MULTI 9 System Catalog

Size: px
Start display at page:

Download "MULTI 9 System Catalog"

Transcription

1 MULTI 9 System Catalog Class 80 CONTENTS Schneider Electric Brands Description Page SectionIntroduction... Section UL 89 Listed Circuit Breakers and UL 77 Recognized SupplementaryProtectors... SectionIEC097-RatedProtectionDevices... SectionIECRatedGround-faultProtectionDevices...9 SectionAccessories...7 SectionAdditionalSystemDevices...9 Section7Dimensions...7 Section8Time/CurrentCurves...7 Section9CurrentLimitingCurves...7 SectionApplications...8 Index...87 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

2 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

3 Table of Contents Table of Contents SECTION INTRODUCTION... MULTI 9 Products for OEM Applications... Conformance to Standards... 7 SECTION UL 89 LISTED CIRCUIT BREAKERS AND UL 77 RECOGNIZED SUPPLEMENTARY PROTECTORS... Selection Tables... UL 89 Listed C0N Circuit Breakers... UL 89A and UL 89 Listed C0N DC Circuit Breakers... 7 UL 77 Recognized C0 Supplementary Protectors... 8 UL 77 Recognized NC0H Supplementary Protectors... 0 SECTION IEC 097- RATED PROTECTION DEVICES... Overview... DPN-N Phase + Neutral Circuit Breakers... IEC Rated C0 Miniature Circuit Breakers... IEC Rated CH-DC Circuit Breakers for DC Circuits... IEC Rated NC0H Circuit Breakers... 7 SECTION IEC RATED GROUND-FAULT PROTECTION DEVICES... 9 Selection Table... 9 IEC Rated C0 VIGI Modules for Ground-fault Protection... 0 IEC Rated NC0 VIGI Residual Current Circuit Breakers... DPN-N VIGI Residual Current Circuit Breakers... IEC Rated ID Residual Current Switches... SECTION ACCESSORIES... 7 MULTI 9 C0 and NC0 Accessories... 7 Electrical Auxiliaries... 8 Overview... 8 MN Undervoltage Release... 8 MN s Time-delayed Undervoltage Release... 9 MX + OF Shunt Trip and Auxiliary Switch... 9 OF Auxiliary Switch... 9 SD Alarm Switch... 0 TM Motor Operator... UL Recognized C0 Comb Bus Bars... Connectors... Tooth Caps... Device Shielding... Spacer... Interphase Barriers... Terminal Screw Shields... Terminal Covers... Ring Lug Terminal Kit... Identification System... Snap-on Marking Symbols... Operation Devices... Rotary Handles... Padlock Attachments... Mounting Accessories... Plug-in Base... Front Mounting Bracket (Kit)... MSC Mounting Base... 7 Multi-pole Front Mounting Kit / Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

4 Table of Contents SECTION ADDITIONAL SYSTEM DEVICES... 9 Overview... 9 CM Selector Switches... 9 I Isolating Switch... 0 OFS Auxiliary Switch Adapter (for ID RCD)... 0 Status, Display and Control Accessories... V Signal Lamps... BP Push Buttons... CH Hour Counter... CI Impulse Counter... IH and IHP Time Switches... Mini PRAGMA DIN Type Enclosures... Mini PRAGMA Weatherproof Type Enclosures... PRAGMA F DIN Type Enclosures... SECTION 7DIMENSIONS... 7 UL 89 Listed C0 Circuit Breakers... 7 UL 89a Listed Circuit Breakers for DC Applications...7 UL Recognized Circuit Breakers and IEC Rated Supplementary Protectors... 7 Accessories for C0 Devices... 9 MINI-PRAGMA Din Type Enclosures... PRAGMA Weatherproof Type Enclosures... PRAGMA F DIN Type Enclosures... SECTION 8TIME/CURRENT CURVES... 7 UL 89 Listed Circuit Breakers... 7 UL 89A Listed Circuit Breakers...7 UL 77 Recognized Supplementary Protectors... 8 IEC 097- Rated DPN-N Residual Current Circuit Breakers SECTION 9CURRENT LIMITING CURVES... 7 UL Listed and UL Recognized Supplementary Protectors... 7 IEC 097- Rated Circuit Breakers SECTION APPLICATIONS... 8 Degree of Protection (IP)... 8 Overview... 8 Vibrations... 8 Mechanical Shocks (IK)... 8 Protection of 00 Hz Circuits... 8 Temperature Rating... 8 Typical IEC Grounding Systems... 8 Codification of the Grounding Systems... 8 The TT Grounded Neutral System... 8 The IT Grounding System... 8 The TN-S Grounding System... 8 INDEX Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

5 Section Introduction SECTION INTRODUCTION MULTI 9 PRODUCTS FOR OEM APPLICATIONS Overview Applications System Flexibility The MULTI 9 modular system of miniature circuit breakers and supplementary protectors, accessories, and peripherals is ideal for use by OEMs to provide complete protection of equipment or especially sensitive circuits within the equipment. Installation labor and space are both minimized by the modular architecture of the MULTI 9 system, whether a single protective device or multiple devices with their accessories are being used. All MULTI 9 products are in compliance with applicable IEC Standards. Many are also compliant with UL Standard 77 as supplementary protectors or UL 89 as circuit breakers. To an OEM, this means that one family of electrical protection products can be used regardless of equipment destination. The Standards include: UL 89 Standard for Circuit Breakers UL 89A Standard for dc Communication Applications UL 77 Standard for Supplementary Protectors IEC 097- IEC 0898 CSA C. Potential applications include semi-conductor machines, communication equipment, computers, medical equipment, electronic controls, transformers, power supplies, and other electrical equipment. The MULTI 9 System includes an extensive line of field-installable accessories. Plug-on electrical auxiliaries include shunt trip, undervoltage release, auxiliary switch, and alarm switch. Other protection devices include residual current detectors, dc circuit breakers, and switches. Control and display devices include signal lamps, push buttons, and motor operators. There are also mechanical accessories for locking, operating, shielding, mounting, etc. See the following functional diagram, which shows many of the accessories of the MULTI 9 system. Status and Display Output Control Inputs CI Impulse Counter CH Hour Counter V Signal Lamp V Signal Lamp BP Push Button (N.O.) or Signal BP Push Button (N.C.) or Signal TM Motor Operator Switch or Control Metering Device SD Alarm Switch OF Aux Switch MX + OF Shunt Trip & Aux Switch MN Undervoltage Release C0N Circuit Breaker Vigi Residual Current Device Protected Line Plug-on Electrical Auxilliaries IH and IHP Time Switches I Switch CM Selector Switch DPN-N Residual Current Circuit Breaker OFS & Elect. Accessory ID Residual Current Device OFS & Elect. Accessory CH DC Only Circuit Breaker Figure : Other Devices Used With or Instead of the C0N Device Functional Diagram of MULTI 9 System 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

6 Section Introduction Advantages MULTI 9 C0 and NC0 circuit breakers and supplementary protectors provide several advantages which are important to OEMs. These include: Small, compact size Easy installation on DIN rails Current-limiting, to provide more protection to sensitive circuits Resettability, for more convenience than fuses Communication capabilities for control and status information Extensive variety of accessories Better ProtectionMULTI 9 supplementary protectors and miniature circuit breakers are current limiting, providing faster separation of the component from the fault, thereby reducing system damage. More SelectionMore ratings compatible with low-power electronic circuits are available in the range from 0. to A. Others are provided in convenient steps, up to A for the C0 and up to 80 A for the NC0 products. Reduction of Nuisance TrippingAvailable with different trip characteristics to meet system needs: B, C, D, and MA curves, depending on the model. Panel Space SavingsMULTI 9 products are compact. Width per pole is only 0.7 in. (8 mm) for the C0 circuit breaker and.0 in. (7 mm) for the NC0 circuit breaker. All of the products are built in a consistent format with incremental widths of 0. in. (9 mm) modules (therefore the name MULTI 9 ). Easy InstallationThe MULTI 9 modules mount easily onto a mm DIN mounting rail. Large box lug terminals (pressure plate type) are suitable for use with copper wiring up to # AWG or multiple wires (for C0 series) and # AWG for the NC0 series. ReliabilityEach C0 miniature circuit breaker has an endurance of 0,000 operation cycles and voltage withstand of 000 V impulse rating. World-wide AvailabilityThe MULTI 9 products are available and supported throughout the world by Schneider Electric family, including Square D and Merlin Gerin. From the Power Distribution SpecialistsSquare D can be your single source of protection equipment, with a comprehensive line of products for OEM products or the factory. These other products include the following: QO and QOU Miniature Circuit Breakers A COMPACT Molded Case Circuit Breakers 00 A POWERPACT Electronic Trip Circuit Breakers 0 00 A MASTERPACT Universal Power Circuit Breakers 0 00 A Figure : -, -, and -pole UL 89 Listed MULTI 9 C0 Circuit Breakers Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

7 Section Introduction CONFORMANCE TO STANDARDS Overview Conformance to Standards most needed by OEMsUL 89, UL 77 and IEC Different applications call for circuit protection devices that meet different standards. The MULTI 9 family allows OEMs to use a single family of products in their equipment, whether it is destined for the United States or for a foreign market. A variety of MULTI 9 devices are tested per Underwriters Laboratories (UL) Standards that are required by the National Electrical Code (NEC ) in the United States. Others are tested per the standards of the International Electrotechnical Commission (IEC )andmay therefore be used in many foreign countries as these products meet both standards. In this catalog, the products are grouped by the standards they are designed to meet. These standards include the following: UL 89Defines rigorous testing requirements for circuit breakers in the United States UL 89ALimited applications (dc circuits in communications equipment) UL 77Defines supplementary protectors for use within electrical equipment protected by branch circuit breakers IEC 097-International standards for circuit breakers to be used in industrial applications UL 89 Standard Branch Circuit Protection An OEM product as a whole must be appropriately protected from overcurrent conditions, either by connection in the field to a protected branch circuit (in accordance with NEC) or by inclusion of branch circuit protection within the product itself. In the United States, these branch circuit protection devices must comply with the UL 89 Standard for Molded-Case Circuit Breakers. (see UL 89 # in Figure, which is a drawing of a hypothetical piece of OEM equipment requiring multiple protection devices.) Applications Requiring UL 89 Standards In some instances, the protective devices being installed in equipment must comply with UL 89. These include the following situations:. If a circuit such as a convenience receptacle leaves the equipment, that circuit must be protected by aul89branchcircuitprotectiondevice(seeul89#).. If a circuit such as to an external motor leaves the equipment, that circuit must be protected by a UL 89 branch circuit protection device (see UL 89 #).. Motors within the equipment should also be protected by a UL 89 device (see UL 89 #).. All equipment which requires HACR (Heating, Air Conditioning, and Refrigeration) rating must be protected by a UL 89 branch circuit protection device (see UL 89 #). NOTE: The motor control circuit may be protected by a UL 77 device. In general, a UL 89 circuit breaker could also be used in any application for which a UL 77 device is allowed, since the UL 89 devices meet or exceed the requirements of UL 77 devices. The converse of this is not true, since UL 77 devices cannot meet the more stringent UL 89 Standards. UL 77 Standard Supplementary Protection within the Product Within the OEM product itself, additional (supplementary) protection for sensitive or critical internal circuitry may be provided by one or more supplementary circuit protectors. A supplementary protector is an overcurrent protection device which is specifically designed for OEM applications and which complies with UL 77 Standard for Supplementary Protectors for Use in Electrical Equipment. Under UL 77, supplementary protectors may be used under the following conditions: When branch overcurrent protection is already provided If short-circuit protection is needed for sensitive devices within the equipment When wiring connected to the supplementary protector does not exit the equipment to external devices such as receptacles or motors If the UL 77 device does not provide the only means of disconnecting the product 0/ Schneider Electric All Rights Reserved 7 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

8 Section Introduction The following applications illustrated in Figure allow the use of UL 77 supplementary protectors: The supplementary protection is used to supplement or provide additional protection to sensitive components inside the equipment (see UL 77 #). A UL 89 circuit breaker must be located upstream from the equipment. Critical or sensitive internal circuitry (see UL 77 #) such as: Computers and microprocessors Communications equipment Electronic controllers Power supplies Many other types of equipment Motor control circuits may be protected by a UL 77 device, unless the circuit includes a transformer (in which case a UL 89 device is required). Comparing Terminology for UL 89 and 77 Standards The terms used to differentiate these products can cause confusion if a user is not careful. Misapplying the terms may result in misapplication of the products. Any one of the following terms can be used to identify supplementary protectors: Supplementary protector UL Recognized UL 77 The reverse UR symbol Any of the following terms can be used to identify circuit breakers: Circuit breaker UL Listed UL 89 TheULsymbol UL 89A Standard UL 8 Standard IEC 097- Standard IEC 898 Standard DC Communication Applications The 89A Standard covers dc rated circuit breakers intended to provide branch circuit protection in communications equipment. The products are marked as UL Listed circuit breakers for use in communication equipment. Connection Terminals The UL 8 Standard applies to compression wiring connection terminals. It is a requirement for connections of a UL 89 circuit breaker. Although it is not a requirement for UL 77 Recognized devices, UL 8 Rated terminals are included on those MULTI 9 products. This allows the user to apply field wiring directly to any of these devices, without using intermediate, UL rated terminal blocks. The connectors on MULTI 9 devices are Rated UL 8A, which applies to copper conductors. These standards apply to field-wired terminals that are an integral part of the equipment. Criteria includes static heating tests, secureness tests, and pull-out tests. In countries which follow the IEC Standards, IEC 097- is used for most industrial applications of circuit protection. IEC 097- does not distinguish between the two levels of protection equivalent to UL 89 circuit breakers and 77 supplementary protectors. Therefore, in equipment like that illustrated In the example equipment below, if IEC guidelines apply, then all of the devices could be selected from the IEC Rated portion of this catalog. The IEC 898 Standard is less stringent than It applies primarily to residential applications of circuit breakers in countries adhering to IEC Standards, and is not generally applicable to OEMs Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

9 Section Introduction CSA C. Standard UL 08 Standard The CSA (Canadian Standards Association ) C. Standards closely correspond to the UL Standards: CSA C. No.. (equivalent to UL 89) and CSA C. No. (equivalent to UL 77). Industrial Control EquipmentManual Motor Controllers UL Standard 08 covers industrial control equipment, specifically for motor control functions. It covers individual devices as well as assemblies. There are UL 08 Listed manual motor controllers that look much like miniature circuit breakers, and have thermal settings and instantaneous settings similar to circuit breakers. These are specialized devices and cannot be used for a wide range of applications, as can UL 77 and 89 devices. Like UL 77 supplementary protectors, a UL 08 Listed manual motor controller (or a group of them) must be protected by a UL 89 branch circuit breaker. These manual motor controllers are available from Schneider Electric (Telemecanique products GV and GV) but are not included in this catalog. Feeder or Branch Circuit UL 89 Listed Molded Case Circuit Breaker (MCCB) or Miniature Circuit Breaker (MCB) 080 UL 77 Applications Permitting Supplementary Protectors Miscellaneous Devices Protected by Branch Circuit Breaker UL 89 Internal Receptacle External Receptacle Supplements or provides additional protection for sensitive electronics inside the equipment. Used on the load side of branch circuit protection to protect critical or sensitive internal circuitry such as: Computers and microprocessors Communications equipment Electronic controllers Power supplies Many other types of equipment UL 77 UL 89 External Motor Permitted for protection of motor control circuits NEC 0-7, unless transformers are in circuit, then UL 89. Electronics UL 89 Applications Requiring Branch Circuit Protection Other Sensitive Devices UL 77 UL 89 Motor Control Internal Motor Protects conductors entering the OEM equipment. This required UL 89 device may be provided integral to the OEM equipment or be external as part of the distribution system. May act as branch circuit protection if it protects the conductor to the utilization equipment. Required to protect convenience receptacle circuits (internal or external) Required to protect an external load circuit leaving the equipment Required for motors in the equipment HACR UL 89 UL 77 Required for HACR equipment (Heating, Air Conditioning, and Refrigeration) Equipment Enclosure Figure : Guidelines for Application of UL 89 Circuit Breakers and UL 77 Supplementary Protectors NOTE: This is a simplified summary of the standards. Refer to applicable codes for specific applications. 0/ Schneider Electric All Rights Reserved 9 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

10 Section Introduction Table : Summary of Applicable UL and IEC Standards Comparison Characteristic UL 89 UL 77 IEC 097- Labeling UL Listed Recognized component IEC Certified device Nomenclature Circuit breakers Supplementary protectors Circuit breakers or supplementary protectors Dielectric test (for 0 Vac) times rated plus 00 V for minute times rated plus,000 V for minute,00 V (,80 at 0 Vac) (,80 at 0 Vac) Interrupting rating,000 ka at 0 Vac,000 ka at 0 Vac 0,000 ka at 0 Vac Overload protection 0 operations at 00% rating 0 operations at 0% rating operations at 00% rating Service capacity Must be operational after two interruptions May be tested in series with branch circuit device Same as UL 89 and may become inoperable after test Calibration test 00% I n,minutesmax.(0 0 A) Per manufacturer s trip curve At 00% I n, time shall not exceed manufacturer s stated value Calibration temperature F (0 C), unless other value specified by Manufacturer must specify Manufacturer must specify manufacturer Testing temperature 77 F ( C) ambient, F (0 C) rise max. at terminals 77 F( C)ambient, F(0 C) rise max. at field wiring terminals; 9 F ( C) rise max. on factory wiring terminals At 77 F ( C) ambient, 7 F (80 C) rise max. at terminals Endurance At rated current and voltage, 7 80% PF,,000 operations At rated current and voltage, 7 80% PF,,000 operations Note: The above is a generalized summary applicable for -pole, 0 A, 0 Vac devices. For other devices or specific details, see the standards. At rated current and voltage, 7 80% PF,,00 operations Air spacing / in. (0. mm) /8 in. (9. mm) See dielectric Surface spacing -/ in. (.8 mm) / in. (.7 mm) See dielectric Test and follow up tests Initial, periodic and quarterly follow-up tests observed by UL representative Initial tests observed by UL representative, plus quarterly follow-up inspection Conducted by manufacturer Labels and Markings. Circuit Breaker Type. Ampere Rating. Trip Curve. Voltage. Standards Marks. Standards Marks 7. Catalog Number 8. UL File Number 9. CSA File Number. Wire Characteristics. Torque. Interrupting Ratings as per UL 89 and VDE 00. Interrupting Ratings as per IEC 097- and VDE Vac 7 Face Markings MERLIN GERIN multi 9 C0N 0.A-type C LISTED C.B. ISSUE No. L-77 Cat. No. 00 IEC Side Markings (Box/Box Terminals) 8 9 UL File : E7 0VAC AIR ka (P) CSA File : 790 VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG TERMINAL SCREW TORQUE lb-in /.8 N m 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka Side Markings (Ring/Ring Terminals) Side Markings (Box/Ring Terminals) 8 9 UL File : E7 0VAC AIR ka (P) CSA File : 790 VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG RING TONGUE TERMINAL TORQUE 8 lb-in /.0 N m 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka 8 9 UL File : E7 0VAC AIR ka (P) CSA File : 790 VAC AIR ka (P) 0VAC AIR ka (-P) MADE IN FRANCE 7 C WIRE # - # 8 AWG TERMINAL SCREW TORQUE lb-in /.8 N m RING TONGUE TERMINAL 0VAC AIR 0kA IEC 097- / VDE 00 VAC AIR ka Figure : Labels and Markings for UL 89 Listed and CSA... Certified C0N Circuit Breakers Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

11 Section Introduction Consult Your Local Square D Field Office for Availability of These Products Figure : Label Markings for UL 89A and UL 89 Listed C0N DC Circuit Breakers. Supplementary Protector Type. Ampere Rating. Trip Curve. Voltage. Standards Marks. Catalog Number 7. UL 77 File Number 8. CSA File Number 9. Interrupting Ratings as per IEC 097- and VDE 00. Interrupting Ratings as per UL Face Markings MERLIN GERIN multi 9 C0N A-type C 77 Vac Cat. No. XXXXX IEC 7 8 Side Markings E VAC INT RATING 000A 790 0VAC INT RATING 000A VDC INT RATING 000A LINE-LOAD CAN BE REVERSED MADE IN XXXXXXX --- MAX 00VAC TO GROUND IEC A AT 0V AC VDE A AT 0V AC 9 Figure : Labels and Markings for UL 77 C0N Supplementary Protectors 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

12 Section Introduction. Supplementary Protector Type. Ampere Rating. Trip Curve. Voltage. Standards Marks. Catalog Number 7. UL 77 File Number 8. CSA File Number 9. Interrupting Ratings as per IEC 097- and VDE 00. Interrupting Ratings as per UL Face Markings MERLIN GERIN multi 9 NC0 80 Vac IEC Cat. No. XXXXX 0A-type C 7 8 Side Markings EXXXXX 80VAC INT RATING 000A XXXXXX 0VAC INT RATING 0000A LINE-LOAD CAN BE REVERSED MADE IN FRANCE--- MAX 00V AC TO GROUND IEC 097- XXXXXX A AT 0V (ou V) VDE 00 XXXXXX A AT 0V (ou V) 9 Figure 7: Labels and Markings for UL 77 NC0 Supplementary Protectors Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

13 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors SECTION UL 89 LISTED CIRCUIT BREAKERS AND UL 77 RECOGNIZED SUPPLEMENTARY PROTECTORS Overview The MULTI 9 system includes four families of miniature circuit protection devices that have the UL Ratings required in the United States and some other countries. The products are summarized below and are described in detail on the following pages. They include the following families: UL Listed C0 Circuit Breakers (UL 89) UL Listed C0 Circuit Breakers for use in Communication Equipment (UL 89A) UL Recognized C0 Supplementary Protectors (UL 77) UL Recognized NC0 Supplementary Protectors (UL 77) IEC Rated protection devices are described in Sections and, while accessories for both the UL and IEC devices are described in Section. SELECTION TABLES Table : Selection Table for UL 89 and 89A Listed C0 Circuit Breakers Ratings per UL Standards UL 89 C0N UL 89A C0N Number of poles Rated current (A) at 77 F ( C) Interrupting ratings as per UL 89 (ka RMS) Ultimate breaking capacity (I cu ) as per IEC 097- (ka RMS) AC 0/0 Hz DC AC 0/0 Hz V 0 V 77 V 80Y/77 V 0 V V 0 V V 0 V Service breaking capacity (I cs )(%I cu ) 7% 7% 7% 7% Trip Units Magnetic setting (times ampere rating) Dimensions and Weights B curve Ccurve Dcurve Between 7 and times ampere rating Between and times ampere rating Dimensions (in./mm) Width 0.7/8././ 0.7/8 Weight (oz./g) max. Height box/box ring/ring box/ring./7.8/../ 7to.9/8 Depth.00/7.00/7 box/box ring/ring box/ring././.8/8 8.7/7./ 9./97./07./8./.8/ Figure 8: -, -, and -pole UL 89 Listed MULTI 9 C0 Circuit Breakers 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

14 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors Table : Selection Table for UL 77 Recognized Supplementary Protectors Ratings per UL Standards UL 77 C0N UL 77 NC0 Number of poles Rated current (A) at 77 F ( C) Interrupting ratings as per UL 77 (ka RMS) Ultimate breaking capacity (I cu ) as per IEC 097- (ka RMS) 0/0 Hz 0/0 Hz Vac 0 Vac 77 Vac 80Y/77 Vac Vdc Vdc 0 Vac Vac 0 Vac Service breaking capacity (I cs )(%I cu ) 7% 7% 7% 7% Trip Units Magnetic setting Bcurve Ccurve Dcurve Dimensions and Weights Dimensions (in./mm) Width Height Depth Between. and.8 times ampere rating Between 7 and times ampere rating Between and times ampere rating (no dc rating for D curve); D curve dc supplementary protector rating ( A through A) 0.7/8.9/8.00/7./.9/8.00/7./.9/8.00/7.8/7.9/8.00/7.0/7.9/8.00/7 0 0./.9/8.00/ /8.9/8.00/ /8.9/8.00/7 Weight (oz./g).8/ 7.70/0./0.0/0./80.70/0 9.0/0./70 0 Figure 9: UL 77 Recognized C0N -, -, - and -pole Supplementary Protectors Figure : UL 77 Recognized NC0H -, -, - and -pole Supplementary Protectors Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

15 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors UL 89 LISTED C0N CIRCUIT BREAKERS Overview A family of circuit breakers meeting UL 89 requirements is now available in the MULTI 9 product line. These products meet many applications in which UL 77 Recognized supplementary protectors are not allowed. As shown in the table of catalog numbers below, the UL 89 Listed products are available in C and D curves. They include devices ranging from 0. A to A. Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads. Trip-free mechanism: Contacts cannot be held in the on (O) position when the C0 circuit breaker is tripped automatically. Isolation with positive break indication: Green strip on the operating handle indicates that all poles are open. C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to times ampere rating. D curve: Overcurrent protection for loads with high inrush currents (motors, transformers). Magnetic release operates between and times ampere rating. Connection Two versions of field wiring connectors are available for the UL 89 Listed devices: Box lug meeting UL 8A requirements Ring tongue terminal with mm screw The circuit breakers can be ordered with the following combinations of connectors: Box/Box Ring/Ring Box/Ring Line terminal box lug/ load terminal box lug Line terminal ring tongue/ load terminal ring tongue Line terminal box lug/ load terminal ring tongue 0809 Figure : Connection Options for UL 89 Listed Devices Table : Specifications for UL 89 Listed Circuit Breakers Package size: Two 0. in. (9 mm) modules; 0.7 in. (8 mm) width per pole Voltage (nominal): and 0 Vac delta High voltage withstand: kv Connection, box lug: 0. A: #8 # AWG ( mm ) cables; torque lb-in. (.8 N m) 0 A: #8 # AWG ( mm ) cables; torque lb-in. (. N m) Connection, ring terminal: Use single UL Listed or CSA Certified insulated ring tongue only, with screw dia. 0. in. ( mm); torque 8 lb-in. (.0 N m) Mounting:.8 in. ( mm) DIN rail Time/Current curves: C and D curves Degree of protection: Case: IP0 as per IEC 9 Terminals: IP0 Rating on ring tongue connector: UL 8A File #E9009 (use with copper wire only) Screw dia. 0.0 in. ( mm) Recommended terminal width.7 in. (0 mm) Temperatures: Calibration: 77 F ( C) Storage: -0 to 7 F (-0to80 C) Operating: - to 8 F (-0to70 C) Tropicalization: Treatment relative humidity: 9% at F ( C) Number of operating cycles: Electrical (O-C):,000 load,,000 no-load See selection table for weights and interrupting ratings Standards UL 89 Circuit Breaker: File #E7 CSA C. #. Circuit Breakers: File #790 IEC 097- VDE 00, CE Marked 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

16 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors Table : C Curve, with UL 89 Listed Termination Options (line/load as box lug or ring tongue terminals) Rating (A) -pole -pole -pole Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring Table : D Curve, with UL 89 Listed Termination Options (line/load as box lug or ring tongue terminals) Rating (A) -pole -pole -pole Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring Box/Box Ring/Ring Box/Ring NOTE: The UL 89 Listed MULTI 9 C0N circuit breakers are certified at 77 F( C), unlike some other UL 89 circuit breakers which are certified at F (0 C). Depending on the operating environment, you may need to rerate according to the tables on page 8 to determine the appropriate handle rating. NOTE: UL 89 Listed circuit breakers should be loaded to no more than 80% if used with continuous loads; that is unlike UL 77 recognized supplementary protectors, which may be operated at 0% of rating Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

17 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors UL 89A AND UL 89 LISTED C0N DC CIRCUIT BREAKERS Consult your local Square D field office for: Catalog numbers Specifications Product availability 0/ Schneider Electric All Rights Reserved 7 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

18 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors UL 77 RECOGNIZED C0 SUPPLEMENTARY PROTECTORS Overview AfamilyofMULTI9 supplementary protectors meeting the UL 77 Standard is available. These UL 77 products are intended for use as supplementary protectors to provide overcurrent protection within appliances or electrical equipment where branch circuit protection is already provided or is not required. As shown in the table of catalog numbers below, the UL 77 Recognized products are available in B, C and D curves. They include devices ranging from 0. A to A. (For higher current ratings, select devices from the higher current NC0 series.) Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when the C0 is tripped automatically. Positive break indication: Green strip on the operating handle indicates that all poles are open. B curve: Overcurrent protection for sensitive equipment (computers, electronic devices, etc.). Magnetic release operates between. and.8. C curve: Overcurrent protection for all application types. Magnetic release operates from 7 to times ampere rating. D curve: Overcurrent protection for loads with high inrush currents (motors, transformers). Magnetic release operates between and times ampere rating. Allows locking in OFF position using padlock attachment. NOTE: Other features of the UL 77 Recognized C0 circuit breaker are identical to those of the UL 89 version. A variety of accessories are available for these products. Table 7: Specifications for UL77 Recognized C0 Supplementary Protectors Package size: Two 0. in. (9 mm) -pole modules; 0.7 in. (8 mm) width Voltage (nominal): 80Y/77 Vac High voltage withstand: kv Connection, box lug 0. A: #8 # AWG ( mm )cables; torque lb-in (.9 N m) 0 A: #8 # AWG ( mm )cables; torque lb-in (.0 N m) Connection, ring terminal kit: Cat. No. 700 Two ring tongue terminals and two isolation barriers Use single UL Listed or CSA Certified and insulated ringtongue terminal only Mounting: (.8 in.) mm DIN rail Time-current curves: B, C, and D curves Degree of protection as per IEC8--0: Case: IP0 as per IEC 9 Terminals: IP0 Rating on connector: UL 8A File #E9009 pending; use with copper wire only. Screw dia.: 0. in. (mm); torque 8 lb-in (.0 N m) Temperatures: Calibration: 77 F ( C) Storage: -0 to 7 F (-0to80 C) Operating: to 8 F (-0to70 C) Tropicalization: Treatment relative humidity: 9% at F ( C) Number of operating cycles electrical (O-C):,000 at 0. A See selection table for weights and interrupting ratings Standards UL 77 Circuit Breaker, File #E9009 CSA C. #-M89 File # 790 IEC 097-, VDE 00, CE Marked Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

19 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors Table 8: Catalog Numbers for UL 77 Recognized C0N Supplementary Protectors Rating (A) BCurve CCurve DCurve -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules 0... MG MG70 MG70 MG MG7 MG7 MG0 MG MG7 MG MG7 MG7 MG MG7 MG7 MG9 MG7 MG7 MG00 MG7 MG7 MG MG7 MG7 MG MG8 MG MG MG MG70 MG MG7 MG8 MG7 MG MG MG MG MG7 MG8 MG MG7 MG8 MG7 MG MG MG MG7 MG0 MG MG MG77 MG78 MG79 MG0 MG0 MG0 MG7 MG7 MG8 MG9 MG7 MG MG MG MG9 MG0 MG 7 8 MG MG70 MG MG MG9 MG7 MG0 MG MG MG MG MG9 MG0 MG MG0 MG7 MG MG MG7 MG7 MG8 MG9 MG MG MG MG8 MG8 MG8 MG0 MG7 MG0 MG0 MG0 MG7 MG MG MG MG7 MG8 MG MG MG 0 MG7 MG70 MG8 MG9 MG MG7 MG MG MG7 MG7 MG8 MG9 MG MG MG MG MG7 MG MG MG0 MG7 MG MG MG7 MG7 MG8 MG9 MG8 MG8 MG8 MG07 MG7 MG08 MG09 MG MG7 MG MG MG9 MG77 MG0 MG MG MG MG7 0 MG MG707 MG MG708 MG MG77 MG MG78 MG0 MG7 MG MG7 MG MG MG MG77 MG7 MG78 MG MG77 MG MG78 MG70 MG77 MG7 MG78 MG87 MG88 MG MG77 MG MG78 MG MG77 MG7 MG78 MG MG77 MG MG77 MG8 MG MG MG MG709 MG MG7 MG8 MG79 MG9 MG MG MG7 MG MG7 MG8 MG9 MG8 MG9 MG79 MG0 MG MG MG79 MG7 MG7 MG7 MG79 MG7 MG89 MG90 MG9 MG MG MG79 MG MG8 MG9 MG79 MG0 MG MG MG77 MG MG0 MG MG Figure : UL 77 Recognized C0N -, -, - and -pole Supplementary Protectors 0/ Schneider Electric All Rights Reserved 9 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

20 Section UL 89 Listed Circuit Breakers and UL 77 Recognized Supplementary Protectors UL 77 RECOGNIZED NC0H SUPPLEMENTARY PROTECTORS Overview The NC0H family of MULTI 9 UL 77 Recognized supplementary protectors is available for applications requiring higher current levels than available in the C0 family These UL 77 Listed products are intended for use as supplementary protectors to provide overcurrent protection within appliances or electrical equipment where branch circuit protection is already provided or is not required. These products are similar to the C0, except larger in size (three 0. in. [9 mm] modules or a total of.0 in. [7 mm] per pole). In many cases, the accessories for the C0 products will not function with the NC0. Separate accessories are available (see accessories in Section ). Standard Features Fast closing: Allow increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when the NC0 circuit breaker is tripped automatically Isolation with positive break indication: Green strip on the operating handle indicates that all poles are open B curve: Overcurrent protection for sensitive equipment such as computers and electronics. The magnetic release operates between. and.8 times ampere rating. C curve: Overcurrent protection for all application types. The magnetic release operates between 7 and times ampere rating. D curve: Overcurrent protection for loads with high inrush currents such as motors and transformers. The magnetic release operates between and times ampere rating. Ground-fault protection with optional add-on VIGI module (see accessories in Section ). Table 9: Specifications for UL Recognized NC0H Supplementary Protectors Current rating: 80 A Package size: Three 0. in. (9 mm) modules;.0 in. (7 mm) width per pole Voltage (nominal): 0, 80Y/77; up to Vdc High voltage withstand: kv Connection, box lug: 0 A: #8 # AWG ( mm )cables; torque lb-in. (. N m) 0 80 A: #8 # AWG ( 0 mm )cables; torque 9 lb-in. (. N m) Connection: Use with copper wire only Mounting:.8 in. ( mm) DIN rail Degree of protection: Case: IP0 as per IEC 9 Terminals: IP0 Time/Current curves: C and D curves Temperature: Calibration: 77 F ( C) Operation: to 0 F (-to0 C) Storage: -0 to F (-0 to 0 C) Tropicalization: Treatment relative humidity: 9% at F ( C) as per IEC8--0 Number of operating cycles (O C): 0,000 See selection table for weights and interrupting ratings Standards UL 77 Circuit Breaker File #E9009 CSA C. No. -M89 file #LR8089 IEC 97- VDE 00 CE Marked. Table : Catalog Numbers for UL 77 Recognized NC0H Supplementary Protectors Rating (A) BCurve CCurve DCurve -pole Modules -pole Modules -pole 9 Modules -pole Modules -pole Modules MG7 MG8 MG7 MG7 MG77 MG87 MG78 MG88 MG79 MG70 MG89 MG7 -pole Modules MG7 MG87 MG77 MG78 MG79 MG770 MG770 MG87 MG77 MG77 MG87 MG7 -pole 9 Modules MG777 MG88 MG778 MG779 MG780 MG887 MG78 MG888 MG78 MG78 MG889 MG77 -pole Modules MG788 MG789 MG790 MG79 MG79 MG79 MG79 MG77 -pole Modules MG7 MG8 MG7 MG7 MG7 MG8 MG77 MG8 MG78 -pole Modules MG7 MG87 MG7 MG7 MG77 MG877 MG78 MG878 MG79 -pole 9 Modules MG7 MG89 MG7 MG77 MG78 MG89 MG79 MG89 MG70 80 MG7 MG77 MG78 MG797 MG7 MG77 MG78 MG79 -pole Modules MG7 MG77 MG78 MG79 MG770 MG Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

21 SECTION IEC 097- RATED PROTECTION DEVICES MULTI 9 System Catalog Section IEC 097- Rated Protection Devices OVERVIEW The MULTI 9 System includes several families of miniature circuit protection devices that have the IEC Ratings that are applicable in many countries other than the United States. These products are summarized below and discussed in more detail in the following pages. UL Listed and UL Recognized protection devices are described in the previous Section, while accessories for both the UL and IEC Rated devices are described in Section of this catalog. Table : Selection Table for IEC Rated Miniature Circuit Breakers Ratings per IEC 097- Standards DPN-N C0N C0H C0L CH-DC NC0H, NCH Number of poles (Ø + N),,,,,,,, Rated current (A) 77 F ( C) Rated current (A) F (0 C) I n I n 0 0 Rated voltage (V) U e Ultimate breaking capacity as per IEC 097- Standard (ka RMS) Service breaking capacity Ultimate breaking capacity as per IEC 898 (ka RMS) Trip Units Magnetic setting 0 Vac 0 0 Vac 00 Vac 0 Vac 7 Vdc 0 Vdc 7. * * Single pole breaking capacity for IT type European grounding system (insulated neutral-double fault). * 0 I cs (%I cu ) 0% 7% 7% 0% 0% 0% 7% 7% 0 00 Vac Vac Bcurve Ccurve Dcurve MA curve Zcurve * Table : Dimensions (in./mm) and Weights (oz./g) Device Size Height Width Depth Weight DPN-N -pole.9/8 0.7/8.00/7./ C0N C0H C0L CH-DC NC0H/NCH -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole -pole.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8.9/8.0/77.0/77.9/8.9/8.9/8.9/8 0.7/8././.8/7 0.7/8././.8/7 0.7/8././.8/7 0.7/8./ 0.7/8./.9/8./8.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.00/7.88/ 7.7/0./0./0./ 8.7/0.70/0.9/80./ 8.7/0.70/0.9/80.8/7 8.7/0./80.70/0 9.0/0.0/ Figure : IEC Rated C0 Circuit Breakers 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

22 Section IEC 097- Rated Protection Devices DPN-N PHASE + NEUTRAL CIRCUIT BREAKERS Overview Time/Current Curves Accessories The DPN-N Phase + Neutral Current Circuit Breaker provides phase and neutral protection against short-circuit and overload. It provides protection on the phase pole, but switches both the phase and neutral. The DPN-N is available in only one version phase + neutral. The DPN-N circuit breaker is available with B or C curve characteristics and with ratings from to 0 A. BcurveProvides control and protection against overcurrents for very long cables. Magnetic trip units operate between and times ampere rating. CcurveProvides control and protection against circuit overcurrents in tertiary and industrial final distribution with TT or TNS grounding systems. Magnetic trip units operate between and times ampere rating. These devices may be used in conjunction with the C0 electrical accessories, including the SD Alarm Switch, OF Auxiliary Switch, MN Undervoltage Release, and/or the MX + OF Shunt Trip and Auxiliary Switch. The VIGI residual current detector can be added to the DPN-N to provide residual current protection. This combination must be ordered as an integral product from the factory (see section for the VIGI residual current detector). Table : Specifications for IEC Rated DPN-N Phase + Neutral Circuit Breakers Package size: Two 0. in. (9 mm) modules; 0.7 in. (8 mm) width per pole Connection: #8 AWG ( mm ) stranded cables # AWG ( mm ) solid cable (copper only) Mounting: mm DIN rail Degree of protection: Case: IP0 as per IEC 9; Terminals: IP0 Time-current trip curve: B curve and C curve Temperature: Calibration at 8 F (0 C) Storage: 0 to 7 F (-0to80 C) Operating: to 8 F (-0to70 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) as per IEC8--0 Number of operating cycles: Mechanical: 0,000 (O-C) Electrical: 0,000 at -0 A,,000 at A,,000 at A,,000 at 0 A See selection table for weights and interrupting ratings Standards: IEC 097- IEC 898 Table : DPN-N Phase + Neutral Circuit Breaker Catalog Numbers Rating (A) 0 0 BCurve -pole + Neutral Modules CCurve -pole + Neutral Modules N 080 N Figure : DPN-N Phase + Neutral Circuit Breaker Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

23 Section IEC 097- Rated Protection Devices IEC RATED C0 MINIATURE CIRCUIT BREAKERS Overview AfamilyofMULTI9 circuit breakers meeting IEC 097- is available primarily for equipment for export from the United States to countries not requiring UL Ratings. As shown in the table below, three types of IEC Rated C0 devices are available: C0N, C0H, and C0L circuit breaker. These model numbers refer to the maximum current interrupting rating. The relative interrupting ratings per IEC 097- are listed below; for other ratings, see the table on the next page. Table : Ratings Overview Circuit Breaker Rating Curves C0N C0H C0L ka at Vac ka at Vac ka at Vac B, C and D B, C and D B, C, K and MA Each of these devices is available in several trip curves, as listed in the tables with catalog numbers. They include devices ranging from 0. to A. (For higher current ratings, select devices from the higher current NC0 series.) Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when the C0 device is tripped automatically. Isolation with positive break indication: Green strip on the operating handle indicates that all poles are open. B curve: Overcurrent protection for sensitive equipment (computers, electronic devices, etc.): C0N/H: The magnetic operates between and times ampere rating. C curve: Overcurrent protection for all application types: C0N/H: The magnetic operates between and times ampere rating. C0L: The magnetic operates between 7 and times ampere rating. D and K curves: Overcurrent protection for loads with high inrush currents (motors, transformers): C0N/H/L: The magnetic release operates between and times ampere rating. MA curve: C0L-MA circuit breakers are designed for motor circuit protection against short circuits. These circuit breakers are equipped with magnetic only trip units. Therefore they must be combined with a suitable thermal protection device (see the coordination table at the end of this section). Table : MULTI 9 C0 Circuit Breakers with IEC 097- Rating Package size: Two 0. in. (9 mm) modules; 0.7 in. (8 mm) width per pole High voltage withstand: kv Connections for C0N/H/L (box luguse with copper wire only) Ring tongue terminal is optional 0. A, #8 # AWG ( mm ) cables; torque 8 lb-in. (.0 N m) 0 A, #8 # AWG ( mm ) cables; torque 0 lb-in. (.8 N m) Connections for C0L-MA:. stranded # AWG ( mm ). solid#awg(mm ). 0 stranded # AWG ( mm ). 0solid#AWG(mm ) Mounting:.8 in. ( mm) DIN rail Time-current curves: B, C, D, K, and MA Degree of protection: Case: IP0 as per IEC 9 Terminals: IP0 Temperature: Calibration temperature: 8 F (0 C); C0L rated at F (0 C) Storage temperature: -0 to 7 F (-0to80 C) Operating temperature: - to 8 F (-0to70 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) per IEC8--0 Number of operating cycles: Mechanical (O-C) 0,000 Electrical (O-C),000 See selection table for weights and interrupting ratings Standards IEC 097- VDE 00, CE Marked 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

24 Section IEC 097- Rated Protection Devices Table 7: Catalog Numbers for IEC 097- Rated C0N Miniature Circuit Breakers Rating (A) B Curve C Curve D Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules Table 8: Catalog Numbers for IEC 097- Rated C0H Miniature Circuit Breakers Rating (A) B Curve C Curve D Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules Table 9: Catalog Numbers for IEC 097- Rated C0L Miniature Circuit Breakers Rating (A) B Curve C Curve K Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules -pole Modules -pole Modules -pole Modules -pole 8 Modules Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

25 Section IEC 097- Rated Protection Devices Coordination of C0L-MA Circuit Breaker, Thermal Relay and Contactor Standard IEC 097- defines tests at various current levels with the aim of placing the switchgear in extreme conditions. According to the status of components after testing, the standard defines two types of coordination. Table 0: Catalog Numbers for IEC 097- Rated C0L Miniature Circuit Breakers Rating (A) MA Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules Rating (A) MA Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules Deterioration of the contactor and relay is accepted under two conditions: Type There is no risk to the operator Parts other than the contactor and relay must not be damaged Type Welding of the contactor or starter contacts is accepted only if they can be easily separated After Type coordination tests, the functions of protection and operation can be achieved The choice of coordination type depends on the operating parameters. It must be suitable for the user's needs and ensure optimized cost of the installation Table : Tripping Times Class A 0 A Tripping Time (sec.) at 7. I r 0 Type Qualified maintenance service Reduced volume and cost of equipment Continuity of service not required or ensured by replacing the faulty motor bucket Type Continuity of service is vital Reduced maintenance service Specification calling for Type coordination Various thermal relay classes: Thermal relay class must be appropriate for motor starting time. Contactors and thermal relays referenced in the table below are TELEMECANIQUE products. See Square D Digest 7 (March, 000) pages -/7 for contactors. Table : Catalog Numbers for Contactors and Thermal Relays (TELEMECANIQUE) Voltage (Vac) Motors Circuit Breaker Thermal Relay I e max Contactor P (kw) I (A) Type A I rm (A) I q (ka) Type I rth C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA C0L-MA LC-D09 LC-D09 LC-D8 LC-D LC-D LC-D LC-D0 LC-D0 LR D 0 LR D 07 LR D 08 LR D LR D LR D LR D LR D /../../ / /8 7/ / 0/0 I rm (A) = Magnetic release (in amperes) I q (KA) = Interrupting rating (in ka) I rth = Thermal relay current rating 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

26 Section IEC 097- Rated Protection Devices IEC RATED CH-DC CIRCUIT BREAKERS FOR DC CIRCUITS Overview The CH-DC circuit breakers are used in circuits with dc power supplies up to Vdc (-pole) or 7/0 Vdc (-pole). The CH-DC provides protection of circuits against short-circuit currents and overload currents, and is available with ratings from to 0 A. Additionally, it allows manual control or isolation of a dc circuit. These are typically used in applications such as emergency lighting, automatic systems, electrolysis, telephony, etc. Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads. Trip-free mechanism: Contacts cannot be held in the on position when the C0 is tripped automatically. Isolation with positive break indication: Green strip on the operating handle indicates that all poles are open. C curve: Overcurrent protection for all application types. Magnetic release operates between 7 and times ampere rating. Connection Accessories Box lug connections for copper wiring are provided for the CH-DC devices. Remote monitoring and control can be provided with optional NC0 electrical accessories including the OF Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release, and/or MX + OF Shunt Trip. NOTE: The C0 electrical accessories are not compatible with the CH-DC circuit breaker. Standards Compliance with IEC 097- Standards Table : Specifications for IEC Rated CH-DC Circuit Breakers Package size: Two 0. in. (9 mm) modules; 0.7 in. (8 mm) width per pole Voltage (nominal): -pole: 7 Vdc; -pole: 7/0 Vdc High voltage withstand: kv Connection: Box lugtunnel terminals for #8 # AWG ( mm )cables Mounting:.8 in. ( mm) DIN Rail Time-current curves: C curve; Magnetic releases operate between 7 and I n Degree of protection: Case: IP0 Terminals: IP0 as per IEC 9 Rating on connector: Copper wiring only Temperature: Calibration: F (0 C) Storage: -0 to 7 F (-0to80 C) Operating: - to 8 F (-0to70 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) as per IEC 8--0 Number of operating cycles:,000 (O-C) at L/R 0.0 sec. See selection table for weights and interrupting ratings Table : C CurveCH-DC Circuit Breakers -pole -pole Rating (A) -pole Modules MG0 MG0 MG0 MG0 -pole Modules MG0 MG0 MG0 MG MG0 MG0 MG07 MG08 MG0 MG0 MG07 MG08 0 MG09 MG00 MG09 MG00 + or or + + Line Side Feeding Load Side Feeding Line Side Feeding Load Side Feeding Figure : IEC Rated - and -pole CH-DC Circuit Breakers Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

27 Section IEC 097- Rated Protection Devices IEC RATED NC0H CIRCUIT BREAKERS Overview A family of MULTI 9 circuit breakers meeting IEC 097- is available primarily for OEMs wishing to export manufactured products to countries requiring IEC Ratings instead of UL Ratings. They are suitable for protection of cables against overloads and short circuits in equipment. They can also be used for manual control and isolation of circuits. The NC0H circuit breakers are available in B, C, and D trip curves, as listed in the tables with catalog numbers. They include devices ranging from to A. (For lower current ratings, select devices from the C0 series.) Standard Features Fast closing: Allows increased withstand to the high inrush currents of some loads Trip-free mechanism: Contacts cannot be held in the on position when the NC0 is tripped automatically. Isolation with positive break indication: Green strip on operating handle indicates all poles are open. Terminals ensure pull-out withstand of cables, guiding of cables into correct position, and tightening of wide cross-section cables. B curve: Overcurrent protection of very long cables and protection of networks supplied by generators. The magnetic operates between and times ampere rating. C curve: Overcurrent protection for all application types. Magnet release operates between 7 and times ampere rating. The magnetic operates between 7 and times ampere rating. D curve: Overcurrent protection for loads with high inrush currents (motors, transformers). The magnetic release operates between and times ampere rating. Accessories Ground-fault protection can be provided when combined with a VIGI NC0 module. Remote tripping and indication can be provided by adding a variety of auxiliaries (see section for accessories). NOTE: The C0 accessories may not match the NC0 circuit breaker. Table : Specifications for IEC Rated NC-0H Circuit Breakers Package size: Three 0. in. (9 mm) modules;.0 in. (7 mm) width per pole High voltage withstand: kv Maximum voltage rating: 0 Vac Connection: Box lug: 0 A: #8 to # AWG ( 0 mm ) cables Use with copper wire only Mounting:.8 in. ( mm) DIN rail Degree of protection: Case: IP0 as per IEC 09 Terminals: IP0 Time/Current curves: B, C and D curves Temperature: Calibration: 8 F (0 C) Storage: -0 to 7 F (-0to80 C) Operating: - to 8 F (-0to70 C) Tropicalization: Treatment (relative humidity: 9% at F ( C) as per IEC8--0 Number of operating cycles: 00 (O-C) at A 000 (O-C) at 80 A See selection table for weights and interrupting ratings Standards IEC 097-, VDE 00 CE Marked Figure : IEC 097- Rated NC0H -, -, - and -pole Circuit Breakers 0/ Schneider Electric All Rights Reserved 7 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

28 Section IEC 097- Rated Protection Devices Table : IEC Rated NC0H Circuit Breakers Rating (A) B Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules C Curve -pole Modules -pole Modules -pole Modules -pole 8 Modules Rating (A) DCurve -pole Modules -pole Modules -pole Modules -pole 8 Modules Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

29 Section IEC Rated Ground-fault Protection Devices SECTION IEC RATED GROUND-FAULT PROTECTION DEVICES SELECTION TABLE Overview The MULTI 9 System includes four products that provide ground-fault protection per IEC Standards. These products are summarized below and discussed in more detail in the following pages. Table 7: Selection Table for IEC Rated Ground-fault Protection Devices Ratings C0 VIGI DPN-N VIGI ID RCD NC0 VIGI Number of poles -pole -pole -pole -pole Ø + N -pole -pole -pole -pole -pole Rated current (A) 77 F ( C) I n < < < < 0 0 Sensitivities (ma) Instantaneous Selective s 00 s 00 s Yes Yes Yes Yes Yes Yes Yes Yes Voltage (nominal) 0 0 Vac, 0 Vac 0/00 Vac 0 Vac 0 Vac Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Trip Units Time/Current curve Bcurve Ccurve Dcurve Depends on circuit breaker used Yes Yes N/A Depends on circuit breaker used Dimensions (in./mm) Width Height Depth./.9/8.00/7./.9/8.00/7./.9/8.00/7.8/7.9/8.00/7./.9/8.00/7./.9/8.00/7.8/7.9/8.00/7./.9/8.00/7.9/8.9/8.00/7./8.9/8.00/7 Weight (oz./g)./.9/0 < =./80 > = 7./.70/ /0.9/0.8/0 9.7/0.0/70 -pole C0 VIGI Module -pole NC0 VIGI Module DPN-N VIGI Module ID RCD Figure 7: IEC Rated Ground-fault Protection Devices 0/ Schneider Electric All Rights Reserved 9 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

30 Section IEC Rated Ground-fault Protection Devices IEC RATED C0 VIGI MODULES FOR GROUND-FAULT PROTECTION Overview The C0 VIGI residual current detector can be added to the C0 circuit breaker to provide a high level of protection against earth leakage faults. The VIGI module clips onto the right-hand side of a C0 protective device and is mechanically linked to the C0 circuit breaker, which it trips when the VIGI detects residual current. The VIGI module combines a current sensing toroid and residual current relay in one case and operates without an auxiliary power supply source. It may be ordered with a variety of non-adjustable sensitivities ( to,000 ma). A version with time delay (selective) provides additional time discrimination with downstream instantaneous residual current devices. A built-in filtering device prevents nuisance tripping due to transient voltages (lightning, line disturbances, etc.) and transient currents (from high capacitive circuits). VIGI modules are available for use with -, -, and -pole C0 circuit breakers. The VIGI module may be field installed. A visual indicator of the ground fault is provided by a red flag on the VIGI operating handle. A manual test button on the front panel allows manual testing of the VIGI module. The C0 VIGI module can be field-adapted to reset in one of two modes: Automatic reset when the associated protective device handle is reset, or by manually resetting the VIGI prior to reclosing the supplementary protector. NOTE: The C0 version of the VIGI Module cannot be used with the NC0 series. A different series of VIGI Modules is available for the NC0 devices. C0 Circuit Breaker Vigi Module Residual Current Circuit Breaker + = Figure 8: Example Residual Current Circuit Breaker Also see the DPN-N Residual Current Circuit Breakers and ID Residual Current Switches in this catalog. Accessories Terminal screw shields prevent contact with the VIGI module terminal screws. The bag includes twenty pieces of single-pole shields. (Cat. No. 98). Table 8: Specifications for IEC Rated VIGI Modules for Ground-fault Protection Package size: See Table 7 Voltage (nominal): 0 0 Vac, +% -0%, 0/0 Hz; 0 Vac, +% -0%, 0/0 Hz High voltage withstand: kv Connection: Box lug: (copper wire only) Cables: stranded # AWG ( mm ), solid#awg(mm ), stranded # AWG ( mm ), solid#awg(mm ) Mounting:.8 in. ( mm) DIN rail Time-current curves: Depends on circuit breaker Time/current curve: Instantaneous or selective release s Sensitivities: Fixed at, 0, 00, or 00 Temperatures: Calibration: 77 F ( C). Operating: to 0 F (-to0 C) See selection table for weights and interrupting ratings Standards Combined with C0, the vigi module forms a residual current device which conforms to the following standards: IEC 09 EN Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

31 MULTI 9 System Catalog Section IEC Rated Ground-fault Protection Devices Table 9: Catalog Numbers for VIGI C0 ModulesAC Class Rating (A) Voltage (Vac) Sensitivity (ma) -pole Modules -pole Modules -pole 7 Modules -pole 7 Modules s 00 s NOTE: Width of one module = 0. in. (9 mm). -pole C0 VIGI Module -pole C0 VIGI Module -pole C0 VIGI Module T T 7 T 8 Figure 9: IEC Rated -, - and -pole C0 VIGI Modules 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

32 Section IEC Rated Ground-fault Protection Devices IEC RATED NC0 VIGI RESIDUAL CURRENT CIRCUIT BREAKERS Introduction The NC0 VIGI residual current detector can be added to the NC0 circuit breaker to provide a high level of protection against earth leakage faults. The VIGI module clips onto the right-hand side of a NC0 protective device and is mechanically linked to the NC0 circuit breaker, which it trips when the VIGI detects residual current. The VIGI module combines a current sensing toroid and residual current relay in one case and operates without an auxiliary power supply source. It may be ordered with a variety of non-adjustable sensitivities (0 to,000 ma). A version with time delay (selective) provides additional time discrimination with downstream instantaneous residual current devices. VIGI modules complete the NC0 -, - and -pole circuit breakers to provide: Protection of people against indirect contact (per IEC Standards) Additional protection of people against direct contact (0 ma) Protection of electrical installations against insulation faults Table 0: Specifications for IEC Rated NC0 VIGI Residual Current Circuit Breaker The NC0 circuit breaker and VIGI module combination is protected against nuisance tripping due to transient overvoltages such as lightning, switching on the network, etc. Connections: Stranded: 0 A # AWG mm Solid: 0 A # AWG 0 mm Current rating: 0 A Voltage: 0 Vac, +%, -0%, 0/0 Hz The ac class VIGI module guarantees tripping for sinusoidal ac residual currents, either suddenly applied or slowly increasing Total vertical discrimination with the I n 00 ma to A selective sensitivities if it is installed: Upstream from an instantaneous residual current device Downstream from an index II, time-delayed residual current device, where in both cases the I n of the downstream device I n/ of the upstream device s Resetting the NC0 circuit breaker and VIGI module combination in a single operation by resetting the circuit breaker Mechanical indication of the ground-fault is shown on the front face of the VIGI module with a red indicator Instantaneous or selective tripping: Fixed sensitivities for all ratings See selection table for weights and interrupting ratings Standards Complies with IEC 09 Standard Table : Catalog Numbers for NC0 VIGI ModuleAC Class Rating (A) Voltage (Vac) 0 0 Sensitivity (ma) -pole Modules -pole Modules -pole 7 Modules s s NOTE: Width of one module = 0. in. (9 mm) Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

33 Section IEC Rated Ground-fault Protection Devices -pole NC0 Vigi Module -pole NC0 Vigi Module -pole NC0 Vigi Module 080 T T T Figure 0: IEC Rated -, - and -pole NC0 VIGI Modules 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

34 Section IEC Rated Ground-fault Protection Devices DPN-N VIGI RESIDUAL CURRENT CIRCUIT BREAKERS Overview Accessories The DPN-N VIGI Residual Current Circuit Breaker protects against short-circuit and overload as well as earth leakage faults, in one device. It provides overcurrent protection on the phase pole, but switches both the phase and neutral. The DPN-N is available in only one version: with one phase and neutral. This combination must be ordered as an integral product from the factory. BcurveProvides control and protection against overcurrents for very long cables. Magnetic trip units operate between and I n. CcurveProvides control and protection against circuit overcurrents in tertiary and industrial final distribution with TT or TNS grounding systems. Magnetic trip units operate between and I n. These devices may be used in conjunction with the C0 electrical accessories, including the SD Alarm Switch, OF Auxiliary Switch, MN Undervoltage Release, and/or the MX + OF Shunt Trip and Auxiliary Switch. Table : Specifications for IEC Rated DPN-N VIGI Residual Current Circuit Breakers Package size: Four 0. in. (9 mm) modules;. in. ( mm) width Connection: #8 AWG ( mm ) stranded cable # AWG ( mm ) solid cable (copper only) Time-current trip curve: B curve and C curve Operating temperature: to 0 F (-to0 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) as per IEC8--0 Calibration at 8 F (0 C) Degree of protection: Case: IP0 as per IEC 9; Terminals: IP0 Mounting:.8 in. ( mm) DIN rail Number of operating cycles: Mechanical: 0,000 (O-C) Electrical:,000 (O-C) at A See selection table for weights and interrupting ratings Standards IEC 097-, IEC 0898 and IEC 09 CE Marked Catalog Numbers Table : DPN-N VIGI Residual Current Circuit Breaker -pole + N VIGI Residual Current Circuit Breaker Rating (A) -pole + N (B Curve) Modules -pole + N (C Curve) Modules 0 ma 00 ma 0 ma 00 ma 080 N N Figure : IEC Rated DPN-N Residual Current Circuit Breaker Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

35 IEC RATED ID RESIDUAL CURRENT SWITCHES MULTI 9 System Catalog Section IEC Rated Ground-fault Protection Devices Overview The ID Residual Current Switches provide earth leakage protection for electrical circuits, as well as the functions of isolation and switching. ID switches have an electromechanical release that operates without any auxiliary source of supply to open a circuit automatically in the case of an earth leakage or fault between phase and earth greater than, 0, or 00 ma, depending on the model. Models are also available with time-delay. The ID is available in -pole (-phase) and -pole (-phase) versions only. The ground fault is displayed on the front face by a red mechanical indicator. NOTE: The ID residual current switch has only one protective functiondetection of earth leakage current. There is no thermal or magnetic overcurrent protection. Therefore, the circuit must be protected by an upstream circuit breaker or supplementary protector. For combined overcurrent and residual current protection, an alternative is a C0 circuit breaker equipped with an auxiliary VIGI ground-fault detector. The ID device can also be manually operated as a switch. Remote monitoring and control can be provided with optional C0 accessories including the OF Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release, and/or MX + OF Shunt Trip. NOTE: All of these auxiliaries require the use of the OFS Auxiliary Switch (Cat. No. 9) to adapt to the ID Residual Current Switch. Test button: A test button located on the front of the ID Residual Current Switch is provided to allow periodic testing of the device. Table : Catalog Numbers for ID Residual Current SwitchesAC Class Rating (A) Sensitivity (ma) 0 -pole (0 Vac) Modules pole ( Vac) 8 Modules s s s pole ID Residual Current Switch -pole ID Residual Current Switch 0800 N N T R T R N N Figure : IEC Rated - and -pole ID Residual Current Switches 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

36 Section IEC Rated Ground-fault Protection Devices Table : Specifications for IEC Rated ID Residual Current Switches Package size: See Table 7 Voltage (nominal): 0 to Vac, +%, -0%, 0/0 Hz High voltage withstand: kv Connection, box lug: (copper wire only) # AWG ( mm ) stranded cables # AWG (0 mm ) solid cables Sensitivities: Fixed at, 0, or 00 Time/current curve: Instantaneous or selective release S (time delay) Level of immunity: 0 A peak, according to 8/0 ms periodical wave Operating temperature: to 0 F (- to 0 C) Tropicalization: Treatment Relative humidity: 9% at F ( C) per IEC8--0 Mounting:.8 in. ( mm) DIN rail Number of operating cycles (O-C): Electrical: 0,000 See selection table for weights and interrupting ratings Standards IEC 08 EM -008 CE Marked OF Auxiliary Switch and/or SD Alarm Switch MX Shunt Trip and/or MN Undervoltage Release OFS Auxiliary Switch ID Residual Current Switch Figure : Possible Device Combinations Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

37 Section Accessories SECTION ACCESSORIES MULTI 9 C0 AND NC0 ACCESSORIES Overview The MULTI 9 System includes an extensive line of field-installable accessories that enables the system to be used in many applications. Electrical auxiliaries include shunt trip, under-voltage release, auxiliary switch, and alarm switch. Control and display devices include push buttons, motor operators, and signal lamps. Also available is a variety of accessories for locking, operating, shielding, mounting, etc. Other devices include switches and timers. The following diagram shows many of the accessories. NOTE: In many cases, the NC0 series of devices do not use the same accessories as the C0 series. All of the accessories described in this section may be field-installed. These include electrical auxiliaries, comb bus bars, mounting devices, shielding and identification systems, operators, and display, status, and control devices.. DC Circuit Breaker (UL 89A). C0N UL 77 Recognized Supplementary Protectors or UL 89 Listed Circuit Breakers. Undervoltage Release (MN). Shunt Trip (MX + OF). Auxiliary Switch (OF). Alarm Switch (SD) 7. Comb Bus Bar 8. Connector (availability pending) 9. Ring Tongue Terminal Kit. Motor Operator C0N. C0N/NC0 Vigi Module. Terminal Cover. Interphase Barrier. Terminal Screw Shield. Padlock Attachment (Off Position). Plug-in Base 7 Rotary Handle 8. Spacer 9. Identification System A O-OFF A 080 O-OFF O-OFF T or D D D D D D D D D D D D D D D D D D Figure : Overview of MULTI 9 System Accessories 0/ Schneider Electric All Rights Reserved 7 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

38 Section Accessories ELECTRICAL AUXILIARIES Overview The MULTI 9 product line includes a variety of electrical auxiliaries for the C0 and NC0 supplementary protectors and circuit breakers. They may be attached to the protective device as needed to fulfill the tripping or monitoring application requirements. They include the following devices. MN Undervoltage Release MX + OF Shunt Trip and Auxiliary Switch OF Auxiliary Switch SD Alarm Switch TM Motor Control As shown in the figure below, these may be plugged into the base C0 or NC0 protective devices. SD Alarm Switch OF Auxiliary Switch MX + OF Shunt Trip and Auxiliary Switch MN Undervoltage Release C0 Supplementary Protector Figure : Possible Auxiliary Combinations MN Undervoltage Release The MN Undervoltage Release is used to provide remote tripping of C0 or NC0 devices. It causes the device to trip whenever the MN detects a drop of its control voltage to the range of 70 to % of nominal. The tripped condition is shown by a red indicator flag on the front panel of the MN undervoltage release. The MN undervoltage release is mechanically linked to the C0 or NC0 device. It may be used in conjunction with the SD Alarm Switch, OF Auxiliary Switch, and/or the MX + OF Shunt Trip and Auxiliary Switch. NOTE: The tripped circuit breaker or supplementary protector must be manually reset. The MN Undervoltage Trip prevents the device from being reclosed until the control voltage has been restored. 080 D D u > L or + Figure : IEC Rated MN Undervoltage Release N or Models must be selected depending on the level of control voltage source (ac or dc). Used for emergency stop via push button. Used as safety feature on circuit supplying several machines, to prevent uncontrolled restarting of motors. UL Recognized for UL 77. Call Square D Field Office for availability of UL acceptance for use with UL 89 Listed devices. CSA and IEC Rated The linkage is mechanical, thus ensuring the integrity of the protection function. Multiple auxiliaries may be used in combination with a single C0 protective device. NOTE: The MULTI 9 VIGI Module, which adds ground-fault protection, is described in Section of this catalog. Terminal pads for connection of control wiring are provided for either two # AWG (. mm )cables, or one # AWG (. mm ) cable Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

39 Section Accessories MN s Time-delayed Undervoltage Release The time-delayed undervoltage release is identical to the standard MN undervoltage release, except that it allows brief interruptions of control power without opening the circuit breaker due to undervoltage. It allows a 0. second time delay before opening the associated protective device. IEC Rated; not UL Recognized Table : Power Consumption of MX and MN Accessories Type Voltage VA or W MX (inrush) MN (holding) Vac 0 0 Vac 8 0 Vac 0 Vdc 8 Vac/Vdc Vac/Vdc 0 0 Vac 8 Vac 8 Vdc MN s (holding) 0 0 Vac. MX + OF Shunt Trip and Auxiliary Switch OF Auxiliary Switch The MX + OF switch combines the functions of shunt trip and auxiliary switch into one device. The MX Shunt Trip, when energized by a control voltage, provides remote tripping of the associated C0 circuit breaker or supplementary protector to which it is mechanically linked. The tripped condition is indicated by a red indicator flag on the front panel of the MX + OF. The protective device must be manually reset after being tripped by the MX. NOTE: When the OF function is combined with the MX Shunt Trip, no test button is provided. The MX + OF Switch may be used in conjunction with the SD Alarm Switch, which presents the trip status, and/or the MN Undervoltage Release. UL Recognized for UL 77. Call Square D Field Office for availability of UL acceptance for use with UL 89 Listed devices. CSA and IEC Rated. The OF Auxiliary Switch communicates the OPEN or CLOSED status of the associated C0 circuit breaker or supplementary protector via auxiliary contacts. It is mechanically linked to the supplementary protector. (see the SD Alarm Switch for TRIP status. It may be used in conjunction with the SD Alarm Switch, which presents the trip status, and the MN Undervoltage Release. It would not normally be used with the MX + OF Shunt Trip because that device already includes the OF function. UL Recognized for UL 77. Call Square D Field Office for availability of UL acceptance for use with UL 89 Listed devices. CSA and IEC Rated C Closed Open U> C L or + N or Figure 7: UL Recognized MX + OF Auxiliary Switch 0808 Closed Open L or + N or Figure 8: UL Recognized OF Auxiliary Switch 0/ Schneider Electric All Rights Reserved 9 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

40 Section Accessories SD Alarm Switch The SD Alarm Switch communicates the TRIP status of the associated C0 or NC0 circuit breakers or supplemental protectors via auxiliary contacts. It is mechanically linked to the protective device. (Use the OF Auxiliary Switch for OPEN or CLOSED status.) Locally, it also indicates the TRIPPED-ON-FAULT condition of the protective device with a red indicator flag on the front panel. A test switch allows simulation of the SD function without operating the protective device. The SD Alarm Switch is reset when the associated protective device is reset, or it may by reset independently of the protective device with a reset lever on its front panel. The SD Alarm Switch may show the circuit breaker status, using V Type Signal Lamps, other annunciators, or a control system. It may be used in conjunction with the OF Auxiliary Switch which presents the OPEN or CLOSED status, the MN Undervoltage Release, and/or the MX + OF Shunt Trip. UL Recognized for UL 77. Call Square D Field Office for availability of UL acceptance for use with UL 89 Listed devices. CSA and IEC Rated 0809 Table 7: SD and OF Alarm Switch Ratings Voltage 77 Vac <0Vac 0 Vac <8Vdc <Vdc Breaking Capacity (A) SD OF Table 8: Catalog Numbers for Electrical Auxiliaries 9 9 Fault Normal 9 L or + N or Figure 9: UL Recognized SD Alarm Switch Device MX + OF shunt trip MN undervoltage release Instantaneous Time delayed Control Voltage Width in C0 NC0 Vac Vdc Modules UL/IEC IEC UL/IEC IEC MG97 MG97 MG97 MG9 MG97 MG9 MG98 MG MG70 MG79 MG78 MG7 MG OF auxiliary switch MG9 9 MG7 7 SD alarm switch MG98 97 MG7 7 MX + OF Shunt Trip MN Undervoltage Release OF Auxiliary Switch SD Alarm Switch U > U < C C D D Figure 0: Electrical Auxiliary Schematics Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

41 Section Accessories TM Motor Operator The TM Motor Operator modules allow remote operation of C0 circuit breakers and supplementary protectors. The TM is mechanically linked to the protective device via its handle. This handle can also be used to manually operate the TM and its associated protective device. The presence of a control voltage in the TM causes the closing of the circuit breaker poles; when this voltage is interrupted, the poles open. A red indicator is displayed when the TM Motor Operator is energized or being opened; the indicator is gray when it is not energized or is completely opened. A selector switch on the TM front panel is used to disconnect the motor operator or place it in the AUTO (operational) mode. The open position frees an integral padlocking device to allow physical lockout. (Required 0.8 in. [7 mm] dia. padlock, not included.) NOTE: Reclosing after a fault should primarily be carried out locally and in manual mode after verification and clearance of the fault. The use of an SD Alarm Switch, wired in series with the control line of the TM Motor Operator, prevents automatic and remote reclosing. The C0 protective device may be manually operated via its handle, even with the TM installed. The TM Motor Operator may also be used in conjunction with the OF Auxiliary Switch to give the OPEN or CLOSED status of the protective device. IEC Rated; not UL Recognized Table 9: IEC Rated C0 TM Motor Operators Description US No. IEC No TM Remote motor control for C0 -pole or -pole TM Remote motor control for C0 -pole or -pole MG8 8 MG8 8 Figure : IEC Rated C0 TM Motor Operators Table 0: Specifications for IEC Rated C0 TM Motor Operators Voltage: 0 Vac (-%, +%) Frequency: 0/0 Hz Response to undervoltage: Mechanical opening of poles (>0. sec.) Reclosing two seconds after power is restored Insensitive to short-supply interruptions (<0. sec.) Opening time of associated circuit breaker: 0. sec. by TM motor operator 0.0 sec. by shunt trip or undervoltage release Rate of operation: seconds max. up to operations per day Width: 7 modules:. in. ( mm) Closing time: Two seconds Power consumption: Inrush 8 VA HoldingVA Status indication: Mechanical indicator flag Number of operating cycles (O-C): 0,000 for TM motor operator/c0 circuit breaker combination at F (0 C) Terminals: Tunnel terminals are suitable for # AWG ( mm )cables 080 ON OFF Auto s s t(s) Figure : Closing Times 0800 A M L 0800 SD A Auto 0 V C0 -pole and -pole 0800 SD A Auto 0 V C0 -pole and -pole A OF OF N Figure : IEC Rated TM Motor Operator Schematics A A 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

42 Section Accessories UL Recognized C0 Comb Bus Bars A Comb Bus Bar can be used to provide common service to a number of MULTI 9 supplementary protectors and accessories. This eliminates the hassle of providing discrete wiring to a number of protective devices operating from one power source. It is available in 0.7 in. (8 mm) pole spacings for the C0 series. It meets the UL 77 requirements. These are available in -, -, or -phase (conductor) models, and can be purchased in -pole lengths. Field wiring may be applied directly to the comb bus bar by inserting both the conductor and the tooth of the comb into the same box lug connector of the C0N supplementary protector. Refer also to the connector and tooth cap accessories for the comb bus bar. Rated insulation voltage: 80Y/77 Vac Rated current: A service single-feed Available in -, -, or -phases (conductors) Distance between outgoing poles: 0.7 in. (8 mm) Lengths: Fixed length of poles (Consult Square D field office for other sizes.) Connection: Comb tooth and main feed wire connect to box lug of UL 77 C0N supplementary protector UL Recognized (for use with UL 77 devices only; not CSA Rated) Figure : UL Recognized C0 -phase Comb Bus Bar Table : Catalog Numbers for UL Recognized C0 Comb Bus Bars Description Length Type Cat. No. -pole comb bus bar 8. in. ( mm) -phase -phase -phase MG8 MG8 MG87 Connectors Optional connectors are provided for connecting field wiring to a comb bus bar. They accept up to # AWG wiring. Two versions are available: one to provide horizontal feed and the other to provide vertical feed of the wiring. (Alternately, up to mm cable may be installed in the same box lug terminal of the C0N device as the comb tooth.) UL Recognized for UL 77. Call Square D Field Office for availability of UL acceptance for use with UL 89 Listed devices. Table : C0 Connectors Description Wire Size Horizontal Vertical Vertical Connector Horizontal Connector Connector # AWG ( mm ) # AWG (0 mm ) Figure : UL Recognized C0 Connectors Tooth Caps The Tooth Caps may be slipped onto the unused teeth of the Comb Bus Bar. They come in strips with -pole spacing, but can be snapped apart to be used individually. Table : UL Recognized Tooth Caps Description Tooth caps for 0.7 in. (8 mm) comb bus bar (0 pieces) Cat. No. 088 Figure : UL Recognized C0 Tooth Caps Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

43 Section Accessories DEVICE SHIELDING Spacer The Spacer clips onto a DIN rail to occupy the space of one 0. in. (9 mm) module. It can be used to provide space for future protective devices and accessories. It may also be used to provide a ventilation gap to prevent overheating. IEC Rated; not UL Recognized Table : IEC Rated DIN Rail Spacer Description Width US No. IEC No. Spacer for IEC Rated C0 and NC0 circuit breakers 0. in. (9 mm) MG70 70 Figure 7: IEC Rated DIN Rail Spacer Interphase Barriers The Interphase Barriers snap onto the top and bottom of the C0 devices to provide increased isolation distance between two adjacent connectors. NOTE: These are not needed with the versions of C0 with UL 89 Rating nor with the Ring Lug Terminal kit, since the UL 89 circuit breakers already include increased isolation barriers. IEC Rated; not UL Recognized Table : IEC Rated Interphase Barrier Description Quantity US No. IEC No. Interphase barriers for C0 circuit breakers pieces MG Figure 8: IEC Rated C0 Interphase Barrier Terminal Screw Shields The Terminal Screw Shield snaps onto the front of the C0N protective devices to provide greater insulation of the terminal screws. IEC Rated; not UL Recognized Table : IEC Rated Terminal Screw Shields Description Device Quantity US No. IEC No. C0 Bag of MG98 Terminal screw shield NC0 Bag of 87 C0 VIGI 98 Figure 9: IEC Rated Terminal Screw Shield Terminal Covers The Terminal Covers completely cover the terminals, either standard or screw-type connectors. They make the use of the interphase barriers unnecessary (and impossible). UL 77 Recognized IEC Rated Table 7: UL Recognized and IEC Rated Terminal Covers Description Device Size US No. IEC No. Terminal cover C0 -pole -pole -pole -pole MG97 MG97 MG97 + MG97 MG Terminal cover NC0 -pole -pole -pole -pole MG97 MG97 MG97 + MG97 MG Figure 0: IEC Rated Terminal Covers 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

44 Section Accessories Ring Lug Terminal Kit The Ring Lug Terminal kit provides isolation barriers and ring terminals to convert a standard box lug UL 77 Recognized C0 supplementary protector to allow front or rear connection with ring type terminals. The kit allows a UL 77 Recognized C0N device to retain its rating. It cannot be field-installed on a UL 89 Listed C0 product. These are user-installed. The Interphase Barriers (or Terminal Covers) cannot be used in conjunction with these Isolation Barriers. Table 8: UL Recognized Ring Lug Terminal Kit Description Quantity Cat. No. Ring Lug Term. Kit Photo Figure : UL Recognized Ring Lug Terminal Kit Ring lug terminal kit Two ring tongue terminals Two isolation shrouds Two 0.0 in. ( mm) screws 700 IDENTIFICATION SYSTEM Snap-on Marking Symbols The Identification System provides marking symbols which can be used on the C0 and NC0 devices. They provide pre-labeled, snap-on plastic clips with one character each. They mount just below the toggle on the C0 devices. The following symbols are available: Blank, 0-9, +, -, and A-Z. NOTE: Note: These are same as markers for Telemecanique AB terminal blocks. IEC Rated; not UL Recognized Table 9: Snap-on Marking Symbols Marking Quantity Cat. No. Marking Quantity Cat. No. A B C D Bag of Bag of Bag of Bag of ABGA ABGB ABGC ABGD Bag of Bag of Bag of Bag of ABR ABR ABR ABR E F G H Bag of Bag of Bag of Bag of ABGE ABGF ABGG ABGH 7 8 Bag of Bag of Bag of Bag of ABR ABR ABR7 ABR8 I J K L Bag of Bag of Bag of Bag of ABGI ABGJ ABGK ABGL Bag of Bag of Bag of Bag of Bag of ABR9 ABR0 ABR ABR ABR M N O P Bag of Bag of Bag of Bag of ABGM ABGN ABGO ABGP Blank Bag of ABRV Figure : IEC Rated Snap-on Marking Symbols Q R S T Bag of Bag of Bag of Bag of ABGQ ABGR ABGS ABGT U V W X Bag of Bag of Bag of Bag of ABGU ABGV ABGW ABGX Y Z Bag of Bag of ABGY ABGZ Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

45 Section Accessories OPERATION DEVICES Rotary Handles A C0 or NC0 protection device with -, -, or -poles can be equipped with a Rotary Handle with an extension to allow operation of the circuit breaker from either the front or the side (lateral) from the outside of a panel. The handle requires that an operating subassembly be affixed to the supplementary protector or circuit breaker. This subassembly can be configured in two ways: For front operation For lateral operation Two versions of the rotary handle are available: The first is a fixed handle for front or lateral mounting on a fixed panel. The second is a draw-out extended handle which may be mounted on a door or hinged panel. It mates with the operating subassembly as the door is closed. IEC Rated; not UL Recognized Table 0: IEC Rated Rotary Handles Figure : IEC Rated Rotary Handle Description US No. IEC No. Operating subassembly for C0 or NC0 protection device (fixed to protection device) MG70 70 Drawout extended handle (mounted on door or hinged panel) MG Fixed handle front or lateral (mounted on fixed panel) MG Padlock Attachments The Padlock Attachment clips onto the face of the C0N device to prevent the handle from being operated. It cannot be installed or removed when padlocked. No tools are needed to install it. The Padlock Attachment allows the IEC C0 circuit breaker to be locked in either the ON or the OFF position (UL 89 Listed and UL 77 Recognized devices can lock in the OFF position only). The padlock attachment accepts a 0. in. (8 mm) diameter padlock, which is not supplied. The front plate or functional door can be opened with the circuit breaker locked in the OFF position. NOTE: Locking the C0 or NC0 in the ON position will not prevent the device from tripping under overcurrent or ground fault conditions. IEC Rated; not UL Recognized Table : IEC Rated Padlock Attachments Figure : Padlock Attachment Description Quantity US No. IEC No. Padlock attachment for C0 protection device Bag of MG Padlock attachment for NC0 protection device Bag of MG7 7 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

46 Section Accessories MOUNTING ACCESSORIES Plug-in Base The Plug-in Base allows permanent field wiring connections to be made to the base, so that a C0 device can be plugged in or removed without affecting field wiring. The Plug-in Base kit includes spade connectors which must be installed on the circuit breaker so it will mate with the Plug-in Base. The Plug-in Base provides no-load isolation of a circuit protected by C0 supplementary protectors. While the circuit breaker is removed, the base can be locked using a 0. in. (8 mm) dia. padlock (not provided). Height of base: 7.0 in. (78 mm); with terminal cover extended, 9. in. (7 mm) Allow minimum center spacing of 7.87 in. (00 mm) between two rows of bases Multiple bases may be used for multi-pole devices IEC Rated; not UL Recognized Table : IEC Rated Plug-in Base Description US No. IEC No. Plug-in base for C0 devices MG99 99 Figure : IEC Rated Plug-in Base Front Mounting Bracket (Kit) The Front Mounting Bracket provides a convenient way to mount MULTI 9 circuit breakers, supplementary protectors or accessories. Its height is equal to a.8 in. ( mm) DIN rail, and allows the C0 and NC0 devices to be clipped onto it in a standard manner. Its width is available for -, -, -, or -pole devices. UL Recognized and IEC Rated Table : Front Mounting Bracket Description Size Cat. No. Front mounting bracket for C0 protective devices Front mounting bracket for NC0 protective devices -pole -pole -pole -pole -pole -pole -pole -pole See dimensional drawings in Section 7. Figure : Front Mounting Bracket Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

47 Section Accessories MSC Mounting Base The MULTI 9 MSC Mounting Base is an integral package that provides DIN mounting of MULTI 9 devices and provides either a -phase or -phase bus bar for up to poles (in two rows) of C0 devices and accessories. The base is rugged, gloss-white, zinc annealed sheet steel with two rows of DIN mounting rails. The heavy-duty base plate allows surface mounting. The single-piece copper bus conductors are insulated and color-coded. Power may be supplied by a reverse-fed C0 circuit breaker, or via the feed-through connections at each end of the bus. Rating: Up to 0 A service Insulation voltage: 90 Vac Current withstand: Peak:. ka Short-time: ka for 0. sec. Phases are color-coded Width: Base 8. in. ( mm); see Table for length Tested to Australian AS9- and AS9- standards IEC Rated; not UL Recognized NOTE: The MSC mounting bases listed below can be used with C0 protection devices. Table : IEC Rated MSC Mounting Base Type Size No. of Poles MSCDCforC0protectiondevices (black, red) MSC 8 for C0 protection devices (red, white, blue) MSC 7 for NC0 protection devices (red, white, blue) * For overall length, add approximately in. (7 mm). -phase -phase -phase Base Length* (in./mm)./.7/ 7.7/8././ 8.8/8 9.7/./ 9./ Cat. No. DC DC DC Figure 7: IEC Rated MSC Mounting Base 0/ Schneider Electric All Rights Reserved 7 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

48 Section Accessories Multi-pole Front Mounting Kit The Multi-pole Front Mounting Kit consists of a transparent, hinged, weatherproof cover with a DIN rail. It allows installation of up to twenty modules of MULTI 9 supplementary protectors and accessories. A DIN rail support is also available. Degree of protection as per IEC 9: IP Dimensions (w x h x d): 9. x.9 x. in. ( x x mm) Cutout dimensions: 7. x.78 in. (8 x 9 mm) IEC Rated; not UL Recognized Table : IEC Rated Multi-pole Front Mounting Kit Description Multi-pole front mounting kit with transparent hinged cover (Includes a -module divisible blanking plate and mounting template) Cat. No. DIN-rail support 0808 Figure 8: IEC Rated Multi-pole Front Mounting Kit Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

49 Section Additional System Devices SECTION ADDITIONAL SYSTEM DEVICES OVERVIEW In addition to the C0 and NC0 Circuit Breakers and Supplementary Protectors which form the heart of the MULTI 9 product line, there are a variety of other devices which may be used with C0 or NC0 devices or as stand-alone devices. These include the following: CM Selector Switches (Change-over) I Isolating Switches OFS Auxiliary Switch Adapter (for IEC CH-DC and ID RCCB devices only) All of these devices adhere to the MULTI 9 packaging format, and can be mounted on a DIN rail in the protection and control cabinet. CM Selector Switches The CM Selector Switch allows manual selection of circuits. Different models are available to allow selection of two or three positions (including off) for one or two circuits. They have maximum ratings of 0 A and 0 Vac. This device may be installed on the DIN rail adjacent to the C0 device and its accessories or remotely in a user interface panel. IEC Rated; not UL Recognized Table : IEC Rated CM Selector Switches CM Selector Switch Type No. of Circuits No. of Positions Width in Modules Cat. No. 080 Figure 9: CM Selector Switch Two Position Green N 080 Three Position Green N 0 9 L Red L Red 8 Load Figure 0: CM Selector Switch Schematics Load 0 8 0/ Schneider Electric All Rights Reserved 9 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

50 Section Additional System Devices I Isolating Switch The I Isolating Switch provides manual on-load opening or closing of a circuit. Note that it does not provide either thermal or magnetic protection. It can be used with the OF auxiliary switch and with other non-electrical accessories in the C0 family. This device may be installed on the DIN rail adjacent to the C0 device and its accessories or remotely in a user interface panel. Table 7: IEC Rated I Isolating Switches Rating (A) -pole (0 Vac) Modules -pole ( Vac) Modules -pole (0 Vac) Modules -pole ( Vac) Modules -pole (0 Vac) Modules -pole ( Vac) Modules -pole (0 Vac) 8 Modules Figure : -, -, - and -pole I Switches OFS Auxiliary Switch Adapter (for ID RCD) The OFS Auxiliary Switch Adapter allows the ID Residual Current Switches to use the same electrical accessories as the C0 supplementary protectors, including the OF Auxiliary Switch, SD Alarm Switch, MN Undervoltage Release, and/or MX + OF Shunt Trip. IEC Rated; not UL Recognized Table 8: OFS Auxiliary Switch Description Cat. No. OFS auxiliary switch Figure : OFS Auxiliary Switch Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

51 Section Additional System Devices STATUS, DISPLAY AND CONTROL ACCESSORIES There are a variety of other accessories which may be used with the C0 or NC0 devices to communicate control and/or status information. These include the following: V Type Signal Lamps BP Push Buttons CH Hour Counter CI Impulse Counter IH and IHP Time Switches These accessories may be located adjacent to the C0 or NC0 or may be located remotely. V Signal Lamps The V Type Signal Lamp indicates when voltage is applied to a circuit and may be used with MULTI 9 circuit protection systems or other applications. The lenses are available in a variety of colors. Bulbs are available for 0 Vac and,, or 8 Vac/Vdc operation. This accessory device may be installed on the DIN rail adjacent to the C0 devices and its accessories or remotely in a user interface panel. IEC Rated; not UL Recognized Table 9: IEC Rated V Signal Lamps and Accessories Type Width in Modules Complete V signal lamp 0 Vac V signal lamp without bulb or lens Accessories Lens (bag of ) Bulbs (bag of ) Voltage Color Cat. No. Clear Red Green Yellow Blue Vac 8 Vac/Vdc Vac/Vdc Vac/Vdc Clear Red Green Yellow Blue Clear, red, yellow () Blue, green () All All All Figure : IEC Rated V Signal Lamps () According to lens color. BP Push Buttons The BP Push Button device may be used to control MULTI 9 circuit protection systems or other equipment. It provides momentary switching and is available with one N.O., one N.C., or combined with one each N.O. + N.C. contact. It is available with or without a signal lamp, which is available in a variety of colors. This device may be installed on the DIN rail adjacent to the C0 and its accessories or remotely in a user interface panel. IEC Rated; not UL Recognized Push Buttons without Signal Lamps Figure : IEC Rated BP Push Buttons Push Buttons with Signal Lamps 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

52 Section Additional System Devices Table 0: Catalog Numbers for BP Push Buttons Type Type Width (In Modules) Voltage Signal Lamp Color Push Button Color Cat. No. Push buttons without signal lamps O+C C O Gray Red Green 7 Push buttons with signal lamps C O Red Green Red Green 8 Bulb (bag of ten) 0 Vac 8 Vac/Vdc Vac/Vdc Vac/Vdc Green Red All All All Lens (bag of five) Green Red 0809 Push Buttons without Signal Lamps Push Buttons with Signal Lamps O + C C O C O x x x Figure : IEC Rated BP Push Button Types x CH Hour Counter The CH Hour Counter is used for measuring the total operating time of a circuit or load. It is capable of counting to a maximum of 99, hours. It operates on 0 Vac, 0 Hz. The CH must be installed downstream of a circuit breaker or supplementary protector. 080 The CH Hour Counter is useful for metering of activity or for scheduling maintenance. This device may be installed on the DIN rail adjacent to the C0 and its accessories or remotely in a user interface panel. IEC Rated; not UL Recognized Load Figure : IEC Rated CH Hour Counter CH CI Impulse Counter The CI Impulse Counter is an electromechanical counter designed to measure impulses produced by various devices. It displays the running total of metered impulses. The CI Impulse Counter is unaffected by interruptions in the main power supply. 080 It is most suitable for counting impulses emitted by detectors such as kilowatt-hour metering, temperature overrun, etc. This device may be installed on the DIN rail adjacent to the C0 device and its accessories or remotely in a user interface panel. N L N L IEC Rated; Not UL Recognized Table : CH Hour Counter and CI Impulse Counter CI CI Type Voltage (Vac) Frequency (% to +%) Width in Modules Cat. No. CH Hz 0 CI 0 0 0/0 Hz Load Kilowatt Meter (Wh) Load Figure 7: IEC Rated CI Impulse Counter Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

53 Section Additional System Devices IH and IHP Time Switches The IH and IHP Time Switches control the opening and closing of one or more separate circuits according to the programming set by the user. The sequences are repeated daily ( hour) or weekly (7 day), depending on the model. Their compact dimensions, 0.7 in. (8 mm) width, makes them ideal for small enclosures. They may be used to control heating, lighting, watering, or other cyclic processes. IH Time Switch IHP Time Switch Figure 8: IEC Rated Time Switches Table : IH and IHP Time Switch Specifications A -way manual selector switch may be set in ON, AUTO, or OFF positions The IH models are set up using plug-on jumpers; the IHP is programmable through the front panel Accuracy: ± s per day at 8 F (0 C); quartz time base Contact Rating: A, 0 Vac, (cos φ = 0.) Connection: Tunnel terminals for cables up to # AWG ( mm ) Consumption:. VA Ambient temperature: to F (-to0 C) Complies with Standard EN 070 IEC Rated UL Recognized for 9 (approval in process) Table : Catalog Numbers for IH and IHP Time Switches Type Time switch (IH) Cycle Period Min. Time Between Operations No. of Channels Voltage Frequency Battery Max. No. of Switching Operations Standards Cat. No. 7 days hrs. 0 Vac ±% 0/0 Hz Yes on, off IEC hrs min. 0 Vac ±% 0/0 Hz Yes 8 on, 8 off IEC hrs min. 0 Vac ±% 0/0 Hz No 8 on, 8 off IEC hrs min. Vac ±% 0/0 Hz Yes 8 on, 8 off UL 9 Programmable 7 days min. Vac ±% 0/0 Hz Yes 8 on, 8 off UL 80 time switch (IHP) 7 days min. Vac ±% 0/0 Hz Yes on, off UL 8 Jumpers for IH time switch ( each of red, green, white and yellow) 0/ Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

54 Section Additional System Devices MINI PRAGMA DIN TYPE ENCLOSURES Applications Extension enclosure for individual and institutional housing Subdistribution enclosure in service sector buildings Rated current: A 0809 Standard Features Material: Insulating, self-extinguishing material White color Standards: International IEC 9. French NF C.9 Degree of protection: IP 0 as per IEC 9 Figure 9: Mini PRAGMA DIN Type Mechanical impacts: IK 07 as per EN 0. Enclosures Class : Total insulation Behavior in fire and abnormal heat as in IEC 9.. in accordance with ERP and IGH (high-rise building) regulations Construction Back with a central hole to simplify installation and two oblong holes for leveling. Punch-out holes on the top, bottom and back surfaces enable cable insertion throughout. Axis placed on the back/front panel parting line ensures easy, neat punch-outs using pliers. Metal rail centered at mid-height, and sufficiently far from the back to enable wire insertion Rigid, sealable, front panel Plain or transparent, rounded and flush door A key lock is optional Table : Enclosures (one row with transparent door) Number of 0. in. (9 mm) Modules 8 Dimensions (in./mm) H L D 7.9/0 7.9/0 7.9/0 7.9/0./.8/8 7./8.0/.70/9.70/9.70/9.70/9 Cat. No Accessories Sloping terminal block support to simplify cable insertion and improve accessibility on clamping Terminal block equipped with guides to simplify cable introduction in tunnels Four holes for - and -module enclosures: () x 0.0 sq. in. ( mm )+ () x 0.0 sq. in. ( mm ) Eight holes for 8- and -module enclosures: () x 0.0 sq. in. ( mm )+ () x 0.0 sq. in. ( mm ) Built-in divisible blanking plate: Two modules Identification strip Four sealing plugs for wall fastening screws (essential for Class ) Table : Mini PRAGMA Accessories Accessory Sealing kit Key lock Extra terminal block for ground or neutral Ten extra blanking plates dividable per module of 0. in. (9 mm) Cat. No Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

55 Section Additional System Devices MINI PRAGMA WEATHERPROOF TYPE ENCLOSURES Applications Extension enclosure for service sector and industrial buildings Subdistribution enclosure for distribution Installation for harsh or humid environments (farm buildings, sawmills, garages, etc.) Standard Features Material: Insulating, self-extinguishing material Light grey color Standards: International IEC 9. French NF C.9 Degree of protection as per IEC 9: IP Degree of protection against mechanical impacts as per EN 0.: IK 07 Class : Total insulation Fire withstand capacity: 8 F(70 C) Construction Back with a central hole to simplify installation and two oblong holes for leveling. Punch-out holes on the four side surfaces and back enables cable insertion throughout. Axis placed on the back/front panel parting line ensures easy, neat punch-outs using pliers Metal rail removed from the back to allow the wires to pass through Rigid, sealable front panel Transparent, rounded and flush door A key lock is optional Table : Enclosures (one row) Modules 0. in. (9 mm) 8 Dimensions (in./mm) H L D 7.0/00 7.0/00 7.0/00 7.0/00 7.0/00 Accessories Included.70/././9.88/9 9./7.9/.9/.9/.9/.9/ Cat. No Sloping terminal block support to simplify cable insertion and improve accessibility Figure 0: Mini PRAGMA Weatherproof on clamping Type Enclosures Terminal block equipped with guides to simplify cable introduction in tunnels Four holes for -, - and -module enclosures: () x 0.0 in. sq. ( mm )+ () x 0.0 in. sq. ( mm ) Eight holes for 8- and -module enclosures: () x 0.0 in. sq. ( mm )+ () x 0.0 in. sq. ( mm ) Built-in divisible blanking plate: Two modules Identification strip Four sealing plugs for wall fastening screws (essential for Class ) Table 7: Accessories for Mini PRAGMA Weatherproof Type Enclosures 0809 Accessory Type Sealing kit Key lock Extra terminal block for ground or neutral Ten extra blanking plates divisible per module of 0. in. (9 mm) Cat. No / Schneider Electric All Rights Reserved Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

56 Section Additional System Devices PRAGMA F DIN TYPE ENCLOSURES Applications Indoor enclosures Creation of subdistribution boards for small and medium service sector buildings (hotels, offices, shops) and switchboards for medium and large residential installations Switchboard rated current: 0 A Standard Features Material: Metal back, ivory color Standards: International IEC 9., French NF C.9 Degree of protection against mechanical impacts as per IEC 9: Enclosure without door: IP 0 Enclosure with door: IP D Degree of protection against mechanical shocks as in EN 0 : IK 08 Insulation: Class : Standard Class : Total insulation Fire and abnormal heat withstand in accordance with regulations for buildings open to the public (BOP) and high-rise buildings (HRB) 0809 Figure : PRAGMA F DIN Type Enclosures Composition Metal back (fully insulated for Class enclosures), with removable chassis One insulated front panel frame Insulated modular front plates Insulated plates with knockouts Accessories Included One ground/neutral () 0-hole terminal blocks: () x 0.0 in. sq. ( mm )+ () x 0.0 in. sq. ( mm )+ () x 0.0 in. sq. ( mm ) Terminal block equipped with guides to simplify cable introduction in tunnels Eight module divisible blanking plates: Two blanking plates for one, two and three row enclosures Four blanking plates for four, five and six row enclosures Label with protective cover for each row Table 8: PRAGMA F Type Enclosures Rows Number of Modules Dimensions (in./mm) 0. in. (9 mm) 0.7 in. (8 mm) H W D /00 7.7/0./00 9./70./900./0./0./0./0./0./0./0.9/70.9/70.9/70.9/70.9/70.9/70 Cat. No Schneider Electric All Rights Reserved 0/0 Courtesy of Steven Engineering, Inc.! 0 Ryan Way, South San Francisco, CA ! Main Office: (0) ! Outside Local Area: (800) 8-900!

MULTI 9 System Catalog

MULTI 9 System Catalog MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

Multi 9 System Catalog

Multi 9 System Catalog Multi 9 System Catalog Catalog 0860CT00 R07/4 04 Class 860 CONTENTS CONTENTS Description............................................. Page Description Page Introduction..................................................7

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

WMS SUPPLEMENTARY PROTECTORS

WMS SUPPLEMENTARY PROTECTORS WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ) Catalog Class 0CT00R/0 0 CONTENTS Description..............................................Page Description.............................................

More information

Introduction Circuit Protection

Introduction Circuit Protection Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

C60 UL 489 / CSA C22.2 No IEC / GB

C60 UL 489 / CSA C22.2 No IEC / GB Main functions of UL 89 circuit breaker: b protection of circuits against: v short circuit currents v overload currents b control b isolation Various applications: b semi-conductors b electronic machinary

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Supplemental Protectors

Supplemental Protectors compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are

More information

Product Guide. UL 489 DIN rail miniature circuit breakers

Product Guide. UL 489 DIN rail miniature circuit breakers Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 262816 - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

C60 multi-standard range

C60 multi-standard range Low voltage C60 multi-standard range Catalogue 07/2014 C60 multi-standard range Summary Presentation Panorama of the C60 multi-standard range CM907017E 2 Circuit protection Circuit breaker C60 UL 489

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Time Delay Values (E-Series)

Time Delay Values (E-Series) Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

Control Circuit and Load Protection Products

Control Circuit and Load Protection Products Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)

C60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu) DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description

C C CIRCUIT-BREAKERS Moulded-case (MCCB), general. 1. Introduction. 2. General description CIRCUIT-BREAKERS C C81-21 CIRCUIT-BREAKERS - Contents 1. Introduction 2. General description 3. Rated voltages 3.1 Rated operational voltage (U e ) 3.2 Rated impulse withstand voltage (U imp ) 3.3 Rated

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP

Bulletin 1492-MC 1492-MCGA, -MCEA 1492-SP Bulletin Control Circuit and Load Protection Product Overview Bulletin -MC -MCGA, -MCEA -SP Type Branch Ground Fault Detection Features /V, V & Y/V rating A interrupt / in. per pole wide... A @ UL Circuit

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers

More information

Supplementary Circuit Protectors Type GSB63

Supplementary Circuit Protectors Type GSB63 Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Miniature Circuit Breakers

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery

More information

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet Specification sheet PLT Breaker-based transfer switch open, closed or soft transition 800 3000 amps Description PLT breaker-based transfer switches are designed for operation and switching of electrical

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns

Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Ground Fault Current Protection Devices Prevent Costly Production Shutdowns Figure.1 Altech s three new series deliver multiple capabilities. In all three series, ground fault sensitivity levels range

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

The right solution for every home

The right solution for every home Domae Household switchboards The right solution for every home Household guide 2002 Building a New Electric World. Household switchboards Domae The right solution for every home Household guide 2002 Building

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

Surgelogic Surge Protective Devices LC, XR, and XW Series

Surgelogic Surge Protective Devices LC, XR, and XW Series Surgelogic Surge Protective Devices LC, XR, and XW Series Catalog 1311CT0101R6/07 2007 Class 1311 CONTENTS Description..............................................Page Product Description...........................................

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS SECTION 26 28 16 (16410) - ENCLOSED SWITCHES AND CIRCUIT BREAKERS PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Individually Mounted Switches and Circuit Breakers Used for the following: a. Service

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC Switching Power Supply DIN-Rail Mount Power Supply With Capacity Up to 240 W for General or Industrial Applications Wide power range: 15 to 240 W 15 W and PFC Models with Universal voltage of 100 to 230

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

US BROCHURE. Circuit protection according to UL 489 and UL 1077

US BROCHURE. Circuit protection according to UL 489 and UL 1077 US BROCHURE Circuit protection according to UL 489 and UL 1077 2 CIRCUIT PROTECTION UL 489 AND UL 1077 CIRCUIT PROTECTION UL 489 AND UL 1077 3 Table of contents 004 006 Introduction 007 008 Product selction

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

Complete UL/CSA Disconnect Switch Kits

Complete UL/CSA Disconnect Switch Kits Product Selection Complete UL/CSA Disconnect Switch Kits Includes disconnect switch, operating handle with defeater mechanism and operating shaft, NFPA handle, auxiliary contacts, and padlock attachment.

More information

Circuit Protection Methods

Circuit Protection Methods Circuit Protection Methods Differentiating between Supplementary Protection, Branch Circuit Protection, and Self-Protected Devices Introduction Modern electrical equipment continues to increase in complexity

More information

PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:

More information

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Ihr autorisierter Distributor: Neumüller Elektronik GmbH IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet

More information

QUINT-PS/ 1AC/24DC/20/CO

QUINT-PS/ 1AC/24DC/20/CO Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective

More information

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/

Surgelogic. Surge Protective Devices (SPDs) Residential. Catalog 6671CT9701R08/ Surgelogic Surge Protective Devices (SPDs) Residential Catalog 6671CT9701R08/12 2012 CONTENTS Whole House Surge Protective Devices (SPDs).................... 3 SDSB1175C / SDSB1175CB Whole House SPDs..................4

More information

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers

PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers PowerPact M-, P- and R-Frame, and Compact NS630b NS3200 Circuit Breakers Catalog 0612CT0101 R01/17 2017 Class 0216 CONTENTS Description............................................. Page General Information...7

More information