1 SYCON 55xxSS Automatic Power Factor Controller Systems & Controls (Sangli) Pvt. Ltd.
2 Introduction 2 Automatic Power Factor Controller SYCON 55xxSS 2 Features 2 Models 3 Control Principle 3 Installation 4 Electrical connection diagram 4 Operation 5 At Power ON 5 Default Mode 5 DISPLAY Mode 7 CT Primary display 7 Target PF display 8 SET1 Mode 8 Set CT Primary 8 Target PF 9 SET2 Mode 10 Auto Identification Mode 10 Manual Feed Mode 11 TEST Mode 12 Low Current Mode 13 Troubleshooting 13 Appendices 14 Appendix 1 Technical Data 14 Appendix 2 Default Settings 15 Appendix 3 Test Certificate 16 1
3 Introduction Some electrical loads such as motors found in large machines, air conditioners etc can cause electrical system to be inductive, resulting in severely lagging power factor. This means energy is being wasted, consumer has to pay large electricity charges. The simple solution to this is to connect or disconnect power factor correction capacitors according to the requirement. Manual switching of these capacitors is not suitable for the rapid fluctuating loads. Such systems therefore require continuous personal attention to make necessary corrections. So some kind of automatic control system is required to ensure maximum benefit from these capacitors. This is achieved by SYCON Automatic Power Factor Controller. The main use of the APFC unit is to switch ON or OFF the capacitors according to the capacitive KVAR requirement to balance the inductive KVAR produced in the system by inductive loads. If the same APFC relay can provide many other features such as display of system KVA, system KW and system KVAR is advantageous to the user because it helps user to understand the system loads at the same time. This relay will provide such additional features than the existing APFC model in this range. Automatic Power Factor Controller SYCON 55xxSS SYCON 55**SS is automatic power factor controller equipped with a variety of functions. Features SYCON 55**SS comes with many modern features at incredibly low cost. It enables user to get maximum 2
4 benefits from it. SYCON 55**SS is an example of stateof-the-art technology". Some of the salient features listed down here, o Complete menu guided programming and operation. o Four digit LED display. o Smart switching of capacitors. o Automatic or Manual capacitor value feed. o Adjustable CT primary and Target PF settings. o Display of system KVA, KW, KVAR, and Shortfall KVAR. o Test mode facility at no load for panel builders. Models SYCON 55**SS comes in various models as listed below. SYCON 5504SS SYCON 5506SS SYCON 5508SS SYCON 5512SS SYCON 5516SS 04 Steps 06 Steps 08 Steps 12 Steps 16 Steps Control Principle SYCON 55**SS controls the capacitors switching with smart fit algorithm. First the accurate power factor is computed with continuously monitoring the voltage and current. Considering target power factor required to maintain PF at set PF value, the shortfall is calculated. From all the available capacitors (Capacitors which are already ON or which are recently switched OFF are not considered as they are discharging) the smart fit 3
5 capacitor is selected and switched ON or OFF according to shortfall condition. This mode of operation ensures the smart use of all the capacitors to achieve an average power factor which is nearest to the target PF. Installation SYCON 55**SS is easy to install with its compact size and low weight. It is easily mounted on the panel door with minimum efforts. A cutout of 138mm X 138mm is required to be cut in the panel door where you wish to install the product. Electrical connection diagram The typical wiring diagram is shown in figure below. Supply voltage is phase to phase voltage. But the current transformer (CT) must be in the remaining third phase. CT must have been placed before the load for which we wish to control the power factor. Capacitors contactors are connected to the relay as shown in figure below. Phase to neutral connection is recommended for the contactors. R Y B N To Load To Capacitors R Y B CT C C1 C2 C3 C4 C5 C6 4
6 Operation SYCON 55**SS is a menu guided control system apart from its basic function of smart capacitor switching. It provides various other functions to the user which can be used to enrich the overall quality of power system. At Power ON When instrument is switched ON, it will display SYCN (SYCON) for few seconds and then it will display APFC. The startup display will look like this If CT polarity is wrong the display will flash the message b Ct, then reverse the CT correction and restart. (Note: It is advisable to put on the inductive load on while checking for CT connection) Default Mode This is the most basic and widely used mode. In this mode, capacitor switching is automatically managed. Also during this mode, user can see various basic operating parameters. The state chart diagram is as shown in figure below. 5
7 Default State Power Factor Display DEC DEC DEC DEC KVA Display KW Display KVAR Display Shortfall Display DEC Power Factor Display Both TIME OUT TIME OUT TIME OUT OR (BOTH KEYS AND NOT Lo C) TIME OUT OR (BOTH KEYS AND NOT Lo C) DISPLAY MODE SET 1 MODE SET 2 MODE TEST MODE DEC DEC CT Primary Target PF BOTH CT Primary Target PF BOTH BOTH Auto Feed BOTH Manu Feed While displaying the Power Factor the LED shows the Lagging and Leading condition by glowing respective LED's. Here by using Increment OR Decrement keys user can choose the display of other parameters. The respective LED of that parameter glows while display is indicating the value of that parameter. The other parameters are listed below, 1. KVA 2. KW 3. KVAR 4. Short fall. 6
8 DISPLAY Mode User can see settings, other advanced parameters such as CT primary, Target PF and capacitors values in this mode. To enter display mode one should press both keys simultaneously in default state. The Stat chart for this mode is as shown below, DISPLAY MODE DEC CT Primary DEC BOTH Target PF BOTH Display CT Primary Display Target PF In this display mode first the display will look like this All the settings set by user are displayed in this mode. User can scroll up and down by pressing the required parameter by pressing the both keys simultaneously. CT Primary display Here user can see the CT primary setting. Here first display will show the message as - If user press both keys then user can see the CT primary display. And again by pressing both keys user will come back to previous menu. If user press key user 7
9 can go for next menu i.e. target power factor display and if user press DEC key then user can go for display mode. Target PF display Here user can see the target power factor setting. Here first display will show the message like - If user press both keys then user can see the target power factor setting. And again by pressing both keys user will come back to previous menu. If user press key user can go back to display mode. SET1 Mode When user Press both keys simultaneously, one can enter SET1 mode. Here two settings are provided for user, 1. CT primary Setting By pressing key 2. Target Power Factor Setting By pressing DEC key The SET1 will be displayed on the screen as follows - Set CT Primary In this mode, the selected CT primary is displayed as- This display flashes for few seconds. When user 8
10 presses the key, the CT primary is increased. When user presses DEC key, the CT primary is decreased. If user presses and DEC key at a time, the CT primary displayed at that time is saved as new CT primary. Display will show done message and system will exit to default mode. The increment and the decrement values are as CT Primary Range Increment/ decrement by 5 to to Target PF In this mode, the target power factor is displayed as This display flashes for few seconds. In this mode, the target power factor can be set by the user. When user presses the key, the target power factor is increased. When user presses DEC key, the target power factor is decreased. If user presses and DEC key at a time, the target power factor displayed at that time is saved as new target power factor. Display will show done message and system will exit to default mode. To indicate whether the set power factor is lag or lead, respective LED is set to glow. 9
11 The increment and the decrement value are as Target Power Factor Range Increment/ decrement by 0.70 Lag to 0.80 Lead 0.01 SET2 Mode One can enter in to SET2 mode by pressing both keys simultaneously when display is showing SET1. SET2 mode is provided for two settings listed below. 1. Auto identification of Capacitor Value By pressing key 2. Manual Feeding of Capacitor Value By pressing DEC key The SET 2 will be displayed on the screen as follows - Auto Identification Mode When we press Increment key in SET2 mode we can enter in to this mode, in this mode auto identification is displayed as This display flashes for few seconds. Before the auto identification of the capacitor values, system will turn OFF all the ON capacitors. During auto identification the 10
12 system will turn ON and OFF the capacitors one by one and store the capacitor value in the memory. When system turns OFF previous capacitor and turns ON next one, it will display the value of previous capacitor. Display will show done message after completing all stages and system will exit to default mode. Manual Feed Mode In this mode Manual Feed displayed as This display flashes for few seconds. Then it displays the CAP1. When we press increment in this mode we can change the capacitor number. In this mode Capacitor number is displayed as When we press key at the last capacitor number display or when we press the DEC key at the first capacitor number display, EXIT mode will appear as- When the user presses key, the mode will change to first capacitor number display and when user presses DEC key, the mode will change to last capacitor number display. When user presses both keys in this 11
13 mode, user can exit from capacitor manual feed mode to the default mode. When we press both keys in capacitor number display mode the display will show the capacitor value of that capacitor. We can change the capacitor value by pressing increment (to increment the value) and decrement (to decrement the value). If user presses and DEC key at a time, the Capacitor Value displayed at that time is saved as new Capacitor Value. Display will show done message and system will exit to capacitor number display. The increment and the decrement is done as Capacitor Value Range TEST Mode Increment/ decrement by 1 to The TEST mode is operative only after confirmation of low current mode. To enter into TEST mode one has to press both keys simultaneously at SET2 mode. The TEST mode is displayed as This display flashes during entire TEST mode, and the system will return to the initial mode after completing the test mode automatically by displaying message done. During test mode the system will switch on all the capacitors in one run and the switch off all the capacitors in the second run by FIFO principle. 12
14 Low Current Mode When total load reduces to about 2% of the primary current rating of the rating of the CT the system automatically switches OFF all the capacitors one by one and the display will be shown as- This display flashes during Low Current mode. The system will return to the default mode after the load current is more than 2% of the CT primary current. Troubleshooting Problem Power Factor is very poor Display is blank OR instrument does not respond to any key Display shows Lo C (low current) Controller does not operate though inductive load is heavy. Possible Solution Check the target setting Wait for 10 seconds and if still the problem exists, check the power supply connections Check the current coming to CT connection of the controller. If it is below 2% of full load current, the instrument is in low current condition. Check the settings. 13
15 Appendices Appendix 1 Technical Data Specification Value Supply Voltage 440V +/- 15% Current Input CT --/5A Frequency 50 Hz +/- 5% Over Voltage (R-Y) 470V +/- 1% Low current Relay output Stages 4 to 16 Switching Program Target Power Factor Switching ON delay Discharge Time (OFF-ON delay) Mechanical Specifications 2% (70mA) In 4% (230mA) Out 10A at 250V AC Smart (KVAR based) 0.70 Lag to 0.80 Lead 5 sec 25 sec Size Weight Front bezel size Panel cutout size 137mm L x 137mm W x 86mm D 1 kg maximum 144mm x 144mm 138mm x 138mm 14
16 Appendix 2 Default Settings Settings Value Target Power Factor 1.00 CT Primary 5 ON Delay OFF Delay 5 Sec 25 Sec Stages 4/6/8/12/16 depending on the model 15
17 Appendix 3 Test Certificate Serial No. Type Date of Inspection Test Conditions Supply Voltage (R-Y) V Current in B phase Amp Output Contacts Load KVAR Display OK/Not OK Insulation Test OK/Not OK Power Factor 0.6 IND 0.7 IND 0.8 IND 0.9 IND 0.95 IND CAP 0.9 CAP LOW Current Low current IN Low Current OUT Test Engineer For SYSTEM & CONTROL (SANGLI) PVT.LTD 16
18 Our Other Products Power Factor Controller t SYCON 66** t SYCON 66**SS t SYCON 55** t SYCON 55**2D t SYCON 5503ND Thyristorised Capacitor Switching Module Automatic KVA/KW Demand Controller t SYCON 4300SS t SYCON 4400 t SYCON 4400KW Comprehensive Motor Protection Relay t SYCON IMPR 2220 t SYCON MMR 2110 Earth Leakage Relay and Panel Meters SYSTEMS & CONTROLS (SANGLI) PVT.LTD C-24 M.I.D.C. Miraj SANGLI, MAHARASHTRA,INDIA Tel: / FAX: sales@sycon.co.in, info@sycon.co.in Visit us at :
APFC-07/nn. Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation.
Low-Cost, Single-CT, Automatic Power Factor Controller for Balanced Three-Phase Reactive Power Compensation User Manual Version: 2.0 Page 1 of 25 Dated: 5 th March 2017 CAUTIONS: NOTE These instructions
More informationPFC-10 Power Factor Controller
PFC-10 Power Factor Controller Instruction Manual Ver. 6.0 / 2002 (2-2005 update) Table of Contents Page Subject 3 Starter ion 4-5 Installation Notes 6-7 Terminals Review & Control Wiring 8 Front-panel
More informationTechnical Specifications. Multi Function Meter
Technical Specifications of Multi Function Meter (SPM300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationTechnical Specifications. Dual Source Energy Meter (EB / DG)
Technical Specifications of Dual Source Energy Meter (EB / DG) (SPMG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com
More informationInstruction Guide. For. TAS Auto-Manual Controller (AMC)
Instruction Guide For TAS Auto-Manual Controller (AMC) TAS POWERTEK PVT. LTD. VERSION 1.0 Updated on: June 04, 2015. Page 1 of 9 Index 1) Introduction.. Page 3 2) Specifications.. Page 3 3) Operation..
More informationTechnical Specificaions. kwh Energy Meter
Technical Specificaions of kwh Energy Meter (SPK301) Class 1.0S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email : info@spowerz.com
More informationPower Factor Controller
Elnet LTC Power Factor Controller Table of Contents CHAPTER 1 Electrical Wiring...3 1.1 Electrical Connections...3 1.2 Electrical Wiring Diagrams...5 1.3 Indication Leds...7 1.4 Test Capacitors Screen...8
More informationHAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL
HAT600 Series HAT600/HAT600I/HAT600B/HAT600BI ATS CONTROLLER USER MANUAL ZHENGZHOU SMARTGEN TECHNOLOGY CO.,LTD CONTENT 1 OVERVIEW... 5 2 PERFORMANCE AND CHARACTERISTICS... 6 3 SPECIFICATION... 8 4 OPERATING...
More informationNewton+ AUTOMATIC POWER FACTOR CORRECTION RELAY
Newton+ Operational Manual USER S MANUAL Newton+ AUTOMATIC POWER FACTOR CORRECTION RELAY This document contains the latest technical information about Automatic Power Factor Correction Relay, Newton+ which
More informationPOWER FACTOR REGULATORS
POWER FACTOR REGULATORS computer max 6 / computer max 12 Instructions Manual ( M98228201-03-09B ) - 1 - Index 1 INTRODUCTION AND SAFETY RECOMMENDATIONS... 3 1.1 DELIVERY SPOT CHECK... 3 1.2 STARTING SCREEN...
More informationAutomatic Power Factor Correction Relay
Automatic Power Factor Correction Feautures Ÿ Ÿ Feeder KVAR entry through Keyboard. Ÿ Fine tuning possible ( independent of ratio's) Ÿ absolute value of KVAR Ÿ User entered parameter is stored in non-volatile
More informationTechnical Specifications. Dual Source kwh Energy Meter
Technical Specifications of Dual Source kwh Energy Meter (SPKG300) Class 0.5S Sai PowerrZerve 29/3B, Rajalakshmi Nagar, 1 st Main Road, Velachery Bye Pass, Chennai 600 042. Website :www.spowerz.com Email
More informationInstallation Manual for D244X Series 24-volt Power Supplies
Installation Manual for D244X Series 24-volt Power Supplies D2441-B D2441-C D2443-B D2443-C D2445-B D2445-C D2400 Series 1A 24 volts 1A 24 volts 3A 24 volts 3A 24 volts 5A 24 volts 5A 24 volts Dycon Power
More informationInstruction Manual for Automatic Voltage Regulator
0 Instruction Manual for Automatic Voltage Regulator Client: 1 Off: 21, Global City,Ganganagar,Meerut-250 001: +91-750036664, info@eeepowersolutions.com Works: D-59, Udyogpuram, Partapur, Meerut +91-121-2440121:
More informationTHREE PHASE AC POWER MONITOR
USE MANUAL POTON POWE CONTOL PVT. LTD., PUNE THEE PHASE AC POWE MONITO minal Input Current:-5 Amp 1] Accuracy ange for 5 Amps = 120 % nominal. 3] urden < 0.5 VA per phase. 4] Overload 4.0x nominal continuous
More informationFeatures and Benefits
Medical Safety Testing System MedTEST provides advanced test functionality while increasing efficiency for medical device manufacturers. It complies with test requirements called out in common medical
More informationHAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL
HAT560NC SERIES (HAT560NC /HAT560NBC) ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO., LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co.,
More informationGE Power Management. MMII Intelligent MCC Controller
A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control
More informationR & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.
R & D SPECIALTIES 2004, by R & D Specialties, Inc. All Rights Reserved. No part of this document may be copied or reproduced in any form or by any means without the prior written permission of R & D Specialties.
More informationPF Controllers BR6000 Series
PF Controllers BR6000 Series Intelligent User-friendly Cost-effective Version 5.0 General Controllers for PFC are of major importance in the PFC system. They measure the actual power factor and connect
More informationPowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet
PowerLogic power-monitoring units power meter Technical data sheet 2011 Basic energy meters Functions and characteristics PE86261 PE86260 PowerLogic PM1000 power meter. The PowerLogic power meters are
More informationBillion SG3015. Compact ZigBee Power Meter Series. Fully complied with IEEE
T1 T2 T3 Single phase- 2 wire Billion SG3015 T4 Compact ZigBee Power Meter Series The Billion SG3015 series is a cost-effective energy monitoring and management solution deployed in Home Area Networks,
More informationModel LSMT4 Multi Power Transducer PC CONFIGURATOR SOFTWARE Model: LSCFG Ver. 1.1 USERS MANUAL
Model LSMT4 Multi Power Transducer PC CONFIGURATOR SOFTWARE Model: LSCFG Ver. 1.1 USERS MANUAL 5-2-55, Minamitsumori, Nishinari-ku, Osaka 557-0063 JAPAN Tel: +81-6-6659-8201 Fax: +81-6-6659-8510 http://www.m-system.co.jp/
More informationEmergency lighting units PC COMBO
PC TC-DEL TC-TEL TC-DD PC CFL, 220 240 V 50/60 Hz Compact fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For compact fluorescent lamps For manual testing
More informationDKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY
datakom@datakom.com.tr http://www.datakom.com.tr Tel: +9-216 466 84 6 Fax: +9-216 364 65 65 DKM-45 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY INTRODUCTION The DKM-45 is a low cost precision
More informationS-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter
S-14 Compact Digital Multimeter S-14 Compact Digital Multimeter SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation at this meter
More informationInstallation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control
Installation Manual for D155X Series of 12V Switched Mode Power Supply for Access Control D1551A D1551B D1551P D1553B D1553C D1553P D1555B D1555C D1555P D155X Series Part Numbers 1A 12 volts in A box 1A
More informationDigital Multifunction Meters. Digital Multifunction Meters
Digital Multifunction Meters Digital Multifunction Meters DIGITAL MULTIFUNCTIOL METERS SECTION INDEX 1. MFM 3410 3420 3430 3440 6100 & 2000 - Multifunctional Instrument Series 2. EM 3490, 3490SS, 3490DS
More informationHAT160 ATS CONTROLLER USER MANUAL
HAT160 ATS CONTROLLER USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark SmartGen make your generator smart SmartGen Technology Co., Ltd No. 28 Jinsuo Road Zhengzhou
More informationOperation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter
Operation Manual MODEL 2TX 2-wire Isolated ph/orp Transmitter 0 2TX CONTENTS INITIAL INSPECTION.....2 INTRODUCTION......2 ASSEMBLY...3 PREPARATION....4 CONNECTING THE ELECTRODE...4 CONNECTING THE TEMPERATURE
More informationPower System Network Simulator (PSNsim)
The PSNsim is hardware simulator that simulates all parts of power system from generation to utilization. The PSNsim is a scaled down model of the real power system that provides an experimental environment
More informationHVD300 VOLTAGE DETECTION RELAY MULTIFUNCTIONAL PROTECTION MODULE USER MANUAL
HVD300 VOLTAGE DETECTION RELAY MULTIFUNCTIONAL PROTECTION MODULE USER MANUAL SMARTGEN (ZHENGZHOU) TECHNOLOGY CO.,LTD. Chinese trademark English trademark Smartgen make your generator smart Smartgen Technology
More informationRapidus Power Factor Controller
Rapidus Power Factor Controller Moduler design No connector cables No fixing screws State of the art technology Easy mounting on panels connection to system Dynamic Capacitor Monitoring DCM is a supreme
More informationUSER S MANUAL. XPERT Electrical Power Meter. Trinity Energy Systems Pvt. Ltd. TRINITY. Xpert Operational Manual
USER S MANUAL XPERT Electrical Power Meter This document contains the latest technical information about Xpert which is a microcontroller based Electrical Power Meter. The product Xpert is sophisticated
More informationGV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000
GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the
More informationEarth Continuity Monitor
Continuity Monitor For Model systems switching ELECTRONIC ENGINEERS Leaders in : Voltage-Dip Proofing Continuity Monitoring Contents Introduction... 3 Theory of operation... 3 Description... 4 Front panel
More informationPortable Appliance Tester KT75 OPERATORS MANUAL
Portable Appliance Tester KT75 OPERATORS MANUAL CONTENTS 1.0 INTRODUCTION 3 2.0 SAFETY 3 3.0 FEATURES 4 3.1 Alpha numeric keypad 4 3.2 Expert Mode 4 3.3 Dual voltage operation 4 3.4 Help facility 4 3.5
More information5.1. Motor Protection and Monitoring. Contents. Product Overview. Monitoring Relays. D64R Series Digital Ground Fault Relays...
.1 Ground Fault Relays and Monitors Contents Description Current.................. Phase................... Voltage.................. Ground Fault Relays and Monitors D64R Series Digital Ground Fault Relays....
More informationMonitoring Box IMA-BOX
Monitoring Box Version externe / External version Installation_Manual_Monitoring_Box VA.6 1 * Votre énergie, vos règles Monitoring Box Indice des modifications / Modification Index Indice / Index Date
More informationTel: AC Power for Business-Critical Continuity TM
Tel: +852-2690-4118 AC Power for Business-Critical Continuity TM Anticipating Technology Changes Through Adaptive Architecture Today, you need a power infrastructure that can work across your enterprise
More informationNEUTRAL GROUNDING RESISTOR WITH, N.G.R. MONITORING & PROTECTION RELAY
EUTAL GOUDIG ESISTO WITH,.G.. MOITOIG & POTECTIO ELA MODEL: AC/33/EL&M/10k, AC/66/EL&M/20k PAT O.: 1503300091, 1506600092 APPLICATIO There are power distribution networks which feed certain earth-fault
More informationData Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D
WPM 770 Data Sheet 679.D.141.02 Digital Multifunctional Power Meter with LCD Display and Application The digital Weigel Power Meters WPM 770 have been designed to display the electrical parameters in low
More informationPG Softstarter Installation Manual for 5A, 9A and 16A Controllers
PG Softstarter Installation Manual for 5A, 9A and 16A Controllers Important User Information The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many
More informationAutoranging True RMS Multimeter User Manual
Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.
More informationPOWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual IM2492WVPF-1
POWER SERIES Plus Watt-VAR / Watt-Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.
More informationDIGITAL PROCESS CONTROLLER
1 DPC 965 M R1 R2 R3 R4 TX RX PROG [OPERATOR S MANUAL] 2 Contents Section 1 specification.page 4 Section 2 system Programming Page 4 to 11 Section 3 Precautions..Page 11 Section 4 Connection Diagram.Page
More informationFroment. SIGMA IHT Version 4 - Quickstart Guide
SIGMA IHT Version 4 - Quickstart Guide This Quickstart guide, along with the in-built help, will help you get the best out of your Sigma IHT. The Sigma Intelligent Hand-held Terminal (IHT) provides full
More informationOPERATING INSTRUCTION
OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationNIDEC-SHIMPO INSTRUMENTS
Series FGE-HXY Force Gauges Operation Manual NIDEC-SHIMPO INSTRUMENTS Do not operate or store instrument in the following locations: Explosive areas, near water, oil, dust or chemicals; areas where the
More informationModular, scalable, high-efficiency power protection for data centers
Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers The right-sized UPS for demanding business-critical applications The Schneider Electric Symmetra PX 96/160
More informationSeries FGE-XY Force Gauges Operation Manual
Series FGE-XY Force Gauges Operation Manual Do not operate or store instrument in the following locations: Explosive areas, near water, oil, dust or chemicals; areas where the temperatures can exceed 104
More informationImportant Safety Notice
! Important Safety Notice It is the responsibility of the person installing the electrical equipment to ensure that the installation meets the requirements of the IET wiring regulations and is therefore
More informationTelephone Controller INSTRUCTION MANUAL MODEL CT TABLE OF CONTENTS SUMMARY INSTALLATION Connection to an Automatic Device...
INSTRUCTION MANUAL Telephone Controller We thank you for trusting Aube technologies and hope that you will be entirely satisfied. For any questions concerning the CT241 telephone remote control, please
More informationTNY Series-Multifunction Panel Meter
PROCOM TNY Series-Multifunction Panel Meter Rev.-01 TNY Series-Multifunction Panel Meter 1. Introduction : INDEX 2. Features : 3. Model Selection : 4. Specification : 5. Integer Flow : 6. Auxiliary Supply
More informationAPFC-03 AUTOMATIC POWER FACTOR CONTROLLER USER MANUAL. TAS POWERTEK PVT. LTD. VERSION Updated on: 27 th June 2017.
AUTOMATIC POWER FACTOR CONTROLLER APFC-03 USER MANUAL Page 1 of 58 APFC-03/nn Single-CT, Automatic Power Factor Controller for Contactors NOTE These instructions do not purport to cover all details or
More informationJUNXY Series DC Load Banks
JUNXY Series DC Load Banks It is really critical that your standby power system say UPS(uninterrupted power supply), battery bank, AC & DC generator, rectifier, transformers, inverter etc working in good
More informationPower Analyzer Datalogger Model
User's Guide Power Analyzer Model 380801 Power Analyzer Datalogger Model 380803 Extech 380803 Appliance Tester/Power Analyzer Extech 380803 True RMS Power Analyzer Data Logger Extech 380803-NIST True RMS
More informationSafety Instructions 1-1 Avoid unintended Start General Description 2-2
Contents Contents 1 Safety and precautions 1-1 Safety Instructions 1-1 Avoid unintended Start. 1-1 2 Introduction 2-1 General Description 2-2 3 Supported Configuration 3-1 Introduction 3-1 Fixed-speed
More informationINSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:
DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER The DKM-409 is a precision instrument designed for displaying various AC parameters in 3-phase distribution panels. Thanks to its isolated
More informationSymmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers
Symmetra PX 48kW Scalable from 16 to 48kW Modular, Scalable, High-Efficiency Power Protection for Data Centers High performance, right-sized, modular, scalable, 3-phase power protection with high efficiency
More informationUser's Guide. Power Analyzer Model Power Analyzer Datalogger Model Introduction
User's Guide Power Analyzer Model 380801 Power Analyzer Datalogger Model 380803 Introduction Congratulations on your purchase of the Extech 380801 or 380803 Power Analyzer Datalogger. This device offers
More informationPRODUCT. Battery Charger
PRODUCT Battery Charger Model : BC 9080 Battery Charger The ICD Battery Charger is designed to supply required DC Voltage and Current to the connected load and recharge the Battery on boost charging over
More informationManual
Manual 1. Instrument introduction VAC8010F is a multi-function meter based on 2.4 wireless data transmission technology. It can display various physical parameters such as voltage, current, power, capacity,
More informationDKM-407 DIN RAIL TYPE NETWORK ANALYZER
DKM-407 User Manual DKM-407 DIN RAIL TYPE NETWORK ANALYZER DESCRIPTION The DKM-407 is a DIN rail mounted precision and low cost unit allowing measurement and remote monitoring of AC parameters of a distribution
More informationEHS INC. Electric Heating Systems, Inc. 109 North Gold Drive Robbinsville, NJ Phone: (609) Fax: (609)
EHS INC. Electric Heating Systems, Inc. 109 North Gold Drive Robbinsville, NJ 08691 Phone: (609) 259-4116 Fax: (609) 259-4119 6-Way Mobile Transformer Watlow AUTO Controllers Standard Features Are: 73KVA
More information3700 SERIES USER MANUAL
SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with
More informationENERCEPT H8035/H8036 DANGER NOTICE CAUTION. Networked Power Transducer (Modbus RTU) INSTALLATION GUIDE QUICK INSTALL TABLE OF CONTENTS
POWER MONITORING ENERCEPT Networked Power Transducer (Modbus RTU) DANGER US Patent No. 6,373,238 HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in
More informationUser Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter
SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter Measures kwh, Kvarh, KW, Kvar, KVA, PF, Hz, dmd, V, A, etc. Di-directional measurement IMP & EXP Two pulse outputs RS485 Modbus Din rail mounting
More informationEntry Level Assessment Blueprint Electrical Occupations
Entry Level Assessment Blueprint Electrical Occupations Test Code: 3029 / Version: 01 Specific Competencies and Skills Tested in this Assessment: Safety Apply shop safety rules and ergonomics Explain fire
More informationREACTIVE ENERGY REGULATORS
REACTIVE ENERGY REGULATORS computer MAX 6f 12Vdc computer MAX 12f 12Vdc Instruction Manual (M066B01-03-15B) - 1 - Table of Contents 1 INTRODUCTION AND SAFETY TIPS... 3 1.1 CHECKS TO BE CARRIED OUT WHEN
More informationSIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL
SIRIUS 200 U1X200A12-310-SRS U1X200A24-310-SRS USER S MANUAL Belgrade, March 2005 CONTENTS 1 GENERAL 1.1. IMPORTANT NOTICES 2 TECHNICAL SPECIFICATIONS 2.1. INPUT (MAINS) 2.2. OUTPUT 2.3. ENVIROMENTAL CONDITIONS
More informationPGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR Revision 0-C-041918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationPLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet
Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical
More informationEnergy Management Solutions
Energy Management Solutions Power Generation and Transmission Facilities You can provide solution in your Power transmission project with Klea Energy Analyser and Systemon Software Shopping Malls and Chain
More informationNew Solutions. for AC Motor Starters
ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional
More informationEnergy Logger. User's Guide. Model EM Washington Street Melrose, MA Phone Toll Free
User's Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com Energy Logger Model EM100 Introduction Congratulations on your purchase
More informationOPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR
OPERATING MANUAL FOR SMIT-301MH STREAM SELECTOR Manufactured By: INSTRUMENTATION PVT. LTD. F-4 Memnagar complex, Opp. Petrol Pump Memnagar, Ahmedabad, India-380 052 Phone: +91-79_ 2749 5500/5600 FAX: +91-79-2741
More informationLF3-400 Three Phase Frequency Converter, Operation and Maintenance.
Vision House. 41 Brunel Road, Churchfields Industrial Estate, St. Leonards-on-Sea East Sussex. TN38 9RT. United Kingdom Sales & Service : 01424 856 172 magnuspower.sales@akersolutions.com magnuspower.service@akersolutions.com
More informationEHS INC. Electric Heating Systems, Inc. 109 North Gold Drive Robbinsville, NJ Phone: (609) Fax: (609)
EHS INC. Electric Heating Systems, Inc. 109 North Gold Drive Robbinsville, NJ 08691 Phone: (609) 259-4116 Fax: (609) 259-4119 6-Way RAMP Mobile Console Standard Features Are: 50/73/90 KVA Air Natural Transformer
More informationPowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet
PowerLogic power-monitoring units digital panel meters Technical data sheet 2011 Authorized Distributor: WESCHLER INSTRUMENTS phone: 800-903-9870 440-378-6580 fax: 800-903-9590 440-238-0660 www.weschler.com
More informationVorne Industries. Model 77/232 Serial Input Numeric 3" Display User's Manual
Vorne Industries Model 77/232 Serial Input Numeric 3" Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 Page 2 Model 77/232 Serial Input Numeric 3"
More informationLF1-400 Frequency Converter, Operation and Maintenance
Vision House, 41 Brunel Road, Churchfields Industrial Estate, St. Leonards-on-Sea East Sussex. TN38 9RT. United Kingdom Sales & Service : 01424 856 172 magnuspower.sales@akersolutions.com magnuspower.service@akersolutions.com
More informationFM2. Economical and compact feeder protection for low voltage feeders. Digital Energy Multilin. Monitoring & Metering. Protection and Control
Key Benefits FM2 FEEDER Protection System Economical and compact feeder protection for low voltage feeders Comprehensive low voltage feeder management system - Integrated feeder protection and process
More informationMRC350 Card Capture Reader
MRC350 Card Capture Reader INSTALLATION GUIDE REF No.: DOC0071 ISSUE: 1.3 6th Aug 2015 2 Contents MRC350 INSTALLATION GUIDE 1. OVERVIEW 1-1 1.1 Card Types and Controller Interfaces 1-1 1.2 Basic Operation
More informationPower Factor Controller BR604
Power Factor Controller BR604 Series/Type: BR604 Ordering code: Date: December 2006 Version: 2 Content of inside pages of data sheet. Data will be automatically entered into frontpage headlines, headers
More informationANALIZZATORE DI RETE TRIFASE 90A
ANALIZZATORE DI RETE TRIFASE 90A ADR-D 400 D90 Manuale d Uso User Manual THREE-PHASE NETWORK ANALYSER 90A Table of contents Safety instructions pag. 16 Technical specifications pag. 17 Description pag.
More informationLEVELUPS T3 3 UPS. SERIES kva ONLINE UPS 3:3 PHASE VFI TYPE. Highest Reliability with Embedded Isolation Transformer
LEVELUPS T SERIES DATA CENTER MEDICAL TRANSPORT INDUSTRY EMERGENCY Three LEVEL UPS VFI TYPE PF=.0 Service UPS ONLINE TOWER POWER FACTOR SERVICE HIGHLIGHTS True Three Level Rectifier and Inverter Technology
More informationDIRIS N300/N600 Network analysers Network quality control and analysis system
Metering, monitoring & power quality Function DIRIS_755_a_1_cat DIRIS_762_a_1_gb_cat DIRIS N300 / N600 are multifunction network analysers designed for in-depth analysis of electrical networks in order
More informationPOWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual IM2493WVP-3
POWER SERIES Plus Watt / VAR / Power Factor Digital Switchboard Meter User s Manual General Description The POWER SERIES Plus digital switchboard meters incorporate the latest DSP microprocessor technology.
More informationEM6400 series Multi-Function meters
6400 series Multi-Function meters 1 Digital display & Analog load bar indicators 2 Bright Red LED display 3 Global: CE, UL marks 4 Universal Demand Monitoring Quick and easy installation Turbo Key 6400
More informationEM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters
Power and Energy Meters Code No. LIT-1900845 Issued December 4, 2013 EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters EM-1000 Series Meter Description The EM-1000 Series monitor is
More informationVoltage Sag Simulator
For use with all DPI s & VDC s 120/208/240V 50/60Hz LEADERS IN VOLTAGE-DIP PROOFING Contents Introduction to the DPI... 3 Theory of DPI operation... 3 Description -... 4 Operation... 5 Sag Simulation...
More informationVLT Line Filter MCC 107 EMC Filter Series VLT Midi Drive FC 280 (K1 K3)
These instructions provide technical and installation information for the MCC 107 EMC filter series. Only Danfoss qualified personnel is allowed to install this equipment. The personnel must be familiar
More informationQuick Start Installation and User Manual
1 Quick Start Installation and User Manual Contents 1. Overview 2. Technical Specifications 3. Installation Mounting Electrical Installation Clamp Installation Wiring Diagrams 4. Installation Settings
More informationInnovations in the Sirius Modular System for greater efficiency in Industrial Controls and in control cabinet construction
Eckard Eberle, Head of the Control Components Business Segment Siemens AG, Nuremberg International Trade Press Conference held on 24 November 2009 in Nuremberg Innovations in the Sirius Modular System
More informationPowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006
PowerLogic power-monitoring units Technical data sheet 2006 Functions and characteristics E90463 The PowerLogic PM500 Power Meter provides all measurement capabilities required to monitor an electrical
More informationNewCode. Comprehensive Motor Protection and Control Relay. Relay Field Input and Output LEDs. LED Fault Indicators
NewCode Comprehensive Motor Protection and Control Relay Relay Field Input and Output LEDs LED Fault Indicators Configurable Memory Module on a T-Bus IrDA and USB Connectors Profibus Address Indicator
More informationIMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS
IMPORTANT SAFETY INSTRUCTIONS IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS WARNING (SAVE THESE INSTRUCTIONS): This manual contains important instructions that should be followed during installation
More informationDPM Active Harmonic Filter Quick Start Instructions
DPM Active Harmonic Filter Quick Start Instructions These instructions will guide you through installing, testing your installation, and starting up your DPM. For additional information please refer to
More information