Demonstration of a scatter correction technique in digital breast tomosynthesis, Proc. SPIE 8668, 86680H (2013) V. 1 (p.6 of 6) / Color: No / Format: Letter / Date: 1/22/ :33:22 AM

Statistical iterative reconstruction using fast optimization transfer algorithm with successively increasing factor in Digital Breast Tomosynthesis

Statistical iterative reconstruction using fast optimization transfer algorithm with successively increasing factor in Digital Breast Tomosynthesis Statistical iterative reconstruction using fast optimization transfer algorithm with successively increasing factor in Digital Breast omosynthesis Shiyu Xu a and Zhenxi Zhang b and Ying Chen a,* a Department

More information

Shiyu Xu a, Henri Schurz b, Ying Chen a,c, Abstract

Shiyu Xu a, Henri Schurz b, Ying Chen a,c, Abstract Parameter Optimization of relaxed Ordered Subsets Pre-computed Back Projection (BP) based Penalized-Likelihood (OS-PPL) Reconstruction in Limited-angle X-ray Tomography Shiyu Xu a, Henri Schurz b, Ying

More information

Noise power spectrum and modulation transfer function analysis of breast tomosynthesis imaging

Noise power spectrum and modulation transfer function analysis of breast tomosynthesis imaging Noise power spectrum and modulation transfer function analysis of breast tomosynthesis imaging Weihua Zhou a, Linlin Cong b, Xin Qian c, Yueh Z. Lee d, Jianping Lu c,e, Otto Zhou c,e, *Ying Chen a,b a

More information

Breast tomosynthesis reconstruction with a multi-beam x-ray source

Breast tomosynthesis reconstruction with a multi-beam x-ray source Breast tomosynthesis reconstruction with a multi-beam x-ray source Ying Chen *a,b, Weihua Zhou a, Guang Yang c, Xin Qian c, Jianping Lu c,d, and Otto Zhou a Dept. of Electrical and Computer Engineering,

More information

Acknowledgments and financial disclosure

Acknowledgments and financial disclosure AAPM 2012 Annual Meeting Digital breast tomosynthesis: basic understanding of physics principles James T. Dobbins III, Ph.D., FAAPM Director, Medical Physics Graduate Program Ravin Advanced Imaging Laboratories

More information

An Efficient Technique For Multi-Phase Model Based Iterative Reconstruction

An Efficient Technique For Multi-Phase Model Based Iterative Reconstruction 1 An Efficient Technique For Multi-Phase Model Based Iterative Reconstruction Shiyu Xu, Debashish Pal and Jean-Baptiste Thibault Abstract Multi-phase scan is a fundamental CT acquisition technology used

More information

F3-A5: Toward Model-Based Reconstruction in Scanned Baggage Security Applications

F3-A5: Toward Model-Based Reconstruction in Scanned Baggage Security Applications F3-A5: Toward Model-Based Reconstruction in Scanned Baggage Security Applications Abstract While traditional direct reconstruction algorithms such as filtered back projection depend on the analytic inversion

More information

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004

Spiral ASSR Std p = 1.0. Spiral EPBP Std. 256 slices (0/300) Kachelrieß et al., Med. Phys. 31(6): , 2004 Spiral ASSR Std p = 1.0 Spiral EPBP Std p = 1.0 Kachelrieß et al., Med. Phys. 31(6): 1623-1641, 2004 256 slices (0/300) Advantages of Cone-Beam Spiral CT Image quality nearly independent of pitch Increase

More information

A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis

A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis A comparative study of limited-angle cone-beam reconstruction methods for breast tomosynthesis Yiheng Zhang, a Heang-Ping Chan, Berkman Sahiner, Jun Wei, Mitchell M. Goodsitt, Lubomir M. Hadjiiski, Jun

More information

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images

Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images Simulation of Mammograms & Tomosynthesis imaging with Cone Beam Breast CT images Tao Han, Chris C. Shaw, Lingyun Chen, Chao-jen Lai, Xinming Liu, Tianpeng Wang Digital Imaging Research Laboratory (DIRL),

More information

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION

CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION CT NOISE POWER SPECTRUM FOR FILTERED BACKPROJECTION AND ITERATIVE RECONSTRUCTION Frank Dong, PhD, DABR Diagnostic Physicist, Imaging Institute Cleveland Clinic Foundation and Associate Professor of Radiology

More information

Evaluation of Back Projection Methods for Breast Tomosynthesis Image Reconstruction

Evaluation of Back Projection Methods for Breast Tomosynthesis Image Reconstruction DOI 10.1007/s10278-014-9736-6 Evaluation of Back Projection Methods for Breast Tomosynthesis Image Reconstruction Weihua Zhou & Jianping Lu & Otto Zhou & Ying Chen # Society for Imaging Informatics in

More information

Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction

Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction Generalized Filtered Backprojection for Digital Breast Tomosynthesis Reconstruction Klaus Erhard a, Michael Grass a, Sebastian Hitziger b, Armin Iske b and Tim Nielsen a a Philips Research Europe Hamburg,

More information

F3-A5: Model-Based Iterative Reconstruction for Advanced Baggage Screening

F3-A5: Model-Based Iterative Reconstruction for Advanced Baggage Screening F3-A5: Model-Based Iterative Reconstruction for Advanced Baggage Screening Abstract While traditional direct reconstruction algorithms such as filtered back projection (FBP) and direct Fourier method (DFM)

More information

Axial block coordinate descent (ABCD) algorithm for X-ray CT image reconstruction

Axial block coordinate descent (ABCD) algorithm for X-ray CT image reconstruction Axial block coordinate descent (ABCD) algorithm for X-ray CT image reconstruction Jeffrey A. Fessler and Donghwan Kim EECS Department University of Michigan Fully 3D Image Reconstruction Conference July

More information

Limited View Angle Iterative CT Reconstruction

Limited View Angle Iterative CT Reconstruction Limited View Angle Iterative CT Reconstruction Sherman J. Kisner a, Eri Haneda a, Charles A. Bouman a, Sondre Skatter b, Mikhail Kourinny b, and Simon Bedford c a Purdue University, West Lafayette, IN,

More information

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration

Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Low-Dose Dual-Energy CT for PET Attenuation Correction with Statistical Sinogram Restoration Joonki Noh, Jeffrey A. Fessler EECS Department, The University of Michigan Paul E. Kinahan Radiology Department,

More information

Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT. y i Poisson I i (E)e R } where, b i

Simplified statistical image reconstruction algorithm for polyenergetic X-ray CT. y i Poisson I i (E)e R } where, b i implified statistical image reconstruction algorithm for polyenergetic X-ray C omesh rivastava, tudent member, IEEE, and Jeffrey A. Fessler, enior member, IEEE Abstract In X-ray computed tomography (C),

More information

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE / Radiographic Tomosynthesis: Image Quality and Artifacts Reduction Baojun Li, Ph.D Department of Radiology Boston University Medical Center 2012 AAPM Annual Meeting Background Linear Trajectory Tomosynthesis

More information

Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system

Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system Implementation and evaluation of a fully 3D OS-MLEM reconstruction algorithm accounting for the PSF of the PET imaging system 3 rd October 2008 11 th Topical Seminar on Innovative Particle and Radiation

More information

Spatial Resolution Properties in Penalized-Likelihood Reconstruction of Blurred Tomographic Data

Spatial Resolution Properties in Penalized-Likelihood Reconstruction of Blurred Tomographic Data Spatial Resolution Properties in Penalized-Likelihood Reconstruction of Blurred Tomographic Data Wenying Wang, Grace J. Gang and J. Webster Stayman Department of Biomedical Engineering, Johns Hopkins University,

More information

A Projection Access Scheme for Iterative Reconstruction Based on the Golden Section

A Projection Access Scheme for Iterative Reconstruction Based on the Golden Section A Projection Access Scheme for Iterative Reconstruction Based on the Golden Section Thomas Köhler Philips Research Laboratories Roentgenstrasse - Hamburg Germany Abstract A new access scheme for projections

More information

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT

Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT Evaluation of Spectrum Mismatching using Spectrum Binning Approach for Statistical Polychromatic Reconstruction in CT Qiao Yang 1,4, Meng Wu 2, Andreas Maier 1,3,4, Joachim Hornegger 1,3,4, Rebecca Fahrig

More information

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH

3/27/2012 WHY SPECT / CT? SPECT / CT Basic Principles. Advantages of SPECT. Advantages of CT. Dr John C. Dickson, Principal Physicist UCLH 3/27/212 Advantages of SPECT SPECT / CT Basic Principles Dr John C. Dickson, Principal Physicist UCLH Institute of Nuclear Medicine, University College London Hospitals and University College London john.dickson@uclh.nhs.uk

More information

Splitting-Based Statistical X-Ray CT Image Reconstruction with Blind Gain Correction

Splitting-Based Statistical X-Ray CT Image Reconstruction with Blind Gain Correction Splitting-Based Statistical X-Ray CT Image Reconstruction with Blind Gain Correction Hung Nien and Jeffrey A. Fessler Department of Electrical Engineering and Computer Science University of Michigan, Ann

More information

A Weighted Least Squares PET Image Reconstruction Method Using Iterative Coordinate Descent Algorithms

A Weighted Least Squares PET Image Reconstruction Method Using Iterative Coordinate Descent Algorithms A Weighted Least Squares PET Image Reconstruction Method Using Iterative Coordinate Descent Algorithms Hongqing Zhu, Huazhong Shu, Jian Zhou and Limin Luo Department of Biological Science and Medical Engineering,

More information

FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION

FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION 2009 IEEE Nuclear Science Symposium Conference Record M03-7 FAST KVP-SWITCHING DUAL ENERGY CT FOR PET ATTENUATION CORRECTION Wonseok Huh, Jeffrey A. Fessler, Adam M. Alessio, and Paul E. Kinahan Department

More information

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT

Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT Projection and Reconstruction-Based Noise Filtering Methods in Cone Beam CT Benedikt Lorch 1, Martin Berger 1,2, Joachim Hornegger 1,2, Andreas Maier 1,2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg

More information

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA

Computed Tomography. Principles, Design, Artifacts, and Recent Advances. Jiang Hsieh THIRD EDITION. SPIE PRESS Bellingham, Washington USA Computed Tomography Principles, Design, Artifacts, and Recent Advances THIRD EDITION Jiang Hsieh SPIE PRESS Bellingham, Washington USA Table of Contents Preface Nomenclature and Abbreviations xi xv 1 Introduction

More information

Estimating 3D Respiratory Motion from Orbiting Views

Estimating 3D Respiratory Motion from Orbiting Views Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct. 2005 Funding provided by NIH Grant P01 CA59827 Motivation Free-breathing

More information

Limited View Angle Iterative CT Reconstruction

Limited View Angle Iterative CT Reconstruction Limited View Angle Iterative CT Reconstruction Sherman J. Kisner 1, Eri Haneda 1, Charles A. Bouman 1, Sondre Skatter 2, Mikhail Kourinny 2, Simon Bedford 3 1 Purdue University, West Lafayette, IN, USA

More information

Background 8/2/2011. Development of Breast Models for Use in Simulation of Breast Tomosynthesis and CT Breast Imaging. Stephen J.

Background 8/2/2011. Development of Breast Models for Use in Simulation of Breast Tomosynthesis and CT Breast Imaging. Stephen J. Development of Breast Models for Use in Simulation of Breast Tomosynthesis and CT Breast Imaging Stephen J. Glick* J. Michael O Connor**, Clay Didier**, Mini Das*, * University of Massachusetts Medical

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

Translational Computed Tomography: A New Data Acquisition Scheme

Translational Computed Tomography: A New Data Acquisition Scheme 2nd International Symposium on NDT in Aerospace 2010 - We.1.A.3 Translational Computed Tomography: A New Data Acquisition Scheme Theobald FUCHS 1, Tobias SCHÖN 2, Randolf HANKE 3 1 Fraunhofer Development

More information

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago

Optimization of CT Simulation Imaging. Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT Simulation Imaging Ingrid Reiser Dept. of Radiology The University of Chicago Optimization of CT imaging Goal: Achieve image quality that allows to perform the task at hand (diagnostic

More information

Optimal threshold selection for tomogram segmentation by reprojection of the reconstructed image

Optimal threshold selection for tomogram segmentation by reprojection of the reconstructed image Optimal threshold selection for tomogram segmentation by reprojection of the reconstructed image K.J. Batenburg 1 and J. Sijbers 1 University of Antwerp, Vision Lab, Universiteitsplein 1, B-2610 Wilrijk,

More information

DUAL energy X-ray radiography [1] can be used to separate

DUAL energy X-ray radiography [1] can be used to separate IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 53, NO. 1, FEBRUARY 2006 133 A Scatter Correction Using Thickness Iteration in Dual-Energy Radiography S. K. Ahn, G. Cho, and H. Jeon Abstract In dual-energy

More information

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT.

1. Deployment of a framework for drawing a correspondence between simple figure of merits (FOM) and quantitative imaging performance in CT. Progress report: Development of assessment and predictive metrics for quantitative imaging in chest CT Subaward No: HHSN6801000050C (4a) PI: Ehsan Samei Reporting Period: month 1-18 Deliverables: 1. Deployment

More information

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection Caroline Vienne 1, Marius Costin 1 More info about this article: http://www.ndt.net/?id=21917 1 CEA, LIST, Département

More information

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D.

Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Multi-slice CT Image Reconstruction Jiang Hsieh, Ph.D. Applied Science Laboratory, GE Healthcare Technologies 1 Image Generation Reconstruction of images from projections. textbook reconstruction advanced

More information

Improvement of Efficiency and Flexibility in Multi-slice Helical CT

Improvement of Efficiency and Flexibility in Multi-slice Helical CT J. Shanghai Jiaotong Univ. (Sci.), 2008, 13(4): 408 412 DOI: 10.1007/s12204-008-0408-x Improvement of Efficiency and Flexibility in Multi-slice Helical CT SUN Wen-wu 1 ( ), CHEN Si-ping 2 ( ), ZHUANG Tian-ge

More information

Quality control phantoms and protocol for a tomography system

Quality control phantoms and protocol for a tomography system Quality control phantoms and protocol for a tomography system Lucía Franco 1 1 CT AIMEN, C/Relva 27A O Porriño Pontevedra, Spain, lfranco@aimen.es Abstract Tomography systems for non-destructive testing

More information

Acknowledgments. High Performance Cone-Beam CT of Acute Traumatic Brain Injury

Acknowledgments. High Performance Cone-Beam CT of Acute Traumatic Brain Injury A. Sisniega et al. (presented at RSNA 214) High Performance Cone-Beam CT of Acute Traumatic Brain Injury A. Sisniega 1 W. Zbijewski 1, H. Dang 1, J. Xu 1 J. W. Stayman 1, J. Yorkston 2, N. Aygun 3 V. Koliatsos

More information

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT

Beam Attenuation Grid Based Scatter Correction Algorithm for. Cone Beam Volume CT 11th European Conference on Non-Destructive Testing (ECNDT 2014), October 6-10, 2014, Prague, Czech Republic Beam Attenuation Grid Based Scatter Correction Algorithm for More Info at Open Access Database

More information

Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET

Workshop on Quantitative SPECT and PET Brain Studies January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET Workshop on Quantitative SPECT and PET Brain Studies 14-16 January, 2013 PUCRS, Porto Alegre, Brasil Corrections in SPECT and PET Físico João Alfredo Borges, Me. Corrections in SPECT and PET SPECT and

More information

Penalized-Likelihood Reconstruction for Sparse Data Acquisitions with Unregistered Prior Images and Compressed Sensing Penalties

Penalized-Likelihood Reconstruction for Sparse Data Acquisitions with Unregistered Prior Images and Compressed Sensing Penalties Penalized-Likelihood Reconstruction for Sparse Data Acquisitions with Unregistered Prior Images and Compressed Sensing Penalties J. W. Stayman* a, W. Zbijewski a, Y. Otake b, A. Uneri b, S. Schafer a,

More information

GPU implementation for rapid iterative image reconstruction algorithm

GPU implementation for rapid iterative image reconstruction algorithm GPU implementation for rapid iterative image reconstruction algorithm and its applications in nuclear medicine Jakub Pietrzak Krzysztof Kacperski Department of Medical Physics, Maria Skłodowska-Curie Memorial

More information

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA

Spiral CT. Protocol Optimization & Quality Assurance. Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Ge Wang, Ph.D. Department of Radiology University of Iowa Iowa City, Iowa 52242, USA Spiral CT Protocol Optimization & Quality Assurance Protocol optimization

More information

DUE to beam polychromacity in CT and the energy dependence

DUE to beam polychromacity in CT and the energy dependence 1 Empirical Water Precorrection for Cone-Beam Computed Tomography Katia Sourbelle, Marc Kachelrieß, Member, IEEE, and Willi A. Kalender Abstract We propose an algorithm to correct for the cupping artifact

More information

Acknowledgments. Nesterov s Method for Accelerated Penalized-Likelihood Statistical Reconstruction for C-arm Cone-Beam CT.

Acknowledgments. Nesterov s Method for Accelerated Penalized-Likelihood Statistical Reconstruction for C-arm Cone-Beam CT. June 5, Nesterov s Method for Accelerated Penalized-Likelihood Statistical Reconstruction for C-arm Cone-Beam CT Adam S. Wang, J. Webster Stayman, Yoshito Otake, Gerhard Kleinszig, Sebastian Vogt, Jeffrey

More information

STATISTICAL image reconstruction methods for X-ray

STATISTICAL image reconstruction methods for X-ray IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 28, NO. 5, MAY 2009 645 Quadratic Regularization Design for 2-D CT Hugo R. Shi*, Student Member, IEEE, and Jeffrey A. Fessler, Fellow, IEEE Abstract Statistical

More information

Investigating Oblique Reconstructions with Super-Resolution in Digital Breast Tomosynthesis

Investigating Oblique Reconstructions with Super-Resolution in Digital Breast Tomosynthesis Investigating Oblique Reconstructions with Super-Resolution in Digital Breast Tomosynthesis Raymond J. Acciavatti, Stewart B. Mein, and Andrew D.A. Maidment University of Pennsylvania, Department of Radiology,

More information

COMPARATIVE STUDIES OF DIFFERENT SYSTEM MODELS FOR ITERATIVE CT IMAGE RECONSTRUCTION

COMPARATIVE STUDIES OF DIFFERENT SYSTEM MODELS FOR ITERATIVE CT IMAGE RECONSTRUCTION COMPARATIVE STUDIES OF DIFFERENT SYSTEM MODELS FOR ITERATIVE CT IMAGE RECONSTRUCTION BY CHUANG MIAO A Thesis Submitted to the Graduate Faculty of WAKE FOREST UNIVERSITY GRADUATE SCHOOL OF ARTS AND SCIENCES

More information

Noise weighting with an exponent for transmission CT

Noise weighting with an exponent for transmission CT doi:10.1088/2057-1976/2/4/045004 RECEIVED 13 January 2016 REVISED 4 June 2016 ACCEPTED FOR PUBLICATION 21 June 2016 PUBLISHED 27 July 2016 PAPER Noise weighting with an exponent for transmission CT Gengsheng

More information

Q.Clear. Steve Ross, Ph.D.

Q.Clear. Steve Ross, Ph.D. Steve Ross, Ph.D. Accurate quantitation (SUV - Standardized Uptake Value) is becoming more important as clinicians seek to utilize PET imaging for more than just diagnosing and staging disease, but also

More information

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct

Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct Arion: a realistic projection simulator for optimizing laboratory and industrial micro-ct J. DHAENE* 1, E. PAUWELS 1, T. DE SCHRYVER 1, A. DE MUYNCK 1, M. DIERICK 1, L. VAN HOOREBEKE 1 1 UGCT Dept. Physics

More information

(RMSE). Reconstructions showed that modeling the incremental blur improved the resolution of the attenuation map and quantitative accuracy.

(RMSE). Reconstructions showed that modeling the incremental blur improved the resolution of the attenuation map and quantitative accuracy. Modeling the Distance-Dependent Blurring in Transmission Imaging in the Ordered-Subset Transmission (OSTR) Algorithm by Using an Unmatched Projector/Backprojector Pair B. Feng, Member, IEEE, M. A. King,

More information

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University

Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid. Yingxuan Chen. Graduate Program in Medical Physics Duke University Scatter Correction for Dual source Cone beam CT Using the Pre patient Grid by Yingxuan Chen Graduate Program in Medical Physics Duke University Date: Approved: Lei Ren, Supervisor Fang Fang Yin, Chair

More information

Fast Model-Based X-ray CT Reconstruction. Using Spatially Non-Homogeneous ICD Optimization

Fast Model-Based X-ray CT Reconstruction. Using Spatially Non-Homogeneous ICD Optimization Fast Model-Based X-ray CT Reconstruction 1 Using Spatially Non-Homogeneous ICD Optimization Zhou Yu, Member, IEEE, Jean-Baptiste Thibault, Member, IEEE, Charles A. Bouman, Fellow, IEEE, Ken D. Sauer, Member,

More information

Image reconstruction and imaging configuration optimization with a novel nanotechnology enabled breast tomosynthesis multi-beam X-ray system

Image reconstruction and imaging configuration optimization with a novel nanotechnology enabled breast tomosynthesis multi-beam X-ray system Southern Illinois University Carbondale OpenSIUC Dissertations Theses and Dissertations 8-1-2012 Image reconstruction and imaging configuration optimization with a novel nanotechnology enabled breast tomosynthesis

More information

Tomographic Reconstruction

Tomographic Reconstruction Tomographic Reconstruction 3D Image Processing Torsten Möller Reading Gonzales + Woods, Chapter 5.11 2 Overview Physics History Reconstruction basic idea Radon transform Fourier-Slice theorem (Parallel-beam)

More information

Design Considerations in Optimizing a Breast Tomosynthesis System

Design Considerations in Optimizing a Breast Tomosynthesis System Design Considerations in Optimizing a Breast Tomosynthesis System Andrew Smith, Ph.D., Vice President - Imaging Science, Hologic Introduction Breast tomosynthesis, also referred to as three-dimensional

More information

Assessment of 3D performance metrics. X-ray based Volumetric imaging systems: Fourier-based imaging metrics. The MTF in CT

Assessment of 3D performance metrics. X-ray based Volumetric imaging systems: Fourier-based imaging metrics. The MTF in CT Assessment of 3D performance metrics D and 3D Metrics of Performance Towards Quality Index: Volumetric imaging systems X-ray based Volumetric imaging systems: CBCT/CT Tomosynthesis Samuel Richard and Ehsan

More information

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer Centre Western General Hospital EDINBURGH EH4

More information

Portability of TV-Regularized Reconstruction Parameters to Varying Data Sets

Portability of TV-Regularized Reconstruction Parameters to Varying Data Sets Portability of TV-Regularized Reconstruction Parameters to Varying Data Sets Mario Amrehn 1, Andreas Maier 1,2, Frank Dennerlein 1, Joachim Hornegger 1,2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg

More information

Image Acquisition Systems

Image Acquisition Systems Image Acquisition Systems Goals and Terminology Conventional Radiography Axial Tomography Computer Axial Tomography (CAT) Magnetic Resonance Imaging (MRI) PET, SPECT Ultrasound Microscopy Imaging ITCS

More information

Advanced Image Reconstruction Methods for Photoacoustic Tomography

Advanced Image Reconstruction Methods for Photoacoustic Tomography Advanced Image Reconstruction Methods for Photoacoustic Tomography Mark A. Anastasio, Kun Wang, and Robert Schoonover Department of Biomedical Engineering Washington University in St. Louis 1 Outline Photoacoustic/thermoacoustic

More information

Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization

Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization 1 Reconstruction of CT Images from Sparse-View Polyenergetic Data Using Total Variation Minimization T. Humphries and A. Faridani Abstract Recent work in CT image reconstruction has seen increasing interest

More information

Unique Features of the GE Senoclaire Tomosynthesis System. Tyler Fisher, M.S., DABR Therapy Physics, Inc.

Unique Features of the GE Senoclaire Tomosynthesis System. Tyler Fisher, M.S., DABR Therapy Physics, Inc. Unique Features of the GE Senoclaire Tomosynthesis System Tyler Fisher, M.S., DABR Therapy Physics, Inc. Conflict of Interest Disclosure I have no conflicts to disclose. Learning Objectives Overview of

More information

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset

Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset Discrete Estimation of Data Completeness for 3D Scan Trajectories with Detector Offset Andreas Maier 1, Patrick Kugler 2, Günter Lauritsch 2, Joachim Hornegger 1 1 Pattern Recognition Lab and SAOT Erlangen,

More information

Image quality of microcalcifications in digital breast tomosynthesis: Effects of projection-view distributions

Image quality of microcalcifications in digital breast tomosynthesis: Effects of projection-view distributions Image quality of microcalcifications in digital breast tomosynthesis: Effects of projection-view distributions Yao Lu, a) Heang-Ping Chan, Jun Wei, Mitch Goodsitt, Paul L. Carson, and Lubomir Hadjiiski

More information

Non-Stationary CT Image Noise Spectrum Analysis

Non-Stationary CT Image Noise Spectrum Analysis Non-Stationary CT Image Noise Spectrum Analysis Michael Balda, Björn J. Heismann,, Joachim Hornegger Pattern Recognition Lab, Friedrich-Alexander-Universität Erlangen Siemens Healthcare, Erlangen michael.balda@informatik.uni-erlangen.de

More information

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation

Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation Convolution-Based Truncation Correction for C-Arm CT using Scattered Radiation Bastian Bier 1, Chris Schwemmer 1,2, Andreas Maier 1,3, Hannes G. Hofmann 1, Yan Xia 1, Joachim Hornegger 1,2, Tobias Struffert

More information

Temperature Distribution Measurement Based on ML-EM Method Using Enclosed Acoustic CT System

Temperature Distribution Measurement Based on ML-EM Method Using Enclosed Acoustic CT System Sensors & Transducers 2013 by IFSA http://www.sensorsportal.com Temperature Distribution Measurement Based on ML-EM Method Using Enclosed Acoustic CT System Shinji Ohyama, Masato Mukouyama Graduate School

More information

4/19/2016. Deborah Thames R.T. (R)(M)(QM) Theory & Technology and advancement in 3D imaging DBT

4/19/2016. Deborah Thames R.T. (R)(M)(QM) Theory & Technology and advancement in 3D imaging DBT Deborah Thames R.T. (R)(M)(QM) Theory & Technology and advancement in 3D imaging DBT 1 Three manufacturers approved for Tomo Hologic and GE, and Siemens Why 2D Digital Mammography 2D FFDM it appears to

More information

Iterative SPECT reconstruction with 3D detector response

Iterative SPECT reconstruction with 3D detector response Iterative SPECT reconstruction with 3D detector response Jeffrey A. Fessler and Anastasia Yendiki COMMUNICATIONS & SIGNAL PROCESSING LABORATORY Department of Electrical Engineering and Computer Science

More information

A Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images

A Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images A Radiometry Tolerant Method for Direct 3D/2D Registration of Computed Tomography Data to X-ray Images Transfer Function Independent Registration Boris Peter Selby 1, Georgios Sakas 2, Stefan Walter 1,

More information

The Near Future in Cardiac CT Image Reconstruction

The Near Future in Cardiac CT Image Reconstruction SCCT 2010 The Near Future in Cardiac CT Image Reconstruction Marc Kachelrieß Institute of Medical Physics (IMP) Friedrich-Alexander Alexander-University Erlangen-Nürnberg rnberg www.imp.uni-erlangen.de

More information

USING cone-beam geometry with pinhole collimation,

USING cone-beam geometry with pinhole collimation, IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 56, NO. 3, JUNE 2009 687 A Backprojection-Based Parameter Estimation Technique for Skew-Slit Collimation Jacob A. Piatt, Student Member, IEEE, and Gengsheng L.

More information

Total Variation and Tomographic Imaging from Projections

Total Variation and Tomographic Imaging from Projections Total Variation and Tomographic Imaging from Projections Per Christian Hansen & Jakob Heide Jørgensen Technical University of Denmark Joint work with Dr. Emil Sidky & Prof. Xiaochuan Pan Univ. of Chicago

More information

CHAPTER 6 DETECTION OF MASS USING NOVEL SEGMENTATION, GLCM AND NEURAL NETWORKS

CHAPTER 6 DETECTION OF MASS USING NOVEL SEGMENTATION, GLCM AND NEURAL NETWORKS 130 CHAPTER 6 DETECTION OF MASS USING NOVEL SEGMENTATION, GLCM AND NEURAL NETWORKS A mass is defined as a space-occupying lesion seen in more than one projection and it is described by its shapes and margin

More information

Towards full-body X-ray images

Towards full-body X-ray images Towards full-body X-ray images Christoph Luckner 1,2, Thomas Mertelmeier 2, Andreas Maier 1, Ludwig Ritschl 2 1 Pattern Recognition Lab, FAU Erlangen-Nuernberg 2 Siemens Healthcare GmbH, Forchheim christoph.luckner@fau.de

More information

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh et al. : Proceedings of the National Seminar & Exhibition on Non-Destructive Evaluation DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE Rajesh V Acharya, Umesh Kumar, Gursharan

More information

Adaptive Reconstruction Methods for Low-Dose Computed Tomography

Adaptive Reconstruction Methods for Low-Dose Computed Tomography Adaptive Reconstruction Methods for Low-Dose Computed Tomography Joseph Shtok Ph.D. supervisors: Prof. Michael Elad, Dr. Michael Zibulevsky. Technion IIT, Israel, 011 Ph.D. Talk, Apr. 01 Contents of this

More information

Reconstruction from Projections

Reconstruction from Projections Reconstruction from Projections M.C. Villa Uriol Computational Imaging Lab email: cruz.villa@upf.edu web: http://www.cilab.upf.edu Based on SPECT reconstruction Martin Šámal Charles University Prague,

More information

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit

8/2/2016. Measures the degradation/distortion of the acquired image (relative to an ideal image) using a quantitative figure-of-merit Ke Li Assistant Professor Department of Medical Physics and Department of Radiology School of Medicine and Public Health, University of Wisconsin-Madison This work is partially supported by an NIH Grant

More information

Improving Reconstructed Image Quality in a Limited-Angle Positron Emission

Improving Reconstructed Image Quality in a Limited-Angle Positron Emission Improving Reconstructed Image Quality in a Limited-Angle Positron Emission Tomography System David Fan-Chung Hsu Department of Electrical Engineering, Stanford University 350 Serra Mall, Stanford CA 94305

More information

Digital Scatter Removal in Mammography to enable Patient Dose Reduction

Digital Scatter Removal in Mammography to enable Patient Dose Reduction Digital Scatter Removal in Mammography to enable Patient Dose Reduction Mary Cocker Radiation Physics and Protection Oxford University Hospitals NHS Trust Chris Tromans, Mike Brady University of Oxford

More information

Feldkamp-type image reconstruction from equiangular data

Feldkamp-type image reconstruction from equiangular data Journal of X-Ray Science and Technology 9 (2001) 113 120 113 IOS Press Feldkamp-type image reconstruction from equiangular data Ben Wang a, Hong Liu b, Shiying Zhao c and Ge Wang d a Department of Elec.

More information

SPECT reconstruction

SPECT reconstruction Regional Training Workshop Advanced Image Processing of SPECT Studies Tygerberg Hospital, 19-23 April 2004 SPECT reconstruction Martin Šámal Charles University Prague, Czech Republic samal@cesnet.cz Tomography

More information

Scatter Correction Methods in Dimensional CT

Scatter Correction Methods in Dimensional CT Scatter Correction Methods in Dimensional CT Matthias Baer 1,2, Michael Hammer 3, Michael Knaup 1, Ingomar Schmidt 3, Ralf Christoph 3, Marc Kachelrieß 2 1 Institute of Medical Physics, Friedrich-Alexander-University

More information

AIDR 3D Iterative Reconstruction:

AIDR 3D Iterative Reconstruction: Iterative Reconstruction: Integrated, Automated and Adaptive Dose Reduction Erin Angel, PhD Manager, Clinical Sciences, CT Canon Medical Systems USA Iterative Reconstruction 1 Since the introduction of

More information

Energy resolved X-ray diffraction Cl. J.Kosanetzky, G.Harding, U.Neitzel

Energy resolved X-ray diffraction Cl. J.Kosanetzky, G.Harding, U.Neitzel Proc. Of SPIE Vol 0626, Application of Optical Instrumentation in Medicine XIV and Picture Archiving and Communication Systems(PACS IV) for Medical Applications IV, ed. S J Dwyer/R H Schneider (Jan 1986)

More information

Correlation between Model and Human Observer Performance on a Lesion Shape Discrimination Task in CT

Correlation between Model and Human Observer Performance on a Lesion Shape Discrimination Task in CT Correlation between Model and Human Observer Performance on a Lesion Shape Discrimination Task in CT Yi Zhang, Shuai Leng, Lifeng Yu and Cynthia McCollough Department of Radiology Mayo Clinic, Rochester

More information

Digital Image Processing

Digital Image Processing Digital Image Processing SPECIAL TOPICS CT IMAGES Hamid R. Rabiee Fall 2015 What is an image? 2 Are images only about visual concepts? We ve already seen that there are other kinds of image. In this lecture

More information

Adaptive algebraic reconstruction technique

Adaptive algebraic reconstruction technique Adaptive algebraic reconstruction technique Wenkai Lua) Department of Automation, Key State Lab of Intelligent Technology and System, Tsinghua University, Beijing 10084, People s Republic of China Fang-Fang

More information

Limitations of Projection Radiography. Stereoscopic Breast Imaging. Limitations of Projection Radiography. 3-D Breast Imaging Methods

Limitations of Projection Radiography. Stereoscopic Breast Imaging. Limitations of Projection Radiography. 3-D Breast Imaging Methods Stereoscopic Breast Imaging Andrew D. A. Maidment, Ph.D. Chief, Physics Section Department of Radiology University of Pennsylvania Limitations of Projection Radiography Mammography is a projection imaging

More information

A Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT

A Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT A Fast GPU-Based Approach to Branchless Distance-Driven Projection and Back-Projection in Cone Beam CT Daniel Schlifske ab and Henry Medeiros a a Marquette University, 1250 W Wisconsin Ave, Milwaukee,

More information

Enhancement Image Quality of CT Using Single Slice Spiral Technique

Enhancement Image Quality of CT Using Single Slice Spiral Technique Enhancement Image Quality of CT Using Single Slice Spiral Technique Doaa. N. Al Sheack 1 and Dr.Mohammed H. Ali Al Hayani 2 1 2 Electronic and Communications Engineering Department College of Engineering,

More information

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition

Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Validation of GEANT4 for Accurate Modeling of 111 In SPECT Acquisition Bernd Schweizer, Andreas Goedicke Philips Technology Research Laboratories, Aachen, Germany bernd.schweizer@philips.com Abstract.

More information