Read the whole of this document before unpacking your Izon equipment or proceeding to the steps below.
|
|
- Dwight Lee
- 5 years ago
- Views:
Transcription
1 Getting Started Read the whole of this document before unpacking your Izon equipment or proceeding to the steps below. 1. Take the USB drive out of your training kit and put the rest of the contents in a refrigerator. 2. Read the qnano User Manual which can be found as PDF files on the USB drive. The User Manual has detailed instrument descriptions and installation information. 3. Install the Izon Control Suite Software (CSS): a. Insert the Izon USB drive into your computer. b. An auto run prompt will ask you to run Install.exe. 4. Once Izon Control Suite software and instrument are both successfully installed, complete reading the User Manual and proceed to undertake the training course described in the Izon s TRPS Training Module PDF document on the USB drive. Important: Do not attempt to operate the equipment until successfully completing the Izon Training Programme. Additional support material is available on the support portal (KBase), sign up here: Website URL: If you have any questions that are not answered on the KBase, please contact our Support staff via KBase or directly by or skype: support@izon.com Skype: IzonSupport QN1-IQ-013(F)
2 Important Read Before Operating Izon Instrumentation Follow all directions in this document and complete the Izon Training Module before attempting to operate the instrument, they contain important safety and operational information. Use of this instrument in a manner not specified by the instructions in this guide and the training module may impair the safety protection provided. Do not operate the instrument outside its rated supply voltages or environmental range Failure to read these instructions and the training module and use the instrument in the manner specified may result in impaired performance and damage to the equipment. The following symbols are used on the instrument and in this manual:- Earth (ground) terminal. Direct Current (DC) Voltage polarity of Jack. USB Connection Caution risk of danger or impaired operation, if instructions not followed Important please read below for installation instructions and an explanation on connecting and operation of the instrument.
3 Izon Instrument Components and Installation qnano qmicro qviro-x See the qnano User Manual.pdf located in the Training Module folder on the USB drive from the training kit. See the qmicro User Manual.pdf in the Guides folder on the USB drive from the training kit. See the qviro-x Getting Started Guide in the Guides folder on the USB drive from the training kit. Powering Your Instrument IMPORTANT Plug into Earth Grounded Protected Outlets ONLY. Make sure power supply box is positioned off benches and away from fluids. To prevent heat build-up, do not cover the power-supply box. Position unit so it can easily and quickly be disconnected from mains power. Mains Operating Voltage This instrument has a universal input range and will operate from a nominal 115 V or 230 V mains supply without adjustment. Check that the local supply meets the AC Input requirement given in the Specification. Izon Instruments are only to be operated with Izon supplied leads and power supply. Failure to use the correct power supply may result in invalid operation. Do not place the power supply in a position where it can come into contact with spills or moisture. Make sure the power supply is placed away and to the rear of the instrument to avoid spills during filling the fluid cell. Computer Equipment Set-up Devices that can be connected to the equipment should be compliant with a relevant safety standard such as IEC for IT equipment or IEC for laboratory equipment and should provide double or reinforced insulation from hazardous voltage sources.
4 Do not place any computer for connecting to the Izon instrument in a position where it can come into contact with spills or moisture. Make sure Izon supplied USB cable is used. General Operating Precautions For indoor use only, to be used within the rated condition in system specifications Take care not to spill fluids on electrical parts during operation Repair and Servicing of your Izon Instrument There are no user serviceable parts. Return equipment to Izon for service. All replacement parts, cables, mains-leads, power-supply, nanopores, fluid cells must be obtained via Izon Science Ltd. Cleaning of your Izon Instrument Care and cleaning of your instrument is important for correct operation. Failure to follow the proper care instructions may result in impaired operation. Please refer to the following product documents for cleaning and care instructions; qviro-x & qnano 21 CFR part 11 installs qnano qmicro Refer to the SOP for Performing Installation Qualification Protocol for a qnano manual, section 10. Follow the instructions in Section 5 of the qnano User Manual Refer to the qmicro User Manual Take care with cleaning not to spill excess fluid on other equipment Consumables Ordering For ordering of nanopores, calibration particles, and other consumables, please see our online store at store.izon.com.
5 System Specification Item Specification Comment Environment Indoor use at altitudes up to 2000 m, Pollution Degree 2 20% to 80% RH. Operating Temperature 5 C to 25 C RMS noise performance i Typical < 10 pa For +/- 200 na range NP200 Data sampling rate 50,000 samples per second USB standard connector Max input voltage USB 2.0 Mini-B 5.00 ± 0.25 V Cable must be to relevant safety standard such as IEC for IT equipment or IEC for laboratory equipment and should provide double or reinforced insulation from hazardous voltage sources Electrical Power ii Voltage, current Power consumption 12 V (DC ), 130 ma 1.5 W At input jack on instrument PSU Output DC Input AC Output current max Output power max 90 to 264 Vac 50/60 Hz ac 12 V nom 3.75 A 45 W iii Use only Izon supplied TRG45A120-21E11 Nanopore holding stage extension range Min 41mm Max 61mm Measured across the outside of opposing holding arms. Electrical safety IEC/EN EMC IEC/EN i Under electrical interference noise may increase but will return to normal operation on end of interference. Position equipment away from electrical switching gear and interfering equipment or noise may increase under sample running conditions. ii For no equipment plugged into the Izon auxiliary interface. iii PSU module rating. Izon Instruments running normally are approx. less than 1.6W
User's Guide. Phase Sequence and Motor Rotation Tester Model
User's Guide Phase Sequence and Motor Rotation Tester Model 480403 Introduction Congratulations on your purchase of the Extech Model 408403 Motor and Phase Rotation Indicator. This handheld instrument
More informationModels 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide
Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation.
More informationMini Digital Multimeter
User Manual Mini Digital Multimeter Model MN15A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN15A MultiMeter. The MN15A offers
More informationUser Guide True RMS Multimeter Extech EX205T
User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Back to the Extech MN15/MN16 Series
More informationUSER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310
USER MANUAL Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310 Introduction Congratulations on your purchase of the Extech EX310 MultiMeter. The EX310 offers AC/DC Voltage, AC/DC Current,
More informationMini Digital Multimeter
User's Guide Mini Digital Multimeter Model MN15 Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity
More informationMini Digital Multimeter Model MN15. User's Guide
Mini Digital Multimeter Model MN15 User's Guide Introduction Congratulations on your purchase of the Extech MN15 MultiMeter. The MN15 offers AC/DC Voltage, AC/DC Current, Resistance, Diode, and Continuity
More informationAutoranging Mini Multimeter
User Manual Autoranging Mini Multimeter Model MN16A Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter.
More informationBENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL
BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,
More informationUser's Guide. Digital Multimeter. Model MN42
User's Guide Digital Multimeter Model MN42 Introduction Congratulations on your purchase of the Extech MN42 MultiMeter. The MN42 offers AC/DC Voltage, DC Current, and Resistance testing. Proper use and
More informationUser Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at
User Manual 400Amp AC Clamp Meter + NCV Model MA430 Additional User Manual Translations available at www.extech.com Introduction Congratulations on your purchase of this Extech MA430 Clamp Meter. This
More information9040/9040UK. Users Manual. Phase Rotation Indicator
9040/9040UK Phase Rotation Indicator Users Manual PN 2438546 April 2005 2005 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED
More informationEARTH RESISTANCE & RESISTIVITY TESTER
99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com BST-ET103 EARTH RESISTANCE & RESISTIVITY TESTER INSTRUCTION MANUAL INDEX 1. INTRODUCTION...
More informationModel 2380 Rack-Mount Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount
More informationUser s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389
User s Guide 600A True RMS AC/DC Clamp Meter Model 38389 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further
More informationModel A Mini AC/DC Clamp Meter. User's Guide
Model 380950 80A Mini AC/DC Clamp Meter User's Guide Introduction Congratulations on your purchase of the Extech 80A Mini AC/DC Clamp Meter. The Model 380950 measures AC/DC Current, AC/DC Voltage, Resistance,
More informationOperating Instructions
Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number 344A550 Revision 1 2006 Seaward
More informationOperating Instructions
PRIMETEST 100 PRIMETEST 100 Bracken Hill South West Industrial Estate Peterlee Co Durham SR8 2SW ENGLAND Tel: +44(0)191 5863511 www.seaward.co.uk sales@seaward.co.uk service@seaward.co.uk Part Number
More informationOPERATING INSTRUCTION. Pen-Type Digital Multimeter
OPERATING INSTRUCTION Pen-Type Digital Multimeter International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationHV-CS kv Edge Mount Triaxial Jack
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley HV-CS-1589 3 kv Edge Mount Triaxial Jack Installation Information Description The Keithley Instruments
More informationNI PXI-1042 Series Power Supply Shuttle
USER GUIDE NI PXI-1042 Series Power Supply Shuttle Introduction Unpacking The NI PXI-1042 Series power supply shuttle is a replacement part for the NI PXI-1042 Series chassis. To minimize downtime caused
More informationDigital Clamp Meter User Manual
Compact AC, AC/DC Digital Clamp Meter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents 1.Safety... 3 2.Safety Notes... 3 3.Warnings... 3 4.Cautions...
More informationCM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL
CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationOwner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español
Owner's Manual True RMS Multimeter Model No. 82023 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance Español
More informationModel 4200-CVU-PWR. Parts Package. Introduction. PA-977 Rev. C / September 2016 *PPA-977C* 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 4200-CVU-PWR Parts Package Introduction The Model 4200-CVU-PWR C-V Power Package for both the
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS: 61-773 61-775 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationNI PXIe-1062Q Power Supply Shuttle
USER GUIDE NI PXIe-1062Q Power Supply Shuttle The NI PXIe-1062Q power supply shuttle is a replacement part for the NI PXIe-1062Q chassis. Caution This power supply is not compatible with any other National
More informationUser's Guide. MiniTec TM Series Model MN25 MultiMeter
User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a
More informationAPT20. User Manual.
APT20 User Manual www.audac.eu 2 Index Introduction 5 Precautions 6 Safety requirements 6 Caution servicing 6 EC Declaration of conformity 7 Waste of Electrical and Electronic Equipment (WEEE) 7 Caution
More informationUser's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter
User's Guide 800 Amp Clamp Meters EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter Introduction Congratulations on your purchase of the EX710, EX720, or EX730 Clamp DMM.
More informationIDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-796 The Service Information provides the following information: Precautions and safety information Specifications Performance test procedure Calibration
More informationPAT-Cal 2 TECHNICAL MANUAL
Portable Appliance Tester Calibrator PAT-Cal 2 TECHNICAL MANUAL 1 Time Electronics Limited Botany Industrial Estate, Tonbridge, Kent, TN9 1RH. Tel: +44(0)1732 355993 Fax: +44(0)1732 770312 Email: info@timeelectronics.co.uk
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationETHOS Auto Ranging Digital Multimeter
ETHOS 5020 Auto Ranging Digital Multimeter 1 1. SAFETY INFORMATION SAFETY SYMBOLS Warning! Dangerous Voltage (Risk of electric shock). Caution! Refer to the user s manual before using this Meter. Double
More informationModel R5010. TRMS Digital Multimeter. Instruction Manual
INSTRUMENTS Model R5010 TRMS Digital Multimeter Instruction Manual Table of Contents Safety...3-4 IEC1010 Overvoltage Installation Category... 3 Warnings... 4 Features... 5 Specifications...5-8 Instrument
More informationCONTENTS. 1- INTRODUCTION 1.1 Introduction 1.2 General Applications and Benefits 1.3 Identification 2- HARDWARE
1 CONTENTS 1- INTRODUCTION 1.1 Introduction 1.2 General Applications and Benefits 1.3 Identification 2- HARDWARE 3- SOFTWARE DESCRIPTION 3.1 Introduction 3.2 TVS-1000 software 3.3 Software Installation
More informationLaboratory Switch Mode Power Supply Series. Instruction Manual
Laboratory Switch Mode Power Supply Series Instruction Manual Model 72-8340 1.0 ~ 60VDC 0 ~ 1.6A 72-8345 1.0 ~ 36VDC 0 ~ 3A 72-8350 1.0 ~ 20VDC 0 ~ 5A Copyright 2008, all rights reserved Tenma Test Equipment
More informationRTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version
RTD Process Calibrator User s MANUAL Safety Information RTD Process Calibrator User s Manual To avoid possible electric shock or personal injury: Never apply more than 30V between any two jacks, or between
More informationNI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE
NI PXI-1042 POWER SUPPLY SHUTTLE USER GUIDE Introduction Unpacking The NI PXI-1042 power supply shuttle is a replacement part for the PXI-1042 chassis. To minimize downtime caused by a power-supply failure,
More informationINSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage
INSTRUCTION MANUAL Model 380942 True RMS AC/DC 30A Mini Clamp-on Meter True RMS AC Current and Voltage Measure low current with high resolution to 0.1mA AC and 1mA DC Auto Power Off One touch DCA zero
More informationMODEL 805 USER MANUAL
MODEL 805 USER MANUAL All Rights Reserved Page 1 of 12 UNPACKING & INSPECTION Save all packing materials they are required for returns and warranty service. Inspect the 805 and packing materials for any
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationModel 8010 High Power Device Test Fixture Interconnection Reference Guide
Model 8010 High Power Device Test Fixture Interconnection Reference Guide Safety precautions Observe the following safety precautions before using this product and any associated instrumentation. Although
More informationDM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER
DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER SAFETY INFORMATION The following safety information must be observed to ensure maximum personal safety during the operation of this meter: This meter is
More informationManual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.
Manual Supplement Manual Title: 601PRO XL Operators Supplement Issue: 5 Part Number: 2234222 Issue Date: 9/18 Print Date: April 2005 Page Count: 5 Revision/Date: This supplement contains information necessary
More informationSOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1
SOUND LEVEL METER DVM1351 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1351 SOUND LEVEL METER 1 SAFETY INFORMATION l Read the following safety information carefully before attempting to operate
More information80W (16V/5A) Power Supply with USB Output. User Manual
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1325 80W (16V/5A) Power Supply with USB Output User Manual 1325 Volt. C.V. Amp. C.C. V OUTPUT ON/OFF A
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More informationModel: Pro93 TRUE RMS LEAKAGE CURRENT TESTER
Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER CONTENTS TITLE PAGE I. Safety Information.......1 Environmental Conditions... 1 Explanation of Symbols..... 1 II. Specification..... 2 General Specification...
More informationOWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER
OWNER S MANUAL 9908-TE HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER IMPORTANT! Read and understand this manual before using the instrument. Failure to understand and comply with
More informationAutoRanging Digital MultiMeter
Owner's Manual AutoRanging Digital MultiMeter Model No. 82175 CAUTION: Read, understand and follow Safety Rules and Operating Instructions in this manual before using this product. Safety Operation Maintenance
More informationMid-span 802.3af PoE Injector. Installation Guide KPOE-100
Mid-span 802.3af PoE Injector Installation Guide KPOE-100 Doc. 070521 1 (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced in any form or by any means or used
More informationThis 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount
More information±15 V Current-Limited Power Supply
USER S GUIDE ±15 V Current-Limited Power Supply Model 0901 Newport Corporation 3635 Peterson Way Santa Clara, CA 95054 www.newport.com/newfocus EU Declaration of Conformity We declare that the accompanying
More informationUSB-2001-TC. USB-based Thermocouple Input. User's Guide
USB-2001-TC USB-based Thermocouple Input User's Guide Document Revision 6A November 2014 Copyright 2014 Trademark and Copyright Information Measurement Computing Corporation, InstaCal, Universal Library,
More informationAllworx 24x Service and Troubleshooting Guide
Allworx 24x Service and Troubleshooting Guide -PAGE INTENTIALLY LEFT BLANK- Table of Contents 1 Safety Instructions...1 1.1 Electrical...1 1.2 Electrostatic Discharge...1 2 Chassis Views...2 3 Exterior
More informationQuick Start Guide and Health and Safety Information
D397-10-880 Issue F Original Quick Start Guide and Health and Safety Information Turbo Instrument Controller (TIC) Description TIC Instrument Controller 3 Gauge TIC Instrument Controller 6 Gauge TIC Instrument
More informationUser s Guide. 600A AC Clamp Meter. Model 38387
User s Guide 600A AC Clamp Meter Model 38387 Safety International Safety Symbols This symbol, adjacent to another symbol or terminal, indicates the user must refer to the manual for further information.
More informationAgilent U2722A USB Modular Source Measure Unit. Data Sheet
Agilent U2722A USB Modular Source Measure Unit Data Sheet Features and capabilities Three-channel SMU Four-quadrant operation (±20 V) Maximum current output of 120 ma per channel High measurement sensitivity
More informationINSTRUCTION MANUAL. Instruction Manual. Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer
INSTRUCTION MANUAL Instruction Manual Analog Multi-Tube Vortexer Digital Multi-Tube Vortexer Table of Contents Package Contents............ 1 Warranty............ 1 Installation............ 2 Maintenance
More informationMARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals
Martindale Electric will carry out routine calibration (on a chargeable basis) if the instrument is returned, carriage paid, to the address on the final page of this document. Alternatively, a chargeable
More informationModel 2380 Rack-Mount Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount
More informationOPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual
OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS Model Nos. OPR065-48S / OPR065-48R Manual Revision F July 2009 Optimal Power Supplies LLC www.optimal-power.com i
More informationEPS Power Supply
EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------
More information1-36V, 0-3A DC Power Supply
1550 1-36V, 0-3A DC Power Supply User Manual Safety Summary The following safety precautions apply to both operating and maintenance personnel and must be followed during all phases of operation, service,
More informationF-712.PM1 Optical Power Meter
MP165E, applies to F-712.PM1 F-712.PM1 Optical Power Meter Optical Power Meter for 400-1550 nm Wavelength Range, to 1 ma Input Current, 20 khz Signal Bandwidth, Logarithmic Output ±5 V, Benchtop Device,
More information38 MHz Passive Voltage Probe R&S RT-ZP1X
Manual 38 MHz Passive Voltage Probe R&S RT-ZP1X 1333.1370.02 Printed in Germany Test and Measurement 2 Manufacturer ROHDE & SCHWARZ For comprehensive information about Rohde and Schwarz, please visit our
More informationAutoranging Mini Multimeter Model MN16A
User's Guide Autoranging Mini Multimeter Model MN16A Introduction Congratulations on your purchase of the Extech MN16A Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,
More informationR5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com
Model R5050 TRMS AC/DC Clamp Meter Instruction Manual reedinstruments com Table of Contents Safety... 3 Features... 4 Specifications...4-6 Instrument Description...7-8 Measurement Procedures...9-12 Battery
More informationZ-350 FAZER USER MANUAL
www.clubsoundrent.nl Z-350 FAZER USER MANUAL English Français Deutsch 2013 Antari Lighting and Effects Ltd. 1 User Manual Safety Information Please read the following safety information carefully before
More informationInstallation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A
Installation Guide Standalone/Spare V6 SDI QBox QBox-V6 Standalone/Spare V6 SDI QBox Part No. A9009-0004 EN www.autocue.com Copyright 2017 All rights reserved. Original Instructions: English All rights
More informationCLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide
CLAMP MULTIMETER METRACLIP 85 ENGLISH Start Guide Clamp Multimeter METRACLIP 85 English You have just acquired an METRACLIP 85 clamp multimeter and we thank you. For best results from your device : read
More informationEarth Resistance and Resistivity Tester
User Manual Earth Resistance and Resistivity Tester Model GRT350 Additional User Manual Translations available at www.extech.com Introduction Thank you for selecting the Extech Instruments Model GRT350
More informationP5200A Series High Voltage Differential Probes. Installation and Safety Instructions & Product Documentation CD
xx P5200A Series High Voltage Differential Probes ZZZ Installation and Safety Instructions & Product Documentation CD *P071288902* 071-2889-02 Copyright Tektronix. All rights reserved. Licensed software
More informationRS Stock No Instruction Manual RS Input Data Logging Thermometer
RS Stock No. 730-0458 Instruction Manual RS-1384 4 Input Data Logging Thermometer EN FR IT DE ES TABLE OF CONTENTS / EN TITLE TABLE OF CONTENTS PAGE 1. INTRODUCTION FEATURE... 1 2. SPECIFICATIONS... 2
More informationQuick Start Guide. 240 Series Cryogenic Sensor Input Module. 1 Model 240 Quick Start Guide
Quick Start Guide 240 Series Cryogenic Sensor Input Module 1 Model 240 Quick Start Guide 2 Model 240 Quick Start Guide Safety Precautions Observe these general safety precautions during all phases of instrument
More informationSAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION. NI CompactDAQ Four-Slot Controller with Quad-Core Processor
SAFETY, ENVIRONMENTAL, AND REGULATORY INFORMATION NI cdaq -9136 NI CompactDAQ Four-Slot Controller with Quad-Core Processor This document includes compliance precautions and connection information for
More informationATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual
ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual EN 61010-2-032 CAT II 600V, CAT III 300V Pollution Degree 2 SYMBOLS showed on the clamp meter or in this manual: Caution, risk of danger. Refer to accompanying
More informationOX 5022-CK OX 5042-CK
QUICK START USER GUIDE OX 5022-CK OX 5042-CK Statement of Compliance Chauvin Arnoux, Inc. d.b.a. AEMC Instruments certifies that this instrument has been calibrated using standards and instruments traceable
More informationModel INSTRUCTION MANUAL DIGITAL MULTIMETER
Model 57040 INSTRUCTION MANUAL DIGITAL MULTIMETER SAFETY INFORMATION This multimeter has been designed according to IEC 1010 concerning electronic measuring instruments with an overvoltage category (CAT
More informationUser's Guide. Extech AM A AC Analog Clamp Meter
User's Guide Extech AM300 300A AC Analog Clamp Meter Introduction Congratulations on your purchase of the Extech AM300 Analog Clamp Meter. This device measure AC Voltage and Current, DC Voltage, and Resistance.
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationSUBWOOFER SYSTEM YST-MSW10
ACTIVE SERVO PROCESSING SUBWOOFER SYSTEM YST-MSW10 Active Servo SUBWOOFER SYSTEM YST-MSW10 Active Servo HIGH CUT HIGH LOW OWNER S MANUAL MANUAL DE INSTRUCCIONES CAUTION RISK OF ELECTRIC SHOCK DO NPT OPEN
More informationYST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology
CAUTION SUBWOOFER SYSTEM Active Servo RISK OF ELECTRIC SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS SIDE. REFER SERVICG TO QUALIFIED
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationCOGNEX. Checker SensorView. Quick Reference Guide
COGNEX Checker SensorView Quick Reference Guide 890 SensorView 890 Overview SensorView 890 provides self-contained IP-65 touchscreen configuration, control, and monitoring of one or more Checker 4G series
More informationHCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control
HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control 1. INTRODUCTION User Manual This family of efficient, upgraded SMPS with small form factor,
More informationModel 7705 Control Module
www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be
More informationKeithley Instruments Customer Documentation Series 2600A UL Safety Supplement
Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 1-888-KEITHLEY www.keithley.com Keithley Instruments Customer Documentation Series 2600A UL Safety Supplement 1. Introduction The Keithley
More informationST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual
ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual HB2ST1400000 CONTENTS 1 Introduction... 1 2 Accessories... 1 3 Safety Precaution... 1 4 Meter Description... 2 5 Operation... 3
More information1. Safety Precautions (Read these precautions before use.)
R P5102S/N/N1 HMI Installation Guide Thank you for purchasing FATEK HMI. Before installing or operating the unit, please read this installation guide carefully to ensure correct use. 1. Safety Precautions
More informationTT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL
TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL This probe is in compliance with IEC-1010.1, IEC-1010.2-031 CAT I or CAT II, Pollution Degree 2. 1. Safety Terms and Symbols Terms appear in this manual:
More informationCVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com CVU-200-KIT 200 V Bias Tee Kit Description The CVU-200-KIT Bias Tee Kit consists of three 2600-RBT-200
More informationPart No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A
Part No. Z1-109-820, IA001705 Jul. 2016 OPERATION MANUAL High Voltage Digitalmeter 149-10A Use of Operation Manual Please read through and understand this Operation Manual before operating the product.
More informationHigh Precision Quad Output DC Power Supply
User's Guide High Precision Quad Output DC Power Supply Model 382270 Introduction Thank you for selecting the Extech Model 382270. This device is shipped fully tested and calibrated and, with proper use,
More informationKeysight U8030 Series Triple-Output DC Power Supplies
Keysight U8030 Series Triple-Output DC Power Supplies Data Sheet Introduction Higher Power. Better Reliability. Unrivalled Performance. Keysight Technologies, Inc. extends its family of basic DC power
More informationUSER MANUAL. True RMS Multimeter. Extech EX430A
USER MANUAL True RMS Multimeter Extech EX430A Introduction Congratulations on your purchase of the Extech EX430A True RMS Autoranging Multimeter. This meter measures AC/DC Voltage, AC/DC Current, Resistance,
More informationDLRO 200 High Current, Low Resistance Ohmmeter
M DLRO 200 High Current, Low Resistance Ohmmeter USER MANUAL GSAFETY WARNINGS THESE SAFETY WARNINGS MUST BE READ AND UNDERSTOOD BEFORE THE INSTRUMENT IS USED. n DLRO200 is supplied without a plug terminating
More information