1 Quick Reference Datasheet For All RIT113 Packages For Rotational Therapies, IMRT & TG142 Highlights and selected product information only. A complete TG142 brochure is available. For more information on this, other analysis routines, and image capture options visit radimage.com or call , is our original version. It includes all the patient and machine QA routines that we have developed to help the medical physicist perform all the analysis requirements they may ever need to perform. RITG142, is just what you need, to meet all and only those tests recommended in TG142. RIT Complete is a combination of RIT113 Classic, and Radia Therapy in one convenient package. Cut Out The Middle Machine Use Your EPID For QA

2 Recently Added Some analysis routines, functions and features recently added to RIT113 - for more details on each, visit radimage.com Packages Performs or trends EVERY test in TG142. See our TG142 Datasheet for complete information and package options. Statistical Trend Database RITtrend is much more than a statistical database. You easily set your own specifications and then automatically analyze process control limits on RIT113 analyzed equipment, knowing when and where to make changes in your system to reduce its overall variability. The new Multi Source Data Manager gives you even more control for reporting on your entire Medical Physics program. It s customizable format allows you to add analysis data from any and all equipment used in your Medical Physics program, including non RIT113 analyzed data. It redefines database recording into a major tool for analysis and recordkeeping in your department. Static and Dynamic MLC Elekta Jaw Setback Test Elekta Leaf Position Test Improved Picket Fence Tests Image Capture Image Compositor Great new GUI interface for easily making composite images. Add together images for use in MLC QA, Stereotactic QA, and large field IMRT analysis. Primarily used for EPID images but can be used on all image types. This routine also supports a number of other operations: Add, subtract, multiply, divide, and other operations including scaling. EPID Importing EPID Images for QA Use your Elekta, Varian or Siemens EPID for QA with a seamless interface that does not require additional manufacturer hardware and software. Quickly and easily composite EPID images into RIT format using the new Image Compositor. EPID Calibration RIT s patented Plan Based Calibration routine gives you the ability to make quick relative comparisons between any dose map and your EPID, FILM or CR. Elekta iview Calibration Varian as Calibration Scale DICOM images from Varian EPIDs Some Varian EPID images may contain scaling information to restore dose information. If this featured is enabled (in preferences) the Varian as Portal Image Interface will detect these parameters and restore the EPID image. An optional scaling factor may also be applied. 2

3 2D Detector Arrays Import From 2D Arrays Ion Chamber arrays from IBA and PTW and MapCheck diode arrays are supported. IMRT analysis routines have been revised to handle sparse data. Results can be saved as an RIT Array Case file. PTW seven29 Direct Interface This interface operates similarly to our direct interface to your film scanner. It simplifies temperature and pressure value entry, making them very quick and easy. Then, the image is automatically imported into RIT113 for analysis. Film Dosimetry for QA Radiochromic and Radiographic Film with Vidar and Flatbed Scanners EBT2 and Flatbed Scanner Correction Corrects EBT film scanned on a flatbed scanner for: Red/Blue channel correction AND scanner flatness and uniformity. A dose calibration file is also created all from one image set. Utilizes RIT s patented Plan Based Calibration to develop optimized calibration curves. (Available for international customers only. Not available in the USA.) Radiochromic Film Uniformity Correction Automated 21 Point Film Processor Correction Sensitometry 2D Scanner Spatial Calibration (Vidar and Flatbed Scanners) Direct interface with all Vidar Dosimetry scanners Generic Image File Import Importing generic JPEG, TIFF and Bitmap image files from sources other than your Vidar Scanner gives you increased flexibility in your workflow to use RIT s exclusive analysis routines. Perfect for Cyperknife analysis! Vidar Advantage Pro 180 Correction For use on Advantage Pro RED units only: Corrects for sloping profile from left side to center; Works with film up to 10 wide and Improves flatness by a factor of 2 to 4. Improved Vidar Scanner Interface (Vidar Scanner Control Center) Allows for multiple film scanning, auto-naming, and autocropping, auto-flipping, and preview of scanned images CR 3D CR Flatness & Uniformity Correction Kodak CR Perpendicular Calibration Kodak CR Spatial Calibration 3D Gels and Solids Are Supported 3

4 Automated Batch Analysis Fully automated registration control point positioning in both traditional and RunQueueA IMRT analysis. Automated matching and sorting of reference and target images along with thumbnail of all images simultaneously Extended options for output storage to reference or target image file path ROI Trim Option RITtrend TM Statistical Trend Database RITtrend is much more than a statistical database. You easily set your own specifications and then automatically analyze process control limits on RIT113 analyzed equipment, knowing when and where to make changes in your system to reduce its overall variability. The new Multi Source Data Manager gives you even more control for reporting on your entire Medical Physics program. It s customizable format allows you to add analysis data from any and all equipment used in your Medical Physics program, including non RIT113 analyzed data. It redefines database recording into a major tool for analysis and recordkeeping in your department. IMRT, IGRT & RapidArc/VMAT Analysis Gamma Function Using the Classical Gamma Analysis method by Low, et. al. Using the new Digital Gamma Plot in the IMRT measurements menus, this algorithm is based on A quantitative evaluation of IMRT dose distributions: refinement and clinical assessment of the gamma evaluation, Dupuydt et al., Radiotherapy and Oncology 62 (2002) Using the optional algorithm accessible in the preference settings of RIT, this algorithm is proposed in Geometric interpretation of the dose distribution comparison technique: Interpolation-free calculation, Ju et al., Medical Physics, Vol. 35, No. 3, March Distance To Agreement Water Tank Beam Measurement Analysis Profiles Van Dyk's Analysis Subtraction Composite Analysis Isodose Curves Addition IGRT Alignment Used to measure the spatial misalignment between the IGRT imaging system and the treatment beam Register Template IMRT Automatic Fine Tune Registration 4

5 3D QA Phantom Bilinear Interpolation & Non-cropping Rotation Import from 2D Detector Arrays Ion Chamber arrays from IBA and PTW and MapCheck diode arrays are supported. IMRT analysis routines have been revised to handle sparse data. Results can be saved to a RIT Array Case file. Automated Registration Fully automated registration control point positioning in both traditional and RunQueueA IMRT sumultaneously. Brainlab Flip images as they are imported Automated matching of Images RunQueueA features automated matching and sorting of reference and target images along with thumbnails of all images simultaneously. Improved initial positioning of acquired image points when using template registration. Extended options for output storage location in RunQueueA scripts to either the reference or target image file path. New ROI option trim in RunQueueA Allows the user to specify a trim dimension from each edge of the images New IMRT analysis plot called Proportion Passing Plots the proportion passing for a range of subtraction tolerances Case files can be saved from IMRT analysis toolbars. It is not necessary to use RunQueueA to make a Case file. Send IMRT results to other RIT users or Tech Support. Save and Restore all IMRT Analysis Layouts Use arrow keys to move Profiles in IMRT and other beam measurements. Auto-increment registration points to eliminate registration errors. Improved Normalization Improved Fine Tune Registration TomoTherapy Beam Planarity and Jaw Twist Overhead Laser Import Calibration files Import Tomo "DICOM" files 5

6 Static and Dynamic MLC Generic Picket Fence Generic picket fence images may have any number of pickets and at any spacing as long as they are regular. Improved MLC analysis (includes Bayouth test) MLC images do not need to be calibrated, may be any size, and will be referenced back to 100 SSD. You will now enter the SSD with each image. Automated Analysis of Varian RapidArc Tests Images may be of any size (from up in the accelerator head to down on the floor). EPID, Film, or CR images may be used and tests and comparison at multiple gantry angles are supported. Bayouth MLC Analysis Memorial Sloan Kettering Test Pattern MLC Transmission Analysis (TG50 Recommended) 50% Fluence Analysis (TG50 Recommended) Improved picket fence tests Elekta Jaw Setback Test Elekta Leaf Position Test Varian DMLC Test Patterns Analysis Ability to import Elekta.HIS files Dose Calibration Daily Output Factor Adjustment Calibration Data Point Highlighter Plan Based Calibration (US Patents , , CA Patent , International Patents Pending) The ability to make quick relative comparisons between any dose map and your Film, Array, and CR images. MLC Calibration Technique (US Patents , , International Patents Pending) 2D Scanner Spatial Calibration for both Vidar and Flatbed Scanners Perpendicular Dose Calibration Varian as Calibration iview Calibration Parallel Dose Calibration Kodak CR Perpendicular Calibration Kodak Spatial Calibration PDD Table Editor 6

7 EBT2 and Flatbed Scanner Correction Plus Calibration Corrects EBT film scanned on a flatbed scanner for Red/Blue channel correction AND scanner flatness and uniformity. A dose calibration file is also created all from one image set. It utilizes RIT s patented Plan Based Calibration to develop optimized calibration curves. (Available for international customers only. Not available in the USA.) Stereotactic Analysis Stereotactic Cone Profiles Stereotactic Alignment Star Shot and Stereotactic images may be analyzed without applying a calibration file. Use EPIDs to acquire Winston Lutz images. Using the RIT Image Compositor they can be analyzed in one test on a composite image. Beam Measurements Cyberknife Alignment Improved alignment routine for low contrast cones. Star Shot Analysis Star Shot and Stereotactic images may be analyzed without applying a calibration file. Performing MLC Starshot test using the RIT Image Compositor to make MLC starshot patterns. Radiation/Light Field Coincidence Radiation/Light Field EPID images may be analyzed without applying a calibration file. You can also have custom field sizes, not just 5, 10, 15, and 20 cm., and take a BB or pin prick for center location. Asymmetric Field/Matchline Depth Dose Cross Sections 3D Dose Profiles Electron Energy Quick Flatness & Symmetry Isodose Contours Cross Profiles Enhancements Indicator lines added to profile plots to indicate location of opposite profile; Ability to lock the intersection; Moveable profile bar; FWHM measurements reported for each side of the profile. Useful for MLC tests on jaw positions on Elekta machines and for Gamma Knife commissioning. Monitor Calibration with TG18 and SMPTE Brainlab Flip images as they are imported 7

8 Therapy Routines Included in RIT113 Complete and Radia Base plus KV Imager routines DISC Plus IBA Primus L PTW Normi-4 Leeds TOR 18FG ISO Cube Radia Base plus MV Imager routines PTW Las Vegas QC-3 Siemens ISO Cube Radia Base plus CBCT Imager Catphan Elekta XVI ISO Cube Radia Base plus Electron Density (optional add-in) A Gammex Cheese Visit Call sales@radimage.com Radiological Imaging Technology, Inc., July,

RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package.

RITtrend allows you to effectively manage all your physics QA data in one powerful and customizable package. So much is asked of medical physicists these days We Can Help Automated Radiation Therapy Phantom Analysis in Seconds QC for Therapy OBI s and CT simulators. Radia s Catphan/OBI module performs analysis

More information

Raising the Bar in IMRT QA

Raising the Bar in IMRT QA MapCHECK 2TM Raising the Bar in IMRT QA The leader in quick and precise measurement of modulated radiotherapy beams Benefits Proven solution for film-less rotational delivery and IMRT QA - More than 1500

More information

Version 5.6. Quick Start Guide

Version 5.6. Quick Start Guide WWW..COM Version 5.6 Quick Start Guide STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 Jul / 2018 2018 Standard Imaging, Inc. TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 DOC # 80714-05

More information

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH. The Gold Standard for 2D Arrays MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays Your Most Valuable QA and Dosimetry Tools THE GOLD STANDARD FOR 2D ARRAYS The MapCHECK 2 is the world s most selected independent 2D measurement array.

More information

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays

MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays MapCHECK 2 & 3DVH The Gold Standard for 2D Arrays Your Most Valuable QA and Dosimetry Tools THE GOLD STANDARD FOR 2D ARRAYS The MapCHECK 2 is the world s most selected independent 2D measurement array.

More information

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

Facility Questionnaire PART I (General Information for 3DCRT and IMRT) Facility Questionnaire PART I (General Information for 3DCRT and IMRT) The following items are required before you can enter cases on any RTOG protocol that requires data submission to the Image-Guided

More information

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac

More information

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004

Qalitätssicherung an Multileafkollimatoren. Dr. Lutz Müller Würzburg jan 2004 Qalitätssicherung an Multileafkollimatoren Dr. Lutz Müller Würzburg jan 2004 IMRT Verification - present Target Volume Constraints Inverse Planning Algorithm Fluence Map Leaf Sequencer Leaf & Gantry sequence

More information

Table of Contents. About AQUA

Table of Contents. About AQUA User Manual About AQUA Table of Contents 1 About AQUA... 6 1.1 Radiation Therapy... 6 1.1.1 Workflow manager... 6 1.1.2 Reports... 7 1.1.3 Tests... 7 1.1.4 Many Ways to Work... 7 1.2 Technology... 7 1.3

More information

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center

Comparison of Two Phantoms for End-to-End SRS/SBRT Testing. Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center Comparison of Two Phantoms for End-to-End SRS/SBRT Testing Vikren Sarkar, Ph.D. Associate Professor University of Utah Huntsman Cancer Center Disclosure Travel and Speaker Honorarium from Sun Nuclear Corp.

More information

FAST, precise. qa software

FAST, precise. qa software qa software FAST, precise Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, rotational or brachytherapy plans no film, no phantoms, no linac

More information

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays

IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays IMRT and VMAT Patient Specific QA Using 2D and 3D Detector Arrays Sotiri Stathakis Outline Why IMRT/VMAT QA AAPM TG218 UPDATE Tolerance Limits and Methodologies for IMRT Verification QA Common sources

More information

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS Tomotherapy Physics Machine Twinning and Quality Assurance Emilie Soisson, MS Tomotherapy at UW- Madison Treating for nearly 5 years Up to ~45 patients a day on 2 tomo units Units twinned to facilitate

More information

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions

Disclosure. Outline. Acknowledgments. Ping Xia, Ph.D., Page 1. LINAC and MLC QA for IMRT. Received research support from Siemens Medical Solutions LINAC and MLC QA for IMRT Ping Xia, Ph.D., Department of Radiation Oncology Disclosure Received research support from Siemens Medical Solutions University of California San Francisco Therapy Series (SAM)

More information

DAILY LINAC QA BEAM QA

DAILY LINAC QA BEAM QA BEAM QA DAILY LINAC QA The QA BeamChecker Plus allows for fast, reliable, and uncomplicated daily QA of Varian, Elekta, Siemens, and Accuray Treatment Machines. The QA BeamChecker Plus is specifically

More information

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending

3DVH : SUN NUCLEAR On The Accuracy Of The corporation Planned Dose Perturbation Algorithm Your Most Valuable QA and Dosimetry Tools *Patent Pending 3DVH : On The Accuracy Of The Planned Dose Perturbation Algorithm SUN NUCLEAR corporation Your Most Valuable QA and Dosimetry Tools *Patent Pending introduction State-of-the-art IMRT QA of static gantry

More information

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT

Volumetric Modulated Arc Therapy - Clinical Implementation. Outline. Acknowledgement. History of VMAT. IMAT Basics of IMAT Volumetric Modulated Arc Therapy - Clinical Implementation Daliang Cao, PhD, DABR Swedish Cancer Institute, Seattle, WA Acknowledgement David M. Shepard, Ph.D. Muhammad K. N. Afghan, Ph.D. Fan Chen, Ph.D.

More information

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA

8/2/2017. PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA PerFRACTION from Sun Nuclear Automated Transit Dosimetry for In-Vivo QA Jennifer R. Clark, M.S., DABR Conflict of Interest Statement: I am an employee of Sun Nuclear Corporation Outline: Platform overview

More information

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³ Technical Note D655.208.03/00 Code of practice: Create a verification plan for OCTAVIUS Detector 729 in There are basically three ways to carry out verification of IMRT fluences. For all options, it is

More information

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1

4 Measurement. and Analysis. 4.1 Overview and Underlying Principles 4-1 Measurement and Analysis.1 Overview and Underlying Principles.1.1 Introductory Remarks The physics and setup for film dosimetry have been described in the previous chapters. The measurement setup for IMRT

More information

Automated Quality Assurance for Image-Guided Radiation Therapy

Automated Quality Assurance for Image-Guided Radiation Therapy JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 10, NUMBER 1, WINTER 2009 Automated Quality Assurance for Image-Guided Radiation Therapy Eduard Schreibmann, a Eric Elder, Tim Fox Department of Radiation

More information

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws.

Preface. Med. Phys. 35(9), , Mechanical QA. Radiation Survey Mechanical tests Light radiation Table, Collimator, Gantry Jaws. AAPM-SAM-2012-Das (1) Beam Data Collection and Commissioning for Linear Accelerators: Technical Considerations and Recommendations Preface Indra J. Das, PhD, FAAPM, FACR, FASTRO Department of Radiation

More information

A comparative analysis for verification of IMRT and VMAT treatment plans using a 2-D and 3-D diode array

A comparative analysis for verification of IMRT and VMAT treatment plans using a 2-D and 3-D diode array The University of Toledo The University of Toledo Digital Repository Theses and Dissertations 2014 A comparative analysis for verification of IMRT and VMAT treatment plans using a 2-D and 3-D diode array

More information

Advanced Radiotherapy

Advanced Radiotherapy Advanced Radiotherapy IBA Concept for IMRT Verification Dr. Lutz Müller 1 IMRT Verification BIS BIS ADAS Fluence Model Delivered fluence Target Volume Constraints Inverse Backprojection Fluence Map Leaf

More information

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER!

THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER! THE WIRELESS PHANTOM PERFORM ACCURATE PATIENT QA IN LESS TIME THAN EVER! Confidence in complex treatments Modern radiation therapy uses complex plans with techniques such as IMRT, VMAT and Tomotherapy.

More information

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems Bruce Curran University of Michigan Medical Center Ann Arbor, MI Disclosure Some of the work discussed in this talk was supported

More information

Machine and Physics Data Guide

Machine and Physics Data Guide WWW..COM Machine and Physics Data Guide STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 May / 2008 2008 Standard Imaging, Inc. TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 www.standardimaging.com

More information

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear

Delta 4 PT. True Volumetric Pre-treatment Verification. The difference is clear Delta 4 PT True Volumetric Pre-treatment Verification The difference is clear ScandiDos innovators in advanced volumetric dosimetry solutions ScandiDos ScandiDos is the innovative company that introduced

More information

TG-148 overview. Introduction. System Overview. System Overview. QA for Helical Tomotherapy: Report of the AAPM Task Group 148. Conflict of Interest:

TG-148 overview. Introduction. System Overview. System Overview. QA for Helical Tomotherapy: Report of the AAPM Task Group 148. Conflict of Interest: QA or Helical Tomotherapy: Report o the AAPM Tas Group 148 Members: Conlict o Interest: r. John Balog owns TomoTherapy stoc. Katja Langen (Co-chair) Nio Papaniolaou (Co-chair) Walter Grant Richard Crilly

More information

Introduction. Quality Assurance for Image- Guided Radiation Therapy. Justification for IGRT. Image-Guided Radiation Therapy

Introduction. Quality Assurance for Image- Guided Radiation Therapy. Justification for IGRT. Image-Guided Radiation Therapy Introduction Quality Assurance for Image- Guided Radiation Therapy Jean-Pierre Bissonnette, Ph.D., MCCPM Princess Margaret Hospital, Toronto, Canada IGRT What is it? Rationale Equipment Quality Assurance

More information

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing

ImPACT. Information Leaflet No. 1: CT Scanner Acceptance Testing ImPACT Information Leaflet No. 1: CT Scanner Acceptance Testing Version 1.02, 18/05/01 CONTENTS: 1. SCOPE OF LEAFLET 2. GENERAL PRINCIPLES OF ACCEPTANCE AND COMMISSIONING 2.1 PHANTOMS 2.2 EXPOSURE AND

More information

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles

Use of a commercial ion chamber detector array for the measurement of high spatial resolution photon beam profiles Received: 17 January 2018 Revised: 27 August 2018 Accepted: 31 August 2018 DOI: 10.1002/acm2.12466 TECHNICAL NOTE Use of a commercial ion chamber detector array for the measurement of high spatial resolution

More information

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques

IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques IAEA-TECDOC-1583 Commissioning of Radiotherapy Treatment Planning Systems: Testing for Typical External Beam Treatment Techniques Report of the Coordinated Research Project (CRP) on Development of Procedures

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT The RayPlan treatment planning system makes proven, innovative RayStation technology accessible to clinics that need a cost-effective and streamlined solution. Fast, efficient and straightforward to use,

More information

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1

TPS COMMISSIONING. Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1 TPS COMMISSIONING Laurence Court University of Texas MD Anderson Cancer Center 4/3/2017 1 Conflicts of interest Court receives funding from NIH, CPIRT, Varian and Elekta 4/3/2017 2 Resources your first

More information

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT CLINICAL COMMISSIONING AND ACCEPTANCE TESTING OF A 3D SURFACE MATCHING SYSTEM Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago Learning Objective Describe acceptance

More information

GafChromic Protocol Multi-Channel Film Dosimetry + Gamma Map Analysis

GafChromic Protocol Multi-Channel Film Dosimetry + Gamma Map Analysis GafChromic Protocol Multi-Channel Film Dosimetry + Gamma Map Analysis Micke A. Ashland Inc. Advanced Materials Ashland proprietary patented technology GafChromic Film for Dose Measurement Radiotherapy

More information

Feasibility study of performing IGRT system daily QA using a commercial QA device

Feasibility study of performing IGRT system daily QA using a commercial QA device JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 12, NUMBER 3, summer 2011 Feasibility study of performing IGRT system daily QA using a commercial QA device Jean L.Peng, 1 Darren Kahler, 2 Jonathan

More information

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences)

Goals. Scope/exclusions. Outline: follow outline of MPPG (plus rationale & some implementation experiences) AAPM MEDICAL PHYSICS PRACTICE GUIDELINE # : Commissioning and QA of Treatment Planning Dose Calculations: Megavoltage Photon and Electron Beams Jennifer Smilowitz (Chair), University of Wisconsin-Madison

More information

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface

A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface A Geant4 based treatment plan verification tool: commissioning of the LINAC model and DICOM-RT interface Iwan Cornelius, Chris Poole. Stephen Warwick, Christian Langton Discipline of Physics, Faculty of

More information

Initial Clinical Experience with 3D Surface Image Guidance

Initial Clinical Experience with 3D Surface Image Guidance Initial Clinical Experience with 3D Surface Image Guidance Amanda Havnen-Smith, Ph.D. Minneapolis Radiation Oncology Ridges Radiation Therapy Center Burnsville, MN April 20 th, 2012 Non-funded research

More information

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF Page 1 Quality Assurance of IMRT Delivery Systems - Siemens Lynn J. Verhey, Ph.D. Professor and Vice-Chair UCSF Dept. of Radiation Oncology AAPM 22 Annual Meeting, Montreal Acknowledgments Ping Xia, Ph.D.,

More information

Dynalog data tool for IMRT plan verification

Dynalog data tool for IMRT plan verification Dynalog data tool for IMRT plan verification Poster No.: R-0051 Congress: 2014 CSM Type: Scientific Exhibit Authors: V. Sashin; FOOTSCRAY/AU Keywords: Computer applications, Radiation physics, Experimental,

More information

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

URGENT IMPORTANT FIELD SAFETY NOTIFICATION Subject: Incorrect Movement of the Treatment Table Product: MOSAIQ Scope: Sites affected will be those: 1. Running MOSAIQ and, 2. Treating on linear accelerators with the RATM license Notification Released:

More information

Virtual Phantoms for IGRT QA

Virtual Phantoms for IGRT QA TM Virtual Phantoms for IGRT QA Why ImSimQA? ImSimQA was developed to overcome the limitations of physical phantoms for testing modern medical imaging and radiation therapy software systems, when there

More information

Feasibility of 3D Printed Patient specific Phantoms for IMRT QA and Other Dosimetric Special Procedures

Feasibility of 3D Printed Patient specific Phantoms for IMRT QA and Other Dosimetric Special Procedures Feasibility of 3D Printed Patient specific Phantoms for IMRT QA and Other Dosimetric Special Procedures ehler 046@umn.edu Eric Ehler, PhD Assistant Professor Department of Radiation Oncology What is 3D

More information

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code

Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code American Journal of Biomedical Engineering 216, 6(4): 124-131 DOI: 1.5923/j.ajbe.21664.3 Analysis of Radiation Transport through Multileaf Collimators Using BEAMnrc Code Ankit Kajaria 1,*, Neeraj Sharma

More information

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon

Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon Design and performance characteristics of a Cone Beam CT system for Leksell Gamma Knife Icon WHITE PAPER Introduction Introducing an image guidance system based on Cone Beam CT (CBCT) and a mask immobilization

More information

ph fax Deming Way Middleton WI USA

ph fax Deming Way Middleton WI USA www.standardimaging.com 800-261-4446. ph 608-831-0025. fax 608-831-2202 3120 Deming Way Middleton WI 53562-1461 USA 2007 Standard Imaging, Inc. 1239-21 (03.07) beam qa LINAC AND TOMOTHERAPY QA The NEW

More information

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon WHITE PAPER Introduction An image guidance system based on Cone Beam CT (CBCT) is included in Leksell

More information

Calibration and quality assurance for rounded leaf-end MLC systems

Calibration and quality assurance for rounded leaf-end MLC systems Calibration and quality assurance for rounded leaf-end MLC systems Maria N. Graves, a) Antoinette V. Thompson, b) Mary K. Martel, Daniel L. McShan, and Benedick A. Fraass Department of Radiation Oncology,

More information

Use of TrueBeam developer mode for imaging QA

Use of TrueBeam developer mode for imaging QA JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 4, 2015 Use of TrueBeam developer mode for imaging QA Gilmer Valdes, 1,2a Olivier Morin, 1 Yanisley Valenciaga, 3 Niel Kirby, 1 Jean Pouliot,

More information

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator

Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Automated Image Analysis Software for Quality Assurance of a Radiotherapy CT Simulator Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer Centre Western General Hospital EDINBURGH EH4

More information

DoseLab for TomoTherapy. AAPM Task Group 148 Background

DoseLab for TomoTherapy. AAPM Task Group 148 Background DoseLab for TomoTherapy Performing TG-148 QA with DoseLab Christine Gnaster, MS, DABR DoseLab Product Manager AAPM Task Group 148 Background TG-148 could be likened to the TG-142 for TomoTherapy machines

More information

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems

Evaluation of 3D Gamma index calculation implemented in two commercial dosimetry systems University of Wollongong Research Online Faculty of Engineering and Information Sciences - Papers: Part A Faculty of Engineering and Information Sciences 2015 Evaluation of 3D Gamma index calculation implemented

More information

Future is Effortless

Future is Effortless AQUATM Radiology is a machine Quality Assurance management solution that standardizes, streamlines and automates QA procedures throughout rediology department and across multiple sites. AQUATM Radiology

More information

Real-time monitoring of linac performance using RT plans and logfiles

Real-time monitoring of linac performance using RT plans and logfiles Real-time monitoring of linac performance using RT plans and logfiles NCCAAPM Wisconsin Dells 7 April 2017 Mark Wiesmeyer, PhD, DABR Technical Product Manager Technical talk with insights and results based

More information

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS

NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS NEW METHOD OF COLLECTING OUTPUT FACTORS FOR COMMISSIONING LINEAR ACCELERATORS WITH SPECIAL EMPHASIS ON SMALL FIELDS AND INTENSITY MODULATED RADIATION THERAPY by Cindy D. Smith A Thesis Submitted to the

More information

Photon beam dose distributions in 2D

Photon beam dose distributions in 2D Photon beam dose distributions in 2D Sastry Vedam PhD DABR Introduction to Medical Physics III: Therapy Spring 2014 Acknowledgments! Narayan Sahoo PhD! Richard G Lane (Late) PhD 1 Overview! Evaluation

More information

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them

Dose Distributions. Purpose. Isodose distributions. To familiarize the resident with dose distributions and the factors that affect them Dose Distributions George Starkschall, Ph.D. Department of Radiation Physics U.T. M.D. Anderson Cancer Center Purpose To familiarize the resident with dose distributions and the factors that affect them

More information

VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning. Rajat Kudchadker, Ph.D. Associate Professor

VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning. Rajat Kudchadker, Ph.D. Associate Professor VMAT for dummies: Concepts, Clinical Implementation and Treatment Planning Rajat Kudchadker, Ph.D Associate Professor 2012 AAPM Spring Clinical Meeting Disclaimer I hold no financial interest nor have

More information

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL

A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL A DOSIMETRIC MODEL FOR SMALL-FIELD ELECTRON RADIATION THERAPY A CREATIVE PROJECT (3 SEMESTER HOURS) SUBMITTED TO THE GRADUATE SCHOOL IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE DEGREE MASTER OF

More information

Protocol. Technical evaluation of X-ray tomographic image-guided radiotherapy devices CEP10070

Protocol. Technical evaluation of X-ray tomographic image-guided radiotherapy devices CEP10070 Protocol Technical evaluation of X-ray tomographic image-guided radiotherapy devices CEP10070 March 2010 Contents 2 Introduction... 3 Protocol design and validation... 4 General information... 7 Technical

More information

Evaluation report. X-ray tomographic image guided radiotherapy systems CEP10071

Evaluation report. X-ray tomographic image guided radiotherapy systems CEP10071 Evaluation report X-ray tomographic image guided radiotherapy systems CEP10071 March 2010 Contents 2 Summary... 3 Introduction... 6 Product description... 9 Methods... 14 Technical performance... 23 Purchasing...

More information

ADVANCING CANCER TREATMENT

ADVANCING CANCER TREATMENT 3 ADVANCING CANCER TREATMENT SUPPORTING CLINICS WORLDWIDE RaySearch is advancing cancer treatment through pioneering software. We believe software has un limited potential, and that it is now the driving

More information

C a t p h a n / T h e P h a n t o m L a b o r a t o r y

C a t p h a n / T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 T h e P h a n t o m L a b o r a t o r y C a t p h a n 5 0 0 / 6 0 0 Internationally recognized for measuring the maximum obtainable performance of axial, spiral and multi-slice

More information

1. Learn to incorporate QA for surface imaging

1. Learn to incorporate QA for surface imaging Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** 1. Learn to incorporate QA for surface imaging into current QA procedures for IGRT. 2. Understand

More information

Clinical implementation of photon beam flatness measurements to verify beam quality

Clinical implementation of photon beam flatness measurements to verify beam quality JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 16, NUMBER 6, 2015 Clinical implementation of photon beam flatness measurements to verify beam quality Simon Goodall, a Nicholas Harding, Jake Simpson,

More information

The Jacobian as a measure of planar dose congruence

The Jacobian as a measure of planar dose congruence The Jacobian as a measure of planar dose congruence L. D.Paniak 1 and P. M. Charland 2 1 4 Solutions Inc, Kitchener, Ontario 2 Grand River Hospital, Kitchener, Ontario and the University of Waterloo, Waterloo,

More information

3DVH FAQs. What is PDP questions

3DVH FAQs. What is PDP questions 3DVH FAQs What is PDP questions 1. Explain the PDP in layman terms. How does PDP work? a. Very simply, PDP uses measured diode data, and compares it to the expected treatment plan data. The differences

More information

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC New Technology in Radiation Oncology James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC Technology s s everywhere From the imaging chain To the planning system To the linac To QA..it..it

More information

2D DOSE MEASUREMENT USING A FLAT PANEL EPID

2D DOSE MEASUREMENT USING A FLAT PANEL EPID 2D DOSE MEASUREMENT USING A FLAT PANEL EPID by Seng Boh Lim B.A.Sc. (Hons.), University of British Columbia, 1994 M.A.Sc., University of British Colombia, 1996 M.Eng, University of British Columbia, 2002

More information

Basic Radiation Oncology Physics

Basic Radiation Oncology Physics Basic Radiation Oncology Physics T. Ganesh, Ph.D., DABR Chief Medical Physicist Fortis Memorial Research Institute Gurgaon Acknowledgment: I gratefully acknowledge the IAEA resources of teaching slides

More information

Quality assurance of a helical tomotherapy machine

Quality assurance of a helical tomotherapy machine INSTITUTE OF PHYSICS PUBLISHING Phys. Med. Biol. 49 (2004) 2933 2953 PHYSICS IN MEDICINE AND BIOLOGY PII: S0031-9155(04)71892-8 Quality assurance of a helical tomotherapy machine J D Fenwick 1,2,WATomé

More information

Evaluation of AutoQA Lite TM Image Quality Measurement Software

Evaluation of AutoQA Lite TM Image Quality Measurement Software Evaluation of AutoQA Lite TM Image Quality Measurement Software Andrew J Reilly Imaging Physicist Oncology Physics Edinburgh Cancer Centre Western General Hospital EDINBURGH EH4 2XU Phone: 0131 537 1161

More information

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers

Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Investigation of tilted dose kernels for portal dose prediction in a-si electronic portal imagers Krista Chytyk MSc student Supervisor: Dr. Boyd McCurdy Introduction The objective of cancer radiotherapy

More information

Commissioning, beam matching and small field dosimetry experience with Elekta Versa

Commissioning, beam matching and small field dosimetry experience with Elekta Versa Commissioning, beam matching and small field dosimetry experience with Elekta Versa Raj Varadhan, PhD Director of Physics, Technology Minneapolis Radiation Oncology Outline Elekta Versa/Infinity platform

More information

A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems

A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems A novel-integrated quality assurance phantom for radiographic and nonradiographic radiotherapy localization and positioning systems Amy S. Yu a) Tyler L. Fowler, and Piotr Dubrowski Department of Radiation

More information

Follow this and additional works at:

Follow this and additional works at: The University of Toledo The University of Toledo Digital Repository Theses and Dissertations 2010 Implementation of the Dosimetry Check software package in computing 3D patient exit dose through generation

More information

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta

Use of Monte Carlo modelling in radiotherapy linac design. David Roberts, PhD Senior Physicist Elekta Use of Monte Carlo modelling in radiotherapy linac design David Roberts, PhD Senior Physicist Elekta Contents Overview of Elekta What we do Where we use Monte Carlo Codes and resources Example : Agility

More information

3D Scanning Comes Full Circle

3D Scanning Comes Full Circle 3D SCANNER TM 3D Scanning Comes Full Circle Relative 3D Dosimetry offering the easiest setup, most objectivity, and best consistency available Cross-Plane Advanced Design Ring and diameter drive mechanism

More information

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 ICARO Vienna April 27-29 2009 Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 M. Saiful Huq, Ph.D., Professor and Director, Dept. of Radiation

More information

A NEW LASER FOCUS ON PATIENT SAFETY

A NEW LASER FOCUS ON PATIENT SAFETY A NEW LASER FOCUS ON PATIENT SAFETY PATIENT SAFETY STARTS HERE During CT Simulation, clinics rely on moveable lasers to mark where radiation will enter a patient s body to target the tumor. Fixed lasers

More information

Intensity-modulated radiation therapy dose maps: the matchline effect

Intensity-modulated radiation therapy dose maps: the matchline effect University of Wollongong Research Online University of Wollongong Thesis Collection 1954-2016 University of Wollongong Thesis Collections 2006 Intensity-modulated radiation therapy dose maps: the matchline

More information

Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free beams

Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free beams JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 15, NUMBER 2, 2014 Commissioning and verification of the collapsed cone convolution superposition algorithm for SBRT delivery using flattening filter-free

More information

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR

MCNP4C3-BASED SIMULATION OF A MEDICAL LINEAR ACCELERATOR Computational Medical Physics Working Group Workshop II, Sep 3 Oct 3, 7 University of Florida (UF), Gainesville, Florida USA on CD-ROM, American Nuclear Society, LaGrange Park, IL (7) MCNP4C3-BASED SIMULATION

More information

IMRT site-specific procedure: Prostate (CHHiP)

IMRT site-specific procedure: Prostate (CHHiP) IMRT site-specific procedure: Prostate (CHHiP) Scope: To provide site specific instructions for the planning of CHHIP IMRT patients Responsibilities: Radiotherapy Physicists, HPC Registered Therapy Radiographers

More information

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved

The IORT Treatment Planning System. radiance. GMV, 2012 Property of GMV All rights reserved The IORT Treatment Planning System radiance Property of GMV All rights reserved WHY RADIANCE? JUSTIFICATION Property of GMV All rights reserved ADVANTAGES OF IORT PRECISION: RT guided by direct vision.

More information

Transitioning from pencil beam to Monte Carlo for electron dose calculations

Transitioning from pencil beam to Monte Carlo for electron dose calculations Transitioning from pencil beam to Monte Carlo for electron dose calculations Jessie Huang-Vredevoogd (jyhuang4@wisc.edu) University of Wisconsin NCC AAPM October 12, 2019 1 Topics to cover Background RayStation

More information

Version 3.7. User Manual

Version 3.7. User Manual WWW..COM Version 3.7 User Manual STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 May / 2016 2016 Standard Imaging, Inc. TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 www.standardimaging.com

More information

Verification measurements of an emc algorithm using a 2D ion chamber array

Verification measurements of an emc algorithm using a 2D ion chamber array JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 5, 2016 Verification measurements of an emc algorithm using a 2D ion chamber array Mark D. Wanklyn, 1a Ghirmay Kidane, 2 and Liz Crees 2 Medical

More information

Tumor motion during liver SBRT

Tumor motion during liver SBRT Tumor motion during liver SBRT - projects at Aarhus University Hospital - Per Poulsen, Esben Worm, Walther Fledelius, Morten Høyer Aarhus University Hospital, Denmark SBRT: Stereotactic Body Radiation

More information

Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field

Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 5, 2016 Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field Hideharu Miura, 1a Shuichi

More information

Considerations in Designing a Commissioning and QA protocol for HyperArc

Considerations in Designing a Commissioning and QA protocol for HyperArc Considerations in Designing a Commissioning and QA protocol for HyperArc Version 1.0 Contributors: University of Alabama at Birmingham, Birmingham, AL (UAB) Department of Radiation Oncology Richard Popple,

More information

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools

3D SCANNER. 3D Scanning Comes Full Circle. Your Most Valuable QA and Dosimetry Tools 3D SCANNER 3D Scanning Comes Full Circle Your Most Valuable QA and Dosimetry Tools BETTER OUTCOMES THROUGH TECHNOLOGY The 3D SCANNER is different by design. 3D SCANNER has been developed from the ground

More information

Integrated proton-photon treatment planning

Integrated proton-photon treatment planning Pinnacle 3 Proton Planning Integrated proton-photon treatment planning Philips Pinnacle 3 Proton Planning specifications Pinnacle 3 Proton Planning is designed to simplify treatment planning for proton

More information

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans

A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans Louisiana State University LSU Digital Commons LSU Master's Theses Graduate School 2013 A secondary monitor unit calculation algorithm using superposition of symmetric, open fields for IMRT plans Adam

More information

Impact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-Mv Intensity-Modulated Radiation Therapy Treatment Plans

Impact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-Mv Intensity-Modulated Radiation Therapy Treatment Plans Louisiana State University LSU Digital Commons LSU Master's Theses Graduate School 2015 Impact of Multileaf Collimator Configuration Parameters on the Dosimetric Accuracy of 6-Mv Intensity-Modulated Radiation

More information

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram

TomoTherapy Related Projects. An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram TomoTherapy Related Projects An image guidance alternative on Tomo Low dose MVCT reconstruction Patient Quality Assurance using Sinogram Development of A Novel Image Guidance Alternative for Patient Localization

More information

Evaluation of the Elekta Synergy concept for patient positioning in image guided radiotherapy

Evaluation of the Elekta Synergy concept for patient positioning in image guided radiotherapy Master of Science Thesis Evaluation of the Elekta Synergy concept for patient positioning in image guided radiotherapy Johan Renström Supervisor: Per Nilsson, PhD and Tommy Knöös, PhD Medical Radiation

More information