Supplemental Protectors

Size: px
Start display at page:

Download "Supplemental Protectors"

Transcription

1 compact S200 Series Miniature circuit breakers S200, S200P, S200U, S200UP Description The S2 Series of miniature circuit breakers offer a compact solution to protection requirements. The S2 devices are current limiting, DIN rail mounted and can offer a good equivalent to fused systems. The S2 is available with application-specific trip characteristics to provide maximum circuit protection. The breakers offer thermal-magnetic trip protection according to B, C, D, K and Z characteristics. For the worldwide market, the breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. Features Current limiting Fast breaking time ( msec) Unique bus connection system Wide range of accessories Available with variable depth handle mechanism Optional Z curve for SCR protection CE certified and marked DIN rail or front panel mounting Finger safe terminals Multi-function terminals Suitable for reverse feed 480Y/277VAC and 500VDC versions UL489 Listed - branch circuit protective device. UL file # E22323 UL077 Recognized - supplemental protective device. UL file # E7626 UL Approved Miniature Molded Case Circuit Breakers and Supplemental Protectors Low Voltage Products & Systems.

2 S200 Series General information General information Miniature circuit breakers (MCBs) are used throughout the world in all types of electrical installations. ABB MCBs are approved for use by Underwriters Laboratories in systems rated up to 600VAC/VDC. Devices are also certified per CSA. MCBs are approved per IEC-898 and VDE 064, and certified under IEC-947 and VDE 0660 standards for use in systems rated up to 690VAC. MCBs can be applied to 6 2/3Hz 400Hz and DC power systems. Special direct current version MCBs include a permanent magnet for DC fault current interruption. These "UC" versions are rated 250/500VDC under UL077/CSA 22.2 No Continuous current ratings are as low as 0.2 amperes and up to 25 amperes maximum. MCBs are of compact size and can be quickly mounted on standard 35mm DIN rail or can be front mounted by use of a front mounting kit. MCBs include line and load side terminals for conductors from 8 through 4AWG ( mm 2 ) for 63 amperes. MCBs can also be connected via busbar conductors which can be either upper or lower mounted for top feed or bottom feed. Dual function terminals allow busbars to be connected with main incoming line conductors without separate lugs. Accessories Auxiliary devices can be added to the, S200 series MCBs: Shunt trips Auxiliary contacts Bell alarm contacts Aux/bell alarm contacts Undervoltage release Accessory device modules can be field mounted to all above listed ABB MCBs. Auxiliary contacts are also available for the S500 series MCB. Applications MCBs can be used for equipment protection, in commercial appliances, protection of control circuits against overcurrent faults, computer equipment and other computer peripheral devices. UL 489 S200U and S200UP MCBs are listed as molded case circuit breakers for use as branch circuit protective devices. Miniature MCCBs and accessories are listed under UL file E UL 077 S200 and S200P MCBs are recognized as supplementary protectors and are intended for use as overcurrent protection within an appliance or other electrical equipment where branch circuit overcurrent protection is already provided or not required. MCBs and accessories are recognized under UL File E7626. CSA C22.2 MCBs and accessories are certified under CSA C22.2 No. 235 per File LR Tripping characteristics Time-current curves ABB miniature circuit breakers are available with different trip characteristics, allowing for maximum system protection. B Characteristic Available with the S200 and S500 series has rated currents of 6 through 63 amperes in 0 steps. The "B" time-current curve is designed primarily for use in cable protection applications. Instantaneous tripping occurs between approximately 3 to 5 times rated current in 50/60Hz systems. This quick trip curve maximizes protection of control circuits under low short circuit fault levels that could damage control wiring. C Characteristic Available in the S200 and S500 series with rated currents up through 63 amperes and the S290 series with rated currents of 80, 00 and 25 amperes. The "C" time-current curve is designed for medium magnetic start-up currents. Instantaneous tripping occurs between 5 and 0 times rated current in 50/60 Hz systems. D Characteristic The new magnetic trip action has an instantaneous trip between 0 and 20 times the breaker rating. Thus, the S200 and S500-D can be a good protective solution for applications involving high in-rush transformers, motors and other high inductive systems. It is also suitable for any application where a high instantaneous trip point is desired. K Characteristic The "K" time-current characteristic considers high magnetic start-up currents from motors, transformers and other equipment. Instantaneous tripping occurs between 8 and 2 times rated current in 50/60Hz systems. The "K" characteristic is available up through 63 amperes. The "K" curve offers the best protection for the broadest range of electrical systems. The higher magnetic trip settings maximizes protection while allowing for higher in-rush currents during system startup. Available in S200P, S200U, S200UP and S500. Z Characteristic Also available up through 63 amperes, the "Z" characteristic offers instantaneous tripping between 2 and 3 times rated current in 50/60Hz systems. This trip characteristic is available in the S200P, S200U and S200UP series with both the 480Y/277VAC and 250/500VDC ratings. Many applications require a very low short circuit trip setting in order to protect semiconductor or other sensitive devices and the "Z" trip characteristic may provide maximum protection and service in these applications..2 Low Voltage Products & Systems

3 General information Interruption ratings Trip characteristics overview S200 Series Interruption ratings Voltage Rated interrupting Rated MCB capacity current type Comment 20 VAC 0kA A S200-B,C,D A S200-K A S200P-K, Z A S200U-K, Z A S200UP-K, Z 8kA 32-63A S500-B,C,D 26-45A S500-K 30kA 6-25A S500-B,C,D A S500-K 240 VAC 6kA A S200-B,C,D Single pole A S200-K Single pole 0kA A S200-B,C,D Multi pole A S200-K Multi pole A S200P-K,Z Single pole A S200P-K,Z Multi pole A S200U-K,Z Single pole A S200U-K,Z Multi pole A S200UP-K,Z Single pole A S200UP-K,Z Multi pole 8kA 32-63A S500-B,C,D 26-45A S500-K 30kA 6-25A S500-B,C,D A S500-K 277 VAC 6kA A S200-B,C,D A S200-K 0KA A S200P-K,Z A S200UP-K,Z 480Y/277 VAC 6kA A S200-B,C,D A S200-K 0KA A S200P-K,Z A S200UP-K,Z 60 VDC 0kA A S200-B,C,D Single pole A S200-K Single pole 25 VDC 0kA A S200-B,C,D Multi pole A S200-K Multi pole A S280UC-K,Z Single pole 250 VDC 4.5kA A S280UC-K,Z Single pole 500 VDC 4.5kA A S280UC-K,Z Multi pole Trip characteristics overview Curve Magnetic Thermal characteristic characteristic Series B 3-5X.3.45X S200, S500 C 5-0X.3.45X S200, S290, S500 D 0-20X.3.45X S200, S500 K 8-2X.05.20X S200, S500 Z 2-3X.05.20X S200 All values are relative to MCB's ampere rating. Low Voltage Products & Systems.3

4 S200 Series General information Tripping curves 0, B 0, C 0, D seconds AC DC seconds AC DC seconds AC DC multiple of rated current multiple of rated current multiple of rated current 0, K 0, UC-K seconds AC DC seconds DC multiple of rated current multiple of rated current 0, Z 0, UC-Z seconds AC DC seconds DC multiple of rated current multiple of rated current.4 Low Voltage Products & Systems

5 General information Construction details S200 Series Electro-magnetic protection Tripping lever Upper terminal Operating mechanism Thermal protection-bimetal Operator Arc chamber Space for identification marker Fixed contact Moving contact DIN rail holder Lower terminal Low Voltage Products & Systems.5

6 B S200 Series UL 077 CSA C22.2 No. 235 VDE 064 IEC-898 Cable protection S Y/277 VAC Supplemental protectors S20-B, pole S202-B, 2 pole S20-BNA, P+N S203-B, 3 pole Rated Catalog List Delivery current number price class pole 6 S20-B6 $ 36 0 S20-B S20-B S20-B S20-B S20-B S20-B S20-B S20-B S20-B63 56 pole + neutral A S20-B6NA 62 0 S20-B0NA 62 3 S20-B3NA 62 6 S20-B6NA S20-B20NA S20-B25NA 72 B S20-B32NA S20-B40NA S20-B50NA S20-B63NA 02 2 pole 6 S202-B S202-B S202-B S202-B S202-B S202-B S202-B S202-B S202-B S202-B63 28 Sugg. order qty Wgt. oz. ( pc.) A Rated Catalog List Delivery current number price class 3 pole 6 S203-B6 $ 8 0 S203-B0 8 3 S203-B3 8 6 S203-B S203-B S203-B S203-B S203-B S203-B S203-B pole + neutral A S203-B6NA 2 0 S203-B0NA 2 3 S203-B3NA 2 6 S203-B6NA 2 20 S203-B20NA S203-B25NA 68 B S203-B32NA S203-B40NA S203-B50NA S203-B63NA pole 6 S204-B S204-B S204-B S204-B S204-B S204-B S204-B S204-B S204-B S204-B Sugg. order qty B 8.0 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) S204-B, 4 pole S203-BNA, 3P+N 0, B seconds AC DC multiple of rated current.6 Discount schedule CB5 Low Voltage Products & Systems

7 S Y/277 VAC Supplemental protectors S200 Series C UL 077 CSA C NO. 235 VDE 064 IEC-898 Cable & equipment protection 0, S20-C, pole S202-C, 2 pole S20-CNA, P+N S203-C, 3 pole S204-C, 4 pole S203-CNA, 3P+N C Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty pole 0.5 S20-C0.5 $ 42 S20-C 42.6 S20-C S20-C S20-C S20-C S20-C S20-C S20-C0 42 A S20-C S20-C S20-C S20-C S20-C S20-C S20-C S20-C63 68 pole + neutral 0.5 S20-C0.5NA 84 S20-CNA 84.6 S20-C.6NA 84 2 S20-C2NA 84 3 S20-C3NA 84 4 S20-C4NA 84 6 S20-C6NA 84 8 S20-C8NA 84 0 S20-C0NA 84 3 S20-C3NA 84 6 S20-C6NA S20-C20NA S20-C25NA S20-C32NA S20-C40NA S20-C50NA 2 63 S20-C63NA 30 2 pole 0.5 S202-C S202-C 96.6 S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C S202-C63 52 B A Rated Catalog List Delivery current number price class 3 pole 0.5 S203-C0.5 $ 38 S203-C 38.6 S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C S203-C pole + neutral 0.5 S203-C0.5NA 200 S203-CNA S203-C.6NA S203-C2NA S203-C3NA S203-C4NA S203-C6NA S203-C8NA S203-C0NA S203-C3NA S203-C6NA S203-C20NA S203-C25NA S203-C32NA S203-C40NA S203-C50NA S203-C63NA pole 0.5 S204-C S204-C 28.6 S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C S204-C Sugg. order qty Wgt. oz. ( pc.) A 3.5 B 8.0 B Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds AC DC multiple of rated current Low Voltage Products & Systems Discount schedule CB5.7

8 S200 Series S Y/277 VAC Supplemental protectors D UL 077 CSA C22.2 VDE 064 IEC-898 Cable & equipment protection Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) S20-D, pole S202-D, 2 pole pole 0.5 S20-D0.5 $ 42 S20-D 42.6 S20-D S20-D S20-D S20-D S20-D S20-D S20-D0 42 A S20-D S20-D S20-D S20-D S20-D S20-D S20-D S20-D pole 0.5 S202-D S202-D 96.6 S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D S202-D63 52 A pole 0.5 S203-D0.5 $ 38 S203-D 38.6 S203-D S203-D S203-D S203-D S203-D S203-D8 38 A S203-D S203-D S203-D S203-D S203-D S203-D S203-D S203-D S203-D S203-D, 3 pole 0, D seconds AC DC multiple of rated current.8 Discount schedule CB5 Low Voltage Products & Systems

9 S Y/277 VAC Supplemental protectors S200 Series K UL 077 CSA C NO. 235 VDE 064 IEC-898 Cable & equipment protection seconds 0, S20-K, pole S202-K, 2 pole S20-KNA, P+N S203-K, 3 pole S204-K, 4 pole S203-KNA, 3P+N K AC DC Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty pole 0.5 S20-K0.5 $ 42 S20-K 42.6 S20-K S20-K S20-K S20-K S20-K S20-K S20-K S20-K S20-K3 42 A S20-K S20-K S20-K S20-K S20-K S20-K S20-K S20-K S20-K S20-K63 68 pole + neutral 0.5 S20-K0.5NA 84 S20-KNA 84.6 S20-K.6NA 84 2 S20-K2NA 84 3 S20-K3NA 84 4 S20-K4NA 84 6 S20-K6NA 84 8 S20-K8NA 84 0 S20-K0NA 84 B S20-K3NA 84 6 S20-K6NA S20-K20NA S20-K25NA S20-K32NA S20-K40NA S20-K50NA 2 63 S20-K63NA 30 2 pole 0.5 S202-K S202-K 96.6 S202-K S202-K S202-K S202-K S202-K S202-K S202-K S202-K0 96 A S202-K S202-K S202-K S202-K S202-K S202-K S202-K S202-K S202-K S202-K S202-K63 52 Rated Catalog List Delivery current number price class 3 pole Sugg. order qty Wgt. oz. ( pc.) 0.5 S203-K0.5 $ 38 S203-K 38.6 S203-K S203-K S203-K S203-K S203-K S203-K S203-K S203-K S203-K3 38 A S203-K S203-K S203-K S203-K S203-K S203-K S203-K S203-K S203-K S203-K pole + neutral 0.5 S203-K0.5NA 200 S203-KNA S203-K.6NA S203-K2NA S203-K3NA S203-K4NA S203-K6NA S203-K8NA S203-K0NA 200 B S203-K3NA S203-K6NA S203-K20NA S203-K25NA S203-K32NA S203-K40NA S203-K50NA S203-K63NA pole 0.5 S204-K S204-K 28.6 S204-K S204-K S204-K S204-K S204-K S204-K8 28 B S204-K S204-K S204-K S204-K S204-K S204-K S204-K S204-K S204-K Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time multiple of rated current Low Voltage Products & Systems Discount schedule CB5.9

10 S200 Series S200P 480Y/277 VAC Supplemental protectors K UL 077 CSA C NO. 235 VDE 0660 Cable & equipment protection S20P-K, pole S202P-K, 2 pole S203P-K, 3 pole Rated Catalog List Delivery current number price class pole 0.2 S20P-K0.2 $ S20P-K S20P-K S20P-K S20P-K 54.6 S20P-K S20P-K S20P-K S20P-K S20P-K S20P-K8 54 A S20P-K S20P-K S20P-K S20P-K S20P-K S20P-K S20P-K S20P-K S20P-K pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S202P-K S202P-K S202P-K S202P-K S202P-K 28.6 S202P-K S202P-K S202P-K S202P-K S202P-K6 28 A S202P-K S202P-K S202P-K S202P-K S202P-K S202P-K S202P-K S202P-K S202P-K S202P-K63 82 Rated Catalog List Delivery current number price class 3 pole 0.2 S203P-K0.2 $ S203P-K S203P-K S203P-K S203P-K 94.6 S203P-K S203P-K S203P-K S203P-K S203P-K6 94 A S203P-K S203P-K S203P-K S203P-K S203P-K S203P-K S203P-K S203P-K S203P-K S203P-K Delivery Class Sugg. order qty A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) 0, K seconds AC DC multiple of rated current.0 Discount schedule CB7 Low Voltage Products & Systems

11 S280 (W) 480Y/277 VAC Supplemental protectors S200 Series K UL 077 CSA C NO. 235 VDE 0660 Cable & equipment protection S28-KW, pole S282-KW, 2 pole S283-KW, 3 pole Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) pole 0.2 S28-K0.2W $ S28-K0.3W S28-K0.5W S28-K0.75W 54 S28-KW 54.6 S28-K.6W 54 2 S28-K2W 54 3 S28-K3W 54 4 S28-K4W 54 6 S28-K6W 54 8 S28-K8W 54 B S28-K0W 54 3 S28-K3W 54 6 S28-K6W S28-K20W S28-K25W S28-K32W S28-K40W S28-K50W S28-K63W 80 2 pole 0.2 S282-K0.2W S282-K0.3W S282-K0.5W S282-K0.75W 28 S282-KW 28.6 S282-K.6W 28 2 S282-K2W 28 3 S282-K3W 28 4 S282-K4W 28 6 S282-K6W 28 B S282-K8W 28 0 S282-K0W 28 3 S282-K3W 28 6 S282-K6W S282-K20W S282-K25W S282-K32W S282-K40W S282-K50W S282-K63W 82 Rated Catalog List Delivery current number price class 3 pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S283-K0.2W $ S283-K0.3W S283-K0.5W S283-K0.75W 94 S283-KW 94.6 S283-K.6W 94 2 S283-K2W 94 3 S283-K3W 94 4 S283-K4W 94 6 S283-K6W 94 B S283-K8W 94 0 S283-K0W 94 3 S283-K3W 94 6 S283-K6W S283-K20W S283-K25W S283-K32W S283-K40W 2 50 S283-K50W S283-K63W 280 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds 0, K AC DC For use with ring tongue terminal connectors multiple of rated current Low Voltage Products & Systems Discount schedule CB7.

12 K UL S200 Series 077 VDE 0660 CSA 22.2 No. 235 Cable and Equipment Protection S280UC 500 VDC Supplemental protectors S28UC-K, pole S282UC-K, 2 pole S283UC-K, 3 pole Rated Catalog List Delivery current number price class pole 0.2 S28UC-K0.2 $ S28UC-K S28UC-K S28UC-K S28UC-K 04.6 S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K6 04 B S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K S28UC-K pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K4 242 B S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K S282UC-K Rated Catalog List Delivery current number price class 3 pole 0.2 S283UC-K0.2 $ S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K S283UC-K Sugg. order qty B Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) Direct current applications The S280UC differs from standard miniature circuit breakers in that the UC versions include a permanent magnet which aids in the extinguishing of the arc during medium and high level faults. It is necessary to observe the correct polarity and current direction when connecting the UC breakers. Two examples of correct connection are shown below. seconds UC-K 0, DC multiple of rated current - +2 Maximum voltage between leads 250VDC 500VDC Single Pole S28UC L- L+ LOAD - + Two Pole L- L+ S282UC L- L LOAD - + LOAD - + Termination points are marked on all UC type MCBs, points one () and four (4) are negative and points two (2) and three (3) are positive. Four pole breakers are also available for voltage reversal applications Discount schedule CB7 Low Voltage Products & Systems

13 S200P & S280UC 480Y/277 VAC & 500 VDC Supplemental protectors S200 Series Z UL 0, VDE 0660 CSA 22.2 No. 235 Fast trip characteristic S20P-Z, pole S202P-Z, 2 pole S203P-Z, 3 pole Z 480Y/277 VAC 500 VDC Rated Catalog List Delivery current number price class pole Sugg. order qty Wgt. oz. ( pc.) 0.5 S20P-Z0.5 $ 70 S20P-Z 70.6 S20P-Z S20P-Z S20P-Z S20P-Z S20P-Z S20P-Z8 70 B S20P-Z S20P-Z S20P-Z S20P-Z S20P-Z S20P-Z S20P-Z S20P-Z pole 0.5 S202P-Z S202P-Z 62.6 S202P-Z S202P-Z S202P-Z S202P-Z S202P-Z S202P-Z8 62 B S202P-Z S202P-Z S202P-Z S202P-Z S202P-Z S202P-Z S202P-Z S202P-Z pole 0.5 S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z8 244 B S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z S203P-Z , UC-Z Rated Catalog List Delivery current number price class pole 0.5 S28UC-Z0.5 $ 68 S28UC-Z 68.6 S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z0 68 B S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z S28UC-Z pole 0.5 S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z S282UC-Z pole Delivery Class Sugg. order qty B S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z8 594 B S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z S283UC-Z A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Wgt. oz. ( pc.) seconds 0.5 AC DC multiple of rated current seconds DC multiple of rated current Low Voltage Products & Systems Discount schedule CB7.3

14 S200 Series S200U 240 VAC Miniature MCCBs K UL 489 CSA C NO. 5 VDE 0660 Cable & equipment protection S20U-K, pole S202U-K, 2 pole S203U-K, 3 pole S204U-K, 4 pole K Rated Catalog List Delivery current number price class pole 0.2 S20U-K0.2 $ S20U-K S20U-K S20U-K S20U-K 54.6 S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K0 54 A S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K S20U-K pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S202U-K S202U-K S202U-K S202U-K S202U-K 28.6 S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K8 28 A S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K S202U-K63 82 Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 3 pole 0.2 S203U-K0.2 $ S203U-K S203U-K S203U-K S203U-K 94.6 S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K0 94 A S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K S203U-K pole 0.2 S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K0 265 B S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K S204U-K seconds 0, AC DC UL489 listed as branch circuit protective device Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time multiple of rated current. Discount schedule CB2 Low Voltage Products & Systems

15 S200U 240 VAC Miniature MCCBs S200 Series Z UL 489 CSA C NO. 5 VDE 0660 Cable & equipment protection S20U-Z, pole S202U-Z, 2 pole S203U-Z, 3 pole Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty pole 0.5 S20U-Z S20U-Z S20U-Z 70.6 S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z0 70 A S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z S20U-Z pole 0.5 S202U-Z S202U-Z S202U-Z 62.6 S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z0 62 A S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z S202U-Z Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 3 pole 0.5 S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z0 244 A S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z S203U-Z pole 0.5 S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z0 343 B S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z S204U-Z Delivery Class 0, S204U-Z, 4 pole Z UL489 listed as branch circuit protective device A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds AC DC multiple of rated current Low Voltage Products & Systems Discount schedule CB2.5

16 S200 Series S200UP 480Y/277 VAC Miniature MCCBs K UL 489 CSA C NO. 5 VDE 0660 Cable & equipment protection S20UP-K, pole S202UP-K, 2 pole S203UP-K, 3 pole Rated Catalog List Delivery current number price class pole 0.2 S20UP-K0.2 $ S20UP-K S20UP-K S20UP-K S20UP-K 90.6 S20UP-K S20UP-K S20UP-K S20UP-K S20UP-K S20UP-K S20UP-K8 90 A S20UP-K S20UP-K S20UP-K S20UP-K S20UP-K S20UP-K pole Sugg. order qty Wgt. oz. ( pc.) 0.2 S202UP-K S202UP-K S202UP-K S202UP-K S202UP-K 20.6 S202UP-K S202UP-K S202UP-K S202UP-K S202UP-K S202UP-K6 20 A S202UP-K S202UP-K S202UP-K S202UP-K S202UP-K S202UP-K S202UP-K25 20 Rated Catalog List Delivery Sugg. Wgt. oz. current number price class order ( pc.) qty 3 pole 0.2 S203UP-K0.2 $ S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K6 320 A S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K S203UP-K pole 0.2 S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K6 440 B S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K S204UP-K Delivery Class 0, S204UP-K, 4 pole K UL489 listed as branch circuit protective device A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds AC DC multiple of rated current.6 Discount schedule CB7 Low Voltage Products & Systems

17 S200UP 480Y/277 VAC Miniature MCCBs S200 Series Z UL 489 CSA C NO. 5 VDE 0660 Cable & equipment protection S20UP-Z, pole S202UP-Z, 2 pole Rated Catalog List Delivery current number price class pole 0.5 S20UP-Z S20UP-Z S20UP-Z 5.6 S20UP-Z S20UP-Z2 5 3 S20UP-Z3 5 4 S20UP-Z4 5 5 S20UP-Z5 5 6 S20UP-Z6 5 8 S20UP-Z8 5 A S20UP-Z0 5 5 S20UP-Z5 5 6 S20UP-Z S20UP-Z S20UP-Z pole Sugg. order qty Wgt. oz. ( pc.) 0.5 S202UP-Z S202UP-Z S202UP-Z S202UP-Z S202UP-Z S202UP-Z S202UP-Z S202UP-Z S202UP-Z6 270 A S202UP-Z S202UP-Z S202UP-Z S202UP-Z S202UP-Z S202UP-Z Rated Catalog List Delivery current number price class Sugg. order qty Wgt. oz. ( pc.) 3 pole 0.5 S203UP-Z S203UP-Z S203UP-Z S203UP-Z S203UP-Z S203UP-Z S203UP-Z S203UP-Z S203UP-Z6 400 A S203UP-Z S203UP-Z S203UP-Z S203UP-Z S203UP-Z S203UP-Z pole 0.5 S204UP-Z S204UP-Z S204UP-Z S204UP-Z S204UP-Z S204UP-Z S204UP-Z S204UP-Z S204UP-Z6 564 B S204UP-Z S204UP-Z S204UP-Z S204UP-Z S204UP-Z S204UP-Z S203UP-Z, 3 pole Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 0, S204UP-Z, 4 pole Z UL489 listed as branch circuit protective device seconds AC DC multiple of rated current Low Voltage Products & Systems Discount schedule CB7.7

18 S200 Series S Y/277 VAC C VDE 0660 Cable and equipment protection S29-C VAC Rated Catalog List Delivery current number price class pole Sugg. order qty Wgt. oz. ( pc.) 80 S29-C80 $ S29-C00 4 B S29-C pole 80 S292-C S292-C B S292-C pole 80 S293-C S293-C B S293-C pole 80 S294-C S294-C B S294-C S290-H Auxiliary contact S290-H 72 B.75 Bell alarm S290-S 2 B.75 Shunt trip S290-A 4 B 6.2 For field mounting, left side, 0V 45VAC S290-A2 4 B 6.2 For field mounting, left side, 24 48VDC Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time 0, C seconds AC DC multiple of rated current.8 Discount schedule CB2 Low Voltage Products & Systems

19 Accessories Busbars S200 Series For use on: Amp Number Busbar End cap Catalog List Delivery Suggested rating of length catalog number price class order qty. poles (mm) number quantity S200 & PS-END0 PS/60 $ 36 A S200P PS-END0 PS/60/6 46 Weight (ozs) 9 S200U & 6 08 PS/6/6BP 30.4 S200UP PS/2/6BP 60 B PS/8/6BP For use on: Amp Number Busbar End cap Catalog List Delivery Suggested rating of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & PS-ENDSP PS2/58SP $ 22 S200P PS-ENDSP PS2/58/6SP 52 A 8 S200U & 6 08 PS2/6/6BP 40.8 S200UP PS2/2/6BP 80 B PS2/8/6BP For use on: Amp Number Busbar End cap Catalog List Delivery Suggested rating of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & PS-ENDSP PS3/60SP $ 30 2 A S200P PS-ENDSP PS3/60/6SP S200U & 6 08 PS3/6/6BP 44 2 S200UP PS3/2/6BP 88 B PS3/8/6BP 32 6 For use on: S200 & S200P Amp Number Busbar End cap Catalog List Delivery Suggested Weight rating of length catalog number price class order qty. (ozs) poles (mm) number quantity PS-ENDSP PS4/60/6SP $ 236 B 22 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time NOTE All bus bars may be center fed in order to double the ampacity rating NOTE BUS BARS MAY BE USED ON LINE OR LOAD SIDE OF MCBS UL Approved for use on UL077 miniature circuit breakers. UL File #E UL approved for use on UL 489 miniature circuit breakers. UL File # E UL 489 bus bars may not be cut. Low Voltage Products & Systems Discount schedule CB8.9

20 S200 Series Accessories Busbars Phase with auxiliary Amp Number Busbar End cap Catalog List Delivery Suggested For Weight rating of length catalog number price class order qty. use on: (ozs) poles (mm) number quantity S200 & PS-END0 PS/38H $ 50 B 7.4 S200P PS-END0 PS/38/6H L L L L... 2 Phase with auxillary For use on: Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & S200P PS-ENDSP PS2/48/6SP $ 74 B 23.3 L L2 L L2 L L2 L L Phase with auxillary For use on: Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity Weight (ozs) S200 & S200P PS-ENDSP PS3/39/6SP $ 58 B 22.6 L L2 L3 L L2 L3 L L2 L3... For use on: S200 & S200P Amp rating Number Busbar End cap Catalog List Delivery Suggested Weight of length catalog number price class order qty. (ozs) poles (mm) number quantity PS-ENDSP PS4/58/6NSP $ 238 B 30.8 Insulated busbar assembly contains 4 separate circuits for use with +N or 2 pole MCBs. Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time NOTE All bus bars may be center fed in order to double the ampacity rating NOTE BUS BARS MAY BE USED ON LINE OR LOAD SIDE OF MCBS.20 Discount schedule CB8 Low Voltage Products & Systems

21 Accessories S200 Series Auxiliary contacts For field mounting: right side Form C NO / NC Electrical For Catalog List Delivery Suggested Wgt. oz. accessories use on: number price class order quantities ( pc.) S200 & S200P S200U S200UP S2C-H6R S2C-H6RU $ 36 A.4 S2C-H6R The auxiliary contacts will signal whether the breaker is in the ON or OFF position. The contacts are rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. Wire size: 8 AWG to 6 AWG. S2C-S/H6R Bell alarm S200 & S200P S2C-S/H6R For field mounting, right side 48 A.4 S200U S200UP S2C-S6RU The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. The contact is rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. * Combination bell alarm/auxiliary contact S2C-A_ Shunt trip S200 & S2C-A For field mounting, right side S200P S2C-A2 A: 2-60 VAC (2-60VDC) 38 A 5.2 A2: 0-45 VAC (0-250 VDC) S200U & S2C-AU S200UP S2C-A2U For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Shunt trips are available for on control system voltage (2-45 VAC/VDC). Undervoltage release For field mounting, right side 2 VDC S2C-UA2 24 VAC S2C-UA24 48 VAC S200 & S2C-UA48 0 VAC S200P S2C-UA0 220 VAC S2C-UA VAC S2C-UA A 5.2 When control voltage drops below approximately 50% of rated voltage, the UVR opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Similar in size and mounting to the shunt trip accessory. S2C-UA_ Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Low Voltage Products & Systems Discount schedule CB8 9/6/07 Rev..2

22 S200 Series Accessories S200 S500-ME2 MB-CL MB-3PD SA Electrical Catalog List Delivery Suggested Wgt. oz. accessories number price class order quantities ( pc.) Front mounting kit For 2 poles S500-ME $ For 2 5 poles S500-ME2 70 A 2.9 For 2 0 poles S500-ME Optional rear terminals S500-K 6.5 Includes flange, mounting rail and hardware. Front mounting clip For 4 poles MB-CL 35 A 2 Simple mounting clip for up to four module mounting. Front mounting bracket For 3 poles MB-3PD 35 A 2.5 For flush mounting of three pole MCBs: includes hardware. Locking device Adaptor only SA 9 A Padlock only w/ 2 keys SA Allows breaker to be locked in ON or OFF position. Labeling accessory sheet = 40 blank labels BS 74 sheet = 40 numbered labels BS/40 74 Adhesive labels mount on front face of components. Enclosure, IP40 A For 2 modules For 4 modules B 2.8 For 6 modules For 8 modules For additional protection against accidental contact. Includes integrated mounting rail. SA2 Enclosure, IP55 For 4 modules For 6 modules A 0.8 For 0 modules For 20 modules Molded plastic complete with mounting rail and knock-outs for cable entries Blanking plates Single pole (set of 0) BP-P 6 A Twelve pole (snap-off, set of ) BP-2P 7 Handle mechanism For use with 2, 3 and 4 pole S2 MCBs and disconnect switch handles with 5mm shaft. S2C-DH 76 A 9.2 DIN rail Universal mounting SMR-39 2 A 8 35mm DIN rails are available in 39-inch strips ( meter). S2C-DH Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time SMR Discount schedule CB8 Low Voltage Products & Systems Discount schedule H6 Handles & shafts

23 Accessories S200 S200 Series SZ-BSK SZ-ESK2 SZ-AST55_ Busbar accessories Busbar end caps Catalog List Delivery Suggested Weight Description number price class order qty. ounce qty. (2 pc.) Busbar tooth covers (shrouds unused portion of busbar) 2 & 3 phase PS-ENDSP 4 phase PS-ENDSP $ 2 A 0 SZ-BSK 4 A 0 Busbar mounted terminal block, pole, for use on all busbars. SZ-ESK2 0 A.0 Wire size: AWG to 2 AWG Electrical accessories Posidrive tools Item Catalog List Delivery Suggested Wgt. oz. number price class order quantities ( pc.) Screwdriver, # SD-PZ $ 40 A 4 Screwdriver, #2 SD-PZ2 40 A 4 Bit, # BIT-PZ 4 A 4 Bit, #2 BIT-PZ2 4 A 4 Connection terminals Cross section For Catalog List Delivery Suggested Wgt. oz. AWG/mm 2 use on: number price class order quantities ( pc.) /0 (50mm 2 ) Straight SZ-AST55I $ S200 & S200P B /0 (50mm 2 ) 90 SZ-AST50I /0 (50mm 2 ) Straight SZ-AST55U S200U & S200UP B /0 (50mm 2 ) 90 SZ-AST50U Ring tongue accessories Catalog List Delivery Suggested Weight Description For use on number price class order qty. ounce qty. (2 pc.) Ring tongue terminal S200 & S200P S200U & S200UP SZ-AST55UPRT $ 5 A Plug S2C-P N/C A 0 SZ-AST50_ Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Low Voltage Products & Systems Discount schedule CB8.23 9/6/07 Rev.

24 S200 Series Technical data Mounting and operating instructions Mounting MCB Removing MCB Mounting Universal mounting position using snap-on mounting to standard 35x7.5mm DIN rail. Miniature circuit breakers (MCBs) can also be mount ed to front of door using a panel cut-out with breaker handle pro trud ing through panel opening for external operation. Special front mount ing kit page 23. Connection Terminals are suitable for solid or flexible conductors from 8 to 4 AWG (0.75 to 25mm 2 ) with no busbar connected. When max i mum busbar size of 36 mm 2 is used, maximum cable is 6 AWG (6 mm 2 ). Maximum tightening torque of 7.5 in-lb (2 Nm) for line/load terminals and 4.5 in-lb (0.5Nm) for ac ces so ry device terminals. Operation MCBs are switched on by moving the handle to the upper po si tion. Stamped onto the handle switch, a I is visible confirming that the breaker is closed. The MCBs are trip-free, if the handle is being forced to the ON position, the breaker will still trip under fault conditions. The O marking indicates that the breaker is in the OFF position. The MCB is now open and the load is disconnected from line power. When a breaker has tripped, the MCB handle should first be set to the full OFF position to make certain the trip mechanism has been reset. Once the fault has been determined and cleared the MCB can again be switched ON. Maintenance ABB miniature circuit breakers require no special maintenance; only normal electrical system maintenance pro ce dures are required. Possible mounting arrangements of MCB accessories Legend S 200 +S/H+S/H (H)+S/H (H) Auxiliary contact Bell alarm/auxiliary contact H S/H +H+H+H Bell alarm/auxiliary contact used as auxiliary contact S/H (H) Shunt trip ST Undervoltage release UR +ST+H+H+H +ST+S/H+S/H (H)+S/H (H) +UR+H+H+H +UR+S/H+S/H (H)+S/H (H).24 Low Voltage Products & Systems

25 Technical data Busbars & connectors Connection methods S200 Series Top and bottom dual function terminals provided in open position for connection to busbars or cable. Terminals allow for connection of cable 8-4 AWG [top row] and 8-8 AWG [bottom row]. Two slots per terminal offer the ability to connect, independently, two conductors. This may be cables or bus bar. Top and bottom terminals may be bussed together with single phase or multi-phase busbars as shown. Both line and load side terminals can be bus bar connected. Easy removal of devices from an assembly when using bus bar in the bottom, load side terminals. Conductors may only be inserted into open terminals, preventing mis-wiring and potential problems. Low Voltage Products & Systems.25

26 S200 Series Technical data Item S200-B S200-C, -D S200-K S200P-K Approvals: UL CSA C22.2 No.235 C22.2 No. 235 C22.2 No. 235 VDE 064, IEC 898, , , , 947 No. of poles:,2,3,4 +N,3+N,2,3, +N,3+N,2,3,4, +N,3+N,2,3,4,+N,3+N Tripping characteristic: B C,D K K Rated currents: 6 to 63A 0.5 to 63A 0.5 to 63A 0.2 to 63A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 20VAC 0kA 0kA 0kA 0kA 240VAC 6kA 0kA 6kA 0kA 6kA 0kA 0kA 0kA 277VAC 6kA 6kA 6kA 0kA 277/480 VAC 6kA 6kA 6kA 0kA 60VDC 0kA 0kA 0kA 0kA 0kA 0kA 25VDC 0kA 0kA 0kA Frequency: 50/60Hz (See below) 50/60Hz (see below) 50/60Hz (see below) 50/60Hz (see below) Rated voltage IEC single pole 240/45VAC 240/45VAC 240/45VAC 240/45VAC 60VDC 60VDC 60VDC 60VDC IEC multi-pole 45VAC 45VAC 45VAC 45VAC 0VDC 0VDC 0VDC 0VDC Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm Mounting position: optional optional optional optional Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN rail 35mm DIN rail Main and shunt trip terminals: Wire size 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-8 [bottom] 8-8 [bottom] 8-8 [bottom] 8-8 [bottom] Torque 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -25 C to +70 C -25 C to +70 C -25 C to +70 C -25 C to +70 C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, ~ I 0.8 ~ I 0.8 ~ I 0.8 ~ I n Disconnecting neutral rating: 6kA switching 6kA switching 6kA switching Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 50/60Hz ap pli ca tions. For frequencies other than 50/60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz DC Approx. factor Thermal tripping is independent of frequency..26 Low Voltage Products & Systems

27 Technical data S200 Series Item S280UC-K S200P-Z S280UC-Z S290-C Approvals: UL CSA VDE IEC 898, , , No. of poles:,2,3,2,3,4,2,3,2,3,4 Tripping characteristic: K Z Z C Rated currents: 0.2 to 63A 0.5 to 63A 0.5 to 63A 80 to 25A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & Single pole Multi pole Single pole Multi pole Single pole Multi pole interrupting capacity 20VAC 0kA 0kA 0kA 240VAC 0kA 0kA 0kA 0kA 0kA 0kA 277VAC 0kA 0kA 0kA 277/480 VAC 4.5kA for A 0kA 4.5kA for A 5kA for 50-63A 5kA for 50-63A 60VDC 0kA 0kA 0kA 0kA 25VDC 0kA 0kA 0kA 0kA 250VDC 4.5kA 4.5kA 4.5kA 4.5kA 500VDC 4.5kA 4.5kA Frequency: 50/60Hz (see below) 50/60 Hz (see below) 50/60Hz (see below) 50/60Hz (see below) Rated voltage IEC single pole 240/45VAC 240/45VAC 240/45VAC 230/440VAC 220VDC 60VDC 220VDC 60VDC IEC multi-pole 45VAC 45VAC 45VAC 440VAC 440VDC 0VDC 440VDC 0VDC Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 70mm Mounting position: optional optional optional optional Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN-rail 35mm DIN-rail Main and shunt trip terminals: Wire size A 8-4 AWG 8-4 AWG [top] A 8-4 AWG 80-25A -/0 AWG 50A & above 8-2 AWG 8-8 AWG [bottom] 8-2 AWG Torque 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -25 C to +55 C -25 C to +70 C -25 C to +55 C -5 C to +45 C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 60m/s 2, at ~ I 0.8 ~ I 0.8 ~ I n Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 50/60Hz ap pli ca tions. For frequencies other than 50/60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz DC Approx. factor Thermal tripping is independent of frequency. Low Voltage Products & Systems.27

28 S200 Series Technical data Item S200U-K S200U-Z S200UP-K S200UP-Z Approvals: UL CSA C22.2 No.5 C22.2 No.5 C22.2 No.5 C22.2 No.5 VDE IEC 898, , , No. of poles:,2,3,4,2,3,4,2,3,4,2,3,4 Tripping characteristic: K Z K Z Rated currents: 0.2 to 63A 0.2 to 63A 0.2 to 25A 0.2 to 25A Minimum operating voltage: 2V 2V 2V 2V UL/CSA rated voltage & interrupting capacity 20VAC 0kA 0kA 0kA 0kA 240VAC 0kA 0kA 0kA 0kA 277VAC 0kA 0kA 480/277 VAC 0kA 0kA Frequency: 50/60Hz (see below) 50/60 Hz (see below) 50/60Hz (see below) 50/60Hz (see below) Rated voltage IEC single pole 240/45VAC 240/45VAC 240/45VAC 240/45VAC 220VDC 60VDC 220VDC 220VDC IEC multi-pole 45VAC 45VAC 45VAC 45VAC 440VDC 0VDC 440VDC 440VDC Protection category: IP20 IP20 IP20 IP20 Depth of unit per DIN 43880: 68mm 68mm 68mm 68mm Mounting position: optional optional optional optional Standard mounting: 35mm DIN rail 35mm DIN rail 35mm DIN-rail 35mm DIN-rail Main and shunt trip terminals: Wire size 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-4 AWG [top] 8-8 AWG [bottom] 8-8 AWG [bottom] 8-8 AWG [bottom] 8-8 AWG [bottom] Torque 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. 7.5 in-lbs. Tool #2 Posidrive #2 Posidrive #2 Posidrive #2 Posidrive Accessory terminals Wire size 8-6 AWG 8-6 AWG 8-6 AWG 8-6 AWG Torque 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. 4.5 in-lbs. Tool # Posidrive # Posidrive # Posidrive # Posidrive Service life at rated load: I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n < 32 A, 20,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations I n > 32 A, 0,000 operations Ambient temperatures: -25 C to +70 C -25 C to +70 C -25 C to +70 C -25 C to +70 C Storage temperatures -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C -40 C to + 70 C Shock resistance: 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, 30g minimum of 2 impacts, shock duration of 3ms shock duration of 3ms shock duration of 3ms shock duration of 3ms Vibration resistance: 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, 50 Hz 5g, 20 cycles, 5 Hz, ~ I 0.8 ~ I 0.8 ~ I 0.8 ~ I n Influence of frequency on electro-magnetic trips Magnetic trip values shown on trip curves are valid for 50/60Hz ap pli ca tions. For frequencies other than 50/60Hz, the mag net ic (in stan ta neous) trip values are increased by the factor given below: 6 2/3-60Hz 00Hz 200Hz 400Hz DC Approx. factor Thermal tripping is independent of frequency..28 Low Voltage Products & Systems

29 Technical data Wire size comparison S200 Series Comparison of IEC and AWG wire sizes mm AWG (mm ) Amps / UL Amps / IEC (.3) (2.) (3.3) (5.3) (8.4) (3.3) (2.2) (26.7) 00 2 (33.6) Ampacities for AWG wire are based on copper cable rated 75 C, except for 6AWG which is based on 60 C wire. Taken from UL508 Table Consult applicable standards for futher detail and information. Low Voltage Products & Systems.29

30 S200 Series Approximate dimensions S200, S200P, S200U, S200UP Inches [Millimeters] S200 & S200P S200U S200UP S290 Accessories mount to right side of MCB only A, -A2 Shunt trip -H Auxiliary switch -S Bell alarm.30 Low Voltage Products & Systems

31 Inches [Millimeters] Approximate dimensions Accessories S200 Series Accessories mm S 2C-A... S 2C-UA... S 2C-H... S 2C-S... S 2C-S/H MB-CL Front mounting clip mm D C.L C.L. MB-3PD Front mounting bracket in 2.2 ( 3P ).43 ( 2P ).87 C L C L BREAKER CUT OUT 0.74 ( P ) S2C-DH Handle mechanism CL BKT. MT. HOLES 0.25 DIA. TYP 2 CL Low Voltage Products & Systems.3

32 S200 Series Approximate dimensions Accessories Inches [Millimeters] Low Voltage Products & Systems

33 Cross-reference S200 Series Older Suggested Physical Electrical version replacement comparison comparison series S260-B S200-B Same pole spacing Same trip char ac ter is tic S260-C S200-C Same pole spacing Same trip char ac ter is tic S260-D S200-D Same pole spacing Same trip char ac ter is tic S270-K S200-K Same pole spacing Same trip char ac ter is tic S280-K S200P-K Same pole spacing Same trip char ac ter is tic S280-Z S200P-Z Same pole spacing Same trip char ac ter is tic S280U-K S200U-K Same pole spacing Same trip char ac ter is tic S280UX-K S200U-K Smaller pole spacing Same trip char ac ter is tic Many older styles of ABB miniature circuit breakers have been replaced by new and improved versions. Many of these newer styles can be directly interchanged, both electrically and physically, with the older version. There are also many international styles of ABB circuit breakers which are not normal stock items and may be interchanged with stocked ABB versions. Low Voltage Products & Systems.33

34 S200 Series Notes.34 Low Voltage Products & Systems

35 Miniature Circuit Breakers compact S500 Series S500 Series Description Increasing energy requirements result in larger short-circuit currents which place heavy demands on protective switchgear regarding safety, reliability and switching capacities. The S500 heavy-duty circuit breaker fulfills these requirements by virtue of its technical features. It is equipped with a thermal and/or electromagnetic release to protect circuits, motors, switchgear and systems from the effects of overload and short-circuit currents. For the worldwide market, the S500 breakers carry UL, CSA, IEC, CE and many other agency approvals. Features High breaking capacity Energy-limiting Current-limiting Extremely fast breaking time Optimal selectivity Various versions for special applications Compact dimensions, DIN cap size Easy and quick to install Easy to connect; finger safe terminals Wide range of accessories UL 077 recognized 600VAC and 500VDC versions UL File # E67556 Low Voltage Products & Systems.35

36 S500 Series S Y/277 VAC B UL 077 CSA C22.2 VDE 064 IEC C VDE UL 077 CSA C IEC , S50-C6 S502-C6 S503-C0 B Rated Catalog List Delivery Weight current number price class (oz.) pc pole 6 S50-B6 $ 68 0 S50-B S50-B S50-B S50-B S50-B25 68 B S50-B S50-B S50-B S50-B pole 3 pole 6 S502-B S502-B S502-B S502-B S502-B S502-B S502-B S502-B S502-B S502-B S503-B S503-B S503-B S503-B S503-B S503-B S503-B S503-B S503-B S503-B B 7.85 B Rated Catalog List Delivery Weight current number price class (oz.) pc pole 6 S50-C6 $ 68 0 S50-C S50-C S50-C S50-C S50-C25 68 B S50-C S50-C S50-C S50-C pole 6 S502-C S502-C S502-C S502-C S502-C S502-C S502-C S502-C S502-C S502-C pole 6 S503-C S503-C S503-C S503-C S503-C S503-C S503-C S503-C S503-C S503-C B 7.85 B seconds seconds AC DC multiple of rated current C 0, AC DC multiple of rated current D VDE Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) pole 3 S50-D3 $ 90 6 S50-D S50-D S50-D S50-D32 90 B S50-D S50-D S50-D pole 3 pole UL 077 CSA C IEC S502-D S502-D S502-D S502-D S502-D S502-D S502-D S502-D S503-D S503-D S503-D S503-D S503-D S503-D S503-D S503-D B 7.85 B Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds 0, D AC DC multiple of rated current.36 Discount schedule CB0 Low Voltage Products & Systems

37 S Y/277 VAC S500 Series seconds S50-D20 S502-D3 S503-K6 K 0, AC DC multiple of rated current K UL 077 CSA C22.2 VDE 064 IEC-898 Rated Catalog List Delivery Wgt. oz. current number price class ( Pc.) pole S50-K0.5 $ S50-K S50-K S50-K S50-K S50-K S50-K S50-K S50-K S50-K S50-K B S50-K S50-K S50-K S50-K S50-K S50-K S50-K S50-K S50-K S50-K pole S502-K S502-K S502-K S502-K S502-K S502-K S502-K S502-K S502-K S502-K3 356 B S502-K S502-K S502-K S502-K S502-K S502-K S502-K S502-K S502-K S502-K S502-K pole S503-K S503-K S503-K S503-K S503-K S503-K S503-K S503-K S503-K S503-K3 58 B S503-K S503-K S503-K S503-K S503-K S503-K S503-K S503-K S503-K S503-K S503-K Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Low Voltage Products & Systems Discount schedule CB0.37

38 S500 Series S50UC-B40 S502UC-B6 S500UC 600Y/277 VAC 600 VDC B Rated Catalog List Delivery Weight current number price class (oz.) pc pole 6 S50UC-B6 $ S50UC-B S50UC-B S50UC-B S50UC-B S50UC-B C S50UC-B S50UC-B S50UC-B S50UC-B pole UL 077 CSA C22.2 VDE S502UC-B S502UC-B S502UC-B S502UC-B S502UC-B S502UC-B S502UC-B S502UC-B S502UC-B S502UC-B C 7.85 Rated Catalog List Delivery Weight current number price class (oz.) pc 3 pole 6 S503UC-B6 $ S503UC-B S503UC-B S503UC-B S503UC-B S503UC-B C S503UC-B S503UC-B S503UC-B S503UC-B pole 6 S504UC-B S504UC-B S504UC-B S504UC-B S504UC-B C S504UC-B S504UC-B S504UC-B S504UC-B S504UC-B63 64 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time S503UC-B50 0, B seconds AC DC multiple of rated current.38 Discount schedule CB0 Low Voltage Products & Systems

39 S500 UC 600Y/277 VAC 600 VDC S500 Series K VDE UL 077 CSA C S50UC-K0.5 S502UC-K0.5 S503UC-K0.5 Rated Catalog List Delivery Weight current number price class (oz.) pc pole S50UC-K0.5 $ S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K C S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K S50UC-K pole S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K S502UC-K C 7.85 Rated Catalog List Delivery Weight current number price class (oz.) pc 3 pole S503UC-K0.5 $ S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K C S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K S503UC-K pole S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K3 996 C S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K S504UC-K , S504UC-K0.5 UC-K Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time seconds DC multiple of rated current Low Voltage Products & Systems Discount schedule CB0.39

40 S500 Series Accessories S500-H Auxiliary contacts Electrical Catalog List Delivery Wgt. oz. accessories number price class (pc.) Auxiliary contacts N.O./ N.C. S500-H 2 N.O. S500-H20 $ 84 B 2. 2 N.C. S500-H02 For field mounting left side Bell alarm with auxiliary contacts N.O./ N.C. S500-S 2 N.O. S500-S20 92 B 2. 2 N.C. S500-S02 For field mounting left side Handle mechanism S500-RD3 00 B 6.5 For use with -4 pole S500 MCBs and disconnect switch selector handles with 5mm shafts Electrical Catalog List Delivery Wgt. oz. accessories number suffix price class (pc.) Undervoltage release 2 V UA2 24 V UA24 48 V UA48 0 V UA0 230 V UA V UA500 Factory mount only. Shunt trip 2 V AL2 24 V AL24 48 V AL48 0 V AL0 230 V AL V AL500 Factory mount only. $ 266 B B 5.7 S500-RD3 Front mounting kit For pole S500-ME to 3 poles S500-ME2 70 A 2.9 to 7 poles S500-ME Power feed terminal Accepts into 2/0 AWG S500-K2 25 A 2 Suggested order quantity is 5. S500-K2 S500-BB38 Busbars 3 phase L, L2, L3 Amp rating Number Busbar End cap Catalog List Delivery Suggested of length catalog number price class order qty. poles (mm) number quantity 3 x S500-BB38 $ x S500-BB44 2 A 3 x S500-BB Busbar end caps Electrical Catalog List Delivery Wgt. oz. accessories number price class (pc.) S500-EK $ 25 A 0 Weight (ozs) Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.40 Discount schedule CB8 Low Voltage Products & Systems

41 Technical data S500 Series Item S500-B, C, D S500-K Approvals: UL CSA C No.235 C No. 235 VDE 064/ /6.78 IEC No. of poles:,2,3, +N, +NA,2,3, +N, +NA Tripping characteristic: B.C.D. K Rated currents: 6 to 63A 0. to 45A Rated voltage: UL/CSA single pole 277VAC 277VAC UL/CSA multi pole 600YVAC 600YVAC IEC single pole 690VAC 690VAC Rated interrupting capacity: Single pole 6-25A 30KA/240VAC A 30KA/240VAC KA/277VAC KA/277VAC 32-63A 8KA/240VAC 26-45A 8KA/240VAC KA/277VAC KA/277VAC Multi-pole 6-63A KA/480VAC A KA/480VAC 6KA/600VAC 6KA/600VAC Frequency: 50/60 Hz 50/60Hz Mounting position: optional optional Standard mounting: 35mm DIN rail 35mm DIN rail Terminals: Conductors from 6-4AWG Conductors from 6-4AWG (-25sq mm) (-25sq mm) Service life at rated load: 20,000 operations 20,000 operations Calibration temperature: 40 C 40 C Approvals: UL CSA VDE No. of poles: Tripping characteristic: Rated currents: Rated voltage: UL single pole UL multi pole IEC multi pole Item S500UC-B, K 077 C ,2,3, 4 B, K B: 6 to 63A K: 0.5 to 45A 277VAC/250VDC 600VAC/600VDC 690VAC/750VDC Rated interrupting capacity: B single pole: 6 25A 8KA/240VAC KA/277VAC 30KA/250VDC 32 63A 30KA/240VAC KA/277VAC 30KA/250VDC B two-pole: 6 63A KA/480VAC 6KA/600VAC 30KA/500VDC B three-pole: 6 63A KA/480VAC 6KA/600VAC 30KA/600VDC K single pole: A 30KA/240VAC KA/277VAC 30KA/250VDC 32 45A 8KA/240VAC KA/277VAC 30KA/250VDC K two-pole: A KA/480VAC 6KA/600VAC 30KA/500VDC K three-pole: A KA/480VAC 6KA/600VAC 30KA/600VDC Frequency: Mounting position: Standard mounting: Terminals: Service life at rated load: 50/60Hz optional 35mm DIN-rail Conductors from 6 to 4AWG (-25sq mm) 20,000 operations Low Voltage Products & Systems.4

42 S500 Series Approximate dimensions Inches [Millimeters] S CL S500-RD3 Handle mechanism S500 Front mounting kit CL CUT-OUT "L" CL 0.24 D 6D L L L Low Voltage Products & Systems

43 Galaxie circuit breakers GD, GH, GN & GV Galaxie circuit breakers Description Galaxie circuit breakers are door mounted for AC and DC applications. The breakers offer thermal-magnetic and magnetic-only trip protection. For the worldwide market, the Galaxie breakers carry UL, CSA, IEC, CE and many other agency approvals and certifications. Features Convenient actuators: Switch type, rocker switch & pushbutton Various termination mountings Tropicalization protection 480Y/277 VAC UL 077 Recognized supplemental protective device. UL File # E7574. Low Voltage Products & Systems.43

44 Galaxie circuit breakers GD, GH, GN & GV Series circuit breakers Fitted, unpluggable or projecting type Catalog number explanation Circuit Breakers SERIES GD Standard Galaxie AC 240/45 V 50/60 Hz can be used at 48 V DC max. GH High rupturing capacity Galaxie AC 240/45 V 50/60 Hz GN Special Galaxie 00 V DC max. GV Special Galaxie 50 V DC max. GA Severe environment Galaxie (i.e. military use) consult us VERSIONS U One-pole ( protected pole) B Two-pole (2 protected poles) T Three-pole (3 protected poles) Q Four-pole (4 protected poles) +N Two-pole ( protected pole + neutral) 3+N Four-pole (3 protected poles + neutral) RATING (In : Amps) Heavy duty types : ratings according to NF EN Other ratings, consult us. MODELS L Thermal-magnetic - Curve B according to NF EN U Thermal-magnetic - Curve C according to NF EN D Thermal-magnetic - Curve D according to NF EN Ratings 6 to 32 A S Thermal-magnetic (series GN and GV only) according to NF F 6200 T Thermal (except series GH) FASTENINGS AND OPERATIONS OPTIONS RATING ENGRAVED J On resetting button METAL THREADED BUSHING W For fastening and operations Tightening torque : 3 Nm max. (compulsory with option K) CIRCUIT BREAKER SERIES GD MODEL D 2 R With adjustable thermal protection (Not possible with option K) MECHANICAL IMPACT V 50 g E 00 G TROPICALIZATION T (Compulsory with option E 00) THERMAL PROTECTION C Temperature compensated from + 20 C to + 60 C K Temperature compensated from - 40 C to + 85 C series GD, GH and GA (Compulsory with Option W) AUXILIARY CONTACT FOR POSITION SIGNALLING O/F P on pole P2 on 2 poles P3 on 3 poles P4 on 4 poles See next page 2 Series GD, Model D only TERMINATIONS EXAMPLE : Circuit breaker Series : Galaxie standard AC - Version : 2 protected poles - Rating : 0 A - Model : magnetic-thermal, curve C - Fastenings and operations : Threaded bushing flush type 2 buttons - Terminations : Screws and back connectors - With Options Auxiliary for position signalling O/F : on 2 poles - Tropicalization has reference GDB0U0703 P2T GD B 0 U P2 - T Low Voltage Products & Systems

45 Technical data Galaxie circuit breakers Characteristics SERIES GD SERIES GH SERIES GN SERIES GV Rated voltage + neutral version One pole version Multipole version One pole and two pole version Interrupting capacity According to standard IEC 898 According to standard NF F62 00 Other characteristics Life, number of cycles (On+Off) Dielectric withstanding voltage UL, CSA : For list of certified products : consult us Circuit breakers NF F62 00 : consult us 240 V AC (50/60 Hz) 240/45 V AC (50/60 Hz) 240/45 V AC (50/60 Hz) 45 V AC (50/60 Hz) 45 V AC (50/60 Hz) 48 V DC max. 00 V DC max. 50 V DC max A A (models U and D: rating 5 A) A (model L: rating 0 A) 000 A (48 V DC max.) 500 A 000 A (48 V DC max.) 0 In cal. < 5 A ; 20 In cal > 5 A 0 In cal. < 5 A ; 20 In cal > 5 A 0 In cal. < 5 A ; 20 In cal > 5 A V rms V rms V rms V rms Tripping curves () (2) S Curve B : 3 In < S < 5 In - Curve C : 5 In < S < 0 In - Curve D : 0 In < S < 20 In < In Nominal current 0. to 2 A : 5 In < S < 0 In - 3 to 32 A : 7 In < S Mechanical shock Ambient temperature 30 g. 30 g. 30 g. 30 g. -5 C to 40 C -5 C to 40 C -25 C to + 70 C -25 C to + 70 C Low Voltage Products & Systems.45

46 Galaxie circuit breakers Approximate dimensions Fastenings and operations N o Pole Pole Pole Pole Pole N N 2 N N 2 N 3 Width 2 Widths 3 Widths Fastenings / Operations Size A , Size C Terminations Size B Fastenings and operations N o Four-pole circuit breaker : Fastening and operation N o 05 only NOTE : Neutral on pole N any Fastenings and operations Pole Pole Pole Pole Pole Pole Pole Pole Pole N 2 N N 3 N 2 N N 4 N 3 N 2 N Width 2 Widths 3 Widths = handle 4 Widths = 2 handles Fastenings and operations (3 poles max. except 02 : 2 poles and 05 : 4 poles) P R O J E C T I O N M O U N T I N G S C R E W F L U S H M O U N T I N G Maximum thickness of mounting panel : 3 mm. 3 mm. 3 mm. 6 mm. 6 mm. 6 mm. 6 mm Terminations Tightening torque :,8 Nm max.,8 Nm max.,8 Nm max. 3 Nm max A max. 240 A max. 6 A max. 6 A max. 6 A max. Except Fastening 08 2 poles max. 2 poles max. 2 poles max..46 Low Voltage Products & Systems

47 compact Residual current devices F200, F670 series Residual current devices 2 Pole 4 Pole Description RCDs provide ground fault equipment protection by monitoring the leakage of current to ground. The F200 and F670 series will trip when ground faults are detected in excess of the GF trip rating of the device. These devices provide GF protection only and are used in series with standard MCBs which provide overload and short circuit protection. The F200 and F670 series can be used as a main device providing GF protection for several MCB branch devices. The F200 and F670 series are UL053 recognized for use in 480Y/277VAC applications. The F202 and F672 is for use in single phase/two wire or two wire systems. The F204 and F674 is for use in three phase/four wire systems. The F200 and F670 series RCDs replace the F360, F370 and F660 series with no change in fit, form or function. The F200 and F670 have a profile similar to the S2 MCBs and can be used with the MCB busbars. Low Voltage Products & Systems.47

48 Residual current devices F202, F672 F204, F674 F200 & F670 Residual current devices Breaker GF trip Rated Catalog List Delivery Suggested Wgt. oz level current number price class order qty ( Pc.) F202 Two pole 0mA 6 F202AC-6/0.0 $ 500 F Y/277VAC 30mA 25 F202AC-25/ F202AC-40/ F202AC-63/ F672-80/ F672-00/ Above devices are UL 053 recognized and IEC 008 approved. 00mA 25 F202AC-25/ F202AC-40/ B F202AC-63/ F672-80/ F672-00/ mA 25 F202AC-25/ F202AC-40/ F202AC-63/ F672-80/ F672-00/ F204 Four pole 30mA 25 F204AC-25/ F Y/277VAC 40 F204AC-40/ F204AC-63/ F674-80/ F674-00/ F674-25/ mA 25 F204AC-25/ F204AC-40/ F204AC-63/ F674-80/ F674-00/ B F674-25/ mA 25 F204AC-25/ F204AC-40/ F204AC-63/ F674-80/ F674-00/ F674-25/ mA 25 F204AC-25/ F204AC-40/ F204AC-63/ Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.48 Discount schedule CB Low Voltage Products & Systems

49 Accessories F200 Residual current devices Auxiliary contacts Electrical For Catalog List Delivery Suggested Wgt. oz. accessories use on: number price class order quantities ( pc.) For field mounting: right side F200 S2C-H6R $ 36 A.4 Form C NO/ NC The auxiliary contacts will signal whether the breaker is in the ON or OFF position. The contacts are rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. Wire size: 8 AWG to 6 AWG. S2C-H6R Bell alarm For field mounting, right side F200 S2C-S/H6R 48 A.4 The bell alarm includes a set of contacts that will only signal when the breaker has tripped. Typically the contacts would be connected to an alarm or bell to signal the operator that an overcurrent trip has occured. The bell alarm also includes a test button for testing the alarm contacts without opening the breaker. The contact is rated 2A/277 VAC and.5a/25 VDC. Minimum operating voltage is 24 VAC/VDC. * Combination bell alarm/auxiliary contact S2C-S/H6R Shunt trip For field mounting, right side F200 S2C-A A: 2-60 VAC (2-60VDC) S2C-A2 A2: 0-45 VAC (0-250 VDC) 38 A 5.2 For remote tripping of breaker, a shunt trip device can be added to the MCB. The solenoid device opens the breaker after control voltage is applied. Shunt trips are available for on control system voltage (2-45 VAC/VDC). S2C-A_ Undervoltage release For field mounting, right side 2 VDC S2C-UA2 24 VAC S2C-UA24 48 VAC F200 S2C-UA48 0 VAC S2C-UA0 26 A VAC S2C-UA VAC S2C-UA400 When control voltage drops below approximately 50% of rated voltage, the UVR opens the breaker. The breaker can not be operated unless proper control voltage is first applied to the UVR coil. Similar in size and mounting to the shunt trip accessory. Factory mounting All accessories can be easily mounted in the field. For factory mounting of any accessory devices, add $30 list to total price per breaker. To create complete catalog number, take suffix of accessory device following S2C- and add suffix to end of breaker part number. Multiple suffixes must be added in alphabetical order. S2C-UA_ Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time Please consult factory for F670 accessories. Low Voltage Products & Systems Discount schedule CB8.49

50 Residual current devices Technical data F200, F670 F200AC F670 Electrical features Standards UL 053 & IEC 6008 UL053 & IEC 6008 Poles 2P, 4P 2P, 4P Rated current In 6,25,40,63 AMPS 2P- 80,00 4P- 80,00,25 Rated Voltage Ui 480Y/277 VAC 480Y/277 VAC Max operating voltage of curcuit test 254 (440 for F200 left neutral) 254 (440 for left neutral) Min operating voltage of circuit test 0 ( 95 for F200 left neutral) 0 ( 95 for left neutral) Rated Frequency Hz Hz Rated conditional Hz Hz Short-circuit current 0 KA 0 KA Rated residual breaking capacity KA 2 KA Rated impulse withstand voltage (.2/50) Uimp 6 KV 6 KV Power- frequency voltage dielectric strength 2.5 KV 2.5 KV Surge current resistance acc. To VDE 0432 Part 2 (wave 8/20) 250 AMPS 250 AMPS Mechanical features Toggle Blue sealable in ON-OFF position Blue sealable in ON-OFF position Contact position indicator yes yes Electrical Life Mechanical life Ambient temperature -25 C +55 C -25 C +55 C Storage temp. -40 C +70 C -40 C +70 C Installation Terminal Type failsafe bidirectional cylinder-lift terminal at top and bottom (shock protected) Terminal size top/bottom per cable 6 AWG Max. 6 AWG Max. Tightening torque 7.5 in-lb max. 7.5 in-lb max. mounting 35mm din rail by means of fast clip 35mm din rail by means of fast clip Connection From top & bottom From top & bottom Withdraw from busbar Possible without the use of tools Possible without the use of tools Approximate dimensions 2 Pole mm 85x69x35 MM 85x69x35 MM 4 Pole mm 85x69x70 MM 85x69x70 MM Weight 2 Pole g 200g 200g 4 Pole g 350g 350g Combination with auxiliary elements Auxiliary contact yes yes signal contact/ auxiliary switch yes yes shunt trip yes yes undervoltage release yes yes.50 Low Voltage Products & Systems

51 Inches [Millimeters] Approximate dimensions Circuit diagrams F200, F670 Residual current devices Approximate dimensions Circuit diagrams To use on 3p/3w systems, add jumper between 4 and 8N for operation of test button. Low Voltage Products & Systems.5

52 Residual current devices Notes.52 Low Voltage Products & Systems

53 compact Modular DIN rail components E220 - E270 Series Modular DIN rail components Description Safe connection by box terminals Captive screws with Pozidrive slotted head, Pozidrive system, Gr. Snap-on labels available Quick mounting with snap-on clip, easily accessible and detachable at the bottom Protection against unintentional direct touch System approach for control and circuit protection Compact size that dimensionally matches the S2 MCB series Control and pilot functions can be along side protective devices DIN rail mounted with 45mm front opening For use in auxiliary and logic devices Provide additional user functions for system control and operation Include pushbuttons, indicating lights and selector switches ABB System Pro M compatibility Most devices are both UL 508 recognized and are IEC compliant Labeled with the CE Mark Low Voltage Products & Systems.53

54 Modular DIN rail components E22 & E222 Switches, 240VAC 6 & 25A E22-0 Type Rated Catalog List Delivery Suggested Weight (Oz.) current number price schedule order qtys piece Switches N.O. + N.C. 6 E22- $ 90 2 N.O. + 2 N.C. 6 E B N.O. + N.C. 6 E N.O. 6 E N.O. 6 E B N.O. 6 E N.O. 6 E N.O. + N.C. 25 E N.O. 25 E N.O. 25 E B N.O. 25 E N.O. 25 E Form C switches Change-over contact 6 E B Change-over contacts 6 E22-6/ Change-over contact 25 E B Form C switches (I-O-II, Hand-OFF-Automatic) Pole 6 E B Pole 6 E22-4/ Pole 25 E B Note: Above devices are UL 508 recognized and IEC certified. A300 pilot duty UL file # E7252 Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.54 Discount schedule CB20 Low Voltage Products & Systems

55 E24 - E274 Disconnect switches 45, 63, 80 & 00A Modular DIN rail components Page Deleted 4/24/06 Low Voltage Products & Systems.55

56 Modular DIN rail components E225 - E229, E0 Pilot devices Type Catalog List Delivery Pack Weight (Oz.) number price schedule units pcs. piece Pushbutton, N.O. + N.C. contact Grey Red Green Yellow Black Blue E225-B E225-C E225-D E225-E E225-F E225-G $ 75 A 0.94 E225-F Illuminated pushbutton, N.O. contact with lamp, 20 VAC Clear E227-0B/0 Red E227-0C/0 Green E227-0D/0 00 Yellow E227-0E/0 Blue E227-0G/0 A 0.94 E227-0E E233-20/60 Pilot light with lamp, 20 VAC Clear E229-B/0 Red E229-C/0 Green E229-D/0 93 A 0.59 Yellow E229-E/0 Blue E229-G/0 Lamps 24 VAC/DC E0/24 20 VAC/DC E0/0 24 A VAC/DC E0/220 Note: Above devices are UL 508 recognized and IEC certified. UL file # E7252 Special features Safe connection via box terminals Captive screws with Phillips/Slotted head, Posidriv system, Gr. Snap-on labels available Protection against unintentional touch acc. to DIN VDE 006 Part 00 Lenses and pushbuttons in six colors Elapsed time meter Type Catalog List Delivery Pack Weight (KG) number price schedule units pcs. piece 24 VAC, 60 Hz E233-24/60 B 20 VAC, 60 Hz E233-20/60 $ 30 A VAC, 60 Hz E /60 B Non-resettable 00,000 hours ( ) UL file #7252 Sockets Type Catalog List Delivery Pack Weight (KG) number price schedule units pcs. piece E75 Socket, 250 VAC, 50/60 Hz E73 $ 57 B 0.2 Italian standard Socket, 250 VAC, 50/60 Hz E74 $ 57 B 0.2 French standard Socket, 250 VAC, 50/60 Hz E75 $ 57 B 0.2 Schuko standard Socket w/cover, 250 VAC, 50/60 Hz E75-C $ 57 B 0.2 Schuko standard E75-C Delivery Class A - Standard item, stock to 2 weeks lead time B - Stock to 4 weeks lead time C - 6 to 8 week lead time.56 Discount schedule CB20 Low Voltage Products & Systems

57 Digital meters Modular DIN rail components Measuring instruments Type Catalog List Delivery Pack Weight (KG) number price schedule units pcs. piece Digital timer, 230 VAC, 50/60 Hz DTS7/ $ 422 B 0.3 Voltmeter 600 VAC, Hz VLMD B 0.3 Ammeter A, AMTD- 50 B A, Hz DTS7/ Transformer, 230 VAC, 50/60 Hz TM5/2 35 B VAC sec VLMD--2 TM5/2 Low Voltage Products & Systems.57

58 Modular DIN rail components Technical data Components for quick mounting onto DIN rails (35mm) Mounting depth: 68mm Mounting width:, 2, 3 and 4 pole switches = 7.5mm (= module) E220 Switches, 6 & 25A Switching capacity:.25 I n,.u n, cos j = 0.6 Short-circuit withstanding capacity: 3 ka, 380V, cos j = 0.9 Toggle sealable: In ON and OFF positions Connection cross-sections: Up to x 6mm 2 or 2 x 2.5mm 2 Rated AC voltage: 240 VAC UL/CSA (E7252) 250/440 VAC IEC E240/270 Disconnect switches, 45, 63, 80, & 00A Switching capacity:.25 I n,.u n, cos j = 0.3 Short-circuit withstanding capacity: E240 = 0kA, E270 = 25kA RMS Connection cross-sections: E240 up to 25mm 2 E270 up to 50mm 2 Rated AC voltage: 240/400/45 VAC E Series components for quick mounting onto DIN rails (35mm) Mounting depth 68mm Mounting width: 7.5mm (= module) Color: RAL 7035, grey Connection cross sections: Up to X 6mm 2 or 2 X 2.5mm 2 Rated current: 6A Rated voltage: 250 VAC IEC Rated voltage: 240 VAC UL/CSA (E7252) Terminal markings NO&2NC Switches 3NO&NC 2NO NO 2NO 3NO Disconnect switches 4NO I II 3 0 I II NO 2NO 3NO Pole 2 Pole Pole 2Pole Illuminated pushbutton Form "C" switches Form "C" switches (Hand - OFF- Auto) Terminal assignments for pushbuttons and indicator lights MAX 2W 2 2 MAX 2W NO&NC NO Illuminated NO Pushbutton Pilot light.58 Low Voltage Products & Systems

59 Inches [Millimeters] Approximate dimensions Modular DIN rail components E Pilot light Pushbutton E220, 6 & 25A E E240/ Low Voltage Products & Systems.59

60 Modular DIN rail components E73 - E75 Approximate dimensions DTS VLMD, AMTD TMS.60 Low Voltage Products & Systems

61 Transient voltage surge suppressors Transient voltage surge supressors TVSS, OVR range Description Compact DIN rail mounting Broad range, 2, 3, & 4 pole versions Replaceable plug cartridges Finger safe 5, 40, 65 & 00 ka versions Three position visual status indication Auxiliary contact for remote signalling UL 49, File # E & E22406 Low Voltage Products & Systems.6

62 Transient voltage surge suppressors General points on lightning and its risks Causes of transient overvoltages The most serious consequences of lightning are the death of people and farm animals, and the destruction of equipment: telephone lines, transformers connected to the electrical distribution network, electrical meters, household appliances, etc. At the same time, the growing amount of equipment incorporating very sensitive electronic devices increases the number of incidences linked to lightning. Within companies, if office automation equipment or machines (in factories) are put out of action, it nearly always leads to operating losses, the cost of which is much more than that of the damaged equipment. For example, if a bank s computers are no longer operational, it suffers large operating losses. For the general public, the damage is mainly material: computer, household appliances, home cinema, etc. ROBUSTNESS OF EQUIPMENT Causes of transient overvoltages A transient overvoltage is a voltage peak with a maximum duration of less than one millisecond. There are two possible causes of overvoltages on electrical networks: natural causes (lightning), other causes due to equipment or switching devices. PROPAGATION OF DISTURBANCES Natural overvoltages on low voltage networks are caused by direct lightning strikes. The high level of energy contained in a direct lightning strike on a lightning conductor or an overhead low voltage line leads to considerable damage of the installation. The overvoltage can be over 20 times the nominal voltage. Operating or switching overvoltages linked to a network s equipment create overvoltages of a lower level (3 to 5 times the nominal voltage) but occur much more frequently, thus causing premature ageing of the equipment. Three categories of overvoltage propagate on low voltage networks: direct lightning strikes, indirect effects of lightning strikes, operating or switching overvoltages. Propagation of overvoltages by electrical networks (power and low current).62 Low Voltage Products & Systems

63 General points on lightning and its risks Causes of transient overvoltages Transient voltage surge suppressors Overvoltages due to direct lightning strikes These can take two forms: When lightning strikes a lightning conductor or the roof of a building which is earthed, the lightning current is dissipated into the ground. The impedance of the ground and the current flowing through it create large difference of potential: this is the overvoltage. This overvoltage then propagates throughout the building via the cables, damaging equipment along the way. When lightning strikes an overhead low voltage line, the latter conducts high currents which penetrate into the building creating large overvoltages. The damage caused by this type of overvoltage is usually spectacular (e.g. fire in the electrical switchboard causing the destruction of buildings and industrial equipment) and results in explosions. Direct lightning strike on a lightning conductor or the roof of a building Direct lightning strike on an overhead line Overvoltages due to the indirect effects of lightning strikes The overvoltages previously mentioned are also found when lightning strikes in the vicinity of a building, due to the increase in potential of the ground at the point of impact. The electromagnetic fields created by the lightning current generate inductive and capacitive coupling, leading to other overvoltages. Within a radius up to several kilometres, the electromagnetic field caused by lightning in clouds can also create sudden increases in voltage. Although less spectacular than in the previous case, irreparable damage is also caused to so called sensitive equipment such as fax machines, computer power supplies and safety and communication systems. Increase in ground potential Magnetic field Electrostatic field Low Voltage Products & Systems.63

64 Transient voltage surge suppressors Different types of surges Equipment containing electronic switching components is also likely to generate electrical disturbances comparable to overvoltages. The consequences of which on sensitive equipment, albeit not visible, are no less detrimental: premature ageing and unpredictable or fleeting breakdowns. Operating overvoltages are produced when reactive or capacitive equipment is switched on and off. Furthermore, interrupting factory production, lighting or transformers can generate overvoltages which will themselves cause greater damage to nearby electrical equipment. Direct lightning strikes Indirect lightning strikes Operating overvoltages Harmonics Micro breaks Temporary phenomenon Duration > 200ms Too long for TVSS Transient phenomenon Duration < ms TVSS needed Representation of the various disturbances on electrical networks Different type of power supply disturbances Atmospheric discharges Industrial interferences Switching operations on the power distribution system Main effects Destruction of the equipment Premature aging Incorrect operations.64 Low Voltage Products & Systems

65 OVR Range Main features Transient voltage surge suppressors TVSSs protect installations by limiting transient overvoltages and run-off lightning currents for electric and electronic equipment. They are divided into three families: Type 2 TVSSs provide protection for equipment against transient overvoltage and they are installed in the Main Switch Board (MSB), or in the Sub-Distribution Board (SDB). In addition to the standard TVSSs, two options are available: the Safety reserve system and the remote indication (TS), in order to ensure a preventive maintenance of the installation. ABB TVSS (OVR range) offer the same plus advantages of the other compact devices, in order to get a perfect compatibility with all the modular range of products. All these TVSS products comply with the international standard IEC and the European standard EN They also comply with UL 49 and CSA C22.2. ABB safety reserve system Contact for alarm connection Pluggable unit / replacement modules DIN rail unit, easy installation and wiring Low Voltage Products & Systems.65

66 Transient voltage surge suppressors Technical data OVR range Electrical features Mechanical features Installation Dimensions and weight Technical Features Type 2 Standards IEC / EN / UL99 / CSA Type / test class T2 / II Poles P / P+N / 3P / 3P+N / 4P Types of networks TNS - TT - TNC - IT / Wye / Delta Type of current A.C. Nominal voltage Un V All US network voltages Max. cont. operating voltage Uc (L-N / L-PE / N-PE) V 50 / 275 / 320 / 440 / 550 / 660 Voltage protection level Up at In (L-N / L-PE / N-PE) kv 0.6 /.2 /.4 /.8 / 2.5 / 2.9 Nominal discharge current In (8/20) ka 5 / 5 / 20 / 30 Maximal discharge current Imax (8/20) ka 5 / 40 / 65 / 00 Impulse current Iimp (0/350) ka / Follow current If i ka None Operating current Ic ma < Short circuit withstand Icc ka 50 Disconnector gg - gl fuse A 6-25 curve C circuit breaker A 0-40 curve K circuit breaker Stocking temperature C -40 to +80 Operating temperature C -40 to +80 Degree of protection IP 20 Fire resistance according to UL 94 V2 Material of Housing PC grey RAL 7035 Maximal altitude m 2000 Integrated thermal disconnector Yes State indicator Yes Compatibility with OVR Sign Yes Safety reserve Option TS remote indicator Option Wire range L/N solid wire mm stranded wire mm Stripping length L/N mm 2.5 Tightening torque L/N Nm 2 Wire range PE solid wire mm stranded wire mm Stripping length PE mm 2.5 Tightening torque PE Nm 2 Pole dimensions (H x D x W) mm 85 x 58 x 7.5 Pole weight g 20 Technical Features of the integrated auxiliary contact Electrical features Contact complement NO ( make contact), NC ( normally closed contact) Min. load 2V D.C. - 0 ma Max. load 250V A.C. - A Installation Connection cross-section mm Low Voltage Products & Systems

67 OVR Range Single pole Transient voltage surge suppressors Transient voltage surge suppressor Function: TVSS provides protection for equipment against transient overvoltage (indirect lightning strike) that occur on the electrical network (mains); the maximum discharge current (Imax) ranges from 5 to 00 ka per pole, based on MOV technology. Application: residential, commercial, industrial Standard: CEI / EN / UL 49 / CSA 8/20 current wave Type 2 - Surge Protection Devices Single pole Max Discharge Current (KA) Nominal Voltage (V) MOV Voltage (V) Voltage Protection Level Up (KV) Catalog number List price OVR 5 50 $ 230 OVR 5 50 s P OVR OVR P TS OVR OVR OVR P OVR OVR OVR s P 440 OVR s P TS OVR P 320 OVR s P 345 OVR s P TS 400 OVR P 320 OVR s P 350 OVR s P TS 405 OVR OVR s P 350 OVR s P TS OVR OVR s OVR s OVR s P OVR s P 490 OVR s P TS OVR s P 495 OVR s P TS OVR s P 465 OVR s P TS OVR s OVR s OVR s P 830 OVR s P TS OVR s P 890 OVR s P TS 025 OVR s 800 OVR s P 870 OVR s P TS 005 Network N Single phase (left), neutral (right) 3N Three phase (left), neutral (right) N Neutral (left), single phase (right) N3 Neutral (left), three phases (right) 3L Three poles 4L Four poles Nothing Single pole Max. discharge current 8/20 I max (ka) OVR N s P TS TS Integrated remote indication P Pluggable unit Nothing: Single block s with safety reserve Max. continuous operating voltage U c (V) Low Voltage Products & Systems Discount schedule CB5.67

68 Transient voltage surge suppressors OVR TVSS Multi-pole Transient voltage surge suppressor Function: TVSS provides protection for equipment against transient overvoltage (indirect lightning strike) that occur on the electrical network (mains); the maximum discharge current (Imax) ranges from 5 to 00 ka per pole, based on MOV technology. Application: residential, commercial, industrial Standard: CEI / EN / UL 49 / CSA 8/20 current wave Max Discharge Current (KA) Nominal Voltage (V) MOV Voltage (V) Voltage Protection Level Up (KV) Catalog number List price OVR N 5 50 $ 365 OVR N 5 50 s P TS 665 OVR 3N OVR 3L P 625 OVR 3N OVR 3N OVR N s P 665 OVR N s P TS 935 OVR 3N s P TS 60 OVR 3N s P 20 OVR 3L s P 950 OVR 3N P OVR 3N s P 250 OVR 3N s P TS OVR 3N s P OVR N s P 000 OVR 3N s P 535 OVR 3N s P TS 640 OVR 3L s P 045 OVR 3N s P 280 OVR 3N s P 650 OVR 3N s P TS 900 OVR 3N s P 245 OVR 4L s 320 OVR 3N s P 3200 OVR 3N s P TS 3600 Network N Single phase (left), neutral (right) 3N Three phase (left), neutral (right) N Neutral (left), single phase (right) N3 Neutral (left), three phases (right) 3L Three poles 4L Four poles Nothing Single pole Max. discharge current 8/20 I max (ka) OVR N s P TS TS Integrated remote indication P Pluggable unit Nothing: Single block s with safety reserve Max. continuous operating voltage U c (V) Discount schedule CB5 Low Voltage Products & Systems

69 OVR Range Very low voltage transmission lines protection Transient voltage surge suppressors Transmission line surge arresters (OVR TC) provide protection against transient overvoltages for equipment connected to telephone lines (digital or analog) & current loops. Standards Info: Modular low current surge arresters comply with IEC / UL 49. Schematic diagrams L L l L2 L2 l2 OVR TC 06 V OVR TC 200 V in parallel OVR TC / xx V / 200 FR in series Dimensions Dimensions (mm) W H D OVR TC (all models) Connection L L2 L L2 OVR TC 200 FR OVR TC 200 V OVR TC 200 FR OVR TC 48 V OVR TC 24 V OVR TC 2 V OVR TC 06 V OVR TC 200 V in parallel l l2 OVR TC / xx V / 200 FR in series Fixing Simply clips onto DIN rail. Pratical info: Telecom and dataline protection surge arresters are installed in electrical switchboards or enclosures using DIN rail. Low Voltage Products & Systems.69

70 Transient voltage surge suppressors Technical data Electrical characteristics 6 V 2 V 24 V 48 V 200 V 200 V OVR TC 06 V OVR TC 2 V OVR TC 24 V OVR TC 48 V OVR TC 200 V OVR TC 200 FR Types of network Communication Communication Communication Communication Communication Communication Number of pairs Type of protection Series Series Series Series Parallel Series Type of current Low currents Low currents Low currents Low currents Low currents Low currents Nominal voltage: U n 6 V 2 V 24 V 48 V 200 V 200 V Max cont operating voltage: U c 7 V V 27 V 53 V 220 V 220 V Voltage protection level: U p at I n 5 V 20 V 35 V 70 V 700 V 300 V Nominal discharge current: I n (8/20) 5 ka 5 ka 5 ka 5 ka 5 ka 5 ka Maximum discharge current: I max (8/20) 0 ka 0 ka 0 ka 0 ka 0 ka 0 ka Bandwidth 0 MHz 2 MHz 4 MHz 6 MHz 00 MHz 3 MHz Operating current: I c 20 ma 20 ma 20 ma 20 ma - 20 ma Degree of protection IP 203 IP 203 IP 203 IP 203 IP 203 IP Hz withstand (5 mn) 0 A 0 A 0 A 0 A - 0 A Mechanical characteristics L/N connection terminals: solid wire mm 2 stranded wire mm 2 PE connection terminal: solid wire mm 2 stranded wire mm 2 Integrated thermal disconnector Yes No Yes End of life indicator Yes No Yes Compatibility with OVR Sign Yes No Yes Miscellaneous characteristics Storage temperature -40 C to +80 C Operating temperature -40 C to +80 C Maximum altitude 2000 m Case material PC grey RAL 7032 Insulating material UL94 V0 classification Reference standard IEC / UL 49 Weight 50 g.70 Low Voltage Products & Systems

71 Installation rules Principles of coordination for TVSS Transient voltage surge suppressors The first surge arrester does not provide effective protection for the whole installation by itself. Certain electrical phenomena can double the protection s residual voltage if cable lengths exceed 0m. Surge arresters must be coordinated when they are installed refer to the tables below. Coordination required if: The first surge arrester does not reach the protection voltage (U p ) by itself. The first surge arrester is more than 0m away from the equipment to be protected. The first surge arrester diverts most of the current to the ground and the remaining surge current is diverted to the ground by the second surge arrester. The value of this remaining surge current gets lower as the distance between both surge arresters gets longer. The lower is the current going through the last surge arrester, the lower is the voltage protection level applied to the downstream equipment. Coordination between Type 2 TVSS units TVSS 65 ka 8/20 L > m ( m minimum between the two devices) TVSS 5 ka 8/20 Low Voltage Products & Systems.7

72 Transient voltage surge suppressors Approximate dimensions OVR range Transient voltage surge suppressor TVSS without TS 63 TVSS with TS pole 3 poles 7,6 52,8 OVR P OVR P OVR P OVR s P TS OVR P OVR s P TS OVR s P TS OVR s P TS OVR 3L P OVR 3L P OVR 3L s P TS OVR 3L s P TS 4 poles 3 poles + Neutral 70,4 OVR 4L P OVR 4L P OVR 4L s P TS OVR 4L s P TS OVR 3N P OVR 3N P OVR 3N s P TS OVR 3N s P TS.72 Low Voltage Products & Systems

73 Technical details Installation rules for TVSS choice of associated breaking devices (fuse/circuit breaker) Transient voltage surge suppressors Choice of disconnector Surge arresters must be associated with upstream short-circuit protection and residual current protection against indirect contact (usually already present in the installation) Function Application Protection against fault currents The breaking device associated with the surge arrester can be either a circuit breaker or a fuse. Its rating should take into consideration the surge arrester s characteristics and the short-circuit current of the installation. Thermal protection Thermal protection is integrated into the surge arrester. Maximum circuit-breaker or fuse protection rating depending on I max and I imp of the surge arrester. TVSS surge arresters Circuit-breaker (curve K) Fuse (gg) 00 ka (8/20) I cc = 300 A to ka 40 A 25 A I cc = ka to 7 ka 40 A 25 A I cc = 7 ka and above 40 A 25 A TVSS surge arresters Circuit-breaker (curve C) Fuse (gg) 65 ka (8/20) I cc = 300 A to ka 30 A 20 A I cc = ka to 7 ka 32 A to 40 A 40 A I cc = 7 ka and above 32 A to 63 A 63 A 40 ka (8/20) I cc = 300 A to ka 25 A 6 A I cc = ka to 7 ka 25 A 25 A I cc = 7 ka and above 25 A to 50 A 50 A 5 ka (8/20) I cc = 300 A to ka 0 A to 25 A 6 A I cc = ka to 7 ka 0 A to 32 A 6 A I cc = 7 ka and above 0 A to 40 A 25 A to 40 A Low Voltage Products & Systems.73

74 Transient voltage surge suppressors Technical details Cabling and installation of Surge Protection Devices in an electrical panel 50 cm rule Remember that a 0 ka lightning current passing through a m length of cable generates 000 Volts. Equipment protected by a surge arrester is subjected to a voltage equal to the sum of the U p voltage of the surge arrester, U d of its disconnector and the sum of the inductive voltages of connecting cables (U+U2+U3). It is therefore essential that the total length (L = L+L2+L3) of the connecting cables is as short as possible (0.50 m). If this length (L = L + L2+L3) exceeds 0.50m, it is necessary to carry out one of the following: Reduce this length by moving the connection terminals. Choose a surge arrester with a lower U p value. Install a second, coordinated surge arrester near the device to be protected so as to adapt the combined U p value to the impulse withstand of the equipment to be protected. Wiring ring surfaces The wires must be arranged in such a way that they are as close to each other as possible (see adjacent diagram) to avoid overvoltages induced by a ring surface between phases, the neutral and the PE conductor. Routing of clean cables and polluted cables During installation, lay clean cables (protected) and polluted cables as shown in the adjacent diagrams. U U D U2 U P U3 L L2 L3 L To avoid magnetic coupling between the different cable types (clean and polluted), it is strongly advised that they are kept apart (> 30 cm) and if a crossing cannot be avoided, it should be at right angles (90 ). Polluted cables D > 30 cm Clean cables Polluted cable Crossing at 90 Clean cable Main circuitbreaker Terminal / MCB Ring surface Surge arrester circuitbreaker Feeder Clean cable Polluted cable D > 30 cm MCB / TVSS D < 30 cm Feeder 2 TVSS / Earth terminal Equipotential grounding: It is critical to check the earth equipotentiality of the various items of equipment. Note: The cross-section of the connecting cables is calculated according to the local short-circuit current level (where the surge arrester is installed). It must be equal to the cross-section of the installation s upstream cables. The minimum cross-section for the earth conductor is 4 mm 2 if there is not a lightning conductor and 0 mm 2 if there is a lightning conductor..74 Low Voltage Products & Systems

75 Application sheets OVR Surge Protection Devices Transient voltage surge suppressors Operating principle The Surge Protection Devices (TVSS), suitable for residential, commercial and industrial applications, are designed to limit transient overvoltage and run-off lightning currents. Application environments The Surge Protection Devices (TVSS) are necessary in any environment where the lightning risk exists (direct lightning strike / overvoltage). Example of installation As shown in the diagrams, one of the possible applications is to protect the equipment (TV, computer,...) against overvoltage thanks to a Surge Protection Device (TVSS) which ensures the protection in common mode (Ph-PE / N-PE) and differential mode (Ph-N). Type 2 TVSS Low Voltage Products & Systems.75

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077

ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 MINIATURE CIRCUIT BREAKERS ST 200 M data sheet System pro M compact miniature circuit breakers for supplementary protection acc. to UL 1077 The ST 200 M miniature circuit breaker provides supplementary

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

1492-SP Supplementary Protectors

1492-SP Supplementary Protectors Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Approval marks are easily visible on dome Terminal design helps prevent wiring misses Scratch-

More information

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors Close Protection from Moeller miniature branch circuit breakers miniature supplementary protectors FAZ branch circuit breakers General Information... Selection Tables Trip Characteristic C - Box terminals...

More information

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors . Miniature Circuit Breakers and Supplementary Protectors UL 077 DIN Rail Supplementary Protectors WMZS Circuit Breakers Contents Description WMZS Circuit Breaker Standards and Certifications................

More information

Jtec 10kA Miniature Circuit Breaker

Jtec 10kA Miniature Circuit Breaker Jtec 0kA Miniature Circuit Breaker EN 60898 The Jtec range has been enthusiastically adopted by a diverse range of customers seeking a cost effective 0kA performance. Jtec MCBs are available in a wide

More information

UL 489 DIN rail branch circuit breakers

UL 489 DIN rail branch circuit breakers UL 9 DI rail branch circuit breakers FAZ-A circuit breakers Product Overview UL 9 DI rail branch circuit breakers FAZ-A circuit breakers PRODUCT OVERVIEW Optimum and efficient protection Optimum product

More information

Miniature Circuit Breakers and Supplementary Protectors. Contents

Miniature Circuit Breakers and Supplementary Protectors. Contents . Optimum and Efficient Protection for Every Application Product Overview Features Optimum product quality, tested reliability and safety stand for best protection of personnel, installations and plant.

More information

Introduction Circuit Protection

Introduction Circuit Protection Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short

More information

9926 Series Branch Rated Circuit Breakers AC Version

9926 Series Branch Rated Circuit Breakers AC Version Branch Rated AC Version Hydraulic Magnetic Single pole and double pole versions 20/240 VAC, 50/60 Hz Up to 25A Just 3 mm wide Mounts on 35mm DIN-rail UL 489 listed, CSA C22.2 No. 5-02, CE VDE Ordering

More information

WMS SUPPLEMENTARY PROTECTORS

WMS SUPPLEMENTARY PROTECTORS WMS Supplementary Protectors Overview WMS SUPPLEMENTARY PROTECTORS Product Specification The WMS Supplementary Protector is a dual-rated product for both AC and DC supplies, in accordance with UL 1077

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

US BROCHURE. Circuit protection according to UL 489 and UL 1077

US BROCHURE. Circuit protection according to UL 489 and UL 1077 US BROCHURE Circuit protection according to UL 489 and UL 1077 2 CIRCUIT PROTECTION UL 489 AND UL 1077 CIRCUIT PROTECTION UL 489 AND UL 1077 3 Table of contents 004 006 Introduction 007 008 Product selction

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Product Guide. UL 1077 DIN Rail Supplementary Protectors

Product Guide. UL 1077 DIN Rail Supplementary Protectors Product Guide UL 0 DIN Rail Supplementary Protectors UL 0 DIN Rail Supplementary Protectors Product Overview... Product Selection WMZS B Curve ( X I n Current Rating)..............................................

More information

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application

OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) OTEC Miniature Circuit Breakers (MCB) Areas of Application Miniature Circuit Breakers Areas of Application Miniature circuit breakers (MCBs) of the N-System primarily protect cables and conductors against overload and short circuit. Thus, they also protect electrical

More information

UL 489 Cable-In / Cable-Out Branch Circuit Breaker

UL 489 Cable-In / Cable-Out Branch Circuit Breaker Product Overview UL 9 Cable-In / Cable-Out Branch Circuit Breaker PRODUCT OVERVIEW Optimum and Efficient Protection Features Complete range of UL 9 listed DIN rail mounted miniature circuit breakers up

More information

TeSys IEC Contactors and Overload Relays

TeSys IEC Contactors and Overload Relays TeSys IEC Contactors and Overload Relays Making High-Fault Short-Circuit Current Ratings Simple Schneider Electric is an industry leader in IEC contactors and overload relays, and is recognized as the

More information

Supplementary Circuit Protectors Type GSB63

Supplementary Circuit Protectors Type GSB63 Supplementary Circuit Protectors Type GSB63 l Protection of circuits against short circuit and overload currents l UL1077 supplementary protection l 1,, 3 and 4 pole arrangements l 13 amperage sizes up

More information

MULTI 9 System Catalog

MULTI 9 System Catalog MULTI 9 System Catalog Class 80 CONTENTS Page Schneider Electric Brands Section Introduction... Section UL Rated Protection Devices... Section IEC 097- Rated Protection Devices... Section IEC Rated Ground-fault

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Technical Data Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protectors Specifications Bulletin Number 1492, 1692 Topic Page 1489-M Miniature Circuit Breakers 1 1492-SP Supplementary Protectors

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Bulletin 1489 Circuit Breakers. Selection Guide

Bulletin 1489 Circuit Breakers. Selection Guide Bulletin 1489 s Selection Guide Overview/Description Bulletin 1489-A s Energy-limiting design protects downstream components better than conventional breakers during short circuits Field-mountable options

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 9 DIN Rail Miniature Circuit Breakers Product Overview................................................ Product Selection................................................ Accessories.....................................................

More information

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1

J7MN. Ordering Information. Motor Protection Circuit Breaker. Model Number Legend. MPCB system. Options. Motor Protection Circuit Breaker J7MN I-1 Motor Protection Circuit Breaker J7MN ) MPCB system Rotary and switch types Rated operational current 32 A, 63 A and 00 A Switching capacity up to 00 ka/400 V Fixed short-circuit release = 3 x I u Overload

More information

Multi 9 System Catalog

Multi 9 System Catalog Multi 9 System Catalog Catalog 0860CT00 R07/4 04 Class 860 CONTENTS CONTENTS Description............................................. Page Description Page Introduction..................................................7

More information

Selection Guide. Control Circuit and Load Protection

Selection Guide. Control Circuit and Load Protection Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

Allen-Bradley 1492-RCDA4A40

Allen-Bradley 1492-RCDA4A40 Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps

More information

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers .2 WMZ Circuit Breakers Contents Description WMZ Circuit Breaker Standards and Certifications.............. Selection................ Product Selection....................... Accessories...........................

More information

Control Circuit and Load Protection Products

Control Circuit and Load Protection Products Selection Guide Control Circuit and Load Protection Products Bulletin Numbers 188, 1489, 1492, 1692 Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka DATASHEET - FAZ-C16/1 Miniature circuit breaker (MCB), 16A, 1p, C-Char, AC Part no. FAZ-C16/1 Catalog No. 278561 Eaton Catalog No. FAZ-C16/1 EL-Nummer 0001695154 (Norway) Similar to illustration Delivery

More information

Protection Equipment

Protection Equipment Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Introduction Electronic Circuit Protection ESX10-T

Introduction Electronic Circuit Protection ESX10-T Introduction Electronic Circuit Protection ESX0-T Electronic circuit protection type ESX0-T is designed to ensure selective disconnection of 24VDC load systems. 24VDC power supplies, which are widely used

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) DATASHEET - FAZ-C10/2 Miniature circuit breaker (MCB), 10A, 2p, C-Char, AC Similar to illustration Part no. FAZ-C10/2 Catalog No. 278756 Eaton Catalog No. FAZ-C10/2 EL-Nummer 1695166 (Norway) Delivery

More information

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A DATASHEET - PKZM4-25 Delivery program Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection Part no. PKZM4-25 Catalog No. 222352 Eaton Catalog No. XTPR025DC1NL EL-Nummer 0004355158 (Norway)

More information

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60 DATASHEET - FAZ-C5/2-RT Miniature circuit breaker (MCB), 5A, 2p, C-Char, AC Part no. FAZ-C5/2-RT Catalog No. 102203 Eaton Catalog No. FAZ-C5/2-RT EL-Nummer 1691799 (Norway) Similar to illustration Delivery

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Supersedes June 2017 FAZ-NA-L FAZ-NA FAZ Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers three types of miniature circuit breakers for use in North

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

Product Guide. UL 489 DIN rail miniature circuit breakers

Product Guide. UL 489 DIN rail miniature circuit breakers Product Guide UL 489 DIN rail miniature circuit breakers UL 489 DIN rail miniature circuit breakers Product Overview................................................ 2 Product Selection WMZT 10 kaic at

More information

MULTI 9 System Catalog

MULTI 9 System Catalog MULTI 9 System Catalog Class 80 CONTENTS Schneider Electric Brands Description Page SectionIntroduction... Section UL 89 Listed Circuit Breakers and UL 77 Recognized SupplementaryProtectors... SectionIEC097-RatedProtectionDevices...

More information

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series

Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors. 101 Basic Series Learning Module 9: Miniature Circuit Breakers and Supplementary Protectors 101 Basic Series What You Will Learn We ll step through each of these topics in detail: Introduction 4 Miniature Circuit Breakers

More information

US Catalog July 2016 SMISSLINE TP

US Catalog July 2016 SMISSLINE TP US Catalog July 2016 SMISSLINE TP SMISSLINE TP modular bus system Table of contents Description 2 Building a SMISSLINE TP assembly for UL 489 and UL 508 based solutions Overview and ordering information

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100

Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 MAKING MODERN LIVING POSSIBLE Data sheet Circuit Breakers, Type CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit and overload protection of motor applications cover together with the circuit

More information

Applying branch circuit breakers and supplementary protectors in North America

Applying branch circuit breakers and supplementary protectors in North America Product Application AP01102005E WMZT WMZS Applying branch circuit breakers and supplementary protectors in North America Introduction Eaton offers two types of miniature circuit breakers for use in North

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers

More information

Thermal-Magnetic Circuit Breaker 2216-S

Thermal-Magnetic Circuit Breaker 2216-S Thermal-Magnetic Circuit Breaker 226-S Description One and two pole thermal-magnetic circuit breaker in compact design with slide actuator, trip-free mechanism, various trip characteristics and optional

More information

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2

The City of Winnipeg Dry Type Transformers up to 600 V Primary Section Bid Opportunity No Page 1 of 2 The City of Winnipeg Dry Type Transformers up to 600 V Primary Section 26121601 Bid Opportunity No. 1196-2014 Page 1 of 2 Part 1 General 1.1 RELATED REQUIREMENTS.1 Section 26 05 01 - Common Work Results

More information

Go to:

Go to: System PKZ 0 ectors 08/019 Clip plate Standard version Short version C-PKZ0 072900 C-PKZ0-K 206740 One of the clip plates is always necessary when combining a PKZM0 manual motor prr and a S(E)00 magnetic

More information

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control . Contents Description Relays and Timers......................... Miniature Controls......................... Contactors and Starters.................... Thermal Overload Relays.................... C440/XT

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

US CATALOG SMISSLINE TP

US CATALOG SMISSLINE TP US CATALOG SMISSLINE TP 2 SMISSLINE TP US CATALOG SMISSLINE TP US CATALOG 3 Table of contents 004 Description 005 012 for UL 508 and UL 489 based solutions Overview and ordering information 013 014 for

More information

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin 194R Fused and Non-Fused Disconnects Product Selection Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 1V 240V 240V 480V V 12V V Ref. Non-d 0 2 7. 1 A2 194R-0-NN 60 1 0 40 B2 194R-60-NN UL Class CC

More information

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400 Overcurrentswitch,10A,3p,C-Char,AC Partno. FAZ-C10/3 Articleno. 278869 CatalogNo. FAZ-C10/3 Similar to illustration Deliveryprogramme Product range FAZ Application Instantaneous release response current

More information

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin 194R Fused and Non-Fused Disconnects Product Selection Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class

More information

Miniature Circuit Breakers for Railway Applications

Miniature Circuit Breakers for Railway Applications Siemens AG 00 for Railway Applications BETA Low-Voltage Circuit Protection The miniature circuit breakers are used in fixed railway systems and rolling stock for protecting system components against overcurrent

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

For Sales and Support call KMParts.com (866)

For Sales and Support call KMParts.com (866) Overcurrentswitch,5A,1p,B-Char,AC Partno. FAZ-B5/1 Articleno. 278528 CatalogNo. FAZ-B5/1 Similar to illustration Deliveryprogram Basic function Miniature circuit breakers Number of poles 1 pole Tripping

More information

DSE201, DSE201 M Compact design with enhanced protection

DSE201, DSE201 M Compact design with enhanced protection DSE20, DSE20 M Compact design with enhanced protection Ultimate safety DSE20 and DSE20 M: the highest level of reliability The P+N electronic residual current circuit-breakers with overcurrent protection

More information

Overvoltage Protection

Overvoltage Protection Overvoltage Protection Weidmuller has a complete line of overvoltage protection devices to effectively stop the harmful effects of electrical overvoltage and electrical noise. There is strong potential

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and

More information

Circuit and Surge Protection Protection Solutions Catalog. North America

Circuit and Surge Protection Protection Solutions Catalog. North America Circuit and Surge Protection Protection Solutions Catalog rth America Contents Circuit and Surge Protection Branch Rated and Supplementary Circuit Protection Introduction 3 BR Series - AC 277/480V rated

More information

Time Delay Values (E-Series)

Time Delay Values (E-Series) Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short

More information

MOTOR PROTECTION CIRCUIT BREAKERS

MOTOR PROTECTION CIRCUIT BREAKERS MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications.

Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC. Application Switchgear for industrial and advanced commercial applications. Miniaturecircuitbreaker(MCB),16A,3p,B-Char,AC Similar to illustration Partno. FAZ-B16/3 CatalogNo. 278847 EatonCatalogNo. FAZ-B16/3 EL-Nummer 1695123 Deliveryprogram Basic function Miniature circuit-breakers

More information

Solid-State Switching Devices

Solid-State Switching Devices Overview 3RF21 3RF20 3RF22 3RF23 SIRIUS 3RF2 solid-state switching devices Solid-state switching devices for resistive loads Solid-state relays Solid-state contactors Function modules Solid-state switching

More information

PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:

More information

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules. Motor Protection Circuit Breaker (MPCB) J7MN MPCB system (motor protection CLSS 0) Rotary and switch types Rated operational current = 2, 25, 50 and 00 Switching capacity up to 2.5 = 00 k/400 V Fixed short-circuit

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

CERTIFICATE OF COMPLIANCE

CERTIFICATE OF COMPLIANCE Issued to: SIEMENS AG LOW VOLTAGE SIEMENSSTRASSE 10 93055 REGENSBURG GERMANY This is to certify that representative samples of CIRCUIT BREAKERS, MOLDED CASE AND CIRCUIT- BREAKER ENCLOSURES See Addendum

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Non-Fusible Disconnect Switches

Non-Fusible Disconnect Switches UL 98 and IEC, Non-Fused Switches Mersen s non-fusible disconnect switches are listed to UL 98 and bear the CE mark as conformance to IEC 60947-3. They are service entrance devices that are capable of

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA

454 PHOENIX CONTACT Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 454 PHOENIX CONTACT and feed-through terminal blocks The more varied the tasks in electrical engineering, the more varied the components for the solution have to be. The industrial connection technology

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

Motor protection circuit breakers

Motor protection circuit breakers Wide adjustment range 0. to 00A IEC breaking capacity Icu 50kA (400V) up to 00A Suitable for isolation Comprehensive line of accessories Magnetic-only version Automatic trip indicators High reliability

More information

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information... Ice Cube Relays R2/R4 Plug-in Power Relays... 58 Technical Information... 63 R15 Plug-in Power Relays... 68 Technical Information... 72 RUC Plug-in Power Relays... 76 Technical Information... 79 RY2 Plug-in

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors 6/4 Introduction 6/5 5TE8 control switches 6/7 5TE4 8 pushbuttons 6/9 5TE8 On/Off switches 4 6/11 5TE1 switch disconnectors 6 6/1 Switch to manual? Wherever electrical systems need to be switched on or

More information

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration

More information